Loading...
HomeMy WebLinkAbout48413-Z ��o�gUEFQ(,�coGy Town of Southold 4/24/2024 0 P.O.Box 1179 o _ 53095 Main Rd Southold,New York 11971 col � ya CERTIFICATE OF OCCUPANCY No: 45140 Date: 4/24/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2890 Kerwin Blvd., Greenport SCTM#: 473889 Sec/Block/Lot: 53.4-44.11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/l/2022 pursuant to which Building Permit No. 48413 dated 10/17/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Salzberg,Fred&Dorothea of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48413 1/9/2023 PLUMBERS CERTIFICATION DATED Author`ed gnature �oSueFa` �� TOWN OF SOUTHOLD may BUILDING DEPARTMENT C." TOWN CLERK'S OFFICE 101 �� SOUTHOLD, NY col Sao BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48413 Date: 10/17/2022 Permission is hereby granted to: Salzberg, Fred 2890 Kerwin Blvd Greenport, NY 119442745 To: Install roof mounted solar panels to an existing single family dwelling as applied for. At premises located at: 2890 Kerwin Blvd., Greenport SCTM #473889 Sec/Block/Lot# 53.-4-44.11 Pursuant to application dated 9/1/2022 and approved by the Building Inspector. To expire on 4/17/2024. Fees: SOLAR PANELS $50.00 CERTIFICATE OF OCCUPANCY $50.00 ELECTRIC $100.00 Total: $200.00 rv- Building Inspector OF SO�T'fOl � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.deviin(a)-town.southold.ny.us Southold,NY 11971-0959 Q�ycOUNT`I,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Fred Salzberg Address: 2890 Kerwin Blvd city:Greenport st: NY zip: 11944 Building Permit#: 48413 Section: 53 Block: 4 Lot: 44.11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Long Island Power Solutions. License No: 36178ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch .UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 9.87kW Roof Mounted PV Solar Energy System w/ (25) REC395AA Pure Modules, 40A Fused Disconnect, IQ4 Combiner 220x2 215x1 Notes: Solar Inspector Signature: Date: January 9, 2023 S.Devlin-Cert Electrical Compliance Form OFSOOTyo U t, Lf 13 �V TOWN OF SOUTHOLD BUILDINGiEP�T4 courm��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] .FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR �' # # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 'Sv1ge— [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION, [ ] PRE C/O [ ] RENTAL REMARKS: D / a b• DATE •off INSPECTOR Pacifico Engineering PC -- Engineering Consulting 700 Lakeland Ave,Suite 26 ® E 631-988-0000 Bohemia, NY 11716 G c olar@pau r>�intfin D August 24,2023 � , Town of Southold sEp �O'n Building Department54375 Route P.O. Box 1179 -row,G11tSuthod NY 119 SOh� ht� Subject: Solar Energy Installation for Fred&Dorothea Salzberg Section-Block-Lot: 53-4-44.11 2890 Kerwin Boulevard Permit Number: 48413 Greenport, NY 11944 S I have reviewed the solar energy system installation at the subject address on August 24,2023.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2020 Residential Code of New York State and ASCE 7-16. To my best belief and knowledge,the work in this document is accurate,conforms with the governing codes applicable at the time of submission,conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. f Regards, Ralph Pacifico, PE Professional Engineer of:N�dyr m OFEpNP� Ralph Pacif' icnal Engineer NY 066182/NJ 24GE04744306/FL 87297 t. FIELD INSPECTION REPORT DATE COMMENTS ro oom FOUNDATION(1ST) -------------------------------- co) FOUNDATION (2ND) m z �o o cn *3 ROUGH FRAMING& t PLUMBING 04 r INSULATION PER N.Y. y STATE ENERGY CODE Q FINAL ADDITIONAL C PMMENTS A 23 lc..c, r`iG 0 CP— C� X N H 0 z x d ro H jr ff.U( �OG TOWN OF.SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959, Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtomm.gov . f. . Date Received APPLICATION FOR BUILDING PERMIT LiFor Office Use Only PERMIT NO. 1�3 1 Building Inspector: SE 0-"� 2072 BUILDING DEP`f. Applications and forms must be.filled out in their entirety. Incomplete GOWN OFSOUTHOLD, applications will not be accepted. Where the Applicant is not the owner,an Owner's.Authorization form(Page,2)shall be completed. - Date:August 31 st 2022 OWNER(S)OF PROPERTY: Name:Fred Salzberg SCTM, #1000-53.4-44.11 Physical Address:2890 Kerwin Blvd, green port, NY. 11944. Phone#:631-275-2508 Email:Eastendfred@outlook.com. Mailing Address:2890 Kerwin Blvd,'Green port, NY 11944 CONTACT PERSON: Name:Sue Estabrooke/Long Island Power Solution's Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:sue long island powersolutions.com DESIGN PROFESSIONAL INFORMATION: Name:Pacifico Engineering, RIC ' Mailing Address:700 Lakeland AVenue, Suite.213 Phone#:631-275-2508 Email:Eastendfred@outlook.com CONTRACTOR INFORMATION: Name:Michael Catizone/Long Island Power Solutions Mailing Address:2060Ocean Ave., Ronkonkoma, NY 1'1779 Phone#:631-348-0001 Email:mike@longislandpowersolutions.