HomeMy WebLinkAbout50967-Z �oItStlFf01,f�OG Town of Southold 10/4/2024
CO
y P.O.Box 1179
o _ .} 53095 Main Rd
Southold;New York 11971
CERTIFICATE OF OCCUPANCY
No: 45401 Date: 7/26/2024
THIS CERTIFIES that the building GENERATOR
Location of Property: 8045 Nassau Point Rd,Cutchogue
SCTM#: 473889 Sec/Block/Lot: 118.4-8
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
4/10/2024 pursuant to which Building Permit No. 50967 dated 7/19/2024
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
accessory generator as applied for.
The certificate is issued to Katz M Revoc Trust
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO: 50967 6/24/2024
PLUMBERS CERTIFICATION DATED
th riz ignature
p�SUFFQl�cO TOWN OF SOUTHOLD
BUILDING DEPARTMENT
y x TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 60967 Date: 7/19/2024
Permission is hereby granted to:
Katz M Revoc Trust
494 Salem St
Paramus, NJ 07652
To:
install generator as applied for per Trustees approval.
At premises located at:
8045 Nassau Pointi Rd,Cutchogue
SCTM #473889
Sec/Block/Lot# 118.-4-8
Pursuant to application dated 4/10/2024 and approved by the Building Inspector.
To expire on 1/18/2026.
Fees:
ACCESSORY $125.00
ELECTRIC $100.00
{
CERTIFICATE OF OCCUPANCY $100.00
Total: $325.00
Building Inspector
pF SOUr�ol
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 G Q
sean.devlinitown.southold.ny.us
Southold,NY 11971-0959
CQUf
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Katz M Revoc Trust
Address: 8045 Nassau Point Rd city:Cutchogue st: NY zip: 11935
Building Permit* 50967 Section: 118 Block: 4 Lot: 8
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: Electrician: PKJ Electric License No: 60122ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement X Service
Commerical Outdoor X 1st Floor X Pool
New X Renovation 2nd Floor Hot Tub
Addition Survey Attic Generator X
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service'3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO
Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors
Disconnect Switches 4'LED Exit Fixtures Sump Pump
Other Equipment: 22kW Generac Generator w/200A Whole House Transfer Switch
Notes: Generator
Inspector Signature: Date: July 24, 2024
S. Devlin-Cert Electrical Compliance Form
OF SOOTyOlo r� 5 / " m'l TOA ��-
OF SOUTHOLD BUILDING DEPT.
°`y o►m��''�� 631-765-1802
INSPECTION '
[ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING .
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE.& CHIMNEY [ ] FIRE SAFETY-INSPECTION
[ ] FIREAESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS:
;rJAPA-Lz CO)
DATE INSPECTOR
FIELD INSPECTION REPORT DATE COMMENTS
v
D �
FOUNDATION (1ST) .z g
------------------------------------
C
FOUNDATION (2ND)
0- z
o
rI
ul
ROUGH FRAMING&
PLUMBING G
O
n
� r
INSULATION PER N.Y.
STATE ENERGY CODE
FINAL
ADDITIONAL COMMENTS
le
qCk it �Q5 re �080� 3
� Z
p A
Ile
ce
�x
� b
� O
z
x
x
d
b
gUfFO(K
��p�0 eGGy�2 TOWN OF SOUTHOLD—BUILDING DEPARTMENT
y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownn . ov
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only6qJ
no
PERMIT NO. l!l Building Inspector: i APR 1 0 2024 '
H ca L .
Applications and forms must be filled out in'their entirety:Ihcoinplete
applications will not be accepted:�Where the.Applicant'is not the owner,an
Owner''Authoriiatio,n form(Page 2)shall be completed., i:°', spa`r:s '' _#"`' `s
Date:
OWNER(S)'O•F PROPS TY:.., ;
Name' _._ ��� �_..`�.�__ ._ �.��._•.__-_I��� SCTM# 1000-
Project Address: �_ __ _ _�y_ ` _ J�-___._.Y_\C(._,. __Vl l S____
Phone#: _ L Email:
�� ________.-�-fit... __ _ _(�:.✓__1_.__..�_._ _r<__. o__.�___
Mailing Address:
CONTACT PERSON:
Name:
Mailing Address:
Phone#: Email:
DESIGN PROFESSIONALINFORMATION;
Name:
Mailing Address:
one#: _w.. n.ror,•s..k. ._5j Email:
'CONTRAC_TOR-.INFORMATION. -",
`Name`.
