Loading...
HomeMy WebLinkAbout50044-Z �o�OS�FF°t'�cpGy Town of Southold .3/30/2024 0 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45083 Date: 3/30/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 4832 Youngs Ave, Southold SCTM#: 473889 Sec/Block/Lot: 55.-2-8.15 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/3/2023 pursuant to which Building Permit No. 50044 dated 11/20/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Nuzzi,Christopher&Sandra , of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50044 2/28/2024 PLUMBERS CERTIFICATION DATED VA zed i ature S�FFot� TOWN OF SOUTHOLD BUILDING DEPARTMENT y• x . TOWN CLERK'S OFFICE • SOUTHOLD, NY y�ol , goo BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50044 Date: 11/20/2023 Permission is hereby granted to: Nuzzi; Christopher 60 Lilac Rd Westhampton Beach, NY 11978 To: install generator as applied for. Maintain minimum 25' setbacks from lot lines. At premises located at: 4832 Youngs Ave, Southold SCTM #473889 Sec/Block/Lot# 55,2-8.15 Pursuant to application dated 11/3/2023 and approved by the Building Inspector. To expire on 5/21/2025. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector OF SO!/T�QI . � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q ,�. • �o sean.devlinCaPtown.southold.ny.us Southold,NY 11971-0959 cDUNTY,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Christopher Nuzzi Address: 4832 Youngs Ave city:Southold st: NY zip: 11971 Building Permit#: 50044 section: 55 Block: 2 Lot: 8.15 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Atlas Electric License No: 60575ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall.Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO' Transfer Switch 300A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 24kW Generac Generator w/ 300A Whole House Transfer Switch Notes: Generator Inspector Signature: , — Date: February 28, 2024 S.Devlin-Cert Electrical Compliance Form OF SOUTyO� # # TOWN OF SOUTHOLD BUILDING DEPT. couto, 631-765-1802 +4 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 6 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �- Y A r��rYJ DATE INSPECTOR hO��OF SOUIyOIo 50-14 iq * 'TOWN OF SOUTHO.LD BUILDING DEPT. "you 1 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [. ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION' [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) [. ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: DATE 'M INSPECTOR SOUK°� # TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL T'� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: OM4 on DATE INSPECTO MELD INSPECTION REPORT DATE COMMENTS R ro FOUNDATION (1ST) -- � --------------------------------- _ � C FOUNDATION (2ND) z � 0 ROUGH FRAMING& ..3 PLUMBING S r INSULATION PER N.Y. STATE ENERGY CODE �. Ate FINAL 3 ADDITIONAL CO MENTS C�Z — �rn � rn k 9J ro N o z x x - o ro =�o�Og�FFOIK�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 hltps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT iJ c�` Ej LiV�' 1 F r Office Use Only / 66 PERMIT NO. Building Inspector: NOV 3 2023 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,'an �R'ITIME?G V FT. Owner's Authorization form(Page 2)shall be completed. Date: 1�3 f X-3 OWNER(S)OF PROPERTY: Name: _..__ ?"�__.__.__....._____`_ SCTM#1000 Project Address: Phone#: Email: Mailing Address: .:CONTACT PERSON: Name: Mailing Address: Phone#: Email: DESIGN PROFESSIONAL INFORMATION:- Nam)e: Mailing Address: ` Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED.CONSTRUCTION-, ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: C�Other &" $ Will the lot be re-graded? ❑Yes ONO Will excess fill be removed from premises? ❑Yes ❑No 1 - I f 7 PROPERTY INFORMATION Existing use of property: Intended use of property: tqtqrW-t _ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as'herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. I