Loading...
HomeMy WebLinkAbout50573-Z o�OSUFFQI Town of Southold 6/22/2024 a y P.O.Box 1179 o _ 53095 Main Rd 4,1 - Sao Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45298 Date: 6/22/2024 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 8850 Route 25,Laurel SCTM#: 473889 Sec/Block/Lot: 122.-7-3.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/29/2024 pursuant to which Building Permit No. 50573 dated 4/22/2024 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: interior alterations to existing commercial building_(McDonalds)as applied for. The certificate is issued to Cofam Realty Co of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50573 6/5/2024 PLUMBERS CERTIFICATION DATED 0 ()ri(Tnature 4�oSUFFnt, �o TOWN OF SOUTHOLD BUILDING DEPARTMENT H x; TOWN CLERK'S OFFICE c . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50573 Date: 4/22/2024 Permission is hereby granted to: Cofam Realty Co Attn: Controller 10 Rabro Dr Hauppauge, 'NY 11788 To: Construct interior alterations to an existing commercial building to include menu board, kiosk and kitchen equipment and finishes as applied for per ICC ANSI A117.1-2009 Accessibility requirements. At premises located at: 8850 Route 25, Laurel SCTM #473889 Sec/Block/Lot# 122.-7-3.1 Pursuant to application dated 3/1/2024 and approved by the Building Inspector. To expire on 10/22/2025. Fees: COMMERCIAL ADDITION/ALTERATION $416.00 CO-COMMERCIAL $100.00 Total: $516.00 Building Inspector o��OF SO�j�ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1 1 97 1-0959 sear.devlin(c�town.southold.ny.us DUNT`I, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Cofam Realty Co Address: 8850 Rt. 25 city:Laurel st: NY zip: 11948 Building Permit#: 50573 Section: 122 Block: 7 Lot: 3.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Cain/ Borra Electric License No: 42963ME SITE DETAILS Office Use Only Residential Indoor X Basement Service Commerical X Outdoor 1st Floor X Pool New X Renovation X 2nd Floor Hot Tub Addition Surrey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 7 Ceiling Fixtures Bath Exhaust Fan Service 3 ph X Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser- Single Recpt 1 Recessed Fixtures CO Detectors Sub Panel 200A A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 2'x2'LED F2 Exit Fixtures Sump Pump Other Equipment: Plugmold.Outlet 3' (6) , 3Phase 200A Panel 42 Circuits / 7 Used w/200A Breaker,in M.D.P. Labeled AP3 w/ (3)220GF1 Braekers & (1)120GF1 Breaker Notes: New Panel & Counter Area Inspector Signature: Date: June 5, 2024 S.Devlin-Cert Electrical Compliance Form OF SOUIyo� * # TOWN OF SOUTHOLD BUILDING DEPT. 'gum, 631-765-1802 �0> 4� INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ rFRAMING NDATION 2ND [ ] INSULATION/CAULKING[ /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: (w DATE INSPECTOR SOUI 1-3 �v � # TOWN OF SOUTHOLD BUILDING-DEPT. o�y NI , 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. . [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE'SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION '[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: A4 e `J DATE INSPECTOR OF SOGTy�� f # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ OUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION DRE C/O [ ] RENTAL REMARKS: o AK:,�7k� 'A 641 DATE INSPECTOR OF SOUIyOIo # # TOWN OF SOUTHOLD BUILDING DEPT. courm 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING FINAL Corn 44 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: l v-f La&: 6?�A&MAA � (b V4Ar4 , - Rr O-WL1,364 n� I��V1 VU44c �w( D C DATE INSPECTOR CORE STATES GROUP June 10, 2024 Town of Southold Building Department 54375 NY-25 Southold, NY 11971 Re: McDonald's Restaurant 031-1745 Mattituck, NY To Whom it May Concern: The following project is an existing building with an existing draft curtain separating the dining ceiling area from the kitchen ceiling area. A portion of the draft curtain is equipped with sprinklers below the ceiling to provide a deluge curtain to complete the separation between the kitchen ceiling and the dining room ceiling. E A ARC y�T Sincerely, N t`� Jennifer Hauser Project Architect °� '� OF N Core States Group • • 4 224.585.3955 1 ihauser@core-states.com E E U E i JUN 2 1 2024 Buildir�.1 Dep.rtrnent TOVIIi7 of'sol .101d r "t. Page 1 FIELD INSPECTION REPORT DATE COMMENTS d FOUNDATION (1ST) y ------------------------------------ �C rA FOUNDATION (2ND) z i/ A✓ cam° o e- C'3� 111 Gy ROUGH FRAMING& PLUMBING t 1 ` ..� v r r INSULATION PER N.Y. y STATE ENERGY CODE /On ..� FINAL ADDITIONAL COMMENTS cA m 9 a k H O z zt� � y x d ' Wo b H SUE Fi,r� TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. 0.Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax(631) 765-9502 https://www.southoldtownnygov Date Received APPLICATION FOR BUILDING PERMIT ' For Office Use Only PERMIT NO. 5 05r/7 3 Building Inspector: Applicafions'and forms must,be filled out in their entirety:Incomplete applications will not be accepted. Where the Applicant is not the owner,an �'�� �- Owner's Authorization form.(Page 2)shall,be completed.,. ' '° Date:2/23/24 OWNER(S)OF PROPERTY: Name:CoFam•.Realty,.Co F, #s000-122.00-07.00-003.001 scrM „w Project Address:8850 Main-Rd Mattituck NY Phone#:(212) 829-9090,.ext_1 Email:richard@cohencohenllp.com Mailing Address:122 East 42nd Street, 4th.Floor New York, ,New York 10168. . CONTACT PERSON: Name:George.Kavrakis Mailing Address:g Wedge wood Lane Phone#:516,298 2355 Email:GeorgeK@BlackacreCorp.com DESIGN PROFESSIONAL INFORMATION: Name: .. . . . . ore States ,Group,- r .... user....._ .._ . ....... .._. ... _ . ._. ...._. Mailing Address:135 Water St,-Naperville, IL Phone#: Email:JHauser@Core-states.com CONTRACTOR INFORMATION: Name:DDI Contracting .. Mailing Address:830 E Bay Dr,,West Islip,, NY 11795 Phone#:631-827-4720 Email:mike@ddicontracting.com ,DESCRIPTION OF PROPOSED CONSTRUCTION . ❑New Structure DAddition @Alteration []Repair ❑Demolition Estimated Cost of Project: 2 Other Minor Interior Alteration @ Front Counter. $82.000 Will the lot be re-graded? E]Yes @No Will excess fill be removed from premises? DYes @No ,. 1 I PROPERTY'INFORMATION Existing use of property:A-2 Re.staUrant Intended use ofproperty:A-2 Restaurant Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to I this property? OYes BNo IF YES, PROVIDE A COPY. B Cheek,Box AfteriReading: The owner/contractiir/design professfonalls responsible,for all drainage and storm water issues as.provided by ;:Chapter 23G of:the•Town,Code..APPLICATION IS HEREBY MADE to the Building De0.artment'for the Issuance of a'Building Permit pursuant to the Building Zone ' Ordinance of the Town.of Southold,'Suffolk,County,New York and othor,applicable laws;Ordinarices,or Regulations,for the construction of buildings, additions,alterations-or for removal or demolition as'hereln,described.The applicant agrees to comply,with all applicable•laws,ordinances,building code, ',housing code.and regulations and•t0 admit authorized inspectors-on premises and1n'building(s)for necessary;lnspections.False statements made herein are punishable as a Class,A misdemeanor;pursuant to Section Z10AS of the New York State Penal Law, Application Submitted B George Kavrakis RAuthorized Agent DOwner pp y(print e . g Signature of Applicant: Date: '2/23/24 STATE OF NEW YORK) SS: COUNTY OF S YL— ) eo�G �0.�j CC,}t`k\S being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named,. (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized'to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ? _day of' P h No ry Public • :' JETJNIFERARNC _D Notary Public,State of lewYork PROPERTY OWNER AUTHORIZATION :, f: No.0IAR63131 6 !;: %y (qualified in Nassau i ounty (Where the applicant is not the owner ,j , !'ommission Expiras Octobe-14,20,vio I, Y��}'vticl �r!•^. -� q''�V'�` �isid'n a 1 ' . ',� `Jr?1LC�[� �'aC do hereby authorize Q G ( to apply on my behalf to the Town of Southold Building Department for approval as described herein. 2/23/24. Owner's Signature Date Richard Cohen Print Owner's Name 2. i Building Dmartment Annlication AUTHORIZATION (Where the Applicant is not the Owner) 1, Richard Cohen, of Cofam Realty Cc residing at (Print property owner's name) (Mailing Address). ' 1 do hereby authorize. George Kavrakis (Agent) to apply on my behalf to tlie� Southold Building Department. , specifically and only for the,building application at' 8850 Main Rd, Mattituck NY. McDonald's. Scope: Minor Interior Alteration at Front Counter. 2/23/24 (Owner's Signature) (Date) Richard Cohen (Print Owner's Name). ra X3 `to D 3 2024 �guFFOL,�c BUILDING DEPARTMENT- Electri I spector TOWN OF SOUTHOLD guiidingDoPar oeot o - Town Hall Annex- 54375 Main Road - P0.�6i4 o Southold, New York 11971-0959 yjj0� �ap�� Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh(cD-southoldtownny.gov - seand(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: =-20 Company Name: J,®r rq i rC Electrician's Name: License No.: Pft&g q(®-- Elec. email: Qtfk berr6k• CO AA Elec. Phone No: 31 , 218 25�I request an email copy of Certificate of Compliance Elec. Address.: G) (,). &ACkofete wC.mif e, �'�� ((?C)f JOB SITE INFORMATION (All Information Required) Name: G-6VVX P- Co N1epo o As Address: Ra5b Pov Cross Street: d Phone No.: -b2.,7 Bldg.Permit#: IS-®S]'� email: yKv V-e ,D-C>i CA'AreL&i ,c�0 Tax Map District: 1000 Section: 122 .--1 Block: Lot: BRIEF DESCRIPTIQN OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): SRvr xcp- orb Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ® NO Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES R NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION �L CO- i�� PERMIT# Address: Switches CL Outlets U GFI's Surface � r Sconces V� 1 H H's �i�,A1011 4 UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV Inst Hot DeHum Transfer HOT TUB/SPA Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps2� Have Used f Comments G a Lim MAY 2 3 2024 BUILDING DEPARTMENT- Electri I spector 0 .,Partment e�'s TOWN OF SOUTHOLD 5 �d'e�sJ old m =` ! Town Hall Annex - 54375 Main Road - PO Be* o Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 jameshasoutholdtownny.gov - seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: ' c .a Company Name: <foAi✓e '3c., r-C, nc Electrician's Name: � ' ;�- License No.: �� �, EIec. email: ';) vt crecl. C �10 Elec. Phone No:SIC-, 2.31 2.18 !E�I request an email copy of Certificate of Compliance Elec. Address.: C) L4,1. JVX `�I e �Sj . JOB SITE INFORMATION (All Information Required) Name: �.. ,� koe,-?A ( $firms . a5' Address: Cross Street: - r Phone No.. Bldg.Permit #:�O '�.j email: t �ie fJ DoI C,•.v c-C,,A Tax Map District: 1000 Section: �`2� . -"� Block: Lot: BRIEF DESCRIPTITN OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ® NO Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ® NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[—]Fire Reconnect❑Flood Reconnect[-]service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT.DUE WITH APPLICATION � i � NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) o a A A A A A 474254521 PF NORTHEAST BROKERAGE INC 1035 ROUTE 82 Q HOPEWELL JUNCTION NY 12533 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER DDI GENERAL CONTRACTING LLC COUNTY OF SUFFOLK 830 EAST BAY DRIVE 355 YAPHANK AVENUE WEST ISLIP NY 11795 YAPHANK NY 11980 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12367 807-1 743217 11/13/2023 TO 11/13/2024 2/23/2024 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2367 807-1, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/MIWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY AFFORDS COVERAGE TO THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. MICHAEL NOVELLANO A TWO PERSON LLC THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE-PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SUR NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 801495861 U-26.3 YOH, workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed Insurance agent of that carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured DDI GENERAL CONTRACTING LLC 631-252-1148 830 E BAY DRIVE WEST ISLIP,NY 11795 1 c.Federal Employer Identification Number of Insured Work Location of Insured(Only required If coverage is specifically limited to or Social Security Number certain locations in New York State,I e.,Wrap-Up Policy) 474254521 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company County of Suffolk 3b.Policy Number of Entity Listed in Box"1a" 355 Yaphank Avenue DBL690252 Yaphank, NY 11980 3c.Policy effective period 04/13/2023 to 04/12/2025 4. Policy provides the following benefits: ® A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. (� B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 2/23/2024 By AW 4t (Signature of Insurance carrier's authorized representative or NYS Licensed Insurance Agent of that Insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4B,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those Insurance carriers are authorized to issue Form DS-120.1.Insurance brokers are NOT authorized to Issue this form. 1313-120.1 (12-21) 11111 iiiiiii (iiiiiiuiiiiJill A ORV CERTIFICATE OF LIABILITY INSURANCE DAT 2123/2DIYYYY) 0 /23/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND ORALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer'rights to the certificate holder In lieu of such andonsement(s). NT CT PRODUCER NAME: Christine Muniz PF Northeast Brokerage Inc PHONE E 1845)22MI07 ac No: (845)227-8816. 1035 Route 82 ADDRESS: cmuniz@pfnortheast.com INSURER(S)AFFORDING COVERAGE NAIC 0 Hopewell Junction NY 12533 INSURER A: Continental Insurance Co 36289 INSURED INSURERS: DDI General Contracting LLC INSURERC: 830 E Bay Drive INSURERD: INSURER E: West Islip NY 11795 INSURER F: COVERAGES CERTIFICATE NUMBER: CL2411515434 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, rAUDL15UHN POLICY EFF Po A TYPE OF INSURANCE I POLICYNUMBER MMIDD/YYW MMIDDIWYY LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE ❑X OCCUR PRE SES Ea occurre ee $ 100,000 X Contractual Liability MED EXP Any one erson $ 15,000 7036423400 01/30/2024 01/30/2025 PERSONALS,ADV INJURY $ 2,000,000 GEN'LAGGREGATE LIMITAPPLIES PER: GENERALAGGREGATE S 4,000,000 POLICY jECT LOC PRODUCTS-COMP/OPAGG $ 4,000,000 OTHER: $ AUTOMOBILE LIABILITY OMB NED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per aeoident) S AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident X UMBRELLA LIAS M OCCUR EACH OCCURRENCE $ 3,000,000 A EXCESS LIAR CLAIMS-MADE 7036423395 01/30/2024 01/30/2025 AGGREGATE' $ 3,000,000 DED X RETENTION$ 10,000 $ WORKERS COMPENSATION AND EMPLOYERS'LIABILITY YIN STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Provided it is required by written contract,the following are named as additional insured as respects general liability with regard to the Insured's ongoing operations under form CNA76079XX(10-16),to the extent provided therein:County of Suffolk CERTIFICATE HOLDER. CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN County of Suffolk ACCORDANCE WITH THE POLICY PROVISIONS. 355 Yaphank Avenue AUTHORIZED REPRESENTATIVE Yaphank NY 11980 Coftn ©1988-2016 ACORD CORPORATION. All rights reserved. ACORD 26(2016103) The ACORD name and logo are registered marks of ACORD iSuffolk County Dept.of Labor,Licensing$Consumer Affairs HOME IMPROVEMENT LICENSE Name LAUREN C NOVELLANO Business Name DDI General Contracting LLC This certifies that the bearer is duly licensed License Number HI-68459 by the County of sutfolk Issued: 11/01/2023 jam.C4,,{,� Expires: 11/01/2025 Commissioner Ana This license is the property of Suffolk County Department of Labor,Licensing&Consumer Affairs. Possession of this license does not guarantee its validity. Additional Business Name License Category H50-Renovations KIOSK GUIDELINES GENERAL NOTES CONSTRUCTION DOCUMENTS: TEMPORARY FACILITIES. UTILITIES & CONTROLS• GENERAL REQUIREMENTS 1. BY EXECUTION OF THE CONSTRUCTION CONTRACT, THE CONTRACTOR REPRESENTS 1. PROVIDE BARRIERS, FENCES AND OTHER CONTROLS TO PREVENT PUBLIC I ENTRY TO THAT HE OR SHE HAS (1) READ AND UNDERSTANDS THE REQUIREMENTS OF THE CONSTRUCTION AREAS, AND TO PROTECT CONSTRUCTION WORKERS AND THE PUBLIC CONSTRUCTION DOCUMENTS, (2) VISITED THE PROJECT-SITE, (3) BECOME FAMILIAR FROM HAZARDS OF CONSTRUCTION. SINGLE SIDED KIOSK OTHER KIOSK PLACEMENT WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED, (4) 2 PROVIDE PROTECTION OF CONSTRUCTION MATERIALS FROM LOSS, DAMAGE, FIRE OR CORRELATED PERSONAL OBSERVATIONS WITH REQUIREMENTS OF THE CONTRACT CONFIGURATION: PARALLEL KIOSK CAN BE ANGLED AND/OR FREE FLOATING DOCUMENTS, AND (5) THAT HE OR SHE WILL COMPLY WITH ALL REQUIREMENTS OF THEFT, AND PROTECT EXISTING CONSTRUCTION FROM DAMAGE BY CONSTRUCTION GENERAL NOTES: THE CONSTRUCTION DOCUMENTS. OPERATIONS. Z -TYPICAL KIOSK QUANTITY (4), FINAL QUANTITY PER RESTAURANT TO BE 3. PROVIDE TEMPORARY FIRE-PREVENTION MEASURES AND PROCEDURES INCLUDING 0 2. THE INTENT OF THE CONSTRUCTION DOCUMENTS IS TO INCLUDE ALL ITEMS DETERMINED BY MCDONALD'S OPERATIONS TEAM AND ACM NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE CONSTRUCTION FIRE-EXTINGUISHERS PER AHJ REQUIREMENTS. a -12'CLEAR DIMENSION HIGHLY RECOMMENDED BETWEEN FRONT WORK - AND TO PROVIDE (FURNISH AND INSTALL) ALL PRODUCTS, MATERIALS, COUNTER AND KIOSK *EXISTING CONDITIONS TO BE CCNSIDERED EQUIPMENT OR ACCESSORIES REQUIRED FOR PROPER OPERATION, IN ACCORDANCE 4. PROVIDE DUMPSTERS AND COLLECT WASTE DAILY. DISPOSE OF MATERIAL IN A cn LAWFUL MANNER. PLACE DUMPSTER IN LOCATION APPROVED BY OWNER OR w -SEE PUCK HOLDER GUIDELINE FOR PLACEMENT WITH THEIR MANUFACTURER'S REQUIREMENTS. LANDLORD, AS APPLICABLE. Tr WIN. 3. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY - WHAT IS REQUIRED BY ONE GENERAL PRODUCT REQUIREMENTS:Trlr -WALL FINISH BEHIND KIOSK TO COORDINATE WITH DECOR SHALL BE AS BINDING AS IF REQUIRED BY ALL. WHILE PREPARED WITH DUE CARE - AND DILIGENCE, PERFECTION IS NOT POSSIBLE. DESIGN AND CONSTRUCTION ARE 1. STORE PRODUCTS PER MANUFACTURER'S INSTRUCTIONS, PROTECTED FROM DAMAGE 0 0 0 0 -POWER FROM ABOVE (WITH STANDARD CEILING HEIGHT) IF CEILING IS COMPLEX - EVERY POSSIBLE CONDITION OR CONTINGENCY CANNOT BE ANTICIPATED STORE ABUSE AND WITH VENTILATION T AVOID CONDENSATION. s2•a4a•CLEAR GREATER THAN 10'-6" CONTACT USRD PROJECT MANAGER, SEE KIOSK OR FULLY INDICATED WITHIN THE DOCUMENTS. ' SPADE IN FRONT CUT SHEET FOR ADDITIONAL ELECTRICAL INFORMATION OF KIOSK FACE 2. APPLICATION OF A MATERIAL OR EQUIPMENT ITEM TO WORK INSTALLED BY OTHERS 4. CAREFULLY STUDY AND COMPARE THE VARIOUS DRAWINGS (INCLUDING BUT NOT -CONSIDER SIZE OF BASE PLATE FOR CLEARANCE WHEN ANGLING A KIOSK LIMITED TO ARCHITECTURAL, STRUCTURAL, MECHANICAL OR ELECTRICAL) AND OTHER CONSTITUTES ACCEPTANCE OF THAT WORK AND ASSUMPTION OF RESPONSIBILITY FOR w AGAINST A WALL/PARTITION CONTRACT DOCUMENTS WITH THE EXISTING CONDITIONS AT THE PROJECT-SITE SATISFACTORY INSTALLATION AND PERFORMANCE. I Q ® BEFORE STARTING CONSTRUCTION. REPORT ERRORS INCONSISTENCIES OR OMISSIONS E2 -KIOSK MAY BE TURNED ON AN ANGLE TO INCREASE SCREEN VISIBILITY DISCOVERED FOR CLARIFICATION. THE CONTRACTOR WILL BE RESPONSIBLE FOR 3. INSPECT EACH ITEM OF MATERIAL OR EQUIPMENT IMMEDIATELY PRIOR TO 2'-4- -DOUBLE SIDED OR SINGLE SIDED KIOSKS CAN BE FREE FLOATING OR REPAIR OR CORRECTION COSTS IF WORK IS EXECUTED WITH KNOWLEDGE THAT IT INSTALLATION. REJECT DAMAGED AND DEFECTIVE ITEMS. 3-MIN-0 2'-4- INVOLVES AN ERROR, INCONSISTENCY OR OMISSION - WITHOUT THE ABOVE NOTICE. 4. COORDINATION WITH FIXTURES, FURNISHINGS & EQUIPMENT (FF&E): I a-o• 5. REVIEW THE OWNERS SEPARATE CASEWORK/FIXTURES FURNISHINGS EQUIPMENT & FRONT ELEVATION -WHEN SPACE ALLOWS, THIS SOLUTION IS THE ULTIMATE IN INTERRUPTING 5. IN THE EVENT OF CONFLICT OR AMBIGUITY WITHIN THE CONSTRUCTION DOCUMENTS, � � � ARCHITECT OF RECORD: CUSTOMERS AND IDEAL WHEN LARGE GROUPS ARE EXPECTED TO ORDER THE CONTRACTOR WILL BE DEEMED TO HAVE AGREED TO PROVIDE THE GREATER SIGNAGE DRAWINGS FOR UNIT SIZES, WEIGHTS, SERVICE-CONNECTIONS AND TOGETHER CLEARANCES REQUIRED - WHETHER FURNISHED OR INSTALLED BY THE CONTRACTOR w SIDE: ELEVATION FRONT ELEVATION PLAN VIEW QUANTITY AND / OR BETTER QUALITY OF MATERIALS AND / OR WORK. OMISSIONS IN �i 3•-0- OR OTHERS. VERIFY THAT REQUIRED ROUGH-INS, CONNECTIONS AND CLEARANCES MIN THE DESCRIPTION OF THE WORK DO NOT RELIEVE THE CONTRACTOR FROM WILL BE PROVIDED. PROVIDE OPENINGS AND DELIVERY ACCESS FOR FF&E ITEMS, ;� :..- .p��\ -ENSURE ADEQUATE CIRCULATION AROUND FREE FLOATIIJG KIOSKS PROVIDING A COMPLETE PROJECT. j AND PROVIDE STAGING SPACE FOR THEIR INSTALLATION. REPORT DISCREPANCIES OR GENERAL NOTES: 0 0 0 0 -IDEAL WHEN A LARGE QUANTITY OF KIOSK FACES ARE REQUIRED GENERAL SCOPE OF WORK: OMISSIONS OF EQUIPMENT REQUIREMENTS PRIOR TO INSTALLATION. -TYPICAL KIOSK QUANTITY (4), FINAL QUANTITY PER RESTAURANT TO BE 32•■4IN FREAK OFF MMFACE 1. PERFORM ALL CONSTRUCTION WORK INDICATED OR OTHERWISE REQUIRED FOR 6. PROVIDE ALL HVAC, PLUMBING, GAS OR ELECTRIC SERVICE CONNECTIONS TO sf �a41 17 � DETERMINED BY MCDONALD'S OPERATIONS TEAM AND ACM COMPLETION OF THE PROJECT - EXCEPT AS NOTED OTHERWISE. CASEWORK / FIXTURES, SIGNAGE, OR EQUIPMENT INDICATED (WHETHER UNITS ARE -12'CLEAR' DIMENSION HIGHLY RECOMMENDED BETWEEN FRONT I / INSTALLED BY CONTRACTOR OR BY OTHERS). * / P 2. SCHEDULE AND COORDINATE THE WORK OF THE COMPLETE PROJECT TO ASSURE AN IT IS A VIOLATION OF THE COUNTER AND KIOSK EXISTING CONDITIONS TO BE CONSIDERED / EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION OF ALL ELEMENTS - WITH GENERAL EXECUTION OF THE WORK: LAW FOR ANY PERSON, J(` / UNLESS ACTING UNDER THE -SEE PUCK HOLDER GUIDELINE FOR PLACEMENT PROVISIONS FOR ACCOMMODATING ITEMS TO BE INSTALLED LATER. 1. ESTABLISH AND MAINTAIN DURABLE MARKERS TO LOCATE ALL ELEMENTS OF THE DIRECTION OF A LICENSED ARCHITECT, TO ALTER AN ITEM WORK, INCLUDING BUT NOT LIMITED TO PARTITIONS, CASEWORK, FIXTURES,-WALL FINISH BEHIND KIOSK TO COORDINATE WITH DECOR PLAN-a- 3. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, EQUIPMENT AND LIGHT-FIXTURES, AND THEIR RELATED MECHANICAL, ELECTRICAL AND IN ANY WAY. TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS PLUMBING CONNECTIONS. -POWER FROM ABOVE (WITH STANDARD CEILING HEIGHT) IF CEILING IS OF THE WORK. CL. 6. \ = � GREATER THAN 10'-6" CONTACT USRD PROJECT MANAGER, SEE KIOSK 4. PROVIDE ALL REQUIRED NOTICES FOR INSPECTIONS AND APPROVALS OF THE WORK 2. AT PROJECTIONS OF FINISHED SURFACES, INCLUDING PILASTERS OR THICKENED .� ® w CUT SHEE=T FOR ADDITIONAL ELECTRICAL INFORMATION WALLS, RETURN ALL EXPOSED SURFACE FINISHES BACK TO THE PRIMARY SURFACE - .P � -CUSTOMER QUEUES MAY FORM AND CREATE CONGESTION WITH BY THE AUTHORITY HAVING JURISDICTION (AHJ). THE MOST RESTRICTIVE CODE EVEN IF NOT SPECIFICALLY NOTED. OTHER ORDER POINTS. USE THIS CONFIGURATION ONLY WHEN THERE IS REQUIREMENTS AS INTERPRETED BY LOCAL OFFICIALS WILL APPLY. W n a' PERFORM ALL CUTTING, PATCHING AND FITTING TO ACCOMMODATE CONSTRUCTION SUFFICIENT CLEAR SPACE IN FRONT OF KIOSK 5. VERIFY LOCATIONS OF EXISTING UTILITY SERVICE CONNECTIONS SERVING THE 3. -WALL OR PARTITION NOT NECESSARILY REQUIRED BEHIND KIOSK, SINGLE WORK AND TO ACHIEVE THE INTENT OF THE CONSTRUCTION DOCUMENTS. CUT & � PROJECT BEFORE STARTING CONSTRUCTION. LOCATIONS OF EXISTING UTILITIES NOTED PATCH PARTITIONS FOR INSTALLATION OF PLUMBING OR ELECTRICAL SERVICES AND ARE APPROXIMATE, AND MAY BE BASED ON UN-VERIFIED INFORMATION. PROVIDE ALL SIDED CONFIGURATION ACTS AS A PARTITION CONNECTIONS REQUIRED AT UTILITY CONNECTION POINTS AT NO ADDITIONAL COST TO FOR INSTALLATION OF WALL BLOCKING, IF NECESSARY. PROVIDE ESCUTCHEONS, -SINGLE SIDED KIOSKS MAY BE ANGLED SLIGHTLY (10'-15•) TO THE OWNER. GROMMETS AND SIMILAR SURFACE CLOSURE OR FINISHED TRIMS AT EXPOSED PROVIDE BETTER SCREEN VISIBILITY PENETRATIONS OF FINISHED SURFACES. -WORK WELL SIDE BY SIDE WITH A 5'WIDE PARTITION/WALL BEHIND PUCK DISPENSER 6 TOOVIDE E SURE COORDINATION BETWEEN CTORS ETH A FULL-SET OF THE ALL TRADES AND EACHTSUBCEON ONTRAOCTORENTS 4. BRACE PARTITIONS, SUSPEND CEILINGS OR SOFFITS, AND BRACE PLATFORMS, m o SUSPENDED ITEMS OR SIMILAR CONSTRUCTION ONLY TO STRUCTURAL ELEMENTS oou LOCATION GUIDELINES ABOVE - EVEN IF NOT SPECIFICALLY NOTED. DO NOT ANCHOR TO ROOF DECK P 7. ALL CONSTRUCTION WORK MUST BE OF GOOD QUALITY - FREE FROM DEFECTS AND a s N o PLUMBING / SPRINKLER PIPES, DUCTWORK, ELECTRICAL CONDUIT OR SIMILAR W o" GENERAL NOTES IN ACCORDANCE WITH REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS - OR THE ELEMENTS. ,0 o 0 -FLUSH MOUNT PUCK DISPENSER PER KIOSK FACE WORK MAY BE CONSIDERED DEFECTIVE - AND SUBJECT TO CORRECTION OR a - Q N N P -BOTTOM OF SINGLE PUCK DISPENSER SHOULD NEVER BE LOWER THAN 27" AFF REPLACEMENT BY THE CONTRACTOR WITHIN A PERIOD OF ONE (1) YEAR AFTER COORDINATION WITH ADJACENT CONSTRUCTION SUBSTANTIAL COMPLETION. o o -TOP OF PUCK DISPENSER NEVER HIGHER THAN 48" AFF 1. LIW11T WORK TO OCCUR WITHIN THE PROJECT SITE, OR WITHIN OTHER AREAS o o�� °�- INSTALLATION OF OWNER-FURNISHED PRODUCTS: DESIGNATED OR APPROVED FOR USE BY THE OWNER / LANDLORD / OR V n o PUCK LOCATION 'A' DEVELOPER. CONNECT TO EXISTING UTILITY SERVICES BEYONDI THE PROJECT-SITE IN C o ° o DOUBLE SIDED KIOSK -HME FLUSH MOUNT PUCK DISPENSER 1. COORDINATE, RECEIVE AT SITE, VERIFY RECEIPT, HANDLE, STORE ON-SITE (IF ...I a,, ° -KIOSK PARALLEL TO WALL REQUIRED), PROTECT AND INSTALL OWNER-FURNISHED PRODUCTS, AND PROVIDE THE MOST EXPEDITIOUS MANNER POSSIBLE WITH MINIMAL DISTURBANCE OF EXISTING � o �, CL c CONFIGURATION: PERPENDICULAR TO WALL/PARTITION MULTIPLE UNITS -PUCK DISPENSER TO BE MOUNTED ON THE WALL OR SERVICE CONNECTIONS AS APPLICABLE. ELEMENTS OR FINISHES. _ ° ° ° E,o� PARTITION BEHIND THE KIOSK o ° °i3 � m -PUCK LOCATOR TO ALWAYS BE MOUNTED 4" TO THE 2. RESTORE ALL AREAS OF EXISTING LANDSCAPING (INCLUDING SPRINKLER SYSTEMS) c°i c'- o aE'u RIGHT OF THE KIOSK IF SPACE ALLOWS 2. NOTIFY THE OWNER WITHIN FIVE (5) DAYS OF RECEIPT OF ANY ITEMS ARE MISSING, DISTURBED DURING CONSTRUCTION TO ITS ORIGINAL CONDITION. 0 d °' t r *DISPENSER MAY BE MOUNTED EITHER DIRECTLY TO DAMAGED OR OTHERWISE DEFECTIVE. LACK OF NOTIFICATION WILL BE CONSIDERED M .a ;"-o KIOSK OR TO WALL BEHIND KIOSK PRESUMPTIVE PROOF THAT ALL ITEMS DID ARRIVE UNDAMAGED AND IN PROPER FINAL CLEANING: C3 `o c�3» ° a`, a QUANTITIES, AND ANY REPLACEMENT OR REPAIRS NECESSARY WILL THEN BE THE p = u ° c r RESPONSIBILITY OF THE CONTRACTOR. 1. JUST BEFORE OWNER OCCUPANCY, CLEAN ALL SURFACES INCLUDING FIXTURES AND N s a° ° ° ° c o ° 3. REPAIR DAMAGE TO OWNER-FURNISHED PRODUCTS CAUSED BY CONSTRUCTION EQUIPMENT FOR THE OWNER'S USE AND OPERATION. POLISH GLASS AND PLUMBING v co N 49 E- c FIXTURES TO BE WITHOUT NOTICEABLE STREAKS. VACUUM CLEAN FLOORS AND DAMP ° `° " o ° °' ° OPERATIONS TO THE OWNER'S SATISFACTION. WIPE WALLS, FIXTURES AND EQUIPMENT TO BE DUST-FREE WITHOUT STAINS, FILMS � o U F � 6 ` 2 PLAN VIEW AND OTHER DISTRACTING SUBSTANCES. o o ° 2. CLEAN THE PROJECT SITE OF RUBBISH, LITTER AND OTHER FOREIGN SUBSTANCES. 0 a �� FRONT ELEVATION FRONT ELEVATION BROOM CLEAN PAVED AREAS AND REMOVE STAINS, SPILLS AND OTHER FOREIGN N N o,_� m O U DEPOSITS. RAKE GROUNDS THAT ARE NEITHER PAVED NOR PLANTED, TO A SMOOTH Q v o t ° °0 `EVEN-TEXTURED SURFACE. o ° °o. rn-. o0 ° �,� o O`0 PUCK LOCATION B a -HME FLUSH MOUNT PUCK DISPENSER d c -KIOSK PERPENDICULAR TO WALL o 17. iN' -PUCK DISPENSER TO BE MOUNTED DIRECTLY TO 0 3 w.� c o.n o o E w o U �- � ° Ill c a a03 KIOSK, BACK TO BACK N 0� m N u u -DISPENSERS SHOULD ALWAYS BE MOUNTED ON KIOSK SIDE ELEVATION FRONT ELEVATION SIDE CLOSEST TO THE WALL n 3.o °c IL n I- - 'j - 7 F in a m 0O m W DO Li U � o 0 ° b I o z = UJ N o ? O� M N o o I - QY NJ ,>�>jQ wr n- o l 4•-0• r-0• J2•x49•CLEAR y Z � Q 6 SPACE IN FRONT U OF KIOSK FACE 4'-0' � PLAN VIEW FljDORPLAN VIEW CANNOT OVERLAP GENERAL NOTES: N -TYPICAL KIOSK QUANTITY (4). FINAL QUANTITY PER RESTAURANT TO BE FRONT ELEVATION DETERMINED BY MCDONALD'S OPERATIONS TEAM AND ACM z ! -12'CLEAR DIMENSION HIGHLY RECOMMENDED BETWEEN FRONT COUNTER AND KIOSK *EXISTING CONDITIONS TO BE CONSIDERED -SEE PUCK HOLDER GUIDELINE FOR PLACEMENT -WALL FINISH BEHIND KICSK TO COORDINATE WITH DECOR > a z � -POWER FROM ABOVE (WITH STANDARD CEILING HEIGHT) IF CEILING Q IS GREATER THAN 10'-6" CONTACT USRD PROJECT MANAGER, SEE KIOSK (� a z N CUT SHEET FOR ADDITIONAL ELECTRICAL INFORMATION z -IDEAL WHEN PLACED IN FRONT OF THE SERVICE AREA, LESS LIKELY TO 0 w 0 a a ? a W INTERFERE WITH FRONT COUNTER QUEUING li m w a -IDEAL WHEN TRYING TO CAPTURE CUSTOMERS FROM TWO ENTRANCES p �, Q 0 N w -LEVERAGES EXISTING DECOR ELEMENTS TYPICALLY SEEN IN OUR STANDARD _ z ,n Lj u DECOR LAYOUTS w Of o -THIS IS THE PREFERRED PLACEMENT CONFIGURATION 'J O XN �_ ( 0 Li r uvi o X - I N LkJ o U �`' N o L0 G IN 190 a: V) GENERAL NOTES ACCESSIBLE AND USABLE BUILDINGS 8c FACILITIES ICC ANSI A117 . 1 I r _ _ _ T- I __1 I I l z F - - - - - - - -I - I I a 60' MIN I I I I I I I r - - I I I a z 12" MIN MIN I I I z I 12k 2r c MIN; I I 24* MIN o - o 36" 42" � - - �' 10 \ z I I o - - MIN - - MIN MIN Ld I I I JZ to Ll p "F BOTH CLOSER k LATCH ARE PRODDED OPTION 1 OPTION 2 "48'-IF MINIFIF BOTH CLOSER k LAT CLOSER LATCH CH ARE P WIDED 'W MIN IF CLOSER IS PROVIDED Of (` I v I _ / N (a) (b) (C) (d) (e) (f) U L _ _ - J FRONT APPROACH, PULL SIDE FRONT APPROACH, PUSH SIDE HINGE APPROACH, PULL SIDE HINGE APPROACH, PULL SIDE HINGE APPROACH, PUSH SIDE LATCH APPROACH, PULL SIDE W 0 , I I I 60" MIN DIA. 36" MIN _ _ _ _ _ 42" MIN Ix < 48" 42" MIN 6 36' MIN I,x < 48'L 36" MIN L 12" MIN 12" MIN (a) (b) CIRCULAR T-SHAPED I I I I r , I � I m I I °D � I I o0 96" MIN 60" MIN 132' MIN 24" N I I ? 6 I I n I i n CLEAR WIDTH403.5.1 AT 180' TURN SIZE OFIG. 304.3TURNING SPACE (a) CAR (b) VAN MIN I I I z I x 12" x I I I • I I MIN I 04 FIGURE 502.2 ' v I I a o I VEHICLE PARKING SPACE SIZE I I 'O - - - - - n r - - - - - - 18" x LLJ 20 TURNING SPACE 12 ACCESSIBLE PARKING MI" I AO. 1 NOT TO SCALE AO. 1 NOT TO SCALE (a) (b) (a) (b) (C) MB•IF CLOSER IS PRODDED FRONT APPROACH SIDE APPROACH PULL SIDE PUSH SIDE PUSH SIDE 24" MAX 48" MIN 24" MAX , (9) FIG. 404.2.3.4 FIG. 404.2.3.5 ARCHITECT OF RECORD: LATCH APPROACH, PUSH SIDE MANEUVERING CLEARANCE AT DOORWAYS WITHOUT DOORS _ ' r "' r 4"-6 1/4" % MANEUVERING CLEARANCE AT RECESSED DOORS (a� 1� LiA Fj9 c� C� 1 1/2" MIN 1 1/4"-2" PERIMETER / 2 1/4' MAX ��• I 4 I - I g DOOR CLEARANCES f � 71 M M ) C-4 to A0. 1 NOT TO SCALE ':' Y' 3 48" MIN (a) (b) (C) °ji.. . t r" "' / / NONCIRCULAR fO FIG. 403.5 FIG. 305.3 V CLEAR WIDTH OF AN ACCESSIBLE ROUTE CLEAR FLOOR SPACE FIG. 505.5 FIG. 505.7 d`P 044177 HANDRAIL CLEARANCE HANDRAIL CROSS SECTION / KJOF N[ �U N r FIG. 305.3 CLEAR FLOOR SPACE, ' IT IS A VIOLATION OF THE FORWARD APPROACH ® URINAL 3 i LAW FOR ANY PERSON, UNLESS ACTING UNDER THE 10 HANDRAIL CLEARANCE 4" MAX VERTICCAL� CLEARANCE 0 ' DIRECTION OF A LICENSED I - 307.4 I % - r o - r ARCHITECT, TO ALTER AN ITEM A0. 1 NOT TO SCALE 1 1/2" MIN 13 1/2" MIN ! - IN ANY WAY. 204 48' MIN I r / \ z 30" MIN z >V-0" (a) FIGURE 305.5 (b) I a ua ca Q POSITION OF CLEAR z m il tO r `r a FLOOR SPACE 9 z _ - _ _ J 60" IN 60" MIN 60" MIN w / n to oo N 13 1 2" MIN 22 _ r o N !d •O V n 3 ;� • co >12" (a) WALL HUNG TYPE 3 to n v r I o n a n n FIG. 609.3 FIG. 605.2 FIG. 605.3 0 0 C144" MAX 4' MAX • o N N HEIGHT OF URINALS CLEAR FLOOR SPACE n SPACING OF GRAB BARS r„ FIG. 305.7 L- - - - - - - (a) FIG. 505.4 (b) (a) (b) (a) (b) (C 36" MI IV MANUEVERING CLEARANCE 60" MIN STAIRS HANDRAIL HEIGHT RAMPS FIG. 307.2 FIG. 307.3 FIG. 404.2.5 ) (a) FORWARD APPROACH IN AN ALCOVE (b) PARALLEL APPROACH LIMITS OF PROTRUDING OBJECTS POST MOUNTED PROTRUDING OBJECTS GRAB BAR URINAL HEIGHT TWO DOORS IN A SERIES 0 MINUMUM CLEAR FLOOR SPACE 14 HANDRAIL HEIGHTS 11 PROTRUDING OBJECTS 7 SPACING 6 & CLEARANCE 2 DOORS IN A SERIES m 2 0 19 p ° AO. 1 NOT TO SCALE AO. 1 NOT TO SCALE AO. 1 NOT TO SCALE w Z o of P A0. 1 NOT TO SCALE AO. 1 NOT TO SCALE AO. NOT TO SCALE Ld o E [if a Q?�s o 1 1/2" MAX 1 1/2" MAX 3o Mpy, o d t w /2 RADIUS MAX BARRIER PREVENTS PASSAGE OF 4 r..r- `� PARTITION PARTITION 17"-19" (AMBULATORY ONLY) o Z+ `v O N INCH SPHERE WITH ANY PORTION WITHIN 4 INCHES OF THE FLOOR �' I a a o o ° o r- c.- z AREA OF.... .. _.. I U 1 REFUGE ± ° o � E' m� �� o I 4 - L �� O (a) (b) (C) (d) 12" MIN 12" MIN Rn �" - �` I I I °� °� c RADIUS OF TREAD EDGE CURVED NOSING BEVELED NOSING ANGLED RISER ME � ss s 6" MIN U I o n o a�i 3 E o ° (TYPICAL FOR ALL PROFILES) :r �,c, 6" MIN 6" MIN z Iz • p o.O rn L a a+ ul NOT IN PICTOGRAM FIELD Q N ( Q °°� FIG. 504.5 z I rn STAIR NOSINGS ? o . FIGURE 703.5 L - - - - J co 4• MAX `O I� I N n r ° ° c a PICTOGRAM FIELD o 5 c °' T R EA D WIDTH/ N 0 S I N G S RAMP EDGE OPROTECTION EXTENDED FLOOR SURFACE rn N I L - - - - - Q c 0 0 - ° c 18 FIG. 703.4.5 - - - - - N uc� 3 ° c00 0c0 HEIGHT OF TACTILE CHARACTERS a �O /� t °c ° ° 00 Oc AO. 1 NOT TO SCALE ABOVE FINISH FLOOR OR GROUND ELEVATION ADULT ELEVATIONbCHILDREN PLAN 36" 6" V♦ y a° O EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR Z •o O 'y U C � 60" MIN 66" MIN � o c v'� ° ° o FIG. 604.9.5 ° O c m THE LANDING SURFACE, OR SHALL BE CONTINUOUS Ry fn o C O ITO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. pR p WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE •t c U i 20" 20"-25' r ���VVV MAX % MAX 7j/' E / FBI L1 E cc 0 -11 �woa SIDE APPROACH FRONT APPROACH ° 4)v O ° q Z /� WHEEL CHAIR TOE CLEARANCE " WHEELCHAIR ACCESSIBLE WHEELCHAIR ACCESSIBLE _ :t �a y N `00 5 TOILET ROOM TOILET ROOM 0 �- m c 1 �I A0, 1 NOT TO SCALE AMBULATORY ACCESSIBLE (FLOOR MOUNTED W.C. - ADULT Q y ° cJV U E ) (FLOOR MOUNTED W.C. - ADULT) a N Ij COMPARTMENT c - a N L=°� in? % LLL CENTERED t e •~ t N p ° u: C 0 r ON TACTILE s 54" MIN 36" MIN z y=°-' -a� 18 MIN ow 3 w C c 0 3"- o 12" MIN CHARACTERS .