Loading...
HomeMy WebLinkAbout51344-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51344 Date: 11/04/2024 Permission is hereby granted to: Stephen Wiseman 1 Beverly Rd Bronxville, NY 10708 To: Construct an accessory in-ground pool/hot tub combination to an existing single-family dwelling as applied for per ZBA De Minimus approval. Premises Located at: 8581 New Suffolk Ave, Cutchogue, NY 11935 SCTM# 116.-1-1.2 Pursuant to application dated 09/17/2024 and approved by the Building Inspector.. To expire on 11/04/2026. Contractors: Required Inspections: Fees: SWIMMING POOLS-IN-GROUND WITH FENCE ENCLOSURE $300.00 CO Swimming Pool $100.00 Total $400.00 Building Inspector �yfF CIO 7. TOWN OF SOUTHOLD-BUILDING DEPARTMENT "w Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 • '` Telephone(631) 765-1802 Fax(631)765-95021a : �www.southoldtgw . o Date Received APPLICATION FOR BUILDING PERMIT For Y D . PERMIT NO. Building Inspector. ,.5 �, ,� P I » Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an ]EIT"MIDING MITT. Owners Authorization fm n (Page t)shall be completed. TOW 1 °IF SOTJ711f�'l Date: OWNERS)OF PROPERTY: t Name: due t S@ ,SCr'i SCTM#1000- U 1 - 1. U d '., Project Address- I o c'�* e . Phone#: q1q Email: Mailing Address: J A Pw 6 r e . i4 e �. NTACT PE N: Name: Mailing Address: p Phone#: 6 f SEmail: DESIGN PROFESSIONAL INFORMATION: Name: C 0 11 C/-0 S_S CC. Mailing Address: Phone#: (e 31 5 S3 - D 115) -e5�q AV' CONTRACTOR INFORMATION: Name: mt�- a/S r �?� t. Mailing Address J Phone#: .7& S-G Email: �S[Ot�rr� -4"D4 41615 0 . ✓�ra�r"�i DESCRIPTION OF PROPOSED CONSTRUCTION Repair ❑Demolition Estimated Cost of Project: ❑New Structure ❑Addit�o Alteration u��r Other �" w^�*n %90 Gn 0 � Will the lot be re-graded? Yes ❑No Will excess fill be removed from premises? ❑Yes 1KNo PROPERTY INFORMATION Existing use of property: e-- Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? DYes El No IF YES,PROVIDE A COPY. 0CheckBoxAfterPleading: ibe owner/wnuador/ Is foss and St0npvmtw hviesas: dedlby Chapter26 of the lion C%le.APPUCA11M f5 mftESlr fVfAf1d:to ft'bulMdfrg fay the Issuance of a SaFfdf to the charm of the Town of 010,Suffollk,Countv,New York wW oar apokable,tows.VaRnmwes of ROW110"Ons,for,the cousbmcdon of addirtlem,aftwatlom or fer yerrmoall or demalfflon°as hinvin d The appkard agrees to tom*With all applimWe knowso ardinances,bulldire co*, hotising code arwd regublims and to#do audwrked hupeam on:prentises wW In feu dh�ds)ftw McesMY 10SPedi0m False stems made herein are punhihabMa as a Cass A adscleateanor pursuant to Sectkm 2.10A r of the New York SMe Pew Law. Application Submitted By(print name): -4 (MAuthorized Agent ❑Owner Signature of Applicant: Date: /�Z 12y CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State of New York SS: No.01BU616a0 0 Qualified In Suffolk County G COUNTY OF_ ) Commission Expires April 14,2 ��o being duly sworn,deposes and says that(s)he is the applicant (Name of indivri al signing contract)above named, (S)he is the I-U t f (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ,+ 4 V l 20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 PROPERTY INFORMATION Existing use of property:residential Intended use of property:reSidentall Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Not flood zone; Southold School district this property? ❑Yes 5ANo IF YES,PROVIDE A COPY. I@ Check Box After Reading: The o rrneri Idesign professional Is responsible for all drainage and storm water issues as provided by Chapter 2M of the Torn Lode.APPLICATION IS HEREBY FADE to the i Department for the issue of a Building Pen>hR pursuant to the Building zone Ordinance of the Torun of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to an.ply with all applicable laws,ordinances,build n code, housing cozfa arwd'regulations and to admit authorized inspectors on premises and in buildings)for necessary 6hspection&False statenhents made herein are punishabk C Ins A misdemeanor pursuant to Section 210AS of the New York State Penal law. Martin Ford (Island Gunite Pools) Application Subr4t teed By(print name): MAuthorized Agent ❑Owner g anti�� Signature lice Date: STATE OF NEW YORK) `'� SS: COUNTY OF ) „ being duly sworn,deposes and says that(s)he is the applicant Name of individual signing contract above n' ( g g ) ed, (S)he is the (Contractor,Agent, rporate Officer,etc.) of said owner or owners,and is duly authorized to perform o ave performed the said work and to make and file this application;that all statements contained in this application are to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the applic 'can file therewith. Sworn before me this day of 20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) Susan Wiseman residing at 8581 New Suffolk Avenue, Cutchogue I, New York, 11935 Martin Ford (Island Gunite Pools) do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. ' September 14, 2024 Owner's Signature Date Susan Wiseman Print Owner's Name 2 Scott A. Russell SUPERVISOR AM[A\N A\G]EN\11E-IF SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town oW n of So u th o l d CHAPTER 236 - STORMWATER MANAGEMENT REFERRAL FORM PLICANT INFORMATION TO BE COMPLETED BY THE APPLICANT nib ROPERTIES ONLY FOR P ONE ACRE IN AREA OR LARGER. ) �p sr APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) mo 5 ° NAME:. �� �' ��—� �� .. _�. Date: 7-L Contact Information: ._ (I:-Mail R I'elephnne Numheil �' Pro ert Address / Location of Construction Site: I�. _.. Dutric eL. S.C.T.M. # 1000 LA I, Z ......�. ... __...� ........�. _.... _... _.�. _ w �..._......... Section Block Lot TO BE COMPLETED BY SOUTHOLD TOWN ENGINEERING DEPARTMENT - Area of Disturbance is less than I Acre. No S P D E.S Permit is Required ! - rge to Waters of the State. No S.P.D.E,S. Permit is Required Project does Not Discharge ! - Area of Disturbance is Greater than I Acre & Storm-water Runoff Discharges Directly to Waters of the State of New York, THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit DIRECTLY From N.Y.S. D.E.0 Prior to Issuance of a Building Permit. ,1rca of Disturbance is Greater than I Acre Storm-\.