HomeMy WebLinkAbout50289-Z o�sUFfat4keo. TOWN OF SOUTHOLD aye BUILDING DEPARTMENT coTOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50289 Date: 2/2/2024 Permission is hereby granted to: DeSantis, Paul 560 Deer Dr Mattituck, NY 11952 To: Install roof mounted solar panels to an existing single-family dwelling as applied for per manufacturers specifications. At premises located at: a �7 560 Deer Dr, Mattituck vD Nb�' i n5- od)ed SCTM #473889 5 Gbq Sec/Block/Lot# 114.40-4 Pursuant to application dated 1/8/2024 and approved by the Building Inspector. To expire on 8/3/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-RESIDENTIAL $100.00 Total: $325.00 Building Inspector SOUTyO� # TOWN OF SOUTHOLD BUILDING DEPT. o►�� 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND . [ ] -INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION-, - [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: F) . I I r DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS [ V ! ro . G � FOUNDATION (1ST) N H ------------------------------------ cl FOUNDATION (2ND) V1 0 ,Hu ROUGH FRAMING& PLUMBING Cb 1 r INSULATION PER N.Y. y STATE ENERGY CODE FINAL ADDITIONAL COMM NTS S r• Ptl ft-4 O L S O v1 z 4eh l Y lr 1 ro o z x x d ro H t sg��co� oy TOWN OF S®gJ71'HO L1iD —BUILDING DEPARTMENT w =, Town lull Annex 54375 Main Road P. ®. Box 1179 Southold NY 1 1 97 1-0959 �y • a Telephone (631) 765-1802 Fax (631) 765-9502 https:,fAv w.soectholdtowlanv.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ® E C E E PERMIT NO. 5��B Building Inspector:_ l j ib JAN ` 9 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. where the Applicant is not the owner,an Bull finq Depnr!ment Owner's Authorization form(page 2)shall be completed. TO" Of Southold ®ate: OWNER(S)OF PROPERTY: Name: LEA i6s- -vk-) TS-CTM #10o0- y 00 -- 00 00V Project Address: b �Y ' Phone#: G 3 1- 3 9 2 - -7 0q I Email: �b a Mailing Address: �56 0 -b f--c - br. CONTACT PERSON Name: Mailing Address: -7410 SOLAR d avY,) Mo-,4 4 1 �, Phone#: (D 7Jd 3 9 9 .-7 0 q / Email: Pe-,+rIY3)4,,5 e, if,a's � , cc,k' DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFOI88liIATI011lio. Name: ed e,l)')edrl Y)f-ro C., Mailing Address: Phone#: 3 . cJ D I Email: ptrell4sG' CO'L's 's I Gdm DESCRIPTION OF PROPOSED C®NSTRUCgION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition�i Estimated Cost of Project: ther �n5 -a d So )a.r PU 5q S$ti-M �4P `1.LgS y r9 c3�-H e OLA -J , $ �'l), 11 0, Will the lot be re-graded? ❑Yes;KNo Will excess fill be removed from premises? ❑YesN32!iVo n t�del eS 0 CR 11 G2 kl� -1>LA-0 8 l L' (. ' /O 4- J s &U I r PROPERTY INFORMATION Existing use of property: + �„ Q Intended use of property: 1 � Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to kz"1 this property? ❑Yes b IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by. §dinance pter236 of the Town Code.APPLICATION IS HEREBY MADE to the.Building Department for the issuance of a Building Permit pursuant to the Building Zone of the Town of Southold,Suffolk,County,New York and other applicable,Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print lQ name):` L�1r-ro�'�U b.9�� � authorized Agent ❑Owner Signature of Applicant:< Vut. � -X-C4 A/N Date: STATE OF NEW YORK) SS: COUNTY OF ul., I ) Lo '`� � ''"'r®`-' being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Y (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this f/21 day of C. 20 02� 4oliKyPublic LOUIS J ROMEO Notary Public, 06314813wYork N 01 PROPERTY OWNER AUTHORIZATION Qualified in Suffolk County (Where the applicant is not the owner Commission Expires November 17,20Zb PP ) I, D Yl(�`• � 5 residing at�S lD 0 -be-f_r- A44,}tea 104 5 0� do hereby authorize ELtyryQ,A_4- n L L. C., Dl to apply on my behalf to the Town of outhold Building Department for approval as described herein. Owner's Signature 2-U ( 23,Date LeNVY)e 1 nn Print Owner's Name 2 Yank workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART i.To be completed by NYS disability and Paid,Family Leave benefits carrier or licensed insurance agent of that came 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured Work Location of Insured?Only re i fired if coverage is or Social Security Number ( Y 4 ag speciNcaliylirMted to certain locations in New York State,te.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier {Entity Being Listed as the Certificate]colder) TOWN OF SOUTFiOLD ShelterPoint Life Insurance Company 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"W SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/01/2023 to 12/31/2024 4. Policy provides the following benefits- ® A-Both disability and paid family leave benefits. S.Disability benefits only. C.Paid family leave benefits only- Policy covers: ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the fallowing class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized repmeseritative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability,andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By w4a,UI/ (Signature of insurance carrier's authorized representative or NYS Licensed Imurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Exectrlive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authored representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd,a of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 6200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only If Box 46,4C or 50 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Artiale 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers ficensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Fcrm OB-120.1.Insurance brokers are NOT authorized to issue this form D8.120.1 (12-21' ��I���III1111111�1�119�1iii11111111�(1 A`C)RE0� CERTIFICATE OF LIABILITY INSURANCE DATE I M 7/M 1rpo 120! THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: H the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER clr ROBERT S.FEDE INSURANCE AGENCY A. PHONE 631-385-1 76v FAX 23 GREEN STREET,SUITE 102 No Eat. Nu HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSU S AFFORDING COVERAGE NAIC 0 xw�A:ATLANTIC CASUALTY INS.CO. 524210 INSURED Element Energy LLC INSURER B' DBA ELEMENT ENERGY SYSTEMS GENERAL S INsuRr�c` 61434 7470 SOUND AVENUE INSURER O MATTITUCK,NY 11952 VISIR2ERE: INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, 1LTR TYPE OF INSURANCE VJVD POLICY NUMBER (MICR EFF u EXP LIMITS COMMERCIAL GENERALLULBILTfY L1460036873 AX X 7/14/2023 7/14/2024 EACH OCCURRENCE $ 3,000,000 CLAIMS MADE IX-1OCCUR PREMISES aacunenae S 100,000 LMA3892038 MED EXP(An are person) $ 5000 X Contractual Lia 7/19/2022 7/19/2024 PERSONAL a AOV INJURY s 3000000 GEN'LAGGREGATELIMITAPPLIESPER GENERAL AGGREGATE $ 3,000,000 PRO- POLICY X JECT LOC PRODUCTS-COMPIOP AGG S OTHER: s AUTOMOBILE LWeUA Y UO—WINEDSINGLE LIMIT : ANY AUTO BODILY NVJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY BODILY INJURY(per acddent) S HIRED N N PRT�l DAMAGE 3 AUTOS ONLY AUTOS UTOS ONLYLY PROPE $ *1E BRELLA LIAB OCCUR EACH OCCURRENCE $ ESS LIAB CLAIMS-MADE AGGREGATE $ RETFMICN$ $ WORKERS CGMPENSATION 124494445 PEq ER AND EMPLOYERS*LIABLITY ANY PRCPREETORIPARTNERiEXECUTIVE YIN 7/1X023 7/1312024 T B OFFICERA MMSER EXCLUDED? —1 NIA I-L EACH ACCIDENT $ 1(}QQ QQQ J11andataq in NH) If yes,desaibe under EL DISEASE-FA EMPLOYE $ DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMB $ NY State DBL DBL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OP OPERATIONS f LOCATIONS I VEHICLES(ACORD 101,Addllonal Remarks schedule,may be alfaahM I pore space Is rewred) CERTIFICATE HOLDER IS ADDMNAL INSURED Certticate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHCRIM REPRESENTATIVE RQbeft S- Fede, C 1988-2015 ACORD CORPORATION. All rights reserved. AP'non 7S 17A4AlAil Thn arson.....„„.,,,,N 1.......,.,,..,.,.:ap„a,,.�. -.L,--4 Ar11Gn NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 122C6 1 nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) _91 IF AAAAAA 823336604 = ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTI[TUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 369075 07/13/2023 TO 07/13/2024 711U2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS'IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY.INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS;lIWWW.NYSIF.COMICERTICERTIAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT 4ZCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING ,s 'Rood APPROVED AS NOTED DATE;a-a"a B.R# 28�1 COMPLY WITH ALL CODES OF FE a00 -00 BY: NEW YORK STATE&TOWN CODES REQUIRED AND CONDITIONS OF NOTIFY BUILDING DEPARTMENT AT SOUTHOIDTOWN ZBA 631-765-1802 SAM TO 4PM FOR THE $OUIHOLD TOWN PUWNING BMFOLLOWING INSPECTIONS: FOUNDATION-TWO REQUIRED SOUMTCWNTUTa FOR POURED CONCRETE X NXI DX ROUGH-FRAMING&PLUMBING Sou 0wHpG INSULATION SCHD FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELECTRICAL YORK STATE. NOT RESPONSIBLE FOR INSPECTION REQUIRED DESIGN OR CONSTRUCTION ERRORS -x Q(5cony-vcA Imu5jr be loco-4-ca Additional ou+Si CIS Certification 1{a be W a� Y PG d � May Be Required. a CCU �.....�.Mr* - o �Cl ELEMENT ENERGY 9Y9TL"M8 CUSTOMER VISIT CHECKLIST,QUESTIONS AND INFORMATION SHEET Signer r fSame as Drivers Lrbeme) S.ynor 2(Sam as Drivers Licaun) Customer Name(s) L614 4 O E$ U L #A 11 Email Address W� Email Address Mobile Phone 31 V - qS�- Mobile Phone Project Location: 0000---- Township of: J (�� �J S1.DOB: S2.DOB: All Project D_qXs Checklist: Additional Pr ecf based Notes and tans: �J How Much do you Know about solar so far?Why do you want solar? S Pq \0�A�JReview how Solar Works and Stores Energy and saves money ►eri kJ me rip Review Electric Bill and haw much power they use �t�Q f�'�C JQ�- V�uyGer, Find out Exact Electric Usage for Building,bill with the bar graphs(CALL) 6�- , /G / / LJ r Q L Show printed example of How solar works(which column) may be 0. (f_�f_[J� I K W� 14 �k e "Tt/I f-R Review Electric Rates and Increases with the Electric GRID picture � Review of Incentives and Credits and how they work If they like the idea of solar,Look over the Property Make a copy or photos of both sides of the electric bill Photos showing the outside of the house tram all sides(from far back) Photos of the electric meter and meter number(AII photos&far back) ) Photos of the Main and sub Panels in the house and panel label(AII Pho /� I Photos above electric Panel where wires arej_ �, q!!"WAp ( Photo of Beams in the attic and measurements of the beams(L,h,w) Roe, LL' Answer any questions comments or concerns so far ` Set Up a time fora return visit Date I L- 'Qa Time '7,`)I 1 ' /`� Q Photo of Tax Bill or Deed l 1 Find Out If(money down)Works for Customer,If Anything At All f. p . 3d Additional Notes on Any Specific Items l L.