HomeMy WebLinkAbout51061-Z • ., R�-�-S 510to I - sate ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED BUILDING CONC CONCRETE DC DIRECT CURRENT POWER—CONDITIONING INVERTER. ALL WORK TO COMPLY WITH SEC11ON R327 OF THE 2020 RESIDENTIAL CODE OF NYS. EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY — RECOGNIZED TESTING EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. ELECTRODE CONDUCTOR GND GROUND. HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PROPERTY LINE Pal POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B). TYPICAL UPS UNINTERRUPT18LE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN OF NE RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY ��c. �V y UL LISTING. �'tQ•�p,OJIAN 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL — LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. W 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE Z BONDED WITH EQUIPMENT GROUND CONDUCTORS. J'F� 105800 A��F 10Np�, VICINITY MAP INDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES Sheet 5 MOUNTING DETAILS Sheet 6 ESS LOCATION 1. ALL WORK SHALL COMPLY WITH THE 2020 NYS Sheet 7 THREE LINE DIAGRAM UNIFORM CODE. Cutsheets Attached 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE. , 3. ALL WORK SHALL COMPLY WITH THE 2020 NYS ARE CODE. MODULE GROUNDING METHOD: ZEP SOLAR 4. ALL WORK SHALL COMPLY WITH THE 2020 BUILDING CODE OF NYS. REV BY DATE COMMENTS AHJ: Southold Town 5. ALL WORK SHALL COMPLY WITH THE 2020 f"' REV A NAME DATE COMMENTS RESIDENTIAL CODE OF NYS. x 6. ALL WORK SHALL COMPLY WITH THE 2020 UTILITY: PSE&G—Long Island EXISTING BUILDING CODE OF NYS. b x x x x x x x x r i � • r � 1 � s ! � � � x � 1 r '� • � � x x x x CONFIDENTIAL- THE INFORMATION HEREIN JOB NUIIBFR J B- ' 119 3081 00 CUSTOMERDESCRIMON: DESIGN: CONTAINED SHALL NOT BE USED FOR THE David Jannuzzi 14.175 KW PV ARRAY Priyanka George �t OF ANYONE IN EXCEPT HOLLEE OR IN NOR Y01�"'"'s 350 Harbor Ln 40.5 KWH ENERGY STORAGE SYSTEM T = 5 L n PART TO 01HEM OUT9DE THE RECIPIENTS ZS Com V4 w Flashin —Insert NY 11935 ORGANIZATION,EXCEPT IN CONNECTION YNTH MoaaEs Cutchogue, THE SALE AND USE OF THE tiMCTIVE (35) Hanwha Q.PEAK DUO BLK ML—GIO+/TS 405 1ESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET REV: DAIS PEREtts9ON of MLA INC Powerwall 3 240V 1707000-25—G 11.5 kW 13.5 kWh 6316801157 COVER SHEET 1 A 5/22/2024 v PITCH:24°(5:12) ARRAY PITCH:24° (5:12) HATCHING INDICATES WIND PRESSURE MP1 AZIMUTH:45 ARRAY AZIMUTH:45 " ZONES. SEE THE .STANDOFF SPACING MATERIAL:Comp Shingle STORY: 2 Stories AND LAYOUT TABLE FOR MORE PITCH:240-(5:12) ARRAY PITCH:240(5:12) INFORMATION. MP2 AZIMUTH:315 ARRAY AZIMUTH:315 MATERIAL:Comp Shingle STORY. 2 Stories PITCH:240(5:12) ARRAY PITCH:24°(5:12) OF NEW r MP3 AZIMUTH:225 ARRAY AZIMUTH:225 �•tP \pp J1AN x/�O,p� MATERIAL:Comp Shingle STORY. 2 Stories PITCH:240(5:12) ARRAY PITCH:240 (5:12) * * MP4 AZIMUTH:225 ARRAY AZIMUTH:225 y MATERIAL:Comp Shingle STORY: 2 Stories t, C� PITCH:241 (5:12) ARRAY PITCH:24°(5:12) (E)1MNEWAY y MP5 - AZIMUTH:135 ARRAY AZIMUTH:135 105800 �� MATERIAL-Comp Shingle STORY: 2 Stories ® AROF SS P�. PITCH:240 (5:12) ARRAY PITCH:24° (5:12) ® MP6 AZIMUTH:45 ARRAY AZIMUTH:45 MATERIAL:Comp Shingle STORY. 2 Stories LEGEND Front Of House TI(E) ULITY METER & WARNING LABEL y.. :.: . .. ... sv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS : :::::" :•::.>i. RELAY .... AUTOMATIC RELAY a DC DISCONNECT & WARNING LABELS ES Ac AC DISCONNECT & WARNING LABELS SV 36"FSB Q DC JUNCTION/COMBINER BOX & LABELS ..'f ENERGY STORAGE SYSTEM FOR STAND lU ALONE OPERATION ° ] DISTRIBUTION PANEL & LABELS Fol LOAD CENTER & WARNING LABELS ' f EXTERNAL DISCONNECT SWITCH .f O DEDICATED PV SYSTEM METER 0Q RAPID SHUTDOWN 0 STANDOFF LOCATIONS y CONDUIT RUN ON EXTERIOR m-- CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED (� '( INTERIOR EQUIPMENT IS DASHED L_"J TOTAL ARRAY AREA (SF): 759 SITE PLAN N TOTAL ROOF AREA (SF): 2341 Scale:1/16" = 1' w E TOTAL ARRAY AREA IS a 32.42 01' 16' 32' PERCENT OF TOTAL ROOF AREA S lm CWDENTIAL— THE INFORMATION HEREIN ao6 NIMIIEr� J B-119 3 0 81 0 0 CONTAINED SHAM NOT BE USED FOR THE David Jannuzzi 14.175 KW PV ARRAY Priyanka George BENMT OF ANYONE EXCEPT MA INC.,NOR MOUBTNG SM M: T . 5 L n SHALL IT BE DISCLOSED IN MOLE OR IN ZS Comp V4 w Flashing—Insert 350 Harbor Ln 40.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S MaoulEs Ctho ue, NY 11935 ORGANIZATION,EXCEPT IN CONNECTION WITH uc g THE SALE AND USE Of THE RESPECV 35 Hanwha # Q.PEAK DUO BLK ML—G10+/TS 405 PAGE NAPE SHEET- REV DALE TESLA EWPMENT. WITIIOUT THE WRITTEN �� ON OF T> u Powerwall 3 240V 1707000-25—G 11.5 kW 13.5 kWh 6316801157 SITE PLAN 2 A 5/22/2024 S1 (N) PV MODULE (E) MOUNTING PLANE (MP) Of NEW), sv TYPICAL PV SIDE VIEW NTS J' 105800 'e sl- PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER INSTALLATION ORDER ZEP ROCKIT OCATE FRAMING MEMBER, MAR ZEP LEVELING FOOT (1) HOLE LOCATION, AND DRILL ZEP ARRAY SKIRT PILOT HOLE. ZEP MOUNTING BLOCK (4) ATTACH FLASHING INSERT TO ZEP FLASHING INSERT (3) (2) MOUNTING BLOCK AND-ATTACH TO FRAMING MEMBER USING LA (E) COMP. SHINGLE SCREW. (1) 2 "MIN. (E) ROOF DECKING (2) INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS 5/16" DIA STAINLESS, LOWEST MODULE SUBSEQUENT MODULES SEALANT EVENLY OVER THE STEEL LAG SCREW ROOF PENETRATION. INSTALL LEVELING FOOT ON TOP (E) FRAMING MEMBER C(4) OF MOUNTING BLOCK & S STANDOFF „ — ' SECURELY FASTEN WITH BOLT. Scale: 1 1/2 — 1 CONFIDENTIAL-THE INFORMATION HEREIN sae NUW J B-119 3 081 00 CONTAINEO SHALL NOT BE USED FOR THE BMT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTDrh David Jannuzzi 14.175 KW PV ARRAY Priyanka George T 5 L n SHALL IT BE DISMOSED IN WHOLE OR IN ZS CompV4 w Flashing—Insert 350 Harbor Ln 40.