Loading...
HomeMy WebLinkAbout48712-Z o�OS�FFQI'�cpG Town of Southold 5/4/2024 y� P.O.Box 1179 0 o _ 53095 Main Rd yjj0l Sao Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45161 Date: 5/4/2024. THIS CERTIFIES that the building FIRE ALARM Location of Property: 74785 Route 25, Greenport SCTM#: 473889 Sec/Block/Lot: 45.4-8.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/9/2023 pursuant to which Building Permit No. 48712 dated 1/9/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: fire alarm system installed to existing commercial building as applied for. The certificate is issued to New York Telephone Co of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED Authorized Signature �S�FF01 TOWN OF SOUTHOLD �o Gyp BUILDING DEPARTMENT H x. TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES. WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48712 Date: 1/9/2023 Permission is hereby granted to: New York Telephone Co Attn: Verizon PO BOX 2749 Addison, TX 75001 To: Install fire alarm system At premises located at: 74785 Route 25, Greenport SCTM #473889 Sec/Block/Lot#45.-4-8.1 Pursuant to application dated 1/9/2023 and approved by the Building Inspector. To expire on- 7/1012024. Fees: FIRE ALARM SYSTEM $250.00 CO-COMMERCIAL $50.00 Total: $300.00 Building Inspector a�o�g�FFQtk�oG TOWN OF SOUTHOLD—FIRE MARSHAL Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 littps://wm.v.Southoldtownny.gov FIRE PROTECTION SYSTEM PERMIT Date Received APPLICATION For Office Use Only PERMIT NO. /Z Building Inspector: (ALi :a PP ;t s ;be;'filled;onf'1n their;;en"tiref"`',Iricomplete r a,pplcations,'will notbesacceptei�,`WORK§IS'NOT:'TO BTART_EDw ,lily 1191 7 Il')'� ,to;'the:a roval'-of plans;and`i "sstiance;of'a a"rmi zt Has a buildingpermit been obtained for this project? ❑Yes ©No t liifilir�` p p J O 30MOLO If yes,building permit# Date: �PROJ%r+t�' ::sr, :.�;s:..ay.% ^rx�•: v.'uy'..sti.'.t:�i;si�.'` ,.r4wx. ,!;�',` wi,,•p�: - .. .t,,, ECTINORM' ��� ;+��' =':,�:r.,'-`� •.-.: " c�'.. r>.;. - ��::���'. +fi:,,4+ „)i�','p'•�,. r.�}.an.','•` - ,^�i°....•e.[' '�Ci.Y;"-aft �j}%!:"'g5.r.. .•1. Project Address:Verizon 74785 Main Road SCTM# 1000-45/4/8.1 city:Greenport _ » _ _ Zip:11944 Mrd �!`� r wf•�"n' e:b.`tL".,*'-r,5<.•aAs'.+tA "¢'• :?:. a_- _ .C.ONTAC.: swP: ::�=�;�3•. .�: ..�•._... ;:��`,•.. •,�'� � .,.z��r. �.� ��>�,,:`:! �, T. ERS.ON>IN��ORNIATICIN. s'- �.t'r.. ,,.,• �:: ���'. ,•. ,L�,.,'�>,���.,., - +•r•8,�.r.._ vr.:--- -.�: - r.��.3u�'i:``;d'•r...t.,'{;:.,,;. i}'.`r^ .�.�,�1'.+"MT^'i 't, ''1�.':. i+l�.^.x4,: �4-.!r`.":'s^r'rt.,4��<�s ti',"�; i.'1• i��.",',`^: .t.^r `T �,3.. �.w',, n,.,.,vw.n.;wr°•'',t,p.�if,'�e.'t».v.`,.b„.,�,1a Name:James Doherty Mailing Address:500 Johnson Ave,_Bohemia,NY 11716 Phone#:631-873-9437 Email:'dohpq commanderelectric.com Preferred contact method(select one): ❑Phone [-Email _ }` f �. ".'4-.+ it:1'X.� ;7"•. .2 INFOI2MtI,TION• -,..'�,, •::�=- s"= `�:i:,. �-���a''«, .e..-.... *t - .,y. .,h n a-.A- :A. ..ro�•" .oy, .r. �qv ,s," r:'s` t t:*. ..e .s.'S� S. ,lr. �'iF!! os t: - �'�. -"t5:'`'—c..,+Y'::-. �•<Qi.-.,sL:k2 1.. :;r..? '.'�� ;'y". ,,i1' V. - :jr?�;:',--.. p� - fir cf +;1�..,..,y,,a y �r.,:i'�''.'-vt,•¢, Name:Commander Electric Contractor License#:ME_-50062 _ _ Mailing Address:500 Johnson Avenue Bohemia NY 11716 Phone#:631-873-9437 Email: gy'dohe com_man_derele_ctric.co_m _7..@..� _ .. °tom _ ?'�.,:is• .•�E'c ;� ::rt<o.++. .�r. .'.ss' '"i9';iir "r:M•.a `�::•.< '�,. .f"."':�., 'i�•�'.,".•.#.:�. z�'r"' .�'k�,. 3P. .rn �SCOPE�OF.WORK: ."�, w, :r..,�ry.� =r.; r,, ,•rr, �;�.' •rj�v :�: _ .,,. �' .�,�:r.+;;.,. z:.�.^A'sr.o.r,..� ,d,,,s:, .,n_ ''.*�,�. `,t' .r 'x^�'.• .*, rx�: ��V� - %'ttip, ,,��,,?,', '�i.:'" '.x. .}.i,..'£ +r��� l.. .� e'(�}$a -.tom• s� :':i°.d:;* �::+;�+ - ",1�+�;t:c •4. .`ty;�i'. w,^r, _mot.. .:,�:w�:'.": .r�a. v...}, •'�`f?c^ Occupancy Description: ❑Assembly ❑Business ❑Education 8 Factory/Industrial ❑Institutional ❑Mercantile ❑Residential ❑ Storage Description of Work: Installation of a Temporal.3 Fire Alarm System with Aspiration,Detection _ B New System ❑ Existing System Modification ,{ '._.," .,`w.._» JAM?i�•���� S rinkler'%Starid i e" fir P i p p.,../Wafer<Su 1 Fre..Alarni.:%;CO;Detectro �_„ pI?Y' y.,.., - _ n=�Systems:�'.i .�.. :.Otlie`r`'Fire��ProtectioniS. s°te`'ins� ry v.;:;;:..,-'-ear ,:> ;a•;., ,a�+,...>_: ..,t•,. .Y, r ♦r 5. -, lies lc�al•;�.t 1 liaY:a' v ;Ghee ll-t l��that�' .`,•'� k�a � lat''a` 4 f:�:,��'�S'�'� �i.'1..;`:�: t"I i.�. - .:t'.-.r�•li :'j<�' ��• i�,`'`"•�'i. �� ❑NFPA 13,13D or 13R System RManual (]Automatic ❑ Smoke Control ❑Standpipe ❑Fire Pump ❑Protected Premises(local) ❑.Wet or Dry Chemical/Clean ❑Supervising station Agent Number of sprinkler heads: 0 RCentral Station ❑Kitchen hood/exhaust ig Other Floor Area(sq.ft.): __.._......_. ._. . ...._.._.....----..... __....».._. 1 . 