Mailing Address:
14
Phone#: Email.
DESCRIPTION-OF PROPOSED CONSTRUCTION.
❑NewStructu a ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
Other S $ I!;�- [DOO
Will the lot be re-graded? ❑Yes ENO Will excess fill be removed from premises? ❑Yes ❑No
1
-PROPERTY,-1NFORMATION
Existing use of property: Intended use of property: _
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? ❑Yes o IF YES, PROVIDE A COPY.
theck'Box,After-Reading:-The owner/iontrador/design.professional Is responsible"for all drainage and storm"water issues as provided by
Chapter�236 of the4TownXode�APPLICATION,IS HEREBY MADE to the Buildin-g Department for theis of a Building"Permit pursuant,to the Building zone,.
Ordinance of the Town,of Southold;•Suffolk,County,New York and other'applicable Laws,Ordinances or Regulations,,focthe construction of buildings,-,.
atldWong,alterations or',for'removal or demolition as herein described:The applicant agrees to comply.with all applicable laws,ordinances,building code,
;housing code and regulations and to admit authorized inspectors on premises and in bullding(s)for necessary inspections:False statements made'herein are
punishable*s a Class Axmisdemeanor.pursuant to Section 210AS of the New York State,Penal"Law. ,
Application Submitted ByA(print name): ��c 'LL ❑Authorized Agent POwner
Signature of Applicant- Date:
rw�+aey
STATE OF �)
SS:
COUNTY OFr��ea! )
069ML- A kA T71 being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)heisthe L/VV%_
(Contractor,Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of JU V-I'A
, 20
Notary Public
PROPERTY OWNER AUTHORIZATION ROBERT SHEH
applicant is not the owner Notary Public-State of New Jersey
Where the a
pp ) My Commission Expires Jan 23, 2026
I, residing at
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
Glenn Goldsmith, President ®F s®�/�� Town Hall Annex
®� 54$7.5 Route 25
A. Nicholas Krupski,Vice President a� ® P.O. Box 1179
Eric Sepenoski Southold, New York 11971
Liz Gilloy Q i 11 +��1V
Elizabeth Peeples L�
� : n
COUNII JUL 1 9 2024 "
BOARD OF TOWN TRUSTEES BUILDING DWr.
TOWN OF SOUTHOLD 'OWN'yFS T
OUTAOI�:
CERTIFICATE OF COMPLIANCE
#2155 C Date: July 16,2024
THIS CERTIFIES that the renovation of existing one story year residence(1,861 sfl•removal of existing first floor,
water side bay window structure(12 sf)at residence-,construction of new first floor addition(13 sfl to waterside of residence;
existing basement(1,694 s with grade access 2 car garage,below residence to remain,•construction of new second floor
addition(1,810 sfl over existing first floor residence;construction of new two story building addition(116 sfl to existing,
landward side of residence,• construction of new overhead exterior deck structure at waterside of residence 70 sf at second floor
level above first floor existing exterior deck structure construction of new covered entry porch and exterior stairs(260 sfl to
existing landward side of residence;construction of new entry deck(52 sfl to residence at waterside of existing residence,
removal of existing_entry stairs and patio(250 sfl at landward side of residence-removal of existing masonry stairs(16 sf)to
South side of residence existing waterfront deck(1,015 sf)adjacent to residence to remain-,installation of new hot tub(64 sf)
built into existing waterfront deck structure adjacent to existing residence;existing wood steps and landing(89 sfl from top of
slope at waterside of residence to deck structure adjacent to existing bulkhead to remain• existing deck structure(79 sfl at top of
existing bulkhead to remain existing beach stairs(39 sfl from top of existing bulkhead to beach to remainsinstallat"onofrnew
��20.kwY�enerator(�151sf1ronySouthpside of existing residence~existing exterior patio(383 sf)on South side of residence to remain;
construction of new exterior ramp(200 sfl on grade to existing landward side of residence existing retaining wall(33 lfl at
landward side of residence North side to remain,• installation of new IA OWTS sanitary system located at landward side of
residence North side of propel1y,•existing ravel driveway to remain• existing drywells for rainwater runoff from residence to be
