HomeMy WebLinkAbout50913-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE g SOUTHOLD, NY ' BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50913 Date: 7/9/2024 Permission is hereby granted to: Clark, William 595 Kerwin Blvd Green port, NY 11944 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. At premises located at: 595 Kerwin Blvd Green port SCTM # 473889 Sec/Block/Lot# 53.-3-17.4 Pursuant to application dated 5/14/2024 and approved by the Building Inspector. To expire on 1/8/2026. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-RESIDENTIAL $100.00 Total: $325.00 Building Inspector TOWN OF SOUTHOLD -BUILDING DEPARTMENT l� Town Hall Annex 54375 Main Road P. ®. Box 1179 Southold. NY 1 1 97 1-0959 Telephone (631) 765-1802 Fax (631) 765-9502 hr.t r Date Received i APPLICA riON FOR BUILDING PER111MIT For Office Use Only PERMIT NO. SaQ//3 Building Iruspecton r Applications and forms must be filled out in their entirety.Incomplete I a applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. F Date: OWNER(S)OF PROPERTY: Name:6C' D- -4 CAGt.r)(- =TM# 1000- Project Address: Phone#: G,3 - 2 - -7 o Lf I Email: Mailing Address; , ' � S tin $l v��,�. r�-�. � IJLls CONTACT PERSON: Name: L O Irlr A,! n CMailing Address: -747O S0Lod VY2 �'}/��.�-4-D L61cJ Phone#: (D 23 1 3 9 2 �'7 0 q I Email- Pero+S DESIGN PROFESSIONAL INFORMATION: ATION Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: eloo V o � °�l/g� ♦�`f n 0 Phone#: � . �g (� ''� D 7 � Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ther I nb+-L,0 �,So )ar PV S I �0 a. !;), Will the lot be re-graded? ❑YesANo Will excess fill be removed from premises? ❑Yes to 1 PROPERTY INFORMATION Existing use of property: kc,4_ Intended use of property: )QU Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? s El No IF YES, PROVIDE A COPY. 3 Box After Readiing: The owner/contractorldesign professional Is responsible for all drainage and storm water issues as prmiifed''by �4tele;C,6of the Town Code,APPLICATION IS HEREBY MAOE to the Building,nepartment for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Lorraine DI Penta WAuthorized Agent El Owner Signature of Applicant: � ( � � � Date: t"""I � STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Lorraine DlPenta being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this H day of 20 1A Not Public PROPERTY OWNER (Z I DEBRA A SEPULVEDA OTARY PUBLIC,STATE OF NEW YORK (Where the applicant is not the o ner) Registration No.OISE6012697 Qualified in Suff,'lk CoU t Y My Commission tpi'N,S " 00 IIS Co 4-+ CIC-III IC- residing at's 9 S ►n I v� 19 11 4L1y do hereby authorize Lkf"&4 0 Aun ,leM A, - to apply on Encjw L_c__L my be f to the T wwn of outhold Building Department for approval as described herein. Owner's Signature DEBRA Date r irk A SEPULVEDA v C NOTARY PUBLIC,STATE OF NEW YOM Print Owner's Name Registration No.0 1 SE6012697 , Qualified in S lk 0o My Commission Expires ZZ � .. F UILDING D EPARTMENT- Electrical Inspector W .,' TOWN OF SOUTHOLD r' Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 &, � Telephone (631) 765-1 a02 - FAX (631) 765-9502 " mm , ro, err southoldtownn o - seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 5 Ilaki Company Name: 61eMC414 Er) L_L_C> Electrician's Name:J&,i m M jl y)n l K ° License No.: a, °� _ t Elec. email: Pew-rn o+5 e S �S. e_&Aq ��� Elec. Phone No: .-' 013 [9I request an email copy of Certificate of Compliance Elec. Address.: 7 `I7 0 00ft, fn A-4-1n`4�cV_ l l JOB SITE INFORMATION (All Information Required) Name: U co Clcrw:.r Address: q,S K-f,-rW)_n 61Vr r - 11qqq Cross Street: 'n k Phone No.: c3 1 > $ • `7 D Lt i BIdg.Permit #: email: P�rM I LO " Tax Map District: 1000 Section: OS 5, 0,%D Block: O a . 0 b Lot: 01 q. 001 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): sn s-�- ►us h i2.�o F ►-ri �.�►ti�-c�. 010�� P ✓ �S Js4t to Square Footage: Circle All That Apply: Is job ready for inspection?: YES N NO FI Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size1 Ph[:]3 Ph Size: A # Meters Old Meter# ❑New Service[:]Fire Reconnect[:]Flood Reconnect[:]Service Reconnect[:]Underground[-]Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION �� l workers'�t Compensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS d _.... �_ .............._ ..._... ..W.�...w...................... disability and Paid Family Leave benefits carrier or licensed insurance agent of that�carrie 1a.Legal Name$Address of Insured(use street address only) 1 b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 I 1 c.Federal Employer Identification Number of Insured Work iocatior,Of Insured(dfilyrequired ifcaverage is specrRtallylimited ro or Social Security Number cerfain 1ccations in New York State,i.e.,Wrap-Up Poky) 823336604 ............ 2.Name and Address of Entity Requesting Proof of Coverage 3a_Name of Insurance Carrier ....... 9 (Entity Being Listed as the Certificate Holder) Shelterpoint Life hfsurance Company 6 TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box'Ia" SOUTHOLD,NY 11971 DBL567527 3c.Policy effective period 01101/2023 to 12131/2024 4. Policy provides the following benefits: ® A-Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefrts only. 5. Policy covers: ® A.All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employers employees: Under penalty of perluty„1 certify 1lroat I am an autiaorrrrsd repro seniatrve or li agent of the insurance cagier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7110I2023 By lSignature of insurance carrier's authorized representative or NY5 Licensed Insurance Agent of that insurance carrier) Telephone Number 51t5-8 9- 1 Name and Title Richard Waite Chief Exec love Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 6200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only If Box 46,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 or the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Beard Employee,' Telephone Number Name and Title Please Note:Onl insurance carriers licensed to write NYS disability and aid family leave benefits insurance orcies and NYS licensed_ ....�_..-..a Y ty p y p insurance agents of those insurance carvers are authorized to issue Form DB-120.1 Insurance brokers are NOT authorized to issue this form. D8-120.1 (12-21) � �� ��N1I�BIII� III�li�11111� 11 ( CERTIFICATE OF LIABILITY INSURANCE °ATE'MM7/'°�0�3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the Certificate holder is an ADDITIONAL INSURED,t1w policy(les)must have ADDITIONAL INSURED provisions or be endorsed!, If SUBROGATION IS WAIVED,subject to the terns and conditions of the policy,certain policies may require an endorsement. A statement on this Certificate does not confer rI hts to the certificate holder in lieu of such endorse s... PRODUCER NAM ROBERT S. FEDE INSURANCE AGENCY PHONE - - IAM23 GREEN STREET,SUITE 102 No; L HUNTINGTON,NY 11743 ADORES ...,........... ............. ROBERTS-FEDE INSURANCE tNSURERI8)AFFORDwO COVERAGE NAIL If INSURER A;ATLANTIC CASUALTY INS.CO. 524210 INSURED INSURER B. Element Energy LLC alsuRER c DBA ELEMENT ENERGY SYSTEMS fTT AlSI1RER D 7470 SOUND AVENUE MATTITUCIC, NY 11952 INSURER EINSURERF: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER, THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WTH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIIMS. TYPE OF INSURANCE LTR ...