Loading...
HomeMy WebLinkAbout50485-Z aO��g�FFO1,f�OGy� Town of Southold 4/5/2024 P.O.Box 1179 1 �. 53095 Main Rd �yTj� Sao Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45095 Date: 4/5/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 355 New Suffolk Rd, Cutchogue SCTM#: 473889 Sec/Block/Lot: 102.-6-11.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/8/2023 pursuant to which Building Permit No. 50485 dated 3/28/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Cutchogue Fire Dist of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50485 4/l/2024 PLUMBERS CERTIFICATION DATED Autho S gnature �gOfFol,��o TOWN OF SOUTHOLD moo- ay BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50485 Date: 3/28/2024 Permission is hereby granted to: Cutchogue Fire Dist 260 New Suffolk Rd Cutchogue, NY 119352037 To: install generator as applied for. At premises located at: 355 New Suffolk Rd, Cutchogue SCTM # 473889 Sec/Block/Lot# 102.-6-11.1 Pursuant to application dated 12/8/2023 and approved by the Building Inspector. To expire on 9/27/2025. Fees: Total: $0.00 Building Inspector • o��pF SOUT�oI � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 �� • io Jamesh _southoldtownny.gov �yc4UNr1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Cutchogue Fire Department Address: 355 New Suffolk Road city:Cutchogue st: New York zip: 11935 Building Permit#: 50485 Section: 102 Block: 6 Lot: 11.001 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Wlldwood Electric Inc. Electrician: Ralph Passantino Jr. License No: 4836-ME SITE DETAILS Office Use Only Residential Indoor X Basement Service Commerical X Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200a Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel 200a A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200a UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 200amp ats, 200amp breaker in generator, 1 48kw generator Notes: GENERATOR Inspector Signature: Date: April 1, 2024 355 new suffolk rd g 50UTyO� TOWN OF SOUTHOLD BUILDING DEPT. coutom 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ kf"FINAL � . [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: � C- D-Jolclr-� u DATE INSPECTOR SOUIyO� -5 oq O 3 pp\j L 1-1 k - TOWN OF SOUTHOLD� BUILDING DEPT. o�m N 631-765-1802 INSPECTION- I FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY - [ ] FIRE SAFETY INSPECTION [ ] . FIRE RESISTANT CONSTRUCTION - [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION-. [ ] PRE C/O [ ] RENTAL REMARKS: LV �I DATE I INSPECTOR ELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST) c -3 ----------------------------------- FOUNDATION (2ND) cf) ROUGH FRAMING & PLUMBING INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS tio 0 -Ctr+k PROPERTY'INFORMATION Existing use of property: Fire Department__ Intended use of property:Fire Department Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Fire Department this property? ❑Yes ®No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and'other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Ral ph Passanti no Jr. BAuthorized Agent ❑Owner Signature of Applicant: Date: December 8, 2023 STATE OF NEW YORK) SS: COUNTY OF Ralph Passanti no Jr being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is theWildwood Electric Inc. (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this da of, � Y �f eVVkV_W4(_ 20 NotaryINC JENNIFER FASANO PROPERTY OWNER AUTHORIZATION Notary Public State.of New York No.01 FA6158432 (Where the applicant is not the owner) Qualified in Suffolk County.. W Commission Exp. 01/02/202Z residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 Bu iding,beuartmentAgpliei iori' AUTHORIZATION. (Where the Applicant is not the Owner) 2-(00 NJew Su p IK tZc�. I, M.LGI�,��L_ F._!