Loading...
HomeMy WebLinkAbout51323-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51323 Date: 10/29/2024 Permission is hereby granted to: Brett B Dohnal 813 Dean St Apt 2 Brooklyn, NY 11238 To: construct deck addition, outdoor shower and interior alterations to existing single-family dwelling as applied for per Trustees and DEC Non-Jurisdiction letter. Premises Located at: 1225 Long Creek Dr, Southold, NY 11971 SCTM# 55.-3-29 Pursuant to application dated 09/13/2024 and approved by the Building Inspector. To expire on 10/29/2026. Contractors: Required Inspections: Fees: Single Family Dwelling- Addition&Alteration $609.50 CO-RESIDENTIAL $100.00 Total $709.50 g Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 ryw Telephone (631) 765-1802 Fax (631) 765-9502 htt ://e °.so lhoidtomqul . v pate,,F; eived 'PLC T BIILIIIC IIII� C17-111, For Office Use Only .� PERMIT NO. Building Inspector: SEP 1 3 202 F Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an ' ..� Owner's Authorization form(Page 2)shall be completed. " Date:September 10th, 2024 OWNER(S)OF PROPERTY: Name:Kim Dohnal SCTM#1000-55.-3-29 Project Address: 1225 Long Creek Drive, Southold, NY 11971 Phone#:(917) 941-1921 Email:kimmkramer@gmail.com Mailing Address: 1225 Long Creek Drive, Southold, NY 11971 CONTACT PERSON: Name:Jake LaChapelle AIA Mailing Address: P.O. Box 1251, Mattituck, NY 11952 Phone#:(646) 251-5058 EEmai1:jake@lachapeIlearchitecture.com DESIGN PROFESSIONAL INFORMATION: Name:Jake LaChapelle AIA Mailing Address:P.O. Box 1251, Mattituck, NY 11952 Phone#:(646) 251-5058 Email:jake@iachapeIlearchitecture.com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure EEP4dclition SiAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $15,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? Dyes @No 1 PROPERTY INFORMATION Existing use of property:Single-family residential Intended use of property: no Change Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? Eyes WNo IF YES, PROVIDE A COPY. lJ Check BOX After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print na ) Jak LaChapelle AIA RiAuthori2ed gent Downer Signature of Applicant- Date: � STATE OF NEW YORK) a S: COUNTY OF ' ° i)t k)�„) Jake LaChapelle being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the agent (Contracto A�o4 porate Officer, etc.) of said owner or owners, and is duly authorized to pehave performed the said work and to make and file this application; that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me thhis��,^ I Lday of �!�I VLJI-r , 20_ tary Public TRACEY L. DWYE:R PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC,STATE OF NEW YORK NO.01 DW6306900 (Where the applicant is not the owner) QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2a(p Kim Dohnal residing at 1225 Long Creek Road Southold, NY 11971 do hereby authorize Jake LaChapelle to apply on my behalf t the Town of Southold Building Department for approval as described herein. I wner's� la re Date Kim Dohnal Print Owner's Name 2 �µ NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATI0I4",�, r Division of Environmental Permits,Region 1 SUNY @ Stony Brook,50 Circle Road,Stony Brook,NY 11790 >a P:(631)444-0365 1 F:(631)444-0360 www.dec.ny.gov LETTER OF NO JURISDICTION: TIDAL WETLANDS ACT& NOTIFICATION OF POSSIBLE ENDANGERED SPECIES ACT JURISDICTION March 25, 2024 Kim Dohnal 813 Dean Street-Apt 2 Brooklyn, NY 11238 Re: Application #1-4738-04996/00001 Dohnal Property: 1400 1225 Long Creek Drive, Southold 11971 SCTM# 1000-55-3-29 Dear applicant: Based on the information you submitted, the Department of Environmental Conservation has determined that the portion of the property located landward of"top of bluff', as shown on the survey prepared by Harold F. Tranchon Jr., last revised January 3, 2024, is beyond the jurisdiction of the Article 25 Tidal Wetlands Act. Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661), no permit is required to conduct regulated activities landward of that contour. Be advised, no construction, sedimentation, or disturbance of any kind may take place seaward of the tidal wetlands jurisdictional boundary, as indicated above, without a permit. It is your responsibility to ensure that all precautions are taken to prevent any sedimentation or disturbance within Article 25 jurisdiction which may result from your project. Such precautions may include maintaining adequate work area between the jurisdictional boundary and your project (i.e. a 15' wide construction area) or erecting a temporary fence, barrier, or hay bale berm. Please be advised that DEC has documented the summer occurrence of the Northern Long Eared Bat (NLEB) (Myotis septentrionalis), a species listed as "endangered" by both New York State and the US Fish & Wildlife Service, within 3 miles of the project location. We have determined that tree cutting at this location between March 1 and November 30 of any calendar year may result in the "take" of these endangered/threatened species or their habitat within the meaning of Environmental Conservation Law (ECL) §11-535. The term "take" is defined in part as the direct killing or injury of individual members of a protected species, interference with critical breeding, foraging, migratory or other essential behaviors, or the adverse modification of the species' habitat. The "take" of a species listed as endangered or threatened is prohibited in the absence of a permit from this Department issued pursuant to ECL §11-535. In order to avoid an Endangered Species "take," no tree NEEW Depa ardent of YORK TATEEnvironmental Conservation cutting activities may be conducted at the project site between the dates of March 1 and November 30 of any calendar year. If you have questions about the presence of protected species on or near your property, the potential effects of activities on these species or your responsibilities as a landowner or project sponsor under the Endangered Species Regulations, please contact the Regional Wildlife Manager at (631) 444-0310. This letter shall remain valid unless site conditions change. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. Sincerely, Zerdi Richer Regional Permit Administrator cc: Cole Environmental Services BMHP File 23-212 i acres) 24-31 ( 0.51 ACRES ) �� ��.PIZ 'AT1O and STOOP = 2,004 SQ_FT_ )_FT_ DMDED BY 22,231 SQ.FT. = 9% SHOWER and WALK = 794 SQ.Ff " 00 (tobe removed) = 624 SQ_FT. =2.8% flo/1'4 =11.8% p � o D'IAIARD L1MIT'S OF TIDAL WETLANDS�0 AS FLAGGED BY COLE ENVIRONMENTAL SERVICES o ON 12/06/2023 FD1 " ofl�. MON 0A, I proposed" (� G� field stone w pebble b e wolk"� _, z �w`ce and gate O 0\ 1 30 O e gate proosed oa�tdoor O slower O UFFER. t 'X5.3' DEPENDENT Ul —� NTED AS NEEDED" ' O ]4.8' r— O O V ZCn ° o Z n (b C �7 Crt \ � co .� I m Sao ev <5er �« ITl O roofed oo rover � 9 7'x,3 m j 15.2' 15.7' * , N n D 15.9' ale GI ' p O 2 trey 2 $T!( 16.0' asphalt = existing elevations typical ] " drive z 15.5' 15.1' / O � O 00+ MON 15.4 15.6' _ 0P o pole N� 15.0' -� 10 mow' 14.3' 13.7' 1 Glenn Goldsmith, President Town Hall Annex �6 A. Nicholas Krupski,Vice President ,� 54375 Route�P.O.Box 1179 Eric Sepenoski Southold, New Yo k 11971 Liz Gillooly Telephone(631) 7 159 Elizabeth Peeples � �► �„�► Fax(631) 7 41 roue BOARD OF TOWN TRUSTEES �I TOWN OF SOUTHOLD Permit No.: 10639A F Date of Receipt of Application: May 3, 2024 Applicant: Brett & Kim Dohnal SCTM#: 1000-55-3-29 } Project Location: 1226 Long Creek Drive, Southold Date of Resolutionlissuance: July 17, 2024 Date of Expiration: July 17, 2027 Reviewed by: Board of Trustees Project Description: To remove existing rear slate patio; construct a ±12.8'x55' irregular rear deck using wood or composite, 50 cubic feet to excavated for' deck footings; steps on north side of deck to lead to ±16'x6' 'ebble walk at grade with surrounding 4' fence and ±6'x5.3' outdoor shower; pebble walk to continue under outdoor shower; establish and perpetually maintain a on-turf buffer planted with native, non-fertilizer dependent vegetation seaward of deck; establish and perpetually maintain a non-disturbance buffer from, top of bank seaward.. Findings: The project meets all the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code. The issuance of an Administrative Permit allows for the operations as indicated on the site plan prepared by Harold F. Tranchon Jr. P.C., received on September 9, 2024, and stamped approved on September 18, 2024. I Special Conditions: None. 1 Inspections: Final Inspection. If the proposed activities do not meet the requirements for is uance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code, a Wetland Permit will be required. i This is not a determination from any other agency. �r Glenn Goldsmith, President Board of Trustees "`��� � �-\�`� .`,� - �. � -,_� .t `„_ �� tic. \�� � -�.` �� ���\� � �� y\��� .� �_��\��� ��\off\��� - � �-����� �`�� .� ����\ �� � � � ���� �������d � �� � � �� � _ � �� �\ � �� �� ���, `\���_ �_� ���� �� - _� � ��� �A� �� ti\ `������ �� �� �� ��� _ ��, ��- _ s _ � - �- � _ - � o �_����` � ���� _. —-z - ���—� �� ti ����1 � �� � _ v - ,- �r_ - �� � � � _ � _ _ t �� _ �_ _ -- ,� � _ _ ���`_� � � � � �� �� � ���-z� �- � �� _��\�\\ ��\� � Doti\\� ���_� �����\\�0���\ x b LOT AREA = 24,199 SQ. FT. (0.556 acres) DATUM N.A.V.D. 1988 UPLAND LOT AREA = 22,231 SQ.FT. ( 0.51 ACRES ) , ✓" EXISTING LOT COVERAGE = HOUSE, PATIO and STOOP = 2,004 SQ.FT. ' 2,004 SQ.FT. DIVIDED BY 22,231 SQ.FT. = 9% r 0 PROPOSED LOT COVERAGE = DECK, SHOWER and WALK = 774 SQ.FT. ,0 ° ra LESS 170 SQ.Fr. FOR PATIO (tobe removed) = 604 SQ.FT. =2.57. o �' o 8a14 TOTAL UPLAND LOT COVERAGE =11.8% DWARip Limas off'nL ry0 AS FLAGGED BY COLE E v ON 12, P6,,/ a FD ' �of MO 6A proposed' � Cn G� field :tame sling p Isle a rwa0k� _. O�G land��f,,n e and O ate p outropdosedoor +� _ stlawrer c NON—DISTURBANCE6 14 5' rn BUFFER1 3' r NON—TURF" Z C MEAN LOW WATER LINE a BUF F1:R C 12 21— 023 \ +S" " r (MLw roofed over rn stoo 1 t ' 70 MEAN HIGH WATER LINE �" 15.9' 4h. 12-21-2023 / Cw wti r (MHIA) ,, y 5 2' r SC,ST g, N r N r �, / 15.9"' P ole SA r O O la I3 . 