\arPr Rimoff Flows Through Southold Town's MS4 Systems to Waters of the State of Ne�\ York, THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit through the Southold Town En., ineeri Department Prior to Issuance of a Building Permit.. Rev ievv ed By: Date: _ m FnR ivr * cvrrp-Tnc n,-rni,PT ?n 1 n � tcefi' ve4 qb /R`� Client#:12643 ISLAGUNI DATE(MMOWYWY) ACORD. CERTIFICATE OF LIABILITY INSURANCE 9/10/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. _ ONAL INSURED s or be If IMPORTANT:BR GATION S WAIV D,subject to the r is an Dtermsand conditiNAL on the certainave require an endorsement A statement and this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: Commercial Support ewood Partners ins.Center IT Per: 9790 �9 cR�639390�700—�.... .... — � i�.631 390 .. . ._....._ 40 Marcus Drive %D ss; NEcertificates@epicbrokers.com 3rd Floor AR ,sw �_ ... _ INSURER(S)AFF11#Cr'CO'YERr4GE NAIC>I 11 Melville,NY 11747 R A®Hartford FeeInsurance .s"__.__ INSURIE.,, . __.. ply e, ..� nce Corn 19682 _NS_.� � URER B.Hartford Casual Insurance Company INSURED and Gumte Swimming Pool,Inc IN URERC. P rty C'a 24 Prr a asualty Ins Co of Hartford ..... 34690 PO BOX 1595 WSURER D.Trumbull insurance . _... urance Company ......... 27^l20 Sag Harbor,NY 11963 _ ... INSURER E ...... INSURER F a'. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE 114SURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES_ LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. Low INeR TYPEOFIwasarRANCE ...' � s 12UUNOZ9418 � m 26A2023 fl 61202 s wA "X, 1JAelurr -r RENrE $300000 0 coMMERcwLSENExAL„ AMA � . EACH OCCURRENCE $1 000 .._.. CLAIMS-AAADE X OCCUR r+RPAvIB°a X Contractual Liab. "N 5 0. _..� _....... MED E�,'P C�,o4euW orn��'..,.,., ..,..,. ,� .�. PERSONAL&ADV IN IURY,_._ s1,0001N mmmm ENI-AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE $ _000,1IOII m �� PRO- PRODUCTS COMP10P AGG 2,000 000 POtlCY I ^I dECT LOC OTHER: $ p AU1 RITY 12UENO29833 912 20231091261202 --X ANY AUTO .. ......_ l �`�") $ BODILY INJURY 'OWNED SCHEDULED INJURY(Per�.chdi�tvl') S ,.,.^. ..............._,_. AUTOS ONLY AUTOS - BODILY Y DA1dAPZE X HIRED NON-OWNED $ AUTOS ONLY X AUTOS ONLY P�CNPER'�-..I B ExcEss uMeR�e Lu►e FOCC—r-LA1MS4=E 12HHUOZ9419 9126 202 cc 09 26J20 AGGRE ATo .. �1, ,Lu►e _ � ��000�Q00__ c ,WO D� �}l� ETrTc aslCd i O 12WEQD9B24.m_._ 9/2�02 09..,. _ _ _...... woR�Rs COMPENSATION 126J202 X OR AND EMPLOVERs,unsairY 5:EL EACH A ANY PROPRIETOfOPA'RTNERSXECUTtVE YIN E.L DISEASES-EA k',MPC,C9YCE 1 's000 OFFICER EMBEREXCLUOED1 Y� NIA _ S1,000, 10000 (M�a�ra In NH) .m.. .._m._.._a ..00. IDI eS.C. Rd.mme11.s"Te�nIO.b,eN.._under .... ..�.. .___ w ._........___ ..__ EiDLseass-PO POLICY LIMIT ._S.TONS below IT _ EMCFUKWIJOFOMaUnONSILOCATONSIVHiICIFS r 1 I.nO IImmO r0.0...0w. ....., {ACORD 101,AddWortal Remarks Sc may be attadwd'R mole space is toquirerl) CERTIFICATE HOLDER CANCELLATION Town Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCEL L BEFORE ED BORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN PO Box 1179 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATME; ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016103) 1 of 1 The ACORD name and logo are registered marks of ACORD #S6895986IM5934308 NVF-02 Client#:12M ISLAGUNI ACORD. CERTIFICATE OF LIABILITY INSURANCE ["DATE 9/10/201CY20DIYYYY) 24 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED R PRODUCER,AND THE CERTIFICATE HOLDER. l�ORT NM If theE O rh0 to holder s a ADDITIONAL INSURED,he policypes)'must have ADDITIONAL INSURED provisions or bendorsed. �_.� be endorsed. if SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer any rights to the certificate holder in lieu of such endor'sementfs). i.cEdgewood Partners Ins.Center Ho" T063-390�700 0 r l 6 NA Pp �J IAI�C��iw Exl}_ .�. . 31-390 9790 40 Marcus Drive E nAIL NBcertific to icbrokers corn 3rd Floor INsusI ArF �^m �M Melville,NY 11747 INSURER Hartford Fire Insurance Company, � covERA 19682 INSURER B:Island Gurute Swim _ Ha ., mpany 29424 m_ INBkIRER c INSURED 34690 ��Cas� Ins Co of Hartford.—. Insurance _ Swimming Pool,Inc. — .. ..._. 27120 ,. PO BOX 1595 g Trumbull Insurance Company Sag Harbor,NY 11963 INs URER E� _.......... ................ m �._.. . — INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, .___ .. CLAIMS- .........OF SUCH POLICIES. SHOWN HAVE BEEN REDUCED BY PAID C IlasR EXCLUSIONScoxllcuu cerlRaL CONDITIONS OF w �4189126/ .i. rrYS- - LTFk _""" )NS'(~m !YYYIb LIMITS ��...._ ......... ADDI In A X F,U R,EN CE 1 000 000 cuuMs�IADE occuR 12UU O O24 09126P202a one Nrsun)v $5000000 Contractual Liab. - PERSONAL&ADV,,.INJURY,,,,,_,,,,,,, GEN'L AGGREGATE LIMIT APPLIES S PER. "GENERAL ��'�� AL°rGREOATL_ ��,21„ _ m_....., __. IOPAGG 2�t10O Otlli PROD'LP1;•"H` COMP OG �1 000 0 El OTHER .....�...�._..�. .. . .... POLICY X JECT ,�..m,. L..,..,_.�.._ .... � .....___ ,... ...�,�._. �_... .� ..,._...,.,... ,.,.. ^— ,_mmCOM13G1NED'�INGLE'.LI�hICT D lEo cadehl_,.— .,... ..._ 51... 00 ....._ AUrO'MOBILE�LIABILI Y 12UENOZ9833 9)26)2024 091261202 ,.. ANY AUTO BODILY INJURY(Per person) $ .._._.�..._,.... .�., ,_. ,,,.� .,..... .... OWNED SCHEDULED BODILY)NARY(Per acdder'd) S AUTOS ONLY X... NON-0WNED PROPR.F"�'IYDAMAGE� AUTOS ONLYAUTOS HIRED AUTOS ONLY .(Per uwxe#(wR) ., B - X occuR - w..... ...w.� ...._n._ �.__ �....� _. aa� suc _ w�. ALIAB 000 12HHUOZ9419 019126120241091261202, EXCEMSSLIAB cn. Il�ls lwarr�r s WORKERS R N Ns10 0 12WEQD9B24 . .. 9126120 1 -- ._ CO24 09126N202 XT�iTF AtC41SI _ YIN 1 0OO OOO AND EMPLOYERS LIABILITY ... AN'YPROPRi'ETO�RMARTCVERIEXE'CUTI'"J'F S Of FICERWMEMBER EXCLUDED? ��� NIA E L I ACII NN� DISC (MandalelY In NH) .. m If Yam,describe ttcudarr _ ....._ , s1 000 000 ...,.