HomeMy WebLinkAbout50382-Z o01gtlFFO(�-�pG Town of Southold 5/31/2024
P.O.Box 1179
C.
o _ 53095 Main Rd
yfj0l �ao ;r Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 45239 Date: 5/31/2024
THIS CERTIFIES that the building GENERATOR
Location of Property: 14995 Oregon Rd, Cutchogue
SCTM#: 473889 Sec/Block/Lot: 73.-1-2.2
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
1/26/2024 pursuant to which Building Permit No. 50382 dated 2/29/2024
was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
accessory generator as applied for(by accessory garage).
The certificate is issued to Olsen Family 2020 Trt
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 50382 4/8/2024
PLUMBERS CERTIFICATION DATED
th riz d ignature
��o�SyFFoi,t TOWN OF SOUTHOLD
BUILDING DEPARTMENT
y, TOWN CLERK'S OFFICE
• SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit #: 50382 Date: 2/29/2024
Permission is hereby granted to:
Olsen Family 2020 Trt
149 Brewster Rd
Massapequa, NY 11758
To: install generator as applied for (accessory garage).
At premises located at:
14995 Oregon Rd, Cutchogue
SCTM #473889
Sec/Block/Lot# 73.-1-2.2
Pursuant to application dated 1/26/2024 and approved by the Building Inspector.
To expire on 8/30/2025.
Fees:
ACCESSORY $125.00
ELECTRIC $100.00
CERTIFICATE OF OCCUPANCY $100.00
Total: $325.00
Building Inspector
pF SOUl��l
� o
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 G Q
• �o Southold,NY 1197]-0959 sean.devlin(&-town.south old.ny.us
�Q
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Olsen Family 2020 Trust
Address: 14995 Oregon Rd city:Cutchogue st: NY zip: 11935
Building Permit#: 50382 Section: 73 Block: 1 Lot: 2.2
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: Electrician: G&S Electric License No: 578ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Service
Commerical Outdoor X 1st Floor Pool
New X Renovation 2nd Floor Garage X
Addition Survey Attic Generator X
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO
Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors
Disconnect Switches 4'LED Exit Fixtures Sump Pump
Other Equipment: 18kW Generac Generator w/200A Transfer Switch
Notes: Generator
Inspector Signature: '- Date: April 8, 2024
S.Devlin-Cert Electrical Compliance Form
OF 80UT9p�
# * TOWN OF SOUTHOLD BUILDING DEPT.
`ycourm 631-765-1802
v INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] SULATION/CAULKING
[ ] FRAMING /STRAPPING [ FINAL bey
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] .FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE O [ ] RENTAL
REMARKS: i tCi
DATE INSPECTOR
FIELD INSPECTION REPORT DATE COMMENTS
ro
FOUNDATION (1ST) — -- --- -- — w
--------------------------------------
FOUNDATION (2ND) ----- —
Z
O
ROUGH FRAMING& — -
PLUMBING —
INSULATION PER N.Y. --- "3
STATE ENERGY CODE
S
FINAL
ADDITIONAL COMMENTS
r
y ��la E�e�ck�c Ce � cn► — o
9-1
o
=�gUFFO[K�OGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT
y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownnygov
Date Received
APPLICATION FOR BUILDING PERMIT
V-- Builcling
For Office Use OnlyPERMIT NO. Inspector: J 2 5
A N 2024
'Applications and forms must be filled out in their entirety.,Incomplete
applications will not be accepted- Where the Applicant is not the owner,an s¢�IlcfEr� °pa en
Owner's Authorization form(Page 2)shall be completed. _ Town of Southold
Date: �f a
F OWNER(S) PRO RTY: -
Name: SCTM#1000-
Project Address:
Phone# V _la---_ �' Email:---
Mailing Address: r-
__--------------- -- ---- --�- - -/�c-Grr-sue--- - --- - - - -�- - - - - - - -� - - - -- --I -- ems'-----
CONTACT=PERSON:'
Name:
Mailing Address:
Phone#: S—l6_._�' �-__------------- Email:_-� ---------
DESIGN PROFESSIONAL INFORMATION:
Name:
Mailing Address:
Phone#: I
CONTRACTOR INFORMATION: '
Name: --
// dMailing A _.ess:.__�_. A4 _6-.'" ..C-----•-- ----�.. _ .-- -3�-------------_.__--__
Phone#: ail:Em
eom/S-rsu e. _- ---
DESCRIPTION'OF PROPOSED CONSTRUCTION
❑New Structure ❑Addi ion ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
tt--her% D C b1 , $
Will the lot be re-graded? ❑Yes XNo Will excess fill be removed from premises? Dyes ANO
1 I
PROPERTY INFORMATION
Existing use of property: Intended use of property:
Zone.or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? Dyes ONO IF YES, PROVIDE A COPY_`_
�Check Box After Reading:_ The owner/contractor/design professional is responsible for all drainage and storm'water issues as provided by.
