Loading...
HomeMy WebLinkAbout50270-Z �O�agUFFOL��oGy Town of Southold 5/14/2024 a P.O.Box 1179 o _ aff53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45182 Date: 5/14/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1700 Park Avenue,Mattituck SCTM#: 473889 Sec/Block/Lot: 123.-8-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/2/2024 pursuant to which Building Permit No. 50270 dated 1/29/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to an existing accessory building as applied for The certificate is issued to Kabakov,Emilia of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50270 04/17/2024 PLUMBERS CERTIFICATION DATED kV11- Afth(rAed Signatur o�SufFot,t�o TOWN OF SOUTHOLD aye BUILDING DEPARTMENT y TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit* 50270 Date: 1/29/2024 Permission is hereby granted to: Kabakov, Emilia 1700 Park Ave Mattituck, NY 11952 To: Install roof mounted solar panels to an accessory building as applied for per manufacturers specifications. Additional certification may be required. At premises located at: 1700 Park Avenue, Mattituck SCTM #473889 Sec/Block/Lot# 123.-8-5 Pursuant to application dated 1/2/2024 and approved by the Building Inspector. To expire on -7/30/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ACCESSORY BUILDING $100.00 Total: $325.00 Building Inspector OF SO!/j�,ol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q • �o sean.devlin(c-D-town.southold.ny.us Southold,NY 1 1 97 1-0959 'Q OOUNT`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Emilia Kabakov Address: 1700 Park Ave city:Mattituck st: NY zip: 11962 Building Permit#: 50270 Section: 123 Block: 8 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 4:86kW Roof Mounted PV Solar Energy System w/ (12)QcellQpeak DuoMLg10- 405W Modules, AC Combiner w/220(1) & 215(1) Breakers, on Backfed 22013reaker in Main Panel Notes: Solar on Long Shop Building Feeding the Long Shop Inspector Signature: Date: April 17, 2024 S.Devlin-Cent Electrical Compliance Form 50�-�� �o��OE SOUlyolo # # TOWN OF SOUTHOLD BUILDING DEPT. ourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL S040 - [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Pwovlile- jOcSI 1/7614�-l/ DATE INSPECTOR 4/17/24,4:59 PM IMG_5801 JPG { k, A „v 3 c� LI- ►.` APR 2 2 ?024 21 t f i https://mail.google.com/mail/u/0/#inbox?projector-1 l/l s r �` t � 4 } 1� OJ J� r Mom.. •+�..er�.�a..-.�...� ►�I it r i a 4 0 F F116 '�!■�! � _ I 4/17/24,4:59 IMG-5804JPG 10 4 1 r � R i https://mail.google.com/mail/u/O/#inbox?projector-- 4/l7/24,5:00 PM IMG_5805JPG I '7 v,-r ,A ■ a a �I t DISCONNECT POWER r BEFORE SERVICING Mftmwh-l/mail annals rnm/mail/u/O/Itinhnx)nmiector_I l�l ♦ Ito� for t � 4 WAN • _ f •• •11� 1 1 11 11 1 zono Sign Document|o:oxznuFFA-IoZJA-Tomn Town ofSouthold pr 1 OOl �p�� Building u� Department Town Hall Annex Building 54375 Route 25 kpQ 2 3 o094 p{}. Box117B ~ Southold, NYM871 . ~�-'` ^^ '� . � Subject: Roof Mounted Solar Panels at the Kabakov Residence, 1700 Park Ave, Mattituck. NY TU Town ofSouthold: I reviewed the solar energy system installation in the subject topic on April 10th, 2024. The units have been installed per the manufacturer's instructions and the construction drawings approved by the Building Oeportment, Town of Southold, New York. The solar panel installation is in compliance with the requirements of the 2020 Building Code of New York State, the 2017 National Electric Code, SEVASCE 07-16 "Minimum Design Loads for Buildings and Other Structures", NFPA Standard 70, and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. Markings in accordance with Section 690.53 of the National Electrical Code are provided. To the best ofnly belief and knowledge, the work in this doounnentia �oouroba. omnfornnetothe ' governing codes and standards applicable at the time of submission, and conforms with naoaonob|e standards of practice with the view to ea0aguond|n0 ||fe, heo|th, property, and public vve|fona. Sincerely, or- NEw Gennono Anthony Giuetra. PE. Great Eastern Services, Inc. PO Box 240 24 Harvey Rd LU Riverhead, NY 11801 yWobi|e: G31.235.O18B FIELD INSPECTION REPORT I DATE COMMENTS t n O FOUNDATION (1ST) J Q ------------------------------------ C FOUNDATION (2ND) z 0 ROUGH FRAMING& G t PLUMBING A 1 INSULATION PER N.Y. H STATE ENERGY CODE -� Ole- 4'it G.v. FINAL i r�w ADDITIONAL COMMENTS � 1 ( 32 °-° a P rt cv +CL rGc 141 1 -t I 2q E[ cc vtc eectcl C a� Li • 2312-q er� ,reed y A � Z AS n cam' J � d H O L z x x d b H i 7 �p�Su Q CGGz TOWN OF SOUTHO LdD -BUILdDING DEPARTMENT Town ball Annex 54375 Main Road F. ®. Box 1179 Southold NY 11971-0959 3p o a, Telephone (631) 765-1802 Fax (631) 765-9502 httl2s:,�!w,v"%,,.southoldtownn,,.Rov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only �' Q o s �n � �a PERMIT NO. Building Inspector: ' J AN ' 2 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an �z�9Fc�i��nepa ftt��-�'� Owner's Authorization form(Page 2)shall be completed. 5!i so riold Date: l I Va3 OWNER(S)OF PROPERTY: Dame: 6MIA 1`a,— Kabkkov TSCTM#l000- l a3. 08 , S, voo Project Address: '� O pky-k-,x) n � I I1GU.. 1�1 -k a f 4 11 g s Phone#: �3 l.. 2 - .7OLI I 1 �►�xG Ema il: Mailing Address: 1 "j D O �/� f �r U! I l n CONTACT PERSON-; ,_l 'V' 1 1 'l Name: Lo r-rA.l'n<_, D Mailing Address: -7410 SOl.AAd VY2 Phone#: (o 3 1 3 9 2 --7 0 q / Email: a 6 S , co1•✓► DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Z Email: CONTRACTOR INFORMATION: Name: d l�'D�i')� Y)f tA Mailing Address: 1 4 q 6 ;®"d O v MA4 ` 1 vcr 1,r,�l. Phone#: 3 v '-� D `r Email: Pe'y'e14S Q' DESCRIPTION OF PROPOSED C®NSTiRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair El Demolition Estimated Cost of Project: then I n,5 -a-0 ,So )a.vr P V 5 S$�-9a 1 �� 3 k� tv�,.