Loading...
HomeMy WebLinkAbout48206-Z �O�OguFFOL�'C'pGy _ Town of Southold 7/13/2024 P.O.Box 1179 W X. 53095 Main Rd Southold New York 11971 CERTIFICATE OF OCCUPANCY No: 45351 Date: . 7/13/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 300 Harbor Rd, Orient SCTM#: 473889 Sec/Block/Lot: 27.4-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/11/2022 pursuant to which Building Permit No. 48206 dated 8/25/2022 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Allecia Family Trust of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48206 2/22/2024 PLUMBERS CERTIFICATION DATED Aut oriz ignature S��FocK� TOWN OF SOUTHOLD BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48206 Date: 8/25/2022 Permission is hereby granted to: Allecia,.Sandra 300 Harbor Rd Orient, NY 11957 To: install roof-mounted solar panels to existing single-family dwelling as applied for with flood permit. At premises located at: 300 Harbor Rd SCTM #473889 Sec/Block/Lot# 27.4-5 Pursuant to application dated 7/13/2022 and approved by the Building Inspector. To expire on 2124/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Flood Permit $100.00 Total: $300.00 Building Inspector 0v SO!/l�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.deviina-town.southold.nv.us Southold,NY 11971-0959 Q�yOUNT1,�� - BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Sandra Allecia Address: 300 Harbor Rd city,Orient st: NY zip: 11957 Building Permit#: 48206 Section: 27 Block: 4 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Sunation Solar License No: 33412ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump 11 Other Equipment: 20.145kW Roof Mounted PV Solar Energy System w/ (51) REC395AA Modules, Combiner Panel, 80A AC Disconnect, Lineside Tapped in Transfer Switch Notes: Solar Inspector Signature: Date: February 22, 2024 S.Devlin-Cert Electrical Compliance Form fq4v so TOWN OF SOUTHOLD BUILDING DEPT. 631.765-1802 INSPECTION- FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAAUULKING [ ] FRAMING /STRAPPING lvl FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: CR641- 6,27,lea& \V`u ov DATE INSPECTOR OF SOUIyO� # # TOWN OF SOUTHOLD BUILDING DEPT. Comm 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: �>�-��✓ OJr s LIAQ 4- LoaC c��D ca s i1\ sal DATE [ I 2?j INSPECTOR �,, Fisher Engineering Services, ED 509 Sayville Blvd - Sayville -New York 11782 Phone: (631) 786-4419 October 9, 2022 Town of Southold Post Installation Certification Subject: Engineer Statement for Solar Roof Installation Allecia residence—330 Harbor Road, Orient Permit No.: 48206 Install Date: 10/6/2022 The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Fisher Engineering Services, P.C. to be in compliance with the minimum requirements of the Town, the 2020 Residential Code of New York State, 2018 International Residential Code (2018 IRC), Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2017, and the provisions of ASCE 7-16. Sincerely, William G. Fisher, P.E. Licensed Professional Engineer Architectural Design-Residential-Light Commercial Additions-Extensions-Conversions Construction Estimates/Oversight-Expediting-Inspections 1 Form Instructions U.S. DEPARTMENT OF HOMELAND SECURITY OMB Control No.1660-0008 Federal Emergency Management Agency Expiration Date:06/30/2026 JUL - B 2�24 National Flood Insurance Program ELEVATION CERTIFICATE guilding DepaFevation RTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 Copy al"098ifW Certificate and all attachments for(1)community official, (2)insurance agent/company,and(3)building owner. SECTION A-PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name: Sandra Allecia Policy Number: M.C. ouuurny OuecLrruuresti tinaiuuuiy MPL., Unn,Owrc,dnurUi oiuy. rvU.)ur r.v. r-,cuie dnu ocx Mi • Pan Com NAIC Number: Y 300 Harbor Road City: Orient State: NY ZIP Code: 11957 A3. Property Description(e.g., Lot and Block Numbers or Legal Description)and/or Tax Parcel Number: 1000-27-04-05 A4. Building Use(e.g., Residential, Non-Residential,Addition,Accessary,etc.): residential A5. Latitude/Longitude: Lat.41.131291 Long.72.295809 Horiz. Datum:ONAD 1927 ONAD 1983 OWGS 84 A6. Attach at least two and when possible four clear color photographs(one for each side)of the building(see Form pages 7 and 8). AT Building Diagram Number: 7 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s): 1075 sq.ft. b) Is thereat least one permanent flood opening on two different sides of each enclosed area? DYes IONo ON/A c) Enter number of permanent flood openings in the crawlspace or enclosure(s)within 1.0 foot above adjacent grade: Non-engineered flood openings: 0 Engineered flood openings: 0 d) Total net open area of non-engineered flood openings in A8.c: 0 sq. in. e) Total rated area of engineered flood openings in A8.c(attach documentation-see Instructions): 0 sq.ft. f) Sum of A8.d and A8.e rated area(if applicable-see Instructions): 0 sq.ft. A9. For a building with an attached garage: a) Square footage of attached garage: sq.ft. b) Is there at least one permanent flood opening on two different sides of the attached garage? DYes (3No (3N/A c) Enter number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade: Non-engineered flood openings: Engineered flood openings: d) Total net open area of non-engineered flood openings in A9.c: sq. in. e) Total rated area of engineered flood openings in A9.c(attach documentation-see Instructions): sq.ft. f) Sum of A9.d and A9.e rated area(if applicable-see Instructions): sq.ft. SECTION B-FLOOD INSURANCE RATE MAP(FIRM) INFORMATION B1.a. NFIP Community Name: Southold,Town of B1.b. NFIP Community Identification Number: 360813 B2. County Name:Suffolk B3.State: NY B4.Map/Panel No.: 36103CO68 B5.Suffix: H B6. FIRM Index Date: B7. FIRM Panel Effective/Revised Date: 9/25/2009 B8. Flood Zone(s): AE B9. Base Flood Elevation(s)(BFE)(Zone AO, use Base Flood Depth): EL 6 B10. Indicate the source of the BFE data or Base Flood Depth entered in Item B9: OFIS FIRM ®(:nmmirnity r)Ptarminari ®Other: B11. Indicate elevation datum used for BFE in Item B9: ❑NGVD 1929 ONAVD IIPM OOther/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS)area or Otherwise Protected Area(OPA)? ®Yes ®No Designation