•_.. POLICY NUMBER. !D LIKI COMMERCIAL GENERAL LABILrrY L14500361173 EACH OCCURRENCE S 3,000,000 A X X 7I14/2023I 7/14l2024 CLAIMS-1AADE � OCCUR PR:EMISESL"0=* • $ 100.000 MED EXP IAn are n) S 5000 X...... C1*., l Ua PdA389203B 7/1912022 7/19/2024 PERSONAL d AOV INUIURY S 3000000 GEN'L AGGREGATE LIMIT APPLIES PER ` GENERAL AGGREGATE $ 3,000,000 "". JEC POLICY a PRO PRO LOC PRODUCTS-COMPlOPAGG $ 300t]Q AUTOMOBILE LMBkITY XABCN s ANY AUTO BODILY INJURY(Per 1)8=17) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per sodded) $..... HIRED NON-OWNED PRCPE'RTYDAMAGE $ .. AUTOS ONLY AUTOS ONLY UMBRELLA LIAB OCCUR '...... EACH OCCURRENCE $ EXCESS LAB CLAWS-MAC AGGREGATE S OED RETENTION $ WoRUERSCOMPENSAmN 124494445 PER AND EMPLOYERS'LABILITY YIN A tR ANY PROPRIETORMARTN€RIFXECUTIvE 7/132023 7/13/2024 $ ..E B OFM �MUE EXCLUDED? N!A EL_�cHACCIDENT 1000000 If yes,decor-be wider EL DISEASE-FA EMPLOYEE $ DESCRIPTION OF OPERATIONS baky. EL.DISEASE-POLICY LIMIT $ NY State DBL DBL567527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS I VEMCLES(ACORD 101,Additional Remarks Scbedwe,grey be alteebw H slave spot is regWrad) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certticate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted Operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE:.HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORaft REPRESENTATIVE RaZewtS. Fed,-, ©1933-2015 ACORD CORPORATION. All rights reserved. AI-non>t l3n4Glnti TI— Arrneon.,.. --A 1--- ,:ve .,—4— s Armor, YS F New York State Insurance Fund PO Box 6W99,Albany.NY 122C6 1 nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) ^^"^A^ 8233366C4 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11871 MATTITUCK NY 11952 IL POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07/1312023 TO 07/1312024 7N 1/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT H I I :IJWWW.NYSIF.CONVCERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY_ THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION ANIVOR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STT U NICE FUND 4 �/ 01RFq;T0 jNSURANCE FUND UNDERWRITING Page 1 of 2 Current 05/08/2024 Renewables Element Energy LLC Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Scott Clark Residence Project Address: 595 Kerwin Boulevard, Greenport, NY, 11944 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 �V1. NEW yo oO�Rt A. I4 , Current Renewables Engineering Inc. * �' Professional Engineer c1c info@currentrenewableseng.com ti 106793 -e _ p F NPR Signed on:05/08/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2of2 Summaries: Check 1: Shingle roofing supported by 2x8 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 16 degrees and has a max beam span of 15.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com ROOF MOUNT SOLAR PERMIT PACKAGE SCOTT CLARK = �I f t 4 2024 6.800 KW DC GRID TIED PHOTOVOLTAIC SYSTEM :4 MAY 1 595 KERWIN BLVD., GREENPORT, NY 11944 �F,�t''' AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES: THESE DRAWINGS ARE SUBJECT COPYRIGHT PROTECTION BY Us LAW. THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY REPRODUCTION IN ANY FORM IS (----- ---.. I POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: SOLAR PHOTOVOLTAIC INSTALLATION• EXPRESSLY FORBIDDEN WITHOUT PRIOR I 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES WRITTEN APPROVAL FROM CURRENT ? 2020 NEW YORK STATE BUILDING CODE RENEWABLES ENGINEERING INC. s 2020 NEW YORK STATE RESIDENTIAL CODE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED- 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE 2020 NEW YORK STATE MECHANICAL CODE UNDERSIGNED i Current 2017 NATIONAL ELECTRICAL CODE(NEC) 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 �! 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT Renewab¢4 es I SUCH AS GeoCel 2300 CLEAR SEALANT Engineering 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL I JURISDICTION AND THE UTILITY IS OBTAINED CURRENT RENEWABLES 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, ENGINEERING INC. MECHANICAL,OR BUILDING ROOF VENTS 1760 CHICAGO AVE SUITE i 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS J-13,RIVERSIDE CA 92507 AHJ:Village of Greenport THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE • ? - PHONE(951}405-1733 LEGEND 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED WWWcRP NG.CO CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S CONTRACTOR INFO INSTALLATION INSTRUCTIONS"- I 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS uM UTILITY METER PM PRODUCTION METER 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6' { MSP MAIN SERVICE PANEL INV INVERTER 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC.• 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY C�SYS BUILDING INFORMATION ❑ © GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35. C COMBINER UB SUB PANEL 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.- ❑ MODULE LP BACKUP LOAD PANEL 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE ELEMENT ENERGY LLC. 1STORY HOUSE SINGLE FAMILY RESIDENCE NEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF 7470 SOUND AVENUE,MATTITUCK, Q ROOF OBSTRUCTIONS REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY.• NEW YORK,11952 KI(2 IQ CONTROLLER 2 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 718" PH:(631)779 7993 CONSTRUCTION TYPE: V-B OCCUPANCY: R3/U 36"ACCESS PATHWAYS ABOVE ROOF SURFACE. services@e2sys.com HBATTERY 19• IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE Licence-ME-52689 AP N : ® 18-ACCESS PATHWAYS ❑ RATED FOR EXPOSURE;TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS.WITHIN (MASTER TER ELECTRICIAN) EC RICI N) QH Q.HOME HUB ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 1213 CONDUCTORS THROUGH (SUFFOLK HOME IMPROVEMENT) 1000053000300010000 ROOF ACCESS POINT OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT RAIL AC ESS DISCONNECT 20. MATERIALS,EQUIPMENTAND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, SCOTT CLARK SHEET INDEX ❑ STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO RAFTER LC LOAD CENTER THE PURPOSE INTENDED: 595 KERWIN BLVD, ATTACHMENT GREENPORT,NY 11944 PV-1.0 COVER PAGE E::] SEPTIC TANK PVSUMMARY MBE MAIN BREAKER SYSTEM SIZE PV-2.0 SITE PLAN ❑ ENCLOSURE SSS LEACH LINES LOT SIZE:-0.83 Acres (KWDC) STC 425 x 16 =6.800 PTC 398.1 X 16 =6.370 PV-2.1 ROOF PLAN TS AUTOMATIC TRANSFER PROPANE TANK SYSTEM SIZE PV-3.0 STRUCTURAL SWITCH (KWAC) : 5.1]A WELL INKOSOLAR PV-4.0 ELECTRICAL 3LD © PERMANENT ANCHOR WIND SPEED 128 MODULES 76 JJKM425M425N-5454HL4-B Z POWER LINES SNOW LOAD 25 MICRO-INV.QTY : 16 1 ELECTRICAL SLD c0 NE MICRO ENPHASE IQSMC-72-M-US PV-4. OT TEMPORARY ANCHOR NO LADDER ACCESS EXPOSURE CATEGORY C 4 ��. INVERTER PV-4.2 ELECTRICAL PHOTOS 0 (STEEP GRADE �P RT A. O,p UTILITY (0 G ISLAND POWER AUTHORITY IL INSTALLER LADDER OR GROUND LEVEL *��0e� �4 PV-5.0 BOM OBSTRUCTIONS) PV-6.0 SIGNAGE $PLACARD STUB-OUT O GAS SHUT OFF r Rev Description Dale PV-7.0 SPECS+ ® SKYLIGHT H2O n A INITIAL DESIGN 5/82024 WATER SHUT OFF n_❑ 2 106793 �� PROJECT# B858 RESTRICTED ACCESS O7 SERVICE DROP �0,0 ��' CONDUIT �C AC DISCONNECT SSIONP DAWNATE BY E.R5/ DRAWN BY FJUNCTION BOX Exp:9/30/2025 SHEET# Pv-1.0 B STAMPED 05/08/2024 TITLE COVER PAGE R324.6.1 PATHWAYS: WIND SPEED : 128 LEGEND NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON SEPARATE ROOF PLANES, SNOW LOAD 25 FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS.BUILDINGS. EXPOSURE CATEGORY C AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR qq� -�--�- I UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. 