Application Submitted By( rin e): �� �j JZ..Z` ❑Authorized Agent BfOwner Signature of Applicant: Date: _U—Q.Zk --- CONNIE D. BUNCH Notary Public,State of New York STATE OF NEW YORK) No. 01BU6185050 SS: Qualified in Suffolk County COUNTY OF Commission Expires April 14,2��) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this _ t 6U-Aday of MOV�,M, , 20� CA Notary Public r PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 PVT Southold, New York 11971-0959` Telephone (631) 765-1802 - FAX (631) 765-9502 ' rogerr(cb-southoldtownny.gov — sea nd(absoutholdtownny.gov APPLICATION' FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 11131;L3 Company Name: 6r--c1&tL Electrician's Name: License No.: Elec. email: Elec. Phone No: L request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: r�&-L\ Address: q 13 2- i NLT5 fii cry Cross Street: Phone No.: o BIdg.Permit#: email: Tax Map District: 1000 Section: � Block: '-- Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underg round❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? D Y N Additional Information: PAYMENT DUE WITH APPLICATION 1 SCDHS ID NO. R-21-1466 SURVEY OF PROPERTY A T SOUTHOLD ai + .�;.wRVICES AP PR O�°�_�L Cc: CONJ I'f UC' , :35 a, t4, rOR TOWN OF SOUTHOLD SUFFOLK COUNTY, N. Y. - �� 1000-55-02-815 Date: �E�_� � Ks. Ref, ���. ���- '��r�s� SCALE: 1'=30 The sewage al this'uca pan have been NOVEMBER 18, 2020 inspected t:trfd,/or cl--. by?.. ;P "e,:;: .r, {,r I,or other,--,encies and DECEMBER 3, 2020 (CER7IFICA77ON ADDED) found to be sais6cwrw K R A;MAXi`OUM Or KDROOMIS TOTAL DECEMBER 14, 2020 (REVISIONS) � s��a�e?, A'`�* ^�> • MAY 2, 2021 (PROPOSED/ SI TE PLAN) MAY 14, 2021 revlslons) _ C RA}`' K N E t'P`R° �`°='° C `i�I� JUNE 28, 2021 REVISIONS) 0FFICE 0 Wit5 `L A(JFR4ENT _.��_. ._____- q NOVEMBER 15, 2022 STAKE OUT ?ECAST SEP TIC TAl1�ff ' _`F t�`` JAN. 3, 2023 (F7VD7)0N LOC.) RETE LEACHING RINGS JANUARY 4, 2024 (FINAL SURVEY) FEB. 2, 2024 (REVISION) 1 FEB. 14, 2024 (REVISIONS) 3' 25' RIGHT OF WAY TO INCORPORATE WATER 59 . SGVEGLIA LINE AND OTHER UTILITY EASEMENTS 00 AE0EO E� CI_.EL. i WELL 150• ` E 4c).5' •20 R=25.00" / S77.30 e� O L-39.27' E/CL.EL �` EL. 41.0. 0 R=25A0' — � E �-� x x � L=39.27' 41.6 N77•30 20 SPUN RA, E CS m TELE.COM. 0- in. I (VAULT J t cl. x ELECT. FENCE _9 1p 4 METER oa GENERATOR 0 S�T:J0 20 �+ O' SUBDIVISION TEsrHOLE �rl E 10'mi. D.W. \ \[][� 25.E NUMBER 2 TRANS. x ELEVATION= 40.5• t Gl- 10 x�/ UIG FUEL E) LPl / TMJK � � �m � LPz ST WALK WNDW AC MEU. \ UNITS G Q \ O C O w 4 �1 COVERED Wo 21. O- 120 Q AC QN 0 SHONE PORCH 11. O- OUNITS f � g ��� A 60• to < 60 in I toor N, ` s FRAME I y0U 5' o x 01 R.EC q3• 120 p O On A32 O BRICK 31`� PAN10 W N I60 U nd• FI • tr. x WWELL ECK GAM PORCHIPA�O f0.6e- x GANE STONE LOT 4 DRIVEWAY 0� `^ N SHONE W�K DW y:J VACANT fff•���iii Z a rn ( , A 1:I C/0 10'� � <� 5v> I-O�� 3g9 35� 5C cl T`; STONE WALK A -.O �r. WOODEN ` N1+' O COPING STNE — � f REBAR � PRIVACY — � FENCE1 la .3 O POOL EQP. ON CONC. SLAB G tiJ � O DW A z G T O rnNp rn �G JG WELL 150'+ N rn z LOT 1 c,+ 6 Iko RAMP S SHED WELL Q (WELL FOR HOUSE IRRIGATION ONLY) pD � 1 FELOR E1- xFENCES GAME 0.2`1'1 37 9 j x N x 0 2y X� ®�"NE tv 1r f SHED G�X�1 �J A��E 1X F REBAR xl PSN &� E 1.06, ®K� I �, a` s..J_ x OPEN HICKE i' DEER FENCE '-:, E� �.5q.'00 O�F Ppgp, 0 y '=„ 30 3 S.7 N� INCOR G .x� 00 '(FtV os193��° FE.c•oR' PEOpN1C VAO� At o•2E' N.YS LIC. N. 01�_ .YS LIC. NO. 0! PECONIC SUR ORS, P.C. (631) 765-5020 FAX (631) 765-1792 Suffolk county Dept.of Labor,Licensing✓&Consumer Affairs Si oVEMFIIIT LICENSE Ho IN+FR Name ROBERT HA'!ES Business Name his certifies that the V•lalpole outdoors LLC nearer is duly licensed Dy,re County 'of suifol License Number:}{1-635=1 061/112020 Rosalie Drago Issued: 0510112024 Commissioner Expires: <11ERK Workers' CERTIFICATE OF T��E C®ap B®aidensatlon NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1 a.Legal Name&Address of Insured (use street address only) 1 b.Business Telephone Number of Insured WALPOLE HOLDINGS,LLC WALPOLE OUTDOORS,LLC 508-921-4941 255 PATRIOT PLACE FOXBOROUGH,MA 02035 1 c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 47-2556626 2. Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) THE NORTH RIVER INSURANCE COMPANY Chris Nuzzi 4832 Youngs Ave 3b.Policy Number of Entity Listed in Box"I a" Southold,NY 11971 408-743973-9 3c. Policy effective period 10/15/22 to 10/15/23 3d.The Proprietor,Partners or Executive Officers are included.(Only check box if all partners/officers included) Q all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: KIMBERLY RYAN (Print name of authorized representative or licensed agent of insurance carrier) 5Ci/nber(L�yan Approved by: kimberly rvanaacfins com 04/18/2023 (Signature) (Date) Title: EXECUTIVE UNDERWRITER Telephone Number of authorized representative or licensed agent of insurance carrier: 972-380-3187 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov Doc ID: 20230418082242992 Sertifi Electronic Signature 7 ® DATE(MMIDD/YYYY) A��o CERTIFICATE OF LIABILITY INSURANCE 4/18/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTAPRODUCER NAME: Claire Purser Marsh&McLennan Agency LLC PHONE 972-770-1401 aC No E-MAIL 8144 Walnut Hill Lane, 16th Floor arc Ext Dallas TX 75231 L ADDRESS: Claire. urser marshmma.com INSURERS AFFORDING COVERAGE NAIC# INSURER A:North River Insurance Company 21105 INSURED WALPOHOLDI INSURER B:United States Fire Insurance Company 21113 Walpole Outdoors, LLC 255 Patriot Place INSURER C Foxborough MA 02035 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:107652606 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER MMIDDPOLICY EFF MPIM[DD EXP LIMITS LTR IN D WVD A X COMMERCIAL GENERAL LIABILITY 5432316336 10/15/2022 10/15/2023 EACH OCCURRENCE $1,000,000 D GE CLAIMS-MADE OCCUR FxlPREM SESOEa occurrence $300,000 MED EXP(Any one person) $15,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY jE O LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: B AUTOMOBILE LIABILITY 1337530725 10l15/2022 10/15/2023 COMBINED SINGLE LIMIT g 1,000,000 Ea accident X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS PROPERTY DAMAGE HIRED NON-OWNED $ AUTOS ONLY AUTOS ONLY Per accident A X UMBRELLA LIAB 1 X OCCUR 5821198704 10/15/2022 10/15/2023 EACH OCCURRENCE $10,000,000 EXCESS LIAR CLAIMS-MADE AGGREGATE $10,000,000 DED I I RETENTION$ $ A WORKERS COMPENSATION 4087439739 10/15/2022 10/15/2023 X STATUTE PER OERH_ AND EMPLOYERS'LIABILITY Y/N ANYPROPRIETOR/PARTNER/EXECUTIVE � NIA E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under E.L.DISEASE-POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS below DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached if more space is required) Additional Insured form#FM101.0.1848 edition 05/11 applies to the General Liability policy. Waiver of subrogation form#FM101.0.1206 edition 01/11 applies to the General Liability policy. .Primary&Non-Contributory form#FM101:0.1848 edition 05/11 applies to the General Liability policy. Additional Insured form#FM114.0.1378 edition 11/11 applies to the Automobile Liability policy. Waiver of subrogation form#FM114.0.1378 edition 11/11 applies to the Automobile Liability policy. Waiver of subrogation form#WC000313 edition 04/84 applies to the Workers Compensation policy. See Attached... CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Chris Nuzzi 4832 Youngs Ave AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD THIS CERTIFICATE SUPERSEDES PREVIOUSLY ISSUED CERTIFICATE AGENCY CUSTOMER ID: WALPOHOLDI LOC#: �►�� ADDITIONAL REMARKS SCHEDULE Page 1 of 1 AGENCY NAMED INSURED Marsh&McLennan Agency LLC Walpole Outdoors,LLC 255 Patriot Place POLICY NUMBER Foxborough MA 02035 CARRIER NAIC CODE EFFECTIVE DATE: ADDITIONAL REMARKS THIS ADDITIONAL REMARKS FORM IS A SCHEDULE TO ACORD FORM, FORM NUMBER: 25 FORM