OCBRS OOPA B13. Is the building located seaward of the Limit of Moderate Wave Action(LiMWA)? DYes ONo FEMA Form FF-206-FY-22-152(formerly 086-0-33)(8/23) Form Page 2 of 8 Form Instructions ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 BUILDING PHOTOGRAPHS See Instructions for Item A6. Building Street Address(including Apt., Unit, Suite,and/or Bldg. No.)or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 300 Harbor Road Policy Number: City: ORIENT State: NY ZIP Code: 11957 Company NAIC Number: Instructions: Insert below at least two and when possible four photographs showing each side of the building (for example, may only be able to take front and back pictures of townhouses/rowhouses). Identify all photographs with the date taken and"Front View,""Rear View," "Right Side View,"or"Left Side View."Photographs must show the foundation.When flood openings are present, include at least one close- up photograph of representative flood openings or vents,as indicated in Sections A8 and A9. Photo One VIEW FROM -- NORTHEAST fill till 1 Photo One Caption: Clear Photo One rr C j VIEW FRO SOUTH ? , 4- c .. C k . a I Photo Two Caption: ' Clear Photo Two FEMA Form FF-206-FY-22-152(formerly 086-0-33)(8/23) Form Page 7 of 8 Form Instructions ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 BUILDING PHOTOGRAPHS See Instructions for Item A6. Building Street Address(including Apt., Unit, Suite,and/or Bldg. No.)or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 300 Harbor Road Policy Number: City: ORIENT State: NY ZIP Code: 11957 Company NAIC Number: Instructions: Insert below at least two and when possible four photographs showing each side of the building(for example, may only be able to take front and back pictures of townhouses/rowhouses). Identify all photographs with the date taken and"Front View,""Rear View," "Right Side View,"or"Left Side View."Photographs must show the foundation.When flood openings are present, include at least one close- up photograph of representative flood openings or vents, as indicated in Sections A8 and A9. Photo One VIEW FROM NORTHEAST 1111 fill, MERIPWA AMEN— Photo One Caption: Clear Photo One qn !fit, VIEW FRO SOUTH I 1,X v i z I ' s w yj -- 4 r Photo Two Caption: Clear Photo Two FEMA Form FF-206-FY-22-152(formerly 086-0-33)(8/23) Form Page 7 of 8 Form Instructions ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 BUILDING PHOTOGRAPHS Continuation Page Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 300 Harbor Road Policy Number: City: Orient State: NY ZIP Code: 11957 Company NAIC Number: Insert the third and fourth photographs below. Identify all photographs with the date taken and"Front View,""Rear View," 'Right Side View," or"Left Side View."When flood openings are present, include at least one close-up photograph of representative flood openings or vents, as indicated in Sections A8 and A9. Photo Three VIEW FROM NORTHWEST 1 f 3' ' e, Photo Three Caption: Clear Photo Three l Al VIEW FROM SOUTHEAST j F MEMO O 4L Photo Four Caption: Clear Photo Four FEMA Form FF-206-FY-22-152(formerly 086-0-33)(8/23) Form Page 8 of 8 r ��o�oSOFFock�oGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT y, x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 hgps://www.southoldtowmy.gov Floodplain Development Permit Application ,PROPERTY INFORMATION:. Flood Zone: FIRM Panel: SCTM#1000-27-4-5 Address:300 Harbor Road city:Orient FZIP:11957 CONTACT PERSON: Name:Tammy Lea/SUNation Solar Systems, Inc. Phone#:631-750-9454 Mailing Address:171 Remington Blvd., Ronkonkoma, NY 11779 PROJECT DESCRIPTION: Installation of Solar Panels - Flat on roof SECTION A:STRUCTURAL DEVELOPMENT(CHECK-ALL THAT APPLY)' Type.bf'Structure Type of Structural Activity ®Residential(1 to 4 families) ❑New structure ❑Residential(more than 4 families) ❑ Demolition of existing structure ❑ Combined use ❑Replacement of existing structure ❑Non-residential ❑Relocation of existing structure ❑ Elevated ❑Addition to existing structure ❑ Flood proofed(attach certification) ❑Alteration to existing structure ❑Manufactured Home R Other: Solar Panels ❑Located on individual lot ❑Located in manufactured home park SECTION-B:OTHER DEVELOPMENT(CHECK ALL THAT APPLY) ❑Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑Connection to public utilities or services ❑ Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑Watercourse alteration (attach description) ❑ Excavation (not related to a structured development) ❑ Other development not listed (specify): By signing below I agree to the terms and conditions of this permit and certify to the best of my knowledge the information contained in this application'is true and accurate.I understand.that no work may start until a permit is issued:The,permit may be revoked'if any false statements are made herein.If revoked,all work must cease until permit is re-issued.Development shall not be used or occupied until a Cert.of Compliance,is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements:Applicant gives consent to local authority or representative to make reasonable inspections .to verify,compliance. , A Application Submitted By(print name):` Maskin - SUNation Solar Systems, Inc. Signature of Applicant: Date: FIELD INSPECTION REPORT DATE COMMENTS �ro FOUNDATION (1ST) ------------------------------------ d C FOUNDATION (2ND) z 0 H ROUGH FRAMING& PLUMBING r r� INSULATION PER N.Y. y STATE ENERGY CODE 05 I 1 FINAL f) ON am LAU ADDITIONAL COMMENTS 9570 /o? �L i- jerX 1022V-5 q o L� O z x d ro H o�OS�fFO(��OG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y� Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y�o• �ao�� Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldto AM.fZov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only (� (7 Ili rin PERMIT NO. Building Inspector: JUL 1 12022 Applications and forms must be filled out in their entirety.Incomplete .applications will not be accepted. Where the Applicant is not the owner;an BUILDING DEPT. TOWN OF SOUTHOLO w Oner's Authorization form(Page 2)shall be completed. Date: OWNERS)OF PROPERTY: Name: Sandra Allecia SCTM# s000-27-4-5 Project Address: 300 Harbor Road_, Orient, NY.11957 Phone#: (631) 323-3916 Email: fourgrand4@verizon.net Mailing Address: 300 Harbor Road, Orient, NY 11957 CONTACT PERSON: Name: Tammy Lea/Sunation.Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma,'NY 11779 Phone#: 631-750-9454 Email:permittin .. sunation.com _ DESIGN PROFESSIONAL INFORMATION: Name: William Fisher Mailing Address: 509 Sayville Blvd, Sayville, NY 1.1782 Phone#: 631-786-4419 Email:bill@fisher-ny_.com CONTRACTOR INFORMATION: Name:Scott_.Maskin/Sunation Solar Systems Mailing Address: 171 Remington_Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 __. Email:permittin sunation.com . 9@_- ,DESCRIPTION OF PROPOSED CONSTRUCTION. ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ 5- iA 6,oo Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY'l N FORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for-the issuance.of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County;New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described:The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors.on premises and in,buildings)for necessary'inspections.False statements made herein are punishable as a Class A'misdemeanor pursuant to Section 210.45 of the New York State'Penal Law. Application Submitted By(print name): ott Maskin BAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this — 1 day of u(u , 20 a a- ary Public TAMMY LEA Notary Public,State of New York Registration No.01 LE6410842 Qualified In olk Count PROPERTY OWNER AU 1-HOR17ATION Commission ExpiresNovember2,20�4 (Where the applicant is not the owner) I Sandra Allecia residing at 300 Harbor Road Orient do hereby authorize Scott Maskin to apply on my b f to the Town o uthold Building Department for approval as described herei . Owner's Signature Date Sandra Allecia Print Owner's Name 2 t D E C E Q W E O��S�ffQc�.0 BU I G DEPARTMENT- Electrical Inspector F ER 2 2 2024 TOWN OF SOUTHOLD c Town Hall Annex- 54375 Main Road - PO Box 1179 o Buffd';ng ne artynant Southold, New York 11971-0959 'y�j0 ao� TOM' of SoutfI phone (631) 765-1802 - FAX (631) 765-9502 iamesh@southoldtownny.gov- seand(aD-southoldtownny.aov APPLICATION FOR ELECTRICAL.INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 2/21/2024 Company Name: DAK Electric Electrician's Name: Dave King License No.: 5120 Elec. email:jgaffga@jtechss.com Elec. Phone No: 631-375-2737 ❑1 request an email copy of Certificate of Compliance Elec. Address.: PO # 1050 Mattituck NY 11952 JOB SITE INFORMATION (All Information Required) Name: Frank & Sandy Allecia Address: 300 Harbor Rd Orient NY 11957 Cross Street: Narrow River Rd Phone No.: 917-560-2072 BIdg.Permit#: & email:jgaffga@jtechss.com Tax Map District: 1000 Section:27 Block: 04 Lot: 05 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New Service Square Footage: Circle All That Apply: Is job ready for inspection?: ��'�'4YES VNO ❑Rough In Final Do you need a Temp Certificate?: ❑ YES F&-/]NO Issued On Temp Information: (All information required) Service SizeF1 Ph❑3 Ph Size: 200 A #Meters 1 Old Meter# 1 ONewService❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 D H Frame Pole Work done on Service? nY ✓ N Additional Information: .qAniir-A I Inriatrn gnmin Amnrnrnnin PAYMENT DUE WITH APPLICATION �v-4- 14�2�� ,A �pSo ,t BUILDING DEPARTMENT-Electrical Inspector •` 'b TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 p Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov -sea nd(&-southoldtownny.aov .F APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date. _ a Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permitting suna_ tion.com Address: 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) G, Name: _.Sandra Allecia Address: 300.Harbor Road Orient NY 11-957 Cross Street: Phone No.: (631) 323-3916 Bldg.Permit#: 0 email: fourgrand4@verizon.net Tax Map District: 1000 Section: 27 Block:4 Lot:5 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of solar. panels - flat on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES/ NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: .A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected- Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION JUL 1 1202.2 ED Request for Inspection FormAs BUILDING DEPT. Tn�niel nF s()UTHOLD fat/( BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD C z Town Hall Annex- 54375 Main Road PO Box 1179 Southold, New York .11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(c-southoldtownny.gov — sea nd0-)southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 12/1/2022 Company Name: SUNation Energy Electrician's Name: Scott Maskin License No.: 33412-ME, 40325-ME Elec. email: permitting@sunation.com Elec. Phone No: 6317509454 ED I request an email copy of Certificate of Compliance Elec. Address.: 171 Remington Boulevard, Ronkonkoma, NY 11779 JOB SITE INFORMATION (All Information Required) Name: Sandra Allecia Address: 330 Harbor Road, Orient Cross Street: Phone No.: (631) 323-3916 Bldg.Permit#: 48206 email: fourgrand4@verizon.net Tax Map District: 1000 Section: 27 Block: 4 Lot: 5 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 20145KW Roof Mounted Solar Photovoltaic System Including: 51 REC REC395AA BLACK w/51 Enphase IQ8PLUS Micro[nverters. 60 Amp fused service disconnect. Fused at 40 Am s. 1-En hase Envoy combiner box with 2 20amp breakers. Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ✓ YES ❑ NO . Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 FJ2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION N Y S I F PO Box 66699,Albany,NY 12206 New York State Insurance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE """""" 753118816 �• k GCG RISK MANAGEMENT INC 100 CHURCH STREET-SUITE 810 NEW YORK NY 10007 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER I CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 670-2 243630 01/01/2022 TO 01/01/2023 12/14/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND 1/� 4 DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 103973329 Im� �lll�II mmmomm�unlnlimoniummUuuII Rig lminifili p�llpl��l WH 00000000000099403304II II Form WC-CERT-NOPRINT Version 3(0 812 9/2 0 1 9)[WC Policy-21606702] U-26.3 64 [00000000000099403304][0001-000021606702][tt2][35782-06][CertNoP-CERT I][01-00001] � CERTIFICATE OF LIABILITY INSURANCE DATE 2/1,oZ/'2"'r' ACORO® THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: The Horton Group PHONE FAX 10320 Orland Parkway ac No Ext:708-845-3000 WC,No): Orland Park IL 60467 ADDRESS: cerfificates@thehortongroup.com INSURE S AFFORDING COVERAGE NAIC# INSURER A:Evanston Insurance Company 35378 INSURED SUNASOL-01 INSURER e:The Continental Insurance Company 35289 SUNation Solar Systems, Inc.171 Remington Blvd INSURERC:AXIS Surplus Insurance Co. 26620 Ronkonkoma NY 11779 INSURERD:Travelers Property&Casualty Company of America 25674 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:1814587611 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY POLICY NUMBER MM/DDI EFF MMIDDEXP LIMITS LTR A GENERAL LIABILITY Y Y MKLVIENV103336 2/11/2022 2/11/2023 EACH OCCURRENCE $1,000,000 DAMTGE TO-RENTED X COMMERCIAL GENERAL LIABILITY PREMISES(Ea occurrence) $300,000 CLAIMS-MADE OCCUR MED EXP(Any one person) $10,000 PERSONAL&ADV INJURY $1.000,000 GENERAL AGGREGATE $2.000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $2,000,000 POLICY X PRO- LOC $ B AUTOMOBILE LIABILITY Y Y 70183082D2 2/11/2022 2/11/2023 COBINED SINGLE LIMIT Ea M accident $1 000 000 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ HIRED AUTOSAUTOS AUTOS NON-OWNED PROPERTY DAMAGE $ 1AUTOS Per accdent C UMBRELLA LIAB X OCCUR Y Y P-001-000795196-01 2/112022 2/112023 EACH OCCURRENCE $3,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $3.000,000 DED I I RETENTION$ $ WORKERS COMPENSATION WC STATU- OTH- AND EMPLOYERS'LIABILITY Y I N TORY LIMITS ER ANY PROPRIETOR/PARTNER/EXECUTIVE❑ N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ D Builders Risk Y Y QT-030-2T010874-TIL-22 2/112022 2/11/2023 500.000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remarks Schedule,If more space is required) Additional Named Insureds:SUNation Service Inc;SUNation Electric Inc;SUNation Commercial Inc;SUNation Cares Inc Additional Insured on a primary and non-contributory basis with respect to general liability and auto liability coverage when required by written contract.Waiver of subrogation applies to general liability and auto liability in favor of the stated additional insureds when required by written contract.Excess follows form. Town of Southold is included as an additional insured as required by written contract and the CG 2012(State,Govemmental agency,or Political subdivision permits Or authorization)is included on the policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road Southold NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD Suffolk County Dept.of Labor,Licensing&Consumer Affairs �1 HOME IMPROVEMENT LICENSE �5 Name SCOTT A MASKIN Business Name • s certifies that the irer is duly licensed SUNATION SOLAR SYSTEMS INC :he County of sufolk License Number:HA4104 Rosalie Drago Issued: 03106/2008 Commissioner Expires: 3/1/2024 ' 1 l 1 , A I • I .» I li I I i i i C.I I ' 4 0. R A' � • Suffolk County Dept of Labor,Licensing&Consumer Affairs i y f r MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN Business Name j This certifies that the bearer Is duly licensed SUNATION SOLAR SYSTEMS INC by the County of suffolk License Number:ME-33412 Rosalie Drago Issued: 06/24/2003 Commissioner Expires: 06101/2023 • f i i • i i r 41 i f � l i I Fisher Engineering Services, P.C. 509 Sayville Blvd • Sayville •New York 11782 Phone: (631) 786-4419 July 7, 2022 Attention: Town of Southold Building Department Subject: Engineer Statement for Solar Roof Installation Allecia Residence-300 Harbor Road, Orient,NY 11957 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system(photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2020- Residential Code of New York State (2020 RCNYS), Long Island Unified Solar Permit Initiative (LIUSPI), 2017 National Electric Code,NFPA 70/2014, Weathering Severe, Wind Exposure Category B, Climate Zone 4A. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting, the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 140 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters 2"x6" on 16c.c. & 3.5"x 6" on 24"c.c. with an actual span of 10'-11", with,plywood roof decking and one roof shingle layer on the house as shown on the drawings. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, r s NEw r William G. Fisher, P.E. f O,p Licensed Professional Engineer r 07 Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections A � C .f t SOLAR'S MOST TRUSTEDREC i' i � I n 3t Roou T EXPERIENCE REE 400wp 25 YEAR PROTRUST ;� 20.E W�T2 WARRANTY 3 LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE RE C PROOUET 5PECIFICATIONS SOLAR'S MOST TRUSTED 1821±2.5[71.7±0.11 _ '• 28[7.1] 901[35.51 460[18.11 9CERTIFICATIONS --- _- _ IEC 61215:2016,IEC 61730:2016,UL 61730(Pending) ❑ + -�! ISO 14001:2004,ISO 9001:2015,OHSAS 18001:2007,IEC 62941 ' 1100143.31 D"E �0- C E 15 ,nrert& 6.0±0.2 [0.24±0.011 -- f� a Y WARRANTY M Standard; RECProTrust o ................................................................._.-No Yes Yes InstalledbyanRECCertified 0 11±0.2 Solar Professional € �*[o.a3±o.o1] System Size All i s25kW 25-500kW ._._...-........ _........... ...._. Product Warranty(yrs) 20 25 25 .............................................................-....._..._.;. _......__..........._........... Power Warranty(yrs) 25 25 25 F' 20.5±0.5 .................._................ .. ......_...._...----....... to.8±0.02] 1200[47.21 - Labor Warranty(yrs) 0 25 10 a� ......................_._............... Power in Year 1 98% 1 98% 98% �' -------- ....................___..........................._.._...................----._....._._...._............ .........*........._........ y I ¢� Annual Degradation 0.25% s 0.25% 0.25% I i 22.5[0.91 I� 671 t3[26A±O.12] _ .-..............._..._._....................._..-. _........-- ...... o---........_..-o �as[t.e1 1 Power in Year 25 92/0 92% 92/0 30[1.21 See warranty documents for details.Conditions apply Measurements in mm[in] 4 GENERAL DATA ^_ MAXIMUM RATINGS 132half-cut REC heterojunction cells St5ubl[MC4PV-KBT4/KST4,12AWG(4mm�) Operational temperature: -40...+185'F(-40...+85"C) Celltype: with lead-free,gaplesstechnology Connectors: in accordance with IEC 62652 a.x.