HomeMy WebLinkAbout50914-Z " ...� TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 50914 Date: 7/9/2024
Permission is hereby granted to:
220 Navy St Trust
79 W 12th St Apt 10A
New York, NY 10011
To: Install accessory standby generator at existing single family dwelling as applied for.
Maintain minimum 5 foot setback to property lines.
At premises located at:
220 Navy St, Orient
SCTM # 473889
Sec/Block/Lot# 26.-1-25
Pursuant to application dated 5/29/2024 and approved by the Building Inspector.
To expire on 1/8/2026.
Fees:
ACCESSORY $125.00
ELECTRIC $100.00
CO-RESIDENTIAL $100.00
Total: $325.00
1111Y�
Building Inspector
� TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1 179 Southold, NY 1 1971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 hrtt �:// rww. �utholdlownrr .��o ,
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only a
PERMIT NO. Building Inspector: MAY 2
Applications and forms must be filled out in their entirety. Incomplete
PP Y �
h wner,an
e ted. Where the Applicant is not the o ...,.,. .
applications will not be accepted. , .
Pp
p PP
Owner's Authorization form(Page 2)shall be completed. -
Date:05/29/24
OWNER(S)OF PROPERTY:
Name:Susan Pelzer SCTM # 1000-26-1-25
Project Address:220 Navy Street Orient NY 11957
Phone#:646-823-6934 1 Email:susan.pelzer@gmail.com
Mailing Address:220 Navy Street Orient NY 11957
CONTACT PERSON:
Name:AMP Architecture
Mailing Address:P.O Box 152 Mattituck NY 11952
Phone#:631-603-90,92 Email:bepperson@amparchitect.com
DESIGN PROFESSIONAL INFORMATION:
Name:Anthony Portillo AMP Architecture
Mailing Address:P.O BOX 152 Mattituck NY 11952
Phone#:631-603-9092 Email:aportillo@amparchitect.com
CONTRACTOR INFORMATION:
Name:.
Mailing Address:
Phone#; Email:
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
DOther Generator Application $3,000
Will the lot be re-graded? ❑Yes *No Will excess fill be removed from premises? ❑Yes BNo
1
PROPERTY INFORMATION
Existing use of property: Single Family Residence Intended use of property:Single Family Residence
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R-40 NC this property? ❑Yes @ No IF YES, PROVIDE A COPY.
8 Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water Issues as provided by
Chapter 236 of the Town Code, APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Bulldtng Zone
ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations;for the construction of buikfings,-
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary Inspections.False statements made hen_ln are
punishable as a Class A misdemeanor pursuant to Section 230.45 of the New York State Penal Law. '
Application Submitted By(pript name); ��1� ' ����I� i7Authorized Agent ❑Owner
Signature of Applicant: Date:
STATE OF NEW YORK)
SS:
COUNTY OFyo ) II
`l
,being duly sworn, deposes and says that(s)he is the applicant
(Name of individual ignin contract) above named,
(S)he is the
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of 202�L _In aw_
Nci Pu i
AUTHORIZATIONPROPERTY OWNER DARCEE AUFENANGER
(Where the applicant is not the owner) _ NOTARY PUBLIC,STATE OF NEW YORK
Registration No.01A00019644
Qualified in Suffolk County
1 220 Navy Street, Orient Commission Expires January 9,2028
residing at
do hereby authorize AMP Architecture to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
I
; f BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
Town Hall Annex - 54375 Main Road - PO Box 1179
tea .
Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
m "amesh southoldtownn . ov — seand southoldtownn . ov
a.,..
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date:
Company Name:
Electrician's Name:
License No.: 22 Elec. email:
Elec. Phone No: ? 1 request an email copy of Certificate of Compliance
Elec. Address.:
JOB SITE INFORMATION (All Information Required)
Name: �� /v�U ��, 7-P/S�-
Address: 2goCross Street:
Street:
Phone No.:
BIdg.Permit#: email:
Tax Map District: 1000 Section: (p Block: Lot:
R1EFOESO tON-OP7ORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
. � Square Footage.
Circle All That Apply:
Is job ready for inspection?: El YES [] NO Rough In Final
Do you need a Temp Certificate?: F] YES EJ NO Issued On
Temp Information: (All information required)
Service Size 1 Ph[]3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 1 2 H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
Z L��r���_.o�,.. �
F ELRs1DER
E
IK-
-IT
Sf I.G.I aCYll�r
5
t- LO
cr
jl/
025 T,10�z'r r !rfi T xv T .�,�..V� 1 .. ,. ............�.... ,OCa GIBL.Om"�'rL,}'v"lA djQFV;'z ,,-I'fD
E'Kt t c
7 k ...._.._._._...
y�^ 4 y • a1-c7iF Nfl ll GI TI9 6 47 n
k �w
Liz ¢ c„ r
y"
T ` Wl j
132 � �"".- w�' ° T��, ,• .�,.,.�,.,.,r.. � .�� f�
.� � u )a �
e�=v.s � v�rlrcr.�c, art• � ..
,
1.0
L26 m
��, �u J=cT
LOCATION fi IAr"""•
i l ttw' C rtt c ................... .W.W...............�.. ......... .,.,,
{ !C cl 11115KNOW I IAYJ I,'I`c .., ... .... ... .m.11 pp •".��� ........ ^`I f "e'..... .. .......
{4.1 �1� +., 47 ,,--r N cx MAOICIJ.K- O X�Pl,:,'; ti, )i"w,4....�"�.II-- ....+ ��,71..✓T;/ ,7.._..., ..... .... ..• .,..........w. ...,,.._.,.�...
1 10 1 rv^n_4ur$I r lxa n..¢!.�n >iti..Icx,.prt.t
vril. l�sr.,.�a d, ali I I'llr e: ,rr ...