TITLE: CERTIFICATE OF LIABILITY INSURANCE The General Liability policy includes a blanket additional insured endorsement to the certificate holder only when there is a written contract between the named insured and the certificate holder that requires such status. The General Liability policy contains a blanket waiver of subrogation endorsement that may apply only when there is a written contract between the named insured and the certificate holder that requires such wording. The General Liability policy contains a Primary and Non-Contributory endorsement that may apply only when there is a written contract between the named insured and the certificate holder that requires such wording. The Automobile Liability policy contains language that provides additional insured status to the certificate holder only when there is a written contract between the named insured and the certificate holder that requires such status. The Automobile liability policy includes waiver of subrogation wording that may apply only when there is a written contract between the named insured and the certificate holder that requires such wording. The Workers Compensation policy includes a waiver of subrogation endorsement that may apply only when there is a written contract between the named insured and the certificate holder that requires such wording. Excess Liability is follow form pursuant to form#FM101.0.302 and 08/18 edition date ACORD 101 (2008/01) ©2008 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD NEw I Workers' CERTIFICATE OF INSURANCE COVERAGE PORK STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1 a. Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured WALPOLE OUTDOORS, LLC 781-349-4911 255 PATRIOT PLACE FOXBOROUGH, MA 02035 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured (Only required if coverage is specifically limited to certain locaffons in New York State,i.e.,Wrap-Up Policy) 472556626 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Chris Nuzzi 3b.Policy Number of Entity Listed in Box"1 a" 4832 Youngs Ave DBL572986 Southold, NY 11971 3c.Policy effective period 01/01/2023 to 12/31/2023 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: n A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employers employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Signed Date Si 4/18/2023 By WA0, j g (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer IMPORTANT: if Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier, this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B, 4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board (only if Box 4B,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers' Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed BY (Slgnalute orAulhui iced NYS workers'Compensation Board rmploycc) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 111°°°1°°11°°1°111111°!1°1!°!'°1IIIIIII APP 0 ED AS NOTED 01� 3 B.P.# i PEE 3 BY: NOTIFY BUILDING DEPARTMENT AT 631 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TR'A10 RE01 ITIRED FOR POURED,0NCRF" 2. ROUGH-FRAMING & INSULATION 4. FINAL-CONSTRUCTION 1',AUST BE COMPLETE FOR.C.O. ALL CONSTRUCTION SHALL MEET THE REQUfflEMENTS OF THE CODES OF NEW �- YORK STATE. NOT RESPONSIBLE FOR DESM OIt Cot lnuc olm E w4ms or COMPLY WITH ALL CODES OF !� ���es NEW YORK STATE &TOWN CODES AS REQUIRED AND CONDITION F SOUTHOLD TOWN ZB SOUTHOLD TOW NNING BOARD S0UTH0LD N TRUSTEES N,YS. S OLD HPC HD OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICAT OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED GENERAC® GUARDIAN® SERIES 26 kW Residential Standby Generators ONES- Air-Cooled Gas Engine Standby Power Rating INCLUDES: G007290-0,G007291-0(Aluminum-Bisque)-26 kvV 60 Hz • True Power'" Electrical Technology • Two-line multilingual digital LCD Evolution"controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available ��� • Electronic governor • Standard Wi-Fi°connectivity ' • System status&maintenance interval LED indicators • Soundlattenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation GENERAC • 5 Year limited warranty • Base fascia • Listed and labeled for installation as close as 18 in(457 mm)to a .