pter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition'as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
-housing code and'regulatiohs and to admit authorized inspectors on premises and in building(s)'for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name): (Authorized Agent ❑Owner
Signature of Applicant: Date_STATE OF OF NEW YORK)
SS:
COUNTY OF 511 r-P6 4-
✓�)
ter L�/UL� /�7 URrS- being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the �d-CN 1(!QA;r". C-7_A<
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of ,20
Notary Public
PROPERTY OWNER AUTHORIZATION
(Where the applicant is not the owner)
residing at T7- /'cC
do hereby authorize L=. �(4,6ye-- ,L7 wg c-cff to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
�1 Owner's Signature Date
y L3D RA4 DL.S a Al
Print Owner's Name
2
o�oS�FFp��C' BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
o =` Town Hall Annex- 54375 Main Road - PO Box 1179
e ^ Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
Ia mesh CaD-southoldtownny.gov - seanda-southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 1/25/24
Company Name: G & S Electrical
Electrician's Name: Bob Guariello
License No.: 31568-ME Elec. email: gs1641 @aol.com
Elec. Phone No: 631-765-1641 ❑✓ I request an email copy of Certificate of Compliance
Elec. Address.: 250 Budd's Pond Road, Southold, NY 1,1971
JOB SITE INFORMATION (All Information Required)
Name: Olson Family 2020 Trust
Address: 14995 Oregon Road, Cutchogue, NY 11935
Cross Street: Bridge Lane
Phone No.: 516-695-0583
Bldg.Permit#: r���a email: dolson43@aol.com
Tax Map District: 1000 Section: 73• Block: -1 Lot: -2.2
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Generator
Square Footage:
Circle All That Apply:
Is job ready for inspection?: YES ❑ NO ❑Rough In Final
Do you need a Temp Certificate?: ❑ YES NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter#
❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Recon'nect❑Underground❑Overhead
# Underground Laterals 1 R2 H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
BUILDING DEPARTMENT- Electrical Inspector
��O Gy.► TOWN OF SOUTHOLD
Town Hall Annex - 54375 Main Road - PO Box 1179
*► Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
jamesh southoidtownny.gov — sea ndCcrD_southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 1/25/24
Company Name: G & S Electrical
Electrician's Name: Bob Guariello
License No.: 31568-ME Elec. email: gs1641 @aol.com
Elec. Phone No: 631-765-1641 ❑✓ I request an email copy of Certificate of Compliance
Elec. Address.: 250 Budd's Pond Road, Southold, NY 11971
JOB SITE INFORMATION (All Information Required)
Name: Olson Family 2020 Trust
Address: 14995 Oregon Road, Cutchogue, NY 11935
Cross Street: Bridge Lane
Phone No.: 516-695-0583
Bldg.Permit#: F-LD- email: dolson43@aol.com
Tax Map District: 1000 Section:73• Block: -1 Lot: -2.2
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Generator
