Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51181-Z
� spr� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51181 Date: 09/13/2024 Permission is hereby granted to: 46770 Rt 48 LLC 127 Stirling Ave Greenport, NY 11944 To: install roof-mounted solar panels on existing building as applied for. Premises Located at: 46770 CR 48, Southold, NY 11971 SCTM#55.-5-9.1 Pursuant to application dated 07/12/2024 and approved by the Building Inspector. To expire on 03/15/2026. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -NEW CONSTRUCTION $125.00 CO Commercial $100.00 Total S325.00 biilding Inspector a TOWN OF S®'[JTHO LD — BUILDING DEPARTMENT G Town Hall Annex 54375 Main road P. ®. Box 1179 Southold, NY 11971-0959 ti Telephone (631) 765-1802 Fax (631) 765-9502alit ! I Date Received d E' For Office Use Only p PERMIT NO, 5 Building Inspector: JW Applications and forms must be filled out in their entirety.Incomplete ,o' applications will not be accepted. where the Applicant is not the owner,an Ownees Authorization formes(Page 2 shall be coma feted, ( g P comp Wed. / a l0 � Lf e OWNER(S)OF PROPERrfv C E Name-Jo ( o4-k►-,1 SCTM#1000- �JJ ,�O-0�_ c7U _ OO`1,0C�1 Project Address: 4(c 7 7D 60 ttn f RlL Z} F S 0 lit.�p 1 1 J LI, 1 1 9-7 t Phone#: (3 1- 3 8 2 • -7®L" I Email: P-5— l�-S Q. (f 9.,S ,5,Cs) Mailing Address: 4 VQ -2b OAFL441+ K -f ' �S 0 L -4- i ) M q CONTACT PERSON: � Name: LD r-rA i n< — D e r4t ,_. Mailing Address: -7 470 U odd, 61VYs Mx,4i o )tqJ.-L, gl Phone#: Q -7 0I Email: +5 DESIGN PROFESSIONAL INFORMATION. Name: Mailing Address: Phone#: Email: f CONTRACTOR INFORMATION: pp Name: 1e.inen ►if-� Mailing Address: 4 S VYj M 4,44 C K Phone#: W Q (� .") Lit Email: ptayb4s C "s 's b com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ther I nS4-a 0 PV S�J S4't-M $ Will the lot be re-graded? ❑YesANo Will excess fill be removed from premises? ❑Yes o s i 1 PROPERTY INFORMATION Existing use of property: COmmp'.Y I�� Intended use of property: b vyn n1ZYu Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ONo IF YES,PROVIDE A COPY. Check Box After Rea dIng., The owner/contractor/design professional Is responsible far all drainage and storm water Issues as provided by apter 236 of the Town Code.APPUCATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable taws,Ordinances or Regulations,for the construction of bultdings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with an applicable laws,ordimnces,building code, housing code and regulations and to admit authoraed Inspectors on premises and In buildingls)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 21CAS of the New York State Penal law. Application Submitted By(print name):Lorraine Di Penta SAuthorized Agent ❑Owner Signature of Applicant:C&I" Date: 1L lZy STATE OF NEW YORK) SS: COUNTY OF Suffolk Lorraine DiPenta being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this —LLday of ,7fJ i � blots ublic PROPERTY NE AUTHORIZATION Not"ry LOUb Io,St OME of New'Yark (Where the applicant is not the owner) No.01R0631481 ltrlalffied in Suffolk County Expires November 17",2 1, h F� } rrj+'1 residing at 4'(O "? -' Cv Commission+!-� K� ~ apply o hereby authorize E �� k to on my behalf to the Town of Southold Building Department for approval as described herein. OW f r' Igna Date n Print O ner's Name 2 BUILDING DEPARTMENT- Electrical Inspector 4V, TOWN OF SOUTHOLD ae Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 �� Telephone (631) 765-1802 - FAX (631) 765-9502 �T A ` r o er so ltholdtta rftn a - soand southolidtownn . ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5 o1 y Company Name: P, 1eMCA4 E r) .- L,L•C..) Electrician's Name-Jo. nrot--., M i y)n0 K License No.: - Elec. email: Elec. Phone No: -IoWoI3 [91 request an email copy of Certificate of Compliance Elec. Address.: - 4-70 ,�SL)ram -. 0Ve" . ° , I pu JOB SITE INFORMATION (Ail Information Required)�0 ►� -Flo+l e_r-oYl Name: Address: , ')"]p Ccl lw, i!d II c Cross Street: Uuri Phone No.: (46 1 .. °' S a BIdg.Permit #: 5//93email: Pf,,1 �,a 15 Tax Map District, 1000 Section:0S S: v`D, Block: b S , o c Lot:0 ei.