Loading...
HomeMy WebLinkAbout50921-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATION'S UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50921 Date: 7/10/2024 Permission is hereby granted to: 530 Hiawathas LLC 112 Green St South James port, NY 11970 To: Install accessory stand-by generator at existing single family dwelling as applied for. Maintain minimum 10 foot setback to side / rear property lines. At premises located at: 530 Hiawathas Path, Southold SCTM # 473889 Sec/Block/Lot# 78.-3-27 Pursuant to application dated 5/15/2024 and approved by the Building Inspector. To expire on 1/9/2026. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CO-RESIDENTIAL $100.00 Total: $325.00 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT ���, Town Hall Annex 54375 Main Road P. O. Box 1179 Southold NY 11971-0959 � '� Telephone (631) 765-1802 Fax (631) 765-9502 Date Received PERMITAPPLICATION FOR BUILDING For Office Use Only ���� LE "I L ' PERMIT NO. 5 +;� Building Inspector: - MAY I 20P4, -- Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: J OWNERS)OF PR PERTY: Name:530 Hiawatha Ilc 1ECT:m # l000-78-3-27 Project Address:530 Hiawathas path, Southold, ny Phone#:8456645696 Email:burtdorfman@gmail.com Mailing Address:112 green street, SOUTH JAMESPORT, ny 11970 CONTACT PERSON: Name:burt dorfman Mailing Address:112 green street, SOUTH JAMESPORT, ny Phone#:8456645696 Email:burtdorfman@gmail.com DESIGN PROFESSIONAL INFORMATION: Name: I Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:530 Hiawatha Ilc Mailing Address:112 green street, SOUTH JAMESPORT, ny Phone#:8456645696 Email:burtdorfman@gmail.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: EOtherinstall generator Qg Will the lot be re-graded? Dyes R No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property:single family home Intended use of property:single family home Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to r40 this property? ❑Yes ❑No IF YES, PROVIDE A COPY. 8 C"heck Box After Readi:)g: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. burt dorfman Application Submitted By(print nam ®Authorized Agent BOwner Signature of Applicant: ' .. — Date: May 1' , 2024 STATE OF NEW YORK) COUNTY OF ` ,) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the "1 5—13J !�h a (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is du authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this J day of 20 t,!V E L.GATZ-SCHWAMB0RN NOTARY PUBLIC.STATE OF NEW YORK 028 PROPER"!„ ,,,, OWNER I ,,,�,,,,HORIZ „°i Registration Suffoto. A6ounty (Whe Qualified in Expires Dec.County re the applicant is not the owner) Commission ExPiocs C3e 24.20 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765 9502 gf g U, APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: May 15,2024 Company Name: 530 Hiawatha Ilc Electrician's Name: Triangle Electric License No.: 4468E Elec. email:ccecontractors(9 opton line.net Elec. Phone No: 6318312582 DI I request an email copy of Certificate of Compliance Elec. Address.: p.o.box 61, St. James, ny 11780 JOB SITE INFORMATION (All Information Required) Name: 530 hiawatha Ilc Address: 530 Hiawatha's path, Southold, ny Cross Street: nakomis street Phone No.: 8456645696 Bldg.Permit#: ' email:burtdorfman gmail.com Tax Map District:_ 1000 Section:78 Block: 3 Lot:27 BRIEF DESCRIPTION OF WORD, INCLUDE SQUARE FOOTAGE (Please Print Clearly): generator S uare Footage:, Circle All That Apply: Is job ready for inspection?: YES NO [_]Rough In El Final Do you need a Temp Certificate? YES NO Issued On Temp Information: (All information required) Service Sized PhF]3 Ph Size: A # Meters 1 Old Meter# ❑New Service[]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals ✓ 1 2 0 H Frame M Pole Work done on Service? Z Y N Additional Information: PA DUEUE WITH AP PLICATION ON S.C.T.M. NO. DISTRICT: 1000 SECTION:78 BLOCK:3 LOT(S):27 - �� - HIAIPATHAS� PATH aP.�y w.v. 12a.43` S I}�a0isP U 1# N e4°21'00"E - M:v. 0 pi ORv V.'