Loading...
HomeMy WebLinkAbout50962-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES IUNTOILNE SET OF FULL COMPLETON OAPPROVED PLANS AND SPECIFICATIONS F THE WORK AUTHORIZED) Perr'nit #: 50962 Date: 7/17/2024 Permission is hereby granted to: T as Matthew 505 Mt Beulah Ave Southold NY 11971 To: Install generator as applied for. At premises located at: 505 Mt Beulah Ave Southold SCTM #473889 Sec/Block/Lot# 51.-2-8.5 Pursuant to application dated 6/29/2024 and approved by the BuildingIns To expire on 1/1612026. Inspector. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total $325.00 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 haps.-Hwww.,;outho1d1ownu .go Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only E C E E M PERMIT NO, 1-�»' Building Inspector �MA,Y 2 9 2024 U Applications and forms must be'filled out in their entirety. Incomplete 7 applications will not be accepted, Where the Applicant is not the owner,an Building Department Owner's Authorization form(Page 2)shall be completed. Town of Southold Date:May 28, 2024 OWNER(S)OF PROPERTY'. Name:Matthew Tyas E�M::#:10:00-051-2-8.005 Project Address:505 Mt Beaulah Avenue Southold NY 11971 Phone#:917-854-9501 Email: Mailing Address:505 Mt Beaulah Avenue Southold NY 11971 CONTACT PERSON: Name:Kristina Phillips ALL WRIGHT ELECTRIC Mailing Address:1290 Flanders Rd Flanders, NY 11901 Phone#:631-353-3911 Email:kristina@allwrightelectric.com DESIGN;PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: I CONTRACTOR INFORMATION: Name:All Wright Electric Mailing Address:1290 Flanders Rd Flanders NY 11901 Phone#:631-353-3911 Email:kristina@allwrightelectric.corn DESCRIPTION OF PROPOSED CONgTRUCION,11 ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: DOther26KW Horne Standby Generator $13,113 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes CNo 1 PROPERTY INFORMATION< Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ❑No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional Is responsible for all dralnage andstorm water Issues as provided by Chapter,236 of the Town Code; APPLICATION IS HEREBY MADE to the Building;DePartment for the issuance-of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York-and other applicable Laws,-Ordinances or Regulations;'for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply witiiall-applicable lawn ordinances,building code, housing code and regulations and to admit authorized inspectors on,premisesand-in bullding(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section x0.45 of the New York State Penal Law. Application Submitted By(print and ht igAuthorized Agent []OwnerSignature of Applicant: Date: 5/28/2024 STATE OF NEW YORK) SS: COUNTY OF Suffolk Richard Wright being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is theContractor Electrician (Contractor, Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 28 day of May 24 _.,,_.. 20 Not KRISTINA A.PH91HS NOTARY PUBLIC,STATE OF NEW YORK Registration No.01PH5046053 PROPERTY OWNER AUTHORIZATION QuWifnd mi Suffolk (Where the applicant is not the owner) Cai�mtssipttla:ptrrs icily `� Matthew Tyas residing at 505 Mt. Beaulah Ave g Southold All Wright Electric do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. & Oc,0_1151� 5/20/24 Owner's Signature Date Matthew Tyas Print Owner's Name 2 �o Building De. artnigit Application AUTHORIZATION (Where the Applicant is not the Owner) I M�aT residing at � -. (Print property owner's name) (Mailing Address) se, 4,.4h p (� _ do hereby authorize t4 L c woftc H7- (Agent) to apply on my behalf to the Southold Building