Loading...
HomeMy WebLinkAbout49473-Z �S�FF01��OG Town of Southold 5/30/2024 0 P.O.Box 1179 o _ 53095 Main Rd �,ao Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45229 Date: 5/30/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 3280 Wunneweta Rd, Cutchogue SCTM#: 473889 Sec/Block/Lot: 111.-11-30 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/7/2023 pursuant to which Building Permit No. 49473 dated 7/14/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Laddy,Stephen&Okin,Ellen of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49473 1/24/2024 PLUMBERS CERTIFICATION DATED A or' d Signatur ��o�SOFFoc�.�oG TOWN OF SOUTHOLD BUILDING DEPARTMENT 1 x TOWN CLERK'S OFFICE Woy • o�� SOUTHOLD, NY col. �a v BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49473 Date: 7/14/2023 Permission is hereby granted to: Laddy, Stephen 66 Kendrick Ln Dix Hills, NY 11746 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 3280 Wunneweta Rd, Cutchogue "1 SCTM #473889 Sec/Block/Lot# 111.-11-30 Pursuant to application dated 6/7/2023 and approved by the Building Inspector. To expire on 1/12/2025. Fees: J SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELL114G $50.00 Total: $200.00 Building Inspector OF SO�r�o! � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q �O • yo sean.devlinCu-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Stephen Laddy Address: 3280 Wunneweta-Rd city:Cutchogue st: NY zip: 11935 Building Permit#: 49473 Section: 111 Block: 11 Lot: 30 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: GreenLogicLLC License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO . Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump -11 Other Equipment: 14.025kW Roof Mounted PV Solar Energy System w/ (33) SunPower SPR M425 H Modules, AC Combiner Panel , 70A AC Disconnect Notes: Solar Inspector Signature: Date: January 24, 2024 S. Devlin-Cert Electrical Compliance Form oF socryolo # # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION —] PRE C/O [ ] RENTAL fo, REMARKS: � r DATE INSPECTOR SOUlyolo TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [WINAL SrOlar— FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLA TION [ ] PRE C/O [ ] RENTAL REMARKS: //7 \)92 DATE �a INSPECTOR ]FIELD INSPECTION REPORT DATE COMMENTS -'Zib FOUNDATION (IST) ------------------------------------ C rA FOUNDATION (2ND) � O ROUGH FRAMING& PLUMBING S y ro INSULATION PER N.Y-. `3 STATE ENERGY CODE O •�'a s� s I Ce.e . Akvx4 ,%. FINAL ADDITIONAL COMMENTS o //-aY P6 sir sue-// exAz Z X x \y O H C[ C ' b H TOWN OF SOUTHOLD—BUILDING DEPARTMENT x14 Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Qy • o� Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT _1l _ 4 JV For Office Use Only cla ! { PERMIT NO. L4 Building Inspector: JUN _ 7 2023 `ApplicationsAnd forms rriust be.filled out in,their enti�et}I pn grnplete .,.. �'.. "7a,i};:.,nip s ':�s applications;will-;not'be,accepted:.Where,the;A Tlicant is not the ownec;,an',, j; ` Owner's Authorization fOrm(Page'2)shall be completed , , Date:6/7/2023 OWNERS)I'OF PROPERTY Name:StephenLaddY.........._ ...,. _.. ...... ... scrnn#^s000-1.11.-11-30.. ._. ............_ _..... _ __......._._....., Project Address:3280 Wunneweta_Road, Cutchogue, NY Phone#:347-258-8642 ry _.__. _ Email:sladdy923@gmail,-com Mailing Address:66 Kendrick Lane,_Dix H Ills,.NY 11746 _CONTACT PERSON. Name:Barbara - GreenLogic„LLC„ Mailing Address:97 North Sea,Road,_Southampton,.NY, 1196.8 Phone#:631-771-55152 x117------- „------- Fi7ai,:Barbara@Qreen[ggic.com_ DESIGN PROFESSION INFORMATION �., ii Name:James J Stout Architect & Associates Mailing Address:2 Greg Lane, E. Northport, NY 11731 Phone#:631-858-9388 m__ _ Email:stouthubOiamesstoutarch.com CONTRACTOR;INFORMATION: .; M Name:Green Logic LLC Mailing Address:97 North Sea Road, Southampton,,NY, 11968 Phone#:631-771-5152 Email:AM@Greenlogic.corn 'bESCRIPTION.OF,PRQP4SED.CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: 90ther Solar Panels $ 53,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes 9No IF YES,PROVIDE A COPY. 0 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by .. Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of,,a,Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk;County;New.York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant'agrees to comply with all applicable laws,ordinances;building code, housing code and regulations and to admit authorized inspectors on premises and in building(s).for necessary inspections.False statements made liereirt are punishable as a Class A.misdemeanor pursuant to Section 210.45 of the New York state Penal Law. Application Submitted By(print name):GreenLogic LLC EAuthorrized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this n, n day of ,20 Notary Public BARBARA A CASCIOTTA Public-State of PROPERTY OWNER AUTHORIZATION Notary No.01CA4894969WYork (Where the applicant is not the owner) CualiNedIn Suffolk County Commission Explres May 11,2027 Stephen Laddy residing at 3280 Wunneweta Road Cutchogue, NY 11935 GreenLogic LLC do hereby authorize to apply on my behal the wn S uild.ing Department for ap val as described herein. wne `Ognatjfied J SICA P MciVULTY nntp NOTARY PUBLIC,STATE OF NEW YORK PrA Owner's Name Registration No.01MC6392623 Qualified in Suffolk County' '` ,, My Commission Expires g11fFUlKc BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box 1179 N pry Southold, New York 11971-0959 _V Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCcDsoutholdtownn\/.gov — seand(c southoldtownn .qov APPLICATION FOR,ELECTRICAL INSPECTIO ELECTRICIAN INFORMATION (All Information Required) Date: 6/7/2023 Company Name: GreenLogic LLCM Name: Robert Skypala, License No.: 43858-ME email: Barbara Greenlogic. m Phone No: 631-771-5152 ®lcrequest an email copy o e ' ' Address.: 97 North Sea Road Southampton, NY 11968 i JOB SITE INFORMATION (All Information Required) Name: Stephen Laddy Address: 3280 Wunneweta Road, Cutchogue, NY Cross Street: Phone No.: 347-258-8642 Bldg.Permit#: 13 email: sladdy923@gmail.com Tax Map District: - 1000 Section: 111 Block: 11 Lot: 30 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (33) SunPower SPR-M425-H-AC panels Et (33) Enphase IQ7HS micro inverters (1) SunPower PVS6 monitor System Size: 14.025KW I Check All That Apply: Is job ready for inspection?: ❑YES ❑✓ NO ❑Rough In OFinal Do you need a Temp Certificate?: DYES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals 01 02 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION P� 6 Electrical Inspection Form 2020.xlsx V� �, I ()5 0 INX PO .. ,"r 1JJ i,sa so' W t TAX.LOT 19 N5f•57'.YD"£ _ �( �i.:r'�..._.___..___.....,_._-.—_�_.....s._.�.��0,G7' _ �f ,' t.r ;;':_ V,, o,.xx y. a t•:'r, ,u. 1. -', ,P 77 ,IE' ht TAX LOT 3N rr r` ✓r �y+ �( s, JJ _ C�PAr IX ."', �4 � /✓r { O - . Ur 400- `f ''' C {flu it 0 GRAPHIC SCALE WAW.JIIED TO: ca 1 W 1 Eri} rwt GREENLOGICO ENERGY June 7, 2023 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Stephen Laddy 3280 Wunnewata Road Cutchogue, NY 1000-111-11-30 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, MaJaw eA6ck*A Barbara Casciotta Account Manager Barbara@Greenlogic.com GREENb§JLg7 JC5-1nv6WgJ-?gic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd., #106 Southampton, NY 11968 Rosyln Heights, NY 11577 GREENLOGIC° ENERGY April 3, 2024 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Project Info: Building Permit No. 49473 Stephen Laddy 3280 Wunneweta Road Cutchogue, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy after inspection? Please let me know if you have any questions about the installation. Sincerely, 53avac m ewcckwa Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC•www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S.Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 NIA 'K Y x Suffolk County Executive's Office of Consumer Affairs &1V VETERANS MEMORIAL HIGHWAY HAUPPAUGE, NEWYORK 11788 "PI t DATE ISSUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY Home Improvement Contractor License This is to certifv that MARC A CLEJAN doing business as GREEN LOGIC LLC having fim-lished the requirements set forthin accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suff olk, State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses NOT VALID WITHOUT DIEPARTMENTAL SEAL AND A CURRENT CONSUNJER AFFAIRS 3, ID CARD Director ................. Suffolk County Execu. tzve