Loading...
HomeMy WebLinkAbout48163-Z Fat cG. Town of Southold 6/8/2024 y� P.O.Box 1179 0 o _ 53095 Main Rd o Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45261 Date: 6/8/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 400 Pleasant Pl, Southold SCTM#: 473889 Sec/Block/Lot: 88.-5-46 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in.this office dated 7/6/2022 pursuant to which Building Permit No. 48163 dated 8/11/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to May,Kathleen&McDonnell,Matthew of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48163 4/19/2023 PLUMBERS CERTIFICATION DATED Au or' d Signatu TOWN OF SOUTHOLD aye BUILDING DEPARTMENT BE z TOWN CLERK'S OFFICE "oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48163 Date: 8/11/2022 Permission is hereby granted to: May, Kathleen 21 Riverview Dr Newbury, MA 019511808 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 400 Pleasant PI, Southold SCTM #473889 - Sec/Block/Lot# 88.-5-46 Pursuant to application dated 7/8/2022 and approved by the Building Inspector. To expire on 2/10/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100:00 CO-ALTERATION TO DWELLING $50,.00 Total: $200.00 Building Inspector pf SO�j�ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 iQ sean.devlina-town.Southold.ny.us Southold,NY 11971-0959 COUNTi'�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Kathleen May Address: 400 Pleasant PI city:Southold st: NY zip: 11971 Building Permit#: 48163 Section: 88 Block: 5 Lot: 46 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: GreenLogic License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 13.6kW Roof Mounted PV Solar Energy System w/ (32) SunPower SPRM425Module SunPower Monitor, AC Combiner Panel Notes: Solar Inspector Signature: Date: April 19, 2023 S.Devlin-Cert Electrical Compliance Form IXQ�I/f�/J 0FS0Ulyo� TOWN OF SOUTHOLD BUILDING DEPT. �O • �O 631-765-1802 INSPECT-ION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAAULKING [ ] FRAMING /STRAPPING [ FINAL SOJWV-� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR oF soory�6 LI eil los y 00 op/' TOWN OF SOUTHOLD BUILDING DEPT. �oyC N�a� ourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] -FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: tl t C OA< DATE 1411cl IS3 INSPECTOR SO(/TyOlo TOWN OF SOUTHOLD BUILDING DEPT. coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ dF I N A L (90/0,9, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: L G upon ISSvx1rGe- 0-c DATE ANSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) ------------------------------------ Q C FOUNDATION (2ND) �cp z O ROUGH FRAMING& PLUMBING v, e� �r INSULATION PER N.Y. y STATE ENERGY CODE C O Nc,,-o ih W-e,I m i ss�-ed I �- • FINAL ADDITIONAL COMMENTS VO,kd 200 IJ- Zi. o z y y x d b y �0:9o�f TOWN OF SOUTHOLD—BUILDING DEPARTMENT z Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Qy�o f o� Telephone(631) 765-1802 Fax (631) 765-9502 li ps://wwxv.southoldtownny. oovv Date Received APPLICATION FOR BUILDING PERMIT �j For Office Use Only ® F � � VE PERMIT NO. M�✓ Building Inspector: I` ICJ JUL n-6 9n99 -Applications and forms,must be filled out in their entirety,ln'oRni lete., BUILDING DEPT applications will riot be`accepted. Where the Appllcarit�is:nbt the owner,an TOWN OF SOUTHOLD :'Owner's Authorizatibn#orm.,(P.age 21 shall be-cornpleted. - Date: 4 -OWNER(SJ Of PROPERTY:' Name:Kathleen.MaY. ......................................... . scTM#l000-88-5-46 Project Address:40.0 Pleasant Place, Southold, NY Phone#:617-697-9365 Email:kathyµmay,a,massed.net Mailing Address: Riverview Dr, Newbury,MA 01„951 CONTACT_PERSONz Name:Barbara-GreenLogic,LLCax Sea Road Mailing Address:97 North Se Southampton, NY 11 _.. __._._.. ..... ............_. ..�._.._ _.__... .._.� 968........ . .........._ _.._....__....... _ _ ._._.._..._._.._.___..W................. ._... Phone#:631-771-51 52 x117 Email:Barbara@Greenlogic.com ._. bESiGN"PROFESSIONAL 1Nf61111M"'ATIONi Name:James J. Stout Architect & Associates Mailing Address:2 Greg Lane, East,Northport,,.NY 11731„ Phone#:631-858-9388..,,,..._... Email:stouthub@jamesstoutarch.com, ....... CONTRACTOR I N FORMATI ON c Name:vGreen Lo_g ic_LLC Mailing Address:97 North Sea Road, Southampton ,NY 1„1968 Phone#:631-771_-5152 . __......__..... ... .°. _.. Email:AM Greenlogic.com _......._x.. _.... _._ .. .__ DESCRIPTION:Of PROPOSED CONSTRUCTION ❑New Structure ❑Addition RAlteration ❑Repair ❑Demolition Estimated Cost of Project: EOther Solar Panels $ 54,800 Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY-INFORMATION Existing use of property:6,tq Intended use of property: Zone or use district in which premises is situat d: Are there any covenants and restrictions with respect to this property? E]YesEfNo IF YES, PROVIDE A COPY. 0 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):GreenLogic LLC pAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of V) 20 drr Not ry Public , PROPERTY OWNER AUTHOR17ATION = (Where the applicant is not the owner) - Kathleen Ma 1`�`' C��"ed 400 Pleasant Place, Southold i�Y '!1911" I, y�i� residing at do hereby authorize GreenLogic LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. At&" #noyt l�6/zz wner'Viture e OMaryEllen nna Notary COMMONWEALTH OFPrint vner's Name My CommissIV March 1 2 JUL R 'UILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD �uiLDiNG DEPT Town Hall Annex- 54375 Main Road - PO Box 1179 N OF SOUTHOLD Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ro err(c,south