�.. ._.... ...... . .... _...... EJ_DISEASE POLICY LIMTT.,..�I. _A'.,.m .. ...w.._. DESCRIPTION OF Op'ERATIONSI LOCATIONS I VEHICLES(ACORD 109.Ad&t Renwks Schodufo,nW be hed if mmespar.e is requeed) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE DEScJdBED �WILL BE CANCELLED EAD�BERE PO Box 1179 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 - AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016103) 1 Of 1 The ACORD name and logo are registered marks of ACORD #S6895988IM6895967 NVE02 y-1 BOARD MEMBERS �+', Southold Town Hall Leslie Kanes Weisman,Chairperson 53095 Main Road•P.O.Box 1179 Southold,NY 11971-0959 Patricia Acampora fficem Location: Eric Dantes Town Annex/First Floor, Robert Lehnert,Jr. 54375 Main Road(at Youngs Avenue) Nicholas Planamento Southold,NY 11971 http://southoldtownny.gov ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel. (631)765-1809 July 25, 2024 Stephan and Susan Wiseman 1 Beverly Road Bronxville,NY 10708 Re. De Minimus Request, File#5138 Brush/Wiseman, 8581 New Suffolk Avenue, Cutchogue SCTM No. 1000-116-1-1.2 Dear Mr. and Mrs. Wiseman; We are in receipt of your correspondence, received July 15,2024, requesting a de minimus approval related to ZBA determination#5138, dated July 25,2002, in which variance relief was granted to construct an in-ground swimming pool,upon the above re ferenced premises. In your letter,you described your meeting with the Southold Town Board of Trustees and your discussion with them about relocating the swimming pool more than 100 feet landward of the wetlands, which would place the pool outside of Board of Trustee's jurisdiction. In this proposed location, the pool will continue to be located in the side yard of the property. I have reviewed your request, the hand drawn edits to a survey that you provided, and have determined that the relocation of the swimming pool as depicted, is de minimus in nature. Please provide this Board with two (2)original updated signed and sealed surveys of the proposed change, and contact our office if you have any further questions. 7Ka nes Weisman, Chairperson cc: Building Department 0 Southold Town Hall Received 53095 Main Road P.O. Box 1179 JUL 18 2024 Southold, New York 11971-0959 Attention: Leslie Kanes-Weisman, Chairperson Zoning Board„of Appeals And the Zoning Board of Appeals By email Ladies and Gentlemen, We are writing to you in connection with a�d �emini i`s_updaW to a variance that was granted on a property that we are purchasing at1861 New Suffolk Avenue, Cutchogue. The variance that was granted in 2002 is attached to this letter and was a variance for a 20 x 40 pool to be located in the side yard of the residence at a distance of 85 feet from the wetlands that are behind the house. At the time the variance was granted, the Trustees also granted a permit to install the pool; however, that permit expired after two years, while the variance granted by the Zoning Board remains in effect. The de minimis changes that we would like to make are as follows: we would first like to situate the pool further away from the wetlands by placing the pool at approximately the midpoint of the center of the side of the house, more than 100 feet from the wetlands, which would situate the pool completely in our side yard (see attached proposed mock-up). We also would like to install a small, five-by-five foot hot tub in the pool, thus increasing its length by five feet(20 x 45 instead of 20 x 40). We met with the Trustees on July 9th and discussed our thoughts with them about relocating the pool landward of the wetlands, which was met with a favorable response, as they encouraged us to place the pool outside their jurisdiction. We are excited to become members of the Southold community and look forward to many years in our new home. Please let us know if you require additional information for us to make these small changes to the approved permit, and thank you in advance for your consideration. Sincere your Step en and Susan Wiseman APPEALS BOARD MEMBERS � [ » Southold Town Hall Gerard P. Goehringer, Chairman ' ` 53095 Main Road Lydia A.Tortora P.O. Box 1179 George Horning Southold,New York 11971-0959 Ruth D. Oliva ZBA Fax(631)765-9064 Vincent Orlando "�►► Telephone(631)765-1809 http://southoldtown.nOTthfork.net BOARD OF APPEALS TOWN OF SOUTHOLD FINDINGS,DELIBERATIONS AND DETERMINATION MEETING OF JULY 25,2002 Appl.No. 5138-NANCY BRUSH Property Location:8581 New Suffolk Avenue,Cutchogue CTM#116-1-1.2 SE RA DE A I N: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without an adverse effect on the environment if the project is implemented as planned as a setback or lot line request. ROPERTY FACT / PTI Nl: The applicant's property is located on the easterly side of a private right-of-way which extends north from New Suffolk Avenue in Cutchogue. This lot is shown as Lot 3 on the Minor Subdivision Map of Winds Way with a total lot area of 2.46 acres (upland and marsh areas). The lot is improved with a 1-1/2 story frame house with deck as shown on the survey prepared by Roderick VanTuyl, P.C. dated October 4, 1994,last amended June 7,1995. BASIS OF APPLICATION: Building Department's April 1, 2002 Notice of Disapproval denying a permit to construct an accessory swimming pool on the grounds that the pool is proposed partly in a side yard instead of the required rear yard,provided under Zoning Code Section 100-33. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on July 25, 2002, at which time written and oral evidence was presented. Based upon all testimony, documentation, personal inspection of the property and the area, and other evidence, the Zoning Board finds the following facts to be true and relevant. AREA VARIANCE RELIEF REQUESTED: Applicants request a location of an accessory 20' x 40' in-ground swimming pool behind the house, in the south yard area, with setbacks of 85 feet from the westerly lot line and approximately 115 feet from the easterly(rear yard)line at its closest point. REASONS FOR BOARD ACTION: Based on the testimony and record before the Board and personal inspection,the Board made the following findings: 1. Grant of the area variance will not produce an undesirable change in the character of the neighborhood or detriment to nearby properties. The property is a large wooded lot. The topography of the land consists of marsh land and restricted non-building areas, regulated under the wetland ordinances by other agencies. Applicant is proposing placement of the pool in an area that is best suited since this area is more level and provides a buffer between the structure and woodland adjacent to the marsh on this 2.6 acre lot. 2. The benefit sought by the applicant cannot be achieved by some method, possible for the applicant to pursue, other than an area variance. There is a steep slope from the residence to the meadow land in the rear yard, a conforming area, which makes it difficult to locate a pool. In addition, the . ....... ........�. Page 2—July 25, 2002 ZBA Appl. No. 5138—Nancy Brush Parcel 116.-1-1.2 at Cutchogue applicant's have tried to maximize the distance between the pool and the meadow lands to mitigate potential impacts to the environment. 3. The variance granted herein is not substantial in relation to the code's required rear yard location because only part of the in-ground pool will be located in the side yard. A major part of this pool structure is behind the dwelling,at the south side of the site. 4. The alleged difficulty has been self-created and is due to the applicant's desire to enjoy an in-ground swimming pool. 5. No evidence has been submitted to suggest that the proposed additions will have an adverse impact on physical or environmental conditions in the neighborhood. The variance granted is not substantial. A:major part of this pool structure is behind the dwelling,at the south side of the site. 6. Grant of the requested variance is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of anin-ground swimming pool while preserving and protecting the character of the neighborhood and the health,safety and welfare of the community. BOARD RESOLLUTION: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Chairman Goehringer, seconded by Member Orlando,it was RESOLVED, to GRANT the variance, as applied for in accordance with the pool location shown on the survey prepared by Roderick VanTuyl, P.C. dated October 4, 1994, last amended July 7, 1"S. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. VOTE OF THE BOARD: AYES: Members Goehringer(C Tortor g, d Or do. (Absent was Member Oliva.) This Resolution was duly pted(4-0). , GG e ec, ai n "Jt CEIVED AND FILED BY T1_1E SOUTLIULD TOIN114 CLEilK I�: IZS TOWU Clerk, TC; 1I al_®_ S 1 2 3 4 r Deck Shotcrete Shall Conform Spa Side O Elev.0.0 O O Autofill-�� To ACI 3184.2.2 Remote lJ Walls Shall Bear On Soils Coping r=� r t-'' With a Minimum Bearing nr ,. ---12"--- eck Capacity of 2,000 Ibs/SF. Bench /I\ /I\ /I\ UnderwaterSkirr(&r The Presumptive Soil M Water LiSpaH drothera LED Pool Light T Conditions Shall Be In +H Y pY ( Yp. of 3)Mad T of 8 (Typ. of 4) Compliance Per Table( Yp ) Float R401It is a.Basis of the Desi n Frost-Proof Spa Light----. 6' Rope That Soils are Classified Tile at Water Line 10 '11 A SW,SP,Sm,SC,GM or Pit Steel Shall Be GC. If Rated as Silt or 12"Wide Common 1/2"Marcite B-B Wall 1/2"Above #4 @ 10"O.C.E.W. Clay, Notify Designer With ,� 8 /� Tie To Pool Shell @ Actual Bearing Capacity Finish Section 7 Water Level @ 10"O.C.,24"Min. Before Constructing Pool. Embedment Spa Chalnnel DrockalAe ins 3'-9"to 8'-3' Deck Return (3 Ports) I*#4 Bars Elev.0.0 1 @ 1'Otal. 18' ars tA-A A A i*@6BOC. Section 6' 8" Vertical Section •. , 6" Radius -PneumaticallSteel-Tex Sun 11 Auto Cover Shelf Steps Pit' a d I Applied Concrete ° I (Shotcrete,4,500 psi, min.) 45 24"Wide Blue 6"to 8"of Pool Steel Notes Stone Coping 2'-0"Min. Lap Gravel Minimum Steel Cover Rquirements Over Cover Box *Note: To Soil:3 Inches tep of 5) OCEW in Middle of 8"Slab Floor Steel#4 Bars @ 12' To Pool Water:3 Inches (Typ. o Pool Return Provide, Install&Shoot Pool& S 4 t t ? t Spa Against Steel-Tex. �51 Pool Wall Section All Reinforcing Steel to be N.T.S. Contiuous& Bonded Per Coping Deck Shoot Autocover Box Code B ) Proposed Swimming Pool/Spa Layout Elev.0.0 Integral With the Pool Scale: 1/4"= 1' Shell B Auto Cover Recessed Coping Deck/Pool Coping 45' Gunite Box.Size Per Stone Elevation Inside Pool Face Cover Manufacturer 1 #4 Bars at Skimmer Water Level Top of Coping 6 6"Frost Specifications Deck Each tep Mouth (Typ.) (El.-3" Stone Proof Tile Deck Level 6"x 6"Frost-Proof Tile at Water Line Lev - ----- ------------- LED Light #4 Bars 17' a' (Typ.of 4) O.C.E.W. . r---i 1/2"Marcite I • 3'-6' 1/2"Thick Finish Attach Wall Marcite Finish Cover Box 21" 12„ Steel to 1 Drain to Dry Pool Steel 12 Min. Well a ' �1 Slope Break Point Per 8 Tie Cover Box Steel a' Owner& Local Code To Pool Shell Steel z a #4 Rebars Bars P o ' P P Radius 16 @ 12"O.C. Tied To Steel Cage 6"to 8"of 3 Min. 1 ° Provide Four Additional Hydrostatic Gravel Slope Break Point Per P Owner& Local Code II **#4 Bars Valves If Record High Groundwater d II @ 12'O.C. Is Within Three (3) Feet Of Deep End P 4 Vertical II e a'Cover OvverdSteel, Minimum Pool Slab Bottom. a ° 4 II ° d 11' 17' P O O P O II ° II **#4 Bars ° II @ 12'O.C. Horizontal 9' g' ..'4 If- Pneumatically C Main Drain W/ Applied Concrete 2 Pool/Spa Section A-A Hydrostatic Valves& (Shotcrete,4,500 psi) C Collector Tubes In Gravel ��� ° „ -1 Scale: 1/4"= 1' 6 �� Radius Interior Walls 1/4 a Level 7' Above Normal =�_' Unblockable Deck Inside Spa Face Water Level a ° a Channel Drain Level ° 8„ Spa Skimmer • e 2'Min. La a 4� Ok Automation Panel Q Attach Bottom 6"to 8"of All