8'Cheek.Box After-Reading:';I;the•undersigned,:underst indthat the issuance.of a permit:forahe type.whick is herein'applied,for is'based,on• ,the agreement•to,conform'to all iegulatious,and requirements:I further understa4d"that non-compliance of said requirements,by myself any officer or ;employee ofthe firm or individual,l'isted;as,the-applicant on'this form;'shall because'for revocation'of saidpermit,tfpon revocation of said,permit'tIt - applicant or any,employee'of the applicant shall be piohibifed,to-coaduct•such work for<which'this permit was issued:The,rei'ssuance of a permit shall be ,,Used upon review of the circumstances leading-to the7evocation,Anyyfalse statements)made herein'are'punishatile as a'Class A misdemeador pursuant to section 210.45 of the Penal Law,~ Application Submitted By(print name): []Authorized Agent ❑Owner Company(if applicable): Applicant Signature: FIRE PROTECTION SYSTEM PERMIT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE ALARM/CARBON MONOXIDE DETECTION SYSTEM SUBMITTAL GUIDELINES • FIRE SPRINKLER SYSTEM SUBMITTAL GUIDELINES • FIXED FIRE SUPPRESSION, HOOD& EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$250 permit fee is required for a non-residential permit.A$50 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testinglinspection shall be made by contacting the Town of Southold Building Department(631)765-1802. FOR FFI E`, O C USE ONLY',';:_ Amount.Paid: Zd. Check No:: c' 894 ,�6,8 FM:,` 0: Permit Ni x + ate,J / r 2 OF SOUI,s°� # TO F SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G.. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: CI) e DATE / INSPECTOR FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-31 FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: yerizon Address: 74785 Main Road,Greenport,NY 11944 Representative of protected property(name/phone): lames P.Dillon 516-297-0440 Authority having jurisdiction: Southold Fire Marshal Address/telephone number: 54375 Main Road,Southold,NY 11971-0959 Organization name/phone Representative name/phone Installer Commader Electric 631-563-3223 James Doherty 631-873-9437 Supplier Honeywell-Notifier Service organization Commander Electric Location of record(as-built)drawings: Document Box at the Main Panel Location of operation and maintenance manuals: Document Box at the Main Panel Location of test reports: Document Box at the Main Panel A contract for test and inspection in accordance with NFPA standard(s) Contract No(s): Effective date: Expiration date: System Software (a)Operating system(executive)software revision level(s): (b)Site-specific software revision date: (c)Revision completed by: (name) (firm) 1.Type(s)of System or Service NFPA 72,Chapter 6—Local If alarm is transmitted to location(s)off premises,list where received: NFPA 72,Chapter 8—Remote Station Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others,indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72,Chapter 8—Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others,indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: XNFPA 72,Chapter 8—Central Station Prime contractor: Rapid Response Monitoring Services, Inc. Central station location:400 W. Division Street, Syracuse, NY 13204 (800)558-7767 (NFPA 72,1 of 4) FIGURE 4.5.2.1 Record of Completion. _ I _ ___� _ r__ ' 1 MAR 1 8 9024 2002 Edition 72-32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-way radio XDigital alarm communicator Two-way radio Others Means of transmission of alarms to the public fire service communications center: (a) (b) System location: NFPA 72,Chapter 9—Auxillary Indicate type of connection: Local energy Shunt Parallel telephone Location of telephone number for receipt of signals: 2.Record of System Installation (Fill out after installation is complete and wiring is checked for opens,shorts,ground faults,and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below,was inspected by on ,includes the devices shown in 5 and 6,and has been in service since NFPA 72,Chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply) NFPA 70,National Electrical Code,Article 760 Manufacturer's instructions Other(specify): Signed: �/ / Date: Organ�attio C�G�G�#.J L �x� � 51t►� 3.Record of System Operation Documentation in accordance with Inspection Testing Form,Figure 10.6.2.3,is attached All operational features and functions of this system were tested by date and found to be operating properly in accordance with the requirements of: �LNFPA 72,Chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply) NFPA 70,National Electrical Code,Article 760 Manufacturer's instructions -,C_.Other(specify): A ` Signed: Date: �J Organzatio 4.Signaling Line Circuits Quantity and class of signaling line circuits connected to system(see NFPA 72,Table 6.6.1): Quantity: 2 Style: 4 Class: B (NFPA 72,2 of 4) FIGURE 4.5.2.1 Continued 2002 Edition FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 5.Alarm-Initiating Devices and Circuits Quantity and class of initiating device circuits(see NFPA 72,Table 6.5): Quantity: Style: 4 Class: A MANUAL (a)Manual stations Noncoded Transmitters Coded Addressable 2 (b)Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete YES Partial Selective Nonrequired (a)Smoke detectors Ion Photo Addressable 20 (b)Duct detectors Ion Photo Addressable 3 (c)Heat detectors FT RR FT/RR RC Addressable 2 (d)Sprinkler waterflow indicators: Transmitters Noncoded Coded Addressable (e)The alarm verification feature is disabled or enabled ,changed from seconds to seconds. (f)Other(list): Addressable Smoke/CO Combo Unit-2 Addressable CO Detector-1 6.Supervisory Signal-Initiating Devices and Circuits(use blanks to indicate quantity of devices) GUARD'S TOUR (a) Coded stations (b) Noncoded stations (c) Compulsory guard's tour system comprised of transmitter stations and intermediate stations Note:Combination devices are recorded under 5(b),Manual,and 6(a),Guard's Tour. SPRINKLER SYSTEM Check if provided (a) Valve supervisory switches (b) Building temperature points (c) Site water temperature points (d) Site water supply level points Electric fire pump: (e) Fire pump power (f) Fire pump running (g) Phase reversal Engine-driven fire pump: (h) Selector in auto position (i) Engine or control panel trouble 0) Fire pump running ENGINE-DRIVEN GENERATOR: (a) Selector in auto position (b) Control panel trouble (c) Transfer switches (d) Engine running Other supervisory function(s)(specify): (NFPA 72,3 of 4) FIGURE 4.5.2.1 Continued 2002 Edition 72-3,1 NATIONALFIIl1"ALNIU COf)fi 7.Annunciator(s) Number-_I Type: LCO2-e0 ),ttculion: Main Entrance 8.Alarm Notification Appliances and Circuits NFRA 72,Chap(er li—Emergency Voice/Alarnt Service Quantity of voicclnlarnt channels: Single:-- Multiple: Quantity irspeakem installed: Quantity of speaker zones: Qu tin t(ly of telephones or telephone jacks included in system: Qunn Lily and the class of notification appliance circuits connected to system(see NFPA 72,Table G.7): Quantity: 3 Style.- 4 Closs• A Types and quantities of notification appliances installed: (a)Bells With Visible tb)Speakers With Visible (c) Iforns With Visible 24 Id)Chines With Visible tel Other: With Visible if) Visible appliances without nudible: 3 Fire Norm Strobes and 4 CO Strobes 8.System Power Supplies (a) Fire Alarm Control Panel: Nominal voltage: 120VAC Current rating: 5A Overcurrent protection: Type: Current ruling Location:Main Entrance Hall (b)Secondary(standby). Storage buttery: 2.12V Amp-hoar rating: ISAH Calculated capacity to drive system,in hours: Engine-driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency system used as backup to primary power supply: Emergency system described in NFPA 70,Article 700: 10.Comments Frequency of routine tests and inspections,if other titan in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s)are: .1. r IaU6n /su(5r contract PR liar '(lido) (dato)r` �' p (signed)for alarm sorvica company (late) (date)c (signed)for central station (illo) (date) Upon completion orthe system(s)satisfactory test(s)witnessed fif required by the authority ImAng jurisdiction): (signed)roprenontove of the authority Knring jurisdiction pitfo) (date) (NFPA 72,4 of 4) FIGURE 4.5.2.1 Confinurd 2002 Edition B 0 - D e p o' a 0" o •� D e D o .9- o., -�O . -'D 6 . - x - z" '� f- '�� Central Station Point Address f ;;R�•`�= ��� •f IACS Point Function�ACSPointAddres Source I TypeCodeLabel f PanelLabel l Custom Label Extended Label 1 Pull Station A22P1 N0L1M1 Pull Station VERIZON GREENPORT FRONT ENTRY 2 Fire Alarm A22P2 N01-1 M2 Nonreset Ctl VERIZON GREENPORT FAN SHUTDOWN AC 313-01-01. 3 Supervisory A22133 N01-1M3 Track Supery VERIZON GREENPORT HVAC STATUS AC 313-01-01 4 Fire Alarm A22P4 N01-1M4 Nonreset Ctl VERIZON GREENPORT FAN SHUTDOWN AC 313-01-02 5 Supervisory A22P5 N01-1M5 Track Supery VERIZON GREENPORT HVAC STATUS AC 313-01-02 6 Fire Alarm A22136 N01-1 M6 Control VERIZON GREENPORT CO STROBE HVAC ROOM 7 Fire Alarm A22P7 N01-1M7 Nonreset Ctl VERIZON GREENPORT FAN SHUTDOWN AC 340-01-01 8 Supervisory A22138 _ N01-1M8 Track Supery VERIZON GREENPORT HVAC STATUS AC 340-01-01 9 Fire Alarm A22P9 N00 M9 Monitor VERIZON GREENPORT FLAME DETECTOR GENERATOR RM 10 Fire Alarm A22P10' NOL1 M10 Control VERIZON GREENPORT CO STROBE GENERATOR RM 11 Fire Alarm A221311 NO1-1 M11 Relay VERIZON GREENPORT GENERATOR SHUTDOWN 12 Supervisory A22P12 NOL1M12 Track Supery VERIZON GREENPORT GENERATOR STATUS 13 Fire Alarm A22P13 NOL1M13 Control VERIZON GREENPORT CO STROBE HALL BY BATT 14 Fire Alarm A22P14 NOL1 M14 Nonreset Cti VERIZON GREENPORT FAN SHUTDOWN AC 340-01-02 15 Supervisory A221315 N0L1 M15 Track Supery VERIZON GREENPORT HVAC STATUS AC 340-01-02 16 Supervisory A221316 N0L1M16 Track Supery VERIZON GREENPORT 24V SUPERVISION 18 Pull Station A22P18 N0L1 M18 Pull Station VERIZON GREENPORT VACANT EQUIP RM 19 Pull Station A22P19 N0L1 M19 Pull Station, VERIZON GREENPORT BATTERY ROOM 20 Fire Alarm A22P20 N01-1 M20 Relay VERIZON GREENPORT COMBO CO TRIP 21. Photo/CO Detector A22P21' N01-1M21 CO MONITOR VERIZON GREENPORT CO ALARM 28 Pull Station A22P28 N01-1M28 Pull Station VERIZON GREENPORT