oldtownny.gov — seandCc)-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 7/5/2022 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 59krequest an email copy of Certificate of Compliance Address.: 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Kathleen May Address: 400 Pleasant Place, Southold, NY Cross Street: Phone No.: 617-697-9365 Bldg.Permit#: q gl 3 email: kathymay@masstd.net Tax Map District: 1000 Section: 88 Block: 5 Lot: 46 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (32) SunPower SPR-M425-H-AC panels Et (32) SunPower SPR-M425-H-AC micro inverters (1) SunPower PVS6 monitor System Size: 13.600kW Check All That Apply: Is job ready for inspection?: DYES ENO ❑Rough In EFinal Do you need a Temp Certificate?: EYES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION n r 4c' 10W Electrical Inspection Form 2020.xlsx 1 GREENLOGIC° ENERGY July 5, 2022 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Kathleen May 400 Pleasant Place Southold, NY 1000-88-5-46 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, Barbara Casciotta Account Manager Barbara@Greenlogic.com GREENLC � v �e�tlo�ic.com Te1: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 PROP05ED r,-R G SYSTEM DETAIL _ � l ,�m� I ... •"- �.. t � .i..e��ar ru�ovac,� --°° �------------ -----------r--------2 ------ cl —.. O --T •CLEAN-OUT DETAIL / •f.•1 b' / / �sa"is`�^✓..,I've a 's �e• - .. ��. ..�.�... e�.k�..,maR�' ( has P L 0.rcvn a.,m PLEASANT PLACE PFiWECF. AERIAL PHOTO MAY-MCDONNELL SEPTIC SYSTEM SITE PLAN I SUFFOLK COUNTY HEA TH DEPARTI-EW APPROVAL .nw• 400 PLFASFAM PLACE R-21-0641 SOUfNOID,NY 11971 Hip _ ..,.�-„a,,..a,�.. fltOPOSm SF➢11°9YSfE67 Sur—COUNTY DlWR7—Or HEALTH Sm".. � � N.. N�-r M .«.y-.. H'r•'w'�yv rr Ps—F°R A,F;mw�O:Co•sTau:nov FxA �rw+wr y•:__•• -• ..�` �w PAGE' u�n.,i.Fnnmv Roar.ERc.ONLY .-.+.-s..w..w,w...2.".':` >......-..-...�,.....o-..w...«.w�. •.ry.:. a.�"^^.....�.�.a.-. ::+,w: w-++:�...".:.:. I--JE..Fl Awxo-✓to_;.•., ,}:.. "_�- .`F`C.ew...,+..a r..MM� �.v ..,e....e...._ ...w..e%�•.'"....�_. I FOR M+a�e�WQ T4• DEDROOF6 i ti� �.u..�.rr w'+.—`w.o�.� wY�•�.'r..y` '. '".w.wgw.—wr�in�• �� .. srrwf w. IXPIRESTHREEYEARSFR5M' TEOFAPPROVAt j ,y p.�w.pM�. �' _o�� a^'^'•i ��"' ^''4�' CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYIf) Lam' F02101/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Nicholas Zulkofske FAx Brookhaven Agency,Inc. 631 941-4113 PHONE 631 941-4405 100 Oakland Ave,Ste 1 E-M R , Certificates@_brookhavenagency.com Port Jefferson,NY 11777 INSURERS AFFORDING COVERAGE NAIC# INsuRERA: Southwest Marine&General Insurance Co. INSURED INSURERB; Merchants Preferred Insurance Co. GreenLogic,LLC INSURER C: First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D: National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E: AGCS Marine Insurance Co. INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTRX COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A CLAIMS-MADE X�OCCUR DAMAGE q(RENTED 100,000 X Contractual Liability X X GL202200012922 01/31/2022 01/31/2023 MED EXP(Any oneperson) 5 000 PERSONAL&ADV INJURY $1,000,000 GEN'LAGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY[j]jECOT- LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: E&O Liability $1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1,000,000 B X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08/11/2021 08/11/2022 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE X AUTOS ONLY Ix AUTOS ONLY $ UMBRELLA LIAR OCCUR EACH OCCURRENCE EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N ANY OFFICER/MEMBER ER EXCLUDED?ECUTIVE❑ N/A see separate certificate E.L.EACH ACCIDENT $ (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below 1 E.L.DISEASE-POLICY LIMIT $ C NYS Disability D251202 04/11/2021 04/11/2022 Statutory Limits E Installation Floater/Property SML93076366 04/15/2021 04/15/2022 $300,000 $2,500 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <> ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD vow( Workers' CERTIFICATE OF 5TATE =nsation NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Greenlogic LLC 631-771-5152 97 North Sea Rd.,Suite 3 1c.NYS Unemployment Insurance Employer Registration Number of South Hampton,NY 11968 Insured Work Location'of Ensured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,Le.,a Wrap-Up.Policy) Number 203801194 2.Name and Address of Entity.Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) United Wisconsin Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"I a!' Building Department 53095 Route 25 WC589-00169-021-SZ Southold,NY 11971 3a.Policy effective period 12/01/2021 to 12/61/2022 3d,The Proprietor,Partners or Executive Officers are included.