�y � FIG. 308.:?.1 (a) FIG. 308.2.2 (b) 39"-41" MIN 24" 12" ® o o ; o o ° o Y FIG. 505.10.1 VERTICAL GRAB BAR MIN MIN >+ aT t'0 m c UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH TOP do BOTTOM HANDRAIL EXTENSIONS AT RAMPS Y12" MIN w j 0 ° d 0 FIG. 703.3.11 FIG. 703.4.4 z a y 0 0 ° N ° U 0 17 b FORWARD REACH LOCATION OF SIGNS AT DOORS POSITION OF BRAILLE • Z z 0- d o + 0 12" 42" Da ;o I w CL 3.O- c ai A0. 1 NOT TO SCALE MAX MIN - [. Lo4" MAX uto cn °'i Ii 10 TACTILE SIGNS11 ® TOP OF GRAB BAR TOP OF GRAB BAR I 56" MIN QZ � 10" MA{ 10" MAX 10" - 24" MAX A0, 1 NOT TO SCALE �1 1/2" MIN co I M 1 1/2" MIN _ - - Q N m fY w N U � I •I mlk � Ld � N NNE 0d X X 18" MIN M M 17"-19" 60" MIN LF z 60" MIN 3 Y V) J Q w m M 24• FIG. 604.5.1 FIG. 604.5.2 � Z N ci SIDE WALL GRAB BAR REAR WALL GRAB BAR � p U p Q � � p\ N � NOTE: X = TREAD DEPTH MAX FIG. 604.7(a) 12' MIN f ' M of f / M 42' PROTRUDINGBELOWGRAB BAR ER (b) FLOOR MOUNTED WATER CLOSET FIG. 604.9.2 'S j SIZE OF TOILET COMPARTMENT NTSSIBLE FIG. 604.9.2 (b FLOOR, MOUNTED WATER CLOSET Lo j FIG.EXTENSION FIG. 5 EXTENSION 3 TOP HANDRAIL EXTENSION AT STAIRS BOTTOM HANDRAIL EXTENSION AT STAIRS GRAB BAR 8c PROTRUDING ) SIZE OF WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT � (a) (b) DISPENSER @ WATER CLOSET FIG. 604.9.3.1 FIG. 308.3.1 4 (b) SIDE WALL OR PARTITION FIG. 604.9.3.1 OBSTRUCTED SIDE REACH FIG. 308.3.2 WHEELCHAIR ACCESSIBLE (a) FRONT PARTITION OBSTRUCTED HIGH SIDE REACH HANDRAILS AO. 1 NOT TO SCALE COMPARTMENT DOOR OPENINGS WHEELCHAIR ACCESSIBLE COMPARTMENT DOOR OPENINGS Y 17a SIDE REACH 13 AO. 1 NOT TO SCALE AO. 1 NOT TO SCALE DOOR SHALL NOT SWING OTHER FIXTURES INTO THE REQUIRED NOT ALLOWED w 9 b NOT USED MINIMUM AREA OF THE WITHIN THIS AREA 16"-18" > COMPARTMENT LAVATORY 17"-25" 8" MIN LAVATORY 25" MAX AO. 1 NOT TO SCALE DISTANCE BETWEEN Q DISTANCE BETWEEN CELL IN THE SAME Q ZO Z L0 - - NO ADJACENTING CELLS� SINGLE BRAILLE CELL I I � z W � z 17- DISTANCE BETWEE o• •o �O I �� J z I z i RARY DOTS IN THE SAME 0• O• 'O• ? �J ~ BLANK CELL SPACE I • I 0 N m CELL •O 00 �O o� ca? .-I Q � w m BETWEEN WORDS • I w m Z 1 I I DISTANCE BETWEE RAISED DOT o I I � O w o Q YYY I o CORRESPONDING DOTS •O �o O o I I I I w a 0 j� t I i I M " FROM ONE CELL •• O 0: •0 BASE DIAMETER I L N • ■���■ DIRECTLY BELOW •O �oOj o� -u Z 0 H Co r J a L - - - - - - - J L - - - - - - - J V •® NO RAISED DOT I- - - - - - U' Q O N Co ao z Lli Z U 4' MAX 59" MIN 60" MIN O_ U Z 6" MAX 11" MIN FIGURE 703.6.3.1 FIGURE 703.6.3.2 FIGURE 703.6.3.3 FIGURE 703.6.3.4 FIGURE 703.3.5 FIGURE 703.4.3 w w �t LAVATORY LAVATORY INTERNATIONAL SYMBOL INTERNATIONAL INTERNATIONAL SYMBOL OF VOLUME CONTROL CHARACTER HEIGHT BRAILLE MEASUREMENT N (n m w p cr (a� (b) (a� (b) OF ACCESSIBILITY SYMBOL FOR TTY ACCESS FOR HEARING LOSS TELEPHONE FIG. 604.9.3.1 (C) FIG. 604.2 w - U � EL - I ELEVATION PLAN ELEVATION PLAN WHEELCHAIR ACCESSIBLE WATER CLOSET LOCATION w O X Ln O x w FIG. 306.2 FIG. 306.3 vT o TOE CLEARANCE KNEE CLEARANCE COMPARTMENT DOOR - ALTERNATE FIG. 604.3 ~ N W o w ~' (FLOOR MOUNTED W.C. - ADULT) SIZE OF CLEARANCE FOR W.C. 16 LAVATORY KNEE & TOE CLEARANCES 9a INTERNATIONAL ACCESSIBILITY SYMBOL 3 HEIGHT OF RAISED CHARACTERS 1 WATER CLOSET 8c TOILET COMPARTMENTS Z A09 1 AO. 1 NOT TO SCALE A0. 1 NOT TO SCALE AO. 1 NOT TO SCALE A0. 1 NOT TO SCALE V) ACCESSIBILITY DETAILS m FIXED SEATING CALCS : TABLE TYPE QUANTITY SEATS 2 TOP 5 10 4 TOP 13 52 8 TOP 1 8 TOTAL SEATS 70 0 U (n w CONTRASTING INTERNATIONAL A 39 SYMBOL OF ACCESSIBILITY SIGN @ MAXIMUM LENGTH OF EXIT ACCESS TRAVEL DISTANCE B 7.8 ACCESSIBLE ENTRANCE DOORS ALLOWED: 200'-0" ONLY; SEE GENERAL NOTE #5 C 68 CONTRASTING TACTILE EXIT SIGN. I I I Q ®SUPPORT I - -- - -- - 1 FREEZER I - W / r� j IE U it r-------- I I 4 4 4 4 r--- ARCHITECT OF RECORD: II N : -- Ln TRAVEL _j o ii I I WOMEN's i i i i i Jj i 'DISTANCE _ � ".. II I- If HJCA MLI I---------COOLER 1! == . I S r — 1Q. ----a III? 1`O 1� 1 15^ --------J� 2 2 2 2 4 I4IT IS A VIOLATION OF TH� Ili TRAVEL DISTANCE _ � � I I I -- I •- 63 I i , LAW FOR ANY PERSON, MEN S I �� 37 -2 �� I I I j S ACTING UNDER THE t` -- —� - 1 UNLESS I ��� I w I - - - I I DIRECTION OF A LICENSED \ I L J i 4 j ARCHITECT, TO ALTER AN ITEM A 20 .'� J---------� I Q I IN ANY WAY. i ._____ B 4.0 I I 11 � 2 w ' , OFFICE USTOMER � I U d" J 4� - ___.__.__-__ a C 46 CREW _ - ;.. W 108 SERVICE O w r7 I- 4 ROOM �• �/ j 100 N DINING Q - 109 ; II Q 101 N 1 !/\ / / \ ILl II 4 I 40 0- w I O F- J W I L �' 1,��. ; }� i01 } Q I I U - _ - z I\ i KITCHEN 8 0 [ J I 105 1 I �c -. 4 4 LLI 00 Z g U I � � � N Gl TRAVEL DISTANCE _ T------� o 0 0 37'-7" I O N N P U `J��`vYYYIIIJ , I A 38 ----- DISTANCE _ - - — COMMON PATH ------- 4 4 ° ° � m � N37'-10" C 3 � , ri :"7-,u�5' i ° u+ ? �r O L s 3p CIL CONTRASTING INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN © - � J � o` �•$ � ACCESSIBLE ENTRANCE DOORS 0 a N E If ONLY; SEE GENERAL NOTE #5 ' I. 0 y 2 o w ou EXISTING KITCHEN u ° o E - a�.r o KITCHEN OCCUPANCY UNCHANGED CONTRASTING TACTILE EXIT SIGN. N � .0 u� ° ,Q,a 17 OCCUPANTS N cV n o 0.00'3" ° 2 c U O —+' 1) ID c l Oar= EXISTING PATH OF EGRESS a o 0 0 c o TO REMAIN UNCHANGED U) r �b c o a°o c° O c U El ° 0 0 p pc++ X•.O_+ M 0 U c OL N C � 00 ►' U Q C 'fl 0 L:� In O'v� p'c m.O OU �- _0- toN� c,a? 0V' 4' 'O r•o' O O c 0 In, W 7 O � u � ° - OV o 0 O of a � c a+ c .F ® O ; O O ° a O >. *' w c LIFE SAFETY • w EGRESS PLAN Q N a° ' y N U U � � n3 °c� ai.�+ W i )-ol) o z 111 O W O U) N N GENERAL NOTES OCCUPANCY ALLOWANCE LIFE SAFETY LEGEND � � N � wQ wo oz Na _' o� q0 1 . THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE ci OCCUPANT LOAD THEREOF AND SHALL PROVIDE A CLEAR WIDTH OF NOT LESS TABLE 1004.5 THAN 32_ INCHES. THE HEIGHT OF DOORS SHALL NOT BE LESS THAN 80 INCHES. MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT — — — TRAVEL PATH 2. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS SIDE WITHOUT O START OF TRAVEL IN Lo THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. ALL EGRESS DOORS FUNCTION OF SPACE ALLOWANCE AREA OCCUPANTS TO HAVE PANIC HARDWARE. 3. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE ACCESSORY STORE AREAS, a POINT OF CHOICE OF TWO PATHS OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, MECHANICAL EQUIPMENT ROOM 300 GROSS 445 2 NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. — — DIRECTION OF TRAVEL Q POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND ASSEMBLY WITH FIXED SEATS/TABLES SEE PLAN - 70 SHALL E'E MAINTAINED BY THE OWNER OR AUTHORIZED AGENT. W 4. THE MEANS OF EGRESS, AND EXIT DISCHARGE, SHALL BE ILLUMINATED AT ANY ASSEMBLY WITHOUT FIXED 5 NET 35 7 EMERGENCY LIGHT Q Z z TIME THE BUILDING IS OCCUPIED WITH A LIGHT INTENSITY OF NOT LESS THAN 1 SEATS (STANDING SPACE) 0 a - N FOOT-CANDLE AT THE WALKING SURFACE LEVEL. EXIT SIGN p z ui 5. GC TO PROVIDE ADA SIGNAGE PACKAGE AND INSTALL SIGNS AT LOCATIONS AND BUSINESS AREAS 150 GROSS 74 1 �] FIRE EXTINGUISHER : O W Z POSITIONS INDICATED IN PACKAGE OR AS REQUIRED BY LOCAL CODES. SIGNAGE ® HER PACKAGE' SUPPLIED BY; FORREST PERMA-SIGN 1 -800-214-8765 M UJ o w a 9292 1ST ST., BOX 588 www.forrestpermasigns.com NEW ROCHELLE, NY 10802 KITCHENS, COMMERCIAL - 0 m z o V) co p 200 GROSS 17 EGRESS LEGEND CD w 6. REFER TO SHEET A0.1 FOR ALL REQUIRED CLEAR & MANEUVERING FLOOR SPACE (BASED ON FULL RESTAURANT STAFF) W a °° ui DETAILS AND ACCESSIB LITY INFORMATION. O U Z A OCCUPANT LOAD AT THIS EXIT 0 0 x o x cn UJ En N Ld o wo TOTAL OCCUPANCY ALLOWANCE 97 B REQUIRED EXIT WIDTH d Z o 0 TOTAL ADA SEATS REQUIRED 4 C PROVIDED EXIT WIDTH V) CODE ANALYSIS m GENERAL NOTES 1. ALL DIMENSIONS ARE TO OUTSIDE FACE OF SUBSTRATE OR MASONRY UNLESS OTHERWISE NOTED (FIN = FINISHED DIMENSION). INTERIOR DIMENSIONS ARE TO FACE OF GYPSUM BOARD. SEE EXTERIOR ELEVATIONS FOR WINDOW TYPES. 2. GC TO PROVIDE ADA SIGNAGE PACKAGE AND INSTALL SIGNS AT LOCATIONS AND POSITIONS INDICATED IN PACKAGE OR AS REQUIRED BY LOCAL CODES. SIGNAGE PACKAGE SUPPLIED BY: FRANKE/S2K WWW.FRANKESUPPLY.COM EMAIL: FS-FRANKESUPPLY.US@FRANKE.COM 1-800-423-5247 z 3. MAXIMUM OCCUPANCY SIGN TO BE POSTED PER LOCAL CODE. SIGN tc- FURNISHED AND INSTALLED BY GENERAL CONTRACTOR a- 4. ALL FRAMING LUMBER (SILL PLATES) IN CONTACT WITH CONCRETE SLAB c� SHALL BE PRESSURE TREATED IN ACCORDANCE WITH IBC N 5. ADJUST ALL PEDESTRIAN ENTRY/EXIT DOOR CLOSERS TO A MAXIMUM OF 8.5 Ibs. (EXTERIOR) 5lbs. (INTERIOR) OPENING/CLOSING FORCE. IN ADDITION, ADJUST CLOSERS TO ACHIEVE A CLOSING TIME OF 5 SECONDS FROM 90 DEGREES TO 12 DEGREES. IF NOT ACHIEVABLE, REPLACE DOOR CLOSER 6. GC TO COORDINATE ALL REQUIRED BLOCKING FOR WALL HUNG EQUIPMENT, SHELVES, ETC. FOR PROPER INSTALLATION HEIGHTS 7. ALL KITCHEN EQUIPMENT IS EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 8. ALL HAND SINKS, VEGETABLE AND 3 COMP SINK ARE EXISTING TO w REMAIN U.N.O. Q 9. GC TO COORDINATE THE REMOVAL AND RELOCATION OF THE KITCHEN EQUIPMENT WITH THE KES AND ACM. 10. REFERENCE THE KITCHEN PLANS FOR FINAL LOCATION OF THE KITCHEN EQUIPMENT. - - 11. GC TO COORDINATE ALL FINISHES WITH THE ACM. 12. PREPARE ALL EXPOSED SURFACES AND STRUCTURE FOR APPLICATION ARCHITECT OF RECORD: A ................................................ ........................ — - OF FINISH SUBSTRATE 13 REMOVE ALL DEBRIS FROM BUILDING & SITE DISPOSE OF INPO ACCORDANCE W/ STATE & LOCAL CODES. �'�>'Ftfs c� I� - ....._...... .-_ �j' 14. PROVIDE TEMPORARY SUPPORT & BRACING AT ALL WALLS DURING SUPPORT /: ` DEMOLITION. C. 3 �.._ j`�. N 15. ALL NEW HAND SINK LOCATIONS SHALL HAVE CEMENT BOARD BACKING104 r _� L _..._........._ --___.. _.. - .._.... - .. _.._.....,_ _;....._............................ ........: .:...._.... ........................................ I }..................................................�_. _ ......... :.:::::::.:::::::::::::.::.:::::: 48 IN HEIGHT A.F.F. 1. .t.. . ..................................._L, ...................._....................._....._........._....................... _ ._ _. �: _._ 1 1 _.. -__-_ . . . _ � . - 16 POWER PANEL LOCATIONS WITH i FREEZER � '....., ,..., ��...... ' �4as77 COORDINATE TEE (STING AND NEW I I -... - i I i ELECTRICAL DRAWINGS AND ACM. <�F ti �ti —Ij - `' I; I i 17. ALL PLYWOOD SHALL BE FIRE RETARDANT TREATED. I i �. i -' iiis . ..1.............................................:........ ...................... (i II i IT IS A VIOLATION OF THE _ I_ �. j............................... ...._..._......_.:-................................................................ ...........................;.................................................................._......... f LAW FOR ANY PERSON, UNLESS ACTING UNDER THE j ✓ I) NOTE ; 'j j i DIRECTION OF A LICENSED ..................... - -- RESTROOMS ARE NOT IN SCOPE ARCHITECT, TO ALTER AN ITEM I: _ • : 'i KEY NOTES IN ANY WAY EN'S i WOM i•. r j 102 NEW MODULAR FRONT COUNTER BY OTHERS V! _ - - > V.I.F. _^ CURATED WALL PANEL AT HLS/HLZ; SEE DETAIL w.................: (' �* - r(_-!° !!�; �� /A1.2a FOR INSTALLATION I J i 1 .................................r..................... _ w ,- .r.. I (..... I ��, I ..... ..............i.., ....... ., COOLER _. ............. ............. q _ �... r NALD S AREA :. o ...................._�. mot.• ' , CLO. ` ;�'" ;r WALL TILE COORDINATE WITH THE MCD i t DF U w� 1 10 I CONSTRUCTION MANAGERFOR FINISHES I 1 i SUPPORT 1' ........ ........................_..................._- ...._ ..1.....- � .... _. ....._ i FLOOR LINE - CHANGE IN MATERIAL ................._................................ ... .. ... .. - .. ............. ............. y ............ i 1 _..._.._.... `... 104 r i .. ._._... .._.. L - --- -- --� _._...........: fit...... ....._...........: --t--- I - ' - K .............. ..... il........._..._....1 I jj `-- f 2 FRP FIBRE REINFORCED PLASTIC. COORDINATE WITH THE f �" ;�. ` RELO. ' ' MCDONALD'S AREA CONSTRUCTION MANAGER FOR NOTE ............ � .. �� r i El FINISHES B.O.H. IS NOT IN SCOPE MEWS " . ~v lv o E ( 1. it m 103 1'-9" 2'-2" " I GOLD PANEL. METAL: PROVIDED BY S+D o N ° - _ - i — �z C — 9, 1„ r GP W P r I 1 1 o Q I V.I.F. o ° _.....::.::.::..............................................._......................................................................._. ...._.............. .� r 1 1, ,; �.: RELOCATED ORDERING KIOSK. COORDINATE THE EXACT W „ W= E oo n - i I. GP �� �ti'. ._............. ` l a L a�v°a U ' .. I �\ J:..........._.... M:.. f..;l LOCATION WITH THE McDONALD S AREA l I KE a , a ; CONSTRUCTION MANAGER. REFERENCE T KIOSK -^ CREW ' ® `-` -------'-__J _ I' AND GUI GUIDELINES ON GN1.OE o °' _.ti`_._..._.. --___ - - - m ::..:............::: ROOM KE DF ❑ I o a� o o v EXISTING DINING TO REMAIN ... DENOTES NUMBER OF KIOSKS L ,� ° -- 61 11091 , �� j .., 2 UNLESS NOTED OTHERWISE DIN0ING - i 1', ' . s. ' °a `� ° o �.;_....... ................... .................... .� •c a a o o�. ( ....._..........---:..._-.:...:............................................. ... . 108 i MB :�..._... NEW 3 -0 CENTER ISLAND BY KES W RELOCATED ci a a� a� �> > Ii ❑ ® E o L 05ev o C ACM AND OWNER N a `o v° ...... TYP. _ _ L .. „ i KE - ;%' 4 OPERATOR FOR FINAL ERIFY H J ►' �.:: I f - O 00 � D1 I Q i'"�� OPER _ > �, �' t "1 ................................. ° ° i tID E : ........ I I ti . 1 co aN v�i a m QUARRY FLOOR 'I TILE ; %- i I NEW FCB BY OTHERS. VERIFY WITH ACM AND a o , L �+• .� - I OWNER/OPERATOR FOR FINAL LOCATION c ° L ` u . *� c m u j �:..... .....__......._................................................ 1. r/• 2 c m o 0 i TILE KE .._. ;._. ............................_. ........... . - USTOME I _..........................:..._.......... _ .. o L CUSTOMER FL j �� t j I KE SERVICE ( " �....._., i o V♦ �«- 0 u ° c °'a r.............. -' i RELOCATE COMBO SHAKE MACHINE W MCFLURRY N c o °'- .- ° ` L KITCHEN j 100 ) i i / v c r ! KE BLENDER. E U N - «� cLov�• / 3VERIFY o j DF BRACKET BY KES. EWITHR ACM AND OWNER 4 C I ; ;. - ifi OPERA F FINAL LOCATION o a. cc ............ I i L �( ° - _.. i �.,._.=ail OPERATOR OR F � � N ,.:::.............. A I NEW 48" DIGITAL ASSEMBLY CART W FRIDGE BY KES. �' °_ d I?I�lII}tI , VERIFY WITH ACM AND OWNER OPE ATOR FOR FINAL o v~ c a� 1 / o ° l I � Z I �_• L13 ._:i _ J 4 LOCATION o ° L . ............................... � I •S� u ..... ..... ..i. J ,, 1.......... o. , "�'__.:. .........................i::::::.._...................._.._........................_.._......_..._...._...................... ...__..._..........................._..... .........__ Lo i i' n » U •N ° ` C~— � ,..t:.... .. . FRP \ / ---- ---' - KE NEW 14 X30 TWO—TIERED MOBILE OA STAGING CART BY a N u w - - —_ , - •N KES. VERIFY WITH ACM ANDMOWNER/OPERATOR FOR FINAL O p pcu EXISTING KITCHEN TO REMAIN 5 LOCATION o� a ai L UNLESS NOTED OTHERWISE cP ° o o " '�° L a ♦ o V a� , N 1..............................__1..._..........................._.._..............._................. _ J >...._......__...__......_.._................................................ NEW c ° �. E SURFACE MOUNTED MENU BOARD, r.° °, Q ..........................._ j ! ---- --- --- " c 1., oo I , Me ECTRICAL 3 w._ f �\ ..:::: SEE EL .� p.0 O - ................._................. .............................. O L f , ie ........i if— ..... 'L N 7 O r- �•. .J d fn y U U _.,1: C...Y..t._...:. ., o t m ....................................................... j N L+. N O i ( > ��1._.._I,' \:.'Y.•�I ,,,� i 1 W .0 L• O L p t ............................ I .................. ..................... t................................. ___........ i : ------ .. .............................................................................................................................. ...............................r_......_....._...__.._....._.......__.............................................................................._................_.........__..........._.................._..._...................................................................................._....._........... . M mo 00 inW � O wr O w N o (!1 N N � �t Ln O 3 `1 V) - Q wn aM (4)-0.157" DIA. o f N = a \ 6 o Of cn HILTI X-U P.A.F. z N a FROM TACK TO B.O. CHORD AT W EACH JOIST v Z N CONT. SLOTTED ( I o STRUCTURAL MEMBER - to DEFLECTION TRACK BOTTOM CHORD OF JOIST W/ 2-1/2" LEGS OR BEAM � LATERAL �o< CONT. RUNNER CHANNEL Y BRACING TO I FIRESTOPPING AT CEILING STRUCT. ABOVE z MTL. STUD PARTITION TYPE: ® 4-0" O.C. ALL PARTITIONS TYPE 'A' LEGEND 1/2" GYP BD I..