Loading...
HomeMy WebLinkAbout50745-Z �o�OSUFFD1kcpG. Town of Southold 7/16/2024 a y , P.O.Box 1179 0 53095 Main Rd oy o�F Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45359 Date: 7/16/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 577 Pacific St,Mattituck SCTM#: 473889 Sec/Block/Lot: 141.4-14.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/17/2024 pursuant to which Building Permit No. 50745 dated 5/28/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to an existing single-family dwelling as applied for. The certificate is issued to Ciamaricone,Joseph&Janet of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50745 7/15/2024 PLUMBERS CERTIFICATION DATED 0 A or zed i nature �SUFFaI,r o TOWN OF SOUTHOLD ��o cry BUILDING DEPARTMENT N x TOWN CLERK'S OFFICE o��� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50745 Date: 5/28/2024 Permission is hereby granted to: Ciamaricone, Joseph PO BOX 1631 Mattituck, NY 11952 To: Install roof mounted solar panels to an existing single-family dwelling as applied for per manufacturers specifications. Additional certification may be required. At premises located at: 677 Pacific St, Mattituck SCTM #473889 Sec/Block/Lot# 141.4-14.1 Pursuant to application dated 4/17/2024 and approved by the Building Inspector. To expire on 11/27/2025. Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 ELECTRIC $125.00 Total: $325.00 Building Inspector oF so�jyol Town Hall Annex Telephone(631)765-1802 54375 Main Road CAP.O.Box 1179 Q Southold,NY 11971-0959 JameshCa�southoldtownny.gov OWN BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Janet Ciamaricone Address: 585 Pacific Street city:Mattituck st: New York zip: 11952 Building Permit#: 50745 Section: 141 Block: 4 Lot: 14.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: Element Energy LLC Electrician: Jamie Minnick License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200a Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200a A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 12KW roof mounted solar pv system with 30 modules Canadian solar-cs6r-400ms-hi 30 inverters enhase IQ8MC-72-M-us, 1 enhase cobiner panel, and 1 ac dissconnect fused Notes: SOLAR Inspector Signature: Date: July 15, 2024 585 pacific st / OF SOUIyo� TOWN OF SOUTHOLD BUILDING DEPT. °ycou►�,� 631-765-1802 � INSPECTION s . [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. ] FOUNDATION 2ND [ ]. I SULATION/CAULKING [ ]_ FRAMING/STRAPPING [ FINAL5�VjtV** [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ . ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR �aOF SOUIyo D 62p QC.J C �o �o # # TOWN OF.SOUTHOLD BUILDING DEPT. °yIOU 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ .] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY - [ ] FIRE SAFETY INSPECTION ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION f ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: >041 r DATE 7 INSPECTOR Current meals En- gineering Town of Southold An S)\%44, 2024 1 9 ent Subject: Post Installation Approval Letter 'Bo �° Job Name: Ciamaricone Residence 1614%\ Project Address:-56"acific St, Mattituck, NY 11952 5T7 To Town of Southold: I have reviewed the solar energy system installation in the subject topic on 06/14/2024.The units have been installed on in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department, Town of Southold, New York. The solar panel installation is in compliance with the requirements of the 2020 Residential Code of New York State, SEI/ASCE 7-16, and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property, and public welfare. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. �P.��OF NEw yo Sincerely, � A. Professional Engineer Current Renewables Engineering yo 106793 info@currentrenewableseng.com FOA, "' SSIONP��C. Exp:9/30/2025 STAMPED 06/14/2024 1760 Chicago Ave Suite J13, Riverside,CA 92507 info@currentrenewableseng.com (951)405-1733 FIELD INSPECTION REPORT DATE COMMENTS nn V' b FOUNDATION(1ST) ------------------------------------ C FOUNDATION (2ND) 'Z Ic O n ROUGH FRAMING& PLUMBING S c L� r INSULATION PER N.Y. STATE ENERGY CODE .S P,,3- C7VWFAft '10002 Go Ili 0 FINAL winduws +-c�.obr� n ADDITIONAL COMMENTS 0-7 Scoff cdkt -7116124 ElcxAnC CeA- 0 c z � Z rv � f J H O z x r� x d ro H ' f\ TOWN OF SOUTHOLD—BUILDING DEPARTMENT o Tov/n Hal Annex 54375 Main road P. ®. Box 1179 Southold, NY 11971-0959 y • Telephone (631) 765-1802 Fax (631) 765-9502 hn— �i�4�e_�oertholdkow- n`.izoc�o,f f Date Received APPLICATION FOR BUILDING PERMITrp I For Office Use Only I D [rp' 0 W E PERMIT NO. SlOrN 5 Building Inspector: APR 1 7 2024 y Applications and forms must be filled out in their entirety.Incomplete_ (. applications will not be accepted. Where the Applicant is,not the owner,.an Ownee.�Authorization form(Page 27p shab be completed,. � 1' '.o p Date: 4 4, OWNER(S)OF[PfROPEU; 7•� A Gj-� Name: _"C4 Cl'rA-m�r�c�n�� SOTM# 1000- L4 Project Address: S10 &C'I rtC4 MeU4- ) y, C��, /) 152- Phone#: (3 g m 2 - - q ) Email: f2.f t -� a S a Cc Mailing Address: iDa G CONTACT'PERSON.- Name: LD Irr,0-0.A'c—,Mailing Address: -/ 4 u/11d Vo PAo,,4 ,4w � ��6 �� �Iq5 Phone#: 6 3 1 d 3 9 2 Email: Co i3 DESIEN PROFESSIONAL INFORMATION.: Name: Mailing Address: Phone#: Email: 'Ib T O INFORMAT�10 . Name: 91 e,M e-13+ 5 � Li Mailing Address: I 4 q Phone#: 2) 1 v 3 4 I Email: pi'y"-e .s e C DESCMPTION OF PRC)po5ED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration []Repair ❑Demolition Estimated cost of Project: "TAther l n64-1-0 Sb)A- V �� l YhuVv> c,C•� �1%.S)-\ $ I f Will the lot be re-graded? ❑YesNo Will excess fill be removed from premises? ❑Yes` i' o i i 1 PROPERTY INkiRI1iAYION Existing use of property: S Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Ye&:KNo IF YES, PROVIDE A COPY. eck:Box•After.Reading:.The.owner/contractor/design pr6fessiana1- is responsible for ap diainage andstorm;weter issues.as provided by . Chapter 236 of the•Town Code:APP.UCATtON IS HEREBY MADE to the Building Department for theissuance,of a Building Permit.pursuant to the Building Zone Ordinance,of the•Town ofSouthold,Suffolk;County,New•York and other applicable laws;Ordinancea.or,Regulattons;:for the construction of buildings,. additionr'alterations or for;removal or demolition as herein described.The.applicant agrees;to_comply with all applicable laws,ordinances,building code, housing code and regulations and.to.admit autFi'oiized inspectors on premises and iri buitdii, forne"cessary inspect ons..False statements made herein are PdnishableasaClAssAr'mis4bi ieinorpqriii5rtt fo Section 21o.45•of the•IVew YorkState Penal LaWo Application Submitted By(print name):Lorraine DiPenta ®Authorized Agent ❑Owner Signature of Applicant:(::�� � —(1,' Date: Ld STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Lorraine D"i Penta being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that'all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewit1 -OUIS J ROMEO Notary Public,State of New York- Sworn before me this No.01 R06314813 Qualified in Suffolk County Commission Expires November 17,20 day of 4 Notary Public j�( PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) C L`�A ��ne> residing at_J g 5 rOl. L( l a 52 I,.rr ra iine. (.do hereby authorize 15LrriQ,rt.,l' C-,)Lq �, LLC ,n .to apply on L my behalf to the Town of Southold Building Department for approval as described herein. ItsIq Owner's Signature Date //�� LOUIS J ROMEO ��>1 e+ C 1 &_M a-Y'( CQy1 C, Notary Public,State of New York No.01 R06314813 Print Owner's Name Qualified in Suffolk County Commission Expires November 17,20 ?_6 2 ®�Ag�FFUQ,�`O BUILDING DEPARTMENT- Electrical Inspector �Z Gym TOWN OF SOUTHOLD i Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1302 - FAX (631) 765-9502 rogerr(&southoldtownny gov- seand(aD-southoldtownny gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN I'NFO[I MATRON (Au information Required) Date: LJ Company Name: E Ica!t �'� �`��'�' � � �-LC Electrician's Name: a "1r'/).ri�' ' License No.. a a �;a Elec. email: ip `s, C c"r") Elec. Phone Igo: �r 21 request an entail copy of Certificate of Compliance Elec. Address.:')Ll 17 ). t 1. I �, 1 _ JOB SITE INFORMATION (All Information Required) �a 5-Z7 p L J)OtC Sf— Narne: avn-L+ C►, �m lk_r ) C O-A_ � I Address: S I*)C_, �t►"ee � Lk ll �52� Cross Street: Q Q Phone No.: Bldg.Permit#: �50_14 5 email: Tax I�liap District: 1000 Section: I Block: Lot: � � BRIEF DESCRIPTION OF VVORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Circle All That Apply- Square Footage: Is job ready for inspection?: YES '' ISO O Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information. (All information required) Service Size01 Ph03 Ph Size: A #Deters Old Meter# ❑RlewService®Fire Reconnect[—]Flood ReconnectOService Reconnect OundergroundOOverhead # underground Laterals 1 2 F1 H.Frame Pole Work done on Service? Y FIN Additional Information: �-, roc,f- ,-� �,n y- , -&o 4cL�­ ;P V -s n M 0 rJ a,L I� - C W a.not.t'�-, S o lam^ - CS 6 R - q oo h-t S p haste I-C� g h2 �, 7 -M- -C rJ�C,9�cj PAYMENT DUDE WITH APPLICATION orrc Workers' CERTIFICATE OF INSURANCE COVERAGEsTATr:J compensation I Bard NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that Carrie Ia.Legal Name&Address of insured(use street address only) 1b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured Work Location of Insured fo„lyrelred lfccver a is or Social Security Nr»rrbar . certain locations in New York State,;e.,Wrap i!p policy) specifically limited!o g2333€i604 2.Name and Address of Entity Requesting Proof of Coverage FNamesurance Carrier (Entity Being Usted as the Certificate Holder) TOW OF SO�TiHOLt7 Point Life hrsurance Company54375 MAIN ROAD ber of Entity Listed in Box"ta, SOUTHOLD,NY 11971 67527 3c.Policy effective period 01/01/2023 to 12/31/2024 4. Policy provides the following benefits. A Both disability and paid family leave benefits. n S.Disability beriefrts only. L�—Jr C.Paid family leave benefits only. 5. Policy covers: ® A,All Of ffm amPloyer's employees eligible under the NYS Disability and Paid Famdv Leave Benefft Law. 0 B.Only the following class or ctasses of employer's employees: Under penally ofperjury.I certify that irutrred has NYSS I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named Disability andfor Paid Family Leave Benefits insurance coverage as described above. Dale Signed 7I1012023 By fr (Signature of insurable carrier's authorized representative or Nn licensed Imwrance Agent of*at insurance ur W) Telephone Number 516-829-8100 Name and Titie Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. V Box 4B.4C or 58 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be Completed by the NY5 Workers'Compensation Board lonly If Box 48,4C or SB have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid.Family Leave Benefits Law(Articfe 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Sigmature of Authorized NYS Workers'Compensation Board Employee, j Telephone Number Name and Title 1 Please Note Only Insurance carriers licensed to write NYS disability and paid family leave benefits insurance Porcies and NYS licensed insurance agents of those insurance carriers are authorized to issue Fcrm D8420.1.Insurance brokers are NOT authorized to issue this form. DB-92iJ.1 (12-21) �(�����Ill��l�fl�1�ll�li9iiillR,lll� A CERTIFICATE OF LIABILITY INSURANCE A�AA!YS UR�lV�GA�N CC DATEIe�►�,DD,YYYY}! 