s Offic e o Consumer ' .f Affairs � VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 i DATE ISSUED: 12/10/2007 No. 43858-ME SUFFOLK COUNTY Master Electrician License This is to certify that doing business as ROBERT J SKYPALA havin GREENLOGIC LLC g given satisfactory evidence of competency, is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws, rules and regulations of the County of Suffolk, State of New York. Additional Businesses NOT VALID WITHOUT I � DEPARTMENTAL SEAL r AND A'CURRENT CONSUMER AFFAIRS I1)CARD ' I IDirector Rum r NEW Workers' CERTIFICATE OF YORK STATE Compensation BoardNYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Greenlogic LLC (631)771-5152 97 North Sea Rd 1 c.NYS Unemployment Insurance Employer Registration Number of Suite 3 Insured South Hampton, NY 11968 Work Location of Insured(Only required if coverage is specifically limited to 1d. Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up.Policy) Number 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) United Wisconsin Insurance Company 3b.Policy Number of Entity Listed in Box"'Ia" TOWN OF SOUTHOLD WC605-00090-023-SZ BUILDING DEPARTMENT 53095 ROUTE 25 3c.Policy effective period SOUTHOLD, NY 11971 01/01/2023 to 01/01/2024 3d.The Proprietor,Partners or Executive Officers are ❑ Included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above.in box"1 a"for workers' compensation under the New York State Workers' Compensation Law.(To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". ' The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate'. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.`This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify'that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Alicia Christiansen (Print name of authorized representative or licensed agent of insurance carrier) Approved by: (Signature) (Date) Title: Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 941-306-3077 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov P4m-�-Pntdd -- - ----- --- ---- !"W EOUI;".,NT----._. __. --------� EXISTING SERVICE (TYPICAL S1V—Ebl SCHEMATA,, 120/240, 1 PH, 3W FlNAL INSTALLATIOP`MAY VARY, REQUIRES LM "U AND UTILTTY APR X) ! PV-SA-1 A 30C', KVv ri . . . AC-CMB-1 N 2 AC-COMBINER . 'L (PV ONLY) ( ,8 TYP. PV ARRAY �II '1C-DSC- .TYP. (4) CIRCUITS Ae SWITCH) ' I A a N PV-SA-4 A I BKR-1 • • • I 15Ur • • • 2 I BKR—N MAIN \ _�MAIN A �B N TYPICAL PV MODULE WITH I BKR—M 70A INTEGRAL DC/AC INVERTER II I � � II N j I PM-1 ECC N r�,,, EGC EGC I I I i AC DISTRIBUTION I AC DISTRIBUTION I I I MAIN C/T NEW EGC I I I I ---L-- #6CU MIN.-l- - T-- —� — —IRREVERSIBLE BOND, TYP. —`— � I EXISTINGIGEC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Laddy, Stephen GREENLOGIC0 3280 Wu n neweta Road Cutchogue, NY 11935 ._ RGY 2.) REVISED TO REFLECT ASBUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 1 of 4 Drawing No- LDDY-3LD2A Revision- 2 Revised- 1/23/2024 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 12.672 (PV) TOTAL PV KW RATING: (DC POWER) 14.025 (PV) J- CITY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-M425-H-AC 33 PV MODULE: 425 W DC(NOMINAL), EACH ENPHASE BRAND, MODEL: IQ7HS-66-M-US 33 PV INVERTER: (INTEGRAL TO MODULE) 384 VA, 1.60 A, 240V AC, EACH REVISIONS Laddy, Stephen G R E E N L®G IC® 3280 Wu n neweta Road Cutcho ue, NY 11935 ENERGY 2.) REVISED TO REFLECT ASBUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 2 of 4 Drawing No: LDDY-3LD2A Revision: 2 Revised: 1/23/2024 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 8-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-M425-H-AC, 1-CIRCUIT OF 9-MODULES PM-1 PRODUCTION MONITOR SUNPOWER PVS-6 AC-CMB-1 AC COMBINER PANEL, CRITICAL LOADS 250V, 100A, NEMA- 1-PH, 3-WIRE, MAIN-LUG BKR-1...BKR-4 CIRCUIT BREAKER, PV-SA-1...PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-M CIRCUIT BREAKER, PM-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 25OV, SERVICE RATED,CIRCUIT BREAKER RATING: 70A Laddy, Stephen REVISIONS 3280 Wunneweta Road C�REEIVLOGIC Cutcho ue, NY 11935 ENERGY 9 2.) REVISED TO REFLECT ASBUILT CONFIGURATION ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 3 of 4 Drawing No: LDDY-3LD2A Revision: 2 Revised: 1/23/2024 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3,072 WATTS 211-264 VAC 12.80 A AC 240 V,AC PV-SA-2 3,072 WATTS 211-264 VAC 12.80 A AC 240 V,AC PV-SA-3 3,072 WATTS 211-264 VAC 12.80 A AC 240 V,AC PV-SA-4 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 10 / 10 B THWN-2 1" PVC-40 4 / C THWN-2 1" PVC-40 D THWN-2 3/4" EMT 12 / 12 1,)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DEBATING FACTORS. 