-�� CL UNLESS NOTED OTHERWISE z tz OR PLYWOOD I r{ SCHEDULED „ „ Q 0 Z N PARTITION TYPE TAG SEE 2/A1.1 A = 3 5/8 z o w B BACKUP EACH if { SIDE AS "Al"= 3 5/8" W/SOUND BATT 0 0 - P m o c n V) af O DOOR TAG - SEE DOOR & INDICATED ON BS = 6" W w o Z HARDWARE SCHEDULE ON A1.1 FINISH SCHED � KEY NOTE i �, "B1"= 6" W/SOUND BATT INS. L� m w a ❑x BOTTOM 12" I `:r "C" = 8" ~O ? o co OF BACKUP TO "C1"= 8" W/SOUND BATT INS. Ld 'n 0° WOOD/METAL FRAMING BE CEMENT I .%" FLOOR AS "D1" = SEE DTL 7/A1.2a z o z ,n BD. - MIN. I SCHEDULED a w EXISTING CONSTRUCTION 1/2' ABOVE o SPACING: 16" O.C. w N v i ,= ON W o w v~-i o '. SLAB ' .:> � � LOAD BEARING: 18 GA. � NON-LOAD BEARING: 20 GA. 1 FLOOR PLAN 2 INTERIOR PARTITION z A1 .1 4 = i -o A1 . 1 3/4" = 1 '-0" METAL FRAMING cn FLOOR PLAN GENERAL NOTES ' 1. EXISTING EMERGENCY LIGHTING CONFIGURATION TO REMAIN, UNLESS OTHERWISE NOTED. 2. CEILING PLAN PROVIDED FOR PERMITTING PURPOSES ONLY. PLEASE REFER TO DECOR DRAWINGS, UNDER SEPARATE COVER, FOR FINAL CEILING PLAN AND LIGHTING LOCATION. 3. RELOCATE EXISTING CEILING MOUNTED AIR DEVICES TO ACCOMMODATE DECOR CHANGES. CONTRACTOR SHALL EXTEND DUCT, AS REQUIRED, TO MAKE FINAL CONNECTIONS. z KEYNOTES 1= ❑ NEW ACOUSTICAL CEILING TILE - COORDINATE WITH THE v ACT Lu McDONALD'S AREA CONSTRUCTION MANAGER FOR FINISHES o A ACT ACOUSTICAL CEILING TILE - VINYL FACED COLOR: WHITE - SEE ROOM FINISH SCHEDULE. MATCH EXISTING CEILING AV BH BULKHEAD FRAMING; SEE DETAILS ON A1.2a "EXIST" FOR WHERE OCCURS DARK CURATED VIEW PANEL: Li CP COLOR: WILSONART - STEEL MESH 4879-38 I o LIGHT CURATED VIEW PANEL: COLOR: WILSONART - FASHION GRAY D381-60 NOTE: GC TO RECEIVE CURATED PANEL MOUNTS FROM S&D VENDOR FDF G.C. TO VERIFY WITH OWNER TO REPLACE/RE-PAINT, ETC. ARCHITECT OF RECORD: LAY-IN DIFFUSER COLOR: MATCH ADJACENT CEILING. w ...................................................... ........... .. .................................................................................. \—"EXIST" FOR WHERE OCCURS �`��1G �� ti ��'fi i � c cB EXISTING GYPSUM CEILING LIGHT: TIE INTO EXISTING LIGHTING CIRCUITRY. VERIFY .. : I L1 B.O.H. NOT IN CONSTRUCTION, SUPPORT SWITCHING REQUIREMENTS W/OWNER. CONTRACTOR TO CEILINGS AND HEIGHTS 104 i VERIFYILOADON EXISTING CIRCUITRY DOES NOTEXCEED ` ��°ad1r� � EXISTING TO REMAIN, TYP. _) S °�MAXIMUM RATING. NOTIFY ARCHITECT OF ANY CONFLICTS. FREEZER ; CENTER FIXTURES IN CENTER OF ACOUSTICAL CEILING I IT IS A VIOLATION OF THE 111 ! I ® TREATMENT, U.N.O. CONTRACTOR SHALL PROVIDE SUFFICIENT LAW FOR ANY PERSON, ...... EM LIGHTING & ASSOCIATED LED INVERTERS FOR EGRESS UNLESS ACTING UNDER THE LIGHTING PER LIFE SAFETY/NIGHTLIGHTING AT FRONT DIRECTION OF A LICENSED ARCHITECT, TO ALTER AN ITEM IN ANY WAY. 1 RESTROOMS NOT IN i COUNTER AREA. V.I.F. CONSTRUCTION, CEILINGS AND WOMEN'S -......... � DIGITAL MENU BOARDS. SEE ELECTRICAL DRAWINGS. HEIGHTS EXISTING TO REMAIN, 102 � MB 7 = Z �- .... ! TYP. ID .._......._..................................... -._..................._._............... POWER & DATA FROM ce w CEILING FOR RELOCATED SELF-ORDER KIOSK G B �................... :..... (COORDINATE FINAL COOLER </ o JAN'S LOCATION WITH THE ACM) l ` 1 10 ! EXIST. C L0. j 115 SUPPORT v� 0 .....................................................................__........._._....---.._.... .. r 4.............................................. -1..................... EXISTING CEILING AND GRID TO REMAIN. r - . .. . MEWS PATCH AREAS OF CEILING WHERE LEGEND °° - - GB 103 ' WALLS/DECOR ELEMENTS WERE a g o a o Zoo EXIST. 4 REMOVED TO MATCH EXISTING N z 2 X2 MECHANICALLY SUSPENDED IL w O v y i ACOUSTIC CEILING TILE (ACT) j I ! DINING ! co w v �o D CREW 0 101 i v ° �, N ROOM ! i a d ° v c w `.2 ° I o S' 'op omoC.c 109 ! o c aavm � ur 4 X2 MECHANICALLY SUSPENDED 0 a E' OFFICE MB DF CUSTOMER pININO WORK IN THIS AREA; ! ACOUSTIC CEILING TILE (ACT) C. ow.°? ao 108 i TYP RELO. SERVICE �,NG NOTES ` o o TYP. EXISTING TO REMAIN, U.N.O. - v 3 v E o c ( ................................................ ............ � N = - fA i DF 100 0 ., o o� N` aN� 0 � � �, uc a� ►- � u SUPPLY AIR DIFFUSER E RELO. o o TYP. o t� „ o ACT 8'-9" coo - v c N O C v v ;O O O L t U.2 O O C A A.F.F. MATCH EXIST =_ _� (V.I.F.) N + h.L°, u v ay v pp. BH RETURN AIR DIFFUSER � o E c I L1 v c um vuo ° V C NL N ANEW TYP. v' ° u u 3 cc .c°- �� cwaoa=i 1.2 DUAL HEAD EMERGENCY LIGHT a � �� N"o KITCHEN ! J � �° Fv � �,0 .. v- U+' N ° V C N O O) 105 6 ® 0 n N•- cP 1 2 EXIT SIGN 0 M. KITCHEN & BOH NOTES ° 0° S. y "' n o .................. • NO WORK IN THIS AREA; �,� �w �,a-6 EXISTING TO REMAIN, U.N.O. r �':� FIRE SPRINKLER c- x �, BH ACT EXIST AV o ® L. �; 0.0202 Q Nmvmo � N N O = U) d V_ U d N O'L N 8 -9 2 A.F.F. MATCH EXIST W c i•- o OL �t 0. (V.I.F.) Z w 1 1 ^I i a.l ! m04 � 00 mw Z) o wLn O N 0 (n 04 �t .. ................................................................................................................................................................................................... ................. ................................................................................._......................................................................_............_.......... (n _.__.....__....................................................................................................._....................................._..._.._.........................................._..............................................._............_......-..................__....._..._..........._._................_........................_.............._..................._........................................................................... wLd 3 Y Ln J w Q w r ap j1 o C a; o0 c3U N Q cn Z V N Lo Z Y U F- Q W Q Z � Q 2 z N 0 z w O Q J Q w � — o: z 0 W 0 Q LL m w a L� w O O z 0 o -) w °' L� j z z Z I� a w w N Ln w or O X w v w N W 0 u) o 1 REFLECTED CEILING PLAN 0 Al .2 1 4" = 1 '-0" ZA� o V' REFL. CEILING PLAN m z O E-- a. U V) w 0 w Q I � I ARCHITECT OF RECORD: Vic ` 13Ax'Cf h to •;I sPgr Cf441T7 OpEv Nib IT IS A VIOLATION OF THE . LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO ALTER AN ITEM IN ANY WAY. • i = a Z L , I I I o I I u CEILING BOH i i CEILING SA7-1 J I I • 1 I I I m o E DIGITAL MENU BOARD o 2 o g EXTEND PLYWOOD TO UNDERSIDE � E PEERLESS SMARTMOUNT ` I I 0- `- a o OF EXISTING ROOF DECK UNIVERSAL FLAT WALL MOUNT; B JOIST INSTALL PER MANUF. REWS ELEV. VARIES o7-7 v L- 4 Cc o c ao.o m V WALL FINISH PER I I �, �` `r N ° ` a+ o ° RM FINISH SCHED n ° a 0 PROVIDE FULL \�: I��; o o `� v _ 3 ,._ ox DEPTH BLKG I° I 3 5/8" MTL. STUD @ 16" O.C. 0° " ° 'a° E a ® EA. SIDE I i VERT. STUD & BRACE TO Q In I OF JOIST I I ATTACH W/ (4)-SCREWS @ 48" n "-°o 2 I I 3 " DIAG. MTL. I I O.C. ATTACH INTERMEDIATE o r_ o o.° `° ca I •• I I STUDS W/ (2)-SCREWS p = 0 I BRACE ® 48 O.C. ° ` p § I ATTACH GUSSET TO i i rrop � 0oo BOTH BRACE AND I I 6 CONT. MTL. STUD N ~' , °.0 a° DF 1/2" PLYWOOD; BY GC VERT. STUD W/ I I ` c p E.N E ° ° coo ° a0io I I ° o"'' x'." (3)-SCREWS I I o f ° Lo ;'` W CEILING AS SCHEDULED, TYP. o -' � ° ° N ?V Q C V)• ° C D OVER YzPLYWOOD— 3 5/8„ MTL. VERT. STUDS @ dV Z)-° ° t 16 O.C. N N r= pV °Vvo°i Gw� METAL STUD WALL L y` ° CONSTRUCTION EXTEND DRAFTSTOPPING ° 6+, °a°° E SHEATHING TO UNDERSIZE OF ° o '° 9' '° a c'� ROOF DECKING a,o Q,a� CONT. MTL. TRACK o .3 "-� c"3 w o B „SOFFIT 0 ® L at °o v °C 7 SURFACE MOUNTED MENU BOARDS 6 SECTION © VALANCE WALL s —s A.F.F. Q N r- w F_ CL; c� ai.L A1 .2a 1 = 1 -0" METAL FRAMING A1 .2a 1 "=1 '-0" REFERENCE ONLY a � w _ )- Q CNNm Ld N 0 I.C) m O w 0 0 V) V) N N � � Ld O BUILDING STRUCTURE 0 - o a � o � N ROOF DECKING 1-5/8 UNISTRUT © 12 O.C. 2 z N 0 MAIN TEE ROWS STAGGERED ATTACHED TO SPLICE SIDE MOUNTING LEVELING WIRE HANGER BOTTOM CHORD OF ROOF JOIST (2 COUPLING LUG BY FIXTURE MFR. MIN. INSTALLATION BY U ) N DETAIL AT WALL (OCCURS AT 01 RANDOM) ELECTRICIAN AS PART OF WALL MOULDING 1-5/8" UNISTRUT ATTACHED TO #12 SAFETY WIRE OR EQUAL FIXTURE (2 PER SIDE) CAN BE "C" OR "L" Z 1-5/8 UNISTRUT POST BASE. TIED TO SAFETY WIRE O + SUPPORT HOLES & z J FASTENED TO BLDG. of STRUCTURE. MINIMUM CROSS TEE-- MAY BE "A' i w + (2) SAFETY WIRES Q 1-1/2" OR 1" HIGH i', SECTION "A-A" FIXTURE VARIES w + PER LIGHT FIXTURE / CONNECT TUBE STEEL BRACKET TO AND MAY BE 2'-0" OR A WITH MFR PLYWOOD WITH (4) 1/4 ZINC 1" PLACED AT DIAGONAL �`- 4'-0" O.C. ? BOLTS. CORNERS TILE OPENING �D_ 3/4" PLYWOOD BACKING Q 0 w N + z CEILING AS SCHEDULED O Q cn 0 NOTES: U) x MAIN TEE-48" O.C. ; 1. AT EACH END OF LIGHT FIXTURE AN INTERLOCKING CROSS TEE OR 0 Z O w 0 MAX. SHAPE AND ( :�a:-: .;;,;,,;Y:,-: . :.;,.sue: f:' �v:;;"�:;�I,,�:',-::;�•� ,t.:;� = o a H EXPOSED T-BAR CEILING I i- m w F LOCKING BAR MUST BE USED w a DESIGN AS i4PP'D.) 2. THE TOTAL WEIGHT OF A LIGHT FIXTURE AND OTHER EQUIPMENT J F- w w THE RECESSED FIXTURE Q LIGHT FIXTURE Z O o (AIR BOXES, ETC.)AND CEILING MATERIAL SUPPORTED BY THE MAIN NOTE: U' 00 12 GA. GALS HANGER WIRE MAY BE SUPPORTED BY N SAFETY WIRE Li z Q 0 NOT TO EXCEED 4'-6" O.C. BEAM MUST NOT EXCEED THE ALLOWABLE DEFLECTION OF 1/360 OF z_ CURATED PANEL MOUNT PROVIDED SUPPORT HOLE, ALL WIRES ARE TO BE z O z THE MAIN TEES SPACED IT'S SPAN. DEFLECTION DATA MUST BE FURNISHED AND CERTIFIED TO G.C. BY S&D VENDOR TAUT WITH A MINIMUM OF 3 F= w w ALONG MAIN RUNNER. SEE 2'-0" OR 4'-0" O.C. BY THE MANUFACTURER. TYPICAL TIGHT TURNS AROUND SELF � w 0 SECTION A-A. ATTACH TO — 0 M � 3. SURFACE OR PENDENT FIXTURES MUST BE INDEPENDENTLY CEILING AS - TYPICAL O X w 0 w W EXISTING BUCK IRION cV LIJ 0 o SUPPORTED FROM FLOOR OR ROOF CONSTRUCTION. SCHECULED 5 CEILING GRID DETAIL 4 ACOUSTIC CEILING TRANSITION 3 1 LIGHT FIXTURE SUPPORT DETAIL CURATED PANEL INSTALL DETAIL 1 .2 N.T.S. FOR REFERENCE ONLY • a 1 .2 N.T.S. A1 .2a 1 1 /2"= 1 '-O" COORDINATE w/ DECOR A1 .2a 1 1 2 = 1 -0 ZCIO CEILING DETAILS 4'-Oy4" 01 4p-Oy4" m 0 0 J J O O 77 EXISTING WALL CONSTRUCTION cP Frc--p 0 c� z , z J DRIVE-THRU PIE FRONT _1 VIDEO DISPLAY COUNTER w U MONITOR MONITOMDEC)R W C) I I ED z Q -x O _ -J = I I \ DF OVER 1/2" PLYWOOD � o- w > Y NAPKINS w > � Y \ I I O D_ LLJLLJ U ® > Q - > Q w W W z W _W Z 00 I i W LL F- cD W LL. I- I I I �- �' V) BAGS BAGS MEAL AG BAGS BAGS U' X I I z W �,GS 1 w I I 10 5 Ln o - o o - O I I PEERLESS SMARTMOUNT 4.4 4.4 m W m UNDER S m w m UNIVERSAL FLAT WALL MOUNT; 3 BOY TOYS GIRL TOYS TOYS F" "T_ 0 o INSTALL PER MANUF. REQ'S I I A4.4 1'-9" 2'-2" W I I V.I.F. GOLD PANEL 00 i i DF V.I.F. BY DECOR o CENTER ISLAND I I 4'-0" 4'-0" I I DIGITAL MENU BOARD ARCHITECT OF RECORD: Lp A — HEATED LANDING STATION B — HEATED LANDING ZONE � i I SERVICE POD ---;-��; CURATED VIEW PANEL ELEVATION 1 I 3-5/8" METAL STUD i FRP DF BY DECOR 6 PARTITION IE VENDOR, A4.4 1 2 = 1 —0 INSTALL BY O I SURFACE GC 34" MAX. A.F.F.) .M I.._....... MOUNTED of DIGITAL w rT _ c� ALIGN VALANCE WALL FINISHES WITH I I � `f Or 4, F GOLD PANEL ACCENT WALL FINISHES. PROVIDE I I I I I MENUFl- �-=- „ I I „ :....�.... 2 BY DECOR DF 5 CONTINUOUS Y2 PLYWOOD ALONG 7 I I DF OVER 1/2 PLYWOOD BOARDS IT IS A VIOLATION OF THE 4.4 ENTIRE VALANCE/WALL FOR DECOR 1.2 I I 0 LL ABOVE A4.4 LAW FOR ANY PERSON, FINISH AND MENU BOARD INSTALLATION. I I I I UNLESS ACTING UNDER THE I I ! I > DIRECTION OF A LICENSED i 00 I I ❑ ARCHITECT,AN TO ALTER AN ITEM B/ CEILING I I 7 % ..---- % 4.4 ------ -- ---- --.----- EE RCP I z o S µ � � I ------ •'i I I I I T � T -I N O � Z I I o 0 0 o i i i = I I 3'-4" 2'-2" a - 0 a W I I I I I I I I ) 1 ( 4.4 i� ( o a 0 I . .'l I I I I I I I ORDER . .. .. .. .. . V I:'.'•'•'.'. .'.'•'•' I I O0 e me 00 3 SURFACE MOUNTED MENU BOARDS READY awA BOARD ? I I . .. . .. . . . . . { PICK UP POD :I' I I I I I•• •• •• •• •• •I I I I I I A4.4 3 4 = 1 —0 g BY DECOR -L� i i'.'.'.'.'.'.'.'.'.'. .'i i j 1 7 -10 1/2" O �� 1 I.. .. .. . ... 4.4 VENDOR, o INSTALL BY CL L--------L------=-I -------J ? D I I i t V.I.F. X O T GC 3 w i i•.:.......:......... .I I \ / :....._' - .._. ! A.F.F.)4 Y m U I I . .. . ...... . I I \ / DF "� U N o E W I f . ... ...... . ! I ; — 0 ' 8 0 w I I. . . . ... ... .I I \ it I i D n Z m of N I L. .. . .. .. .. . I oo - OPEN/TO DF 21-299 44 v - r___ o KITCHEN ---T-F- ==� :I.....--- :,.... ,.. ........ I $ LL N / L J -_: L J C=-7 CORIAN COUNTER COR f 1 6 �_ _ ------- c� I I I ...................................:. .............__..... NEW o v a >- zA4.4 VALANCE AT r o 8 "' °N r r`+ Z) v I I I I DINING SIDE coR { 6'-8" A.F.F. ° v o o m I / \ I I I �, B - - - t-D I N ° o m ° ai v >j c� J O II EXISTING '� a U p ° ICIc 5�'t �o a I t I I PICK-UP/DELIVERY CABINET: s I!' O ..................1..... { I A N \ �..� ° ` a:3 VLA CEAT w 3/4 ADX PLYWOOD f =- vim; 6'-8" A.F.F. "� LL: J a o `v° ci a o I I I I I WHITE LAMINATE INTERIOR Z I -- - ----- - - - - T/FINISHED 5MM WHITE PVC EDGES TYP. — �`� I o o 3 � m t Y T FLOOR I a a ELEV. + 0sl� '-0" PICK-UP SIDE: : : -.... -- — - ".. ................... . DF TILE COVE ADJUSTABLE SHELF FOR °---- E---ocl) OUTLINE OF PICK UP QUARRY TILE OUTLINE OF SERVICE ORB SCANNER I z z N t v v+o BASE - I I a... c� U o o*' v c POD © FOREGROUND COVE BASE POD ® FOREGROUND 0 I'' ;: J J `�' ° c-° 3 c °' (L) ADJUSTABLE SHELF I r � Q ¢ @ ° -+• c ov MOUNTS I. INTERIOR ELEVATION INTERIOR ELEVATION FINISHES °' ° "° ° 10 7 ' N I \ ♦^ crow. A4.4 1 2 = 1 -o A4.4 1 2 = 1 —0 DELIVERY SIDE: : CP 1 =/ �'c E ° ADJUSTABLE BAG SHELF o c c°� c o u o ° CURATED VIEW _� ° a� "_ "= a� ®6" AFF - PANEL @ HLS/HLZ o `O V`o :3 -=------------------ » w LAMICU ? 'N p C w F O a . Nw Cw V+' 0 N ` ° V 0 ° N N � V c' orntE v ° o w o au N U C•_ O . O 6 ORDER SURFACE STARTING POINT FOR o H ,13 BOARD DIGITAL MENU PLACEMENT NTU OF INDOOR wo 3 �c c°'F w 1.2 READY 4 PICKUP POD SECTION BOARDS DMB & RECESSED FRAME A4.4 1 = 1 —0 W ® � �� �, � y � a) o —1 Of o aov . Nuu 0 o -0. c- aim 1 ENLARGED CUSTOMER COUNTER PLAN ORDER � N O A4.4 1 2 = 1 —0 DF I I 24=- READY Q N o �'� BOARD DF DF m 0 Q p m W � O w � o L MENU MENU MENU I I a N_ J Q w Q °�� i KEY NOTES McDONALD WITH _j 'SCOORDINAACM PRIORTE ALL TO SINSTALLATION O \ J F- Q 0. EQ. E i Z V) LD PANEL PANEL 01 GOLD BYi DINING _ _ ❑ DECOR FINISH: z � BY SIDE DF PORCELAIN WALL TILE: EUROWEST ., DECOR w w Of 0 DECOR I COLOR: NOIR 4"x12" PATTERN: STACK BOND LO 0 w v w z 4 2 - GROUT: MAPEI - 47 CHARCOAL -JOINT TO BE o vwi o V) Q A4.4 A4.4 rill SERVICE POD Yes" MAX. m OPEN TO "ao m 00 in FURNISHED BY R CORIAN:KITCHEN Lo Z 0 COUNTER DECOR VENDOR ❑ V) W SIDE I / I I I I INSTALL BY GC COLOR:CORIAN CAMEO WHITE BY GC CD m W o KNEE I B = CORIAN DEEP TITANIUM BY GC z } WALL BY I I II m m OR I DARK CURATED VIEW PANEL: 0 -1 GC A I cP COLOR: WILSONART - STEEL MESH 4879-38 Z Q i 1 i I I LIGHT CURATED VIEW PANEL: Q Z N N DF I I o COLOR: WILSONART - FASHION GRAY D381-60 z w / \ w N NOTE: GC TO RECEIVE CURATED PANEL MOUNTS — ��' x �i a D V) 0_ / Y DF DF I FROM S&D VENDOR LL � Z PICK UP ORDERING of I I FRP FIBERGLASS GRAY NSMOOTH, CLASS C,FORCED PLASTIC F.075 m W o U.LAM �� M Z A6 1REFER TO ROOM FINISH SCHEDULE FOR NSTALLATION OCATIONS. FOR 0Lli C� -' ~ Do LO OUTLINE OF- PICK UP POD BY SERVICE POD BY N DO DECOR VENDOR, 3-5/8 METAL I Y ORDERING, CONTACT KIMBERLY LAWSON z 0 0 z PICKUP POD ® F DECOR VENDOR, REMOVABLE LAMINATE ,n FOREGROUND INSTALL BY GC INSTALL BY GC STUDS ® 16" O.C. I Kimberl Lawson© anolam.