-m".u--�- .-.e......-.I �.. ............................... . .0. 6strin of22 cells in series IP68 only when connected Max[mumsystemvoltage: 1000V ....................................................................................................................... ................................................. -........................................-................................................................. Maximum test load(front): +7000 Pa(146 ibs/sq ft). 0.13in(3.2mm)solarglasswith 12AWG(4mm2)PVwire,43+47in(1.1+1.2m). ....................................................................................................................... Glass: anti-reflection surface treatment Cable: accordancewith EN 50618 Maximum test load(rear): -4000Pa(83.5lbs/sgft)• .............................................................................................. ... ........................................................................I.............................. ........................................................................................................................ Backsheet: Highly resistantpolymer(black) Dimensions: 71.7x40x1.2in(1821x1016x30mm) Max series fuse rating: 25A Max reverse current: 25 A o Frame: Anodized aluminum(black) Weight: 45 lbs(20.5 kg) 'See installation manual formounti"$instructions. .. ... .... .... ......................................................... ..... .............................................................. ..... ... .............. De load Test la / I f y ct ) 3-part,3bypassdiodes,IP68rated Design ad l.s sa et fa or Junction box: inaccdrdancewithlEC62790 Origin: Made in Singapore m Q ELECTRICAL DATA Product Code':RECxxxAA Pure _ 9 TEMPERATURE RATINGS' Power Output-P,Ax(Wp) 385 390 395 400 405 Nominal Module OperatingTemperature: 44'C(±2'C) ...................... .. .. .. .. ... ......................................................................_........................._........................._........................... .................................................................................... ................................. Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 Temperature coefficient OfPMAX: -0.26%/'C ......................... ................... .. ............................................................-........................................................................ ........................................................................................................... o Nominal PowerVoltage-VmppM 41.2 41.5 41.8 42.1 42.4 Temperature coefficient ofVoc: -0.24%/'C ........................ ........................................................................................................................ u= H Nominal Power Current-IMpp(A) 9.35 9.40 9.45 9.51 9.56 Temperature coefficientoflsc: 0.04%/'C N . . ..... ....... ... ..... Ln Open Circuit Voltage-Voc(V) 48.5 48.6 48.7 48.8 48.9 'The temperature coefficients stated are linearvalues .......................... ..... . ............................__...................................................................................................... Short Circuit Current-Isc(A) 10.10 10.15 10.20 10.25 10.30 .............................................. .... .................................................................................................................................. ........ Power Density 19.3 19.6 19.8 20.1 20.3 ( LOW LIGHT BEHAVIOUR ...... .... ................................................._........................... Panel Efficiency(%) 20.8 21.1 21.3 21.6 21.9 Typical low irradiance performance of module at STC: N R; 0 Power Output-PMAX(WP) 293 297 301 305 ' 309 .......................... .......__............................................................................-.... F Nominal PowerVoltage-VmppM 38.8 39.1 39.4 39.7 40.0 61 i i � _. p .................__... ...... _... ........_.....................-_.._........_......................................._.........._............_........................... d o - ---- -- ------ g Nominal Power Current-Impp(A) 7.55 7.59 7.63 7.68 7.72 N Z .... ......................................... '""""'"""""""""""""""" """""""" """".................................................._...................................................:_..................................................... W------------- --------- ----, Open Circuit Voltage-Voc(V) 45.7 45.8 45.9 46.0 46.1 W o .. .......... ... ......................................................... ......................_........................._................................................................ Short Circuit Current-Isc(A) 8.16 8.20 8.24 8.28 8.32 w m m Irradlance(W/m')p rr Values at standard test conditions(STC:airmass AM1.5,irradiance 10.75 W/sq ft 0000 W/m'),temperature77°F(25"C),based on a production spreadwitha tolerance ofPam,Va&Ic±3%within one watt class.Nominal module operatingtemperature(NMOT.airma5s AM 1.5,irradiance 800 W/m',temperature 68'F(2(°C),wind5peed33 ft/s 0 m/s).'Wherexxx indicates the nominal power class(P_)at STC above. Founded in 1996,REC Group is an international pioneering solar energy REC C company dedicated to empowering consumers with clean,affordable + "` solar power.As Solar's Most Trusted,REC is committed to high quality, innovation,and a low carbon footprint in the solar materials and solar www•recgroup.com panels it manufactures. Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs in North America, Europe,and Asia-Pacific. 