Loading...
HomeMy WebLinkAbout50593-Z �o�oS�ffO^�1 ee Town of Southold 6/8/2024 o - P.O.Box 1179 co 53095 Main Rd 'A Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45269 Date: 6/8/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 39100 Route 25, Orient SCTM#: 473889 Sec/Block/Lot: 15.-8-19 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/19/2024 pursuant to which Building Permit No. 50593 dated 4/25/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Nicoll,Barbara&Curtis,Donald of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50593 5/7/2024 PLUMBERS CERTIFICATION DATED uth rize S gnature TOWN OF SOUTHOLD a�o� �Ooy BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy_• �� SOUTHOLD, NY col � goo. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50593 Date: 4/25/2024 Permission is hereby granted to: Nicoll, Barbara 201 W 89th St New York, NY 10024 To: install generator as applied for. At premises located at: 39100 Route 25, Orient SCTM #473889 Sec/Block/Lot# 15.-8-19 Pursuant to application dated 3/19/2024 and approved by the Building Inspector. To expire on 10/25/2025. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector Of SOGTyOIo �� �V - # TOWN OF SOUTHOLD BUILDING- DEPT. 0, 631-765-1802 I-NSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. ] FOUNDATION 2ND ' [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [- ]=FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) . - [ ] CODE VIOLATION Yl PRE C/O [ ] RENTAL REMARKS: . r DATE 7 117,H INSPECTOR fir �a0f SOUTyo # # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND 4SULATIOWCAU KING [ ] FRAMING/STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR pF SO!/r�ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 117.9 JQ sean.deviinO-town.southold.ny.us Southold,NY 11971-0959 1 �yCOUNTT`I,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Barbara Nicoll Address: 39100 Route 25 city:Orient st: NY zip: 11957 Building Permit#: 50593 Section: 15 Block: 8 Lot: 19 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: REP Electric License No: 46288ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor " Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 100A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 12kW Briggs & Stratton Generator w/ 100A 16 Circuit Generator Notes: Generator Inspector Signature: Date: May 7, 2024 S. Devlin-Cert Electrical Compliance Form FIELD INSPECTION REPORT DATE COMMENTS ro O � FOUNDATION (1ST) A ------------------------------------ C FOUNDATION (2ND) t� z w o C 0 y ROUGH FRAMING& PLUMBING ` r INSULATION PER N.Y. H STATE ENERGY CODE 0-m I FINAL ADDITIONAL COMMENTS 9 a�' O 0 z m X v, �z x d ro H D -ifFOLIf TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 �y�o• �ao�� Telephone (631) 765-1802 Fax (631) 765-9502 hMs://www.southoldtownny.go_v Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: , MAR 9 2024 ._.s.s Applications and forms must be filled out in their entirety. incomplete applications will not be accepted. Where the Applicant is not the owner,an „J ., t -.s ,i,.: Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: C� SCTM#1000- ��— Project Address:,�a 9 Phone#: Email: Mailing Address: CONTACT PERSON: Name: Mailing Address: 60X Phone#: Email: ' DESIGN PROFESSIONAL INFORMATION: ,1 Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: I : '- Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair El Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes I INO Will excess fill be removed from premises? ❑Yes ❑No 1 • 4 PROPERTY INFORMATION . Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(p ' name): ❑Authorized Agent ❑Owner Signature of Applicant: Date: CONNIE D:BUNCH Notary Public,State of New York STATE OF NEW YORK) No.01BU8185050 SS: Qualified In Suffolk County COUNTY OF ) Commission Expires April 14,2Va_ being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this I vE� day of I OK C 1 , 2QQ�4 Notary Public PROPERTY OWNER AUTHORIZATION �- (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) 1, Donald Curtis residing at 160 Cedar Birch Road, (Print property owner's name) (Mailing Address) Orient, New York, 11957 do hereby authorize 'FJ(?0YLC0j C YO (Agent) E QeDf y.C, E.-Lc to apply on my behalf to the ._. ..-., :'•7.3w.. - `;S .•.S» •a" �,.. °ar.L=�_.., =.;5...'Y.y..,>,,.:m x3-,r....«a,.,_ =: ;: � '- -.`,'y"a, .,..- Southold-Building Department. " 03-19-24 (Owner's Signature) (Date) Donald Curtis (Print Owner's Name) �OS�FFQj�CO BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 CM 1 ^ Southold, New York 11971-0959 �'yfj0� Telephone (631) 765-1802 - FAX (631) 765-9502 lamesh(a southoldtownny.gov - seand(a-),southoldtownny.q v APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: 03/18/2024 Company Name: REP Electric LLC Electrician's Name: Robert E Paladino License No.: 46288ME Elec. email:REPelectric1 @gmail.com Elec. Phone No: 631-767-6034 E I request an email copy of Certificate of Compliance Elec. Address.: PO Box 635 Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Nicoll Address: 160 Cedar Birch Rd Orient (39100 Main Rd) Cross Street: Phone No.: 631-767-6034 Bldg.Permit#: 6yw email: Tax Map District: 1000 Section: S Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New 12 KW generator Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES❑ NO Rough In Final Do you need a Temp Certificate?: YES R]NO Issued On Temp Information: (All information required) Service Size❑l Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire Reconnect[]Flood Reconnect Service Reconnect[]Underground Overhead # Underground Laterals Ell 2 H Frame Pole Work done on Service? Y N Additional Information: $100 PAYMENT DUE WITH APPLICATION 4� ,•TAX MAP4- _._ ILL"D-15-;a_19 znwo VOTRIOT R-b0 NO am , 'LOT.AdiEA of,ACRES ,WO-.ONE FAMILY Vkr, a1liw 140..Z4533-1-ZLIARY 23,1912 O P`Q 105 1 Unit. YE7LATD6"DSSTRIGT WA re U DEG DTuTRG7 WA =�_+�`+` ^� $ 'SOT-OL'K COUNTY tO APPRO'/AL No.5290 10/26I?71 r- - �� l►YOITrN P4z£5. s4YwS t...=�5%tC-R...s"i,�sr__ ,..Y -•,-' 3s 3s. i'c' i �� I T I.TN15'15 AN A�N11ErlT9 B1TE'F.A LI 6 15 g e g .13hBmA+%E SPACE EXWIN5 PROfSJe5W �oN� 1 iti' SURVEYT TO VER1F.lOItMA 1 1f.A LiOBLr'ED :+d' .SURVEYS T1E QY9RM5 la I ON TNI NS PLAN TO T1✓3: Ii 9AA97:.AQEA •O SF. 0 5F _� � G ARC1iITE6'T9 flnST OP Kxo KNOi1.E1ME. g 'FIRSTTIOOR-AREA _1^846.F. WAIL 5F. 1 � D 2.5L%ZV-f 11+S-01WA71ON.KA&OBTAIPEO TROM A SURV YPATED NJOMT 11,2022 a $6S 'TOTAL,EEDROOM OOUNT 3 } 2 In AM PREPARW eyc S SCALacE'uuar9LRvErlNs � Sg�Q`- 1 XY_STATE LAN75RVEYOR s'all a L1:..003088$�--•- � �� s i. � 1 z. P�+crs..ru3u 9sr-2.1ao 'DGRJP17ON iPCYT,i32INy +'RE + l.OV62AfiE ! - .L "A TOTAL WT AREA 5F. 1 *` £X1571PL iiG'.13L- 1597 5F. �ib.>. 9 .13 D- 70 ID EXS9i i11:'4h'4A6E 164 W. S2SL - ,�^w'T .•i - iw y PR'JP.O#D H..V55 ADf+!T.IDN ASP_ OJ% ' 1 �-t PROPCJ�D L:Af�FORC.1d Lsl SF. Oh% m `I O +' .:PPOP..PRTIO.(1TBOV=EfiADFJ 1669:`. -0.73 b; Y .PP-lP.PATIO fAT GRAM 3 S52 SP IAJs + R mmx�.ew au ew.+ i .` TOTA6 A5A.Or ALI-5iFL-z7aims 2f Sr. CD tO.TFS 1 C1 f .N R wump v EXSY. PROPOSED .clorl"LIES _ P PRJMARY FRONT YA3W(rWAR 40V 527' 52.7 NO ..BS WH ROPu) SWICHIPARf FRONT YARD 25.0' •ob.7' L'S67' YE5 04AIN ROAD) C� 1 evE YA= 15D' 900 293' YE5 RL -YARD -5o_O' 46b' :+OJ' YES `�r � -mi nc- - dst'vttrG+WOi -`-� IS Oy*y}1 A __�__ ) V> m 2 la00 O W r-A5T. PlBOPOS® cladm!FS �S___C� / _ a�.6 may r•! 