7/12/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUT CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES HOR REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IZED IMPORTANT. If the certificate holder is an ADDITIONAL INSURED,the,policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terns and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT ROBERT S. FEDE INSURANCE AGENCY NAME: PHONE ZI 23 GREEN STREET,SUITE 102 No 61 .E-MA1LNUNTINGTON,NY 11743 ADDRESS:ROBERTS.FEDE INSURANCE INSu SIAFFORDINGCOVERAGEINSURER A:ATLANTIC CASUALTY INS.CO. INSURED Element Energy LLC0 DBA ELEMENT ENERGY SYSTEMS IwsuRe:c: 7470 SOUND AVENUE I"s"�° MATTITUCK,NY 11952 INSIn2ERE: INSURER F COVERAGES CERTIFICATE NUMBER REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE USTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POUCIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES-LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAUS, tNSRLTR TYPE OF INSURANCE Do U Flo POLICY NUMBER MMMI00 EFF PQUCY EXP umn's COMMERCIAL GENERALLIAsruTY L145DO36873 A X X 7/1412023I 7/141Z024 EACH OCCURRENCE $ 3.000,000 CLAIMS-MADE OCCUR IWED PREMISES Ea oearrenea $ 100.000 r Contractual Lia IMA3892038 MED EXP( Ire person) $ 5000 7/19/2022 7/19/2024 PERSONAL a AOV INJURY $ 30011000 L AGGREGATE LIN67AP-1 PER I GENERAL AGGREGATE 3 3,000.000 POL PRO. ICY X "C.JECT LOC {{ PRODUCTS-COtw`P30P AGG $ HE OTR: d i AW07BILE WBN.ITY EOMBXED 5WGLE MIT $ ANY AUTO BODILY INJURY(Per pereenj $ OWNED SCHEDULED AUrOS ONLY AUTOS BODILY INJURY(Per aaideaq S HIRED NOR-OWNED ONLY PROPERTY DAIUAGE AUTOS ONLY A.UrOSONLY arrid�t $ $ UMBRELLA L1AB OCCUR 37113r2O24 H OCCURRENCE $ EXCESS LIAe CLAIMS MADE REGATE $ QED RETENUCN$ VMRKERS COi1PENSJITwN $ AND EMPLOYERS'UABLITV 124494445 PER OTH- ANY PR WRO'TORIPARTNERIEXECUTIVE Y j N 7/13/2023 d' EROFFICERIA�M9ER E(CLUOEG7 N iAEACH ACCICEN7 $ 1 0o (man a<ory In NIIJIf yes,descabe under ISEASE-EA EMPLOYE $ DESCRIPTION OF OPERATIONS below ISEASE-POLICY LIMIT $ NY State DBL DOL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIM(LOCATIONS I VEHICLES(AC 101,AddfflWal Remarks Schedule,may be attee0ed if more Spate in required)CERTIFICATE HOLDER IS ADDITIONAL INSURED Certlificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blaf*et)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Roars THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Robe tS. Fed& ©19aa-2015 ACORD CORPORATION. All rights reserved. arson ��»n��rn1� Tl— ern®r, 1 YSIF New York State Insurance Fund PO Box 66699,Albany,IVY 122C6 I nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) ^n°^A A 8233366N _ = ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 � SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTTTUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE . 12449 444-5 369075 07113/2023 TO 0711312024 7/1112023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-6, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY.INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:IIWWW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WANE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT. THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE iS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU CE FUND tV OIRECTOR,INSURANCE FUND UNDERWRITING ',oa APPROVED AS NOTED oA 5. 2.=B.R# 50 7 q S COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES �,Or BY: AS REQUIRED AND CONDITIONS OF FE NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THEING FOLLOWING INSPECTIONS: TQWNTAV$j� FOUNDATION-TWO REQUIRED N,Y ,IEC FOR POURED CONCRETE ROUGH-FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE ELECTRICAL REQUIREMENTS OF THE CODES OF NEW INSPECTION REQUIRED YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS Additional Certification cl iscbnnec+ mom,,+ be IpCGt-�.e�Q May Be Required. Ou+Side , Iabr-kd and read dy acce,�;bl,e, . • OCCUPANCY OR USE IS UNLAWLFUL WITHOUT CERTIFICATE OF OCCUPANCY Page'I of 2 04/16/2024 Current Renewables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Ciamaricone Residence Project Address: 585 Pacific Street, Mattituck, NY, 11952 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 ��-Of NEwy Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com ti 106793 A F NPR Signed on:04/16/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by W Rafter @ 16 in. OC spacing. The roof is sloped at approximately 30 degrees and has a max beam span of 16.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com ROOF MOUNT SOLAR PERMIT PACKAGE JANET CIAMARICONE 12.000 KW DC GRID TIED PHOTOVOLTAIC SYSTEM 585 PACIFIC ST, MATTITUCK, NY 11952 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES: THESE DRAWINGS ARE SUBJECT TO THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC COPYRIGHT PROTECTION BY US LAW. _ POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY REPRODUCTION IN ANY FORM IS `_ SOLAR PHOTOVOLTAIC INSTALLATION EXPRESSLY FORBIDDEN WITHOUT PRIOR •1 2020 BUILDING CODE OF NEW YORK STATE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES WRITTEN APPROVAL FROM CURRENT 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED RENEwABLES ENGINEERING INC ,, - • 2020 RESIDENTIAL CODE OF NEW YORK STATE ! 2020 EXISTING BUILDING CODE OF NEW YORK STATE 4, ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE 2020 FIRE CODE OF NEW YORK STATE UNDERSIGNED Current 2020 MECHANICAL CODE OF NEW YORK STATE 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 R@neYVarrS 2020 PLUMBING CODE OF NEW YORK STATE 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE SUCH AS GeoCel 2300 CLEAR SEALANT Engineering 2017 NATIONAL ELECTRICAL CODE 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED .w sr 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, CURRENT RENEWABLES x MECHANICAL,OR BUILDING ROOF VENTS ENGINEERING INC. 1760 CHICAGO AVE SUITE AHJ:TOWN OF SOUTHOLD 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS J-13.RIVERSIDE CA92507 THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE PHONE(951)-405-1733 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED WNW CRENG CO CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S CONTRACTOR INFO LEGEND INSTALLATION INSTRUCTIONS" 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA uM UTILITY METER Lc LOAD CENTER REGULATIONS 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" SP MAIN SERVICE PANEL INV INVERTER 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY CZ SYS BUILDING INFORMATION ❑ GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. C COMBINER SUB SUB PANEL 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. AC DISCONNECT LP BACKUP LOAD PANEL 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE ELEMENT ENERGY LLC. NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF 7478 SOUND AVENUE,MATTITUCK, 2 STORY HOUSE SINGLE FAMILY RESIDENCE REQUIREDARECOGNIZEDELECTRICALTESTINGLABORATORY. NEW31)779199 ❑ MODULE I Q IQ CONTROLLER 2 PH:(61) 79 793 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 718" services@e2sys.com CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U ROOF OBSTRUCTIONS ATT BATTERY ABOVE ROOF SURFACE. Licence-ME-52689 36"ACCESS PATHWAYS 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE (MASTER ELECTRICIAN) APN : 141.-4-14.1 RATED FOR EXPOSURE;TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS.WITHIN Licence-HI-67461 QH Q.HOME HUB ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH (SUFFOLK HOME IMPROVEMENT) SHEET INDEX 18 ACCESS PATHWAYS OPEN SPACE OR TYPE T AN IN MINIMUM 3N ALUMINUM CONDUIT ROOF ACCESS POINT AC ESS DISCONNECT 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, JANET CIAMARICONE STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO SEPTIC TANK THE PURPOSE INTENDED: PV-1.0 �COVER PAGE MBE MAIN BREAKER 585 PACIFIC ST,MATTITUCK,NY ENCLOSURE 11952 PV-2.0 SITE PLAN AUTOMATIC TRANSFER SSS LEACH LINES TS SWITCH PV SUMMERY PV-2.1 ROOF PLAN PROPANE TANK WIND SPEED 128 SYSTEM SIZE(K WDC) STC 400 x 30 =1z000 PV-3.0 STRUCTURAL OP PERMANENT ANCHOR (::D WELL SNOW LOAD 25 _ RTC 376.7 x 1 30 =11 3D1 O POWER LINES EXPOSURE CATEGORY C SYSTEM SIZE 9.600 Qzao PV-4.0 ELECTRICAL 3LD ` (K �F �� TE T IT$q«tpfpAOR y W J MODULES 30 CANADIAN SOLAR NO LADDER ACCESS P Qn -400MS-HL PV-4.1 ELECTRICAL SLID NO NUMBER : 9613816501 RT A. MICRO-INV.QTY 30 CS6R IL (STEEP GRADE p�E , �4p MICRO ENPHASE IQ8MC-72-M-US PV-4.2 ELECTRICAL PHOTOS INVERTER S STUB-OUT OR GROUND LEVEL UTILITY PV-5.0 BOM ❑ OBSTRUCTIONS) METER NO: 98347321 OPAIISLANDPDWERAUTHDRITY cir PV-6.0 1,SIGNAGE & PLACARD ® SKYLIGHT r 4, PV-7.0 SPECS+ esuiption Date ❑ RESTRICTED ACCESS �SFO 106793 �� RA INITTIIALDESIGN 4/117/2024 CONDUIT AjQ�FESSII0 AS GAS SHUT OFF PROJECT# 8959 Exp:9/30/2025 Hzo WATER SHUT OFF Stamped 04/17/2024 DATE DRAWN 4/17/2024 DRAWN BY ER O SERVICE DROP SHEET# PV-1.0 PB JUNCTION BOX TITLE pM PRODUCTION METER COVER PAGE R324. SEPARATE , EROOFPL ENLARGED VIEW \ LEGEND NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. UM UTILITY METER AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. 36"ROOF ACCESS POINT FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM LL C AC u M SP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE li li SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING I C❑ COMBINER STRUCTURAL NOTES: / THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS 1.THESE PLANS ARE STAMPED FOR MS P AC DISCONNECT ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR STRUCTURAL CODE COMPLIANCE OF MODULE MECHANICAL EQUIPMENT. THE ROOF FRAMING SUPPORTING THE R324.6.2 SETBACK AT RIDGE: PROPOSED PV INSTALLATION ONLY. \ ROOF OBSTRUCTIONS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 2.THESE PLANS ARE NOT STAMPED I 36' ACCESS PATHWAYS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN FOR WATER LEAKAGE. AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES of A THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE, 1PV MODULES,RACKING,AND ii 18"ACCESS PATHWAYS COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 ATTACHMENT COMPONENTS MUST l V) REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A FOLLOW MANUFACTURER GUIDELINES ROOF ACCESS POINT EXPRESSLY FORBIDDEN WTHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A U WRITTEN APPROVAL FROM CURRENT HORZoNTAL RIDGE. AND REQUIREMENTS. RENEWABLES ENGINEERING INC. 4. PLEASE SEE THE ACCOMPANYING ILL R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS STRUCTURAL CALCULATIONS REPORT U Current AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED FOR ADDITIONAL INFORMATION. ROOF LINE a Renewables THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE 5. PRIOR TO THE COMMENCEMENT OF Engineering PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. WORK,THE SOLAR INSTALLER SHALL 9 9 NOTES: VERIFY THE ROOF FRAMING CURRENT RENEWABLES 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED INFORMATION BEFORE INSTALLATION ENGINEERING INC. ON ACTUAL SITE CONDITION AND AND NOTIFY THE E.O.R. IF THERE IS 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 MEASUREMENTS. ANY INCONSISTENCY BETWEEN SITE PHONE(951)-405-1733 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS VERIFICATION AND THE FOLLOWING: WWW.cRENG.CO INCORPORATED INTO THE 2017 NEC AND UL 2x8 RAFTERS @ 16"OC SPACING WITH CONTRACTOR INFO STANDARD 1741. A MAX UNSUPPORTED SPAN EQUAL 3. EXISTING ROOF VENT SHOULD NOT BE TO OR LESS THAN 16 FT. COVERED. WIND SPEED 128 mum SNOW LOAD 25 36"ROOF ACCESS POINT EXPOSURE CATEGORY C E2SYS8 ELEMENT ENERGY LLC. 1 NEW yo PROPERTY LINE ROOF OBSTRUCTION 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 SHED PH:(631)779 7993 Rj A. 'Q _.—_ _____ FENCE/GATE services e2s scom r `--'-^----- __ Licence-ME-52689 ----_-._-_—_ (MASTER ELECTRICIAN) Licence-HI-67461 W 1T 1" (SUFFOLK HOME IMPROVEMENT) 106793 �' JANETCIAMARICONE 0) 585 PACIFIC ST,MATTITUCK,NY SS p ION �! "' �- 1 11952 CO' () Exp:9/30/2025 SYSTEM SIZE PV SUMMERY • •' •' � U (KWDC) STC 400 X 30 =12.000 Stamped 04/17/2024 ! 40'-7" Lj__ Prc 376.7 X 30 =11 3D1 283-9 LLJJU SYSTEM SIZE(K WAC) 9.600 @240 1 MODULES 30 CANADIAN SOLAR ' ►"` i CS6R-40OMS-HL Co 1 o MICRO-INV.QTY 30 1 •• 1 - MICRO 1 ' INVERTER ENPHASE IQSMC-72-M-US �� � '•� •••\l UTILITY '•! '.'•: ;! 'l [LONG ISLAND POWER AUTHORITY DRIVEWAY . 01 3 1• 1. Rev Description Date I \ ♦ ♦ i A INITIAL DESIGN 4/17/2024 I PROJECT# 8959 PROPERTY LINE DATE DRAWN 4/17/2024 DRAWN BY E.R S I T E PLAN SHEET# PV-2 0 6 TITLE SCALE: 3/12811 = 11-Olt SITE PLAN ARRAY AREA LEGEND ARRAY ROOF ROOF TOTAL ROOF AZIMUTH #OF AREA AREA AREA AREA uM UTILITY METER MODULES COVERED BY COVERED BY (Sq.Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) SP MAIN SERVICE PANEL #1 67° 9 189.18 2211 8.56 COMBINER #2 337° 4 84.08 2211 3.80 C #3 157° 4 84.08 2211 3.80 28.52 ROOF#2 AC DISCONNECT #4 247° 4 84.08 2211 3.80 MODULE #5 67° 4 84.08 2211 3.80 ROOF OBSTRUCTIONS C AC UM #6 157° 5 105.10 2211 4.75 ® 36"ACCESS PATHWAYS MSP ® THESE DRAWINGS ARE SUBJECT TO 18"ACCESS PATHWAYS COPYRIGHT PROTECTION BY US LAW REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT ROOF#1 RENEWABLES ENGINEERING INC. Current * * — Engineer"irg CURRENT RENEWABLES t— W ENGINEERING INC. 1760 CHICAGO AVE SUITE (�_ = J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 v(�D �06793 WN^N-CRENG.CO A��FESSI CONTRACTOR INFO Exp:9/30/2025 Stamped 04/17/2024 MEN I E ROOF#3 ZSYSS 1'-6" ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 Uservices@e2sys.com Licence-ME-52689 U— (MASTER ELECTRICIAN) Licence-HI-67461 V (SUFFOLK HOME IMPROVEMENT) n- JANET CIAMARICONE 585 PACIFIC ST,MATTITUCK,NY 11952 ROOF#5 PV SUMMERY SYSTEM SIZE(K WDC) STC 400 X 30 = 2.000 PTC 376.7 X 30 = 1.301 (N)30 CANADIAN SOLAR CS6R-400MS-HL SYSTEM SIZE g.600 @zaD (K WAC) MODULES 30 CANADIAN SOLAR CS6R-40OMS-HL ROOF#4 MICRO-INV OTY 1 30 MICRO INVERTER ENPHASE IO8MC-72-M-US UTILITY ONG ISLAND POWER AUTHORITY LIPA) Rev Description Date A INITIAL DESIGN 4/17/2024 3' PROJECT# 8959 DATE DRAWN 4/172024 DRAWN BY ER 2 ROOF PLAN ROOF#6 SHEET# PV-2.1 TITLE SCALE: 1/8" = 1'-011 ROOF PLAN TABLE 1 TABLE 2 s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG s2 ATTACHMENT IRONRIDGE HALO ULTRA GRIP ROOF 1 30 COMP SHINGLE RAFTER 2X8 16" 48" 24" s3 RAIL IRONRIDGE XR-100 RAIL ROOF 2 30 COMP SHINGLE RAFTER 2X8 16" 48" 2411 ROOF 3 30 COMP SHINGLE RAFTER 2X8 16" 48" 24" ROOF 4 30 COMP SHINGLE RAFTER 2X8 16" 48" 24" ROOF 5 30 COMP SHINGLE RAFTER 2X8 16" 48" 24" ROOF 6 30 COMP SHINGLE RAFTER 2X8 16" 48" 2411 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current r, nevr ables Engineering CURRENT RENEWABLES ENGINEERING INC. S3 pF NEwy 1760 CHICAGO AVE SUITE J-13.RIVERSIDE CA 92507 [,( T A. PHONE:(951)-405-1733 R\ l4D�'P* WWW.CRENG.CO 4 CONTRACTORINFO 4,, r _ cr_ TABLE : PENETRATION c� GUIDE FOR INSTALL jd ®m ti J'f`O 1 p1F 0E679IO3 N�N,� TWO IO R MORE ROWS OF PANELS I I I I I I I I I I I I I I CZS YS 9 2.5"MIN.EMBED. :2 #14 SS Exp:9/30/2025 ELEMENT ENERGY LLC. SOUND AVENUE,MATiITU CK, Stamped 04/17/2024 NEWYORK,11952 PH:(631)779 7993 sevices@e2sys.com x 3x RD STRUCTURAL WOOD Licence-ME-52689 CREWS TO EXISTING RAFTER (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) S I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I JANET CIAMARICONE ENLARGED VIEW 585 PACIFIC ST,MATTITUCK,NY 11952 STACKED STAGGERED FULLY STAGGERED PV SUMMERY S3 SYSTEM SIZE (KWDC) STC 400 X 30 =12.000 ONE ROW OF PANELS PTC 376.7 X 30 =11,301 sz SYSTEM SIZE 9.600 Q240 (K WAC) MODULES 30 CANADIAN SOLAR CS6R-4ODMS-HL I I I I I I I I I I I I I MICRO-INV QTY 30 SEE ENLARGED VIEW MICRO ENPHASEIQSMC-72-M-US I I I I I I I I I I I I I INVERTER UTILITY 'PI ISLAND POWER AUTHORITY FULLY STAGGERED STACKED/STAGGERED Rev Description Date st �— A INITIAL DESIGN 4/17/2024 PROJECT# 8959 DATE DRAWN 4/17/2024 ATTACHMENT DETAIL DRAWN BY ER SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING MAX.CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST ACCOUNT NUMBER : 9613816501 ��of- NEFW 39.90 X 1.25 = 49.88AMPS 50A FUSES-OK S.NO. ITEMS DESCRIPTION QTY. 1 PV MODULE CANADIAN SOLAR 30 METER NO: 98347321 � �D CS6R-400MS-HL 0 W r" 099128 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 30 �N�O CTRiGP� � 3 COMBINER ENPHASE COMBINER BOX 1 ARpFESSIONP� X2-I Q-AM 1-240-4 60A FUSED RATED 4 AC DISCONNECT D322NRB SQUARE D 1 (E)UTILITY METER STAMPED 04/17/2024 TO UTILITY KNIFEBLADE LOCKABLE GRID NEMA 3R UL LISTED THESE DRAWINGS ARE SUBJECT TO 3 (N)ENPHASE (E)200ARATED COPRODUCTIONPYRIGHT PRONECTIOFORM S ANY COMBINER BOX N BY US LAW MAIN SERVICE PANEL 1 1 PH,120/240V 60HZ EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 2 (E)200AB2P MAIN RENEWABLES ENGINEERING INC. LESS li§z MS (TOP FED) Current 1 BRANCH OF N Renewabies 10 PV MODULE Engineering ` 1 (N)15A:� 77_ CURRENT RENEWABLES r ENGINEERING INC. •� 1760 CHICAGO AVE SUITE (N)20A I J-13.RIVERSIDE CA 92507 2 BRANCH OF 10 I � I (N)LINESIDE TAP VIA UL PHONE (951)-405-1733 PV MODULE N I •� LISTED CONNECTOR WWW.CRENGCO f (N)2oA� I 4 ' CONTRACTOR INFO I I (N)FUSED II I I(N)2DA-/TN_ I I AC DISCONNECT I I I L------ --- ---- 3 BRANCH OFIO L——————— �b � mum PV MODULE N. r--- ---� CZSYSAU I ELEMENT ENERGY LLC. MODULE B C I 7470 SOUND AVENUE,MATTITUCK, MANUFACTURER CANADIAN SOLAR L------ — NEW YORK,11952 (E)GROUNDING ELECTRODE PH:(631)779 7993 1-#6GEC COPPER CONDUCTOR#6 COATED services@e2sys.com MODULE MODEL CS6R-40OMS-HL A FREE AIR BONDED - Licence-ME-52689 EXISTING LIFER TIE IN (MASTER ELECTRICIAN) Licence-HI-67461 MODULE(W) 400 (SUFFOLK HOME IMPROVEMENT) MODULE PTC(W) 376.70 MODULE 15c(A) 13.85 JANET CIAMARICONE NOTE:MODULE voc(v) 36.80 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS 585 PACIFIC ST,MATTITUCK,NY11952 MODULE Imp(A) 12.99 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. MODULE Vmp(V) 30.80 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH PV SUMMERY PROPER JUNCTION BOX AT EACH END PER 690.31A SYSTEM SIZE STC 400 X 30 =12 000 (KWDC) PTC 376.7 X 30 =11.301 WIRE CALCULATION SYSTEM SIZE 9.600 @240 (K WAC) STARTING ADJUSTMENT MAXIMUM MODULES 30 CANADIAN SOLAR STARTING TEMPERATURE CS6R-400MS-HL CONDUCTOR CONDUCTOR CURRENT FACTOR FOR ADJUSTED CURRENT MICRO-INv ory 30 TAG CONDUIT ALLOWABLE TEMPERATURE M ICRO CORRECTION DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO ENPHASE IosMc-n-M-us QTY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (°C) INVERTER CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS ONG ISLAND POWER AUTHORITY 310.15(B)(16) 310.15(B)(2)(a) UTILITYuPA) IN RACEWAY 310.15(B)(3)(a) IN RACEWAY 2 12 SKU:Q-12-RAW-300, THHN A N/A FREE AIR 30 90, 13.3 0.96 1 28.80 16.63 Rev Descrip,ion Date 1 8 THWN-2 BARE COPPER-(GROUND) A INITIAL DESIGN 4/1 J/2024 3 8 THWN-2 COPPER-(L1,L2) B 3/4" PVC 55 90° 39.9 0.96 1 52.80 49.88 1 8 THWN-2 COPPER-(GROUND) PROJECT# 8959 3 6 THWN-2 COPPER-(L1,L2) DATE DRAWN 4/17/2024 C 1 8 THWN-2 COPPER-(GROUND) 3/4" PVC 75 90° 39.9 0.96 1 72.00 49.88 DRA SHEET Y ER PV40 TITLE ELECTRICAL 3LD I BACkFEED FUSE SIZING MAX.CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST ACCOUNT NUMBER : 9613816501 ,-OF NE�,Y pE M'�i4 39.90 X 1.25 = 49.88AMPS 50A FUSES-OK S.NO. ITEMS DESCRIPTION CITY. co 1 PV MODULE CANADIAN SOLAR 30 METER NO: 98347321 CS6R-400MS-HL z D W m 'L osslz8 = 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 30 N�Q CTF' 3 COMBINER ENPHASE COMBINER BOX 1 AROFESSIONP� X2-I Q-AM 1-240-4 60A FUSED RATED 4 AC DISCONNECT D322NRB SQUARE D 1 (E)UTILITY METER TO UTILITY STAMPED 04/17/2024 KNIFEBLADE LOCKABLE GRID NEMA 3R UL LISTED THESE DRAWINGS ARE SUBJECT TO 3 (N)ENPHASE (E)200ARATED COPYRIGHT TPROION WANYON BY US FORM ISLAW. COMBINER BOX MAIN SERVICE PANEL 1 1 PH,120/240V 60HZ EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 2 CELL (E)200AB2P MAIN RENEWABLES ENGINEERING INC. WIRE LESS MODEM COMMS (TOP FED) Current 1 BRANCH OF IQ GATEWAY 10 N �} PV MODULE " Englneering N)15A:� • • CURRENT RENEWABLES ./�. ENGINEERING INC. •�• 1760 CHICAGO AVE SUITE 2 BRANCH OF 10 (N)20A • J-13,RIVERSIDE CA 92507 (N)LINESIDE TAP VIA UL PHONE:(951)-405-1733 PV MODULE N •�• LISTED CONNECTOR WWW CRENG CO (N)20'� 4 • (N)FUSED CONTRACTOR INFO •�i AC DISCONNECT • 3 BRANCH OF 10 PV MODULE NV CZSYSUA ELEMENT ENERGY LLC. MODULE CANADIAN SOLAR B j 7470 SOUND AVENUE,MATNTUCK, NEW YORK,11952 MANUFACTURER (E)GROUNDING ELECTRODE PH:(631)779 7993 1-#6GEC.COPPER CONDUCTOR #6COATED services@e2sys.com MODULE MODEL CS6R-400MS-HL A FREE AIR BONDED — Licence-ME-52689 EXISTING UFER TIE IN (MASTER ELECTRICIAN) Licence-HI-67461 MODULE(W) 400 (SUFFOLK HOME IMPROVEMENT) MODULE PTC(W) 376.70 MODULE I5c(A) 13.85 JANET CIAMARICONE MODULE Voc(V) 36.80 NOTE: 585 PACIFIC ST,MATTITUCK,NY 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS 11952 MODULE Imp(A) 12.99 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. MODULE Vmp(V) 30.80 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH PV SUMMERY PROPER JUNCTION BOX AT EACH END PER 690.31A SYSTEM SIZE(K WDC) STC 400 x 30 =,2 000 PTC 376.7 X 1 30 =11.301 SYSTEM SIZE(K WAC) 9.600 Q240 WIRE CALCULATION MODULES 30 CANADIAN SOLAR C56R 100MS-HL MICRO-INV.CITY 30 STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM MICRO ENPHASE IQ8MC-72-M-US CURRENT FACTOR FOR ADJUSTED CURRENT INVERTER R CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION ONG ISLAND POWER AUTHORITY TAG DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO unury 'I IPA) QTY. SIZE(AWG) SIZE&TYPE AMPAB)(1CITY RATING (°C) CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(13)(3)(a) IN RACEWAY SKU: Q-12-RAW-300, THHN Rev Desuiption Date A 2 12 N/A FREE AIR 30 90° 13.3 0.96 1 28.80 16.63 A INITIAL DESIGN ai,7/zoz4 1 8 THWN-2 BARE COPPER-(GROUND) 3 8 THWN-2 COPPER-(L1,L2) PROJECT# 8959 B 3/4" PVC 55 90° 39.9 0.96 1 52.80 49.88 DATE DRAWN 407i2024 1 g THWN-2COPPER-(GROUND) DRAWN BY E.R 3 6 THWN-2 COPPER-(L1,L2) SHEET# PV-4.1 C 1 8 THWN-2 COPPER-(GROUND) 3/4" PVC 75 90° 39.9 0.96 1 72.00 49.88 TITLE ELECTRICAL 3LD EXISTING SERVICE PANEL PHOTOS of NEwy m h Z 099128 c1RlcP_�`�, - -- - - � '"�'FSSIO�►� STAMPED 04A 7M24 r THESE DRAWINGS ARE SUBJECT TO i C) COPYRIGHT PROTECTION BY US LAW. Co REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR �y WRITTEN APPROVAL FROM CURRENT cn RENEWABLES ENGINEERING INC. Q 0=- Current �, ='pnewable Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.0 RENG.CO CONTRACTORINFO i ® M EZSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTRUCK,ANEW 19 PH:(431)31)779 179 7993 lip services@,e2s,s,c.rn n Licence-ME-52689 (MASTER eELECTRICIAN) HI-67461 i (SUFFOLK HOME IMPROVEMENT) f f, Irk JANET CIAMARICONE 585 PACIFIC ST,MATTITUCK,NY 11952 PV SUMMERY r SYSTEM SIZE(K WDC) STC 400 X 30 = 2.000 PTC 376.7 X 1 30 = 1.301 SYSTEM SIZE 9.600 (�240 (KWAC) MODULES 30 CANADIAN SOLAR CS6R-4OOMS-HL MICRO-INV.QTY 30 fit # MICRO : ENPHASE IQ6MC-72-MLS ' INVERTER tt �f UTILITY 'PA ISLAND POWER AUTHORITY ) / Rev Description Dale -�' A INITIAL DESIGN 4/17/2024 AEDATE CT# 8959 RAWN 4/17/2024 BY E.R # PV-4.2 _ TITLE ELECTRICAL PHOTOS MATERIAL LIST °FNEwY o COPS M�'��v ELECTRICAL EQUIPMENTS ,* 46 cD W QTY. PART TYPE PART NUMBER DESCRIPTION z 09912 30 MODULE CS6R-400MS-HL CANADIAN SOLAR CS6R-400MS-HL N�oA < - 30 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US ROFESSIONP\. 1 FUSED AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 311 UL LISTED STAMPED 04/17/2024 1 COMBINER X2-1Q-AM 1-240-4/4C X2-1Q-AM 1-240-4/4C 2 TAP CONNECTORS IPC TAP IPC INSULATION PIERCING CONNECTORS THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE.(951)405-1733 WWW.CRENG.CO CONTRACTOR INFO BREAKER/ FUSES QTy• PART TYPE PART NUMBER DESCRIPTION mum 1 FUSES 50A FUSES GENERAL 50A FUSES E2SYSI 3 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) RACKING JANET CIAMARICONE QTy. PART TYPE PART NUMBER DESCRIPTION 585 PACIFIC ST,MATTITUCK,NY 11952 44 RAILS & SPLICES XR-100-168A XR100, RAIL 168" BLACK PVSUMMERY SYSTEM SIZE 12 RAILS & SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 (KWDC) STC 400 X 30 = 2000 PTC 376.7 1 X 1 30 = 1.301 92 CLAMPS & GROUNDING UNIVERSAL MODULE CLAMP, BLACK SYSTEM SIZE g600 �240 (KWAC) 64 CLAMPS & GROUNDING UFO-STP-35MM-M1 STOPPER SLEEVE, 35MM, MILL MODULES 30 CANADIAN SOLAR C56R40OMS-HL 16 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE MICRO-INV OTY 30 MICR NVERTO ER ENPHASE IQ8MC-72-M-US 92 ATTACHMENTS QM-HUG-01-B1 HALO ULTRA GRIP,BLACK UTILITY ONG ISLAND POWER AUTHORITY IPA) Rev Description Date A INITIAL DESIGN 4/17/2024 PROJECT# 8959 DATE DRAWN 4/17/2024 DRAWN BY E.R SHEET# PV-5.0 TITLE BOM CAUTION ��OFNE►.�y �P O�MANi O,p MULTIPLE SOURCE OF POWER r g D W � W 099128CTR% = NCO < - �ESSIO � STAMPED Wl7=4 T_ THESE DRAWINGS ARE SUBJECT TO �- COPYRIGHT PROTECTION BY US LAW. to REPRODUCTION IN ANY FORM IS C_J EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT U RENEWABLES ENGINEERING INC. Q Current M Renewables • PHOTOVOLTAIC I I I• Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE 690.12 >= PHONEY(511))I-405-1733507 WWW.CRENG LO -J CONTRACTORINFO I MAIN SERVICE PANEL PV ARRAY TURN RAPID I • INER SHUTDOWN SWITCH TO I • ' ' AC DISCONNECTCGSYS' THE "OFF" POSITION TO AC AC NORMALOPERATING VOLTAGE1 VOLTS UTILITY METER I ELEMENT ENERGY LLC. - AVENUE,SHUT DOWN PV SYSTEM 690.14,690.15,690.54 7470 SOUNDNEW YORK,11952TfITUCK, AND REDUCE SHOCK PHices 2sys.c3 _ services�ale2sys.com PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL Licence-ME-52689 HAZARD IN THE ARRAY P M (MASTER ELECTRICIAN) �• • PANEL IS AC DISCONNECT PER NEC690.17 Licence-HI-67461 SEC690.56(C)(1)(B) • I SOURC PHOTO— VOLTAIC (SUFFOLK HOME IMPROVEMENT) RATED AC OUTPUT CURRENTAMPS JANETCIAMARICONE NORMALAC OPERATING VOLTAGE • 585 PACIFIC ST,MATTITUCK,NY 11952 690.54 PVSUMMERV SYSTEM SIZE K"°C' STC 76 X 30 11300 OPTIONAL SOLAR LOAD CENTER PTC 3767 X 30 =1 . 