REAR ENTRY 321 Heat Detector A27P1 NO1-1 D1 Heat(Fixed) VERIZON GREENPORT JANITORS CLOSET 322 Smoke A27P2 N01-1D2 Smoke(Photo) VERIZON GREENPORT FRONT ENTRY ABV CEILING 323 Smoke A27P3 N01-1 D3 Smoke(Photo) VERIZON GREENPORT FRONT ENTRY 324 Smoke A27P4 N01-1 D4 Smoke(Photo) VERIZON GREENPORT BATHROOM ABV CEILING 325 Smoke A27135 N01-1D5 Smoke(Photo) VERIZON GREENPORT BATHROOM 326• Duct Detector A27136 NOL1D6 Smoke(Duct P) VERIZON GREENPORT AC 313-01-01 SUPPLY 327 Smoke A27P7 NOL1D7 Smoke(Photo) VERIZON GREENPORT HVAC ROOM 328 Smoke A27P8 N01-1 D8 Smoke(Photo) VERIZON GREENPORT C.O.STORE RM 329 Smoke A271P9 N01-1 D9 Smoke(Photo) VERIZON GREENPORT AC 313-01-02 SUPPLY 330 Fire Alarm A27P10 NOL1D10 Photo/CO VERIZON GREENPORT HVAC ROOM 331 Duct Detector A27P11 N01-1 D11 Smoke(Duct P) VERIZON GREENPORT AC 340-01-01 RETURN 332 Fire Alarm A27P12 N0L1 D12 Photo/CO VERIZON GREENPORT GENERATOR ROOM 333 Heat Detector A27P13 N0L1 D13 Heat(Fixed) VERIZON GREENPORT GENERATOR ROOM 334 Fire Alarm A27P14 N0L1 D14 CO Alarm VERIZON GREENPORT HALL TO BATT RM 335 Smoke A27P15 N0L1 D15 Smoke(Photo) VERIZON GREENPORT VACANT EQUIP RM 336 Smoke A27P16 N01_11316 Smoke(Photo) VERIZON GREENPORT LUNCH ROOM ABV CEILING 337 Smoke A27P17 NOL1D17 Smoke(Photo) VERIZON GREENPORT LUNCH ROOM . 338_ Smoke A271318 NOL1D18 Smoke(Photo) VERIZON GREENPORT MAP ROOM .339 Smoke `A27P.19 NOL1 D19. Smoke(Photo) VERIZON GREENPORT MAP ROOM ABV CEILING, 340 , Smoke A27P20 NOL1D20 Smoke(Photo) VERIZON GREENPORT COMP/,DYHRATOR RM 341 Smoke A27P21 NOL1 D21 Smoke(Photo),, VERIZON GREENPORT, COMP/DYHRADTOR RW ABV CEILING 342 Smoke A27P22 NOW D22 . Smoke(Photo) VERIZON GREENPORT TOLL TRANSMISSION 343'.; Smoke A271323 NOL1D23 Smoke.(Photo), VERIZON GREENPORT TOLL TRANSMISSION', 344 Smoke A27P24 . NOL1D24 Smoke(Photo) VERIZON.GREENPORT- TOLL TRANSMISSION 345 Smoke A271325 NOL1 D25 Smoke(Photo)- VERIZON GREENPORT TOLL TRANSMISSION, 346 Smoke i A271326 NOL1D26 Smoke(Photo) VERIZON GREENPORT TOLL.TRANSMISSION 347,-` Smoke A27P27.. NOL1 D27 : Smoke,(Photo)- VERIZON'GREENPORT TOLL TRANSMISSION 348 Smoke A27P.28 - NOL1D28 Smoke(Photo) VERIZON GREENPORT-... CO 5,ESS SW .. 349--. - Smoke.. A27P29 NOL1 D29 Smoke_(Photo) VERIZON GREENPORT CO 5 ESS SW 350 Smoke A27P30 NOL1D30 Smoke(Photo)- VERIZON GREENPORT CO 5 ESS'SW 351.. Smoke A27P31- NOL1D31 Smoke(Photo), VERIZON GREENPORT CO 5 ESS SW , 352 Smoke A27P32: NOL1 D32 Smoke(Photo) VERIZON GREENPORT' CO 5 ESS SW _ 353 . Smoke A27P33, NOL1D33- 'Smoke(Photo) VERIZON GREENPORT CO 5 ESS SW 354 Smoke -, A27P34 NOL1 D34 Smoke(Photo)- VERIZON GREENPORT CO 5 ESS SW 355 . Smoke A27P35 NOL1D35 Smoke(Photo) VERIZON GREENPORT , CO 5 ESS'SW 356 = Smoke A271336 . NOL1D36 Smoke(Photo) VERIZON GREENPORT C01-5_ESS'SW . 357 Smoke A27P37. NOL1D37 Smoke(Photo) VERIZON GREENPORT BATTERY/POWER HALL 358 -, Smoke A27P38 NOL1 D38. Smoke(Photo) VERIZON GREENPORT, BATTERY/POWER HALL 359 Smoke A27P39: N01_11339 Smoke(Photo) . VERIZON'GREENPORT BATTERY/POWER RM. 360 ' Smoke A27P40 NOL1D40. Smoke(Photo) ` VERIZON GREENPORT - BATTERY/POWER RM 361 .. - Smoke A271341 _ NOL1D41 Smoke(Ph'oto) VERIZON GREENPORT BATTERY/POWER RM 362 Smoke A27P42 NOL1D42 Smoke(Photo) VERIZON GREENPORT - MDF RM - 363 Smoke A27P43. NOL1D43, Smoke(Photo) VERIZON GREENPORT MDF RM , 364 _ Smoke,.--.' > A27P44,.: NOL1,D44 Smoke(Photo)` VERIZON GREENPORT MDF.RM 365. : = Smoke A271345 NOL1D45 Smoke(Photo) VERIZON GREENPORT MDF RM. 366 Smoke A27P46- - NOL1D46 Smoke(Photo) VERIZON GREENPORT. MDF RM, 367 Smoke A27P47 NOL1D47 Smoke(Photo) VERIZON GREENPORT MDF RM 368 Smoke. A271348. NOL1D48. Smoke.(Photo)., IVERIZON GREENPORT' MDF RM, 0- 2 2 CONSULTING ENGINEERS March 10,2023 Chief Building Inspector Building Department Town of Southold 54375 Route 25,P.O.Box 1179 Southold,N.Y. 11971 1 re: Fire Alarm System Upgrades Verizon Cutchogue and Greenport C.O's Main Road Southold,N.Y. 11971 Dear Mr.Verity: This letter will confirm my discussion with your office that the installation of smoke detectors in the battery rooms at the above locations is acceptable and in accordance with the 2020 New York Fire Code, Section 1206.12.4. Additionally,please be advised that the fire alarm upgrade has been designed in accordance with NFPA 72,version 2016. We trust this satisfies your concerns. Should you require further information,please do not hesitate to contact the undersigned. Thank you for our attention to a /y y this tier. ° Y sVery truly yours, R.sp Emtec Consulting En .. o a53`456 tin: ew R.; .olano,P.E. RoFEssioNv cc: Mathew Martinez: Mathew:mart riez0aee_azn.6m, Rick Winner: ' winner ns=arch:eom 3555 Veterans Memorial Highway,Suite M,Ronkonkoma,NY 11779 Phone: 631-981-3990 Fax: 631-981-3971 www.emtee-engineers.COM 1 T Visser III, Fredric From: JD <Jdoherty@commanderelectric.com> Sent: Tuesday, October 17, 2023 3:55 PM To: JD Cc: Buchenhain, Karl; McDonagh,James; Bill Schaefer; gkopylov@afap.com;Jason Marrero; Tom Murphy;lames Subject: RE: Code Review for Generator shutdown-NYS Building