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ®Other Proposed( 25 )panel roof mounted array.. ( 9,875 )kW System $26,422.25 Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property:Single Famil Qwqll.ing Intended use of property:Single FamilyDWellin Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to - this property? Dyes ®No IF YES, PROVIDE A'COPY. B Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of.a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Catizone Electrical/Long Island Power Solutions Application Submitted By(print name BAuthorized Agent ❑Owner Signature of Applicant: Date:. a(2)1 1202.2 STATE OF NEW YORK) SS: COUNTY OF -Suffolk ) Michael Catizone being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have.performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this. I C"­day of 20 22- L 'Z- Notary Public . ESCAYLIN CRISOL RIVERA RODRIGUEZ PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC-STATE OF NEW YORK Ne. 01 R16434031 (Where the applicant is not the owner) Qualified in Suffolk County My Commission Expires 05-31-2026 residing at 2np5cs�'�Y1 Michael Catizone/Long Island Power Solutions G2=eCr r1. t 1114 do hereby authorize to apply on my behal to t To of So thold Buildi Department for approval as described herein. . io Ia2 Owner's Si a r Date Print Owne Name c� 2 1 ILDING DEPARTMENT- Electrical Inspector Q � ll. �t-�0 ;4 SSG G TOWN OF SOUTHOLD D s-! o x,oFsoown Hall Annex--54375 Main.Road - PO Box 1179. Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 . ro-qerr0southoIdtownny.gov=seand(cDsoutholdtownny.gov.; i APPLICATION FOR ELECTRICAL INSPECTION-, ELECTRICIAN INFORMATION (All Information Required) Date;_ Company Name: Catizone Electrical/Long,Island Power Solutions Name:Michael Catizone License No.: 36178-ME email: sue@longislandpowersolutions.com ! , Address: 2060 Ocean Avenue,Ronkonkoma,NY 11779 Phone No.: 631=348.0001 y JOB SITE INFORMATION (All Information Required).!� Name:Fred Salzber Address:2890 Kerwin Blvd,Green ort,-NY 1.1944. Cross Street: Pheasant Place. -- i Phone No.:. 631-275-2508 BIdg.Permit#: . email: Eastendfred@outloo k.com_. _ Tax Map District: 101110. 0 0 _Section: _53 Block: .4 _Lot:_44.11 BRIEF DESCRIPTION OF WORK (Please Print Clearly). Proposed( 25 )panel roof mounted array. a ( 9,875 )kW System, a �I Circle.All That Apply: Is job ready for inspection?.: YES / NO Rough.In Finale Do you.need a Temp Certificate?: YES / NO Issued'On i Temp Information: (All information required) Service Size 1 .Ph 3 Ph. Size: _ -_. _,_A #Meters _ __ Old-Meter# . New.Service-- Fire Reconnect=Flood Reconnect-Service Reconnected- Underground =Overhead s, # Underground Laterals. 1. 2 H Frame, Pole. Work done on Service? Y N :Additional-Information:;. Modules: (25) Rec395AA Pure. Inverters: (25) Enphase IQ-7PIus .Suagort: Iron Rid a XR100 _ ;PAYMENLQUEWITHAPPLICATION..- Request'for Inspection Formals. i i LONG ISLAND OWER2060 Ocean Ave Ronkonkoma, NY 11779 PS 4LUTIONS 631348-0001 www.longislandpowersolutions.com e TOWN OF SOUTHOLD—Building Division Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Dear Building Dept: As per your Building Department, enclosed please find the building permit application, submitted on behalf of our client/property owner: Property Owner: _ Fred Salzberg—(631).275-2508 Project/Property Address: 2890 Kerwin Blvd, Greenport,NY 11944 Section/Block/Lotc 1000-53-44-44.11 Electrician/36178-ME: Michael Catizone.—2060 Ocean Ave.,Ronkonkoma,NY 11779-(631)34.8-0001 Contractor/53562-I1: LI Power Solutions-2060 Ocean.Ave.,.Ronkonkoma,NY 11779-(631)348-0001. Architecture&Planning: Pacifico Engineering—700 Lakelalnd Ave, Ste 2B,Bohemia,NY 11716.-631=98870000 Enclosed Please find: o Application Fee: $200.00 • Permit Application • (4) Copies of the.Property Survey •. (4) Copies of the Engineering Drawings&-Specs • Liability, Disability &.Workman's Comp Insurance Certs Please send the Receipt and Permit to Long Island Power Solutions. Should you require anything further; please contact me. Sincerely, Sue Estabrooke, Permit Manager . Long Island.Power Solutions .2060 Ocean Avenue Ronkonkoma,NY.11779 Ph- 631-348-0001 Fx= 631-348-0018 sue@Gopowersolutions.com Go Green Save Green OOOj3-04,44.1 t. Y. LQT a: coi2S KERWIN BLV,.D [50'] d; ro;. n. 1 O tC�av AID' to 09 � r i :....mre.e sere:a.o•vtrtt.ov..csa.�wtr•�•.,»a.f.An�rros - .-' -'. --- - - _- - . .+ec.cw:x:s.;r'i ...:i.orvraoic«saiva.r��»v.wyo- i�Sa1h1V�t.'�.1�• LUT ai - . e.fan•:MV;a.n'NC•sN9.Go.e+�a�v-ppvl•'e M•6iy .. � - ""'°"'""^"°"""m°°owl-*""' MO AUGUST,A' 'RES SECTION'? . �...._. {nKw1�'goY.aw6�0U��Sar3®Yt1N\fU Yrn v.ril{K +� ���•• a.