�com I,r� a W w LO KICK PLATE Kimberly-Lowson@panolam.com 34" MAX. A.F.F. 34" MAX. A.F.F. (n a o { ) { ) 1-866-925-4377 N _ SERVICE POD AND PICKUP POD PER PLAN QUARRY TILE DINING ROOM TILE �_ X w Ov w scH DARK SCHLUTER: 1/2" QUADEC Q100TSG ~ N W COLOR: TUSCAN PEWTER LIGHT g INTERIOR ELEVATION g INTERIOR ELEVATION 5 SECTION AT GOLD PANEL 2 FRONT COUNTER SECTION COLOR: SATIN ANODIZED_ Z 4 A4.4 1 2 = 1 -0 A4.4 1 2 = 1 -o A4.4 1 = 1 —0 A4.4 1 = 1 -oA 4 • In COUNTER DETAILS I I I m -CERAMIC OR PORCELAIN WALL TILE rr I I i I 1/4 GAP CERAMIC OR PORCELAIN WALL TILE �-FLEXIBLE SEALANT AND COMPRESSIBLE BACK-UP. HIGH PERFORMANCE CEMENT GROUT WHEN REQUIRED PORCELAIN FLOOR TILE LATEX-PORTLAND CEMENT THIN SET MORTAR PORCELAIN TILE INTEGRAL COVED HIGH PERFORMANCE CEMENT GROUT TILE BASE WITH A LATEX-PORTLAND CEMENT THIN SET MORTAR RADIUS QUARRY TILE LATEX-PORTLAND CEMENT THIN SET MORTAR I COVE HIGH PERFORMANCE CEMENT GROUT EPDXY GROUT, 100% SOLIDS I O CEMENT BACKER BOARD MODIFIED-PORTLAND CEMENT THIN SET MORTAR CONCRETE, ON-GROUND I �_ CONCRETE, ON-GROUND CONCRETE, ON-GROUND VAPOR RETARDER MEMBRANE V) o . . :..........: ..... . ......:::: ...........:.. . .:: WOOD OR METAL STUDS d ...,.;.;4;:•_. ..,ae. • p d .Y p d .... .p.... 4: d p : p p p d DINING ROOM INTERIOR WALLS KITCHEN/SUPPORT DINING & RESTROOM w 5 DINING ROOM PERIMETER JOINT 4 OVER WOOD OR METAL STUDS 3 FLOORS OVER CONCRETE 2 FLOORS OVER CONCRETE COVED TILE BASE DETAIL A5.2 NOT TO SCALE A5.2 NOT TO SCALE A5.2 NOT TO SCALE A5.2 NOT TO SCALE A5.2 NOT TO SCALE � ROOM FINISH SCHEDULE WALL TILE SCHEDULE FLOOR TILE SCHEDULE ARCHITECT OF RECORD: �D AP NO. ROOM NAME FLOOR BASE WALLS CEILING WALL MORTAR SETTING BED GROUT FLOOR BASE MORTAR SETTING BED GROUT i . L0 * U J W J Z U J W W H d C) O Z Z -i Z Z >O ;d U I < m * Q� 044171 4 F- of ZCL Z O Z L,,,i cr ? � � N Lij CL o v a w ¢ Q IT IS A VIOLATION OF THE _ uJ o w o r � 'd o o `� ¢ � � r�J V j `� i LAW FOR ANY PERSON, -� J o m ¢ o U o o o N UNLESS ACTING UNDER THE w ~ � o � o � � mww0° ~ ~ mNu 0° zmZ DIRECTION OFALICENSED m r J z w o 5 > > ~ ci M Q o ARCHITECT TO ALTER AN ITEM m � o � m o o z � � � � v0- w -� -' Utn w I z N - I < � a- >. ui>- 0- 0_ � � � w ¢ X o_ Xw z IN ANY WAY. U cy (n U H > -t > CCD U- � U U U a- N N cq � d 100 CUSTOMER SERVICE • • • . • • CERAMIC OR PORCELAIN WALL TILE TILE NOTE 4C LATEX-PORTLAND CEMENT THIN SET (MEDIUM BED) HIGH PERFORMANCE CEMENT GROUT QUARRY TILE (TILE NOTE 2) COVED QUARRY TILE MODIFIED-PORTLAND CEMENT THIN SET MORTAR (MEDIUM BED) CHEMICAL RESISTANT (TILE NOTE 7) x a = z 101 DINING • • • • • CERAMIC OR PORCELAIN WALL TILE (TILE NOTE 4B & 4C) LATEX-PORTLAND CEMENT THIN SET (MEDIUM BED) HIGH PERFORMANCE CEMENT GROUT PORCELAIN FLOOR TILE (TILE NOTE 3) NONE - WALL TILE LATEX-PORTLAND CEMENT THIN SET (MEDIUM BED) HIGH PERFORMANCE CEMENT GROUT w o 105 KITCHEN • • • • • • • • N/A - SEE ROOM FINISH SCHEDULE (GENERAL NOTE 5) QUARRY TILE (TILE NOTE 2) COVED QUARRY TILE MODIFIED-PORTLAND CEMENT THIN SET MORTAR (MEDIUM BED) CHEMICAL RESISTANT (TILE NOTE 7) o � .9 o z8q W a 000 v n H R U 0 U L. 0, o -° o a ym vu>ava o > o v -0 J aemv° v3 u0 0vc : ru v3:,o a m 0._ , QC U O p d N N M D w E O C 0 w .+ 0 t ° c Qt n N 0 0.0 ° y C 0,0++t -++ C ag L O'rt°-, ° y O C N m : V C++ fA O O_ O C mvo °'@Euc p 0 U'C O y 0 08 , rt+ 0 m O V C L 01 0 H c N ►U- 7 r+ w ° ° TILE NOTES GENERAL NOTES v V).2 la an-0. ` wNa•mvcN�° HARDWARE NOTES: ° D t" • d vuca� om 1. ALL EXIT DOORS SHALL BE KEYLESS IN THE DIRECTION OF EGRESS. r rn°'c - °'_0 1. REFERENCE: 2018 MCDONALD S PROJECT MANUAL - SECTION 09300 1. WHEN BUILDING TYPE IS A NON-COMBUSTIBLE CATEGORY, ALL PLYWOOD SHALL v_ o u 2 aci 2. THE OPENING FORCE OF ALL EXTERIOR PUSH/PULL DOORS SHALL NOT EXCEED 5 Ibs. -v °� -.2 >•>` BE FIRE RETARDANT TREATED. z 3. THE OPENING FORCE OF ALL INTERIOR PUSH/PULL DOORS SHALL NOT EXCEED 5 Ibs. 2. QUARRY TILE: ° o v' m 3 .0 4. PROVIDE PANIC HARDWARE FOR ALL EXTERIOR DOORS AS NOTED ON THE DOOR SCHEDULE 2. FRP PANELS: �2 c t w m o CL�° DAL-TILE DIABLO RED 6X6 ABRASIVE TILE WITH BLACK GROUT c °'*' c o 5. ALL DOOR HARDWARE SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE a. FRP OVER CEMENT BD BEHIND 3-COMP SINK TO HEIGHT OF BACK SPLASH ow 3 w c c ; � 6. DOOR HARDWARE LISTED BELOW IS FOR REFERENCE (FOR REPLACEMENT OR REPAIR) ONLY UNLESS NOTED OTHERWISE. ALT: "ASHEN GRAY" 6X6 ABRASIVE TILE WITH BLACK GROUT o ® � �; o 0 0 2 �� m c 7. NOT ALL HARDWARE LISTED BELOW MAY BE USED. SEE Al SERIES FOR DOOR TAGS & DOOR SCHEDULE ON THIS SHEET. b. FRP OVER CEMENT BD OVER EXTERIOR GRADE PLYWOOD (NOTE 5) AT MOP w �u S 0 0 3. FLOOR TILE: SINKS N a° ' m N" " a d2 rr " rr " " n w t c'3' O O.c d L MAIN & ACCENT: 6 x36 ,12 x24 OR 13 x20 (SIZE & SERIES MAY VARY). USE ONLY APPROVED 3. PROVIDE CEMENT BOARD BACKER OR EQUIVALENT AT ALL CERAMIC TILE a ~ a 3"' c w m TILE SERIES AND COLORS BY DALTILE, CROSSVILLE AND EUROWEST. VERIFY COLOR AND PATTERN LOCATIONS. PER INTERIOR DECOR DRAWINGS. Z 4. ALL FINISH SURFACES OF WALL AND CEILING MATERIALS SHALL BE CLASS B o N m w N v Lo A. MUST BE PER McDONALD'S USA, LLC: STANDARDS FOR INTERIOR FLOOR TILE AND APPROVED AND SHALL HAVE A FLAME SPREAD RATING OF 26 TO 75 AND A SMOKE o w N o N N TILE LIST. DENSITY OF 450 MAX. 3 Y 0 J Q w n ow rj " 5. DECORATIVE MATERIALS SHALL BE FLAME RETARDANT AND MEET THE CRITERIA D N EE _ ~ o 0 B. MUST BE NO LARGER THAN 6 x36 , 12 x24 OR 13 x20 . o o_ o\ U C. MUST MEET THE FOLLOWING: OF NFPA 701. z a Q 6. DECORATIVE MATERIAL SHALL NOT CONCEAL EXITS, EXIT LIGHTS, ALARM STATIC COEFFICIENT OF FRICTION (PER ASTM F1667-96) STATIONS, HOSE CABINETS, AND EXTINGUISHER LOCATIONS. LEVEL SURFACES: MINIMUM 0.50 DRY AND WET (McDONALD'S STANDARD) 7. VERIFY SS BACK SPLASH IS PRESENT AT ALL SINK LOCATIONS. N to DYNAMIC COEFFICIENT OF FRICTION (PER ANSI A137.1 2012) 8. SEE REFLECTED CEILING PLAN FOR HEIGHTS & LAYOUTS. LEVEL SURFACES: MINIMUM 0.5 DRY AND WET (McDONALD'S STANDARD) 9. PROVIDE 1/2" PLYWOOD BEHIND INTERIOR FINISH BOARD FOR ALL 4. TILE TRANSITION AND EDGE PROTECTION: WALL-MOUNTED MONITORS - VERIFY WITH DECOR DRAWINGS. A. TILE BASE (RESTROOM ONLY): SCHLUTER DILEX-AHK SERIES, BRUSHED STAINLESS STEEL. B. TILE EDGE PROTECTION (WALL TRANSITION): SCHLUTER-RONDEC-DB, SATIN ANODIZED ALUMINUM. C. TILE CORNER PROTECTION (OUTSIDE CORNER): SCHLUTER-RONDEC-AE, SATIN ANODIZED Q g Z N ALUMINUM. C� w Of D. SEE INTERIOR DECOR DRAWINGS FOR ALL LOCATIONS. 0 ' N BEFORE FINAL INSPECTION, REMOVE PROTECTIVE COVERINGS AND PERFORM FINAL CLEANING. � o w o a 5. TILE CLEANER: DETERDEK, BY FILA SURFACE CARE PRODUCTS - NO SUBSTITUTIONS ALLOWED. m g 0 CAN BE ORDERED BY EUROWEST, DALTILE, OR DIRECT FROM MANUFACTURER: FILA/DETEREK. O o cn co w POST INSTALLATION CLEANING REQUIRED ON ALL FLOOR TILE INSTALLTIONS PRIOR TO RESTAURANT LiJ z o Z TURN OVER. H-- a w w Lo ANY EXISTING FINISHES WHICH ARE TO REMAIN N m i APPLY CLEANER PER MANUFACTURER'S WRITTEN INSTRUCTIONS. DURING CONSTRUCTION BECOME DAMAGED, G.C. - REFERENCE: 2013 MCDONDALDS PROJECT MANUAL - SECTION 09300 TILING INTERIOR. TO REPLACE WITH MATCHING MATERIAL IN KIND. N W o w t o 6. GROUT COLOR AND MANUFACTURER AS INDICATED ON SHEET A1.0 AND INTERIOR DECOR DRAWINGS. 7. WATER-CLEANABLE, TILE-SETTING EPDXY (100% SOLIDS, INDUSTRIAL-GRADE) ALL SCHEDULES ON THIS SHEET ARE FOR REFERENCE ONLY. G.C. z IS TO REFER TO APPROVED DECOR PACKAGE FOR FINAL FINISHES. w N FINISH SCHEDULES & DETAILS NOTE: REMOVE EXISTING KITCHEN EQUIPMENT AND mVERIFY SCOPE OF WORK WITH ALL ASSOCIATED PIPING NOT BEING REUSED. PROJECT MANAGER BEFORE CAP EXISTING PIPING AIR TIGHT. BEGINNING DEMOLITION I � I � I ' o w V 1-7 0 O O 0 J LJ II _ SUPPORT FREEZER - - z - .1. W I L ENGINEER OF RECORD:LWOkIEWS I 0 cooLER JA' S orassl� P `� - o -- 1 1 0 G L� _ IT IS A VIOLATION OF THE LAW FOR ANY PERSON, \ - — — UNLESS ACTING UNDER THE DIRECTIOfJ OF A LICENSED / ARCHITECT, TO ALTER AN ITEM `., - IN ANY WAY. DINING 0 10 F� .: O r tD CREW EUJ r .. U RO OM =�' Ali -- OFFICE 100 - I P2 m $ 8 n O 0 1 DM ESTTIC WATER, WASTE, & VENT PIPING DEMO PLAN -- ` P1 CUSTOMER SCALE: 1 4 = 1 '-0" P2 SERVICE v v o 8 U I,ITI .HEP�I ; 105 c a a i U a O° v ° N 7a0 - 11) C.N ° oav O O O p C c p ) ,° 0-- o0p m a cl / 1 p v 3 cn o a N Q U N L p O O E cf) a n O C Ow- U--� p C Qt d ' N p 00 3 — p N p C° t_ 0 O N" O p C ' N N U 0) E p � a O ptn o c p C ° C px .4% ° ��LIi" O U 0 p O C N —__ _ - _J O -J~ ,C O p N OU C O U cn O U N E 2:, I _ p C U) D O 7 Vp p N O U C ! O v 0 a O p 0 3 ° 0 ° 0� o ® o ° a w p N C N O < N U 0 7 (71 O D U a a d 2 DOMESTIC WATER, WASTE, & VENT PIPING o N m N � � w O w I, m w 0 V) N o d P 1 .0 SCALE: 1 4' = 1 '-0" Z `r' D � J �' \ � "o Q w V J w w � a I N Q U N Ln 2 r z DRAWING NOTES KEYE NOTES Y U H Q 1 . ALL EXISTING PIPING LOCATIONS AND SIZES SHALL BE FIELD w VERIFIED PRIOR TO BEGINNING WORK. P1 RELOCATED KITCHEN EQUIPMENT. a 2. PIPING ROUTES ARE GENERAL AND MAY VARY DUE TO FIELD Q z_ tn CONDITIONS. COORDINATE ALL PIPE ROUTES WITH OTHER TRADES. P2 NEW KITCHEN EQUIPMENT. CD cl < w } z w z 3. ALL WATER DISTRIBUTION PIPING SHALL BE INSULATED. O C:) Q > _j w W o w o Q LL m w o uw o O o V) 00 W w °° _z Q OLn U Z fry F- a w w v N 'j � w w p N W w o w F o O w p 1 0 V) WATER, WASTE & VENT PIPING GENERAL MECHANICAL NOTES: 1 . ALL WORK PERFORMED SHALL BE IN ACCORDANCE WITH ALL LOCAL CODES AND ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. AIR DEVICE SCHEDULE KEYED NOTES DRAWING NOTES m 2. ALL DIMENSIONS, CLEARANCES AND TOLERANCES SHALL BE VERIFIED PRIOR TO TAG MANUFACTURER MODEL BORDER SIZE COLOR ACCESSORIES NOTES INSTALLATION. [E ALL SUPPLY AIR DIFFUSERS SHALL BE INSULATED TO PREVENT 1 . ALL NEW AND EXISTING DUCTWORK SHALL BE RUN BETWEEN OR 3. ALL MATERIALS, FIXTURES AND EQUIPMENT USED SHALL BE IN ACCORDANCE WITH S-2 TITUS OMNI LAY-IN 24x24 VARIES 1 ,2,3 1 ,2,3 CONDENSATION. THROUGH THE JOISTS UNLESS NOTED OTHERWISE. CONNECT TO PRICE SPD NEW OR RELOCATED DIFFUSERS AS REQUIRED. DUCTWORK McDONALD'S SPECIFICATIONS. SPECIFICATIONS ARE CONTAINED WITHIN THESE DESIGNATED WITH (B.J.) SHALL BE RUN BELOW THE JOISTS. DRAWINGS AND THE McDONALD'S PROJECT MANUAL. ANY RCONTRACTOR IN NEED ACCESSORIES: NOTES: OF A COPY OF THE: McDONALD'S PROJECT MANUAL SHALL CONTACT THE 1 . BACKPAN INSULATION 1 . SEE PLAN FOR NECK SIZES 2. DUCT SIZES SHOWN ARE INTERNAL FREE AREA DIMENSIONS McDONALD'S AREA CONSTRUCTION MANAGER. ANY VARIANCE FROM THE 2. BLANK-OFF PANEL AS SHOWN ON 2. AIR DEVICE FINISH C VARY: UNLESS NOTED OTHERWISE. McDONALD'S SPECIFICATIONS SHALL BE REVIEWED AND APPROVED BY THE DUCTWORK PLAN * KITCHEN, STORAGE, RESTROOMS - WHITE ENGINEER-OF-RECORD. 3. PLASTER FRAME MAY BE NECESSARY - * DINING ROOM, VESTIBULES - WHITE, BLACK OR 3. DIFFUSERS IN DINING ROOM ARE SPECIFIC TO THE DECOR PLAN COORDINATE WITH DECOR DRAWINGS PAINTABLE/PRIME COAT (COORDINATE FINAL SHOWN. DIFFERENT CEILING LAYOUTS MAY REQUIRE A DIFFERENT z 4. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ITS LISTING AND/OR COLOR WITH DECOR PLANS). DIFFUSER TYPES, QUANTITIES, LOCATIONS AND FINISHES/COLORS. THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3. ADDITIONAL ACCESSORIES AND/OR ALTERNATE DIFFUSERS MAY a_ BE REQUIRED. REFER TO DECOR DRAWINGS TO VERIFY. U 5. SEE COORDINATION SCHEDULE FOR ADDITIONAL SCOPE OF WORK. Li w 0 6. PRIOR TO BUILDING TURNOVER, A COMPLETE START-UP, TEST, ADJUST AND BALANCE SHALL BE PERFORMED ON ALL MECHANICAL SYSTEMS. THIS WORK SHALL BE PERFORMED BY A CERTIFIED TEST AND BALANCE CONTRACTOR. A CERTIFIED TEST AND BALANCE CONTRACTOR CAN BE FOUND BY VISITING: HTTP://WWW.A,gBCHQ.COM/DIRECTORY HTTP://WWW.NEBB.ORG/DiRECTORY.HTM HTTP://WWW.TABBCERTIFIED.ORC/SITE/CONTENT/CONTRACTORS/SEARCH 7. UPON COMPLETION OF THE PUNCHLIST, THE MECHANICAL CONTRACTOR AND TEST w AND BALANCE CONTRACTOR SHALL SUBMIT REDLINED OR AS-BUILT DRAWINGS Q ALONG WITH THE TI-ST AND BALANCE REPORT AND ALL EQUIPMENT OPERATION AND MAINTENANCE MANUALS TO THE McDONALDIS AREA CONSTRUCTION MANAGER. A MINIMUM OF TWO (2) COPIES SHALL BE PROVIDED, ONE (1) FOR REGIONAL w RECORDS AND ONE (1) FOR THE RESTAURANT. o ENGINEER OF RECORD: 8. ALL PENETRATIONS OF FIRE-RATED WALLS SHALL BE FIRESTOPPED WITH AN tJ ' NC - APPROVED AND LISTED FIRESTOPPING SYSTEM. l?r� rA VENTILATION SYSTEMS: q� t � 1 . ALL SHEET METAL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN sl ACCORDANCE WITH LOCAL CODES AND SMACNA STANDARDS. ' 2. ALL DUCTWORK DIMENSIONS ARE INTERNAL FREE AREA DIMENSIONS AND SIZED FOR ! 0.1" W.C. PER 100 FT. OF DUCT. °'' a 3. ALL SHEET METAL DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH / ` ' IT IS A VIOLATION OF THE SMACNA TABLES FOR 2" W.C. AND SHALL BE SUPPORTED WITH AN APPROVED < LAW FOR ANY PERSON, HANGER AT INTERVALS NOT EXCEEDING 10 FT. SUPPORT UNLESS ACTING UNDER THE 104 DIRECTION OF A LICENSED 4. ALL DUCT DROPS INTO THE BUILDING SHALL BE INSTALLED WITH FLEXIBLE FREEZEF' ARCHITECT, TO ALTER AN ITEM CONNECTIONS TO ISOLATE THE DUCTWORK SYSTEM FROM NOISE AND VIBRATION. IN ANY WAY. 111 FLEXIBLE CONNECTIONS SHALL BE TESTED IN ACCORDANCE WITH UL 181 AND LISTED AS CLASS 0 OR CLASS 1 . a Q. U � = d o 5. ALL DUCT DROPS INTO THE BUILDING SHALL BE OFFSET AS NECESSARY TO ALLOW CC) FOR THE CLEAR INSTALLATION OF THE EXTERNAL DUCTWORK INSULATION. 6. ALL DUCTWORK BRANCHES SHALL BE SUPPLIED WITH A VOLUME DAMPER FOR WOMEfd'S ° BALANCING. VOLUME DAMPER SHALL HAVE A 2" OFFSET TO ACCOMMODATE F0l EXTERNAL INSULATION. 7. TAKE-OFFS FROM RECTANGULAR TO ROUND DUCT SHALL BE DUCTMATE STRAIGHT-SIDED OR CENTER HIGH-EFFICIENCY TAKE-OFFS WITH A 2" DAMPER COOLER JA STAND-OFF TO ACCOMMODATE FOR EXTERNAL INSULATION. 0 CLCl. ';• .. 1 .O 8. ALL DUCTWORK JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS SHALL BE SEALED '...___.._.l o WITH WELDS, GASKETS, MASTICS (ADHESIVES), TAPES, ETC. ALL SEALANT ° 6g a �_-�o MATERIALS SHALL EE LISTED IN ACCORDANCE WITH UL 181A OR 181 B. m �'5 0 0 9. ALL SUPPLY AND RETURN SHEET METAL DUCTWORK LOCATED WITHIN THE CEILING U SPACE SHALL BE EXTERNALLY INSULATED. INSULATION SHALL BE 2" THICK DIfJING MICROLITE XG-100 BY JOHNS MANVILLE OR EQUAL. MFfJ ` 101 0 , o L L _ Q) C•N o 10. ALL SUPPLY AND RETURN SHEET METAL DUCTWORK LOCATED OUTSIDE OF THE ° cm) _ ° o o ° BUILDING SHALL BE INTERNALLY LINED WITH A 1 " THICK FIBERGLASS (MIN. R-4.2) ° L ° AND EXTERNALLY INSULATED WITH A 1Y2" THICK RIGID POLYSTYRENE, L'-- - J O ---- --. ---._....._. .._._._._.._. ..._....._._.. N a L a o 0 O N'° Q O POLYURETHANE OR POLYISOCYANURATE BOARD (MIN. R-7.5). INTERNAL (-PEWr Q) 3 ' E o m FIBERGLASS INSULATION SHALL BE LINATEX BY JOHNS MANVILLE OR EQUAL. p0,_,f,,l N D_ EXTERNAL RIGID BOARD INSULATION SHALL BE THERMAPINK BY OWENS CORNING OFFICE _._.._ _..__.___._._ -_F_x.__; -_________ - _ - a ° ° Q, L L U U 1 0 v (n EXIST. CFM o OR EQUAL. 1I 08 I 11 1 E o ° 11 . ALL EXPOSED SPIRAL DUCTWORK SHALL BE INTERNALLY INSULATED TO PREVENT o 0 3 ° °c L I ...___......._ - ._____ C -.-. _ ---.................. .. _._.._...__ ___ EXIST "� @ � ° _� ° CONDENSATION (MIN. R-4.3). INTERNAL INSULATION SHALL BE 1 " THICK .--...- o o o ° o r7 < - SPIRACOUSTIC PLUS BY JOHNS MANVILLE OR EQUAL. ._. ;_.... ., _; (TYP) N ° ° o E c O C U C ° U O 12. ALL DUCTWORK PENETRATIONS THROUGH FIRE-RATED WALLS, BARRIERS OR ( 1 C _ITTO .1ER N ° ° o o PARTITIONS SHALL 13E PROTECTED WITH A FIRE DAMPER. THE PERIMETER OF THE E SERVI :E o J c v L 2 FIRE DAMPER SHALT_ BE FIRESTOPPED WITH AN APPROVED AND LISTED RELOCATE ALL EXISTING ; _j _ FIRESTOPPING MATERIAL. = w Q °= ° o v ITCHEI DIFFUSERS AS REQUIRED TO !=. -----_.__._.__ _':.........._...... _.. 1 00 M1 ° ° 05 AVOID CONFLICTS WITH NEW 1; ° 13. ALL EXTERIOR SHEET METAL DUCTWORK SHALL BE EXTERNALLY WRAPPED WITH AN LIGHTING. ........_..._...... ....' (TYP.) ta- N o APPROVED WEATHERPROOFING MATERIAL TO PROTECT AGAINST WATER PENETRATION -- ° ° `- ! ° � a°u L TE AND CORROSION. SIDES AND TOP DF EXTERNAL WEATHERPROOFING SHALL BE I ° ° o N a ALUMAGUARD 60 MIL UV BARRIER BY POLYGUARD OR EQUAL. BOTTOM OF U C O (f7 ° EXTERNAL WEATHERPROOFING SHALL BE VAPORGUARD 5 MIL MEMBRANE BY -- ---- -- - -- - - a- POLYGUARD OR EQUAL. °. L� Cp 0 3 0 °p 0 W 14. ALL FLEXIBLE DUCTWORK, METALLIC AND NONMETALLIC, SHALL CONFORM TO THE Q N a o n (n � 0 ° FOLLOWING: E� L - o o� v t A. 2" THICK INSULATION (R-6.0) ( ° o L o L � a3w c... cn.� w B. INTEGRAL VAPOR BARRIER C. LISTED AND LABELED UL 181 , CLASS 0 OR CLASS 1 D. INSTALLED IN ACCORDANCE WITH: ~ N i s < N m ul WIC m O 0 N N d i. SMACNA STANDARDS, ii. AIR DIFFUSION COUNCIL INSTALLATION GUIDELINES, AND/OR I Li - co o } ` W � _J w -� w d I MANUFACTURER'S INSTALLATION INSTRUCTIONS �' Q c' U oQ m o � vim 14. FLEXIBLE DUCTWORK SHALL NOT PENETRATE WALLS. SHEET METAL DUCTWORK IS cf) (3 REQUIRED AT ALL FIRE-RATED AND DRAFTSTOP WALL PENETRATIONS. 15. ALL COVERINGS, LININGS AND ADHESIVES (TAPES, ETC.) SHALL HAVE A `n FLAME-SPREAD INDEX NOT GREATER THAN 25 AND A SMOKE-DEVELOPED INDEX 0) NOT GREATER THAN 50. Z 16. DUCT-MOUNTED SMOKE DETECTORS SHALL BE INSTALLED IN SYSTEMS WITH DESIGN Y U CAPACITY GREATER THAN 2,000 CFM. SEE MECHANICAL DRAWINGS FOR LOCATIONS i OF SMOKE DETECTORS. DUCT-MOUNTED SMOKE DETECTORS ARE NOT REQUIRED G WHEN THE BUILDING IS PROTECTED THROUGHOUT BY AREA SMOKE DETECTORS CONNECTED TO A FIRE ALARM SYSTEM WHERE THE FIRE ALARM SYSTEM IS w DESIGNED TO SHUT DOWN THE ROOFTOP UNITS. Q z � O 17. ALL SUPPLY AIR DIFFUSERS SHALL BE INSULATED TO PREVENT CONDENSATION. z- z Ld w z w z 18. ALL AIR DEVICES LOCATED IN DRYWALL CEILINGS SHALL BE SUPPLIED WITH AN - O O J INTEGRAL VOLUME DAMPER ACCESSIBLE FROM THE AIR DEVICE FACE TO FACILITATE BALANCING. 