Loading...
HomeMy WebLinkAbout49894-Z OSUFfOl,f0, Town of Southold o�y 5/28/2024 P.O.Box 1179 o • g_ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45219 Date: 5/28/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 4980 Pequash Ave. Cutchogue SCTM#: 473889 Sec/Block/Lot: 110.-3-26 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/3/2023 pursuant to which Building Permit No. 49894 dated 10/16/2023 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: generator as applied for. The certificate is issued to Lockwood,Mark&Robin of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49894 12/21/2023 PLUMBERS CERTIFICATION DATED i th ri e Signature fF ant jr. TOWN OF SOUTHOLD �Oay� BUILDING DEPARTMENT x TOWN CLERK'S OFFICE Cn oy • ��, SOUTHOLD, NY col J BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49894 Date: 10/16/2023 Permission is hereby granted to: Lockwood, Mark 270 W 17th St Apt 2L New York, NY 10011 To: install generator as applied for. .At premises located at: - 4980 Peguash Ave. Cutchogue SCTM # 473889 Sec/Block/Lot# 110.-3-26 Pursuant to application dated 10/3/2023 and approved by the Building Inspector. To expire on 4/16/2025. Fees: ACCESSORY $125.00 ELECTRIC $100.00 L CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector oF so�ryol Town Hall Annex O Telephone(631)765-1802 54375 Main Road P.O.Box 1179 a sean.devlin(&-town.southold.nv.us Southold,NY 11971-0959 Cowl BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mark Lockwood Address: 4980 Pequash Ave City:Cutchogue st: NY zip: 11935 Building Permit#: 49894 section: 110 Block: 3 Lot: 26 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Platinum East Electric License No: 34091 ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 22 kW Generac Generator w/ 200A Whole House Transfer Switch Notes: Generator Inspector Signature: Date: December 21, 2023 S. Devlin-Cert Electrical Compliance Form ii 3s .� a� I � 1 i , �r 1111911011 WEB9ITE SUPERIOgEE COM DELTA 1 n Is til � � III II I II I I I'III I I'li�II"tll'II 09,9175177 /Oppi "_#Ake- _ � ...�..__..�.. i I■ 1 .-FOCUS RXRe �r'M/S[IA 110Y]w(eltr IA=151s0{�-� �Nil IIN11:BMI111111tlbN{IIIY P LY+O ISI NO apwER a'JTRORITV �NJII I�Mfllle II'. • This Bullding Is eq.1pped.1 h sn Interconnected Electric Power •- Production Source soura_rro:m.err cnrrc {Nv rTn.ru.k: oer �v�t niawa:Nrlr sr., W ur nxrsu.— oe.I.a. � 1 � e v� IELD INSPECTION REPORT DATE COMMENTS o ZA� FOUNDATION (1ST) -Jszo- ------------------------------------- FOUNDATION (2ND O ROUGH FRAMING& PLUMBING INSULATION PER N.Y. STATE ENERGY CODE v FINAL ADDITIONAL COMMENTS Q)P !W i b6q5j, -- - �y_ �. �s-c ------------------ - - - -�_ g 0 C) o�oSUFFoc,t�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT s� Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny. oovv Date Received APPLICATION FOR BUILDING PERMIT Office Use Only D i7 �� PERMIT NO. 4AO� Building Inspector: �_- D J OCT 3 2023 -� Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an BUIL DENG DEPT. Owner's Authoriiation form(Page 2)shall be completed. I �S�'Ra 4;'F F rt;Tn Date: September 26, 2023 OWNER(S)OF PROPERTY: Name: Mark and Robin Lockwood SCTM# 1000-110.