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS Maouu Cutchogue, NY 11935 ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE 35 Hanwha Q.PEAK DUO BLK ML—G10+/TS 405 TESIA EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME. SI�Er RM. DATI PERMISSION OF MA INC Powerwall 3 r24OV1 # 1707000-25—G 11.5 kW 6316801157 13.5 kWh STRUCTURAL VIEWS 3 A 5/22/2024 �a ,�sptel5e�t>,1t.a Do*owe ASCE 7-18 Fft Cetepmy I TWO Is-I t hem and Sped "t 130 Ft}t898A Bp—cejw, c SaDm28.7 CAMW gar Loot M 30 Td*7-1 lP Spank Dts14t Yfaea9m NP Nmm In LP2 I4P3 IN LP5 W5 ROD" cmq mho cmP s Shbo ft"9*0 cm amp cop 9*0 sbmm ZS Dona Y4 a ZS Omp Y4• Z5 Cwq W■ ZS Cop W■ 7S Cxw W• ZS Orap W■ Aai�B'Mrt fla�iq-bmd p4d6q-kt-t PA*& Not Fbftn-tort! RnVV-bwl pm 24 24 24 24 24 24 SAL-PV Im I19 49 119 152 1S9 SL/ktl:NO-" 20A 2D.9 20A 2OA 208 203 Edpt Zaa adth 44 ft 4.4 R 4.4 ft 44 ft 44 R 4.4 ft A*m* 45 315 225 225 135 45 smile. 2 2 2 2 2 2 . r Ron,ske/4efq w or cc w as'Dc w or cc w Or Dc w or cc wo Dc ��O f NEW cj�� w or oc 2s5 me oc 2a or oc 2r8«5'oc w as•oc w ar oc �PQ J IA N . ��pf Nm. on w2 aril� NP W4 1P5 IP5 * Apow and 2-ft y— w L-bw X-40" s4 d4 94 64 84 s4 L-dnw 24 24 24 24 24 24 L-t"Y-40" 41 N 41 41 H 41 ESSIONP� PmtreR X-spiny 48 a 48 48 48 48 PPat XY-*c w 74 19 15 19 19 19 Pe Y-$oe6p 74 74 74 74 74 74 Patron T-cmtlwr LOW sm9pnd "+to99�d Sm94rtW 5teppardftnew Sm9pmod *waw zm.. :: : ow Promo -2256 -22.58 -22M -22.58 -22.58 -2ZW L d-"X-sue e4 94 54 s4 e4 94 X 24 24 24 24 24 24 L-dee s Y-spo" 41 41 41 41 41 41 Paba t X-*cHp 32 - 32 32 32 32 32 Pam X-Cmum 14 14 14 14 14 14 Patron Y-*ft 74 74 74 74 74 74 Patre't Y-Cmtbm - - - - - - AWd aW Toth :ii•i:i•2r,2.3 ii�2r.2t.J•_Oct:•iirii 20.7r,3(iii! r:i:24$3 i:ii:i{•ii}21.2,3-:•;:i• i:ii•20.2r,3•: . aW Rum -2238 -2258 -22.58 -2259 -2258 -$58 w*cq.X-*ft a4 tK 44 84 a4 84 X 24 24 24 24 24 24 lmd-w Y-90=4 41 41 41 41 41 41 Paw X-Wft 32 32 s2 32 32 32 Patton X-Omtlww 14 14 14 14 14 14 Pcib Y-Spade 74 74 74 74 74 74 Patrdt Y-C num - - - - - L*d SDow-d sto99oed Sto998W Stapp w %Mod Sto99m d Nottc _ 2 XHd*"InApobd and Zme arngw*to 1atd"m SRs�P1mr. �ft PK X to Gum rettrtt ad Y Y d<rt9 tnRrta CONFIDENTIAL—THE INFORMATION HEREIN ace NIlw18ETt: JB-1193081 00 CONTAINED SHALL NOT BE USED FOR THE David Jannuzzi AN 14.175 KW PV ARRAY Priyanka George T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC„NOR MUM SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 350 Harbor Ln 40.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS NY 11935 ORCAN17ATION.EXCEPT IN CONNECTION wnH Moots CutChogue, THE SALE AND USE OF THE RESPECTIVE 35 Hanwho # Q.PEAK DUO BLK ML—G10+/TS 405 TESLA EQUIPMENT. WITHOUT THE WRITTEN mTER: PAGE NAPE SftfET REV DALE PERMISSION OF TESLA INC. Powerwall 3 f240VI # 1707000-25—G 11.5 kW 13.5 kWh 6316801157 UPLIFT CALCULATIONS 4 A 5/22/2024 POWERWALL ER POWERWALL INSTALLATION INFORMATION: WALL TYPE MODEL DIAMETER EMBEDMENTFASTEFASTENERSOPER ESR# UNISTRUT REQUIRED? CORNER WOOD sm WDDD SON&w wo or 1 NA m ❑ No[Z 1. POWERWALLS TO BE INSTALLED PER FASTENER SCHEDULE BASED ON WALL TYPE CoNcr&m CONCRM SC" y,. ,�• �, NA OR Cw AND SITE SPECIFIC CONDITIONS. CDWNM Sol"7m NO wo 2• 0 �7;� NA OR CM2. DO NOT MOUNT BELOW OR ABOVE WINDOWS OF THE SAME STORY. �nN~—a w• 1w 0 ��;�° ' NA 3. IF LOCATION NEEDS TO BE CHANGED, PLEASE CONTACT DESIGN TEAM. wcx M.nKMKCONN 11 Y4• WC NA Na 4. ANY UNUSUAL FRAMING NEAR THE POWERWALL THAT MAY COMPROMISE THE WALL Hfrmm SUZE wo �' , M-4143(BMW NA STRUCTURAL INTEGRITY SHALL BE RELAYED TO THE DESIGN TEAM PRIOR TO INSTALL. SHEET MEXA<scmvs J'' NA m [] ND Q NSTALL 5. WHEN INSTALLING POWERWALL+ THE INVERTER IS A SINGLE UNIT AND CANNOT BE 2. 1 CONCRETE INSTALLER D& CMU NO CHOOSE N—EESSRE FASTENERR BASED CAN BE CONDITIONS. UNIT(S)WALL ARE MOUNTED ON E, AND EASE OF (THE ROUND AND SEISMIC SS (SRA SHORTSTACKED. WHEN INSTALLING A STACKED ARRANGMENT, ONLY ONE POWERWALL+ AND 3. 1TCON RETEE& CMUSESR FASTENER CAN BE USED WHEN UNTT(S) ARE MOUNTED ON THE GROUND AND SEISMIC Ss (SPA AT SHORT ONE ADDITIONAL POWERWALL CAN BE INSTALLED. THE LARGEST STACKING 4. COLD FORMED) IS MINIMUM D 5 GAUGE REQUIRES 3REGI0FASTENERS PER CORNER. BUT NAL WIND SPEED (3—SECOND G1 F)ASTENER IS AT RPER CORNER BELOW °�"BE USED CONFIGURATIONS ALLOWED BY THE MOUNTING BRACKETS ARE 3 POWERWALL UNITS WHEN STEEL STUDS ARE 8 GAUGE OR THICKER OR 1 POWERWALL+ AND 1 POWERWALL UNIT WHEN BOX IS CHECKED DIVERSTTECH PAD ACP24362 IS APPROVED FOR A SINGLE OUTDOOR POWERWALL GROUND MOUNT AND DIVERSITECH PAD ACP36362 IS APPROVED FOR UP TO 2 STACKED USING A POWERWALL+ AND A POWERWALL UNIT OR 2 POWERWALL UNITS POWERWALL_ UNIT WALL Z�OF NEW}' � R aFASTENERS� F�� CR 0-3 pIAN � PER CORNER EXAMPLE >k * ONE FASTENER o o o IN ANY HOLE PER COMER 105800 TWO HERS o 0 0 0 Q IN ANY HOLE FASTT3NER TO WALL AR�FfS 1 Np� PER CORNER PER FASTENER SCHEDULE S � POWERWALL+ WALL BRACKET (N)POWERWALL BRACKET, POWERWALL UNIT NOT SHOWN FOR CLARITY WALL ATTACHMENT: WALL MOUNT SIDE VIEW ONE POWERWALL NTs ATTACHMENT: FRONT VIEW POWERWALL rTTs CONFDENTIAL- THE INFO IWATIOI HERBN im Numim J B-119 30 81 00 CUSTOM DESWTION: ��"` CONTAINEO SHALL NOT BE USED FOR THE David Jannuzzi 14.175 KW PV ARRAY Nyanka George T 5 L n BENEFlT OF ANYONE IXCEPT TESLA INC,NOR MOUNTING SY51QN SHALL IT BE DISCLOSED IN WHOLE OR IN zS Comp V4 w Flashing—insert 350 Harbor Ln 40.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S Cutcho ue, NY 11935 ORGANIZATION,EXCEPT IN CONNECTION WITH g THE SALE AND USE OF THE RESPECnVE (35) Hanwha # O.PEAK DUO BLK ML—G10+ TS 405 PAGE NAME SHEET REY DATE TEsIA EQUIPMENT.WTnNouT THE wtaTTEN IN►attE� 6316801157 5 A 5 22 2024 PENISSION OF TESLA INC. Powerwall 3 240V 1707000-25—G 11.5 kW 13.5 kWh MOUNTING DETAILS t r 1 `,.'4"-5� `�''� � ff�Jy�"�+�7f �11` �,_ '�'�.