Department. S /-6012ct (Owner's Signature) (Date) (Print Owner's Name) BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 x Southold, New York 1 1 971-0959 SS 01 Telephone (631) 765-1802 - FAX (631) 765-9502 "amesh southoldtownn . ov seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5/28/2024 Company Name: ALL WRIGHT ELECTRIC Electrician's Name: Richard Wright License No.: 43457-ME Elec. email: kristina@allwrightelectric.com Elec. Phone No: 631-353-3911 ❑I request an email copy of Certificate of Compliance Elec. Address.: 1290 Flanders Rd Flanders NY 11901 JOB SITE INFORMATION (All Information Required) Name: Matthew Tyas Address: 505 Mt Beaulah Ave Southold NY 11971 Cross Street: Phone No.: 917-854-9501 Bldg.Permit#: 5ogofemail:matthewjtyas@gmail.com Tax Map District: 1000 Section:51 Block: 2 Lot:8.005 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of 26KW Home Standby Generator Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES NO 7 Rough In ❑, Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# ❑New Service[]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals U 1 H Frame Pole Work done on Service? Y MN Additional Information:. PAYMENT DUE WITH APPLICATION MAPt]P PRCMT4 LOT 2 As BROWN ON t FMAL FLAT-CLUSTER CONSERVATION SUDOMS10N A� 1 PQR EDWARD C.BOOTH AND PATMA S.ROOM PAFLnhY 4 2005 W THEsurFaAc cu»rTv CM6sotmLCE AS tarrrRI.1 1xxc TOWN Of WWII" ur� 9UPFOs]i OOiP�Y,i�1YYURfG AREA=63—Mok S.F.or t3W ACRES H 1 r PWW �9+Y t M k p r v i 0 d1 �m ti �rG F r � w pr� 'y m,c ti ct l�a 111 ., cl •, w'w+rvwm'rapwlWM`>ti9R p4Va+VHbmMH+'x'YWtvA WlwumW'+ap+"4 MIY+wMMW'RY'lAtl.waUW�wMI<dW'Igri.WN1Rm1F�l�f.MdONR!-fhBy 14dYAro NWuvU rWhS.',iYllk '' �� &1 i LC"�CII.l�1tYiS1YItZlH RS�UII�AH1 3 �1 mumewrvmuwr.,ewroiw&xnuw w.mw cewMrcAw�mear M^uuyu ew e, � uerwr�af�ou ae ueowu.svn�..�o.ew,n� y1 ! �.maxr,ewwu�.r n r�e+a>xw+r >dm r wwwwm � �r>�ew�w�ra ,+wwnx>d an lwrarw•�^nwi.*✓ 'wwnw„wm�nv�am o re�w wx, mreo- wa a,*�uam ¢m r�'nrr�+m��rrv�uww�au""�umo- aw",��,•r wd xua xima nr+vrro+wo-rwrvv m aurmr -,�,wamro �,. '� axm m1+mr�ux oaarm sae�wW eanro-xw n w �wm� 'x@:w mmyyrm,�w ^A'mnriW'+nNxwwbrn7"' mwi + H^&MmRraiw. r+wawn,wwwuspmw�rr «ra- ( - �r9fi wr+r.wgwnw.a�W&�mnY rU�p rv+mv ti4i7H F'i�r4M. 1 17M, �i —i— w G. J�x.I�i1L � „«.mro ! w mm.mw rnmw,,�prmai•rs� y e WC, ..,.mrau +wwr.w; Y�al�rerx, r� L'Kr Aa buat STIr"T vxmm „r~awe*�wara;m.^^,warix brwsmr•��. ,. µGRATHK 5.0.1�..,, 1 avo-7.f.ti^4r � ��.A'9"GSr'ir�mw�n tl M kbP N ) uu wA M tl�{ -f M!VMWUV vo,.�yYY.� ��qM �kJ!1. f "•-„in Hasp .o. I xu ERYro KY� 1 AnlC,"`C>R0 CERTIFICATE OF LIABILITY INSURANCE DATEIDDIYYYV) 057012024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In Ileu of such endorsement(s). PRODUCER CACT ANT John MicenSPHONE JOHN MICENA � I 631-288-4454ma�wi 631-288 8039 E-MAIL .... Micena n enrrl NatlDRal. r PO BOX 777 R A:�pFAR INSURERS)AFFORDING COVERAGE , t-MAIL .,..w�...IN . .._.—. ., .. TY INSURANCE CO EAST QUOGUE _ NY 11942 IHSURE M FAMILY CASUAL INSURED INSURANCE CO 1 IHSURE�Rp. UNITED FARM FAMILY .. ,..I ALL WRIGHT 1290 FLANDERS RD t ELECTRIC CORP �asUi�Rc; _a. m R.a . �-_u. _,.. ----- INSURERE.,,_................ .......,.........,.. .. ,�m...,,.� ..........�.. ................... RIVERHEAD NY 11901 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, iLTR aib154�"OeR�.,... n, POLiCYNUNVB.. m .APO y��_ _ q. TYPEOFINSURANCE yyyY ryyyy LIMITS A COMMERCIAL GENERAL LIABILITY ^3102XO750 2/23124 2/23/25 EACH OCCURRENCE $ 1000,000 m ` �O t�s 6kT�f1 CLAIMS-MADE ��OCCUR ss�WC% 100,000.- ,, X CONTRACTUAL LIABILITY $ 5000 ,r. ED EXP dAlroy o prrr;�an, _RSONA'L&ADV INJURY $ 1,000,000 GEN'L AG ... ,..I .