►one%c 4oJ _.-.._-.<:residing at . .. (Print property owner's name). (Mailing Address) CULT Ho UE "my, I,9-3-5�--- do hereby authorize VlwwooP I.EG� Ie, T�►L (Agent) to apply on my behalf to the Southold Building Department. - 1/4�4 (Owner's Si Lure (Date) (Print Owner's Name) t_, MAR 2 8 2024 M, a�g3 Is;Fall BUILDING-DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road = PO Box 1179 `; Southold, New York 411971-0959 r Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh(a_southoldtownnV gov - seandna'southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 12/7/23 Company Name: Wildwood Electric Inc. Electrician's Name: Wildwood Electric Inc. / Ralph Passantino Jr. License No.: 4836-ME Elec. email:ralphjr@wildwoodelectric.com Elec. Phone No: 631-236-2211 DI request an email copy of Certificate of Compliance Elec. Address.: P.O. Box 373, Rocky Point, NY. 11778 JOB SITE INFORMATION (All Information Required) Name: Cutchogue Fire District ' Address: 355 New Suffolk Road, Cutchogue, NY. 3 Cross Street: Main Road Phone No.: 631-236-2211 Bldg.Permit#: gs email: Tax Map District: 1000 Section:102.00 Block: 06.00 Lot: 11.001 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of a New 48KW Generator. Square Footage: o Circle All That Apply: Is job ready for inspection?: C YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: YES ❑ NO Issued On Temp Information: (All information required), Service Size�1 Ph❑3 Ph Size: 200. A # Meters 1 Old Meter# 91708295 Z New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑✓ Underground❑Overhead # Underground Laterals ✓ 1 2 H Frame n Pole Work done on Service? ✓ Y MN Additional Information: PAYMENT DUE WITH APPLICATION C �� goo AMP PT6 Kohler aryl kWP Pie ( vi;tl . wu�ti �ja�ct�eJ Nunemaker, Amanda From: Lanza, Heather Sent: Wednesday,January 10, 2024 1:56 PM To: Nunemaker,Amanda; Cummings, Brian A. Subject: Re: Generator No From: Nunemaker,Amanda Sent:Wednesday,January 10, 20241:52:41 PM To:Cummings, Brian A.; Lanza, Heather Subject:Generator Good afternoon, Do you need to review a proposed generator for the Cutchogue Fire District located at 355 New Suffolk Road (across the street from the firehouse)? Amanda Nunemaker Building Permits Examiner Southold Town Hall Building Department 631-765-1802 i IN RDA 0 � S3 / m WILL�Ad1°SM7rH 6 THE NORTH FORK BANX AND TRUST COMPANY z MAP OF PROPERTY m m GRATE N 67.11'09" E FOR 361.99' ci RATE 56.18 FOUND CUTCHOGUE FIRE DISTRICT b ✓� 40 g CONC. MON. SITUATE 1.9 N 62'33'10" ERB CONC. CURB 0FENCE 5 8 FENCE CUTCHOGUE • CHAIN UNK FENCE . . 0.7'S. 0.7'W. 'N. 0.7'S. , FENCE '^ TOWN OF SOUTHOLD 0,3 NCE Oq SUFFOLK COUNTY, NEW YORK b o.zs. N S.C. TAX No. 1000-102-06-11.1 ; 0 0 OLD N ASPHALT PARKING POST SCALE 1"=40' oG rn OCTOBER 10, 2023 ti\s� O 4 N \ o ` � LAMP POST SIGN k•.\ O ` "paC .I—BO�AL 1"'INct / . 1 A \ N ASPHALT PARKING LAMPPOST ✓GRATE GRATE r CRATE D . GRA GRATE� PIPE ~GRATE z F x ASPHALT PAVEMENT p O GRATE O z A ASPHALT PAVEMENT m 1 i 3 CONCRETE SLAB OVERHEAD WIRES oto 0 �°yn / $i Y z0 ZO >y� N I / POLE UTILITY — — O 84.3 35. — Ao N GRATE GRATE 16.0 11.T r� Z a: GRATE ASPHALT PAVEMENT 0 METAL STORAGE BUILDING CO C. APRON ya N HYDRANT ELECTRIC ELECTRIC E ENCLOSURES CONC. AD WELL PANEL FOR FUEL TANKS —. CORSLTIU0 _ _LAMP_POSi LAMP LAM FENCE w 6.4'E. 3 W "' S 66'1 9'30" W 275.20' Z CONC. PAD 0 4 W / o Q'" ✓AYES F/CR4THWOHL 9 G 2' �•2, A _25.3_ w o �o s -- 13LU �. = 2'' x 3'' COND S7"S o �° F 1\1 GEIVEPTop, LaC4-r,vo j RL p �Q � 0 _ _LOC x z o A K 0 L �i z m > m n x Ao N as �— E — Xr5 rrN G I L 0 0 m C 6 c� WIRES \\II11111/�� � Nathan Taft Corwin III \�P�E•oF l,/ �� ..