HomeMy WebLinkAbout51110-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 51110 Date: 8/21/2024
Permission is hereby granted to:
Wilson, Glen
4125 Sound Ave
Mattituck, NY 11952
To: Install a generator accessory to a single-family dwelling as applied for.
At premises located at:
4125 Sound Ave, Mattituck
SCTM # 473889
Sec/Block/Lot# 121.-1-1.4
Pursuant to application dated 7/9/2024 and approved by the Building Inspector..
p To expire on 2/20/2026.
Fees:
ACCESSORY $125.00
CERTIFICATE OF OCCUPANCY $100.00
ELECTRIC $100.00
Total: $325.00
_............ ..........
� _. _.. ..
Building Inspector
TOWN OF SOUTHOLD-BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 ://www outhol townn , ov
Date Received
APPLICATION FOR BUILDING PERMIT
E C E 0 V E
For Office Use Only
PERMIT NO. } 1 1 Building Inspector. '" JUL - 82024
Building Depart
�nent
Town Of Southold
r
Date:
r
Name: L� LSD SCTM # 1000- 1 21, b Cl
Project Address: L. f 2� S 60N Prv&NUC A44.51TI fUC- !�/ (I cl 52—
Phone#: 571& q dZ-Net 9 Email: (>LEN
Mailing Address:
';,CONTACT-PERSON:
Name:
Mailing Address:
Phone#: Email:
DCSiGN PROFE55f,ONAI iNF( RMATION;
Name:
Mailing Address:
Phone#: Email:
GpNTIgArCTC1�'II�F�RMATION; ;. , ".
Name; 4ra
Mailing Address: A JJV 111,j-r
Phone#:�S/ Email: -
,PESCRIPTIDIM OF,PROPq,SED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:.
Other ,a k0 $
Will the lot be re-graded? ❑Yes`4No Will excess fill be removed from premises? ❑Yes No
1
PROPERTY INFORMATION ''
Existing use of property: 5f1i�jtpje FAMI Ly Intended use of property: tW L-V
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
iiA,( lztr( I?w(At--,4&a.icuL4-uRAL-- this property? ❑Yes Nci IF YES, PROVIDE A COPY.
Check BOX After,Readirlg: The oWner/contractor/desigri professional is reiponsible for all drainage and storm water Issues as provided by,
Chapter 236 of the Town code.APPWCATION 15 HEREBY MADE to the Building,Department for the issuance of a Building Permit pursuant'to the Building zone
Ordinance of the lawn of Southold,Suffolk,'county,New Xgrk and,other applicable La+ivs,Ordinances or Regulat►ons,for the canstructian of bu►Idings,
additions,'alteratlons�or for removal or demolition ai herein describedr The applicant agrees to compiy with all,applicable laws,ordinances;buildrng code,
housing code and'rep'fa"tions end to-admit authorised fns66ctoh'on'premises and in buildings)for necessary Inspections.False statements made herein are
punishable as a classAmisdemeanor pursuant to Section 210.45 of the New York State penal Law.
Application Submitted By(print name): dAuthorized Agent El Owner
Signature of Applicant: Date: 71, 14;zo, ,,y
STATE OF NEW YORK)
COUNTY OF(-5 �I
being duly sworn, deposes and says that (s)he is the applicant
(Name f individual signing contract) above named,
(S)he is the
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith,
h
Sworn before me this q
r
day of � 20
µ,.
LORETTA LAMB
Notary Public.State of New York
PROPERTY OWNER AUTHORIZATION #01 IA6179883
(Where the applicant is not the owner) Ouatified In Suffolk Dounl
iiw0
Term Expires December'31,
'
I, ��'I v v ` residing at ` t2� Sb V I1q SZ
do hereby authorize A44^it., r to apply on
my b to e To V 7 A-7/0 h,of So hold Building Department for approval as described herein.
d, .
Owners Signature Date
Print Owner's Name
2
off BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
Town Hall Annex - 54375 Main Road - PO Box 1179
� Southold, New York 11971-0959
� Telephone (631) 765-1802 - FAX (631) 765-9502
smash southol'dtownn ov- seand southoldtownn ov
il
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (Au information Required) Date: ` L
Company Name:
Electrician's Name: 4
License No.: Elec. email:
Elec. Phone No: I request an email copy of Certificate of Compliance
Elec. Address.: �3
JOB SITE INFORMATION (All Information Required)
Name: � 1-5 o .