��''+1' J�, r� f .,, `��*,.ry�1�• __ ,r', Z-2 ,� +r .. � l I � 1.�` F Lx�1: y�-�Y n.a ti r FF"t! _ �:'.'�► 4'yJ d ems,` r f�i . - - s .'.A . Jr� /' -F«J' �` S• wi.'r'S li, ..-�t,J �s * FI �.�I 49 �� + �iT r� �j Y f(• ��~ a ''+' ' , 1 {}{� �•L•� - '� <�� �- � '+ __ -,090 _T ,fir ,rC '" e .r 4 r fil •' 1 { +F r ..t'��' �„� _ Fes_ ^ � - ` 1 • ,r 'Y' t 11 i�1 f ,lI` '�• -, 'r, F I i �^�` I '1., + � , -24 i •� '�' — � w N. �a • R r'[.. 1 �1I�!rtr - • r � •� •.-, `,.Y�_� ,a�e"'T.3.. 1' � —04 + ' 'h' , r , � ,'`'CI �1- � + •1 - 'r•, p•� t- �-� y•ri- r ' 't4 I,�,Y f a S '4 c4 { , �'"_ 1 t � .. ` ` ' a � '� A ` 1 1 Y �. ( 1. �' 1 � Jy' F . 1 � 'l I �Sk ' � r '�', � -� y•. � - r ' • * �•y + .y - I 1- �t/J,�Fi � i f l?"';. n �� r � f � k` ..fit.' � k` .a.� a i t s - i 1t 11/' CONFIDENTIAL INFORMATION 1: :T . CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE David Jannuzzi 14.175 KW PV ARRAY Priyanko George BENEFIT OF ANYONE1MOUNTING SYSTEM: SHALL IT BE DISCLOSED 1 OR IN • 1 Flashing—Insert / • • 4' STORAGE •• 1 OTHERS OUTSIDE • ORGANIZATION, CONNECTION li •• ue, NY 35 THE SALE 1 USE 1 Hanwho # Q.PEAK 1 / C 1 4/ 7 DATE: EQUIPMENT,TESLA 1 PERMISSIONPAGE NAME-- 1 INVERTER: LOCATION . , l 1 , '• • 1 1 111 • • .�0 (E) WIRING BACKUP GATEWAY AC DISCONNECT (N) 225A LOAD CENTER Tesla Powerwall 3 EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. E-stop WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED A B C 12,wire p TO #6 SOLID BARE COPPER. 11 200A 2P 200A 60X2P 9 8 4 2 1 S1 F 6 T TO 120/240V 200A 2P SINGLE PHASE Tesla Powerwall 3 UTILITY SERVICE E-stop 12v r've E 60A 2P (E) LOADS 5 3 1 S4A (E) 200A 1 S4B DISTRIBUTION 3 1 S5A PANEL F1 © 1 S58 EXTERNAL DISCONNECT SWITCH T 60�2P 7 H POWERWALL r------------------•-•- ---- - - - - -------- i Rj'2v Emergency Stop Button (E-Stop)Rapid Shutdown Initiation Device per Article 690.12(C) of the NEC • Disconnecting Means as defined in Article 100 of the NEC Connection to generation sources with 12V, 1A communication wire L——————————————————————————————————- rC'CONDUCTOR Ref Oty Description Ref Type Qty Size (AWG, Cu) EGC (AWG, Cu) Conduit Isc (ADC) Imp (ADC) Product String Module per MCI per Voc• Vmp Mounting 1 200A Main Circuit Breaker, 2-Pole, 24OV, 1OkAIC 1 PV Wire 2 #10 SBC #06 3/4" EMT 11.17 10.83 Ref Ref String String (VDC) (VDC) Plane A 1 Tesla #1841000-01-C: Back-up Gateway 3.0 NA for PW 2 THWN_2/THWN 2 #10 #10 3/4" EMT 11.17 10.83 S1 5 2 256.08 186.95 MP4 1 Disconnect; 200A, 240Vac, Fusible, NEMA 3R: 2P, 3W, Lockable 3 THWN-2/THWN 2 #08 #10 3/4" EMT 22.34 21.66 D S2 3 1 153.65 112.17 MP3 1 Ground/Neutral Kit; 200A General, Heavy Duty(DG, DH), NEMA 1, 3R S3 9 3 460.94 336.51 MP5 e e r •� 2 Fuse; 200A, 25OV, Class RK5: Time Delay, 200kA I.R. S4A 6 2 307.30 224.34 MP1 Size (AWG) Min EGC Conduit92" PVC Length Imp Vmp S4B 6 2 307.30 224.34 MPi 1 Class R Fuse Kit Ref Type Qty AWG, Cu ft AAC VAC E 1. GROUND NEUTRAL BOND TO BE COMPLETED IN SERVICE EQUIPMENT (A) (Cu) (Al) ( ) (Cu) ( ) ( ) ( ) S5A 3 1 153.65 112.17 MP2 3 Breaker, 60A/2P, 2 Spaces 2. CONDUIT RUNS MAY BE CONDENSED DUE TO SITE CONDITIONS AND/OR 4 THWN-2 3 J06 #04 #10 PVC Jacketed MC 5ft 48 240 S5B 3 1 153.65 11 2.1 7 MP6 INSTALLATION EASE. ALL CONDUIT FILL DERATES AND PROPER CALCULATIONS C 1 Eaton #BRP20NC20DR: Load Center (BR Convertible), 200A, NEMA 3R, 10 kAIC, 1P, 5 THWN-2 3 #O6 #04 #10 PVC Jacketed MC Sft 48 240 HAVE BEEN COMPLETED PER NEC CHAPTER 9, TABLE 4. 20 Spaces, 120/240 V 3. SOLAR SHUTDOWN DEVICE TO BE INSTALLED FOR SYSTEM RAPID SHUTDOWN D i Powerwall 3 [240V]#1707000-25-G 11.5 kW /13.5 kWh 6 THWN-2 3 #2/0 #4/0 #06 2" PVC 2ft - 240 (RSD) IN ACCORDANCE WITH ARTICLE 690 OF THE APPLICABLE NEC. 7 THWN-2 3 #06 #04 #10 PVC Jacketed MC 1" EMT 50ft - 240 4. CONDUIT TYPE CAN CHANGE DUE TO SITE CONDITIONS AND WILL FOLLOW E 1 Powerwall 3 [240V]#1707000-25-G 11.5 kW/13.5 kWh THE NEC REQUIREMENTS FOR THAT CONDUIT TYPE. F 2 JUNCTION BOX, 4 STRING 8 THWN-2 3 #2/0 #4/0 #06 2° PVC 2' PVC 2ft - 240 6 Teslo MCI, 650V, 12A 9 THWN-2 3 #2/0 #4/0 #16 2° PVC 2° PVC Sft - 240 c 6 Tesla MCI, 650V, 12A Main Panel Rating (E) 200A Hanwha # Q.PEAK DUO BLK ML-G1O+/TS 405: H 1 Powerwall 3 [240V] # 1707000-25-G 11.5 kW/13.5 kWh Main Breaker (E) 200A PV Module, 405W, 376.3WPTC, ZEP, Block Rating Frame, MC4, 1000V I 1 UL 508 Emergency Stop Device - NEMA 4X General Notes DC Ungrounded Qty 35 Inverters Voc 45.34 Panel Number Vmp 37.39 Meter Number 98361040 Isc and Imp are in the DC Conductor Table Service Entrance Underground CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-1193081 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE David Jannuzzi 14.175 KW PV ARRAY Priyanka George T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 350 Harbor Ln 40.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTSORG MODULES C U t C{l 0 U @, NY 11935 THE ASALE¶AND USE EOF PT ITHE RESPECTIVE N CONNECTION �TM (35) Hanwha # Q.PEAK DUO BLK ML—G10+/TS 405 g TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: PERMISSION OF TESLA INC. INVERTER: 631 68011 57 7 A 5 22 2024 Powerwall 3 240V 1707000-25—G 11.5 kW 13.5 kWh THREE LINE DIAGRAM / / el Location: Label WARNING:PHOTOVOLTAIC POWER SOURCE "• Location: '• • • ,_ Code:B 'WARNING ,_ ;'_ 'WARNING ELECTRIC NEC 690.31.G.3 SHOCK. NEC HAZARD ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS ' 1 13 THE DC CONDUCTORS OF THIS Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE PHOTOVOLTAIC DC LOAD SIDES M AY BE ENERMEMENINGIZED UNGROUNDED AND DISCONNECT '- ••_ IN THE OPEN POSIIts] MAY BE ENERGIZED NEC 690.13.13 Label Location: Label • • PHOTOVOLTAIC POINT OF ■ MAXIMUM POWER- , INTERCONNECTION Per Code: POINT CURRENT(Imp)�A • ••- :WARNING: ELECTRIC SHOCK MAXIMUM POWER- HAZARD. DO NOT TOUCH POINT VOLTAGE(Vmp)�VNEC 690.53TERMINALS.TERMINALS ON MAXIMUM SYSTEM BOTH THE LINE AND LOAD SIDE VOLTAGE(Voc)_v MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT POSITION. FOR SERVICE CURRENT(Isc)_A DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT MAXIMUM AC Label Location: OPERATING VOLTAGE V WARNING ' Code:Per ELECTRIC SHOCK HAZARD 691 IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED Label Location: MUMIJAMUNGOMMINE1.1 (POI) IOWN 19EDOAN9 ENERGIZED CAUTION DUAL POWER SOURCE Per •.