- structure." 'Must be located away'from doors,windows,and fresh air intakes and in ON or C V� US QUf M1accordance with local codes. c uS LISTED Note:CErL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are EfL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- C SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER'"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave C SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MGi-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK*CONNECTIVITY:FREE with select Guardian Series Home standby generators,Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. LuNERAC A OMISE ®@09 _ ' NbPM1USAaWNmRutlMW[ GENERAC® 26 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution"' Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM'-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. 1 GENERAC® 26 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for ' complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. i GENERAC® 26 W Specifications Generator Model G007290-0 G007291-0 (26 Rated6,OOQ WW,,,- -mRfmu�n c e(.ca 1 egw� Rated maximum continuous power capacity(NG) 22,500 Watts* V Rated maximum continuous load current—240 volts(LP/NG) 108.3/93.8 S fl: Main line circuit breaker 110 amp J Number of rotor poles 2 60 It Mated Xte*&YLL Power factor 1.0 xm*50 CCA mm]tWdr Gm-'u' a5AGM*6WWAi6ffi Unit weight(lb kg) 51235 Z A 8/2 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load** 67 Ise in Quloihsrilk6i mode* Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Nanirber of nders� Displacement 999 cc Valve arrangement Overhead valve wwwr Governor system Electronic Starter 12 VDC filter 7777777- 1�71 QUIA Operating rpm 3,600 0 aral #Yhr:60*4 1/2 Loa 333. 43 Full:LoaY. d' Yquicl'p ro*e 75(2.0 Loid' 4 N-ote:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas. For BTU content,multiply fO/hr x 2500(LP)or 0 hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or ml/hr x 37.26,(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. _iW oh u@ M=L= TO;': 77Ki—tomatri Y7:b�� Weelkl MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. StepsPower Is unit. Ready to Run/Maintenance messages Standard _7P d Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) P4 Future Set Capable Exerciser/Exercise Set Error warning Standard 777777'77 0 7 eve Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration.). 7 P9 Smart Battery Charger Standard CtrarpoFaultfA#ssing AC7,�7­7.7. 'Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard t M—YoW i Le R L—Raid-5 9 Under-Frequency/Overload/Stepper Overcurrent Protection Standard 10a illit use6l use Problem Pi 777 s, Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard M-7--7 411'' ri 72 HzYrpm'Serfse.Lbss Shutdown 2 7 High Engine Temperature Shutdown Standard Iterw Faultill.,uoneotw too, Common external fault capability Standard Mettilirk6dwe1firlwate Rating definitions—Optional Standby:Applicable for supplying backup power forthe duration of the utility power outage with correct maintenance performed. *No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046,UL2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level and approximately 1% for each 10 OF(6 DC)above 60 OF(16 OC).**Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. U.S.EPA certified for non-emergency applications. GENERAC® 26 kW Switch Options Service Rated Automatic Transfer Switch Features Model 6007291-0 26 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. Current rating(amps) 200 • U to eight additional large 240 VAC loads can be managed when used in conjunction 120240 10 P 9 9 ( ) 9 1 VoHa rat( `fV with Smart Management Modules(SMMs). �"� Utility voltage monitor(fixed)' • Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80% -Dropout 65% • Main breakers are rated for 80%continuous load. Rediuit"to Utii' emu' A 19 sec • 2-pole,250 VAC contactors. EFL or UL listed Standard • Service equipment rated,dual coil design. Kefo "10 A1t1L33tt Circuit breaker protected 22,000 • Rated for both aluminum and copper conductors. gug:iaa • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEM/VUL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly —w, Dimensions = n, 200 Amps 120/240,to Open Transition Service Rated ;" Height Width H1 H2 W1 W2 5 Depth ;_ w H, in 26.8 30.1 10.5 13.5. 6.9 a cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges " Conductor Lug Neutral Lug Ground Lug 250 MGM-#6 350 MGM-#6 2/0-#14 GENERAC® 26 kW Available Accessories R 11!11110'0 U =esPfflpfi6nr,1 G0071 01-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(-18 IC). (Not nec- essary for use with AGM-style batteries). Oil Warm r -18 oC). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0 IF 60071 0�-1 Breather-Warmer Breather warmeris foruse in extreme cold weather applications.For use with Evolution controllers only in climates where" ' heavy icing occurs. G005621-0 Auxiliary'Transfer Switch The-auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pro-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's Scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tanles fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. 13007006-b(5oamp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. --- G007169-0-4G LTE Mobile DO Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-Fi/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealerfor fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs 037. 1218.- Model 14 1�] UP [25.1 in) 8.0 G007290-0 696471087307 G007291-0 696471087314 0 999�� 727.2.. 90�� [28.6 1 oil 0 0 WOMEM= [25.51n] LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. - S45 W29290 HWY.59,Waukesha,WI 53189 - generac-corn N @2022 Generac Power Systems,Inc. All rights reserved. All specifications are subject to change without notice. Part No.A0002026894 Rev.0 04/26/2022 GENERAL® 26 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi'equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for ' complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. J GENERAC® 26 kW Specifications Generator Model G007290-0 G007291-0 (26 kW) Rated maximdraordimious c er ca i P) a 4:pa _ � .28,000Watts". Rated maximum continuous power capacity(NG) 22,500 Watts" Rated ta2d#i�•. Rated maximum continuous load current-240 volts(LP/NG) 108.3/93.8 ' Total:Harinbnic'Distoitirtn: s . ::,: Lessthan'S%- Main line circuit breaker 110 amp Phase'• 1:,-,: Number of rotor poles 2 Ra#etl'AC:he'ency:;.; : • ..:. .... .. . ..:. . ..:. '.. .:.. ,= .. .=': .".. - :X :fi.' Ot+i;. Power factor 1.0 Battery ra ireri►ent,(not bieluded). =:-."`, i2Yoits,.GrouP 26R 540 CCA midlmtim_ up�35AGM:650.CCAmfnhnuin n ..t Unit weight(lb/kg) 518/235 f)imensio sl(Lz,W;x•N t#nkcrri. { 48z25x29/a21'.9ir63.5'x.7.3:7,;> + ; u;.''; > Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load** 67 5ound.on 'ut in d8{A,at 23.tt p m'with generator in QuQuiet-Test`"low-speed exercise mode— Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Numlrerfnders. _ .. _ '�e`2>,.H r,3�+.:'#>,3•;._ Displacement 999 cc inderblack��,,: .. - Alurninuni -cast;iroa sleeve` �: '• =�*��`��_::�:�`` Valve arrangement Overhead valve id sta#evUmagnata __� tgrtilansyst Sol am -- Govemorsystem Electronic - Starter 12 VDC Oita c ine_lud_ing Frtter77 7 7_ Ap cox :9. 11.8 L=: Operating rpm 3,600 - ,1 - ,... ,�,.• �h:�.". �.k tdatui4'�gas ' 1/2 lo2d _ <t�(5.32), Full Load. 333(9.43) Llqutd propaiLe: ''` it3/hr(0/hr)(A-/1 75(2:06).