HomeMy WebLinkAbout50382-Z o01gtlFFO(�-�pG Town of Southold 5/31/2024 P.O.Box 1179 C. o _ 53095 Main Rd yfj0l �ao ;r Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45239 Date: 5/31/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 14995 Oregon Rd, Cutchogue SCTM#: 473889 Sec/Block/Lot: 73.-1-2.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/26/2024 pursuant to which Building Permit No. 50382 dated 2/29/2024 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for(by accessory garage). The certificate is issued to Olsen Family 2020 Trt of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50382 4/8/2024 PLUMBERS CERTIFICATION DATED th riz d ignature ��o�SyFFoi,t TOWN OF SOUTHOLD BUILDING DEPARTMENT y, TOWN CLERK'S OFFICE • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50382 Date: 2/29/2024 Permission is hereby granted to: Olsen Family 2020 Trt 149 Brewster Rd Massapequa, NY 11758 To: install generator as applied for (accessory garage). At premises located at: 14995 Oregon Rd, Cutchogue SCTM #473889 Sec/Block/Lot# 73.-1-2.2 Pursuant to application dated 1/26/2024 and approved by the Building Inspector. To expire on 8/30/2025. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector pF SOUl��l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q • �o Southold,NY 1197]-0959 sean.devlin(&-town.south old.ny.us �Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Olsen Family 2020 Trust Address: 14995 Oregon Rd city:Cutchogue st: NY zip: 11935 Building Permit#: 50382 Section: 73 Block: 1 Lot: 2.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: G&S Electric License No: 578ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Garage X Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 18kW Generac Generator w/200A Transfer Switch Notes: Generator Inspector Signature: '- Date: April 8, 2024 S.Devlin-Cert Electrical Compliance Form OF 80UT9p� # * TOWN OF SOUTHOLD BUILDING DEPT. `ycourm 631-765-1802 v INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL bey [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] .FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE O [ ] RENTAL REMARKS: i tCi DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS ro FOUNDATION (1ST) — -- --- -- — w -------------------------------------- FOUNDATION (2ND) ----- — Z O ROUGH FRAMING& — - PLUMBING — INSULATION PER N.Y. --- "3 STATE ENERGY CODE S FINAL ADDITIONAL COMMENTS r y ��la E�e�ck�c Ce � cn► — o 9-1 o =�gUFFO[K�OGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownnygov Date Received APPLICATION FOR BUILDING PERMIT V-- Builcling For Office Use OnlyPERMIT NO. Inspector: J 2 5 A N 2024 'Applications and forms must be filled out in their entirety.,Incomplete applications will not be accepted- Where the Applicant is not the owner,an s¢�IlcfEr� °pa en Owner's Authorization form(Page 2)shall be completed. _ Town of Southold Date: �f a F OWNER(S) PRO RTY: - Name: SCTM#1000- Project Address: Phone# V _la---_ �' Email:--- Mailing Address: r- __--------------- -- ---- --�- - -/�c-Grr-sue--- - --- - - - -�- - - - - - - -� - - - -- --I -- ems'----- CONTACT=PERSON:' Name: Mailing Address: Phone#: S—l6_._�' �-__------------- Email:_-� --------- DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: I CONTRACTOR INFORMATION: ' Name: -- // dMailing A _.ess:.__�_. A4 _6-.'" ..C-----•-- ----�.. _ .-- -3�-------------_.__--__ Phone#: ail:Em eom/S-rsu e. _- --- DESCRIPTION'OF PROPOSED CONSTRUCTION ❑New Structure ❑Addi ion ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: tt--her% D C b1 , $ Will the lot be re-graded? ❑Yes XNo Will excess fill be removed from premises? Dyes ANO 1 I PROPERTY INFORMATION Existing use of property: Intended use of property: Zone.or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ONO IF YES, PROVIDE A COPY_`_ �Check Box After Reading:_ The owner/contractor/design professional is responsible for all drainage and storm'water issues as provided by. pter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition'as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, -housing