Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50031-Z
OQ"Af Town of Southold 7/31/2024 �. P.O.Box 1179 0 o _ 53095 Main Rd 4,, Sao; Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45413 Date: 7/31/2024 THIS CERTIFIES that the building IN GROUND POOL Location of Property: 3970 N Bayview Rd, Southold SCTM#: 473889 Sec/Block/Lot: 79.-2-3.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/31/2023 pursuant to which Building Permit No. 50031 dated 11/15/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessoryground swimming pool to an existing single-family dwelling as applied for. The certificate is issued to May,Richard&Kathryn of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50031 6/20/2024 PLUMBERS CERTIFICATION DATED Of Myhoofd Signature SOFDI oG TOWN OF SOUTHOLD �c BUILDING DEPARTMENT y�- TOWN CLERK'S OFFICE N o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50031 Date: 11/15/2023 Permission is hereby granted to: May, Richard 3970 N Bayview Rd Southold, NY 11971 To: Construct an accessory inground swimming pool to an existing single-family dwelling as applied for. Pool and pool equipment must maintain a minimum setback of 15 feet. At premises located at: 3970 N Bayview Rd, Southold SCTM #473889 Sec/Block/Lot# 79.-2-3.3 Pursuant to application dated 10/31/2023 and approved by the Building Inspector. To expire on 5/16/2025. Fees: SWIMMING POOLS -IN-GROUND WITH FENCE ENCLOSURE $300.00 CO- SWIMMING POOL $100.00 Total: $400.00 Building Inspector . pF SO!/r�Ql � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin(.8—town.southold.ny.us Southold,NY 11971-0959 Q �yMUNTY,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Richard May Address: 3970 N Bayview Rd city:Southold st: NY zip: 11971 Building Permit#: 50031 Section: 79 Block: 2 Lot: 3.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Platinum East Electric License No: 34091 ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor X 1st Floor Pool X New X Renovation 2nd Floor Hot Tub Addition Surrey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt - Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan . Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 50A Pool Panel 8 Circuit/ 7 Used , (3)Pump 220GFI Heater, (5) Lights 120GFI on Deckbox Trans., Salt Gene., WaterBond Notes: Pool Inspector Signature: Date: June 20, 2024 S.Devlin-Cert Electrical Compliance Form i oF souryo6 � WSOUTHOLOBUILDING ,T WN D PT. -couto, 631-765-1802 IN.SPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY f ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION P;M ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ . ] CODE VIOLATION [ ] PRE.C/O. [ ]. RENTAL REMARKS: E rj 4 r- DATE 17,q INSPECTO OF SOUly�lo E5 �-�C/ / 1 f �-A-V U G e w * TOWN OF SOUTHOLD BUILDING DEPTH 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ]- FIREPLACE & CHIMNEY- [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: TC-/D L, ckl DATE ��' 2 INSPECTOR . a ho�aOE SO(/T,�°� TOWN OF SOUTHO.LD BUILDING DEPT. coulm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] . NSUL TION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIR FETY INSPECTION [ ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION. [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATIO6 [ ] PRE C/O [ <] RENTAL RE ARKS. U"�W lr �o L��v� , — �� T (4,91 a;L, G%4 1 . . DATE INSPECTOR f \` F ♦ice G �i�+ � :` * t • ._ .' St �; \ .:p:� i„a C ��- 9' ,�`•- TVA '). r --I" �. r ma Jl - - j] ��� J ..r f P t � # ��'1.� �• 1 � SIT �`,�� t r w ` it •- jj 14 A Best Regards, Jeff Thanks we sent these to the Building department * D E C E I WE 9 2024 dab� i F 0 r vyylw/ ff J N T r 3 I Best Regards, n E E " E Jeff V J U L 2 9 2024 On Jul 19, 2024, at 3:22 PM, Kim Sperling<kim@eastendpoolking.com> wrote: Building Department Town of Southold Good Afternoon, We wanted to let you know that your final inspection is scheduled for Monday July 22nd+ Thank you, 4 FIELD INSPECTION REPORT DATE COMMENTS O � d FOUNDATION (IST) y ------------------------------------ 4lC FOUNDATION (2ND) z b o J Q ROUGH FRAMING& PLUMBING � 1 W INSULATION PER N.Y. STATE ENERGY CODE 0 ry wl tv44,n - FINAL CAA -Aq v ADDITIONAL COMMENTS 1 I(e I 23 y�4,��. SIP +-LO Y.c c. # -711 a- E1 s� �X N V z H x d H BUILD, 16EPARTMENT-Electrical Inspector MAR 2 5 2024 Y TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 SouthoidfNew York 11971-0959 rf. :; .;1. TQI0phQne(631)765-1802 - FAX (631)765-9502 roaerr(Msoutholdtownny.aov- seandCa southoldtownny.iaov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: 0 Lt L Company Name: P C U-M I JAJC Electrician's Name: J1 & License No.: MLr-3 y®9I Elec. email: /17VM edxS �,. 400- 0l Elec. Phone No: 3I- S7-ftly request n emall copy of Certific a of Compliance Elec.Address.: JOB SITE INFORMATION (Al Information Required) Name: A&v ti' f-JA Li Address: p V - rc u A 0 Cross Street: Phone No.: t,;z - L L - O 1 b0 BIdg.Permit#: Sgo j l email: vc, ,co Tax Map District: 1000 Section: Block. Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUAR F GE (Please Print Clearly): !