01 ARRAY SYSTEM SIZE 9.600 @240 K WAC) MODULES 30 CANADIAN SOLAR C56R-40OMS-HL MICRO-INV.QTY 30 MICRO ENPHASE IQSMC-72-M-US NOTES- NVERTER J/B UTILITY ONG ISLAND POWER AUTHORITY LIPA) 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Date INVERTER OUTPUT CONNECTIONA. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A INITIAL DESIGN 4/17/2024 I• NOT • MACHINE PRINTED LETTERS OR ELECTRO-PLATING. NEC 690.31(G)(3)&(4),CRC R324.7 B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. PROJECT# 8959 • ' ' 'ENT I . C. AERIAL FONT. DATE DRAWN 4/17/2024 (UNLESS BUSBAR IS FULLY RATED) L — 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWNBY ER 705.12(D)(2) PHOTOVOLTAIC POVVER SOURCE THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-6.0 HAND-WRITTEN. TITLE EVERY 1U ON CONDUIT AND ENCLOSURES 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. Ca n a d i a n Solar ENGINEERING DRAWING(mm) CS6RJOOMS HL/I-V CURVES A A Rear View Frame Cross Section A-A A-A 13 - - 131 THESE DRAWINGS ARE SUBJECT TO c+s 35 to ._.________ - -._-.__.fob-- _..____' __ COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR 7 -.. 7' WRITTEN APPROVAL FROM CURRENT a 6. t RENEWABLE$ENGINEERING INC. 4 3. _ Current Mounting Hole 2 ``" '' ' RIErnewableS v a• � - ---- -- --- -- - - 310,52025303540650g60 5,a,ymn3a35,a.Ssos6a Engineering R fouowrm, sY■ H i Ku 6 (All-Black) ■ GW 45'c■ CURRENT RENEWABLE$ - 1,I31 - ! 6rowma g'c f ENGINEERING INC. -4_ ■ 4W*hW 6rc■ 1760 CHICAGO AVE SUITE ! arowmd J-13,RIVERSIDE CA 92507 ALL BLACK MONO PERC PHONE(951)-405-1733 ELECTRICAL DATA I STC* MECHANICAL DATA WWW CRENG CO 380 W 405 W C56R-380/385/390/395/400/405MS-ML Specfiwtion Data CONTRACTOR INFO CS6R-380 1 385 1 390 1 395 1 400 1 405MS-H L Nominal Max.Power(Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type Mono-crystalline Opt Operating Voltage(Vmp)30.0 V 302 V 30A V 30.6 V 30.8 V 31.0 V Cell Arrangement 108[2 X(9 X 6)] ..,. Opt Operating Current(Imp)12 69 A 12 77 A 12.84 A 12.91 A 12.99 A 13.07 A Dimensions 1722 x 1134 x 35 min _._.._ MORE POWER 25 tit Industry Leading Product Warranty on Materials Open Circuit Voltage(Voc) 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V (67.8 x"A x 1.38 in) glum t7 J and Workmanship* Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 22.4 kg(49.4 Ibs) C 2 SYSS Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% 3.2 mm tempered glass with anti-ref- ' Module power up to 405 W --- ---_-_-_------._. --- ----. Front Cover 44r�yy Operating Temperature -40°C-+85°C Anodized edatlna Module efficiency Up t0 20.7% Frame Anodized aluminium alloy, ELEMENT ENERGY LLC. 25 Linear Power Performance Warranty* Max.System Voltage 1000V(IEC/UL) -"--"-" --- -" -" ""--- "-----` -- _- 7470 SOUND AVENUE,MATTITUCK, y�ss _- J-Box IP6--3 bypass diodes __ --_-__---- NEW YORK,11952 TYPE 2(UL 61730 1000V) - - _ - --. , Module Fire Performance Cable 4 min (IEC),12 AWG(UL) PH:(631)779 7993 or CLASS C(TEC 61730) services@e2sys.com 4) Lower LCOf&system cost t#year power degradation no more than 2!4 Max Series Fuse Rating 25 A Connector T6,MC4,MC4-EV02 or MC4-EV02A Licence-ME 52669 Subsequent annual power degradation m0 more an OSS% Application Classification Class A Cable Length (MASTER ELECTRICIAN) -Subpa to the terms and conditiwts contained in the applicable Canadian Soles Licked --- - ----... ---- ----- (Including Connector) 15501iNm( .0 1100 Licence-HI-67461 61 in)(+)/ mm(433 in)(-p /' Comprehensive LID/LeTID mitigation warranty statetnent.Also this 25-year lkrited product sranarty 1s a Ianle Power Tolerance 0-+10 W ^9 only ---.- ------ --_-. _._-_ (SUFFOLK HOME IMPROVEMENT) um installed and operamy on residential rooftops in certain regions. •Under Standard Test Conditions(STC)of irradiance of 1000 W/m%,spectrum AM 1.5 and cell tempo- Per Pallet 30 pieces technology,up to 50%lower degradation ...__..............._._........ rat re of 251C. Per Container ati HQ) rit u local pieces JANET CIAMARICONE MANAGEMENT SYSTEM CERTIFICATES* *For detailed information,pease contact your Canadian So sake and ISO 9001 2015!Quality management system tedtar� tawes. 585 PACIFIC ST,MATTITUCK,NY Better shading tolerance ISO 14001:�15 J standards for environmental management system C� ISO 45001:2018/International standards for occupational health&safety ELECTRICAL DATA I NMOT* 11952 TEMPERATURE CHARACTERISTICS PRODUCT CERTIFICATES* CS6R-380/38•S/390/395/400/405MS-HL PV SUMMERY __-- _--------_--__. - ---_ _ - Speciflcat)on Data SYSTEM SIZE MORE RELIABLE IEC 61215/IEC 61730/CE Nominal Ma.x.- max_ - 84 W Power(P ) 2 288 W 29_ _ 1 W 295 W 299 W 303 W STc 400 x 30 =12 000 cEc fisted(us California)/FSEc(us Ronda) --- -�----_ Temperature Coefficient(Pmax) -0.34%/°C (K WDC) Opt Operating Voltage(Vmp)28.1 V 28.3 V 28.4 V 28.6 V 28.8 V 29.0 V UL 61730/IEC 61701/IEC 62716 PTC 376.7 1 X 1 30 =11.301 Tak-ay Opt Operating Current(Imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A Temperature Coefficient(Voc) -0.26%/°C SYSTEM SIZE Minimizes micro crack impacts / 9.600 .mzao -pen Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/°C (K WAC) CANADIAN SOLAR v cvoa� �"`• Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 1123 A Nominal Module Operating Temperature 42 t 3°C ODULES 30 CS6R-40OMS-HL The specific cMifirates applicable to different module types and markets will vary, *Linder NrrniW Module rat T MICRO-INV.OTY 30 Hell snow load U to 8100 Pa, and therefore not as of the certifications hood herein will s'nx'�feO�y aptly to the am6iee temperature 2 o�wind speed I nVs, (NMon.i radante of eon wrm spectrum AM 1 s, MICRO *** p ENPHASE IQ8MC-72-M-US wind load u to 5000 P * °products �pe�� contactcontact "y�I���you Please t Solar sales a�feP` ` PARTNER SECTION INVERTER p a co confirmconfirmthe specispecificcer0fttates arailabk for your Product and appli� iemthe regions ._......._ _._____. ............ ............_ ...._. .___..._.._. ONG ISLAND POWER AUTHORITY +n Which the products will be used. UTILITY LI PA) -...- _,....__._.__._._.__...__-.................___..........._..._....._... CST SOLAR(USA)CO.,LTD.is committed to providing high quality solar photovoltaic modules,solar energy and battery storage solu0om to cistorrlem The company was recognized as the No.1 module suppW for •The speafrstiorS,and ken,features contained in this ciatasheet Rev Description Date may deviate sightly from our actual quality and performlance/price ratio in the THIS Module Custornef Insight products due to the on going mnwation and product enhancement.CS]Solar Co.,Ltd.reserves the A INITIAL DESIGN 411112021 Survey.Over the past 20 years,R has SIKCffiflllly delivered over 70 GIN non to make necessary adfusanem to lice information described herein at arty time without further notice. *For detailed adomwtion,pease refer to the Ltstaeabon Manual. of prerniurri-qua6lIy solar Modules across the world. Pknse be kindly ativised that w modules should be handled and Installed by qualified people wM ......................................_.-........_.._.................-.............. .__..............-....._.-.-_......_-.--........ nave Professional skills and pose carefully read the safety and Installation instructions before using E _._.__...... ..............I...._.........--........ 9959 our PV modules. :.................................................................................................................. : CSI SOLAR(USA)CO.,LTD. DATE DRAWN 4/17/2024 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94598,USA www.csisolar.com/na (service.ca@csisolar.com DRAWN BY ER CST SOLAR(USA)CO..LTD. Aug 2022 1 All rights reserved I PV Module Product Datasheet v1.1 C25_F23J1_NA SHEET a PV-7 0 TITLE MODULE SPEC ENPHASE IQ8MC Microinverter Commonly used module pairings' w 260-460 wModule compatibility To meet compatibility.PV modules must be within the following max.input DC voltage and max.nodule lw Module compatibility can be checked at nit M://enphase.com/installer/ntiadnvwtets/c.1c,"t,. THESE DRAWINGS ARE SUBJECT TO MPPT voltage range v 25-45 _ COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS Operating range v � EXPRESSLY FORBIDDEN WITHOUT PRIOR Min./Max.start voltage v 22/56 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.input DC voltage v 60 Max.continuous operating DC current _ A 14 Current Max.input DC short-circuit current A 25 RenewaV Max.nods Iw A 20 _ Engineerir Overvoltage class DC port CURRENT RENEWABLES OCptxtbsol;teedcuRera ens D ENGINEERING INC. PV array configuration Ungrounded array;no additional DC side protection required:AC side protection requires max 20 A per blanch draft 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(9511-405-1733 WWVV.CRENG.CO Peak output power tw 330 315 -- --- CONTRACTOR INFO Max.continuous output power iN 32D 310 • • Nominal grid voltage(L-L) v 24Qspftt-phawCL-L,1W -- 208.single-pha-tLi.)W IQ$MC Microinverter -- --- --- - - - -- -- - --- Easy t0 install Min./Max.grid voltage� v 211}-25{ 183-229 Our newest IQB Series Microinverter5 are the industry's first microgrid-forming'.software- Lightweight and compact with plug- Max.continuous output current A 1.33 1.49 defined microinverters with split-phase an -Pay connectors - - -- - - -- - - - ---- --- ___ �_ ��/� power conversion capability to convert DC power to Nominal frequency Hx BD T AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range ke n� application-specific integrated circuit(ASIC).which enables the microinverter to operate in between Components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with simple two-wire AC short circuit fault current over three ELEMENT ENERGY LLC. digital logic and has superfast response times to changing loads and grid events,alleviating p cycles A- 270 7470 SOUND AVENUE,MATTITUCK, constraints on battery sizing for home energy systems. cabling NEW YORK,11952 Max.unitspsr2OA(LH,bran chcwctat3 12 10 PH:(631)779 7793 High productivity and reliability Total harmonic distortion services@e2sys.com ss <5 Licence-ME-52689 Produces power even when the grid is (MASTER ELECTRICIAN) down' Ovarvaitage class ACport ■ Licence-HI-67461 More than one million cumulative hours AC port backfeed current mA % (SUFFOLK HOME IMPROVEMENT) of testing .. .. Power factor setting tD Part of theEnpFlaseEnergySystem, 1085erlesMicr(yirwertersredefine Class 11 double-insulated enclosure JANET CIAMARICONE ----------- ------- -------------- --- - - - - amid-tied power rac(w(ad)uable) 0B5leedsg_0354pgkg 585 PACIFIC ST,MATTITUCK,NY IQ$Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules PaakeUdreoy % 97A 11952 EnphaseAppmonitoring and analysis testing,enabling an industry-leading __-e -deffi - ---- - software. limited warranty of up to 25 years. C,EC ��� � 97A 96.5 PV SUMMERY Microgrid-forming f�mttime power consumption mw 33 25 SYSTEM SIZE = • Complies with the latest advanced grid (KWDc) STC 400 X 30 2.000 support PTC SYSTEM SIZE _376.7 X 30 = 1.301 • Remote automatic updates for the Am6i�trarge -40°C to 65'C(-40'F to t49'F) td Relative hu range latest grid requirements mlty ^9e 4%to 10005(condensing) (KWAC) 9.600 @240 • Con urable support DC connector type 8tiubli MC4 MODULES 30 CANADIAN SOLAR fig to PPo a wide range 9 CS6R-40OMS-HL of grid profiles Diwrnions(H•W=DY Weight 212 mm(8.3')•175 mm(69")•302 mm(1.2");Li kg(2.43lbs) MICRO-INV.CITY 30 Connect PV modules quickly and easily 108 Series Microinverters are UL Listed MICRO to the 108 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans IN : ENPHASE IQ8MC-72-M-US integrated MC4 connectors. conforms with various regulations when 15472018(UL 1741-SB) --. unuTv LING ISLAND POWER AUTHORITY Approved for we locations;Pollution degree Yes;PD3 [LING installed according to the manufacturer's instructions. Enclosure Class t double-inwlated•corrosion-resistant pdymarb allow" NOTE - - —------- ----- --- --- ------ --- --------- 108 Mksaewenters canrrol he mised together wnh Environ.category;UV arpow"rating fEMA Type 6:cutdoor Previous generations of Erco—micromve t— Rev Description Date (107 Series.IOs series.etc-I m the same sysstnn. A INITIAL DESIGN 4/17l2024 'Meets Ul 1741 only when instaterl wth b System Control.,2 ant 3 Io Gateway s,•qured to change the detault grid CA Rule 21(UL 1741-SA).UL 62109-1,IEEE 15472018(UL 1741-SB).FCC Part 15 Class B.ICES-0003 Class 6,CAN/CSA-C222 NO.107.1-01 profile at the h—of;rstatanon to a,..t n-Iota! Grtli0111d s This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017.NEC 2020.and NEC 2023 section 690.12 and Aumorty having J—diction(Aw)rec[wrer,roms. C221-20t8 Rule 64-218 ra pid shutdown of PV systems for AC and DC conductors when installed according to the narnlAacbux's instructions. 