-3-26 Project Address: 4980 Pequash Ave, Cutchogue, NY 11935 Phone#:(917) 449-4501 (M) (917) 312-1972 (R) Email:rparkslockwood@gmail.com, malockwood@deloitte.com Mailing Address: 4980 Pequash Avenue, Cutchogue NY 11935 CONTACT PERSON: Name: Robin Lockwood Mailing Address: 4980 Pequash Avenue, Cutchogue, NY 11935 Phone#: 917-312-1972 Email: meryl@mkarchitect.com DESIGN PROFESSIONAL INFORMATION: Name: Meryl Kramer Architect, PC Mailing Address: PO Box 1600, 260 Hortons Lane, Southold, NY 11971 Phone#: 631-477-8736 Email: Meryl@ mkarchitect.com CONTRACTOR INFORMATION: Name: North Fork Woodworks, Inc. Mailing Address: PO Box 1407, 810 Traveler Street, Southold, NY 11971 Phone#: 631-298-7900 Email: rachel@nfwoodworks.com DESCRIPTION OF PROPOSED CONSTRUCTION. ❑New Structure ❑Addition ❑Alteration ❑Repair Demolition Estimated Cost of Project: ElOtherGenerator $1 Million Will the lot be re-graded? --Yes El No Will excess fill be removed from premises? ZYes ONO 1 • i PROPERTY INFORMATION Existing use of property: Single Family Residence Intended use of property:Single Fa i ily Residence Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R40 this property? ❑Yes ®No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The"owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are Punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Meryl Kramer Application Submitted y(print name): BAuthorized Agent ❑Owner Signature of Applicant: �(.�•�� Date:09/26/23 CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State of New York SS: No.01 BU6185050 Qualified in Suffolk County COUNTY OF Commission Expires April 14,2 D"j being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ��� 1��-�l ,20 D ) Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 g3fFDI/( BUILDING DEPARTMENT-Electrical Inspector COGyc TOWN,OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 N 2 o • Southold, New York 11971-0959 'y4j o� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrOsoutholdtownny.gov- seand southoldtownny,Qov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 9/27/23 Company Name: Platinum East Electric Electrician's Name: Keith VonEiff License No.: #34091-ME Elec. email: Platinumeast1@yahoo.com Elec. Phone No: 631-765-9424 ❑1 request an email copy of Certificate of Compliance Elec. Address.: 1320 Kennys Road, Southold JOB SITE INFORMATION (All Information Required) Name: Mark and Robin Lockwood Address: 4980 Pequash Avenue, Cutchogue, NY 11935 Cross Street: Fleetwood Road Phone No.: 917-312-1972 Bldg.Permit#:___i+q! email: Tax Map District: 1000 Section: 110 Block: .-3 Lot: -26 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): - Relocate existing generator Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES❑ ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES❑ Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 2 R H Frame Pole Work done on Service? Y RN Additional Information: PAYMENT DUE WITH APPLICATION 1 �� � D i. 0 CT 2023 :.._. M E R Y L K R A M E R a r c h i t e c t TOWN 260 HORTONS LANE TRANSMITTAL POST OFFICE BOX 1 600 S O U T H O L D, N Y 1 1 9 7 1 AkAm Town of Southold Bldg Dept Via: Drop-off 6 3 1 4 7 7 - 8 7 3 6 Address 54375 Main Rd.,Southold,NY 11971 Date: September 28,2023 m k a r c h i t e c t c o m Re: Bldg Permit for Generator CC: WE ARE SENDING YOU x Attached ❑Under separate cover via the following items: ❑Shop drawings X Drawings ❑Specifications ❑Copy of letter ❑Samples COPIES DATE DESCRIPTION 1 9/26/2023 Application for Bldg Permit,Generator 1 9/27/2023 Application for Electrical Inspection 1 N/A Generac-Guardian Series,Generator 1 11/08/22 Site Plan 1 01.19/17 Survey THESE ARE TRANSMITTED as checked below: X For Approval ❑For your use ❑As Requested ❑ For review and comment REMARKS: LOCKWOOD RESIDENCE 4980 Fequash Avenue Cutchogue, New York marshal) poetzel LANDSCAPE ARCHITECTURE