� $ 8 9 � �a Will the lot be re-graded? Yes.XNo Will excess fill be removed from premises? ❑YesN32!NNo 3: - mo les 0 ce - a lG r>�Co 13 l< 1,a-- 1 !►v�l' E n 12 h 422 R to lu.S -^7a- -U l PROPERTY INFORMATION Existing use of property: P-cs, „_(.; /1 Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to t dq41`01 this property? ❑Yes 1KNo IF YES, PROVIDE A COPY. heck Box After heading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by apter 236 of the Town Code. APPLICATIO14 IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Gass A misdemeanor pursuant to Section 214.45 of the New York State Penal Law. Application Submitted By(print name): � ��-�-� I �� � i`pfrrkt--) Lothori2ed Agent ❑Owner Signature of Applicant: 11-0 W VL.La IA-L Date: P< ! );" STATE OF NEW YORK) cc SS: COUNTY OF SL4 f fo BC ) rr6LJ-rm� b I ��� being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, pp (S)he is the �®f)+I-O :.I t1Y--` (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ,,/ day of v-r e rer 20 2 LOUIS J ROMEO Lary Public Notary Public,State of New York No.01 R06314813 Qualified in Suffolk County PROPERTY OWNER AUTHORIZATION Commission Expires November 17,20.1d, (Where the applicant is not the owner) I, �DY)► � B ����aQC�sV residing at �-700 P&r)C do hereby authorize r-AMen4I✓Yt,cq LLC L.D(-fofw-, to apply on -b► my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Exiltl& r'-111nAb4K0V" Print Owner's Name iL 2 E o�g%3FFO�,��o BUILDING DEPARTMENT ReCMiC,.1FhInRheJtdV E TOWN OF SO t o = Town Hall Annex - 54375 M i oad - PO BoZ0�179 Southold, New Yor 1 971A59 4 Telephone (631) 765-1802 - FAX (631) 765-9502 1 roQe��sou$hold>$ot�nny.a�ov—seandc�s� b�c � in Gov gd'iwn 67 �Ysr� APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: ). J a Company Name: 61 eM cn4 Electrician's Name:DFsj rfeC., M � n n j eK License No.: �,� _ IN.4 t Elec. email: Pe r-rn i+5 Elec. Phone No: -)oico [91 request an email copy of Certificate of Compliance Elec. Address.: -7 4-7 o ,owq6. aVe-1 fA��4-,.tGK— ! JOB SITE INFORMATION (All Information Required) Name: E YYl►` 1 tk- a 1o�.kuv Address: 1-7oo P& -K. AVV fft _ wisp, Cross Street: I'�Gt r►� Q-�o u��a� �� Phone No.: (,0 6 1 ..5$$ . '7 0 L f' Bldg.Permit#: 50a 70 email: 9tYM i-A- Tax Map District: 1000 Section: la3 . Co Block: 0 S. OCR Lot: Ob 5 000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): ZYl ♦-1 l -F 1 lls 17 >roo o L w r P I Sy S (W v K--w Poe- a 11 -3 4.94 k� � � Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES FN7 NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES® NO Issued On Temp Information: (All information required) , Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter#, ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 D H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Yoe Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that came 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 1c.Federal Employer Identification Number of Insured Worts Location,of Insured(only requiredifcoverage is specificaliylimited to or Social Security Number certain locations in New York State,i.e.,Wrap-up Policy) 823336604 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) TOWN OF SOUTHOLD ShelterPoint Life htsurancs Company 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"W SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01/01/2023 to 12/31/2024 4. Policy provides the following benefits: ® A.Both disability and paid family leave benefits. HB.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employers employees eligh3le under the NYS Disability and Paid Family Leave Benefits Law. 0 B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By lud,ht (Signature of insurance tamer's authorized representative or NYS licensed Insurance Agent ofttwt insurance carnet) Telephone Number 516-829-8100 Name and Title Richard White, Chief Execulive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 6200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only If Box 48,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensatom Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee] Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to Issue this form. D8.120.1 (12-21) 11���Y��I�i���l�������lll��l'��I"II'lllf CERTIFICATE OF LIABILITY INSURANCE DnTE(M'7/lioorry 023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER 7HE COVERAGE AFFORDED BY THE POLICIES BELOW- THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: M the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement, A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemengs). PRODUCER ROBERT S.FEDE INSURANCE AGENCY NAME` PHONE - PAX 23 GREEN STREET,SUITE 102 No Eft . - E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS.F£DE INSURANCE Blsu AFFORDING COVERAGE NMI a INSURER A:ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURER Element Energy LLC B I DBA ELEMENT ENERGY SYSTEMS SURER 0. 