02023 Enpfuw Ewrgy.Ali rights reaervd.Enph—,the•and CC kq-,IO and certain othe,make ratrd at Mlil- Obi DC/AC ratio. PROJECT# 8959 htipalr molt.ssomrtraee.ar1-v.agr-y.:�of•.e,ar.tradnna.�o+Enphase En.rgr.I•K.in trio us and ah.n countries. (0 aoaanalwaYdaananaamesertmded beyond nammal if requredby the uti y. Oarambleetto (3)LJnals wW—vy h.soloealnpiwmwrxs to d•firw the n—bwofn-rorr—t•n pw branch in your ar•a. IOSUC-MC4-DSH-00049-3.0-EN-US-2023-10-18 DATE DRAWN 4117/2024 DRAWN BY E.R SHEET# PV-7.1 TITLE MICROINVERTER SPEC IQ Combiner 4/4C Data S;aeet Enphase Networking MODEL NUMBER IQ Combiner 4 IQ Combiner 4 with 10 Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C1.2 20 t 0.5%) X-IQ-AM1-240-4 and consumption monitoring(t 2.5%).Includes a silver solar shield to match the IQ Battery and 10 System Controller 2 and to X2-10-AM1-240-4(IEEE 1547:2018) deflect heat. --- IQ Combiner 4C 10 Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20 t 0 5%) THESE DRAWINGS ARE SUBJECT TO X-10-AM1-240-4C and consumption monitoring it2-5sl Includes Mobite Connect cellular modern(CELLMODEM-MI-06-SP-05),apiug-and-piny COPYRIGHT PROTECTION BY US LAW. Q Combiner 4/4 C The IQ Combiner 4/4C with IQ Gateway and X2-IQ-AM!-240-4C(IEEE 1547:2018) industrial-grade cell modem for systems upto 6D microinverters(Available in the US,Canada,Mexico,Puerto Rico,and the REPRODUCTION IN ANY FORM IS US Virgin Islands,where there is adequate cellular service in the mstallabon area.)Includes a silver solar shield to match the integrated LTE-M1 cell modem(included IQ Battery and IQ System Controller and to deflect heat WRITTEN YFORVAL FROM MCURVATHO TPRIOR WRITTEN APPROVAL FROM CURRENT only with IQ Combiner4C)consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) RENEWA13LESENGINEERINGINC. supported m+croinveriers 106,107,and IQ8.(Do not mix 106/7 Microinverters with IQ8) interconnection equipment into a single Communications Kit Current enclosure. It streamlines IQ Microinverters and COMMS-CELLMODEM-Ml-06 -Includes COMMS-KIT-01 and CELLMODEM-Ml-06-SP-o5 with 5-year Sprint data plan � eis e---------- CELLMODEM-MI-06-SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data plan: storage installations by providing a consistent, CELLMODEM-M1-06-AT-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan Engineering Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240.BR250,and BR260 circuit breakers. 4b Ef40HA5E ' pre-wired solution for residential applications. BRK-IOA-2-240v Circuit breaker•2 pole,10A.Eaton OR210 ` BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton OR215 CURRENT RENEWABLES It offers up to four 2-pole input circuits and BRK-20A-2P-240V Circuit breaker,2 pole.20A.Eaton BR220 ENGINEERING INC. 8RK-i5A-2P-24OV-6 Circuit breaker.2 pole,15A,Eaton BR2158 with hold down kit support 1760 CHICAGO AVE SUITE Eaton BR series busbar assembly. BRK-20A-2P-24ov-8 Circuit breaker,2pole,20A,Eaton BR2200 with hold down kit support J-13 RIVERSIDE CA 92507 Y PHONE (951)-405-1733 XA-SOLARSHIELD-ES Replacement solar shield for 10 Combiner 4;4C WW N CRENG.CO XA-PLUG-120-3 Accessory receptacle for Paver Lane Canter in 10 Combiner 4/4C(required for EPLC-01) CO NTRACTOR I N FO -- X-!Q-NA-HD 125A Hold-down kit for Eaton circun breaker with screws Consumption monitoring CT A pair of 200A split core parent transformers Smart (CT-200-SPLITJCT-200-CLAMP) ELECTRICAL SPECIFICATIONSalmn Includes 10 Gateway for communication and control Includes Mobile Connect cellular modem Ong `Continuous duty (CELLMODEM-M1-06-SP-05),included only with System voliage 120i240VAC,60 Hz CZ SYSA ! IQ Combiner 4C Eaton BR series bulbar rating 125A Max core nuous current raging 65A ELEMENT ENERGY LLC. includes solar shield to match Enphase IQ Battery 7470 SOUND AVENUE,MATTITUCK, aesthetics and deflect heat Max.continuous axrent Failing(input from PV'SWrage`t 64A NEW PORK,11952 • Supports Wi-Fi,Ethernet,or cellular connectivity Max.fuse/circuit rating(output) 90A PH:(631)779 7993 services@e2sys.com • Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(no included) Licence-ME-52689 Provides production metering and consumption Ma) total branch circuit breaker rating(mputl 80A of distributed generation 95A with iO Gateway breaker ncluded (MASTER ELECTRICIAN) monitoringLicence-HI-67461 IQ Gateway breaker IOA or 15A rating GE/Siemens/Eaton included (SUFFOLK HOME IMPROVEMENT) tProduction metering CT 200A solid core pre-installed and wired to I0 Gateway Simple MECHANICAL DATA JANET CIAMARICONE X-IQ-AMt-240-4C Mounts on single stud with centered brackets Dmxenswns(WxHzD) 37.5 orn x 49-5 rstt x 16.8 cm(14.75 in x 19-5 in x 6.63 in).Height is 53.5 im(21.06 in)with mounting brackets. 585 PACIFIC ST,M ATTI TU CK,NY X240-AM1-240-4C(IEEE 15472018) Supports bottom,back and side conduit entry Weight 7 5 kg(16 5lbs) 11952 �. Allows up to four 2-pole branch circuits for 240VAC Ambient temperature range -40-C to+46-C(-40aF to 115"17) PV SUMMERY plug-in breakers(not included) Cooiinq Natural convection plus heat shieie SYSTEM SIZE 80A total PV or storage branch circuits Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycar ionate construction (KWDC) STC 400 X 30 =12.000 Wife sizes 20A to 50A breaker inputs.14 to 4 AWG copper conductors PTC 376.7 1 X 1 30 =11.301 Reliable 60A breaker branch input:4 to 110 AWG copper conductors SYSTEM SIZE _ 9 600 @240 • Main lug combined output 10 to 2/0 AWG copper conductors (KWAC) •Neutral and ground 14 to 1/0 copper conductors L40DULES 30 CANADIAN SOLAR • Durable NRTL-certified NEMA type 3R enclosure Always follow local code requirements for conductor sizing. CS6R-40oMS-HL MICRO-INV.QTY 3D Five-year limited warranty Altitude Up to 3,000 meters(9,842 feet) MICRO • Two years labor reimbursement program coverage tNTERNET CONNECTION OPTIONS ONG ISLAND POWER AUTHORITY INVERTER ENPHASE IQSMCWER AUT HORITY included for both the IQ Combiner SKU s ---`— '-- ---------- ----------- -- UTILITY UL listed Integrated Wi-Fi IEEE 80211b/g/n UPA) • X-IQ-AMl-240-4 _ Ceiiuiar CELLMODEM-M1-06-SP-05,CELLMODEM-Mt-06-AT-05(415 based LTE-Mt cellular modem).Nate that an Mobile Connect X2-IQ-AMl-240-4 and X2-IQ-AM1-240-4C comply with cellular modem is required for all Enphase Energy System installations X2-I0-AMl-240-4(IEEE 1547:2018) IEEE 15472018(UL 1741-SB,3r'Ed) Ethernet Optional,IEEE 802-3,CatSE(o Cat6)UTP Ethernet cable(no included) Rev Description Date COMPLIANCE A INITIAL DESIGN 4/17/2024 Compliance,IQ Combiner CA Rule 21(UL 1741-SA) IEEE 15472018-UL 1741-SO.3-'Ed(X2 l0-AM1-240 4 and X2-IQ-AMl-240-4C) CAN/CSA C22.2 No 1071,Title 47 CFR,Pan 15,Class B.ICES 003 PROJECT# Production metering.ANSI C12.20 accuracy class 0.5(PV production) 8959 Leo E N P H A S E Consumption metering accuracy class 2 5 DATE DRAWN 4/17/2024 To learn more about Enphase offerings,visit Compliance,IQ Gateway UL 60601 IiCANCSA 22 2 No 67010-1 p g �I)Rha =AID DRAWN BY ER IQ-C-4-4C-DS-0103-EN-US-12-29-2022 S 2022 Enphase Energy All rights reserved Enphase.the Enphase logo,IC Combiner 4/4C,aria other times are trademarks of Envhase Energy,Inc Data subiea to change IQ-C-4-4C-DS-0103-EN-US-12-29-2022 SHEET It PV-7.2 TITLE COMBINER SPEC /.fir IRONRIDGE XR Rail' Family XR RaifR' Family The XR Rail R Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar is Not AltNays Sunnydesign loads,while minimizing material costs. Depending on your location,there is an XR Rail W, to match. Over their lifetime. solar panels experience countless THESE DRAWINGS ARE SUBJECT TO extreme weather events. Not just the worst storms in years, * i COPYRIGHT PROTECTION BY US LAW. but the Worst Storms In 40 years. High winds Capable Of - REPRODUCTION IN ANY FORM IS ripping panels from a roof. and snowfalls weighing EXPRESSLY FORBIDDEN WITHOUT PRIOR i WRITTEN APPROVAL FROM CURRENT enough to buckle a panel frame. RENEWABLES ENGINEERING INC. XR Rails" are the structural backbone Current preventing these results.They resist uplift. XR10 XR100 XR1000 4enewables protect against buckling and safely { X810 is a sleek,low-profile mounting XR100 Is a residential and commercial XR1000 is a heavyweight among Engineering and efficiently transfer loads into the rail,designed for regions with light or mounting rail.tt supports a range of solar mounting rails.H's built to handle buildingstructure.Their superior no snow.It achieves spans up to 6 feet, wind and snow conditions.while also extreme climates and spans up to 12 r SU p CURRENT RENEWABLES spanning capability requires fewer while remaining light and economical maximOng spans up to 10 feet feet for commercial applications. ENGINEERING INC. ... 1760 CHICAGO AVE SUITE roof attachments, reducing the 6'spanning Capability 10'spanning capability 12'spanning Capability J-13,RIVERSIDE CA 92507 number of roof penetrations Moderate load Capability Heavy load capability Extreme bad capability PW�CRENIG 051733 • Clear&black anodized finish Clear&black anodized finish Clear anodized finishCO and the amount Of I Internal splices available - Intemal splices available Internal splices available CONTRACTOR INFO installation time. ° Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.' Values are a 13 EZSYS� based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. ELEMENT ENERGY LLC. v-_-•.. ' _„u,. _. -_ 7470 SOUND AVENUE,MATTITUCK, • ., NEW 19 PH:(631)31)779 779 7993 Licence-ME-52669 Force-Stabilizing Curve 90 (MASTER ELECTRICIAN) _ Licence-HI-67461 Sloped roofs generate both vertical and lateralt I forces on mounting rails which can cause them to t 20 (SUFFOLK HOME IMPROVEMENT) bend and twist.The curved shape of XR Rails` None " is specialty designed to increase strength in both 140 XR10 XR100 XR1000, JANET CIAMARICONE directions while resisting the twisting.This unique feature ensures greater security during extreme 160 585 PACIFIC ST,MATTITUCK,NY weather and a longer system lifetime. " ' 90 11952 PV SUMMERY 120 SYSTEM SIZE 20 -" (KWDC) STC 400 X 30 = 2000. 140 : PTC 376.7 1 X 1 30 = 7.301 160 SYSTEM SIZE 9.600 Q240 (KWAC) CANADIAN SOLAR 90 MODULES 30 CS6R-40OMS-HL 30 MICRO-INV.QTY 30 . 160 =+ MICRO : ENPHASE IQ8MC-72-M-US INVERTER Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials UTILITY ONG ISLAND POWER AUTHORITY 90 LI PA) XR Rails`are IronRidge°offers All XR Rails'are made of 6000-series 40 compatible with a range of tiff leg aluminum alloy,then protected with an 160 FlashFoota and options for flat anodized finish.Anodizing prevents surface A other pitched root root mounting and structural Corrosion,While also providing 80 160 Rev Description Date attachments. applications. a more attractive appearance. 