2.)ELECTRICAL CONDUIT TO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT PV ARRAY GROUNDING CONDUCTOR TO BE#6 COPPER,MINIMUM PROPOSED ELECTRICAL LOADS Laddy, Stephen REVISIONS 3280 Wunneweta Road GREENLO ENERIC - Cutcho ue, NY 11935 ���RGY 2.) REVISED TO REFLECT ASBUILT CONFIGURATION ELIMINATING THE dOST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 4 of 4 Drawing No: LDDY-3LD2A Revision: 2 Revised: 1/23/2024 r t J A M E S J. S TOUT A RCHITECT & ASSOC . 2 G RE LANE EAST NaRTSP ORT N. Y. 631 - 8 58 938. 8 COMPLY WITH ALL CODES OF Letter of Certification NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF May 12, 2023 eat at 191 BOARD RE: Laddy Residence 3280 Wunneweta Road SO� {9EBiR{} EES Cutchogue, NY 11935 ',NYS,DEC To whom it may concern: I,James J.Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and complies with the 140-mph wind design load as per 2020 Residential code of NYS (RCNYS),2020 Energy conservation construction code of NYS(ECCCNYS),the Long Island Unified Solar Permit Initiative(LIUSPI)and the ASCE 7-16. The existing 2"x 12"@ 16"o.c. roof rafters will provide the required support. Thank you for your understanding in this matter. James J. Stout Architect AP R• VED AS NOTED DAT EE BY: NOTIFY,;'BUILDING DEPARTMENT AT 5-1862, BEAM TO 4 PM FOR THE FOLLOWING.INSPECTIONS: 1. FOUNDATION,.- TWO REQUIRED FOR POURED_ COtvGRETE' _ y 2. ROUGH -'FRAMING & PLUMBING r 3. INSULATION Z. sc 4. FINAL .- CON.`'TFL!CTICN MUST ' 02,1 33 �� BE .'COMPLETE F E� ALL CONSTRUCTK_-:1•1 SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR )CU DESIGN OR CONSTRUCTION ERRORS. , A •CY r�►' ' add. :. J:, FORT ELECTRICAL ,. INSPECTION REQUIRED G EENLOGIC" . ENERGY GreenLogic,LLC.Approved Laddy,Stephen 3280 Wunneweta Road Cutchogue,NY 11935 Surface#A: Total System Size:14.025kW Array Size:14.025kW 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:240' Pitch:Monitoriri ng System: SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.T'X 40.6' Array:3T 10 3/8"X 18'6 9/16" Surface:63'X 21',V Magic#:Invisimount Legend: ® 33 SunPower425W Panels ® SunPower Invisimount Rai • 51 Iron Ridge Flash Foot 8 2x12"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.54psf Engineer/Architect Seal: AR�� �5 ST A i` T9T 021633 �OQ i OF N�� i Drawn By:MMB Drawing#1 of 5 Date:5/10/2023 REV:B Drawing Scale:1/8"=1.9 C+GRE-ENLOGICG E fV E F2 GY- G,reenLogic,LLC Approved Laddy,Stephen 3280 Wunneweta Road Cutchogue,NY 11935 Surface#A: Total System Size:14.025kW Array Size:14.025kW 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:240' Pitch:7" Monitoring System: SunPower ) Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:37'10 3/8"X 18'6 9/16" Surface:6Y X 21'4" Magic#:Invisimount Legend: ® 33 SunPower 425W Panels ® SunPower Invisimount Rail • 51 Iron Ridge Flash Foot 1 2x1 T Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.54psf Engineer/Architect Seal: P AR� D A 021633 yOQ f OF NEK Drawn By:MMB Drawing#2 of 5 Date:5/10/2023 REV.B Drawing Scale:1/8"=1.9 GREENW.GICO ENERGY GreenLogic,LLC Approved Laddy,Stephen 3280 Wunneweta Road Cutchogue,NY 11935 Surface#A: Total System Size:14.025kW Array Size:14.025kW 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:240° Pitch: Monitoriri ng System: SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Panel:73.T'X 40.6" 3 4 Array:-3T 10 3/8"X 1 V 6 9/16" Surface:63'X 21'4" Magic#:Invisimount L end: ® 33 SunPower425W Panels 2 4 SunPower Invisimount Rail • 51 Iron Ridge Flash Foot 2 8 2x12"Douglas Fir Rafter 16"O.C. Notes: 1 4 Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.54psf Engineer/Architect Seal: ARI 021633 yp2 OF N'S'14 i t t v� Drawn By-MMB I Drawing#3 of 5 Date:5/10/2023 REV.B Drawing Scale:1/8"=1.V No Vent Pipes Will Be Covered By The Solar Array GREENLOGICe ENERGY Legend: _ GreenLogic,LLC Approved AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge Laddy,Stephen per R202 definitions per R324.6.1 as per R324.6.2.1 3280 Wunneweta Road Cutchogue,NY 11935 Total System Size:14.025kW 1 circuft of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:240' Monitoring System: SunPower Panel/Array Specifications: Meter Panel:SPR-M425-H AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Magic#:Invisimount t_ errd• ® 33 SunPower 425W Panels ® SunPower Invisimount Rail • 51 Iron Ridge Flash Foot 2 11 2x12"Douglas Fir Rafter 16"O.C. Notes: AR Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.54psf 33S nPower Engineer/Architect Seal; A� A� JAN Panels V� AR x1xjx \yQ��S Nk ST -k } 0z1633 AOQ ' ! OF NE`N 1 Drawn By:MMB I Drawing#4 of 5 Date-5/10/2023 REV:B Drawing Scale:1/16"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved Laddy,Stephen 3280 Wunnevmta Road Cutchogue,NY 11935 Total System Size:14.025kW I circuit of 8 on a 20A breaker I circuit of 8 on a 20A breaker I circuit of 8 on a 20A breaker I circuit of 9 on a 20A breaker ------ Azimuth:240* Material List QtV. Rail Material List oty. Monitoring System: ----- -- SunPower Panel/Array Specifications: Panel:SPR-M425-H-AC Racking:SunPower Invisimount Cast Aluminum MountingBlockw/Black Aluminum Flashing 51 Panel:73.r,X 40.6' Magic*Invisimount 5116"A.75"Hex-Head Lag Screw 51 5/16"x1.25lender Washer 51 Legend: 33 SunPower425W Panels SunPower Invisimount Rail 0 51 Iran Ridge as Foot 2 2x1 2'Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:i Height above Roof Surface:4!' Materials Used:Iron Ridge,SunPower Added Roof load of PV System:2.54psf Engineer/Architect Sea[: A;? 021633 yOe OF Drawn By:MMB Drawing#5 of 5 Date:5/1012023 1 REV.B. Drawing Scale:1/16"=1.0' f, ------=------ NEW EQUIPMENT——-------------=----- EXISTING SERVICE PV—SA-1 A AC—COMBINER PANEL 120/240, 1 PH, 3W rgn • • AC—CMB-1 B Inl • • • 1 (PV LOADS ONLY) I V 200A KWH FM PV—SA-2 A j I • • • I A B N I r • AC—DSC-1 N ---_ 2 1 — --- i BKR AC DISCONNECT I � I I TT BKR-2 PV—SA-3 A I I � N • � • 2 1 BKR-3 � (" � J J ��MAIN III A B N i III BKR-4 FUSED I PV—SA-4 A III I . N • • • 2 1 i t IEGc i 1111 I i N TYPICAL PV MODULE WITH IIII I INTEGRAL DC/AC INVERTER IIII EGC �EG IIII IIII EXISTING AC PANEII EXISTING I I LLJ1------------ -----------------�—=— GEC 7------ 14.025kW DC 12.672kW AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS. paddy, Stephen S�AR�h G_R E E N LOG IC 3280 Wunneweta Road �",p",� ST Cutchogue, NY 11935 ENERGY 'OF ENERGY ELIMINATING THE COST 1.) INITIAL SUBMITTAL WITH APPLICATION -v 021e3jyoer OF NEj Page 1 of 3 Drawing No: Laddy-3LD1 Revision: 1 �' Revised: 6/28/22 l EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-M-425-H-AC ENPHASE IQ7HS, 1-CIRCUIT.OF 9-MODULES PV-SA-2 PV SUB-ARRAY SPR-M-425-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-3 PV SUB-ARRAY SPR-M-425-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-4 PV SUB-ARRAY SPR-M=425-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES ELECTRICAL LOAD SUMMARY AC Cl RCU ITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL " RANGE CURRENT PV-SA-1 3825 WATTS 211-264 VAC 15.55 A AC 240 V, AC PV-SA-2 3400 WATTS 211-264 VAC 13.82 A AC 240 V, AC PV-SA-3 3400 WATTS 211-264 VAC 13.82 A AC 240 V,AC PV-SA-4 3400 WATTS 211-264 VAC 13.82A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Laddy, Stephen �,5��5 ST GREENLOGIC° 3280 Wunneweta Road �Cutchogue, NY 11935 ENERGY 9T zi633yoer 'ELIMINATING THE COST OFTN_ERGY 1.) INITIAL SUBMITTAL WITH APPLICATION OF NEN i -Page 2 of 3 Drawing No: Laddy-3LD1 Revision: 1 Revised: 6/28/22. EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL~ 25OV, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 - MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 25OV, 100A, NEMA-1, FUSED; FUSE RATING: 100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. ,/ EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 4 / 6 C THWN-2 2" EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST-FOR SITE CONDITIONS. 3:) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS a .A;? Laddy, Stephen 5`� ST GREEN LOGIC® 5 3280 Wunneweta Road ENERGY Cutchogue, NY 11935 02163'S oer ELIMINATING THE COST OF ENERGY . 