�-W'4 DE 5AMT1 S NAME ON ELECTRIC BILL: ,�r Proper Propo . AUL DIE 14/V'7 5 Look over any items in question(ie roof or vents or conduit) CUSTOMER ID# Review Layout of Modules,and Production of Each 6 9 j—3609-4d--5- See which Option the Customer Wants to See First CUSTOMER ACCOUNT# bl[y/a ���� [l Review Costs and Design Line by Line -! 70 See which Option the customer likes best See if the Customer can Quality for the Solar Electric Next steps,(Timeline.Applications, eslg tamps,PE.Plans, state) Schedule Welcome c 4410 Time: 3,1 S CALCULATIONS: Further Info: Average Total Kwh/YEAR 1 Proposal Completed !-Designs Layout Initialed vera e Total$/YEAR 3 9a t J Production Report Initialed � ii Installation Contract Completed Agent Authorization Completed NEW Estimated Kwh/YEAR Deposit Check(If Lease:Deposit must match contract) Congratulations Next Steps Review,(Call from,paperwork,Signatures,Timeline) In Office; Click Button in CRM for next step Additional Notes Scan Complete Contract Files Into the Drive Folder Scan Checklist,Bills,Tax Docs,Surveys,and others into Drive Folder Print and Sign Complete Cam Sheet Email Sun Advisor Manager Complete Cam Agreement worksheet ov Pass on All Stapled Paperwork Package to Manager(on desk) Loan Approval p SAC, Element Energy LLC,7470 Sound Ave,Madituck.NY f1952 1 Loan Approval ll (63 f)779-7993 1 e2sys com S13 f to-f0-20 SOLAR-BATTERY-GENERATORS-ROOFING XR Rails .Q., XR10 Rail XR1000 Raill Bonded Splices XN 54 A A low-profile mounting rail , The ultimate residential I A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability 12'spanning capability - Self-drilling screws • Moderate load capability Heavy load'capability Extreme load capability - Varying versions for rails • Clear and black finish Clear and black finish Clear anodized finish - Forms secure bonding Clamps & Grounding (? bFC)s Stopper silee'ves Grounding Lugs Mlicroinverter Kits jY sA Universal Fastening Objects Snap onto the UFO to turn ys to Mount Mis or POs to XR bond modules to rails. into a bonded end clamp. equipment ground.-- Rails. • Fully assembled & lubed Bonds modules to rails - Low profile - Bonds devices to rails • Single, universal size Sized to match modules - Single tool installation - Kit comes assembled • Clear and black finish Clear and black finish - Mounts in any direction - Listed to UL 2703 Attachments t-�' � - V%f— FilashFoort2 Conduit Mount Bonding Hardware X 1.5­1,KA Flash and mount XR Rails Flas d mount conduit, esign for rapid rail Bond and attach XR Rails with superior waterproofing. ut, or junction boxes. attachment. to roof attachments. • Tlivist-on Cap easesinsrai-11' - Twist-on Cap eases install * Secure rail connections - T&Square Bolt options • Wind-driven rain tested - Wind-driven rain tested - Slot for vertical adjusting . Nut uses 7/16"socket • Mill and black finish - Secures 3/4"or 1"conduit - Clear and black finish - Assembled and lubricated Resources Design Assistant NAECEP Certified Training Go from rough layout to fully Earn free continuing education credits, engineered system. For free. while learning more about our systems. Go to Iron Ridge.c orn/design \W�W` Go to IronRidge.corn/training IRON RI DGE Flush Mount System --� s. . kr ,a'�•.„- �` :psi-ca"',`-.�`` .xx � .,,..;�' ,��- .?-� f:.7t -�%-'3s;_"". �,__ _ - _ ;lac:nr-U- - - -yY�"i.'s"::'i=-'a::�-l:.rr,_�.c','=-:.;s '-^_"�:.:�_-_if -`IPsrz-�.-,•'"F = NU Built for solar's toughest roof. IronPidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fare fading Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. MECHANICAL SPECIFICATION 3n.?t 74.0in x 41 lln x 1.26 iri(including frarne) (1879 mm x 1045 mm.x 32 mm) 74.0-(1629-) sa W9asmm) 48.5lbs(22.0 kg) _ - __ -y r,? �• 0.13in(3.2 mm)thermally pre-stressed glass with sr ___ anti-reflection technology 4•amne49Pmm°aJr(4smm) Fe°e sr Composite film - sea(see°m) _ r - Black anodized aluminum I 41Y!m4smn) 6 x 22 monocrystalline Q.ANTUM solar half cells 2.0g-3.98in,x 1.20-2.304n A 0.59-0.711rt -_ ---- --- -- -- - -- -------..---- (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes_ J a9z u�W-) - - Cea'e 4mm2 Solar cable;(+)J_49.2 in(1250 min),(-)J_49.2 in(1250mm) •.�--•�.-.��- _ 4•Ma.f 9IJ-(DETALA) ? G-a-a :--oF Staubli MC4;IP68 Uj UTAILA O.fi3'llamm) 0.96'(24.5mm)I�I03T(fl5mm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 - 400 ---- 405 . _'�'�a y,:,?s_, ..-..�-.---.. ..-':%'•tom ., ifi:_�T�'_L:4r''i:. �,. -.;tti; �- - at{ PUFF [W] 385 390 395 400 - 405 isc [A] 11.04 11.07 11.10 11.14 11.17 ��ii'CLI:•/�liat}c' Voc IV] 45.19 45.23 45.27 45.30 45.34 '.! at;Lf;%y - IMPP - -[A]- - -- 10.59 10.65 10.71 10.77 - 10.83 ', ,t ;_l,vno VMFP IV] 36.36 36.62 36.88 3713 37.39 >_19.6 -- J_19.9' >_20.1 - 2!20.4 >20.6 PMPF [W] 288.8 292.6 296.3 300.1 303.8 �IsC--- -[Aj - 8.90 --- 8.92 8.95 8.97 9.00- Voc (VI 42.62 42.65 42.69 42.72 42.76 IMPP [A] 8.35 8.41 8.46 8.51 8.57 VMFP -- IV] - 34.59 34.81 3503---- 35.25 35.46 ',Measurement tolerances PMFP t3%;Isc;Vac t5%at STC:ICC0 W/m2,25t2°C,AM 1.5 according to IEC 6C9C4-3.2800 W/m7,NMOT,spectrum AM 1.5 - - - 0 CELLS PERFORMANCE WARRANTY -- PERFORMANCEAT LOUD IRRADIANCE i At Icast 08%of nominal owcr durin a °may P 9 '0 first year.Thereafter max.0.5% 2 - __�___-_ _ degradation per�ar.Atleast93.5% - i of nominal power up to 10 years.At r jqk least 86%of nominal power up to - -----`-- --J------ ---- --- - ; -, 25years. = 9a`--- ----•---- � z All data within measurement toleranc- --- - - es.Full warranties in accordance with - °0 goo eaa am moo 0 ii. the warranty terms of the Q CELLS ,.,, sales organisation of your respective country. e s�asa,a�.mm�.r.em,m_ow�Fm°, _>a Typical module performance under law Irradiance conditions in comparison To STC conditions(25'C,1000W/m2) m CO TEMPERATURE COEFFICIENTS _ [%/K] _-+0.04 _' a _.---- p [%/K] -0.27 y [%/K] - -0.34 Mod.,--is .__ NMOT [°F] 109±5.4(43±3°C) m- PROPERTIES FOR SYSTEM DESIGN w a t=_'timurr S/-,azn 5?ofls-,'z Yjts [V] 1000(IEC)/1000(UL) Pli->'c^:!3 c;ossii's:e.)•: Class II o 1,16"0mum 3,3633 Fuze Ratog [A DC] 20 F i r a 8a'i:,?g b a z sd cn AAi311 L_817;J0 TYPE 2 Ld !Na;t.3saigra_ad,Fvs^rl iI' [Ibs/ft'] 75(360OPa)/55(266OPa) =sr^;tcadd3iar3il=_Te;;tos-atnra -407upto+185°F p dlax.Tas'et cad,Push till' [lbs/ftq 113(5400 Pa)/84(4000 Pa) °'''CnrriinLausOuty (-40°Cupto+85°C) m m PP 'See Installation Manual t U (QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION m - _- P UL 61730,CE-cam lient, C 1 O m Quality Ccntralled PV-TUV Rheinland, 0_Q, I4aHcI m e IEC 61215:2016,IEC 61730:2016, "//�� -- -- -------- " U.S.Patent No.9,893,215(solar cells), 76.4 in 43.3 in 48.0 in 1656lbs 24 24 32 QCPV Certifica(icn cngoing. G US 1940mm 1100mm 1220mm 751kg pallets pallets modules C.- - -•-•. 'U L'L al)3a la rrr't IIOZ)) ---.•.-__._-.--______-.._.----_-.-_.__._--.__._ __-- ._ ..___._-._- (1 y Not®:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwrha 0 CELLS Am arlce Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748 59 96 1 EMAI L inquiry@us.a-cells.com I INES www.q-cells.us powered by s A ` • pYR `. ki 51 1- II' -�Q Q�•' / :i r,,.maave Warranty ®CELLS Product 3 PeAcr•nxcg yield security T BREAKING THE 20%EFFICIENCY BARRIER nnn/III Illlllnlllllll IIII Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. TH E MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY C?; Optimal yields,whatever the weather with excellent low-light and temperature behavior. )z ENDURINGHIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID Technology',Hot-Spot Protect and Traceable Quality Tra.QTm. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). �J A RELIABLE INVESTMENT (� �� Inclusive 25-year product warranty and 25-year 1 linear performance warrantyz. 'APT test conditions according to IEC/TS 62804-1:2015,method A(-1500 V,96h) See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on . residential buildings Allilliffillk Engineered In Germany CELLS IQ8 and IQ8+ Microinverters INPUT,1 1 Commonly used module pairings' w 335=350 235-440 Module cam atibilit 6C=cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 P Y half-cell MPPT voltage range v _ 27,737 29-45 Operating range v 25-48 25-58 Min/max start voltage v 30/48 30/58 Max input DC voltage V 50 60 Max DC current2(module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA Q PV array configuration 1x1 Ungrounded array*,No additional DC side protection required;AC side protection requires max 20A per branch circuit �PU7PUT ITATA� A ,1 Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range" V 240/211-264 Max continuous output current a 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over - 2 3 cycles Arms Max units per20 A(L-L)branch circuit" 16 13 Total harmonic distortion c5% Overvnitagnclass AC part Ill. AC port backfeed current ink 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85leading-0.85lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 _ j 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -40°C#o+60°C(-40°F to+140cF) Relative humidity range 41Y.to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 302 mm(1.2") Weight ;T.08.kg(238;Ibs) Cooling Natural convection-no fans Approved for wet locations Pollution degree PM Enclosure Class II double-insulated;obrrosian resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.ccm/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4,,Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 108SP-DS-0002-01-EN-US-2022-03-17 ENPH SE and 1 + Microinverters Our newest too Microinverters are t4heirr�ery'sfirs�ralierogFist fol�mialax so-nWare- > UC_ftAf9k,*1rajYdcompaa with defined microinverters with spirt-phase powgF com/ersioncapability to convert EEC pkig-n-play cor ens- power to AG power efficiently.The brain of the?serrticonduetor-basedMicroirlVeFter is our proprietary application-specific integrated,circult(ASICYwhichienablbs,the p � a$eln• rd�tisd�or oif '[S"�'E tsefvrreer�co a s. microinverter too � g i f-gridlrrladss..�`k'liscE[igls•�esiFtirl a'�varlcsd 55nFn technology with high speed,digi8al logic andhas•super=fas,responsetirrles pasd instafiats�lrrvlri#Fisun s to changing loads and glad events,allevia+tingconstraintsonibztteryr sizing,fmrhorle - isecafsll energy systems. -==i` :=°mil [ 1adceS:�l;rre�eV tl _ _ ' grid+isdawri"' dry- _ -1�=� I P06ore+�-€ar�al�eiiailhorl>c�lrlsiiative Part of theEnphase Energy System,I08 Series, 102 a-cries lNcroimrerters redefine�rehabiky.