11 2d Square Footage:
Circle All That Apply:
Is job ready for inspection?: ✓❑ YES ❑ NO ❑Rough In W Final
Do you need a Temp Certificate?: ❑ YES ✓0 NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 0 1 2 H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
SURVEY OF CERRFIED TO.DEBORAHOLSON
WAYNEOLSON
DESCRIBED PROPERTY
LONG ISLAND SOUND SITUAOFS TE AT
CUTCHOGUE
N6728, SUFFOIKCO MYUNEWYORK JOBNO.:2=-196
2B.6T ^m, SCT.M DIST.f003 SEC.73 BLK 1 LOT22 MAPNO..,25 5p g15p�� �7g FILED:
25 13 0 SL'A<E 1,-50' 75 f00 DATE:DECEMBER2,207P 200 225 LOC/FOUNDARON:fMM
\ AS$UILTSURVEY.'1624l23
1 \I LOTAREA:581,596SD.FT.-M MACRES
\ SANTARYLOCARONOIMENSIONS p.�EOF NEly pp
MAINDWELLING GARAGE S�p?�'•�W
COASTAL�1 \asp. CORNERA 27� � CORNER 42 52'
H Q ll CORNERS 31' 5P CORNER 19' 38,
-�yNDARY sm p�
LAMA
\N
1 04g
z m c TS
C 9
S. t N f �$ JEFFREYW..HAVERERLS
\ m9 Ai LCENSEN0:050538
g � r
TwFam-
LAND SURVEYING
18HAMPTONBAAYS,UK I
M MY YOPX 11946
1 s M 631-369-8312-(F)631-3694313
ema2'nfiNNrislandsNrve hoN.ronT
\ COMESOFRB4SURVEYM49 EIM MPAPEROR ELECIROMA NOTBWM
MELANDSURVEYORSPN(ED SEAL OR MWS6EDSFJLL SHALL NOT BE
q COWDERED TO BEA VAUDCOPYAND MALL NOTBEUSMFORANYPURPOSE
cASTLE HILL ROAD-- DIGITAL RELEASE
N \ \
13.65 tuA6 N 5123'30'E �' N 1 .
�NUPO6?EMPEPLlxE Matl
N 31"2E20•E
T E R,f36
ei
YfE
11�E
1
1 1 'M.taTE
'PN fAE
aee
y ,
1
\
93
1
1%Z
M
1F
hL
F\
\I
� C
N p
Z m mp
a
T
T
S9 L
99
i {
A� yg5 $g
O
N qq
L 4`1
M
\1
T2H'
\ 124.101
W\�•6���.�. 64<g10 �4G
'i. �j pyitlE
1
,�S�
138
m /••i� y 243.85
Jxe
_ �J
1 N �• 4 81' 6y6EOPPAVENen Q
i S12p"W
m
IIM � f13P �6A4M / EWEOPPAYENBA oREGON ROAD
L:63.T are
Z
m
LOTAREATOMETE38BOUNDSASSHOY1N:581,WOSD.FT:-fa352ACM
ELEVA'ON", ONREFER 70
NA.'.
APP 0 EO AS NOTED
DAM• .R# ao
FEE �bb BY
NOTIFY BUILDING DEPARTMENT AT
631 765-1802 8AM TO 4PM FOR THE
FOLLOWING INSPECTIONS:
1. FOUNDATION-TWO REQUIRED
FOR POURED CONCRETE
2. ROUGH-FRAMING&PLUM,91I,►G
3. INSULATION
4. FINAL-CONSTRUCTION MUST
BE COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL_ MEET THE
REQUIREMENTS OF THE CODES 0�'NEV-J
YORK STATE. NOT RESPOi,0,13LE FOR
DESIGN OR CONSTRUCTON ERRORS
COMPLY WITH ALL CODES OF
NEW YORK STATE &TOWN CODES
AS REQUIRED AND CO DITIONS OF
SOUTHOLD rOWIN
SOUTHO
N ZBA
PLAN NING BOARD
SOUTH TOWN TRUSTEES
HPC
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICAT"
OF OCCUPANCY
ELECTRICAL
INSPECTION REQUIRED
-GUARDIAN® _SERIES
10/14 8 k _.
.
Residential:Standby G-enerators•. :
Air=Cooled Gas•Engine
. ,
INCLUDES:. . Standby Fower:Ratin9
Go07171-0;Gb07112-0(Aluminum--Bisque)--10 kW 60 Hz
• .True PowerT" Electrical Technology G007223-10,.G007224-10,G007225-10(Aluminum=Bisque).-14 kW 60 Hz
• Two-line multilingual digital LCD Evolution"' controller G007226-10,G007228-10.(Aluminum-Bisque)-1a kW,fiO Hz
(English/Span ish/French/Portug uese)-
• Two transfer switch options available:
1 QO amp 16-circuit switch or ,
.ROO amp.service rated smart switch
•. - Electronic-goyerrtor, .�1 ..