PROPOSED 30 SF OUTDOOR SHOWER NORTH FORK X (BY ARCH) 5175 Route 48 PROPOSED STEPPING PROPOSED R.R.TIE Mattituck,NY 11952 PROPOSED PROPOSED 43 SF STONE,TYP. RETAINING WALL I I RETAINING WALL, UNCOVERED POOL p ) TYP. EQUIPMENT (631 hone:PROPOSED RETAINING EXISTING PROPOSED EV I 209-2410 (BY ARCH) WALL+SLAB STEPS WALL CHARGING STATION fax: (631) 315-5000 (23.9J (23.79) (23.05) (22.52) (21.79) (20.86) 175.00' N 57°4 ' 0" E �} / email: mail@mplastudio.com 0 x�_x_ _ ` /�xxr�xr�x�/l�'Y O xOJ) -- -- N �\ \ \� O TIN 29.221 c a , v ` o (210 15) II \\ ARCHITECT: \ \ 6 � BIN 23.0� +B W 22.0 p * BS 25.75 I \ ` POOL EQUIP \ III BW - ; Meryl Kramer Architect I\\ TW33.0+ III i \jl \O ❑ \\\ TS2 .2 ❑ � ❑��❑❑��I-J ❑�) \ �BS24.1 \� \24.5 � \\ \� P.O.Box1600 r (2 ) x x 24. 25.67 \ PROP. \ 260 Hortons Lane �� I \ 24. p x `GRAVEL \ \ I (28.7 I he \ AC Ac LAJC AC `� \ Southold, NY 11971 n l�T � AREA N \ \ Office: (631) 477-8736 29.42 2�.22 27.72TIN TS ( 3.5) \ \ N \\ SURVEYOR: \ ��I I 26'.5 25.6 ,�, \ \ iW q +TW PROPOSED PROPOSED PROPOSED N \1 N `� \\ \\ Kenneth Woychuk LS \ w 31.12 ti N.Y.S. Licensed Land Surveyor \ \ \ 29.22 I WINDOW WELL GENERATOR-GRAVEL AREA \ \ \ BY ARCH. `� \ ` P.O. Box 153 `\ TIN \ �\ �\ i 'V� PROP. ( �� II ( ) PROPOSED R.R.-TIE Aquebogue, NY 11931 \\ 35.00 \ ON- 1 I x(25.37) RETAINING WALL, PROPOSE Office: (631) 298-1588 GRADE 1 I \\ ► 25.67 25.55 OIL+STONE PATIO 1 II PROPOSED PROP. DRIVEWAYII �, `� CIVIL ENGINEER: \\ \\ \\ \\ ,27.45 I PROPOSED GARAGE I' ON- \ SL Maresca &Associates 1 COVERED PATIO FFE:26.00 I GRADE \ �, 79.92' \ \ 188 West Montauk Highway-Suite E4 \ \ \ \ (BY ARCH.) MASONRY I �\ ,\ Hampton Bays, NY 11946 \ PROPOSED \ APRON \ \ w \ PLANTING -1' / I II � \\ \\ X \ 14'-0"X 36'-0" \\ \\ 1 . . Office: (631) 728-9480 \ c' \ SWIMMING POOL i i 1 27.5+ I 7S 2'6.06 (23J5)x \\ \ \ 2 5+ 3 P u� \ COPING ELEV \\ PROPOSED \\ �i � 1 ) 27. 8 +BS125.56 26.00 \� BW \ W \\ 31.29 \ ON-GRADE \ �i �� - i ,I + }�22.00 `\ PATIO rig i i� I (26.8)x I \\ r PROPOSED- PROPOSED (I \ \ PROPOSED COVERED I \ D RETAINING WALL, \ RETAINING WALL, Z LANDING+STEPS i TYP. I ` \ -i (BY ARCH.) \I \\ 1 BW \� Z i PROPOSED STEPPING II ` W \ \\ \ \\ p LA N T�N G + 27.75 �,TW 29.80 BW G) STONE,TYP. + +26.37 II \ \ \ \ \ \ \\ \ (31.07)x j�IN3L'12 �� i ` 0 I � III II x II SITE DATA: PROPOSED I I (2�.42) I +31l12 I, ; TS BS N RESIDENCE i II I, SCTM# 1000-110-3-26 29.12 + 26.62 PROPOSED I ' II I T Lot Area: 17,500 SF (or.4 acres) �\ � \ (BY ARCHITECT) I I -L COVERED PATIO FIFE:28.062 \\ \\ + + (BY ARCH.) _-- II PLANTING II TW 35.00 ` TW i \\ PROPOSED MASONRY BS I x(26'1) j (22'0)I x x(21.33) V) 32 80 \, II I \\ ON EDGE+SLAB STEPS 27.0 27.5+ I I I 1.3�x ( I I I NOTES: TW 31.12+ - I 'll\ ---- � PRO(OSED ON-GRADE I TIN \ \ \ - ------TS BS �� MASONRY PAD 26.00+ ` W 1. Existing conditions based on survey PROPOSED 27.5 + 26.5 �\ `� �`� 'ON-GRADE PROPOSED , prepared by Kenneth M.Woychuk Land PATIO, PROPOSED PROPOSED TEA,TYP. TS 26.00 ` \ SCREENED PORCH COVERED , Surveying dated 1/19/2017 and revised N FIFE: -------- PATIO �� ' I I l+ '-_I \ 9/10/2019. r 2. This drawingis for the purpose of \ 31,83 x \ �` �`\\ ! \\ LAWN \ ( ) \ \ \ -� obtaining permits only. NOT FOR \ \ �BY ARCH.) j I I I p p \� `---- - _ \\ I \` CONSTRUCTION. � � � � -\ \ \ � PROPOSED STEPS TW \ BS 27.0 27.5+ \\ \ \ , WITH HANDRAILII 26.00+ \� 3. Unauthorized alteration of this plan is a \ N `\ '� `I violation of NYS Education Law. <1 PLANTING BW27.00 Cl) i iW31�12 \ 3 0 27 \\ (25.22) x`PLANtING -_ Jw , \\\ \\ \ \\\ i ��\\aI