- NEC SECOND SOURCE IS 1 5.12.13.3 PHOTOVOLTAIC SYSTEM Label • • WARNING (DC) (CB)Per •• Label ELECTRICAL SHOCK HAZARD • • DO NOT TOUCH TERMINALSCEC 690.13.13 CAUTION ' ■• TERMINALS ON BOTH LINE AND Per Code: LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFEDNEC 690.64.13.4 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • WARNING '• Per ..- INVERTER OUTPUT Label • • CONNECTIONNEC 1 • PHOTOVOLTAIC AC PO DO NOT RELOCATEDisconnect DISCONNECTPer C••- THISODEVCERRENTConduit NEC 690.13.13 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IQ Interior Run Conduit Label AC A ` '• OPERATING CURRENT � Load ■_ Code: MAXIMUM AC OPERATING VOLTAGE VNEC ' Label90.54 (POI): Point of Interconnection SC BACKUP LOAD CENTER CAUTION • .Label Location: Label Location: '_ • _ TRI POWER SOURCE Per Code: NEC 408.4 184 SECOND SOURCE IS PHOTOVOLTAIC. NEC SYSTEM , THIRD SOURCE IS ENERGY STORAGE SYSTEM Label • • CAUTION DO NOT ADD NEW LOADS Per ••": Label Location: NEC ' (MS') Per ..- THIS EQUIPMENT FED BYNEC 705.12.B.2.3.c Label • • MULTIPLE SOURCES.TOTAL CAUTION RADEV COES,EXCOLUDINGUMA NNT THIS PANEL HAS SPLICED FEED Per •'' SUPPLY OVERCURRENT DEVICE, THROUGH CONDUCTORS. NEC 312.8.A(3) SHALL NOT EXCEED AMPACITY LOCATION OF DISCONNECT AT ENERGY OF BUSBAR. STORAGE BACKUP LOAD PANEL "• Location:Label NOMINAL ES;S VOLTAGE 12CV240V . Location: CAUTION Per Code: DUAL POWER SOURCE Per ..- CIRCUIT FROM ESS: 32A Per 1. 7(D) label t• •- marked in field SECOND SOURCE ISNEC 705.12(B)(3) ARC FAULT CLEARING ENERGY STORAGE SYSTEM TIME FROM ESS: 67mS Label Location: DATE OF CALCULATION_ ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHTPer •• Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALLPer •• Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALLPer •• Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED INSLDEPerCode: (` Disconnect Backup Load Center (MSP): Main Service Panel StandardLabel • Gateway 3 Tesla Gateway 3 controls connection to the grid in a Powerwall system,automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption,time-based control,and backup operation. Performance Model Number 1841000-01-y AC Meter Revenue accurate(+/-0.5%) Specifications Nominal Grid Voltage 120/240 V AC Communication CAN Grid Configuration Split phase User Interface Tesla App Grid Frequency 60 Hz Backup Transition Automatic disconnect for seamless backup Continuous Current 200 A - ---- ------- -------- -- - Rating Overcurrent 100-200 A Maximum Supply 22 kA with Square D or Protection Device Service entrance rated Eaton main breaker Eaton CSR, BWH,or BW,or Short Circuit Current Square D QOM breakers 25 kA with Eaton main _—_— breaker' Internal Panelboard 200 A IEC Protective Class Class I 8-space/16 circuit breakers ---- ----- -------------- Eaton BR,Siemens QP,or Overvoltage Category Category IV Square D HOM breakers 'Only Eaton CSR or BWH main breakers are 25 kA rated __--_ rated to 10-125A Warranty 10 years Environmental Operating Temperature -20°C to 50°C(-4°F to 122°F) Specifications Operating Humidity(RH) Up to 100%,condensing ---------------------- -------- -- ------- ---- ------------------ Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Certifications UL 67, UL 869A, UL 916, UL 1741 PCs, Information —_ --- CSA 22.2 107.1, CSA 22.2 29 — Emmissions FCC Part 15, ICES 003 Mechanical Dimensions 660 x 411 x 149 mm Specifications (26 x 16 x 6 in) Weight 16.4 kg (36 Ib) T 9 S L R ------- --------------- Mounting options Wall mount 660 mm o �411 mm� �mm Gateway 3 Datasheet 2023 PV HAZARD CONTROL SYSTEM BIPV PV HAZARD CONTROL SYSTEM I GENERIC PV ARRAY UL 3741 REPORT DATE 01-27-23 UL 3741 REPORT DATE 01-27-23 Tesla Inverter Based PVHCS, Consisting of Tesla Inverters,Tesla MCI and other PV RAPID SHUTDOWN ARRAY PV RAPID SHUTDOWN ARRAY listed components to create the system WARNING:To reduce the risk of injury, read all instructions. WARNING:To reduce the risk of injury,read all instructions. PV HAZARD CONTROL EQUIPMENT AND COMPONENTS PV HAZARD CONTROL EQUIPMENT AND COMPONENTS Function Manufacturer Model No. Firmware Versions Certification Standard Function Manufacturer Model No. Firmware Versions and Checksums Certification Standard and Checksums PVRSE Mid Circuit Tesla MCI-1,MCI-2 N/A UL 1741 PVRSE Inverter,Powerwall+,or 7.6 kW:1538000' V4,CEA4F802 Interrupter(MCI) Powerwall 3 Tesla 3.8 kW:1534000' V4,FF7BE4E1 UL 1741,UL 1998, 7.6 kW:1538000' V4,CEA4F802 7.6 kW:1850000' V4,CEA41=802 PVRSS/PVRSE Inverter,Powerwall+,or Tesla 3.8 kW:1534000' V4,FF7BE4E1 UL 1741, 1998 11.5 kW: 1707000' V1,Ox3282A1 Powerwall 3 7.6 kW:1850000' V4,CEA4F802 PVRSS/PVRSE 11.5 kW:1707000' V1,0x3282A1 Mid Circuit Interrupter(MCI) Tesla MCI-1,MCI-2 N/A UL 1741 PVRSE PV Module Tesla SR60T1,SR72T1, N/A UL 61730 The PVHC PV modules must be listed by a NRTL to UL 1703 and/or UL 61730-1 and UL 61730-2(excluding Class 0 SR72T2,SR72T3R PV Modules and Class I). PVHCS Initiator Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC 690.12 N/A The PV mounting system must comply with one of the following: (PV