0 = m o 1� w t- a 19. ALL OUTDOOR AIR INTAKES SHALL BE LOCATED A MINIMUM OF 10 FT. �- z w w o HORIZONTALLY FROM ANY SOURCE CIF CONTAMINATION SUCH AS EXHAUST FANS, O C� a o co PLUMBING VENTS, WATER HEATER FLUES, ETC. WHERE A CONTAMINANT SOURCE IS 1 MECHANICAL CEILING PLAN z _o � z Ln LOCATED WITHIN 10 FT. OF AN INTAKE, THE INTAKE OPENING SHALL BE LOCATED A MINIMUM OF 2 FT. BELOW THE CONTAMINANT SOURCE. M .O SCALE: 1/4" = 1 '-0" F- ~ w `� d w m N Ld U aa- o O X cn o x w l N W o c> v~-i o 20. ALL ROOFTOP CONDENSING UNITS THAT DISCHARGE HORIZONTALLY SHALL BE ORIENTED SUCH THAT THE DISCHARGE DOES NOT BLOW IN THE DIRECTION OF AN OUTDOOR AIR INTAKE.MK m 1 0 w MECHANICAL CEILING PLAN ELECTRICAL SPECIFICATIONS AND GENERAL NOTES: LIGHTING: I � m 1. THE ELECTRICAL CONTRACTOR (E.C.) SHALL PROVIDE ALL LABOR AND MATERIALS NECESSARY FOR 28. ALL NEW CIRCUIT BREAKERS FOR EXISTING PANELBOARDS AND DISTRIBUTION PANELBOARDS SHALL 46. CONTRACTOR SHALL PROVIDE ALL NECESSARY PROPERLY SIZED WALL OR MILLWORK MOUNTED L1. COORDINATE THE LOCATION OF JUNCTION BOX (IN THE WALL) WITH THE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM/INSTALLATION. MATCH EXISTING BUILDING PANELBOARD MANUFACTURER AND CIRCUIT BREAKER TYPE ALL CIRCUIT BOXES, RINGS, SUPPORTS, AND DEVICES AS REQUIRED VIA COORDINATION WITH ARCHITECTURAL OPENING IN TRELLIS (FOR THE LIGHT FIXTURE WIRES). THE LOCATION BREAKERS SHALL BE BOLT ON TYPE. AIC RATING OF NEW CIRCUIT BREAKER SHALL MATCH AIC WALL SECTIONS, AND MILLWORK DETAILS. OF THE JUNCTION BOX AND THE OPENING IN THE TRELLIS SHALL BE 2, MATERIALS AND INSTALLATION SHALL COMPLY WITH ALL CODES, LAWS, AND ORDINANCES OF RATING OF PANELBOARD IN WHICH IT IS INSTALLED. WHERE SERIES RATED TYPE CIRCUIT BREAKERS ALIGNED FOR THE LIGHT FIXTURE TO BE INSTALLED PROPERLY. FEDERAL, STATE, AND LOCAL GOVERNING BODIES HAVING JURISDICTION. ARE USED, NEW CIRCUIT BREAKERS SHALL BE INSTALLED SO AS TO MAINTAIN THE UL SERIES 47. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THESE DRAWINGS. WHERE MORE COORDINATE INSTALLATION OF JUNCTION BOX AND ANY NECESSARY RATING OF THE ENTIRE SYSTEM. THE CONTRACTOR SHALL PROVIDE A NEW TYPEWRITTEN PANEL STRINGENT REQUIREMENTS THAN THOSE DESCRIBED HEREIN OR AS SET FORTH UNDER CODES, OPENINGS IN TRELLIS WITH GC AND AREA CONSTRUCTION MANAGER. 3, ALL MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L.,ETL, CSA, OR DIRECTORY FOR EACH PANEL CHANGED AT THE COMPLETION OF THE PROJECT. EACH CIRCUIT LAWS, AND ORDINANCES OF FEDERAL, STATE, AND LOCAL GOVERNING BODIES HAVING JURISDICTION, SEE LIGHT FIXTURE INSTALLATION INSTRUCTIONS FOR REQUIREMENTS ANOTHER RECOGNIZED TESTING LABORATORY. BREAKER SHALL BE LABELED TO IDENTIFY LOAD TYPE AND LOCATION THOSE GREATER REQUIREMENTS SHALL BE ADHERED TO. REGARDING MOUNTING BRACKETS FOR USE IN C-CHANNEL TRELLISES. COORDINATE LOCATION WITH TRELLIS MANUFACTURER. 4. THE CONTRACTOR SHALL SECURE AND PAS' FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND 29. THE CONTRACTOR SHALL VERIFY THE CEILING CONSTRUCTION TYPE WITH ARCHITECTURAL DETAILS 48. ALL NEW EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE PROVIDED WITH AN INTEGRAL LICENSES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL ELECTRICAL WORK. BEFORE ORDERING LIGHTING FIXTURES IN ORDER TO CONFIRM PROPER MOUNTING. EMERGENCY BACKUP BALLAST TO ILLUMINATE THE FIXTURES IN THE EVENT OF A POWER FAILURE. L2. EC SHALL COORDINATE LOCATIONS OF ALL LIGHT FIXTURES IN DINING ALL COMPONENTS SHALL BE IN COMPLIANCE WITH NFPA 101 AND NFPA 70 SECTION 700. AREA WITH FINAL SEATING AND DECOR PLANS. 5. THE CONTRACTOR SHALL PREPARE AND SJBMIT TO GOVERNMENTAL AGENCIES, UTILITY COMPANIES, 30. EACH SWITCH, LIGHT, RECEPTACLE, OR OTHER MISCELLANEOUS DEVICE SHALL BE PROVIDED WITH BALLAST BATTERY SHALL MAINTAIN 87.5% OF THE NOMINAL BATTERY VOLATAGE AFTER 1.5 HOURS L3. IF PC-POS CASH REGISTER SYSTEM IS INSTALLED, EC SHALL RELOCATE AND LOCAL CODE OFFICIALS, SHOP DRAWINGS AND/OR INSTALLATION DETAILS WHICH ARE A GALVANIZED OR SHERARDIZED PRESSED STEEL OUTLET BOX OF THE KNOCKOUT TYPE, OF NOT TO COMPLY WITH NEC SECTION 700 AND UL 924. FIXTURES ABOVE FRONT COUNTER TO AVOID GLARE ON THE CASH 00 REQUIRED BY THESE AGENCIES FOR THEIR APPROVAL. LESS THAN NUMBER 14 U.S. GAUGE STEEL. CONDUITS SHALL BE FASTENED WITH LOCKNUTS AND REGISTER SCREENS. EC SHALL INSTALL CABLE WHIP TO FIXTURES SO BUSHINGS AND ALL UNUSED KNOCKOUTS SHALL BE LEFT SEALED. THERE SHALL BE SUFFICIENT a- THAT FIXTURE MAY BE RELOCATED FOUR FEET WITHOUT 6. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT, ENGINEER, AND PROJECT MANAGER IN WRITING ROOM FOR WIRES AND BUSHINGS AND DEEP BOXES SHALL BE INSTALLED WHERE REQUIRED. 49. IDENTIFICATION OF ELECTRICAL ITEMS DISCONNECTING CABLE WHIP. v OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF BOXES SHALL BE SECURELY AND ADEQUATELY SUPPORTED. u� LAWS, ORDINANCES, RULES, OR REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. A. PROVIDE PERMANENT IDENTIFICATION MARKING AND NAMEPATES FOR ALL CONDUCTORS L4. THE USE OF "MC" CABLE IN LENGTHS OF 6 FEET OR LESS (WHERE Li 31. NOT USED AND EACH ITEM OF ELECTRICAL APPARATUS AND ASSOCIATED CONTROLLED EQUIPMENT, WITH PERMITTED BY LOCAL CODES) SHALL BE ALLOWED FOR WIRING TO ALL IDENTIFICATION MARKINGS 7. THE CONTRACTOR SHALL PREPARE AND SJBMIT TO THE FIRE PREVENTION BUREAU ALL THE SAME INSCRIPTIONS AS SHOWN ON THE DRAWINGS. INTERIOR LIGHTING FIXTURES. "ROMEX" OR "BX" SHALL NOT BE USED. DOCUMENTS, INCLUDING DRAWINGS AND SJBMITTALS, REQUIRED TO OBTAIN APPROVAL OF THE 32. IN SUSPENDED CEILINGS, SUPPORT CONDUITS AND JUNCTION BOXES DIRECTLY FROM THE SHALL BE CLEARLY AND NEATLY APPLIED. EMERGENCY LIGHTING, LIFE SAFETY, AND EXIT SIGN SYSTEM(S) FOR TYPES AND LOCATIONS. A STRUCTURAL SYSTEM, DECK OR FRAMING PROVIDED FOR THAT PURPOSE. LIGHTING BRANCH L5. EC SHALL VERIFY THAT NOT MORE THAN 3% VOLTAGE DROP EXISTS COPY OF THE APPROVED DRAWINGS SHALL BE PROVIDED TO THE ARCHITECT AND ENGINEER PRIOR CIRCUIT CONDUITS SHALL NOT BE CLIPPED TO THE CEILING SUPPORT WIRES OR SPLINE UNLESS B. APPLY ENGRAVED PLASTIC LAMINATE NAMEPLATES WITH NCN-CORRODING TYPE SCREW FROM THE LIGHTING PANEL TO ANY EXTERIOR LIGHTING FIXTURE OR TO THE START OF CONSTRUCTION. THE CEILING SYSTEM HAS BEEN SPECIFICALLY DESIGNED FOR THAT PURPOSE AND APPROVAL HAS FASTENERS OR RIVETS TO ALL MOTOR STARTERS, DISCONNECT SWITCHES, RELAYS, REMOTE SIGNAGE DRIVER. BEEN GRANTED BY THE ARCHITECT AND THE ENGINEER. CONTROL PANELS, PUSH BUTTON STATIONS, PANELBOARDS, SWITCHBOARDS, TRANSFORMERS, AND OTHER ELECTRICAL APPARATUS. NAMEPLATES SHALL BE WHITE WITH BLACK CORE, L6. WHERE MCDONALD'S RESTAURANT HAS A PLAYPLACE, THE EC SHALL 8. ALL NEW ELECTRICAL WORK OR MODIFICATIONS TO EXISTING ELECTRICAL DISTRIBUTION PANELS, 33. E.C. SHALL PROVIDE "3M" FIRESEAL SYSTEMS FOR ALL CORES AND RACEWAY PENETRATIONS IN 1-1/4" X 3" MINIMUM WITH 3/16" HIGH LETTERING. THE NAMEPLATE SHALL IDENTIFY: COORDINATE EXACT LOCATION OF PLAYPLACE LIGHTING WITH CONSTRUCTION IO METERS, ETC. SHALL BE INSTALLED O INDICATED ON THE ELECTRICAL FIRE RATED WALLS AND PARTITIONS. FIRE RATE WALL AND CEILING PENETRATIONS, ETC. USING -NAME OF DEVICE OR PLAYPLACE TOY VENDOR FOR MAXIMUM ILLUMINATION AND SAFETY PER w CONSTRUCTION DOCUMENTS. E.C. SHALL SUBMIT SHOP DRAWINGS OF ALL EQUIPMENT TO BE INSTALLED INDICATING FLOOR PLAN LAYOUT, ELEVATIONS, AND ALL DIMENSIONS FOR APPROVAL OF "CP-25" CAULK, "303" PUTTY AND/OR "FLAMESEAL" PUTTY AS PER MANUFACTURER'S -LOAD THE DEVICE IS SERVING THE FINAL LOCATION OF THE PLAYPLACE TOY. LIGHTING FIXTURES I Q THE ENGINEER PRIOR TO INSTALLATION. CODE REQUIRED CLEARANCES IN FRONT OF ALL INSTRUCTIONS TO MAINTAIN EXISTING AND NEW FIRE RATINGS. VERIFY FIRE RATING CONDITIONS SHALL NOT BE MOUNTED TO THE TOY OR ANY PART OF THE TOY o ELECTRICAL EQUIPM-NT SHALL BE MAINTAINED AT ALL TIMES. AND LOCATIONS PRIOR TO FINAL BIDS. ALL OPEN SLEEVE PENETRATIONS SHALL BE FIRESEALED C. PROVIDE A TYPEWRITTEN DIRECTORY OF CIRCUITS IN LIGHTING AND POWER PANELS AND STRUCTURE. INSIDE AND OUTSIDE BY E.C. AFTER ALL CABLING IS COMPLETELY INSTALLED. SEALING METHODS PROVIDE PANEL IDENTIFICATION IN BLACK ALKYD PAINT STENCILED INSCRIPTIONS ON THE 9. THE CONTRACTOR SHALL INCLUDE IN BID AN ALLOWANCE FOR THE FOLLOWING ADDITIONAL LIFE SHALL BE PROVIDED BY E.C. AND SHALL BE SUBJECT TO THE APPROVAL OF THE CABLING INSIDE OF THE DOOR, DIRECTLY ABOVE THE CENTERLINE OF THE DIRECTORY FRAME, OR ON I w SAFETY DEVICES, INCLUDING INSTALLATION AND ALL CONDUIT AND WIRE, FOR ADDITIONAL DEVICES CONTRACTOR. THE VERTICAL AND HORIZONTAL CENTERLINE OF DOORS WITHOUT DIRECTORY FRAMES. m AS MAY BE REQUIRED BY THE REVIEW OF THE AUTHORITY HAVING JURISDICTION. 34. NOT USED D. PROVIDE ON DEVICE PLATES FOR LOCAL TOGGLE SWITCHES, TOGGLE SWITCH MANUAL «�''"" ""' �• (2) EXIT SIGN FIXTURESt L t� STARTERS, PILOT LIGHTS AND OTHER ELECTRICAL ITEMS, WHOSE FUNCTION IS NOT READILY (2) EMERGENCY LIGHTING FIXTURES 35. NOT USED APPARENT, ENGRAVED SUITABLE INSCRIPTIONS OR PLASTIC LAMINATE NAMEPLATES DESCRIBING THE EQUIPMENT CONTROLLED OR INDICATED. CONTRACTOR SHALL PROVIDE A UNIT PRICE FOR EACH FOR QUANTITY ADJUSTMENT. 36. NUMBERED CIRCUITS SHOWN ON PLAN ARE FOR THE CONVEYANCE OF DESIGN INTENT ONLY. ACTUAL FIELD CONDITIONS WILL AFFECT CIRCUITRY. INDICATE THE ACTUAL CIRCUIT NUMBERS E. EMBOSSED SELF-ADHERING PLASTIC TAPE LABELS WILL NOT BE ACCEPTED. 10. THE CONTRACTOR SHALL INCLUDE IN BID ELECTRICAL UNIT PRICES (EUP) TO PROVIDE ADDITIONAL ; �J LIFE SAFETY DEVICES WITHIN FINISHED CEILING SYSTEMS, INCLUDING ALL CONDUIT AND WIRE, FOR INSTALLED ON THE "AS-BUILT" DRAWINGS. {, s,;,_e,...• c 50. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL EXISTING OR NEW NON-ACCESSIBLE SYSTEM EACH TYPE OF DEV CE AS SCHEDULED IN NOTE NUMBER 9. THE UNIT PRICE SHALL INCLUDE ALL DEVICES, PULLBOXES, AND EQUIPMENT, ETC. FOR RELOCATION TO ACCESSIBLE CEILING AREAS. E.C. c? GENERAL CONTRACTDR ASSOCIATED COSTS TO INSTALL DEVICES WITHIN INSTALLED CEILING 37. BUILDING STANDARDS of s.S��t A. ALL NEW CONDUIT RACEWAYS AND BOXES FOR ALL SYSTEMS SHALL BE INSTALLED SHALL INCLUDE ALL COMPLETE COSTS FOR RELOCATION AND VERIFY SUCH CONDITIONS WITH `'" ,,.. SYSTEMS. TIGHT-UP TO THE BOTTOM OF THE STRUCTURAL BEAMS WHERE REQUIRED AND PROPERLY ARCHITECTURAL CEILING PLANS PRIOR TO FINAL BIDS. 1 1/7/23 SUPPORTED FROM STRUCTURAL MEMBERS. IT IS A VIOLATION OF THE 11. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, MAKE A SCHEDULED 51. EXISTING CONDITIONS OF ALL EXISTING BUILDING EQUIPMENT, DEVICES, FIXTURES, AND SYSTEMS LAW FOR ANY PERSON, ARRANGEMENT WITH THE PROJECT MANAGER TO VISIT THE SITE, AND THOROUGHLY BECOME B. ALL NEW CONDUIT RUNS SHALL BE INSTALLED ABOVE AND OVER THE TOP OF ALL NEW THAT REQUIRE REWIRING, REUSE, RELOCATION, OR REFURBISHING AS PER DRAWINGS AND UNLESS ACTING UNDER THE FAMILIAR WITH THE BUILDING STANDARDS AND LOCAL CONDITIONS RELATING TO THE WORK. AND/OR EXISTING DUCTWORK, PIPING, CONDUITS, PULLBOXES, ETC. E.C. SHALL PROVIDE ALL SPECIFICATIONS SHALL BE FIELD VERIFIED BY THE E.C. PRIOR TO COMMENCEMENT OF ANY WORK DIRECTION OF A LICENSED FAILURE TO DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE CONTRACT. / ARCHITECT, TO ALTER AN ITEM NECESSARY ACCESSIBLE PULLBOXES. CONDUIT BENDS SHALL NOT EXCEED CODE TO BE COMPLETELY OPERATIONAL. E.C. SHALL SUBMIT A WRITTEN STATEMENT AND ITEMIZED IN ANY WAY, REQUIREMENTS WITHIN A SINGLE RUN. E.C. SHALL PROVIDE ALL PULLBOXES AS REQUIRED. LISTING OF ALL EXISTING CONDITIONS OF THE FOLLOWING, ALTHOUGH NOT LIMITED TO THOSE 12. THE CONTRACTOR ..HALL PROVIDE TEMPORARY POWER AND WIRING FOR THE PERFORMANCE OF LISTED: ALL TRADES, FOR THE ENTIRE PERIOD OF CONSTRUCTION AND SHALL REMOVE ALL TEMPORARY a- u = Z WIRING AT THE COMPLETION OF CONSTRUCTION. ALL COSTS FOR ESTABLISHING AND REMOVING C. NEW CONDUIT RUNS OR PULLBOXES SHALL NOT BE INSTALLED LESS THAN 2 INCHES A. HVAC EQUIPMENT ABOVE RECESSED LIGHTING FIXTURES UNLESS APPROVED BY THE ENGINEER. f Q N TEMPORARY POWER SHALL BE INCLUDED IN BID. B. EXIT SIGNS AND EMERGENCY LIGHTING FIXTURES _ 0 o D. NEW CONDUIT RUNS OR PULLBOXES SHALL NOT BLOCK OR PREVENT FULL AND C. LIFE SAFETY/FIRE ALARM SYSTEM DEVICES 13. THE EXISTING POWER, SIGNAL, AND COMMUNICATIONS SYSTEMS ARE TO REMAIN IN SERVICE TO COMPLETE ACCESS AND OPERATION OF NEW OR EXISTING HVAC EQUIPMENT, ACCESS DOORS, D. LIGHTING AND RECEPTACLE DEVICES. ...••y PROVIDE FOR THE OWNER'S EXISTING FUNCTIONS. SHOULD IT BECOME NECESSARY TO SHUT-DOWN PIPING VALVES, JUNCTION BOXES, DUCT HEATERS, MAIN SUPPLY AND RETURN AIR DUCTS, ANY SYSTEM OR PORTION OF A SYSTEM, APPROVAL IN WRITING MUST BE OBTAINED FROM THE PULLBOXES, CLEANOUTS, ETC. THE WRITTEN STATEMENT SHALL BE SUBMITTED TO THE PROJECT MANAGER, ARCHITECT, AND $ .a o PROJECT MANAGER AND SHALL BE ONLY FOR THE PERIOD AND TIME AGREED UPON. THE BID IS ENGINEER PRIOR TO WORK. IN THE EVENT THAT THE CONTRACTOR COMMENCES WORK WITHOUT TO INCLUDE THE COST OF ANY TEMPORARY WIRING AND PREMIUM TIME REQUIRED FOR THE E. NEW CONDUIT AND PULLBOXES TO BE INSTALLED BELOW NEW OR EXISTING DUCTWORK SUBMITTAL, THE CONTRACTOR SHALL ASSUME ALL RESPONSIBILIT,' AND COST TO MAINTAIN THE SHUTDOWN. SHALL BE MOUNTED TIGHT UP TO BOTTOM OF DUCT WITH 90 DEGREE BENDS UP SIDEWALL ABOVE IN GOOD WORKING ORDER AND CONDITION. ' 14. ALL MATERIALS AND EQUIPMENT SHALL BE ERECTED, INSTALLED, TOOLED, CONNECTED, CLEANED, OF DUCT TO MEET REQUIREMENTS OF LETTER C ABOVE. SUPPORTS SHALL NOT PENETRATE DUCTWORK, AND SHALL BE INDEPENDENT OF ALL DUCTWORK SUPPORTS. DIRECT CONTACT 52. E.C. SHALL REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ALL ELECTRICAL AND ADJUSTED, TESTED, CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH THE COMMUNICATIONS OUTLETS. ELECTRICAL ENGINEERING DRAWINGS SHALL BE USED FOR CIRCUITING ? MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. OF CONDUIT RACEWAY SYSTEMS WITH DUCTWORK OR PIPING SHALL BE PROVIDED WITH INFORMATION ONLY. VIBRATION SEPARATION METHOD APPROVED BY THE ENGINEER. m 15. ALL CUTTING, DRILLING, AND PATCHING OF MASONRY, DRYWALL, CONCRETE, STEEL, OR IRON WORK F. NEW CONDUIT AND BOXES TO BE INSTALLED WITHIN ALL EXISTING FINISHED BUILDING 53. E.C. SHALL REFER TO MECHANICAL AND PLUMBING ENGINEERING DRAWINGS FOR EXACT LOCATIONS 8 BELONGING TO THE BUILDING SHALL BE DONE BY THIS CONTRACTOR IN ORDER THAT WORK MAY OF ALL MECHANICAL AND PLUMBING EQUIPMENT. .z DRYWALL, FURRED BUILDING WALLS, PARTITIONS, AND COLUMNS SHALL BE INSTALLED WITH BE PROPERLY INSTALLED. UNDER NO CONDITIONS MAY STRUCTURAL WORK BE CUT. EXCEPT AT o g EMT AND FLEXIBLE RACEWAYS NOT MORE THAN 6'-0" LONG. ELECTRICAL CONTRACTOR a THE DIRECTION OF THE ARCHITECT/ENGINEER OR THEIR REPRESENTATIVE. SHALL INCLUDE ALL COSTS FOR DRYWALL ACCESS, CUTTING, PATCHING, PAINTING, ETC. IN BIDS FOR SUCH CONDITIONS. FIELD VERIFY ALL LOCATIONS ON SITE PRIOR TO FINAL BIDS. 16. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, CUTS, DIAGRAMS, EXCEPTIONS DURING BIDS SHALL BE SUBMITTED IN WRITING. ° T -E o-a AND OTHER SUCH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE u o a_ U) N a o a p O ° ° EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS (FOR EXAMPLE ALL LIGHTING FIXTURES). G. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BE HELD RESPONSIBLE TO o C,L �, L o PARTIAL SUBMITTALS WILL NOT BE REVIEWED. HAVE EXAMINED THE CONSTRUCTION SITE WITH RESPECT TO CONSTRUCTION DRAWINGS, ° a Q) v° a ACTUAL FIELD CONDITIONS, DOOR FRAME HEIGHTS, PIPING OBSTRUCTIONS, DUCTWORK v ° ` o E 0 ° 17. SUBMIT FOUR (4) COPIES OF THE FOLLOWING SHOP DRAWINGS FOR REVIEW: HEIGHTS AND LEVELS, FLOOR LEVELS, CEILING HEIGHTS, ETC. PRIOR TO FINAL BIDS. =0 ° -°o 6 o A. LIGHTING FIXTURES AND LAMPS ° -o o ,� 3 D•- `O rn B. WIRING DEVICES H. ALL NEW BUILDING STANDARD EQUIPMENT, DEVICES, AND MATERIALS SHALL BE EQUAL TO 0 " Q Nco " Q C. LOW VOLTAGE RELAYS AND SWITCHES OR GREATER IN QUALITY TO EXISTING APPROVED BUILDING STANDARD MATERIALS PRESENTLY Q ° °, - � u Q) ( � ovQ) D. DIMMERS AND CONTROLS INSTALLED IN BUILDING. EQUIPMENT, DEVICES AND MATERIALS SHALL BE SUBJECT TO THE E 'o APPROVAL OF THE ARCHITECT, PROJECT MANAGER, AND THE ENGINEER. o a , o °'o a 18. CONTRACTOR SHALL PROVIDE "AS-BUILT' DOCUMENTATION AND HARD COPY REPRODUCIBLE N o ° 0.3 0 ° L DRAWINGS AT THE COMPLETION OF THE PROJECT AND SUBMIT TO THE ARCHITECT AND THE I. ALL EMERGENCY AND EXIT SIGN JUNCTION BOXES SHALL BE PAINTED RED. PANEL TAG - L o ENGINEER. AS-BUILT DRAWINGS SHALL INDICATE EXACT CIRCUIT NUMBERS, LOCATIONS OF ALL AND CIRCUIT NUMBER FOR ALL WIRING WITHIN JUNCTION BOX BE INDICATED ON ,^ i'0 ° o o ° DEVICES, CEILING FIXTURES, AND RACEWAY FOR LIGHTING, TELECOMMUNICATIONS AND POWER COVER. °v/ � E N o DISTRIBUTION SYSTEMS AS INSTALLED. o a °'o ° ° J. ALL JUNCTION BOXES SERVING LIGHTING AND POWER SHALL HAVE CIRCUIT NUMBERS AND LIGHTING SCHEDULE NOTES: KEY - 19. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW AND OF COMMERCIAL GRADE PANEL TAGS FOR ALL WIRING WITHIN JUNCTION BOX SHALL BE INDICATED ON COVERS. LS 1 . ORDER LED EXIT SIGNS WITH LETTER COLORS THAT COMPLY WITH LIGHTING FIXTURES SHOWN HALF SHADED SHALL o o UNLESS SPECIFICALLY INDICATED AS EXISTING TO BE REUSED ON DRAWINGS. LOCAL CODES. (®� BE WIRED TO AN EMERGENCY INVERTER AND Q H 38. A NEW PANELBOARD COPPER GROUND BUS SHALL BE INSTALLED FOR EQUIPMENT GROUNDING DENOTES CIRCUITED AS A NIGHT LIGHT. SEE NOTE EL3 ON ,L_ w cn o o c o 20. EXCEPT AS NOTED OTHERWISE, ALL WORK REQUIRED FOR THE ELECTRICAL INSTALLATION AS REQUIREMENTS FOR ALL PANELBOARDS LACKING A GROUND BUS. - FOR RED LETTERS USE #EVE-U-R (UNIVERSAL), FIXTURE TYPE F2 ��E2.0 FOR EMERGENCY LIGHTING INVERTER a o o q' � Ln FOR GREEN LETTERS USE EVE-U-G UNIVERSAL , OR 1 REQUIREMENTS. COORDINATE LOCATION WITH O cn a o t SHOWN ON DRAWINGS SHALL INCLUDE ALL LABOR, INSTALLATION METHODS, EQUIPMENT, AND # ) DENOTES CIRCUIT DECOR. Q -0 ° 0 L MATERIALS AND SHALL BE IN STRICT COMPLIANCE WITH ALL BUILDING STANDARDS. 