w DATE REVISIONS o `� \\ `\ ` \ o j 09.06.22 ADD SETBACK DIMENSIONS BW ' - r n¢ FROM PROPOSED RESIDENCE `\N �`\ �`� \ \ \\ `\ `\ \I i 26.00 26.00 I ; ILL TO PROPERTY LINE. M ` + BW 23.00 zc_�c xx��c x�c x-x��- -�c-�c�c_ x�c-�c_mac_ -�c=�c-�- ��c, + 11.08.22 UPDATE PROPOSED RESIDENCE S 57°42'00"W ' ' 175.00" v ° FFE AS PER ARCHITECT. PROPOSED PROPOSED PROPOSED MESH+ PROPOSED WIRE MESH POOL RETAINING WALL, WOOD POOL FENCE+ RETAINING WALL, FENCE TYP. GATES TYP. I I s e a I 1rTMM 0 P R M I I NOT FOR CONSTRUCTION I TITLE: � I sou I SITE RIV c PLAN Rps S RO LEGEND qD _ PROPERTY LINE (5) - EXISTING CONTOUR 0 5 10 PROPOSED CONTOUR x(75.0) EXISTING ELEVATION +25.18 PROPOSED ELEVATION SCALE 1" = 10' TW TOP OF WALL DRAWN BY: BW BOTTOM OF WALL C.EAST CHECKED BY: L 1 TS TOP OF STAIR S.PAETZEL BS BOTTOM OF STAIR DATE:2022.07.14 REVISED:2022.09.06 SHEET OF 1 2022.11.08 EXISTING SEPTIC EXISTING S.C. T.M. N0. DISTRICT: 1000 SECTION: 110 BLOCK: 3 LOT(S): 26 TO BE ABANDONED 1 112 STY AND BACKnLLED FRM. DWELLING WITH CLEAN COARSE SAND. 3 BEDROOM FFL 28.0 #4980 DWELLINGS ix FRM. ' " GARAGE TO BE DEMOLISHED W/PUBLIC WATER N 5 '7 4 2 0 O E CELLAR ENT. 150' STONE DRIVEWAY MON. 4 CHAINLINK FENqE 0. 6'N 6 ' L CKADE CONC. BLK. WALL 17 5 . 0 0 ' I 0.8 'S 00 I � � YL N �� � E 4. 5 � G.M. � � � o I � o N L 2 ° - SHED - - - - - - - 50.2 , '-� i r - �' TO BE RE OVED - 1 EL 2 4. 1 15"OAK o o co 8. 1 -p 112.3 I > or�� 18 OAK -� I z Lai 311 .0 r N .o 5. 5 p �, cA PROPOSED r MON. �g 00 O m L U - %';%:�%:�'%; -2 STY N z 1 o ,'�--;�;;-;; -FRM. DWELLING-�'%%��"��' PROPOSED � c� - -FFL 28.0 :2 ► COVERED PORCH 1 FF1 _ x v' 79. 9 25.5 1 1 .4 c� c� � DECK �N � -0- - - - —I 18 OAK 84. 9 ' L 26.81 1 . 7 �;7• - - - WATER SER CE z W.M. 1 J ► ; ; 1� ';' TO REMAI I Q PROPOSED I w COVERED PORCH ► - 4.0 '-; 1 STY. %1'' ''' _ _ » FTI I . �` _ 20 OAK ► EXISTING n Q m i •� �; ;.�,,, ASPHALT _ v o 1 WALK & RIVEWALn ? v o z _ G�%;' %:� ''; ''; _WINDOW _ TO BE RE OVED 1 Co EL 2 6. 3 %-;'-� -- J- r WELL - - - - - _ _ _ _ - 1 o m U �--_ wm O � D TIMBER wALLs PROPOSED i - _ 1 0 0- PERGOLA '' '' ''' ''' ''' ''' R DECK %27. 7' - - i 0.5 'W WOOD _- � _ ' -_- °-� - v' EPS -� SCREENED-- O OVE HE DA W/ 6' to e r ed _ PORCH_ '�,, O 1 TQ BE WIRES - _2 7. 7' = °) O I W/U G. REPLACE p � _ - _- � I p WIRES �p COVE FED 37•2 ' PORCH 1 " <9 O \ v v V S 5 '70 4 2 ' 0 0 "W 1 '7 5 . 0 0 ' DWELLINGS W/PUBLIC WATER ELEV. 24.4 150' OL DR BROWN 0.8 THE WATER '31 Y, WELLS, DRYWELLS AND CESSPOOL REVISED 12 — 2 0 — 21 0 SANDY LOAM LOCATIONS SHOWN ARE FROM FIELD OBSERVATIONS AND OR DATA OBTAINED FROM OTHERS. REVISED 10 — 01 - 19 � BROWN REVISED 09 - 10 - 19 NAVD88 o LOAMY SAND r AREA: 17, 500 S. F. O R 0. 4 0 ACRES ELEVA TION DA TUM: _ _______________ SM 3.8 ' UNAUTHORIZED AL TERA TION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. SO SW THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE U THE IMPROVEMENTS. EASEMENTS MEDIUM NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, ADDITIONAL STRUCTURES OR AND OTHER IMP 0 VEMEN S E SEMEN S 1 S ORES RECORDED OR UNRECORDED ARE NOT GUARA N TEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY TYPICAL CLEAN 0 U T TO AND/OR SUBSURFACE C TRU E� SLATE OR COARSE 12.4 ' SURVEY OF: DE- SCRIBED PROPERTY CERTIFIED TO: MARK LOCKWOOD; SUITABLE COVE STOPPER END SAND 0 F NE�,� OR PLUG 04 W/GRAVEL MAP OF: N M 0 ROBIN LOCKWOOD • wow � FILED: �� cy FIDELITY NATIONAL TITLE INSURANCE SERVICES, LLC, SITUATED AT: CUTCHOGUE r Y o JP MORGAN CHASE BANK, N.A. ; 30° ELBOW TOWN OF: SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC 60° WYE NO WATER SUFFOLK COUNTY, NEW YORK �s 050882 �� Professional Land Surveying and Design 17' P.O. Box 153 Aquebogue, New York 11931 FLOW-Im - JULY 20, 2019 FILE -7# SCALE: 1 11-201 DATE:JAN. 19 2017 PHONE (631)298-1588 FAX (631) 298-1588 K. WOYCHUK LS 1 / — 0 8 N. Y.S. LISC. NO. 050882 maintaining the records of Robert J. Hennessy & Kenneth M. Woychuk l i APP 0 ED AS NOTED DATE• B.P.