Address: it
Cross Street:
Phone No.: - - -(I g
Bldg.Permit #: email:
Tax Map District: 1000 Section: Block: Lot:
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
(-. o OO/A- 5-Zr v,C�A ra,L4
Square Footage:
Circle All That Apply:
Is job ready for inspection?: YES NO �Rough In El
Final
Do you need a Temp Certificate?: El YES DNO Issued On
Temp Information: (All information required)
Service Size Ell Ph 03 Ph Size: A # Meters Old Meter#
❑New service[:]Fire Reconnect[—]Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 1 2 0 H Frame Pole Work done on Service? El Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
\ E.SMITH
Z PE OWIN FENIX WE.
PE o.2 N
*A aO'S
O
N O
O
fTl O
r*1
Ya"o "
1 t
� Jr7
N/O/F of JOHN
SIMICICH PDMP
6 Io'E
SHED
14.1'
WW00D FEHGE D/L Tax Map
PE FOUND Lot 1.4 H=0
CONO•
?B.4'
OARAGE
PA"m N/O/F of
OWKWAY
E.SMITE
N
WOOD J
OCOK 0' m
N/O/F of DAVID R. IAA ms w I—smy
&JANE STARWOOD
eAZEDD
..2—sio R
Wa�I.S� A7
POND 4.4"
MANHOLE ..
v 3 3 '
0
PRE O
•
6
W
IrE PIER ,.�,.,„. ..
P. B.
"M/ , MGE OF PAYMENT 227.07
40
24„ 1 (DE `D) SB5°56'20"W
(ACr A ) SOUND AVENUE
�P 511IC� — Cam
GENERAC
20A2.4 kW GUARDIAN° SERIES _
Residential Standby Generators
Air-Cooled Gas Engine
Standby Power Rating 1 1
INCLUDES: G007038-1,G007039-1.3007038-3 G007039-3(Aluminum-Bisque)-20 MV 60 Hz
• True Power"'Electrical Technology G007042-10.0007042-11,0007043.10,0007043-11(Alumilim-Bisque)-22 I W 60 Hz
gy G007209-10.G0072'0-10 rAlumi*ium-Bisque)-24 W 60 Hz
• Two-line multilingual digital LCD Evolution"' controller
(English/Span ish/French/Portuguese)
• 200 amp service rated transfer switch available
• Electronic governor
• Standard Wi-Fi`�connectivity h`✓, ` ?' ,
• System status&maintenance interval LED indicators
• Sound attenuated enclosure
• Flexible fuel line connector
• Natural gas or LP gas operation n GENERAC
• 5 Year limited warranty
• Listed and labeled for installation as close as 18 in(457 mm)to a
structure,' ' a..
'Must be located away from doors,windows,and fresh air intakes and in
accordance with local codes. Product shown with optional fascia kit
Eta or Eo�s OU .
us uro�
Note:CEfL or CUL certification only applies to unbundled units and units ppackaged
with limited circuit switches.Units packaged with the Smart Switch are ETL or UL
certified in the USA only.
FEATURES
O INNOVATIVE ENGINE DESIGN A RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod-
Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI-
the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge
rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at+"1%.
O TRUE POWER'"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small-
allows confident operation of sensitive electronic equipment and micro-chip based est electronic component.
appliances,such as variable speed HVAC systems.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with
✓ PROTOTYPE TESTED ✓ NEMA M01-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system
compatibility.
O MOBILE LINK*-CONNECTIVITY:FREE with select Guardian Series Home standby
generators,Mobile Link Wi-Fi allows users to monitor generator status from any-
where in the world using a smartphone,tablet,or PC.Easily access information such
as the current operating status and maintenance alerts. Users can connect an
account to an authorized service dealer for fast,friendly,and proactive service.With
Mobile Link,users are taken care of before the next power outage.
GENERAC ® ;> @q
PROMISE E F
' 1
L
GENERAC'
20/22/24 kW Features and Benefits
_ Engine
• Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly
rings help the engine run cooler,reducing oil consumption and resulting in longer engine life.
• "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance These features combine to assure smooth,quick starling every time.
• Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine
life,Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown Prevents damage due to overheating.
Generator
• Revolving field Allows for a smaller,lightweight unit that operates 25%more efficiently than a revolving armature generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability,
• Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes.
• EPA Certified for non-emergency applications Allows unit to be used for demand response applications(excluding 20 kW units).
• UL 2200 listed For your safety.