(Only check box if all partnerslofficers included) all excluded orcertain partnerslofficers excluded. This certifies that1he insurance carrier indicated above in box"3"insures the business referenced above in box"1a"for workers' compensation under,the New York State Workers'Compensation Law_(To use this form,New York(NY)must be listed under Item 3 on the INFORMATION PAGE of the workers!compensation insurance policy). The Insurance'Carner or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box°2". The insurance carrier must notify the above.certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums,or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate'is valid for one year after this form 1s approved by the Insurance carrier or its licensed agent,or until the policy expiration date listed in box"3e',whichever is earlier. This certificate is.issued as a matter of information only and confers no rights.upon the certificate.holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it.confer any rights or responsibilities beyond those contained in the. referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon caneellation,of the workers'compensation policy indicated on this form,If the business continues to be named on a permit,license or contract Issued by a certificate holder,the business must provide that certificate holder with a. new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named Insured has the coverage as depicted on this form. Approved by: Alicia Christiansen (P' name of authorized representative or licensed agent of insurance carrier) Approved by: a' 96 1 (Signature) (Dat. Title: Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier:941-306-3077 Please Note:Only Insurance carriers and their licensed agents.are authorized to issue Fort C-106 2.Insurance.b..rokers are NOT authorized to issue it. C406.2(9-17) www.wcb:ny,.gov j1Y'"T0ED'W1tV Workers' CERTIFICATE OF INSURANCE COVERAGE ATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured GREENLOGIC,LLC 631-941-4113 97 NORTH SEA ROAD,SUITE 3 SOUTHAMPTON,NY 1196e 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD BUILDING DEPARTMENT 3b.Policy Number of Entity Listed in Box"1a" 53095 ROUTE 25 DBL251202 SOUTHOLD, NY 11971 3c.Policy effective period 04/11/2021 to 04/10/2023 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described aAWAt ove. Signed Date Si 4/7/2022 gY 9 (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if sox 411,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 111111111 (12-21) 1111111 •`u'k �� .-..'tr?y t:��f y�l, r4,f.�'�'' F _�y^s t''.1.�w.. ut y. / ye..�'< t� ��f'� r � •\, f � ,�'S\.i'�, �+`y,v rvr,;i ,'•.ti •�, s•,,'l k."�; n,cX.,ram-,•�5. .�','�, y::�i� .�"/�,' :t � 1i }';�- .r:�+ f r .v, .v.` µ r � 5 4 i t> �'S� �� '.r':� „i�.•�+" .IEY;�. ; � ..rr.-.� '�':r , !,•{. f�4�f F.r4,, +C r `y,��, n�f. +. I,.,l`�y,,,rr- r£„ •�: �`I�, .ti�N• 'T- ....v-. ,,f� y •:r'+, �� /ti•:t, ..f erg,, 'f ,•.r t.r , < ,H't� .s �(�yy :). fti�f Suffolk County Executive's 0 ce of Consumer Affairs \ Sc IATE ISSUED: i 1 1 No. . I E SUFFOLK COUNTY }yi KHome Improvement Contractor License .yl This is to certifv that MARC A CLEAN doing business as er GREEN LOGIC LLChaving fiunished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules IMPROVEMENT CONTRACTOR,in the County of Suffolk. ( fand regulations of the County of Suff i }_ NOT I! WITHOUTt ll r ' \AND A CURRENT .� / ID CARD Director �?e.� -�> � 1£";'�-.�4,' •'±Sr:,a...4,9�.� ;''3�r_.�. r^,+�;: i- j..- rYi••.+:�,rn�-.�+i. '--r.�F 7�_:..\\ ..r... vr,Qi`>� ;r'1' L y �-..-,,.yr r J:"%»r 3`,''� r"^``'kJ '!� "9. 5 -5'+y*.. Y't-,rr,' Y.� ¢� I'; 5'•i.t.:'.?:} f. }t' .:4 '�,.', ,l'. * ,`:.r'v �.,w �rY.P `•,:�+ .t;..�;.a W.,�.: ,Y4 `yw.r'!• ',',, ' L r �4'r rL .} •;� ,3 r , �- .��, 5� ! J�. •i, , f , �Y, '• '�ti. 4., d�d?*:yN'' y ,� : Yii.� � •h \ ,r'./� fir.:, ''-h"l �f? A: ,,i„7. -d.J� n;.rr�'; 's.'• ^. F.r .r''.^.,.� �. �\: :a !' •r: .:. , . :..+y YiY.: r` t- f.:r'4 ,r iv>y .:�.y �;, '''+,�Kn N'inr."�1?wi..+ •�Kvr� :.,.�. ,\.,;;r u`� /�:.�. y�'n. h ..n ,y,.-r ';�.,,,,c +'r '�-,'''n, w;,.: \_',. `. I Suffolk County Executive's Office of Consumer Affairs t VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 J DATE ISSUED: 12/10/2007 No. 43858-ME SUFFOLK COUNTY .Master Electrician License This is to certify that ROBERT J SKYPALA doing business as GREENLOGIC LLC having given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York. Additional Businesses NOT VALID WITHOUT DEPARTMENTAL SEAL AND.N CURRENT CONSUMER AFFAIRS IP CARD Director EXISTING SERVICE STANDBY AC 120/240, 1 PH, 3W GENERATOR -----PV-SA-1- -------- A AC-COMBINER PANEL NEW EQUIPMENT- 200A KWH ® ® ® AC-CMB-1 ' N • • • 2 1 (PV LOADS ONLY) B f AC DISCONNECT PV-SA-2 A I AC-DSC-2 C ® ® ® (EXTERIOR) . . . 2 1 I BKR-1 i GRID-TIE I LINE TAP MAIN I I D BKR-2 T•� I I ® PV-SA-3 ® ® A i i AC DISCONNECT ATS • ® ® AC-DSC-1 I B ---- B B - -- BKR-3 0 1EGC IEGC PV-SA-4 A ' I I I ® • • • ® ® BKR-4 15A BKR-M I IrQ F PM-1 I i B ---- B El - -- I I , ��MAIN I BKR-5 I I I I JA B N PV-SA-5 ® • • • ® ® N i I I B B B -4 EGC ---- - -- I I I N I I I I I i I I I EGC (TYPICAL SYSTEM SCHEMATIC. ( I FINAL INSTALLATION MAY VARY, I I I I I EXISTING AC PANELI I REQUIRES LOCAL AHJ I I I I ; DISTRIBUTION I EXISTING AND UTILITY APPROVAL) I IRREVERSIBLE BOND, TVP. I EGC 6 CU I� I GEC L/----------L------------J-----#----L- ---------J------- PROPOSED 3-LINE ELECTRICAL DIAGRAM May, Kathleen REVISIONS McDonnell, Matthew ��Sr.S> &GREENLOGICO • ENERGY 400 Pleasant Place 2.) AS-BUILT CONFIGURATION f ELIMINATING THE COST OF ENERGY Southold, NY 11971 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 4 Drawing No: MAY-3LD1 Revision: 2 Revised: 3/26/2023 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 13.60 (PV) TOTAL KW RATING: (DC POWER) 11.17 (PV) QTY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-M425-H-AC 32 PV MODULE: 425 W DC(NOMINAL), EACH SUNPOWER BRAND, MODEL: SPR-M425-H-AC (IQ7AS). 