()0 1 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: 1-1 YES Z NO F] Rough In Final Do you need a Temp Certificate?: F YES fR NO Issued On Temp Information: (All information required) Service Size1 Ph[:]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Ll Y RN Additional Information: PAYMENT DUE WITH APPLICATION Ap-MkIN11 New York State Insurance Fund PO Box 66699,Albany,NY 12206 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) ^A A A"A 823336604 ROBERT S FEDE INSURANCE AGENCY fe , 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 i POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 962287 07/13/2024 TO 07/13/2025 7/11/2024 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/IWWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK SWAT S7*1 NNE FUND 4 DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:743799006 iiaa� DATE(MMrD CERTIFICATE O LIABILITY INSURANCE 7/ 4 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UP�NHICERTIFICATE HOLDER. THIS ERTIFICATE DOESNOTAFFIRMATIVELY OR NEGATIVELYAMEND, EXTEND OR ALTER THE COVEFFORDED BY THE POLICIES ELOW. THISCERTIFICATE OF INSURANCE DOES NOTCONSTITUTE A CONTRACT BETWEEN THEG INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. if the certificate holder Is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy„certain policies may require an endorsement. A statement on this certificate does not confer rI hts to the certificate holder In lieu of such endorsement(p PRODUCER CON ROBERTS.FEDE INSURANCE AGENCY A rT MAIL r 60 23 GREEN STREET,SUITE 102 rM1W` • ° - "° — -•-• --- HUNTINGTON,NY 11743 AOOREss"' R OBERTS.FEDE INSURANCE INSLIRE6R S AFFORDING COVERAGE ............. NAIC# INSURER A.,ADMIRAL INSURANCE COMPANY 24856 -FUND D INSURERB: ELEMENT ENERGY SYSTEMS INsuRERo 1' 62 SOUND AVENUE INSURERE: ITUCK,NY 11952 - INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE'.BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT„TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. L TYPE OF INSURANCE Pou o POLIC POLICY NUMBER D IDDfYYY"Y LIMITS COMMERCIAL GENERAL LIABILITY CA00005380701 EACH OCCURRENCE S 1,000,000' A co X X 7I14/2024 7/14/2025 CLAIMS-MADE ®OCCUR � E � I ����'�, a 3oo„000 IMA389203C 7/19/2024 7/19/2025 MED EXP OM ono person) $ 5000 X .... PERSONAL 8 All INJURY $ 1000000 G N'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 PRO- POLICY rI JECT 0LOC PRODUCTS-COMP/OP AG6 ''ffi, OTHERr � s AUTOMOBILE LIABILITY SINGLE t $ auT COMBINED INEn a n ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) E - HIRED NON-OWNED P -P DAMI AUTOS ONLY AUTOS ONLY (Per ac4deral S S UMBRELLA LIAB OCCUR EACH OCCURRI NCf IXCESSLIAB OCAIMS.MADE AGGREGATE DED IRETENTIONS' d WORT E'IRS COMPENSATION SA ....PER - 124494445 AND EMPLOYERS'LIABILITY Y f N 7/13/2024 7/13/2025 E L.EACH ACCIDENT S 1 000 000 ANY PIROFURIE CORIPISFaTI'WPR1FXEC;.ITIUE I OFMC'ERNEMSER EXCE 6ED? � N I A (Mandatory In N11) E.L.DISEASE=POLICY LIMIT 5- 1. E.L.DISEASE-EA FMPL I I yy��oe,domcrJpo ratilrer o _....... 0 kadRPT10N OF OPEERA frONS below dlAl f R NY State DBL DBL567527 1/11/2024 12/31/2025 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED- CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold, NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Rai>'e,�l`S. cede. ©19'88.2015 ACORD CORPORATION. Ahrights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD rwt Workers' Compensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK, NY 11952 1 c.Federal Employer Identification Number of Insured I Work Location of Insured(Onty required if coverage isspearrcaNylimitedro or Social Security Number certain locations in New York State,i.e.,wrap-up Policy) 823336604 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD i 54375 MAIN STREET 3b.Policy Number of Entity Listed in Box"I a" SOUTHOLD, NY 11971 DBL567527 Y 3c.Policy effective period 01/01/2024 to 12/31/2025 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penetly oi perjury.I certify tft t I am an authorized'representative or Licensed agant of the Insurance carrier referenced Zove and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2024 By .� (Signature of Insurance carrier's authorized representative or NYS Licensed Insurance Agent ofth t Insurance carrier) Telephone Number Name and Title LeSton 11Val h Chief Executive Offer p 1'f_ 8�100 .. ,,. IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5113 is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law.It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200, Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 413,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board„The above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Lavw(Articte 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 11111111Duimiiini0iii1iiiili11iuiiimillIIIII Additional Instructions for Form D13-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in Box 1a for disability and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law. The insurance carrier or its licensed agent will send this Certificate of Insurance Coverage(Certificate)to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier. This Certificate Is issued as a matter of information only and confers no rights upon the certificate holder.This Certificate does not amend,extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This Certificate may be used as evidence of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Motet Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract Issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Insurance Coverage for NYS disability and/ or Paid Family Leave Benefits or otherauthorized proof that the business is complying with the mandatory coverage requirements of the NYS Disability and Paid Family Leave Benefits Law. NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand and twenty-one, the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b)The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits and after January first,two thousand eighteen,the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (12-21)Reverse S7/ 4 WIGI CLAUDIO SCIANDRA, P.E. 240 Windgate Drive-UnitA-227,Chester Springs 19425-3643 Cell.631-747-7497-E-mail:Ics4d0aol.6om Thursday, May 9th, 2024 Element Energy Systems 7470 Sound Avenue Mattituck, New York 11952 Attention: Dayoung Gong Re: Fifty-three(53)485 W PV Roof Top Solar Panels. 25706 kW DC_Total Output, for Peconic Water Sports.46770 Country Road 48 Southold, New York 11971 Dear Ms. Gong, Pursuant to your request, I have reviewed the following information regarding the subject roof top solar panels arrays: Cover Sheet with Site Visit/Verification prepared by E2Sys representative identifying specific site information including size and spacing of rafters for the existing roof. Design drawings of the proposed system to include site plan, roof plan, mounting details for the solar panels.This information was prepared by E2Sys and will be utilized for approval by the Town of Southold and for the construction of the proposed system. Based on the above documentation, I have evaluated the structural capacity of the existing system to support the additional loads imposed by the solar panels arrays and offer the following comments. The solar panel mounting system is a LFlronridge XR100. The existing roof type is standing seam steel roof(single layer). Roof and solar system framing is shown on Sheets PV-3 and PV-4. Structural Analysis: The structural analysis has been carried out using the following design criteria: Design wind speed: 130 mph Ground snow load: 20 lbs./sq. ft. Solar Array, dead load: 2.9 lbs./sq.#t. Solar Array, Total Weight: 3844.5 lbs. The above values are within acceptable limits of recognized standards for similar structures. The structural analysis performed for the existing structure and for the solar panel arrays utilizing the above design loads, indicates that the existing roof rafters will be able to support the additional weight without damage if installed correctly. The onsite inspection and the photographs show that the roof framing is in good conditions. However, the dwelling owners are to be made aware that long term buildup of heavy snow conditions may produce deflection in the roof structure. If any deflection is noticed, then it is recommended that the solar panels be cleared of accumulated snow more than one(1)foot deep over a period of one week if no deflections are visible under any snow loading over a period of time, then there is no need to clear the solar panels. Based on the above evaluation, it is the opinion of the undersigned professional engineer,that with appropriate solar panel anchors being utilized, the roof system will adequately support the additional loading imposed by the solar panel arrays. This evaluation is in conformance with the NYS 2020 Building Code, ASCE 7-16"Minimum Design Loads for Buildings and Other Structures",cement industry standards and practice and based on documentation and data supplied by E2Sys at the time of this report. Should you have any questions regarding the above or if you require additional information, do not hesitate to contact me. Sincerely, of NEJy )o o.SCIA J v lC0 060935'� O AROFESSIONW Sincerely, Luigi Claudio Sciandra, Professional Engineer. powered by ,_IMW X1� .�"erg, �::�:�:.�• ;:�=�°,�-es�-c � 1A41t1tStt41�1"i - _ w" = ``tt{ik1t9111114At1 ''s .• ;:-r• _".:".,� ,,fix •• ,��� a 2 Quality . • , : Controlled PV • , TUVRheiniand ' wwwAuv.com ID 1111232615 . • (+3 • /b.._70P BRAND.P,V., EUROrE 2021 0 CELLS Yield Security BIFACIAL ENERGY YIELD GAIN OF UP TO 20 IL�JI"II Bifacial Q.ANTUM solar cells with zero gap cell layout make efficient use of light shining on the module rear-side for radically improved LCOE. LOW ELECTRICITY GENERATION COSTS Q.ANTUM DUO Z combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology for higher yield per surface area,lower BOS costs,higher power classes,and an efficiency rate of up to 21.4%. INNOVATIVE ALL-WEATHER TECHNOLOGY ��; Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE �.- Long-term yield security with Anti LID and Anti PID Technology', t Hot-Spot Protect and Traceable Quality Tra.QTM. i FRAME FOR VERSATILE MOUNTING OPTIONS r :;•' High-tech aluminum alloy frame protects from damage,enables use of a wide range of mounting structures and is certified regarding IEC for high snow(5400 Pa)and wind loads(2400 Pa). G A RELIABLE INVESTMENT Double glass module design enables extended lifetime with 12-year product warranty and improved 30-year performance warranty2. e BUSBAR 12 BUSBAR CELLTECHNOLOGY CELLTECHNOLOGY APT test conditions according to IEC/TS 62804-1:2015 method B(-1500 V,168 h)including post treatment according to IEC 61215-1-1 Ed.2.0(CD) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Ground-mounted AN solar power plants Engineered in Germany OCELLS MECHANICAL SPECIFICATION Format 87.2 in x 41.1 in x 1.38 in(including frame) (2216 mm x 1045 mm x 35 mm) s,•,c,, , Weight 64.2lbs(29.1kg) Front Cover 0.08 in(2.0 mm)thermally pre-stressed glass with °.• �. a anti-reflection technology 00 °u•°=.=�sue° Back Cover 0.08 in(2.0 mm)semi-tempered glass Frame Anodized aluminum Cell 6 x 26 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes Cable 4mm2 Solar cable;(+)>_27.6in(700mm),(-)a13.81n(350mm) Connector Staubli MC4,Staubli MC4-Evo2,Hanwha Q CELLS HQC4,IP68 °armmmµII°=''°` °.°wms°oimecma ELECTRICAL CHARACTERISTICS POWER CLASS 475 480 485 490 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'AND BSTC'(POWER TOLERANCE+5 W/-0 W) BSTC° BSTC° BSTC° BSTC• Power at MPP' PMPP [W] 475 519.6 480 525.0 485 530.5 490 536.0 E Short Circuit Current' Isc [A] 11.08 12.12 11.12 12.17 11.16 12.21 11.20 12.26 E Open Circuit Voltage' Voc IV] 53.15 53.34 53.39 53.58 53.63 53.82 53.86 54.06 c Current at MPP iMpp [A] 10.55 11.54 10.59 11.58 10.63 11.63 10.67 11.67 Voltage at MPP VMpp IV] 45.03 45.02 45.33 45.32 45.63 45.62 45.93 45.92 Efficiency' q [%] >_20.5 222.4 >_20.7 >:22.7 >_20.9 >_22.9 >_21.2 >_23.1 Bifaciality of PMpp and Isc 70%±5%•Bifaciality given for rear side irradiation on top of STC(front side)•According to IEC 60904-1-2 'Measurement tolerances PMpp±3%;Isc,Voc±5%at STC:1000 W/mz;*at BSTC:1000 W/m'+9 x 135 W/m',9=70%±5%,25±2°C,AM 1.5 according to IEC 60904-3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOTz Power at MPP PMPP [W] 357.6 361.4 365.1 368.9 E Short Circuit Current Isc [A] 8.92 8.96 8.99 9.02 E Open Circuit Voltage Voc IV] 50.27 50.49 50.72 50.95 c Current at MPP iMpp [A] 8.30 8.34 8.37 8.40 Voltage at MPP VMPP IV] 43.06 43.35 43.63 43.92 2800W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE .a 110 �?? -UsAt least 98%of nominal power a W C°e IwzryuaNaNM M>xs+amei V I I I I I • • MN.°YWMW i°«.°wm.",,; during first year.Thereafter max. B° 0.45%degradation per year.At least r)Lao --I------ a w` 93.95%of nominal power up tol0 E zl years.At least 84.95%of nominal i o opower up to30years. t= so --r-----r-----r-----r----------- Q All data within measurement toleranc-es.Full warranties in accordance with B0 zoo aao eoo soo i000 uoo e the warranty terms of the Q CELLS IRRADIANCE(AI/m+] m ,s sales organisation of your respective v e ro u xo °e country. 1° y°y narywmw�pro YEARS Typical module performance under low Irradiance conditions in vl comparison to STC conditions(25°C,1000 W/mz) m TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Voc p [%/K] -0.27 X 0 Temperature Coefficient of PMPP y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 108±5.4(42±3°C) o a w PROPERTIES FOR SYSTEM DESIGN a N Maximum System Voltage Vsys IV] 1500 PV module classification Class II Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 294 0 Max.Design Load,Push/Pulls [Ibs/ftz] 75(3600Pa)/33(1600Pa) Permitted Module Temperature -40°Fupto+185°F m Max.Test Load,Push/Pull' [Ibs/ftz] 113(5400 Pa)/50(2400 Pa) on Continuous Duty (-40°C up to+85°C) k u 'See Installation Manual 4 New Type is similar to Type 3 but with metallic frame - u QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION ° m Duality Controlled PV- Ib al-1 Taft IN Rheinland; w O-O 140IHCI vo IEC 61730,215CE-compliant, �® L/��. lecslzls.2ols, ruvnne'w°s Horizontal 89.4in 43.1in 476in 1975lbs 20 20 29 - IEC6atent o.9 C'ccron°a us packs in 2270mm 1095mm 1210mm 896k a U.S.Patent No.9,893,215 UL 61,3° packaging 9 pallets pallets modules ti (solar cells) 1°iIII..2zn Vertical 90.8ln 45.3in 47.4in 2013lbs 20 20 30 packaging 2306mm 1150mm 1205mm 913kg pallets pallets modules Note:Installation Instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwhe 0 CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiry@us.q-cells.com I WEB www.q-celis.us Single Phase Inverter Z • C with HD-Wave Technology m for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE10000H-US / SE1140OH-US m Optimized installation with HD-Wave technology ® Specifically designed to work with ® Extremely small power optimizers ® Record-breaking efficiency ® Built-in module-level monitoring ® Fixed