7470 SOUND AVENUE 'IN"sue° MATTITUCK,NY 11952 OJSURERE. INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES_LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, TR TYPE OF INSURANCE e POLICY NUMBER 1 MIDO IlLICY Y MMMVrPOMY YY LIMITS IX COMMERCIAL GENERAL LIABILITY L1460036873 A X X 7/141Z023 7/14/2024 EACH OCCURRENCE $ 3,000,000 CLAIMS-MADE ©OCCUR Ur IUKU44�_u PREMISES JFa aocx a oe $ 100,000 IMA389203B MED EXP IAn,are Pemn) $ 5000 rIGENL Contractual LIa 7/1912022 7/1W024 PERSONAL dADV INJURY $ 3000000 GREGATE LIMIT APPLIES PER GENERAL AGGREGATE i 3,QQQ,Q00 CY a PROJECT L 1 LOCPRODUCTS-COMPlOPAGG $ER. s AVTOMOBiLELIABILITY CEOaR1Bl cclftt$WGLEIJMIT $ ANY AUTO BODILY INJURY(Per person) $ OWNED AUTOSSCHED LED BODILY INJURY(Par a=ident) $ AUTOS ONLY AUTOS HIRED NON-OWNFJ7 F'ROPERTV DAMAGE $AUTOS ONLY AUTOS ONLY PEgTnt $ UMBRELLA LIAS OCCUR EACH OCCURRENCE $ EXCESS LIAR HCLAIMS-MADE AGGREGATE $ QED IL I RETENnCN$ $ WORKERS COMPENSATION EW I2 4494445 PER ER AND EMPLOYERS'LIARLITV YIN 7A 3/2023 7/13/2024 STATUTE.ANY PROPRIETMPARTNEXECUTmE B OFFICERNMMBER EXCLUDED? NIA EL EACH ACCIDENT ; 1 QQ0 000 .describe under I yes ory In If yes, nd er EL DISEASE-EA EMPLOYE $ DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMB 3 NY State DBL r DSL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Addltlonal Remarks Schedule,may be attached H more spa"is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certlificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CIS 2037)(Blanket)on a non-contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town Of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS- AUTHCRV"REPRESENTATIVE R0bea'tS. Fede. ©1988-2015 ACORD CORPORATION. All rights reserved. Arnnn)t 11Jn44rnit NYSIF New York State Insurance Fund PO Box 66699,Albany,NY 12206 J nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) 0 � ^""AAA 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 VIA HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07/13/2023 TO 07/13/2024 711112023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDERS REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT NTTPS:/IWWW.NYSIF.COMICERTICERTVALASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS COMPENSATION ANDIOR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH QUIZ INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT SU NCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING BE VONS: MARRAT00KA POND ASATTINIX � I AVIATION DEEP HOLE CREEK I I + I I I � z 638.8' S 11R13'0"E Q Ey --° .. SELL if PROTECT O LOCATION z od I L I'1'++ S] OtDiII:G GREAT PKONIC BAY 1 z / 2 STY.FRAME BUILDING EXISTING]STORY BUMING I� �'.�_ em1r7�'NYc w� 0 1ff�� 5'I O j z °� G R E A T MAP LEGEND H y. L'' P,°usF II+'+���. P E C O N I C A J 5 �¢ B A Y Do zz N 11"13'0"Wcd 0 Id �'� SITE PLAN C I + SCALE: 1"=30'-0' MARRATOOKA ROAD 1 4 dz ` � A A SITE DATA: SEQUENCE OF PROJECT: SCTI V l OOO'�2 3'O�'OS3 1 SDEQFANNL;ttEARANCEOF MINLNUM SffE WDRX AS NEEDED.NfinLL BF4A55,MAVBAUf.fIt:FFNONGAf REOUi0.ED.RUNOFF DESCRIPTION: SQ.F A-I LOTCOVERACE' EXCAVATE: FILL: PROTECDONTO BE MHNTAINFD OURWGIFNGTH OF CONSiRUCTION.EXGVATON M1:Sf NOT BECA'1IN51LTHF tLICATIOVS OF UNOERG0.0W0VARFS.CABLES ANo PIPO HAVE 9FEN MAAK•D OR UYIR V-RIRGPON FROM EA.I [OMPANIE OR THE AREA IS CIFA0.CLEARTHE STc T LEAST]D 25 i'E'f OF APPUCABIE)i0.OMTHE PROIER PcRW4TE0.DO DO NOTCIEAR O0.IXGVATP PROPERTY: 102,91250,FT, -ACRE' LARGE AREAS TO FAR W ADVANCE OF CONSTRUCDON:DITUAR VEGETATION ONLY AS NEEDED,THN RESEED OR 4EPUNTT SOON AS l US :;'t �i7 A4FA5 APENCWGO0.D WE0.BEAR OTBE FACEBARRIERf RS QOHTEUCSTG BEGNSTRFES TOnMNEM RYTO AY5,1 UL llr\1 PROPDL:YWifutmf: 195B 56fT. NSTA.DW PEPAHNT HERE EHICDRNTER T NOTBEWSTAl1ID B3'00.5CONSTRUCENN BELWf.ATFMPOARV GRAYF DRIVf1UAYfRWDS BE V u WffAt`1D WSLFRf VD D:TE0.THEf04 SIZE U BUBISABIE PROPERTY. ...R"SO.FT 2.nACRE5 MEETS AND BOUNDS BY: ° ESTUM ACV 2 POLLUTIONCONTROL•CONSTRUCTIONDUMFSTERANDmRTALAVLOBEON nEANDMtLYTAINFDDURINGLENGTHOFPRDla. DIEN0. •.y�, D AR /OO Sp.FT. GROUND BANCE: 3 50 ROL•E%CAVATEDSgLTOBEREfPINED ON SITE ..Is-ON SRE PUN.0.TAIN AS MUCH TOP. POfABLFTO NATHAN TAFT CORWiN II PRESERVE3E0.VETHF ENVI0.0.NFNTP1 pDALI1Y OFTHE SUM DICA XCESS fA EUNs A HI DIEM SNtITHI NfMR00.AND FXCAVATO0. u- SHAM WSPECiPROPB0.NF00.E71'STINGVfMRfBEMLF ESOUFI .E D7MN/D CL IOASI 24K ON VfBAFRONITY T6E LAND SURVEYOR, LIC.• 50467 Fri a fl,..��,•.� -;.A- CONE BY HANG.WHEN TNETCPSOLLIf P0.FSFRVEO.TLLLTHF SOLL F10.fT,ANDTHEN REMOVE TOAfnfE LOGTION WDHAiRONT ..H" EXISTING NCUSF 38N SQ.R. 3.6% - EPID IOACDL.PROSECF GRMS,TREFS AND OILLF'A PLWSS WHENEVER PpSSIB'{ EXGVATMSHOIADBEMLEVELMMZBMS RVAIDNBENCH MA0.X PR:DRTOEXCAVATION.OVERdG �:. !•.^T.. - FCUN➢ATION HOIFSTO GNE PLENTY OF AOON iORAWELLDRAINWG BACXFIIIANDTO PROJIDF RDOM FO4ALL VAlUI SURVEYED: 12/14/2011 LIC+J '-t--+�•1" - FXIfWL PORCWDF[M R.6D750. -:: •. _ A).IFTHEDERNOFDC ATIONH6FEETORILDS,OVEAC411 3.OFFEf. EMSTING PAT:Ok INS Sp FiI B)'NTr� VAnMDDEEPF0.i 7FEET.THERCUMUSTBFSLOPMMIWAR ATA45DEGREEANGEABOVE4FEET00. r, S ~ WLUIDE PXCAVAMON-EXCAVATE THE HU BAGTO MI ANGLE OF MOSS—ANGLE AT WHICHTHE SLOPE IS STABLE.UfSUUsV v y BAIXTOAfIOPEOF2.INENFY50LLCOND1T10Nf) 1ST.FLOOR PROPOSED ADDITION: A).AN UNSNo=VDLTICLECUTHIOUFD NOTEXCFED 5 FEET ON A ROPED SITE. DOSTINL STORAGE BIDGL• 6762 Sp.FT 6.7% / TDBALWATERRUNOFF CONDIOL WSOF O. WELLSfAOF SEPTIC IFNEEDED)DURINGCOVPlPFDTgN.LU AAN --SPOU[f TO BE IMMEDIATLY INSLALLFD TTIME OF COMPLE510N OF ROOF.A40pWNSFO1Df TO BE HPFOTO D0.YWEllf AT M.S TMF. ' UNOERLROUNDMOOkI?S(EIECTRIC.WATDL GAS.FfC.)TO AE WfiAUFp. ' TOTAL: 11.1875p.Fi. 11.1% 5 P0.01ER COMRFfIOPS'fLNM GRAOFTOC[WTROL 0.UNOFi DOLFCSIONTp STAY VAIHIN SITE POCH GMDE AIONL PF0.W.FTE0. , DRYWFLLSM0.0.T0 CO�NTAOL UNOGFTHAT CCANNOT STAY WTHINEdiNRBFDR°ADWAVf.LYiTALLGTCH e,VSI:S W.TH �•� - \ DRAWN MHf MS SCALE 1N'-1�0' )03Y M.622,3013 d�X� .