Loading...
HomeMy WebLinkAbout51177-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51177 Date: 09/12/2024 Permission is hereby granted to: John Rosko 129 Potato Field Ln Southampton, NY 11968 To: legalize"as built" alterations to an existing commercial building with sanitary certification. Additional certification may be required. Premises Located at: 2745 Peconic Ln, Peconic, NY 11958 SCTM#74.-5-9.2 Pursuant to application dated 06/02/2023 and approved by the Building Inspector. To expire on 03/12/2026. Contractors: Required Inspections: Fees: NEW COMMERCIAL ALTERATION OR ADDITIONS $1,425.00 CERTIFICATE OF OCCUPANCY $100.00 Total $1,525.00 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone 631 765-1802 Fax 631 765-9502 littos://Nvww.soLitliotdtownny.gov Date Received APPLICATION FOR BUILDI�NG PERMIT For Office Use Only � �--�•� "� � Building Inspector. PERMIT NO., JIM 2 . Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. " Date: OWNER(S)OF PROPERTY: Name: - LL SCTM#1000- G &sZa7 oZ Project Address� � d /✓"' -r = Zi9 • .r Phone#: Email:V ds,"d i� Mailing Address:/G--LT /0 o�^'E �v % ,"" ' CONTACT PERSON: Name: Mailing Address:" d Phone#: - ��d ��� Email: lclw_� " ✓�t DESIGN PROFESSIONAL INFORMATION: Name:✓j/p�v� Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION E]NewStructure ❑A" ditl n ❑A,(teration []Repair ❑De �Dlition Estimated Cost �Othev. r�+S ✓ r �. $ Will the lot be re-graded? ❑Yes f `No Will excess fill be removed from premises? ❑Yes-�Ao 1 PROPERTY INFORMATION si r l' Existing use of property: s' d�f.. y` r.Intended use of property: �a o�.w6/l Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to �. / _ this property? ❑Yes, ,o IF YES, PROVIDE A COPY. he::;*Box Atil.er Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): ❑Authorized Agent Owner Signature of Applicant: --' Date: STATE OF NEW YORK) Ss- COUNTY OF �1 e VQ K' 0 being duly sworn, deposes and says that(s he s the applicant (Name of individual signing contract) above named, (S is the e . (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file there "th m ,Sworn fore me this ,..,�. day of D N to P tic' Nobly Putrl" kA.Sa of `�OFk 507 PROPEL ) W 1I i . 1a Where the applicant is not the Jan.6' ( pp �e owner) [, residing at, do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 BUILDING DEPARTMENT-Electrl I epp " 2024 TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - F'(0 arnent Southold, New York 11971-0959TO n of"Southold w , Telephone (631) 765-1802 - FAX(631) 765-9502 ro err outholdt w n . Gov— seand@sQutholdiMnny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Custom Lighting of Suffolk Inc Electrician's Name: Benjamin Doroski License No.: 38893-ME Elec. email: Clos5170@gmail.com Elec. Phone No: 631-298-4588 211 request an email copy of Certificate of Compliance Elec. Address.: PO Box 1698 Mattituck NY 11952 ,JOB SITE INFORMATION (All Information Required) Name: 0. Address: C O n i c Cross Street: Phone No.: c Co. ' BIdg.Permit#: <. email: Tax Map District: 1000 Section: Block: Lot• BRI F DESC RIPTION OF WORK, INCLUDE SQUA , FOOTAGE ( lease Print Clearly), S uare Foota e: Circle All ThatApply: Is job ready for inspection?: . YES NO ❑Rough In ❑ 1:1 Final Do you need a Temp Certificate?: ❑ YES �NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 2 0 H Frame Pole Work done on Service? My N Additional Information: PA MEhIT DUE WITH APPLICATIQN, �� Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck,New York 11952 Fax 631-298-2651 www.condonengineering.com August 5, 2024 Mr. Mike Verity Building Department Town of Southold Town Mall P.O. Box 1179 Southold, NY 11971-0959 Re: Septic leer-2745 Peconic Lane,Peconlc,NY SCTM: 000-7 -5-9.2 Dear Mr. Verity: As requested, I reviewed the existing septic system at the above referenced property on July 16, 2024. My inspection found three 8-foot diameter x 9' deep precast cesspools accommodating the sewage flow from the bathrooms at