Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51371-Z
TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51371 Date: 11/12/2024 Permission is hereby granted to: Christopher Austin 915 Bungalow Ln Mattituck, NY 11952 To: install generatoras applied for with flood permit. Generator must be raised at elevation 8'or higher. Premises Located at: 2200 Deep Hole Dr, Mattituck, NY 11952 SCTM# 123.-4-5.1 Pursuant to application dated 11/12/2024 and approved by the Building Inspector. To expire on 11/12/2026. Contractors: Required Inspections: Fees: GENERATOR $125.00 ELECTRIC -Residential $100.00 CO Accessory $100.00 Flood Permit $150.00 Total $475.00 .. Building Inspector TOWN OF SOUTHOLD —BUILDING DEPARTMENT J " Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 1 1 97 1-0959 47 Telephone (631) 765-1802 Fax (631) 765-9502 htt s //www,s utlio]d(IAzi oy Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Insp parr ....�—... -� .. .- 01�}V p14 '7, . Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. 'T �� I: A.k NSa, 1° lk. 0a:." Date:6/12/23 OWNER(S) OF PROPERTY: Name:Christopher & Elizabeth Austin SCTM # 1000-123-4-5.1 Project Address:2200 Deep Hole Drive, Mattituck �....�wu..� . Phone#:631-466-0124 Email:christopher.austin@rtspeclalty.com _.....��..__._.w. _... ._.........._......_ ... _........................_............ ... .. . Mailing Address:PO Box 15 Laurel, NY 11948 CONTACT PERSON: Name:Megan Carrick ........ _ ...._._w m, Mailing Address:PO Box 877 Jamesport NY 11947 Phone#:631-804-3796 Email:megan.cmtarchitecture@gmail.com DESIGN PROFESSIONAL INFORMATION: Name:Charles Thomas Mailing Address:PO Box 877 Jamesport NY 11947 ........�.�............. _ .............._�.w _ ... . .....ww_.._w_._�w_.__.......��..---- ............... . Phone#:516-702-3519 Email:cdthomas63@aol.com CONTRACTOR INFORMATION: Name:TBD Mailing Address: Phone# .._._._._._......,...w............. _._..._._..——__--------------------- _ �..Emal!—�._... ��.,.__... _.�..ww.... .._.,.._._�_._.�....�. DESCRIPTION OF PROPOSED CONSTRUCTION RNew Structure ❑Addition .❑Alteration ❑Repair *Demolition Estimated Cost of Project: ❑Other $ _ _ __._... .m......... Will the lot be re-graded? �Yesmm�❑..No.��._..�... .........wwww.�...�..w. ..Will excess fill be removedfr.. ..�._._._.....�__�������-µtoµµµ_. om premises? Dyes 0 No 1 1 F_ PROPERTY INFORMATION Existing use of property:Single Family Dwelling Intended use of property:Single Family Dwelling Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_L�O this property? ❑Yes *NO IF YES, PROVIDE A COPY. R s h :a Box After Raad!i13. The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION 15 HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): v. w ,� �r,L` Authorized Agent ❑Owner Signature ofA Applicant: ��� g Pp ���� �.. Date. STATE OF NEW YORK) SS: COUNTY OF being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is theµ (Contractor', Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this a ktday of __ wwwww__ Zp t1 Not PuNc Erin�11'-iYu o( .CJ CE IiC Notary P-jblic State oa f,11�%t York P � ,. ! i r r)VV,i ;fired 1 t U Ly2k i L)'i County of Su rock (Where the applicant is not the owner) ':u i tq l-' 30 Christopher Austin residing at 915 Bungalow Lane ,qq_ Mattituck, NY 11952 Charles Thomas/ Megan Carrick hereby authorize _ w to apply on 2my obethe Town of So ho Building Department for approval as described herein. 6/12/2023 Owner's Signature Date Christopher Austin Print Owner's Name 2 BUILDING DEPARTMENT- Electrical I Pos 4 TOWN OF SOUTH }k^ Town Hall Annex- 54375 Main Ro O Box 1 7 . h � Southold, New York 1197 59 Telephone (631) 765-1802 - FAX ( 765-9502 amesh southoldtownn ov wand soot APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 09/16/2024 Company Name: Modern Electric East, Inc. Electrician's Name: T. Rutkowski License No.: ME 4352 Elec. email:trut299@aol.com Elec. Phone No: 516-903-7151 0 1 request an email copy of Certificate of Compliance Elec. Address.: PO Box 321, Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Chris Austin Address: 2200 Deep Hole Drive Cross Street: Richard Street Phone No.: Bldg.Permit#. email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Wiring of Standby Generator Square Footage: 400 Circle All That Apply: Is job ready for inspection?: L__-1' YES NO n Rough In El Final Do