,�� l..lv'!'�'i.'N I.G..C...I,Ih'..AN -Vr,s.W1::�'✓l et= `s� ✓ µ� � .., y I �
n�- IIr .-d s r IIII/ y 4 rylt bTA11. rr;�.rer.:we,1a Y GC7VC L7 �'(J ,OR� FRAME -f'JUS- ✓'7, `"aGftiEV r�'C?6'C.H A'.�D .'r" II.GO SREPROJPLAN&ZONING DATAECT LOCATION PE _•_Ji
ql
. n
.r„n A r caulia�..r .Nn`.Ilurrt 2 —XIS--, " - - c, 7 ... H. r m W '
X 114C S I O�Y T�.AMC HO ..E I O BE '"""M�LIS,IE� w
le . XS—IhC� F .AME 5HEDS TO BE RE�OVE� ®,,,,® �C �1 4Mp
a�i ,
0-002,00 GENERALNOTES
a. FROF'OSEP '!A OATS
ENERGYTA
...........
....-.._.-.._(EY..._.O-...T......H..-..R. 5._)
IT ... i , LE
F�( Jp . I CV' I STRUCTURAL D ESIGN CHARTS
....._ I( c1c)W`i C10 HOLDOWN,ANCHOR BOLT �,.._ ...,, ....-
r. II Ia,7 A i .....
STRAPPING,&NAILING DETAILS
c `
_. 1 r , r•,;y r y! ..r= I „ ..,. .art k "w,, FASTENING SCHEDULE
" 9 I nse p we r�r r I FRAMING GRAPHICS
I o., P.,I d•, nr r 1 BEAM CONNECTION PATTERNS
n
I I < I can v P;rt ..i �, rt � I � FIREBLOCKING DETAILS
�` ,..... _.
m , IYfy - -• .�n. ...... _. + --0I.00 PROPOSED FOUNDATION PLAN
an
.0 ul c r
+. ...a
HV API
PROPOSED FIRST FLOOR PLAN
u
Fr7
r - A—lO�:.O✓ I
, c>
,...,, I r �.,,,r e.c'A•I:A.a o: ,......... 1 rnw•a
»•L: _ it f =. Iw rd n.I n �... a I ...... .... .. ... ..._.
"•`- z r-e "- l�r rr..�,, .00 PROPOSED SECOND FLOOR PLAN
nw,..A'rrarAl I,rorc a Ip a a,e a I ,6y_�("j C} '} PROPOSED EXTERIOR ELEVATIONS
N A V Y" U T R E E T it1 as t o err* f
at n,x n
a 41.A knraLn. ......., l td 1 1-. � 1�i.,e ,1 �A-202.00 PROPOSED EXTERIOR ELEVATIONS
c .a
I
runt r I
PELZER
SITE PLANm'__...:. "- ......... ......... .......,.,,,. .�,_. .... ,,,,,,... __ . r� 01 00 BUILDING SECTIONS ...,.,...
RESIDENCE
�:x HOLIF.:laA";", �LoT ccvezA 220 NAVY STREET
______
..vM _ ORIENT NY 11957
Y "w Xll I'ICACd( YOTI'"°k'LI\'...) nwztn
—_
aMcx'acr I a cr I ,ru '_. DESIGN DETAILS
L T rae
TO A I ell+ j r e.r r 1 0R'A1wpv'ING TRTLE:
'* "'T^.`^4 W •: " PYd.«""4,r,GSr.H N IN 1..ivdrtt VY/aC 5''d5rr ..._ _� m ., ,,,.. I ..
n,a0 I1
rw u"na.a [ PROJECT LOCATION&SCOPE
"a e, r nd s ISO coy I n51 f POP_O.SED,ST R.,aU.CTRAL PLANS SITE PLAN&ZONING DATA
� .s..
10"Al.nr r!w n ALL a r ! Il.,cr`,1 o•d.A 2PROPOSED STRUCTURAL PLANS PA.wL.
S,r aI e .p rt ,. EG /�0®1.00
...
.a I r+,h I W.. n�I I:nrEc 4
! , �I tau c
c) PROPOSED STRUCTURAL PLANS bA rL 12(OJ122 ..
. � II
1 OF 15
. ,.I
I taut znc p1 � m• � .. :
1 `✓: YI.A,I'I Y C. I,.[A POOL rJI h L.,J'�.!;.'.x .. ...............................
... ... .............�.........� J YY .... .`ii..Q r9 U YI^••., .�. ___ .,
rlt r `J- 0�r.CO PROPOSED STRUCTURAL PLANS
ry .� J �. < "Y!wltGfv Y Y"
C VI (r 'M'l Iv N� W. 4 ....
r a x r wr^,. n,.LLrt Ira a." m rn y r . � xc t �, v ra' •y:r e
W.
t: nr u
JUL
,.1w. p ,u•1r��nlIa �•n,w.A.N S L, �,«m^t I,r, uh:rya r,a...l..,,,s I,earzr, c�,Ir+utera..r r I,1 el e L,.k. p- 0 .0° GAS RISER
RTER SUPPLY RISER L .4. e 'av7�Y`titl
la a :r vle,1.I.,C IC, ar , ru Ir✓ mw a IIr III nl1I:: Ia rre.� Ir'A..a a,...
r. hinn a zHx K zrx+lc Jrrvr'f J n -r lieuW...r 1 anrr a o x t awml
e Iv II r a n,1uq v c Iwa a I al !rn.a.y.^,n. z rnc,. du I HIN n n�,o-u Inv nr':! ��4$,r✓Pd.e �'..
111 I H:,1110111,'l TI Yl N I.V,"l' HI
V a{fY`tlx Ti w fl Tl
e`.1 AYk nN IP'C MMrC.l AL J41 F rC IVr;A 4 I> I'.:n. It' u^..1 IV^.Vf 19L JA
b�
GENERAC'�. so(.S
GUARDIAN® SERIES
�Zz� � Residential Standby Generators
Air-Cooled Gas Engine
Standby Power Rating
INCLUDES: G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz
• True Power*" Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz
gy G007209-0,G007210-1 (Aluminum-Bisque)-24 kW 60 Hz
• Two-line multilingual digital LCD Evolution*"controller
(English/Spanish/French/Portuguese)
• 200 amp service rated transfer switch available
- • Electronic governor
• Standard Wi-Fi®connectivity
<uRti';•{'.` uV,.^.r'V.','..�,'' ..Vow,T'i,4+��'�3.}�,�^^a.:. `�
• System status&maintenance interval LED indicators .;fl•: H,^ r;.r .