• Standard Wi-Fi(P connectivity
• System status&maintenance interval LED indicators
• .Sound attenuated enclosure.
GENE�RAC' — .
Flexible-fuel line connector
• .-Natural gas or.LP.gas operation. r
• 5 Year limited warranty.
0 Listed and.labeled'for installation as close as 18 in.457. ' - i
( Product shown with.oplional fascia kit' - -
mrri).to a structure.*. '
*Must be located.away from doors, windows, and'fresh or C UL US
air.intakes and in accordance with loca/.codes. . ET1/.us O QUA .
.
. LISTED . .
Note:CUL or CUL certification only applies fo unbundled units and'units packaged with limited
circuit switches.Units packaged with'the Smart Switch are ErL or UL certified in the USA only.;
FEATURES
O. INNOVATIVE ENGINE DESIGN-&. RIGOROUS. TESTING are at the'heart of. O'. SOLID-STATE, FREQUENCY.COMPENSATED VOLTAGE REGULATION:.This'.i
Generac's success in providing the most reliable-generators possible.Generac's G- state-of=the-art.power.maximizing regulation System is'•-standard:on all Generac
Force engine_lineup offers added peace of mind.and.reliability for when you need,it . . .models.-It provides optimized FAST RESPONSE to,changing.load.conditions'and - .
the most.The.G-Force series engines are purpose builtaod designed to.handle the MAXIMUM-MOTOR STARTING CAPABILITY by,electronically.torque-matching.the
rigors of extended run times in,high temperatures and extreme operating conditions. . surge loads to the engine.Digital.voltage regulation,at-4-1
-O TRUE POWER-ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave -O SINGLE SOURCE SERVICE RESPONSE from.Generac'•s exte.ns,ive.dealer.network
form produce less than 5%Total Harmonic-Distortion for utility quality power.This. provides-parts and service know-how-for the 6ritire unit, from the,`engin.e to the..
allows confident operation of sensitive electronic equipment and micro-chip based .-.smallest electronic com_ponent..
appliances,such as variable speed HVAC systems.
O. TEST CRITERIA: O. GENERAL.TRANSFER SWITCHES:.Long'life'and reliability are synonymous with
✓ PROTOTYPE TESTED, ✓ NEMAMG1-22EVALUATION. .GENERAC POWER SYSTEMS..-One reason.for:this confidence is the GENERAC. .
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is•offered with its own transfer systems.and.controls.for
system
..compatibility
O MOBILE.LINO.WI-FI CONNECTIVITY:FREE with select Guardian Series-home.
standby generators,.Mobile Link Wi-Fi allows.users to-monitor the status of.the . . "
generator from anywhere-in the world using a smarlphone; tablet,'or PC. Easily
access-information such as the current operating.status,and maintenance. alerts. .
Users can connect an account to an authorized service dealer'for•fast,frienly;and
proactive.service:With Mobile Link,users.are taken care of before,the next.power. '
outage,
PROMISE �s .��`
_ _ . . .. G E N E,RAC
10/1"4/18 kW Features 'and Senefits
Engine
:• General G-Force design Maximizes engine"breathing"for.increased fuel efficiency.Plateau honed cylinder walls and plasma moly
rings help the engine run cooler,reducing oil consumption and resulting in longer engine life.";
0 "Spinyylok"cast iron cylinder walls. . . Rigid construction and added durability provide long engine life.,
• Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. .
• Full pressure lubrication system. Pressurized:lubrication'to all vital bearings means better performance, less.maintenance; and longer =
engine life:Now featuring up to a 2 year/200.hour oil change interval.
•- "Low oil pressure shritdown.system Shutdown protection prevents.catastrophic engine damage due to low oil. . :-
6 EPA Certified for non-emergencyapplications" Allows'unit to be used for demand response applications:
•" High temperature shutdown Prevents damage due to overheating..
Generator_.