•'Nj FT •� O / DRAIN � Land Surveyor ;# :�P , 'rGRATE = = 2• _ CONC. CURB CONC. PAD tN Successor To: Stanley J. Isaksen, Jr. LS. r- : ,� Owo Joseph A. Ingegna L.S. (7 • �� oo Title Surveys — Subdivisions — Site Plans — Construction Layout Z •• O �_ --FENCE I' PHONE (631)727-2090 Fax (631)727-1727 I (r ••.0$� S7 ;� 1.4'N. 0.3'E. I FENCE to / FEN OFFICES LOCATED AT MAILING ADDRESS /� �� \� RAIN INK FEN E 0,6'N. 0. CE 1586 Main Road P.O. Box 16 '// CAt�`s� \\` S 66'40'20" W Jamesport, New York 11947 Jamesport, New York 11947 / 4c/ N.Y.S. Lim. No. 50467 ALAN S,tNTGS 213.1 1' APP,ROvEn AS NOTED DA S FEE BY: NOTIFY BUILDING DEPARTMENT AT 631 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEUU YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTH7TPLAINNING SOUTH BOARD SOUTHSTEES N.Y,S,SO SC OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERITIFICAT .)F OCCUPANCY ELECTRICAL INSPECTION REQUIRED t/83- r KOHLER, Model: 48R �C Multi-Fuel LPG/Natural Gas 09001 Standard Features 4 KOHLEIL • Kohler Co. provides one-source responsibility for the NATIONALLY REGISTERED generating system and accessories. • The generator set and its components are prototype-tested, T .. factory-built,and production-tested. • ` *� '' -r--= • The generator set accepts rated load in one step. e A standard 5- ear/2000-hour limited warranty covers all _ systems and components. = ==� • Quick-ship (QS) models with selected features are available. See your.Kohler distributor for details. • GFCI service outlet installed on the junction box. • RDC2 Controller K o One digital controller manages both the generator set and i transfer switch functions (with optional Model RXT ATS). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to changing demand. The Kohler® Advantage o Digital voltage regulation protects your valuable • High Quality Power electronics from harmonic distortion and unstable power Kohler generators provide advanced voltage and quality. frequency regulation along with ultra-low levels of • Engine Features harmonic distortion for excellent generator power quality to o Powerful and reliable Kohler 6.21-liquid-cooled engine protect your valuable electronics. o Electronic engine management system. • Extraordinary Reliability o Simple field conversion between natural gas and LP vapor Kohler is known for extraordinary reliability and fuels while maintaining emission certification. performance and backs that up with a 5-year/2000-hour • Innovative Cooling System limited warranty. • Aluminum Enclosure o Electronically controlled fan speeds minimize generator Attractive aluminum enclosure allows installation as close set sound signature. as 18 inches from your home or small business. • Approved for stationary standby applications in locations Optional 291 kph (181 mph)wind-load-rated enclosure served by a reliable utility source. door kit is available for field installation. • Certifications • Fast Response o The 60 Hz generator set engine is certified by the Kohler's Fast-Response@ X excitation system delivers Environmental Protection Agency(EPA)to conform to the excellent voltage response and short-circuit capability ' New Source Performance Standard (NSPS)for stationary using a rare-earth permanent magnet(PM)-excited spark-ignited emissions. alternator. o cUL/UL listing, CSA certification standard are available. • Quiet Operation o Accepted by the Massachusetts Board of Registration of Kohler home generators provide quiet,neighborhood- Plumbers and Gas Fitters. friendly performance. o Meets NFPA 37 requirements for 18 in.offset for installation. Generator Set Ratings Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 120/240 1 60 44/44 184 44/44 184 120/208 3 60 48/60 167 50/62 173 4P7BX 127/220 3 60 48/60 158 50/62 163 120/240 3 60 48/60 145 