Transfer Sviitch (if applicable)
• Fully automatic Transfers vital electrical loads to the energized source of power.
• NEMA 3R Can be installed inside or outside for maximum flexibility.
• Integrated load management technology Capability to manage additional loads for efficient power management.
• Remote mounting Mounts near an existing distribution panel for simple,low-cost installation.
Evolution"'Controls
• AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition.
• Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences.
• Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations,
• Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage.
• Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home.
• Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1.500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds.
• Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute.
• Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
• Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries,
• Main line circuit breaker Protects generator from overload.
• Electronic governor Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding
winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access
to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries.
• Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure.
E '
GENERAC'
mmommunn
20/22/24 kW Features and Benefits
Installation System _
• 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
• Integral sediment trap Meets IFGC and NFPA 54 installation requirements.
Connectivity(Wi-Fi equipped models only)
• Ability to view generator status Monitor generator with a smarlphone,tablet,or computer at any time via the Mobile Link application for
complete peace of mind.
• Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
• Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due.
• Monthly report with previous month's activity Detailed monthly reports provide historical generator information.
• Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
• Weather information Provides detailed local ambient weather conditions for generator location.
GENERACx
20/22/24 kW Specifications
Generator
Model G007038-1 0007042-10 GOOT038-3 G007042-11 GD07209-10
G007039-1 G007043-10 6007039.3 6007043-11 8007210.10
(20 kW) (22 kW) (20 kW) (22 kW) (24 kW)
Rated maximum continuous power capacity(LP) 20,000 Watts' 22,000 Watts' 20,000 Watts` 22,000 Watts' 24,000 Watts'
Rated maximum continuous Power capacity(NG) 18,000 Watts' 19,500 Walls' 18,000 Walls' 19,500 Watts' 21,000 Watts'
Rated voltage 240
Rated maximum continuous load current—240 volls(LP/NG) 83.3/75.0 91.7/81.3 83,3/75.0 91.7/81.3 100/87.5
' Total Harmonic Distortion Less than 5%
Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp
Phase 1
Number of rotor poles 2
Rated AC frequency 60 Hz
Power factor 1.0
Battery requirement(not Included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum
Unit weight(lb/kg) 446/203 466/211 436/198 446/202 455/206
Dimensions(L x W x H)in/cm 48 x 25 x 29 1121.9 x 63.5 x 73.7
Sound output in dB(A)at 23 II(7 m)with generator operating at normal load" 67 67 67 67 67
Sound output in dB(A)at 23 it(7 m)with generator in Quiet-Test"low-speed exercise mode" 55 57 55 57 57
Exercise duration 5 min
Engine
Engine type GENERAC G-Farce 1000 Series
Number of cylinders 2
Displacement 999 cc
Cylinder block Aluminum w/cast iron sleeve
Valve arrangement Overhead valve
Ignition system Solid-state w/magneto
Governor system Electronic
Compression ratio 9.5:1
Starter 12 VDC
Oil capacity including filter Approx.1.9 qt/1.8 L
Operating rpm 3,600
Fuel consumption
Natural gas iP/hr 2 Load Load 204(5.78) 228(6.46) 164(4.64) 203(5.75)
Full Ll Load 301(8.52) 327(9.26) 287(8.13) 306(8.66)
Ful
Liquid propane its/hr(gal/1/[Load 87(2,37)[8.99] 92(2.53)[9.57] 86(2,36)[8.95] 92(2.53)[9,57]
Full Load 130(3.55)(13.481 142(3.90)[14.77] 136(3,74)[14,151 142(3.90)[14.771
Note:Fuel pipe must he sized for lull load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP
gas.For BTU content multioly 113/nr x 2500(LP)or f0/hr x 1000(NG),For Megaioule content,multiply mslhf x 93.15(LP)or m3/hr x 37.26(NG).
Controls
Two-line plain text multilingual LCD Simple user interface for ease of operation.
Mode buttons:AUTO Automatic start on utility failure.Weekly,BI-weekly,or Monthly selectable exerciser.
MANUAL Start with starter control,unit slays on.If utility fails.transfer to load takes placo,
OFF Stops unit.Power is removed.Control and charger still operate.
Ready to RunflAainlenance messages Standard
Engine run hours indication Standard
Programmable start delay between 2-1500 seconds Standard(programmable by dealer only)
Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V
Future Set Capable Exerciser/Exercise Set Error warning Standard -
Run/Alarm/Mainlenance logs 50 events each
Engine start sequence Cyclic cranking 16 sec on,7 rest(90 sec maximum duration).