^ SI�ET NlLM3ER: PAINIFRTO PRIME AND PAWTALL DODR EOGEf TO AUINTAW CONIRACTCIX SHALL NCITIFY ARCHITECTOF ANY DVCREPANCIEI BETWEEN TIEDMVANLS.THE SPFOFICATIONE ANDTHE i1FUlCONDIf10NR AND 5IULL REOUFSTCVJIIFIGNON BEFO0.ECO.NMFNC"'I'DPJL COhTRARDR SHNF VFNFY ALL GENERAL CONTPAR00.TO COORDINATP A4tTP1L WTH OWNERS fO0.APRROVAL OF ALL GENtRALCO.IIRACTO0.SHALL BF RFSPd�1f13U F00.A11 BU11DING OFPA0.5NiNfINSPSTSOVS F NMTNPFRSWARMNIYANMDR BEWSSECTLDTO VERIFYALLWORR DIM£NDONS ANDCONDRIDNSAT HIBSITE.INCIUdNC BUIIt51NGAND RTECIENUNCES iOR DBLLVF0.Y OF FpUIPMENT AND MA:ERMFLAND REV.EDY ALL DISCREPANCIES WfSH ARCHRECT PNORTO THE COMMENCEMSM O0.OD uATION O:WTAUt ROUGH PUMC.PLU.NriNG,AND INAC PRIOR TO INfULATWG AND SHFFDWCFAG AND tSULL SECURE iHEC WOFlUORTO R[CEMNG fIN,LL PAYM]•R FROM OWNERS. Zoho Sign Document ID:2A768FFA-LESPCYASAYK-WK30CLODWJ-LYL4J4RXLHD81 PGULKN8 Town of Southold December 29th, 2023 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Kabakov Residence, 1700 Park Ave. Mattituck, NY 11952 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.9 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. of: NE[N Great Eastern Services, Inc. .�� o A PO Box 240 Cl 24 Harvey Rd ' YC Riverhead, NY 11901 L w Mobile: 631.235.0189 N Email: jerrygiustra@gmail.com ��A 103443 C4Zoho Sign Document ID:2A768FFA-LESPCYASAYK-WK3QCLODWJ-LYL4J4RXLHD81 PGULKN8 �V elter Island DESIGN E DRAFTING BY: P E F W KK ShHeights ELEMENT ENERGY LLC TO INSTALL A 4.8G KW 50LAR PHOTOVOLTAIC(PV)SYSTEM AT KABAKOV RESIDENCE, REVIEW BY J.M.NABCEP CERTIFIE LOCATED AT 1700 PARK AVE,MATTITUCK, NY 1 1952. Shelter Isiah 05)112-129 THE POWER GENERATED BY THE PV 5Y5TEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH 4 THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS \\ DE5CRIF 10N DATE RPV �ai� �SYSTEM RATING ORIGINAL 12-29-2023 YS 4.8G kW DC 5TC _ a Noyack EQUIPMENT SUMMARY - 12 QCELL Q.PEAK DUO ELK ML-G 10+ 405 WATT PV MODULES 12 ENPHA5E IQ8PLU5-72-2-U5 MICRO INVERTERS CONTRACTOR I IRONRIDGE XRI 00 MOUNTING SYSTEM Jamespo ice® SHEET INDEX ""u°so°RT North Sea s ELEMENT C 470 SOUND AVE Pv-I COVER MATTITUCK, NY 1 195 PV-2 SITE PLAN PKOJ ECT LOCATION LICENSE # G74G I-HI PV-3 ROOF PV LAYOUT LICENSE # 52G89-ME PV-4 5TRUCTURAU DETAILS t 5ECTION5 PV-5 3-LINE ELECTRICAL DIAGRAM ^ ' PV-G LABELS of GOVERNING CODES Additional A ._ , `P NEW 0 A 2017 NATIONAL ELECTRICAL CODE. Certification r 0 2020 RESIDENTIAL CODE OF NEW YORK STATE. ""a "�"`on f- �� n _'� w 2020 FIRE CODE OF NEW YORK 5TATE. May BeB Regwred. m w A5CE 7-1 G AND NFPA-70. yN �" C� UNDERWRITERS LABORATORIES(UL)5TANDARD5 = BOA 103443 05HA 29 CFR 1 910.2G9 •' ROFESSIONP� GENERAL NOTES ELECTRICAL ~ �' F i_ l�> PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT INSPECTION REQUIREr o THE 51TE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE u HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK 2 Z z n AGREE THE SAME. AERIAL. V!Fw LL1 U-J - 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED _ _ C) > APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, Q >--- INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPKOVAL STAMP a/- ILJ z AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, -- -- - g CZ COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES O �L 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO APPROVED AS NOTED __ > Q U ALL RULES AND REGULATIONS OF THE RESPONSIBLE O JURISDICTION. COMMENCING WITH WORK. COMPLY WITH ALL CODES OF ; � 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I I. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR DAT : j-Z`�"2 B.P.# D NEW YORK STATE&TOWN CODES ° o WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE � � m � Q THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS AS REO AND CONDITIONS OF ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND FE a00.� By,.__, - � — � CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT vMl�} 1�� RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, NOTIFY BUILDING DEPARTMENTAT 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY 631-765-1802 BAM TO 4PM FOR THE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT ' DM COVE FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 FOLLOWING INSPECTIONS! 90UTHOi.DT�VTRUS1ffS SPECIFICATIONS. CONSTRUCTION. 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE FOUNDATION-TWO REQUIRED ��• UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING FOR POURED CONCRETE ��pp��►► NY5 CODES*REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING S�TI (InrV 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND ROUGH- FRAMING&PLUMBING CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS INSULATION cl i5cannec�� 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON FINAL-CONSTRUCTION MUST mu5�- �D� d N .T.S. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. BE COMPLETE FOR CO I PROJECT FOR WHICH THEY ARE MADE 15 EXECUTED OR NOT. 14. AT THE COMPLETION OF . .WORK, THE SITE TO BE CLEARED DV�I�- Fe led and r-C44 - r OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE I `� THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR LEFT BROOM CLEAN AND WORK I5 TO BE COMPLETED TO THE AI_I_ CONSTRUCTION SHALL MEET THE EXTENSIONS TO THIS PROJECT 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF RS :UIIIEMENTS OF THE CODES OF NEW EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. YUIiK STATE. NOT RESPONSIBLE FOR PV_ RESULT OF HIS WORK. TAX MAP: 1000-1 23.00-08.00-005.000 Zoho Sign Document ID:2A768FFA-LESPCYASAYK-WK3QCL0DWJ-LYL4J4RXLHD81PGULKN8 LEGEND TAX MAP: 1 000- 1 23.00-08.00-005.000 DESIGN B DRAFTING BY: o EXISTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL NEW PV SUB-PANELS REVIEW BY051 1 N2-1 29 CERTIFIE A/C DISCONNECT COMBINER INVERTERS _ GND ELECTRODE REVISIONS PV MODULE DE5CRJFn0N DATE REV ORIGINAL 12-29-2023 RACKING RAIL O ATTACHMENT POINT ---RAFTERS -ROOF PITCH ANGLE �SUNRUN METER ®VENT OPLUMBING VENT ®SKY LIGHT CONTRACTOR ®CHIMNEY ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. GOOD CONDITION POTENTIAL SHADING ISSUES 7470 SOUND AVE ]TRIM/REMOVE AS NECESSARY MATTITUCK. NY 1 1952 LICENSE # G74G I-HI LICENSE# 52G59-ME OF NEwY �O COP 0 A GAL � J 703443 AROFESSIONP� i PROJECT NAME U_ U w Ln w z Z 6� w Iw — C) > — w ,L z > U o O LLJ �IC O I-- o Q O p Q [� Q SHEET NAME SITE PLAN N 0o VV270 v ')PAXII, _:A_- 240. ci90o� 611 = 1-0I CONSTRUCTION NOTES 210. D120. 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE O 150 SHEET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. S PV-2 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. Zoho Sign Document ID.2A768FFA-LESPCYASAYK-WK3QCLODWJ-LYL4J4RXLHD81 PGULKN8 CONSTRUCTION SUMMARY TAX MAP: 1000-1 23.00-08.00-005.000 DE51GN 4 DRAFTING E (1 2)QCELL Q.PEAK DUO BLK ML-G 10+ 405 WATT PV MODULES ELEMENT ENERGY LLC (DIMENSIONS: 74"X 4 1.1"X I.4") (1 2)ENPHASE IQBPLU5-72-2-U5 MICRO INVERTERS AY' 051112-129 REVIEW er J.M.N cERT ' 29 (3G)ATTACHMENT POINTS @ G4"O.C. MAX. 0° (149) LF IRONRIDGE XRI 00 MOUNTING SYSTEM. REV1510N15 ROOF TYPE: ASPHALT(SINGLE LAYER) In,? I DE5CRIP'nON DATE REV CONSTRUCTION NOTES �V VV 70 Q ORIGINAL 12-29-2023 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 240° �90°F WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 210° D 120° 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH 150° MINIMUM NEMA 3R RATING. 180° 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE S FIELD VERIFICATION. EX15TING MAIN ELECTRICAL 5ERVICEPAN CONTRACTOR ELEMENT ENERGY, LLC. ® ® 7470 SOUND AVE MATTITUCK, NY 1 195 ® LICENSE # G74G I-HI LICENSE# 52G89-ME I TN I ITY M 36"FIRE 5ETBACK/ACCE55 PATH N P N OO AEG YO co �� G GROUNDACCE TYPI � s �O 103443 a w AR0 SS10NP� � rr PROJECT NAVE N Llj 11J CV I J_ 1 U, N Z U W tLJ LLJ } C) Q a-/ LLJ ARRAY# � z 12 MODULES LD > Q U 23°PITCH O 249°AZIMUTH Q E— LEGEND o O < ®c EASTNG UTILITY METER MAIN SERVICE PANEL NEW PV SUB-PANELS A/C DISCONNECT COMBINER INVERTERS GND ELECTRODE PV MODULE PV LAYO U T RACKING RAIL 0 ATTACHMENT POINT ---RAFTERS DRAWING SCALE PROOF PITCH ANGLE eSUNRUN METER I/811 = I 1-011 ®VENT 'NOTE 0PLUMBNG VENT I.)THE ROOF SETBACK/PATHWAY SHALL NOT BE ®SKr LIGHT REQUIRED ON ROOF SLOPE WHERE THE 511EET NUMBER ADJACENT OR OPPOSITE ROOF SLOPE IS THE ®CHIMNEY \/ GLES ACCESS ROOF IN ACCORDANCE WITH R324.G.I ��IDITION P `� —3 EXCEPTION OF 2020 NY5 RESIDENTIAL CODE. —POTENTIAL SHADING ISSUES _-.TRIM/REMOVE AS NECESSARY Zoho Sign Document ID:2A768FFA-LESPCYASAYK-WK3QCLODWJ-LYL4J4RXLHD81 PGULKN8 ITEM DESCRIPTION ARRAY#I LOAD CALCULATION ARRAY#I DESIGN 4 DRAFTING BY: RB Ricl6ie Beam/Boarcl 2"X 1 2" D. FIR ELEMENT ENERGY LLC R Rafter 2"X 10" D. FIR I G"O.0 REVIEW BY J.M.NABCEP CERTIFIE MODULE WEIGHT(Lbs) 48.5 29 (D) Decking_ 5/8" PLYWOOD osl I I -I #OF MODULES 12 Q) Ceilinci Jo15t 2"X 8" D. FIR P,I G"O.C. TOTAL MODULE WEIGHT(Lbs) 552.0 (C) Collar Ties 2"X 4" D. FIR 48"O.C. REVISIONS (H) Horizontal 5 an of R 130"MAX. DESCPJPTION DATE REV TOTAL LENGTH OF RAIL(Ft) 145.0 ORIGINAL 12-29-2023 RAIL WEIGHT PER FOOT(Lbs) O.GB TOTAL RAIL WEIGHT(Lbs) 101.3 #OF STRANDOFFS 39 (D) WEIGHT PER STRANDOFF(Lbs) 2 TOTAL STANDOFF WEIGHT(Lbs) 72 TOTAL ARRAY WEIGHT(Lbs) 755.3 POINT LOAD(Lbs) 21.0 CONTRACTOR TOTAL ARRAY AREA(Sq Ft) 25G.7 ELEMENT ENERGY, LLC. 7470 SOUND AVE ARRAY DEAD LOAD(Lbs/Sq Ft) 2.9 MATTITUCK, NY 1 1952 LICENSE# G74G I-HI WIND DESIGN SUBJECT TO DAMAGE FROM LICENSE# 52G89-ME GROUND SEISMIC WINTER ICE BARRIER FLOOD AIR MEAN (C) SNOW DESIGN Frost DESIGN UNDERIAYMENT y FREEZING ANNUAL LOAD' Speed" Topographic Special Wmdborne CATEGORY' Weathermga line Termite` TEMP` REQUIRED` HAZARDS INDEXi TEMP) (mph) effects wind region debn5 zone'" depth' QF NE(� 20 140 NO NO NO B SEVERE 3 fT MOD TO 15°F YES FEMA 599 5 1°F �P 4g0 A G7G HEAVY ZONE X liCl MANUAL J DESIGN CRITERIA" �H) m W Indoor 2 Elevation Latitude Winter Summer Altitude correction factor design Design temperature cooling Heating temperature N U� heating cooling tempera difference (J) 1 �03443 ture A��FESSIONP� 105 FT 41°N 15°F 8G°F 1.00 70°F 75°F 55°F Wind Wind PROJECT NAME Cooling temperature difference velocity velocity Coincident Winter Daily range Summer humidity - heating cooling we bulb humidity ROOF FRAMING DETAIL 1 C) Lu LU N U_ U 15'F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GR @50%PH z Z For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. w Q W\ _ a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth N Q }- strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible;"'moderate"or"severe"for concrete as IL.1 Z determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. MODULE MOUNTING CLAMP g CZ/ b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction O shall fill in the frost line depth column with the minimum depth of footing below finish grade. 