120 160 d'. A INITIAL DESIGN 4/17/2024 - -- ------- -Tac,*s meanr to be a smplAied span chart for convw_ng general mi capaWkses.Use approver certmcauor letters for acts:oesgn guaance PROJECT# 8959 DATE DRAWN 4ry74 r i DRAWN BY E.R SHEET# PV-7.3 TITLE RAIL SPEC /ram IRONRIDGE QuickMOunP Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home,solar attachments THESE DRAWINGS ARE SUBJECT To must be dependable for the lifetime of the rooftop- COPYRIGHT PROTECTION BY US LAW Due to recent innovations,many asphalt shingles REPRODUCTION IN ANY FORM Is EXPRESSLY FORBIDDEN WITHOUT PRIOR have bonded courses-A mount that protects without a _ � WRITTEN APPROVAL FROM CURRENT ff 4 the need to pry shingles can really speed things up. • • • RENEWABLES ENGINEERING INC. Halo UltraGrip*(HUGI is here to respect the roof- Current Its Halo is a cast-aluminum barrier that encases the Rf'.11t@WdeS UltraGrip,our industrial-grade-foam-and-mastic Engineering seal.This allows HUG to accelerate the installation - process and provide the utmost in waterproofing CURRENT RENEWABLES again.Hit the rafter9 Good to 90. WI the rafter"Try it r • ENGINEERING INC. protection.Give your roof a HUG.' When • you • on • - or -• 1760 CHICAGO AVE SUITE Only '•Structural Screws are needed. to deck mount ft. 3.RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.CRENG.CO Muni-Tiered Waterproofing CONTRACTORINFO HUGS utilizes a multi-tiered Stack of - — 9MVonents to provide revof„ticiriarY Trusted Strength & Less Hassle inc protection.The Halo cast- ratsed-perimeter foundation the UitraGnp base—a roam- Structural capacities of HUG"were reviewed in "'aSbc Seal combination that many load directions,with racking rail running water intrusion by adhering E S YS with the shingle surface cross-slope or up-slope in relation to roof pitch. Hai, For further details,see the HUG certification ELEMENT ENERGY Of the 7470 SOUND AVENUE,MATTIATTITUCK, Ll-- - •, prodk`, � letters fOf attaClllf3g t0 rafters and deClClflg. NEW YORK,11952 PH:(631)779 7993 •""' ""~`" services@e2sys.com IronRidge designed the HUG,in combination Licence-ME-52689 UltraGrip Seal Technology r with the RD Structural Screw to streamline (MASTER ELECTRICIAN) Licence-HI-67461 HUG al design that us a state-of-the-e installs,which means the following: ar,sea:design that uses a unique ,. , foam-and-mastic combination.The pj (SUFFOLK HOME IMPROVEMENT) foam-backed adrlesve provides an • No prying shingles entirety new flashing system that No roof nail interference JANET CIAMARICONE conforms and adheres to every nook 25-Year Warranty No pilot holes necessary 585 PACIFIC ST,MATTITUCK,NY and cranny of composition shingles. Ftoouc'guaranteed free 11952 f,A,ng gaps and shingle step-downs - ed impwng defects_ No sealant(in most cases) up10 118 ,r height) �: • No butyl shims needed . PV SUMMERY SYSTEM SIZE(KWDC) STC 400 X 30 =12.000 PTC 376.7 X 30 =11.301 Attachment SYSTEM SIZE _ g.600 @240 • • • • • - (KWAC) MODULES 30 CANADIAN SOLAR -- - _ _ •� CS61R­400MS-HL MICRO-INV.OTY 30 MICRO INVERTER ENPHASE IQ8MC-72-M-US Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to UTILITY LONG ISLAND POWER AUTHORITY Mount HUG to the root saner-,the roof ed HUG has been and certified for the UL 441 Section UL 2703 mechanical LIPA) RD(rafter-or-deck)oth with Shidww alal Screw.wThe RD tested and rated to compliance with 27"Rain Test"and and bonding Triple ���R�'� • - swcwral screw ar,cnors HUG to Vi root support 1004(Ibs)of the International TAS 100(A)-95 requirements.See 0% With an EPOM SP.allrlg WaSfIL'f COftlpletlflg Rev Description Date UL 2703,441(27) the stack of waterprooi barriers.See uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual A )NITIAL DESIGN 4/17/2024 lnwwk TAS 100(A)-95 backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. ACINF. j- [DRAWN ROJECT# 8959 •23 IronRidge.Inc.All rights rcs�ed.Visit www.ir-patents.com tor patent inforrination.Version • ATE DRAWN 4/17/2024 BY E.R HEET# PV-7.4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. Hayward.CA 94545 28357 Industrial Blvd Hayward,CA 94545 R O N R I D G E 1-800-227-9523 I R O N R I D G E 1-800-227-9523 IronRidge.com IronRidge.com Attn:Corey GeigerhCOO,IronRidge Inc The parameters and adjustments allowed in the span tables are defined as the following: Date:September 7 .2021 Re:Structural Certification and Span Tables for the IronRidge Flush Mount System 1 The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1 5-1,P 9 Y THESE DRAWINGS ARE SUBJECT TO 2. Wind speed shall conform to ASCE 7-16 Fig.26.5-1 B for Risk Category 11 and applicable state&local COPYRIGHT PROTECTION By IS LAW P 9 ( 9 Y ) PP REPRODUCTION IN ANY FORM IS This letter addresses the structural performance and code compliance of IronRidge`s Flush Mount System. The county/city amendments to the IBC. No special wind topographic features are included and both topographic EXPRESSLY FORBIDDEN WITHOUT PRIOR contents of the letter shall be read in its entirety before applying to any project design.The Flush Mount System is a coefficient(Kr.)and wind ground elevation factor(Ke)are taken as 1.0. WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface PV modules are supported by extruded aluminum XR Rails 3. Snow load used in the span tables is the ground snow and shall conform to ASCE specified Fig. 1 and Current applicable state&local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the and secured to the rails with IronRidge mounting clamps.The XR Rails are side mounted to a selected roof format of a flat roof snow. it shall first be converted to a ground snow following the local building code/ ; enewablQs attachment with 3/8'stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables. No special snow conditions are considered Engineering that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding.retention,or ponding snow. No rain-on-snow surcharge load is 4 components are shown in Exhibit EX-0015 considered.The span tables do not apply to buildings which are intentionally kept below freezing.kept lust CURRENT RENEWASLES above freezing,Or unheated. ENGINEERING INC. 1760 CHICAGO AVE SUITE The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: PH RIVERSIDE-1 92507 P P q 9 9� PHONE (Bs,1-aos-T733 listed below,for the load conditions and configurations tabulated in the attached span tables. WWW CRENG Co (a)For ground snow no greater than 42psf-Ss s 2 Og for Site Class A,B,C.&D CONTRACTOR INFO ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:SS<1.0g for Site Class A. B C. &D -- 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:S.<_1.5g for Site Class A.B,C,&D. • 2020 Building Code of New York State(BCNYS-2020. Published in November 2019) • 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in 92 in IN Report SEAOC(Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients(GCp). Roof zones comprising each group along with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. EZSYS' The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point.shall ELEMENT ENERGY LLC. the respective loads and configurations listed, covering wind exposure categories B,C,&D. roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load 7470 SOUND AVENUE,MAT(TUCK, &configuration condition from the span tables,Or 36". NEW YORK,11952 ASCE 7-16 for gable&hip roof profiles, and roof slopes of 8`to 45''. The tabulated spans are applicable when the PH:(631)779 7993 followingCOndItIOnS are met: services@e2sys com 7. Allowable span length in the charts may be multiplied by a factor of 1 08 if the rails are continuous over Licence-ME-52689 a minimum of three spans. (MASTER ELECTRICIAN) 1. Span is the distance between two adjacent roof attachment points(measured at the center of the Licence-HI-67461 attachment fastener). 8 No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements (SUFFOLK HOME IMPROVEMENT) a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans or the outer 2/3 of end spans JANET CIAMARICONE 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system).Spans are calculated b) BOSS Splice can be installed at any location within a span based on 2 rail systems.and conservatively deemed acceptable for 3 rail systems 585 PACIFIC ST,MATTITUCK, NY 9 Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded If 11952 3 The underlying roof slope..measured between the roof surface and horizontal plane.is 80 to 450 such conditions are encountered contact support@ironridge.com PV SUMMERY SYSTEM SIZE(K WDC) STC 400 X 30 =12 000 4. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured PTC 376 7 x 1 30 =111 301 from grade,does not exceed 30 feet. SYSTEM SIZE g.600 9240 (K WAC) MODULES 30 CANADIAN SOLAR 5 A clearance from the underside of the array to the roof surface of 2"minimum shall be provided and the CS6R 40OMS-HL MICRO-INV.OTY - 30 height of the array.the distance from the module top surface to the roof surface(defined as h2)..shall not MICRO ENPHASE IQ8MC-72-M-US exceed 10"_ INVERTER UTILITY ONG ISLAND POWER AUTHORITY LI PA) 6 Module length and area shall not exceed the maximum values listed on the respective span tables. 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Rev Description DateA INITIAL DESIGN a(nizoza Mount Installation Manual and other applicable standards for the general roof construction practice PROJECT# 8959 Z 2021 IronRidge,Inc. NY Flush Mount System Certification Letter-1 C 2021 IronRidge.Inc. NY Flush Mount System Certification Letter-2 DATE DRAWN 4/17/2024 DRAWN BY E.R SHEET# PV-7 5 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd /` I RON RI DGE I RON RI DGE Hayward,CA 94545 Hayward,CA 94545 1-800-227-9523 1-800-227-9523 IronRidge.com IronRidge.com 10 Systems using CAMO module clamps shall be installed with the following guidance The span tables provided In this letter are certified based on the structural performance of IronRldge XR Rails only with no a) For single module installations(orphan modules)using modules with a length greater than 67 5 CAMO clamps shall not be installed in regions that experience ground snow loads of 70psf and greater Such consideration of the structural adequacy of the chosen roof attachments, PV modules.or the underlying roof supporting scenarios are shown by asterisks in the applicable span tables members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the THESE DRAWINGS ARE SUBJECT TO b) CAMO will function within a module's design load ratings Be sure the specific module being used with aforementioned system components in regards to the applied or resultant loads of any chosen array configuration COPYRIGHT PROTECTION S LAW REPRODUCTION IN ANY FORM IS S CAMO meets the dimensional requirements shown in the figure below and that the module selected is EXPRESSLY FORBIDDEN WITHOUT PRIOR suitable for the environmental conditions of a particular project WRITTEN APPROVAL FROM CURRENT CA-New RENEWABLES ENGINEERING INC Sincerely. P1 NG XV �0 2 0 21 .0 9.0 7 ,��G�/Cep Current LU 1 Jr :4S, 1 6 Renewables Engineering R CURRENT RENEWABLES _ 7 HOFf55tOT�t�� ENGINEERING INC. RUnle C M 1760 CHICAGO AVE SUITE X=i.2-2-2mm -- J-13.RIVERSIDE CA 92507 y=15-4Omm PHONE.(951)-405-1733 Gang Xuan, PE WWW CRENG CO — Senior Structural Engineer CONTRACTOR INFO x ---------- =igme 1:CAill Abals Aw Dnnensronal Requirements rM Span values for Exposed and Edge module conditions,as defined below,are included in the attached span r c .