39. PERFORM ALL WORK OF A DEMOLITION NATURE THAT MAY BE REQUIRED OR NECESSARY FOR THE IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE: 0 a� Q m L T FULL AND COMPLETE EXECUTION OF THE WORK, WHETHER EXPLICITLY SHOWN AND/OR SPECIFIED LED SIGN WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE & NUMBER LIGHTING FIXTURES SHOWN WITH A SLASH SHALL o ° ° N �o a ° 21. PROVIDE A COMPLE--E METAL RACEWAY SYSTEM, FITTINGS AND ENCLOSURES FOR ALL ELECTRICAL OR NOT. EXACT EXTENT OF DEMOLITION WILL NOT BE FULLY INDICATED BY DRAWINGS. DETERMINE DIRECTIONAL ARROWS AS REQUIRED BY THE LOCAL AUTHORITIES. BE WIRED TO AN EMERGENCY INVERTER AND �� LE ° m 0 WIRING SYSTEMS TO BE INSTALLED FOR THE PROJECT. SYSTEMS SHALL INCLUDE, BUT NOT BE THE NATURE AND EXTENT OF DEMOLITION THAT WILL BE NECESSARY BY COMPARING THE DENOTES CIRCUITED AS SWITCHED EMERGENCY FIXTURES SO o o LIMITED TO POWER, COMMUNICATIONS, SECURITY, PAGING, TEMPERATURE CONTROL AND CONTROLS. CONTRACT DOCUMENTS WITH ARCHITECTURAL AND DEMOLITION DRAWINGS TO EXISTING CONDITIONS. FIXTURE TYPE F2 THE FIXTURE IS CONTROLLED VIA TIMECLOCK BUT `` ° ° 3 °o ° 0 LS2. ALL INTERIOR LIGHT FIXTURES SHALL BE 120 VOLT UNLESS NOTED ELECTRICAL EQUIPMENT WHICH WILL NOT BE REUSED SHALL BE TURNED OVER TO THE OWNER OR DENOTES CIRCUIT 1 TURNS ON UPON LOSS OF POWER. SEE NOTE EL3 ° - a).t (n o 22. NOT USED. REMOVED FROM THE PREMISES AS DETERMINED BY THE PROJECT MANAGER. OTHERWISE. L ON E2.0 FOR EMERGENCY LIGHTING INVERTER Q U) a o co•> NUMBER REQUIREMENTS. COORDINATE LOCATION WITH w o " LS3. LIGHTING FIXTURES HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM DECOR. o ° o L 23. MINIMUM CONDUIT SIZE SHALL BE 1/2 INCH FOR GENERAL LIGHTING AND POWER CIRCUITRY 40. ANY EXISTING ELECTRICAL MATERIAL AND EQUIPMENT WHICH INTERFERES WITH THE NEW ADDITION � `� � 3 w `" `n" UNLESS OTHERWISE INDICATED AND/OR REQUIRED BY CODE. OR THE REMOVAL OF EXISTING WALLS SHALL BE REMOVED OR RELOCATED BY THE CONTRACTOR. ENERGY CONSERVATION WHILE MAINTAINING ADEQUATE LEVEL OF VERIFY REMOVAL AND NEW LOCATION OF EQUIPMENT WITH THE PROJECT MANAGER AND THE ILLUMINATION. SPECIFICATIONS SHALL BE STRICTLY FOLLOWED. ANY 24. FLEXIBLE CONDUIT CONNECTIONS TO RECESSED LIGHTING FIXTURES SHALL BE MADE WITH FLEXIBLE ARCHITECT/ENGINEER PRIOR TO WORK. DEVIATION FROM THE SPECIFICATIONS SHALL BE APPROVED IN WRITING m o o m o u o w Ln STEEL CONDUIT, 1/2_ INCH MINIMUM, INCLUDING AN INSULATED COPPER GREEN EQUIPMENT BY McDONALD'S CORPORATION. z c� `�' o \ C) � GROUNDING CONDUCTOR OR SHALL BE MADE WITH METAL CLAD TYPE CABLE. 41. VERIFY CLEARANCES FOR ALL NEW OR EXISTING RELOCATED ELECTRICAL WORK BEFORE Q J w 0 w °- PROCEEDING WITH CONSTRUCTION. COORDINATE USAGE OF AVAILABLE SPACE WITH ALL TRADES. IN ORDER ALL LIGHT FIXTURES FROM: o N CL W Q \ 25. NOT USED. THE EVENT OF CONFLICTS, NOTIFY THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH THE CS ILLUMINATIONS Q __D WORK. LIGHTING FIXTURE SCHEDULE . SECURITY LIGHTING SYSTEMS, INC. PHONE: 760-477-124426. WIRE NUMBER 8 AND SMALLER FOR USE IN INTERIOR DRY LOCATIONS SHALL BE TYPE THWN PHONE: 1 -800-LIGHT-IT EMAILS: MCD@CSILLUMINATIOINS.COM THERMOPLASTIC 60C, VOLT INSULATED COPPER CONDUCTORS. FEEDERS AND POWER WIRING 42. WHERE EXISTING CONDUIT IS SHOWN ON THE DRAWINGS, IT IS SHOWN DIAGRAMMATICALLY. THE EMAIL: QUOTATION GHT-IT RITYLIGHTING.COM W AILS: LLUMINATION SWAT MCD NUMBER 6 AND LARGER SHALL BE TYPE THW 600 VOLT INSULATED COPPER. WIRE WHICH IS EXACT ROUTING OF THE EXISTING CONDUIT SHALL BE DETERMINED ON THE JOB SITE BY THE INSTALLED IN RACEWAY IN MOIST OR DAMP LOCATIONS SHALL BE THW, 600 VOLT INSULATED CONTRACTOR. LAMPS MANUFACTURER AND Lo COPPER CONDUCTORS. NO WIRE SMALLER THAN NUMBER 12 AWG SHALL BE USED FOR LIGHTING MARK SYMBOL DESCRIPTION DIFFUSER MOUNTING m OR POWER. 43. NOT USED WATTS TYPE CATALOG NUMBER z 27. BRANCH CIRCUIT HOMERUN WIRING: 44. ALL HANGER AND/OR ROD SUPPORT SYSTEMS SHALL BE SUPPORTED TO THE BOTTOM RIB OF THE F2 2' X 4' GRID TROFFER PRISMATIC 44W LED RECESSED SECURITY LIGHTING: # LCAT24-35HLG-EDU-WP-GK Y A. GENERAL PURPOSE BRANCH CIRCUIT HOMERUNS CONSISTING OF TWO NETWORKS SHALL METAL DECK, WHERE APPLICABLE. ACRYLIC u HAVE PHASE, NEUTRAL AND GROUND CONDUCTORS INCREASED TO NUMBER 10 AWG, THWN a AS A MINIMUM. WHERE HOMERUN (ONE OR MORE NETWORKS) EXCEEDS 100 LINEAR FEET, 45. PROVIDE A WRITTEN GUARANTEE THAT THE ELECTRICAL INSTALLATION IS FREE FROM MECHANICAL F7 1 ' X 4' GRID TROFFER PRISMATIC 44W LED RECESSED SECURITY LIGHTING # LCAT14-35HLG-EDU-WP-GK CONDUCTOR SIZE SHALL BE INCREASED ONE TRADE SIZE. AND ELECTRICAL DEFECTS. CONTRACTOR AT THEIR COST SHALL REPLACE AND/OR REPAIR, TO THE ACRYLIC w B. ALL BRANCH CIRCUITS, FEEDERS, AND HOMERUNS SHALL BE PROVIDED WITH AN SATISFACTION OF THE OWNER AND/OR THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, ANY Q INSULATED CCPPER GREEN GROUNDING CONDUCTOR ROUTED IN THE SAME CONDUIT. PARTS OF THE INSTALLATION WHICH MAY FAIL WITHIN A PERIOD OF 12 MONTHS FROM z GROUNDING CONDUCTOR SHALL BE SIZED PER THE REQUIREMENTS OF NEC SECTION •250. CONSTRUCTION ACCEPTANCE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, PROVIDED THAT L2 no 2 HEAD DOUBLE GIMBALL - 14W LED RECESSED SECURITY LIGHTING # GM2-120-LM-30-SBS Q o z N C. HOMERUN LENGTH SHALL BEGIN AT THE CENTRAL POINT OF ALL DISTRIBUTED CIRCUITS SUCH FAILURE IS DUE TO DEFECTS IN MATERIAL, WORKMANSHIP, OR FAILURE TO FOLLOW THE NOT USED FOR ALL DECORS. VERIFY WITH PHOTOMETRIC Q z z w TO THE PANELBOARD CIRCUIT BREAKER. SPECIFICATIONS, MANUFACTURER'S INSTALLATION INSTRUCTIONS AND/OR DRAWINGS. J j L2R (v> 4" LED DOWN LIGHT - 16W LED RECESSED SECURITY LIGHTING # RDA-136LM-30-FL-S/RDA-136-H L Of VERIFY DOWNLIGHT TO BE USED WITH PHOTOMETRIC o w o a � = 0 mi F20 ® �®� EXIT SIGN WITH BATTERY - 1 .8W LED SURFACE SECURITY LIGHTING: EVEURWE. SEE NOTE LS2 ON THIS Imo- m L_ w o BACKUP SHEET. O 0 Z o N co J W F21 2 HEADED EMERGENCY - - LED SURFACE TO SECURITY LTG. #EV4D N-)WALLa I v� BATTERY LIGHT CEILINGOR w N � i O X v) o x w EMERG BATTERY & 2 - - LED SURFACE TO �~- N W o " ``' uo o F22 � WALL OR SECURITY LTG. #EV4D-02L-0/EVODB REMOTE HEADS SOFFIT F23 2 HEADED EMERG LIGHT - _ LED SURFACE TO SECURITY LTG. #EV4D/EVODB -4 v, 2 REMOTE HEAD IF REQ'D SOFFITWALLOR = E 1 0 �I `/) GENERAL NOTES GENERAL NOTES I m 1 . SEE ELECTRICAL SCHEDULE FOR PANEL & CIRCUIT BREAKER ASSIGNMENT, VOLT/PH, FLA, BREAKER SIZE, COND/WIRE, RECEPTACLE TYPE, HEIGHT ABOVE FINISHED FLOOR, REQUIREMENTS & REMARKS FOR ALL ELECTRICAL EQUIPMENT. AP-1 - 2. VERIFY OEP DROP CORDS DO NOT FALL BELOW HEIGHTS LISTED MDP AP-2 F ON ELECTRICAL SCHEDULE. RECEPTACLES SHOULD BE LOCATED AT HEIGHTS TO AVOID CONTACT WITH HOT APPLIANCES. ❑3 _ __ ____ ___ 3. RE-USE EXISTING CIRCUITRY AND BREAKERS. CONFIRM FIELD VERIFY 3'-0" NEC AMPERAGE AND BREAKER SIZE AS SHOWN ON SCHEDULE. IF REQUIRED CLEARANCE IN FRONT NONE, PROVIDE NEW CIRCUIT BREAKER AND WIRE. z ❑3 OF ELECTRICAL EQUIPMENT. N O COORDINATE WITH ACM/OWNER DEMOLITION NOTES a_ FOR RELOCATION OF OBSTRUCTIONS. U D1 . THE ELECTRICAL CONTRACTOR SHALL RELOCATE EXISTING Ld POWER, DATA, AND TELEPHONE DEVICES IN THE BATHROOM o AREAS TO BE AFFECTED. REFER TO DEMO PLAN D1 .0 FOR AFFECTED AREA. FIELD VERIFY LOCATIONS OF EXISTING ;` D2. THE ELECTRICAL CONTRACTOR SHALL RELOCATE EXISTING POWER PANELS POWER, DATA, AND TELEPHONE DEVICES FOR THE WALL RELOCATION. REFER TO DEMO PLAN D1 .0 FOR AFFECTED AREA. \ \ ❑3 KEY NOTES W O O I Q F REUSE EXISTING CIRCUITRY FOR RELOCATED KIOSK. o 1 a USEDYPROVD IF TE0NAL 2#12T1#12BLE TGRDK & 1#12ER EM IS SOLATEO BE D GIRD. IF I w NEW DIGITAL MENU BOARD. AVAILABLE SPARE 20A/1 P BREAKER WITHIN CP PANEL. CONNECT III REUSE EXISTING CIRCUITRY CIRCUIT TO TWO (2) IG RECEPTACLES, ONE (1) RECEPTACLE FOR _ AND CONTROL. REFER TO 7 8 SERVER TYPICALLY LOCATED IN I.T. CLOSET AND ONE (I)RECEPTACLE DIGITAL MENU BOARD DETAIL ( ( ) 0� 1Ct1l>� LL== ON SHEET E4.0. FOR MONITOR (TYPICALLY LOCATED AT PICKUP COUNTER). COORDINATE -------- - - - EXACT LOCATION(S) IN THE FIELD AND REQUIREMENTS WITH c " � COD MANUFACTURER'S INSTALLATION INSTRUCTIONS. ,•7 cr_ ❑3 a EXISTING POWER IN THIS AREA TO REMAIN. 3 REUSE EXISTING FRONT COUNTER CIRCUITS WHERE POSSIBLE. REFER AAP-3:(1 ,3) � 1TO DETAIL ON SHEET E4.0. PROVIDE (3) 20A, 120V I.G. CIRCUITS M1 I FROM PANEL CP TO FEED FRONT COUNTER POS EQUIPMENT, TABLE 1 7/23 TRACKERS AND UBER TABLET. (1) 20A, 120V CIRCUIT FROM A SPARE IT IS A VIOLATION OF THE NEW 225A 3PH 120/208V 42 k' LAW FOR ANY PERSON, SPACE PANEL AP-3. CONFIRM C/B IN AN AP PANEL TO FEED 2 DCO'S SERVING THE BAKED GOODS UNLESS ACTING UNDER THE LOCATION WITH ACM. FIELD VERIFY J I 5 DISPLAY. IF THERE IS NOT SUFFICIENT CAPACITY IN THE EXISTING DIRECTION OF A LICENSED 3'-0" NEC WORKING CLEARANCE. - - COMPUTER PANEL FOR THE NEW COMPUTER CIRCUITS, THEN ARCHITECT, TO ALTER AN ITEM REFER TO ONE LINE DIAGRAM ON 4 41 CONTRACTOR IS TO REPLACE THE EXISTING PANEL WITH A NEW 42 IN ANY WAY. SHEET E4.1 . MATCH EXISTING MDP - CIRCUIT PANEL OF THE SAME AMPACITY AS THE EXISTING. NEW PANEL AIC RATING. -- li SHALL BE OF THE SAME MAKE, MODEL, MANUFACTURER AND HAVE a. Z I III THE SAME AIC RATING AS THE EXISTING PANEL. N Q ELECTRICAL RACEWAY PROVIDED WITH COUNTER AND INSTALLED BY RELOCATE/REUSE EXISTING - ( CP:* -) _. ___ -_ II 5 E.C. REFER TO DETAIL ON SHEET E4.0 ELECTRICAL CIRCUITRY FOR THE ' - ---- KITCHEN EQUIPMENT ASSOCIATED , 2 _ _ _ WITH THE SERVICE AREA ij; : ' - - - - - - - REFER TO SERVICE AREA ELEVATION DETAIL ON THIS SHEET FOR 0 11 El El El MODERNIZATION. No ADDITIONAL I 9 000 000 0D0 _I DIMENSIONS OF ORB MONITOR, DIGITAL MERCHANDISER AND DMB'S i LOADS WILL BE ADDED. ! L - - - - - - - - - � I - - - - - -� I ROUGH-INS. DUAL POINT FRONT I EXISTING 3 € 600A I COUNTER LAYOUT CONFIRM I Main I El CONTRACTOR TO PUNCH HOLES IN SERVICE POD FOR CABLE AND LAYOUT WITH MCD Distribution CONDUIT ROUTING. UTILIZE BUSHINGS PROVIDE WITH SERVICE POD TO m❑3 `\, I Panel I CONSTRUCTION SUPERVISOR I _ I PROTECT CABLES. °' N 9 E REFER TO DETAIL ON SHEET E4.0 NEW I gin_ -m I Q pogo PANEL AP-3 I I_ _LF _❑� _I I ❑ EXTEND 2 1/2" CONDUIT FROM V-2" AFF TO ABOVE CEILING FOR w 2 E Q d I_ _�_ _�� _I I 8 POS DATA CABLES. IF THERE IS NOT ENOUGH SPACE IN WALL TO a_ � �� I_ � _ _�� _I I PROVIDE 225A _ ROUTE CONDUIT TO ABOVE CEILING, CONTRACTOR TO TRENCH TO -- - I EU ru_ I 3-POLE C/B NEAREST FULL HEIGHT WALL AND EXTEND 2 1/2" CONDUIT TO ABOVE o -0 - - - - FOR PANEL CEILING. z o ° I u! _ I AP-3. MATCH L L ° N c N EXISTING AIC 0 o o 0 ° o 1 ELECTRICAL POWER PLAN RATINGS. 1 .5" CONDUIT AND BOX FOR RELOCATED ORB. REUSE EXISTING U Q ° N 6� I I L� I I PROVIDE 225A 9 E 1 . 1 - I - -❑- - -{ ( (1)#4 GND, J L o � o 1 /4 - 1 -0 FEEDER (4)#4/0, POWER AND DATA. N Q L ° ° I NEW AP-3, 225A, I I (1)#4 ISO GND E° a 3 'o N 42 SPACE PANEL I I ( IN 2-1/2"C TO a .NEW PANEL '�°' c ° I I LOCATION ro F_ ° WITHOUT PEAK LOAD INFO BEING AVAILABLE TO DESIGN, PLEASE DEFER o o o 3 6 TO NEC CODE SECTION 220.87: [10o o0Lo - _ I o ° So Doo DDD ELECTRICAL LOAD ION auo oo IF THE MAXIMUM DEMAND DATA FOR A 1 -YEAR PERIOD IS NOT L - - - - - - - Z NEW KITCHEN EQUIPMENT - 4.2 KW V� Q F L7D nE' AVAILABLE, THE CALCULATED LOAD SHALL BE PERMITTED TO BE BASED _ L _ - - - - - - - - - �_ NEW COMPUTER CIRCUITS 2.5 KW ° °'c ° o ° ° x ON THE MAXIMUM DEMAND (MEASURE OF AVERAGE POWER DEMAND OVER TOTAL NET ADDED LOAD - 6.7 KW c� ° A 15-MINUTE PERIOD) CONTINUOUSLY RECORDED OVER A MINIMUM .° -J~.E ' o o 30-DAY PERIOD USING A RECORDING AMMETER OR POWER METER NEW ESTIMATED LOAD KW - 6.7 KW ° Q L CP:* - IF THERE IS NOT SUFFICIENT CAPACITY IN THE EXISTING CONNECTED TO THE HIGHEST LOADED PHASE OF THE FEEDER OR NEW ESTIMATED LOAD AMPS - 18.6 AMPS ° o COMPUTER PANEL FOR THE NEW COMPUTER CIRCUITS THEN SERVICE, BASED ON THE INITIAL LOADING AT THE START OF THE SINGLE LINE DIAGRAM N ° o�'� RECORDING. THE RECORDING SHALL REFLECT THE MAXIMUM DEMAND OF c ° 0 N L L q) CONTRACTOR IS TO REPLACE THE EXISTING PANEL WITH A NEW 42 THE FEEDER OR SERVICE BY BEING TAKEN WHEN THE BUILDING OR N.T.S. o ° ° °o E CIRCUIT PANEL OF THE SAME AMPACITY AS EXISTING. NEW PANEL ♦ SHALL BE OF THE SAME MAKE, MODEL, MANUFACTURER AND HAVE SPACE IS OCCUPIED AND SHALL INCLUDE BY MEASUREMENT OR U o ° o N o 0 THE SAME AIC RATING AS THE PANEL BEING REPLACED. CALCULATION THE LARGER OF THE HEATING OR COOLING EQUIPMENT PANELBOARD: AP-3 NEW LOAD, AND OTHER LOADS THAT MAY BE PERIODIC IN NATURE DUE TO 0 0 o-0.3 0 0 SEASONAL DR SIMILAR CONDITIONS." BUS AMPS:225A EQUIPMENT GROUND BUS o ® -0 T 3 °.° 0 M C MAIN SIZE/TYPE: MLO Q a o c,5 ° VOLTS/PHASE:208Y/12OV,3PH,4W °- °' o- L o ' ° SYMBOLS AND ABBREVIATIONS w ° ° _ ° s ALL ELECTRICAL DRAWINGS ARE BASED ON ASBUILT DRAWINGS AND SCOPE SERVES: KITCHEN � ' �'' PICTURES. E.C. TO VERIFY INFORMATION SHOWN ON ALL ELECTRICAL DRAWINGS LOCATION: BOH MOUNTING: RECESSED IS ACCURATE PRIOR TO INSTALLATION. E.C. IS REASONABLE FOR NOTING ANY SYMBOL DESCRIPTION SYMBOL DESCRIPTION DEMATIONS FROM THESE DRAWINGS AND PROVIDING THE ENGINEER OF RECORD rw N Z o N CKT DESCRIPTION VA/PHASEH WIRE BKR P P BKR WIRE VA/PHASE DESCRIPTION CKT r WI71-I "MARKED UP/CORRECTED" ASBUILTS FOR THE ENTIRE PROJECT SO THAT m o p m � � O w � SINGLE POLE SWITCH, 3W=THREE WAY SWITCH, K=KEYED SWITCHED, TFE "CORRECTED DEVIATIONS" CAN BE INCORPORATED INTO THE ELECTRICAL NO. A B NO. AMP AMP NO. A B C NO. w N L N I� B BUZZER z U' D w N \ 0 VS=VACANCY SENSOR DRAWINGS FOR THE FINAL "RECORD SET". G 1 FROZEN CARE. BEVERAGE 2,080 __ Q cn v a 10 30 2 1 20 SPARE 2 Q N - w � w p �T MANUAL SWITCH (T=THERMAL OVERLOADS) © BUTTON FOR BUZZER I 3 I 2,080 1 20 -- SPARE 4 0 0 W ocl- \ IN-WALL 5 SPARE -- 20 1 1 20 -- SPARE 6 v~i Qcn OT TRANSFORMER o o PULLBOX V- 1 1 /2" EN-LOSURE FOR 7 SPARE -- 20 1 1 -- -- SPACE 8 JB WITH DUPLEX CONVENIENCE OUTLET (FLUSH WITH CEILING) 11�=_ PANELBOARD 9 SPARE -- 20 1 1 -- -- SPACE 90 ORDER READY RE EPTACLE �{ JB WITH SINGLE CONVENIENCE OUTLET O CIRCUIT BREAKER 11 SPACE -- -- 1 1 -- -- SPACE 12 BOARD. E ES m 13 SPACE -- -- 1 1 -- SPACE 14 j JB WITH DUPLEX CONVENIENCE OUTLET A AMPERES I - - - - - - 15 SPACE -- -- 1 1 __ __ SPACE 16 I JB WITH TWO DUPLEX CONVENIENCE OUTLETS ACM AREA CONSTRUCTION MANAGER ILL -1 I I 17 SPACE -- -- 1 1 -- -- SPACE 18 -- - 19 SPACE z SPACE-- 1 1 -- -- 20 G JB WITH SPECIAL PURPOSE OUTLET AFF ABOVE FINISHED FLOOR _ _ 7 21 SPACE i _ _ 1 1 __ __ SPACE 22 JB WITH ISOLATED GROUND OUTLET .� C CONDUIT I I- I _ O I II 23 SPACE -- -- 1 1 -- -- _ SPACE 24 D =IG4700A, O =IG5262 -- - - -- �' = IG4710 '.' =IG5261 '� I 25 SPACE SPACE 26 CCT CIRCUIT _ _ - - - - - J I 27 SPACE 1 1 -- SPACE 28 w INTERCOM `.NATION W/ 3/4"C- TO MAIN STATION EC ELECTRICAL CONTRACTOR I 31 SPACE -_ - 1 1 - SPACE 30 TELEPHONE JACK Q I SPACE Q GC GENERAL CONTRACTOR 33 SPACE _ - - 32 z o ~ 1 1 _ SPACE 34 Q Ln 35 SPACE O JUNCTION BOX - WALL OR CEILING MOUNTED GFI/GFCI GROUND FAULT CIRCUIT INTERRUPTER m I I 37 SPACE __ __ :_ __ SPACE 36 O Z w j z o _ _ - - _ SPACE38 DISCONNECT SWITCH GND GROUND - - - - - - - o - - - 39 SPACE -- __ 1 1 __ __ 40 Q w - + � " - - -- -- SPACE O STUB UP THRU ROOF IG ISOLATED GROUND I 41 SPACE 1 1 SPACE 42 o w o a SUBTOTAL 2,080 2,080 LL_ m w o SUBTOTAL z w Uj o O THERMOSTAT SENSOR W/ 1 j 2"C- UP TO CEILING SPACE JB JUNCTION BOX I TOTAL PHASE A-VA 2,080 LOAD CONN.VA DF LOAD CONN.VA DF O o 00 N 00 MOTOR CONNECTION KES KITCHEN EQUIPMENT SUPPLIER AMPS 17 COOLING 1.00 REFRIGERATION 1.00 Ld Z z aLd CONDUIT RUN CONCEALED IN CEILING OR WALLS MLO MAIN LUGS ONLY TOTAL PHASE B-VA 2,080 HEATING 0 SIGN/DISPLAY 1.25 - o wLn ----...- ---- - --._._.._...... - --- ---- -- ---- -- -- --- .... r� I- _ d _ LJ SERVICE POD AMPS 17 LIGHTING 1.25 KITCHEN 4,160 1.00 N C/) 12 0- o CONDUIT RUN IN FLOOR SLAB WP WEATHERPROOF TOTAL PHASEC-VA RECEPTACLES 1.0/.5 EXISTING 1.00 w O X vvi o � Uj - I Frl OUTLINE AMPS MOTORS 1.00 LARGE MOTOR 1.25 TOTAL DEMAND F_ N Li 1 o w v~-i 0 11X HOT (SHORT), NEUTRAL (LONG), EQUIP GIRD (LONG WITH DOT), & CO CARBON MONOXIDE SENSOR TOTAL PNLBD-VA 4,160 SUPP HEAT _- 1_00 SHOW WNDOW 1._25 4,160 VA & 'x' DENOTES ISOLATED GRD 2 SERVICE AREA ELEVATION J-BOX WITH FINAL EQUIPMENT CONNECTION �� �� " _ AMPS 12 M►SC EQUIP 1.00 LTG TRACK 1.00 12 A o os E 1 . 1 1 /4 = 1 -0 G GFCI PROTECTION z CEILING MOUNTED OCCUPANCY SENSOR w • DUPLEX USB CONVENIENCE OUTLET POWER PLAN c L M AP-1 DP AP-2 F2 El El L F22 F20 M_Z� 5 TYP. Li FIELD VERIFY LOCATIONS OF EXISTING POWER PANELS [3] F-31 F 131 IT IS A VIOLATION OF/7/23 THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED F-31 ARCHITECT, TO ALTER AN ITEM IN ANY WAY. AP-3 CL u EXISTING EMERGENCY LIGHTS TO REMAIN r -!