1 62 tree 15.9' 16.0' � STIC asphalt S�f1C existing elevations ti °�'„� �� 2 � 15.6"� drive -. aq / ✓ 1 n "1 d \15.44 15.6' aD pole 00 ," C).331 15.0' A Ile, BO) TOM sTK DATE -D ot I Town Hall Amex Glenn Goldsmith, President o � � 5 54375 Roush 25 A. Nicholas Krupski, Vice President +� P.O. Box 179 Eric Sepenoski i Southold, New York 11971 Liz Gillooly Telephone (631)j765 1892 Elizabeth Peeples Fax(631) 76 .6641 Nv BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD SOUTHOLD TOWN BOARD OF TRUE EES it YOU ARE REQUIRED TO CONTAC T THE OFFICE OF THP BOARD OF TRIU STEES 72 HOURS PRIOR TO COMMENCEMENT OF THE ACTIVI IES CHECKED 0, FF f BELOW INSPECTION SCHEDULE Pre-construction, hay bale line/silt boom/silt cuain 1st day of construction '/2 constructed When project complete, call for compliance inspection; I i ii LOT AREA = 24,199 SQ. FT. (0.556 acres) 23-212 24-31 DATUM NAV.D. 1988 24-63 UPLAND LOT AREA = 22,231 SQ.FT. ( 0.51 ACRES ) EXISTING LOT COVERAGE = HOUSE, PATIO and STOOP = 2,004 SQ.FT. , 2,004 SQ.FT. DIVIDED BY 22,231 SQ.FT. = 9% PROPOSED LOT COVERAGE = DECK, SHOWER and WALK = 774 SQ.FT. LESS 170 SQ.FT. FOR PATIO (tobe removed) = 604 SQ.FT. =2.5% ( 6 14 TOTAL UPLAND LOT COVERAGE =11.8% �i `*. DWARD LIMITS OF TIDAL WETLANDS 0 AS FLAGGED BY COLE ENVIRONMENTAL SERVICES ON 12/06/2023 FD) `5 of1j MON `V PmPo—d Cn G� 7 ring and° te v� 3woproposed outdoor —. "PROPOSED NON—TURF BUFFER. r 6*x5.3, C C"I NATIVE NON—FERTILIZER DEPENDENT VEGETATION TO BE PLANTED AS N 14.8' fll 0 (hatched a ) t 13.3' I— 0 1 � , 14,7'``�, S O Cn MEAN LOW WATER LINE O FO C W 12-21-2023 ,+ 1bW Rl (MLW) I ,° C c Cu M O roofed over rrI stoop tB, 7'x3' �7 MEAN HIGH WATER LINE < 12-21-2023 15.9' nl (MHW) , (b.IV 15.2' f- 15.7` C pole 0 I7 ' STK 5.9 f ` as halt STK 16.0' existing elevations typical - Z 1 16 P drive Z Q t)- at �` � CV 15 a' L�d � t--, 10 / 15.1' `L MON _co / pole CO O 0.33 0 / g S 14.3' / 137 11C `` ✓ / . ' �12.8' Cg,E 54_ 2 bob 12.4 �O14 G 15 bob 12. ' 0 Gp.N NOW �15A 0�55,4,11 1M PAK\Jls 00 MPX 4-23-2024 REVISED PROPOSED DECK P10,11 s & 3-1-2024 REVISED PROPOSED DECK p,LLk-1` 12-21-2023 REVISED, ADDED TOPOGRAPHICAL INFOMATION, PROPOSED NOW DECK and SHOWER INE OFFSETS(OR DIMENSIONS)SHOWN HEREON FROM 7HE s7RUaaxes TO THE PROPERTY LNES AM FOR A SPE RC PURPOSE AND USE AND 7HEREFORE ARE NOT JOB No. 23-40 FILE No. YENNECOTT PARK INTENDED TO GUIDE THE ERECRON OF FENCES.RETANNG WMiS.POOLS. PATIO. PLANING AREAS.ADDITION TO DULDOM OR ANY OTHER CONSTRUCTION. SURVEYED FOR KIM DOHNAL UNM"HDRMED ALTERATION OR ADDRION TD 7IDS SURVEY IS A VKU7IDN OF SECnON LOT NUMBER 13 7=OF IME NEW PORK STATE EDUCATION LAW. MAP OF YENNECOTT PARK GLMNANMM INDICATED HEM SN&L RUN ONLY E PERSON FOR WHOM IME TO THE SURVEY 6 PREPARED.AND ON HIS BEHALF 70 THE BILE COMPANY.GOVERNMENUL SITUATED AT SOUTHOLD AGENCY AND LF?IDNG INS1DUTION USIM HEREON.AND 7O THE ASSIGNEES OF THE LErwwG INSQTUTION.GUARWnM3 ARE NOT TRANSFERNLE TO A nIONAL NSTnUIOONS TOWN OF SOUTHOLD, SUFFOLK COUNTY.N.Y. OR SUBSDgUENT OWNERS. cmm OF Tm suRVer mw Nor BEMTNG im LArm suRvtYWs mm sm oR SCALE 1' = 30' DATE 4-3-2023 EMBOSSED SEAL SML NOT BE CONSIDERED TO SE A VAM TRUE COPY FILED MAP No. 518E DATE 10-9-1968 CERTIFIED ONLY TO: TAX MAP No. 1000-55-3-29 DISK 2023 �OF F HAROLD F. TRANCHON JR. P.C. LAND SURVEYOR i fa P.O. BOX 616 1866 WADING RIVER—MANOR RD. WADING RIVER, NEW YORK, 1T792 1-2 HAROL TRA` O JR Nil No. 048992 631-929-4695 C. No. 2115—E DOHNAL SS�Ss�I�-S RESIDENCE 1225 LONG CREEK DRIVE 1225 LONG CREEK DRIVE 3 SOUTHOLD,NY 11971 SOUTHOLD, NY DECK ADDITION DRAWING LIST A1.00 DRAWING LIST,ABBREVIATIONS,SYMBOLS, &NOTES SCTM#-1000-55.-3-29 A2.00 NOTES&ENERGY CODE COMPLIANCE A3.00 SITE PLAN A4.00 DECK PLAN A5.00 DECK DETAILS TAX MAP NO.100055.-3-29 DO NOTE SCALE FROM DRAWINGS # ISSUE/REVISION DATE .00 FILING SET 10.14.2024 SYMBOLS REGULATORY NOTES ABBREVIATIONS DRAWN BY:J.LACHAPELLE 1. THIS APPLICATION FOR CERTIFICATE OF OCCUPANCY IS FILED A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD CHECKED BY.J.LACHAPELLE LEVEL WITH THE TOWN OF SOUTHOLD BUILDING DEPARTMENT, IN ALT ALTERNATE NOTE:THIS IS AN 11"x 17"SHEET THIRD FLOOR CONFORMANCE WITH THE TOWN CODE CHAPTER 144. APP. APPLIANCE(S) HM HOLLOW METAL DRAWINGS MAYBE PRIMED NOT TO SCALE AO WINDOW EL. +311-3" HT HEIGHT ELEVATION ABOVE 0'-0" 2. THE CONTROLLING CODE IS THE 2020 BUILDING CODE OF NEW B.O. BY OTHER HW HOT WATER LaChapelle Architecture PLLC O DOOR YORK STATE AND THE 2020 ENERGY CONSERVATION CODE OF P.O.Box 1251 NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH. MECHANICAL Mattituck,NY 11952 1 ELEVATION NUMBER CLG CEILING MTL METAL (646)251-5058 jake@lachapellearchitecture.com 1O PARTITION TYPE A6 SHEET NUMBER 3. REFERENCE HEREIN TO 'BC' SHOULD BE CONSTRUED TO MEAN CMU CONCRETE MASONRY UNIT THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CONIC CONCRETE PTD PAINTED CONT. CONTINUOUS 4. THIS SINGLE-FAMILY HOME OCCUPANCY CLASSIFICATION IS CONT'D CONTINUED RCP REFLECTED CEILING PLAN RED AR A3 1 DETAIL NUMBER RESIDENTIAL GROUP R-3 UNDER BC CHAPTER 3. .�� y A4 SHEET NUMBER D.H. DOUBLE HUNG O.C. ON CENTER ��5 \�ACHAp 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE V(B) DIM. DIMENSION (U 0 n� (UNPROTECTED WOOD FRAME) UNDER BC TABLES 601 AND 602. DIA. DIAMETER SIM. SIMILAR DISC. DISCONTINUOUS S.S. STAINLESS STEEL 6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED DWG DRAWING STL. STEEL _ J HEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS, CODES, os3s� y AND REGULATIONS. ELEC. ELECTRIC TYP. TYPICAL �� (:Y STAIR DIRECTION LABELS ENG. ENGINEER FOF NEB EQ. EQUAL V.I.F. VERIFY IN FIELD 00 INSPECTIONS EXIST. EXISTING UP DN W/ WITH FL FLOOR WD. WOOD O SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE u¢curm"�au"oa,u�rz�aro,oaonnnns rarunimracwmucwoeua a wn V m u w m n onm room roa m°m rmrz�x SC M +CARBON MONOXIDE DETECTOR rurc ovn�x°°r"rxr"r uc .macmrz�arss rux.ue REQUIREMENTS OF BCNYS 1704&1705. SMOKE AND CO DETECTORS SHALL COMPLY SCOPE O F WORK DRAWING LIST, WITH UL 268,7th ADDITION FOOTING ABBREVIATIONS, FRAMING,TIE-DOWN/STRAPPING MATCH LINE FINAL THE GENERAL INTENT OF THE WORK IS TO 8UI ► _ -MU ME@K`N