• g tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge CZSYS� modules shall be the lesser of the following two: (1)The span value for the Exposed or Edge module condition; (2)The span value determined by site wind speed and ground snow load.Additionally, irrespective of the lesser ELEMENT ENERGY LLC span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage 7470 SOUND AVENUE,MATrITUCK, NEW YORK,11952 limitation detailed in note 9 of page 2 shall apply to the respective condition. PH (631)779 7993 services[ole2sys com Licence-ME-52689 1. Exposed Module conditions: (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) A module Is defined as Exposed(per Section 29.4.4 of ASCE 7-16)if the distance from any of its free edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge.rake.or JANET CIAMARICONE hip)is greater than 0.5h(h Is ASCE defined building height)AND if the distance from Its free edge to any 585 PACIFIC ST,MATTITUCK,NY other adjacent array or panel is greater than 4 feet. 11952 PV SUMMERY The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed SYSTEM SIZE STC 400 X 30 =12000 Modules. (KWDC) PT-- 376.7 X 1 30 =11.301 SYSTEM SIZE 9.600 �240 (KWAC) 2. Edge Module conditions: rKWAC)MODULES 30 CANADIAN SOLAR CSISR-400MS-HL A module is defined as an Edge Module when its distance from any side of the module to Its facing MICRO-INV CITY 30 MICRO ENPHASE 108MC-72-M-US perimeter roof edge(such as eave, ridge,rake.or hip)is less than 2 times the height of the array(2h2) INVERTER where h2 is measured from the roof surface to the to surface of the module UTILITY LING ISLAND POWER AUTHORITY P LI PA) The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. Additionally.. if the roof edge is the eave or ridge.only the rail nearest to that roof edge shall be considered Rev Description Date for this span adjustment A INITIAL DESIGN 411712024 PROJECT# 8959 r 2021 IronRldge Inc. NY Flush Mount System Certification Letter-3 2021 Iron Ridge Inc NY Flush Mount System Certification Letter-4 DATE DRAWN 4/17/2024 DRAWN BY ER SHEET# PV-7 6 TITLE CERTIFICATION ENPHASE y - �;Tr _ IQ8MC Microinverter Our newest I08 Series Microinverters are the industry's first microgrid-forming`,software- Easy to install defined microinverters with split-phase power conversion capability to convert DC power to Lightweight and compact with plug- AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary and-play connectors application specific integrated circuit(ASIC),which enables the microinverter to operate in Power line communication(PLC) grid-tied or off-grid modes.This chip is built in advanced 55 nm technology with high-speed between components digital logic and has superfast response times to changing loads and grid events,alleviating constraints on battery sizing for home energy systems. Faster installation with simple two-wire cabling High productivity and reliability Produces power even when the grid is down' More than one million cumulative hours Part of the Enphase Energy System, Q8 Series Microinverters redefine of testing IQ8 Series Microinverters integrate with reliability standards with more than one Class II double-insulated enclosure the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Optimized for the latest high-powered Enphase App monitoring and analysis testing,enabling an industry-leading PV modules software. limited warranty of up to 25 years. Microgrid-forming Complies with the latest advanced grid support / CERTIFIED Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily I08 Series Microinverters are UL Listed Configurable to support a wide range to the I08 Series Microinverters that have as PV rapid shutdown equipment and of grid profiles integrated MC4 connectors. conforms with various regulations when Meets CA Rule 21(UL 1741-SA)and IEEE installed according to the manufacturer's 1547:2018(LIL 1741-SB) instructions. Note: 108 Series Microinverters cannot be mixed together with previous generations of Enphase microinverters 'Only when installed with 10 System Controller 2 meets UL 1741, (107 Series,t06 Series,and so on)in the same system. 02023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at https://enphase.com/trademark-usage-quideti"s are trademarks of Enphase Energy,Inc.in the US and other countries. Data subject tD change. 108 MC-MC4-DSH-00049-2.0-E N-US-2023-09-11 IQBMC Microinverter INPUT DATA(DC) UNITS 108MC-72-M-US Commonly used module pairings w 260-460 Module compatibility To meet compatibility,PV modules must be within the maximum input DC voltage and maximum module I listed below. Module compatibility can be checked at htttps://enphase.com/installers/microinverters/calculator. MPPT voltage range v 25-45 Operating range v 18-58 Minimum/Maximum start voltage v 22/58 Max.input DC voltage v 60 Max.continuous operating DC current A 14 Max.input DC short-circuit current A 25 Max.module IK A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA(AC) UNITS IGBMC-72-M-U3 @240 VAC IGOMC-72-M-US @203 VAC Peak output power VA 330 315 Max.continuous output power VA 320 310 Nominal grid voltage(L-L) v 240,split-phase(L-0,180° 208,single-phase(L-L),120' Min./max.grid voltage' v 211-264 183-229 Max.continuous output current A 1.33 1.49 Nominal frequency Hr 60 Extended frequency range Hr 47-68 AC short circuit fault current over three cycles Arms 2.70 Max.units per 20 A(L-L)branch circuit 3 12 10 Total harmonic distortion % <5 Overvoltage class AC port III AC port backfeed current mA 18 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading...0.85lagging Peak efficiency % 97.38 97.23 CEC weighted efficiency % 97.00 96.50 Nighttime power consumption mw 28 25 MECHANICAL DATA UNITS Ambient temperature range -40'C to 65°C(-40°F to 149`F) Relative humidity range 4%to 100%(condensing) DC connector type StAubli MC4 Dimensions(H-W•D);Weight 212 mm MY)•175 mm(6.9")•30.2 mm 0.2"}1.1 kg(2.43 Ibs) Cooling Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class 11 double-insulated,corrosion-resistant polymeric enclosure Environ.category',UV exposure rating NEMA Type 6;outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.Seethe compatibility calculator at https://enphase.com/installers/microinwrters/Calcuiator. (2)Nominal voltage range can be extended beyond nominal if required by the utility 108MC-MC4-DSH-00049-2.0-EN-US-2023-09-11 (3)Limits may vary.Refer to local requirements to define the number of mloroinverters per branch in your area. IRONRIDGE Flush Mount System Iron.Ridge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous -approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PIE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Mass A Fire Rating � Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects. .t�► UL 27'03 Listed System 29-Year `warranty Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. X,R1O .Rail XA1G'O Aaiil XR1000 Raii svnd'e'd splices P � 00",A A iow-profile mcunting rail The ultimate residential A heavyweight mounting }ail rails use interrai splices for regions with light snow.` solar mounting rail. rail for commercial projects. for seamless connections t 8' spanning capability 8'spanning capability t' • 12'spanning capability , Self-drilling screws Moderate load capability Heavy load capability � . Extreme load capability ° Varying versions for rails Clear and black finish Clear and black finish Clear anodized finish , Forms secure bonding UFIOS �__. sIq>PeT Sleeves Grvfu ing U igs micrvinve'rtsf KAS Universai Fastening Objects Snap onto the UFO to turn ys to Mount ails or FGs to XR bond modules to rails. into a bondsd snd clamp aquipmant ground. Rams. > Fully assembled & 4ubed Bonds modules tc rails , LcTJ profile , Bonds devices to raids • Single, uriversal size Sized to match modules - Single tcal installaticr, - flit comes assembled • Clear and black finish 3 Clear and black tiniish a I Acunts in any direction , Listed to Ut-2703 PashFocU condutt Mount BorxIiiing Hardwam ' J / Flash and mount XR Mails Flas d mount conduit, - esign for rapiZ l Bond and attach XR Rails with superior waterproofing. ut, or junction boxes, attachment. to roof attachments. Twist on Cap easy& nsfail` - Twist-on Cap eases install SQci.ire rail rnnnertinns 3 T& square Bolt options Wind-driven rain;tested - 'Mind-driven rain tested Slot for vertical adjusting Nut uses 7/1 S" socket Mill and black finish ° Secures 3/an or 1"conduit Clear and black finish ,assembled and lubricated - Design Assistant NABCISF''Certified Tiraining Go from rough layout to fully Earn; free continuing education credits, engineered system. For free. while learning more about our systems. PreliminaryTechnical *%r- CanadianSolar Information Sheet 1W H i Ku6 (All-Black) ALL BLACK MONO PERC 380 W -- 405 W CS6R-380 1 385 1 390 1 395 1 400 1 405MS-H L MORE POWER 25 Industry Leading Product Warranty on Materials Years and Workmanship* Module power up to 405 W 405 Module efficiency up to 20.7% 25 ' Linear Power Performance Warranty* Years 0 Lower LCOE&system cost V year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% *Subject to the terms and conditions contained in the applicable Canadian Solar L,mited warranty Statement-Also this 25-year limited product warranty is available only for prod. Comprehensive LID/LeTID mitigation ucts installed and operatirg on residential rooftops in certain regions technology, up to 50%lower degradation --- - ---.................- MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2015/Quality management system =R� ; Better shading tolerance ISO 14001:2015 i Standards for environmental management system V ISO 45001:2018/International standards for occupational health&safety PRODUCT CERTIFICATES* MORE RELIABLE IEC 61215/IEC 61730/CE/INMETRO UL 61730/JEC 61701/IEC 62716 Take-e-way Minimizes micro crack impacts oyE C�U �® 'The specific certificates applicable to different module types and markets will vary, and therefore not all of the certifications listed herein will simultaneously appiy to the cLi Heavy snow load up to 7000 Pa, products you order or use.Please contact your local Canadian solar sales representative wind load up to 5000 Pa* to confirm the speak certificates available for your Product and applicable in the regions in which the products will be used. ............I............. _........................................ ..__.... CSI SOLAR(USA)CO., LTD.is committed to providing high quality solar photovoltaic modules,solar energy and battery storage solutions to customers.The compartywas recognized as the No.1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight •Pending testing confirmation For detailedinformation. Survey.Over the past 20 years,It has successfully delivered over 67 GW please refer to the Installation Manual of premium-quality solar modules across the world. _............. .. CSI SOLAR(USA)CO.,LTD. 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94597, USA I www.csisolar.com/na I service.ca@csisolar.com ENGINEERING DRAWING(mm) CS6R-40OMS/I-V CURVES A A Rear View Frame Cross Section A-A 14 14 13 r__ _. 13 A A 12 Gran6nq Hole I10 10 9 a Mauntap HNe i 7 6 s 5 I 4 4 2.-------- ___-______._-_ 2. 1 Mounting Hole - 0, 5 10 1520 2s 30 35 40 45 SO ss 60 s 10 15 20 25 30 35 40 45 50 55 60 ■ 1000w/m` 5•c ■ ( ■ itoo wnM 2s•c ■ ❑ ■ 6ao wmr 45-C ■ ■ 40ownrc 6s•c • + 200 wim' ELECTRICAL DATA STC* MECHANICAL DATA CS6R 380MS 38SMS 39OMS 395MS 40OMS 40SMS Specification Data Nominal Max.Power(Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp)30.0 V 30.2 V 30A V 30.6 V 30.8 V 31.10V Cell Arrangement 108[2 X(9 X 6)] Opt.Operating Current(Imp)12.69 A 12.77 A 12.84 A 12.91 A 12.99 A 13.07 A 1722 x 1134 x 35 mm Open Circuit Voltage(Voc) 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V Dimensions (67.8 x 44.6 x 1.38in) Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 21.3 kg(47.0 Ibs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 mm tempered glass with anti- reflective coating Operating Temperature -40"C-+85`C Frame Anodized aluminium alloy, Max.System Voltage 1500V(IEC/UQ or 1000V(IEC/UL) J-Box IP68,3 bypass diodes Module Fire Performance TYPE 1 (UL 61730 150OV)or TYPE 2(UL 61730 Cable 4 mm'(IEC),12 AWG(UL) 1000V)or CLASS C(IEC 61730) Max.Series Fuse Rating 25 A Connector T6 or MC4 series Application Classification Class A Cable Length 1550 mm(61.0 in)(+)/ Power Tolerance 0-+10 W (Including Connector) 850 mm(33.5 in)(-)* 'Under Standard Test Conditions(STQ of irradiance of 1000 W/rrr,spectrum AM 1.5 and cell tempe- Per Pallet 30 pieces rature of 251C. Per Container(40'HQ) 780 pieces •For detailed information,please contact your local Canadian Solar sales and technical representatives. ELECTRICAL DATA I NMOT* CS6R 380MS 38SMS 39OMS 395MS 40OMS 405MS TEMPERATURE CHARACTERISTICS Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Data Opt.Operating Voltage(Vmp)28.1 V 28.3 V 28.4 V 28.6 V 28.8 V 29.0 V Temperature Coefficient(Pmax) -0.34%/°C Opt.Operating Current(Imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A Temperature Coefficient(Voc) -0.26%/°C Open Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/'C Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A •Under Nominal Module Operating Temperature(NMOT),irradiance of 800 W/m-spectrum AM 1.5, Nominal Module Operating Temperature 42 t 3'C ambient temperature 20°C,wind speed 1 m/s. PARTNER SECTION •The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement CSI Solar Co.,Ltd.