Codes Follow Up Flag: Follow up Flag Status: Flagged All please see the determination from the design engineer in writing below in this email as requested. Blind copied here are the Fire Marshal offices of • Town of Huntington • Town of Brookhaven • Town of Southold • Town of East Hampton • (Town of Southampton • Village of East Hampton • Town of Riverhead • Village of Westhampton Beach • Village of Shoreham • Village of Port Jeff If any FM requires Commander to resubmit the sequence of operations because of the designers determination below, please reach out to me privately. Otherwise I will submit this change on my As-builts and have them available when we coordinate your final inspection I will renew any permits as needed. Thank you Thank you, James Doherty VP Of Operations Commander Electric 500 Johnson Ave Bohemia, NY 11716 Cell (631)873-9437 Tel. (631)563-3223 EXT 114 Fax.(631)563-8322 Email:Jdoherty@commanderelectric.com 1 From: McDonagh,James<James.McDonagh@aecom.com> Sent:Tuesday, October 17,2023 2:25 PM To:JD<Jdoherty@commanderelectric.com> Cc: Buchenhain, Karl<Karl.Buchenhain@aecom.com>; Bill Schaefer<bschaefer@commanderelectric.com>; gkopylov@afap.com;Jason Marrero<jmarrero@afap.com> Subject: FW: Code Review for Generator shutdown-NYS Building Codes JD—please see email string below, with determination from the design engineer(Andrew Solano from Emtec Consulting Engineers). In an interest to continue to streamline things, please distribute to the local jurisdictions that you have already began communicating with. Thank you, James McDonagh Senior Project Manager,Tishman Cell: 646.291.0114 a ames.mcdonagh(cDaecom.com AECOM aecom.com Delivering a better world Linkedln I Twitter I Facebook I Insta4ram From: Rick Winner<r.winner@ns-arch.com> Sent:Tuesday, October 17,2023 2:19 PM To: McDonagh,James<James.McDonaeh@aecom.com> Cc:James Dawson<iames.dawson@verizon.com>;Smith,Willie (Newark) <William.Smith3@aecom.com>; Paul Gartelmann<p.eartelmann@nsarchitects.com>;Anna Lausev<a.lausev@ns-assoc.com> Subject: FW: Code Review for Generator shutdown-NYS Building Codes James, No NY State Codes require generator shutdown. This should suffice satisfying local authorities. If you have any questions, please let me know. Thanks, Rick Sincerely, Richard P.Winner.AIA Principal IEN.rS C.HICK iILVERX1 TN 631 563 2130 ext 18 Tel 516-375-3558 Cell 2 r.winnerCaD-ns architects.com NEMSCHICK SILVERMAN ARCHITECTS 1 66 EAST MAIN STREET .1 PATCHOGUE, NEW YORK 11772 1 631 563 2130 1 631 563 2139 1 www.nsarchitects.com This e-mail and any attached files are intended solely for the use of the individual or entity to which this mail is addressed and may contain information that is privileged, confidential and exempt from disclosure under applicable law.Any use, disclosure, copying or distribution of this e-mail or the attached files by anyone other than the intended recipient is strictly prohibited. If you have received this e-mail in error, please notify the sender by reply e-mail and delete this e-mail and any attached files from your system.Thank you. From:Andrew R.Solano, P.E.<asolano@emtec-engineers.com> Sent:Tuesday, October 17,2023 12:38 PM To: Rick Winner<r.winner@ns-arch.com> Cc: Piotr Koprowski, P.E. LEED GA<pkoprowski@emtec-eneineers.com> Subject: Code Review for Generator shutdown-NYS Building Codes Rick: As requested, we reviewed the following applicable NYSB Codes with respect to the question of whether the generator is required to be shutdown in the event of an activated fire alarm detection device in the generator room. Our findings are as follows: The 2022 NYS Building Code, Chapter 27—"Electrical"does not call for any shutdown requirement. Under Section(F)2702.4 "Maintenance", the Building Code references that standby and emergency power systems are to be maintained and tested in accordance with the NYS Fire Code. The 20201ire Code of NYS makes no reference to generator requirement for shutdown. The 2020 NYS Mechanical Code makes no reference to generator shutdown. Under Chapter 13, Fuel Oil Piping and Storage,there are also no requirements fo'r fuel shut in the event of activation of the fire alarm detection system. The 2016 NYS Emergency and Standby Power Code makes no reference to generator shutdown. NFPA 37-"Stds.For Installation and Use of Combustion Engines...", Chapter 11 only refers to NFPA 70 and 72. Of particular note, Sections 11.3.3.1 and 11.3.4.1 have provisions that, if detectors in the generator room are activated,the mechanical ventilation and fuel stops (where required by other Codes) can remain operational for engines providing emergency use. This could be interpreted as applicable to the CO buildings considering their importance to maintain communication in emergency situations. NFPA 72-National Fire Alarm and Signaling Code only provides direction as to how to implement the requirements designated in other Codes. n su, anion, c find na require .e i, any o 'the abo Codes that sped cal► 1 © bh e a ar u 1 to shin d n o aci a 'o o sm t o al o a e de ector h e e a or oa, . This said,the final decision rests with the Local AHJ(Fire Marshal),who can require shutdown, and this would override any of the above arguments. 