• Sound attenuated enclosure
• Flexible fuel line connector
• Natural gas or LP gas operation GENERAC
• 5 Year limited warranty °z_ ?'' '> �" 'Z i
[
• Listed and labeled for installation as close as 18 in(457 mm)to a
structure.,
*Must be located away from doors,windows,and fresh air intakes and in
accordance with local codes. I�
or C@ US Q I r
c�I
f� LISTED V
Note:CETL or CUL certification only appplies to unbundled units and units packagged
with limited circuit switches.Units paZged with the Smart Switch are ETL or UL
certified in the USA only.
FEATURES
O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:This
erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod-
Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI-
the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge
rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at-+1%.
O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small-
allows confident operation of sensitive electronic equipment and micro-chip based est electronic component
appliances,such as variable speed HVAC systems.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with
✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system
compatibility.
O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby
generators, Mobile Link Wi-F allows users to monitor generator status from any-
where in the world using a smartphone,tablet,or PC.Easily access information such
as the current operating status and maintenance alerts. Users can connect an
account to an authorized service dealer for fast,friendly,and proactive service.With
Mobile Link,users are taken care of before the next power outage.
GENERAC
�I �.
PROMISE ® � �0�
•nmrerun.tirsre.�p
GENERAC®
zMaNZIMEM
20/22/24 kW Features and Benefits
_ Engine
• Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly
rings help the engine run cooler,reducing oil consumption and resulting in longer engine life.
• "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance These features combine to assure smooth,quick starting every time.
• Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine
' life.Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown Prevents damage due to overheating.
Generator
• Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability.
• Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes.
• UL 2200 listed For your safety.
Transfer Switch(if applicable)
• Fully automatic Transfers vital electrical loads to the energized source of power.
• NEMA 3R Can be installed inside or outside for maximum flexibility.
• Integrated load management technology Capability to manage additional loads for efficient power management.
• Remote mounting Mounts near an existing distribution panel for simple,low-cost installation.
Evolution" Controls
• AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition.
• Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences.
• Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations.
• Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage.
• Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home.
• Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds.
• Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute.
• Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
• Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
• Main line circuit breaker Protects generator from overload.
• Electronic governor Maintains constant 60 Hz frequency.
Unit
♦ SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding
winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access
to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries.
• Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure.
GENERAC°
MIGIIIIIIIIINNOW
20/22/24 kW Features and Benefits
Installation System _
• 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
• Integral sediment trap Meets IFGC and NFPA 54 installation requirements.
Connectivity(Wi-Fi equipped models only)
• Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for '
complete peace of mind.
• Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
• Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due.
• Monthly report with previous month's activity Detailed monthly reports provide historical generator information.
• Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
• Weather information Provides detailed local ambient weather conditions for generator location.
GENERIC®
20/22/24 kW Specifications
Generator
Model G007038-1 G007042-2 G007038-3 G007042-3 G007209-0
G007039-1 G007043-2 G007039-3 G007043-3 G007210-1
(20 kW) (22 kW) (20 kW) (22 (24 kW)
-
;,^ Sri.,,t"�'}.�i�.'•..'Xu-;x:,ntrh"' .•,,.".;;:1.�.,�...3`u.,,,r�. ,S, z�.,,,ir.:'ri• ''g3:f.�:� 'M",':�i.Ss'�'..;,2 !;'S;::
Rated axi um:contmifaus' owerca ci I:P. '^:rr"':. r`y.'• 2b000•Watts. r„x'�,, 200DsWads„ ,126"b0O,Nlatts"', ,,;,.,22�00 'Wah's, „tr, ,24�OObWafts.
:�.,v",:.�.,'+dn...��-,.:,,:._,<•.,,-,.�:�;,,,f�„-,>,<t:,yr`<„•a7,�.��.::,.SMwu,S,rtS:JyS+:x:,u.J,:�u°5%F 'r..z,a��1,:::.N;.`r:.,,.r::t z->";'.,.:✓;,}ru,,v ir,�vAw,w<hK�':�.t,�''.� �`S``i. ,.�..U.45�,�1.:� w;i',,.,�.?3,,:_:?,',. .�nn�::.
Rated maximum continuous power capacity(NG) 18,000 Watts* 19,500 Wafts* 18,000 Wafts* 19,500 Watts* 21,000 Wafts'
77-YX .. wCwxK.t,,,,,w„�r.,.�.