-..... _^GENERAL AGT REGATE.. ..0... AGGREGATE LIMIT APPLIES PER: '�' - $ 2 000,000 POLICY h PRO LOC  �ROOUCTS-COMPfOP AGG $ 2,000,000 OTHER:!. B AUTOMOBILE LIABILITY 310105208 2/23124 2/23/25 GONBUeDSBNGLCUhlIE $ 1,000,000 �74+RL. .. _ '..ANY AUTO BODILY INJURY(Per person) $ mm...u�.�. w OWNED SCHEDULED ... � AUTOS ONLY +"` AUTOS 30DILY INJURY(Per aeoldent) $ HIRED NON-OWNED I �aiaPm R� E- .„DAMAG $ AUTOS ONLY ___..._ AUTOS ONLY A X UMBRELLA LIAe occuR 3101 E3606 2/23/24 2/23125 _ ... f AGH OCCURRENCE $ 1 000,000 ...�. TENTON CLAIMS-MADE...d......_.. .m._._._..............................-... ..._�.....-.. - .. �.......... AGGREGATE_ .. PER 'DfiH��.. $ .W. DEDCO DENS _ 0,000 EXCESB LIA RE $ S:L�T,U�,�. �R ,T 1,00,,,,,,, AND EMPLOYERS LIABILITY E._i,EACH A ... WORKERS COMPENSATION OFFpCE6'k1EIW)pERP1VTTNE°NkE:XECIJTpVE YIN N l A ( . ..DISEASE ---—P .. $ ANYprgKO roRleT�)Pv E$CLODETJ -. EA QH rnddesc In FNHI E POLICY LIMIT 1 $ EE UI vas, IPTI N aroW a �LLL DISEAS..,m..p . OL.+�:RIFro'T'IR'SN CriP^�1'EPEA'1101hdai a:evroV'mtivw $ 1 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANYOF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 ROUTE 25 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN SOUTHOLD, NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE I ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD 4� Now York State Insurance Fund PO Box 66699,Albany,NY 12206 I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 472951153 LOVELL SAFETY MGMT CO., LLC 22 CORTLANDT STREET 33RD FLR NEW YORK NY 10007 1 is]N SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ALL WRIGHT ELECTRIC CORP. TOWN OF SOUTHOLD 1290 FLANDERS ROAD 54375 ROUTE 25 FLANDERS NY 11901 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z2466 060-7 800368 04/01/2024 TO 04/0112025 5/20/2024 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2466 060-7, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS'IIWWW.NYSIF.COMICERT10ERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION, PRESIDENT RICHARD WRIGHT 1 OF 1 OF ALL WRIGHT ELECTRIC CORP. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY, NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 1053308286 U-26.3 56 q� GENERAC' 26 kW GUARDIAN® SERIES Residential Standby Generators Air-Cooled Gas Engine Standby Power Rating INCLUDES: 21.-C-0,GO1729'1- (Alun'Einun'r-131sq:re)-2F-W,/c`HZ • True Power"Electrical Technology • Two-line multilingual digital LCD Evolution'"controller (Engl ish7Spanis!VFrench/Portuguese) • 200 amp service rated transfer switch available ! Electronic governor • Standard WI-F 'connectivity ^,. • System status&maintenanceinterval LED indicators «='�;.', - .g=; .^: e ' r . Sound attenuated enclosure Flexible fuel line connector . =` " 0 Natural gas or LP gas operation <: : • 5 Year l imited warranty • Base fascia ...... • Listed and labeled for installation as close as 18 in(457 mm)to a ,r. �`• ' structure.' *Must be located away from doors,windows,and fresh air intakes and in ON esor C UL U5 U accordance with local codes. c USTEO � 0 Nate:CETL or CUL certification only applies to unbundled wits and units packaged with limited circuit switches.Um�packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the hearl of Gen- 0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible.Generac,'s•G- state-of--the-art power maximizing regulation system is standard an all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized EAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are.purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures add extreme operating conditions. loads to the engine.Digital voltage regulation at %. 