0� W f n ,I.ENPHASE, r M-k v!" QQ kT 04 IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to install is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling Enphase High productivity and reliability ii Produce power even when the year limited I grid is down warranty 17 • More than one million cumulative Part of the Enphase Energy System,I08 Series IQ8 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming CERTIFIED Complies with the latest L_ SAFETY -A advanced grid support Connect PV modules quickly and easily to I08 Series Microinverters are UL Listed as Remote automatic updates for I08 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements IQ8SP-DS-0002-01-EN-US-2021-10-19 IQ8 and IQ8+ Microinverters INPUT DATA(DC) IQB-60-2-US 108PLUS-72-2-US Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range v 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage v 50 160 Max DC current'[module]so] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA(ACI 08 .0 0:• Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range3 V 240/211-264 Max continuous output current A 1.0 1 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit4 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -400C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 1O8SP-DS-0002-01-EN-US-2021-10-19 r SERIES 100 FLASHED L FOOT SnapNrack Residential - Systems The SnapNrack line of solar mounting T _ - systems is designed to reduce total Y g ;.ty �t..k."� Ft.. egeia...ciy'y,'= .+. r.=�,v. zy!ri"'• installation costs. The system features W technical innovations proven on morea: than 20OMW of solar projects to simplify installation and reduce costs. Flashed L Foot Simplified R, SnapNrack Series 100 Flashed L Foot Kit is an innovative .. ,. solution to provide a long lasting watertight seal over t the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps: shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www.snapnrack.com/contact SnapNrack- Patent Pending pW MR(Du 1Nnu) syzftmo �t I i Y� i - Flashed L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1`spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions SNAPNRACK CHANNEL NUT �SNAPNRACK 91 DEGREE L-POUT,CLEAR -5/16.18 FLANGE NUT r5/IB-18 X LIN BOLT WITH SPLrr LOCK wAsKER .-SNAPNRACK COMPOSITION FLASHING l s 3.13 \\-SNAPNRACK L-FOOT BASE .88 SnapNrack Flashed Foot TechnicalData Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapNrack, PV MounUng Systems (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. ti A SERIES 100 ROOF MOUNT SnapNrack Solar • • Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation - ' quality on more than 350 MW of solar installations. `;!` .:.....5"'!S.4_"ry..:e'• _lam=^%,�.'�:%••+"i".�`.. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic(PV) module installation system.Series 100 UL is Listedto the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules �L. LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Standard Rail SnapNrack Bonding P Bolt with Split- Splice Insert Split-Lock .he s_ Lock Washer SnapNrack Bonding '` SnapNrack Adjustable End SnapNrack �` Splice Clamp Top Bonding Base > Mid Clamp SnapNrack SnapNrack Bonding - Bonding SnapNrack Adjustable End Stainless Channel Nut Bonding Bolt with Clamp Bottom Stainless Hardware with Channel Nut Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack BondingWasher Adjustable End Clamp SnapNrack Bonding Mid Clamp Standard Rail Spllce SnapNrack Ground Lug 10-6 AWG Copper Wire — ' SnapNrack Ground Lug Assembly ONE REQUIRED PER ROW OF ■ �• MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer IF IF F IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff " Clamp Assembly SnapNrack Serrated Stainless_,.,S SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar c Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack Stainless SnapNrack °og 92 Degree Flange Mill Finish L Foot Bolt Standoff of SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hale SnapNrack Base Shown) SnapNrack��� •••��� L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding J SnapNrack Bonding SnapNrack Metal Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrackPatent Pending • • UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship(download full details at snapnrack.com) SnapNrack- Solar Mounting Solutions (877) 732-2860 www.SnapNrack.com a Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved. ®-UTILTfY METER,PLAN KEY SERVICE DISCONNECT 60a� PROPOSED RESIDENTIAL 1-0 COVER SHEET B-SUPPLYSIDECONNECTION A11-1 PARTIAL ROOF PLAN U_-AUTOMATICTRANSFERSWITCH PHOTOVOLTAIC SYSTEM Ai-2 ATTACHMENT SPACING PLAN F1-GAS METER Ai-4 ROOF ACCESS PLAN E -MAINSERVICEPANEL FRONT OF HOUSE- FACING STREET OR DRIVEWAY ©-SUB PANEL SUNATION SOLAR SYSTEMS NYSERDA Si-1 STRUCTURE ROOF S ATS® 171 REMINGTON BOULEVARD INSTALLER 4355 E1-1 ONE-LINE DIAGRAM �' -WIRELESS ROUTER --- ACCESS —r — RONKONKOMA, NEW YORK 11779 NUMBER ®-INVERTER -38°- - E2-1 PV LABELS ®-ENPHABEIOGDMBNER — M P G1-1 PV PHOTOS ) TFENCE Allecia Residence Q-PANEL PHOTOVOLTAIC B (Ex') M-ELECTRIC VEHICLE GHA83ER - 300 Harbor Road, Orient, NY 11957 ®-ENPHASE ENVOY _ D_ [� pp /] -SENSE CONSUMPTION MONITOR Drawn By. S. Beattie - 07/07/Gl)22 -AC DISCONNECT IO •TESLA GATEWAY -TESLA POWERWALL 0 '`4 m- F✓{/ -ENPHASE K)SYSTEM CONTROLLER ',r,���p� FISHER ENGINEERING SERVICES, P.C. Q-ENPHASE ro LOAD CONTROLLER m J c^� S� 509 Sayville Boulevard Z o §-ENPHASE Io 10 BATTERY Z W Sayville, New York, 11782 ®-ENPHASE ro 3 BATTERY n •-J s. -•- � Licensee No. 074659 44 44 ® GENERATION PANEL O- ; 4" (631)-786-4419 BACKED UP LOADS CENTER Z �• a �'�V � Bill@Fisher-NY.com O•VENT PIPE •• •EXTERIOR LOCATION 44- Building Review Note 1ST FLOOR LOCATION BASEMENT LOCATION 44 44Town building examiner has received the enclosed document for minimum acceptable -GARAGE LOCATION plan submittal requirements of the town as specified in the building and/or Residential Code of the State of New York. This review does not guarantee compliance with that ❑ code. that responsibility is guaranteed under the seal and signature of the New York 44State licensed design professional of record. That seal and signature has been PROPOSED PV SYSTEM ROOF interpreted as an attestation that,to the best of the licensee's belief and information Module Type/Qt 51 REC395AA BLACK ACCESS-36"- the work in this document is: YP Y� ( ) -3s^- 0 Accurate • Conforms with governing codes applicable at the time of submission Module Dimension: 71.69"x 40"x 1.18" (24)PROPOSED PV MODULES — (27)PROPOSED PV MODULES Conforms with reasonable standards of practice and with view to the Module Weight/PSF: 45 Ibs/2.3 PSF slicensee.guarding of life,health,property and public welfare is the responsibility of the Micro Inverter: (51)Enphase IQ8PLUS-72-2-US Structural Statement System DC Rating: 20.145 kW APPROVED AS NOTED FLUOR ZONE The existing structure is adequate to support the new loads imposed by the Estimated AC Production: 18,807 kWh/yr — photovoltaic module system including uplift and shear. The existing rafter sizes DATE: .P.