0 Revolving field -Allows for a smaller, light weight unit that operates-25% more efficiently'than-a,revolving armature;
generator. .. .
• . Skewed stator. Produces a smooth output waveform for oompatibilitywith electronic equipment." .-
0 .Displaced phase excitation Maximizes motor-starting capability,. .
4 Automatic voltage regulation Regulating output voltage to+•1%prevents damaging voltage'spikes.
• UL 2200 listed For your safety:
i
Transfer.Switch(if applicable)
0 Fully automatic Transfers vital electrical loads to the energized source of power..
•. NEMA 311. Can be installed inside or outside for maximum flexibility.
0 Remote mounting. Mounts near existing distribution panel for simple,low=cost installation. .
Evolution'" Controls
-AUTO/MANUAL/OFF illuminated buttons Select the operating mode and provide easy;at-a-glance status indication in'any condition.'
0 Two-line multilingualIcl) Provides homeowners easily visible logs of history;maintenance;.and events up to 50 occurrences.
0 Sealed,raised buttons Smooth,weather-resistant user interface forprogramming and operations... _ -
•. -Utility voltage sensing. Constantly monitors utility voltage,setpoints 6.5%dropout,80%pick-up,of standard voltage.
-• . Generatorvoltage sensing Constantly monitors generator voltage to verify the-cleanest-power:is delivered,to the home.'.
•. .Utility.interrupt delay. Prevents nuisance startups of.the engine,adjustable 2-1500 seconds.from the factory.default setting.of
5 seconds by a qualified dealer.
• Engine warm-up Verifies.engine is ready to assume the load.Setpoint.approxi mately 5 seconds."
• Engine cool=down _. ' Allows.engine to cool prior to shutdown..Setpoint approximately 1.minute.
• _Programmable exercise Operates engine to prevenf oil seal drying and damage between-power outages by running the generator
for 5 minutes every other"week."Offers a selectable setting for weekly or monthly operation, providing
flexibility and potentially lower fuel costs to the owner. "
• . Smart battery charger Delivers"charge to the battery only when needed atvarying rates depending on outdoor air temperature.
Compatible with lead.acid and AGM-style batteries:
• Mairi.line circuit breaker Protects generator.from overload.
• Electronic governor 'Maintains constant 60 Hi frequency:. .
Unit.
• SAE weather protective enclosure" -So und"attenuated enclosutes ensure quiet operation and protection against rhother`naturp,withstanding -
- winds up to 150 mph(241 km/h)..Hinged key locking roof panel for security;:Lift-out front for easy access-
to all routine maintenance items.Electrostatically applied textured epoxy•paint for.added'durability: '
0. Enclosed-critical.grade.muffler Ouiet,critical grade muffler-is mounted inside-the unit to prevent injuries. ;
• Small,compact,attractive." . . Makes fotan easy,eye appealing installation,-as.close as 18'in.(457 mm).away'from a.structure.
. ..GENERAC :
1.0/14/18 kW Features and Benefits
Installation System .
.0. 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector forthe.required;connection to the gas supply:
piping '
W. Inte'gral'sedimeni trap . _ _ Meets IFGC and NFPA 54 installation requirements. .. ,.
'Connectivity.
Ability to view.generator status - . Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Link application '
'for complete peace of mind. . .
0 _Ability to view.generator Exercise/Run.and Total Hours Review the generator's-complete.protection.profile for ekejcise hours.and total hours:
•,. Ability to viewgenerator maintenance information Provides maintenance information_for your specific model generatorwhen scheduled maintena' ic'e is due.
Moothly.report with previous month's activity :Detailed monthly reports provide historical generator information.
••'Ability.to view.-generator battery information Builtin battery diagnostics displaying currentstate of the battery. . '
6 -Weather information Provides detailed local'ambient weather conditions for generator location.
. .
GENERAC
10/14/18 kW Specifications;:-
Generator . .
.Model 10 kW 14 kW 18 IN
Rated maximum continuous power capacity(LP) 10,000 Watts* 14,000 Watts* 18,
Rated maximum continuous power capacity(NG) 9,000 Watts` 14,000 Watts* 17,000 Watts'
Rated voltage 240
Rated maximum eontirtuous load current-240 volts(LP/NG) 41.7 137.5 58.3/58.3 75.0/70.8
Total Harm6nic.Distortion Less than 5%
Main line circuit breaker 45 Amp. 60 Amp . . 80 Amp
Phase 1 .