SYMBOLS,& NOTES CENTER LINE HE=EXtSTING HDUSE. R a CHANGE OF USE OR OCCUPANCY IS ROPOSED. SHEET NO: BREAK LINE Al SHEET 1 OF 5 '1 , GENERAL NOTES GENERAL NOTES DECK NOTES D®HNAL 1. ALL WORK TO BE PERFORMED BY LICENSED TECHNICIANS TO 8. AS REQUIRED BY ECCNYS R503.1.4 NEW LIGHTING SYSTEMS MUST 1. REFER TO THE LATEST VERSION OF THE AMERICAN WOOD RESIDENCE ACCOMPLISH THE WORK AS OUTLINED IN THIS SET OF CONFORM TO SECTION R404.1:ALL NEW FIXTURES WILL CONTAIN COUNCIL'S 'PRESCRIPTIVE RESIDENTIAL WOOD DECK 1225 LONG CREEK DRIVE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK.ALL HIGH-EFFICIENCY LAMPS. SEE SCHEDULE BELOW, CONSTRUCTION GUIDE'. SOUTHOLD,NY 11971 PLUMBING AND ELECTRICAL WORK SHALL BE CERTIFIED BY PERSONS LICENSED IN THEIR TRADES,WHO SHALL ARRANGE 9. CONTRACTOR TO SCHEDULE AND PROVIDE ACCESS REQUIRED 2. ALL FRAMING LUMBER TO BE NO.1 GRADE OR BETTER, FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.ALL FOR ALL INSPECTIONS.WORK MUST REMAIN ACCESSIBLE AND GROUND-CONTACT PRESSURE TREATED.(GLUE-LAMINATED WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A EXPOSED UNTIL INSPECTED AND ACCEPTED IN WRITING BY THE TIMBER BEAMS ARE ALSO FEASIBLE; PLEASE CONSULT WITH SYSTEMATIC MANNER. INSPECTOR. ARCHITECT FOR SIZING.THEY MUST BE TREATED WITH AN OIL-OR 2. IN ADDITION TO THE REQUIREMENTS OF THE APPLICABLE 10. CONTRACTOR MUST COMPLY WITH ALL BUILDING DEPARTMENT WATER-BORNE PRESERVATIVE IN ACCORDANCE WITH AWPA UI.) BUILDING CODES,ALL WORK MUST CONFORM TO FIRE RULES OF OPERATION (SUCH AS HOURS OF ACTIVITY)AND 3. FLASH TOPS OF FRAMING LUMBER (BEAMS,JOISTS,STRINGERS) DEPARTMENT REGULATIONS, UTILITY COMPANY INSURANCE REQUIREMENTS. WITH PEEL-N-STICK BITUMINOUS PRODUCT FOR DURABILITY. REQUIREMENTS,AND BEST TRADE PRACTICES. 11. CONTRACTOR SHALL NEITHER INTERRUPT NOR RELOCATE 4. ALL FASTENERS,ANCHORS,WASHERS,ETC.TO BE HOT-DIPPED 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE BUILDING SERVICES WITHOUT WRITTEN REQUEST TO THE OWNER GALVANIZED OR STAINLESS STEEL, EXCEPT THAT FLASHING TAX MAP NO.1000.55:3.29 FIELD PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY AND RECEIPT OF WRITTEN CONSENT. FASTENERS MAY ALSO BE SILICONE BRONZE OR COPPER TO g ISSUE/REVISION DATE DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS MATCH FLASHING MATERIAL. TO THE ARCHITECT. 12. CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES WITH THE DEPARTMENT OF BUILDINGS, PAY ALL FEES,OBTAIN ALL PERMITS 8. PROVIDE HURRICANE STRAPPING BY SIMPSON OR EQUAL AT .00 FILING SET 10.14.2024 4. CONTRACTOR SHALL TAKE THEIR OWN DIMENSIONS AND FIELD AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY FOUNDATION-TO-FRAME AND FRAME-TO-FRAME CONNECTIONS, VERIFY ALL DATA CONTAINED HEREIN.THE DIMENSIONAL DATA AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED. IN CONFORMANCE WITH ALL CODE REQUIREMENTS. PROVIDE ALL CONTAINED IN THIS DRAWING SET ARE FOR INFORMATION FASTENERS REQUIRED BY MANUFACTURER. ONLY.THE BUILDING IS NOT SQUARE OR PLUMB SO VARIATION 13. CONTRACTOR SHALL COORDINATE WITH OWNER'S SURVEYOR IN EXISTS IN THE DIMENSIONS OF THE EXISTING BUILDING.AS A ADVANCE TO PROVIDE FOUNDATION SURVEY AS SOON AS 9. ALL CONNECTORS (JOIST HANGERS, STRAPPING, ETC.)SHALL BE DRAWN BY:I.LACHAPELLE RESULT DIMENSIONS OF NEW CONSTRUCTION MAY VARY FROM CONCRETE IS PLACED,AND SUBMIT TO SOUTHOLD BUILDING HOT-DIPPED GALVANIZED OR STAINLESS STEEL. CHECKED BY.J.LACHAPELLE THOSE SHOWN.CONTRACTOR SHALL NOTIFY ARCHITECT OF DEPARTMENT OR TRUSTEES, IF REQUIRED. NOTE:THIS IS ANi1"x17"SHEET DISCREPANCIES AS THEY ARISE. 10. BEAM SPLICES MUST OCCUR AT POSTS.STAGGER SPLICES WHEN DRAWINGS MAY BE PRINTED NOT TO SCALE 14. PRIOR TO COMMENCING OPERATIONS ON SITE THE COMPOSED OF TWO 2x1OS. 5. MINOR DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY CONTRACTOR SHALL PROVIDE BOTH OWNER AND ARCHITECT LaChapelle Architecture PLLC FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK 'ACORD' INSURANCE FORM LISTING THE FOLLOWING PARTIES AS 11. AZAK DECKING BY TIMBER TECH TO BE FACE FASTENED OR 251 1 Box x SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE ADDITIONALLY INSURED: TOENAIL FASTENED USING THE 'CAMO' SYSTEM. DECKING COLOR Ma P.O. , 1 11952 DRAWINGS. KIM &BRETT DOHNAL TO BE SELECTED BY OWNER. LACHAPELLE ARCHITECTURE PLLC (646)251-5058 jake@lachapellearchitecture.com 6. CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES THE CONTRACTOR MAY NOT BEGIN SITE OPERATIONS OF ANY WITH REQUIREMENTS OF LOCAL AUTHORITIES AND OWNER. KIND UNTIL THE ABOVE IS PROVIDED. 7. THE CONTRACTOR SHALL ENSURE THE STRUCTURAL STABILITY \S-�EREpq� OF ALL AREAS OF THE WORK THROUGHOUT OPERATIONS.THE �G �E Lacy C! CONTRACTOR SHALL DO SO BY WHATEVER MEANS HE DEEMS ARE NECESSARY,INCLUDING BUT NOT LIMITED TO RETAINING A n LICENSED ENGINEER AT THE CONTRACTOR'S EXPENSE TO -� OVERSEE AND ADVISE ON THE WORK. r OF IEV00 LIGHT FIXTURE SCHEDULE ID FIXTURE TYPE MAKEIMODEL TEMPERATURE WET LOCATION FULL CUTOFF NOTES NOTES& ENERGY AA EXTERIOR SCONCE TBD MAX.3,000K YES YES LANTERN SCONCE SIMILAR TO EXISTING ON HOUSE CODE COMPLIANCE BB EXTERIOR RECESSED WAC R4FS-WT 2,700K YES YES WHITE FINISH,SET FLUSH INTO CEILING;AIM AT WALL CC STEP LIGHTS WAC WL-LED101-27-WT 2,700K YES YES WHITE FINISH,SET FLUSH INTO STEP RISER SHEET N0: DD POST LIGHTS MAXIM LIGHTING 52120-SV 2,700K YES YES SILVER FINISH, INSTALL DRIVERS IN WEATHERPROOF BOXES UNDER STAIR A2 SHEET 2 OF 5 LANDWARD LIMIT OF TIDAL WETLAND �' 22, DOHNAL AS FLAGGED BY COLE ENVIRONMENTAL /� T RESIDENCE SERVICES ON 12/06/2023 /,0 so TOP OF BANK,PER SURVEY BY HAROLD /.