rRat d•dfta a,,a:a<„i n.. a"f;,, „�i4ri MIN .,,s].,,Y, r ,is.s t:rr e„a:-" S QD ",.y.:S C L n n
�, t! � ,9.`L.X�.:+.....•�'rr :=��ik:ut�'L;�.i'..'ra.''S>„x'.s:,,,,'"..`fdJ_a_;,?._,x,.s`�..:<S.',�'"::n,,�: .,...:� ,v:^Mf,.,s`,�-.' '�:w�r�• ,<.. r:.h�z +1' 3 ,,.,v-�'_ r 44
+33.53`f.:�.h ,rxLiJ'+,`u,5 >tk.::. .b,...,..l..t .�:e.�a- .t,tat..,[ 3„rt?ni+i.{,WL.v'..S_1
Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 `w�83.3/75.0 91.7/81.3 100/87.5
1 1 �:c.'r�.:�:-"r':vx: .,.,,,s :-xM n"'M'.":,n" Nt"�'�"!'�f"_"?'3�"' ;�","r^z n.,::r�"'�`-,,,.. ,•„-'�^u,':x's«S'x-• ,,:r.:t#=�iH't.., ","` 'r,;'m;T;1"s;<?"'":'?,--"."..�._-:+--,rzs'r•ry::z,^+','--Sxra'c:;,'x'.l
iT tat? 2 `D'I ':`,>�5`�-•,.:'-5`,"-„k.?.j,.�'Tr n.t- �`;".sue'..` -n= r, ;,r,,, t„ '�".:�•" ,x:- _ ,.(,,
o H mioriic slbrtibn'':,:r�•; ,,,„;.,. :n"` x:x., �. •:�.; -,Y „,' :eLes'sthan5%' ,<�:=� .=x',
��......p�,a,.1:'_:•.,w.,....d._._..:id;;c°,>a`.','rr.rt:..•:.'.:.<.<,:i�s_r,,,.......-x.,-.-.,.._....._.sokv,..�. _,usaJd...,..,f::�k:`<?,.... .:.,�.�:i:.:.<,�.. .,._.>r::,:ai:_.its1'.a.+i�€ut'.;A::;v„,.a�'�z�eii>�'::"...:,,`v�_.,..1,..�
Main line circuit breaker 90 amp 100 amp_ -90 amp 100 amp 100 amp
'- -':'::(-,`-••"'- `.�.,..r=ar,�,-.r.-�.,�..._,.,,K_;....•.k,<-,c-t",--r":rt '-r`,:r=fs"-c - - - ^--n: -
',:t�.�t, - s. ,t'�.,'�' rn'�^r,c' ^>•�.:�`,," _ rN.lT r` -7'-�;r-'n-i�,-..�.m�n3 -mr,>+<-;;r�,m-r.::m;,-N-K,.�,s,
;a�'� ,.. %�`t'..,a._.�.,,�i.i:�k�'r�:...:`a: 'si,:�,..rx.,•..>_. .,.,>......w.4;:y...�;.:..,:,L',�..,..,a.'.t:K;t..-„--.�.a..::F";:�.:�z:;?.,-_.,,.!�".u;.::'a:t:�:aa,F,..,.,..:..,,....\",'ES�:z-v,.,..w-.,......s:.-.�..:,..i',ti3::s;;'r;.-.,-.�a>w:.r::l
Number of rotor poles _ 2
:.;y-,.. .�'•,�.- ._.�,,..�.�.o- ..,��„i„ fit.,,. .,.a^�?�'^_ ^'=LTgeF`-}'%M1;';T:' ^'rrr';._" ....'.':T,.T';x aYe"-="' .;'rev':�`_ a'f'+` "r5,"'_":'4r.'''r"""rT°.s"�3>,._=,,a :.:T'�--`..,,.,rm
{ �-,-;,,r--�,1 '.%t.. rt':'yi,.wY... �,.-„!;�. h': ':,r•r't,.,. f ].,
Rated`AC'fre ue rV':�`,y hs, �3..y,. Ic,..; �=`r..'a .r ,;a rl,:,'>r. kr,>„t�' ,) rir>r- 46D;�9T '.:✓.�;4,,s;r,r-.;r?:,,. ;•,L ,,: >;•.
4..,., .,q.,,*�✓,.,:+-a,1..v.,;4:M*Y.<r...:t: ::tx.:.�;naf�i:.�'+�s,�.clis�t::�'rnrr,..�,rx,•"a'-,.. -a`.`.�''�;kip"ti;.i;',Sz�..i2^.:i:`u'�Y;Sbw``"...:,;v.::ti::iz::::'f^,;t:;�'-..:x-4"�s�,.t':i}:Y_:�;:a,,.+:ea�w:at.r:.,{uo:.'.fwk�ir;.,...srt,�K'._.'y:,^.,a�3-.✓.a;�`.�,..'v,x!�:.et'�t,vd°
Power factor 1.0
--,e-,-,-,-R.x.-n•,:.,�,-.r-,~,r^•r„�-��,r-:-a�,.�:.r.:,.�,,-,..., -;:x�yn.rn'k;^^..,>,;e,.., ..,rwpxv;.pt-,,, �,,cw.-� r.:,'•^•5,•5^Y.r .-„v, _ .Gr._ _
( 5 .r..r .}•..•�qi .1 :s,'rlrr ;r.,:•s,f'.`=; `"r,y..r _ _ '•r.,: ';`r^.':;:it1".:Yf
8atie .re uue e s;Gro"u""'26R'.540`CCd"mi um_o�';Grou 35"�M 650rCCA m'inim'um
ry.x9-.m rr t,(natti)gcluded),.p :' � ,,.�.,-.�:`,"§'a»J.✓:r....`w.`:`�,...Gr::h�.a,'.:?.vi��.ti)„, .uu..ri'a'�1wS`2,u.w,x..:. P...,r�.
Unit weight(lb/kg) 448/203 466/211 a 436/198 x 445/202 455/206
Dr ensrons,LxWxH m,cm.. r s ,r:F .,. :.v' �4`z'251C:2 ,1 1'9z1i3:
Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load`" 67 67 67 67 67
," -',s,f:=,.imr�;t._...,F.,,a.�r:r•�',s.srr,'•'�`•�7.i3";�'; ;:f,r.,"r' .'tr.=F;,r�,;c?'"�^>-':s,�tf��:P..y,-.�.;,'t;L`!,, ;,1r';3i.�:'vJ
�Sobndaut utfm BA;at23'ft'7'm;wdh eneratorSm;Owe�Test"''low:s eed'exercise. ode'';�1„ Y'r:,.':�•, •�: ru°�r,'>•r':+':a =� �h :'�sl .t.. :67'.. ':,s'•
L..w _..s>S,..r.--...,..,�,..t.,3,.,..,�.u_:.,a,,.o.-.r»::w.,s....w.<„».e�sac,+.,.a..,.a.w.,,,.�.�rt„<.x:.su:x....,,::,�.,r.iJ:v.�wL:.Gr::?,,,s,,..,.+:t?,:;L-f�:�,t,,,J.::�::ia.u„<<,.a:4i�,:.,,c.>.,,;Yi:�?'.«,`�'.2i:sst'x➢,v''�.,+•'..,���s.:.a°.:i:•t::,.,,.s......a,w&.`a..m"s',,`.':a��:a�k.,,.',Y.;a''�^'�',ae..�
Exercise duration 5 min
Engine
Engine type GENERAC G-Force 1000 Series
P.'� _ -- _ r";S-'..Z-._'. _- -,Q-•4.. _ _ Y, _'c,^=:..4�':S' "PtT'^.�.- .i•^., ._n _ "'lTi'-M,. ,";'.1-,�, n'\_"s ^'riS•=':';',`T .:9 'SSlllr�'?• -+,',ST,-, -,-y;..,v �..'�Y,�,., rv?-�r,-rn G:,n".+,::i,'r'.•i �i,',f.l
- r� .:?.. .W.+fit.\ ':2a cti e ".).. -,("S>" .1:
cY, 'J n: t'1,..,-•.