0 TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave 0 SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This - provides parts and service know-how for the entire un't,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. G TEST CRITERIA: 0 GENERAL TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1.22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY- product line is offered with its own transfer systems and controls for total system compatibility. C MOBILE UNK*'CONNECTIVITY:FREE with select Guardian Series Home standby generators,Mobile Link Wi-Fi allows users to monitor generator status from any- where in die world using a smadphone,tablet,or PC.Easily access information such as the current operating,status and maintenance alerts.,Users can connect an account to an authorized service dealer for fast,V•endly,and proactive service.With Mobile Link,users are taken care of before the next power outage. - wIPROMISE a� @@ ��" t 2 GENERAL' 26 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a ycar/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allowstor a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed Inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evoltdion"'Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible legs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. ♦ Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator vultage sensing Constantly monitors,generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups o1 the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-tip Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,selpointapproximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hirged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied texlured epoxy paint for added durability. • Enclosed critical grade muffler Wei,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. 1 GENER,A►C" 26 kW Features and Benefits Installation System * 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. 0 Integral sediment crap Meets IFGC and NFPA'54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphona,tablet,or computer at any time via the Mobile Link application for complete peace of mind. s Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information •Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. s Weather information Provides detailed local ambient weather conditions for generator location. V1 � GENERAC' , ^7 26 icW Specifications Generator Model G007290-0 GOOT291-0 (26 kW) t mm nn drpa4 Rated maximum continuous power capacity(NG) 22,500'We& W.:. ,_......,. ..,...... w __ Rated maximum continuous load current-240 volts(LP/NG) I OB.3/93.8 a,,.., � Mal.,line circuit breaker — _ 110 amp haler:.. ___M Number of rotor poles 2 ; ;.,, ...r W.60fft s Power factor - 1.0 13filhery:f()uTteme {tlflrrcfutled) ,.____ = .. __ 9 ;VaICfnu3?R,a7fG97rtfnifnu,nnrGf4�rr5fiGU&50;GGArnlnfnurr _ Jnit weight(lb;kg) 518/235 Dimensions.tzWxH'iry'1rn ' W=,WW 48aE229y:f1'9xu3�aa3r = Sound output to dB(A)at 23 ff(7 m)with generator operating at normal load'` 67 �aund af3lput In dB{A}at 23� }1f�w7flaratar to Quiet't"g3�,:_-ewL�q.exe cisa n:�cda; . : a7 ,'.;;.:�-:====;�2:°�,=�:� -=` Exereseduration _ 5min Engine Engine type GE.NERAC G-Force 1000 Series _=�= ` Dwplacemen; 999 cc t yhador bktch_- EMU Valve arrangement Overhead valve ------ Governor system Electronic _ Grom rind 0 • _- _��_ _.,.R_:.-.,, 01 Starter___ r 12VDC _...,..,;- -�:.::..- Operat'ng pm 3,600 f 2 Loa .