%J1nm1n) POOL UJ120JC1 IDS S" uare Footage: Circle All That Apply: Is job ready for inspection?: YES[XNO ❑Rough In Final Do you need a Temp Certificate?: El YES O NO Issued On Temp Information: (Ail information required) Service Size71 Ph 73 Ph Size: A # Meters Old Meter# ❑New Service[]Fire Reconnect[]Flood ReconnectElService Reconnect Munderground[{Overhead #Underground Laterals 1 F12 H Frame Pole Work done on Service? Y ON Additional Information: PAYMENT DUE WITH APPLICATION 10(961 �S �S SUILDIIQ� DEPARTMENT-Electrical Inspector MAR 2 5 2024 TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 SoutholdfNew York 11971-0959 Telephone (631) 765-1802 - FAX (631)765-9502 rogerr(ftoutholdtowriny-gov— seand@southoldtownny.C-lov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: Company Name: P Electrician's Name: 4C ITI+- License No.: M Lr- 3 Vol/ Sec. email: �/17VM le6tSf i V4 ©An Elec. Phone No: &31-7 -C' rtific e of Compliance at _&9-i U V t�.I request An email copy of Elec.Address.: JOB SITE INFORMATION (All information Required) Name- MA Li Address: Gi V i L:Lcl) .4 S' S'l, 4-c i Cross Street: Phone No.: L - 01 b 4) Bidg.Permit#: Soo 3 1 - email: a 2 WJ i LTV&�L� 1 Tax Map District: 1000 Section: Block: Lot BRIEF DESCRIPTION OF WORK, INCLUDE SQUAB 7F G-E (Please Print Clearly): _ 51 Square Footage: I -Circle All That Apply: Is job ready for inspection?: ® YES LNO ❑Rough In Final Do you need a Temp Certificate?: El YES(3 NO Issued On Temp Information: (All information required)A # Meters Old Meter# Service Size71 Ph 73 Ph Size: MNewserviceE]Fire Reconnect[]Flood Reconnect Oservice Reconnect r1underground[]overhead #Underground Laterals n 1 [-]2 H Frame Pole Work done on Service? Y ON Additional Information: ,PAYMENT DI PPLICA110N 4 J PERMIT# Address: Switches Outlets GFI's Surface Sconces ` - � H H's UC Lts Fridge HW POOL Panel Fans Mini Fr. W/D Pump Exhaust Oven Sump Heater✓ �G � '`t Trnsfmr �dl .,—� Smokes DW Generator Salt Gen. 'A�4-41 f C A, Water Bond �� Carbon Micro GrbDis Lights--IS7 Heat Pucks ERV HOT TUB/SPA Inst Hot DeHu-m Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments '.o50fFa1 t�oG . TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 ` y oZ . Telephone (631) 765-1802' Fax (631) 765-9502 https://www.southoldtom=.gov Date Received APPLICATION FOR BUILDING PERMIT t For Office Use Only PERMIT NO. 1600, Building Inspector: fl 0CT 3 1 2023 Applications and forms must be filled out in their entirety ancomplete appl�cations,will,not be accepted 1Nhere'the Applicant is notthe-owner,an BuildingP�einartmerat Owner's Town of Soutiield Auth6&�t-iion form(Page 2)shall be cdfhpleted:} Date:10/02/2023 `:OWNER( ) F P OROPERTY ,. Name Kath n Ma SCTM#1 Project Address:3970 North Bayyiew WRoad, Southold Phone#:609-617-2754 Email:jeffmay57@aol.com Mailing Address: rCONTACT'°°PERSON a w Name:Jennifer DelVagl o__rea..._..._.�...._,.._.. u...__.. �.F.. ..........__.._.._._...._.Y_._....r..__. ..._.......v-._-,n....A___...._.-_..__..v__�.._...._...�_ _.__. ..___.__. __...._.�. MailingAddress:PO Box 369 Peconic NY 11958 Phone#:631-734-7600 Email:Wa. eastendpoolkingNcom DESIGN PROFESSIONAL'INFORMATION 3 3. Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION:` 2 Name:Jennifer DelVagylio East ENd Pool King Mailing Address:PO Box 369 Peconic NY 11958 Phone#:631-734-7600 Email:cj@eastendpoolking.com_ry_ q� 'DESCRIPTION OF PROPOSED CONSTRUCTION � ANew Structure ❑Addition nAltPrntinn F IReDair ❑Demolition Estimatel Cost of Project: ❑Other 16x32 Vinyl Pool — 'S i`;� SF $80,000 VO Will the lot be re-graded? ©Yes ❑No Will excess fill be removed from premises? ®Yes El No n 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which pre ses is situated: Are there any c venants and restrii ons with respect to this property? Ye No IF YES,PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable taws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Gass A misdemeanor pursuant to Section 210.45 of the New York State Penal taw. Application Submitted By( n e): BAuthorized Agent ❑Owner Signature of Applicant: Date:CONNIE D.BUNCH Notary Public,State of New York STATE OF NEW YORK) No.01 BU6185050 Qualified in Suffolk County COUNTY OF SS: Commission Expires April 14,2na S\ `" being bein duly sworn deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor/Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. t Sworn before me this day of ,20 cD2) Notary Public PROPERTY OWNER AUTHORRATION (Where the applicant is not the owner) residing at 3970 North Bayview Road Southold, NY 11971 I, Jennifer Del Vag lio Pbr�-�v� -p`�` do hereby authorize k/N�r to apply on my behalf to the Town of Southold Building Department for approval as described herein. )�� '�? - VN k(3 1-2—A IL� J Owner' nature Date 1` bn-1�fZy t"A Print Owner's Name 2 l ® DATE(MM/DOIYYYY) A 0 CERTIFICATE OF LIABILITY INSURANCE F_ 11/28/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAMEACT Barbara Dammers Roy H Reeve Agency,Inc. (PA HONE (631)298 4700 F4X (631)298-3850 AIC No Ext: A/C,No: PO Box 54 E-MAIL s: bdammers@royreeve.com 1340D Main Road INSURERS)AFFORDING COVERAGE NAIC d/ Mattituck NY 11952 INSURER A: Transportation Insurance Company 20.494 INSURED INSURER B: Continental Insurance Company 35289 Eastern End Pools LLC,DBA:East End Pool King INSURER C: Continental Casualty Insurance Company 20443 PO BOX 369 INSURER D: INSURER E: Peconlc NY 11958 1 INSURER F: COVERAGES CERTIFICATE NUMBER: CL22112818102 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY NUMBER MMIDDIYYYY MMID EFF D EXP LIMITS LTR INSD WVD X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGEo 100,000 CLAIMS-MADE FX OCCUR PREMISES Ea occurrence $ X Contractual Liability MED EXP(Any one person) $ 15 0000 A Y Y 6080837145 11/15/2022 11/15/2023 PERSONAL&ADV INJURY $ 1 000, ,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 PRO- LOC PRODUCTS-COMPIOP AGG $ 2.000,000 POLICY �JECT $ OTHER: COMBINED AUTOMOBILE LIABILITY (Ea accident) SINGLE LIMIT $ 1,000,000 ANYAUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED 6080837159 11/15/2022 11115/2023 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS ' HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAB OCCUR EACH OCCURRENCE $CLAI EXCESS LIAB IS-MADEH AGGREGATE $ DIED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY STATUTE ER v/N 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE - NIA 6080837162 11/15/2022 11/15/2023 E.L.EACH ACCIDENT $ O OFFICERIMEMBEREXCLUDED? 