Number of rotor-poles ' 2
Rated AC frequency 60 Hz -
Power factor
Battery requirement(not included). 12 Volts,,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum
Unit weight(lb/kg) 338/153 385/175 420/191
Dimensions(L x W x HpIn/cm 48 x 25 x 29/121.9 x 63.5 x 73.7'
Sound output in dB(A)at 23 ft(7 m)with generator operating abnormal load'*, 61' 65 65
Sound output in dB(A)at 23 ft(7 m)with generator in Quiet-Test'"low-speed exercise mode*. 57. ' 55 55 .
Exercise duration 5 min -
Engine -
Engine type GENERAC G-Force 400 Series- GENERAC G-Force 800 Series
Number of cylinders 1 2
Displacement '460 cc 816 cc.
Cylinder block Aluminum w/cast iron sleeve
Valve arrangement Overhead.valve .
,ftertype Solid-- Hydraulic
Ignition system Solid-state.w/magneto. .
Governor system Electronic
Compression ratio 9.5:1
Starter. 12 VDC
Oil capacity including filter Approx 1.1 qt/1.0 L, Approx:2.2 gt/2.1 L
Operating rpm 3,600
Fuel consumption
Natural Gas ft3/hr(m3/hr)-1/2 Load. 101(2:86) 195(5.52) - 169(4.79)'.,
Full Load, -127(3.60) 256(7.25) 247.(6.99).
Liquid Propane fta/hr(gal/hr).[L/hr],
1/2 Load 36(0,97)[3.66] 65(1.81)[6.87]. 62(1.70)[6.45]
Full Load 54"(1.48)[5.62] 112.(3.07)[11.61] 1.10(3.02[11.441
Note:-Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges'-3.5-7.0 in-water column(0.87-1.74'kPa)for NG,10-12 in water column(2.49-2.99,kPa)for LPI
gas:For BTU content,multiply fts/hr x 2,500(LP)or fts/hr x 1,000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG):
Controls. .
Two-line plain text.multilEgual LCD Simple-user interface for ease of operation.
Mode buttons:AUTO Automatic start'on utility failure:Weekly,Bi-Weekly,or Monthly selectable exerciser.
I —MANUAL' StiFWth starter control,unit stays on.If utility fails,transfer to load takes place.
OFF Stops unit:Power is removed.Control and charger still operate..
Ready to Run/Maintenance messages. Standard.
k
Engine run hours indication .- .
Standard
Programmable start delay between 2-1500 seconds• Standard(programmable by dealer only)
Utility voltage loss/Retum to utility adjustable(b(ownout setting) - From-140-171 V/.190-216 V
Future set capable exerciser/Exercise set error warning Standard-
Run/AlarnUMaintenance logs- 50 events each
Engine start sequence Cyclic cranking:l6 sec on,7 sec•rest(90 sec maximum duration).
Starter.lock-out . Starter cannot re-engage until 5 sec after engine has stopped.
Smait Battery Charger - Standard
Charger Fault/Missing AC Warning Standard.
_ Low BatteryBattery Problem Protection acid Battery Condition Indication Standard
Automatic Voltage Regu.Iation with Over and Under Voltage Protection :- Standard .
Under-Frequency/Overload(Stepper Overcurrent Protection Standard
Safety Fused/Fuse Problem Protection -Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown .; Standard
Overcrank/Overspeed(@ 72 Hz)/rpm Sense Lass Shutdown Standard .
Hig Engine Tempera lure Shutdown Standard _
Internal FaultAncorrectWiring'Protection . Standard
Common External Fault Capability Standard
Field Upgradable Firmware Standard
Rating definitions_Optional Standby:Applicable for supplying.backup.powerfor the'duration of the utility power outage with correct mainternance performed.No overload capability is available for this rating.(All
ratings in accordance with BS5514;IS03046,01-2200,and DIN6271).