# FEE BY. NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS:' 1. FOUNDATION-TWO REOUIR177 FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE& TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTHOLD TOWN A SOUTHOLD TO PLANNING BOARD SOUTHOLD WN TRUSTEES - - -__N,Y,S.DE SO LD HPC SCH 1 , OCCUPANCY OR USE"IS UNLAWFUL WITHOUT CE-RTIFICATi DF OCCUPANCY ELECTRICAL INSPECTION REQUIRED o l t .. GENERAC° - GUARDIAN° SERIES ®�22/�4 k� Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power" Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz G007209-0,G007210-0(Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution"controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor ;.. " ® ti • Standard Wi-Fi®connectivity • System status&maintenance interval LED indicators '...... �s • Sound attenuated enclosure ��+1 • Flexible fuel line connector • Natural gas or LP gas operation GENERAC • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure. 'Must be located away from doors,windows,and fresh air intakes and in accordance with local codes, cONus or C �L UsQUry https.•//assets.swri.org/library/Directory0/ListedProducts/ `XET "'°°'re� Constructionlndustry/973_DoC_204_13204-01-01_Re6pol LISTED Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN& RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1 O TRUE POWER""ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK°CONNECTIVITY:FREE with select Guardian Series Home standby O PWRVIEW"" TRANSFER SWITCH: The Generac PWRview Automatic Transfer generators, Mobile Link Wi-Fi allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smartphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power.The PWRview energy monitor is a simple to use and Mobile Link,users are taken care of before the next power outage. low cost tool which helps save money over the life of the generator.Included with model G007210-0. GENERAC' w GENERAC PROMISEo�.f �' PWR f GENERAC® 20/22/24 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased.fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,lightweight unit that operates 25%more efficientlythan a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. PWRview Transfer Switch (if applicable) • PWRview energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution- Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. � k GENERAC® 20/22/24 kW Features and Benefits Unit _ • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. Installation System ' • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(WI-Fi equipped models only) • Ability to view generator status Monitor generator with a-smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. i i GENERAC® 20/22/24 kW - Specifications Generator Model G007038-1 G007042-2 G007038-3 GO07042-3 G007209-0 G007039-1 G007043-2 G007039-3 GO07043-3 G00721O-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 I(W) _ .., _....�_. ._.-._. - �Rated ma imum con inuous borer act ' 'i ____ _ _,p �CapLL iy(LP);�,_.__.:.�•,_• --, ,Y, _,�_ _ M .