code and'regulatiohs and to admit authorized inspectors on premises and in building(s)'for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): (Authorized Agent ❑Owner Signature of Applicant: Date_STATE OF OF NEW YORK) SS: COUNTY OF 511 r-P6 4- ✓�) ter L�/UL� /�7 URrS- being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the �d-CN 1(!QA;r". C-7_A< (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ,20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at T7- /'cC do hereby authorize L=. �(4,6ye-- ,L7 wg c-cff to apply on my behalf to the Town of Southold Building Department for approval as described herein. �1 Owner's Signature Date y L3D RA4 DL.S a Al Print Owner's Name 2 o�oS�FFp��C' BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o =` Town Hall Annex- 54375 Main Road - PO Box 1179 e ^ Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 Ia mesh CaD-southoldtownny.gov - seanda-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/25/24 Company Name: G & S Electrical Electrician's Name: Bob Guariello License No.: 31568-ME Elec. email: gs1641 @aol.com Elec. Phone No: 631-765-1641 ❑✓ I request an email copy of Certificate of Compliance Elec. Address.: 250 Budd's Pond Road, Southold, NY 1,1971 JOB SITE INFORMATION (All Information Required) Name: Olson Family 2020 Trust Address: 14995 Oregon Road, Cutchogue, NY 11935 Cross Street: Bridge Lane Phone No.: 516-695-0583 Bldg.Permit#: r���a email: dolson43@aol.com Tax Map District: 1000 Section: 73• Block: -1 Lot: -2.2 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Generator Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Recon'nect❑Underground❑Overhead # Underground Laterals 1 R2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION BUILDING DEPARTMENT- Electrical Inspector ��O Gy.► TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 *► Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh southoidtownny.gov — sea ndCcrD_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/25/24 Company Name: G & S Electrical Electrician's Name: Bob Guariello License No.: 31568-ME Elec. email: gs1641 @aol.com Elec. Phone No: 631-765-1641 ❑✓ I request an email copy of Certificate of Compliance Elec. Address.: 250 Budd's Pond Road, Southold, NY 11971 JOB SITE INFORMATION (All Information Required) Name: Olson Family 2020 Trust Address: 14995 Oregon Road, Cutchogue, NY 11935 Cross Street: Bridge Lane Phone No.: 516-695-0583 Bldg.Permit#: F-LD- email: dolson43@aol.com Tax Map District: 1000 Section:73• Block: -1 Lot: -2.2 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Generator 11 2d Square Footage: Circle All That Apply: Is job ready for inspection?: ✓❑ YES ❑ NO ❑Rough In W Final Do you need a Temp Certificate?: ❑ YES ✓0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 0 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION SURVEY OF CERRFIED TO.DEBORAHOLSON WAYNEOLSON DESCRIBED PROPERTY LONG ISLAND SOUND SITUAOFS TE AT CUTCHOGUE N6728, SUFFOIKCO MYUNEWYORK JOBNO.:2=-196 2B.6T ^m, SCT.M DIST.f003 SEC.73 BLK 1 LOT22 MAPNO..,25 5p g15p�� �7g FILED: 25 13 0 SL'A<E 1,-50' 75 f00 DATE:DECEMBER2,207P 200 225 LOC/FOUNDARON:fMM \ AS$UILTSURVEY.'1624l23 1 \I LOTAREA:581,596SD.FT.-M MACRES \ SANTARYLOCARONOIMENSIONS p.�EOF NEly pp MAINDWELLING GARAGE S�p?�'•�W COASTAL�1 \asp. CORNERA 27� � CORNER 42 52' H Q ll CORNERS 31' 5P CORNER 19' 38, -�yNDARY sm p� LAMA \N 1 04g z m c TS C 9 S. t N f �$ JEFFREYW..HAVERERLS \ m9 Ai LCENSEN0:050538 g � r TwFam- LAND SURVEYING 18HAMPTONBAAYS,UK I M MY YOPX 11946 1 s M 631-369-8312-(F)631-3694313 ema2'nfiNNrislandsNrve hoN.ronT \ COMESOFRB4SURVEYM49 EIM MPAPEROR ELECIROMA NOTBWM MELANDSURVEYORSPN(ED SEAL OR MWS6EDSFJLL SHALL NOT BE q COWDERED TO BEA VAUDCOPYAND MALL NOTBEUSMFORANYPURPOSE cASTLE HILL ROAD-- DIGITAL RELEASE N \ \ 13.65 tuA6 N 5123'30'E �' N 1 . �NUPO6?EMPEPLlxE Matl N 31"2E20•E T E R,f36 ei YfE 11�E 1 1 1 'M.taTE 'PN fAE aee y , 1 \ 93 1 1%Z M 1F hL F\ \I � C N p Z m mp a T T S9 L 99 i { A� yg5 $g O N qq L 4`1 M \1 T2H' \ 124.101 W\�•6���.