*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition;etc:Maximum`power decreases
approximately 3.5%for each 1,000It(304.8-m)above sea level and approximately 1%for each 10 IF(6°C)above 60 IF(16°C):.**Sound'16els are taken from the front of thb generator.-Sound levels tak6 from, ,
other sides of the generator may be higher depending on.installation parameters.
GENERAL
10/14/18 W. Switch.-Options.;] .. .
Model G007172-0 . G00722440
Limited Circuits Switch, (10 kW) (14,kW)
• 16 space;24 circuit.Breakers not included. - No.,of-poles°f; -. ";..: = .2 `
• Electrically operated,mechanically-held contacts for fast;positive connections. Current-rating(amps) -100, :.
--Rated forall classes of.Ioad,-100%equipment rated,.both inductive and Voltage rating(VAC) 120%240,10
resistive: Utility voltage monitor(fixed)*
• .2-pole,250.VAC contactors. -Pick-up 80%• ;
. 30 millisecond transfer.time.'. -Dropout. 65%
0 .Dual coil design:' Returnao utility"; .'' Approx:'15 sec s
0• ,Rated for both copper and aluminum conductors: . Exercises bi-weekly for 5minutes'- Standard
0 -Main contacts are silver plated or silver_alloy to resist welding and sticking.
' ETLorUL;Listed';.""•'� ' �,,-r .;:, _: . : ..•;Standard .
•- 'NEMA/UL"31i aluminum outdoor enclosure allows for indoor or outdoor. Total circuits available 24-
mounting flexibility.. Tandem breaker capabilities
�. Multi listed forbse with 1 in standard;-tandem,GFCI;and AFCI breakerslom
Siemens,Murray;Eaton,-and Square D for the most flexible and cost effective Circuit breaker protected
Available RMS Symmetrical 10,000
install. .
Fault Current @ 250 Volts.
Dtmensi0ns. "Function of Evolution controller
Exercise can be set to-weekly br monthly .
Height -'.Width w,
H11 H2. W1 . W2 . Depth _ *` •
in 26.75 -30.1. 10.5. .13.5. 6.91
cm 67.94. 76.43 26.67 . 34.18 . 17:54. . :�`.,, :;.•' ..
Wire Ranges rs
Conductor Lug Neutral Lug . Ground Lug
2/0-#14 2/0-#14 2/U-#14 . F_ .,
ntrn
_ -Service-Rated.Smart-$Witch FeatUres Model - G007225-10. G007228-10.
0 Includes Smart A/C Management module standard. (14 k1N) (18 kW)
No.-of poles 2 ,
'Intelligently manages up to four air conditioner loadswith'no additional, Currentrating.(amps) 200 .
hardware. -
�.. Up to eight large.(240.VAC)loads can'be managed with Smart Management Voltage"rating(VAC) ';._ :120%240;
Modules-(SMMs). Utility voltage'monitor(fixed)
Electrically operated,mechanically-held contacts for fast,,clean connections. -Pick-up eb%
•'. Rated for all classes-of toad,100%equipment rated,both inductive and -Dropout' 65%_
Return to utility,. Hr•: . ..,-..;1.5sec.
resistive.. "k
• .2.-pole,25Q1IAG contactors. . Exercises bi-weekly for 5 minutes. Standard
• -Service equipment rated,dual coil'design. ETC or UCfListed" ""' ,':, . `:`•";�. .- Standard ,
•.. hated for both aluminum and.copper conductors. Enclosure type NEMA/UL 3R-
0• Main contacts:are silver plated or.silver alloy to resist welding and sticking. .. Circuit breaker_'protected ?2,000
0- NEMA/UL 3R alumiN m outdoor enclosure allows forindoor or outdoor Lug range 250 MCM-#6 :
mounting flexibility. *Function of-Evolution Controller
Exercise.can be set to weekly or monthly.;
Dimensions . .
wt
200 Amps 120/240,It
.tN "
Yl
Open Transition Service Hated•
Height, Width Depth m "
H1 H2 W1 W2
in. 26.75 :30.1 10.5 13.5 :6,3 Mi
cm 67:94. 76:45. 26.67• -34:3. 16:01
Wire ariges J44•
Conductor Lug• Neutral Lug .- Ground Lug
400 MCM-#4. 350 MCM-#6. . . . 2/0.-#14 . .
GENERAL®
10/14/18 :kW : Available Accessories
Model# Product' Description
G005819=0 ' 26R'Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended"26R wet Bell"bat-
tery for use with all air-cooled standby product(excluding PowerPact°).,.