3 Please advise if you have any further questions. Andy Andrew R. Solano, P.E. CEO I President C: 516.680.1277 1 O: 631.981.3990 x 223 Email: asolano@emtec-engineers.com 3555 Veterans Memorial Hwy, Suite M I Ronkonkoma,NY 11779 m tmac CONSULTING ENGINEERS,DPC MECHANICAL I ELECTRICAL I PLUMBING I FIRE ALARM I FIRE PROTECTION I COMMISSIONING This message is intended only for the personal and confidential use of the designated recipient(s)named above.This is not in any way an official statement of Emtec Consultants or solicitation to buy our services.Emtec Consultants does not guarantee this Email transmission to be secure or error-free.If you are not the intended recipient,please notify the sender by reply email and permanently delete all copies of the original niessage with all attachments. 4 2MI: 20 , CONSULTING ENGINEERS MAR 16 2nn 7 --S- 1 1 , March 10,20230 Chief Building Inspector • 1 Building Department 6 P 418 �13 Town of Southold 54375 Route 25,P.O. Box 1179 Southold,N.Y. 11971 re: Fire Alarm System Upgrades Verizon Cutchogue and Greenport C.O's Main Road Southold,N.Y. 11971 Dear Mr. Verity: This letter will confirm my discussion with your office that the installation of smoke detectors in the battery rooms at the above locations is acceptable and in accordance with the 2020 New York Fire Code, Section 1206.12.4. Additionally,please be advised that the fire alarm upgrade has been designed in accordance with NFPA 72,version 2016. We trust this satisfies your-concerns. Should you require further information,please do not hesitate to contact the undersigned. Thank you for your attention to this atter. OFNEWY Very truly yours, ��`� �� R. so o,�g Emtec Consulting Eng' �yo Q \� Ce Uj H n W s �53455 Q. An R.ew olano, P.E. 0°'RaFE3451b cc: Mathew Martinez: Mathew.martinezgaecom.com Rick Winner: r.winnerna,ns-arch.com 3555 Veterans Memorial Highway,Suite M,Ronkonkoma,NY 11779 Phone: 631-981-3990 Fax: 631-981-3971 www.emtee-engineers.com E t . ti Suffa.IkCoun' De - :. . :. Labor:: censi.ng &:C:onsumer'A;�fairs; }' MASTEF {'ELE.CTR10AL tip A Name . :: B:usiness:;Narriek �:"hNs c0'ifie-0 that=tt e- _ . TR[C"INC?eaer.is cu,fy lcersecJ; C4tVItv1ANDEFZ ELEC; °�y:�hg'Count_y;of�suffolk . - - - L �cense=:`Number:° ME=50:062' Rosalie:Urago; sued 0 C:anir�issiarier -. - { Expires:. 0:410�1°l2024 rer This license is the property of Suffolk County Department of Labor, Licensing & Consumer Affairs. .;' Possession of this license hoes not guarantee its validity. Additional Business Name License Category A YOUR FIRE AND SECURITY SOLUTION 155 Michael Drive Syosset, NY 11791 PH:516-496-2322 LIC#12000300939 SCOPE OF WORK: In Reference to Verizon at 74785 Main Road, Greenport, NY 11944. We will be installing a new Full Fire Alarm system with Aspiration detection. Once approved to do so, Commander Electric will have a crew install the system. Once they are finished, we will schedule an AFA programmer to program and Test all the devices for proper functionality. We will install and program as per 2020 Building Code of New York State; "' v �ire Coc`c­of. New York-State, NFPA Standard 72 2016 edition, NFPA 70 NEC 2017, Code of the Town . of Southold, 2020 Mechanical Code of New York State, and manufacturer's Installation Instructions. Detailed Activity Report 410r, k2S Date Range: 3/13/202410:15 - 3/13/202410:45 Account Group: System#: 4351808 Verizon#32212 (Fire System) 74785 Main Rd Greenport,NY 11944 Account# 4351808 Day Date Event/Operator Action Opr User User Name Signal Area Zone Zone Description Comment Wed 03/13/2024 10:18:17AM *S Ell -FIRE ALARM- E115 0 1 Front Entry Pull PULL STATION Station Wed 03/13/2k2 f 10:23:07AM 'S E300-SYSTEM TROUBLE -;. E300 0 TO _ _._. Wed 03/13/2024 10:23:15AM *S R115-RESTORAL-PULL R115 0 1 Front Entry Pull STATION Station Wed 03/13/2024 10:23:15AM *S E321 -BELL 1 TROUBLE - - E321 0 TO Wed 03/13/2024 10:23:35AM *S R300-RESTORAL- R300 0 TO SYSTEM TROUBLE Wed 03/13/2024 10:23:44AM *S E300-SYSTEM-TROUBLE " _._ E300 0 TO j Wed 03/13/2024 10:25:56AM *S Ell -FIRE ALARM- E111 0 325 Bathroom Smoke SMOKE DETECTOR Detector Wed`-03/13/2024 10:26:07AM *S R321 -RESTORAL-BELL • 1 Wed 03/13/2024 10:26:07AM *S R300-RESTORAL- R300 0 TO SYSTEM TROUBLE _ Wed 03/13/2024 10:26:52AM :- *S E11'5-FIRE ALARM- " E115 0 28 Rear.Entry Pull Station PULL STATION Wed 03/13/2024 10:27:53AM *S E111 -FIRE ALARM- E111 0 340 Comp/Dyhrator Rm SMOKE DETECTOR Smoke Detector Wed ,03/13/2024 10:28:41AM- *S E111 -FIRE ALARM- E111 0 . 368 ' Mdf Rm Smoke SMOKE DETECTOR Detector. Wed 03/13/2024 10:29'A1AM *S E__1-1,1 FIRE ALARM- E111 0 338 Map Room Smoke SMOKE_DETECTOR Detector Wed 03/13/2024-•10:30:36AM "S E111 -FIREALARM- E111 -0' 345 Toil Transriissiorr V -- -- - - - - - SMOKE DETECTOR •Smoke Detector-- - -- -------=- - -- . 