�. 64<g10 �4G 'i. �j pyitlE 1 ,�S� 138 m /••i� y 243.85 Jxe _ �J 1 N �• 4 81' 6y6EOPPAVENen Q i S12p"W m IIM � f13P �6A4M / EWEOPPAYENBA oREGON ROAD L:63.T are Z m LOTAREATOMETE38BOUNDSASSHOY1N:581,WOSD.FT:-fa352ACM ELEVA'ON", ONREFER 70 NA.'. APP 0 EO AS NOTED DAM• .R# ao FEE �bb BY NOTIFY BUILDING DEPARTMENT AT 631 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUM,91I,►G 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL_ MEET THE REQUIREMENTS OF THE CODES 0�'NEV-J YORK STATE. NOT RESPOi,0,13LE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CO DITIONS OF SOUTHOLD rOWIN SOUTHO N ZBA PLAN NING BOARD SOUTH TOWN TRUSTEES HPC OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT" OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED -GUARDIAN® _SERIES 10/14 8 k _. . Residential:Standby G-enerators•. : Air=Cooled Gas•Engine . , INCLUDES:. . Standby Fower:Ratin9 Go07171-0;Gb07112-0(Aluminum--Bisque)--10 kW 60 Hz • .True PowerT" Electrical Technology G007223-10,.G007224-10,G007225-10(Aluminum=Bisque).-14 kW 60 Hz • Two-line multilingual digital LCD Evolution"' controller G007226-10,G007228-10.(Aluminum-Bisque)-1a kW,fiO Hz (English/Span ish/French/Portug uese)- • Two transfer switch options available: 1 QO amp 16-circuit switch or , .ROO amp.service rated smart switch •. - Electronic-goyerrtor, .�1 .. • Standard Wi-Fi(P connectivity • System status&maintenance interval LED indicators • .Sound attenuated enclosure. GENE�RAC' — . Flexible-fuel line connector • .-Natural gas or.LP.gas operation. r • 5 Year limited warranty. 0 Listed and.labeled'for installation as close as 18 in.457. ' - i ( Product shown with.oplional fascia kit' - - mrri).to a structure.*. ' *Must be located.away from doors, windows, and'fresh or C UL US air.intakes and in accordance with loca/.codes. . ET1/.us O QUA . . . LISTED . . Note:CUL or CUL certification only applies fo unbundled units and'units packaged with limited circuit switches.Units packaged with'the Smart Switch are ErL or UL certified in the USA only.; FEATURES O. INNOVATIVE ENGINE DESIGN-&. RIGOROUS. TESTING are at the'heart of. O'. SOLID-STATE, FREQUENCY.COMPENSATED VOLTAGE REGULATION:.This'.i Generac's success in providing the most reliable-generators possible.Generac's G- state-of=the-art.power.maximizing regulation System is'•-standard:on all Generac Force engine_lineup offers added peace of mind.and.reliability for when you need,it . . .models.-It provides optimized FAST RESPONSE to,changing.load.conditions'and - . the most.The.G-Force series engines are purpose builtaod designed to.handle the MAXIMUM-MOTOR STARTING CAPABILITY by,electronically.torque-matching.the rigors of extended run times in,high temperatures and extreme operating conditions. . surge loads to the engine.Digital.voltage regulation,at-4-1 -O TRUE POWER-ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave -O SINGLE SOURCE SERVICE RESPONSE from.Generac'•s exte.ns,ive.dealer.network form produce less than 5%Total Harmonic-Distortion for utility quality power.This. provides-parts and service know-how-for the 6ritire unit, from the,`engin.e to the.. allows confident operation of sensitive electronic equipment and micro-chip based .-.smallest electronic com_ponent.. appliances,such as variable speed HVAC systems. O. TEST CRITERIA: O. GENERAL.TRANSFER SWITCHES:.Long'life'and reliability are synonymous with ✓ PROTOTYPE TESTED, ✓ NEMAMG1-22EVALUATION. .GENERAC POWER SYSTEMS..-One reason.for:this confidence is the GENERAC. . ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is•offered with its own transfer systems.and.controls.for system ..compatibility O MOBILE.LINO.WI-FI CONNECTIVITY:FREE with select Guardian Series-home. standby generators,.Mobile Link Wi-Fi allows.users to-monitor the status of.the . . " generator from anywhere-in the world using a smarlphone; tablet,'or PC. Easily access-information such as the current operating.status,and maintenance. alerts. . Users can connect an account to an authorized service dealer'for•fast,frienly;and proactive.service:With Mobile Link,users.are taken care of before,the next.power. ' outage, PROMISE �s .