121 FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM -/--� i MSP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE -�- i COMBINER OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS -�- ACCESSING THE ROORPATHWAYS SHALL BE LOCATED IN AREAS -/--�- ❑ MODULE WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR MECHANICAL EQUIPMENT. —�- I Q ROOF OBSTRUCTIONS R324.6.2 SETBACK AT RIDGE: i ® 36"ACCESS PATHWAYS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN 1 I ® 18"ACCESS PATHWAYS THESE DRAWINGS ARE SUBJECT TO AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A 1 HORIZONTAL RIDGE. PROPERTY LINE e COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 e i ROOF ACCESS POINT REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA NOT LESS THAN A EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A I ; HORIZONTAL RIDGE. RENEWABLES ENGINEERING INC. R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS I - Current AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED ; I ,`�Qf NEW y d�eneWables THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE I AND RESCUE OPENING.A 364NCH-WIDE PATHWAY SHALL BE doEngineering 1 L PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. ; I 00�R A. �'/ F CURRENT RENEWABLES 1.NOTES: MINOR FIELD ADJUSTMENTS ALLOWED BASED ' I * * ENGINEERING INC. 1760 CHICAGO AVE SUITE ON ACTUAL SITE CONDITION AND MEASUREMENTS. r RIVERSIDE CA 82507 PHONE: 1 �7 Cy PHONE: ENG.D5-1-1733 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS I I wwwc CONTRACTOR INFO INCORPORATED INTO THE 2017 NEC AND UL ; i �`O 106793 STANDARD 1741. I 239'-6" A'Q� 3. EXISTING ROOF VENT SHOULD NOT BE ' FESSIONP� COVERED. Exp:9/30/2025 -amn* iSTAMPED 05/08/2024 I, w EZSYS0 ELEMENT ENERGY LLC. Co 1 I / 7470 SOUND AVENUE,MATTTfUCK, N I NEW YORK,11952 i PH:(639 779 7993 1 I � servicesLnle2sys.com 1 Licence-ME-52689 1 e � e I (MASTER ELECTRICIAN) t Licence-HI-67461 O ; (SUFFOLK HOME IMPROVEMENT) I MSP UM SCOTTCLARK i f I 595 KERWIN BLVD, i GREENPORT,NY 11944 FENCE C PVSUMMARY - / 1 (KW��C)SIZESTC 425 X 16 = .800 FENCE/GATE / SHED � � PTC 398.1 x = .1s 870 SYSTEM SIZE 5.120 @240 (KWAC) IINKO ENLARGED VIEW M MODULES 16 QTr : 16 KM 25N-548HIA-B ROOF ACCESS POINT o / MICRO rJFJ1-911 0 201 INVERTER : ENPHASE IQBMC-72-M-US UTILITY LONG)ISIAND POWER AUTHORITY ROOF OBSTRUCTION ROOF LINE Rev Description Data Q' ROOF ACCESS POINT A INITIAL DESIGN 5/8/2024 I LU,j. 1 n ; PROJECT# -2 I 8858 35 DATE DRAWN SM024 I � ' ' PROPERTY LINE Dw'I"NBY e'R SITE PLAN ' �~ SHEET# Pu-2.0 11 _ 1 11 -I -_- -- 119'-3"----- ----------- TITLE SCALE: 1/32 = 1 -0 SITE PLAN KERWIN BLVD ARRAY AREA LEGEND ARRAY ROOF ROOF TOTAL ROOF AZIMUTH #OF AREA AREA AREA AREA STRUCTURAL NOTES : uM UTILITY METER MODULES (Sq.Ft.) (Sq.FL) COVERED BY COVERED BY 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE ROOF ARRAY(%) ARRAY(%) FRAMING SUPPORTING THE PROPOSED PV INSTALLATION ONLY. MSP MAIN SERVICE PANEL #1 124^ 16 336.32 1162 28.94 28.94 2.THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. COMBINER 3. PV MODULES, RACKING,AND ATTACHMENT COMPONENTS MUST FOLLOW C❑ MANUFACTURER GUIDELINES AND REQUIREMENTS. MODULE 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR O ROOF OBSTRUCTIONS ADDITIONAL INFORMATION. 5. PRIOR TO COMMENCEMENT OF WORK,THE SOLAR INSTALLER SHALL VERIFY THE ROOF 36"ACCESS PATHWAYS FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY ® 18"ACCESS PATHWAYS INCONSISTENCY BETWEEN SITE VERIFICATION AND FOLLOWING:2x8 RAFTERS @ 16" OC TO SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 15 FT. RAIL THESE DRAWINGS PROTERE CTION USLA — COPYRIGHT PROTECTION BY US LAW. RAFTER REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR ATTACHMENT WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current 0 Renewables 16 Engineering CURRENT RENEWABLES pF NEW y� ENGINEERING INC. 1760 CHICAGO AVE SUITE A. /p� J-13,RIVERSIDE CA 92507 F3 ;; O Q F PWWWCR�ENG�cosn33 or CONTRACTORINFO r ti 1 11 O CFO 106793 an_I■�?!1_ 1 -6 0 '°'�oFEss�oNP`' EZSYSA Exp:9/30/2025 STAMPED 05/08/2024 ELEMENT ENERGY LLC. UM 7470 SOUND AVENUE,MATTITUCK NEW YORK,11952 PH:(631)779 7993 C services@e2sys.com Licence-ME-52689 I I I I I I I I I I I I I I I i IP/I/x (MASTER ELECTRICIAN Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) SCOTT CLARK 595 KERWIN BLVD, I I I I GREENPORT,NY 11944 px�//x I I I I I I I I I I I I I I I I I PV SUMMARY ROOF#1 S YSTDC)SIZE STC 425 x 16 = AN I I I I I I I I I I I I I I I PTC 398.1 1 X 1 16 1=6.370 SYSTEM SIZE-7� 5 11A �� (KWAC) MODULES 16 JINKOSOLAR 1KM425N-54HL4-B MICRO-INV.QTY 16 MICRO : ENPHASE IQ8MC-72-M-U5 INVERTER (N)16 JINKO SOLAR JKM425N-54HL4-B UTILITY LONG ISLAND POWER AUTHORITY '(LIPA) Rev Description Date A INITIAL DESIGN 5/8=24 KERWIN BLVD PROJECT q I 8858 DATE DRAWN 5WO24 DRAWN BY E.R 2 ROO F P LAN SHEET# PV-2.1 TITLE SCALE: 3/16" = 1'-0" ROOF PLAN ` TABLE 1 TABLE 2 S+ FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG s2 ATTACHMENT IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ROOF 1 16° COMP SHINGLE RAFTER 2X8 16" 64" 24"Q RAIL IRONRIDGE XR-100 RAIL OF NEWY A. r W THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR 106793 WRITTEN APPROVAL FROM CURRENT O v RENEWABLES ENGINEERING INC. SSIONP� Current Exp:9/30/2025 STAMPED 05/08/2024 Renewables 6 Engineering RAFTER MOUNT CURRENT R LES ENGINEERINGG INC.INC. 1760 CHICAGO AVE SUITE J-13,RNERSIDE CA 92507 PHONE:(951}405-1733 W W W.CRENG.C.O CONTRACTORINFO MODULE TABLE: PENETRATION S3 GUIDE FOR INSTALL 14 S2 TWO OR MORE ROWS OF PANELS CZSYS>; ROOF ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 I I I I I I I PH:(631)779 7993 servs1 I I I I I I Licence-ME-2689 2.5"MIN.EMBED. (MASTER ELECTRICIAN) I Licence-HI-67461 I I I I I I I I (SUFFOLK HOME IMPROVEMENT) I I I I I I SCOTT CLARK 595 KERWIN BLVD, NOTE:INSTALL IRONRIDGE HALO ULTRA GREENPORT,NY 11944 GRIP ATTACHMENT"RAFTER CONNECTION'PER MANUFACTURER'S STACKED STAGGERED FULLY STAGGERED PVSUMMARY WRITTEN INSTRUCTIONS(2-#14 X 3"X RD SYSTEM SIZE STC azs x 1s = .Boo STRUCTURAL WOOD SCREWS TO EXISTING (MOC) RAFTER) ENLARGED VIEW ONE ROW OF PANELS PTC 398.1 1 x 1 16 1=6.370 SYSTEM SIZE 5.120 @240 (KWAC) MODULES 16 IINKOSOIAR JKM425N-54HL4-B I I I I I I I I I I I I MICRO-INV.QTY 15 MODULE MICRO I INVERTER ENPHASE IQBMC-72-M-US I I I I I I I I I I I UTILITY LONG GLAND POWER AUTHORITY '(LIPA) FULLY STAGGERED STACKED/STAGGERED SEE ENLARGED VIEW - Rev °es"'Pti°" °a}e A INITIAL DESIGN 51=024 sl rDRAWN 8858 ROOF 5=024 E.R PV-3.0 ATTACHMENT DETAILS STRUCTURAL BACKFEED BREAKER`SIZING OF NE IV ELECTRICAL EQUIPMENT LIST �P� � wyo� MAX CONTINUOUS OUTPUT 1.33A @ 240V 'C 21.28 1XI 1.25 1 = 126.60AMPS 130A BREAKER-OK S.NO. ITEMS DESCRIPTION