verified for size and location additional drywells added if required for additional capacity and verify gutters to leaders to
drywells establishment'and maintenance of new 6 ft wide non turf buffer landward from the top of slope,
At 8045 Nassau Point Road Cutchogue
Suffolk County Tax Map#]000-118-4-8
Conforms to the application for a Trustees Permit heretofore filed in this
office Dated MU 13,2021 pursuant to which Trustees Wetland Permit#9969
Dated August 18,2021,and Amended on November 17,2021 was issued and conforms to all of the
requirements and conditions of the applicable provisions of law. The project
for which this certificate is being issued is for renovation of existing one story year residence(1,861 sfl;removal of
existing first floor,water side bay window structure(12 sf)at residence-,construction of new first floor addition(13 sf)to
waterside of residence-,existing basement(1,694 s with grade access 2 car garage,below residence to remain construction of
new second floor addition(1,810 sfl over existing first floor residence;construction of new two story building addition(116 sf)
to existing, landward side of residence;construction of new overhead exterior deck structure at waterside of residence 70 sf,at
second floor level above first floor existing exterior deck structure-construction of new covered entry porch and exterior stairs
(260 sfl to existing landward side of residence;construction of new entry deck(52 sfl to residence at waterside of existing
residence removal of existing entry stairs and patio(250 sfl at landward side of residence removal of existing masonry stairs
(16 sf)to South side of residence,•existing waterfront deck(1 015 sf)adjacent to residence to remain;installation of new hot tub
(64 sfl built into existing waterfront deck structure adiacent to existing residence•existing wood steps and landing(89 sfl from
top of slope at waterside of residence to deck structure adjacent to existing bulkhead to remain;existing deck structure(79 s at
top of existing bulkhead to remain.,existing beach stairs 39 s from top of existing bulkhead to beach to remain7 installation of
new 20 kw generator(15 sfl on South side of existing residence• existing exterior patio(383 sfl on South side of residence to
remain construction of new exterior ramp(200 sfl on grade to existing landward side of residence•existing retaining wall(33 If)
at landward side of residence North side to remain• installation of new IA OWTS sanitary system located at landward side of
residence North side of roe •existing ravel drivewa to remain;existing drywells for rainwater runoff from residence to be
verified for size and location additional drywells added if required for additional capacity and verify gutters to leaders to
drywells establishment and maintenance of new 6 ft wide non turf buffer landward from the top of slope.
The certificate is issued to MICHAEL KATZ&MELISSA KATZ AS TRUSTEES OF THE MELISSA KATZ REVOCABLE
TRUST owners of the aforesaid property.
Authorized Signature
�S�FFOL�. O BUILDING DEPARTMENT- Electrical Inspector
=�0 CGyt TOWN OF SOUTHOLD
N = Town Hall Annex - 54375 Main Road - PO Box 1179
^+ Southold, New York 11971-0959
oy,�p� Telephone (631) 765-1802 - FAX (631) 765-9502
jamesh southoldtownny.gov - seand@southoldtownny.aov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All information Required) Uil
Date: q/ 9
Company Name: CG6X'✓e- �. r ` .jC�
Electrician's Name: vh,
License No.: 14 4VZo 61 Elec. email:
Elec. Phone No: /Y/- 7/1/ 1 request an email copy of Certificate of Compliance
Elec. Address.: -1 t V,'644 jJ-r -;9Z7 vY T -e- 5Z, ff2v
JOB SITE INFORMATION (All Information Required)
Name: fp— 6- J4�, '--
Address: 16 L(S P , V � C- -�
Cross Street: 76 -,J l /L*,,�
Phone No.: Za Y P`2 -" -7 3 65
Bldg.Permit#: ��j- '' ;, `� email:
Tax Map District: 1000 Section: I Block: Lot:
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
G7
Square Footage:
Circle All That Apply:
Is job ready for inspection?: ® YES ❑ NO ❑Rough In ❑ Final
Do you need'a Temp Certificate?: ❑ YES F�71 NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 1 2 R H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
PROPOSED 14FA EXTERIOR .