32 PV INVERTER: (INTEGRAL TO MODULE) 349 VA, 1.45 A, 240V AC, EACH NOTE: SUNPOWER MODEL SPR-M425-H-AC INVERTER SETTINGS COMPLY WITH SECTION 7.5.2 AND 7.5.3 OF THE "PSEG LONG ISLAND'S SMART GRID SMALL GENERATOR INTERCONNECTION TECHNICAL REQUIREMENTS AND SCREENING CRITERIA FOR OPERATING IN PARALLEL WITH LIPA'S DISTRIBUTION SYSTEM" May, Kathleen REVISIONS McDonnell, Matthew �" A" G R EEN LOG IC° 1 �O�AS�ST ` � ENERGY 400 Pleasant Place 2.) AS-BUILT CONFIGURATION �'r�OF� yPr ELIMINATING THE COST OF ENERGYSouthold, NY 11971 1.) INITIAL SUBMITTAL WITH APPLICATION N Page 2 of 4 Drawing No: MAY-3LD1 Revision: 2 Revised: 3/26/2023 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-M425-H-AC, 1-CIRCUIT OF 4-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-M425-H-AC, 1-CIRCUIT OF 7-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 7-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-M425-H-AC, 1-CIRCUIT OF 7-MODULES PV-SA-5 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-M425-H-AC, 1-CIRCUIT OF 7-MODULES PM-1 PRODUCTION MONITORING SYSTEM SUNPOWER PVS6, POWER MONITOR AC-CMB-1 AC COMBINER PANEL, CRITICAL LOADS 250V, 100A, NEMA-1, MAIN-LUG, 1-PH, 3-WIRE BKR-1...BKR-5 CIRCUIT BREAKER, PV-SA-1 ... PV-SA-5 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-M CIRCUIT BREAKER, MONITORING SYSTEM MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 25OV, 60A, NEMA-1, FUSED; FUSE RATING: 60A AC-DSC-2 AC DISCONNECT SWITCH (SAFETY SWITCH) 25OV, 60A, NEMA-311, NON-FUSED May Kathleen REVISIONS s ytEsn GR. ° McDonnell, Matthew � E EENLOGIC � ENERGY 400 Pleasant Place t 2.) AS-BUILT CONFIGURATION 0163 ELIMINATING THE COST OF ENERGY Southold, NY 11971 1.) INITIAL SUBMITTAL WITH APPLICATION t �� of Ne Page 3 of 4 Drawing No: MAY-3LD1 Revision: 2 \ Revised: 3/26/2023 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 1,396 WATTS 211-264 VAC 5.8 A AC 240 V,AC — PV-SA-2 2,443 WATTS 211-264 VAC 10.15 A AC 240 V,AC PV-SA-3 2,443 WATTS 211-264 VAC 10.15 A AC 240 V,AC PV-SA-4 2,443 WATTS 211-264 VAC 10.15 A AC 240 V,AC PV-SA-5 2,443 WATTS 211-264 VAC 10.15 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B NMB 6/3 NMB 6 / 6 C NMB 6/3 NMB 6 / 6 D THWN-2 1-1/2" PVC-40 4 / 6 E THWN-2 3/4" EMT 12 / 12 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM May Kathleen REVISIONS 'ESe1i$"�' G R E E IV LOG IC® McDonnell, Matthews A- ENERGY 400 Pleasant Place - r 2.) AS-BUILT CONFIGURATION SlF�z163f3°N ELIMINATING THE COST OF ENERGY Southold, NY 11971 1.) INITIAL SUBMITTAL WITH APPLICATION of N Page 4 of 4 Drawing No: MAY-3LD1 Revision: 2 Revised: 3/26/2023 f M SUN POW ER° 420-44OW Residential AC Module SunPower® Maxeon®Technology Built specifically for use with the SunPower Equinox®system,the only fully integrated solar solution designed,engineered,and warranted by one company. T Highest Power AC Density Available. y The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest efficiency AC solar panel available' Fir E c E m o larger Part of the SunPower Equinox® Solar System • Compatible with Highest Lifetime Energy and Savings mySunPowerIm monitoring Designed to deliver 60% more energy over 25 years in • Seamless aesthetics real-world conditions like partial shade and high temperatures' 150% F - - - - - - - - - - - - - - - - - - 140% - - - - - - - - 130% 120% Up to } 110% 60% 77 100% More 90% Lifetime C ea% Energy 70% Conventional N 60% 0 5 10 15 20 25 Factory-integrated Years of Operation Microinverter Highest-power integrated Best Reliability, Best Warranty AC module in solar With more than 42.6 million and 15 GW modules deployed around • Engineered and calibrated the world, SunPower technology is proven to last.That's why we by SunPower for SunPower stand behind our module and microinverter with the industry's AC modules best 25-year Combined Power and Product Warranty. r Y M-Series: M440 I M435 M430 M425 I M420 SunPower" Residential AC AC Electrical Data Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 Nom.(L-L)Voltage/Range 2 M 240/211-264 208/183-229 Max.Continuous Output Current(Arms) 1.60 1.77 Max.Units per 20 A(L-Q Branch Circuit3 10 9 CEC Weighted Efficiency 97.0% 96.5% Nom.Frequency 60 Hz Extended Frequency Range 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor(adjustable) 0.85(inductive)/0.85(capacitive) DC Power Data Warranties, Certifications, and Compliance SPR-M440- SPR-M435- SPR-M430- SPR-M425- SPR-M420- •25-year limited power warranty H-AC H-AC H-AC H-AC H-AC Warranties .25-year limited product warranty Nom.Powers(Prom)W 440 435 430 425 420 UL 1741/IEEE-1547 Power Tolerance +5/-0% UL 1741 AC Module(Type 2 fire rated) UL 62109-1/IEC 62109-2 Module Efficiency 22.8% 22.5% 22.3% 22.0% 21.7% FCC Part 15 Class B Temp.Coef.(Power) 0.29%/°C ICES-0003 Class B CAN/CSA-C22.2 NO.107.1-01 Shade Tolerance Integrated module-level max.power point tracking CA Rule 21(UL 1741 SA)a (includes Volt/Var and Reactive Power Priority) Certifications •UL Listed PV Rapid Shutdown Equipment6 Tested • • • and Operating Temp. -40'F to+185°F(-40°C to+85°C) Compliance Enables installation in accordance with: NEC 690.6(AC module) Max.Ambient Temp. 122°F(50°q NEC 690.12 Rapid Shutdown(inside and outside the Max.Test Load' Wind:125 psf,6000 Pa,611 kg/m2 back array) Snow:187 psf,9000 Pa,917 kg/m2 front NEC 690.15 AC Connectors,690.33(A)-(Ex1) Max.Design Load Wind:75 psf,3600 Pa,367 kg/m2 back When used with AC module Q Cables and accessories Snow:125 psf,6000 Pa,611 kg/M2 front (UL 6703 and UL 2238)1: Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) •Rated for load break disconnect PID Test 1000 V:IEC 62804 Mechanical Diui Solar Cells 66 Maxeon Gen 6 ConfigurationPackaging Front Glass High-transmission tempered glass with anti-reflective coating Environmental Rating Outdoor rated Modules per pallet 25 Frame Class 1 black anodized(highest AAMA rating) Packaging box dimensions 1915*1072*1220 mm Weight 48 Ibs(21.8 k8) Pallet gross weight 590 kg Recommended Max. Pallets per container 32 Module Spacing 1.3 in.