• Wicrcinverters integrate vAth the Enphase tQ BatterA standarsfsvf th-more-than�one mi rion cumulative Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- and analysis software. leading IimIted warranty of up to 25 years. ad lced9[ds&3FF(DFV° Remote automatic updates for the ktestgl:idrequkements Connect PV modules quic1dy and easily to I08 Series I08 Series Vicroinverters are UL Listed as P Configufableto support a tide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Doom Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grldl pimn-lee manufacturer's instructions. Meets CA Rule 2'i(UL'1741=SA) requirements O 2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other 'Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. I08 and IQBPius supports split phase,240V iQBSP-03-0002-01-EN-US-2022-03-17 installations only. v Page 1 of 2 01/05/2024 Current enewabfes Element Energy LLC to Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Desantis Residence Project Address: 560 Deer Drive, Mattituck, NY, 11952 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Ult Wind Speed: 135.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 OF NEW yo � oe�RS A. 1'40 Current Renewables Engineering Inc. * �' Professional Engineer Ce info@currentrenewableseng.com ti o m00% 106793 F �Q' Signed on:01/05/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com • J Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x6 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 25 degrees and has a max beam span of 12.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Check 2: Shingle roofing supported by 2x6 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 31 degrees and has a max beam span of 8.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com CODE INFORMATION ROOF MOUNT SOLAR PERMIT PACKAGE THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC L E NA D E SA N T I S POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2020 NEW YORK BUILDING CODE-BUILDING 12. 150 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 NEW YORK BUILDING CODE-RESIDENTIAL 2020 NEW YORK BUILDING CODE-EXISTING BUILDING 2020 NEW YORK BUILDING CODE-PLUMBING 2020 NEW YORK BUILDING CODE-MECHANICAL 560 DEER DR, MATTITUCK, NY 11952 2020 NEW YORK BUILDING CODE-ENERGY CONSERVATION 2020 NEW YORK BUILDING CODE-FUEL GAS 2020 NEW YORK BUILDING CODE-ACCESSIBILITY 2020 NEW YORK FIRE PREVENTION CODE BUILDING INFORMATION 2017 NATIONAL ELECTRICAL CODE THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 2 STORY HOUSE SINGLE FAMILY RESIDENCE METER NO: 98302631 _ EXPRESSLY FORBIDDEN WITHOUT PRIOR FROM URRENT CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U AHJ: SOUTHOLD TOWN WRITTEN APPROVAL RENEWABLES ENGINEERINGERING INC. ROOF: COMP SHINGLE APN: 114104 PV SYSTEM SUMMARY: Current SYSTEM SIZE(DC) STC:405 x 30=12.150kW DC Engineering PTC:381.37 x 30=11.4411 kW DC SYSTEM SIZE(AC) 8.7OOkW AC @ 240V CURRENT RENEWABLES ENGINEERING INC. MODULES (30)HANWHA Q CELLS: Q.PEAK DUO BLK ML-G10+405 P��OF N£w yo 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-005-1733 1NW W.CRENG.CO MICRO-INVERTERS ENPHASE:IQ8PLUS-72-2-US *�a�oOF,EYi A. � �* AERIAL VIEW VICINITY VIEW CONTRACTORINFO MICRO-INVERTERS QTY 30 TILT 25°,25°,31° AZIMUTH 137°,317°, 137° 2 = ,. ROOF COMP SHINGLE �`�p 106793 �� niff RAFTER/TRUSS SIZE 2"X 6"RAFTER @ 16"O.C. -S10NP `.: EP S . ATTACHMENT TYPE QUICKBOLT 17667SS WITH IRONRIDGE XR-100 RAIL Exp:9/30/2025 -MAIN SERVICE PANEL EXISTING 200 AMPS MSP WITH 200 AMPS MAIN STAMPED 01/06/2024 ELEMENT ENERGY LLC. 7470:; SOUND AVENUE,MATTITUCK BREAKER ON TOP FED NEW YORK,11952 INTERCONNECTION LINE SIDE TAP PH:(631)779 7993 ♦ v services@e2sys.com OCPD RATING 50 AMPS c' Licence-ME-52689 j (MASTER ELECTRICIAN) UTILITY PSEGLI r<<.. Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) GENERAL NOTES: +f 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION Solar Individual Permit Package 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED SHEET INDEX LENA DESANTIS 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED- 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 PV-1.0 COVER PAGE 12.15OKW Grid Tied 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS PV-2.1 ROOF PLAN 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL 560 DEER DR, GROUNDING ELECTRODE- PV-3.0 STRUCTURAL MATTITUCK, NY 11952 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS"• PV-4.0 ELECTRICAL KID Rev Description Date 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" PV-5.0 ELECTRICAL SLIDA INITIAL DESIGN vsnoza 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC.• PV-6.0 BOM 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35.• PV-7.0 ELECTRICAL PHOTOS OPPORTUNITY LENADESANTIS 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.• PV-8.0 SIGNAGE PROJECT a67s 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.1 PLACARD DATE DRAWN 116Q024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY.- DRAWN BY E.R 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8"ABOVE ROOF SURFACE. PV-9.0 MICROINVERTER CHART SHEET# PV-1.o 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE;TYPE NM CABLE PV-10.0 SAFETY PLAN ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 1213 CONDUCTORS THROUGH TITLE OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0 SAFETY PLAN 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE COVER PAGE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: PV-12.0+ ISPEC. SHEETS NOTR324.6.1 PATHWAYS: LEGEND G E N D NOT LESS THAN TWO MINIMUM 36 INCH WIDE PATHWAYS ON ENLARGED VIEW C v C I v SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. UM UTILITY METER AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM MSP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE AC DISCONNECT OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR C COMBINER MECHANICAL EQUIPMENT. OF NEW ISO R324.6.2 SETBACK AT RIDGE: �j� ��(,RI A. (,4 ;P � MODULE FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A * * O ROOF OBSTRUCTIONS THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. PROPERTY LINE r COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 LV REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A C7 ly ROOF ACCESS POINT EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A I 1_ 11 3 WRITTEN APPROVAL FROM CURRENT 127 HORIZONTAL RIDGE. — _ _ O �F 106793 �� RENEWABLES ENGINEERING INC. _ rC r_ _ I r— r_ R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELSFESSIONP� AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED _r�rrr�r— THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE Current AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE Exp:9/30/2025 �( PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. t1 Renewables A -PATHWAY ON STREET STAMPED 01/06/2024 Engineering OR DRIVEWAY SIDE OF ROOF I'I B -FIRE ACCESS POINT �' 41 CURRENT IINABLES ENGINEERING INC. WEA0111,47A CHICAGO AVE SUITE Q 1 11 II J-13,RIVERSIDE CA 92507 36"ACCESS PATHWAYS - � 86-3 PHONE: ,+ PHONE:(951)-005-1733 1 I �+ WWW.CRENG.CO 18"ACCESS PATHWAYS (i j CONTRACTOR INFO CD I, I 36"ROOF ACCESS POINT (y) NOTES: r I 1 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED FENCE i ON ACTUAL SITE CONDITION AND ;I ROOF OBSTRUCTION �11 MEASUREMENTS. r (E)MAIN SERVICE PANEL 2-: THE 30 SECOND SHUTDOWN REQUIREMENT IS ' I; INCORPORATED INTO THE 2017 NEC AND UL i-- O � (E) UTILITY METER EPSYS' STANDARD 1741. 301-211 a4 3. EXISTING ROOF VENT SHOULD NOT BE i �' (N)AC DISCONNECT + COVERED. A ELEMENT ENERGY LLC. (N)COMBINER 7470 SOUND AVENUE,MATTITUCK 291�211 I NEW YORK,11952 92 [ 1 �:.:•::.;:.:,: PH:(631)779 7993 services@e2sys.com Licence-ME-52689 i (MASTER ELECTRICIAN) Licence-HI-67461 ' • w . I (SUFFOLK HOME IMPROVEMENT) 49'-1 11 � ..o > ' I Solar Individual Permit Package o ' ROOF LINE 36"ROOF ACCESS POINT LENA DESANTIS 12.150KW Grid Tied Photovoltaic System 128'-611 I DEER DR 560 DEER DR, FENCE GATE MATTITUCK, NY 11952 PROPERTY LINE DEER DR Rev Description Dale A INITIAL DESIGN 1/6/2024 OPPORTUNITY LENADESANTIS PROJECT# 4679 DATE DRAWN 1/6/2024 SITE �113 A�1 -0�' DRAWN BY E.R 1 SHEET# PV-2.0 TITLE SCALE: 21 = SITE PLAN ARRAY AREA LEGEND EAVE TO ROOF TOTAL #OF RIDGE ARRAY AREA ROOF AREA AREA ROOF ROOF TYPE AZIMUTH MODULES DIMENSION (Sq.Ft.) AREA COVERED BY COVERED BY (Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) uM UTILITY METER #1 COMP SHINGLE 137 10 11.58 211.20 1853 11.40 #2 COMP SHINGLE 1 317 10 14.16 211.20 1853 11.40 34.19 MSP MAIN SERVICE PANEL #3 COMP SHINGLE 137 10 7.83 211.20 1853 1 11.40 AC DISCONNECT COMBINER aMODULE O ROOF OBSTRUCTIONS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (N)#30 HANWHA Q CELLS: Q.PEAK DUO BLK ML-G10+405 Current ROOF#2F Renewab e (E)MAIN SERVICE PANEL Engineering CURRENT RENEWABLES (E) UTILITY METER UM O ENGINEERING 1760 CHICAGO AVE SUITE (N)AC DISCONNECT AC PHONE: E:(951IDE-1733CA 7 PHONE:(951)A05-1733 WWW.CRENG.CO (N)COMBINER C OF NEW y CONTRACTOR INFO 1 1_611 E `..SYS&_ 106793 ELEMENT��� 3' A'�OFESSI 7470 SOUND AVENUE,MATTITUCK NEW YORK,11952 31 Exp:9/30/2025 PH:(631)779 7993 STAMPED 01/06/2024 services@e2sys.com Licence-ME-52689 ROOF#1 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) ROOF#3 Solar Individual Permit Package LENA DESANTIS STRUCTURAL NOTES : 12.150KW Grid Tied DEER DR 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE Photovoltaic System COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE 560 PROPOSED PV INSTALLATION ONLY. DEER DR, 2.THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. MATTITITUCK, NY 11952 3. PV MODULES, RACKING,AND ATTACHMENT COMPONENTS Rev Description Date MUST FOLLOW MANUFACTURER GUIDELINES AND A INITIAL DESIGN 1/612024 REQUIREMENTS. 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. OPPORTUNITY LENADESANTIS 5. PRIOR TO COMMENCEMENT OF WORK,THE SOLAR PROJECT# 4679 INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE DATE DRAWN 11&2024 2 ROOF PLAN INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY DRAWN BY E.R INCONSISTENCY BETWEEN SITE VERIFICATION AND SHEET# PV-2.1 FOLLOWING:2x6 RAFTERS @ 16" OC SPACING WITH MAX TITLE SCALE: 1/811 = 1'-0" UNSUPPORTED SPAN EQUAL OR LESS THAN 12 FT. ROOF PLAN ROOF ROOF ROOFING NO. OF FRAMING FRAMING OC PENETRATION MAX MAX NO TILT TYPE ATTACHMENT TYPE STORIES TYPE SIZE SPACING PATTERN PENETRATION SPACING OVERHANG ROOF 1 25 COMP SHINGLE QUICKBOLT 17667SS 2 RAFTER 2" X 6" 16" STAGGERED 64" ROOF 2 25 COMP SHINGLE QUICKBOLT 17667SS 2 RAFTER 21' X 6" 16" STAGGERED 64" 2411 ROOF 3 31 COMP SHINGLE QUICKBOLT 17667SS 2 RAFTER 2" X 6" 16" STAGGERED 64" WIND SPEED 135 SNOW LOAD 25 EXPOSURE CATEGORY C THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current R.enewables Engineering TABLE : PENETRATION CURRENT GUIDE FOR INSTALL ENGNEERINGINCABLES 1760 CHICAGO AVE SUITE TWO OR MORE ROW OF PANELS J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.CRENG.CO PV MODULE _ _ _ CONTRACTOR INFO SEE(17678) I I I I I I I I I I I I I I I I I I I I FOR ENLARGED T_ —r— —I a 0 VIEW ",rap. 6Rp (E)COMP SHINGLE ROOF STACKED STAGGERED FULLY STAGGERED ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK ONE ROW OF PANELS NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 1 ATTACHMENT DETAIL SIDE VIEW w,D (MASTER SCALE:Nrs Lic nc a ELECTRICIAN) PV MODULES I I I I I (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package IRONRIDGE XR100 RAIL STACKED/STAGGERED FULLY STAGGERED LENA DESANTIS QUICKBOLT 17667SS ASSEMBLY 12.150KW Grid Tied Photovoltaic System WASHERj�'x '',EPDM ,��,Of NEW y 560 DEER DR, BONDED SS FLASHING,5/16"x 3" .