-;'20,000.Wati's"'�, `��22;DOQWatts':�w :20;0O0�Watts'` —22,00OWatts"," "24;ODO.Wa'tts"'-' Rated maximum continuous power rapacity(NG) 18,000 Watts' 19,500 Watts` 18,000 Watts' 19,500 Watts* 21,000 Watts' Rated:voifa e''r-� :�, —r 24 �`r,' _"• L� 9 _ _ _ _ _ 0' Rated maximum continuous load current-�240 volts(LP/NG)_ 83.3/75.0 91.7/81.3 . 83.3/75.0 91.7/81.3 100/87.5 ' Total Harmonic'Distortiin, 4 _ = Less th_ah 5 ___ x ,. .. ....� Main line circuit breaker 90 amp 4 100 amp_ 90 amp 100 amp 100 amp Phases: -,,.�._..�.„•,;--.�• r-,-a- - ,1-'_ _„--,.,^.._,_,�:w7 ,a:..:..:: .' .....................,,._.,._.__.._ .6; __,____^<,..,._.,... ...__,,..__,......< :._-.._..__......,._. ,_. ....,.._-. .....-_.._,.,...«.,L.,..........,.,� .,._....t,•. .»._. t...,,.:car:..,....._...—,..,......a.�.,...,.....,.i:a Number of rotor poles 2 Ratetl AGfre uenc T"", - �,,,- q Y fit,`: ;k :6U:z' Power factor 1.0 iBatte re uireinenn not Included :' "r= "'i ""- "'' - _ _ z, ry q _( } _�12 Vlis;-6roup 26R 540 CCA minimum o�Gioup 35A�M 650 CCA,minimum' Unit weight(lb/kg) 448/203 466/2111 w 436/198� ~445%202 455/206 :48 z 25 z 29 121.9 z 63'.5 ! _ Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load" �67� 67 67 - 67 67 iSound,outpuf ind6(A}at 23.it(7 rnj]witti geneiztonui Quiet=Test':Iow'speetl:exercise mode`*, 55= 57 `m ':5F ;57` a 'S7 t ,___w...us-._.,m.....w-,..»:.......x,._._..,...F....._.................._-.cw.u�..,.....s.".,. ..u.-.,..c_.........,..w.. .a....+.,_.._x.._.,,.,,r.....w.e.r_.._..aa».. ..........d.u..kw._...--.._,_..,....,,..,,.,.._,._..,...,.�,._.,..e-.,.. Exercise duration -5 min Engine Engine type GENERAC G-Force 1000 Series .cY _ Displacement 999 cc �yC linderblo'ck':7,_ _ _. ..._......,,,.._u;�._...,_»_�_....� -_._....,r,.:,::vt_w._.._.-._,..�..�__...,..,_.,.;'�.Y:e��..�::^.,.:::��:,�Aluminumw/•cast ironsleeve�'�,;,, .':'�-. , ' . Valve arrangement Overhead valve I r iiion� g_ sy, $61id=state:w/ma nefo.',' ;,T ; Governor system __.. - _a_ .._ �. ._....__•.�..._...,-_ ._.u-_._..�Electronic__, Com ressioniatio :=r`_ _ Starter _._..__..��,.. 12VDCM Oil ra ci includin filter_ _ - _.� v,,,. : �...�7_. P?_h 9. ?PProz:1.91.%1:8L;:` Operating rpm 3,600 - jFuel,consumption g-.Natural r x- ,r-:'. :, 04`5,Z8 + 28'6°4 1!2 Lgad._., ... .:.w'•,..:,.'. . } `>.,` ,s 2. 'd.,. .) 2_ ( 6) Y.'~f ";"164,(4.64j Ful6 Loatl :_ 301;(8:52). 327'(9 26) 287(8.13), ' 306(8.66), `y Li uitl ro carrel. 'ft3/hr al/hr 87-2:37 8.99.' 92�•53'9'S7 " 8{-1/2"Lead ( )[ l-' (2. )[,. ,) 6.(2:36)'[$.95]:', '92(2,53);[9`.57]�. `-Full Loatl r" _ __ 130(3.56)[13:48]' 142(3:90)':[1.4.77).•:;136(3:74)'[14.15] _ 142'(3,90j[14.77] j Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for<LP gas.For BTU content,multiply ft3/hr x 2500(LP)or Offir x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26 ING). Controls Two-line plain text multilingual LCD_ Simple user interface for ease of operation. M@de Eons:-AUTO. "" _ __ _ _' _ _ _ _ " -ir__ °,:u ,Automatic start on ut)li`"failure:Weekl,:B%weekl,or.MonthI seselectable exeraser: MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. Ready to Run/Maintenance messages Standard_ `En ine-�unhouri4 dication'�" r>"` _ "?' :f` -_-- - - _ 9 __ _ `Standard.; , Programmable start delay between 2-1500 seconds W Standard(programmable by dealer only) t"UTiIF Volt E L'oss Return F_CLAI atl'ustable tirownbut'settin t h_ 9___!. _y 1 r( „ ,9)_': From°.140=1.21'V7fi90 216,U Future Set Capable Exerciser/Exercise Set Error warning v Standard _,__ �- T_ ,_.-s _ 7. . ..- . .