Reinforcing Steel to be Wall Connected to Pumps & Steel To Pool Gravel Contiuous & Bonded Per Pool Inlet Actuator Valves Q• 14 Steel Code Pool Spa Wall Section **Note: Suction �-1 ca e: T�. Floor h Way# Rebariddle of 8'1'Slab C. � 6"to 8"of Gravel Provide Gas Fired Pool Heater Equipped With Controls Filter °' 3 Spa Section B-B That Meet the Requirements of the State of New York,2015 Suction I c P - Scale: 1/4"= 1' IECC With 1026 Energy Code Suppliment. o I Sump All Steel to be Electrically Bonded In Accordance 0 With NEC and Local Requirements. Strainer Recirculation This Pool Is Not Designed to Accommodate Pump Filter a Diving Board Now or In the Future. Plans Prepared Only For Layout&Shell Steel Installing a Diving Board On This Pool Special Structural Note Is Hazardous and Will Cause Personal Injury - or Death. R&W Engineers, P.C. makes no representation that the in-situ soils are suitable to support the swimming pool on grade. A qualified D 3 Way Check To Dry The Design and Construction Shall Comply geotechnical engineer shall be consulted in this regard and the Actuator Valve Well With the Requirements of the 2020 NYS Residential project progressed per their recommendations. Groundwater is [) Code and NSPA Standard 70,2017 NEC. assumed to be at least two feet below the maximum excavation. Valve D Well to Be 8'Diameter Operation Dry A soil boring was not provided. Pool Mode:Suction 100%From Pool Pool Wall Chlorinator By 4' Deep, Wrapped With Panel 400 000 BTU Filter Fabric. Min.3'of Prepared For Larry A. S Return: 75%to Pool;25%toS a Return � ►Y ,. �_ ��• R & W / Engineers P.C. p Propane Good Draining Material A" r 380Townline Road,Suite 50,Hauppauge, Tub Mode:Suction 100%From Spa Around &Below Dry Well. Island Gunite �'s a� 1,o_E•1 F;� �, ppauge,NY 1 va8 Return: 100%to Spa Heater Swimming Pools, Inc. Phone(631)969-8535 Fax(631)969-8518 3 Way Actuator < -' Valve LJf°` � z Wiseman Residence ;v 8581 New Suffolk Avenue Spa Wall GUNITE SWIMMING POOLS Return t Cuthogue, NY 11935 Filtration System Schematic Chlorinator P.O.Box1595 QA wg. o.- ContractDr to Provide the Homeowner a Set of Sag Harbor,N.Y.11963 n �� Proposed Swimming Pool & Spa -1 N.T.S. All Equipment Manuals& Have the Homeowner Tel.(631)725-2721 cFfSS1 S_ Sign an Affidavit Acknowledging Receipt of Same. Fax.(631)725-4661 Dwg.Scale Designed By: Date: of E-Mail:IslandGunitePools@GMal.com Llc. No.: 68956 As Noted ILAR Sept. 13,2024 2 2 T 3 4 2 3 F 4 R326 Swimming Pools,Spas and Hot Tubs R326.4.2.4 Widely Spaced Horizontal Members.Where the barrier is composed of R326.7.2 Alarm Activation Pool alarms shall activate upon detecting entry into the water R326.3.1 The provisions of this section shall control the design and construction as well as horizontal and vertical members and the distance between the tops of the and shall sound poolside and inside the dwelling. substantial modification of swimming pools,spas and hot tubs installed in or on the lot horizontal members is 45 inches or more, spacing between vertical members shall R326.7.3 Prohibited Alarms The use of personal immersion alarms shall not be construed as of dwellings regulated under this code. Detached on and two-family dwellings not be greater than 4 inches. Where there are decorative cutouts within vertical compliance with this section. classified as Group R-3 are constructed under the Building Code of New York State. members,spacing within the cutouts shall not be greater than 1-3/4 inches in width. General Pool Notes Exception: Communal pools for the shared use of multiple townhouse units shall be regulated R326.4.2.5 Chain Link Dimensions. Maximum mesh size for chain link fences shall be a by the Building Code of New York State. 2-1/4 inch square unless the fence has vertical slats fastened at the top or bottom 1. The design is based on a drainable soil with less than 10%silt. Groundwater shall R326.1.1 Compliance with other sections. Swimming pools,spas and hot tubs shall comply with which reduces the openings to not more than 1-3/4 inches, not exist within the limits of the excavation. If groundwater is encountered within this section and other applicable sections of this code. The requirements of this section R326.4.2.6 Diagonal Members.Where the barrier is composed of diagonal members, two (2) feet of the pool bottom, special dewatering facilities will be required. and of the other applicable sections of this code shall be in addition to,and not in the maximum opening formed by the diagonal members shall not be greater than 2. No surchrge is permitted within four (4) feet of shallow end and six (6) feet of the A replacement of or substitution for, the requirements of other applicable federal,state 1-3/4 inches. deep end of the pool. and local laws and regulations, including, but not necessarily limited to the requirements R326.4.2.7 Gates. Gates shall comply with the requirements ofSections R326.4.2.1 3. The pneumatically applied concrete (gunite) shall be a 1:4 mix with a minimum A of Section 8003 (Federal swimming pool and spa drain cover standard) of Title 15 of the through R326.4.2.6, and with the following requirements: of 3-1/2 gallons of water per sack of cement. United States Code (CPSC 15 USC 8003),where applicable. R326.4.2.7.1 Self-closing and Opening Configuration.All gates shall be self-closing. 