the premises. There is another sewage disposal system on the property that is the laundry process water. Based on my observations and to the best of my knowledge, the existing cesspools were functioning at the time of inspection and appear to be in acceptable condition. Please call me if you have any questions or require additional information. You uly, = o m J. Condon, P.E. g ' Y w _ Kry w U/— ( SASS 1 I ri e ect c panel WDW304G♦ t12 _ I t egress window by 2°68 r — -� N in , Andersen or equivalent I I 0 access = I t > L---A ------ ------ BEDROOM # I o m �� �„ 3 o cm fn fa I n toll TYPE 13 5PRI N KLE5 oil l o proposed to s 2"G E I Q)7 throua hout the buildin on the _ 2468 �I 9 c� � ' �10 I i remove the existing door and fill Q ' U I I the gap until the header with 2x4 First and Second Floors and 15R'sDw 8• ° ' ' •@ stud at 16 �caand)Z n heetrock. BEDROOM # 2 Basement I T-'o APARTMENT 1328 SF I — — proposed removing partition walls — STORAGE - - -- - O r S proposed to Install = ` ONE-HOUR FIRE RATED (type X) 5HETROCK ____ []DTOILET 2068 II on the walls to the Second Floor I KITCHEN I I N Ceiling High 2 6 7'1 1' I 16' proposed to Install I BATHROOM i io BEDROOM # 3 ONE-HOUR FIRE RATED (type X) 5HETROCK oegress window by on the cellin s se aration between the Cellar and o tit�� S�k , , Andersen or equivalent 9 p I WDW304G♦ I the First Floor and the First Floor and Second I I proposed BUILDING SECOND FLOOR plan Floor and the Second Floor Ceiling 2x4 Studs Fire Stopped 16" glass brick window "Thick Fire Rated Gypsum Board I I heater Z M 1. Nail heads-Exposed or covered with joint compound. sJ: N ❑ a 2. Joints-Exposed or covered with fiber tape and joint compound. 3. Wall board nailed 7"OC with 6d cement coated nails 1-7/8"long,0.0915 shank diam,1/4"diam heads. 0 N i 4. Wallboard,Gypsum-5/8"thick Sheetrock EcoSmart Gypsum(UL Type ULIX)Panels attached to studs with the 1-7/8"long nails spaced 7"OC. CLOSET BATHROOM BATHROOM 2468 I 1 Hour Wall Detail 2668 e I UL Design No_U305 f I — — ----------- ------- — Ceding High � � I 8'-6' 2 6 Cie 2x10 Joists Fire Stopped (2)DRYER5 CL05ET up* down —— STORAGE (2)DRYER5 — — 927 5F Iup t- down STORAGE STORE I (2)DRYER5 WASHER WASHER WASHER WASHER WASHER WASHER WASHER — — ——— ——— /8"Thick Fire Rated Gypsum Board up* down 3' 1 O" ceiling high I 1_ Nail heads-Exposed or covered with joint compound. yps CLOSET � g g 1 po 8' O' 2. Joints-Exposed or covered with fiber tape and joint compound. ' . (�)� 5 3_ Ceiling board nailed 7"OC with 6d cement coated naffs 1 7/8"king,0.0915 shank diam,1/4"diam heads. p — — 3'-2. N 2468 I 4. Ceiling board,Gypsum-5/8"thick Sheetrodc EcoSmart Gypsum(UL Type ULIX)Panels attached to joists with WA5HER WASHER WASHER WASHER WASHER WASHER WASHER — — the 1-7/8"kxg nails spaced 7"OC. (2)DRown slokp --el ctric --- t� — up�down in , 7"concrete ,—— pane 3005 — — — platform �—— — C \5 eiling High 4 I 1 Hour Floor Detail (2)DRYERS 15R'sl1P@b" �n c9 ( UL Design No_U501 up*down T= 10" N kv ® CO �himn OWDER ROON POWDER (2)DRYERS STORE �n �' SECOND ACCESS to ground floor ROOM electric PORCH u up* down 676 SF N `'�� 2668 4 8 co panel ceding high 9'-9° electric EXIT electric JF2668 panel[ —————— panel 3°68 I I TABLE OF AREAS K_ 2 6 I safe O 3068 I E PR � � PROPOSED ROOM FIRST FLOOR 3G71 SF FRONT PORCH I P05T BOX CABINET I I I SECOND FLOOR 13G7 SF TOTAL GBA 5038 SF —" m 2468 m °' Q FIRST FLOOR % OF GBA o CUSTOMER I LAUNDROMAT G7G. SF 13.4 100 ------- SUPPLY STORE 921 . SF 18.5 ROOM 0 POST OFFICE m AREA 1015 SF P T o OS OFFICE 1015. SF 20. 1 2468 ceding high I VACANT COMMERCIAL SPACE 927. SF 18.9 new one hour fire-rated J_ TOTAL 3575 SF 1 70.9 self-closing insulated door SECOND FLOOR % OF GBA .,-- APARTMENT 1328. SF 2 '.0 ����OF co o smoke detector carbon monoxide detector I Hour Fire Rated Wall wood 5too <,..r. I' concrete 5too ELECTRIC METER �, I over concrete p enclosure I —` � �'� proposed BUILDING FIRST FL00*_l ��i scale: j411 I'I_Oil � ^ �