Starter lack-out Starter cannot re-engage until 5 sec after engine has slapped.
Smart Battery Charger Standard
Charger FauIVMissing AC warning Standard
Low Battery/Battery Problem Protection and Battery Condition indication Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Under-Frequency/Overload/Stepper Overcurrenl Protection Standard
Safety Fused/Fuse Problem Protection Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard
High Engine Temperature Shutdown Standard
Internal Faultnncorrect Wiring protection Standard
Common external fault capability Standard
Field upgradable firmware Standard
Rating definitions-Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed.No overload capability is available for this rating.
(All ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271).
Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude.engine power and condition,etc.Maximum power decreases
approximately 3.5 ro for each 1,0001t(304.8 m)above sea level,and also will decrease approximately 1%for each 10`F(6'C)above 60'F(1b'C).
"Sound levels are taken from the',ran!of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.
1 '
GENERAC°
20/22/24 kW Switch Options
Service Rated Automatic Transfer Switch Features G007039.1,G007039.3(20 kW)
• Intelligently manages up to four air conditioner loads with no additional hardware. Mosel G007043.10,G007043-11(22 kW) _
0007210.10(24 M
• Up to eight additional large(240 VAC)loads can be managed when used in conjunction No.of poles 2
with Smart Management Modules(SMNs). Current rating(amps) 200
• Electrically operated,mechanically-held contacts for fast,clean connections. Voltage rating(VAC) 120/240,10
• Main breakers are rated for 80%continuous load. Utility voltage monitor(fixed)'
-Pick-up 80% � 1
• 2-pole,250 VAC contactors. -Dropout 65%
• Service equipment rated,dual coil design. Return to Utility Approx.13 sec
ETL or UL lisled Standard
• Rated for both aluminum and copper conductors. Enclosure type NEMA(UL 3R
• Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000
• NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6
'Function of Evolution controller
Dimensions Exercise can be set to weekly,bl-weekly,or monthly
200 Amps 120/240,18
Open Transition Service Rated
Height Wtdth
H1 H2 W1 W2 Depth
in 26.8 30.1 10.5 13.5 6.9
cm 1 67.95 76.43 26.67 34.18 17.5 H2
Wire Ranges
Conductor Lug Neutral Lug Ground Lug
250 MGM-#6 350 MGM-#6 2/0-#14
cv,*� I—w2--t
GENERAC'
20/22/24 kW Available Accessories
_ Model# Product Description
G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(48 oC).(Not nec-
essary for use with AGM-style batteries),
G007102-0 Oil Warmer Oil warmer slips directly over the oil fitter.Recommended for use if temperature regularly falls below 0 IF(-18 IC).
G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where
heavy icing occurs.
' G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be
Contact Kit needed.Not compatible with 50 amp pre-wired switches.
G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators,This offers a sleek,contoured
appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base.
B005703.0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion.
The touch-up paint kit Includes the necessary paint to correctly maintain or touch up a generator enclosure.
G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a
Generac automatic standby generator(oil not included).
G007005-0 WI-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the
Monitor LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta-
tus alerts are available through a free application to notify users when the LP tank is in need of a refill.
G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.it manages large elec-
G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce
(100 amp) the overall size and cast of the system.
G007169.0.413 LTE Mobile LinkO Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using
G007170-0-WI-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us-
Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,
users are taken care of before the next power outage.
0007220-0-Bisque Base Plug Kit Base plugs snap into the fitting holes on the base of air-cooled home standby generators.This offers a sleek,contoured
appearance,as well as offers protection from rodents and Insects by covering the lifting holes located In the base.Kit
contains four plugs,sufficient for use on a single air-cooled home standby generator.
Dimensions & PCs
Model UPC 637.6 mm •218mm
125.1 in) [48.6 m]
G007038 696471074185
G007039 696471074192
G007042 696471074208
G007043 696471074215
0007209 696471071511 727.2 mm
[28.6 mt
G007210 696471084801 NMI
o O
If I 848 mm 1232 mm
f25.5Int [48.5 In;
LEFT SIDE VIEW FRONT VIEW
Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR II-STALLATION PURPOSES.
GENE RAC' Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com
C2022 Generac Power Systems,Inc.Ali rights reserved.All specifications are subject to change without notice.Part No.A0000937814 Rev.E 03,15/2022