CITY. CID �O R9CI �- SEE 705.12 OF 2017 NEC JINKO SOLAR * � 2 1 PVMODULE JKM425N-54HL4-B 16 ACCOUNT NO : 9672025750 M v LU 200 X 1.20 = 240 n LU 240 1-1 200 1 = 140AALLOWABLE BACKFEED 2 D99128 - - - " - 2 MICROINVERTER ENPHASEIQ8MC-72-M-US 16 METER NO: 98413254 m �.1 1 CTRICP� 3 COMBINER ENPHASE COMBINER BOX 1 ARO SS101.1P�' X2-IQ AM1-240-4 STAMPED 05/08/2024 (E)UTILITY METER TO UTILITY GRID _ SE DRAWINGS ARE SUBJECTTO 3 COEPYRIGHT PROTECTION BY US W. ANY FORM IS (N)ENPHASE (E)200A RATED EXPRESSLY FORBIDDEN WITHOUT PRIOR COMBINER BOX MAIN SERVICE PANEL © WRITTEN APPROVAL FROM CURRENT 1PH.120I240V 60HZ RENEWABLES ENGINEERING INC. (E)200A/2P MAIN --- - -- --- ---- -------- CELL WIRE LESS BREAKER MODEM COMMS (TOP FED) Current IQ GATEWAY Renewa�t 1 16 Engineering NJ 1`5A CURRENT RENEWABLES ENGINEERING INC. TO OTHER 1760 CHICAGO AVE SUITE 1 BRANCH OF I I �� PHONE��)40�73333�7EPV MODULE I I •� WWW.CRENG.CO (N OA/fN (N)30AI2P PV CONTRACTORINFO I (N3z�/ I I BREAKER 2 BRANCH OF 8 r-----= �IJ L----------------- ---------------------------------- PV MODULE L-------e C2 SYS9. L----------- - - - - - - B ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, MODULE JINKO SOLAR NEW YORK,11952 MANUFACTURER = PH:(631)779 7993 - - _ - "--_-- _ (E)GROl1NDING ELECTRODEI- -- - CONDUCTOR 96 BARE COPPER services@e2sys.com MODULE MODEL JKM425N-54HL4-B Licence-ME-52669 (MASTER ELECTRICIAN) Licence-HI-67461 MODULE(W) 425 (SUFFOLK HOME IMPROVEMENT) MODULE PTC(W) 398.1 - SCOTT CLARK MODULE Isc(A) 13.58 NOTE: 595 KERWIN BLVD, MODULE Voc(V) 38.95 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS GREENPORT,NY 11944 MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. MODULE Vmp(V) 32.37 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH srsTEMSIZE SUMMARY PROPER JUNCTION BOX AT EACH END PER 690.31A (KMo) STC 425 x 16 =6.800 PTC 398.1 X 16 = .370 WIRE CALCULATION (KWAC) 5.120 @240 STARTING ADJUSTMENT MAXIMUM nNKO SOLAR CURRENT FACTOR FOR ADJUSTED CURRENT ICoaN STARTING TEMPERATURE MODULES = 16 16 JKM425N-54HL4-B CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION : TAG DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO MICRO : ENPHASEIQ8MC-72-MH15 CITY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (°C) CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS INVERTER O GB n o 310.15(B)(16) "r""'r IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY LIPA, 2 12 SKU:Q-12-RAW-300,THHN A - "� - - - -` N/A FREE AIR 30 90° 10.64 0.96 1 28.80 13.30 Rev Descr4ttan Data 1 8 THWN-2 BARE COPPER-(GROUND) A INITIALDESIGN 5AM24 3 10 THWN-2 COPPER-(L1,L2) B 1 g THWN-2 COPPER-(GROUND) ease 3/4"PVC 40 90° 21.28 0.96 1 38.40 26.60 PROJECT# e IDATE DRAWN SWO24 DRAWN BY E.R SHEET# PV-4.0 TITLE ELECTRICAL 3LD BACKFEED BREAKER SIZING ELECTRICAL EQUIPMENT LIST OF NEwy o MAX.CONTINUOUS OUTPUT 1.33A @ 240V ( OE MAlyj ,A 21.28 1XI 1.25 1 = 126.60AMPS 130A BREAKER-OK S.NO. ITEMS DESCRIPTION CITY. co �O R9c SEE 705.12 OF 2017 NEC JINKO SOLAR I * Qj €; _ 1 PV MODULE 16 ACCOUNT NO : 9672025750 200 X 1.20 JKM425N-54HL4-B= 240 n � D W 240 - 200 = 40AALLOWABLE BACKFEED 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 16 METER NO: 98413254 2� 09912B CTRICP� 3 COMBINER ENPHASE COMBINER BOX 1 ARO�SSIONP� X2-IQ-AMl-240-4 STAMPED 05/08/2024 (E)UTILITY METER TO UTILITY GRID 3 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. (N)ENPHASE (E)200A RATED REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR COMBINER BOX MAIN SERVICE PANEL WRITTEN APPROVAL FROM CURRENT 1)200A//240V 60HZ RENEWABLES ENGINEERING INC. (E)200A/2P MAIN CELL WIRELESS BREAKER Current MODEM COMMS (TOP FED) Rene-w-ablas IQ GATEWAY 1 Engineering 2 A N)15A. ` ' ' CURRENT RENEWABLES ENGINEERING INC. TO OTHER •�• 1760 CHICAGO AVE SUITE 1 BRANCH OF 8 LOAD PHONE:(95SID�E-1 B2507 PV MODULE N 'r\' . (N)�.� WWW.CRENG.CO (N)30A/2P PV •my- CONTRACTOR INFO =N)MAO� BREAKER �� `• 2 BRANCH OF 8 PV MODULE N • CZSYSL4 B ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTI UCK, MODULE JINKO SOLAR MANUFACTURER - NEW 30 11952 (E)GROUNDING ELECTRODE PH:(631)779 7993 CONDUCTOR#6 BARE COPPER services[ale2sys.com MODULE MODEL JKM425N-54HL4-B Licence-ME-52669 (MASTER ELECTRICIAN) Licence-HI-67461 MODULE(W) 425 (SUFFOLK HOME IMPROVEMENT) MODULE PTC(W) 398.1 SCOTT CLARK MODULE Isc(A) 13.58 NOTE: 595 KERWIN BLVD, MODULE Voc(V) 38.95 1 CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS GREENPORT,NY 11944 MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. MODULE Vmp(V) 32.37 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8'ABOVE ROOF WITH PV sysrEM slzE SUMMARY PROPER JUNCTION BOX AT EACH END PER 690.31A (KWDC) STC 425 x 16 =6.800 PTC 398.1 X 16 =6.370 WIRE CALCULATION SYSTEM SIZE ; 5.120 @240 (KWAC) STARTING ADJUSTMENT MAXIMUM JINKO SOLAR STARTING TEMPERATURE MODULES : 16 JKM425N-54HL4-B CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT MICRO-INV.QTY 16 TAG DESCRIPTION APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO MICRO ENPHASE IQ8MC-72-M-US QTY. SIZE(AWG) SIZE 8�TYPE AMPACITY RATING (°C) CONDUCTORS FACTOR CONDUCTORS AMPACITY CONDUCTORS INVERTER LONG IS LAND POWER AUTHORI 310.15(B)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY UTILITY (LIPA) SKU:Q-12-RAW-300,THHN A 2 12 N/A FREE AIR 30 90° 10.64 0.96 1 28.80 13.30 1 8 THWN-2 BARE COPPER-(GROUND) Rev INITIAL Date rDATEDRAWN INITIAL DESIGN 5/812024 3 10 THWN-2 COPPER-(L1,L2) B 3/4"PVC 40 90° 21.28 0.96 1 38.40 26.60 88se 1 8 THWN-2 COPPER-(GROUND) 5=024 E.R PV-4.1 ELECTRICAL SLID EXISTING SERVICE PANEL PHOTOS of NEW CAP M���v 099128 2N�O 4 CTRICP'� STAMPED 05/08/2024 ~ _ THESE DRAWINGS ARE SUBJECT TO - --`--------- --=- COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR Lie WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables IW Engineering k, CURRENT RENEWABLES ENGINEERING INC. ';•',Jwtly' �' 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951}405-1733 --- 1 e '�°:' :,{�• WWW.CRENG.CO CONTRACTOR INFO LA ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTRUCK, < _ NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52669 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) SCOTT CLARK ! 595 KERWIN BLVD, GREENPORT,NY 11944 PV SUMMARY SYSTEM SIZE(KWDC) STC 425 X 16 = .800 !- PTC 398.1 1 X 1 16 = .370 S S E(KWAC) 5.120 @240 MODULES SOLAR 16 ��,• • JKM425N-54HL4-B •;- MICRO-INV.CITY 16 MICRO ENPHASE IQBMI:-72-M-US _ INVERTER R,,yy'a. -` :• - —,—!