1.) INITIAL SUBMITTAL WITH APPLICATION ''' OF NENy Page 3 of 3 Drawing No: Laddy-3LD1 Revision: 1 U Revised: 6/28/22 SUMP WER° 420-44OW Residential AC Module �`-- SunPower""' Maxeon-"Technology - Built specifically for use with the SunPower Equinoxc system,the only fully integrated solar solution designed,engineered,and warranted by one company. :. UXI -1 Highest Power AC Density Available. The patented,solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest efficiency AC solar panel available! L:-.�j A M c. _ E mr ui�: larger .. ..e;. i. -Pant :'Equinox Solat.., ystelm Corripatible`with: Highest Lifetime Energy and Savings mySunPowerT"^ monitoring. ; Designed to deliver 60% more energy over 25 years in Seamless aesthetics; ' : real-world conditions like partial shade and high temperatures? .... .... . i .; 12M, 1 I Up to 604. More 1 40 u gp;5 Lifetirne t' W ij1 =rergy N l°FktorS/Antege ted ears of Operation '`Microinverter" Highest=power"integrated Best Reliability, Best Warranty AC module.in solar.; With more than 42.6 million and 15 GW modules deployed around "®'Engineer'ed.and calibrated `;° the world,SunPower technology is proven to last.That's why we %by Sun Power for;Sun Power. ; ` "< stand behind our module and microinverter with the industry's AC modules best 25-year Combined Power and Product Warranty. M-Series: M440 M435 M430 ( M425 M420 SunPower° Residential AC .. Inverter Model:Type H(Enphase IQ7H5) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 Nom.(L-L)Voltage/Range'(V) 240/21 1-264 208/183-229 Max.Continuous Output Current(Arms) 1.60 1.77 Max.Units per 20 A(L-L)Branch Circuit-' 10 9 CEC Weighted Efficiency 97.0% 96.5% j Nom.Frequency 60 Hz Extended Frequency Range 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A Tins I -...._._ ._........ .---.. -- --- -- - -- 1 Overvoltage Class AC Port III I AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor(adjustable) 0.85(inductive)!0.85(capacitive) SPR-R•1440- SPR-ib1.135- SPR-PA430- SPR-M425- SPR-1,1420- I •25-year IlrlllCed ppWBY two r.ant H AC H-AC H-AC H-AC H-AC Warranties 25-year limited product warrant --- -- Nom.Pavers(Pnom)W 440 435 430 425 420 1UL 1741/IEEE-1547 - +5/-0°b - ........__...---- UL 1 741 AC Module(Type 2 fire rated) Power Tolerance __-__ _____ UL 62109-1/IEC 62109-2 -- -. Module Efficiency 22.8% 22.5% 22.3% 22.0% 21.7% FCC Part 15 Class B ICES-0003 Class B Temp.Coef.(Power) -0.29%/0 C CAN/CSA-C22.2 NO.107.1-01 Shade Tolerance Integrated module-level max.power point track CA Rule 21(UL 1741 SA)4ing i (includes VoltNar and Reactive Power Priority) : Certifications •UL Listed PV Rapid Shutdown Equipment' ; • per • • • and Operating Temp. -40'F to+185'F(-40°C to+851 C) Compliance Enables installation in accordance with: NEC 690.6(AC module) Max.Ambient Temp. 122°F(50°C) NEC 690.12 Rapid Shutdown(inside and outside the; Wind:125 psi,6000 Pa,611 kg/m2 back array) Max.Test Load Snow:187 psf,9000 Pa,917 kg/m2 front NEC 690.15 AC Connectors,690.33(A)-(E)(1) Max.Design Load Wind:75 psf,3600 Pa,367 kg/m'back When used with AC module Q Cables and accessories! Snow:125 psf.6000 Pa,611 kg/m2 front (UL 6703 and UL 2238)': I Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) •Rated for load break disconnect PID Test 1000 V:IEC 62804 0. - -- -- ,pa anica Solar Cells 66 Maxecn Gen 6 • • • Front Glass High-transmiss;on tempered glass with anti-reflective coating I Modules per pallet 25 Environmental Rating Outdoor rated --- ---- -- - ----- 1 Packaging box dimensions 1915*1072*1220 mm I Frame Class 1 black anodized(highest AAMA rating) Weight 48 Ibs(21.8 kg) I Pallet gross weight 590 kg i Recommended Max. I Pallets per container 32 Module Spacing 1.3 in.