1,000,000 (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached If more space Is required) Certificate holder is included as additional insured under General Liability as per the terms and conditions of form#CNA75079XX-Blanket Additional Insured with Products-Completed Operations Coverage Endorsement, Farm CNA74705NY-Contractors GL Extension Endorsement,NY includes waiver of subrogation&primary&non-contributory coverages as required by written contract or agreement. Additional insured under the business auto is included under Form#CNA63359XX-Auto Contractors Extended Coverage Endorsement-Business Auto Plus. RE:COASTAL CONTRACTOTS LICENSE CERTIFICATE HOLDER CANCELLATION _ SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179 AUTHORIZED REPRESENTATIVE Southold NY 11971 __1 ©1988-2015 ACORD CORPORATION. All rigf ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD 7 ® DATE(MM/DD/YYYY) ACOIR 0 CERTIFICATE OF LIABILITY INSURANCE 11/28/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: `If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Barbara Dammers NAME: Roy H Reeve Agency, PHONE (631)298 4700 FAx (631)298-3850 y A/C No Ext: A/C No): PO BOX 54 E-MAIL bdammers@royreeve.com ADDRESS: 13400 Main Road INSURER(S)AFFORDING COVERAGE NAIC S Mattituck NY 11952 INSURER A: Transportation Insurance Company 20494 INSURED _ INSURER B: Continental Insurance Company 35289 Eastern End Pools LLC,DBA:East End Pool King INSURER C: Continental Casualty Insurance Company 20443 PO BOX 369 INSURER D: INSURER E: Peconlc NY 11958 INSURERF: COVERAGES CERTIFICATE NUMBER. CL22112818102 REVISION NUMBER: THIS IS TO CERTIFY THATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MMIDDPOLICY EFF POLICY IYYYY MM DD EXP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 G o 100,000 CLAIMS-MADE �OCCUR PREMISES Ea occurrence $ X Contractual Liability MED EXP(Any one person) $ 15,000 A Y Y 6080837145 11/15/2022 11/15/2023 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 JECT POLICY ❑ PRO ❑LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: AUTOMOBILE LIABILITY Ea aocdeDtSINGLE LIMIT $ 1,000,000 ANYAUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED 6080837159 11/15/2022 11/15/2023 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY AUTOS ONLY Per accident N I - $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ PER I $ WORKERS COMPENSATION STATUTE ER H AND EMPLOYERS'LIABILITY YIN 1,000,000 C ANY PROPRIETOR/PARTNER/EXECUTIVE NIA 6080837162 11/15/2022 11/15/2023 E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? 1,000,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached If more space is required) Certificate holder is included as additional insured under General Liability as per the terms and conditions of form#CNA75079XX-Blanket Additional Insured with Products-Completed Operations Coverage Endorsement, Form CNA74705NY-Contractors GL Extension Endorsement,NY includes waiver of subrogation&primary&non-contributory coverages as required by written contract or agreement. Additional insured under the business auto is included under Form#CNA63359XX-Auto Contractors Extended Coverage Endorsement-Business Auto Plus. RE:COASTAL CONTRACTOTS LICENSE CERTIFICATE HOLDER / _ CANCELLATION _ SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179 AUTHORIZED REPRESENTATIVE Southold NY 11971 @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD 7987 #FILE No, 4 9973 FILED.0 CT 161985 FILM Am � B � trm k..mp,m... 3 w wx• 8 ..�...�• � F• �... r�k cY xaaxma°,a,.ex[maK,[,xs�� z �i" 4� r? •*swv..s., cFnzB�OCP 0T1985; _TTPx)nL.u„ .pry ��• ha° a >w. W'�u.Aa.. .} kq`3x• ' • ea3-.7iM.A.rr'mbwa.trb e ��P t�n►p� Ar4 P °. �em,rur.xxM ws[m p� laY�yv b.M nqw M..e_.a:x°a — ta".VP "° o"no �hn/4ma +pr'°'y / �aHp�' e�mmna�.b A.afed Mr>+M1aw[avabv 0 D G3 � �"V4 [o+b•m4 ubwkxm v,.NMvfas M..r �...e.. A j �� / ✓°4�4 brie = ....... .[[.�s.�.�wx.w ...'_ TTPI°•L g'a[<°E e15reSxL 5Y3fEM 1 SUBDIVISION MAP PREPARED FOR JAMES W. DAWSON [°. nu[e"uaava AT BAYMEW m....e>u..w.°a.m,sa v.e Ecrw.vn a m•°u""cc .a maemx ao .m°mosTe TOWN OF COUNTY,N ...cm o� - wxu, SUFFOLK COUNTY,NEW YORK c°�mcwac,xx nna i o,xeTwx aaw[�"'i.no a O1im�umaiw"i`['�ort ru our m[mxxanox wr:x[n er m u*c-�1�7= _.•w�am�n.w�ay.,wn:wa.sae o�.,�, ••'e'"'+,4 nu[wmrmn ru soma u[ma, wexax,rLwnw x°u° � ° na,x.vxex®ua° .°[en do xx�w,n u own m�ra semn.v[ v; .OCT 1 K Irw `O wre OCT 1r� I ''°•°00` off' i i Fa 5�� Ur P �� D T LD S Y Southold, N.Y. 11971 (516) 765-1938 June 11, 1985 Mr. Richard Cron Attorney at Law Main Road Cutchogue, NY 11935 Re: James W. Dawson Dear Mr. Cron: The following action was taken by the Southold Town Planning Board, Monday, June 10, 1985. RESOLVED that whereas, a formal application for the approval of a subdivision plat entitled "James W. Dawson" located at Southold was submitted to the Planning Board on March 23, 1984 and, filing fee was paid on March 29, 1984, and WHEREAS, a public hearing was held on said subdivision application and plat at the Town Hall, Southold, New York, on May 20, 1985,. at 7:30 p.m. ; and WHEREAS, the requirements of the Subdivision Regulations of the Town of Southold have been met by said subdivision plat and application, NOW, therefore, be it RESOLVED that the application of "James W. Dawson" for approval of said subdivision plat prepared by Howard Yound and last revision dated February 19, 1985,be approved and the chairman be authorized to endorse approval on said subdivision plat subject to the following conditions within six (6) months from the date of this resolution: I. Receipt of four surveys indicating a 10' easement from Lot No. 4 to the open space. 