•.x...,. . . ARtHAMOMAQUE-TdAIN OF SOUTHOCD,';��sanwi�aw+. .)►w.r�.v6t�er�sa+gaoiadaQe.i••i.. - - - - - . �'. es'.°nwc ".n°:ew•a.•.x°°°^n°°tnrc'e•"r�c.a. SUFFOLK COUNTY,NEW YCRK e4`��•e�.ae COnO C19Ryj Yeef 4Ca7A+R9 t�y�i Y,y y6�: "'� .• � . n�swsMa.rova.a�•avoo.w��,wonrv�es�• wv•w' SURVEY OATE:. 0�/19/07'. . . SCALE', 0 Pos�a.rcocorosrRuc*wN: * DWIN G,GRAO` : LAND.SURVEYOR 78 Vtil0"a*r Road .Ro*yPoim.N:Y" 11.ln- 6�64 l-344Z Suffolk County P6pt of Labor,Licensing,&-Consumer Affbirs HOME IMPROVEMENT LICENSE Name MICHAEL J CATIZONE Business Name This G&Oliobatlh'e LONG ISLAND I POWER SOLUTIONS INC �66ir&is duly licensed 3y ttje,Co6hty 4'suffbik License Number.H-53562 Rosallle,Drago- Issued: 0SID6120.14 0owhisslarfer Expires; 06/01/2024 S Offolk rl&u nw..De It-,'of "boi.Li"nsing, Affairs nsumer AOL U�CEWZ VASTER klICHAEL dATIZONS Busina.s.S.-Naf#g LON�_ISLAND Pti+%T�RSOWTIONS fwb 0gi pi Lltens"e Number:M153-q60, Rosalie Ii��� Issued: o6J0st2oia E*pIres- 0610 V=4 & Aifgok•cjaimtv WWI,LiZrj: , UM LUCK AA J C.AIZONB .twafw d4z"'rod rcat0o't Inc Client#:83176 CATIELE DATE(MM/DD/YYYY) ACORD. CERTIFICATE OF LIABILITY INSURANCE 6/27/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Commercial Support Edgewood Partners Ins.Center PHONE - A/C No Ext: A/C No): 40 Marcus Drive E-MAIL RESS: NECertificates@epicbrokers.com 3rd Floor INSURER(S)AFFORDING COVERAGE NAIC# Melville,NY 11747-2647 INSURER A:Utica Mutual Insurance Company 25976 INSURED INSURER B: Catizone Electrical Inc INSURER C: 2060 Ocean Avenue INSURER D Ronkonkoma,NY 11779 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDLSUBR POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER MM/DD MWDD A X COMMERCIAL GENERAL LIABILITY X CPP4784747 7/01/2022 07/01/2023 pEAACCHgOCCURRENCE $1 OOOOOO CLAIMS-MADE D OCCUR PREMISES Eaoccurrence $100 OOO MED EXP(Any one person) $10 000 PERSONAL 6 ADV INJURY $1 000 000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 —1 PRO- X POLICY ECT F LOC [PRODUCTS-COMP/OP AGG $2,000 000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ A WORKERS COMPENSATION 4766763 7/01/2022 07/01/202 X PERATU OTH- AND EMPLOYERS'LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N E.L.EACH ACCIDENT $500 000 OFFICERIMEMBER EXCLUDED? � N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $500 000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT 1$500.000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Town of Southold is included as additional insured for general liability coverage as required by written contract. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold, NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016103) 1 of 1 The ACORD name and logo are registered marks of ACORD #S4115391/M4115046 KOS01 Client#:83393 LONGISL15 DATE(MM/DDNYYY) ACORD,., CERTIFICATE OF LIABILITY INSURANCE 2/07/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: Commercial Support Edgewood Partners Ins.Center PHONE 631-390-9700 AX No): 631-390-9790 AIC No a, 40 Marcus Drive E-MAIL ADDRESS: NECertificates ap icbrokers.com 3rd Floor INSURER(S)AFFORDING COVERAGE NAIC# Melville,NY 11747-2647 INSURER A:Southwest Marine 8 General Ins Co 12294 INSURED INSURER B: Long Island Power Solutions, Inc. INSURER C DBA New York Power Solutions INSURER D 2060 Ocean Avenue INSURER E Ronkonkoma,NY 11779 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTRR TYPE OF INSURANCE NSR WVD ADDLSUBR POLICY NUMBER POLICY EFF MM/DDY EXP LIMBS A X COMMERCIAL GENERAL LIABILITY PK202200020693 2/28/2022 02/28/2023 EACH OCCURRENCE $1 000 000 CLAIMS-MADE �OCCUR PREMISES(Ea occur,.".) cccu,nce) 000,000 X PD Ded:5,000 MED EXP(Any one person) $10 000 X Contractual Llab. PERSONAL BADVINJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 POLICY F JECT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ A AUTOMOBILE LIABILITY PK202200020693 2/28/2022 02/28/202 EOa accidertSINGLE LIMIT $1,000,000 ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS PROPERTY DAMAGE $ X AUTO NON-OWNED S ONLY Ix AUUT S ONLY Per accident A X UMBRELLA LIAB X OCCUR EX202200001789 2/28/2022 02128/2023 EACH OCCURRENCE $5 000 000 EXCESS LIAB CLAIMS-MADE AGGREGATE $5 000 000 DED I X RETENTION$10000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N E.L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? N I A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT 1$ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space is required) Town of Southold is included as additional insured for general liability coverage as required by written contract. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S3438616/M3437780 LJACO NY S I F PO Box 66699,Albany,NY 12206 New York State Insurance Fund I nysif.Com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 271175107 0 '� LOVELL SAFETY MGMT CO.,LLC , 110 WILLIAM STREET 12TH FLR NEW YORK NY 10038 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER LONG ISLAND POWER SOLUTIONS INC TOWN OF SOUTHOLD 2060 OCEAN AVENUE 53095 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2467 078-8 539135 04/01/2022 TO 04/01/2023 03/08/2022 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2467 078-8, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS:/IWWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT MICHAEL CATIZONE VICE PRESIDENT JOSEPH MILILLO TWO OF TWO OFFICERS LONG ISLAND POWER SOLUTIONS INC THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 396794370 111mI10000000000010 10 6®410101 Form WC-CERT-NOPRINT Version 3(0 8/2 912 0 1 9)[WC Policy-246707881 U-26.3 198 [00000000000102106564][0001-000024670788][##Z][15840-36][Cer[NoP-CERT_1][01-00001] 'Road APPROVED AS NOTED DATEio 11-Aa B.P. # 13 FE$ RDD• 00 BY COMPLY WITH ALL CODES OF NOTIFY BUILDING DEPARTMENT AT NEW YORK STATE & TOWN CODES E 765-1802 8 AM TO 4PM FOR THE AS REQUIRED AND CONDITIONS of: FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED SOUTHOLD TOWN SA FOR POURED CONCRETE 2. ROUGH FRAMING,PLUMBING, SOUTHOLD TOWN P M. N''IN`'G80ARD STRAPPING, ELECTRICAL.&CAULKING 3. INSULATION 4. FINAL-CONSTRUCTION&ELECTRICAL SOUTHOLD TOWN TRUS't'E'ES MUST BE COMPLETE FOR C.O. N.Y.$.DEC ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ELECTRICAL INSPECTION REQUIRED Additional Certification May Be Required. Ji5c0nncc,4 mud- be-, loca4r-) °', ' a c" I ke 1,fJ and Fla a i ly 0 Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2B Ph:631-988-0000 Bohemia, NY 11716 j G C solar@pacificoengineering.com August 29,2022 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Fred&Dorothea Salzberg Section-Block-Lot: 53-4-44.11 2890 Kerwin Boulevard Greenport, NY 11944 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A Mean roof height 18.0 ft Pitch 19 degrees Roof rafter 2x6 Rafter spacing 16 inch on center Reflected roof rafter span 13.4 ft Table R802.4.1(1)max allowable 14.6 ft The climactic and load information is below: CLIMACTIC AND Ground Wind Live Load, Point GEOGRAPHIC DESIGN Exposure Snow Speed,3 Pnet per pullout Fastener Type CRITERIA Category Load,Pg, sec gust, ASCE 7, load,lb psf mph psf Roof Section A B 20 130 33 660 SS 5/16"dia lag bolt,5"length Weight Distribution ®F NEB array dead load 3.5 psf �0 load per attachment 70.0 lb The subject roof has 1 layer of shingles. Panels mounted flush to roof no higher than 6 inches above roof surface. ' } Uff Ralph Pacifico, PE Professional Engineer 066 Ralph 4POWER PHOTOVOLTAICS: LUTIONS (25) REC395AA PURE 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 NEMA 3R (631)348-0001 JUNCTION BOX INVERTERS: BLACK-L1 ENGAGE CABLE (25) ENPHASE IQ7PLUS-72-2-US SALZBERG RED-L2 GREEN-GROUND CIRCUITS: RESIDENCE (1) CIRCUIT OF (13) MODULES (1) CIRCUIT OF (12) MODULES 2890 KERWIN BLVD GREENPORT, NY 11944 631-275-2508 S: 53 B: 4 L: 44.11 PROJECT DATA:#225985 INVERTER:(25)ENPHASE 1Q7PLUS-72-2-US MODULES:(25)REC395AA PURE RACKING:IRON RIDGE XR100 #12 AWG THWN FOR HOME RUNS UNDER 100' WATTAGE:9,87 #10 AWG THWN FOR HOME RUNS OVER 100' ROOF TYPE:COMPOSITION SHINGLES (1)LINE 1 (1)LINE 2 � a � � � �- METER WIND LOAD:-54.6PSF @ 140MPH (1)GROUND FASTENER:5/16"DIA.5"SS LAGS PER CIRCUIT 0® IlM l 30.25 A r \ IN 1"OR 14'PVC CONDUITRNIM a s 'i .T*#+ 240 pp ae Y + �' 1 aC DOTER " e PHOTOVOLTAIC 700 Lakeland Ave, Suite 2B • e� Bohemia,NY 1 i 716 4OADSIMs- ' MAIN SOLAR SYSTEM IN'T RE R POSITION, �C DISCONNECT LINE SIDE TAP Ph:631-988-0000 solar@pacifieoengineering_com www_pa c ifi c oe ng i n ee ri ng_corn 60A FUSED SERVICE MAIN SERVICE 125A LOAD CENTER RATED DISCONNECT 200A �®F Ns 90 AC®moo 0� (1)-20A BREAKER 409,FUSE PER CIRCUIT E i. IN DISCONNECT RTER�7llTPUT CONIC-�TlOid p I #8 AWG THWN #6 AWG THWN j ® NOT RELOCATE THUS ( )LINE 1 ('r INE 1 ALTERATIo xcEPTSY A OVERCURRENT DEVICE r (1)LINE 2 (1)LINE 2 LICENSED PRO IS ILLEGAL (1)NEUTRAL (1) AC DISTRIBUTION PANEL (1)EGG PAPER SIZE:11°x 17°(ANSI B) (1)EGG (11GEC OR SUB PANEL DATE: 8/15/2022 co IN 1"PVC CONDUIT L IN 1"PVC CONDUIT DESIGN BY: MW N CHECKED BY: EE REVISIONS: LL AC COMBINER: NOTE: 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, E■ 1-PHASE,MAIN LUG LOAD CENTER, 125A ALL WIRING TO MEET THE 2017 NEC AND 2020 ENERGY CODE TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE7-16. ELECTRICAL PLAN 60A FUSED SERVICE RATED DISCONNECT 0 Mn ER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 SALZBERG RESIDENCE 2890 KERWIN BLVD GREENPORT, NY 11944 631-275-2508 S: 53 B: 4 L: 44.11 PROJECT DATA:#226985 INVERTER:(25)ENPHASE IQ7PLUS-72-2-US MODULES:(25)REC395AA PURE RACKING:IRON RIDGE XR100 WATTAGE:9,875 ROOF TYPE:COMPOSITION SHINGLES WIND LOAD:-54.6PSF @ 140MPH FASTENER:5/16"DIA.5"SS LAGS LT�IEt,�11 c 161 111 � 700 Lakeland Ave, Suites 2B Bohemia, NY 11716 Ph_ 631-988-0000 solar@pacificoengi neering_com www.pacificoengineering-com Of NeP # MODULES (25) ._z. 17 14' 9 PITCH: 19 11' 7 AZIMUTH: 215' `�®,�� 0681�e 8.5' 0 ®'ESSI®�P ALTERATION 0 F]T EXCEPT BY A 4' O v LICENSED PROFESSIONAL IS ILLEGAL 0 PAPER SIZE:11"x 17"(ANSI B) Ln L ■ SPLICE BAR 10 DATE: 8/15/2022 © PENETRATIONS 76 DESIGN BY: Mw CHECKED BY: EE UFO 63 REVISIONS: 40MM SLEEVE 27 END CAPS 27 CONSUMPTION o CRITTER GUARD 180' MOUNTING PLAN L.'