LANDING AND STAIRS,52 sf
NEW BASEMENT EGRESS AREA WAY,IS of PROPOSED NEW BUILDING ADDITION,
NEW OUTDOOR SHOYM 24 of 19 ef,TO EXISTING RESIDENCE
EXISTING RESIDENCE,TO BE DEMOLISHED EXISTING BUILDING AREA TO BE
AND REPLACED WITH A NEW REMOVED.12 of,PROVIDE NEW
RECONSTRUCTED STRUCTURE, 1,994 ef, DECKING TO MATCH EXISTING
w HEW SECOND FLOOR ADDITION,1AO5 of
EXISTING DRYWELLS TYP VERIFY EXACT PROPOSED PE OVERHEAD EXTERIOR DECK STRUCTURE,TO SF,
LOCATION AND SIZE DURING CONSTRUCTION AND AT SECOND W FLOOR LEVEL,ABOVE FIRST FLOOR EXISTING
VERIFY GUTTERS TO LEADERS TO DRYNELLS
EXTERIOR DECK STRUCTURE
TOP OF SLOPE
PROPOSED NEW ADDITION, E5TING NON-TURF BUFFER ON SLOPE
DAD) - IIO sf,TO EXISTING RESIDENCE X
^(T'1J NV ATE1 LAME PROP05ED NE COV
ERED VERED ENTRY BOTTOM OF SLOPE
Y'R � 1P� — PORCH AND EXTERIOR STAIRS,294 s1 EXISTING NEIGHBORING VINYL BULKHEAD
CLE EXISTING RETAINING WALL 93 It EXISTING NElSF60PING WOOD GROIN
PROPOSED HEW IA OWTS SEPTIC 5YSTEM 1
FOR A 5 BEDROOM RESIDENCE 1 6 FT.WIDE(LANDWARD FROM TOP
N/0/F PROPOSED SILT FENCE AND HAY BAILS 17.1 , 1 N OF SLOPE)NON TURF BUFFER
PETER NOLLIS 1 DURING CONSTRUCTION SEE DETAIL yy¢xf v �. •I O HIGH WATER MARK ALONG BULKHEAD
publi.wat¢r _ .1 - 'a I,I WOOD CPP OVER VINYL BULKHEAD -
_ 15,WIDE EXISTING NON-TURF BUFFER
R N ALONG THE LANDWARD EDGE OF THE LITTLE
11'11111 19' A BULKHEAD-AS APPROVED BY TOWN
' TRUSTEES NOVEMBER 16,2011 PECONIC
E I BOTTOM OF SLOPE BAY
N 82700�00" ••a` 11.71n" ," _ ;r,=.� �1i.11 1 EXISTING BEACH STAIRS TO REMAIN,99 sf
— Xm_ ."Doypyps�0� RBIE'; �,.ate•, EXISTING WOOD STEPS(9k25b)AND UPPER LANDING(3k49 TO REMAIN,b9 sf
i .'pNmvs�•.'
' W.6ARA6 ( ��„ 1 I III I 1 EXISTING DECK STRUCTURE(•Ikl3T TO REMAIN,91 01,
OImDi :I ,,=.,lu b' 1 STAIRS NOT BUILT ON DECK '
z A61'`f I'` TOP OF SLOPE
y — F� 2,5, BUFFER LOCATION MAP
pRpry�r �___ GR;l6.7$ 6 B'WIDE EXISTING E LAN A
�/1�� EDGE OFF THE BULKHEAD-AS
public water s 1 APPROVED BY TOWN TRUSTEES
NOVEMBER Ib,2011
�,•i �'� •• - ,;• •. C. b FT WIDE(LANDWARD FROM TOP .