- - Run/Alarm/Maintenancelbgs ��` �'"-��^�-�"''' - _`�""''�"';50•ev_ents,eac'h"'�_`�___ Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter'lock'--out µ ,, "Siarte�cannot re-engage until 5 sec aflerengine.has'sto Smart Battery Charger Standard )ChargerFault/Missing"AC warning_ _" "�';.; - Standard '�' 77 Low Battery/Battery Problem Protection and Battery Condition indication Standard ,Automatic Voltage'Regiilation with Ovec and,Under_Voltage Protection ""' - " '' rd: '' - .,_....._x....—.v...._,-x�...a.�.•....-a,..,--.....+...�_u..,.._..-t,...:'.'s.l�...n_....v,.._,,..,.t..i"..w.....-�. =Standa Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safely Feu_s d/F'use'Porbelm_' _ : =_StandardFrotectionu : _ Automatic Low Oil Pressure/High Oil Temperature Shutdown -Standard OvePcranWOveis eed^.72'Hz r m:Sense Loss,Shutdown """ " " _ - �" 'Standard'- ..,.� High Engine Temperature Shutdown Standard 'I'Intemal FaulUlncorrect W)rinroteciiod '~ :b?4 "` Standard' - - t 9 - 4.-. Common external fault capability _ _ Standard Field upgredab_ ffrmw_are: i L s _ Standard.. "Sound levels are taken from the front of the generator.Sound levels taken from othersides ofthe generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(Ail ratings in accordance with BS5514,ISO3046 and DIN6271).'Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1.000 ft(304.8 m)above sea level;and also will decrease approximately 1%for each 10°F(6°C)above 60°F(16°C). GENERAC® 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007039-1,G007039-3(20 kW) G007043-2,G007043-3(22 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. - - - -� - - — ---- —t �No:of poles- _ _ 2 _� • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Current rating(amps) _ 200 with Smart Management Modules(SMMs). rVolfa a rating(VAC ' '120%240,10' - • Elecbically upeialed,mechanically-lield contacts for fast,clean connections. Utility voltage monitor(fixed)" • Rated for all classes of load,100%equipment rated,both inductive and resistive. -Pick-up 80% -Dropout 65% • 2-pole,250 VAC contactors. tR` eturn_to Utility'• ��— .Approx.is sec 7_ M j • Service equipment rated,dual coil design. Exercises bi-weekly for 5 minutes* _ _Standard • Rated for both aluminum and copper conductors. [E-rl-:,Lrr-U-L-'lIi-steedd Stan . st r dard. . .T^—Z Enclosure type � � NEMANL 311 • Main contacts are silver plated or silver alloy to resist welding and sticking. Circwt breaker protected 22,000, : • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly W, 200 Amps 120/240,1a Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 1 H2 HI Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM DEPTH �W2 PWRview Automatic Transfer Switch Features Model G007210-0(24 kW) • Integrated PWRview monitor provides real-time energy usage data through PWRview app. eNO.Of poles .- ___ 2 Current rating(amps) 200 • Intelligently manages up to four air conditioner loads with no additional hardware. Voltage rating(VAC) _ Vu J i2o%240_;_1.0 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Utility voltage monitor(fixed)* with Smart Management Modules(SMMs). -Pick-up 80% -Dropout 65% • Electrically operated,mechanically-held contacts for fast,clean connections. eturr -_n to Uiiii '' ,~ ' ,Approz:l3•sec. _i • Rated for all classes of load,100%equipment rated,both inductive and resistive. Exercises bi-weekly for 5 minutes* Standard • 2-pole,250 VAC contactors. E or UL Iistetl_' __ �� �� "Standard • . - V • Service equipment rated,dual coil design. Enclosure type NEMA 3R RCircuit breaker protected '22;000 �^ -- • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller Exercise can be set to weekly,bi-weekly,or monthly • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Heavy duty Generac Contactor is an ETL recognized device. w, Dimensions 200 Amps 120/240,1e Open Transition Service Rated Height Width H2 HI H1 H2 W1 W2 Depth in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges „ Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM:-#6 2/0-#14 GENERAC® 20/22/24 kW Available Accessories Model#.. Pr_ado_ct•' t ' " ;t Descri`tinri .'