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. CSI SOLAR(USA)CO.,LTD. June 2022 1 All rights reserved PV Module Product Datasheet v1.5C25_F23J2_NA !L-J" 'ENPHASE. m 108MC Microinverter Our newest IQ8 Series Microinverters are the industry'sfirst microgrid-forming*,software- Easy to install defined microinverters with split-phase power conversion capability to convert DC power to Lightweight and compact with plug- AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary and-play connectors application specific integrated circuit(ASIC),which enables the microinverter to operate in Power line communication(PLC) grid-tied or off-grid modes.This chip is built in advanced 55 nm technology with high-speed between components digital logic and has superfast response times to changing loads and grid events,alleviating constraints on battery sizing for home energy systems. Faster installation with simple two-wire cabling 7 Enphase High productivity and reliability Produces power even when the grid is 5_ down' More than one million cumulative hours Part of the Enphase Energy System, IQ8 Series Microinverters redefine of testing I08 Series Microinverters integrate with reliability standards with more than one Class II double-insulated enclosure the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Optimized for the latest high-powered Enphase App monitoring and analysis testing,enabling an industry-leading PV modules software. limited warranty of up to 25 years. Microgrid-forming . ® Complies with the latest advanced grid support LCERTIFIED Remote automatic updates for the L WEN latest grid requirements Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed Configurable to support a wide range to the I08 Series Microinverters that have as PV rapid shutdown equipment and of grid profiles integrated MC4 connectors. conforms with various regulations when Meets CA Rule 21(UL 1741-SA)and IEEE installed according to the manufacturer's 1547:2018(UL 1741-SB) instructions. Note: IQ8 Series Microinverters cannot be mixed together with previous generations of Enphase microlnverters •Only when installed with IQ System Controller2 meets UL 1741. (I07 Series,I06 Series,and so on)In the same system. 2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at https://enphase.com/tmdemark-usage-quidelines are trademarks of Enphase Energy,Inc.in the US and othercountrles. Data subject to change. I08MC-MC4-DSH-00049-2.0-EN-US-2023-09-11 ,t\ IQ$MC Microinverter INPUT DATA(DCY UNITS Commonly used module pairings W I 260-460 Module compatibility To meet compatibility,PV modules must be within the maximum input DC voltage and maximum module I listed below. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 25-45 Operating range 11 18-58 Minimum/Maximum start voltage v 22/58 Max.input DC voltage v 60 Max.continuous operating DC current A 14 Max.input DC short-circuit current A 25 Max.module I. A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit Peak output power VA 330 315 Max.continuous output power VA 320 310 Nominal grid voltage(L-L) v 240,split-phase(L-L),180" 208,single-phase(L-L),120" Min./max.grid voltage 3 V 211-264 183-229 Max.continuous output current A 1.33 149 Nominal frequency Hz 60 Extended frequency range Hz 47-68 AC short circuit fault current over three cycles Arms 2.70 Max.units per 20 A(L-L)branch circuit 3 12 10 Total harmonic distortion % 5 Overvoltage class AC port III AC port backfeed current mA 18 Power factor setting 10 Grid-tied power factor(adjustable) 0.85 leading...0.85lagging Peak efficiency % 97.38 97.23 CEC weighted efficiency % 97.00 96.50 Nighttime power consumption mw 28 25 MECHANICAL DATA UNITS Ambient temperature range -40"C to 65"C(-40"F to 149°F) Relative humidity range 4%to 100%(condensing) DC connector type Staubli MC4 Dimensions(H x W.D);Weight 212 mm MY).175 mm(6.9")•30.2 mm(1.2");1.1 kg(2.43lbs) Cooling Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure Environ.category;UV exposure rating NEMA Type 6;outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at httPs://enphase.com/installem/microinverters/Calculator. (2)Nominal voltage range can be extended beyond nominal If required by the utility. ICBMC-MC4-DSH-00049-2.0-EN-US-2023-09-11 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. r'. ;"I ___., _ _ ___ _ -. a`:,-='".fir; �_ � - ` ' - _ _ __- • -_�,�:.- x - z , T w ' one��=.._- •-, -- [ -_._•`___ ._ iron-Ridge builds the strongest mounting system for pitched roofs in solar. Every component has been tasted to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified. code compliant and backed by a 20-year warranty. Strength Tested - PE Certified a All components evaluated for superior p p �� Pre-stamped engineering letters structural performance. available in most states. Chess A Farce Bating •- .,; Des�gn Assistant Certified to maintain the fire resistance -- Online software makes it simple to rating of the existing roof. - create, share, and price projects. Mire system and component's meet �'r�liCe the protection 0"fgrad by C art a• - eyves:: eke xi'le .sue7w s rd. corric,e^hors. XF 10 P.a51 XATOO Psi:1 X;;!000 A.aLn 8®'rlded SpAcee ,ram_ = ` =?J'`_ '. me unting Tail The-ultimate residential A hea,,cryeicn, mcunt rig All rails us6 mtesnai spiices for regions with light snow solar mounting rail. rail for commerclai Qrc ects iG' seamless connections o' spanr•ir-g capability S'spanning capability = 12'spans piny capabrli-y sell-drilling screws ' Moderaia icad capability _ Heavy load capability r' E-.Creme load capability Varyirg.Vers;cis to rails Clear and black finish "%Clear and black finish Clear anodized finish Forms secure bonding Z3cippeir Vetev!es 'Go-cituirlding Lmgs cP�an er2e�Kam tiT,,rersal Faste;ring Cb ects snap on-to the UFO to turn ys to Mount Mis or Fvs to XR t—criC. mltodues tho rails a bonded sf,d clarrr e ui?Jmerft ground'. Ralrs. ' Fully assembled & tubed Bonds mccluies to rails ' t c`3i1 prof ile - Bcnds devices to *ails ' v;y glc, Sr i`l�rsa sizesized tc match. modules - Single 4 .ri 'n 3 •laticr_. - K3t,canes assernti;led L3r� 1-.. zJ J' .S_aS Clear and black `r sSs^ ' Clear and blare iiitiSri _ jrt ijPit� it �y direr irr �� v�G t� 'V^27�i5 Uondluail ir3ouutl Nair -am Flash and mount XR Rails Flas d mount conduit, - esign for rapid rail Bond and attach XR Rails with superior waterproofing. �tr unction boxes. attachment. to roof attachments. Tvuist on Cap eases-bsfaii - Twlist-or. Cap eases install - SpcL_ire rail cOnnertinns - T& Square Solt options Mind-driven rain tested - Wind-driven rain tested - Slot for vertical adjusting - glut uses 7/16"socket Mill and black finish - Secures 3/4"or 1"conduit , Clear and black finish - Assembled and lubricated NAECEP-Oartifled TTalning Ce from rough layout to fully Earn free continuing education credits, engineered system. For free. ,. - while learnir'g more ,aiDrjut our systems. -�-- •. ;: .. Preliminlank aTechn•icai � - - CanadianSolar f. Information Sheet t, HiKu6 (All=Black) ALL BLACK MONO PERC 380 W - 405 W C56R-380 1 385 E 390 1 395 1 400 1 405MS-HL MORE POWER25 Industry Leading Product Warranty on Materials t Years t and Workmanship* Module power up to 405 W SOS bV Module efficiency up to 20.7% 25 = Linear Power Performance Warranty* \ZYears Lower LCOE&system cost 111 year power degradation no more than 2% Subsequent annual power degradation no more than 0-55% `subject cc the terms and conditions contained in the applicable Canadian Solar Limited Warranty Statement.Also ibis 25-year limited product warranty is available only for prod- Comprehensive LID/LeTID mitigation ucts installed and operating on residential rooftops in certain regions. technology,up to 50%lower degradation .. ..........................__...................................................... ............. MANAGEMENT SYSTEM CERTIFICATES* 150 9001.2015/Quality management system a Better shading tolerance f50 14001:2015/Standards for environmental management system 150 45001:2018/fnternational standards for occupational health&safety ✓ PRODUCT CERTIFICATES* MORE RELIABLE IEC 61215 y IEC 61730/CE/INMETRO UL 61730/IEC 61701/IEC 62716 Take-e-way Minimizes micro-crack impacts v ' ;E �sA„sC E �� �-f me specific cerifiates applicableto different module types and markers will vary, and therefore not all of the certifications listed herein will simultaneously apply cc the -{.}. Heavy snow load up to 7000 Pa, products you order or use.Please contact your local Canadian solar sales representative l I� wind load up to 5000 Pa* w confirm the specific certificates available for your Product and applicable in the regions in which the products will be used. ...........................................-...................................................-..................... ....... CSI SOLAR(USA)CO.,LTD.is committed to providing high quality solar photovoltaic modules,solar energy and battery storage solutions to customers.The company was recognized as the No.1 module supplier for quality and performancelprice ratio in the IHS Module Customer Insight "Pending testing confirmation.For detailed information. Survey.Over the past 20 years,a has successfully delivered over 67 GW please refer to the Installation Manual. of premium-quality solar modules across the world. . . ........ ... ....... .. . ........ .... ........................ .. ........ ....... ............... CSI SOLAR(USA)CO.,LTD. 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94597, USA I wvvw.csisolar.com/na I service.ca@csisolar.com EKdINEERING DRAWING(mm) CS6R-400MS I-V CURVES A A Rear View Frame Cross Section A-A 14 14 13 A-A 12 6-05 Gmunding Hole 35 to 1------- ------- 9 ------- -------- 'a-I X9 H.e 71 4 3 2 Mounting Hole vo-: 5 10 15 20 25 30 35 40 45 50 55 60 5 10 15 20 25 30 35 40 45 50 55 50 1000 WI.- 5'c 800%vim, zs'c IN ElI T0 600 W 45-C N 400 Wl- 65,c im Sl 200%-hlm- ELECTRICAL DATA STC* MECHANICAL DATA CS6R 38WAS 3851VIS 39OMS 39SMS 400MS 405MS Specification Data Nominal Max.Power(Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type M ono-crysta[line Opt.Operating Voltage(Vmp)30.0V 30.2V 30.4 V 30.6 V 30.8 V 31.0 V Cell Arrangement 108[2 X(9 X 6)] Opt.Operating-Current(Imp)12.69 A 12.77 A 12.94 A 12.91 A 12.99 A 13.07 A 1722 x 1134 x 35 mm Dimensions "p n Circuit Voltage(Voc) 36.0V 36.2V 36AV 36.6V 36.8V 37.011 (67.8 x 44.6 x 1.38in) ----------- Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 1177 A 13.85 A 1193 A Weight 21.3 kg(47.0 lbs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 imm tempered glass with anti- __ ._reflective Operating Temperature -40°C-+85°C ------- Frame Anodized aluminium alloy, Max.System Voltage 1500V(IECIUQ or 1000V(IEC/UL) ]-Box IP68,3 bypass diodes Module Fire Performance TYPE 1 (UL61730 1500V)or TYPE 2(UL 61730 Cable 4 mm2(IEC),12 AWG(UQ 1 000V)or CLASS C(IEC 61730) ---- Connector T6 or MC4 series Max.Series Fuse Rating 25 A Cable Length 1550 mm(61.0 in) Application Classification Class A (Including Connector) 850 mm(33.5 in) Plower Tolerance 0-+__10'W under Standard Test Conditions(STC)of irradiance of 1000 War,spectrum AM 1.5 and cell tempe- Per Pallet 30 pieces rature of 25'C. Per Container(40'HQ) 780 pieces -For detailed information,please co nract you r local Canadian�oIa�sal a_nd technical representatives. ELECTRICAL DATA I NMOT* C56R 380MS 385IVIS 39OMS 395MS 400M. S 405M5 TEMPERATURE CHARACTERISTICS Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Data Opt,Operating Voltage(Vmp)28.1 V 28.3 V 28.4 V 28.6 V 28.8 V 29.0 V Temperature Coefficient(Pmax) -0.34% 'C Opt.0 eratinq Current(Imp)10.12A 10.19A 10.26A 10.33A 10.39A 10.45A -p Temperature Coefficient WOO -0.26%/'C Open Circuit Voltage(Voc) 33.9V 34.1V 34.2V 344V 34.6V 34.7V Temperature Coefficient(Isc) 0.05% *C Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A Under Nominal Module operating Temperature(NMOT),irradiance ofliDo Wtm�speclnrurn AM L Nominal Module Operating Temperature5, -------------42±3°C- ambient temperature 20°C,Wrid speed I m1s. PARTNER SECTION .............. ....................... .............. ................ •The specifications and key features contained in,his clatasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement.CS1 Solar Co.,Ltd.reserves the right to make necessary adjustment to the information described herein at any time without Farther notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. .............................. ................. ....................... .... ....... ....... -......... ............................... CSI SOLAR(USA)CO.,LTD. June 2022 1 All rights reserved PV Module Product Datasheet v1.5C25_F23_J2_NA