� + 1 AERIAL OWE R SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 /�/ (631)348-0001 "IO SALZBERG OA A RESIDENCE *onV 2890 KERWIN BLVD GREENPORT, NY 11944 631-275-2508 S: 53 B: 4 L: 44.11 PROJECT DATA:#225985 INVERTER:(25)ENPHASE IQ7PLUS-72-2-US qc MODULES:(25)REC395AA PURE C� RACKING:IRON RIDGE XR100 OSs� WATTAGE:9,875 p� ROOF TYPE:COMPOSITION SHINGLES SHEET INDEX O WIND LOAD:-54.6PSF @ 140MPH S-1 SITE PLAN FASTENER:5116"DIA.5"SS LAGS C S-2 DETAILS --: E-1 ELECTRICAL PLAN P.Cj L-1 MOUNTING PLAN E Gc O , nn E � 11'I E — D00 Lakeland Ave, Suite 2B R-1 SEP 0'1 2022 hemia, NY 11716 Ph:631-988-0000 # MODULES (25) BUILDINGDEP`r: PITCH: 19' -fOWvOFS-0tiTHOLD solar@pacificoengineering.com AZIMUTH: 21 -4" GENERAL NOTES www.pacificoengineering.com 3' -ENPHASE IQ7 PLUS MICRO INVERTER .r,EOFN-1 LOCATED ON ROOF BEHIND EACH MODULE. �P P� �q 1 -FIRST RESPONDER ACCESS MAINTAINED *C�o PPS ci��09 AND FROM ADJACENT ROOF. ^ v -WIRE RUN FROM ARRAY TO CONNECTION IS 40 FEET. -COGEN DISCONNECT IS LOCATED .o oss78c ADJACENT TO UTILITY METER. FFSSIOT4 a -LAYOUT SUBJECT TO CHANGE BASED ON ALTERATION OF THIS DOCUMENT EXCEPT BY ° SITE CONDITIONS AT DATE OF INSTALL LICENSED PROFESSIONAL ISILLEGAL 3 o PAPER SIZE:11"x 17"(ANSI B) Lo co LEGEND DATE: 8/15/2022 N DESIGN BY: MW 1 ® GROUND ACCESS POINT CHECKED BY: EE u- REVISIONS: COGEN DISCONNECT ® UTILITY METER c FIRST RESPONDER ACCESS 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, REPRESENTS ALL FIRE CLEARANCE MINIMUM OF 36"UNOBSTRUCTED AS PER TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE7-16. SITE PLAN S■1 a INCLUDING ALTERNATIVE METHODS THE 2020 RESIDENTIAL CODE OF NYS UFO- IronRidge XR 100 Rail $ OWER Aw. SOLUTIONS 4 2060 OCEAN AVENUE, ..� RONKONKOMA, NY 11779 (631)348-0001 SALZBERG Ca RESIDENCE Flashing 2890 KERWIN BLVD GREENPORT, NY 11944 631-275-2508 S: 53 B: 4 L: 44.11 IrwRidgeXR 100 Rail 1t PROJECT DATA:#225985 r IrouRidge XR 100 Rail S/1 6 X 5�� Stainless INVERTER.(25)ENPHASE IQ7PLUS-72-2-US _ Steel Lag Bolt MODULES:(25)REC395AA PURE Solar Module r RACKING:IRON RIDGE XR100 3/6-1 O X 3/4 r WATTAGE:9,875 HEX HEAD BOLT ROOF TYPE:COMPOSITION SHINGLES 3/8-18 FLANGE NUT ` •� ^ _�I//(�8�� WIND LOAD:-54.6PSF @ 140MPH {1 FASTENER:5/16"DIA.5"SS LAGS r` 1:1 G GENERAL NOTES: 700 Lakeland Ave, Suite'2B -L FEET ARE SECURED TO ROOF RAFTERS @ 80" O.C. Bohemia, NY 11716 USING 5/1611 x 5" STAINLESS STEEL LAG BOLTS. Ph 631-988-MOO -SUBJECT ROOF HAS ONE LAYER. solw paciciti°oenneerinneedi coo www pacificoengineering com -ALL PENETRATIONS ARE SEALED AND FLASHED. �P S OF NFyy *� PP�pH p40/ ROOF PITCH RIDGE RAFTERS LENGTH OVERHANG NOTES R1 190 NA 2"x6"@16"0.C. 161-111 12If TRUSS 9�FFSSIONP�'�� ALTERATION EXCEPT BY A 3 LICENSED PROFESSIONAL IS ILLEGAL PAPER SIZE:11"x 17"(ANSI B) LO Go � DATE: 8/15/2022 N N DESIGN BY: MW CHECKED BY: EE REVISIONS: E� a� N N M In N DESIGNED AS PER ASCE 7-10 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, S■2 MODULES MOUNTED FLUSH TO ROOF TOWN OF SOUTHOLD CODE 2017 NATIONAL ELECTRIC CODE.ASCE7-16. DETAILS in NO HIGHER THAN 6"ABOVE ROOF SURFACE OWER PHOTOVOLTAICS: SOLUTIONS (25) REC395AA PURE I 2060 OCEAN AVENUE, NEMA 3R RONKONKOMA, NY 11779 JUNCTION BOX INVERTERS: (631)348-0001 BLACK- L1 ENGAGE CABLE (25) ENPHASE IQ7PLUS-72-2-US SALZBERG RED- L2 GREEN -GROUND CIRCUITS, (1) CIRCUIT CUIT OF (13) MODULES RESIDENCE (1) CIRCUIT OF (12) MODULES 2890 KERWIN BLVD GREENPORT, NY 11944 631-275-2508 S: 53 B: 4 L: 44.11 PROJECT DATA:#225985 INVERTER:(25)ENPHASE IQ7PLUS-72.2-US MODULES:(25)REC395AA PURE #12 AWG THWN FOR HOME RUNS UNDER 100' RACKING:IRON RIDGEXR100 #10 AWG THWN FOR HOME RUNS OVER 100' WATTAGE:9,875 (1)LINE 1 i ROOF TYPE:COMPOSITION SHINGLES (1)LINE 2 + ! WIND LOAD:-54.6PSF @ 140MPH (1)GROUND METER FASTENER:5/16"DIA.5"SS LAGS PER CIRCUIT © 1�'1 1C 1 111 30.25 AIN 1"OR 14'PVC CONDUIT - NOMINA IL OPMT %TAC;;9- 240 VELECTRIC SHOCK HAZARD - IN G Ic •• PHOTOVOLTAIC --- �---- ;� 700 Lakeland Ave, Suite 2B Bohemia, NY 11716 •'' ` ` �! MAIN SOLAR SYSTEM IN THE OPEN POSITION AC DISCONNECT _ __ _ Ph- ss1-s88 aaoo LINE SIDE TAP ____ solar a@pacificoengineenng.com www pacificoengineering.com 60A FUSED SERVICE MAIN SERVICE 125A LOAD CENTER RATED DISCONNECT 200A OF Ns— (1)-20A BREAKER 40A FUSE Gj�QP�Q -yv PER CIRCUIT AWAR I N DISCONNECT INVERTER OUTPUT CONNECTI0N DO NOT RELOCATE THII S #8 AWG THWN #6 AWG THWN 06618`a 9VERCURRENT DEVICE (1)LINE 1 (1)LINE 1 O� N (1)LINE 2 (1)LINE 2 ALTERATION XCEPT BY 3 (1)NEUTRAL (1)NEUTRAL LICENSED PRO QR CLIS ILLEGAL 7 (1)EGC (1)EGC AC DISTRIBUTION PANEL PAPER SIZE:11"x 17"(ANSI B) LO rn IN 1"PVC CONDUIT (1)GEC OR SUB PANEL DATE: 8/15/2022 N IN 1"PVC CONDUIT DESIGN BY: MW N v CHECKED BY: EE REVISIONS: a N ti v AC COMBINER: NOTE: 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, 1-PHASE, MAIN LUG LOAD CENTER, 125A ALL WIRING TO MEET THE 2017 NEC AND 2020 ENERGY CODE TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE7-16. ELECTRICAL PLAN E.1 60A FUSED SERVICE RATED DISCONNECT V. Em R SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 SALZBERG RESIDENCE 2890 KERWIN BLVD GREENPORT, NY 11944 631-275-2508 S: 53 B: 4 L: 44.11 PROJECT DATA:#225985 INVERTER:(25)ENPHASE IQ7PLUS-72-2-US MODULES:(25)REC395AA PURE RACKING:IRON RIDGE XR100 WATTAGE:9,875 ROOF TYPE:COMPOSITION SHINGLES WIND LOAD:-54.6PSF @ 140MPH FASTENER:5/16"DIA.5"SS LAGS PP01NI Ep 16 -1 700 Lakeland Ave, Suite 2B Bohemia, NY 11716 Ph: 631-988-0000 solar@pacificoengineering.com www.pac ifi c oeng i n eeri ng_c om �e of NS R-1 '�PQ�90 PAC/,�i�,�,Q # MODULES (25) 17' 9 PITCH: 19° z 4 11' 7 AZIMUTH: 215° 8.5' 0 9 st- ALTERATION O - -T EXCEPT BY A p 0 LICENSED PROFESSIONAL IS ILLEGAL 3 4' PAPER SIZE:11"x 17"(ANSI B) co ■ SPLICE BAR 10 DATE: 8/15/2022 © PENETRATIONS 76 DESIGN BY: MW CHECKED BY: EE m UFO 63 REVISIONS: 40MM SLEEVE 27 N END CAPS 27 N CONSUMPTION o CRITTER GUARD 180' MOUNTING PLAN L.'� x,. Y REC ALPH. PURE64 tM �# , 'A �,t 405wp 7M771 , w �i 219 '�� �' REC PRODUCT 5PEEIFICATION5 SOLAR'S MOST TRUSTED 1821t2.5[71.7t0.11 _ CERTIFICATIONS ,G�� za[t.11 a 901[3551_ 460[18.11 IEC 61215:2016,IEC 6.. 1730:2016,UL 61730 IEC 62804 ............. PID - _. 153.7[6.05] i IEC 61701 ;Salt Mist_..............._,. .._ . .._.... ............................:...._:-..............:...:- e :._.- t t oo[a3.3]+ 1 IEC 62716 1Ammobnila Resistahee IS011925-2 �Ignita i ity(Class'E) - r ..........................................•....... ..:.-,.__-,:.,-_. ..__. .... ::..-...._..; IEC 62782 0yriamie,Mechanical Load,, p� [o.zato.ot] IEC 61215-2:2016 14ilsiarfe,(35mm) .................................... _:.:•r-...,......�.,.,..........._.._. IEC62321 Lead-freeacc!,.b 6HS,EU863/Z015 m ISO 14001:2004,ISO 9001:2015,OHSAS18001:2007,IEC 62941 u * OI N eVE `a- C E take Ewa rake-ewayWEEEcmnplianc f t t0.2 rn h-k Lead-Free recychgschwe o'[0.43t0:01] WARRANTY' u2ostos q , ..................................... olarProfessional ........... RECProTwt . q •rT Installed byan REC Certified `' N, ..�.....::..:__:......:........_,: 1200[47.21 d 153 7 •' S .. Xes, ...... ......... ..�:..',.,:...-.._::..: -:.-.Yes.-:::i System Size . All, s25'kW 25°SOO kW, -45[7.81 zzs[os] 671 t3[26.4 t0.12] Product Warranty(yrs) i',:'20;' - �-----------------------► .................................................:..........,-......... ...:,:..,_.:.:._....,._.....,:.._ 130[t.z1 Power Warranty ;- 25-, r "2S 25 t ............................._...,......-:._...... _........-......... Measurements inmm[in] LaborWarranty(yrs) 0 2S't 10- Power in Year 1....................................:...=98%,.,..:,.980/:-._.. °98%-: pj GENERAL DATA -_.:..- -..:....,o-.,-E............................................ ] 7_,-_ Annual Degradation Oi25,/0. 1'0:25/_.'".0;25/0 " .............................. ........... _ ..:_:.._ 132half-eutRECfiete,rounctioncells StaubliMC4PV-KBT4/K5T4(4MM2)1 Power in Year25 -,,92% ^92%_ .92%. Celltype: with'lead-free,gaplesstechnology_E Connectors: in accordance with IEC 628S2; See wa rra nty do cum ents for deta ils.Can ditio ns a p ply .;6stringsof22cellsinseries') x IP68onlywhericannected :3.2mmsolafglassw]th) 4m_rri2solan•cable;lam+12'm'l `BMAXIMUMRATINGS Glass: Cable: 's` anti=reflective surfacetreatment; `, ,. ''inaccordance;witfiEN5o618;4 Operationaf;temper`ature•: -~;c40::+85°,C? .. :_...._...:: ...................:....:..._:....s..:.:..;;......:__. .......I................ ......... _... _ _ -. Maximums' stemvolta 1000VBackgheet: -Highly-sistantpolymer(blac )' Dimensions: , T2103 x11mm.; ? ............................ .;:...:_...::.....,..-..... :,:,:.-:....... .c _ ..... __::.-_.::.:............ Maximum tesf,load(frbnt)i, ' +7000Pa(713'kg/m2)%, c Frame: :Anodiied;alumihum,(b[aek)^j Weight: i - 20.5'kg, Mazimumtestload(rear):• 4000;Pa(407kgJmz)'1 ........ ............