4. Reinforcing steel shall be intermediate grade billet steel with a minimum lap of R326.2 Definitions. For the purpose of these regulations, the terms used shall be defined as follows In addition, if the gate is a pedestrian access gate,the gate shall open outward, 24 inches for#4 bars. and as set forth in Chapter 2. away from the pool. 5. Corner radii shall be a minimum of 12 inches, unless noted otherwise on the plans. Barrier, Permanent. A fence, the walls of a permanent structure,any other structure or R326.4.2.7.2 Latching.All gates shall be self-latching,with tie latch handle located 6. A minimum of four hydro-static relief valves shall be appropriately located in the combination thereof which completely surrounds the swimming within the enclosure i e o p y g pool and sufficiently obstructs (�:•., n the pool side of the enclosure) and at least 40 inches pool bottom. access to the swimming pool. above grade. In addition, if the latch handle is located le>s than 54 inches from 7. Provide & install pool alarms in accordance with code. Barrier,Temporary. An approved temporary fence, permanent fence,the walls of a grade, the latch handle shall be located at least 3 inches below the top of the gate, 8. See site plan and architectural drawings, by others, for pool location, hardscape permanent structure, or any combination thereof that sufficiently prevents access to the and neither the gate nor the barrier shall have any opening greater than 0.5 inches layout, fence details and construction materials and colors. within 18 inches of the latch handle. swimming pool by any person not engaged in the installation or construction of the swimming R326.4.2.7.3 Locking. All gates shall be securely locked with a key,combination or 9. Do not scale drawings. pool during its installation or construction. other child-proof lock sufficient to prevent access to the swimming pool through such 10. The Contractor is responsible for all means and methods of construction. Hot Tub. See"Spa" gate when the swimming pool is not in use or supervised. 11. All work and materials shall conform to the requirements of the Virginia Graeme Residential. That which is situated on the premises of dwellings regulated under this code,and R326.4.2.8 Dwelling Wall as Barrier.A wall or walls of a dwelling may serve as part of the Baker Pool &Safety Act. detached dwellings classified as R-3 and constructed under the Building Code of New York barrier, provided that the wall or walls meets the applicable barrier requirements of 12• A minimum of 6 inches of crushed stone or gravel shall be installed throughout State. Sections R326.4.2.1 through R3264.2.6, and one of the following conditions shall be met: throughout the entire excavation limits. The excavation limit shall be the pool Spa. A portable or non-portable structure intended for recreational or therapeutic bathing,in 1.) a.) Doors with direct access to the pool through that wall sf all be equipped with an area plus 10 feet in each direction. which all controls,water heating and water-circulating equipment are an integral part of the alarm which produces an audible warning when the door and/or its screen,if present, 13. The pool bottom shall have a non-slip surface finish and pitch per code. product. Spas are shallow in depth and are not designed for swimming or diving. are opened.The alarm shall be listed in accordance with UL 2017.The audible alarm 14. Fences & barriers shall meet or exceed all requirements of the NYS Building Code. Substantial Damaqe. For the purposes of determining compliance with the pool alarm provisions shall activate within 7 seconds and sound continuously for a minimum of 30 seconds Deck Material of this section,damage of any origin sustained by a swimming pool,whereby the cost of restoring after the door and/or its screen, if present, are opened and be capable of being heard the swimming pool to its before-damaged condition would equal or exceed 50 percent of the throughout the house during normal household activitie<-. The alarm shall automatically market value of the swimming pool before the damage occurred. reset under all conditions. The alarm system shall be equipped with a manual means, St. St. Brackets Coping Substantial Modification. For the purposes of determining compliance with the pool alarm such as a touchpad or switch, to temporarily deactivate the alarm for a single opening. _C5� To Support Deck Stone provisions oft is section, any repair, alteration, addition or improvement of a swimming pool, Deactivation shall last for not more than 15 seconds;and Material ' " ' " ' '' ;' Anodized the cost of which equals or exceeds 50 percent of the market value of the swimming pool b.) Operable windows in the wall or walls used as a barrier shall having a latching device St. Steel Tray "' Aluminum B before the improvement or repair is started. If a swimming pool has sustained substantial located no less than 48 inches above the floor. Openings in operable windows shall not ° Track damage, any repairs are considered substantial modifications regardless of the actual repair allow a 4 inch diameter sphere to pass through the opening when the window is in its ° op of B Beam a work performed. largest opened position;and Wall To Be Suction Outlet. A fitting,fitting assembly,cover/grate,sump,and related components that c.) Where the dwelling is wholly contained within the pool barrier or enclosure,alarms shall provide a localized low pressure area for the transfer of water from a swimming pool. be provided at every door with direct access to the poot or Tiled ° 6'!xY Frost-Proof Swimming Pool. Any structure, basin, chamber Or tank which is intended for swimming . < � Water Line Tile g• d.) Other means of protection,such as self-closing doors with self-latching devices,so long ° diving, recreational bathing or wading and which contains, is designed to contain,or is dZ Pool 1/4" Round g as the degree of protection afforded is not less than the protection afforded b Item 1 < Edge capable of containing water more than 24 inches deep at any point. This includes described above. p y Beam ° a as °• ., in-ground,above-ground and on-ground pools, indoor pools, hot tubs,spas and wading pools. R326.4.2.8.1 Alarm Deactivation Switch Location.Where or alarm is provided,the wall. 2-1/2"at Box. 3" . ° - °'I Swimming Pool, In-Door. A swimming pool which is totally contained within a structure and deactivation switch shall be