`Q R1 A. Off, MATTITUCK, NY 11952 COMP SHINGLE Rev Description Date A INITIALDESIGN 1/6/2024 r Cl= Lu 2'X 6'RAFTER @ 16'O.C. �^_ Z OPPORTUNITY LENA DESANTIS 106793 C�� PROJECT# 4679 QMPV 0 HEX WASHER A�Or ESS DATE DRAWN v6/2oza DRAWN BY E.R HEAD 11,-18X8", Exp:9/30/2025 SHEET# Pv-3.0 2 ATTACHMENT DETAIL ENLARGED VIEW TITLE wan SCALE:Nrs STAMPED 01/06/2024 STRUCTURAL BACKFEED FUSE SIZING METER NUMBER 98302631 MAX.CONTINUOUS OUTPUT 1.21A @ 240V ACC. NUMBER 9617022904 36.30 X 1.25 = 45.38AMPS 50A FUSES-OK ��pF NEWY C-, OOE M�/Rv O'Q (E)UTILITY METER (N)ENPHASE n D W MAIN SERVICE PANEL COMBINER BOX MODEL 2 099128 ? 1PH,1201240V 60HZ NO#X2-IQ-AM1-240-4/4C N �O 4 (E)2DOA/2P MAIN A CTRIC BREAKER CELL WIRE LESS Rp 3S10NP�' (TOP FED) MODEM COMMS THESE DRAWINGS ARE SUBJECT TO (10)IQBPLUS-72-2-US COPYRIGHT PROTECTION BY US LAW. MICROINVERTERS STAMPED 01/06/2024 REPRODUCTION IN ANY FORM IS IQ GATEWAY EXPRESSLY FORBIDDEN WITHOUT PRIOR BRANCH4ER WRITTEN APPROVAL FROM CURRENT 10 HANWHA Q CEL m RENEWABLES ENGINEERING INC. DUO BLK ML-Gr 1 (N)60AFUSED (10)IQBPL 1 IIAC DISCONNECTMICROI I (N)zoA� I I • CurrentSQUARE D D322NRB (N)LINESIDE TAP VIA UL(N)20A/i� I I WITH50AFUSES, . LISTED CONNECTOR RenewaWes BRANCH- KNIFEBLADE, 10HANWHA Q CEL LOCKABLE,NEMA 3R, Engineering DUO BLK ML-Gr I J(N;)20;A�� i i UL LISTED I I I (10)IQ8PLUS-72-2-US I — -----_ I I qfb .� OVERHEAD UTILITY CURRENTRENEWABLES MICROINVERTERS [— ---- L---------- --- qfb ---- — -- • ENGINEERING INC. EED 16o HCAGGO AVE SUITE ------------------- ---- III 1 -- J-13,RIVERSIDE CA 92507 BRANCH-3 I PHONE: W W W CRENG.CO 1733 10 HANWHA Q CELLS:Q.PEAK DUO BLKML-G10+405 Nf r 6-#10AWG,THWN-2 3-#8 AWG,THWN 3-#6 AWG,THWN ------ CONTRACTORINFO J 1-#10 EGC,THWN-2 1-#8 EGC,THWN 1-98 EGC,THWN IN 3/4"PVC CONDUIT IN 3/4"OR LARGER PVC IN 3/4"OR LARGER PVC CONDUIT CONDUIT (E)GROUNDING ELECTRODE 2-#10 AWG ENPHASE Q-CABLE CONDUCTOR 96 BARE COPPER 1-#6 AWG,BARE COPPER GROUND EE SYS, MODULE INFO MAKE/MODEL HANWHA Q CELLS: DUO BLK ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK ML-G10+405+405 VOC 45.34V NEW YORK,11952 VMP 37.39V NOTE: PH:(631)779 7993 com ISC 11.17A 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS services---ME-5 689 IMP 10.83A AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. STC RATING 405 W 2 ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH (MASTER ELECTRICIAN) ) Licence-HI-67461 PTC RATING 381.37 W PROPER JUNCTION BOX AT EACH END PER 690.31A (SUFFOLK HOME IMPROVEMENT) WIRE SCHEDULE Solar Individual Permit Package STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM LENA DESANTIS AWG CURRENT FACTOR FOR ADJUSTED CURRENT RACEWAY CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO # QTY. SIZE AMPACITY RATING(°C) CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS 12.150KW Grid Tied 310.15(B)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY Photovoltaic System 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 10 40 90° 11.17 0.96 1 38.40 13.96 560 DEER DR, MATTITUCK, NY 11952 3 AC MICROINVERTER TO COMBINER EXTERIOR WALL 6 10 40 90° 12.10 0.96 0.8 30.72 15.13 Rev Description Date 4 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 36.30 0.96 1 52.80 45.38 A INITIAL DESIGN 1/M024 5 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 900 36.30 0.96 1 72.00 45.38 OPPORTUNITY LENA DESANTIS PROJECT# 4679 DATE DRAWN 1/6/2024 DRAWN BY E.R SHEET# PV-4.0 TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING METER NUMBER 98302631 MAX.CONTINUOUS OUTPUT 1.21A @ 240V ACC. NUMBER 9617022904 36.30 X 1.25 = 45.38AMPS 50A FUSES-OK _�OF NEw y OP oo� wi,Qv O C •p �* Ujr; D W (E)UTILITY METER 0 (N)ENPHASE 2 099128 2 (E)200A RATED MAIN SERVICE PANEL .COMBINER BOX MODEL N �� 1 PH,120/240V 60HZ NO#X2-IQ-AM1-240-4/4C �� CTRICP� AjQOSS1ONQ�. (E)200A/2P MAIN BREAKER THESE DRAWINGS ARE SUBJECT TO ?NA WIRE LESS (TOP FED) COPYRIGHT PROTECTION BY US LAW. (10)IQ8PLUS-72-2-US COMMS STAMPED 01/06/2024 REPRODUCTION IN ANY FORM IS MICROINVERTERS EXPRESSLY FORBIDDEN WITHOUT PRIOR TEWAY WRITTEN APPROVAL FROM CURRENT BRANCH-1 RENEWABLES ENGINEERING INC. 10 HANWHA Q CELLS:Q.PEAK N DUO BLK ML-G10+405 •(10)IQ8PLUS-72-2-US (N)60A FUSED Current AC DISCONNECTMICROINVERTERS SQUARE D D322NRB IN)LINESIDETAP VIA UL RenewableS WITH 50A FUSES, •�i LISTED CONNECTOR Engineering BRANCH-2 (N)20. KNIFEBLADE, • 10 HANWHA Q CELLS:Q.PEAK N - LOCKABLE,NEMA 3R, .�. DUO BLK ML-G10+405 • (N)2o:� UL LISTED • CURRENT RENEWABLES TO UTILITY (10)IQ8PLUS-72-2-US �b • OVERHEAD ENGINEERING INC. •/�• 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA MICROINVERTERS qfb FEED PHONE: 51)-405-733507 W W W.CRENG.CO BRANCH-3 10 HANWHA Q CELLS:Q.PEAK N CONTRACTOR INFO DUO BLK ML-G10+405 . 6L -#10 AWG,THWN-2 3-#8 AWG,THWN 3-#6 AWG,THWN 1-#10 EGC,THWN-2 1-#8 EGC,THWN 1-#8 EGC,THWN IN 3/4"PVC CONDUIT IN 3/4"OR LARGER PVC IN 3/4"OR LARGER PVC CONDUIT CONDUIT (E)GROUNDING ELECTRODE nA do 2-#10 AWG ENPHASE Q-CABLE CONDUCTOR#6 BARE COPPER ��..iL�. 1-#6 AWG,BARE COPPER GROUND E2SS�. MODULE INFO ELEMENT ENERGY LLC. MAKE/MODEL HANWHA Q CELLS: Q.PEAK DUO BLK 7470 SOUND AVENUE,MATTITUCK ML-G10+405 NEW YORK,11952 VOC 45.34V PH:(637)779 7993 VMP 37.39V NOTE: services@e2sys.com ISC 11.17A 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS Licence-ME-52689 IMP 10.83A AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. (MASTER ELECTRICIAN) STC RATING 405 W 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Licence-HI-67461 PTC RATING 381.37 W PROPER JUNCTION BOX AT EACH END PER 690.31A (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package WIRE SCHEDULE LENA DESANTIS STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM AWG CURRENT FACTOR FOR ADJUSTED CURRENT RACEWAY CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION 12.150KW Grid Tied EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO # QTY. SIZE AMP RATING(°C) CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS Photovoltaic System 310.15(B)(1B)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY 560 DEER DR, 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 10 40 90° 11.17 0.96 1 38.40 13.96 MATTITUCK, NY 11952 3 AC MICROINVERTER TO COMBINER EXTERIOR WALL 6 10 40 90° 12.10 0.96 0.8 30.72 15.13 Rev Description Date A INITIAL DESIGN 1/6I2024 4 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90, 36.30 0.96 1 52.80 45.38 5 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 36.30 0.96 1 72.00 45.38 OPPORTUNITY LENADESANTIS PROJECT# 4679 DATE DRAWN 1/6/2024 DRAWN BY E.R SHEET# PV-5.0 TITLE ELECTRICAL SLD MATERIAL LIST ELECTRICAL EQUIPMENTS QTY. PART PART# DESCRIPTION 30 MODULE Q.PEAK DUO BLK ML-G10+405 HANWHA Q CELLS: Q.PEAK DUO BLK ML-G10+405 30 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US 240V 1 AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 3R UL LISTED 1 ,COMBINER X2-IQ-AM1-2404 ENPHASE COMBINER BOX X2-IQ-AM1-240-4 2 TAP CONNECTORS [PC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR _ WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. BREAKER AND FUSES QTY. PART PART# DESCRIPTION Current 1 FUSES 50A FUSES GENERAL 50A FUSES Renewabl-es 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 W W W.CRENG.CO CONTRACTORINFO RACKING QTY. PART PART# DESCRIPTION 34 RAIL XR-100-168B XR100, RAIL 168" (14 FEET) BLACK a . --== 16 SPLICE XR100-BOSS-01-M1 BONDED SPLICE, XR100 CESYS! 42 MID CLAMP UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK ••• 36 END CLAMP UFO-STP-35MM-B1 STOPPER SLEEVE, 35MM, BLACK 104 FLASHING 17667SS QUICKBOLT ELEMENT ENERGY LLC. 9 GROUNDING LUG XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 7470 SOUND AVENUE,MATTITUCK NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package LENA DESANTIS 12.150KW Grid Tied Photovoltaic System 560 DEER DR, of: NEW, MATTITUCK, NY 11952 �P Q�MAb/ 0 Rev Description Date �O "�i A INITIAL DESIGN 1/6I2024 n W fi 09912B Z OPPORTUNITY LENA DESANTIS ` PROJECT 4679 N�OA CTRICP_�` � DATE DRAWN 1/6/2024 S10`P DRAWN BY E.R STAMPED 01/06/2024 SHEET# PV-6.0 TITLE BOM EXISTING SERVICE PANEL PHOTOS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current RenewaF = Engineering pF NElyY a `Q O�MA/�j 0.Q CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE 4/ = J-13,RIVERSIDE CA 92507 r— PHONE(951).405-1733 tier m W WWW.CRENG.CO 099128 2 CONTRACTORINFO O '<i crR1cP� � SS1oNP� STAMPED 01/0612024 s aagr— E2c;Yc;.i ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK tl NEW YORK,11952 t. .a• PH:(631)779 7993 c ,y_ tt' services@e2sys.com ? Licence-ME-52689 $ (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package y LENA DESANTIS 12.150KW Grid Tied Photovoltaic System 560 DEER DR, A MATTITUCK, NY 11952 Rev Description I Date 1 A INITIAL DESIGN 1 1/6/2024 1 OPPORTUNITY LENA DESANTIS PROJECT# 4679 DATE DRAWN 1/6/2024 r DRAWN BY E R SHEET# PV-7.0 TITLE ELECTRICAL PHOTOS PHOTOVOLTAIC — M ��pF NEINY 690.12 E M ClA/V7�CQ,Q� m osslza 2 ` THESE DRAWINGS ARE SUBJECT TO L — - O CTRIC COPYRIGHT PROTECTION BY US LAW. TURN RAPIDY FORM IS ARoFESs1oNP� EXPRESSLY REPRODUCT FORBIDION IN DEN N WITHOUT PRIOR SHUTDOWN SWITCH TO RATED AC OUTPUT - - 36.30 - WRITTEN APPROVAL FROM CURRENT .- � OPERATING- � VOLTAGE � � VOLTSSTAMPED 01/06I2024 RENEWABLES ENGINEERING INC. THE "OFF" POSITION TO AC A SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Current AND REDUCE SHOCK WARN Renewables HAZARD IN THE ARRAY P M - - Engineering 690.56(C)(1)(B) -SOURCECES SECOND PHOTO-VOLTAIC SYSTEMCURRENT RENEWABLES ' OUTPUT ENGINEERING INC. RATED CURRENT 36.30 - 1760 CHICAGO AVE SUITE r •■MAL • ■ ■ATING •LTAGE - , , PHONE 961).405-1733507 W W W.CRENG.CO CONTRACTORINFO 690.54 - - OPTIONAL SOLAR LOAD CENTER n ARRAY a,M no C2 SYS . J/B ELEMENT ENERGY LLC. 7470 SOU AVENUE,MZTTITUCK NEW L — PH:(631)779 7993 ■ OUTPUT CONNECTIONI services@e2sys.com INVERTELicence-ME-52689 • NOT ■ • s (MASTER ELECTRICIAN) NEC 690.31(G)(3)&(4),CRC R324.7 Licence-HI-67461 - - - I (SUFFOLK HOME IMPROVEMENT) (UNLESS BUSBAR IS FULLY RATED) L — PHOTOVOLTAIC , • • POWER • - SOURCE Solar Individual Permit Package 705.12(D)(2) LENA DESANTIS EVERY 1 O'ON CONDUIT AND ENCLOSURES 12.150KW Grid Tied Photovoltaic System NOTES. 