4:,,,,_ ,..,,. „�,..,utLi:; ,,..:.�.,z�t:.,-A6ir,r.,...:-_���-„c:d,s:.,:,<s 1.S:1.rv...• ,5':i:�.` €ii+`:u`....-",..-aYF ;it.i'rti'1.x,Lx...�:.int1)s;�:ua.*e ni::;,",a�..,...-e Y,m.:c.�,.�s.'h;5m.<5iL>1:.=:.`.::,;iw•1.u1.c�,:r,>�:.,,x.. G::.�:d.a.....r....c-.,,...:.Si
Displacement 999 cc
- - - - w�.xs:-,,�rc>l,'�fn�ae r+yna,;,,,,-:,.,r,+..- '�y:;z:.< -r,�r.•:va,..•y.,,r;,.v .a'',l�r�;y-• rcr.-.,,;•<R^a, ._,.. ,,s?_ -,�:p ;,:,�.r:.,w- -
�.�,"`n<.:.
� inderbocktir. :r�x..-�z-;;�;� ,:A,>„s.` 1 '��': 4,,- „�s• �';� lu`num'w/�castsiroo'sieeve`, :"�,:,.
...1_. ...::�.., �s.ii.,.,.1....,.s:.a,,�'.:;:.:a.•��4_...,.�;;�:':.<.".s-:.�..st5S5•ca,..�,.,�._,_•.r�<...<.�.raw,s...,-::,,,:�.a�wfras....,c.'.�;s:r'.;:.,.1,u,rc:��.;,r.:tt:�°i£:`;•,r:�;..r<:...,..,. A m:,�, :,t..,,s,._. .., ..�..Y:,a�••.a t..+Lt4.'r`�'.,Y«%:wnL:�u+Y:�. ,4r:F'.i41•zs<_SL,b"3.::':.„:�
Valve arrangement _ Overhead valve
- -1'':e".,^ii „"Y/.i'+3; _ _ :1'"l r"tS-',:"' `f:7.Y,•::"^C:'.- �, n„ !,,r\n-r+-r^.^t';vi h.-+`+rrT"-
P�r <p. .i>7s!.;., ;.G.. fl "1 a mot. is=.`
d oh tern., ':�, .< ;J_ '.�, ;` �, •::�.� ]t 35olid`sfate�vr riia
..._:,6.'3..�. ::,' - ;'iGI...,
Governor system Electronic _
- �rry'r*.^r -s�,, ,..r.; ;,.�q.., ;.�,•rnr,s�a'�. �r,. ,.-s .*=:a*^'.rsnr.a_a•;^.:,rr. a,. - ..�,. .,.-,r<n -�-?,- .�-„n:..�-,.xv-
':�
!, )'', .•tiN: .AS m''r1 �f�:p:;'.tl ('1'vfi: l ,rzr:':rl,.+ .p. y,; �t.:�5u+,�, .'F':n"";,,f ..4 H
t Orii e5S n�ra ars "� r.;;'E ^,5.1�;, ns ,,,, ,s• ra. ,rt...,"_;'.., :9.5:fr,' • �r' r;:. ,•�
,.P"., .�.,._.,v,...��w..dzia._,kc,,..:a:;:r..,.-s3i:z` '•"Si;�.'e�tL'sYxN�f:;r,�,<f;'.'ia.E;3:l ':';.its;�.,.,,.iiai,.....,,,..,.,.:'r�.�t'.'',�''`..w,ti�%2iu.)..,{.1'.:rk:;5l,�iY:nrrP.�.,,.,...i9:+'c:.,.�v;,,'..(#sa,ar-_`,,La., u;1.!^',�,:,.....5::]:::;lA'a�fi:1>dC6.>•_,,._�.i",rh't3F.SN'�.�snsfSt:.2txr`�:Cz4„aa
Starter r 12 VDC
- "�:L1"Y,i �`.r.r ..,Y,.. •ln ay;.�,,:�r.,, ^(•rv^., ,>FF,:u, <ly,J--'e...,-.;,+"',; ,i:t,<v,,,;.;,.-.:��, v ,., iYL,.N„-u r a. ,,�'•. t;a :'Yi �i ""-,;,i:, t;� i
� d ca act ncludm hl en,:, ,�.< .::�,• c•
. x.,.-�__ ,rt,,,�, $d.,cw,st.,u. .Ic.. 's.„.::; ...y.:,� 1?,riz,.,..G,..,,.,,,,,, vr,;w'Yh);5<.,.,y..,,t,•,:,,,,is;�::::.«.,z..rv.,,-,.� r9„ ,,arv:..w.,,..,...r..G.>W,_n„_,.":r:«:,,.,..r.s,.Li;v ,..�.,.,' r�,� ..s'.•�uti-.irx,r:..,.s.»,.: ,. y, '':.. ,.•rt'i .velww �k'l+H.ti S:.}ku.„'t'
Operating rpm 3,600
P ,i�a �-�t'i c'J'�.4,• "L:'.�;:� � X ., -i ,t:z)r�:'s;�,ti�^,.�,'r? t,- ,y,y.,r 3;1,'. `F,< .�4r- «•i".•r:� >%,4
`r, 9a `Natural, s .,� - - -x"+ 3• 3 "ct:,t'3`i -� ,t„ ,x•., ,(, e - .- _ -�tai%i ;•,•.>°r ;'_ ,_ _.4''
.r�e" �?r� u'�•i�,. tf/hf;(rn/flt)Yd c r c-S';�', ,'N:,+;s"�=1•r>.,,"`,.:,,� .s ->•, '.r, .5. � <`t,`.,3
S' .',S,`
2 5.78 228 6.46• ��-1• ,4n64 03: 7
2 „
,•t?: •�t3:F'�?r" ,r. -.� 'yri;:»� ,? ..`. •,i(-;v.;.r.r".i;:Y :`•�.,3 �,.,..'z',;,,
r.),":_ t:r:, - ">,�,. ,,.- _x ;tar:.. ,,r•.. ,.:.:.,H'',,:=.r:,,
'3 t
.b.Y -
tLi"aid•�jo' ite-� ;:( ,ft �-" al%fir''•Ulir x ::�`` ,..:�:� �._><
�;1` ;L"oad}' .'� ,, (2 ) ]:;r ( .),[. 71 s8 (2 6)':8.9 •.92;(2 3.9.5.