located 54 inches or more cbove the threshold of the door. At inside ool Wall. Underside Track surrounded on all four sides by the walls of the enclosing structure. In dwellings required to be Accessible units,Type A units,or Type B units,the deactivation Extended Walk-On Vanishing Lid p Swimming Pool, Outdoor. Any swimming pool which is not an indoor pool. switch shall be located 48 inches above the threshold of the door. R326.3 Compliance With Other Standards. R326.4.2.9 Pool Structure as Barrier.Where an above-ground pool structure is used as a barrier, R326.3.1 In-ground Pools. In-ground pools shall be designed and constructed in conformance with or where the barrier is mounted on top of the pool structure, the structure shall be designed Cover Box ANSI/APSP/ICC 5 (American National Standard for Residential In-Ground SwimmingPools,2011 g ""' R326.3.2 Above-ground and On-ground )• and constructed in compliance with ANSI/SPSP/ICC 4 and meet the applicable barrier Pool; Side Wall q g and Pools. Above-ground and on-ground pools shall be requirements of Sections R326.4.2.1 through R326.4.2.8. Where the means of access is a ladder T designed and constructed in conformance with ANSI/APSP/ICC 4 (American National Standard or steps,one of the following conditions shall be met: - for Above-Ground/On-Ground Residential Swimming Pools,2012). 1. The ladder or steps shall be capable of being secured, locked or removed to prevent access. B Pool Beam Wall R326.3.3 Permanently Installed Spas and Hot Tubs. Permanently installed spas and hot tubs When the ladder or steps are secured, locked or removed, any opening created shall not o shall be designed and constructed in conformance with ANSI/APSP/ICC 3 (American allow the passage of a 4-Inch-diameter sphere;or D:•.. -Y�-�_ o National Standard for Permanently Installed Residential Spas and Swim Spas,2014). 2. The ladder or steps shall be surrounded by a barrier which meets the requirements of =��= - R326.3.4 Portable Spas and Hot Tubs. Portable spas and hot tubs shall be designed and Sections R326.4.2.1 through R326.4.2.8. ,• ` " f '�,�< - QO constructed in conformance with ANSI/APSP/ICC 3 (American National Standard for R326.4.3 In-Door Swimming Pool.Walls surrounding an in-door swimming pool shall comply with Residential Portable Spas and Swim Spas,2013). Section R326.4.2.8. W 3 Drain-,,,, J R326.4 Barrier Application.The provisions of this section shall control the design of barriers for swimming R326.4.3 Prohibted Locations. Barriers shall be located so as to prohibit permanent strucutres, ''° �. :•:. .•• :r: .:. V '' Gunite Layout at Recessed Box pools,spas and hot tubs. These design controls are intended to provide protection against equipment or similar objects from being used to climb the barrier. A. '' ; ' • '. . , ' potential drowning and near drowning by sufficiently preventing access to swimming R326.5 Entrapment Protection For Swimming Pool&Spa Suction Outlets.Suction outlets shall ' ' '` '"' be designed to produce circulation throw Recessed Concrete Box Dimensions pools,spas,and hot tubs by persons outside the property, persons within the dwelling,and 9 p throughout the pool orspa. Single-outlet systems, To minimize scraping on Cover persons in other parts of the property not contained within the pool enclosure. such as automatic vacuum cleaner systems, or multiple suction outlets,whether C R326.4.1 Temporary Barriers. isolated by valves or otherwise,shall be protected against user entrapment. Typical Underside Track- Box Dimensions Minimum 3-1/2" Between Bottom An outdoor swimming pool shall be surrounded by a temporary barrier R326.5.1 Compliance.Suction outlets shall be designed and installed in acordance Motor Opposite Beaml Throat Depth Width of Stone &Top of Bond Beam. during installation or construction that shall remain in place until a permanent barrier in with the requirements of CPSC 15 USC 8003 and ANSI/APSP; 8-24"ICC 7,where applicable. M O B T D W Stone Must Extend 24" Over Bond compliance with Section R326.4.4 is provided. Exceptions. g R326.6 Suction Outlets.Suction outlets shall be designed to p roduce circulation throughout 32" 101, 1 2"to 12-1/2"12-1/2" Beam. Conceal Leading Edge. 1.Above-ground or on-ground pools where the pool structure constitutes a barrier in the pool or spa. Single-outlet systems,such as automatic vacuum cleaner systems, finished beam compliance with Section R326.4.2.9. or multiple suction outlets,whether isolated by valves or otherwise,shall be protected Alter Dimensions for Pool Cover Box Based On entrapment.user against entra 2.Spas or hot tubs with a safety cover which complies with ASTM F1346,provided that such a g p Manufacturer Installation Specifications. safety cover is in place during the period of installation or construction of a hot tub or spa. R326.6.1 Compliance Alternative.Suction outlets may be designed and installed in The temporary removal of a safety cover as required to facilitate the installation or construction accordance with ANSI/APSP/ICC 7. 11"\Typical AutoCover Details of a hot tub or spa during periods when at least one person engaged in the installation or R326.6.2 Suction Fittings. Pool and spa suction outlets shall have a cover that conforms - N.T.S. Modify Dimensions Per Manufacturer construction is present is permitted. to ANSI/ASME A]12.19.8,or an 18 inch by 23 inch drain grate or larger,Oran approved channel drain system.R326.4.1.1 Height.The top of the temporary barrier shall be at least 48 inches above grade, Exception:Surface skimmers. Auto Cover Notes: measured on the side of the barrier,which faces away from the swimming pool. R326.6.3 Atmospheric Vacuum Relief System Required. Pool and spa single or multiple- 1. Installation to be completed in accordance with manufacturers specifications R326.5.2.2 Replacement by a Permanent Barrier.A temporary barrier shall be replaced by outlet circulation systems shall be equipped with atmospherc vacuum relief should for an extended vanishing lid with underside aluminum track. a complying permanent barrier within either of the following periods: grate covers located therein become missing or broken. This vacuum relief system 2. The tracks must be a true rectangle 1. 