�! - �. - UTILITY LONG ISLAND POWER A ORITY yak�. = 5 q#,",•":y .;i:'" Rev DesrYiption Date ' + A INITIAL DESIGN 5182024 PROJECT# 81158 DATE DRAWN 5182024 DRAWN BY Ell SHEET# PV-1.2 TITLE ELECTRICAL PHOTOS MATERIAL LIST OF NE►Nr P� Mav�� ELECTRICAL EQUIPMENTS Qn- PART TYPE PART NUMBER DESCRIPTION 2 099,28 z 16 MODULE JKM425N-54HL4-B JINKO SOLAR JKM425N-54HL4-B ��a CTRIG 16 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US AROFEssl 1 COMBINER X-1Q-AM1-240-4/4C X-1Q AM1-240-4/4C STAMPEDO5/08/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current -Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951}405-1733 W W W.CRENG.CO CONTRACTOR INFO BREAKER/FUSES (�®E Qn• PART TYPE PART NUMBER DESCRIPTION 10 CZSYS0 1 BREAKER 30A 2-POLE BREAKER(S) GENERAL 30A 2-POLE BREAKER(S) 2 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTRUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) RACKING SCorr cwRK Qn• PART TYPE PART NUMBER DESCRIPTION 595 KERWIN BLVD, GREENPORT,NY 11944 12 RAILS&SPLICES XR-100-168B XR100, RAIL 168" BLACK PV SUMMARY SYSTEM SIZE STC 425 X 16 = .800 8 RAILS&SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 (KWDC) PTC TC 39R.1 X 16 = .370 28 CLAMPS& GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK SYSTEM SIZE 5 caM (KWAC) 240 8 CLAMPS & GROUNDING UFO-STP-35MM-B1 STOPPER SLEEVE, 35MM, BLACK MODULES 16 11KM42SN54HL4-B 2 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG LOW PROFILE MICRO-INV. ICRO INV.CITY : 1s INVERTER ENPHASE IOBMC-72-M-US 28 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP, BLACK UTILITY I ILUNG ISLAND POWER AUTHORITY (LIPA) Rev Description Date A INITIAL DESIGN 5la/E024 PROJECT# 8858 DATE DRAWN 5/WO24 DRAWN BY E.R SHEET# PVS.0 TITLE BOM CAUTION �, New y . ,�P OE MA11/j'Afq O,A MULTIPLE SOURCE OF POWER O7ju ��� •(,l G m LU oss�za 2 PHOTOVOLTAIC C M— BOA TRICP� ��Ro Sslo Cl 1 > STAMPED 05/08/2024 690.12 _ I Co z THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. LiJ REPRODUCTION IN ANY FORM IS Y EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT { - - RENEWABLES ENGINEERING INC. TURN RAPID I- - PV SYSTEM AC DISCONNECT - - SHUTDOWN SWITCH TO • CURRENT Current Renewables THE"OFF"POSITION TO AC - AC NORMALOPERATING V• VOLTS SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Engineering CUNT AND REDUCE SHOCK RNING"WA ENGINEERING FABLES 1750 CHICAGO AVE SUITE HAZARD IN THE ARRAY P M DUAL POWER • - �ARRAY J-13,RNERSIDE CA 92507 PHONE:(951}405.1733 690.56(C)(1)(B) SECOND • - PHOTO-V• • W W W.CRENG.COCONTRACTOR INFO RATED AC OUTPUT CURRENT-21.28 AMPS AC NORMAL OPERATING VOLTAGE -240 VOLTS ® 690.54 COMBINER MAIN SERVICE PANEL CZ SYS - - OPTIONAL SOLAR LOAD CENTER UTILITY METER ELEMENT LLC. ARRAY \ 7470 SOUND AVENEUE,MATTI UCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.wm JB PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL erAces@e2syz6B9 (MASTER ELECTRICIAN) PANEL IS AC DISCONNECT PER NEC690.17 Licence-HI-67461 I � (SUFFOLK HOME IMPROVEMENT) L — _j SCOTT CLARK INVERTEROUTPUT CONNECTIONI I ' 595 KERWIN BLVD, I GREENPORT,NY 11944 •• NOT RELOCATE THIS NEC 690.31(G)(3)$(4),CRC R324.7 wsLndMARv OVERCURRENT DEVICE I SYSTEM SIZE (UNLESS BUSBAR IS FULLY RATED) ( � sTC 98. m 705.12(D)(2) PHOTOVOLTAIC POWER • - 3?9TE PTC 398.1 (KWAC) 5.120 @240 JINKO OLAR EVERY 1VON CONDUIT AND ENCLOSURES MODULES 16 JKM42 N-54 JKM425N-54HL4-B ICRO•INV.OTY 16 NOTES. N1 ER : ENPHASEIO8MC-72-M-u5 INVERTER UTILITY ONG S D ER ORTTY LIPA) 1. nec ARTICLES 690 AND 705 AND nec SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Desmip0on Date A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A INITAILDESIGN 5JaM024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE FDRAVMN.BY q BBse WORK. C. AERIAL FONT. WN 5=024 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN E.R THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BE PV-61)HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. s� www.jinkosolar.Gorn oJinKo . Engineering Drawings Building Your Trust in Solar Tiger Ne® N_fi/pe - 3 , . Cu-°n4Vdtogo6Power-Votla9e Tyr°1�a.o e�c»°r.ae� C—es lse.Voc,Prs 5.:; 4C. ill ,3?.6R4y :xN:zC I 1aD 54H l4-B _ G;13'0 12 THESE DRAWINGS ARE SUBJECT TO 425 ■ � '� a REPRODUCTION COPYRIGHT ION TECTION BYIN IS LAW. ®��'0 y�r�i. a REPRODUCTION IN ANY FORM IS u ' EXPRESSLY FORBIDDEN WITHOUT PRIOR liin.pt. Ir{; s r ar WRITTEN APPROVAL FROM CURRENT (° i RE:NEWABLES ENGINEERING INC. ALL-BLACK MODULE _ `,�SaL'i}r:G ri:- t��4.='53V 1 ° s 1a 15 Z 25 m ss a m N-Type eaa swe e°e2 Current vauex ® m eea,=a°�1�rc: Ban a 1[I abl e s Positive power tolerance of 0-+3% Engineering CURRENT RENEWABLES IEC61215120161,IEC61730(2016) 3 -s-.en ENGINEERING INC. IS09001:2015:Quality Management System Mechanical Characteristics1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 ISO14001:2015:Environment Management System Celt Type N type Mono-crysicPine PHONE:(951)405.1733 W W W.CRENG.CO ISO45001:2018 _�_ _J —n y';..' Occupational health and safety management systems I A-A Dimensions 1722x 1134x3Omm(67.79x44.65x1.18 inch) CONTRACTOR INFO We6 t ;r_, `' -_ _.'.i 22 '1(a8150 2�`7",;,._ Key Features Front Glass 3.2mm,Anti-Reflection Coating, High Transmission,Low Iron,Tempered Glass � (Two paGets=One stock) • 'Trade)k '.' '. MEN" :.'.. ®.1 Anodized A ,-. ,Alb *' :") ..� - 36'flcy s,�72pc5YsJaY 936pcs'/,'4D;HQ Coniotner Junction Box tP68 Rated C2 SYSS SMBB Technology Hot 2.0 Technology ora t-.Cdtiles`::, 4.0 rvs TUV .;•z''-..'i.r...,,. (+:400nvnttf"1. or CusiorradkCength, -,.,_I . Better right trapping and current collection to improve HOT The N-type module with Hot 2.0 technology has better ® module power output and reliability. 2.0 reffabMity and lower UD/LERD. ELEMENT ENERGY Ll C. 7470 SOUND AVENUE,MATTTTUCK, NEW YORK,11952 SPECIFICATIONSPH:(631)779 7993 services@e2sys.com Module Type JKM425N-54HL4-B Licence-ME-52689 PID Resistance Enhanced Mechanical Load SIC NOCT (MASTER ELECTRICIAN) �,I {{{{ Licence-HI-67461 Excellent Anti-PID performance guarantee via a Certified to withstand:wind load(2400 Pascal)and snow Maximum Power(Pmox) 425Wp 320Wp (SUFFOLK HOME IMPROVEMENT) `it t optimized mass-production process and materials a4roro load(5400 Pascal). control. I✓:admum Power Vofiage(Vmp) 3237V 30.19V SCOTT CLARK Maximum Power Current(Imp) 13.13A 10.60A Open- cecuiiyoltage(Voc) 3e.95V 37.00v 595 KERWIN BLVD, GREENPORT,NY 11944 Short-circuit Current(Lsc) 13.58A 10.96A Durability Against Extreme Environmental Module Efficiency STC(%j 21.7e% i PV SUMMARY BY g t\ aEur SYSTEM SIZE ® lvL�-..i [ �CyCLE I� ��W,�- Operating Temperature('C) -40°G-+85°C (KWOC) STC 425 X 16 = .800 Conditions ±ir ` v M— High sail mist and ammonia resistance. Maximum system voltage 1000VDC(IEC) 1 PTC 398.1 X 16 = .370 Maxmum series fuse rating 25A SYSTEM SIZE 5.120 @240 (KWAC) Power tolerance 0--r3% - MODULES 16 1JKM42SN-54HL4-B1NKO SOLAR Temperature coefficients of Prtwx -0.29%J°C MICRO-INV.CITY 16 LINEAR PERFORMANCE WARRANTY Temperature coefficients of Voc -0.25%,°C MICRO ENPHASE IOBMC-72-M US INVERTER Temperature coefficients of Isc 0.0455'/°C UTILITY LUNG ISLAND POWER AUTHORITY e 100% NonWnal operafing cell temperature (NOCT) 45±2°C - '(LIPA) u 99% 25 Year Product Warranty -STC:- Irradiance 1000W/m2 ® Cell Temperature 25°C AM=1.5 Rev Desoption Date A INITIALDESIGN 5WO24 a 30 Year Linear Power Warranty NOCT: c Irradiance 800W/m2 ® Ambient Temperature 20°C AM=1.5 Wind Speed 1 m/s m 87.4% `c c _ PROJECT# 8858 u years0.40%Annual Degradation Over 30 years DATE DRAWN 51%,M4 t is 3o 02023 Jinko Solar Co.,Ltd.All rights reserved. Specifications included in this datasheet are subject to change without notice. JKM405-425N-54HL4-B-F3C2-EN DRAWN BY E.R Datasheet valid in Europe only. SHEET# PV-7.0 TITLE MODULE SPEC 'Z ENPHASE. IQ8MC Microinverter INPUT DATA(DC) UNTTS IQSMC-72-M-US r Commonly used module pairings' W _ 260-460 - - wModulecompetibility To meet compatibility,PV modules must be within the following mm input DC voltage and max.module 1. i - Module compatibility can be checked at https-.