f s; .:t
S
i'Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP
gas.For BTU content,multiply fts/hrx 2500(LP)or fts/hr x 1000(NG).Far Megajoule content,multiply m3/hrx 93.15(LP)or m'/hrx 37.26(NG).
Controls
Two-line plain text multilingual LCD Simple user interface for ease of operation.
fMo es' u r � _1 :tlt„-M,c sa•ems ires:d "' ;.,�^g,' tyailiire`�`1f3eel'm{ e�rj,".,"r,•,,-i Mo i"seleca r<..
MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place.
^'n.,:,. ....ro-ry.,_.-..,,y, v^lye"vr..:..r-.... n..�.r.�r;N'tn` '^,;'4• „.r-E,ar - '.^Ptc[ rr.\": n'e6,•. _
.'t. ,t,�,•'.(. ,� .:'4'. .,,_.v�C�k�!3r.'4. :xr.: .�:."•{[,n:r.'`?,f4'",'*':"'.`"1�i'R:,. X%; ,i+�`- rr;�e7 ,4,. r.,5o,; .,.y..3,'"es' ,:6.'Pq..^^",.Y,r,,^'
� c• -.s :d•: 'its'p "`at..
wx•'. 0 "�,- :,- t�" -�Sorr'`"nit`:F we°'i re or'�'d� o�"o a h r'"r�il.`o'e'M �z�r.-' 'i.,w ,I:'• ::.T�,,=<"(-•rt. :�•t(,,:, k v„x,. :>« .1'. '>�'�ys .
Ready to Run/Maintenance messages Standard
n.�v.- - �gm..,�. '!!�'r�d]'.' ,r (]➢.•:i:zl'S:""r,�•>" -,•qe•,-Txr- •--K'�: •::>";-r ^':-, :,-•r.,. +e:�„"'''�.-x�;,.,•,:,s•,.
[Eri ine ru'ri h'ou'rs ihdicat'on rsn
r -3' m*�'Y.'� .1�r'. ','L';• ''j,: <:'1' -�::;�.>Stantlazd,'> �,,�,.,;:,,
-,„,a.,.., .,,tiAa"i,u ..2Ys�:_3,.o.c..,..e�i'i'ie..,,,».rr...�>•rr�.:>.,'sA2Y:i`i:.],.�::,o-..',n..i.w,,..:;.s,.r:�d=:`>nc:cC4f'Li1.,:.."`.-.-,.ea:.e;,.,,�k,`'..-...L:�'.'_':,�;:,,,n,:ss,._,....,,.:..:.'J.�s..c,1`Crl".:t.;.sdili...,_.K..,�.:z»"i:a�:.tia�.k:%H:a:.a.1'.at<;�s�,*1
Programmable start delay between 2-1500 seconds Standard(programmable by dealer only)
(,-•:-^"+�-'^.--•-:n-'- x,�r^` .:,z'.r-•-�--s;utr. - ,.-..�.. .-,;;fir-^T,�;':';;r,.,;'-;�'rt- -"-r,-- -
f:;.:ly'q,:. �,Lv�r.+•::�+_-�tr,,`"y.?' "'.'�,.:'` .,., x`.�4 �rar's' ''��r'�-5.';r'�'%��"-;,nz�,,�v",t
,Uhift ,Volta a Loss/Retum.tarUhh ad astable,brownout set[iri� :,;j,: �..�t<:,, ,t.,,;Y-,;,,>;,',;,.:c]: ";:-v rom:1,40=171;:V_d.190=216 V�� r r'rrf::.:G,.-,,, •�j =a
„y„-„9,,,,. �,..._..�a..a�';,�1-.. :,,�.•.(,� .�,..,9).>±zl,..,...k`.'sz:]��-ate�v,_u.,,M:;.,�:•:m1;���`�t..,.,,.w:�_.u.:.',.,<:ic:,z�s:ii�rY.�: '�-;.�...._,.�,�...� r,..,_,..uu�.�o�,r�_.,,.c�.�
Future Set Capable Exerciser/Exercise Set Error warning Standard u
- - -?�'��:;r.:,rys",fi4 fl:":i:..,,-,.l+,n•.:EKa:,.)N',rt;'wl;c�-:uyt..,;,.rvv�,u.nTFv,�.�-;n,,.>-,,",.-n l�rz-„_,,,x:m5.:tx,_,;wc`".r'--'!'.`:^r+':^r ,_L.,p.,,ti3`I m�:S^3.'riK ^vn�m
iRuNAlarmlMainteriance'id s1 - ,. - tF,,z:_ _ •,:a:' _r; K, ;.�` ,ar:,4^ __ ,50 ev'ents'each. ,Est:�:,,�; ,,
Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration).