Inverter) requirements. PV Mounting System Listed by NRTL to UL 2703 and rated for use with the specific PV modules noted above. PVHCS Initiator Emergency stop device(NISD)-Listed"Emergency Stop Button"or"Emergency Stop UL 508 or UL 60947 The non-certified combinations of mounting and PV modules shall be evaluated for loading,mounting and (Powerwall+,Powerwall 3) Device"or"Emergency Stop Unit". Parts 1,5-1 and 5-5 grounding per the NEC and other applicable installation codes. The following PV connectors may be used to connect to the Tesla MCIs: PVHCS Initiator On/Off Enable switch located on Powerwall 3,when labeled as Rapid Shutdown initiator per Staubli type PV-KST4/611-UR or type PV-KST4-EV02(male), (Powerwall 3) NEC 690.12 requirements UL 1741 PV Connectors Staubli type PV-KBT4/611-UR or PV-KBT4-EV02(female), • Staubli Branch Socket PV-AZB4 and Branch Plug PV-AZS4, Applies to variations of this part number with suffix of two numbers and one letter. Connectors evaluated by an NRTL for intermatability with the connectors above. Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVHCS Initiator Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC N/A PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. (PV Inverter) 690.12 requirements. PVHCS Initiator Emergency stop device(NISD)-Listed"Emergency Stop Button"or"Emergency Stop UL 508 or UL 60947 Parts PVHCS INSTALLATION REQUIREMENTS (Powerwall+,Powerwall 3) Device"or"Emergency Stop Unit". 1,5-1 and 5-5. Max System Voltage 600 VDc PVHCS Initiator On/Off Enable switch located on Powerwall 3,when labeled as Rapid Shutdown initiator UL 1741 (Powerwall 3) per NEC 690.12 requirements PVHCS Maximum Circuit Voltage(Array Internal Voltage After Actuation) 165 VDc(cold weather open circuit) 'Applies to variations of this part number with suffix of two numbers and one letter. Max Series-Connected Panels Between MCIs: 10 Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. OTHER INSTALLATION INSTRUCTIONS PVHCS INSTALLATION REQUIREMENTS 1.An MCI must be connected to one end of each series string or mounting plane sub-array string. Max System Voltage 600 VDc 2.Verification that MCIs are installed with 10 or fewer modules between MCIs shall be documented for inspection, by voltage PVHCS Maximum Circuit Voltage(Array Internal Voltage After Actuation) 165 VDc(cold weather open circuit) measurement logs and/or as-built string layout diagrams. OTHER INSTALLATION INSTRUCTIONS 3. For PV Inverter:The PVHCS initiator(AC breaker or switch)shall be sized and installed in accordance with NEC requirements.The 1.An MCI must be connected to one end of each series string or mounting plane sub-array string. specific part shall be identified on the as-built system drawings. 4. For Powerwall+or Powerwall 3:The PVHCS emergency stop initiator shall have the following minimum ratings:.Outdoor(Type 3R 2.MCIs shall be installed between series connected module combinations such that the PVHC Maximum Circuit Voltage after actuation is no greater or higher), 12V, 1 A,and shall be installed in accordance with NEC requirements.The specific part shall be identified on the as-built than 165V under any circumstances. The installation location coldest anticipated operating ambient temperature shall be used to calculate the PV system drawings. Refer to the Powerwall installation manual for further details. maximum voltage in accordance with NEC 690.7. 3.Verification that the MCIs are installed in accordance with 1)and 2)shall be documented for inspection,by voltage measurement logs and/or as- built string layout diagrams. 4.For PV Inverter:The PVHCS initiator(AC breaker or switch)shall be sized and installed in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. 5.For Powerwall+and Powerwall 3:The PVHCS emergency stop initiator shall have the following minimum ratings:Outdoor(Type 3R or higher),12V, 1A,and shall be installed in accordance with NEC requirements.The specific part shall be identified on the as-built system drawings.Refer to the Powerwall installation manual for further details. T = 5 L n TESR-DS-0451-22 1 T = 5 L n TEPV-DS-0023-22 Q��MPAT�� ROOFING SYSTEM SPECIFICATIONS � GROUND ZEP LEVELING FOOT Listed to UL 2703 Listed to UL 2703 DESCRIPTION PV mounting solution for composition shingle roofs. Part#850-1511 Part#850-1397 Works with all Zep Compatible Modules. Auto bonding UL-listed hardware creates structural and electrical bond. SPECIFICATIONS Designed for pitched roofs. Installs in portrait and landscape orientations. DC WIRE CLIP HOME RUN CLIP Engineered for spans up to 72"and cantilevers up to 24". Listed to UL 1565 Listed to UL 1565 Part#850-1509 Part#850-1510 ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from any \ \� manufacturer certified as"Type 1"or"Type 2". Attachment method UL listed to UL 2582 for Wind Driven Rain. �� � \ i \� /\ ZS Comp supports 50 psf(2400 Pa)front and up to 72 psf(3450 Pa) rear side design load rating for Portrait module orientation per UL 2703. ZS Comp supports 50 psf(2400 Pa)front side and up to 72 psf(3450 Pa) rear side design ARRAY SKIRT I I END CAP load rating for Landscape module orientation. Listed to UL 2703 Listed to UL 2703 Engineered for compliance with ASCE 7-05, 7-10, and 7-16 wind load requirements. Part#850-1608 Part#850-158 (Left) 9 P q Part#850-1568(Right) Zep wire management products listed to UL 1565 for wire positioning devices. ZS Comp grounding products are listed to UL 2703 and UL 467. ZS Comp bonding products are listed to UL 2703. f l MOUNTING BLOCK 1-1 FLASHING INSERT SKIRT GRIP F-1 INTERLOCK Listed to UL 2703 Listed to UL 2703 and UL 2582 for Wind Driven Rain Listed to UL 2703 Listed to UL 