� .� - ^6! . 1225 LONG CREEK DRIVE TRANCHON JR. P.C.DATED 413/2023 aN SOUTHOLD,NY 11971 TAX MAP NO. 1000-55:3-29 ZONE: R-40 RESIDENTIAL LOW-DENSITY(ONE-ACRE) CODE EXISTING PROPOSED COMMENTS LOT INFORMATION: LOT AREA SF 40,000 24,199* NO CHANGE EXIST.NON-CONFORMING LONG CREEK •' r REAR YARD UPLAND AREA(SF) 40,000 22,231 * NO CHANGE EXIST.NON-CONFORMING / y r 1 NON-DISTURBANCE BUFFER LOT WIDTH(FT) 150 159.8 NO CHANGE COMPLIES NON-TURF BUFFER LOT DEPTH(FT) 175 223.0 NO CHANGE COMPLIES LOT COVERAGE(SF) 4,446 2,004 NO CHANGE COMPLIES I 1 o PROPOSED FENCE LOT COVERAGE(%) 20.0 9.0 NO CHANGE COMPLIES PROPOSED ( r r 1 '10' DECK(673 SF), I PROPOSED OUTDOOR SETBACKS: SEE SK-18 i/ r i SHOWER(32 SF) TAX MAP NO.1000-55.3.29 FRONT YARD(FT) 40 75 NO CHANGE COMPLIES # ISSUE/REVISION DATE SIDE YARD(FT) 15 12.7 NO CHANGE EXIST. NON-CONFORMING r r 12��\���, BOTH SIDE YARDS FT 35 32.7 NO CHANGE EXIST. NON-CONFORMING r r / \� \ SIDE YARD .00 FILING SET 10.14.2024 REAR YARD(FT). 50 92.2 NO CHANGE COMPLIES I BUILDING DIMENSIONS: l ti 1 HEIGHT(FT) 35 <35 NO CHANGE COMPLIES ,\ I 2 STORY STORIES(# 2 2 NO CHANGE COMPLIES SIDE YARD �h I SINGLE- 15,-�� MILY DRAWN BY.7 LACHAPELLE r ABOVE DATA PROVIDED FOR THIS APPLICATION ONLY;SEE ALSO DECK APPLICATION i H � LOT N0. 14 CHECKED BY:1.LACHAPELLE *SEE 12/21/2023 SURVEY BY HAROLD F.TRANCHON JR.P.C. FOR CALCULATION r NOTE:THIS IS AN II"x17"SHEET DRAWINGS MAY BE PRINTED NOT TO SCALE MEAN LOW WATER LINE ' a 1 LaChapelle Architecture PLLC ? P.O.Box 1251 OUTLINE OF Mattituck,NY 11952 r I EXISTING (646)251-5058 jake@lachapellearchitecture.com PATIO MEAN HIGH WATER LINE ,r fir, r ASPHALT DRIVE \ LOT LINE ED qRC Ll \ I ' 12' r r 0d , . i 9 j03030O �OF NE`N LOT NO. 12 r o •� r Tx°oxnwxs°u,wnxuw[xrora[mrc[x"xmuwsrn[vxo,[mr"[uexn,nu co / KCH"[C Mv[R a4LLi[aMx[,o40[[�IiTIwUW[[xala dCV}aV[FCxeP4[L ° ' (� axMMpx Tolwamw[C[avo[MxmNrt"s."x f00.C""M1[iNx"f 11Cf Pea[n aY DATA T" 3� � � ¢avm,uurixeaxm[x eora[mov u[xru[¢[,xcxn[ervian[c VED /2023 TRUE HAROLD F.TRANCOHON JR1P.C.LAND BY rr '� 6� �� / i NORTH SITE PLAN SURVEYOR;DRAFTING OF THIS SITE PLAN BY i �6g°3 COG LACHAPELLE ARCHITECTURE PLLC I i PROJECT NORTH SHEET NO: OSITE PLAN ZONING DIAGRAM i (13.42°) SCALE: 1/32" = T-0" A3 SHEET 3 OF 5 1N DOHNAL POST i POST RESIDENCE DECKING (2)SIMPSON 1225 LONG CREEK DRIVE / SIMPSON ♦ / DTT2 ♦ SOUTHOLD,NY 11971 / DTT2 DECKING (ONE EACH ` SIDE) , SIMPSON STANDARD / RAILING ATTACHMENT N ® ® \ ! N so ® ® ® 1 DETAILS 1 —® ® ® ® I 1 ® ® ® ® ® ® ® ® 1 ADJUST FOR PROJECT CONDITIONS I I _ I I L 1 RAILING NOTE: ; `% PROVIDE 36"RAILING AT ALL LOCATIONS WHERE 16"MIN. TAX MAP NO.1000.55,-3 29 DROP IS OVER 30" JOIST RIM JOIST a ISSUE/REVISION DATE ♦ %"DIA.BOLTS OR / BLOCKING / ♦ THREADED ROD w/ / JOIST .00 FILING SET 10.14.2024 DETAIL �.` NUPTSANDWASHERS,� / DETAIL �.` �./ TY / DETAIL'A' N I N I AZEK FASCIA DRAWN BY:J.LACHAPELLE / SIMPSON DTT2 ♦ REMOVE AND REPLACE CHECKED BY:J.LACHAPELLE / TO JOIST LAYOL RIM JOIST ♦ EXISTING HOUSE SIDING IN i NOTE:THIS IS AN II"x17"SHEET ORDER TO ACCEPT NEW 8" DRAWINGS MAY BE PRINTED NOT TO SCALE / STAINLESS STEEL FLASHING SIMPSON LUS28 JOIST LaChapelle Architecture PLLC BAND JOIST HANGER,TYP. = P.O.Box 1251 / Mattituck,NY 11952 ;\ \ PROVIDE POLYETHYLENE _ (646)251-5058 jake@lachapellearchitecture.com (OR OTHER / — \ WEATHER-RESISTANT) _- DECK JOISTS LEDGER SPACERS FOR i w / BLOCKING DRAINAGE i Q RED A&C D -MOUNT JOISTS TO GIRDERS DTT2 TO FLUSH I BLOCKING I DUE TO LOW PROFILE OF DECK LAYOUT ' PROVIDE GALVANIZED STRAPPING i yt FROM EACH JOIST TO GIRDER SIMPSON LPC6Z AT POST TO \ ® / GIRDER CONNECTION �TF �0 \ 2x4 BRACES FROM FRAMING TO ° • b: .;.' OF N E`N ® POSTS; PROVIDE INFILL BELOW b / DECK PER OWNER / SIMPSON ABU66SS 6X6 ADJUSTABLE STAINLESS NRDR. RDR,N,R.R„EN°,E[�[RNDRxR�'[PRD F�°TAD RPI�[ •` • �,R"[ttY tttc pF°nn°t[SSDIMMITX[R!N[PN°I[Ct iDRISMICNp RPRFvpR!°R MRxRR Ptt[RA W x•OR DLM1"°NE MPT E[eME[[#[PI eY LPcxRPELL! R,cWf[<NP�*LLCTnPRW RE mYPOT Ol EE[D eYDTN[A PNRI[ENPElNNPRd[ttD, / STEEL POST BASE W/STANDOFF FASTENED TO I •I °01M[NPRiRIt9 Nnx°Ef[N[wPRTDlcOxE[N[DIIKNVL4[RRCMR[ttER[v".c. m mvrm°nr xcea umaPuu RRcw"ttu R!Puc FOOTING PER MFR DIRECTION •° is a Co / 18 DIA.FLARED FOOTING BOTTOM, ° '. ; r i. .i DECK DETAILS ♦ / OR 16"x16"SQUARE,REINFORCED ♦ �' CONCRETE 250OPSF MIN. ;o SHEET N0: PLAN VIEW TYPICAL SECTION a A5 SHEET 5 OF 5 DOHNAL RESIDENCE 1225 LONG CREEK DRIVE L 1225 LONG CREEK DRIVE SOUTHOLD,NY 11971 SOUTHOLD, NY DRAWING LIST GARAGE ALTERATION A1.00 DRAWING LIST, ABBREVIATIONS, SYMBOLS, &NOTES A2.00 NOTES A3.00 SCHEDULES &ENERGY CODE COMPLIANCE SCTM#-1000-55.