-I ? ELECTRICAL CONTRACTOR TO FEUSE EXISTING FIXTURES IF 0 POSSIBLE OR MATCH EXISTING SERVICE AREA FIXTURES AS u 7 SHOWN. REUSE EXISTING SERVICE AREA CIRCUITRY AND CONTROLS KEY NOTES EC SHALL INSTALL AND CONFIGURE REMOTE EMERGENCY Fil LIGHTING AT ALL EGRESS EXTERIOR DOORS FOR MAXIMUM ILLUMINATION AT POINTS OF EGRESS. INSTALL WP J-BOX m E 0 IT TO ALLOW A FLUSH INSTALLATION OF ANY TYP. WITHIN SOFFIT LLJZg ft� a a5 EXTERIOR EMERGENCY EGRESS LIGHTING (TYPICAL). USE < CN EXISTING EMERGENCY CIRCUITRY FOR NEW EMERGENCY LIGHT. L'i D 023 El ALL SOFFIT LOCATIONS, LIGHTING, & SUPPLY GRILLS SHALL BE COORDINATED WITH DECOR COMPANY DRAWING PRIOR TO 0 ELECTRICAL CONTRACTOR TO INSTALLATION. 70 REUSE EXISTING FIXTURES IF 0 0 0 POSSIBLE OR MATCH EXISTING EXISTING LIGHTING TO REMAIN. 0 F22 _5 KITCHEN FIXTURES AS SHOWN. 73 Q-) 5 q�) 1 2 - 0 REUSE L — — — — — — 2 0_EXISTING KITCHEN AREA PROVIDE LIGHTING INVERTER FOR USE WITH FIXTURES SHOWN SHADED OR 0 CIRCUITRY AND CONTROLS T_ mj - Q) Q-1 El SLASHED. MODEL #LG125T SHOULD BE USED FOR L2, L2R, L4 & F12G 6 10 -0 (D ch LE c V E 'o E% C) :3 2 U) WITH NOT MORE THAN EIGHT DOWNLIGHTS CONNECTED TO EACH INVERTER, CO) U) \22 IF DECOR USES ALTERNATE FIXTURES, COORDINATE INVERTER TO BE USED Q) Q) V) WITH LIGHTING SUPPLIER. E.C. SHALL VERIFY THE QUANTITY OF FIXTURES E THAT CAN BE CONNECTED WITHOUT EXCEEDING OPERATING CAPACITY OF 30 UNIT AND PROVIDE ADDITIONAL CIRCUITS AND INVERTERS AS REQUIRED 0 c: w u F20 w c 2 (TYPICAL). Q) -6 0 to -F -c- z 0 c V) U Q) -a 0 c-0 0 E REUSE EXISTING EMERGENCY LIGHTING CIRCUITRY FEEDING THIS 11 5] c u E' 0 0 0 'v o- X —ERA AREA FOR EXIT SIGN. 13 C: 0) _c co 0 _J� 3 -1 0 EMERGENCY LIGHTING NOTES <cf).0 ' Q)v) EL1. EC SHALL INSTALL A LOCK ON CIRCUIT BREAKER HANDLE, FOR ALL 0 EMERGENCY LIGHTING CIRCUITS. EC SHALL VERIFY ALL Q U) -2 aa) Q) REQUIREMENTS AND FINAL EMERGENCY LIGHTING LOCATIONS WITH _0 2 E LOCAL AUTHORITIES. INCLUDE ALL COSTS IN BASE BID. --� - 2 I u A " " 11, 0 _E EL2. IF NOT INSTALLED BY MANUFACTURER, EC SHALL BE RESPONSIBLE w — a_ FOR THE COMPLETE INSTALLATION OF THE EMERGENCY Q) — u ELECTRICAL LIGHTING PLAN INVERTER IN 0 0 0 0 0 NIGHT LIGHTING FIXTURES SHOWN ON THIS SHEET. Q) :3 Q) 0 0 E2.0 1 /4" 1 '_0" U) 0< U) EL3. LED FIXTURES DENOTED AS NIGHT LIGHTING OR SWITCHED a) uj �c 0 EMERGENCY SHALL BE CONNECTED TO AN INVERTER. INVERTER cl� - C V) SHALL BE CAPABLE OF ILLUMINATING FIXTURE FOR 1.5 HOURS TO COMPLY WITH NEC SECTION 700 AND UL924. uj r-, EL4. EMERGENCY BATTERY LIGHTING WALL PACKS IN PLAYPLACE SHALL BE N 0 m 0 0 Li " U �; L' N 0 (n (14 ­3 "t LOCATED SO AS TO PROVIDE FOR MAXIMUM ILLUMINATION OF AREA. zo D 2 n EC SHALL VERIFY EXACT PLACEMENT IN THE FIELD WITH McDONALD'S < CD U) -i uj 0 SEE DRAWING E1 .0 FOR ACM. (IF APPLICABLE) 6 LIGHTING FIXTURE SCHEDULE EL5. EMERGENCY LIGHTING HAS BEEN DESIGNED PER NFPA 101 TO V) (.3 AND GENERAL NOTES. MAINTAIN 1 FC IN PATH OF EGRESS. IF FIELD CONDITIONS REQUIRE ANY CHANCES TO LIGHTING DESIGN, EMERGENCY LIGHTING, SHALL BE INSTALLED TO MEET THE ABOVE REQUIREMENTS. CN Ln PROJECT DEMOLITION NOTES : z THE FOLLOWING PROVIDES A GENERAL SCOPE OF WORK FOR THE F21 ELECTRICAL CONTRACTOR FOR THE DEMOLITION REQUIREMENTS OF THIS GENERAL NOTES FOR DRAWING E2 . 0 : SITE. THIS SECTION IS NOT ALL INCLUSIVE, AND THE CONTRACTOR SHALL VISIT THE SITE AND COMPARE EXISTING CONDITIONS TO THE LIGHTING REQUIREMENTS DENOTED ON THE CONSTRUCTION DOCUMENTS TO > t� 1. ALL LIGHT FIXTURES SHALL BE 120 VOLT UNLESS NOTED OTHERWISE. DETERMINE THE EXACT EXTENT OF THE DEMOLITION WORK REQUIRED. E.C. Z L_ SHALL PROVIDE ALL DEMOLITION WORK REQUIRED IN ORDER TO ALLOW < z 2. LIGHTING FIXTURES AND LAMPS HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM ENERGY CONSERVATION WHILE MAINTAINING ADEQUATE LEVEL FOR THE COMPLETE INSTALLATION AS DENOTED WITHIN THESE DRAWINGS. >_ OF ILLUMINATION. LAMP SPECIFICATIONS SHALL BE STRICTLY FOLLOWED. ANY DEVIATION FROM LAMP SPECIFICATIONS SHALL BE uj 0�� 0 c� i U) c APPROVED IN WRITING BY McDONALD'S CORPORATION. GENERAL < INSTALLATION METHODS j a� Li c�Q� z iD 0 3. EC SHALL FIELD VERIFY THAT ALL LIGHT FIXTURES SHOWN ON THIS PLAN E Y_ 0 1. THE USE OF "MC" CABLE IN LENGTHS OF D1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SALVAGE M Lj < DO NOT OBSTRUCT OR CONFLICT WITH THE WORK OF OTHER TRADES. 6 FEET OR LESS (WHERE PERMITTED BY REQUIREMENTS FOR ALL EQUIPMENT REMOVED AS PART OF THE 27 L:uj Ln C IF A DISCREPANCY IS FOUND, THE EC SHALL IMMEDIATELY NOTIFY THE 0 0 00 GC BEFORE THE INSTALLATION OF SUCH FIXTURE(S). LOCAL CODES) SHALL BE ALLOWED FOR DEMOLITION WORK WITH THE CONSTRUCTION PROJECT MANAGER. ALL _D U) 00 LLJ WIRING TO THE LIGHTING FIXTURES. EQUIPMENT TO BE SALVAGED AND/OR REUSED SHALL BE PROTECTED 0 v z "ROMEX" OR "BX" SHALL NOT BE USED. FROM DAMAGE UNTIL REINSTALLED OR THE TIME PERIOD WHEN IT IS CL Li LC 4. ORDER LED EXIT SIGNS WITH LETTER COLORS THAT COMPLY WITH LOCAL CODES. 4- W 67 "1 C'j 'j - FOR RED LETTERS USE EVE-U-R (UNIVERSAL), TURNED OVER TO THE OWNER AND THE PROJECT MANAGER. Ld x x V) ui CN - FOR GREEN LETTERS USE #EVE-U-G (UNIVERSAL), OR SPECIALITY LIGHTING D2. SEE THE GENERAL ELECTRICAL SPECIFICATIONS AND NOTES ON SHEET 0 LLJ 0 IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE: LED SIGN WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE & E1 .0 FOR ADDITIONAL GENERAL REQUIREMENTS. DIRECTIONAL ARROWS AS REQUIRED BY THE LOCAL AUTHORITIES. 1. SEE THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND REQUIREMENTS FOR D3. THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE ALL z 5. ALL NON EMERGENCY LIGHTING IS TO BE ROUTED THROUGH THE BUILDING ENERGY MANAGEMENT SYSTEM FOR COMPLETE BUILDING THE FACADE ARCADE LIGHTING ELEMENTS, EXISTING LIGHT FIXTURES IN THE AREAS ASSOCIATED WITH THE ow E2 . 0 LIGHTING AUTO SHUT-OFF AND CANOPY ELEMENTS. REMODEL TO ALLOW FOR THE NEW LIGHTING FIXTURE INSTALLATION AS 11 DENOTED ON THE PLANS AND DECOR DRAWINGS. COORDINATE ALL WORK WITH OTHER TRADES AND WITH THE PROJECT MANAGER. LIGHTING PLAN I � m POS & COD ISOLATED GROUND/DEDICATED CIRCUIT KEY NOTES 4 SOLID #,2 Awc OLIO CONDUCTORS THIS IS THE ONLY POINT WHERE THE ISOLATED • SHOWS CONNECTION/BONDING POINT ONLY. 8 1 EQUIPMENT GROUNDING CONDUCTOR SHALL BE CONNECTED TO THE BUILDING'S GROUNDING SYSTEM, SEE BUILDING GROUNDING DETAIL THIS SHEET. SERVICE ENTRANCE 3 PANEL CP 9 3 1-1/2" METAL CONDUIT: 4-#1 CU + 1-#6 CU 40 (TYPICALLY MDP) COMPUTER ONLY EQUIP GND + 1-#4 CU ISOLATED GND. (ORDER AREA) ELECTRICAL (PICK U P AREA) A B C ALL ISOLATED GROUND/ DEDICATED CIRCUIT RACEWAY (ADJUST t00A-3P RED WRT A B C BLK BLu 10 a RECEPTACLE COVER PLATES SHALL BE ORANGE cRN LW STRIP HUBBELL PJ7C0 (SINGLE), PJ8C0 ONE DUPLEX OR LIN TO BE 1 LESS rm` BLu cRN PJ82CO (TWO DUPLEX) MARKED "COMPUTER ONLY". O THAN COUNTER WHT METAL JUNCTIO 11 LENGTH) 4 AWG GRN GR STRIP BOX METAL CONDUIT SHALL CONTAIN ONLY P.O.S. CIRCUIT 0- cRN 12 � CONDUCTORS (DEDICATED CIRCUIT). ONLY USE RIGID 0!� NON-METALLIC CONDUIT BELOW GRADE WHEN U J-BOX/S ELECTRICAL J-BOX S cRN YLw N 5 13 REQUIRED BY LOCAL CODE. Q ( ) EQUIPMENT GROUNDING BONDING CONDUCTOR FOR POWER _ _ _ RACEWAY TO BE FOR POWER 6 E (TYPICAL) PULL BOX INSTALLED ON PULL BOX N ISOLATED GROUND BUS, ELECTRICALLY INSULATED FOR DATA HORIZONTAL FOR DATA FROM PANEL ENCLOSURE USED TO TERMINATE ONLY ® ® ® ® FRAMING ®a ® 7 ISOLATED EQUIPMENT GROUNDING CONDUCTORS. ❑ ALL CONDUCTORS SHALL BE SOLID COPPER AND o MEMBER OR A 1 8 TERMINATED TO THEIR APPROPRIATE TERMINAL SCREWS PIECE OF UNISTRUT BY WRAPPING THE CONDUCTOR COMPLETELY AROUND I THE SCREW BARREL AND TIGHTENING THE SCREW PER 2 MANUFACTURER'S TORQUE SPECIFICATIONS. ❑ ISOLATED GROUND RECEPTACLE LL! T18" NOTES 9 ROUGH IN SCHOEDULE FOR THE APPROPRIATE ATE SEE I Q 8�t 1. ALL P.O.S. EQUIPMENT (COMPUTERS,PRINTERS,MONITORS RECEPTACLE TO USE. KVS, MODEM, HUB & COD) SHALL BE POWERED FROM 6. EC SHALL VERIFY THAT SUBPANEL CP DOES NOT CONTAIN THE COMPUTER PANEL. ANY ILLEGAL NEUTRAL TO GROUND BONDS. 10 ISOLATED GREEN GROUND SCREW. I W SYMBOL CATALOG # DESCRIPTION QUANTITY ALL OTHER COMPUTER DIGITAL EQUIPMENT SHALL BE 7. PANEL CP SHALL ONLY BE USED TO POWER SENSITIVE 11 ISOLATED EQUIPMENT GROUNDING CONDUCTOR (GRN m POWERED FROM PHASE "A" IN THE COMPUTER PANEL. ELECTRONIC EQUIPMENT, AS OUTLINED IN NOTE #1. IT W/YLW STRIP) 0 HBLALU57DR & IG4700 RECEPTACLE COVERPLATE WITH ORANGE, 1 PER ISOLATED GROUND RECEPTACLE SHALL NOT BE USED TO POWER ANY OTHER LOADS. 12 NEUTRAL CONDUCTOR TERMINATED ON SILVER SCREW. tad Iw. TWIST LOCK, ISOLATED GROUND 2. ISOLATED GROUND INSTALLATION SHALL COMPLY WITH THE PHASE CONDUCTOR TERMINATED ON BRASS SCREW DUPLEX RECEPTACLE POS SYSTEM TO HAVE ITS OWN INDEPENDENT GROUNDING �r REQUIREMENTS OF NEC SECTION 250 8. IT IS A SAFETY HAZARD AND AN NEC VIOLATION FOR THE 13Ca HBLALU57DR & 5-15R RECEPTACLE COVERPLATE WITH 1 3. EACH 20 AMP CIRCUIT SHALL HAVE IT'S OWN ISOLATED ROD. IF AN INDEPENDENT GROUND ROD IS FOUND FOR :. ?1 STRAIGHT BLADE DUPLEX RECEPTACLE EQUIPMENT GROUNDING CONDUCTOR. THE POS SYSTEM, IT SHALL BE BONDED TO THE BUILDING GROUNDING SYSTEM. 0 HBLALU57LPB COMMUNICATIONS COVERPLATE 1 PER REGISTER & 1 FOR DUAL POINT 4. ENTIRE GROUNDING SYSTEM SHALL COMPLY WITH NEC 0 HBLALU57BL BLANK COVERPLATE AS NECESSARY TO FILL RACEWAY ARTICLE 250 AND MCDONALD's BUILDING GROUNDING ���j358c�1 DETAIL. 0 HBLALU7620B03M290 3' SECTION OF RACEWAY. INCLUDES AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1 ' LESS THEN COUNTER COUPLERS LENGTH. INSTALL (1) 3' RACEWAY AT PICKUP 5. EC SHALL VERIFY CORRECT POLARITY AT RECEPTACLE. 41 1/7/23 IT IS A VIOLATION OF THE 0 HBLALU7620B02M290 2' SECTION OF RACEWAY, INCLUDES AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1 ' LESS THEN COUNTER LAW FOR ANY PERSON, COUPLERS LENGTH. INSTALL (2) 2' RACEWAY AT ORDER UNLESS ACTING UNDER THEDIRECTION of A LICENSED ® HBLALU761OB BLANK END FITTING AS NEEDED ARCHITECT, TO ALTER AN ITEM IN ANY WAY. ® HBLALU5010132M2 SERVICE ENTRANCE FITTING & BUSHING AS NEEDED 4. FOR DATA CABLES = a_ CR N/A HBLALU5701 COUPLER (INCLUDED WITH RACEWAY RECEIVE 1 PAIR PER RACEWAY SECTION J F SECTION) j AS NEEDED B = x VIF = Verify in Feld U B Junction Box ELECTRICAL SCHEDULE -�« ; ° N/A HBLALU5709 GROUND ADAPTER J EC = Electrical Contractor TAG # IQTY IDESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS NOTES: 004.2OE3 3 MENU BOARD - DIGITAL 120/1 5. - } 1 . RACEWAY AND RECEPTACLES TO BE PROVIDED WITH MODULAR FRONT COUNTER, INSTALLED BY CONTRACTOR. ISOLATED 3 20A - (2> IG5262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION 004.21 E1 3 MENU BOARD - DIGITAL - MEDIA PLAYER 120/1 1.0 20A (2) IG5262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION 2. DETAIL SHOWN IS A TYPICAL CONFIGURATION ONLY. SITE SPECIFICS MIGHT CAUSE DEVIATIONS. SHORTER COUNTERS MAY REQUIRE CONTRACTOR ISOLATED TO CUT RACEWAY FOR RACEWAY TO BE 1 ' SHORTER THAN COUNTER. zls.osEe 1 ORB MONITOR ISOLATED 1.5EA 20A - - (1) IG4700 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION ISOLATED MUL) ULA C UNTE RAC [ A� TCN Lo f g NOTE OPTION 2: � �° JB WITH (2) 2 1/2" CONDUIT TO a z DETAILS SHOWN ARE TYPICAL JB WITH ONE (1) ABOVE CEILING WITH BUSHINGS FOR w ° 5 Ep"ppp�� J � V N CONFIGURATION ONLY. SITE SPECIFICS 1 1/2" CONDUIT TO 1 '-1 1/2" 216.05 E9 DATA CABLES N P U MIGHT CAUSE DEVIATIONS. ABOVE CEILING WITH 4.20 E3 BUSHINGS FOR DATA ° ° 0 CABLES E E f ° ° �o - - - U 0 C . OPTION 1: ° ° L-0 0 0 r0 4" CONDUIT SLEEVE THROUGH VALANCE WALL v I TO ALLOW FOR PASS THROUGH OF DATA 2 a° o ° CABLE. PROVIDE BUSHING ON EACH END. 0- o °° a o ORDER READY Iv II PASS-THROUGH CAN BE ANGLED AS NEEDED ° ° C BOARD. TO COORDINATE WITH CEILING BEHIND AND o ^ o N N. o - J EXISTING CONDITIONS ° a CL - - r Q C o HDUAL POINT PICK-UP I - c o 1 i i N N a -5 ° ° ° a STATION 4VERSHELF o NEW ELECTRICAL ELECTRICAL - - IN-WALL ENCLOSURE cv o ° °° ° RECEPTACLES FOR MINI (J RECEPTACLE FOR ORB. FOR RECEPTACLE U ° - - - - - -I ORB AND SCANNER 701.13 E3 VERIFY LOCATION IN - - - - - F - Logo °a o NPI ELECTRICAL T- - - --- -- t -I I CEILING. a N ° RECEPTACLE FOR ORB. - - - - - --- - VERIFY LOCATION IN 2 4" 1 4" 3'-0" 2' 7" 2,. J SERVICE POD ° °C Q)� Q) C) C U•� ° 0 0 CEILING. 3'-0" A11tJ. 2'-8" MIN. 2'-B" MIN. OUTLINE v I- L i ra N_ ro f� f0 r�f� r°r� r�r� I :3) rn c0(I Ui Lp C3T 1Q CJ CST C31 4-'-0" STD. 3'-0" STD. 3'-C" STD. .O C N ° O lo- Q c : Q) (� r 00 O OO �� •O U) O p N � U7 0 0 0 0 0 o 0 CD0 5'-0" MAX. 3'- 0" 3'-4" MAX. 3'-4- MAX. '-2'_ O ° C:" OO m m CA m crnJm ° °- �3" (ADA HOLD) n .N w C -, I -� OVERALL COUNTER LENGTH VARIES 0 -c° OVERALL COUNTER LENGTH VARIES H L yr ° o ° a tn �o Q o 21111 ECHART FRONT COUNTER ELECTRICAL ROUGH-INS FRONT COUNTER WITH DUAL POINT IMCORPORATED NOTE: OPTION 1 IS PREFERRED IF AREA BEHIND BOARDS IS A � o � �_° �a_ ! N5 NS SURFACE MOUNT MENU BOARDS NON-CUSTOMER AREA AND MEDIA PLAYERS WON'T BE INSTALLED ABOVE o 3 a) E w C) - 3 NTS FOOD PREP. SLEEVES SHOULD NOT BE INSTALLED WITHIN CUSTOMER L` ° ° 3 ° Q ° ° o VIEW. IF AREA BEHIND MENU BOARDS IS DINING, RESTROOMS, OR ® O•0 a N C: SAMPLE ELECTRICAL SCHEDULE OTHER CUSTOMER-FACING LOCATION, USE OPTION 2. 0- N :3U) TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/'WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS LJ I-- -� ° ° 3 0 C 215.01DE1 4 POS PC HARDWARE - FRONT COUNTER 12011 3.0 EA., 20A 1/2"C-2#121G CP:17 I1347DD 2'-D" EC TO RUN 3/4" COND IN WALL FOR FLUSH MTD SPCL. RECEP a ISOLATED FOR KEYSTATIONS (MONITOR,CPU & CASH DRAWERS) w 215.ODE6 1 POS PC HARDWARE - FRONT COUNTER DATA CABLE - - - - 4x4x4 PB 1'-6" EXTEND 2 1/2" CONDUIT UNDER SLAB TO 215.10DE7 FOR POS DATA p D OPTION 2: JB WITH ONE (1) 1" CONDUIT r o N m O N U 216,04E1 1 ORB MONITOR (MINI) 120/1 1.5 EA. 2DA 1j2"C-2#121G CP:17 IG47DD 1'-6" CABLES O o a o o JB WITH (2) 2 1/2" TO ABOVE CEILING WITH m w 0 � co ON p CONDUIT TO ABOVE BUSHINGS FOR DATA CABLES ISOLATED ® o0000 CEILING WITH Q V) -I w CD w a M 216.05E1 1 ORB MONITOR 120/1 1.5 EA 20A 1 jz"C-2#121G CP:4 IG47DD FLUSH ON 6 G BUSHINGS FOR DATA Q N _CC w � Q \ p ISOLATED CLG CABLES o O Q 219.DDE3 4 POS - RECEIPT PP.INTER/CASHLESS 120/1 D.7 20A 1,/2"C-2#121G CP:4,B SEE RMKS IG47DD 2'-0" FOR RECEIPT LOCATED IN FRONT COUNTER POWER FROM CP:4 IN 4 1 Q N ISOLATED PRESENTER'S BOOTH CP:4 MEDIA PLAYER 701,13E3 1 DCQ - GENERAL PURPOSE 120/1 1.5 20A 1j2"C-2#12 AP-2:0 5-20R V-6" - "v o 0 0 oo as o0 0 o I Iin, DUAL POINT CONVERSION NOTES:1 . ADDITIONAL PO+VER FOR CREW MINI-ORB AND SCANNER LOCATED UNDER COUNTER. SEE 216,04/DETAIL 1 (ELECTRICAL ROUGH-INS) BOTTOM OF VALANCE 2. ADDITIONAL POWER FOR CUSTOMER ORB MONITOR INSTALLED AT FACE OF SOFFIT. SEE 216.05/DETAIL 1 (ELECTRICAL ROUGH-INS) V-5" 3. SEQUENCE MENU BOARDS PER DUAL POINT STANDARDS OPTION 1: HORIZONTAL DIMENSION'S z 4. NON-SEEQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH CBB CELL WITH 1 OF 12 APPROVED LAMINATE SELECTIONS. KES TO ORDER FROM DECOR 4" CONDUIT SLEEVE REFERENCED FROM LEFT Y THROUGH VALANCE WALL COMPANY- (VERIFIED AT TIME OF SURVEY) TO ALLOW FOR PASS 5. SEEQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH DECOR FRONT COUNTER CORIAN SPECIFICATION. GC TO FABRICATE AND INSTALL TO THROUGH OF DATA CABLE. a *SECURE TO EXISITING STUDS OR 3 4 PLYWOOD BACKING PROVIDE BUSHING ON g SPECIFICATIONS. (LINEN OR RICE PAPER) / �� EACH END. SLEEVE CAN 6. SIGPJAGE PACKAGE PROVIDED BY KES AND INSTALLED BY G.C. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS BE ANGLED WHEN j 7. ADA PLATFORM SOLUTION DOES NOT MEET ADA REQUIREMENTS IN CA, IL OR FL. NECESSARY Q z 8. 3'-D" MINIMUM ADA SPACE REQUIRED BETWEEN END OF PICK-UP SHELF AND FIRST KEYSTATION Q o z N 9. ORDER READY BOARD TO BE CENTERED ON PICK-UP SHELF OR ADA PLATFORM. DIGITAL MENU BOARD BRACKET DETAIL BACK OF WALL VALANCE z w z O C) o w THIS SLIP SHEET IS PROVIDED FOR REFERENCE ONLY. ADDITIONAL MODIFICATIONS TO THE HLZ, CENTER ISLAND AND POS SYSTEM WILL BE REQUIRED TO -I � W o o z COMPLETE THE DUAL POINT SERVICE INSTALLATION. PLEASE VERIFY LAYOUT, NUMBER OF KEYSTATIONS AND DIMENSIONS WITH KE DIGITAL MENU BOARD (OMB) INSTALLATION NOTES: KEY NOTESS AND REGIONAL DUAL POINT DMB SUPPORT EQUIPMENT INCLUDES: 0 = o Q LEAD PRIOR TO FABRICATION OR INSTALLATION. - NETWORK MANAGEMENT DEVICE (NMD) [!]THIS SLIP SHEET IS PROVIDED FOR ELECTRICAL ROUGH-IN m Iw- w w o - 24 PORT ENHANCED WAYPORT SWITCH (EWS) PREPARATION AND GENERAL DIGITAL MENU BOARD MOUNTING O Z O N Co THIS EQUIPMENT IS TYPICALLY MOUNTED IN GUIDELINES. EVALUATE EXISTING VALANCE WALL STRUCTURE W Q w 00 DUAL POINT FRONT COUNTER PLANS TECHNOLOGY CLOSET OR IN MANAGER'S AND BACKING MATERIALS TO ENSURE ADEQUATE SUPPORT OF Z z v M.T . OFFICE. EQUIPMENT. I- w w Ln • DMB INSTALLERS TO ROUTE CONTROL WIRES FROM (� Ld ❑2 ALL HEADER AND WALL PENETRATIONS FOR CONDUITS N - c w o r NMD/EWS ABOVE CEILING TO MENU BOARD X 0 p w w l VALANCE WALL. WIRES TO EXIT WALL VIA J-BOXES. OR OTHER ELECTRICAL ROUTING MUST BE SEALED TIGHT. N W o � o • EACH DMB SECTION REQUIRES A DEDICATED MEDIA PLAYER. 0 z w E4 * 0 1n ROUGH IN DETAILS