50LAP MODULE d) > Q U C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. STAINLESS 51YEL 3/8" C� O d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined BOLT AND NUT � O �— on a site-specific basis in accordance with Section R301.2.1.4. O Q e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York 3 0 [- CID State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also � see Figure R301.2(1).] NRIDGE ALUMINUM RAIL f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. ALUMINUM"L"BRACKET g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the ALUMINUM FLASHING SHEET NAME Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: i.The accompanying Flood Insurance Rate Map(FIRM), ii.Flood Boundary and Floodway Map(FBFM),and p q III.Related supporting data along with any revisions thereto. STRU C IT U RAL The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. ASPHALT 5HINGLE Roof h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the 5/1 G"x G"STAINLESS STEEL LAG BOLT WITH effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." 2 112"MIN THREAD i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) PENETRATION 5EALED value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." WITH GEOCEL 4500 j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method (EQUIVALENT OR BETTER) DRAWING SCALE (Base 32°F)." k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the AS NOTED jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. SHEET NUMBER n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or lb from ACCA Manual J or established criteria determined by the \ jurisdiction. P V/ —4 o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at MOUNTING DETAIL 1 elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. TAX MAP: 1 000-123.00-08.00-005.000 (") See Figure R301.2(4)B. Zoho Sign Document ID:2A768FFA-LESPCYASAYK-WK3QCLODWJ-LYL4J4RXLHD8IPGULKN8 SOLAR ARRAY ON STUDIO#14.SG kW (1 2)QCELL Q.PEAK DUO 15LK ML-G 1 O+405 WATT PV MODULES DE51GN�DRAFTING BY: (1)STRING OF(1 2)MICRO-INVERTERS ELEMENT ENERGY LLC (1)STRING TOTAL REVIEW BY J.M.NABCEP CERTIFIE 051 1 1 2-1 29 STRING #I _ _ _ _ _ _ _ _ _ _ _ _ _ REVISIONS DE5CPJPTION DATE REV r- ------------ -- -- - - - - - ORIGINAL 12-29-2023 I I 1 ENPHA5E BRANCH MICRO-INVERTER CIRCUIT CABLE TYPICAL ENPHASE IQ8PLU5-72-2-US 240 VAC, I.21 A 97%CEC-WEIGHTED EFP. I NEMA G,UL 1_15TED I TYPICAL I I I N 1 N I I I MAIN 5ERVICE 0I5CONNECT A MAIN 5ERVICE DISCONNECT B CONTRACTOR 5QUARE-D Q22200NRI3 5QUARE-D 022200NR5 240 V.200 A 240 V.200 A I L1 ELEMENT ENERGY, LLC. 1 BI-DIRECTIONAL " ' " 7470 SOUND AVE j UTILITY METER#98303429 O MATTITUCK, NY 1 1952 1 I-PHASE.240 V , N , " LICENSE# G74G I-HI I 2-POLE PV BREAKER 240V,20A LICENSE# 52G89-ME GATEWAY L1 1 1 HALL BE INSTALLED 1 1 AS FAR A5 1O551BLE FROM Ibl N 17 LI G N _2 .I MAIN SERVICE DISCONNECT Y� O A 1 I s n PSEG AOCCT#9 2011 15107 1 t 1 1 Q UTILITY GRID '���o ,yE� 0, �� G �� 1 1 1 1 j AC COMBINER BOX 2 2a0 VAC.60A 20A MAIN SERVICE PANEL A MAIN SERVICE PANEL B NEMA 3R.UL 115TED (17 20 A DOUBLE POLE BREAKER I-P11.3-W 1-Fri.3-W Q �t)34A$ (I)15 A DOUBLE PCU BREAKER ______-_-- 240 VAC 240 VAC G N FOR COMMUNIGT 011 D_VICE I 200 A 200 A OFESSION I I N N I I 1 G G I I I PROJECT NAME j I I EXISTING GROUNDING EL/ ]L LU -----------� i ELECTRODE SYSTEM 0 w w w - E > - ------------------------------------- -------------- WIRE CONDUIT SCHEDULE B_/ Z LLJ CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE DISTANCE > Q 310.15(B)(3) 310.15(5)(2a)/(3c) O I INVERTERS COMBINER PANEL AWG#12 1 2 1 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR 111 559C 0.84 100 FT 1.9G% w OR EMT O Q O �- 2 COMBINER PANEL LOAD SIDE TAP AWG#10 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC 1" 45QC 0.95 50 FT 1.04% O o ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE L15TED BY UL OR OTHER NKTL,AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acit Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO V AND 909C WET ENVIRONMENT. [NEC G90.8(B)(1)]: (lo,max)'(5trin y Len th'(1.25)= 18.1 5 A 3-LINE D I A. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 9 9 ) Modules per String 2 TO,AND LOCATED AS CL05E AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. AWG#1 2,ampacity'Temp Derate= 25.2 A 25.2 A> 18 1 5 A,therefore AC wire size is valid. Modules per Inverter I , 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 12 COMPLY WITH NEC 1 10.2G. #2 Inverter Output Wire Ampacity Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output'(1.25)= 18.15 A Record low temp -I OQC FURNI5H ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACE550RIE5 TO FULFILL AWG#10,ampacity'(Temp Derate)'(Conduit Fill Derate)=38 A Voc Temp Coefficient -0.2497o/gC DRAWING SCALE APPLICABLE CODES AND STANDARDS. 