you need a Temp Certificate?: F] YES NO Issued On Temp Information: (All information required) Service SizeF-11 PhF]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 M2 0 H Frame Pole Work done on Service? Y MN Additional Information: Standbv Generator-- $100.00 PAYMENT DUE WITH APPLICATION �'& (!,� IOC) ` l bs-L-Gq XAPPRVEAS IOTEO DA .P Y:NOTEPARTMENT AT 631-765.1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: ELECTRICAL 1. FOUNDATION-TWO P17701 tc r-0 FOR POURED CONGRL"- 2. ROUGH-FRAMING& PLC 3. INSULATION 4, FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES "t"I'll NEW PORK STATE & TOWNS CODES COMPLY C r)E,. SOUPi= ONN PI AMIN G BOARD WHO TOWNS TRUSTEES V , a OLD HPnC OCCUPANCY OR WITHOUT I I "T" GENERAC GUARDIAN® SERIES Residential Standby Generators Air-Cooled Gas Engine rA Standby Power Rating L NCLUQES:, G007290-0,G007291-0(Aluminum-Bisque)-26 kW 60 Hz 0 True Power'" Electrical Technology 0 Two-line multilingual digital LCD Evolution'"controller (English/Spanish/French/Portuguese) 0 200 amp service rated transfer switch available # Electronic governor a° 0 Standard Wi-Fi®connectivity / 0 System status&maintenance interval LED indicators �� M Sound attenuated enclosurea/ ' 0 Flexible fuel line connector jjg ���� 0 Natural gas or LP gas operation � GENERAL � ��aanoDA 05 Year limited warranty tm/m � 0 Base fascia • Listed and labeled for installation as close as 18 in(457 mm)to a structure.` 'Must be located away from doors,windows,and fresh air intakes and in or C �L us .... accordance with local codes. C '1/ uS usrl=.o Nole:CETL or CUL cedificalion only applies to unhundled units and unils packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only ,, wwwwwa� � w �NNNNN�aNN�� w ��� ,,, wwwNNww �w ,NN N„oNw FEATURES II11HIMODfArlIVIE.IEINGIINIE DIESKN N RIIGoDIROUDS'"TE;STRIG are at the heart of Gen- 0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE IREGUDIL.A'T110111� This erac's success in providing the most reliable generators possible. Generac's G- stale-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Farce series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1% a TIREUE IPOWER"'EILIEIATGIIOAII_°FIEC'FNIkIIOLE GY:Superior harmonics and sine wave SIINGILIE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component appliances,such as variable speed HVAC systems. 0 TI SI CIRIrFERIIA: T:r GEIIfNERAO'TRANSFER 1SWVtl'Tf,IHIE& Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION GENERAL POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. MOIEUGLIE LINK`CONNECTIVITY:FREE with select Guardian Series Home standby generators,Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. �fGENERAC Q "" PROMISE .. I G ""`NE RACO 26 kW Specificatio ol ns Gezrwera1:ma r Model G007290-0 G007291-0 (26 kW) Rated maximum continuous power capacity(LP) 26,000 WaOs* Rated maximum continuous power rapacity(NG) 22,500 Watls* Rated voltage 240 Rated maximum continuous load current-240 volts(LPI 108.3/93.8 Total Harmonic Distortion Less than 5% Main line circuit breaker 110 amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) 518/235 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load** 67 Sound output in dB(A)at 23 ft(7 m)with generator in Quiet-Test'"low-speed exercise mode** 57 Exercise duration 5 min Eingine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx.1 9 ql/1.8 L Operating rpm 3.600 Fuel consumption Natural gas ft3/hr(m3/hr) 1/2 Load 1811 Full Load 333(9.43) Liquid propane ffa/hr(gal/hr)[L/hr] 75(2.06)[7.781 1/2 Load Full Load 132(3.63)[13 731 Note:Fuel pipe must be sized forfull load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0,87-1,74 kPa)for NG,10-12 in water column(2.49-2,99 kPa)for LP gas. a ) 'oule content,multiply m3 Far BTU content, /h mullipl fCn/hr x 2500(LP)or ft x 1000(�NG.For Mega /hr x 93 15(LP)or m3/hr x 37.26(NG). G�'a�neGirax�� Two-line plain text multilingual LCD Simple user interface for ease of operation, Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser MANUAL Start with slarler control,unit stays on.II utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/AlamdMainlenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-oul Starter cannot re-engage until 5 sec after engine has slopped Smart Battery Charger Standard Charger Fault/Missing AC warning Standard Low Ballery/Baftery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Ovedoad/Stepper Overcurrenl Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Faull/1nconect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard Rating definitions-Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. *No overkmd capability is„tvOlable for this rating.