��` _ _ . . .. G E N E,RAC 10/1"4/18 kW Features 'and Senefits Engine :• General G-Force design Maximizes engine"breathing"for.increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life."; 0 "Spinyylok"cast iron cylinder walls. . . Rigid construction and added durability provide long engine life., • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. . • Full pressure lubrication system. Pressurized:lubrication'to all vital bearings means better performance, less.maintenance; and longer = engine life:Now featuring up to a 2 year/200.hour oil change interval. •- "Low oil pressure shritdown.system Shutdown protection prevents.catastrophic engine damage due to low oil. . :- 6 EPA Certified for non-emergencyapplications" Allows'unit to be used for demand response applications: •" High temperature shutdown Prevents damage due to overheating.. Generator_. 0 Revolving field -Allows for a smaller, light weight unit that operates-25% more efficiently'than-a,revolving armature; generator. .. . • . Skewed stator. Produces a smooth output waveform for oompatibilitywith electronic equipment." .- 0 .Displaced phase excitation Maximizes motor-starting capability,. . 4 Automatic voltage regulation Regulating output voltage to+•1%prevents damaging voltage'spikes. • UL 2200 listed For your safety: i Transfer.Switch(if applicable) 0 Fully automatic Transfers vital electrical loads to the energized source of power.. •. NEMA 311. Can be installed inside or outside for maximum flexibility. 0 Remote mounting. Mounts near existing distribution panel for simple,low=cost installation. . Evolution'" Controls -AUTO/MANUAL/OFF illuminated buttons Select the operating mode and provide easy;at-a-glance status indication in'any condition.' 0 Two-line multilingualIcl) Provides homeowners easily visible logs of history;maintenance;.and events up to 50 occurrences. 0 Sealed,raised buttons Smooth,weather-resistant user interface forprogramming and operations... _ - •. -Utility voltage sensing. Constantly monitors utility voltage,setpoints 6.5%dropout,80%pick-up,of standard voltage. -• . Generatorvoltage sensing Constantly monitors generator voltage to verify the-cleanest-power:is delivered,to the home.'. •. .Utility.interrupt delay. Prevents nuisance startups of.the engine,adjustable 2-1500 seconds.from the factory.default setting.of 5 seconds by a qualified dealer. • Engine warm-up Verifies.engine is ready to assume the load.Setpoint.approxi mately 5 seconds." • Engine cool=down _. ' Allows.engine to cool prior to shutdown..Setpoint approximately 1.minute. • _Programmable exercise Operates engine to prevenf oil seal drying and damage between-power outages by running the generator for 5 minutes every other"week."Offers a selectable setting for weekly or monthly operation, providing flexibility and potentially lower fuel costs to the owner. " • . Smart battery charger Delivers"charge to the battery only when needed atvarying rates depending on outdoor air temperature. Compatible with lead.acid and AGM-style batteries: • Mairi.line circuit breaker Protects generator.from overload. • Electronic governor 'Maintains constant 60 Hi frequency:. . Unit. • SAE weather protective enclosure" -So und"attenuated enclosutes ensure quiet operation and protection against rhother`naturp,withstanding - - winds up to 150 mph(241 km/h)..Hinged key locking roof panel for security;:Lift-out front for easy access- to all routine maintenance items.Electrostatically applied textured epoxy•paint for.added'durability: ' 0. Enclosed-critical.grade.muffler Ouiet,critical grade muffler-is mounted inside-the unit to prevent injuries. ; • Small,compact,attractive." . . Makes fotan easy,eye appealing installation,-as.close as 18'in.(457 mm).away'from a.structure. . ..GENERAC : 1.0/14/18 kW Features and Benefits Installation System . .0. 