-3-29 A4.00 GENERAL PLAN A5.00 GARAGE PLAN A6.00 DETAILS TAX MAP NO.1000.55:3-29 # ISSUE/REVISION DATE NOTE: DO NOT SCALE FROM DRAWINGS 00 FILING SET 09.10.2024 SYMBOLS REGULATORY NOTES ABBREVIATIONS DRAWN BY.J.LACHAPE LLE 1. THIS APPLICATION FOR CERTIFICATE OF OCCUPANCY IS FILED A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD CHECKED BY.J.LACHAPELLE LEVEL WITH THE TOWN OF SOUTHOLD BUILDING DEPARTMENT, IN ALT ALTERNATE NOTE:THIS IS AN 11"x 17"SHEET THIRD FLOOR CONFORMANCE WITH THE TOWN CODE CHAPTER 144. APP. APPLIANCE(S) HM HOLLOW METAL DRAWINGS MAY BE PRINTED NOT TO SCALE AO WINDOW EL. +31'-3" HT HEIGHT ELEVATION ABOVE 0'-0" 2. THE CONTROLLING CODE IS THE 2020 BUILDING CODE OF NEW B.O. BY OTHER HW HOT WATER LaChapelle Architecture PLLC 2O DOOR YORK STATE AND THE 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, IN COMBINATION WITH THE TOWN CODE. C/C CENTER TO CENTER MECH, MECHANICAL P.O.Box 1251 Mattituck,NY 11952 SHEET NUMBER 1O PARTITION TYPE 1 ELEVATION NUMBER 3. REFERENCE HEREIN TO 'BC' SHOULD BE CONSTRUED TO MEAN CMU CONCRETE MASONRY UNIT CLG CEILING MTL METAL (646)251-5058 jake@lachapellearchitecture.com A6 THE APPLICABLE BUILDING CODES OF NEW YORK STATE. CONC CONCRETE PTD PAINTED CONT. CONTINUOUS 4. THIS SINGLE-FAMILY HOME OCCUPANCY CLASSIFICATION IS CONT'D CONTINUED RCP REFLECTED CEILING PLAN A3 1 DETAIL NUMBER RESIDENTIAL GROUP R-3 UNDER BC CHAPTER 3. �FtED qR A4 SHEET NUMBER D.H. DOUBLE HUNG O.C. ON CENTER \5� �ACHgoCy�j. 5. THIS STRUCTURE IS CLASSIFIED AS CONSTRUCTION TYPE V(B) DIM. DIMENSION (UNPROTECTED WOOD FRAME) UNDER BC TABLES 601 AND 602. DIA. DIAMETER SIM. SIMILAR DISC. DISCONTINUOUS S.S. STAINLESS STEEL 6. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED DWG DRAWING STL. STEEL _j HEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS, CODES, AND REGULATIONS. ELEC. ELECTRIC TYP. TYPICAL 9> ° O� STAIR DIRECTION LABELS ENG. ENGINEER �OF NE`l`t� 00 EQ. EQUAL V.I.F. VERIFY IN FIELD UP DN INSPECTIONS EXIST. EXISTING W/ WITH HER RESISTIVE BARRIER SC R SMOKE+CARBON MONOXIDE DETECTOR SPECIAL INSPECTIONS MUST BE PROVIDED IN CONFORMANCE WITH THE FL FLOOR WRB WEATHER WD. WOOD SMOKE AND CO DETECTORS SHALL COMPLY REQUIREMENTS OF BCNYS 1704&1705. WITH UL 268,7th ADDITION FRAMING, TIE-DOWN/STRAPPING AND PLUMBING SCOPE O F WORK DRAWING LIST, PERIMETER INSULATION ABBREVIATIONS, — MATCH LINE ROUGH ELECTRIC SYMBOLS, & NOTES CENTER LINE INSULATION AND CAULKING THE GEN_ERA IN_ENT OF HE WORK IS T BU1LDtA M_UD R 0 r r . . S L THE, #StN___ RAGiNO CHANGE OF USE OR ENERGY CODE COMPLIANCE �•z' a�� - ^�- w�. BREAK LINE FINAL OCCUPANCY7IS�PROP'GSED..- SHEET NO: Al SHEET 1 OF 6 L GENERAL NOTES GENERAL NOTES GENERAL NOTES DOHNAL 1. ALL WORK TO BE PERFORMED BY LICENSED TECHNICIANS TO 7. THE STRUCTURAL MODIFICATIONS TO THE HOUSE INCLUDED 13. CONTRACTOR SHALL NEITHER INTERRUPT NOR RELOCATE RESIDENCE ACCOMPLISH THE WORK AS OUTLINED IN THIS SET OF HEREIN MAKE THIS A LEVEL 2 ALTERATION UNDER EXISTING BUILDING SERVICES WITHOUT WRITTEN REQUEST TO THE OWNER 1225 LONG CREEK DRIVE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK. ALL BUILDING CODE (EBC)CHAPTER 6. REQUIREMENTS OF BC AND RECEIPT OF WRITTEN CONSENT. SOUTHOLD,NY 11971 PLUMBING AND ELECTRICAL WORK SHALL BE CERTIFIED BY CHAPTER 7 AND 8 APPLY AS A RESULT.CONTRACTOR SHALL PERSONS LICENSED IN THEIR TRADES,WHO SHALL ARRANGE CAREFULLY OBSERVE THE REQUIREMENTS OF SECTION 806. 14. CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES WITH THE FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.ALL DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A 8. STRUCTURAL OBSERVATION IS NOT REQUIRED UNDER BC 1704.6 AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY SYSTEMATIC MANNER. BECAUSE THE BUILDING IS NOT IN THE INDICATED RISK AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED. CATEGORIES AND NOT A HIGH-RISE BUILDING. 2. IN ADDITION TO THE REQUIREMENTS OF THE APPLICABLE 15. CONTRACTOR SHALL COORDINATE WITH OWNER'S SURVEYOR IN BUILDING CODES,ALL WORK MUST CONFORM TO FIRE 9. PROPOSED GWB FINISHES MUST COMPLY WITH BC CHAPTER 8. ADVANCE TO PROVIDE FOUNDATION SURVEY AS SOON AS DEPARTMENT REGULATIONS, UTILITY COMPANY TAPED, PRIMED,AND PAINTED GWB IS ALLOWED UNDER BC 803 CONCRETE IS PLACED,AND SUBMIT TO SOUTHOLD BUILDING REQUIREMENTS,AND BEST TRADE PRACTICES. AND QUALIFIES AS A CLASS-A MATERIAL WITH FLAME SPREAD DEPARTMENT. INDEX LESS THAN 25 AND SMOKE-DEVELOPED INDEX BELOW 450. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE THIS EXCEEDS THE REQUIREMENTS OF BC TABLE 803.13 FOR THIS 16. PRIOR TO COMMENCING OPERATIONS ON SITE THE TAX MAP NO.1000.55:3-29 FIELD PRIOR TO COMMENCING WORK,AND SHALL REPORT ANY OCCUPANCY R-3. CONTRACTOR SHALL PROVIDE BOTH OWNER AND ARCHITECT DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS ACORD' INSURANCE FORM LISTING THE FOLLOWING PARTIES AS k ISSUE/REVISION DATE TO THE ARCHITECT. 10. INTERCONNECTED SMOKE DETECTOR ALARMS SHALL BE ADDITIONALLY INSURED: PROVIDED IN CONFORMANCE WITH 'FIRE CODE'1103.8 AND KIM AND BRETT DOHNAL .00 FILING SET 09.10.2024 4. CONTRACTOR SHALL TAKE THEIR OWN DIMENSIONS AND FIELD CARBON MONOXIDE DETECTION EQUIPMENT MUST BE PROVIDED LACHAPELLE ARCHITECTURE PLLC VERIFY ALL DATA CONTAINED HEREIN.THE DIMENSIONAL DATA IN CONFORMANCE WITH 'EXISTING BUILDING CODE' SECTION 804, THE CONTRACTOR MAY NOT BEGIN SITE OPERATIONS OF ANY CONTAINED IN THIS DRAWING SET ARE FOR INFORMATION IF NOT ALREADY PRESENT IN THE BUILDING. KIND UNTIL THE ABOVE IS PROVIDED. ONLY.THE BUILDING IS NOT SQUARE OR PLUMB SO VARIATION EXISTS IN THE DIMENSIONS OF THE EXISTING BUILDING.AS A 11. CONTRACTOR TO SCHEDULE AND PROVIDE ACCESS REQUIRED 17. THE CONTRACTOR SHALL ENSURE THE STRUCTURAL STABILITY OF DRAWN BY.J.LACHAPELLE RESULT DIMENSIONS OF NEW CONSTRUCTION MAY VARY FROM FOR ALL INSPECTIONS.WORK MUST REMAIN ACCESSIBLE AND ALL AREAS OF THE WORK THROUGHOUT OPERATIONS. THE CHECKED BY:J.LACHAPELLE THOSE SHOWN. CONTRACTOR SHALL NOTIFY ARCHITECT OF EXPOSED UNTIL INSPECTED AND ACCEPTED IN WRITING BY THE CONTRACTOR SHALL DO SO BY WHATEVER MEANS HE DEEMS NOTE:THIS IS AN 11"x17"SHEET DISCREPANCIES AS THEY