50/62 150 277/480 3 60 48/60 73 50/62 75 4Q7BX 120/246 1 60 48/48 200 48/48 200 * 50 Hz options available.Contact your Customer Service representative. RATINGS:All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage.There is no overload capability for this rating. Ratings are in accordance with ISO-852&1 and ISO-3046-1.Obtain technical irrfonnation bulletin TIB-101 for ratings guidelines,complete ratings definitions,and site condition derates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.Availability is subject to change without notice. Contact your local Kohler generator distributor for availability. G4-306 (48RCLC) 6/21 f Alternator Specifications Specifications Alternator • The unique Fast-Response@ X excitation system delivers Manufacturer Kohler excellent voltage response and short-circuit capability using a Type 4-Pole,Rotating Field rare-earth, permanent magnet(PM)-excited alternator. Exciter type Brushless,Rare-Earth • Brushless,rotating-field alternator. Permanent Magnet • NEMA MG1, IEEE,and ANSI standards compliance for Leads:quantity,type temperature rise and motor starting. 407BX 4, 120/240 4P7BX 12,Reconnectable • Sustained short-circuit current of up to 300%of the rated Voltage regulator Solid State,Volts/Hz current for up to 10 seconds. Insulation: NEMA MG1 • Sustained short-circuit current enabling downstream circuit Material Class H breakers to trip without collapsing the alternator field. Temperature rise 130°C,Standby Bearing:quantity,type 1,Sealed • Self-ventilated and dripproof construction. Coupling Flexible Disc Amortisseur windings Full • Windings are vacuum-impregnated with epoxy varnish for Voltage regulation,no-load to full-load ±1.0%RMS dependability and long life. Unbalanced load capability 100%of Rated Standby • Superior voltage waveform from a two-thirds itch stator and Current p g p One-step load acceptance 100%of Rating skewed rotor. Peak motor starting kVA: (35%dip for voltages below) • Total harmonic distortion (THD)from no load to full load with 480 V,400 V 4P7BX(12 lead) 180(60 Hz),136(50 Hz) a linear load is less than 4%. 240 V 4Q7BX(4 lead) 113(60 Hz) Application Data Engine V Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type KG6208 6.2L Exhaust flow at rated kW,m3/min. (cfm) 16.4(580) 13.6(480) Natural Aspiration Exhaust temperature at rated kW,dry Cylinder arrangement V 8 exhaust, °C(OF) 649(1200) Rated rpm 1800 1500 Maximum allowable back pressure, Displacement,L(cu.in.) 6.2(378) kPa(in.Hg) 10.2(3.0) Bore and stroke,mm(in.) 101.6 x 95.25(4.00 x 3.75) Exhaust outlet size at engine hookup, Compression ratio 10.5:1 mm(in.) 76(3.0)OD Max.power at rated rpm,kW(HP) 77.0(103) 64.3(86) Cylinder head material Cast Aluminum Fuel Piston type and material High Silicon Aluminum Fuel System Crankshaft material Cast Iron Fuel type LP Gas or Natural Gas Valve(exhaust)material Forged Steel Governor type Electronic Fuel supply line inlet 1 in.NPT Frequency regulation,no-load to full-load Isochronous Natural gas fuel supply pressure, Frequency regulation,steady state :0.0% LPG (in.H2O) 1.2-2.7(5-11) Frequency Fixed LPG vapor withdrawal fuel supply Air cleaner type Dry pressure,kPa(in.H2O) 1.2-2.7(5-11) Fuel Composition Limits* Nat.Gas LP Gas Engine Electrical Methane,%by volume 92 min. — Engine Electrical System Ethane,%by volume 4.5 max. — Ignition system Electronic Propane,°%by volume 1.0 max. 87 min. Battery charging alternator: Propene, /°by volume 0.1 max. 5.0 max./°C4 and higher, by volume 0.3 max. 2.5 max. Ground(negative/positive) Negative Sulfur,ppm mass 25 max. Volts(DC) 12 Lower heating value, Ampere rating 130 MJ/m3(Btu/ft3),min. 33.2(890) 84.2(2260) Starter motor rated voltage(DC) 12 * Fuels with other compositions