560 DEER DR, MATTITUCK, NY 11952 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS Rev Description Date SHOWN HEREON. A INITIAL DESIGN 116/2024 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. OPPORTUNITY I LENA DESANTIS B. RED BACKGROUND COLOR WHITE TEXT AND LINE PROJECT# 4679 WORK. DATE DRAWN 1!6/2024 C. AERIAL FONT. DRAWN BY E.R 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN SHEET# PV-6.0 THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BE TITLE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. CAUTION REMOTELY LOCATED DISCONNECT SWITCH AND METER F NE THESE DRAWINGS ARE SUBJECTTO o W y COPYRIGHT PROTECTION BY US LAW. /Yj O REPRODUCTION IN ANY FORM IS MA OQ �0 EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT * _ * RENEWABLES ENGINEERING INC. m C) g y LU 099128 2 Current CTRIGP�' ReneWables ARO�SS1°NPR Engineering STAMPED 01/06/2024 CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SURE RIVERSIDE I 507 -4 ry PHONE: 5S05-1733 WW W.CRENG.CO w CONTRACTOR INFO w PV ARRAY am nk C2SYS' ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK NEW YORK,11952 PH:(631)779 7993 services@e2sys.com s Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 MAIN SERVICE PANEL 7 COMBINER UTILITY METER AC DISCONNECT (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL LENA DESANTIS PANEL IS AC DISCONNECT PER NEC690.17 12.150KW Grid Tied Photovoltaic System 560 DEER DR, MATTITUCK, NY 11952 Rev Description Dale ` A INITIAL DESIGN 1/6/2024 OPPORTUNITY LENADESANTIS PROJECT# 4679 DATE DRAM 1/6/2024 DRAWN BY E.R SHEET# PV-8.1 TITLE PLACARD 1 -10 11 -20 21-30 31 -40 41-50 51 -60 MIC-ROINVERTER CHART 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 - Current- -R.enewabies Engineering CURRENT RENEWABLES 4 ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 UM El WWW.CRENG.CO Ac CONTRACTOR INFO c 5 a rem. ■ CESYS5 1. ENERGY LLC. 6 7470 SOUNDN VENUE,MATTITUCK NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 7 (SUFFOLK HOME IMPROVEMENT Solar Individual Permit Package LENA DESANTIS 12.150KW Grid Tied 8 Photovoltaic System 560 DEER DR, MATTITUCK, NY 11952 Rev Desaiption Date A INITIAL DESIGN 11612024 9 OPPORTUNITY LENA DESANTIS PROJECT# 4679 DATE DRAWN 1J6/2024 DRAWN BY E.R - 10 SHEET# PV-9.0 TITLE MICROINVERTER CHART SAFETY PLAN MARK UP KEY INSTRUCTIONS: C� COMBINER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET. EXPRESSLY FORBIDDEN WITHOUT PRIOR 2.SAFETY PLAN MUST BE MARKED BEFORE JOB AC AC DISCONNECT WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. STARTS AS PART OF THE PRE-PLAN 3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE SP MAIN SERVICE PANEL &MAKE NOTES ON THE JHA SHEET UM UTILITY METER Current IN CASE OF EMERGENCY ® Renewables OP NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC PERMANENT ANCHOR Engineering NAME: F-M CURRENT RENEWABLES TEMPORARYANCHOR ENGINEERING INC. 1760 CHICAGO AVE SUITE ADDRESS: IL INSTALLER LADDER PHONE: 5SI-405-1733DE CA 507 WWW.CRENG.CO SAFETY COACH CONTACT INFORMATION STUB-OUT CONTRACTOR INFO NAME: SKYLIGHT ADDRESS: NO LADDER ACCESS (STEEP GRADE a 0 s ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE 0 OR GROUND LEVEL OBSTRUCTIONS) - SAFETY PLAN AND SIGN INDICATING THAT THEY ARE ❑ CZ 5Y AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR RESTRICTED ACCESS WORKING SAFELY. CONDUIT ELEMENT ENERGY LLC. NAME SIGNATURE 7470 SOUND AVENUE,MATTITUCK GAS GAS SHUT OFF NEW YORK,11952 PH:(631)779 7993 zo WATER SHUT OFF services@e2sys.com OLicence-ME-52689 7 SERVICE DROP (MASTER ELECTRICIAN) Licence-HI-67461 OPOWER LINES (SUFFOLK HOME IMPROVEMENn Solar Individual Permit Package LENA DESANTIS 12.150KW Grid Tied Photovoltaic System 560 DEER DR, MATTITUCK, NY 11952 Rev Desuiption Date A INITIAL DESIGN 1/6/2024 DATE: TIME: OPPORTUNITY LENA DESANTIS PROJECT# 4679 DATE DRAWN 1/6/2024 DRAWN BY E.R SHEET# PV-10.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below,hold a pre-job safety meeting with all personnel,and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. • The safety of the Client and the Public must be maintained at all • The site supervisor shall forecast the weather conditions at the • Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations.Use of onsite restroom is at the clients a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below).If client does not give THESE DRAWINGS ARE SUBJECT TO COPYRIGHT BY secured to the structure.Extension style ladders placed on work zone through the use of barriers and/or signage,as • The site supervisor will utilized a portable wind meter permission,location of suitable restroom facilities with REPRODUCTION IN ANYOFORMtIS LAW uneven,loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. • Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. RENEWABLES ENGINEERING INC. the ladder must extend 36"above the stepping off point. • Pets(including dogs)shall be secured by their owners prior to staging on a roof. Restroom facilities will be circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. Elevated work involving the moving or maneuvering of solar If Offsite,add location name and address: bars locked in the open position;A-frame ladders shall not be • The client should not leave pets,family members;or others in panels shall cease at 25mph(sustained wind)until wind Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure ReneWa{Ules leaned a ainst a structure). Workers. Forecasted weather maximum temp(degrees F): • Contact your Site Supervisor • Additional notes: • Crew leader responsible for communication with the client: Engineering Name: Mobile Equipment • Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment;operators must Yes,No): Heat Related Illness Prevention Phone: CURRENT R G INC. LES maintain a certification on their person for the equipment bein • Employees shall have access to potable drinkin water that is ENGINEERING INC. pg P 9 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13.RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): • All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE:(951)-405-1733 hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: www.cRENG.co • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift.Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor nit hazard to client,personnel or public.Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: �.•�, • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: • A site-specific plan for fall prevention and protection is required Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one E2 SYS9. prior to starting work and must remain onsite at all times until I or more areas with shade at all times. With:Your full name,phone number,office location,brief description - work is complete;a fall rescue plan must be outlined and Crew member(name/title): New employees must be acclimatized.New employees will be of what happen and when. ELEMENT ENERGY LLC. discussed among the crew prior to work start. I I monitored by their Crew Leader(site supervisor)for the first two 7470 SOUND AVENUE,MATTITUCK • First-person-Up(FPU)must install their anchor and connect Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE NEW YORK,11952 before any other task,including installing other anchors.The . Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) Last-Person-Down LPD)must be the onl7993 y (name/title): scheduled breaks during each shift.Employees must take PH:(631) 2s s.co ( y person on a roof Crew member services-ME-5 689 uninstallin fall protection. cool-down breaks in the shade any time they feel the need to do • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Licence-METRICIA • Asbestos-containing(Transite)piping(ACP)-Do not disturb REQUIRED to allow employees any break period they need Define the Hazard: Method/steps to prevent incident: (MASTER ELECTRICIAN) -67461 FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. Licence-HI • Asbestos-containing thermal insulation(ACI)and • Cool Vests are encouraged for all employees at all times during (SUFFOLK HOME IMPROVEMENT) Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. I Solar Individual-Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an LENA DESANTIS electrically safe condition(de-energized)unless approval has If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 12.15OKW Grid Tied • Service drops and overhead electrical hazards will be • If offsite replenish is necessary,where will you go to replenish indentified and protected from contact as neccessa water(location/address): Define the Hazard: Method/steps to prevent incident: Photovoltaic System EQP(name and tile): • Who will replenish the drinking water(name): 560 DEER DR, MATTITUCK, NY 11952 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIAL DESIGN 1l62024 OPPORTUNITY LENADESANTIS PROJECT# 4679 DATE DRAWN 1/6/2024 DRAWN BY E.R SHEET# PV-11.0 TITLE SAFETY PLAN �^ powered by MECHANICAL SPECIFICATION ' !t DUO © Format 74.Oin x4Llinx 1.26in(including frame) (1879 mm x 1C45mm x 32mm) ;,sue rsa pvae..a Weight 4S.5 Front 0.13 In(3.20kg) a... Front Cover 0.131n(3.2mm)thermally pre-stressed glass with Al anti-reflection technology Back Cover Composite film a2rrwe 3 Frame Black anodized aluminum i © Cep 6 x 22 monocrystalline O.ANTUM solar half cells Junction Box 2.09-3.981nx L26-2.36in x0.59-0.711n THESE DRAWINGS ARE SUBJECT TO (53-101mm x 32-60 mm x 15-18mm),IP67,with bypass diodes 'sTP�f0e°^1 COPYRIGHT PROTECTION BY US LAW. Cable 4mmz Solar cable;(+)z49.2in(1250mm),(-)z49.2in(1250mm) s^Oi1�^'� REPRODUCTION IN ANY FORM IS + +^MvW/obrCRLLy Connector StAubli MC4;IP88 � EXPRESSLY FORBIDDEN WITHOUT PRIOR --t." WRITTEN APPROVAL FROM CURRENT o.YllHsmml ICI°'z•las^.m RENEWABLES ENGINEERING INC. . • = , ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405; Current MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC1(POWER TOLERANCE+5 WI-OW) Rt9 Y11 ewabl es Powerst MPF' P_ [WI 385 390 395 400 405 Engineering. E Shon Circuit Current' Ix [A] 1104 1L07 11.10 1114 1117 • Open Circuit Voltage' Vpp IV] 45.19 45.23 45.27 45.30 45.34 Currentet MPP I- [A] 10.59 10.65 10.71 10.77 10.83 CURRENT RENEWABLES 25 -TOP eaARnw Voltage at MPP V [V] 36.36 36.62 36.88 37.13 37.39 ENGINEERING INC. ® Efficiency rl [%J z19.6 z19.9 a201 z20.4 z20.6 1760 CHICAGO AVE SUITE arm 202I MINIMUM PERFORMANCE AT NORMALOPERATING CONDITIONS,NMOT J-13,RIVERSIDE CA 92507 2 Warranty O CELLS Poweret MPP P_ IWI 288.8 2926 298.3 3001 303.8 PWWW.CRENG.001733 eomnaoana..m rcld S-,.,y E Short Circuit Current 1. [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Vpp IVI 42.62 42.65 4Z69 42.72 4276 CONTRACTOR INFO �rI BREAKING TH E 20%EFFICIENCY BARRIER CurrentetMPP I_ [A] 8.35 B.41 SAS 8.51 8.57 �nl II I Q.ANTUM DUO Z Technology with zero gap cell layout Voltage at MPP V_ M 34.59 34.81 35.03 35.25 35.46 JIWJLL boosts module efficiency up to 20.9%. 