- - �?i;",_�-`rC"^, ^':W.`.' ,r,^4r - fe-'a»,-,�,.L:-, <'t^.z,`isa „rt,,.- __.,z,.,,-, - �^.-*ter^-,•'.•-,•<m,r�- ...;,,s_...r_
7' '.,L, viz.:t ";f%<'`":(-, r;A:' ,.i'�ai°,'-''�;;7`..X .l.tc- .,r,•;'si��Pt, Y., .�'v.�, "t "`�;, „5
,Staiter�lock-ouY• �,_. .',•• <. ,,. �'Sia er cab obTe-eii""e uritil 'sec after en rhe'as`o}ed: T';y a., w•'�,� ;::�.-��'r,, . : y;'t,�;• ..?° .*,•� � •rk i�J'�. .['+,,n .It _s. f! 9a9.� .9. .h .PP,Smart Battery Charger Standard
•,}Y:� ;'1•".=,1 .t; .^'Tj",: t^Y'r`yrp^ P'">.'r"n,-:1,t"'m;✓,:ve rayy^^l"ri�"'�: ^,?:L'., ,";1'tY'.' _rl^n+v •rr-ck^!cal`drTp ;^T"�p^,%C�A:,,"vn. ^i^,_,^^rc.e
vfa?xx"r ,:V f• sot• ,{; :,� r.r5„ ,'F' .✓i+, "i'"e, 1-, ni,w, <r- •,"'ems'"✓•-,i•; `li"• ,r,t.. ',r .:n""''Ev.,-.�'r,:..ii
C ar erFaul issm A wiz m ,;,. ,,,: :;- , n.,.,,,,.•Y .. ,?'. ,,.>,-. �r.,: ,,�..
S. h VM D. �.`4 ;�vi. ,¢. r.:�,;,c..>, c:J4•',,;.n'.,.:k.•.1••,t:.d..v„ $l'dndar�' A'�',+5', ,.,.,...w.,s<, ,.s
_r.4.,,�:,,.%�:::;�'+<,:,>3;3.�_.Tat,..ra:.f,:.,.,,s.;,ra,i':'b'�i:.,._;�,.,1�,:~ix;�'��..,,iss::�:,c'ci't';:a.:,•t,�,,+r<;�:5:,!.�,J:,,,,,;;a:;,l,:::*��:..,.r...,_.,,,.�,'�..:.....:......::.::.•.:.,,,,.,:�^...;�.,v:cwd.,;d,._,..��:.,.z....H,•;:.r`:.,.,,�s.c:lrx
Low Baftery(Baltery Problem Protection and Battery Condition indication Standard
r•^�:r - 9�, <.�,e _ ...,,,. .,„,�•, '^",r.-„-,r, ,..n.: ,.,,, '-(., ,•,�R,-;�--� •ter -�-r��:�5-•.•;,, ,,,
t l,.A,,uJaapt - .ir-17. {.^i„�'�'?'•,"��h°=:',l-;:'•�: e:.S^" �"'1:", .5,. �r,4'�✓ :.-�.• ,rc,<vr". +f';':
3, "`jd:s'f�n �,�.D^SY,,rv:, .Z-".h, vy.. •�t'>rx'! '"J:`Ys, .,S
tt is"Vdlta'�R ula` r> ;,r rw• '+�s' ,,.
Atomtit a e' tionwift"•'errand'.UndecVolta'e,Peteciidn. .�.',: ',� ,H.. �.,r�.' =,JS,•.r;a a"d�d•', ,,,'
Under-Frequency/Overload/Stepper Overcurrent Protection Standard
_ „.-,.. ,�„,�„ :.•�,... t ,�� ti:. Apr„
t ,,re, -�;;` sue, t;a„ ;.{ ,,,�,:;• �. •�e_r,,
'Safeue u'se' "b P 's' ��`� .,. �� a,:•.5+„. ,_...
6�'F s d/F Pra tern .rote hon :�•'',,, mr)�: �.�'� , Standar �-sl+ ,���`'-;:-• ,�•�"
Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard
•'e>v`l' :'<'p"?is ,:7ry ^f ry,-r��Cgcs V"ia�+SiT.?-.; j,q),'..(:.^;'a F,s,.y,.-,�,nfW(e,r yrj 0.^,.,,+,n^;,- w•1., ..�,�,-.,�..,,;.«. _.yy^.s
0veicrari Overs eed; :7Z,Hi mSense:LossShutdown" :'? =�:,°m.��, .>".• �: >f�' �.�- a'"ar .r•." �>"%.� ,n�r,�""
,..:....rv,...... ... .<....1,.:., _ 9.,n:.+..,«.a,w_,«.x.<ru.,,,. v.,.u,f.,a„-u,..h.:�a'a._J.,.._.,ua..,_.nsw.r.:1,3:a_...,.::Y.'.u'1k.n..ntl.i:.hL::,,s.ai11.`,�ir�'s':��."��sf✓2.:�.,..,.s.�...:�, ,...a'dtz�,a'.%"iv:�_',o•.,s..-�.�.:,..�:,--._...z,:<...�.wns,._'.,,r.Sl,�-,__�1
High Engine Temperature Shutdown Standard
__ - 9�F..ni�r- - v��y;-+rv^�;:_-.S]?.-+^r:e�,��., m'S�ut^�' r.�Y,'i`-..�"2,.'4i' ,.`^tT5"rhUl�;r�t:` ".":C'.' �.:7r;nr-•r-an
Intemal`Faul ricorrect trio_ Totedib .�:+:" .5: •==."__- -(,to _ n�.;- r` ';��"• "=x~< ,�i, .;ct .Standaidr�'-.
Common external fault capability Standard
- `T:�'i✓e�'','"• Y'""z]„n :'.-°�"e�!r.,•c%C_�., ,.,,,,,e^r.�:f n���a's:,•,: ^r, ,rrrr,:-"^,'.,^��:^'s;�••,^7�,-^,:.�rxs'^ -,«""�".�•.r:,. �;T c^+i
'S-s, � i''�-:Ltr ,',r,��m- �'�f'.,r.:t;'T,;s"s�„b - ,;C.. (3"':i: 'z`k i- �-n c3.. 5,. ;,��7".';•;,t- r,rr,,,s`;.s, ?,,,.:.'.