2. Filing of the covenants and restricitions, dated April 24 , 1985 , regarding the Homeowners Association, with the County Clerk. I JAMES W, DAWSON CLUSTER SUBDIVISION DECLARATION 'OF COVENANTS AND RESTRICTIONS LAW OFFICES CRON AND CRON MAIN ROAD P.O.Box 953 CUTCHOGUE, NY 11935 (516)734-5100 i Lti � er � gS7 e 07 DECLARATION OF COVENANTS AND RESTRICTIONS FOR JAMES W. DAWSON CLUSTER SUBDIVISION This Declaration, made the /y day of ( , 1985, by JAMES W. DAWSON, residing at 9 Stone Ledge Road, Upper Saddle River, New Jersey 07458, W I T N E S S E T H DIST. WHEREAS, JAMES W. DAWSON, as the owner in fee simple 1000 of certain premise's in the Town of Southold, County of Suffolk SEC. and State of New York, known and designated on a certain map 079 BLK. entitled, "James W. Dawson at Bayview" , dated September 4 , �1984 , � 02 last amended June 15, 1985, as prepared by Young & Young, L.S. , a LOT subdivision situate at East Marion, Town" of Southold, Countv of 003 Suffolk and State of New York, which subdivision will appear in Lot 003, District 1000, on Section 079, Block 02 /of the Suffolk County Tax Map; and WHEREAS, said JAMES W. DAWSON is improving the afore- described premises as. a planned residential community and contem- plates that lots in said residential community are to be conveyed to individual purchasers; and WHEREAS, JAMES W. DAWSON is desirous of placing certain restrictions upon said premises which shall be binding upon ail purchasers and mortgagees of individual lots, their heirs , execu- tors, administrators and assigns, or other successors in interest; i r l ec r s� ff� Ikcont NOW, THEREFORE, JAMES W. DAWSON declares that the aforesaid land is held and shall be conveyed subject to the following covenants and restrictions, which shall run with the land: (1) No building other than a one-family dwelling with garage (s) shall be erected on any one lot,. ' Each dwelling must have a two-car attached garage, and that any garage must conform in exterior architectural design with the duelling. (2) A one-story dwelling erected shall have a first floor area of not less than 1500 square feet and a two- . story dwelling shall have a first floor area of not less than 1200 square feet, not including porches or garages. (3) Every garage must have •a driveway. The drive- way must have a stone concrete or asphalt surface. (4) The premises shall not be used for the manufac- ture or sale of merchandise or goods of any kind; for any trade or business whatsoever,, or for the display of any advertising or commercial signs. (5) No fowl, poultry, animals or livestock shall be kept on the premises other than two domestic pets which shall be confined exclusively to the owner' s property. (6) No mobile type homes, modular homes, unlicensed 1 motor vehicles and trailers shall be allowed on any lot regard- less of their size with the exception of boat trailers which must be kept in the rear of the premises. i - 2 - (7) Clotheslines shall be restricted to the rear yard. (8) Flat roof construction shall not be used on any buildings, and all buildings must be completed within one year from commencement of construction. (9) The covenants and restrictions herein imposed, as they apply solely to items numbered (1) through (8) inclusive, may be modified, amended, or revoked at any time by the Declarant, his successors or assigns. (10) These covenants and restrictions, as they apply solely to items numbered (1) through (8) inclusive, shall run with the land hereby conveyed and shall bind and inure to the benefit of the said parties hereto, their heirs, administrators and assigns until January 1, 1998, and said covenants and restrictions may be enforced by action for damages or injunctions, or both, until the 1st day of January, 1998 . (11) JAMES W. DAWSON has set aside, as indicated on the subdivision- map, an area consistifig' of 7.459 acres as "open space" for the use of the owners of lots and their guests 'and invitees. Said common land shall be limited to "open space uses" . (12) All owners of lots are hereby granted the right to use, in common with others, at their own risk, the "open space" area. (13) Each lot owner shall be responsible for one- seventh (1/7) of the real estate taxes attributable to the "open space" area. All decisions as to the upkeep and main- tenance of the "open space" area shall be in the exclusive 3 - 1 , discretion of JAMES W. DAWSON, or his successors in interest, or an association of property owners as hereinafter provided. (14) While JAMES W. DAWSON holds title to the "open space" area, he will pay the taxes and expenses mentioned in paragraph (13) above, and will submit bills to the individual lot owners for their respective contributions. Such bills will be paid in full to JAMES W. DAWSON by the then present lot owners within fifteen (15) days after said bills have been mailed. In the event that said bill is not paid when due; the same shall become and remain a lien upon the premises of said owner (s) until paid, and JAMES W. DAWSON, his successors or assigns, shall have the right to collect same and to enforce the lien thereof by any means authorized by law. (15) After a majority of the lots have been con- veyed by JAMES W. DAWSON, said JAMES W. DAWSON, at his cost and expense, shall form, organize and transfer title to the "open space" area to an incorporated non-profit property owners' organization, to be known as the NORTH BAYVIEW ROAD PROPERTY OWNERS' ASSOCIATION, INC. (16) After conveyance is made to the Property O Owners' Association pursuant to paragraph (15) above, then: (a) All costs and expenses associated with the "open space" area shall thereafter be borne entirely by the Property Owners ' Association; the by-laws of said Association, and any amendments thereto, shall be subject to- approval by the Town Board of the Town of Southold. 4 - (b) The owners of all lots purchased from JAMES W. DAWSON shall be members of the Property Owners ' Association; (c) Each member of the Property Owners ' Asso- ciation shall .be liable, on a per lot basis, for a share of the cost and expenses of .the Property Owners' Association; (d) Each member agrees to comply with the regu- lations for the use of the "open space" area enacted by the Property Owners' Association. A majority vote shall be re- quired for the enactment of each such regulation; (e) Title to the "open space" area shall be held in perpetuity by the Property Owners' Association. (f) The owner (s) of each lot shall have one vote for each lot owned, whether improved or unimproved. (g) The area designated "open space" shall remain as such in perpetuity. IN WITNESS WHEREOF, the foregoing Declaration has been executed by JAMES W. DAWSON, on the day and year first above written. STATE OF NEW YORK ) ✓ JAMES W. DAWSON SS. . COUNTY OF SUFFOLK ) �� On this / ` day of !