'Measurement tolerances P,cr•t3%;Igo:Vwt5%at STD:1000W/W.25226C,AM L5 emord'mg to IEC 6091343•2600W/m2,NMOT,spectrum AM 1.5 I O CELLS PERFORMANCE WARRANTY _ _ PERFORMANCE AT LOW IRRADIANCE I THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY g --T-----r----------n------ t "' o� At least 98%of nominal power during Q CELLS is the first solar module manufacturer to pass the most 0omprehen- 9_ °�"m """` first year.Thereafter max 0.5% r ____ degradation per year.At least 93.5% _ I Q slue quality programme in the industry:The new'Quslity Controlled PV'of E -" """"""' P g C P. S9, - �t><r _ W of nominal power up to SO years.At 5 ' dent"cerfificatloninstittite-TUV'{ZheinlBnd. +�� least 86%otnominal power up to 25 Yeara. a --------- IN IN OVATIVE ALL-WEATH ER TECHNOLOGY B All data within measurement tolerenc- a ELEMENT ENERGY LLC. B es.Full warranties in accordance wth ¢ 'D �; Optimal yields,whatever the weather with excellent the wanemytermsol the QCELLS ; 0 7470 SOUND AVENUE,MATTITUCK low-light and temperature behavior" 8 „ sales orgenisahon of your respective R N E W YO R K,11952 country. �ry� ro � s .ewes Typical module performance under I=Imidlance conditions In PH:(631)779 7993 ENDURING HIGH PERFORMANCE comparLsmfto STCconditiom(25°C,1000W/m2I Long-term yield security with Anti LID Technology,Anti PID services@e2sys.com 9 Y Y 9Y. 'TEMPERATURE COEFFICIENTS Technology',Hot-Spot Protect and Traceable QualityTra.QTM. o Licence-ME-52689 Temperature Coefficient of lap a [%/KJ +0.04 Temperature CoefflcientofV_ III [%/KI -0.27 (MASTER ELECTRICIAN) Temperature Coefficient of P_ y [%/KJ -0.34 Nominal Module Operating Temperature NMOT rF] 109x5.4(43t3"C) Licence-HI-67461 EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN (SUFFOLK HOME IMPROVEMENT) high snow(5400 Pa)and wind loads(4000Pa). Maximum System Voltage Vm Iv] 1000(iEC)/1000(UL) PV module classification Class ll d Solar Individual Permit Package c� Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 1 A RELIABLE INVESTMENT Max.Des ign Load,Push/PUIP -40`Fu to tlbs/ft2] 75(360OPa)/55(266OPs) Permitted Module Temperature p C Q �„J Inclusive25-year product warranty and25-year z on Continuous Duty (-40'Cupto+85'C) ® LENA DESANTIS l [( linear performance warranty'. M..Test Load,Push/Pull [lbs/ft9 113(540oPe)/84(4000Ps) a 'See Installation Manual 'APT test conditions-ding to IEC/TS 62804.12015,method A(-1500V,96h) 9 12.150KW Grid Tied 2 See date sheet on rear for fuller information. QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION Photovoltaic System UL 61730,CE" pisri4 Ia °T $, ouelry�uedPv-T0VRwr1am. edv F Nb�I ° 3 560 DEER DR, - - IEC 81215,2016,IEC 81730:2018, All. THE IDEAL SOLUTION FOR• uS.PeCW.t sse3z15(sderpeimi. CE ''rovr�a Horizontal 78.4In 43.3In 48.Oin 18581bs 24 24 32MATTITUCK, NY 11952 • "ocPv carwceuospeedng. �,,,,,,us ♦♦ � packaging 1940mm SSOOmm 1220mm, 751kg pellets pellets modules S! Rooftop arrays on wenm m rr;vw ra resldentiel buildings Rev Description Date Note:Installation instructions must be followed.See the instellaton and operating manual oroontact our technIcai service department for further information on approved'retaliation and use of A INITIAL DESIGN 116/2024 this product OCELLS 400Hanwha0DELLBAm rive,lna Engineered in Germany 4005pectrum Center Drlve,Sude1400,Irvine.CA92618,USA ITEL+1 949 748 59 961 EMAILinquiry@us.q•celiscomlWEBwww.q•cells.us OPPORTUNITY LENADESANTIS PROJECT# 4679 DATE DRAWN 116/2024 DRAWN BY E.R \ SHEET# PV-12.0 TITLE MODULE SPEC EN PHASE. 1�11 IQ8 and IQ8+ Microinverters -- - ---- Commonly used module pairings' - - IN : : 235-350 �__ : 235-440 To meet compatibility,PV modules must be within maximum Input DC voltage and maximum module I - Module compatibility _ r c listed below. o Module compatibilitycan be checked at httos•//enobase com/Instalters/mlcroinverters/calculator • MPPTvoltagerange : V' - - - ~.27-37 :.27-45 Operating range V l 16-48 - " - 16-58 - - _ THESE DRAWINGS ARE SUBJECT TO ------ --- ----- --- --- -- -+- - - - - - _ _-- - -. COPYRIGHT PROTECTION BY US LAW. } _ } Minimum/Maxlmumstartvo_Ita • :V - --_ 22/48 - - : 22/58- - - - _ _ _ 9 - - - - _ - _ REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR 1 ,i Maximum input DC vohage ' V 50 60{ - - � WRITTEN APPROVAL FROM CURRENT j ,-Maximum coritinuous•inputDCcurrent - - A - - _ 70 - - - 12 RENEWABLES ENGINEERING INC. f Maximum input DC short-circuit current A I - - -- - - 25 I I _ a ::Maximum module I., , - A - - - - - - - 20: - - - - - - Overvoltage class DC port - Current --- - ._ - -- - - ' _- - -- - -- _-- - - -- - : , .---_--- -- - -" - --- $�py�I®gad!: ®t -0C port backfeed current mA - - _ - _ --- "----�_' �6ir814a�V 6'7r 'oora7 PV array configuration F- Engineering 1.l ungrounded array;no additional DC side protection required;AC side protection requires maximum 20 A per branch circuit[ OUTPUT DATA MCI. UNITS 108-602US IOSPLUS 72.2-US CURRENT RENEWABLES Peak output power _ VA 245 - 300 _ j ENGINEERING INC. 1760 CHICAGO AVE SUITE Maximum continuous output power- # VA i 240 1 290_ - J-13,RIVERSIDE CA 92507 -- -- _ -- - - - ----- Nominal grid voltage(L=L) - _ V : - : - : -24Osplit-phase(L-L),18O`, - - - - - PHONE:(951)-005-1733 - WNW.CRENG.CO Q 8 and I Q 8 Microinverters EasytQinstall : Minimum and Maximum grid voltage' i V I 211-264 I--_ - CONTRACTOR INFO m I Lightweightand Compact with plug- - Maximu continuous output current- A 1.0: : : - - 121 Our newest 108 Microinverters are the industry's first microgr(d-forming,software-defined and-play connectors. Hz' 60 Powerline commum microinverters with split-phase power conversion capability to convert DC power to AC I - - . ic = - Nominal frequency-�- - _ i ation(PLC) !♦\illy power efficiently.The brain of the semiconductor-based microirnerter is our proprietary ;: Extended frequency 47 sa range Hz _ : application-specific integrated circuit(ASIC),which enables the microlnverter to operate in _between components : ' - - - circuit fault current over grid-tied oroff-grid modes.This chip is built using advanced 55-nm technology with high-speed : - Faster installationwith simple two-wire : 1 ac short digital logic and has superfast response times to changing loads and grid events,alleviating cablin +�wse _ three cycles constraints on battery sizing for home energy systems. t - - : : - - - - Maxirnumunitsper20A-L-L)branch : : __ - - - - '16- : _ - _ _ - :13 : - ' - - circuit' - _ - - - - EESYS'. i s -High productivityandreliab8it9 - - - =_----=--- ___ ----- ----- - - - ------ j - Total harmonic distortion ~� % I <5 •'Produce power even when the grid is - i--- - — down• : : Overvoltage class ACport, III ELEMENT ENERGY LLC. ~- 7470 SOUND AVENUE,MATTITUCK :• more than one million cumulative hours- : AC port backfeed current mA l30 "" .. of testing Power-factor setting : - - _ - - -:1.0 - _ ---_ P 7993 NEW YORK,11952 'Class If-double-insulated enclosure -=--=--'-�--" "-- - -" — -- H:(631)779 Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging i — services@0e2sys.com Part of the Enphase Energy System, I08 Series Microinverters redefine Optimized for the latest high=powered Licence-ME-52689 108 Series Microinverters Integrate with the reliability standards with more than one PV modules•- Peak efficiency %" 97.7 (MASTER ELECTRICIAN) 10 Battery,10 Gateway,and the million cumulative hours of power-on : : _ : : CEC weighted efficiency } % { 97 Licence-HI-67461 Enphase App monitoring and analysis testing,enabling an industry-leading Micro rid-formin : : " software. limited warranty of up to25years. g g : Nighttime ; mWr 2a 25 (SUFFOLK HOME IMPROVEMENT) Compliant with the latest advanced " i grid support'" : - : : _ - Solar Individual Permit Package --- r_ ��_� - -� - -----_.---=-------=- --'----� .—.�__�. Arglifent temperatureange _ 4O'Cto60°C(4&Fto14&F) •'Remote automatic updates latest gridregUirements' - - Relative humidity range 4%to 100%(condensing) LENA DESANTI.S _- '. � � MC4- - - - - - : - • Configurable to support 8 wide range: : DC connector-type` -- _ - '- : of grid profiles 212mm(8.3 In)<175 min(6.9 in)x302mmn.2in) - 12.150KW Grid Tied Dimensions(H•W•D) Meet CA Rule 21(UL 1741-SA)and IEEE' - toe kg(2.3a Ibs) PhOtOVOIt81C System Connect PV modules quickly and easily 108 Series Microinverters are UL Listed d Weight : y to 108 Series Microinverters using the as PV rapid shutdown equipment and 1547:2018(UL 1741-SB 3',Ed.): included O-DCC-2 adapter cable with conform with various regulations,when cooling va_ - 560 DEER DR, I Naturaloon ction no fans plug-and-play MC4 connectors. installed according to the manufacturers i" NOTE: - Approved for wet locations . Yes _ Instructions. . • MATTITUCK, NY 11952 108 Microinvehers cannot tie mixed with.- Pollution PD3 j - Pollution degree f .pmvlcus generations of Enphase mlcroinverters !" : .(la7series,106serles;andmon)inthesaine Enclosure- - - - .' - Class ll double-insulated,corrosion-resistant polymeric enclosure _ Rev Description Date _-system - - - - - - - - —_ - A INITIAL DESIGN 1/6/2024 : IOGatewaylsrequlredtochangethedetautt - Environmental category/UV exposure rating NEMA Type 6/Outdoor *Meats UL 1741 only when Installed with 10 System Controller 2 .grid profile at the time of Installation to meet - '•I08 and 108+support split-phase,240 V Installations only. 4 � - : brat AuthorityHa IngJuris_dlctlon(AHJ)- - requirements. _ - _ OPPORTUNITY LENADESANTIS 02023 Enphase Energy.All rights reserved.Enphas&the a and CC logos,IQ and certain other merits listed at _ 3 U)Naanlorcad DC/Acmtia. `` ' -_.._. _. � (1)Nominalwhagerangooan beeaendad barsad rmminallfraquhad by tho�nuar. PROJECT# 4679 Mtos://enohms m/imdemark-usane-ouidennes are trademarks of Emebase Energy,Inc.in the US and other countries.Data subject to change. I085P-12A-DSH-00207-2A-EN-US-2023-10-13 (3)umrca mayvary.eMorto]=at mulm-nis1.daflno the numtmre Merolnwrtera wbanchIn Your ar- 1085P-12A-D5H-00207-20-EN-US-2023-10-13 DATE DRAWN 1/6/2024 DRAWN BY E.R SHEET# PV-12.1 TITLE MICROINVERTER SPEC IQ Combiner 4/4C Data Sheet Enphase Networking MODEL NUMBER IQ Combiner 4 IQ Combiner4with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12-20±0.5%) 1 i X-IQ-AM1-240.4 and consumption monitor;ng(±2.5%).Includes a silver solar shield to match the IQ Battery and IQ System Connoller2 and to X2-lQ-AM7-240-4(IEEE15472018) deflect heat. IQ Combiner 4C — - IQ Combiner 4C with IQ Gateway primed circuit board for integrated revenue grade PV production metering(ANSI C1220±0.5%) IQ Combiner 4/4C The IQ Combiner 4/4C with IQ Gateway and X2-1 AM7-240-4C industrial-grade cellmtdemf±syste Includes 0miMobcrConnectcelvailabeinthelular modem S,Cana a,MexiOb-SPertoRic,and the y X2-IQ-AM1-240-4C industrial-grade cell modem for systems up to60micrainverters.