®a OF SLOPE)EXISTING GROUND
D e 16 COVER PLANTS TO REMAIN,NON
I..d ,on;sn_6c o,�,+":•.— � � � �Da .1— 1� �1..1 1 TURF BUFFER
y '.. .I 3 2.• u "EXISTING NEIGHBORING FIBERGLASS
O FII' 1�• —_ - e CAP OVER VINYL BULKHEAD t
6 1nuR'ras- BOTTOM.OF SLOPE \t
{� NSW UND E EXISTING NON-TURF BUFFER ON SLOPE
outim
tR ��� T� TOP OF SLOPE `
o I —.fix`°
O t18ce2 EXISTING EXTERIOR STAIRS AND '.NFYi:OUTDOOR GEfERAYOR "
RETAININ64'WL-L-TO-BE-REMOVED
TTO"�'•`•" a'i _ PROPOSED NEW HOT TUB B
— — - -E- �_�• DECK STRUCTURE 8 FEET SWARM,
64 sr ,
__-__--._O_._.•' ___5 BYOOrDDn W '� NEW EXTERIOR RAMP ON GRADE S BE RB%IOVIED,Ib et "EXISTING DRYWELLS TTP VERIFY EXACT
- EXISTING EXTERIOR PATIO ON -LOCATION AND SIZE DURINS CONSTRUCTION AND SITE
1� GRADE TO REMAIN,9B3 of
y VERIFY GUTTERS TO LEADER*TO DRYMELLS
�I PROPOSED NEW ADDITION TO -
lJ N/0/F - EXISTING RESIDENCE,94 of PROPOSED SILT FENCE AND HAY BAILS ���� D���
e
JONN F.ALO/A EXISTING FIRST FLOOR WILDING STRUCTURE NUKING CONSTRUCTION SEE DETAIL .1
A:ELVlRA T.ALOIA TO BE DEMOLISHED AND REPLACED WITH A sel.0
public waI" SITE PLAN HEN RECONSTRUCTED STRUCTURE, 153 1000.11sAd
PROPERTY: B065N11.SAU POIN ROAD
L.. �1 EXISTING FIRST FLOOR WILDING STRUCTURE . CUTCHOSUE.NY 11935
SCALE:I"-ZO-0' • TO BE DEMOLISHED, 12 of APPROVED BY O HER: MlnNel Kate mtl Malisaa KeQ
EXISTING EXTERIOR DECK STRUCTURE BOARDOFIRUSTEES eo Trustees o/Ua Nelkea Keu
TO REMAIN WITH NEW DECK TOWN OF SOUTHOLD Revocable Trust
SURFACING AND NEW STAIRS,693 of E: 39.890 s1-0.916ae,lo hl9h enter mark
EXISTING EXTERIOR DECK STRUCTURE DATE N¢V611W 177y21 Z NINO: R40
AND STAIRS TO BE REMOVED,152 sf RVEYOR: Nothnn T9R Comm 111
PO ben 16
/666 Maln Roatl
Uam9seorl.Nm York 11947
LiCEN5E 060a67
DATED=2021
KATZ RESIDENCE
' •� CUTCHOGUE, N y
DATE:5 11212021
REVISED:10 14 12021 Oi dl
ORAL TALGAT
ARCHITECT
❑aaT FENEDETAILS
43 , STREET
JEENPORT NEWOR 119
(631)477-8963 Di7111t11
VP PO ED AS NOTED
I,EE l 0 6 6 BY -
WITIFY BUILDING DEPARTM T AT
631-765.1802 8AM TO 4PM FOR THE
FOLLOWING INSPECTIONS:
1. FOUNDATION-TN`^RFO?
FOR POURER CONd{;I=1�. '
2 ROUGH—FRAMING& ELECTRICAL
3. INSULATION INSPECTION REQUIRED
4. FINAL-CONSTRUCTION MUST
BE COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTON ERRORS
COMPLY WITH ALL CODES OF
NEW YORK STATE&TOWN CODES
AS REQUIRED AND CONDITIONS OF
SOUTHOLD TOWN TRUSTEES
Soffam
DID--
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICA*
OF OCCUPANCY
GENERAC®
GUARDIAN° SERIES
16/20/22 kW -
idential Standby Generators
51(�;Vays Air-Cooled Gas Engine
n 424
JUL INCLUDES: J Standby Power Rating
035-1,G007036-1,G007037-1(Aluminum-Bisque)-16 kW 60 Hz
BU�'
• True Power'" Electrical Technology *�D� F!G D*VV —.`G007042-10,G007043-10(Aluminum-Bisque)-22 kW 60 Hz
G007038-1,G007039-1(Aluminum-Bisque)-20 kW 60 Hz
• Two-line multilingual digital LCD Evolution"'controller Q Q
'"
(English/Spanish/French/Portuguese) ,�• � _
• Two transfer switch options available:
100 amp,16 circuit switch or - 9
200 amp service rated smart switch
• Electronic governor
Zi
• Standard Wi-Fi"connectivity available on 16kW and 20kW-1 models ,
and 22kW models
• System status&maintenance interval LED indicators ' GENERAC'
• Sound attenuated enclosure
• Flexible fuel line connector !.:
• Natural gas or LP gas operation
• 5 Year limited warranty Product shown with optional fascia kit
• Listed and labeled by the Southwest Research Institute allowing
installation as close as 18 in(457 mm)to a structure." COus or C �L OS Q / ry . ire
Mu t be located away from doors,windows,and fresh air intakes and in LISTED V
accordance with local codes. Note:CETL or CUL certification only applies to unbundled units and units
hMps:llassets.swri.org/librarylDirectoiyOfListedProducts/ ppackaged with limited circuit switches.Units packaged with the Smart Switch are
Constructionindustryl973 DoC 204_13204-01-01 Rev9.pdf ETL or UL certified in the USA only.