� -1,� 1985, before me personally came JAMES W. DAWSON, to me known and known to me to be the person described in and who executed the foregoing Declaration of Covenants and Restrictions, and he duly acknow- ledged to me that he executed the same. EDNA M, ROUSTON NOTARY PUBLIC, State of New Tork fhss pi Suffolk Comft 306 4. Notary Public Fommissios ioa Expires Un Ysrob Sa 19:,. - 5 - STATE OF NEW YORK ) SS. . COUNTY OF SUFFOLK ) I, the undersigned, am an attorney admitted to practice in the courts of New York State, and certify that the within Declara- tion of Covenants and Restrictions for James W. Dawson Cluster Sub- division has been compared by me with the original and found to be a true and complete copy thereof. R CHA J RON Sworn to before me this ,day of August, 1985. ` EDNA M. MOUSTON POTARY PUB�U Sts 8 Nee y0* 6246344 butlitied in Suffolk County _Q Wmissioa Expira 1srch $O, S*�r SYMBOL LEGEND N'D�� T r El MONUMENT FND I YTjT 7/ ® I.P. /I.B. FND �A l Y I,�V// D ® I.P. ,I.B. SET ' WIDE i 1 L 0�D *N65.55 SPOT ELEVATIONS 71) UTILITY POLE >— GUY WIRE 1_ C:l g UTILITY POLE W/LIGHT LIGHT POLE -� SIGN FIRE HYDRANT 2g6�9 —� PVC FENCE(PVC) 46y i STOCKADE FENCE (STK) —X— CHAIN LINK FENCE (CLF) —_— WIRE FENCE MANHOLE m ES -A--INLET FM LOT 4 g IN °B°-INLET 4 TAX LOT 3.4 r ® YARD INLET / —� 0 ® YARD INLET /' S'68"56'10"E 222.60' Z A/C UNIT + �- q® ELECTRIC METER QO PIPE 3-H o O ❑O GAS METER �' O � WATER METER /� i�,�'�, n` �• I X GAS VALVE .�' FEN• I N_ I O x WATER VALVE FM LOT 5 fjp� +I TEST HOLE TAX LOT 3.5 /•fit / ��s, f 78.7' TREE A / / 12.1' 327 SHRUB • BOLLARD ��pF/ Z w r 2 STORY FRAME . WETLAND FLAG QYA.FP/ o RESIDENCE uj -_ r D.C. DEPRESSED CURB IR Rn #3970 W I� WI� FE. FENCE / FM LOT 3 HAS. MASONRY / I 1s.1' _ I I< PLAT. PLATFORM ++�/ ao TAX LOT 3.3 ivy _ I I W.W. WINDOW WELL to (�O �_i, 1 to B/W BAY WINDOW / i Dy \ .7'• 8.1 I M I iw k C/E CELLAR ENTRANCE oO / p �+ O/H OVERHANG 6✓ / \� h I O O R/O ROOF OVER \ s \y ` N < N I n ��- CANT. CANTILEVER �'� y� 8• \\\ GATE 23.4' I FND _ I {� w PIPE 9 \ w I ------------ i T�I RF \ CO I ------ I ASPHALT DRIVEWAY I I - OPEN SPACE ko I \ _�N I M+I _- ---- -----------{_ 11 l�l TAX LOT 3.10 } �O �I i------ 10.3 ---- I }� M —— -'7 f�sr — \ WRF .SHED SHD �}f1`1', 6'STOCKADE FEN. }t4.9' I O I T/—T— -- —f — -- — — —STK SHD}— —_ 319.79' i LOT AREA N6'8056'10I'II �'�,::�. ,��' / f44..4'} FEN FEN f4.0' t6.5'} I I 41,133t S.F. GRAPHIC SCALE j ;. FM LO O''� i 0.94t AC. T 2 ao 0 20 40 TAX LOT 3.2 GUARANTEED TO: RICHARD J. MAY KATHRYN B. MAY IN FEET FIDELITY NATIONAL TITLE INSURANCE SERVICES, LLC 1 inch = 40 ft. ------ / SUFFOLK TAX MAP NO. SURVEY OF PROPERTY C)F Ne /f f 1000-079.00-02.00-003.003SCALICE LOT 3 I MAP OF JOB No.S20-3048 JAMES W. DAWSON FILE DATE: 10/16/1985 MAP NO. 7987 a n d surveying DATE SURVEYED: 12/31/2020 SITUATE SOUTHOLD mj s I a n d s u r v e y . C 0 m P: 631 -957-2400 DR.:MC CREW.:AN SCALE: 1" = 40' SUFFOLK COUNTY, NEW YORK (1)UNAUMORRED ALTERATION OR ADDRION TO TNIS SURVEY NAP BEARING A LICENSED LAN SURVEYOR'S SEAL IS A VIOLATION OF SECTION 7209,SUB-OMSION 2,OF NEW PORK STATE EDUCATION UW.(2)ONLY BOL OW SURVEY MAPS WITH THE SUi R'S D1BOSSED SEA.PRE GENUINE TRUE AND CORRECT COPIES OF THE SVRV R'S ORIGINAL WORK AND OPINION.(a)CFROFICATIONS ON THIS BOUNWRT SURvE!YAP SGnFY TINT THE NAP WAS PREPARED N ACCCRDN'CE WIN THE CURRENT METING WOE OF O'S9'86� PRACITM FOR LAND SUM ADOPTED ITT THE NEW YORK STATE ASSOCIATION OF PROFESSI LAND SURVE OM INC.THE CERTIFICATION IS LIMITED TO PERSONS FOR WHO.THE BOUNMM VEY SUR NAP IS PREPARED,TO THE TNLE COYPA-Y,TO THE GOVDiNMENTAL AGENCY.AND TO THE LENDING WSITTL SURVEY MAP.LISTED ON THIS BOUNDARY SUR MAP.(4)THE CERTIFICATIONS HERON ARE NOT TRANSFERABLE(5)THE LOCATION OF UNOERCROUNO INPROVEMEM5 OR FNCRO MENTS ME NOT ALWAYS KNOWN AND OFTEN MUST BE ESTIMATE). IF ANT LMDERGROUND IMPROVEMENTS OR ENCROACHMENTS EAST OR ARE SHOWN.THE WROV ENTS OR ENCROACHMENTS ARE NOT COVERED ITT THIS SUM.(B)THE OFFSET(OR DUAL NS)SHOWN HEREON FiiDM THE SIRUCNflES TO THE PROPMN LINES ARE FOR A SPECIFIC PURPOSE AND USE AND THEREFORE ARE NOT MENDED TO GUIDE THE ERECTION OF FENCES.REFAN ING WALLS,POOLS.PATIOS PLANTING AREAS,ADDITIONS TO BULL MGS.AND ANY OTHER TYPE OF CONSTRUCTION.(7)P.®PER7Y CORNER MONUMENTS WERE NOT SET AS PART OF THIS SURVEY.(B)THIS SURMEy WAS PERORMED WITH A SPECTRA FOCUS 30 ROBOTIC TOTAL STATION.(9)THE EOLISTENCE OF 18GFITS OF WAY PND/OR EASEMENTS OF RECORO'IF ANY,NOT SHOWN ARE NOT GUARANTEED.(10)SURVEY IS SUBJECT TO ANY STATE OF FACTS WHICH AN UP-TO-DATE TIRE EJN.UINADON MAY DISCLOSE � OQ APPROVED AS NOTED DATE.I - 5-23B.P# 5CO31 111 Ll CO. 00 B�: .�_ COMPLY WITH ALL CODES OF NOTIFY BUILDING DEPARTMENT AT NEW YORK STATE&TOWN CODES MI-765-1802 8AM TO 4PM FOR THE REQUIRED AND CONDITIONS OF FOLLOWING INSPECTIONS: 0=70uzm FOUNDATION-TWO REQUIRED pM MR=G BOARD FOR POURED CONCRETE SMHOtflt11RUST�S ROUGH-FRAMING&PLUMBING V INSULATION } FINAL-CONSTRUCTION MUST $AID BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS ELECTRICAL INSPECTION REQUIRED "IMMEMATEI:Y" ENCLOStPOOL TO BODE UPON COMPL01ON RETAIN STORM WATER RUNOFF BEFORE"WATER" PURSUANT TO CHAPTER 236 OF THE TOWN CODE All exterior lighting installed,replaced or repaired shall conforms to Chapter 172 of the Town Code POOL NOTES: 2020 RESIDENTIAL CODE OF NYS,SECTION R326 SWIMMING POOLS,SPAS AND HOT TUBS 1.POOL AND PROPERTY TO CONFORM TO 202O NYS UNIFORM FIRE PREVENTION AND BUILDING CODE, TEMPORARY BARRIERS R326.4.1: CLEARANCE 6" 1. TOWN OF SOUTHOLD CODE AND 2017 NATIONAL ELECTRIC CODE. C MAIN DRAIN 2.POOL SHALL CONFORM TO ANSI/APSP/ICC 5 STANDARDS R326.3.1. AN OUTDOOR SWIMMING POOL,SHALL BE SURROUNDED BY ATEMPORARY BARRIER DURING INSTALLATION OR CONSTRUCTION AND BETWEEN POOL LINE TO 3.SECTION R326.7 POOL ALARM REQUIRED. SHALL REMAIN IN PLACE UNTIL PERMANENT BARRIER IN COMPLIANCE WITH SECTION R326.4.2IS PROVIDED. AND WALL FILTER 4.POOL SHALL COMPLY WITH BARRIER REQUIREMENTS SECTION R326.4. 