(AvailableintheUS,Canada,Mexico,PuertoRico,andthe US Virgin Islands,where there is adequate cellular service in the installation area.)Includes a silver solar shield to match the integrated LTE-M1 cell modem(included IQ Battery and IQ System Controller and to deflect heat THESE DRAWINGS ARE SUBJECT TO ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) COPYRIGHT PROTECTION LAW. Only with IQ Combiner 4C)consolidates ACCESSORIES IN ANY FORM IS IS I Supported microinverteis IQ6,IQ7,and IQ&(Do not mix IQ6/7 Microinverters with 108) EXPRESSLY FORBIDDEN WITHOUT PRIOR interconnection equipment into a single WRITTEN APPROVAL FROM CURRENT Communications Kit RENEWABLES ENGINEERING INC. - ---- — - enclosure. It streamlines IQ Microinverters and COMMS-CELLMODEM-Ml-06 Includes COMMS-KIT-01 and CELLMODEM-M7-O6-SP-05 with 5-year Sprint data plan CELLMODEM-MI-06-SP-OS -4G based LTE-M7 cellular modem with 5-year Sprint data plan storage Installations by providing a consistent, -CELLMODEM-M7-06•AT-05 -4G based LTE-MI cellular modem with 5-year AT&T data plan, ---------------- ------ —----------- ---- —----- ------ ---------------------- ----- -- Circuit Breakers _ Supports Eaton BR210,BR215,BR220,BR230,8R240,BR250,and BR260 circuit breakers. 'C urre^} n - aENPHASg ( BRK-IOA-2-240V Circuit breaker,2 pole,1OA,Eaton BR210 - 1 I L pre-wired solution for residential applications. BRK-15A2-240V Circuit breaker,2 pole,iSA,Eaton BR215 ReneWableS I BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 It offers up to four 2-pole input circuits andEngineering , a I BRK-15A-2P-240V-B Circuit breaker, - E�glneGring ' Eaton BR series bulbar assembly. �I 8RK-20A-2P-240V-8 ^-i—` Circuit breaker,2 pole,20A,Eaton BR220B with hold downkit support - - --- v -� _ XA-SOLARSHIELD-ES Replacement solar shield for IQ Co mbiner 4/4C _ yrXA-PLUG-120-3 - —� Accessory receptacle for Power Line CanierinlQCombiner4/4C(requiredforEPLC-01) —J _M' CURRENT RENEWABLES ENGINEERING INC- - i X-I0-NA-HD-125A - -_� Hold-down kit for Eaton circuit breaker with screws - - - -- -- ---- 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 _ i �C—assumption monrtonng C7 - A pair of 200A split core current transformers _ _ i PHONE:(951)405-1733 $ _ - Smart I(cT-200-SPLIT/CT-200-CLAMP) WWW.CRENG.CO ELECTRICAL SPECIFICATIONS V • CONTRACTORINFO Includes IQ Gateway for communication and control 'R Continuous duty • Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-O5),included only with Systemvoltage 120/240VAC,60 Hz F tl EatonR series busbar rating 125A IQ Combiner 4C65A --1 I Max.comintaus current rating Includes solar shield to match Enphase IQ Battery e�_ _ O F� aesthetics and deflect heat �� —a9(�P�from�/ tee) 64A —_ ^- y -- -err/ • Supports Wi-Fi,Ethernet,or cellular connectivity Max.fuse/circuit rating(output) ^—_90A _-- — -`-i �_ S ■ S0 Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included),-- , !, • Provides production metering and consumption Max.total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included S• monitoring (IQQGGatevraybreaker 10Aor15A rating GE/Siemens/Eatonincluded _ _ _ _ ---1 ELEMENT ENERGY LLC. 2' Production metering CT 200A solid core pre-installed and Wired toIQGateway Y - 7470 SOUND AVENUE,MATTITUCK Simple MECHANICAL DATA NEW YORK,11952 • a' #Dimensions(WxHxD) 37.5 cm x 49.5 cm x 16.8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mounting brackets. I P H.(631)779 7993 XIQ-AM1240-AN Mounts on single stud with centered brackets L�� �_�__��____� --v____ .___--__�__ -__ _-__-�__w______i services@e2sys.com ( weight 7.5kg(16.5lbs) Licence-ME-52689 - X2-1¢AMt 240-4C(IEEE 1547.2018) Supports bottom,back and side conduit entry -__--y _ _ _ _- _ _--_ _ fir. h • Allows up to four 2-pole branch circuits for240VAC' {Ambient temperature range ' � 40^Cto+46^c(-aD-FtonsAF) — (MASTER ELECTRICIAN) rr; i r L-_ "_._` -- ------------_ --`-•—'----------_--" -- -plug-in breakers(not included) Cooling �— ~Natural convection,plus heat shield Licence-HI-67461 - ------------- - - - --- — - --- --- - -- - -- - • 80A total PV or storage branch circuits �Enclosure environmental racing �- i Outdoor,NRTL-certified,NEMAtype 3R,polycarbonate construction � (SUFFOLK HOME IMPROVEMENT) 6 VAresizes 20Ato50A breaker inputs:14to4 AWG copper conductors -- Solar Individual Permit Package ;- •60A breaker branch input 4 to 1/0 AWG copper conductors Reliable a •Main lug combined output:10 to 2/0 AWG copper conductors •Neutral and ground:14 to 1/0 copper conductors LENA DESANTIS Durable NRTL-certified NEMA type 3R enclosure --_- •Always follow local code requirements for conductor sizing. -,- - -�- -_ - -- • Five-year limited warranty Altitude Up to 3,0 00 meters(9,642 feet) - —� —� — 12.150KW Grid Tied Two years labor reimbursement program coverage INTERNET CONNECTION OPTIONS t included for both the IQ CombinerSKU's Integrated WI-Fi IEEE802.11b/g/n Photovoltaic System fi- - ---- - X I¢AM1240-4 X2IIQtAM1-IQ 4 and X2-IQ-AM7-240 4C comply with Cellular CELLMODEM-Ml-06-SP-05,CELLMODEM•Ml-06-AT-05(4G based LTE•M1 cellular modem).Note that an Mobile Connect 560 DEER DR, X21¢AMt-240,4(IEEE 1547:2018) p y - --- cellular modem is required for all Enphase Energy System installations. IEEE 1547:2018(UL 1741-SB,3'd Ed.) Ethernet Optional,IEEE 80 (or23,CatSE Cat6)UTP Ether clud net cable(not included) MATTITUCK, NY 11952 COMPLIANCE Rev Description Date I Compliance,IQ Combiner CA Rule 21(UL 1741-SA) A INITIAL DESIGN 1/6/2024 e IEEE 1547:2018-UL 1741-SO,3"Ed.(X2-IQ-AM7-240-4 and X2-IQ-AM1.240.4C) CAN/CSA C22.2 No.107.1,Title 47 CFR,Part 15,Class B,ICES 003 -Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering:accuracy class 2.5 ENPI-IASE. ----� ----- --_- - --� -_-_____- -r- ----,�- -- OPPORTUNITY LENADESANTIS To learn more about Enphase offerings,visit enphase.com Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.67010-1 IQ-C-4-4C-DS-0103-EN-US-12-29-2022 C12022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of PROJECT# 4579 Enphase Energy,Inc.Data subject to change. 1Q-C-4-4C-DS-0103-EN-US-12-29-2022 DATE DRAWN 1/6/2024 DRAWN BY E.R SHEET# PV-122 TITLE COMBINER SPEC Zl�IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes.Each size supports specific Solar is Not Always Sunny design loads,while minimizing material costs.Depending on your location,there is an XR Rail to match. Over their lifetime,solar panels experience countless THESE DRAWINGS ARE SUBJECT TO ---^`�"i �- extreme weather events.Not just the worst storms in years, COPYRIGHT PROTECTION BY US LAW. ir' . � ,z REPRODUCTION IN ANY FORM IS but the worst storms in 40 years.High winds capable of _ _ r_ ��, EXPRESSLY FORBIDDEN WITHOUT PRIOR r ripping panels from a roof,and snowfalls weighing - ""-"� WRITTEN APPROVAL FROM CURRENT enough to buckle a panel frame. _ 1 ham_, _ - RENEWABLES ENGINEERING INC. XR Rails are the structural backbone preventing '�� xR,o xR100 -,. xR1000 Current these results.They resist uplift,protect against buckling and safe) and efficiently Renewables 9 9 Y y ;rr XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among transfer loads into the building structure. ;;={� rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle es Engineering Their superior spanning capabilityf 4 ~` no snow.It achieves 6 foot spans,while wind and snow conditions,white also extreme climates and spans 12 feet or requires fewer roof attachments, r _f-a� remaining light and economical. maximizing spans up to 8 feet more for commercial applications. f .�` CURRENT RENEWABLES reducing the number of roof =: , 6'spanning capability e'spanning capability 12'spanning capability ENGINEERING INC. g -� y Moderate load capability Heavy toad capability ClearExtremen load capability 1760 CHICAGO AVE SUITE penetrations and the amount - '"ti '` _ r 1 tit "_:'� Clear anodized finish Clear&black anodized finish • Clear anodized finish PHONE: RIVERSIDE-1 92507 of installation time. -t' �: `. .` �, Internal splices available Internal splices available Internal splices available PHONE:(951)405 1733 �` I�. WWW.CRENG.CO CONTRACTOR INFO Rail Selection The following table was prepared in compliance with applicable engineering codes and standards.Values are based on the following criteria:ASCE 7-10,Roof Zone 1,Exposure B,Roof Slope of 7 to 27 degrees and Mean t }I Building Height of 30 ft.Visit IronRidge.com for detailed span tables and certifications. 00 _ fir: Ji E2SYS . � ELEMENT ENERGY LLC. II 7470 SOUND AVENUE,MATTITUCK Force-Stabilizing Curve 100 i NEW YORK,11952 Sloped roofs generate both vertical and lateral 120 . . . { PH:(631)779 7993 F forces on mounting rails which can cause them None —1 services@e2sys.com to bend and twist The curved shape of XR Rails 140 XR1'0 Licence-ME XR100 XR1000 a4 e;. •. __Ls special -dess�ned to increase siren _in both ! directions while resisting the twisting.This unique l (MASTER ELECTRICIAN feature ensures greater security during extreme 160 Licence-HI-67461 weather and a longer system lifetime. 100 (SU FFO LK HOME IMPROVEMENT) I 120-) Solar Individual Permit Package d 10-20 140 LENA DESANTIS 160 160 12.150KW Grid Tied 30 Photovoltaic System 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials DEER DR, 100 MATTITITUCK, NY 11952 XR Rails are IronRidge offers All XR Rails are made of marine-grade *04v� 40 compatible with a range of tilt leg aluminum alloy,then protected with an 160 Rev Description Date FlashFoot and �■ options for flat anodized finish.Anodizing prevents surface A INITIAL DESIGN 1/6/2024 other pitched roof ■�■ roof mounting and structural corrosion,while also providing 50-70 160 attachments. applications. a more attractive appearance. 80-90 160 --- .- - _ - -- _ _ - -- _- - - - - - -- - — - - -- - - --- - .----'—_--_-- OPPORTUNITY LENADESANTIS PROJECT# 4679 DATE DRAWN 1/6/2024 V. 0 8 00 DRAWN BY E.R SHEET# PV-12.3 TITLE RAIL SPEC PN# BOX CITY 17664 5.25"Bolts(25) 15894SS SS L-Foot for Low Profile QB 1(25) . 17666 Bolts+3"Microflashing®(25eo.J TPO� f Bolts+3"Miaofloshing® .t •-%.� „r.-' �T.:_;..,;= 17667S5 - +SS L-Foot+Nuts 25ea. THESE COPYDRARIGHT PROTINGSECTION ARE SUBJECT A y r Asphalt Shingle TPO Roofing Side Mount ( ) COPYRIGHT PROTECTION R IS LAW. REPRODUCTION IN ANY FORM IS First&only Microflashing®in the industry. EXPRESSLY FORBIDDEN WITHOUT PRIOR Stainless Steel L-Foot. WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Now tested&approved for TPO roofs. ULCeriliffed. 3"Microflashing© Low Profile .� Patent#844 Current Renewables L PN# BOX CITY r : `��- -�- Engineering 17664 5.25"Bolts(25) �i�j" 9 17720 Bolts+4'Microflashin ®(25ea. ) CURRENT RENEWABLES y �f7a 4"R'O ti V y, rr w _ - - ENGINEERING INC.Bolts+4"Miaoffashin O 17721SS 1760 CHICAGO AVE SUI TE7TPa +SSL-Foof+Nuts(20ea-) PHONE: RIVERSIDE-1 92507 PHONE: ENG.05-1733 First&only Microflashing©in the industry. www.cRENG.co _ "2 t•�' ,�yv Asphalt Shingle TPO Roofing Side Mount P_ g g Stainless Steel L-Foot. CONTRACTOR INFO `aa 4"Microflashing©provides more coverage. 9_,c Now tested&approved forTPO roofs. UL Certified. 