(7:7,ijs I,` :132=(3:63)tt3.13]. Note:Fuel pipe must be sized for full load.Required fuel pressure to generatorfuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2,49-2.99 kPa)for LP gas, For BTU content,multiply fta/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. fsalode_bU#!o� t) .•' r:; ''-':-: -Au-to-m-alic start on utility faiW4;.tMeekly.Bi-iaaekiy;or Montiriy,sel le exefcrser- ``- MANUAL Start with starter control,unit stays on.If utility tails,transfer to load takes place. :OFF., ..'. _ — � � ps unl,.Powei is removed.Gontrdl:and ehaer I er a.; Ready to Run/Maintenance messages Standard Engine furi;hours indication c Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Util' VaHa Loss eturii to:US_ ad�r�table(brovmord s_eit_(n_ From if,V 1! 90'=2f 6 V;R=•- ;::�x Future Set Capable Exerciser/Exercise Set Error warning Standard �Run{A1arrtUMaiidenadce'loy ;` - s. Sflaveidseach Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). tStarti aldck-out:.' Starter carural re-en" e untiL5 see after:_engine_has sidpped Smart Battery Charger Standard CttatgecFaiilf/Missrng AG,vrar L 3 - :Standard�: -•*�= - �. Low Battery/Battery Problem Protection and Battery Condition indication Standard Au#omatic Vattagi Regir Won with Over and Under Votka a P,my faction . Standard -- Under-Frequency/Overload/Stepper Overcurrent Protection Standard 5af Fusedrs a ProblamProtection "Stan�rd Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard (Ouercrankloverspeer @ 72 Whom Sense Loss Shutdown --- - _--Staadaid': ti High Engine Temperature Shutdown Standard fntamal;FaultaiioomectWhing;xotectlon Y Standard Common external fault capability Standard Field:upgradable•Nrmwara 3 r-' -.,Standard. -- Rating definitions-Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. 'No overload capability is available for this rating.(All ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1.000 ft(304.8 m)above sea level and approximately 1% for each 10 IF(6°C)above 60 IF(16 IC)."'Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. U.S.EPA certified for non-emergency applications. GENERAC® 26 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007291-0 26 kW • Intelligently manages up to four air conditioner loads with no additional hardware. No'of oars 2 Current rating(amps) 200 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction VoNaye aNA�) 12fy2y2�40 1 with Smart Management Modules(SMMs). Utility voltage monitor(fixed)* • Electrically operated,mechanically-held contacts for fast,clean connections. -Dropout80 % • Main breakers are rated for 80%continuous load. Rum fo Utfli - 0§06§WA 18 sec • 2-pole,250 VAC contactors. ETL or UL listed Standard • Service equipment rated,dual coil design. Enclosure t KEMIWt 3R • Rated for both aluminum and copper conductors. Circuit breaker protected 22,000 Lu �rarafe ... _�• 2fr0;NICN1-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly I—w1 Dimensions 200 Amps 120/240,1a Open Transition Service Rated Height Width Depth H1 H2 W1 W2 to Ni in 26.8 30.1 10.5 13.5 6.9 IDEM cm 67.95 76.43 26.67 34.18Wire RangesConductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 GENERACO 26 kW Available Accessories Model# Praduet . scrip#ion"ri��.����' �'�.�' � ..��,�;,: � ;�.,,��..��I�,4� .• .. G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C). (Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. ' G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G0071 69-0-4G LTE Mobile Link Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-FV Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit 113ase plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC 6[25.1In) i480�; G007290-0 696471087307 G007291-0 696471087314 727.2 mm [28.8 Inj to a o 10 648 mm 1232 mm [25.5 In] [48.61n1 LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for elact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2022 Generac Power Systems,Inc. All rights reserved. All specifications are subject to change without notice. Part No.A0002026894 Rev.0 04/26/2022