(33 mm) Net weight per container 18,880 kg 73.7 In *Based on datasheet review ofwebsites of top 20 manufacturers per Wood Mackenzie US PV Leaderboard Q3 2021. I (1872 mm]�I FRAME PROFILE 1 Maxeon 435 W,22.5%efficient,compared to a Conventional Panel on same-sized arrays(260 W,16%efficient , approx.1.6 m2),7.9%more energy per watt(based on PVSyst pan files for avg.US climate),0.5%/yr slower 1 degradation rate(Jordan,et.al."Robust PV Degradation Methodology and Application"PVSC 2018). Grounding Holes 3 2 Voltage range can be extended beyond nominal if required by the utility. g 3 Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. G' E 4 Factory set to IEEE 1547a-2014 default settings.CA Rule 21 default settings profile set during commissioning. $ c ❑ 5 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25°Q.All DC voltage is fully contained within the module. (A)Long Side:1.3 In(32 mm) 6 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12;and C22.1-2015 Rule 64-218 Rapid I Short Side:0.9 in(24mm) Shutdown of PV Systems,for AC and DC conductors;when installed according to manufacturers instructions. 1 7 Please read the safety and installation Instructions for more information regarding load ratings and mounting configurations. Please read the safety and Installation Instructions for details. See www.sunpower.com/company for more reference Information. Specifications included in this datasheet are subject to change without notice. m 02021 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,SUNPOWER EQUINOX 539973 Rev B/LTREN and MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the U.S.MAXEON is ap 6oiu• _ registered trademark of Maxeon Solar Technologies,Ltd.For more information visitwww.maxeon.com/legal. M.d°I.Fi.P.arorm..u:Ty"2 Publication Date:October2021 1-800-SUNPOWER sunpower.com t ResidentialMounting System Simple and Fast Installation • Integrated module-to-rail grounding Pre-assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates consistent,even - module spacing == • Simple,pre-drilled rail splice UL 2703 Listed integrated grounding Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management Customer-Preferred Aesthetics " #1 module and#1 mounting aesthetics • Best-in-class system aesthetics Elegant Simplicity Premium,low-profile design Black anodized components SunPower® InvisiMountTm is a SunPower-designed Hidden mid clamps and end clamps rail-based mounting system.The InvisiMount system and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility,and superior aesthetics. Built for use with SunPower DC and AC modules The InvisiMount product was specifically envisioned and • Best-in-class system reliability and aesthetics • Combine with SunPower modules and engineered to pair with SunPower modules.The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. - IllJlll r sunpower.com s m he x _ a tTM SunPower InvislMoun Residential Mounting System IMSIMOUnt Component Module*/Mid Clamp and Rail Module*/End Clamp and Rail Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly End Cap t DetailsInvisiMount Component Component Material Weight Temperature -40*C to 90°C(-40°F to 194°F) Max.Load(LRFD) 3000 Pa uplift Mid Clamp Black oxide stainless steel AISI 304 63 g(2.2 oz) 6000 Pa downforce End Clamp Black anodized aluminum alloy 6063-T6 110 g(3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m(9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m(9 oz/ft) 25-year product warranty Ground Lug 304 stainless Warranties Assembly (A2-70 bolt;tin-plated copper lug) 106.5 g/m(3.75 oz) 5 year finish warranty End Cap Black acetal(POM)copolymer 10.4 g(0.37 oz) • UL 2703 Listed Certifications Roof Attachment Hardware Supported Class A Fire Rated InvisiMount System Design •• Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturer's documentation. *Module frame that is compatible with the InvisiMount system required for hardware interoperability. O 2015 SunPower Corporation.All Rights Reserved. SUNPOWER,the SUNPOWER logo,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation.All other trademarks are the property of their respective owners. sunpower.com Specifications included in this datasheet are subject to change without notice. Document#509506 RevC w _ Improve Support, Reduce Maintenance Costs SunPower EnergyLink—Plug-and-Play Installation An intuitive monitoring website enables you to: This complete solution for residential and commercial monitoring and See a visual map of customer sites control includes the SunPower®PV Supervisor 6(PVS6)which improves Remotely manage hundreds of sites the installation process,overall system reliability,and customer Receive elective system reports experience. Locate system issues and remotely diagnose Compact footprint for improved aesthetics Diagnose issues online Robust cloud connectivity and comprehensive local connectivity Drill down for the status of individual devices Flexible configuration of devices during installation Consumption metering - - -- Revenue-grade production metering(pending) Web-based commissioning Remote diagnostics of PVS6 and inverters IIIIII�NIIIIIIfIIIII _ Durable ULType 3R enclosure reduces maintenance costs Easy integration with SunPower eBOS Add Value for Customers Robust Cloud Connectivity With the SunPower Monitoring System c, )WE,� Multiple options to maintain optimal customers can: See what their solar system