11:01:27AM 3/13/2024 Page 1 of 4 c Detailed Activity Report Date Range: 3/13/202410:15 - 3/13/202410:45 Account Group: System#: 4351808 Account# 4351808 „ Day Date Event/Operator Action Opr User User Name Signal Area Zone Zone Description Comment Wed 03/13/2024 10:31:22AM *S E115-FIRE ALARM- E115 0 19 Battery Room Pull PULL STATION Station iNed 03/13/2024 10:32:04AM *S E111 -FIREALARM= E111 0 360v -Battery/Power Rm SMOKE DETECTOR =__ -_ .. Smoke Detector Wed 03/13/2024 10:33.16AM *S E115-FIRE ALARM- E115 0 18 Vacant Equip Rm Pull PULL STATION Station_ Wed 03113/2024 10:33:40AM, 'S E111 -FIRE ALARM- E111 .0 m:337' Lunch Room,Smoke = _ SMOKE _ _•Detector' y� Wed 03/13/2024 10:34:46AM *S E114-FIRE ALARM- E114 0 333 Generator Room Heat HEAT DETECTOR Detector 13/20210:35:34M EWed . 332. eneratorRoom Weds03/13(2024 10:3544AM *SR115-RESTORAL-PULL R115 0-—18 Vacant Equip Rm Pull STATION Station Wed, 03/13/2024 10:35:44AM *S E321 -BELL,1 TROUBLE . b3 _i 0 TO" Wed 03/13/2024 10:35:44AM *S E300-SYSTEM TROUBLE E300 0 TO Wed 03(13/2024 10:35:50AM' *S R115-,RESTORAL-PULL, R115 ' '0 .419 Battery Room Pull STATION' Station ' Wed 03/13/2024 10:35:50AM *S R115-RESTORAL-PULL R115 0 28 Rear Entry Pull Station STATION Wed,03/13/2024 10:35:50AM *S R111 -RESTORAL- R111 ,. '0: 325 'Bathroom Smoke SMOKE DETECTION; Detector Wed 03113/2024 10:36:OOAM *S!REST-RESTORAL-(Log R110 0 332 Generator Room Wed 03/13/2024 10:36:OOAM `S R114-_RESTORAL-HEAT R114 0 : 333 .. Generator Room Heat ,. DETECTION Detector _ _.___---._ _-._ 'DETECTION, -__ -__—._-__-_-- -- __ _ Wed 03(13/2024 10:36:OOAM *S R111 -RESTORAL- R111 0 337 Lunch Room Smoke SMOKE DETECTION Detector Wed 03/13/2024 10:36:OOAM- *S.R111 -RESTORAL- R111 0; 338 Map Room Smoke _.SMOKE^DETECTION Detector Wed 03/13/2024 10:36:11AM *S R111 -RESTORAL- R111 0 340 Comp/Dyhrator Rm SMOKE DETECTION Smoke Detector 11:01:27AM 3/13/2024 Page 2 of 4 Detailed Activity Report Date Range: 3/13/202410:15 - 3/13/202410:45 Account Group: System M 4351808 Account# 4351808 Day Date Event/Operator Action Opr User User Name Signal Area Zone Zone Description Comment Wed 03/13/2024 10:36:11AM *S R111 -RESTORAL- - R111 0 345 - Toll Transmission { --•SMOKE DETECTION ---- -=-__-_•-._. _ _ _._ . .__ ._:_-_-----------__.__----___--- Smoke Detector Wed 03/13/2024 10:36:11AM *S R111 -RESTORAL- R111 0 360 Battery/Power Rm - - - SMOKE DETECTION Smoke Detector Wed 03/13/2024 10:36:41AM *S C01 -CARBON E162 0' 21 Carbon Monoxide MONOXIDE ALARM___ Alarm Wed 03/13/2024 10:36:56AM *S R111 -RESTORAL- R111 0 368 Mdf Rm Smoke SMOKE DETECTION Detector Wed. 03/13/2024 .10.:36:56AM,• .'*S.R300-RESTORAL- R300 0 :TO -- - -- - = - SYSTEM-TROUBLE_---..._.._,n Wed 03/13/2024 10:36:56AM *S E300-SYSTEM TROUBLE E300 0 TO Wed 03/13/2024 10:37:55AM *S E110-FIRE ALARM E110 0 9 Generator Rm Flame Detector Monitor' Wed 03/13/2024 10:38:34AM *S R321 -RESTORAL-BELL R321 0 TO Wed 03%13/2024 10:38:34AM *S R300-.RESTORAL- R300 0 TO - ,1 t- - - --- - - -= - SYSTEM TROUBLE-- _ Wed 03/13/2024 10:40:09AM *S Ell-FIRE ALARM E110 0 330 Hvac Room Wed 03/13/2024'10:40:17AM .*S R110-RESTORAL-FIRE R110 - 0 9 Generator Rm Flame Detector Monitor Wed 03/13/2024 10:40:17AM *S E321 -BELL 1 TROUBLE E321 0 TO Wed 03/13/2024 10:40:17AM *S E300,-SYSTEM TROUBLE E300 0 - TO- Wed 03/13/2024 10:40:27AM *S!REST-RESTORAL-(Log R110 0 330 Hvac Room Only) Wed 03%13%2024 10:40:27AM *S!REST-RESTORAL-(Log . R162 0 21 Carbon Monoxide Onl Y.)__ _ - - ---------- - --- =---..-- ------ -- ----- -- ------ -____—__._ arm , -' - - --- - - --- ---- - ----- Wed 03/13/2024 10:40:41AM *S R300-RESTORAL- R300 0 TO SYSTEM TROUBLE Wed 03/13/2l624-10:40:50AI ' *S E300-SYSTEM TROUBLE . E300 Wed 03/13/2024 10:44:12AM *S E111 -FIRE ALARM- E111 0 323 Front Entry Smoke SMOKE DETECTOR Detector 11:01:27AM 3/13/2024 Page 3 of 4 Detailed Activity Report Date Range: 3/13/202410:15 - 3/13/202410:45 Account Group: System M 4351808 Account# 4351808 Day Date Event!Operator Action Opr User User Name Signal Area Zone Zone Description Comment Wed 03/13/2024 10`.44:23AM *S R321 =RESTORAL-BELL - R321 0 ; TO Wed 03/13/2024 10:44:23AM *S R300-RESTORAL- R300 0 TO SYSTEM T_ ROUBLE 'S E300=SYSTEM TROUBLE E300 0. TO Wed' 03/13%2024 10:44:57AM - - - —--- - - - _ -_ --------- �- - ._.__.. .. ...- - - - ------ Wed 03/13/2024 10:45:05AM *S R111 -RESTORAL- R111 0 323 Front Entry Smoke SMOKE DETECTION Detector Wed 03/13/2024 10:45:05AM *S-E321 -BELL 1 TROUBLE . E321 Wed 03/13/2024 10:45:23AM *S R300-RESTORAL- R300 0 TO SYSTEM TROUBLE Wed 03/13/'2024 1 d:45:32AM *S bo-O-SYSTEM TROUBLE _ E300 ' -0- TO ' ___.. ..__ - .---.-.._-.- -----.____ __ _-. -- _ ---_.._•_..-----_.._..