voltage inverter for longer strings ® Outdoor and indoor installation ®. Integrated arc fault protection and rapid shutdown for ® Optional: Revenue grade data,ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) ® UL1741 SA certified,for CPUC Rule 21 grid compliance solaredge.com solar=@9 / Single Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 ( 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.50) Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output _ 16 - 24 48.5 A Current @208V GFDI Threshold 1 A Utility Monitoring,Islanding Protection,Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 1 15500 1 17650 W Maximum DC Power @208V - 5100 7750 - 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VR1 8.5 10.5 13.5 16.5 20 1 27 30.5 Adc Maximum Input Current @208Vm - 9 13.5 - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional") Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4'minimum/14-6 AWG 3/4'minimum/14-4 AWG DC Input AWG Range Conduit Size/#of Strings/ 3/4'minimum/1-2 strings/14-6 AWG 3/4'minimum/1-3 strings/14-6 AWG Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm Weight with Safety Switch 22110 1 25.1/11.4 1 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-25 to+60K(-40'F/-40°C option)() 'F/-C Protection Rating NEMA 4X(Inverter with Safety Switch) m For other regional settings please contact SolarEdge support m A higher current source may be used;the inverter will limit its input current to the values stated rn Revenue grade inverter P/N:SElo=H-US000NNC2 In For power de-rating information refer to:https://www.sclaredge.com/sites/defaulUfiles/se-temperature-derating-note-na.pdf R7-40 version P/N:SE=cxH-US000NNU4 m SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro H S other trademarks mentioned herein are trademarks of their respective owners.Date:1212018N01ANG NAM.Subject to change without notice. SCOPE Of WORK DMIGN d DRAFTING 13Y. ELEMENT ENERGY LLC TO INSTALL A 25.705 KWDC 50L.AR PHOTOVOLTAIC(M 5Y5TEM AT PECONIC WATER 5PORT5. MIEW 13Y J.M.NAI3CEP CtMRTllFlE v 051112-129 LOCATED AT 4G770 COUNTRY ROAD 45,50UTHOLD,14Y 1 197 1. ssrxp THE POWER GENERATED BY THE FV 5Y5TEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE 73 P, EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS D -PdPnON t5L DATE rFEV 5-06-20241 SYSTEM RATING 25.705 kW DC 5TC Eli) EQUIPMENT SUMMARY Sh~ISIM 53 QCELL Q-PEAK DUO XL-G I 0-3fl3FG 485 WATT PV MODULES 53 50LAPZDGE 55005 POWER OPTIMIZERS 2 r A 50LAREDGE 5E I 0000H-U5 INVEPTER5 IRONRIDGE XR 100 MOUNTING SYSTEM Pecak I ag� CONTRACTOR ELEMENT ENERGY, LLC SKEET INDEX 7470 SOUND AVE PV -I COVER MATTITLICK, NY 1 195 PV-2 511TE MAN \PROJECT LOCATION LICENSE# 674G I-HI PV-3 ROOF PV LAYOUT I LICENSE# 52G89-ME PV11 5TRUCTURAU DETAIL54 5ECTI0N5 PV-5 3-UNE ELECTRICAL DIAGRAM PV-G LABELS GOVERNING CODES 2017 NATIONAL ELECTRICAL CODE. 2020 BUILDING CODE Of NEW PORK STATE. Illa 2020 FIRE CODE OF NEW YORK STATE. A5CE 7-1 IG AND NFPA-70. UNDERWRITERS LABORATORIES(UU 5TANDARD5 05HA 29 CFR 1910.2G9 GENERAL NOTES FFOJ,CF NAME ILI 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT 0 co u- THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE to- — HIMSELF WITH THE INTENT Of THESE PLANS AND MAKE WORK uj AGREE THE SAME. AERIAL VIEW 1-- 0 (L 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, PERMITS,CERTIFICATES OF OCCUPANCY, INSPECTION APPROVALS, ETC.. FOP,WORK PERFORMED FROM 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP lu CO1dTIRACTOK5 LIABILITY,WORKMAN5 COMPENSATION, AGENCIES HAVING JURISDICTION THEREOF,IF REQUIRED. 0 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION,ETC.ADEQUATE FOR THE PURPOSES (o C-) 0 0 OF TH15 PROJECT AND FURNISH PROOF Of SAME PRIOR TO 0 — (-) r- ALL RULES AND REGULATIONS Of THE RESPONSIBLE tu z COMMENCING WITH WORK. 0 JURISDICTION. 0 0 1" 0 0 u rl- 0) 4. If IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS 11. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FORn lu WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE THE-CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS ENGINEER. SHOULD HE FAIL TO FOLLOW TH15 PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION.TH15 SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE A14D PROPER BRACING, 5HFET NAME 5. ALL 5TRUMRAL STEEL SHALL BE A-3G AND SHALL BE SAFETY IRAIUNG5 AND SECURE FOOTINGS FOR.ALL TEMPORARY FABRICATED AND INSTALLED AS PER LATEST A.1.5.0 SCAFFOLDING, STAIRS, ETC..AS WELL AS PERMANENT SPECIFICATIONS. CONSTRUCTION. COVER G. ALL ELECTRICAL WORK SHALL BE BOARD Of FIRE 12. FIGURED DIMEN51ON5 SHALL GOVERN. DO NOT SCALE UNDERWRITERS APPROVE[)AND IN ACCORDANCE WITH N.E-C. 4. DRAWINGS,WHERE DIMENSIONS ARE E5TABU5HED BY EXISTING NY5 CODES 4 REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 7.ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND CONSENT Of THE ENGINEER WILL NEGATE THE ENGINEERS COMMENCING WITH WORK. DRAWING SCALE CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY TH15 5.THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE Of IN A LEGAL MANNER ON N .T.5. SHALL REMAIN THE PROPERTY Of THE ENGINEER WHETHER THE A WEEKLY BASIS OR SOONER If CONDITIONS WARRANT. PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK,THE 51TE TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR Of ALL DEBRIS AND EXCESS MATERIALS.THE FACILITY 15 TO BE EXTENSIONS TO TH15 PROJECT LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE 5HEET NUMOEF 9. CONTRACTOR SHALL PROTECT,PATCH AND REPAIR ALL TOTAL 5AT15FACTION OF THE OWNER MOP,TO RELEASE OF EXISTING WORK ADJACENT TO H15 WORK,OR DAMAGED AS FINAL PAYMENT. L Fv- I RESULT Of HIS WORK. TAX MAP: 1000-055.00-05.00-009.001 LEGEND ' DESIGN a DRAFTING BY: �f7fIS11NG UTILITY METER ELEMENT IJ Y LLC MAIN SERVICE PANEL NEW PV SUB—PANES REVIEW�"051 1 I�9 CERTIFIE A/C DISCONNECT COMM INVERTERS NER REVISIONS ram.+ GND ELECTRODE 0 OfSCnIPf10N DATE REV ®PV MODULE I _ORIGINAL 0S-06-2024{{1 —RACIGNG RAIL O ATTACHMENT POINT � ---RAPIERS 240o D 9p-F -*-ROOF POW ANGLE 210; 12p- ! BSUNRUN METER 1 1s0° 800 -r- ®� f OPLUMIING VENT / ! ®9CT LIGHT CONTRACTOR ®CHINKEY COMPOSITE�IXES /J ELEMENT ENERGY, LLC. GM CONDITION DVE 'i S I�>t59 r j%�f�/�j������ /��i / M 7470 SOUND AVE `J' ATTITUCK, NY 1195 f LICENSE# G74G I-HI LICENSE# 52G89-ME j / ff rA m GzEn 1 rip/ i� 75-11 ' ram/ n PROJECT NAME I ,>/ _ O co r OR 0 + V - iulf 'n En r ,u U) H O Q r u (� l/ rr D-r W Z Q v O O / w 0 O Z) in O / uJ to snits NAME SITE PLAN "NOTE 1). FIRE 5ETBACWATHWAY 15 PROVIDED IN ACCORDANCE WITH 2O20 NY5 FIRE CODE. w 2). GROUND ACCE55/PATHWAY5 PROVIDED IN ACCORDANCE WITH THE 2020 NYS FIRE CODE. W DRAWING SCALE 3). NO EXI5TING VENTILATION HATCHE5 ON THE ROOF 2 4). EXTERNAL ACCE551BLE PV 5HUTOFP SWITCH, SERVICE ENTRANCE AND PV INVERTER5 ARE LOCATED AT THE WE5T 51DE EXTERIOR WALL 2� ! G" 5). 5AFETY SIGNAGE ARE ATTACHED TO THE EQUIPMENT5 A5 PER NEC2017 �083 CON5TRUCTION NOTES A��fESS1�NP� 1.)ALL EQUIPMENT 5HALL BE IN5TALLED IN ACCORDANCE WITH THE SHEET NUMBER MANUFACTURER'5 IN5TALLATION IN5TRUGTI0N5- p� /_ 2.)ALL OUTDOOR EQUIPMENT 5HALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. I �/ 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1 000-055.00-05.00-003.00 1 LEGEND CONSTRUCTION SUMMARY CON5TRUCTION NOTES DESIGN a DRAFTING BY: �DOSMG UTILITY MOM (53)QCELL Q.PEAK DUO XL-G 10.3BFG 485 WATT PV MODULE5 1.)ALL EQUIPMENT 5HALL BE IN5TALLED IN ACCORDANCE ELEMENT ENERGY LLC MM�°CE PANEL (DIMENSIONS:87.24"X 4I.14"X I.38") WITH THE MANUFACTUREK5 INSTALLATION IN5TRUCTION5. REVIEW BY J.M.NABCEPCEP.TIFIE- � /PDI SUE)--PANELS s 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH A/C DISCONNECT (53)SOLAREDGE POWER OPTIMIZER 55008 os i I i 2-129 COMBFNER (9G)ATTACHMENT POINT5 @ 72"O.C. MAX. MINIMUM NEMA 3R RATING. RAMES � cNn�cTRaoE (3G7.5)LF IRONRIDGE XRI 00 MOUNTING SYSTEM. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE REVISIONS ROOF TYPE: STANDING SEAM 5TEEL ROOF(51NGLE LAYER) FIELD VERIFICATION_ DESCRIPTION DATE n ®PV MUGULE -- - -- — ORIGINAL OS-06-2024 —RACKING RAIL O Am mum PGPIT I r- ---RAFTERS I -4--RW PTR]i ANGLE BSUNRUN METER ®SKY EIGHT ®�� / COTdTRACTOR Im c CoNmTm / ELEMENT 7470 SOUND AVE C � �` AS ��GWE W-CESsA" y MATTITUCK, NY 1 195 UCEN5E#,G74G I-HI UCEN5E# 52G89-ME %%%///ram//// r ---------------------- I I j F PRDJECENAME ` 1 O TD tu m O En rn > of NEvv Yo9 U z O 'r yi 0 �Q cn U O O ivi I 1 i M Lu ~ > Z O Uj O C9 s OFs`O�Pv f SHEET NAME I ' PV LAYOUT IDRAWING SCALE ARR"X53 MODULES 5- W2,Q d I/I G" = 1 1-011 5" PITCH 240, �900 249' AZIMUTH D 29o0 1200 180015po 5HEET NUMBER s PV-3 TAX MAP: 1000-055.00-05.00-009.001 Fran®M.eeroaSN - Boa Cameabn 5 Plate StlieOule Frame armime - .. • Part Maa WiAar Tw* WabThXDgghl Dgda APPMX101 APP a W.Uhf Dated! 1° Oty G.W. Sch Boa Ptah Rowe Rowe PeMlo Haiz.Clearan®tune'ecn memtere llC%o01)and 10{C7(002x 7f-015n6' CX001 1 6=30 .SDOD .1644 11-3' 1'IT 2Z-0111116• 6&W aFa. LWggh Thick. Out Ln Hbrl2.Cba0ncebet.aenmembae l(CX001)an411(CX002r.74-0151TE DESIGN 4 DRAFTING BY: Y RBX001 2 S.0000 3750 .1345 7-1' 2-11 28�11116• saw A 4 A325 314' 21? 