�1 - i is o [ d " 115 s ss L la MRENw . , � DRY . S QPA PAW °1�EP MOW r 1r 110.00 mvc/aPAID 0 wa ZONED R-40 110.00' NON-CONFORMING CORNER LOT 1 ? FRONT YARD:40' MIN S W21'00"W SECONaW FRONT YARD:30'MIN c SIDE YANG: IS' MIN REAR YARD:50'MIN W fi SUPPLY%VJA ORYWRIS AAA CESSFIOM LWAMW SNOW ARE nM I=OUSERVVAUMSYS AND OR DATA OBTAINED FROM ORIERS SANITARY LOCATION AREA.-27,333.13 SOOT.or 0.63 ACRES_._... _.._ -. AEAVAIMa4nM - DRAINAGE CALCULATIONS: AA sr ' ALFiRA&�[OS ADR2t2PI TO TNT W�A4 A 3(iCATXYI P P`7fAF"NEY; STAY€E +[l LAM or TAEC sw" A)DWELLING w/COVERM PO H-2210 SO.FT. t3.,0. 62.V 37 ltiw T?1E tA€AS - [RAC NDF Dk' _ -.. dO e€A wtL DNA DOPY. - RL2V AMP MUL 221E A D.fE8�367.&7 C 3MloF REGUIRFD a # -. n '3'dRa€Y'•6 A DV TD nA; OOiPANK - A VGY AM to~ _ (J)!'D(A A 3'DEEP ORYwD.-MW PROVIDED LOi ST' d2.5 A�t0 TYi` Dr THE AEA A twr�s .-.. L at`2 43 50.5 3NDdF1 NDF€&N FR911 FRgE'4YY Lam'FD A A t - ky A I 5& 49 AST AY7$Y@ TD AV IlNES OY TG n:€ a F A tS AAOlLVY A#' or - _ ARr ADr Yfw&r m A Ar——- Y LCA se amm an DESCRIBED PROPERTY CERTIFIED m 5 0 L1MAT A Q YAP OR FILM 9NATED An SOIRNOLD - AS-BUILT SURVEY 05-01-24 TOEN OEM SOUTHOLD FND LOC. 09-27-23 SUFFOLK COUNTY,NEW YORK Y 13 SURVxTEFG" REVISED 08-23-23 �. m aft 10 A Nw T-kO 11931 REVISED 09-22-22 FEE/222-76 sum 1'-30' DATE:JUNE 5,2022 xY.S,.,n.: Emu(aEPm-� VAX(01)�E� REVISED DECK/CELLAR ENT. 05-23-22 �. t-7 GENERAC 0 GUARDIAN° SERIES ®/ Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power'" Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 M 60 Hz • Two-line multilingual digital LCD Evolution TM controller (English/Spanish/French/Portuguese) • 200 amp service rated smart switch transfer switch available • Electronic governor • Standard Wi-Fi®connectivity • System status&maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation GENERAC• 5 Year limited warranty - • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.* - *Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. �'� 11 or CUP- E nv' ry 1 ooc "U-1 1„lb-i Ui ui riuv✓.(Jai Note:CErL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ErL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at-*1%. O TRUE POWER'"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Lang life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINKO' CONNECTIVITY:FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. NERAC PROMISE ' ,mm*nuumo�ro�wc+a GENERAC® 20/22 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows fora smaller,lightweight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to_0%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 311 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution— Controls • AUTO/MANUAUOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD display Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC® 20/22 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet, or computer at any time via the Mobile Link application for ' complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. i GENERAC® 20/22 kW Specifications Generator Model G0070384,G007039-1 G007042-Z G007043-2 G007038-3,G007039-3 G007042-3,G007043-3 (20 kW) (22 kW) (20 kW) (22 kW) Rated maximum continuous power capacity(LP) 20,000 Watts" 22,000 Watts* 20,000 Watts* 22,000 Watts* Rated maximum continuous power capacity(NG) 18,000 Watts" 19,500 Watts* 18,000 Watts* 19,500 Watts" Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 Total Harmonic Distortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) 448/203 466/211 436/198 445/202 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load** 67 67 67 67 Sound output in dB(A)at 23 It(7 m)with generator in Quiet-Test'"low-speed exercise mode** 55 57 55 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx.1.9 qt/1.8 L Operating rpm 3,600 Fuel consumption Natural gas ft3/hr(m3/hr) 1/2 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) Full Load 301(8.52) 327(9.26) 287(8.13) 306(8.66) Liquid propane fO/hr(gal/hr)[Mr] 1/2 Load 87(2.37)[8.99] 92(2.53)'[9.57] 86(2.36)[8.95] 92(2:53)[9.57] Full Load 130(3.56)[13.48] 142(3.90)[14.771 136(3.74)(14.15] 142(3.90)[14.77) Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas. For BTU content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interlace for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard RurVAlarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Faull/Missing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Ovedoad/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard **Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby.Applicable for supplying emergency powerfer the duration of the utility power outage.No overload capability is available for this rating.