2703 Part#850-1633 Part#860-1628 Part#850-1606 Part#850-1613 CAPTURED WASHER LAG HYBRID INTERLOCK Part#850-1631-002 and#850-1631-004 Listed to UL 2703 Part#850-1281 O J T - 5 L n ZS COMP DATASHEET 2 T - 5 L n ZS COMP DATASHEET 3 Powerwall 3 Powerwall 3 Technical Specifications Power Everything System Technical Model Number 1707000-xx-y Powerwall 3 is a fully integrated solar and battery system,designed to accelerate the transition to sustainable energy.Customers Specifications Nominal Grid Voltage(Input&Output)---- --- --- - --------120/240 VAC------- -------- - - - - -- --- can receive whole home backup,cost savings,and energy independence by producing and consuming their own energy while Grid Type - Split phase participating in grid services.Once installed,customers can manage their system using the Tesla App to customize system Frequency 60 Hz behavior to meet their energy goals. Overcurrent Protection Device 60 A_ Solar to Battery to Home/Grid Efficiency 89%1•2 " Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has -------- ------- - - -- - -- -- -- - --the ability to start heavy loads up to 185 A LRA,meaning a single unit can support the power needs of most homes. Powerwall 3 Solar to Home/Grid Efficiency 97.5%3 is designed for mass production,fast and efficient installations,easy system expansion,and simple connection to any electrical Supported Is-landing-Devices Gateway 3,Backup Switch,Backup Gateway 2 service. Connectivity WI-Fi(2.4 and 5 GHz),Dual-port switched Ethernet, Cellular(LTE/4G4) Hardware Interface Dry contact relay,Rapid Shutdown(RSD)certified switch and 2-pin connector,RS-485 for meters AC Metering Revenue Grade(+/-0.5%) i Protections Integrated arc fault circuit interrupter(AFCI),Isolation p. Monitor Interrupter(IMI),PV Rapid Shutdown(RSD)using Tesla Mid-Circuit Interrupters Customer Interface Tesla Mobile App 3,. Warranty 10 years Solar Technical Maximum Solar STC Input - 20 kW Specifications Withstand Voltage_ 600 V DC d5 ' PV DC Input Voltage Range 60-550 V DC PV DC MPPT Voltage Range 60-480 V DC MPPTs 6 Maximum Current per MPPT(1 ) 13 A5 mp --_ - -- Maximum Short Circuit Current per MPPT(I..) 15 A5 Battery Technical Nominal Battery Energy _ 13.5 kWh AC - Specifications Maximum Continuous Discharge Power - 11.5 kW AC _ Maximum Continuous Charge Power 5 kW AC { Output Power Factor Rating 0-1(Grid Code configurable) Maximum Continuous Current 48 A ;»„ Maximum Output Fault Current__- --10 kA - :, Load Start Capability(1 s) 185 A LRA Power Scalability Up to 4 Powerwall 3 units supported 'Typical solar shifting use case. Walues provided for 25°C(77°F),at beginning of life.3.3 kW charge/discharge power. 'Tested using CEC weighted efficiency methodology. 4The customer is expected to provide internet connectivity for Powerwall 3;cellular should not be used as the primary mode of connectivity.Cellular connectivity subject to network operator service coverage and signal strength. 5 Where the DC input current exceeds the MPPT rating,a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A IMP/30 A Isc• 2024 2024 Powerwall 3 Datasheet 2 Powerwall 3 Technical Specifications Powerwall 3 Example System Configurations Environmental operating Temperature__�_ __- ,___ __-20°C to 50°C(-4°F to 122°F)6__ Powerwall 3 with Gateway 3 IOntlona/- Specifications Operating Humidity(RH) _ ___- _ Up to 100%,condensing _-_ _ - - Whole Home Backup I i Storage Temperature -- =onde si 30St (-4°F to 860F),up: %i RH,non-- I-��I condensing,State of Energy(SOE):25%initial I i I --— I I Maximum-Elevation- 3000 m(9843 ft) I - - Solar I - - Environment Indoor and outdoor rated ••••• — � Enclosure Rating _ - NEMA3R Ingress Rating IP67(Battery&Power Electronics) Meter _ IP45(Wiring Compartment) _ _ _ _ Grid Meter socket panel Gateway 3 Load center Pollution Rating PD3 I Operating Noise @ 1 m <50 db(A)typical _n <62 db(A)maximum a Performance may be de-rated at operating temperatures above 40°C(104°F). Backup loads Powerwall.3 Compliance Certifications UL 1642,UL 1699B,UL 1741,UL 1741 SA, UL 1741 SB,UL Information 1741 PCS,UL 3741,UL 1973,UL 1998,UL 9540,IEEE 1547- 2018,IEEE 1547.1,UN 38.3 Powerwall 3 with Backup Switch _ Grid Connection United States Whole Home Backup I \ ► i I Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Backup Switch I I ---- ----- -- ---- -- - - I - -I Seismic _ _ AC156,IEEE 693-2005(high) Solar Fire Testing Meets the unit level performance criteria of UL 9540A Meter Grid Meter socket panel Load center Mechanical Dimensions _ _ 1099 x 609 x 193 mm(43.25 x 24 x 7.6 in) Specifications Weight _ i - 130 kg(2871b) Mounting Options Floor or wall mount = Backup loads Powerwall 3 o 200 0 Powerwall 3 with Backup Gateway 2 Idptlona,— Partial Home Backup I�� I I I Utility Meter I = 1 1099 mm 1 Solar I Main — - - == Breaker == Grid Meter load center Backup Gateway 2 Load center I I 609 mm 9 � Non-essential loads Backup loads Powerwall 3 �mm 2024 Powerwall 3 Datasheet 3 2024 Powerwall 3 Datasheet 8 Fill T = SLn GENERAL NOTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 GD SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.B.2.1) • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PURSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ J—BOX J—BOX J—BOX J—BOX J—Box J—BOX MCI MCI DC- RETROEIT PV MODULES • MCIS ARE LOCATED AT ROOF LEVEL, JUST UNDER THE PV MODULES IN ACCORDANCE WITH 690.12 REQUIREMENTS 1 • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH — NUMBER OF MODULES BETWEEN MCI UNITS = 0-3 — MAXIMUM NUMBER OF MODULES PER MCI UNIT = 3 J—BOX J—BOXI IJ—BOXI J—BOX — MINIMUM NUMBER MCI UNITS = MODULE COUNT/3 MCI *Exception: Tesla (Longi) modules installed in