//enchase.comAnstallers/n icroinverters/calculator. ' -- -- - - - -- --- ` � - -- -- - - - - - _ _-- -- - - ---- - - - -- -- -- - THESE DRAWINGS ARE SUBJECT TO 11 MPPT voltage range V 25-45 COPYRIGHT PROTECTION BY US LAW. - REPRODUCTION IN ANY FORM IS Operating range ! v i 18-58 EXPRESSLY FORBIDDEN WITHOUT PRIOR Min✓Max.start voltage V - 22/58 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Max.input DC voltage V I 60 Max.continuous operating DC current A - 14 Current Max.input DCshort-circuit current ! A � 25 Renewables ' Max.module i. - - - A .20 -�---- ------`- -------------.----_. ____------- ---__.___ _---"------_-_._-_----------__.-__.---- - Engineering Overvoltage class DC port DC port backfeedcurrent '--- mn -----~ -- i o - - CURRENTRENEWABLES ENGINEERING INC. + 1 PV array configuration Ungrounded error,no additional DC side protection required;AC side protection requires max 20 A per branch circuit 1760 CHICAGO AVE SUITE ! J-13,RIVERSIDE CA 92507 r° PHONE:(95IM05-1733 ��'---- - ---- ----- -.— "--...--- --`---'- ---'--'----------' - --" - W W W.CRENG.CO Peak output power VA - 330 - _ _ 315 CONTRACTOR INFO Max.continuous output power ' VA 320 310 ---- - -- ---" N - - -- -- -- - - - - omina(gndvoltage(L-U v - 240,spLt-phase(L-0,1180° 208,single-phase(LL),120°- I Q8 M C Microinverter Easy to install Min./Max.grid Voltage V 211-264 183-229 -------------- _ _ -i-------_— - ----- --- " -1—_ ------ - - — dim Our newest I08 Series Microinverters are the industry's first microgrid-forming',software- I Lightweight andoonipactwrthplug- I Max.continuous output current A 1.33 149 I- -and'play.connecIors- _ _ _ _ _ _ _ __ _ _ L���� defined microinverters with sprd-phase power conversion capability to convert DC power to Nominal frequency Hz 6D 8 AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary a Power line communication(PLC)' i I - Exteridedfrequencyrange. Hz _ "47-68 application-specific integrated circuit(ASIC),which enables the microinverter to operate in � between components - 'I - grid-tied or off-gridmodes"This chip-sbuitin advanced 55-nmtechnologywithhigh-speed AC short circuit fault currentmerthree I i ELEMENT ENERGY LLC. digital icandhassu superfast changing g g Faster installationwithsimpietwo-wire A_ 2.70 7470SOUNDAVENUE,MATTITUCK, fg logic pe response limas to chap in bads and rrd everts,alleviating cycles ; constraints on battery sizing for home energy systems. cabling - Max:units per 20A(L-L)branch circuit a 12 - t0 NEWYORK 11952 PH:(631)779 7993 _ High productivity and reliability Total harmonic distortion ; services@e2sys.com % 45 4 — Licence-ME-52689 EnphaseI Produces power even when the grid is (MASTER ELECTRICIAN) clown* Overvoltage class AC port III Licence-HI-67461 More than one million cumulative hours AC port backfeed current mA 18 (SUFFOLK HOME IMPROVEMENT) oftesting Powerfactorsetting - 1.0 _ SCOTT CLARK Enphase Energy System, IQ8 Series Microinverters redefine Class Itdouble insulated enclosure Part of the En P 9Y Yst � Grid-tied power factor(adjustable) j i 0J35 leading...0.85lagging 595 KERWIN BLVD, I08 Series Microinverters integrate with reliability standards with more than one %Optimized for the latest high-powered - " - - - - - - - --. - - the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules i Peak efficiency % 97.4 97.2 GREENPORT,NY 11944 Enphase App monitoring and analysis testing,enabling an industry-leading CEC 97.0 96.5wegteeficency - PV SUMMARY software. limited warnarny of up to 25 years- Mierogrid-forming Nighttime power consumption mW- _ 33' 25 SYSTEM SIZE Complies with the latest advanced grid MECHANICAL,ITA UNITS (KWDC) STc 425 x 16 = .800 ® support - - - PTC 398.1 X 16 =6.370 Ambient temperature range =40•Cto 65•C(-40T to 149-F) • Remote automatic updates for the — SYSTEM SIZE 5.120 @240 a , latest grid requirements Relative humidity range l 4%to 100%(condensing) (KWAC) JINKO SOLAR _ Configurable to support a wide range `DC connector type-' Stdubli MC4 MODULES : 16 JKM425N-54HL4-B MICRO-INV.OTY 16 Connect PV modules quickly and easily IQ8 Series M)Croinverters are UL L"lsted of grid profiles Dimensions(H•IN-D);Weight 212 mm(8.3")a 175 mm(6.9")a 30.2 mm(1.2");IJ kg(2.43 Ibs)-_ - -_-- MICRO-------------- ------ ---- --- - ---- -. -- - "-- -- — - - - ENPHASE IQBMC-72-MUS to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans INVERTER -_--_'--.---_--- -----'---.--__.__----'-_-----_..-."-_------__-._--_- -'----.---- -.-- LONG IS LAND POWER AUTHORITY integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) UTILITY 9 e9 Approved for wet locations;Pollution degree j Yes;PD3 '(LIPA) installed according to the manufacturer's - I Enclosure - - Class II double-Insulated,corrosion resistant polymeric enclosure instructions. NOTE: - ' j 108Mic'oirvertes cannot bemxad together with Environ.category;UV exposure rating NEMATypeB;outdoor ri previous generations of Enphase mlcroim • erters Rev Description Date .(107 Series,106 series,eta)in the same system. - - - - A INITIAL DESIGN 5182024 IQ Gateway is required to change the default grid CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 •Meets In 1741 only when Installed with lO System Comroger2and 3. I profile at the time of Installation to meet the local j Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 sectloh 690.12"and Authority Having Jurisdiction(AHJ)requirements. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when Installed according to the manufacturer's Instructions. 02023 Enphase Energy.Ali rights reserved.Enphase,the a and CC logos,IQ and certain other marks fisted at '� 0)Noerdorcod DC/AC retie. [DRAWN ROJECT# 8858 httpsJ/enchase.com/tmdemark-mage tidplM are trademarks of Enphase Energy,Inc in the US and other countries. (2)Nominal voltage range can be Wended beyond nominal If required by the utility. DATE DRAWN 5)82024 Data subject to change. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 (3)Limits may wry.Refer to local requirements to define the number of mlcroinvertvs per branch in your area. 108MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 BY E.R HEET# PV-7.1 TITLE MICROINVERTER SPEC IQ Combiner 4/4C Data Sheet Enphase Networking MODEL NUMBER IQ Combiner 4 IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI CIZ20±0.5%) i !X-IQ-AM7-240-4 and consumption monitoring(±2.5%).Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to I X2-IQ-AM1-240 4(IEEE 1547-2018) deflect heat. ' IQ Combiner 4C IQ Combiner 4C with 10 Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0.5%) THESE DRAWINGS ARE SUBJECT TO Q Combiner 4i4 C X-IQ-AM1-240-4C and consumption monitoring(±2.5%).Includes Mobile Connect cellular modem(CELLMODEM-M1-06-SP-05),a plug-and-play COPYRIGHT PROTECTION BY US LAW. The IQ Combiner 4/4C with IQ Gateway and X2-IQ-AMl-240.4C(IEEE industrial-grade cell modem for systems up to60microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the( ) REPRODUCTION IN ANY FORM IS US Virgin Islands,where there is adequate cellular service in the installation area)Includes a silver solar shield to match the EXPRESSLY FORBIDDEN WITHOUT PRIOR integrated LTE-M1 cell modem(included IQ Battery and 10 System Controller and to deflect heat. WRITTEN APPROVAL FROM CURRENT only with IQ Combiner 4C)consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) RENEWABLES ENGINEERING INC. Supported microinverters IQ6,IQ7,and I08.