FEATURES
O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod-
Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI-
the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge
rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%.
O TRUE POWER-ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small-
allows confident operation of sensitive electronic equipment and micro-chip based est electronic component.
appliances,such as variable speed HVAC systems.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with
✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system
compatibility.
O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby
generators,Mobile Link Wi-Fi allows users to monitor the status of the generator
from anywhere in the world using a smartphone,tablet,or PC.Easily access informa-
tion such as the current operating status and maintenance alerts.Users can connect
an account to an authorized service dealer for fast,friendly,and proactive service.
With Mobile Link,users are taken care of before the next power outage.
�IPR0MISE Q ®' '
GENERAC*
16/20/22 kW Features and Benefits
Engine
• Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly
rings help the engine run cooler,reducing oil consumption and resulting in longer engine life.
• "Spiny-lok"Gast iron cylinder walls Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance These features combine to assure smooth,quick starting every time.
• Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine
' life.Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown Prevents damage due to overheating.
Generator
• Revolving field Allows for a smaller,lightweight unit that operates 25%more efficiently than a revolving armature generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability.
• Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes.
• EPA Certified for non-emergency applications Allows unit to be used for demand response applications(applicable to 22 kW units).
• UL 2200 listed For your safety.
Transfer Switch(if applicable)
• Fully automatic Transfers vital electrical loads to the energized source of power.
• NEMA 311 Can be installed inside or outside for maximum flexibility.
• Remote mounting Mounts near an existing distribution panel for simple,low-cost installation.
Evolution- Controls
• AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition.
• Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences.
• Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations.
• Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage.
• Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home.
• Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds.
• Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute.
• Programmable exercise Operates engine to prevent oil seat drying and damage between power outages by running the generator for
5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
• Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
• Main line circuit breaker Protects generator from overload.
• Electronic governor Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding
winds up to 150 mph(241.km/h).Hinged key locking roof panel for security.Lift-out front for easy access
to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries.
• Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure.
GENERAC
16/20/22 kW Features and Benefits
Installation System
• 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
• Integral sediment trap Meets IFGC and NFPA 54 installation requirements.
Connectivity(Wi-Fi equipped models only)
• Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for
complete peace of mind.
• Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
• Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due.
• Monthly report with previous month's activity Detailed monthly reports provide historical generator information.
• Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
• Weather information Provides detailed local ambient weather conditions for generator location.
GENERACA
16/20/22 kW Specifications
Generator
_ Model 16 kW 20 kW 22 kW
Rated maximum continuous power capacity(NG) 16,000 Walls' 18,000 Walts' 19,500 Watts'~_
Rated voltage-`�`----�__
Rated maximum continuous load current-240 volts(LP/NG) _ �66.7/66.7 83.3/75.0 91.7/61.3_
Total Harmonic Distortion
r Main line circuit breaker 70 amp -u T� 90 amp 100 amp
Phase _ __._-,_.__ _.__ ___._ ___ _._..._._._ __ _..r __.._ __ .__ w.n .:— -- - 1
Number of rotor poles µ 2 _
Rated AC frequency
Power factor _ ~1.0 _
BI Battery requirement(not incfuuded)�'�- _ w- � 12 Volts,Group.26R'540 CCA minieum ar Group 35AG_M 85D CCA minimum- �I
Unit weight(Ib/kg) �409/186 - 448/2203 466/211
Dimensions(LxWxHjin/cm_—' 48x25x29/121.9xfi3.5x73.7
Sound output in dB(A)at 23 it(7 m)with generator operating at normal load" �67 67 67_
[Sound output in dB(Cat 23 tr(7 m)_with generator in Quiet-Tesi'"low-speed exercise mode"_ '55 _ — �757--
Exercise duration 5 min
Engine
Engine type _ _ GENERAC G-Force 1000 Series
Displacement _ 999 cc
(Cylinder block _. ���� _�_ y _ Aluminum w/cast iron sleeve y � j
Valve arrangement Overhead valve _
Solid-stale w!magneto
Governorsyslem _ _ _ _ Electronic
[ompressien ratio.