ARISE. INSPECTOR. ARE NECESSARY, INCLUDING BUT NOT LIMITED TO RETAINING A DRAWINGS MAY BE PRINTED NOT TO SCALE LICENSED ENGINEER AT THE CONTRACTOR'S EXPENSE TO 5. MINOR DETAILS NOT SHOWN OR SPECIFIED, BUT NECESSARY 12. CONTRACTOR MUST COMPLY WITH ALL BUILDING DEPARTMENT OVERSEE AND ADVISE ON THE WORK. LaChapelle Architecture PLLC FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK RULES OF OPERATION (SUCH AS HOURS OF ACTIVITY)AND SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE INSURANCE REQUIREMENTS. P.O.Box 1251 DRAWINGS. Mattituck,NY 11952 6. CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES (646)251-5058 jake@lachapellearchitecture.com WITH REQUIREMENTS OF LOCAL AUTHORITIES AND OWNER. ED ARC �5 LACHgp yam). L 033930 QQ" A �CF NE`T'� Tms wwnw o w umwmLirt a ssmxe wo gLnugs ra vmvEim a ucgeveEL wGNECN qE gLLC F V.MIXESI OLWIH]XW iNL qMI ECf EOq W HICX R 6 i1QPOpEO 6 EttavrtaxoowwEaurrannoas,ogq¢Enmu wYecouoeEurvrerucwvEi]L Fq�OfECNgf L{lCTOS Og4W0VO LYY XOTBFUSFDBY OIMggw116fOq011¢Ilgp0tC15, Eogwomogrorw wmucrmamEgvaqvs,ogrogco�mogamsvxoiEttor wms,wmourrarmrm E+Egcae�xraL IAEYMYEwuLIFt ItEVLLG ®OOT'IOOM30]IAOgAPELLEpgOqILONqE gLLC NOTES SHEET NO: JA 2 SHEET 2 OF 6 WINDOW & DOOR SCHEDULE, ENERGY CODE COMPLIANCE DOHNAL U-FACTOR/R-VALUE RESIDENCE ID ASSEMBLY MAKE/MODEL DIMENSIONS HARDWARE NOTES QTY ECCNYS PROPOSED 1225 LONG CREEK DRIVE ENTRY DOOR REEB OR SIM, 36"x 84" ENTRY&DEADBOLT RH INSWING;SOLID WOOD OR COMPOSITE PER OWNER 1 0.55 TBD SOUTHOLD,NY 11971 10 NOM.4"NEW PARTITION 3.5"CLOSED-CELL SPRAY FOAM INSULATION - 20 24(PASS) ROOF 12"MINERAL WOOL(COMFORTBATT BY ROCKWOOL) - 49 49(PASS) FLOOR 5.5"MINERAL WOOL(COMFORTBATT BY ROCKWOOL) - 19 23(PASS) TAX MAP NO.100D-55:3-29 ENERGY NOTES # ISSUE/REVISION 09.10.2024 DATE 1. THE WORK PROPOSED HERE MUST CONFORM TO ECCNYS .00 FILING SET R502 FOR ADDITIONS WHERE APPLICABLE,AND TO ECCNYS 3. IN ACCORDANCE WITH R503.1.1.2 EXISTING CEILING,WALL, R503 REQUIREMENTS FOR ALTERATIONS WHERE APPLICABLE. OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION OF AN ALTERATION NEED NOT MEET THE REQUIREMENTS OF 2. AS REQUIRED BY ECCNYS TABLE R402.1.2 THE NEW THE ECCNYS, PROVIDED THAT THE EXPOSED CAVITIES ARE PLUMBING DRAWN BY:J.LACHAPELLE PERIMETER WALL ASSEMBLY MUST ACHIEVE R-20.THE NEW FILLED w/INSULATION. RISER DIAGRAM CHECKED BY:J.LACHAPELLE ROOF ASSEMBLY MUST ACHIEVE R-49.THE NEW FLOOR MUST ACHIVE R-19.THE PROPOSED ASSEMBLIES EXCEED 4. AS REQUIRED BY ECCNYS R503.1.4 NEW LIGHTING SYSTEMS I NOTE:THIS 15AN11"x17"SHEET DRAWINGS MAYBE PRINTED NOT TO SCALE SEE COMPLIANCE CHART ABOVE. MUST CONFORM TO SECTION R404.1:ALL NEW FIXTURES WILL CONTAIN HIGH-EFFICIENCY LAMPS. SEE COMPLIANCE CHART BELOW. I LaChapelle Architecture PLLC _ P.O.Box 1251 ----- Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture.com LAV , SO Al2C,y�J, WASHER �� �pCHAp CONNECT NEW SY BRANCH TO __lJTO SEPTIC EXISTING rF O F NEB LIGHT FIXTURE SCHEDULE ~nXnµEN� E�rtRnP NeP��Ya�X�� urcwrterv`a v"eRrmaouseummxmnevRUEcrioawocX rtnPaEPuron E#W 1ED,xu cRavcix arzRnmra,OR Duman renv ee rnoe exienr er uc RnvEua ARMRFCNRL PLLC,Mn DR9 W W 0 PAY NaT BE USFD BY OM[R PM116 i0R OINFR pgORO@, i0RP0011roN}p�PRaER8Y01XERPMllE9,ORiaiCOlVLnIOXallu9 PpN[ROY OtXFA PARIIE;N'If110UTMEVMREN WNSENiOY ULCMJUIEClUU(PLLC ®COVRtlOM}eW(FGHpP[LLEARCHIfECNREPLLO FIXTURE TYPE MAKE/MODEL TEMPERATURE WET LOCATION FULL CUTOFF NOTES SCHEDULES & ENERGY AA INTERIOR RECESSED WAC RR3ARAT-S827-WT 2,700K NO N/A WHITE FINISH,TRIM TO MATCH EXISTING KITCHEN LIGHTS CODE COMPLIANCE BB UNDER CABINET WAC PR02 SYSTEM 2,700K NO N/A 330 LM/FT;MOUNT DRIVER(IF APPLICABLE)ABOVE CABINET SHEET NO: JA 3 SHEET 3 OF 6 / r r DOHNAL ' RESIDENCE 0 � ' o 1225 LONG CREEK DRIVE ,N SOUTHOLD,NY 11971 TAX MAP NO. 1000-55.-3-29 ZONE: R-40 RESIDENTIAL LOW-DENSITY(ONE-ACRE) CODE EXISTING PROPOSED COMMENTS $ LOT INFORMATION: LOT AREA SF 40,000 24,199' NO CHANGE EXIST. NON-CONFORMING LONG CREEK !% %./ /. UPLAND AREA(SF) 40,000 22,231 * NO CHANGE EXIST. NON-CONFORMING i ,r LOT WIDTH(FT) 150 159.8 NO CHANGE COMPLIES LOT DEPTH(FT) 175 223.0 NO CHANGE COMPLIES i `!�i / — ` L LOT COVERAGE(SF) 4,446 2,004 NO CHANGE COMPLIES r i] li i i ` o i j: 1. REAR YARD LOT COVERAGE % 20.0 9.0 NO CHANGE COMPLIES II.! ! i � �10' SETBACKS: j J! ill��i �•.� 1\`� TAX MAP NO.1000.55.329 FRONT YARD(FT) 40 75 NO CHANGE COMPLIES SIDE YARD(FT) 15 12.7 NO CHANGE EXIST. NON-CONFORMING j !�� ! 12��'�� n ISSUE/REVISION DATE BOTH SIDE YARDS FT 35 32.7 NO CHANGE EXIST. NON-CONFORMING REAR YARD FT 50 92.2 NO CHANGE COMPLIES i! ! a ; - - � \� �., SIDE YARD .00 FILING SET 09.10.2024 BUILDING DIMENSIONS: 1=! i HEIGHT FT 35 <35 NO CHANGE COMPLIES 2 STORY 1q,4� ,� � I � _ STORIES # 2 2 NO CHANGE COMPLIES a . ! SINGLE- „ SIDE oh -FAMILY 15�-0 r DRAWN BY:J.LACHAPELLE LOT NO. 14 CHECKED BY:J.LACHAPELLE SEE 12/21/2023 SURVEY BY HAROLD F.TRANCHON JR. P.C. FOR CALCULATION i NOTE:THIS IS AN ii"x 17"SHEET DRAWINGS MAY BE PRINTED NOTTO SCALE GARAGE MAXIMUM GROSS SQUARE FOOTAGE CALCULATION FOR LOTS UP TO 30,000 SF: 3,350 SF ALLOWED+101/6 OF(22,231 SF-20,000 SF)=3,573 SF ALLOWED La Chapelle Architecture PLLC P.O.Box 1251 i ! Mattituck,NY 11952 CODE PROPOSED COMMENTS GROSS SQUARE FOOTAGE: 'I. (646)251-5058 jake@lachapellearchitecture.com i . ! � EXISTING 1st FLOOR(GSF) — 1,798 I I i ;b'� EXISTING 2nd FLOOR(GSF) — 698 /�`� ASPHALT i TOTAL(GSF) 3,573 2,496 COMPLIES§280-207 .� �! �:I �.\ DRIVE LOT LINE FLED q o , /* i. LOT NO. 12 .