`:....._. ...... ..................._..........:...:.. ..__ _.. :... .._ _ p yp diodes Lead free 'l Maxsenesfu'serating:. « 25A 3 Junctionbox:;;' IP68ratd3 acc° l Origin: Made in Singapore.; T _e_ ancewithlEC62790 j MaxrevecsecurrenC' 4N - 25'A`' ". See installationmanualformountinginstructions. o y ELECTRICAL DATA Product Code*:RECxxxAA Pure' _ Design load-Test load/1.5(safety factor) Power Output-PMnx(WP)...................................';. ..' 385....,_....:.:..e390: .... .;..395'...;.:::. .400 ;. ,4'0S TEMPERATURE RATINGS- .... .... Watt Class Sorting-(W) _._. 0/+5....... 0/+5 0/+5 x 0/+5 0/+5( .- ........ ......... ............................. Nom,nalModuleOpefati,ngTemperatufe: 44.' (t2 C): s Nominal Power Voltage-VMpp(V) 41:2' 4:1.5 .:.c 41i8 :42.1` 42.4'[ - _ _-_ _ ....... Temperature coefficient df P. 0.26//C j..........................::-.,....-.-.«...,:,:...-....__-.._.._-.,.._.;:•-._ce..-«.__....-.-.........,...._......_._.._..-....:: _ MAX'.�a _ vin NominalPowerCurrent-I (A) 9;35 9.40- :9.45- 9.51 9,561 V 1- .................................................Mpp..............................5.::.::.:..;.::.-.::..:_...:::..-.:...-:.:.:..._:..r:::.:.:.._....:...._:..:_..............._:.:.....:.. TeTrn efature"coefficientdfV.......•:_ _0.24%''CI vai ,- _ Open Circuit Voltage-Voc(V) '.48.5, 4816, _;48.7:' ' ' 48.8: 48.9y - - • 04'%°C ....................................................................................,.--..,.-.-.:........_:.... :,..-...s_.-.............:.::.::.- :::::..:..............::-_:.....:. _ _ _ Tempe�at utecoefficierit'ofls�:',; ..' .0: ../ Short Circuit Current-Isc(A) 0':15 1020: `10.25 10.30 ^'The Ftemperature coefficients stated are linearvalues ..........................._........................................................,.,._,.._..,......... ....... .._ .,: ;.....-::..._,:.,._...._............. .:_.,-._...«.._;...-......_._ Power Density(W/m') ;, 208.1 2.10.8,_ 213:5 216.2: '219;0 BEHAVIOUR�7L0 .........._............................................................_......-,.,.-._,... .:..:, :-....._-_..--.-- :..:...... .216....:...........219:,._ Panel Efficiency(%) 20:8-'' 21:1:'". 21.8-1,' _'21.6. 21-9 =' '_• .., -., Typica-1 w- rradiarce performance ofmodule at STC 305 wi m301 309iPower Output-P.X(Wp) 297• ..................... . .. Nominal PowerVoltage-VMpp(V) 38:'8" 39.1 `39.4' 39.7 40~O.i oc .. . 2 NominalPowerCurrent-IMpp(A) !' 7.55:; 7:59. -7.63 '., 7.68` 7.721 ------ ----- ------- a .................................................................................:.....::.... _ Open Circuit Voltage-Voc(V) 45.7 -45.8"- ',.'_ ;45,9.` "46.0` ;46:11 - ;`= __ - ) :i- , v .................................................................................... ... .::........................ ....:..:..«.........,..,:..:_...,.............._........,............-........ - ShortCircuitCurrent-Isc(A) 8:16 820- 824 `8.28 8.32i 7j Irrddiance'(W/m']+®` - I a a Values at standard test conditions(STC:air mass AM i.S,irradiance 1000 W/m�,temperature 25°C),based on a production spreadwith a tolerance of Pam,V,,C&Isc±3%within one watt class.Nominal module operating temperature(NMOT:air mass AM 1.S.irradiance 800 W/m',temperature 20°C,windspeed 1 m/s).*Where xxx indicates the nominal power class(P_)atSTC above. c�.^��x�:��M,:-=.xca�� _...._r�-•�sy,.�,__�-.�....a.----•:a;.�^vr_-�c_.......__.�'___...:.__._.�_.._---�..�.�.-•---�•-�..._v-«;x.._...-,_�v,:,-___�-._�, .__ ��,_.�-..e:�..�- Founded in 1996,REC Group is an international pioneering solar energy4 ( 1 company dedicated to empowering consumers with clean,affordable R EC solar power.As Solar's Most Trusted,REC is committed to high quality, www.recgroup.com innovation,and a low carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational 0 'Q headquarters in Singapore,REC also has regional hubs in North America, Europe,and Asia-Pacific. 0 Data Sheet Enphase Microinverters Region:AMERICAS The high-powered smart grid-ready Enphase Enphase IQ 7 MicroW and Enphase IQ 7+ Micro'm. I + dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy"', Enphase IQ Battery'm, and the Enphase Enlighten" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple • Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements Remotely updates to respond to changing grid requirements :. • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U� *The IQ 7+Micro is required to support 72-cell modules. I ENPHASE. To learn more about Enphase offerings,visit enphase.com Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US S Commonly used'modul'e-pain ngs' •235 W-350 W+, 23.5 W'-440 W+ _ »Module compatibility 60 cell PV modules only ­60 cell and 72 cell PV modules Maximum input DC voltage ,: 48 V Peak power tracking voltage 27 V-37 V 27 V-45 V 16- 16V�-,60V'' 2- Min/Max Min/Max start voltage 22 V/48 V 22 V/60 V Maz DC short circuit currerit:(modtile Isc) . ,15.A - 15A Overvoltage class DC port II II < -- - - m - -D - - ._-.._..M ____._;".:._:_..._._.,;,- ._ •.: .