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector forthe.required;connection to the gas supply: piping ' W. Inte'gral'sedimeni trap . _ _ Meets IFGC and NFPA 54 installation requirements. .. ,. 'Connectivity. Ability to view.generator status - . Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Link application ' 'for complete peace of mind. . . 0 _Ability to view.generator Exercise/Run.and Total Hours Review the generator's-complete.protection.profile for ekejcise hours.and total hours: •,. Ability to viewgenerator maintenance information Provides maintenance information_for your specific model generatorwhen scheduled maintena' ic'e is due. Moothly.report with previous month's activity :Detailed monthly reports provide historical generator information. ••'Ability.to view.-generator battery information Builtin battery diagnostics displaying currentstate of the battery. . ' 6 -Weather information Provides detailed local'ambient weather conditions for generator location. . . GENERAC 10/14/18 kW Specifications;:- Generator . . .Model 10 kW 14 kW 18 IN Rated maximum continuous power capacity(LP) 10,000 Watts* 14,000 Watts* 18, Rated maximum continuous power capacity(NG) 9,000 Watts` 14,000 Watts* 17,000 Watts' Rated voltage 240 Rated maximum eontirtuous load current-240 volts(LP/NG) 41.7 137.5 58.3/58.3 75.0/70.8 Total Harm6nic.Distortion Less than 5% Main line circuit breaker 45 Amp. 60 Amp . . 80 Amp Phase 1 . Number of rotor-poles ' 2 Rated AC frequency 60 Hz - Power factor Battery requirement(not included). 12 Volts,,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit weight(lb/kg) 338/153 385/175 420/191 Dimensions(L x W x HpIn/cm 48 x 25 x 29/121.9 x 63.5 x 73.7' Sound output in dB(A)at 23 ft(7 m)with generator operating abnormal load'*, 61' 65 65 Sound output in dB(A)at 23 ft(7 m)with generator in Quiet-Test'"low-speed exercise mode*. 57. ' 55 55 . Exercise duration 5 min - Engine - Engine type GENERAC G-Force 400 Series- GENERAC G-Force 800 Series Number of cylinders 1 2 Displacement '460 cc 816 cc. Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead.valve . ,ftertype Solid-- Hydraulic Ignition system Solid-state.w/magneto. . Governor system Electronic Compression ratio 9.5:1 Starter. 12 VDC Oil capacity including filter Approx 1.1 qt/1.0 L, Approx:2.2 gt/2.1 L Operating rpm 3,600 Fuel consumption Natural Gas ft3/hr(m3/hr)-1/2 Load. 101(2:86) 195(5.52) - 169(4.79)'., Full Load, -127(3.60) 256(7.25) 247.(6.99). Liquid Propane fta/hr(gal/hr).[L/hr], 1/2 Load 36(0,97)[3.66] 65(1.81)[6.87]. 62(1.70)[6.45] Full Load 54"(1.48)[5.62] 112.(3.07)[11.61] 1.10(3.02[11.441 Note:-Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges'-3.5-7.0 in-water column(0.87-1.74'kPa)for NG,10-12 in water column(2.49-2.99,kPa)for LPI gas:For BTU content,multiply fts/hr x 2,500(LP)or fts/hr x 1,000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG): Controls. . Two-line plain text.multilEgual LCD Simple-user interface for ease of operation. Mode buttons:AUTO Automatic start'on utility failure:Weekly,Bi-Weekly,or Monthly selectable exerciser. I —MANUAL' StiFWth starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit:Power is removed.Control and charger still operate.. Ready to Run/Maintenance messages. Standard. k Engine run hours indication .- . Standard Programmable start delay between 2-1500 seconds• Standard(programmable by dealer only) Utility voltage loss/Retum to utility adjustable(b(ownout setting) - From-140-171 V/.190-216 V Future set capable exerciser/Exercise set error warning Standard- Run/AlarnUMaintenance logs- 50 events each Engine start sequence Cyclic cranking:l6 sec on,7 sec•rest(90 sec maximum duration). Starter.lock-out . Starter cannot re-engage until 5 sec after engine has stopped. Smait Battery Charger - Standard Charger Fault/Missing AC Warning Standard. _ Low BatteryBattery Problem Protection acid Battery Condition Indication Standard Automatic Voltage Regu.Iation with Over and Under Voltage Protection :- Standard . Under-Frequency/Overload(Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection -Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown .; Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Lass Shutdown Standard . Hig Engine Tempera lure Shutdown Standard _ Internal FaultAncorrectWiring'Protection . Standard Common External Fault Capability Standard Field Upgradable Firmware Standard Rating definitions_Optional Standby:Applicable for supplying.backup.powerfor the'duration of the utility power outage with correct mainternance performed.No overload capability is available for this rating.