may be acceptable. If your fuel is Battery,recommended cold cranking outside the listed specifications,contact your local distributor for amps(CCA): further analysis and advice. Qty.,rating for-18°C(0°F) One,630 Battery voltage(DC) 12 Lubrication Battery group size 24 Lubricating System Type Full Pressure Oil pan capacity,L(qt.) 5.7(6.0) Oil pan capacity with filter,L(qt.) 7.1 (7.5) Oil filter:quantity,type 1,Cartridge G4-306 (48RCLC) 6/21 4 , ' Application Data Cooling RDC2 Controller Radiator System 60 Hz 50 Hz Ambient temperature, °C(OF) 45(113) Radiator system capacity,including engine,L(gal.) 21.3(5.6) voii�ye: 240 V O Engine jacket water flow,Lpm(gpm) 131 (34.6) 109(28.8) O Freq: 60.0 Hz Heat rejected to cooling water at rated o o O kW,dry exhaust,kW(Btu/min.) 48(2730) 44(2500) M Water pump type Centrifugal �+ Fan diameter,mm(in.) qty.3 @ 356(14) Fan power requirements(powered by engine battery charging alternator) 12VDC,18 amps each The RDC2 controller provides integrated control for the Operation Requirements generator set, Kohler®Model RXT transfer switch, Air Requirements 60 Hz 50 Hz programmable interface module(PIM),and load shed kit. Radiator-cooled cooling air, The RDC2 controller's 2-line LCD screen displays status m /min.(scfm)t 62.2(2200) 62.2(2200) Air over engine,m3/min.(cfm) 31.1 (1100) 31.1 (1100) messages and system settings that are clear and easy to read, Combustion air,m3/min.(cfm) 5.5(195) 4.6(162) even in direct sunlight or low light. Air density=1.20 kg/m3(0.075 Ibm/ft3) RDC2 Controller Features Fuel Consumption* • Membrane keypad: Natural Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz o OFF,AUTO,and RUN pushbuttons 100% 24.8 (875) 21.5 (759) o Select and arrow buttons for access to system 75% 20.3 (717) 17.6 (622) configuration and adjustment menus 50% 14.5 (512) 12.6 (444) . LED indicators for OFF,AUTO,and RUN modes 25% 8.7 (307) 7.5 (266) * LED indicators for utility power and generator set source LP Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz availability and ATS position (Model RXT transfer switch 100% 9.3 (329) 8.1 (285) required) 75% 6.5 (231) 7.1 (251) 50% 4.9 (172) 4.2 (149) • LCD screen: 25% 3.1 (110) 2.7 (95) o Two lines x 16 characters per line 1: Nominal Fuel Rating: Natural gas,37 MJ/m3(1000 Btu/ft3) o Backlit display with adjustable contrast for excellent LP Vapor,93 MJ/m3(2500 BtuM3) visibility in all lighting conditions LP vapor conversion factors: • Scrolling system status display 8.58 ft.3=1 lb. o Generator set status 0.535 m3=1 kg. o Voltage and frequency 36.39 ft.3=1 gal. o Engine temperature o Oil pressure Sound Enclosure Features o Battery voltage • Sound-attenuating enclosure uses acoustic insulation that o Engine runtime hours meets UL 94 HF1 flammability classification and repels • Date and time displays moisture absorption. • Smart engine cooldown senses engine temperature • Internally mounted critical silencer. • Digital isochronous governor to maintain steady-state speed • Skid-mounted,aluminum construction with two removable at all loads access panels. • Digital voltage regulation: ±1.0% RMS no-load to full-load • Scratch-and corrosion-resistant Kohler@ cashmere • Automatic start with programmed cranking cycle powder-baked finish. • Programmable exerciser can be set to start automatically on Sound Data any future day and time,and to run every week or every two weeks Model 48RCLC sound levels are 62 dB(A)during weekly engine • Exercise modes exercise and 63 dB(A) during normal operation. o Unloaded exercise with complete system diagnostics All sound levels are measured at a distance of 23 ft. (7 m)from o Unloaded full-speed exercise the generator set. Actual sound levels may vary