Field•ii' iadabfefirriiware....r�--:,•, ,.>,,: ,.a, �, s�•, r'S...r: ;r.5., ,:�_,. M:Slandard. r,,.,. s. ,-,<., ,�f:•,;;�;:.> .,r,.
�,,..,-.,.P9,. »,w:H,,,_.....z`nsi:�-�.c.�i:uc#:...w�,�:+..;_, n.Si�.;(e:,. .nb.z�t'so",3-tk:,'.,a:stsYe�.r; %fit:SL`+<�=.vi;:�'1i:i!e,_i,:.Sins„ .,,:ai.`�3er;�: ,.:.xvr;i2.,.r <�.?.tir_.S.cr.,,:r,::kV.�P:.:<., i'a&�,viz.::�,.u-v,�„•b;y:;�.,.�i:°..�_C.:!
"Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying
emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271)."Maximum kilovolt amps and current are
subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 it(304.8 m)above sea
level;and also will decrease approximately 1%for each 10 OF(6°C)above 60 OF(16°C).
- GENERAC®
20/22/24 kW Switch Options
Service Rated Automatic Transfer Switch Features G007039-1,G007039-3(20 kW)
• Intelligently manages up to four air conditioner loads with no additional hardware. Model 0007043-2,G007043-3(22 kW) _
G007210-1(24 kW)
• Up to eight additional large(240 VAC)loads can be managed when used in conjunction "7, 7 " "` """
9 J NoNo of'poles ;'u..,, c,-- -,,.,,.< 2;•,
with Smart Management Modules(SMMs). " 1
Current rating(amps)� � 200
• Electrically operated,mechanically-held contacts for fast,clean connections. Voltage rating(UACji,.,
• Main breakers are rated for 80%continuous load. Utility voltage monitor(Fixed)`
-Pick-up 80%
• 2-pole,250 VAC contactors. -Dropout 65%
-"--;-�:r-, ,,—......-.......;,.n-�.
• Service equipment rated,dual coil design. Return tn:Utiifty'.I;� �:��Y�!rM Apprpw 13,secr
ErL or UL listed Standard
• Rated for both aluminum and copper conductors.
tE9closrire:typ�e_, .;s•; ;.hi ��'.,;,� :'s�P:',;.�,'NENIANL`3H': 'i,.:,4„r:�
• Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000
Lu'ranrn'"ne,�v'-,�.�,�:-�;�'��:•�,�`,..t:'-`,•�r'.;"'250.MCM�#6``.t,;;;h'���R�`f
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mountingflexibility. w'"``'
"Function of Evolution controller
Dimensions Exercise can be set to weekly,bi-weekly,or monthly
W,
200 Amps 1201240,10
Open Tlansition Service Rated
Height Width ,
H1 H2 W1 W2 Oepthi',
in 26.8 30.1 10.5 13.5 6.9
cm 67.95 76.43 26.67 34.18 17.5
H,
Wire Ranges
Conductor Lug Neutral Lug Ground Lug
250 MGM-#6 350 MGM-#6 210-#14
..nrrrH I--W2—I
GENERAL®
MMOMMUM
20/22/24 kW Available Accessories
F 3� 71--P Descri iw�o
G0071 01-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(-18*C).(Not nec-
essary for use with AGM-style batteries).
�i warmer slips_directly over the oil fitter.Recommended i-- f for use ifi temperature regularly I—ady falls beIow
G007103-1 Breather Warmer I§r7Wtke-r warmer is use'7,n-Txtrem-e—cold weathapplications.For use with Evolution c'-on-trol-leirsonly in clli;_aiis�h where
1heavy icing occurs.
G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may_not_b_e1
Contact Kit needed.Not compatible with 50 amp pre-wired switches.
Base Wrap Kit base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,con
G007027-0-Bisque Fascia_--_-T1iie-fa_i_ci i---- --t-ou-re-d1l
JS!ndard on 22/24 k" lappearance as well as offering protection from rodents and insects by covering the lifting holes located in the base.
e generator enclosure is scratched or damaged it is important to touch up the paint to protect from future c
tGO05703-0-Bisque (Touch-Up Paint Kit f , 6-r-ro-sio-ril,
I iThe touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
rG0_0R8_5-5_"Scheduled FaTcWTF Generic's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a
Generac automate standby generator(oil not included).
60-07-065-0--
Wit Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides co .Monitoring th constant monitoring of the connected LP fuel tank.i
!Monitor iLP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta-
tus alerts are available through a free application to notify users when the LP tank is in need of a refill.
Lff7-6-00—amp) Smart Management Module(Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages ligeeTeG_-
IG007006-0 fical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce
(100 amp) e overall size and cost of the system.
The Mobile Link family of ZeIRfair Accessories—allow users to mon-ftor'generator'status from anywhere inin the-wo"d-d—,using-4
i
G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us-!
i I i
Ethernet Iers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link I
(users are taken care of before the next power outage.
IG007220-0-Bisque Base Plug Kit 113ase plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers ak,contoured
appearance,as well as offers protection from rodents and insects by covering the lifting holes located in Die base.Kit
(contains four plugs,sufficient for use on a single air-cooled home standby generator.
Dimensions & PCs
Model UPC 637,0.. 121a I
G007038-1 696471074185 12&1 In] 148.0 In]
G007038-3 696471074185
0
G007039-1 696471074192
G007039-3 696471074192
G007042-2 696471074208 727.2—
W.0 In]
G007042-3 696471074208
G007043-2 696471074215
G007043-3 696471074215 o -4 0 0
G007209-0 696471071511
G007210-1 696471084801 1 1 164826.6 In] 1 M. 123248.6—
Irg
LEFT SIDE VIEW FRONT VIEW
Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
GENERAC® Generac Power Systems,Inc. - S45 W29290 HWY.59,Waukesha,WI 53189 - generac.com
WOMEWHERM @2021 Generac:Power Systems,Inc.All rights reserved.All specilications,are subject to change without notice.Part No.A0000937814 Rev.D 04/1412021