1.THE TOP OF THE TEMPORARY BARRIER SHALL BE AT LEAST 48 INCHES(1219 MM)ABOVE GRADE MEASURED ON THE SIDE OF THE 5.POOL SHALL COMPLY WITH 2O20 ENERGY CONSERVATION CONSTRUCTION CODE OF NYS SECTION BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL. R403.10: 2.REPLACEMENT BY A PERMANENT BARRIER. A TEMPORARY BARRIER SHALL BE REPLACED BY A COMPLYING PERMANENT BARRIER POOLS AND PERMANENT SPA ENERGY CONSUMPTION(MANDATORY). WITHIN EITHER OF THE FOLLOWING PERIODS: SECTION R403.10.1 HEATERS A)90 DAYS OF THE DATE OF ISSUANCE OF THE BUILDING PERMIT FOR THE INSTALLATION OR CONSTRUCTION OF THE SWIMMING SECTION R403.10.2 TIME SWITCHES POOL;OR SECTION R403.10.3 COVERS B)90 DAYS OF THE DATE OF COMMENCEMENT OF THE INSTALLATION OR CONSTRUCTION OF THE SWIMMING POOL. 6.REBAR SHALL BE 3 MIN.CLEAR TO EARTH. �`''• 7.LOCATION OF PROPOSED SWIMMING POOL AND POOL EQUIPMENT BY OTHERS AND SHALL COMPLY PERMANENT BARRIER R326.4.2: WITH ALL LOCAL ZONING REQUIREMENTS. 8.ALL DRAIN COVERS TO MEET ALL REQUIREMENTS OF THE VIRGINIA GRAEME BAKER(VGB)POOL AND 1.THE TOP OF THE BARRIER SHALL BE NO LESS THAN 48 INCHES(1219MM)ABOVE GRADE MEASURED ON THE SIDE OF THE BARRIER PROVIDE 2 MAIN DRAINS `., SPA SAFETY ACT, THAT FACES AWAY FROM THE SWIMMING POOL.THE VERTICAL CLEARANCE BETWEEN GRADE AND THE BOTTOM OF THE BARRIER WITH STRAINER (VGB � 9.SLOPE PATIO SURFACE 1/4"PER FOOT AWAY FROM POOL. SHALL BE NOT GREATER THAN 2 INCHES(51 MM)MEASURED ON THE SIDE OF THE BARRIER THAT FACES AWAY FROM THE SWIMMING SUNDECK SAFETY ACT APPROVED UNDERWATER 10.BACKFILL MATERIAL TO BE FREE DRAINING GRANULAR MATERIAL(NO CLAY OR LARGE ROCKS). POOL. WHERE THE TOP OF THE POOL STRUCTURE IS ABOVE GRADE,THE BARRIER MAY BE AT GROUND LEVEL,OR MOUNTED ON TOP DRAINS) LIGHT (TYP.) 11.SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ANSI/APSP/ICC 7. OF THE POOL STRUCTURE. WHERE THE BARRIER IS MOUNTED ON TOP OF THE POOL STRUCTURE,THE BARRIER SHALL COMPLY WITH 12.ENTRAPMENT PROTECTION REQUIRED SECTION R326.5. SECTIONS R326.4.2.2 AND R326.4.2.3. 13.POOL WALLS ARE NOT DESIGNED FOR SURCHARGE LOADS EXERTED BY WHEEL LOADS WITHIN SIX(6) 2.SOLID BARRIERS WHICH DO NOT HAVE OPENINGS,SHALL NOT CONTAIN INDENTATIONS OR PROTRUSIONS EXCEPT FOR NORMAL #i 1 FEET OF POOL WALL FROM CONSTRUCTION EQUIPMENT OR ANY OTHER LOADING CONDITION IMPOSED CONSTRUCTION TOLERANCES AND TOOLED MASONRY JOINTS. PROPOSED ON THE POOL STRUCTURE BY EXISTING OR PROPOSED ADJACENT STRUCTURES.IF SITE CONDITIONS DIFFER 3.WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE 18' A I A FROM THIS PLAN,IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT HM ENGINEERING,P.C. HORIZONTAL MEMBERS IS LESS THAN 45 INCHES(1143 MM),THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE SWIMMING VINYL SWIMMING POOL BEFORE ANY CONSTRUCTION BEGINS. POOL SIDE OF THE FENCE. SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 1-3/4 INCHES(44 MM)IN WIDTH.WHERE 16 5.0 14,NO DIVING EQUIPMENT PERMITTED. THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS,SPACING WITHIN THE CUTOUTS SHALL NOT BE GREATER THAN 1-3/4 512 S.F. 15.POOL O REMAIN PERMANENTLY FILLED. INCHES(44 16.CONTRACTOR SHALL VERIFY ) WIDTH.Y SOIL BEARING LOADS PRIOR TO INSTALLATION OF POOL. 4.WHERE THE ARRIER S COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE 17.THIS PLAN IS FOR CONSTRUCTION ON PROPERTY AT 3970 NORTH BAYVIEW ROAD,SOUTHOLD,N.Y. HORIZONTAL MEMBERS IS 45 INCHES(1143 MM)OR MORE,SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 4 INCHES(102 11971 ONLY. MM).WHERE THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS,SPACING WITHIN THE CUTOUTS SHALL NOT EXCEED 1- I 18.REINFORCING STEEL SHALL BE INTERMEDIATE GRADE BILLET STEEL WITH A MINIMUM LAP OF 30 BAR 3/4 INCHES(44 MM IN WIDTH. DIAMETERS. S.MAXIMUM MESH SIZE FOR CHAIN LINK FENCES SHALL BE A 2-1/4-INCH(57MM)SQUARE UNLESS THE FENCE HAS SLATS FASTENED AT THE TOP OR THE BOTTOM WHICH REDUCE THE OPENINGS TO NOT MORE THAN 1-3/4 INCHES(44 MM). STEPS (VINYL 6.WHERE THE BARRIER IS COMPOSED OF DIAGONAL MEMBERS,THE MAXIMUM OPENING FORMED BY THE DIAGONAL MEMBERS OVER /� GENERAL NOTES: SHALL BE NOT GREATER THAN 1-3/4 INCHES(44 MM). CONCRETE) LINE OF 7.GATES SHALL COMPLY WITH THE REQUIREMENTS OF SECTION R326.4.2.1 THROUGH R326.4.2.6 AND WITH THE FOLLOWING COPING \ 1. HM ENGINEERING,P.C.SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS, REQUIREMENTS: CONTINUOUS TECHNIQUES OR PROCEDURES UTILIZED BY THE CONTRACTOR,NOR FOR THE SAFETY OF THE 7.1. ALL GATES SHALL BE SELF-CLOSING.IN ADDITION,IF THE GATE IS A PEDESTRIAN ACCESS GATE,THE GATE SHALL OPEN OUTWARD, PUBLIC OR CONTRACTOR'S EMPLOYEES,OR FOR THE FAILURE OF THE CONTRACTOR TO CARRY AWAY FROM THE POOL. CONCRETE WALL (SEE OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7.2. ALL GATES SHALL BE SELF-LATCHING,WITH THE LATCH HANDLE LOCATED WITHIN THE ENCLOSURE(LE,ON THE POOL SIDE OF THE DETAIL THIS SHEET) ENCLOSURE)AND AT LEAST 40 INCHES(1016 MM)ABOVE GRADE. IN ADDITION,IF THE LATCH HANDLE IS LOCATED LESS THAN 54 2. SELECT GRANULAR FILL/MATERIAL SHALL BE AS DEFINED IN THE REQUIREMENTS OF THE INCHES(1372 MM)FROM GRADE,THE LATCH HANDLE SHALL BE LOCATED AT LEAST 3 INCHES(76 MM)BELOW THE TOP OF THE GATE, MUNICIPAL AGENCY HAVING JURISDICTION AND AS A MINIMUM DEFINED IN SECTION 203 OF AND NEITHER THE GATE NOR THE BARRIER SHALL HAVE ANY OPENING GREATER THAN 0.5 INCH(12.7 MM)WITHIN 18 INCHES(457 N.Y.S.D.O.T.STANDARD SPECIFICATIONS,LATEST EDITION. MM)OF THE LATCH HANDLE. 