�,_ �-�` _ •,.,fg',43i: _ Note:Fuel pipe.must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7In water column(0.87-1.74 kPa)for NG,10-12 In water column(2.49-2.99 kPa)fnr P gas. For BTU center:,multiply tta/hr x 2500(LP)or ttsAu x 1000 NG).For Megajoule content,multipP Whr x 93.15(LP)or W/nr x s726(MG). Controls Two-line plair;tez multilingual LCO Supple user interface[or ease of ope a0on. Nfo'8a-uttorssAflTO;:;-: °.==:-:� ;==�=-=W_ =�,-: `���W-r-��=�-•�.. ;.;.:: ::. ._-_:;_ .. AO�rmatrr~s riti:utffi �:talliitd.: ee 1 `lih'a�e �rlti :s�tsCa6t: _rciaer::,";: MANUAL Start with starter control,unit stays on.If utility fails,traas'er to load takes place. St4AS`Un){„PD+t(�f s +& 4111t?)Ii�ltfbh_L Of9tltop9 all( = Ready to Run/Maintenance messages Standard to rn ntrThourp'rh4€dagpr = - -- - w5ia�car6 _ �- - - a=- Programmable start delay between 2-1500 seconds Standard(programmable by dealer oily) 1 I MI` Voltage 61WRatt(in to lJhiityadju lab? (b[axwnout sctltr0} :. �: �w W,r w.Fry 349 ?i Y ka A0-2161f Future Set C41la xerciseOExercise Set Error warning Standard _V_._ Y_� `"° SRc�elitseach•.� cr'= r��:= -.__ Engine start sequence Cyclic cranking:16 sec on,7 rest(90 see maximum duration). Sfatlerlgck put : _ � erranrof rd errUa9Gnt�.6ec;affere utt-a5 bfapped W Smart Battery Charger Standard Low Battery/Battery Problem Protection and Battery CogdUon incication Standard �t-:rfotttatipil111f;z�oRcc�fationwith�+teta13i1ndrdVoltag�tM4lCeffan Inder-Frequency70verinadiStepper Overrurroat Proternirn; - _ Standard W�artM�W =�� Automatic Low Oil Pressure/high Oil Temperature Shutdown Standard C�"4%efr;�irt��fstaeed' 7��1t1r .�etisetu3"s'Shittdinttc:•:'�;� >,-`__��K:=:�;:,.::_...;..:= �=�.x: �:-_ _.�'=�Sl darQ Hgh Engine Temperature Shutdown Standard lntemaitaufl(fn anedl+htrfnL[prfltortusn - Comron external fault capability Staldard FialdupgradahTelftmTlars Rating de:`irilions-Optional Standby:Apolicable for supplying backup power for the duration of the utility power oafag:with correct maintenance pcdorrned. "No overload capability s available for this rating.(All ratirgs in accordance with aSW4.ISO3046,LIL2200,and DIN6271}.Maximum kilovolt amps and curronl arc scb,::et to and lim1rd by such factors as fuel BTUyMega;'oule content ambient temperature,altitude,engine power and condition:etc.Maximum power decreases approximately 3.5%for each 1,000 it(304.8 m)aoove sea level and approximately 1% for each 10°F(6°C)above 60°F(16'C).—Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installattgn parameters. U.S.EPA certified for ror omorgoncyapplications. GENERAC' :26 kW Switch Options Service Rated Automatic Transfer Switch Features -Madell Na of • Intelligently manages up to four air conditioner loads with no additional hardware. Current rating(arnps) 200 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction with Smart Management Modules(SMMs). Utility voltage monitor(fixed)* • Electrically operated,mechanical ly-held contacts for fast,clean connections. -pirk-41P 80% 46 Main breakers are rated for 80%continuous load. Dropout 65% 0 2-pole.250 VAC contactors. ETL or UL listed Standard M 40 Service equipment rated,dual coil design. dz,'W—W-7-1-0 • Rated for both aluminum and copper conductors. Circuit breawr protected 22,000 Age.. • Main contacts are silver plated or silver alloy to resist welding and sticking. �Fun Ion of Evolutioncondroller it NEMNUL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bl-weekly,or monthly Dimensions 200 Amps 120/240,lo qm Open Transition Service Rated Height Width HI H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 94.16 17.5 Wire Ranges Conductor L Neutral Lug "q Lug Ground Lug 250 MGM-#6 350MCM-#6 2/0-#14 --------62------ GENERAC' 26 kW Available Accessories Pctarlu�ii q��cct uaa. : a x µ I13007101-0 'Battery Pad Warmer 'Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0"F(-18°C).