•mow �, _ GI 005819 0 — ,26R Well Battery�� ��Every standby generator�requires a battery to start the system.Generac�offers the recommended 26R wet cell battery for I i ruse with all air-cooled standby product(excluding PowerPacto). IG007101-0 jBattery Pad Warmer JPad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF 18°C Not nec- tessary for use with AGM-style batteries). ; 67_102_0— 10il Warmer — � 'Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0 IF fG007103-1 JBreather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where j }heavy icing occurs. �G005621-0 }Auxiliary Transfer Switch—lThe auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be 1 4Contact Kit !needed.Not compatible with 50 amp pre-wired switches. IG007027-0-Bisque IFascia Base Wrap Kit T e fascea base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured !(Standard on 22/24 kW) lappearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. W05703-0-Bisque Touch-Up Paint Kit ;If thetgenerator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion.; IThe touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. tG006485 0 !Scheduled Maintenance Kit iGenerac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a lGenerac automatic standby generator(oil not included). } ..__. _..,...-__.. __.____-. _-.___ _---_.._...- ____.__._.— ____m ___ _ ___ :G007005-0 Wi-Fi LP Tank Fuel Level IThe Wi-FI enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the ;Monitor )LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta-f i ftus alerts are available through a free application to notify users when the LP tank is.in need of a refill. _ _ i }G007000 0(50 amp);Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.Itmanages large eleci IG007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce- e(100 amp) the overall size and cost of the system. .,_-- G007169 0-4G LTE iMobile Linker Cellular iThe Mobile Link family of Cellular Accessories allow to monitor generator status from anywhere in the world,using j IG007170-0-Wi-Fi/ !Accessories is smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us-1 (Ethernet {ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,+ users are taken care of before the next power outage. `G007220-0-Bisque—`Base Plug Kit_ •__._ _ Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit; P contains four plugs,sufficient for use on a single air-cooled home standby generator. i _Dimensions &.UPCs Model UPC 637.E mm 1218 mm [25.1 In] [48.0 In] G007038-1 696471074185 G007038-3 696471074185 O G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727.2 mm [28.fi In] G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 0 o 0 G007209-0 696471071511 G007210-0 696471078220 648 mm 1232 mm 125.5 in] [48.5 in] LEFT SIDE VIEW FRONT VIEW r Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENERAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • genera c.com ©2020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Part No.A0000937814 Rev.B 07/30/2020