(Do not mix 106/7 Microinverters with IQ8) interconnection equipment into a single ------ ------ - ---- - - - ------ - -- Current } Communications Kit - - Cuur1 entLt - enclosure. It streamlines IQ Microinverters and COMMS-CELLMODEM-Ml-06 Includes COMMS-KIT-01 and CELLMODEM-Mt-06-SP-05 with 5-year Sprint data plan R4d�e�4>t�1es CELLMODEM-Ml-06-SP-05 -4G based LTE-Mt cellular modem with 5-year Sprint data plan ' - - CELLMODEM-MI-06-AT-05 -4G based LTE-Ml cellular modem with 5-year AT&T data plan -- - - - i storage installations by providing a consistent, --------- -- ------------ ----- --- - . --- --- - ---— --- —- — - - Engineering d'(� !` +Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. r eENPHASE pre-wired solution for residential applications. i BRK-10A-2-240V Circuit breaker.2 pole,1 OA,Eaton BR21 0 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 CURRENT RENEWABLES I ' BRK-20A-2P•240V Circuit breaker,2 pole,20A,Eaton BR220 ENGINEERING INC. It offers up to four 2-pole input circuits and 1 BRK-15A-2P-240V-8 Circuit breaker,2 pole,15A,Eaton BR2158 with hold down kit support 176D CHICAGO AVE SUITE BRK-20A-2P-240V-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support J 13,RIVERSIDE CA 92507 'J ( Eaton BR serves busbar assembly_ �_.____ ___. ___________.____._. __ ______—____.__ _______._ ___ __ _-__ -________ --__________ __ . _ ____1 PHONE:(951)405-1733 XA-SOLARSHIELD-ES Replacement solar shield for lQ Combiner 4/4C WWW.CRENG.CO - -r XA-PLUG-120.3 Accessory---receptacle for--Power--Line Carrier-- in-IQ-Combiner--4/4C(required for EPLC-01)- ' • „ CONTRACTOR INFO - - i X-IQ-14A-HD-125A-� -- _-- Hold-down kit for Eaton circuit breaker with screws —---- ------ - - ------ � I Consumption monitoring CT ^A pair of 200A split core current transformers ;n '�`•` r Smart �(CT-200-SPLIT/CT-200-CLAMP) 1 ELECTRICAL SPECIFICATIONS Includes IQ Gateway for communication and control Rating continuous duty ; g --- Includes Mobile Connect cellular modem -----—----------- —- ----------- '-- -----_-- —- C��Y�Q I System voltage 120/240VAC,60 Hz (CELLMODEM-M7-06-SP-OS),included only with r.- ------- --- --- i (Eaton BR series busbar rating 125A IQ Combiner 4C L_ __ _ --- __- ----- ELEMENT ENERGY LLC. includes solar shield to match Enphase IQ Battery Max.comuouscurrentreting 64A - �- -_ _—_-J 7470 SOUND AVENUE,MATTITUCK, aesthetics and deflect heat Max.continuouscurrentrating(inputfromPV/storage) 64A � _ _ �-- --- ------ �--------- i NEW YORK,11952 k Supports Wi-Fi,Ethernet,or cellular connectivity Max.fuse/circuit rating(output) 90A PH:(631)779 7993 Optional AC receptacle available for PLC bridge f Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not Included) _ _ - - _-E services,[de2sys.Com Provides production metering and consumption Licence-ME-52689 P 9 P Max.total branch circuit breaker rating(input) BOA of distributed generation/95A with IQ Gateway breaker included _ ____ __ _ ___ __ _ _____ ___ (MASTER ELECTRICIAN) y�l i monitoring flQGatewaybreaker - -J- 10Aor15AratingGE/Siemens/Eaton included -_-_______ _ __.___.__.— __-f Licence-HI-67461 �1L. i---_---------- — - -- - ------- --------- --- --------------- -- -- L i Production metering CT 200A solid core pre-installed and wired to IQ Gateway (SUFFOLK HOME IMPROVEMENT) Simple MECHANICAL DATA SCOTT CLARK • •i Dimensions(WxHxD) 37.5 cm x 49.5 cm x 16.8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mounting brackets. X IQ-AM1240-4C _ t Mounts on single stud with centered brackets -_ _--- __—_� —___- --___--__-_- - --_-------- -_------- 595 KERWIN BLVD, X2-IQAMl-240-4C(IEEE 1547:201B) Supports bottom,back and side conduit entry weight 7.5 kg(16.51bs) GREENPORT,NY 11944 Allows up to four 2-pole branch circuits for 240VAC I Ambient temperature range 40°C to+46°C(-40°F to 1151F) l - - ----- --- ------ ------'---- ------ PV SUMMARY plug-in breakers(not included) Cooling Natural convection,plus heat shield SYSTEM SIZE % 80AtotalPVorstoraebranchcircuits i - - - - ---------- ------ - - _- - __ ----- -- -------------- _- -______ --, C 425 x16 =s800 9 I Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction (KWDC) -' I, -------------- ----- -_ ._.------' ---- --' - --VP- ---------_-__—_----- - -- ---------- ---� PTC 398.1 X 16 =6.370 Wire sizes 20A to 50A breaker inputs:14 to 4 AWG copper conductors J •60A breaker branch input:4 to 1/0 AWG copper conductors SYSTEM SIZE - Reliable (KWAC) s.120 @240 • Main lug combined output:10 to 2/0 AWG copper conductors' Neutral and ground:14 to 1/0 copper conductors MODULES 16 11NK0 SOLAR JKM425N-54HL4-B - Durable NRTL-Certified NEMA type 3R enclosure Always follow local code requirements for conductor sizing. MICRO-INV.QTY 16 -- ---- - - —- -- - ------ -- ------ -- - -- -- - --- - -- - - -- t Five-year limited warranty (Altitude Up to 3,000 meters{9,842 feet) MICRO INVERTER ENPHASE 148MC-72-M-US INTERNET CONNECTION OPTIONS I • Two years labor reimbursement program coverage 1 LONG ISLAND POWER AUTHORITY included for both the IQ Combiner SKU's UTILITY (UPA) Integrated Wi•FI IEEE 802.11b/g/n i I UL listed I- ----- - X IQ-AM1-240-4 y--<;� Cellular - - -- CELLMODEM-MI-06-SP-05,CELLMODEM-M1-06-AT-05(4G based LTE-M1 cellular modem).Note that an Mobile Connect � �4 X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with cellularmodem is required forall Enphase EnergySystem installations. X2-IQAM1240-4(IEEE 1547:2018) - -- - - - - - - - -------- - ---- -- IEEE 1547:2018(UL 1741-SB,31d Ed.) �Ethernet - _ - - -Optional,IEEE- 802.3,- CatSE-- (or-Cat6)- -- UTP-Et-hern--et-cable----(not-inc- luded)--- Rev Description Date COMPLIANCE A INITIALDESIGN 5182024 i Compliance,IQ Combiner CA Rule 21(UL 1741-SA) IEEE 1547:2018-UL 1741-SB,31"Ed.(X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) CAN/GSA C22.2 No.107.1,Title 47 CFR,Part 15.Class B,ICES 003 PROJECT 9 BB58 Production metering:ANSI C12.20 accuracy class 0.5(PV production) 4STE1111 L Consumption metering_accuracy class 2.5 _ DATE DRAWN SWO24 To learn more about Enphase offerings,visit etlphase.com E N P H AS E. Compliance,IQ Gateway — UL 60601-1/CANCSA 22.2 No.61010-1 - - DRAWN BY E.R IQ-C-4-4C-DS-0103-EN-US-12-29-2022 0 2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of SHEET fl PV-72 Enphase Energy,Inc.Data subject to change. IQ-C-4-4C-DS-01 03-EN-US-1 2-29-2022 TIRE COMBINER SPEC ®fir IRON RIDGE XR Rail° Family XR Rail° Family The XR Rail®Family offers the strength of a curved rail in three targeted sizes.Each size supports specific Solar Is Not Always Sunny - design loads,while minimizing material costs. Depending on your location,there is an XR Rail®to match. Over their lifetime,solar panels experience countless _ -= THESE DRAWINGS ARE SUBJECT TO extreme weather events.Not just the worst storms in years, COPYRIGHT PROTECTION BY US LAW. but the worst storms in 40 ears.High wins able of REPRODUCTION IN ANY FORM IS d Y g �P EXPRESSLY FORBIDDEN WITHOUT PRIOR ripping panels from a roof,and snowfalls weighing - - -- -- — WRITTEN APPROVAL FROM CURRENT enough to buckle a panel frame. . ____ ------ RENEWABLES ENGINEERING INC. XR Rails@ are the structural backbone _ __— __ Current preventing these results.The resist uplift, XR10 XR100 XR1000 P 9 Y P� .