# and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. Production Source: Aurora COMPLY WITM CAPTER "46" FEE: EP , PV Notes FLOOD DAMAGE PREVENTION NOTIFY BUILDING DEPARTMENT AT SOl1TFIOLD TOWN rOrr 1. This PV system has been designed to meet all current and applicable fire 765-1802 8 AM TO 4 `PIM FOR THE prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be FOLLOWING INSPECTIONS: D provided where necessary. An in depth description of each applicable code 1. FOUNDATION NO REQUIRED reference and exception for any codes is depicted on the PV-1 plate of this FOR POURED CCwCRETE drawing package. ID2. Roof shall have no more than a single layer of roof covering in addition to the JUL 1 12092 2. ROUGH - FRAV!;1G & PLUMBING solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more N 3. INSULATION than 6-inches above the surface of the roof. BUILDING DEPT. e FINAL - CGr�:" "'iN MUST 4. Weight of the installed system shall not exceed more than 5-psf TOWN' DI SOUTH ,LD 5. Any plumbing vents are not to be cut or covered for solar equipment installation. BE COMPLETE , .0. Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN ALL CONSTRUC T i"'_tN :BALL MEET THE inspection. SCALE:N.T.S. RtOUIREMENTS Gr'HE CODES OF NEW This PV system has been designed to meet the minimum design standard for building YORK STATE. NOT RESPONSIBLE FOR Code. andther structures of the ASCE 7-16 and the 2020 New York State Residential DESIGN OR CONSTRUCTION ERRORS. J PVImO COMPLY WITH ALL CODES OF OCCUPANCY OR JOB# 22493 NEW YORK STATE & TOWN CODES COVER PAGE AS REQUIRED AND CONDITIONS OF USE IS UNLAWFUL REVISION # N/A WITHOUT CERTIFIC< S U NAT ION "& i- �BOARD OF OCCUPANCY I oe (e t rL y REVISED BY N/A %AFHft7nGI�RUSTEES ELECTRICAL � ---- INSPECTION REQUIRED 6"CC6v b(.0 CIRCUIT 2 <, OF NF/y �O R.R.-2"X 6" 3' Q 16"O.C. 1001 a CIRCUIT 4 CIRCUIT 3 — I I • G(J s�oa // c 9 \�� 10'-10" • • 10'-10" • • FISHER ENGINEERING • I I • SERVICES,P.C. • • 509 Sayville Boulevard • • • • • I I • . Sayville,New York,11782 • • • • • � Licensee No.074659 • • • (631)-786-4419 Bill@Fisher-NY.com R.R.-3.5"X 6" I • --- SUNNTION • c 24°O.C. I • ENERGY • • SUNation Solar Systems STRUCTURE CHANGE • I I • 171 Remington Blvd. • Ronkonkoma,New York 11779 • • • (631)-750-9454 G U TT E R 33'-5" I RIDGE I 33'-4YZ' GUTTER __ —_ I I -•• NYSERDA INSTALLE R 4 NUMBER 3�55� •• JOB NUMBER 2249 3 . . . • LO 1ji, /-F 4.tI I P CIRCUIT 1 0 o 0)z d aj m 3' 0 N 1 1 Cr o m Z Q Iz C6 23'-1y2' 23'-2" Q a m ROOF 2 ROOF AREA RIDGE CAPPING PHOTOVOLTAIC MODULE ROOF 1 _ C (TYP.) (TYP.) c o M Roof# Roof Description Modules Azimuth Tilt Pitch Attachment Spacing: Portrait Attachment Spacing: Landscape Interior Edge Corner Interior Edge Corner 1 Southeast Roof 27 1150 210 5.6/12 48" 32" 16" 64" 64" 48" 2 Southeast Roof 24 1150 210 5.6/12 48" 32" 1611 64" 64" 48" N 3/16" = V-0" Al = 1 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS of NFL (NY) R324.6 Roof access and pathways. Roof access, pathways and �P\\om Fs IO setback requirements shall be provided in accordance with Sections �'� R324.61 through R324.6.2.1. Access and minimum spacing shall be required to provide emergency access to the roof,to provide pathways _ 1 to specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. �a //0-W40'9 Exceptions: 1. Detached, nonhabitable structures, including but not limited to FISHER ENGINEERING detached garages, parking shade structures, carports, solar FRONT OF HOUSE - FACING STREET OR DRIVEWAY SERVICES,P.C. 509 Sayville Boulevard trellises and similar structures, shall not be required to provide Sayville,New York,11782 roof access. - --— ----- -- - ---- -- Licensee No.074659 2. Roof access, pathways and setbacks need to be provided ROOF SSC ATS (631)-786-4419 -where the building official has determined that rooftop ACCESS Bill@Fisher-NY.com �- operations will not be employed. 3611- - 3. These requirements shall not apply to roofs with slopes of two — - --- RE P r units vertical in 12 units horizontal (17-percent slope)or less ) _ FENCE SUN^T��N' [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate - B (EXT) SUNation Solar Systems roof planes from lowest roof edge to ridge and not less than 36 inches - Ronkonkoma,New York 11779 171 Remington Blvd. (914 mm) wide, shall be provided on all buildings. Not fewer than one (631)a50-9454 pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photovoltaic array, a pathway not less than NYSERDA 36 inches (914 mm) wide shall be provided from the lowest roof edge INSTALLER 4355 to the ridge on thee same roof plane as the photovoltaic array, on an NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. 41W IQ Pathways shall be over areas capable of supporting fire fighters -- JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal obstructions such as vent pipes, conduit, or mechanical equipment. r Z 22493 Pathways on opposing roof slopes shall not be located along the same co 0 plane as the truss, rafter, or other such framing system that supports - Q the pathway. < J m Exception: Z Z Lu --_- 1. Access pathways shall not be required on roof slopes containing � j D 'i > — photovoltaic modules, panels, or an array where the opposing —{ _ r, or adjacent roof slope is an access roof. rn N z r Z T N Access Roof-A roof surface that: Z o C: Q o 4 1. Can be accessed from the ground by the fire service. ) a a, 2. Is capable of providing fire service access to the ridge or peak p a) .76 of an opposing or adjacent roof surface that contains LL c co Z � photovoltaic modules,panels,or an array. o - a, 0 ui 3. Is relatively free of vents, skylights,conduits, mechanical a �`o m equipment and other such obstructions. A Cl) c 4. Does not contain photovoltaic modules, panels or an array,or is =o CZ a single ridge roof where the maximum edge to edge width of --- -- M o the photovoltaic panel system does not exceed 33 percent of the ridge length. ❑ [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be ROOF located less than 18 inches(457 mm)from a horizontal ridge. ACCESS -36"- [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion (24) PROPOSED PV MODULES (27) PROPOSED PV MODULES of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches(914 mm)wide shall be provided to the emergency escape and rescue opening. 