(Nott"nee- essary for use with AGM-style batteries). iG007102-0 ,Oil Warmer " {Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls oelow 0 IF(-18 nC). 1GO07103-1 ;Breather Warmer ,Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where I ;heavy icing occurs. I6005621-0Auxiliary Transfer Switch ;The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be x ;Contact Kit ;needed.Not compatible with 50 amp pre-wired switches. IG007027-0-Bisque [Fascia Base Wrap Kit :The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured l ;appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. I„ IG00570M-Bisque ;Touch-Up Paint Kit it the generator enclosures scratched or damaged,it is important to touch up the paint to protect fromfuture corrosion.a iThe touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. _...................,....0................ ....................;._,.............,.,,,,,,,.,.......,..,..,.,.,.,...,,.....,........,.,..,,,.:,.,...,...:.,...,....,.,,.,..,..............................,.....,.......,.,......,,,:.....,....,... IG006485-0 ;Scheduled Maintenance Kit;Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a, Generac automatic standby generator(oil net included). IG007009-0 ,LTE LP Tank Fuel Level iThe LTE enabled LP tarkfuel level monitor provides constant monitoring of the connected LPfuel tan<.Monitoring the LP Monitor Itanles fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Status 1 I Werts are available through a free application to notify users when the LP tank is in need of a refill. i I0007000-0(50 amp);smart lVGagement Module iSmart management Modules(5MM)are used to optimize the performance of a standby generator.It manages large elec- IG007006-0 [ itrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) ithe overall size and cost of the system. G007169-0-4G LTE Mobile Link Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator statuss from anywhere in the world,using G007170-0-Wi-FV Accessories `a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts Us- 'Ethernet iers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, fusers are taken care of before the next power outage. 1GO07220-0-Bisqu B Plug Kit 'Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured I ;appearance,as well as offers protectiorrfrom rodents and insects by covering the lifting holes located in the base.Kit> ?i ;contains four plugs,sufficient for use on a single air-cooled home standby generator. t IG007301-0 Y_~_ High Altitude Kit '.A high attitudeykit�may be required when operating over 2,000 It(610 m)above sea level per U.S.EPA regulations.Op-t ?erating the engine with the incorrect engine configuration at a given altitude may increase emissions and decrease fuel 3 ;efficiency and performance. Dimensions & PCs Model UPC 5,�•smm 12^e Mm f26.7 in) r48.0 in] G007290-0 696471087307 ------------------------ G007291-0 6964710V314 72'I.2 mm --- r29.6 4 j uaa mm ta.mm r25.51n] a8.6 im LEFT 510E VIEW FRONT VIEW DITensions showi ireappfoximale.See installation marwal for exact dilrensions.D0 NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RAC' Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189•generac.com MOMMONEM F52022 Gonorac Power Systems,Inc.All rights rosomd.All specirfcadons are subject to chango without notice.Part No.AOW2026694 Row.0 0 011 912 0 22