38 A> 18.15 A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS C� G.)WHERE SIZES OF JUNCTION 5OXE5,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, O eratin Current 10.8 A N T THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. Operating Voltacle 37.4 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Max.System Voltage 49.G V SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 14.0 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEK LUG OR IL500 G5L-4D5T LAY-IN LUG. AC SYSTEM SPECIFICATIONS SHEET NUMBER 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) Max AC Output Current I8.1 5 A PV-5 OR O eratin AC Volta e 240 V 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1000-123.00-05.00-005.000 Zoho Sign Document ID:2A768FFA-LESPCYASAYK-WK3QCLODWJ-LYL4J4RXLHD81 PGULKN8 DESIGN&DRAFTING BY: SERVICE METER I O INSTALLATION NOTE ELEMENT ENERGY LLC SOLAR PV SYSTEM I PHOTOVOLTAIC fPHOTOVOLTAIC ( 1 ) ALL LABEL SHALL BE IN oslllz-STALLED IN REVIEW BY J.M.NAB12PCERTIFIE 9 EQUIPPED WITH SOLAR BREAKER ° 10 • • ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® •• • • REQUIREMENTS. RevisioNs DE5CRIFTION DATE REV OPERATING • •, (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 12-29-2023 MAX SYSTEM SOLAR AC LOAD CENTER - OUTSIDE +DOWTRELOCATETM •. VOLTAGE � REQUIRE FIELD VERIFICATION. I ovecumwMMIX ` (3) LABELS, WARNING(5) AND MARKING 0 n,R MMSHUMMSwm +M O SHALL BE IN ACCORDANCE WITH NEC TIflarPoslna+MSlw"M I 1 0.2 1 (B). I PV SYSTEM AND REDUCE 4 UTION SHDCKNALMMIN THE AMY AC DISCONNECT POWRroTMsA�RvtcEtsuW (4) THE MATERIAL U5ED FOR MARKING FROM nE FOUOMMG SOURCES WrH `n`° lwAsS..Xw MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - INSIDE mME" COMPLIANCE WITH NEC 1 1 0.2 1 (B)(3). coNTRACTOR w�r� (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLC. ARN1N 7470 SOUND AVE ® O7 ® 1 I '� SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1 195 � 0F� DUAL POWER SUPPLY ? ! OVERCURRENTDEVICE.S,E7A10NGl SOURCES:UTILITY GRID • COMPLIANCE WITH NEC 690.3 1 ucENSE # E746I-t11 MAwSUPPlravERMI RMT + AND PVSOLAR LICENSE # 52689-ME DEVICE.SPAL NOT EXCBM ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING "MAgTYOFWSBAR OF NEW J- -— THIS SERVICE METER W t IS ALSO SERVED BY A ELECTRIC SHOCK HAZARD IRTOVOITAK;SYSTEM PHOTOVOLTAIC SYSTEM _ TERMINALS ON Tiff LINE AND COMBINER PANEL -- N LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS 103443 A CONDUIT - OUTSIDE BUILDING -- IN THE OPEN POSITION �SS►ONP� ® PROJECT NAME tf� "MAALPOWER SUPPLY :i z z O> w Iw w ISOURCES:UTILITY GRID AND F— — PV SOLAR ELECTRIC SYSTEM I (� > — MAIN SERVICE PANEL - OUTSIDE Q A CAUTION SOLAR CIRCUIT O -- - g � � z &CALMON _ ' � � O < SOLAR a EcTmc SYSTEM COMECTEO' ma 6LU • o m O ~ Q [� Q MAIN SERVICE PANEL - INSIDE OPERATING �—/ — POWER SOURCE OPERATING •LTAGE • i OUTPUT CONNECTION A\ O DO NOT RELOCATE THIS --`?NAve OVERCURRENT DEVICE LABELS AC DISCONNECT/BREAKER DRAWING SCALE OOO � � N .T.S. 11L -1 vµ PV-6 TAX MAP: 1000- 1 23.00-05.00-005.000 ZAf& IRON RIDGE Flush Mount System ;.r -4- 6i Built for solar's toughest roofs IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified QAll components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty ® Entire system and components meet Twice the protection offered by newest effective UL 2703 standard. competitors. XR10 Rail XR100 Rail XR1000 Raid Bonded Splices A low-profile mounting rail The JbIackfinish ential A heavyweight mounting All rails use internal splices for regions with light snow. solail. rail for commercial projects. for seamless connections. • 6'spanning capability 8' ability • 12'spanning capability Self-drilling screws • Moderate load capability Heability • Extreme load capability Varying versions for rails • Clear and black finish • Cl finish • Clear anodized finish Forms secure bonding Clamps & Groum UFOs �, Stopper Sleeves Grounding Lugs Microinverter Kits F , Universal Fastening Objects Snap onto the UFO to turn ys to Mount Mls or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled & lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 Attachmer,' FlashFoot2 Conduit Mount Slottv4 L-F0et Bonding Hardware AIL Flash and mount XR Rails Flas d mount conduit, - esign for rapid rail Bond and attach XR Rails with superior waterproofing. ut, or junction boxes. attachment. to roof attachments. r • Twist-on Cap eases insfall • Twist-on Cap eases install • Secure rail connections T& Square Bolt options • Wind-driven rain tested • Wind-driven rain tested • Slot for vertical adjusting Nut uses 7/16"socket • Mill and black finish • Secures 3/4"or 1"conduit • Clear and black finish Assembled and lubricated — Resources Design Assistant , NABCEP Certified Training Go from rough layout to fully Earn free continuing education credits, engineered system. For free. while learning more about our systems. powered by - ouop YR � � D TOP BRAND PV Fa,iro� Warranty 2U21 a CELLS Product 8 aerform— Yield SeCwity T_ BREAKING THE 20%EFFICIENCY BARRIER nn�ll Illlnllll�III O.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV'of S�V the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,9- Y Y Anti PID Technology',Hot-Spot Protect and Traceable Quality Tra.QTM". EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warrantyz. APT test conditions according to IEC/TS 62804-1:2015,method A(-1500 V,96 h) 'See data sheet on rear for further information. THE IDEAL SOLUTION FOR: `�U/ Rooftop arrays 69 residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION -mat 74.0in x 41.1in x 1.261n(including frame) (1879mm x 1045mm x 32mm) "A j1f/8n"1 ar(ana• ) 4v9 ght 48.5lbs(22.Okg) 492(1250-) •or+Cc ,-r 0.13in 3.2mm thermally 9-�- -.____.--.-- a.o,and,so.�a•air a.amnl� r,... ( ) yprc-stressed lass with i anti-reflection technology 39ck:'',ov9r Composite film a r(aie•.) =am.e Black anodized aluminum au•(ias,,.,,1 6 x 22 monocrystalline a.ANTUM solar half cells 1.lx 2.09-3.98itlA1.20-2.30iiir0.09-0.71in -- -- �� (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes ;ab�e 4mm2 Solar cable;(+)2!49.2in(1250mm),(-)>-49.2in(1250mm) 'p`� ■•a+w•�. --- - _ a.wununy■ww1oETAxN # Cor^actor Stgubli MC4;IP68 L I32-) DETAIL 0.6i7(Iemn) s.