produces each connectivity: day,month,or year Hardwired Ethernet Optimize their solar investment and save on Wi-Fi energy expenses Cellular backup See their energy use and estimated bill savings See their solar system's performance using the SunPower monitoring website or mobile app Datasheet S U N P WE R" 40 SunPower" Er�ergyLnV` Residential and Commercial PVS6 SunPower Monitoring Websltes PVS6 SunPower AC Modules d Multiple communication options include Ethernet,Wi-Fi,and cellular. RequirementsSite Operating Conclitioris Number of SunPower AC modules 85 Temperature -22°F to+1401F(-30°C to+60°C) supported per PVS6 Humidity(maximum) 95%,non-condensing High-speed Internet accessvla accessible Internet access router or switch Power • 100-240 VAC(L-N),50 or 60 Hz 208 VAC(L-L in 3-phase),60 Hz Communication RS-485 Inverters and meters • One channel of revenue-grade production metering Integrated Metering . Two channels of consumption metering Weight 5.5 Ibs(2.5 kg) Ethernet 1 LAN(or optional WAN)port Dimensions 11.8 x 8.0 x 4.2 in.(30.5 x 20.5 x 10.8 cm) PLC PLC for SunPower AC modules Enclosure rating UL50E Type 3R WI-FI 802.11 b/g/n 2.4 GHz and 5 GHz Cellular LTE Cat-M1/3G UMTS Web and Mobile Device Support ZlgBee IEEE 802.15.4 MAC,2.4GHz ISM band Data Storage 60 days Customer site monitor-us.sunnower.com Upgrades Automatic firmware upgrades Partner site py�mgmt.us.sunpower.com Browsers Firefox,Safari,and Chrome Mobile devices iPhone•,iPad•,and Android' Customer app 1.Create account online at:monitor.us.sun Warranty and Certifications 2.On a mobile device,download the SunPower Monitoring Warranty 10-year Limited Warranty app from Apple App Stores"^or Google PlaytIstore. 3.Sign in using account email and password. Certifications UL,cUL,CE,UL 61010-1 and-2,FCC Part 15(Class B) c FCc O11111111 ut>Ro FCC ID:YAW529027 E503346 • ,WER u s ------------- NEW EQUIPMENT------------------------ EXISTING SERVICE PV—SA-1 A AC—COMBINER PANEL 120/240, 1 PH, 3W Fan AC—CMB-1 B N • • • 2 1 (PV LOADS ONLY) I 200A KWH I PV—SA-2FM En A . . . I A I C � AC—DS1C-1 , BKR—i AC DISCONNECT i I i BKR-2 ' PV—SA-3 N . • • t li — BKR-3 r � I J ' MAIN ---- I BKR-4 FUSED � A B N PV—SA-4 �� III I , ® ' N " ' 2 1 i t N III IEGC — — N TYPICAL PV MODULE WITH I I13 INTEGRAL DC/AC INVERTER ( III EGC IIII I EGC IIII I I I I ' IIII I I EXISTING AC PANgLGECSTING I I LLJi-----------1- GEC ——————— 13.600kW DC 12.288kW AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS May, Kathleen &McDonnell, Matthew G R E E N LOGIC" 400 Pleasant Place ENERGY Southold, NY 11971 1.) INITIAL SUBMITTAL WITH APPLICATION ELIMINATING THE COST OF ENERGY Page 1 of 3 Drawing No: Pleasant-3LD1 Revision: 1 Revised: 6/20/22 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-M-425-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-2 PV SUB-ARRAY SPR-M-425-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-3 PV SUB-ARRAY SPR-M-425-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-4 PV SUB-ARRAY SPR-M-425-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3400 WATTS 211-264 VAC 13.82 A AC 240 V, AC PV-SA-2 3400 WATTS 211-264 VAC 13.82 A AC 240 V,AC PV-SA-3 3400 WATTS 211-264 VAC 13.82 A AC 240 V, AC PV-SA-4 3400 WATTS 211-264 VAC 13.82A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS May, Kathleen & GREENLOGIC® McDonnell, Matthew 400 Pleasant Place ENERG`r Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 3 Drawing No: Pleasant-3LD1 Revision: 1 Revised: 6/20/22 s - EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V, 200A, NEMA-1, 1-.PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 100A, NEMA-1, FUSED; FUSE RATING: 100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 4 / 6 C THWN-2 2" EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS May, Kathleen & McDonnell, Matthew G EENLOGIC 400 Pleasant Place ENERGY Southold NY 11971 ELIMINATING THE COST.OF ENERGY � 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Pleasant-3LD1 Revision: 1 Revised: 6/20/22 J AMEdS J. S TOUT A R C H I T E C T & Assoc . 2 G R E G L A N E E AST NO R T H P 0R TN. Y. 631 — 8 58 9368 Certification Letter June 24, 2022 JUL 0 B 2n92 May-McDonnell Residence BUILDING DEPT 400 Pleasant Place TOWN OF SOUTHOLD Southold, NY 11971 To the Whom it May Concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at 400 Pleasant Place, Southold and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and complies with the 130-mph wind design load as per the 2020 Residential code of NYS (RCNYS), the Long Island Unified Solar Permit Initiative(LIUSPI),and the ASCE 7-16. The existing 2"x 10" @ 16"o.c. rafters will provide adequate support. The existing 2"x 8"@ 16"o.c. rafters will provide adequate support. Thank you for your understanding in this matter. APPP VED AS NO ED/ DATE: B.P.# James J. Stout COIARLY WITF ALL [jFS OF FEE: BY:' NEW RK ST80 E & TOWN CODES NOTIFY. BUILDING DEPARTMENT AT AS REQUIRED D CONDITIONS OF 765-1802: :8AM TO 4 PM FOR THE FOLLOWING'.INSPECT IONS: ZSA 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 0U fH',)LD TOWN PLA BOAR p AR 2. ROUGH-.--, FRAMING & PLUMBING �� C,S, 3. INSULATION STEES 5S J S7-0 j�n 4. FINAL, CONSTRUCTION MUST � BE COMPLETE FOR C.O. ALL,CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR cS�\ ; 0 t 3 0�� DESIGN OR CONSTRUCTION ERRORS. 