(Ail ratings in accordance with BS5514,IS03046 and DIN6271).*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine powerand condition,etc.Maximum power decreases approximately 3.5%for each 1.000 it(304.8 m)above sea level;and also will decrease approximately 1%for each 10°F(6"C)above 60°F(16 QC), GENERAC® 20/22 kW Switch Options Service Rated Smart Switch Features G007039-1(20 kW) _ • Includes digital power management technology(DPM)standard. Model 0007043-2(22 It" G007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. 0007043-3(22 kW) • Up to eight additional large(240 VAC)loads can be managed when used in No.of poles 2 conjunction with Smart Management Modules(SMMs). Current rating(amps) 200 • Electrically operated,mechanically-held contacts for fast,clean connections. Volta,ge-rating(VAC) 120/240,10, rated,both inductive and resistive. utility voltage monitor(fixed)* • Rated for all classes of load,100%equipment -Pick-up 80% • 2-pole,250 VAC contactors. -Dropout 65% Return to Utility' Approx.13 sec • Service equipment rated,dual coil design. Exercises bi-weekly for 5 minutes* Standard • Rated for both aluminum and copper conductors. EFL or UL listed Standard • Main contacts are silver plated or silver alloy to resist welding and sticking. Enclosure type NEMA/UL 313 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting Circuit breaker protected 22,000 flexibility. Lug range 250 MOM-#6 *Function of Evolution controller Exercise can be set to weekly or monthly Dimensions w1 200 Amps 120/240,18 Open Transition Series Rated Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 691 � H1 GM 67.95 76.45 26.67 34.29 J�d Wire Ranges Conductor Lug I Neutral Lug Ground Lug 400 MGM-#4 1 350 MGM-#6 2/0-#14 ' DEPTH i—w2—1 y GENERAC® 20/22 kW Available Accessories Model# Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact®). G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(-18°C). (Not necessary for use with AGM-style batteries). r G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regulady falls below 0 OF(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not Contact Kit be needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,con- (Standard on 22 kW) toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corro- sion.The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring Monitor the LP tank's fuel level is an importantstep in verifying the generator is ready to run during an unexpected powerfailure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large G007006-0(100 electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can amp) reduce the overall size and cost of the system. G007169-0 Mobile Link®Cellular The Mobile Link family of Cellular Accessories allows users to monitor generator status from anywhere in the world, Accessories using a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. Dimensions & PCs Model UPC 637.6 mm 1216 mm G007038-1 696471074185 ]zs.,In] [as.o m] G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727.2 mm G007042-3 696471074208 126.6 1"] G007043-2 696471074215 G007043-3 696471074215 O O 646 mm 1232.. [25.5 in] [46.5 Im LEFT SIDE VIEW FRONT VIEW Dimensions shown are approAmate.See installation manual for e]act dimensions.00 NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ZONNESEMN ©2020 Generac Power Systems,Inc. All rights reserved.All specifications are subject to change without notice.Part No.A0000221268 Rev.B 05/28/2020