7.3. ALL THE GATES SHALL BE SECURELY LOCKED WITH A KEY,COMBINATION OR OTHER CHILD PROOF LOCK SUFFICIENTTO PREVENT 3. COMPACTION SHALL CONFORM TO THE REQUIREMENTS OF THE MUNICIPAL AGENCY HAVING ACCESS TO THE SWIMMING POOL THROUGH SUCH GATE WHEN THE SWIMMING POOL IS NOT IN USE OR SUPERVISED. 32' JURISDICTION AND AS A MINIMUM DEFINED IN SECTION 203 OF N.Y.S.D.O.T.STANDARD 8. A WALL OR WALLS OF A DWELLING MAY SERVE AS PART OF THE BARRIER,PROVIDED THAT THE WALL OR WALLS MEET THE SPECIFICATIONS,LATEST EDITION. APPLICABLE BARRIER REQUIREMENTS OF SECTIONS R326.4.2.1 THROUGHT R326.4.2.6 AND ONE OF THE FOLLOWING CONDITIONS SHALL BE MET: 34' 4. ALL FILL/BACKFILL SHALL BE SELECT GRANULAR MATERIAL,COMPACTED TO 95%MAXIMUM 1.a. DOORS WITH DIRECT ACCESS TO THE POOL THROUGH THAT WALL SHALL BE EQUIPPED WITH AN ALARM WHICH PRODUCES AN DENSITY AT OPTIMUM MOISTURE,AS DETERMINED BY MODIFIED PROCTOR TEST,UNLESS AUDIBLE WARNING WHEN THE DOOR AND/OR ITS SCREEN,IF PRESENT,ARE OPENED.THE ALARM SHALL BE LISTED IN ACCORDANCE OTHERWISE NOTED. WITH UL 2017. THE AUDIBLE ALARM SHALL ACTIVATE WITHIN 7 SECONDS AND SOUND CONTINUOUSLY FOR A MINIMUM OF 30 SECONDS AFTER THE DOOR AND/OR ITS SCREEN,IF PRESENT,ARE OPENED AND BE CAPABLE OF BEING HEARD THROUGHOUT THE 5. DEBRIS SHALL NOT BE BURIED ON THE SUBJECT SITE. ALL UNSUITABLE MATERIAL,SURPLUS HOUSE DURING NORMAL HOUSEHOLD ACTIVITIES, THE ALARM SHALL AUTOMATICALLY RESET UNDER ALL CONDITIONS. THE ALARM MATERIAL AND DEBRIS SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL,TOWN, SYSTEM SHALL BE EQUIPPED WITH A MANUAL MEANS,SUCH AS TOUCH PAD OR SWITCH,TO TEMPORARILY DEACTIVATE THE ALARM COUNTY,STATE AND FEDERAL LAWS AND APPLICABLE CODES. FOR A SINGLE OPENING. DEACTIVATION SHALL LAST FOR NOT MORE THAN 15 SECONDS; AND b.OPERABLE WINDOWS IN THE WALL OR WALLS USED AS A BARRIER SHALL HAVE A LATCHING DEVICE LOCATED NO LESS THAN 48 POOL ABOVE THE FLOOR.OPENINGS IN OPERABLE WINDOWS SHALL NOT ALLOW A 4-INCH-DIAMETER SPHERE TO PASS THROUGH POOL PLAN THE OPENING WHEN THE WINDOW IS IN ITS LARGEST OPENED POSITION;AND NOTE: c.WHERE THE DWELLING IS WHOLLY CONTAINED WITHIN THE POOL BARRIER OR ENCLOSURE,ALARMS SHALL BE PROVIDED AT THIS IS A NON-DIVING POOL EVERY DOOR WITH DIRECT ACCESS TO THE POOL;OR SCALE: 1/4" = 1�-��� 2. OTHER APPROVED MEANS OF PROTECTION,SUCH AS SELF-CLOSING DOORS WITH SELF-LATCHING DEVICES,SHALL BE ACCEPTABLE SO LONG AS THE DEGREE OF PROTECTION AFFORDED IS NOT LESS THAN THE PROTECTION AFFORDED BY ITEM 1 DESCRIBED ABOVE. 8.1 ALARM DEACTIVATION SWITCH LOCATION.WHERE AN ALARM IS PROVIDED,THE DEACTIVATION SWITCH SHALL BE LOCATED 54 INCHES OR MORE ABOVE THE THRESHOLD OF THE DOOR.IN DWELLINGS REQUIRED TO BE ACCESSIBLE UNITS,TYPE A UNITS,OR TYPE B UNITS,THE DEACTIVATION SWITCH SHALL BE LOCATED 48 INCHES ABOVE THE THRESHOLD OF THE DOOR, 9. WHERE AN ABOVE-GROUND POOL STRUCTURE IS USED AS A BARRIER,OR WHERE THE BARRIER IS MOUNTED ON TOP OF THE POOL STRUCTURE,THE STRUCTURE SHALL BE DESIGNED AND CONSTRUCTED IN COMPLIANCE WITH ANSI/APSP/ICC 4 AND MEET THE APPLICABLE BARRIER REQUIRMENTS OF SECTIONS R326.4.2.1 THROUGH R326.4.2.8.WHERE THE MEANS OF ACCESS IS A LADDER OR STEPS,ONE OF THE FOLLOWING CONDITIONS SHALL BE MET: 32' 9.1. THE LADDER OR STEPS SHALL BE CAPABLE OF BEING SECURED,LOCKED OR REMOVED TO PREVENT ACCESS.WHEN THE LADDER OR STEPS ARE SECURED,LOCKED OR REMOVED,ANY OPENINGS CREATED SHALL NOT ALLOW THE PASSAGE OF A 4-INCH-DIAMETER 3'-4" 6" WATER LINE SPHERE;OR 9.2. THE LADDER OR STEPS SHALL BE SURROUNDED BY A BARRIER WHICH MEETS THE REQUIREMENTS OF SECTIONS R326.4.2.1 THROUGH R326.4.2.8. is": . ' ;•4; " ' STEPS " ; '`'`"m: CONCRETE WALL ENTRAPMENT PROTECTION R326.5: .....11,...... (SEE DETAIL THIS SUCTION OUTLETS SHALL BE DESIGNED TO PRODUCE CIRCULATION THROUGHOUT THE POOL AND SPA. SINGLE-OUTLET SYSTEMS, SHEET) SUCH AS AUTOMATIC VACUUM CLEANER SYSTEMS,OR MULTIPLE SUCTION OUTLETS,WHETHER ISOLATED BY VALVES OR OTHERWISE SHALL BE PROTECTED AGAINST USER ENTRAPMENT. ,,.,...rs,,:,,E .., .. ."..._m. .. , m• :-£$.•i -,;;_ ?-..-- ?..••<••;•# i-;-;,€ ;� , .., f -E E- I 1.SUCTION OUTLETS MAY BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF CPSC 15 USC 8003 AND ANSI/ 8 ";7T APSP/ICC 7,WHERE APPLICABLE. .,..,�: UNDISTURBED ....E, . :- • _.,£#v.._;;;__.,,:,; •r•;<..::;---•a.�..;:.., .�_�:;-;'r<,W:.;...::;,<E�i�.!.::E...... #f.-....: ;E#.,�.. �I �-t�. SUCTION OUTLETS R326.6:CAST IRON FRAME 3 COVER UNDISTURBED ....Ii. : i `- °7- -•= . -•'•., -•••;# 7 UNDER PAVED AREA FINISHED GRADE SUCTION OUTLETS SHALL BE DESIGNED TO PRODUCE CIRCULATION THROUGHOUT THE POOL AND SPA. SINGLE-OUTLET SYSTEMS EARTH ' `:! ,w E Iµ III';:-.1 s`.m::I! R MULTIPLE SUCTION OUTLETS,WHETHER ISOLATED B E.._.,•�'_.. E •..;, •I s ,;.......#,E-...:..:: SUCH AS AUTOMATIC VACUUM CLEANER SYSTEMS,0 ETS,W SO Y VALVES OR OTHERWISE, ' # :-••;;;•• •E,; :I ,,,., ,,-•:-.:#:••••- - ..-� B' MIN. 12• MAX. `4• SHALL BE PROTECTED AGAINST USER ENTRAPMENT. COURSE BRICK LEVELING CO MIN i 1.SUCTION OUTLETS MAY BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ANSI/APSP/ICC 7. 2 SAND BOTTOM PRECAST CONC. COLLAR" CONCRETE COVER Z.POOL AND SPA SUCTION OUTLETS SHALL HAVE A COVER THAT CONFORMS TOANSI/ASME A112.19.8,OR AN 18 INCH X 23 INCH 'E 7 7 E�� i, s i..,..,:f 1.... '! _j s:........:.:........f k; E, .. ..t I;,,,...•1 i,.,. %.:,"...•:'...i..:: "G`.:_'E i i.,:;,z; ";,,t,#...I:i..i.'cM.(i.✓_t € ;;,:.. ;;....%i`I_,.E r•g,1, TAMPED & ROLLED Max c�Oi PRECAST (457MM BY 584 MM}DRAIN GRATE OR LARGER,OR AN APPROVED CHANNEL DRAIN SYSTEM. 