1rr 1 1 0097284 Val.Cbmmimatmembar l(CX0011.2P-35n6- 3 SW00 Ass .1.5 7-1 74- S 4 A32s 3/4- 212' 310' 1 1 a047284 vM Cleaai®atmrmber la(C%002j:IS-4013116- ELEMENT ENERGY LLG 000 4 5.0 .1875 .1345 7.1• 7-1' C 6 A325 374' 21rr 3tr 1 2 0397284 VaLCb aiae eatmaeber 12(EP=1):27-01311E REVIEW BY J.M.NABCEP CERTIFI R6X007 5 5DDDD .1875 .1345 7-1- 1'd 2V-10517E 450 D 8 A325 314• 21rr aw 1 a 0097284 Vot Clem wat mee�0Or 13(EPX011427.81? W 6 5m .1975 .1345 Tor 1'S 71,1E E 6 A325 314• 210 31E 2 1 0097284 Ftdowd Flea 0-tim=IW-0'(Urdeas Nota°Oth r ) 05 1 1 1 2-1 29 RBXD03 7 5D0a0 25DO .1345 1'S 11,1E 2-1' E-05HE 1280 F 4 A325 7R° 11? M. 1 1 49M 8 SDD00 2500 .1345 7-r 1'�7H' S>-MiNhg-(095ST2)nq'E in FWq.S ik SOw d y. RSXDD4 8 SD00D 25M .1345 1-0114- 1'-1E 18a 15,1E 4109 CX002 to 6DD00 2500 2m0 r.S 1'3' 15-1013,1E 3090 REVISION5 11 GD000 25M .1345 T3 11S' NOTE E'P)m01 12 60000 3750 .1875 T-r T2 27-1 iris 5700 BR75CA Q EP1(002 13 6.0030 3750 .1875 1.2 1'2 Me 778' 5990 BR25CA DENOTES LOCATE FBLC2l11P WITH PllRL04 LAP D15CRIPTION DATE REV OA ME22AN04E BEAM SIZE AND CONNECTIONS REFER PAGf:S7- HOLES AND FIELD DRILL 811E DIA.HOLES IN THE FLANGE OF ROLL COLLECTOR BEAM AND DOLT THROW ORIGINAL 05.0E-2024 PURLIN&BEAM FLANGE OR ROLLCOLLEC1'ORBEJNF CONNECTIONS REFER sm R5X003 (Y� ff NOT 115E SINGLE WBBC2 CLP(REFEIi f.'ED:L1R%004j CONTRACTOR Ci 3` ELEMENT ENERGY, LLC 6. 7470 50UND AVE 01 Q IMATTITUCK, NY 1 195 LICEN5E# G74G 1-111 LICENSE#52G89-ME o Y�9 C r us PROJECT NAME O �i 0 t� - tu J 1 (,,1 0) a tea• c - me 'Wl fa n a ' 0 Q z o En U O O U = ROOF FRAMING DETAIL I lu Oz O LOAD CALCULAnoN ARRAY A l O L) � O MODULE WEIGHT(Lb5) G4.2 2 D_ WIND DE51GN 5UBJECT TO DAMAGE FROM d9 OF MODULE5 53 GROUND 5E15MIC WINTER ICE BARRIER FLOOD AIR MEAN SNOW DESIGN Frost DESIGN UNDERIAYMENT IIAZARD59 FREEZING ANNUAL TOTAL MODULE WEIGHT(Lb5) 3402.E LOAD° 5pet Topographic 5pecial Wmdborne CATEGORY' TEMP` REQUIRED•' INDEXi TEMPS 5HEET NAME (mph) effects, xnnd region debris zone", Weatfienn41 line Termite` TOTAL LENGTH OF RAIL(Ft) 367.5 dept}t5 ' RAIL WEIGHT PER FOOT(Lb5) 0.65 20 140 NO NO NO B 5EVERE 3 FT MOD TO 15,F YE5 FEMA 599 51,F 5TRU CTU RAL Notes: � HEAVY ZONE X ► . TOTAL RAIL WEIGHT(Lbs) 245.9 MANUAL J DESIGN CRITERIA" 1. S-S-S 41 �2. #OF 5TRANDOFF5 96 Indoor 2. 0.9 3/8-24 T30 Drive SetSerew Winter 5ummer design heating temperature WEIGHT PEP, (Uri) 2 Elevation Latitude heating Cooling Altitude correction factor tempera Design temperature cooling difference DRAWING SCALE 3. M8-1.25 16 mm Bolt 4. Example roof TOTAL STANDOFF WEIGHT(Lbs) 152 titre TOTAL ARRAY WEIGHT(Lbs) 3844.5 105 FT 4 I,N 15,F 86,F 1.00 70°F 75'F 55,F A5 NOTED 4.� Wind Wind POINT LOAD(Lbs) 40.0 Cooling temperature d fference velocity velo t Coincident Daily range Winter Summer humidity _ wet b TOTAL ARRAY AREA(5q Ft) 1319.2 heating cooling bulb humidity SHEET NUMBER ARRAY DEAD LOAD(I -s Ft) 2.9 15,F 15 MPH 7.5 MPH 72,F MEDIUM(M) 40% 32 GR Q50%Rh PV- MOUNTING DETAIL !�1-TAX MAP: 1000-055.00-05.00-009.001 DE51GN 4 DRAFTING BY: ELEMENT ENERGY LLC P NEW �• REVIEW BY J.M.NABCEP CERTIFIE 051 1 12-129 100 Vv REVISIONS (N)EWARTE S(OTY 2-TOTAL) SOLAREDGE SE11000QWS00LBE15,240 VAC `� I.LI DESCRIPTION DATE REV 99%oECmWBGHTEDFFfICIENCY LLI 1 TO UMY GRID ORIGINAL 05-06-2024 NEMA 3R.TA LISTED.INTERNAL GFDI �, tZ. tGW PS83 ACCT GRID COMNEcnoN�547,RULEn RULE�S y Cr�UANT WITH 75H OF PSEG INTERCONNECTION GUI �= EXISTING UTILITY NO,L FREO.593 Hr.UA)C FREO.60b M 00 SONAR LOAD CUM 7RAN.4UaFR MAX sc�u 240 VA I-M 1 p p�9pg38� P�' 1 < T < LIL iE11A IStm A NEW 25.705 KWDC SOLAR PV SYSTEM v -•O`���` 210 (53)pOELL CU'EA1c DUO XL-Gt0.3BFG 4&5 PV PANGS will, N 1 '(53)SOLAREDGE SSDOB POWH2 o A UT{liY 1EIERUPA EQUIPMENT (z)SOLAR®GESEtODDWi1151NVERTHts 1 MER f10 z40 v (CONNECTION TO WFJ1iHER IffAD� AND THE METER) JA aCONTRACTOR 1 2 •• 13 1 2 • 1411 NALmaell icc _ / _ _- ---- --- - I1111. a X40A ELEMENT ENERGY, LLC. I STPoAY2 1 ( 7470 SOUND AVE MVERTEFW SEIGOOM-Ls HOME WAVE INVERTER G t EXTERNAL Umm DISCONNECT SW7W DEVELOPER EQUIPMENT MATTITUCK, NY 1 195 (1)WMG OF(13)S5= 2cDMCGW T-UMITY AC�LE (CONNECTION FROM WEATHER HEAD)(1)S7M(;OF(14) ^ � - 70 BE��ON UCEN5E#G74G I-HI - j ��- - ( EXTERIOR WALL OF TINE BUILDING LLE scat lo,®.� LICENSE# 52689-ME t sowar=A G G - N i i �� 7m�liffi"C1m 10C 05�WM 1 I I mA I I I 1 1 I I ( 1 2 •• 13 1 2 •• 13 - 1 1 NNNRau1ID t • 1 1 ;u�� N----- - - - ------------ __ --- - MAIN SERWM PANEL HY OTHERS SDI 3 SIRIM 4 1 1 I-11n" INVf IMP SEi000DH-US HOME WAVE MWOM G G r 4M A (2)STMNGS OF(13)S5008 1 "E^'"•c SYSTEM 1 I 1 I 1 4>EC.•Tf101E3)NO3 iL Low PROJECr NAME WIRE CONDUIT 5CHEDULE 0 O � CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND- TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(°h p I.D.+� ORIGIN DESTINATION 51ZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION - (CU/AL) TYPE 51ZE TEMP DERATE D15TANCE U Q 310.ISBX3) 310.15(BX2ay(3c) LD IL O V Wire STRING INVERTER AWG#8 1 8 0.7 U5E-2/Pre AWG#8 1 BARE CU FREE AIR I' 559C 0.84 20O FT 1.45% r 0) 2 O OR RMC W ( Z 2 INVERTERS LOAD CENTER AWG#4 1 6 0.8 THWN-2 AWG#8 1 THWN-2 CU PVC I° 450C 0.95 50 FT 0.78% g Q Z 3LOAD D1 C:NECII I AWG#I I ! 6 I THWN-2 AWG#6 I THWN-2 CU PVC 1-1/4' 45aC 0.95 30 FT 0.52% O O-1 N O O- O U (L a ELECTRICAL NOTES 1.)ALL EQUIPMENT TO BE U5TED BY UL OR OTHER NRTL,AND LABELED FOR ITS AFMCATION. 