(33 min) Net weight per container 18,880 kg 73.,in *Based on datasheet review of weasites of tap 20 manufacturers per% ...................._..._toad Mackenzie US?V Leaderboard Q3 2021. V872 mm1 FRAME PROFILE 1 Maxeon 435 W,22.5%efficient,compared to a conventional Panel on same-sized arrays(260 W,16%. efficient, .....j.....i "U ap m prcx.1.6 -),7.9%more energy per watt(based on PVSyst pan files for avg US climate),0.5%/yr slower degradation rate(lordan,et.al."Robust PV Degradation Methodology and Application:'PVSC'_018). Grounding Holes 2 Voltage range can be extended beyond nominal if required by the utility. ! s 3 Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. ry w-•A- 4 Factory set to EEE 1547 --2014 default seu rgs.CA Rule 21 default settings orcfile set during commissioning. v o J 5 Standard Test Conditions(1030 w/m'irradiance.AM 15,2V0.All DC voltage is'ull_d contained within the module. (�)Long Side:i3 in f32 min) 6 UL Listed as PVRSE and conforms with NEC 2014 and NK 2017 690.12;and C22.i-2015 Ruse 64-218 Rapid `!i Short Side.0.91n(24mm) Shutdown of PV Systems,for AC and DC conductors;when ir:_tal:ed according to manufacturer's instructions. 7 Please read the safety and installation instructions for more information regarding load ratings and ---. mounting corfiguradons. Please read the safetv and instailation instructions for details See vrrnv.sunpower.com!company for more reference information. Snecifications included in this datasheet are subject to change without novice. c xnr 02021 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPO'WER'ogo,SUNPOW'ER EQUINOX Q' w is' M 539973 Rev B/LTR_EN and MYSUNPOWIER are trademar'Ics or registered trademarks of SunPower Corporation in the U.S.MAXEON is a LISTED eaww registered:radernarkofMaxeon Solar Technologies,Lid Formore information visit www.maxeoncom/legal. nn.d.i.Fi,.P.d.rm.o TyF.2 Publication Date: October 2021 flw .....w:«....—.., .,.m.ate»-�.+nma... ....d.� • '- ;l-sE.: ap Simple and Fast installation _- __ Integrated module-to-rail grounding Pre-assembled mid and end cramps i...evicating mid damp for eas;'.placernenr. . Mid clamp width facilitates consistent,even :� .�-�. � .tit,•;- � �`" module spacing Simple,pre drilled rail s,.ilice - LiL 2703 Listed:nt:grated grounding Flexible Design' — Addresses nearly all slowed res;denriai roofs t Design in landscape and'por raii. nails erial::le easy obstacle managerneri. = Custot-ner=.F'referred'Aesthetics . " '° i:;rodul'e and#" nicunting aesthetics -Best-in class syscem aesthetics Elegant Simplicity Premium,lovj-pro;le design Biack anodized components SunPower5 InvisiMountTl,' is a SunPower-designed Hidden mid damps and end damps rail-based mounting system. The InvisiMount system and capped flush rails .; : .. addresses residential sloped roofs and combines faster Part of,Superior System installation time, design flexibility, and superior aesthetics. Built TO use wit i Sur,f�etier DC-and AC modules The InvisiMount product was specifically envisioned and Best-in-class system reliability and aesthetics Combine withSunPower nodules and engineered to pair with SUnPower modules. The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. sunpower.com n AM 71 sl wn dule* End Clamp and Rail VlodLIIe4'/Mid Clamp and Rai' Mo Mid(I End Clamp Rail&Rall Splice Grot Ind Lug Assembly End Cap X'. R"5 MINE% V,OWN Temperature C to 90°C(-40- to 194-F) i Component IVaterial VvfeighT .............................................................. 3000 Pa ....... Max.Load(L.RFD) 5CrIO Pa clownforceuplift Mid Clamp Black oxide stainless steel Alsi 304 63 02.�oz) ............. ..................... ................................................... End Clamp Black af,.oclized aluminum alloy 6061T6 110 g(3,88 07) Rail Black anodized alurninurn alloy 8-30.`,/n)(9 oz1ft) M. Rail Splice Al,Iminurn alloy 6005 TS an- gim(9 oz','ft) 25-year product warranty ......... ... . ............ ............................ Warranties Ground Lug 304stainiess 106.5 g/in(3.75 oz) 5-yearfinishwarranity Assembly (A2-70 bolt;tin-plated copper lug) . . ...................... .................................................................. .......................... ............................................... ..............I.................. End ......nd Cap Black acetal fPOM)copolymer �g(e.37 7).. U11-27031-Isted Certifications Class A Fire.Rated ............... —-------- Compos:don Shingle Rafter Autachmen'. Compos-ron Shingle Roof Decking ActachrrienI Application Curved and Plat TOe Roof Attachment i Universal Interface for Other Roof Attachments 1 Refer to roof attachment hardware manufacrurers documentation. ............................................................. ........................................................................................................................... ................. ............................................ ....................................- --MG d Ule frarrip.that s compatible with the:I Inv:Si Nd,DU nt system required for ha r�'*,are i Into opera bility. -D 7 -R,6),. -015 Suntimver Coi oration. All;Rights Resented.SUNPOWI: cSUNPOWIER iopo—w d)INIVISIVIOUN'Tarc u zdernarks or registered sunpmver.corn tiademarksofS(jrp,)werCorperat.,)!i. All other trademarks are the pioperty of their respective Specifications included in this datashec.r are subject to change withou'notice. Document#509506 RevC S NPOWER"u •> ,t 3,y; ..mac°:,° r .. ., .E•, %*�,.. w ya w . .. .., .. -. ..,,. 10 49 improve Support;' Reduce'Maintenance Costs SunPovver EnergyLink—Plug-and-Play Installation An intuitive monitoring ir.ebsitc eriabl s you.to: This complete solution for residential and commercial monitoring and See a vhtlul map �(CUsromer sites" control InclutieS the SunPower'"Pv S; Pervisor 6(PVS6)which improves i'2eM0IC-l`4 manage hundreds of s'tes- tie instal'adon process,overall system reliability';and CustorTler Receive elective system reports experiertcc. locate ystern issueS L:r,d rerrl0tely'diagnose �o,npact t:otpril t for improved aesthetics ')iagnose issues on:.line. Robust Cloud CoI nr;ectivliy and con'tprehensive local connectivity Grill tit;s>dn for the sank of ir7di'•.ir't:al devices Flexible configuration of devices during Installation r �.. Consumption rneter'ng Revenue-grade production ri7eterir:. (pen-ding)� Web-based commissioning Remote diagnostics of PVS6 and inverters Durable UL Type 3 enclosure reduces mantenal ice Costs - •- Easy integration with SunPo,Frer e6oS Add Value for Customers P Robust Cloud Connectivity Mth rihe SunPower Monitoring System customers can: Multiple options to rnaintain optimal t ,•_ ieP.,what ihP.'r olarSystcrn prCiaUCe e C �, ._,. connect, . kb i1, k clay,month,or year_ N Hardwired Ethernet optimize their solar:investment and save on i,'i-Fi i. energy expenses ' • < Cellular backup See their energy use and est'mated bil!ss':.ings { See their solar systern's performance using the SunPovder.rnonlcoringyvebsite or mobilea,pp �. f v A a¢tn - I 1 11 Ig 1!�� I SunPower Monitoring Websites MG SunPower AC Modules _Lnrlrsl�GH�E����III.[Iit . i €. IS Multiple communication options include Ethernet,;Wi-Fi,and cellular. AIRe.. Number of SunPower AC modules 85 t'einperature -22°F to+140°F(-30°C to+60'Q supported per P'JS6 Flumidty(maximum) 9595,non-condensing High-speed Internet access via accessible Internet access router or switch Power 100-240 VAC_(I..-N),1>0 o'(;0 FIz • 208 VAC(L-Lin 3-phase).60 Hz •M I'.. -485 I:verters and meters • one channel of revenue-grade production metering Integrated Ivtetenng , Two channels of cons!�mption metering Weight5.5 Ibs(2.5 kol ....................._............................._.._._.--........_..........................-..................................... ..............__...__.._..._.._..............._.__.._........._.........................................._. Ethernet ^: LAN(or optional'HAN)port Dimensions 11.8 x 8.0 x 4.2 in.(30.5 x 2.0.5 x 10.8 cm) PLC PCC for SunPower AC modules Enclosure rating UL50E Type 3R Vdi-FI 802.11 blgr`n 2.4 GHz and 5 GHz Cellular ---- LTF..Cat-M113G t.MTS zigBee I_EE 802.15.4 MAC,2.4(:,I-iz ISM hand Data Storage 60 days .............-.,..........................._... -...._..............----... -._...................................._._.._ Customer site m�aI1�L�r�ts.��np2�tiet�c.Qr..t? Upgrac#es Aui:omat!c iirrnware upgrades Partner site pvsmgmr.us.sunoow-er.com Browsers Firefox,Safari,and Chrome Mobile devices iPhone',iPadl,and Android'" -.r Customer app 1.Create account online at:monitor.us.sunpoover,com. ° 2..on a motile device,download the SunPower I`'lonitoring Warranty 10-year Limited Warranty app from Apple App Store"or Google Play?'store. 3.Sign in using account email and password. Certifications UL,cUL,CE,UL 61010--11 aC nd-2,FCC Part 15(Class 8) C@US LEM FCC ID:YAW529027 £503346 �530536 RdVC POWE Ft SUN POWE "Ill U, N POWT �'r