(All ratings in accordance with BS5514;IS03046,01-2200,and DIN6271). *Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition;etc:Maximum`power decreases approximately 3.5%for each 1,000It(304.8-m)above sea level and approximately 1%for each 10 IF(6°C)above 60 IF(16°C):.**Sound'16els are taken from the front of thb generator.-Sound levels tak6 from, , other sides of the generator may be higher depending on.installation parameters. GENERAL 10/14/18 W. Switch.-Options.;] .. . Model G007172-0 . G00722440 Limited Circuits Switch, (10 kW) (14,kW) • 16 space;24 circuit.Breakers not included. - No.,of-poles°f; -. ";..: = .2 ` • Electrically operated,mechanically-held contacts for fast;positive connections. Current-rating(amps) -100, :. --Rated forall classes of.Ioad,-100%equipment rated,.both inductive and Voltage rating(VAC) 120%240,10 resistive: Utility voltage monitor(fixed)* • .2-pole,250.VAC contactors. -Pick-up 80%• ; . 30 millisecond transfer.time.'. -Dropout. 65% 0 .Dual coil design:' Returnao utility"; .'' Approx:'15 sec s 0• ,Rated for both copper and aluminum conductors: . Exercises bi-weekly for 5minutes'- Standard 0 -Main contacts are silver plated or silver_alloy to resist welding and sticking. ' ETLorUL;Listed';.""•'� ' �,,-r .;:, _: . : ..•;Standard . •- 'NEMA/UL"31i aluminum outdoor enclosure allows for indoor or outdoor. Total circuits available 24- mounting flexibility.. Tandem breaker capabilities �. Multi listed forbse with 1 in standard;-tandem,GFCI;and AFCI breakerslom Siemens,Murray;Eaton,-and Square D for the most flexible and cost effective Circuit breaker protected Available RMS Symmetrical 10,000 install. . Fault Current @ 250 Volts. Dtmensi0ns. "Function of Evolution controller Exercise can be set to-weekly br monthly . Height -'.Width w, H11 H2. W1 . W2 . Depth _ *` • in 26.75 -30.1. 10.5. .13.5. 6.91 cm 67.94. 76.43 26.67 . 34.18 . 17:54. . :�`.,, :;.•' .. Wire Ranges rs Conductor Lug Neutral Lug . Ground Lug 2/0-#14 2/0-#14 2/U-#14 . F_ ., ntrn _ -Service-Rated.Smart-$Witch FeatUres Model - G007225-10. G007228-10. 0 Includes Smart A/C Management module standard. (14 k1N) (18 kW) No.-of poles 2 , 'Intelligently manages up to four air conditioner loadswith'no additional, Currentrating.(amps) 200 . hardware. - �.. Up to eight large.(240.VAC)loads can'be managed with Smart Management Voltage"rating(VAC) ';._ :120%240; Modules-(SMMs). Utility voltage'monitor(fixed) Electrically operated,mechanically-held contacts for fast,,clean connections. -Pick-up eb% •'. Rated for all classes-of toad,100%equipment rated,both inductive and -Dropout' 65%_ Return to utility,. Hr•: . ..,-..;1.5sec. resistive.. "k • .2.-pole,25Q1IAG contactors. . Exercises bi-weekly for 5 minutes. Standard • -Service equipment rated,dual coil'design. ETC or UCfListed" ""' ,':, . `:`•";�. .- Standard , •.. hated for both aluminum and.copper conductors. Enclosure type NEMA/UL 3R- 0• Main contacts:are silver plated or.silver alloy to resist welding and sticking. .. Circuit breaker_'protected ?2,000 0- NEMA/UL 3R alumiN m outdoor enclosure allows forindoor or outdoor Lug range 250 MCM-#6 : mounting flexibility. *Function of-Evolution Controller Exercise.can be set to weekly or monthly.; Dimensions . . wt 200 Amps 120/240,It .tN " Yl Open Transition Service Hated• Height, Width Depth m " H1 H2 W1 W2 in. 26.75 :30.1 10.5 13.5 :6,3 Mi cm 67:94. 76:45. 26.67• -34:3. 16:01 Wire ariges J44• Conductor Lug• Neutral Lug .- Ground Lug 400 MCM-#4. 350 MCM-#6. . . . 