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOD V AND 90QC WET ENVIRONMENT. 5HEET NAME 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHAD.BE ROUTED DIRECTLY CALCULATIONS FOR CURRENT CARRYING CONDUCTORS TO,AND LOCATED AS CL05E AS P0551BLE TO THE NEAREST RIDGE,HIP,OR VALLEY. CONFIGURATION vsrxvoLTAGeTwrsErnlx 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL #I PV Source Circuit Wire Ampacity Calculation s 3-LINE D I A. COMPLY WITH NEC 1 10.26. [NEC 690.8(B)(I)I:(Isc)'(#of stnng5)'(1.56)= 22.5 A Modules per 5tnng 24 MAX. VOLTAGE RANGE(S Or BASE QZAFJNG T1W isEg GAIRINGTIIN$(Ci'CLt5) 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL AWG#8,ampaaty'Temp Derate=23.1 A `'OLTAGFJ FURNISH ALL NECE55ARY OUTLETS,SUPPORTS,FfMNG5 AND ACE550RIE5 TO FULFILL 23.1 A>22.5 A,therefore DC wire sae Is valid. Modules per Inverter 140 MAX. v s so 1.1 66 APPLICABLE CODES AND STANDARDS. #2 Inverter Output Wire Ampacity Calculation Number of Inverters 2 V s so so 300 G.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, Inverter Max Amperage output'(1.25)= 174.375 A Record low temp -I()QC V z tic 2.0 120 THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 2/O AWG,ampaaty'(remp Derate)'(Conduit Fill Derate)= 187.2 A Voc TempCoefficient -0.24%/QC DRAWING 5CALE 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 187.2 A> 174.375A,therefore AC wire size Is valid. DC SYSTEM SPECIFICATIONS V a 120 O.IG 9.6 8.)MODULE GROUNDING CUPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE #3S4 Inverter Wire Am as Calculation SUPPORT RAIL,PER THE GROUNDING CUP MANUFACTURER'S INSTRUCTION. P ty Operatinal Current 10.6 A TMCAI rREcuENCYM?5EMNG5 N .T.5. Inverter Max Amperage output'(1.25)=348.75 A Operating Voltage 4563 V 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEK WG 400 KCMIL,ampacNty'(Temp Derate)'(Conduit Fill Derate)=364-8 A . r,,Jwn m,,oO CLEARING TIME MCI QAMNG nMC ICYCE9) OR ILSCO GBL 4DBT LAY-IN WG- 364.8 A>345.75 A,therefore AC wire size is valid. Max-System Voltage 704.4 V i s s6.s 0.16 9.6 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) Short Circuit Current 14.0 A OR AG SYSTEM SPECIFICATIONS N s se.s Sao ItxA70 5HEET NUMBER 1 C.)THE DC 51DE OF THE PV 5Y5TEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. i x 6i.z soo iewoG 1 1.)INTERCONNECTION METHOD WITH P5EG GRID AND EQUIPMENT SPECS ARE IN ACCORDANCE Max AC Output Current 279 A PV-5 WITH THE P5EGU INTERCONNECTION GUIDE. O eraGn AC Volta a 208 V 1z6z.o 0.16 9.6 12.)FOR UNDER-AND OVER-VOLTAGE TRIP SETTINGS AND UNDER-AND OVER-FREQUENCY TRIP TAX MAP: 1000-05 5.00-05.00-009.001 SETTINGS FOR THE INVERTER USED MEET5 IEEE 1547 STANDARDS. SERVICE METER (D O INSTALLATION NOTE D ELEMENT ENERGYLLG REVIEW BY J.M.NABCEP GERTIFIE ® � SOLAR WSYSTEM PHOTOVOLTAIC • • • • ( 1 ) ALL LABEL SHALL BE INSTALLED IN 051112-129 EOUIPPEDWITH 950LARBREAICERJIG ACCORDANCE WITH THE 2017 NEC RAPIDSHUTDOWN ® O D REQUIREMENTS. _�P�n fioNs 1 ,' DL7Ji1Dtd DATE REV (2) ALL LOCATIONS ARE APPROXIMATE AND ORJGIIdAL i 05-06-2o 1 MLAX SYSTEM VOLTAGE VDC SOLAR AC LOAD CENTER- OUTSIDEDD NOT RELOCATE �. CURREN REQUIRE FIELD VERIFICATION. -- •OVMRRM I)= (3) LABELS, WARNING(5) AND MARKING -- ' I 03 SHALL BE IN ACCORDANCE WITH NEC -- TURNFLARD SHUTDOWN SWITCH TO O 1 TIE`OFF POSITION TO SHUT MvN . _ — . 1 10.2 1 (B). >nrsrsialmDREDUCE — ' SNmWaRDINTHEArdlAY AC DISCONNECT �ro„=A W� (4) THE MATERIAL U5ED FOR MARKING — `•`•'�`�" ��MM"®�" MUST BE WEATHER RESISTANT IN I � �mcEs SOLAR AC LOAD CENTER- INSIDE 2 � co1frRAaoR "" COMPLIANCE WITH NEC 1 10.2 1 (13)(3). 1�[; WtMfAV116E ELEMENT ENERGY, LLC. (5) THE PV SYSTEM CIRCUIT CONDUCTORS 7470 SOUND AVE DUAL POWER SUPPLY SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 195 SOURCES TOIALRATINGOFAI L -— - OVERCURRENTOE 0IM VXES.EXCLUG SOURCES:UTTLITYGRID • COMPLIANCE WITH NEC G90.3 1 . LICENSE# 6746 I—HI UCENSE# 52689-ME &MSUPALYOVERCURRENT AND PV SOLAR DEVICE,SHALL NOT EXCEED ELECTRIC SYSTEM CONDUIT- IN51DE BUILDING �'4Cfn'onu d - "CO=M131NE:R�PANNE:Lj } —; I S! TF S SERVICE METER ISALSOSERVEDBYA ELECTRICSHCSWaAM PHOTOVOLTAICSYSTEM PHOTOVOLTAIC SYSTEM TETi3M.LSONTHELINEAND I LOFS3 SOES!!AY BE ETiORGLZtrD i DO NOT ADD LOADS CONDUIT-OUT5IDE 1UILDING i --INTii=_O'�WPD�TIDy PROJECT NAME 1 - u- co (n DUAL POWER SUPPLY ISOU :RCES UTiLfTY GRID AND c ® H O O m PV SOLAR ELECTRIC SYSTEM` } — MAIN SERVICE PANEL- OUTSIDE 1 °A-CA(MON:501ARC1RWiTJ w D}c z O 0 J O O3 OS AGAUTIQN :, `" u O O SOLAR E ECTRICSYSTEMCCICEL®t ® z o lu O O © • • i O w r U) MAIN SERVICE PANEL- INSIDE �RUN � . . . • urs POWER SOURCE 1 j OUTPUT CONNECTION ® O ` DO NOT RELOCATE THIS G �O SHEET NAME OVERCURREN7 DEVICE LAB E L5 AC DI5CONNECT/13REAKER _ DRANING SCALE f 0 0 0 ® ® F ososa�°� N .T.5. �PROFISr%� 5HEET NUM13EP. PV-G TAX MAP: 1000-055.00-05.00-009.001