3/16"= V-0" Al =4 ROOF ACCESS PLAN OF NFjy Typical Attachment Method n /'O 0740'9 W � SNAP'N'RACK ULTRA RAIL L-FOOT AND RAIL ASSEMBLY FISHER ENGINEERING SERVICES,P.C. RIDGE RIDGE 509 Sayville Boulevard Sayville, PHOTOVOLTAIC 23'-1.5' PHOTOVOLTAIC 0'-0" Licensee 82 nsee No.074659 MODULE MODULE 631)-786-4419 Bill@Fisher-NY.com (2)S.S. 5.OMM X SUNNTION 3/4"MODULE SPACING 3/4"MODULE SPACING WOOD SCREW FASTENER BETWEEN ROWS AND BETWEEN ROWS AND COLUMNS(TYP.) COLUMNS(TYP.) RAFTER RAFTER— RT-MINI ROOF 2"x 6"/16"O.C. 3.5"x 6"/24"O.C. ATTACHMENT SUNation Solar Systems RAIL RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 HEADER�� (631)-75D-9454 2"x S'(SISTERED) (1)LAYER ASPHALT o IN POSTED DOWN TO SHINGLE(TYP.) S EXISTING INTERIOR BEARING WALLS o INSTALLER 4355 _ LOAD BEARING WALL // NUMBER JOB NUMBER 22493 E%7E"x)" SOFFR SOFFR EXTERpR ACTUALSPAN WALL AC"W&SPAN WALL PLYWOOD DECKING 10'-11" 10'-11" (TYP.) 18'-2" - 18'-2" - WOOD FRAMING (TYP.) PARTIAL ROOF SECTION (TYP.)-ROOF"1&2" PARTIAL ROOF SECTION(TYP.)-ROOF"1&2" ATTACHMENT TYPE APPLIED TO-ROOF"TYP" SCALE: N.T.S. SCALE: N.T.S. r Lr) N 0) N r O r N Z Q) Z 0 SOLAR MODULE FRAME O V +-: NOTE:3/4"SPACING BETWEEN MODULE ROWS Q .� Rafter Size/Spacing Max Span Layers Sheathing AND COLUMNS. Roof P 9 P Material Y 9 T ¢ to O ai 1 *VARIES* 10'-11" Composite Shingles 1 Plywood es HEIGHT ADJUSTABLE LL - nor L-FOOT(TYP.) Z (Z M m 2 *VARIES* 10'-11" Composite Shingles 1 Plywood END CLAMP LU v a:° (TYP.) _� _Q) �� SNAP'N'RACK N Q 0 Our- 6.o' ULTRA RAIL i HEIGHT OFF OF ROOF SURFACE Q C�J RT MINI 2 (TYP.) Typical Module PEST WRAP CUT Side Profile AWAY FOR CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN I SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL UN S 1 1 GROUND SNOW SPEED(MPH.) NT TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY TEMPERATURE RE FLOOD HAZARD AIR FREEZING INDEX TEMPERATURE LOAD EFFECTS ZONE SPECIAL WIND ZONE WEATHERING FROST LINE DEPTH TERMITE REQUIRED MODERATE TO SEE PLANS 20 PSF 140 B NO 2 B SEVERE 3'0" HEAVY 15 DEG N/A EXAMINER 599 51 STRUCTURE OF NFL �P\���m �•F,s�JO n - �J FISHER ENGINEERING SERVICES,P.C. Enphase A/C Branch Circuit (typ.) 509 Sayville BoulevardSayville,New York,11782 120/240v Licensee No.074659 Utility Service (631)-786-4419 Enphase Microinverter(typ.) Bill@Fisher-NY.com SUPPLY-SIDE COMBINER /� SUNATION PANEL Module J-Box(typ.) PANEL � EXISTING GENERATOR • • • • • • SUNation Solar Systems 171 Remington Blvd. PV Module(typ.) 200A 200A Ronkonkoma,New York 11779 (631)-750-9454 EGC Attached To Ra�il( p.) MAIN MAIN NYSERDA 4 3 0155 5 INSTALLER ENPHASE GATEWAY NUMBER - - - (N wads.montonne"nN) �P2pA zPtsa A� JOB NUMBER °rrcurt#' . . 22493 CONDUIT AND CONDUCTOR SCHEDULE ENPHASE BRANCH CIRCUIT#1 2PWA Circuit#2 TAG CONDUCTOR CONDUIT RUN ENPHASE BRANCH CIRCUIT#2 1 4 ENPHASE BRANCH CIRCUIT#3 Cir Pcuit#3 80A TYPE GAUGE QUANTITY TYPE SIZE LENGTH MAIN ENPHASE BRANCH CIRCUIT#4 2PZOA 1 Enphase Q-Cable 12 8 WA WA 15' Circuit#a EGC G G G G 2 Type NM 10 8 N/A N/A 30' AUTOMATIC MAIN 3 HWN-2 10 8 PVC SCH.80 1.25" 15' 1 3 ENPHASE A/c TRANSFER SERVICE GC 8 1 PVC SCH.80 1.25" 15' IQ COMBINER DISCONNECT SWITCH PANEL ROOF ATTIC EXTERIOR J SERVICE RATED 4 HWN-2 4 3 PVC SCH.80 1.25" 10, 4 ENCLOSURE 6 GC 8 1 PVC SCH.80 1.25" 10, MIN.2N. 2k AIC Ln CV 5 HWN-2 3 3 PVC SCH.80 1.25" 10, 0) O BUILDING r- N 6 GC 6 1 N/A N/A 10' GROUNDING � ELECTRODE Z z O 0 U }; I`_ � O Q LD r O 0 0 LL cc 7C)- a� _ Z M co Circuit# PV Module otya Micro-Inverter Qty. Maximum AC Operating Current ; cc Uj 1 REC395AA BLACK 13 Enphase IQ8PLUS-72-2-US 13 15.73 A N Q m 2 REC395AA BLACK 13 Enphase IQ8PLUS-72-2-US 13 15.73 A = 3 3 REC395AA BLACK 13 Enphase I08PLUS-72-2-US 13 15.73 A o p co 4 REC395AA BLACK 12 Enphase I08PLUS-72-2-US 12 14.52 A Maximum AC Operating Current (Total) 61.71 A E1 = 1 ONE-LINE DIAGRAM i LABEL LOCATION: LABEL LOCATION: �P�� OF G. s� WARNING:PHOTOVOLTAIC CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ ServiceDisconnectMAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE P URCE CEILINGS/FLOORS OR_MORE THAN 10'. DISCONNECT IF APPLICABLE. • • NEC 2017 690.31(G)(3) NEC 2017 705.10 746Disconnect 5�„�\? LABEL LOCATION: Second MAXIMUM AC OPERATING CURRENT SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND Located FISHER ENGINEERING CURRENT VALUES ON DISCONNECT LABEL. SERVICES,P.C. • OPERATING 509 Sayville Boulevard NEC 2017 690.54/NEC 2017 690.13(B) Sayville,New York,11782 NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO Licensee No.074659 + THE BUILDING MAIN SERVICE DISCONNECT. (631)-786-4419 Bill@Fisher-NY.com ARN I G l his building is equipped with an r Disconnect Interconnected Electric Power � SUNNTION Production Source ELECTRIC SHOCK HAZARD DO NOT REMOVE THIS TAG SUNation Solar Systems Source Type: 171 Remington Blvd. DO NOT TOUCH TERMINALS Solar Photovoltaic Ronkonkoma,New York 11779 TERMINALS ON BOTH THE LINE AND Primary Service Disconnect Disconnect is Located: Interior: (631)-750.9454 LOAD SIDES MAY BE ENERGIZED Basement Garage: Exterior NYSERDA Located 4355 IN THE OPEN POSITION Service Ri Side other LocaFront — tion:—LH side • • • IIN UMBER;TALLER PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE WHENEVER THEY ARE EXPOED TO SUNJGFIT __ _ SUNation Solar Systems JOB NUMBER 631-750-9454 EQUIPPED WITH RAPID www.sunation.com SHUTDOWN 22493 � N O) O r N } t\ Z (1) z O O 0 O c Q 0 .� (D O Z I U M CO O W it U) Q 0 m TZ cts s= O O Q M E2= 1 PV LABELS 1�/•'l of NEB H id IN as FISHER ENGINEERING SERVICES,P.C. _ 509 Sayville Boulevard Sayville,New York,11782 Licensee No.074659 y � (631)-786-4419 Bill@Fisher-NY.com SUNATION -� SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 _ - `c/1 — �l (631)-750 9454 NYSERDA INSTALLER 4355NUMBER a. r--JOB NUMBER 22493 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF to N CD = cc ° LL tD _ Z o `° W (3) or U) L` A - cn Q o SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP GI = I PV PHOTOS