Starter 12VDC
Oil capacd mcludfng filtei
Operating rpm 3,600
Fuel consumption
Natural gas W/hr(m3/hr)
1/2 Load 218(6.17) '204(5.78), 228(6.46)
Full Load ] 309(8.75) 301(8.52) 327(9.26)
Liquid propane fta/hr(gaVhr)Mr]
y 1/2 Load 74(2,03)[7.70] 87(2.37)[8.99]. 92(2.53)[9.57]
1 _ Full Load _ 107(2:94)111.1.11 130(3.56)[13.481 142(3.90)[14.771
Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.
For BTU content,multiply fl3/hr x 2500(LP)or ft3/hr x 1000(NG).,For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG).
Controls
Two-line plain text multilingual LCD Simple user interface for ease of operation.
Automatic start on utility Failure.7 Cay i:xnrcis r_.
MANUAL _ v Start with starter control,unit stays on.It utility fails,transfer to load takes place.
—W__a___�Siops unit.Power is removed.Control and charger still operate. ���
Ready to Run/Maintenance messages Standard wT
Enginene run hours indindication
Programmable start delay between 2-1500 seconds Standard(programmable by dealer only)
(Utility Voltage LosslRelurn to lhilily adjustable(brownout selling)"_ l �y From 140-171-V/190 211iV �L _ �
Future Set Capable Exerciser/Exercise Set Error warning ��—Standard
Engine start sequence yCyclic cranking:16 sec on,7 rest(90 sec maximum duration). -
Starter lock-out � _S_tar[er cannotre-engage unfit 5 sec alter engine has stopped,
Smart Battery Charger _ __ _ __ - _Standard
[Chagor Standard_� � � roF�
Low Battery/Battery Problem Protection and Battery Condition indica0on Standard
Automatic Voltage Regulation.w th Over and UndehVoltege Protection _ p Standard
Under-Frequency/Overload/Stepper Overcurrent Protection _ Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard-
�Overcrarik%Overspeed
High Engine Temperature Shutdown Standard
Internal FaulUlncorrect Wiring protection- �- ���� _ ��_ Standard
Common external fault capability Standard
Field up ratlahle6riYlvrdre
d_._. g fda6I_.._._.___w _ _.. __._ �__ _ _ ._
Rating definitions-Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed.No overload capability is available for this rating.(Ail
ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271).
.Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases
approximately 3.5%for each 1,000 it(304.8 m)above sea level;and also wflI decrease approximately 1%for each 10`F(6°C)above 60`F(16`Q.
"'Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.