based on o Loaded full-speed exercise(Model RXT ATS required) installation parameters. • Front-access mini USB connector for SiteTech- connection • Integral Ethernet connector for Kohler@ OnCueO Plus • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-306 (48RCLC) 6/21 KOHL KOHLER.). Phone 9 CO.,Kohler,Wisconsin 9-16 4 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Additional RDC2 Controller Features Available Options(continued) • Diagnostic messages Enclosure Option o Displays diagnostic messages for the engine,generator, ❑ 291 kph(181 mph)wind load rated enclosure Model RXT transfer switch, programmable interface Starting Aids§ module(PIM),and load shed kit ❑ Block Heater,120 V o Over 70 diagnostic messages can be displayed ❑ Block Heater,240 V • Maintenance reminders § Recommended for ambient temperatures below 0°C(32°F) • System settings Controller Accessories o System voltage,frequency,and phase ❑ Lockable Emergency Stop(lockout/tagout) o Voltage adjustment ❑ Programmable Interface Module(PIM) o Measurement system, English or metric (provides 2 digital inputs and 6 relay outputs) • ATS status (Model RXT ATS required) Automatic Transfer Switches and Accessories o Source availability ❑ Model RXT Automatic Transfer Switch o ATS position (normal/utility or emergency/generator) ❑ Model RXT Automatic Transfer Switch with combined interface/ o Source voltage and frequency load management board • ATS control (Model RXT ATS required) ❑ Model RDT Automatic Transfer Switch o Source voltage and frequency settings ❑ Load shed kit for RDT or RXT ❑ Power relay modules(use up to 4 relay modules for o Engine start time delay each load management device) o Transfer time delays ❑ Other Kohler®ATS o Fixed pickup and dropout settings Miscellaneous o Voltage calibration ❑ Rated Power Factor Testing • Programmable Interface Module(PIM)status displays ❑ Maintenance kit(includes air filter,oil,oil filter,and spark plugs) o Input status(active/inactive) Literature o Output status (active/inactive) ❑ General Maintenance Literature Kit • Load control.menus ❑ Overhaul Literature Kit o Load status ❑ Production Literature Kit o Test function l Warranty Generator Set Standard Features ❑ Extended 5-Year/2000 Hour Comprehensive Limited Warranty ❑ Extended 10-Year/2000 Hour Comprehensive Limited Warranty • Aluminum sound enclosure with enclosed silencer • Battery rack and cables Dimensions and.Weights • WL/UL 2200 listed,CSA certified Overall Size,L x W x H,mm(in.): 2280 x 836 x 1182 • Electronic, isochronous governor (89.8 x 32.9 x 46.5) • Engine-generator set is designed and manufactured in Shipping Weight,wet,kg(lb.): 767(1690) facilities certified to ISO:9001. Weight includes generator set with engine fluids and 407BX alternator, • Flexible fuel line sound enclosure,and silencer. • Gas fuel system(includes fuel mixer,electronic secondary gas regulator,two gas solenoid valves,and flexible fuel line between the engine and the skid-mounted fuel system components) H • GFCI service outlet(120/240 V)for customer connections • Integral vibration isolation • Line circuit breaker • NEC prime mover shutdown switch L --� • Oil drain extension NOTE:This drawing is provided for reference only and should not be • OnCue@ Plus Generator Management System for remote used for planning installation. Contact your local distributor for more monitoring (see specification sheet G6-140) detailed information. • Operation and installation literature DISTRIBUTED BY: • RDC2 controller with built-in battery charger • Standard 5-year/2000-hour limited warranty Available Options Electrical System ❑ Battery ❑ Battery Heater ❑ OnCue8 Plus Wireless Radio Kit ©2021 Kohler Co.All rights reserved. G4-306 (48RCLC) 6/21