'i .md mNwKM 1016471 20' 155' .I5.5' " MNJMII S!C--YARD 15D' 115b' 156' YE3 p7 / a 2aJ z j � Buoy ' M1N7dRM 1�AIR.YAFD 151V 2.9' Y5 MA7t.50UAf'�•7-0OTAG-E �g� -1�D '154D 9F. YS MOP05W SITE MAN A �. o � e a � fl BRIOf38 =T10P1 12kW' STANDBY GENERATOR STANDBY GENERATORS SRIGGS & STRATTOW THE SMART CHOICE y For the discerning homeowner that is looking for the smartest, most reliable permanent backup power solution. FORTRESS" Introducing our dealer exclusive line.Available at your local Briggs a Stratton Dealer With these great features: •The indusuys longest parts,labor and travel limited warranty •Installed di warmer for increased starting protection in colder weather PAM-LAUM-W!AL WMaAM1 Space Saving Design Commercial-Grade Briggs&Stratton Vanguard-Engine •50%smaller than our previous 12kW generator •Powerful VTwin OHV engine B®a/a QUIeter2 •Easy conversion between natural gas(NG)and liquid propane •Re-engineered to be 601/6 quieter than our previous 12kW vapor(LP)during installation Designed for Easy Installation&Maintenance Duality Clean Rawer •Easy to move into installation location with two-wheel dolly •Ensures your electronics are safely powered •Approved for installation as close as 18"to a building3 Corrosion Resistant Enclosure&Base •Removable roof and side panels provide better service access •Made with automotive grade galvanneal steel to resist rust to the engine and alternator •Powder-coated paint for years of protection against chips SymphonyO II Flower Management System and abrasions •Customizable to your home's needs C& •Automatically balances the power of your homes electrical load including high wattage items Ilse air conditioning units and electric ovens LISTED •Offers whole house power with a more affordable home generator GENERATOR SET RATINGS LIQUID PROPANE I NATURAL GAS I LIMITED WARRANTY° MODEL VOLTAGE PHASE HZ BREAKER LP kW LP AMPS NO kW NG AMPS PARTS,LABOR,TRAVEL Fortress 120/240 1 60 60 12 50 10.B 41.7 6 Year 040546 Briggs&Stratton 120/240 1 60 60 12 50 10.8 41.7 5 Year 040517 0 1 This generator is rated in accordance with UL(Underwriters Laboratories)2200(stationary engine generator assemblies) and CSA(Canadian Standards Association)standard C22.2 No.100-04(motors and generators). 'Based on no-load sound power. 3 The installation manual contains specific instructions related to generator placement in addition to NFPA 37,including the 1 requirement that carbon monoxide detectors be installed and maintained in your home. Warranty details available at www.briggsandstratten.com NrLei I 3,� job %��� 22- f (b t j 12kW STANDBY GENERATOR ■■- --) STANDBY GENERATORS SPECIFICATIONSENGINE ENGINE LUBRICATION Engine Model Briggs&Stratton Vanguard" Oil Capacity(ozl 46 Engine Model Type Trim Number 389575-0002E1 Lubrication System Full Pressure Engine Speed(RPM) 3600 Recommended Oil 5W30 Full Synthetic Engine Fuel Liquid Propane(LP)or Low Oil Pressure Sensor Yes 9 Natural Gas(NG) ALTERNATOR SPECS Engine Cylinder Configuration OHV Manufacturer Mecc Alte Number of Cylinders 2 Type Self-Excited.Rotation Field Displacement(cc) 38/627 Voltage Regulator Brushless Bore&Stroke(in) 2.97/2.76 Insulation Class H Compression Ratio B.3:1 CONTROLLER FEATURES Governor Type Electronic Hour Meter Yes Frequency Regulation +/-1 Hz LED Digital Display Yes Valves OHV with Hardened Seats Fault Code Display Yes Ignition System Fixed timing Magnetron® 9 y Electric Ignition' Weekly Exerciser Yes Starter Motor Rating Voltage 12 Volt Battery 12 Volt OPERATIORIS SOUND RATING FUEL CONSUMPTION' AT 7 METERS SO%Load 100%Load 69dBA Liquid Propane 62.1 ft3/hr 1.7 gal/hr 83.8 ft3/hr 2.3 gal/hr Lowest measurement of 12 microphones around generator. Sound level measurement at other locations around generator Natural Gas 117 ft3/hr — 172 ft3/hr j — may be different depending upon installation configuration. Fuel consumption rates are estimated based on normal operating conditions.Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances—fuel flow rates may vary depending on these factors. 2 STANDBY GENERATORS 12kW STANDBY GENERATOR OTHER FEATURES CERTIFICATION Enclosure Material Galvanneal Steel with Corrosion CARE Compliant Yes Resistant Paint Overcrank Protection Yes NFPA Approved Yes Engine Warm Up(sec) 20 or 50 Automatic Transfer cUL Listed to CSA 22.2 NO 100.04 Yes Switch Controlled Engine Cool Down(min) 1 NEMA Compliant Yes Response Time(sec) 26 or 56 Automatic Transfer EPA Certified Fuel System Yes Switch Controlled Monitoring Options Basic Wireless Monitor AVAILABLE ACCESSORIES InfoHub'Monitor Continuous Maintenance Kit 6035 Battery Charging Yes Fortress 6404 WEIGHT AND DIMENSIONS Cold Weather Kit Briggs&Stratton 6348 Assembled Weight(Ibs) 318 Basic Wireless Monitor 6264 Overall Dimensions(in) 28 x 24.4 x 37.2 InfaNub 6260 Packaged Weight(Ibs) 345 Remote Status Monitor 6144 Packaged Dimensions(in) 39 x 35.5 x 45 28" 24.4" i I I I i i �® 37.2" LA I I � • PORTR��O' I I � I I I 1 26.1" 22.5" 3 .nrO4 STANDBY GENERATORS 12kW STANDBY GEIUERATOR FUEL P11PE v . + v THOUSANDS OF v Natural Gas/Inlet Pressure less than 2 PSI/Pressure Drop 1/2"Water Column/Speck Gravity 0.60 1/2"pipe capacity 3/4"pipe capacity 1"pipe capacity 1-1/4"pipe capacity 1-1/2"pipe capacity 2"pipe capacity 20'Length' 118 247 466 957 1,430 2,760 40'Length' 81 170 320 657 985 1,900 60'Length' 65 137 257 528 791 1.520 80'Length' 56 117 220 452 677 1,300 100'Length' 50 104 195 400 600 1,160 Liquid Propane/Inlet Pressure 11"Water Column/Pressure Drop 1/2"Water Column/Specific Gravity 1.50 1/2"pipe capacity 3/4"pipe capacity 1"pipe capacity 1-1/4"pipe capacity 1-1/2"pipe capacity 2"pipe capacity 20'Length' 200' 418 788 1,617 2,423 4,666 40'Length" 137 287 541 1,111 1,665 3,207 60'Length' 110 231 435 892 1,337 2,575 80'Length' 101 212 400 821 1,230 2,370 100'Length' 101 212 400 821 1,230 2,370 'Total length of piping from outlet of regulator to appliance furthest away. ADDITIOMAL lrdFORMATION TRANSFER SWITCH SPECIFICATIONS Prewired 16 Circuit 100 AMP Model#071076 SUPPORT E ■ ■ Standard 16 Circuit 100 AMP Model#071047 OF THE WAY - - - Symphony3 If 100 AMP Model#071071 NEED 800-759-2744 Our technical suppart tPanflis trained to answer Symphony°II 150 AMP Model#071070 questions on our generators,transfer switches d . Symphony®II 200 AMP Model#07106B Voltage Rating 120/240CALL TODAY ■ A FREE Select Circuit:16 HY-HOME ESTIMATE'! Number of Protected Circuits — Symphony®II:Whole House - -- 800-743-4115 UL Approved Yes 111EMA 3R Rated Yes Disclaimer:Not for Prime Power or use where standby systems are legally required,for serious life safety or health hazards,or where lack of power hampers rescue of fire-fighting operations. BRIGGS&STRATTON POST OFFICE BOX 702 MILWAUKEE,WI 53201 USA Copyright©2016.All rights reserved.BS1007-C-11/16 Briggs&Sratton Corp.reserves the right to make changes in specifications and features shown herein,or discontinue the product described at any time without notice or obligation. 4