3.POOL AND SPA SINGLE-OR MULTIPLE-OUTLET CIRCULATION""""" AS REQUIRED CULATION SYSTEMS SHALL BE EQUIPPED WITH ATMOSPHERIC VACUUM RELIEF SHOULD GRATE COVERS LOCATED THERE IN BECOME MISSING OR BROKEN. THIS VACUUM RELIEF SYSTEM SHALL INCLUDE AT LEAST 8' 14' 6' 4' REINF. CONC. ONE APPROVED OR ENGINEERED METHOD OF THE TYPE SPECIFIED HEREIN,AS FOLLOWS: DOME 1.SAFETY VACUUM RELEASE SYSTEM CONFORMING TO ASME A112.19.17;OR 4'0 PVC 2.AN APPROVED GRAVITY DRAINAGE SYSTEM. MIN. SLOPE 1/8' 4.SINGLE OR MULTIPLE PUMP CIRCULATION SYSTEMS HAVE A MINIMUM OF TWO SUCTION OUTLETS OF THE APPROVED TYPE.A PER FOOT ® cm ®®11 MINIMUM HORIZONTAL OR VERTICAL DISTANCE OF 3 FEET SHALL SEPARATE THE OUTLETS.THESE SUCTION OUTLETS SHALL BE PIPED :�F INVER ® ®®0 SO THAT WATER IS DRAWN THROUGH THEM SIMUTANIOULSY THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP OR NON-SHRINK ®®� it PUMPS. GROUT 5.WHERE PROVIDED,VACUUM OR PRESSURE CLEANER FITTING SHALL BE LOCATED IN AN ACCESSIBLE POSITION AT LEAST 6 INCHES SECTION A-A ®� 3' MIN. SAND a AND NOT MORE THAN 12 INCHES BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR AS AN ATTACHMENTTO THE SKIMMER. SCALE: F/4" � � -011 AL ~aAN LLARA(TYP) J a ALVEL L AROUND ' SWIMMING POOL AND SPA ALARMS R326.7: to w PRECAST APPLICABILITY.A SWIMMING POOL OR SPA INSTALLED CONSTRUCTED OR SUBSTANTIALLY MODIFIED AFTER DECEMBER 14 2006 F CONC. LEACHING � , RINGS SHALL BE EQUIPPED WITH AN APPROVED POOL ALARM.POOL ALARMS SHALL COMPLY WITH ASTM F2208(STANDARDS w SPECIFICATIONS FOR POOL ALARMS),AND SHALL BE INSTALLED,USED AND MAINTAINED IN ACCORDANCE WITH THE NOTES: y w MANUFACTURER'S INSTRUCTIONS AND THIS SECTION. 1.ALL MANUFACTURED ITEMS AND CONSTRUCTION SHALL COMPLY WITH THE 2020 W 6' DIAMETER EXCEPTIONS RESIDENTIAL CODE OF NYS,INCLUDING THE SPECIFICATIONS IN SECTION R326. 10" TRACK FOR <5 1.A HOT TUB OR SPA EQUIPPED WITH A SAFETY COVER WHICH COMPLIES WITH ASTM F1346. 2.CONTRACTOR SHALL PROVIDE DEEP END SWIM OUT TO CODE, VINYL LINER Bad 2.A SWIMMING POOL(OTHER THAN A HOT TUB OR SPA)EQUIPPED WITH AN AUTOMATIC POWER SAFETY COVER WHICH COMPLIES 3.SEE SITE PLAN BY OTHERS FOR LOCATION OF PROPOSED SWIMMING POOL,POOL ha, EQUIPMENT,SITE GRADING AND DRAINAGE FOR PROPERTY. TH ASTM F1346. VINYL LINER �� POIOL ALARMS SHALL COMPLY WITH ASTM F2208,AND SHALL BE INSTALLED,USED AND MAINTAINED IN ACCORDANCE WITH THE .. ...,:.I I ;__-_____' I I..;.,.,:-,...,,E •. • € i 3...._.__.... € ................. ::. .a..._ ,:::W 4.::•.,w.:b,..:.:�.:o..::�,•o INSTRUCTIONS AND THIS SECTION. FOAM PADDING 3,50)PSI _ � 326.7F1 MULTIPLE ALARMS,A POOL ALARM MUST BE CAPABLE OF DETECTING ENTRY INTO THE WATER AT ANY POINT ON THE CONCRETE :...............: i °. _ .. .•;� • .� ';• . :: � �. SURFACE OF THE SWIMMING POOL. IF NECESSARY TO PROVIDE DETECTION CAPABILITY AT EVERY POINT ON THE SURFACE OF THE SWIMMING POOL,MORE THAN ONE POOL ALARM SHALL BE PROVIDED. z N. PENETRA ION R326.7.2 ALARM ACTIVATION. POOL ALARMS SHALL ACTIVATE UPON DETECTING ENTRY INTO THE WATER AND SHALL SOUND ....._..........: ....,,.__ iu INTO VIRGIN STRATA a ' ' ""..... GROUND WATER OF SAND 6 GRAVEL POOLSIDE AND INSIDE THE DWELLING. NDISTURBED _ _ _ R326.7.3 PROHIBITED ALARMS. THE USE OF PERSONAL IMMERSION ALARMS SHALL NOT BE CONSTRUED AS COMPLIANCE WITH THIS - = - EARTH -- -- - E SECTION. 1 1/2"TO WASTE #4 REBAR TOP, _ 4 I I MIDDLE&BOT. ___I I I DRAINAGE POOL DETAIL 1 HAIR&LINT STRAINER 48 NOT TO SCALE - PUMP I.............µ"1 , NO. DATE DESCRIPTION BY a I NOTES: owNER: PROPOSED SWIMMING POOL FOR FILTER AUTO SKIMMER 1 I I.. JEFF & KATE MAY µ MAY RESIDENCE 1 ! " ;#4 REBAR 1. UNSUITABLE MATERIAL SHALL BE REMOVED UNDER LEACHING POOL UNTIL 6'MINIMUM JEFF NORTH BAYVIEW ROAD HARD BOTTOM 40 EVERY 2'O.C. PENETRATION INTO VIRGIN STRATA SAND AND GRAVEL AND BACKFILLED WITH SAND AND VERTICAL SOUTH 1971 I •__......... 1 GRAVEL TO BOTTOM OF BASIN. OLD, N.Y.. JEFF NORTH BAYVIEW ROAD .�............ _: # . POOL : DUAL MAIN DRAIN WITH ; 12.AS AN ALTERNATIVE TO THE DOME TOP,A FLAT SLAB CAN BE SUBSTITUTED WITH SITUATED AT BACK TO POOL HYDROSTATIC VALVE i ° ° e I I APPROVAL OF THE ENGINEER. -- APPLICANT: AND COLLECTOR TUBE JEFF & KATE MAY SOUTHOLD IN GRAVEL BASEI............... ; .......__..__ E 3.LOCATION OF DRYWELL TO BE DETERMINED BY OTHERS.THE DRYWELL SHALL BE 3970 NORTH BAYVIEW ROAD TOWN OF SOUTHOLD, SUFFOLK COUNTY, NEW YORK INSTALLED IN ACCORDANCE WITH ALL SUFFOLK COUNTY AND TOWN OF SOUTHOLD . ; • ` '•" '# #•, SOUTHOLD, N.Y. 11971 S.C.T.M. DISTRICT 1000, SECTION 079, BLOCK 02, LOT 3.3 WALL DETAIL CODES/REQUIREMENTS AND SHALL MAINTAIN ALL MINIMUM SEPARATION DISTANCES. SCHEMATIC PIPING ARRANGEMENT 4.ALL DRAINAGE PIPES MUST BE PROVIDED WITH A MINIMUM 2'-0"COVER. SCALE: 3/4"= V-0" NOT TO SCALE 5.COLLAR IS NOT REQUIRED WHEN RATEABLE MATERIAL EXISTS FOR FULL DEPTH. HM ENGINEERING P.C. 6.THE MATERIAL USED FOR COLLARING SHALL BE COMPRISED OF SAND AND GRAVEL , 1 NOTES: CONTAINING LESS THAN FIFTEEN(15)PERCENT FINE SAND,SILT AND CLAY.SILT AND 1.WALLS SHALL BEAR ON UNDISTURBED SOIL CLAY FRACTIONS ARE NOT TO EXCEED(5)PERCENT. ; /f/� P.O. BOX 914, EAST NORTHPORT, N.Y. 11731 2.ALL CONCRETE SHALL BE PLACED AS A MONOLITHIC POUR, V PHONE (516)476-5392 FAX(631) 980-7671 3.BACKFILL MATERIAL TO BE SAND,GRAVEL OR OTHER NON EXPANSIVE MATERIAL. DRYWELL CALCULATION: EMAIL: HMARNIKA@HMENGINEERINGPC.COM =THESE PLANS,SPECIFICATIONS,&DESCRIPTION OF DESIGN INTENT ARE THE INSTRUMENT OF DEVICE AND PROVIDE BACKWASH FROM POOL 70 GPM @ 5 MIN. 350(47 GAL. CF) /V (� (� 'Z PROPRIETARY INFORMATION EXCLUSIVE TO THE PROFESSIONAL SERVICES RENDERED FOR THE CLIENT LISTED ABOVE. THEY DAL.(47 CAPACITY=665 GAL.(89 CF) `SHALL NOT BE REPRODUCED,ALTERED,OR TRANSFERRED IN ANY MANNER FOR THE SAME OR SIMILAR PROJECT WITHOUT EN CONSENT OF THE ENGINEER, THEY SHALL REMAIN THE PROPRIETY PROPERTY OF THE HEREIN ENGINEER OF DRAWN BY: HM DRAWING NO.: RECORD,WHETHER OR NOT WORK DESCRIBED WITHIN THIS DOCUMENT AND ATTACHMENT IS CARRIED TO COMPLETION. THIS TRU COPIES HAVE DESIGN PROFESSIONALS DATE: OCTOBER 08,2023 WORK IS THE COPYRIGHT PROPERTY OF THE ENGINEER AND IS PROTECTED UNDER SECTION 102 OF THE COPYRIGHT ACT, AISED SEAL AND SIGNATURE IN BLUE �- 17 U.S.C. ANY UNAUTHORIZED USE AND/OR REPRODUCTION OF THE DRAWINGS SHALL BE PROSECUTED UNDER THE FULL EXTENT OF THE LAW. P.E.SEAL AND SIGNATURE SCALE: AS SHOWN SHEET NO.: OF