•�' N �. �► 0339313 ii i' A D FOFNEvy�IO � a�wn�rtc�iu"u6pru amwps�zs°avmemwiier�imw�irnriuou �' x / �cru'rse uc na'au�r�"ur xore ue�seu ero�an�am¢�sirn�an,m�Peacrtm, / a+�emonro}xnr�ctrevmxmrumenoxrwmMxerrox orran maeum O I�\O / / P��®CO%RpM40W31�4CNOPELLEMtlIRFLTYNIPYGNIIECNMRlt. DATA DERIVED FROM 12/21/2023 SURVEY BY z TRUE HAROLD F.TRANCHON JR. P.C. LAND 0 6,�p'� ������ NORTH GENERAL PLAN SURVEYOR; DRAFTING OF THIS SITE PLAN BY I 3 G LACHAPELLE ARCHITECTURE PLLC I vow, T PROJECT NORTH SHEET NO: T /� 4 SITE PLAN / ZONING DIAGRAM /� �' i (13.42°) SCALE: 1/32" = 1'-0" � • /'"'� SHEET 4 OF 6 DEMOLISH DOORS AND PANTRY DOH NAL WALLS AS INDICATED;PATCH RESIDENCE WALLS AS NEEDED KITCHEN 1225 LONG CREEK DRIVE PROVIDE NEW FLOOR-TO-CEILING SOUTHOLD,NY 11971 SHELVING IN PANTRY CLOSET FORMER REFRAME WALL FOR POCKET LAUNDRY DOOR TRACK PROPOSED DINING PANTRY NO WORK IN POWDER ROOM RELOCATE EXISTING CENTRAL NEW 2'GWB CEILING; PROVIDE VACUUM UNIT TO BASEMENT IN HURRICANE TIES AT EACH AFFECTED AREA BELOW;VACUUM UNIT BY ROOF RAFTER AND TOP PLATE M.D.MANUFACTURING INC., 120V, CONNECTION 14.1A-REROUTE PVC VACUUM '3 Y POWDER PIPE, PROVIDE NEW CIRCUIT AND RECEPTACLE AS NECESSARY �;� ,a AREA OF WORK TAX MAP NO.IOOD-55:3-29 ' — ' — ' — ' — ' — ' — — ' , — '' \1 — ' REMOVE EXIST.SHELVING; PROVIDE # ISSUE/REVISION DATE _ NEW UPPER AND LOWER CABINETS AND<20"WIDE UTILITY SINK .00 UPDATED FILING SET 10.22.2024 _ (2)NEW DUPLEX GFI ` PROPOSED I v RECEPTACLES ABOVE COUNTER 1O MUD ROOM fi kD NEW RECESSED WATER SUPPLY L__ I - AND DRAIN BOX FOR WASHER DRAWN BY:J.LACHAPELLE NEW DRYER VENT TO EXTERIOR CHECKED BY:J.LACHAPELLE NEW GWB AT MUD ROOM-SIDE 11'-5" w/GRAVITY DAMPER FACE OF FLUE TO PROVIDE FLUSH NOTE:THIS IS AN ir"x 17"SHEET WALL SURFACE AT INTERFACE w/ NEW GFI RECEPTACLE FOR DRAWINGS MAY BE PRINTED NOT TO SCALE NEW WALL;MAINTAIN INTEGRITY WASHER;AMPERAGE TBD OF FLUE THROUGHOUT ' — — — NEW DRYER RECEPTACLE; LaChapelle Architecture PLLC AMPERAGE TBD P.O.Box 1251 2x4 WOOD FRAMING;2'GWB INTERIOR; Mattituck,NY 11952 DN 1 USE HENRY AIR-BLOC 31-MR OR (646)251-5058 jake@lachapellearchitecture.com OTHER AOR APPROVED EXIST. A6 LIQUID APPLIED VAPOR BARRIER LP GAS OVER!'PLYWOOD AT EXTERIOR; PROVIDE 3.5"CLOSED CELL SPRAY GARAGE2-CAR � - FOAM INSULATION FOR R24.5 �\5�ER�D q�cy��, ICN r; PLEASE NOTE LEAD-TIME FOR HENRY AIR �m n 180"AUTO BARRIER PRODUCT AND ORDER EARLY 9 .A FILL CELLS BETWEEN STUDS IN EXPOSED EXTERIOR WALL AND yp RAFTERS IN EXPOSED CEILING OP NE ® WITH MINERAL WOOL BATT INSULATION TO COMPLY WITH ENERGY CODE 1NI5 DRAVlIXD n N!NLSIDIIMEMT Cf e[itML Ax D NFNA4v4 M PxOPFXIT K IICINPFttF axcwaaDa iucamumunawi¢mcx evaymraxwxn:urtnPwnu+mn mNien.xoources.xmumm�.Dxoeuttars DurmwceeaavrerxxnvPue !,@ixEDNPE PLLC1MnDMYIPM NAY NDTBEDSm BY DTNNPNlDBPoPDIHFA Pp6FC1S, eoxaoon"xrorwewmxereronffavaxw.a+m+mewnnxavrimmveerm mMPIHDe5,KRDIDUfIK YWR[x CDx5ENi0[NONPWLTFCMIECNPEPLLG ®cavrm�rsme unuvauaxamernve vus EXISTING TRUE PARTITION NORTH (13.42°) GARAGE PLAN ® 0 SHEET NO: NEW PARTITION PROJECT OCONSTRUCTION PLAN - NEW LAUNDRY ROOM OR ADJUST NORTH �� SCALE: 1/4" = T-0" FRAMING SHEET 5 OF 6 DOHNAL EXISTING CEILING JOISTS;STACK RESIDENCE --Val I IN-,, , I I I I I MINERAL WOOL INSULATION(R49) 1225 LONG CREEK DRIVE / SOUTHOLD,NY 11971 / CEILING HEIGHT EXCEEDS R305.1 MINIMUMS \ DRYER KITCHEN \ GARAGE PORCELAIN TILE AT WALL PULL-OUT SHELF FOR LAUNDRY TIP OUT SPONGE TRAY TAX MAP NO.100a55:8-29 BASKET ON HEAVY-DUTY DRAWER DOOR w/PULL-OUT FOR DETERGENT, ETC. RUNNERS:::�� q ISSUE/REVISION DATE 24"x12"PORCELAIN TILE PER OWNER; -- J PROVIDE MUDSET OR 0.40"HARDIBACKER 7„ 2x4 WALL FRAMING @ 16"O.C.; FILL .00 UPDATED FILING SET 10.22.2024 ON 4'PLYWOOD SUBFLOOR WASHER w/CLOSED CELL SPRAY FOAM 24" INSULATION(1124) l 2x8 FLOOR JOISTS @ 16"O.C.; �_ i MINERAL WOOL INSULATION(R23) — DRAWN BY:J.LACHAPELLE 4" P.T.2x6 PLATE; USE CHECKED BY:J.LACHAPELLE OINTERIOR ELEVATION POWDER ACTUATED NAILER OR 1 �iw PRE-DRILLED TAPCON SCREWS NOTE:THIS IS AN 11„x 17"SHEET SCALE: 112" = T-O" "' TO FASTEN TO EXISTING SLAB DRAWINGS MAY BE PRINTED NOTTO SCALE LaChapelle Architecture PLLC REFRAME WALL FOR POCKET DOOR 1'-7Z' -�`- P.O.Box 1251 TRACK, NEW TRIM AND GWB AT 4-0r FILL CELLS BETWEEN STUDS IN EXPOSED Mattituck,NY 11952 PERIMETER AS NEEDED CLEAR EXTERIOR WALL AND RAFTERS IN EXPOSED (646)251-5058 jake@lachapellearchitecture.com CEILING WITH MINERAL WOOL BATT INSULATION TO COMPLY WITH ENERGY CODE UNDER CABINET LIGHT \SjeREO, /? G E►-ACiy C'y 1 WB ;; y \ Ak//� `1 ���\ j AA 1 NEW RECESSED WATER SUPPLY AND DRAIN BOX �` Q` NEW DUPLEX GFI RECEPTACLE \ � � A6 � FOR WASHER OF NEW�� ' NEW CUSTOM SHELVING FOR BOOTS,ETC. \ �� FRAME LANDING SIMILAR TO MUD ROOM. l _ 2x4 WOOD FRAMING;2'GWB INTERIOR; 3'-7" i� — 3'-7" // eulm xo„cw�wc4un0„S.MMLLipraiSrrMo„ibxVf�� USE HENRY AIR-BLOC 31-MR OR OTHER O - „cwrzenmc"a wo„nxma uv„o erauo„ommvaarms o„oraavaarem. ray ernniuu m ras mwecr er mia„vamvs a roa w„aunn„ar nas vl+acer av AOR APPROVED LIQUID APPLIED VAPOR NEW DRYER VENT TO TRUE BARRIER OVER 4'PLYWOOD AT EXTERIOR; EXTERIOR w/GRAVITY NORTH PROVIDE 3.5"CLOSED CELL SPRAY FOAM 74"STEP 1 DAMPER o DETAILS INSULATION FOR R24.5 (15.) NEW GFI RECEPTACLE FOR PROVIDE NEW FLEX WASHER;COORDINATE AMPERAGE 74'STEP DUCT BRANCH TO NEW RECEPTACLE FOR DRYER; T SHEET NO: 3-0 REGISTER AT CEILING COORDINATE AMPERAGE PROJECT PARTIAL PLAN - MUD ROOM 1"NOSING O NORTH SCALE: = T-O�� NEW QUAD GFI RECEPTACLE A6 SHEET 6 OF 6