■r(za.smm)I Is.sr(ea,...) ELECTRICAL CHARACTERISTICS POWER CLASS - 385 390 395 400 405 CAiS ST C'AIER-0IERA'4CE+54Vi-0W; =;•v9 at tf=�> pum [W] 385 390 395 400 405 -y- -,ut )rrs t• ------ - Isc -[A].._-- --. 11.04 11.07 11.10 -- 11.14 _ - 11.17 �canCimuit'Voltage- Voc IV] 45.19 45.23 45.27 45.30 45.34 cjr•em at MPo IMvr -- [A]-"- -- 10.59 10.65 10.71 10.77 10.83 vo,tage at MPP VMPP _ (VI - --36.36 36.62 36.88 37.13 - 37.39 -E`ric.e^cy' n 1%]----- >-19.6 t19.9 >20.1 2!20A -- ->20.6 %I!VA,IjM�c;FCRMANCE AT vCRMA_0PEKA'!N3 ., 3 %2cws•at V;0D PMPF [W] 288.8 292.6 296.3 300.1 303.8 S u' c.;I`Curra, Isc [A] 8.90 8.92 8.95 8.97 9.00 ^.�_: t•rortags Voc IV] 42.62 42.65 42.69 42.72 42.76 Ca re., a;%I'�s -----IMM --[A] --- 8.35 -- - 8.41 8.46 8.51 8.57 raga a-Vc ^� VMPP IV] 34.59 - ~-- 34.81 35.03 - 35.25 35.46 •Measurement tclerarces Pv„33%;Ix;Voc t5%at STC:1000 W/m',25 t2`C,AM 1.5 according to IEC 6C904-3.2800 W/m2,NMOT,spectrum AM 1.5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ------------------------- At least 08%of nominal power during 7 se _ ------..b----- -------- degomntionper yea.At least 93At% '■■ - - ,! first year.Thereafter max.0.5% Po P y �� ------ a 25 ears. least 86%of nominal power up to u p r r - - - --- i All data within measurement tolerenc- L es.Full warranties in accordance with ■■ am 400 ■ea we 3000 b0 the warranty terms of the O CELLS sales organisation of your respective • ■ u u a s country. Typical module performance under low inediance conditions in xn�,O'�+P�✓�ancgcT^lOtn As sipw.u.Tra) comparison to STC conditions(25'C,1000 W/ma) - TEMPERATURE COEFFICIENTS a 79'roeratur9 Coaffic!ant_ d [%/K] +0.04 7imaerature Coef'iciart or s.,,. 9 [%/K] -0.27 'i,rr,rai ModOe CoeraVngTemper3turs NMOT [•F] 109t5A(43t3•C) m '9mparsturs CcaFfic)e-t c*--- _ y [%/K] - -0.34 - - n PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage ti5,5 IV] 1000(IEC)/1000(UL) P`i rscdu!e asssificancr Class II p Maximum Series Fuse Ratirg [A DC] 20 Firs RaCrg based on ANSI!UL 81730 TYPE 2 Max.Ossign'_oad,Push/Pull' [Ibs/ft2] 75(3600 Pa)/55(2660 Pa) ^rarmitted Module Tempe-ature -40•Fupto+185•F c Max.Test Lead,Push IPu113 [Ibs/ft2] 1.13(5400 Pa)/84(4000 Pa) on Continuous Duty (-40•Cuptc+85•C) e 'See Installation Manual U U QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION _ o SIM ] g UL 61730,CE-complient, Quality Controlled PV-Tl1V Rheinland, ® w IEC 61215:2016,IEC 6173a.2018, L U.S.Patent No.9,893,215(solar cells), S� C E Tau■r+.,e Horizonxal 76.4in 43.3 in 48.0in 1656lbs 24 24 32 QCPV Certification ongoing. CCr•a■•Us c_a=kzglrg 1940mm 1100mm 1220mm - 751kg pallets- pallets modules _ ur Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Henwhe O CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 961 EMAI L inguiry@us.q-cells.com I WE 8 www.q-cells.us n ENPHASE 108 and I08+ Microinverters Easy to , Our newest 108 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-piay connectors power to AC power efficiently.The brain of the semiconductor-based microirverter Power Line Comauxicaticr is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster irstaliatior:with simple to changing loads and grid events,alleviating constraints on battery sizing for dome txc-'moo cabling energy systems. High productivity and reliability (Produce power ever, nher the Eriphase grid is down' 25 More than one million cumulative hours of testing Class Il double-insulated Part of the Enphase Energy System,I08 Series 028 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one miMcn cumulative Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- and analysis software. leading limited warranty of up to 25 years. powered PV modules Microgrid-forming ® Complies with the latest advanced grid support" Remote automatic updates for the latest grid requirements Connect PV modules quickly and easily to IQ8 Series I08 Series Microinverters are UL Listed as Rapid Shut Down E Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rap Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) requirements ®2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I408 Microinverters,and other •Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. `•I08 and I08PIus supports split phase,240V I08SP-OS-0002-01-EN-US-2022-03-17 installations only. IQ8 and IQ8+ Microinverters Commonly used module pairings' w 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/12C half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range v 25-46 25-58 Min/max start voltage v 30/48 30/58 Max input DC voltage v 50 60 Max DC current2[module Iscj A 15 Overvoltage class DC port 11 DC port backfeed current MA 0 PV array configuration tx1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range" v 240/211-264 Max continuous output current A 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% Overvnitage.class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85leading-0.85lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -400C to+600C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38lbs) Cooling Natural convection-no fans Approved for wet locations yes Pollution degree PD3 Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to defire the number of microinverters per branch ir,your area. 108SP-DS-0002-01-EN-US-2022-03-17