locations where the max Voc for 3 modules at low design temperature exceeds 165V shall be limited to 2 modules between MCIs. PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR T (2)AWG, PV Wire, 600V, Black DC MORE INFORMATION Q. PEAK DUO BLK O PEAK DUO BLK ML-G10+ SERIES ■Mechanical Specification ci ML-G10+ SERIES ocells °531n5am1 _ uep'nmmi Format 74.4in x 41.2in x 1.57in(including frame) (1890 min x 1046 min x 40 min) `"Groun0m9po"°°o"•'°'"'"' Weight 51.8lbs(23.5 kg) F - >sxx mss.,a 35,is3x�ry Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology 385-405 Wp 1132 Cells x•nowmmi Back Cover Composite film 20.5% Maximum Module Efficiency Frame Black anodised aluminium sx:gxs""i Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101 mm x 32-60 mm x 15-18 mm),IP67,with bypass diodes 2- - - - - -Il-,sr lm mini -AoaxrH aril Cable 4mm Solar cable;(+)>_52.2in(1325mm),I-)Z52.2in(1325mm) T_gT0354•lamml Connector Stbubli MC4;IP68 MODEL'.'-Q.PEAK'DUO BLK.ML-GlO+/TS 2 ■ Electrical Characteristics --- --- - - -�-- POWER CLASS. 385 390 395- 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-0 W) Power at MPP' Purlp [W] 385 390 395 400 405 Breaking the 20%efficiency barrier E Short Circuit Current' Isc - [A] 11.04 11.07 11.10 1114 11.17 Q.ANTUM DUO Z Technology with zero gap cell layout E Open Circuit Voltage' Vqc [V] 45.19 45.23 45.27 45.3 45.34 boosts module efficiency up to 20.5 S Current at MPP I °n [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VM [VI 36.36 36.62 36.88 37.13 37.39 Efficiency' [°/] z19.5 219.7 220.0 >-20.2 2!20.5 u'-' A reliable investment �S MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS.NMOT2 Inclusive 25-year product warranty and 25-year linear 1 Power at MPP PIP, [V✓] 288.8 292.6 296.3 300.1 308.8 Warwnty performance warranty. "°°'°"`"°"""' E Short Circuit Current I- [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Vqc [V] 42.62 42.65 42.69 42.72 42.76 Enduring high performance Current at MPP I.- [A] - - -- 8.35-- __---8.41 - _- 8.46 8.51 - - 8.57 Voltage at MPP V-1 [V] 34.59 34.81 35.03 35.25 35.46 Long-term yield Security with Anti LeTID Technology, 'Measurement tolerances P..±3%:Is_;Va±5%at STC:1000 W/m',25±2°C,AM 1.5 according to IEC 60904-3•2800 W/nix•NMOT,spectrum AM 1.5 aceells Anti PID Technology2 and Hot-Spot Protect. Ocells PERFORMANCE WARRANTY- : -PERFORMANCE AT LOW IRRADIANCE - 0o no At least 98%of nominal power F Innovative all-weather technology during first year.Thereafter max. as -- -`- ---------------y 0.5%degradation per year.At w l� Optimal yields,whatever the weather with excellent low-light least 93.5%of nominal power LL +� -+----- - ---- andtemperaturebehaviour. $ up tolOyears.Atleast86%of ni nominal power up to 25 years. w z 4s I 5 of - All data within measurement 90 ¢ I�FL--tIIL-- lIL1 Zep eompatibleTm frame design - tolerances.Full warranties il� U" F a accordance with the warranty4 High-tech black Ze Com atibleTM frame,for improved o B0 terms of the Qcells sales ap g p p p u o as a s xa zs organisation of your respective zoo aoo spo eoo 00o q aesthetics,easy installation and increased safety. YEARS country. IRRADIANCE(W/nil o "Standard terms of guarantee for the 5 Pv companies with the Typical module performance under low inaidlance conditions in q highest production capacity In 2021(February 2021) comparison to SIC condNons(25°C.1000 W/m'). The most thorough testing TEMPERATURE COEFFICIENTS _ programme in the industry Temperature Coefficient of I_ a [%/K] +0.04 Temperature Coefficient of Vol, [3 [%/K] -0.27 0l VVW��11 QCells is the first solar module manufacturer to pass the Temperature Coefficient of P_P y [%/K] -0.34 Nominal Module Operating Temperature NMOT CFi 109±5.4 most comprehensive quality programme in the industry:The (43±3°C) m new"Quality Controlled PV"of the independent certification ■Properties for System Design ol institute TOV Rheinland. Maximum System Voltage Vim, [V] 1000(IEC)/1000(UL) PV module classification Class II ¢ Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 0 See data sheet on rear for further information Max.Design Load,Push/Pull' [Ibs/ft'] 85(4080 Pa)/85(4080 Pa) Permitted Module Temperature -40°F up to+185°F x APT test conditions according to IEC/TS 62804-1:2015,method A(-1500 V,96h) 3 on Continuous Duty (-40°C up to+85°C) Max.Test Load,Push/Pull [Ibs/ft] 128(6120 Pa)/128(6120 Pa) 3 See Installation Manual ■Oualifications and Certificates - UL 61730,CE-compliant, Quality Controlled PV- _ Tl1V Rheinland;IEC 61215,2016. WnPg4a� w IEC 61730:2016, + \A® C U.S.Patent No.9,893,215 C .°Us ` isclar cells) ~°aepOm The ideal solution for: , °.2,02,, ryQOOMPgT2B( ❑o o F Rooftoparras on Rooftop arrays on Tf^^^+ _ % w ❑ ❑ Y I��-1-�� P Y ,o ..*.° USA <epO iou ro residential buildings IIFH, II commercial/industrial buildings Ocells pursues minimizing paper output in consideration of the global environment. Note:Installation instructions must be followed.Contact our technical service for further information on approved installation of this product ���"� Hanwha a CELLS America Inc 400 Spectrum Center Drive.suite 140o,Irvin Ne•CA 92618,USA I TEL 949 748 59 96 1 EMAIL hgc.inqulry@gcells.com I WEB wwwgcet s coin Solar Shutdown Device 1 Technical Specifications The Solar Shutdown Device is a Mid-Circuit Interrupter(MCI) and is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with Powerwall+ or Tesla Solar Inverter. solar array shutdown is initiated by any loss of AC power. Electrical Nominal Input DC Current Rating(IMP) 12 A Specifications Maximum Input Short Circuit Current(Isc) 19 A Maximum System Voltage(PVHCS) 600 V DC RSD Module Maximum Number of Devices per String 5 Performance Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years Environmental Ambient Temperature -40°C to 50°C (-40°F to 122°F) Specifications Storage Temperature -30oC to 700C(-220F to 158°F) Enclosure Rating NEMA 4X/IP65 Compliance Certifications UL 1741 PVRSE, UL 3741, Information PVRSA(Photovoltaic Rapid Shutdown Array) RSD Initiation Method PV System AC Breaker or Switch Compatible Equipment See Compatibility Table below Mechanical Model Number MCI-1 Specifications Electrical Connections MC4 Connector 250 mm ----�l---- Housing Plastic M4 Screw Dimensions 125 mm x 150 mm x 22 mm 650 mm 150 mm M8 Bolt (5inx6inxlin) Weight 350 g(0.77 lb) Nail/ - - -- - -- ---------- Wood Screw Mounting Options ZEP Home Run Clip __ __ .