90 days of the date of issuance of the building permit for the installation or construction shall include at least one approved or engineered method of the and perpendicular to the unit mechanism of the swimmingpool;or pp g type specified and recessed housing. P herein, as follows: g• 2. 90 days of the date of commencement of the installation or construction of the swimming pool. 1. Safety vacuum relief system conforming to ASME A]12.19.17;or 3. Conduit must be on motor end and shall not protrude more than 4"into box. R326.4.1.2.1 Replacement Extension Subject to the approval of the building official,the time 2. An approved gravity drainage system. 4.The top inside pool corners (above the waterline) must be square, not radius. period for completion of the permanent barrier may be extended for good cause, R326.6.4 Dual Drain Seperation.Single or multiple pump circulation systems have a 5. At the recessed box end, the pool wall (bond beam) must be shot 2-1/2" (2" including, but not limited to, adverse weather conditions delaying construction. minimum of two suction outlets of the approved type. A minimum horizontal or finished with tile) lower than the side walls. R326.4.2 Permanent Barriers.Swimming pools shall be completely enclosed by a permanent or vertical distance of 3 feet shall separate the outlets. These suction outlets shall be piped so that water is drawn through them simultaneously through a vacuum 6. Opening of the track (throat) must be 2-1/2"at box (2"finished with tile), sloping barrier complying with Sections R326.4.2.1 through R326.4.2.6. relief-protected line to the pump or pumps. to 3"inside the pool. R326.4.2.1 Barrier Height and Clearances.The top of the barrier shall be no less than 48 R326.6.5 Pool Cleaner Fittings.where provided,vacuum or pressure cleaner fitting(s) 7. Selection of color cover fabric by owner. D inches above grade, measured on the side of the barrier which faces away from the shall be located in accessible position(s) at least 6 inches and not more wall.pool 8. Leading edge must be set a minimum of 4" back from the p wa . swimming pool. The vertical clearance between grade and the bottom of the barrier than 12 inches below the minimal operational water level or as an attachment D shall not be greater than 2 inches measured on the side of the barrier that faces away to the skimmer(s). from the swimming pool. Where the top of the pool structure is above grade,the R326.7 Swimming Pool&Spa Alarms,Applicability.A swimming pool or spa barrier may be at ground level, or mounted on top of the pool structure. Where the installed or substantially modified after December 14,2006,shall be barrier is mounted on top of the pool structure, the barrier shall comply with Sections Prepared For Larry A. RU r R326.4.2.2 and R326.4.2.3. equipped with an approved pool alarm. Pool alarm shall comply with ry R & W / Engineers, P.C. R326.4.2.2 Solid Barrier Surfaces.Solid barriers,which do not have openings shall not ASTM F2208 (Standard Specification of Pool Alarms),and shall be installed, Island Gunite -� O ' �• �: 4=°�, 380Townline Road,suite�50,Hauppauge,NY 11788 Phone(631)969-8535 Fax(631)969-8518 contain indentations or protrusions except for normal construction tolerances and used and maintained in accordance with the manufacturers instructions Swimming Pools, Inc. tooled masonry joints. and this section. Wiseman Residence /t`:, R326.4.2.3 Closely Spaced Horizontal Members.Where the barrier is composed of Exception:1.A hot tub or spa equipped with a safety cover which complies with ASTM F1346 � `�r ; 8581 New Suffolk Avenue horizontal and vertical members and the distance between the tops of the horizontal 2.A swimmingpool other than a hot tub or spa) equipped GUNITE SWIMMING POOLS ids =�'a':. members is less than 45 inches, the horizontal members shall be located on the swimming p ( p ) q Aped with an automatic `C~ t ? fi iA' CUtr10 Ue, NY 11935 power safety cover which complies with ASTM F1346. ;� ,ayr g pool side of the fence. Spacing between vertical members shall not exceed 1-3/4 R326.7.1 Multiple Alarms.A pool alarm must be capable of detecting entry P.O.Box 1595 g inches in width. Where there are decorative cutouts within vertical members,spacing p P g ry into the ,s, p g water at any point on the surface of the swimming pool. If necessary to provide detection Sag Harbor,N.Y.11963 �805 ( ' Proposed Pool & Spa Notes w e within the cutouts shall not be greater than 1-3/4 inches in width. capability at every point on the surface of the swimming pool,more than one pool alarm Tel.(631}7252721 A,n y�.�, �of-2 Fax.(631)725-4661 �;}, c.���f®fi Dwg.Scale Designed By: Date: shall be provided. E-Mail:IslandGunitePools@GMail.com LIC. No.: 6' As Noted ILAR Sept. 13,2024 2 1 2 3 4 �3 '1 o SITE PLAP BASED Oik'SUM/F-Y DRf.KFi'' BY 1 SECCITICO LAND SURD/EYINIIG PC ' 1 DATED O 7.5.G,?_4 ' 1 ' 1 ZEN DESIGN I 1250 EVERGREEN DRIVE � CUTCHOGUE,NY 11935 i 1 PHONE:631-513.6589 FS ALT N0. ISSUE DATE 1 /r 7 1 01 POOL SITE PLAN 07.2424 ; I \ t / -E%ISTI':G BLOCK PATIO 1 II �. EXISTING 1 11 \ i C 2 ST04Y 1 1 ' 1t FRAI,E RESIDENCE II I E%ISTi"G FRA':E DECK 1 1 Q •4j-EXISTI'4G BLOCI:PATR) I 1 8>15. S=1"25,00"E c•S�F+e.n'I�a` 182.03, EDGE OF MEADOW PER FAWORSUBDIVISIO':A'1P I JM 2 5 2124 ZC ANGBOA-ROOFAMULS PROPOSED POOL / I WISEMAN IE'<S5' RESIDENCE m ry \ 3581 NEW SUFFOLK AVE. ' CUTCHOGUE,NY 11935 1 I S.C.T.M.q 3000-116-OS-1002 • _ I SCALE: 1"-150'-0" A 51"25'00"I;� ~ ►� I DATE: 07.24.24 �• •� " � I DRAWN BY: Z.E.N. SITE PLAN N N ® 0, j'/L 111,D),