GENERAC
16/20/22 kW Switch Options
Limited Circuits Switch Features Model G007036(16kW)
No.of poles _2
• 16 space,24 circuit,breakers not included. Current rating(amps) 100
• Electrically operated,mechanically-held contacts for fast,positive connections. Voltage rating(VAC) _120'/2 00,10� w
• Rated for all classes of load,100%equipment rated,both inductive and resistive. Utility voltageoltage monitor(fixed)" 80`Yo
• 2-pole,250 VAC contactors. -Dropout 65%
• 30 millisecond transfer time. Keturri to'Utility"" - _Approx.l5 eec __ #
Exercisesbi-weekly for 5 minutes` Standard
• Dual coil design. P-----Listed - - ---- — ,
,�ETL or UL Listed ��- Y_Standard_______�3
• Rated for both copper and aluminum conductors. Total circuits available _ 24
• Main contacts are silver plated or silver alloy to resist welding and sticking. Tandem breaker capabilities 8 tandems
• NEMNUL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting Circuit breaker protected ____
flexibility. Available AMS symmetrical 10,000
fy. Fault current @ 250 volts
• Multi listed for use with 1 in standard,tandem,GFCI and AFCI breakers from Siemens, *Function of Evolution controller
Murray,Eaton,and Square D for the most flexible and cost effective install. Exercise can be set to weekly or monthly
Dimensions
Height Width
H1 H2 Wi W2 Depth
rp H7
in 26.75 30.1 10.5 13.5 6.91
cm 67.95 76.45 26.67 34.29 17.55
Wire Ranges
Conductor Lug Neutral Lug Ground Lug
1/0-#14 2/0-#14 2/0-#14 a � �
Service Rated Smart Switch Features Model 6007037(16 kW)/G007039(20 kW)/
G007043(22 kW)
• Includes digital power management technology(DPM)standard. No.of poles __ ° 2 ~�
• Intelligently manages up to four air conditioner loads with no additional hardware. Current rating(amps) 200i
• Up to eight additional large(240 VAC)loads can be managed when used in %Voltage rating(VAC) 120/240,113 -�_
conjunction with Smart Management Modules(SMMs). Utilityvoktage monitor(fixed)"
-Pick-up 80%
• Electrically operated,mechanically-held contacts for fast,clean connections. -Dropout 65%
• Rated for all classes of load,100%equipment rated,both inductive and resistive. I Return to Utility' Approx_
• 2-pole,250 VAC contactors. Exercises bi-vreekly for 5 minutes` Standard
ETL orr eL Iisted Standard r
• Service equipment rated,dual coil design. Enclosure type NEMA/UL 3R
• Rated for both aluminum and copper conductors. �C ri uit breaker protected _ 22,000
• Main contacts are silver plated or silver alloy to resist welding and sticking. cog range -� 250 MGM-#6
*Function of Evolution controller
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting Exercise can be set to weekly or monthly
flexibility. w�
Dimensions
Height Width Depth
H1 H2 W1 W2
in 26.75 30.1 10.5 13.5 6.91
cm 67.95 76.45 26.67 34.29 17.55
Wire Ranges
Conductor Lug Neutral Lug' Ground Lug °
350 MCM-#6 350 MCM-#6 2/0-#14 0�'" WW2--�
GENERAC"
16/20/22 kW Available Accessories
Model# Product ' Description
6005819-0 2611 Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery;
for use with all air-cooled standby product(excluding PowerPact ).
G007101-0 i Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(-18 IC).(Not nec
essary for use with AGM-style batteries).
G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0 OF(-18°C).
6007103-1 Breather Warmer Breather warmer is for use In extreme cold weather applications. For use with Evolution controllers only in climates
where heavy icing occurs. f1
G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may noi{
Contact Kit f be needed.Not compatible with 50 amp pre-wired switches.
G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,-- contoureo
appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base.
G005703 0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched ordamaged,it is importantto touch up the paintto protectfrom future corrosion1
The touch-up paint kit includes the necessary paint to correctly maintain ortouch up a generator enclosure. 1
G006485-0 !Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on ;
Generac automatic standby generator(oil not included).
G007005 0Wi Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring
Monitor the LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.1
Status alerts are available through a free application to notify users when the LP tank is in need of a refill.
600700D-0(50 amp) ;Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.They manage anage large
G007006-0(100 amp) electrical loads upon startup and shed them to aid in recovery when overloaded.In many cases,using SMM's can re I
duce the overall size and cost of the system.
G007169-0 Mobile Link®4G LTE Cellular The Mobile Link 4G LTE Cellular Accessory allows users to monitor the status of the generator from anywhere in the
Accessory world,using a smart phone,tablet,or PC.Easily access information such as the current operating status and mainte
nance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proactive
With Mobile Link,users are taken care of before the next power outage.
6007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured
appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit9
contains four plugs,sufficient for use on a single air-cooled home standby generator.
Dimensions & PCs
Model UPC 6375 mm [480in)
G007035 696471074161 125.7 in]
G007036 696471074154
G007037 696471074178
G007038 696471074185
G007039 696471074192
0007042 696471074208 727.2 mm
[2.6 in)
G007043 696471074215
0 I Oil
I It
648 mm 1232 mm
[25.5 in] 148.5 im
LEFT SIDE VIEW FRONT VIEW
Dimensions shown are apprwdmate,See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
GE N E RAC Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com
02022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.10000000194 Rev.L 03/24/2022