___ ____ M4 Screw(#10) M8 Bolt(5/16") Nail/Wood screw - - -- - - - - - I—I 125 mm� 22 mm UL 3741 PV Hazard Control (and PVRSA) Compatibility Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with Powerwall+or Tesla Solar Inverter and Solar Shutdown Devices.See Powerwall+/Tesla Solar Inverter Rapid Shutdown: Module Selection Based on PV Hazard Control System Listing for guidance on installing other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS (where xxx=405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules' Tesla TxxxH (where xxx=395 to 415 W, increments of 5) Hanwha Q.PEAK DUO BLK-G5 or Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. January 31, 2023 Tesla Solar Shutdown Device 1 Datasheet �R �j ® S ^ 1 Road,Austin,TX P 650 681 681 5100 F 650 681 5101 5101 Version#97.8-1 WS(4) PIL August 8,2024 Certification Letter Project/Job#1193081 Project Address: Jannuzzi Residence 350 Harbor Ln Cutchogue,NY 11935 AHJ Southold Town Tesla Operations Center Bethpage Design Criteria: -Applicable Codes=2020 RCNYS/BCNYS/EBCNYS with 2020 NYSUCS,ASCE 7-16,and 2018 NDS -Risk Category=II -Wind Speed=130 mph(3-s Gust-Vult),Exposure Category C,Directional Procedure for Rooftop Solar Panels -Ground Snow Load=30 psf -MP4:RDL=10 psf,RSL=20.8 psf,PVSL=16 psf -MP5:RDL=10 psf,RSL=20.8 psf,PVSL=16 psf MP6:RDL=10 psf,RSL=20.8 psf,PVSL=16 psf -MP1:RDL=10 psf,RSL=20.8 psf,PVSL=16 psf -MP2:RDL=10 psf,RSL=20.8 psf,PVSL=16 psf -MP3:RDL=10 psf,RSL=20.8 psf,PVSL=16 psf Note: Per IBC 1613.1; Seismic check is not required because Ss=0.175<0.4g and Seismic Design Category(SDC)=B<D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Tesla.Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. OF NEW,,, �Pp JIA N X I AOJ I A Digitally sign to XIAOJIAN XIEDate:2024.0 N XIE 00:43 04—04'0 �s �z 105800 A�O.rr(zs �P� STRUCTURAL ANALYSIS & HARDWARE DESIGN RESULTS SUMMARY TABLES Jobsite Specific D- Design Standard _ _ ASCE 7-16_ Risk Category _ II` _Table 26_9-1 Ultimate Wind Speed V-Ult 130 mph __ __ Fig.26.5-1B Expdsure Category A_ C _ Section 26.7__ Ground Snow Load __ _pg 30.0 psf Table 7-1 .• �- MP Name MP4 MP5 MP6 MP7 MP2 MP3 Roofing Comp Roof Comp Roof Comp Roof Comp Roof Comp Roof Comp Roof 0 Standoff ZS Comp V4 with ZS Comp V4 with ZS Comp V4 with ZS Comp V4 with ZS Comp V4 with ZS Comp V4 with o, Flashing Insert Flashing Insert Flashing Insert Flashing Insert Flashing Insert Flashing Insert N Pitch 24° 241 24° 1 24° 24° 1 24° SL/RLL:PV 16.0 psf 16.0 psf 16.0 psf 16.0 psf 16.0 psf 16.0 psf SURLL:Non-PV 20.8 psf 20.8 psf 20.8 psf 20.8 psf 20.8 psf 20.8 psf Edge Zone Width 4.4 ft 4.4 ft 4.4 ft 4.4 ft 4.4 ft 4.4 ft Standoff Sp.jcing_ d Layout MP Name MP4 MPS MP6 MP1 MP2 MP3 Applied Wind Zone WZ1 WZ1 WZ1 WZ1 WZ1 WZ1 Wind Pressure -15.5 psf -15.5 psf -15.5 psf -15.5 psf -15.5 psf -15.5 psf XSpacing 64" 64" 64" 64" 64" 64" CL X-Cantilever 24" 24" 24" 24" 24" 24" w Y-Spacing 41" 41" 41" 41" 41" 41" v A Y-Cantilever NA NA NA NA NA NA J Uplift DCR 55.8% 55.8% 55.8% 55.8% 55.8% 55.8% XSpacing 48" 48" 48" 48" 48" 48" X-Cantilever 16" 16" 16" 16" 16" 16" o Y-Spacing 74" 74" 74" 74" 74" 74" a Y-Cantilever NA NA NA NA NA NA Uplift DCR 75.6% 75.6% 75.6% 75.6% 75.6% 75.6% Layout Staggered Staggered Staggered Staggered Staggered Staggered Applied Wind Zone WZ2e,2r,3 WZ2e,2r,3 WZ2e,2r,3 WZ2e,2r,3 WZ2e,_2r,,3 -'WZ2e,2r,3 Wind Pressure -22.6 psf -22.6 psf -22.6 psf -22.6 psf -22.6 psf -22.6 psf X-Spacing 64" 64" 64" 64" 64" 64" rL X-Cantilever 24" 24" 24" 24" 24" 24" v YSpacing 41" 41" 41" 41" 41" 41" m Y-Cantilever NA NA NA NA NA NA Uplift DCR 84.0% 84.0% 84.0% 84.0% 84.0% 84.0% X-Spacing 32" 32" 32" 32" 32" 1 32" •g X-Cantilever 14" 14" 14" 14" 14" 14" o YSpacing 74" 74" 74" 74" 74" 74" a Y-Cantilever NA NA NA NA NA NA Uplift DCR 75.9% 75.9% 75.9% 75.9% 75.9% 75.9% Layout Staggered Staggered Staggered Staggered Staggered Staggered Applied Wind Zone WZ2e,2r,3 WZ2e,2r,3 WZ2e,2r,3 WZ2e,2r,3 WZ2e,2r,3 W22e,2r,3 Wind Pressure -22.6 psf -22.6 psf -22.6 psf -22.6 psf -22.6 psf -22.6 psf d XSpacing 64" 64" 64" 64" 64" 64" _ w X-Cantilever 24" 24" 24" 24" ZV 24" a YSpacing 41" 41" 41" 41" 41" 41" Y-Cantilever NA NA NA NA NA NA J Uplift DCR 84.0% 84.0% 84.0% 84.0% 84.0% 84.0% XSpacing 32" 32" 32" 32" 32" 1 32" X-Cantilever 14" 14" 14" 14" 14" 1 14" c YSpacing 74" 74" 74" 74" 74" 74" a. Y-Cantilever NA NA NA NA NA NA Uplift DCR 75.9% 75.9% 75.9% 75.9% 75.9% 75.9% Layout Staggered Staggered Staggered Staggered Staggered Staggered 1.X and Y are mapmums that are always relative to the structure framing that supports the PV. X is across framing members and Y is along framing members. 2.Where present,the green and red hatching in Applied Wind Zone rows corresponds to hatching on the Site Plan page of the plan set. Qualification Results MP Name MP4 MPS MP6 MP7 MP2 MP3 Member Member Impact Member Impact Member Impact Member Impact Member Impact Member Impact Evaluation Check OK Check OK Check OK Check OK Check OK Check OK Results