G007101-0 Battery Pad Warmer -. The..pad wammer rests under the battery:-Recommended for use.if the•temperature regularly falls below 0'F�(-18 .
°C).(Not necessary for use with AGM-style batteries).. .
G007102-0 Oil Warmer Oil wanner slips directly overthe oil filter.,Recommended for use if the temperature regularly falls,below 0*F(-I 8.'C).'
G007103-1 - Breather Warmer.. The-breather warmer is for use in extreme cold weather-applications.For use with Evolution'controllers only in
climates where heavy icing occurs.
G005621-0' .' Aaxiliary.Transfer.Switch- The auxiliary transfer switch contact kit allows the transfer'switch to lock out a single Iarge,'electrical load you may. '.
Contact Kit not need.Not compatible with 50 amp pre-wired_switches.
G007027-0 Bisque Fascia Base Wrap Kit The fascia.base wrap snaps together around.the bottom of the new air cooled.generators,This offers a sleek,con-
toured appearance as well as offering protection from rodents and insects by covering the lifting holes'located in
the'base,
G005703-0-::Bisque Touch-Up.Paint Kit If the:generator enclosure is'seratched or damaged,it is important to touch up'the paint to'protect from future
corrosion.The touch=up.paint kit'includes the necessary.paint to•correctiy maintain or touch up a.generator en- .
closure..
G006482-0.-10 kW Scheduled,Maintenance Kit . .Generac's scheduled maintenance kits provide all the items-necessary-to perform complete routine maintenance "
G007216-6- 14/18 kW ona Generac automatic standby generator.(oil not,included):. _
130070094- LTE LP Fuel Level Monitor The LTE enabled LP fuel level monitor provides constant monitoring of the connected.LP fuel tank:.Monitoring the
LP tank's fuel level is'an important step in verifying.the generator is ready to run during an unexpected powerfail-,
ure.-Status alerts are available through a free application to notify users when the LP tank is in need of a refill:
G007000-0(50 amps) Smart Management Module Smart Management Modules (SMM)are used to optimize the performance of a standby generator:it manages
G007006-0(100 amps) large electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,`using.
SMM's can reduce the overall size and cost of the system.
G007169-0(413 LTE) Mobile Link.. .Cellular. The.Mobile Link family of-Cellular Accessories allow users to monitorthe status of the generator.from,•anywhere
G007170-0.(IIVi Fi/Ether- . Accessories in the world,using a smartphone,tablet;or.PC.Easily access information such as the current operating status and '
net) maintenance alerts.-Users can connect an account with an authorized.serVice dealer for fast,friendly,and proac-
tive service.With Mobile Link,users are taken care of before the next power outage. ,
G007220-0-Bisque Base Plug Kit" Base plugs snap into the lifting holes on the base of air-cooled home standby generators,This offers a sleek,con-
toured appearance,as well as offers protection from rodents and insects by covering-the lifting-holes located in
the.base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator:,
Dimensions &. Ms.
1218 mm '
637.E mm - 148.0 In]: ..
Model UPC-..
G007171.- " 696471074680 . . :.
G007172 ' 696471074673 .
13007223 -696471.082548- 72.2mn
G007224 .696471082555.. .
13007225•- 696471082562
G00728- '696471082579. ' u' a o
G007228 696471082586_
648 mm _ 1232. I '
- [25.51n1' - - - (45.51n1. . . ..
. - LEFT SIDE VIEW. - - FRONT VIEW
Dimensions'shbwn are approAmate.See installation manual for ei act dimensions:DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES..
GENE RAC® Generac Power Systems;Inc:.i S45 W29290 HWY:59,Waukesha,WI 53189 gene,rac.com
@2022 Generac Power systems,Inc.All rights reserved.-All specifications are subject to change.without notice.Part No.A0000973374 Rev:C 09/19/2022