� ® Rerl.eVvables protect against buckling and safely r"Y .. �� XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among Engineering and efficiently transfer loads into the 1 to rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle building structure.Their superior 7 ® no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 CURRENT RENEWABLES spanning capability requires fewer ``i�'- while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. ENGINEERING INC. P 9 P tl `'''�" _ �\ ® 1760 CHICAGO AVE SUITE roof attachments,reducing the f_. C 6'spanningcapability • 10'spanningcapability 12'spanningcapability J-13.RIVERSIDE CA92507 rf l ' - Moderate load Capability Heavy load capability Extreme load capability number of roof penetrations PHONE:(951}406 1733 `f, # jam_ '}'and the amount of � �• -=-�j �'�� `� Clear&black anodized finish • Clear 8 black anodized finish Clear anodized finish WWW.CRENG.CO 3 0_. Internal splices available Internal splices available Internal splices available CONTRACTOR INFO installation time. ' Rail Selection nt The table below was prepared in compliance with applicable engineering codes and standards. Values are o based on the following criteria:ASCE 7-16,Gable Roof Flush Mount,Roof Zones 1 &2e, Exposure B,Roof C2 SYS. •- --;,� �'-�•�0 Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit ironRidge.com for detailed certification letters. :1 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTffUCK, T' •• '• I NEW YORK,11952 '4 PH:(631)779 7993 '' • • �� services@e2sys.com Force-Stabilizing Curve 90 I Licence-MERICI9 120 ( (MASTER cen eLHCTR461 Sloped roofs generate both vertical and lateral SUFFOLK HOME IMPROVEMENT) forces on mounting rails which can cause them to None bend and twist The curved shape of XR Rails® 140 XR10 I XR100 XR1I N K• Is specialty designed to increase strength In both SCOTT CLARK directions while resisting the twisting.This unique 160 595 KERW I N BLVD, feature ensures greater security during extreme •° ✓` weather and a longer system lifetime. 90 GREENPORT,NY 11944 �. PV SUMMARY 20 120 SSE (KWDC) STC 425 X 16 =6.8W 140 PTC 398.1 X 16 = .370 • .•' 16O SYSTEM SIZE(KWAC) 5.120 @240 90 MODULES : 16 1IINKO SOLAR KM425N-54HL4-B 30 MICRO-INV.OTY 16 - - 160 _ MICRO ENPHASE IQSMC-72-M-US INVERTER Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 ( UTILITY (LIPA)LONG 15LAND POWER AUTHORITY J ' XR Rails9 are IronRldge®offers All XR Rails®are made of 6000-series r�ti_ 40 Acompatible with a range of tilt leg aluminum alloy,then protected with an a 160 FlashFoot®and options for flat anodized finish.Anodizing prevents surface other pitched roof ■■i roof mounting and structural corrosion,while also providing ® 60 160 Rev Description Date attachments. applications. a more attractive appearance. _ 120 160 A INITIAL DESIGN 5/812024 Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance.- PROJECT# 8858 ®��® DATE DRAWN 51812024 IronRidge,Inc.Ail rights reserved. - J27-9523 for more information.Version DRAWN BY E.R SHEET# PV-7.3 TITLE RAIL SPEC /fir IRONRIDGE QuiCkMOunto o Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves f % When integrating with a home solar attachments THESE DRAWINGS ARE SUBJECT TO must be dependable for the lifetime of the rooftop. _ _ y � !I (`t��/j COPYRIGHT PROTECTION BY US LAW. Due to recent innovations,many asphalt shingles _ - _ REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR have bonded courses-A mount that protects without ' _ k� t the need to shingles can real) seed things up. RREENIEWABLES ENGINEERING INC.B pry 9 y P 9 °'. Halo UltraGri ®HUG is here to respect the roof. - _-- • Current Its Halo is a cast-aluminum barrier that encases the -_ =- _ - -- --- - - Renewable5 UltraGrip,our industrial-grade,foam-and-mastic = "__ - 'a Engineering seal.This allows HUG to accelerate the installation process and provide the utmost in waterproofing cuRRENr RENEwASLEs protection.Give your roof a HUG.' ''' ' ''! Miss the rafter?Try it again. Still ' luck?Install the ENGINEERING INC. _ , , move• • more 1760 CHICAGO AVE SUITE • •• , • •, •, PHONE: RIVERSIDE CA 92507 PHONE:(951}4051733 WwW.CRENG.CO . Mutti- ered Waterproofing CONTRACTOR INFO Ti .+ HUGS'ubTlzes a multi-tiered stack of comporrents to provide revolutionary Trusted Strength &Less Hassle waterlxarfing protekriion.The Halo cast-raised-perimeter foundation -aadsthe uhraGrip base—a foam- Structural capacities of HUG®were reviewed in dor mastic seal combination that many load directions,with racking rail running ZSYSs. water intrusion by adhering C With the shingle surface -cross-slope or up-slope in relation to roof pitch.- . Halo UltraGrip-is part For further details,see the HUG certification ELEMENT ENERGY LLC. of the QuickMount", 7470 SOUND AVENUE MATiTNCK - product fine. — -_ _ letters for attaching to rafters and decking. NEW YORK,11952 damPH:(631)779 7993 IronRidge designed the HUG,in combination services UltraGrip®Seal Technol _ - -_ _,_A_ with the RD Structural Screw to streamline Licence--ME-5E-52689 69 _ __ (MASTER ELECTRICIAN) HUG UItraGripuuTaesa state of-the- _ -- - installs,which means the following: Licence-HI-67461 art seal design that uses a unq _ (SUFFOLK HOME IMPROVEMEN mtio .roam-and-mastic c nT r SCOTT CLARK foam-backed adhesive provides' - . • No prying shingles entirely new flashing system do, • No roof nail interference conforms and adheres to every 2�YearWall", : 595 KERWIN BLVD, and cranny of composition shirlgtes - - Product'guaranteed free • No pilot holes necessary filling gaps and shingle ste of,impai-ring defects. • No sealant(in most cases) GREENPORT,NY 11944 (up to 11W in height). '. _- - _ • No butyl shims needed PV SUMMARY SYSTEM SIZE(KWDC) STC 425 X 16 =6.800 Attachment Structural Water Seal UL 2703 PTC 398.1 X 16 =6.370 SYSTEM SIZE 5.120 aQ240 Loading • • (KWAC) '- _ _ -' _ _ •• JINKO SOLAR _ ___- -___ _ - `-- -- •� MODULES 16 1KM425N-54HL4-B -- --- _ MICRO-INV.OTY 16 __ -- -r- --------_--------._ .�.�__.._�.----------- ---'--'----------'--..-- ------------------- ENPHASE IOBMC-72 M115 INVERTER Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to UTILITY LONG ISLAND POWER AUTHORITY Mount HUG with our custom engineered to the roof rafters,the root HUG has been and certified for the UL 441 Section UL 2703 mechanical (LIPA) deck,or both � RD(ratter-or-deck)Structural Screw,The RD tested and rated to compliance with 27"Rain Test"and and bonding ��.,1 U9 Triple Rated&Certified U lJ ( ) 4 ,�.. Structural Screw anchors HUG to the roof support 1004 Ibs of the International TAS 100(A).95 requirements.See Llrf V%) to Respect the Roof" • with an EPDM sealing washer,completing � Rev Description Data UL2703,441(27) the stack or waterproofing barriers.See uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual A INITIAL DESIGN srev2024 Irtertek TAS 100(A)-95 backside for more installation information.- of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. ® PROJECT# 8658 Id.Visit ww-Ir-patents.com for patent information.Version 1.03 DATE DRAWN SWO24 DRAWN BY E.R SHEET# PV-7A TITLE ATTACHMENT SPEC