1 � 0 . C PA . C Y OR US EIDS'U _ WFUL !ELECTRICAL �NI CERT,IFICAT" INSPECTION REQUIRE® d'(5L on n c-- m u 5 - 6 - �o ca-k-d o r t eas ��,h� GREENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#A: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Azimuth:198" Pitch:42' Monitoring System: N SunPower Pand/ArTy Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:36'X 6'10" Surface:3T 6"X 12'9" Magic#:invisimount Legend: ® 7 SunPower 425W Panels SunPower Invisimount Rail • 25 UniRac Drk Standoff B 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Ll Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf En 'neer/Architect Seal: �SX�RED ARc r ,PEES J S TpG y Ijfn `A t1 N ON Drawn By:MA .—wiing#1 of 17 Date:6/22/2022 REV:A Drawing Scale:3/16"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#A: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Azimuth:198" Pitch:42° Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" ' . 1-1 'D' < Array:36'X 6'10" Surface:3T 6"X 12'9" Magic#:Invisimount Legend: ® 7 SunPower 425W Panels SunPower Invisimount Rail • 25 UniRac Drk Standoff WaDouglas.Pir Rafter 167 0.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal, CARED aR� �5 DES J s To 'X 21633 0 . 4C)F NON�l Drawn By:MY 'Draw"mg##2 of 17 Date:6/22/2022 1 REV:A Drawing Scale:3/16"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#A: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Azimuth:198" Pitch:42" , Monitoring System: SunPower ep Pand/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" 1 1 Array:36'X 6'10" Surface:3T 6"X 12'9" Magic#:Invisimount Legend: 1 1 ® 7 SunPower 425W Panels SunPower Invisimount Rail • 25 UnRac Drk Standoff 18 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof-Surface:4 Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: D ARCh/ 0 TC F N�� Drawn By:MA Drawing#3 of 17 Date:6/22/2022 REV:A Drawing Scale:3/16"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#B: Total System Size:13.600kW Array Size:1.700kW 1 circuit of 4 on a 20A breaker Avmuth:198' Pitch:45" Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:12'41/8"X 6'10" Surface:1 V 3"X 10' >< >< Magic#:Invisimount Legend: ® 4 SunPower 425W Panels SunPower Invisimount Rail • 14 UniRac Drk Standoff 18 2x8 Douglas Fir Rafter 16"O.C. 7- =770 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ED ARC, ,PEES J S� TOGY J�C' 02 33 Drawn By:MA Drawing#4 of 17 Date:6/22/2022 REV.A Drawing Scale:1/4"=1.9 GREENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#B: Total System Size:13.600kW Array Size:1.700kW 1 circuit of 4 on a 20A breaker Azimuth:198" Pitch:45" Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:12'41/8"X 6'10" Surface:19 3"X 1U Magic#:Invisimount Legend: ® 4 SunPower 425W Panels SunPowerinvisimount Rail • 14 UniRac Drk Standoff 8 W Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 Psf Engineer/Architect Seal: :D'ARCti S)-D Ci'x ���A v ve (S 1 O/1_ NO Drawn By:MA Drawing#5 of 17 Date:6/22/2022 REV:A Drawing Scale:1/4"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#B: Total System Size:13.600kW Array Size:1.700kW 1 circuit of 4 on a 20A breaker Azimuth:198' Pitch:45" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-M425 H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:12'4 1/8"X 6'10" 2 Surface:19 3"X 10' Magic#:Invisimount d egertd: ® 4 SunPower425W Panels SunPower Invisimount Rail 2 • 14 UniRac Drk Standoff f l W Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31psf Engineer/Architect Seal: 11\��ED ARCy �5 DES J /9T 0 gg3 yOQ_ OF NE`N Drawn By:MA Drawing#6 of 17 Date:6/22/2022 REV:A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#C: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker A2jmuth:108° Pitch:33' Monitoring System: Z SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:13'8 5/8"X 12'4 1/8" Surface:21'3"X 19 2" Magic#:Invisimount Legend: ® 7 SunPower425W Panels SunPower Invisimount Rail • 14 UniRac Drk Standoff 8 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ��RED A& 5 S J S P T C) 3Y'tt M\tltl ! T . y OF NE�y Drawn By:MA Drawing#7 of 17 Date:6/22/2022 REV:A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#C: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Azimuth:108° Pitch:33° Monitoring System: Z SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:13'8 5/8"X 12'41/8" Surface:21'3"X 19'2" Magic#.Invisimount IN Legend: ® 7 SunPower 425W Panels — SunPower Invisimount Rail • 14 UniRac Drk Standoff 1 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31psf Engineer/Architect Seal: D ARC 5 SJ ST OAT ! JT F N�� Drawn By:MA Drawing#8 of 17 Date:6/22/2022 REV:A Drawing Scale:1/4"=l ff GREENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#C: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Aamuth:108" Pitch:33° Monitoring System: Z SunPower 3 Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:13'8 5/8"X 12'41/8" Surface:21'3"X 19'2" Magic#:Invisimount ZL Legend: ® 7 SunPower 425W Panels — SunPower Invisimount Rail 3 • 14 UniRac Drk Standoff f B 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ��RED ARc�, ��5 ��-'S J S T oU sa d 1 t'6Y9`.�•• ' 021633 Q� O NE�� Drawn By.MA Dra~iin ing#FTb—f7 7 Date:6/22/2022 REV:A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#D: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Azimuth:108° Pitch:44" Monitoring System: Z X iX SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Raddng:SunPower Invisimount Panel:73.7"X 40.6" Array:24'3/4"X 6'1 3/4" Surface:28'2"X 18'2" Magic#:Invisimount Legend: ® 8 SunPower 425W Panels SunPower Invisimount Rail • 12 UniRac Drk Standoff 6 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf En ineer/Architect Seal: ARC DES J S r / P OAT 1633 O� Drawn By:M Drawing#10 of 17 Date:6/22/2022 REV:A Drawing Scale:1/4"=1.0' GR ENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#D: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Azimuth:108" Pitch:44° Monitoring System: e SunPower Pand/Array Specifications: Panel:SPR-M425-H-AC Raddng:SunPower Invisimount Panel:73.7"X 40.6" Array:24'3/4"X 6'1 3/4" Surface:28'2"X 16 2" Magic#:Invisimount Legend: ® 8 SunPower 425W Panels SunPower Invisimount Rail • 12 UniRac Drk Stardoff 2x10 Douglas.