�.•,�. �•-•___:____��...:._,.,:__:...:.:...:,.._:d____- ad -.-...macz.�_��_..:__.M_.=•__:�.�-•_.--._ .::....r:.-..-::�-•._w`,- _---_:.......:.. ... PV array configuration 1 x 1 ungrounded array;No l DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter :Peak outputpower. - 250:VA':.` - 295 VA Maximum continuous output power 240 VA 290 VA Nominal{L•L)voltage%%ange?.". ',,24.0�7% - 2Q8 V%`': 2'40 V/;-- '`: 208 _ _ __ _ :211 264.V' 183 229=V "`_ 211:264'V " 183=229;V _ �.a': Maximum continuous output current~ 1.0 A(240 V)•_ 11..15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) ^ - -. `- - - - - - - Nominal frequency -_ x :'60'Hz 60 Hz.:, Extended frequency range 47-68 Hz 47-68jHz AC'short•circuif fiauft-current over,3.c'Iles: :r. 58-Arms µ` ." _ '5 - _ _ _ _ _ _ Maximum units per 20 A(L`L)'branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) - - Nervoltageclas';'AC:port '. ' -,.Ili AC port backfeed current 0 A 0 A Powerfacto�setting- - Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V CID e_ak•C_ECefficiency.. -- - 97:6.°io:_._.. ....__ '97.b`°i° _..v..__9_7.5_%`,- ..`..._: _ :9_7_3°i - CEC weighted efficiency 97.0% -97.0%° 97.0% 97.0%° MECHANICAL DATA Ambient tein erature,ran e' `' 40°,C to+6'50C Relative humidity range 4%to 100%(condensing) Connector.;type,(IQ7 60 2,US'&IQ7PLUS 72 2 US)y MC4;(orr Amphenol�H4MTXwith additional Q=DCC,5 a_dapter)s::'- ;.';;'- :'": '•. . ` Connector type(IQ7-60-B-US&IQ7PLUS 72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 •,Dimen`sions;(W'zHxD).,: :2'!2 mm:z:175 rn_m x 30.2 riim(without bracket Weight `. __,.. .... - _..._. -1.08 kg(2.38Ibs) Cooliri "Natu'ral convection=:N o f Approved for wet locations Yes Pollu#'ion degree r P:D3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Envi onmental category-%rUV exposure rating 1` N_E-MA:Type 6/outdoor:;r_'. .`; t FEATURES Communication; ?: Power Line Communication(,PLC): Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. __ _-__.__._._._ ..._ Djsconriectirig'means,_ ,=`.:'.'' .:= '- Th6ACandDCco,hnectors•have;lieenevaluated'and`approvedtiy.UL#oruse,;asth'eload-break.':'• ' •.-, . . isconnectrequire'daiy NEC:69.0: Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at httos7//enchase com/en-us/support/module-com ato ibility. 2.Nominal voltage range can be extended beyond nominal if required bythe utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com E N P H AS E. ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 IRONRIDGE Roof Mount System It 5 i r ram✓'"• „ 'Y$"'' 5F }r,�".f: ;::s`>:". .. ., e .. Y ° xf�r Built for s lar's tou"9hest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified ° r = All components evaluated for superior - Pre-stamped engineering letters structural performance. available in most states. ` Class A Fire Rating Design Software rx ' Certified to maintain the fire resistance - Online tool generates a complete bill of rating of the existing roof. d=- materials in minutes. Integrated Grounding #` =' 1' 20 Year Warranty UL 2703 system eliminates separate `.'• Twice the protection offered by A`°"' module grounding components. competitors. XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices J A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability 12'spanning capability Self-tapping screws • Moderate load capability Heavy load capability Extreme load capability Varying versions for rails • Clear& black anod.finish Clear& black anod.finish Clear anodized finish Grounding Straps offered Attachrnents FlashFoot Slotted L-Feet Standoffs Tilt Legs raw t Anchor, flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail IBC& IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware • Certified with XR Rails Clear& black anod.finish 4"and 7"Lengths Fixed and adjustable Clamps & Grounding End Clamps Grounding Mid Clamps Q T Bolt Grounding Lugs Q Accessories t - r7 r. :. Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish & black anod. Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips • Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps • Optional Under Clamps Mill & black stainless Swivels in any direction UV-protected polymer Free Resources _ _ = Design Assistant , A NABCEP Certified Training = Go from rough layout to full `. v Earn free continuing education credits : 9 Y Y 9 , t, engineered system. For free. while learning more about our systems. -. Go to lronRidge,c mirm �V Go to IronRidge.com/training IN