4"Microflashing© Low Pmfile Fatent#8448407— a,a i ® • - - - -- BOX CITY, SU. �. .: E2 ;r �'���•^ � 5 t/n"Bolts(50) +3"Microfloshing(D(50) s T. 17667DF + ini aching©+SS L-oot 50 - ELEMENT ENERGY LLC. +Nuts(50) 7470 SOUND AVENUE,MATTITUCK NEW YORK,11952 QuickBOLT has the most innovative line of Asphalt Shingle Roof i ( ~T = I Low Profile QB1 with Microflashing®and PH:(631)779 7993 0 Mounts in the industry. ; _ ~~ >` 2 Miniflashing©. services@e2sys.com Asphalt Shingle TPO Roofing Side Mount Licence-ME-52689 Our QuickBOLT with Microflashing®is the future of Asphalt ( ' M No sealant requiredl (MASTER ELECTRICIAN) Shingle Roof solar mounting.Use the QuickBOLT to save time and 03' Licence-HI-67461 money by installing faster,eliminating the need for bulky aluminum + r �� H " '.___J` (SUFFOLK HOME IMPROVEMENT) flashing,and completing more residential jobs.The installers' • 3•Mi`r°Roshiag° 1°w P`°rite Solar Individual Permit Package liability is also reduced,as Microflashing®can be installed directly — 'Paie�iss�4s4>17 —---- over the shingles and does not require the removal of any nails. LENA DESANTIS The QuickBOLT is now tested and approved for TPO roofs. _ PN# BOX QTY ' s1;` y. t 17894 Black Split To L (25ea.) " ��•'.-�,•- -_�' •: p . p Foof- 12.150KW Grid Tied 17821 5.25".Bolts+3"Microflashingo0 Photovoltaic System AVAILABLE ONLINE: r` '' t- +Blk S pill Top L-Foot+Nuts(25ea.) _�TPOR: f 560 DEER DR, 'ae D First&only Microflashing®in the industry. Stainless Steel L-Foot. MATTITUCK, NY 11952 '6-•^ - ¢'' Asphalt Shingle TPO Roofing Side Mount Split Top L-Foot for compatibility with saddle Rev Description Date 1 attachments. Now tested&approved for TPO roofs. A INITIAL DESIGN 11612024 ULCertified. $ ecs&Test Racking Installation 13 c 3"MicrofiashingO Low Profile ULCertificbtion P 9 Videos _ OPPORTUNITY LENA DESANTIS Results Compatibility Instructions 'fatent#8448407- PROJECT# 4679 DATE DRAWN 1/6/2024 DRAWN BY ER SHEET# PV-12.4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. - 28357 Industrial Blvd. ��� ��®��'��� Hayward,CA 94545 Hayward,CA 94545 1-800-227-9523 ZA&IRONRIDGE 1-800-227-9523 IronRidge.com IronMdge.com Attn:Corey Geiger,COO,IronRidge Inc. Date:September 70i,2021 The parameters and adjustments allowed in the span tables are defined as the following: Re Structural Certification and Span Tables for the IronRid a Flush Mount System 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5-1. THESE DRAWINGS ARE SUBJECT TO • P g Ys COPYRIGHT PROTECTION BY US LAW. 2. Wind speed shall conform to ASCE 7-16 Fig.26.5-1 B(for Risk Category II)and applicable state&local REPRODUCTION IN ANY FORM IS This letter addresses the structural performance and code compliance of IronRid e's Flush Mount System. The count /cit amendments to the IBC. No special Wind topographic features are included and both topographic EXPRESSLY FORBIDDEN WITHOUT PRIOR P P 9 Ys Y Y PWRITTENAPPROVAL FROM CURRENT contents of the letter shall be read in its entirety before applying to any project design.The Flush Mount System is a coefficient(Ka)and Wind ground elevation factor(Ke)are taken as 1.0. RENEWABLES ENGINEERING INC. proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape 3. Snow load used in the span tables is the ground snow and shall conform to ASCE 7-16 Fig.7.2-1 and orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails applicable state&local county/city amendments to the IBC.If the local jurisdiction specified snow load is in the and secured to the rails With IronRidge mounting clamps.The XR Rails are side mounted to a selected roof format of a flat roof snow,it shall first be converted to a ground snowfollowing the local building code/ Current attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables.No special snow conditions are considered Renewables that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding,retention,or ponding snow.No rain-on-snow surcharge load is Engineering components are shown in Exhibit EX-0015. considered.The span tables do not apply to buildings which are intentionally kept below freezing,kept just above freezing,or unheated. CURRENT RENEWABLES The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: ENGINEERING INC. 1760 CHICAGO AVE SUITE listed below,for the load conditions and configurations tabulated in the attached span tables_ J-13,RIVERSIDE CA 92507 (a)For ground snow no greater than 42psf:Ss<2.Og for Site Class A,B,C,&D. PHONE:(951)-405-1733 ASCE/SE17-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:Sa<1.Og for Site Class A,B,C,&D. W W W.CRENG.CO 2018 Intemational Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:Sa s 1.5g for Site Class A,B,C,&D. CONTRACTOR INFO 2020 Building Code of New York State(BCNYS-2020,Published in November 2019) 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-2I and are organized into three groups in Report uminuSEAO (Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients(GCp).Roof zones comprising each group along with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. NO The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point,shall the respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8"to 45'.The tabulated spans are applicable when the &configuration condition from the span tables,or 36". following conditions are met: 7. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over ELEMENT ENERGY LLC. a minimum of three spans. 7470 SOUND AVENUE,MATrITUCK 1. Span is the distance between two adjacent roof attachment points(measured at the center of the NEW YORK,11952 attachment fastener). 8. No splices are allowed in the rail cantilever.For each XR splice type install per the following requirements: PH:(631)779 7993 a) XR Bonded Splice cannot be installed in the center 113 of interior spans,or the outer 2/3 of end spans. services@e2sys.com 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system).Spans are calculated b) BOSS Splice can be installed at any location within a span. Licence-ME-52689 based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems. (MASTER ELECTRICIAN) 9. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded.If Licence-HI-67461 3. The underlying roof slope,measured between the roof surface and horizontal plane,is 8e to 45e. such conditions are encountered contact support@ironridge.com. (SUFFOLK HOME IMPROVEMEN1) Solar Individual Permit Package 4. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from grade,does not exceed 30 feet. LENA DESANTIS 5. A clearance from the underside of the array to the roof surface of 2"minimum shall be provided and the 12.15OKW Grid Tied height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not Photovoltaic System exceed 10". 560 DEER DR, 6_ Module length and area shall not exceed the maximum values listed on the respective span tables. MATTITUCK, NY 11952 Rev Description Date 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush A INITIAL DESIGN 11612024 Mount Installation Manual and other applicable standards for the general roof construction practice. OPPORTUNITY LENA DESANTIS O 2021 IronRidge,Inc. NY Flush Mount System Certification Letter-1 O 2021 IronRidge,Inc. NY Flush Mount System Certification Letter-2 PROJECT# 4679 DATE DRAWN 1/6/2024 DRAWN BY E.R SHEET# PV-12.5 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd. AAL IRONRIDGE Hayward,CAsa545 Z��IRONRIDGE Hayward,co 94545 Hayward,CA 1-800-227-9523 IronRidge.com IronRidge.Com 10. Systems using CAMO module clamps shall be installed with the following guidance: a) For single module installations(orphan modules)using modules with a length greater than 67.5",CAMO The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no clamps shall not be installed in regions that experience ground snow loads thof great and greater.Such consideration of the structural adequacy of the chosen roof attachments,PV modules,or the underlying roof supporting THESE DRAWINGS ARE SUBJECT TO scenarios are shown b asterisks i the h livable span tables. members.It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the COPYRIGHT PROTECTION BY US LAW. Y pp P REPRODUCTION IN ANY FORM IS b) CAMO will function within a module°s design load ratings.Be sure the specific module being used withaforementioned system components in regards to the applied or resultant loads of any chosen array configuration. EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN CAMO meets the dimensional requirements shown in the figure below and that the module selected is ENEW BL APPROVAL ENT ES E IN C. C. suitable for the environmental conditions of a particular project. OF xr:Sincerely, 2 0 21 ®9 0 7 _ ' �ti>;.xu � -- - -_ - • • j Aod1teeCIdz/Ce9s ; * ._' '° Current Reftewables --- Engineerin-g 9 CURRENT RENEWABLES Fro"compoftatl-� — ENGINEERING INC.; X=1.2-2.2rtan 0 CHICAGO AVE SUITE i i Y=15—40 nun J7113,RIVERSIDE A 92507 Gang Xuan,PE PHONE:(951)-405-1733 Senior Structural Engineer WWW.CRENG.CO T� X �—T CONTRACTOR INFO Figure 1_CAMO Module Frame Dimensional Requirements Span values for Exposed and Edge module conditions,as defined below,are included in the attached span tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge .+..�. modules shall be the lesser of the following two:(1)The span value for the Exposed or Edge module condition; (2)The span value determined by site wind speed and ground snow load.Additionally,irrespective of the lesser 2 SYS9 span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage limitation detailed in note 9 of page 2 shall apply to the respective condition. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATiITUCK 1. Exposed Module conditions: NEW YORK,11952 PH:(631)779 7993 A module is defined as Exposed(per Section 29AA of ASCE 7-16)if the distance from any of its free services@e2sys.com edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge,rake,or Licence-ME-52689 hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from its free edge to any (MASTER ELECTRICIAN) Licence-HI-67461 other adjacent array or panel is greater than 4 feet. (SUFFOLK HOME IMPROVEMENT) The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed Solar Individual Permit Package Modules. LENA DESANTIS 2. Edge Module conditions: 12.150KW Grid Tied A module is defined as an Edge Module when its distance from any side of the module to its facing Photovoltaic System perimeter roof edge(such as eave,ridge,rake,or hip)is less than 2 times the height of the array(2h2) 560 where h2 is measured from the roof surface to the top surface of the module. DEER DR, MATTITITUCK, NY 11952 The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules_ Additionally,if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered Rev Description Dale A INITIAL DESIGN 1/6/2024 for this span adjustment. OPPORTUNITY LENADESANTIS ©2021 IronRidge,Inc. NY Flush Mount System Certification Letter-3 O 2021 IronRidge,Inc. NY Flush Mount System Certification Letter-4 PROJECT# 4679 DATE DRAWN 1/6/2024 DRAWN BY E.R SHEET# PV-12.6 TITLE CERTIFICATION