-Par Rafter 16"aQ Notes: Number of Roof Myers:1 Height above Roof Surface:4" _ Materials Used:UniRac,SunPower Added Roof load of PV System:2.31psf I lr Engineer/Architect Seal: �<�?,ED ARc TC i k `tvv a OF NE' Drawn By:MA Drawing#11 of 17 Date:6/22/2022 REV:A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#D: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Azimuth:108° Pitch:44° A\ Monitoring System: z SunPower 4 Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:24'3/4"X 6'1 314" Surface:28'2"X 18'2" Magic#:Invisimount Legend: ® 8 SunPower 425W Panels SunPower Invisimount Rail 0 12 UniRac Drk Standoff f 8 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: ���ED ARc CO ESJST ' ve OCj-- �\%l "i-ravu�� . Drawn By'O �—._Ding#12 of 17 Date:6/22/2022 1 REV:A Drawing Scale:1/4"=1.0' GREENLOGIC® ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#E: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Azimuth:288" Pitch:44" Monitoring System: Z SunPower Pand/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:24'3/4"X 6'1 3/4" Surface:28'2"X 19 2" Magic#.Invisimount Legend: ® 7 SunPower425W Panels SunPower Invisimount Rail • 12 UniRac Drk Standoff 18 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31psf Engineer/Architect Seal: -CJa:j,E ARC s Drawn By: in 3 of 17 Date:612212022, -REVTA Drawing Scale:1/4"=1.0' GREENLOGIC® ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#E: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Azimuth:288" Pitch:44° Z Monitoring System: SunPower Panel/ArraySpecifications: Panel:SPR-M425-H-AC Raddng:SunPowerinvisimount Panel:73.7"X 40.6" Array:24'3/4"X 6'1 3/4" Surface:28'2"X 1V 2" Magic#:Invisimount Legend: ® 7 SunPower 425W Panels SunPower Invisimount Rail • 12 UniRac Drk Standoff 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Sea]: ED A[ c \5 S J S T 9 (j) ` �c 1633 \ OF NE`� Drawn By:MA Drawing#14 of 17 Date:6/22/2022 REV.A Drawing Scale:1/4"=1.0' GREENLOGIC° ENERGY GreenLogic,LLC Approved May,Kathleen and McDonnell,Matthew 400 Pleasant Place Southold,NY 11971 Surface#E: Total System Size:13.600kW Array Size:2.975kW 1 circuit of 7 on a 20A breaker Aamuth:288° Pitch:44° Z Monitoring System: SunPower 5 Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:24'3/4"X 6'1 3/4" Surface:28'2"X 18'2" IV \V IF Magic#:Invisimount Legend: ® 7 SunPower 425W Panels SunPower Invisimount Rail 12 UniRac Drk Standoff B 2x10 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:UniRac,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: �,, FtED AR„y r \ A�'r-S J S TC� V �C"` ��qTF 021 3 N EIN Drawn By:MA Drawing#15 of 17 Date:6/22I2022 REV:A Drawing Scale: 1/4"=1.0' No Vent Pipes Will Be Covered By The Solar Array G�GREENLOGIC® ENERGY Legend: GneenLogic,LLC Approved May,Kathleen and McDonnell,Matthew AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 400 Pleasant Place per R202 definitions per R324.6.1 as per R324.6.2.1 Southold,NY 11971 Total System Size:13.600kW 1 circuit of 7 on a 20A breaker 1 circuit of 4 on a 20A breaker 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker Meter Azimuth:198' Monitoring System: N SunPower 7 SunPower PandlArray Specifications: 425W Panels Panel:SPR-M425-H-AC 7 SunPower Racking:SunPowerinvisimount 425W Panels Panel:73.7"X 40.6" Surface:89'6"X 58' Magic*Invisimount I Legend: 0 32 SunPower 425W Panels SunPower Invisimount Rail -- -- APJ I I ra • 77 UniRac Drk Standoff C cc ¢ 00 WO Douglas Fir Rafter 16"O.C. N 1 1 00 2x8 Douglas Fir Rafter 16"O.C. I IAPI Notes: I I Number of Roof Layers:1 ——————————————— I Height above Roof Surface:4" Materials Used:UniRac,SunPower ——— I Added Roof load of PV System:2.31 psf Engineer/Architect Seal: Fi �ED A RC' ;f � STOG� T�C� -- ---� I V 7 SunPower <!� 425W Panels 4 SunPower 425W Panels 4 7 SunPower 425W Panels - Drawn By:MA Drawing#16 of 17 Date:6/22/2022 REV:A Drawing Scale:1/16"=1.0' GREENLOGIC® ENERGY JOB MATERIAL LIST GreenLogic,LLC Approved i May,Kathleen and McDonnell,Matthew -------- 400 Pleasant Place ------ Southold,NY 11971 Total System Size:13.600WV 1 ci rcuit of 7 on a 20A breaker 1 circuit of 4 on a 20A breaker 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker Qt Material List V. Rail Material List Qtv. I circuit of 7 on a 20A breaker ------ Azimuth:198* Uni Rac 4!'Drk Stan doffs i 77 Monitoring System: SunPower 5/16"x4.5"SS Lag Bolts i 154 Panel/Array Specifications: 5/16"Stainless Steel Washers 154 -J, Panel:SPR-M425-H-AC Oatey 12920 Flashing(Black) 65 Racking:SunPower Invisimount. Oatey 12920 Flashing(Silver) 12 Panel:73.7"X 40.6- Surface: Magic*Invisimount Legend: Ml 32 SunPower 425W Panels ------------------ ------- -------- SunPower Invisimount Rail ------ ........... 0 77 UniRac Drk Standoff 00 2x1 0 Douglas Fir Rafter 16"O.C. go 2x8 Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:i Height above Roof Surface:4�' Materials Used:UniRaq SunPower Added Roof load of PV System:2.31 psf Engineer/Architept Seal: QED ARC J S)-00 CA 0 N'33 0 Drawn By:MA Drawing#17 of 17 Date:6/22/2022 REV:A Drawing Scale:1/16"=1.0'