2/0.-#14 . . GENERAL® 10/14/18 :kW : Available Accessories Model# Product' Description G005819=0 ' 26R'Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended"26R wet Bell"bat- tery for use with all air-cooled standby product(excluding PowerPact°).,. G007101-0 Battery Pad Warmer -. The..pad wammer rests under the battery:-Recommended for use.if the•temperature regularly falls below 0'F�(-18 . °C).(Not necessary for use with AGM-style batteries).. . G007102-0 Oil Warmer Oil wanner slips directly overthe oil filter.,Recommended for use if the temperature regularly falls,below 0*F(-I 8.'C).' G007103-1 - Breather Warmer.. The-breather warmer is for use in extreme cold weather-applications.For use with Evolution'controllers only in climates where heavy icing occurs. G005621-0' .' Aaxiliary.Transfer.Switch- The auxiliary transfer switch contact kit allows the transfer'switch to lock out a single Iarge,'electrical load you may. '. Contact Kit not need.Not compatible with 50 amp pre-wired_switches. G007027-0 Bisque Fascia Base Wrap Kit The fascia.base wrap snaps together around.the bottom of the new air cooled.generators,This offers a sleek,con- toured appearance as well as offering protection from rodents and insects by covering the lifting holes'located in the'base, G005703-0-::Bisque Touch-Up.Paint Kit If the:generator enclosure is'seratched or damaged,it is important to touch up'the paint to'protect from future corrosion.The touch=up.paint kit'includes the necessary.paint to•correctiy maintain or touch up a.generator en- . closure.. G006482-0.-10 kW Scheduled,Maintenance Kit . .Generac's scheduled maintenance kits provide all the items-necessary-to perform complete routine maintenance " G007216-6- 14/18 kW ona Generac automatic standby generator.(oil not,included):. _ 130070094- LTE LP Fuel Level Monitor The LTE enabled LP fuel level monitor provides constant monitoring of the connected.LP fuel tank:.Monitoring the LP tank's fuel level is'an important step in verifying.the generator is ready to run during an unexpected powerfail-, ure.-Status alerts are available through a free application to notify users when the LP tank is in need of a refill: G007000-0(50 amps) Smart Management Module Smart Management Modules (SMM)are used to optimize the performance of a standby generator:it manages G007006-0(100 amps) large electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,`using. SMM's can reduce the overall size and cost of the system. G007169-0(413 LTE) Mobile Link.. .Cellular. The.Mobile Link family of-Cellular Accessories allow users to monitorthe status of the generator.from,•anywhere G007170-0.(IIVi Fi/Ether- . Accessories in the world,using a smartphone,tablet;or.PC.Easily access information such as the current operating status and ' net) maintenance alerts.-Users can connect an account with an authorized.serVice dealer for fast,friendly,and proac- tive service.With Mobile Link,users are taken care of before the next power outage. , G007220-0-Bisque Base Plug Kit" Base plugs snap into the lifting holes on the base of air-cooled home standby generators,This offers a sleek,con- toured appearance,as well as offers protection from rodents and insects by covering-the lifting-holes located in the.base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator:, Dimensions &. Ms. 1218 mm ' 637.E mm - 148.0 In]: .. Model UPC-.. G007171.- " 696471074680 . . :. G007172 ' 696471074673 . 13007223 -696471.082548- 72.2mn G007224 .696471082555.. . 13007225•- 696471082562 G00728- '696471082579. ' u' a o G007228 696471082586_ 648 mm _ 1232. I ' - [25.51n1' - - - (45.51n1. . . .. . - LEFT SIDE VIEW. - - FRONT VIEW Dimensions'shbwn are approAmate.See installation manual for ei act dimensions:DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.. GENE RAC® Generac Power Systems;Inc:.i S45 W29290 HWY:59,Waukesha,WI 53189 gene,rac.com @2022 Generac Power systems,Inc.All rights reserved.-All specifications are subject to change.without notice.Part No.A0000973374 Rev:C 09/19/2022