('Aft wings in accordance with BS5514,103046,UL2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such fatUmsas fuel BTU/Megajoule conleW,wTbient temperature,Mtffude,engine power and condition,etc.Maarrfrrrm mk power decreases approximately 3.5%for each 1,000It(304.8 m)above sea level and appmIKo ately 1% for each 10°F(6°C)above 60°F(16°C).**Sound levels are taken from the front of the generator.Sound levels taken from othersides of the generator may be higher depending on installation parameters. U.S.EPA certified for non-emergency applications vW 26 kW Available Accessories Model# Product Description G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18 DC). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generates scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.it manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G0071 69-0-4G LTE Mobile Link Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-FV Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the fling holes located in the base. Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs —Model .............__....._....-UPC_- ,...........................6[25 1 mm,. .. .................................m.._..........,.....,..,........1276 mm 37 ...w........M.M,.. ' ...............w.........................�.», G007290-0 '�..... 696471087307 �........... ........�.�_.. ......-w.ww._.__ G007291-0 696471087314 _ "�� �f � W® 'M 727 2 [28 6 in] [25.51n [46 5 inl LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximale.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. AL GENERAC, Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com mti�,rmrom�isur�pvr/�tl fPlf4!(y;l i�; (}j�(f", p2p22 Generac Power Systems,Inc.NI rights reserved.All specifications are subject to change without notice.Part No,A0002026894 Hev.0 04/26/2022 ;uata�>�c 9 uvs2us v 03 �'LO WINM u.n�,p 4"(1 ... 1,.ud h n f aY�•m,a<,z y�ii uDl Fr ia.uu.) n)LIP uoi It;j I lti uI. CZ/L l/9 n,]uoiVenpfaa) V?1Iu I1bitLIcl,I; ! "' f:r:,ieni4 a1,uopr>i}gaaa s��uui w}17a{td3i��ail f, KINO S kll" _l A W-)N9 Ica I NOU—)OdEJ 3NO-) J(), liravO'dddv�10 .1 lAflV3Fj J( ur4�1VtJi Vd3(] nm NOC)' arl Sl NOAAAM Ward P@V,TJui0' ggrxanar:� ka�->airWbai ,>,J�dr.ru6Ja:c�sC 1 �idl iJ�pnn���a ua�r"gua:;, �......_.._. _._.__. _ _..w_.._ .... a 6 ofojsA,,; Pyfa.fe``; aaf 3i)(0 !All 40 jW)U]amOpJIr2a7V N `d -Id 31IS � o rra33o CIA,, aM e z.73t �sl 1p TOO OPP Sam- is a> ov a MA WON !0 ATd3YR103 HO WN s101 uuM m9na + • Md El Igo 0 Slot °b 3Rm Nth So 13350 1"' aw OMltld Is x" aso }�{3tIWd9 `ft TOH 1S31 =4 ra V " rtt S 0(Al3NON(V WO Z" �°mow � � �_...311 aau�TG msa� �U N\ .^r ytw , 6� <^ VWY M3N of sA° l a v�3 m ass 0V rrrrrrrrxrrr�i�nr �1 S MAN ;" - ,jl J m c7nrrrrlrrrrrrr 0 vd S G E N E RAC® l _ _ GUARDIAN° SERIES Residential Standby Generators Air-Cooled Gas Engine Standby Power Rating r , INCLUDES: G00729O-0,G007291-0(Aluminum-Bisque)-26 kW 60 Hz • True Power" Electrical Technology • Two-line multilingual digital LCD Evolution'"controller (Eng I ish/Spanish/French/Portuguese) • 200 amp service rated transfer switch available ` • Electronic governor • Standard Wi-FiO connectivity • System status&maintenance interval LED indicators • Sound attenuated enclosure '"F • Flexible fuel line connector ` =, w Natural gas or LP gas operation 4 GENERAC — • 5 Year limited warranty • Base fascia84 _ ) • Listed and labeled for installation as close as 18 in(457 mm)to a structure." 'Must be located away from doors,windows,and fresh airintakes and in ST or C@us n� /' us accordance with local codes. LISTED \.X V � Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are EFL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN &RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%.. O TRUE POWER—ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA M01-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK°CONNECTIVITY:FREE with select Guardian Series Home standby generators,Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. GENERAC Q M1 = . > a PROMISE �.•�•°` GENERAL® 26 icifli Features and Benefits Engine • Generac G-Force design Maximizes'engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows fora smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution'" Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-cut front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. r GENERAC" 26 kW Specifications Generator Model 6007290-0 G007291-0 (26 K Rated maximum continuous power capacity(LP) 26,000 Wafts' Rated maximum continuous power capacity(NG) 22,500 Watts' Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 108.3/93.8 Total Harmonic Distortion Less than 5% Main line circuit breaker 110 amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) 518/235 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 It(7 m)with generator operating at normal load" 67 Sound output in dB(A)at 23It(7 m)with generator in Quiet-Test"low-speed exercise mode" 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx.1.9 qt/1.8 L Operating rpm 3,600 Fuel consumption Natural gas ft'/hr(mYhr) 188(5.32) Full Load Load 333(9.43) Ful Liquid propane 0/hr(gal/hr)[Uhr] 75(206)[7.78] Full Load Load 132(3.63)[13.731 Ful Note:Fuel pipe must be sized tar full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG.1 D-12 in water column(2.49-2.99 kPa)for LP gas. For BTU content,multiply fl3/hr x 2500(LP)or ka/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility hails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/AlarrNMaintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger FaulUMissing AC warning Standard Low Battery/Baffery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Faullnnconect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard Rating definitions—Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. No overload capability is available for this rating.(All ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 It(304.8 m)above sea level and approximately 1% for each 10°F(6°C)above 60 IF(16°C)."Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. U.S.EPA certified for non-emergency applications GENERAC' 26 kW Features and Benefits Installation System ON -14 in(,t5.6 cm)flexible fuel line Luuncutui Liated ANCI LL1.75,'CEA 6.27 outdoor appliance connector for rhP required connection to the gas supply piping. 0 Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wf-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERACO � - 26 kW Available Accessories Model# Product Description 6007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(-18°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0 IF(-18IC). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G0071 69-0-4G LTE Mobile Link'Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-FV Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC 637.6 mm 1216mm [25.1 inl [46.e in] G007290-0 696471087307 G007291-0 696471087314 727.2 mm [26.6 in1 all 0 O Fr T 846 mm 1232.. 125.5 inl [46.5 ini LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RACg Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0902026894 Rev.0 04/26/2022 GENERAC3 26 kW Switch Options Service Hated.Automatic Transfer Switch Features Model G007291.0(26 kW) • Intelligently knailag8s up to fury ah t,uuditivuei loads with no additional hordwaro• rNo;otooles • Up to eight additional large(240 VAC)loads can be managed when Current rating(amps) YUU used in conjunction � _.<_ - - with Smart Management Modules(SMMs). _voltage rating:(VAC). 120/240;10 Utility voltage monitor(fixed)* C Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80% • Main breakers are rated for 80 D�continuous load. -Dropout 65%- Return to Utility.' '` Appro'x'13 sec • 2-pole,250 VAC contactors. EfL or UL listed Standard • Service equipment rated,dual coil design. Enclosore'type NEMq!UL 3R • Rated for both aluminum and copper conductors. Circuit breaker protected 22,000 g"range• 250 MCM-A• Main contacts are silver plated or silver alloy to resist welding and sticking. Lu *Function of Evolution controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly wl Dimensions 200 Amps 120/240,10 Open Transition Service Rated Height Width H1 H2 W1 W2 Depth H2 HI Jcmi, 26.8 30.1 10.5 13.5 6.9 67.95 76.43 26.67 34.18 17.5 ::•r' Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 -DEPTH-