___ 11:01:27AM 3/13/2024 Page 4 of 4 Detailed Activity Report Date Range: 2/21/2024 08:00 - 2/21/2024 09:00 Account Group: System#: 4351808 Verizon#32212 (Fire System) 74785 Main Rd Greenport,NY 119" Account# 4351808 Day Date Event Operator Action Opr User User Name Signal Area Zone Zone Description Comment Wed 02/21/2024 08:05:26AM *T External User-Place on Buckmaster, Robert All Points No Action 8 Hours- Test Expires:Feb 21,2024 4:05:OOPM-iOS RM App-Account Test Wed'02/21/2024 0&10:33AM, . *T E110-FIRE ALARM - - -E110'- _0 1 - . -Font-Entry Wed 02/21/2024 08:11:24AM *T E300-SYSTEM TROUBLE E300 0 TO Wed 02/21/2024 08:11:34AM` *T R110-_R_E_STO_RAL-FIRE _ - W -_R110 0 1 -l Front Entry ed 02/21/2024 08:11:54AM- *T R300-RESTORAL- - R300 0 TO SYSTEM TROUBLE Wed 02/21%2024 08:14:04AM *T E111 FIREALARM E111 : 0 • -323 Front Eritry Smoke' SMOKE DETECTOR: --..._v_ _ Detector Wed 02/21/2024 08:16:46AM *T E300-SYSTEM TROUBLE E300 0 TO Wed. 02%21/2024 08:16:56AM *T R111 -RESTORAL- R11T 0 Front Entry Smoke ---- - ------ =----- SMOKE DETECTION ---- -_------- - ----=----_--- ---- _Detector 1 Wed 02/21/2024 08:17:16AM *T E110-FIRE ALARM E110 0 330 HVAC Room Wed 02/21/2024 08:17:24AM *T IREST-RESTORAL-.(Log = R110 0 -330� HVAC Room,. Wed 02/21/2024 08:17:24AM *T R300-RESTORAL- R300 ~0 TO SYSTEM TROUBLE Wed .02/21/2024 '08:17:24AM. _*T E_30_0-.S_YS_TEM TROUBLE E300 0 TO Wed 02/21/2024 08:18:OOAM *T R300-RESTORAL — ^ ` R300 0 TO SYSTEM TROUBLE Wed 02/21/2024 08:19:59AM - - - - - - - - -- T E300-SYSTEM TROUBLE E3� � � .E300 0 T0. Wed 02/21/2024 08:20:27AM *T R300-RESTORAL- R300 0 TO SYSTEM TROUBLE 3:00:27PM 2/21/2024 Page 1 of 3 Detailed Activity Report Date Range: 2/21/2024 08:00 - 2/21/2024 09:00 Account Group: System#: 4351808 Account# 4351808 Day Date Event/Operator Action Opr User User Name Signal Area Zone Zone Description Comment Wed 02/21/2024 08:21:12AM *T.E111 -FIREALARM_ E111- O. 338. Map'Room-Smoke SMOKE DETECTOR _Detector Wed 02/21/2024 08:23:43AM *T E300-SYSTEM TROUBLE E300 0 _ TO - Wed 02/21/2024 08.m:54AM *T R111.:RESTORAL- - R111 0 338 .Map Room Smoke SMOKE DETECTION _ �i__ Detector Wed 02/21/2024 08:24:12AM- *T R300-RESTORAL- R300 0 TO SYSTEM TROUBLE ed:02/21/2024 08:25:23AM *T E111 -FIRE ALARM= .E11i 0' 340 Com - - -- - -"; W _Como SMOKE DETECTOR- _-.--- Room SmokeDetector Dete ___: __ Wed 02/21/2024 08:26:02AM *T Ell -FIRE ALARM- E111 0 366� MDF Room Smoke- SMOKE DETECTOR _ _ Detector _ Wed.,02/21/20-24 08:28:09AM *T E111 -FIRE ALARM E111- -0 345 Toll Transmission- SMOKE DETECTOR. Smoke Detector Wed 02/21/2024 08:28:35AM *T E300-SYSTEM TROUBLE E300 0 TO Wed 02/21/2024.08:28:45AM - *T R111 -RESTORAL-- R111 10. 340 Comp/Dehydrator ' .-.SMOKE DETECTION Room Smoke Detector. Wed 02/21/2024 08:28:45AM *T R111 -RESTORAL- R111 0 345 Toll Transmission SMOKE DETECTION Smoke Detector Wed `02121/2024'08:28:45AM *T R111 -RESTORAL- _ R111, 0 366 MDF Room Smoke SMOKE DETECTION Detector ? Wed 02/21/2024 08:29:01AM *T R300-RESTORAL- R300 0 TO SYSTEM TROUBLE Wed 02/21/2024 08:29:40AM '*T.E111 -FIRE ALARM- E111 0. 354 CO 5 ESS SW Smoke SMOKE DETECTOR -- ------- - :. --- --- —_ --- -- Detector — Wed 02/21/2024 08:31:17AM *T E111 -FIRE ALARM- E111 0 360 Battery/Power Room SMOKE DETECTOR Smoke Detector Wed 02/21/2024 08:52:18AM• *T E110-FIRE ALARM E110 -0 9. Generator Room ,1 ----- ------ ---- - -----_ - - - _ - -_- _ _- - -- -=- - -- ----- _ Flame Detector y---- ----------- I Wed 02/21/2024 08:53:09AM *T E300-SYSTEM TROUBLE E300� 0 TO Wed. 02/21/2024 0853:19AM *T R110-RESTORAL-FIRE' R110. 0 9 Generator Room - -- - - Flame Detector _ 3:00:27PM 2/21/2024 Page 2 of 3 Detailed Activity Report Date Range: 2/21/2024 08:00 - 2/21/2024 09:00 Account Group: System M 4351808 Account# 4351808 Day Date Event/Operator Action Opr User User Name Signal Area Zone Zone Description Comment Wed 02/21/2024 08:53:19AM *T R111 -RESTORAL- R111 0 354 CO 5 ESS SW Smoke SMOKE DETECTION Detector Wed 02/21/2024 08:53:19AM *T R111 -RESTORAL- '. R111 0 360 Battery/Power Room ' SMOKE DETECTION- Smoke Detector.- Wed 02121/2024 08:53:38AM *T R300-RESTORAL- R300 0 TO SYSTEM TROUBLE 3:00:27PM 2/21/2024 Page 3 of 3 - F r k Verizon 74785 Main Road Greenport- Battery Calculation Report PANEL INFORMATION PanetType NFS-320 ... ....... ...... No.of Loops I No.of Devices 88 Status 0 PASS BATTERY&CHARGER REQUIREMENT Normal, 24 Hours i Operation BAT-12120 12Ah 11.934Ah ........................ In Alarm 5 Mins g Suggested Battery I Suggested Capacity Required Capacity Required Standbytime(in Hours) Required In Alarm time0n Mins) ta Sndby Lc id CurnA,�,, x P;ne(in (111 haul'&) In Alf)-,M Lrj2d Ctirre;IiWn AMW x 0.412 '.24 .9.888 Ah 0.666 O.083(Smlns) =0,057Ah ........... ............. ........... .. ....................... . ............... Total Current Load - 9.94SAh Multiply with Berating factor w x1.2 Adding with spare capacity - N/A Total AH required - 11.934 Ah LOOPI DETAILS Loops 225 23,,nA Consumed I """;.... .. Number of devices 67 PANEL MODULES No.of Modules 21 a727,3% 0% CPU-320 1 250 250 No of NACs in use 2 70 70 ACM-24AT 1 16 70 LEDs ON(ACM/AE&I-24/46) 1 5.4 0 UDAC32Communicator 1 52 87 ESL 100 UV IR 1 0,03 0.08 MR201CR 5 0 0,17 RA100Z 5 0 0.05 SCWL CLR ALERT 3 0 019 EOLR1 1 0 0.02 Loop Details uf:;a.�a} t t°": F '.P'' a"A"••a• .hi:•. tea. . ffi FSP-951 20 02 4.5 FSV-951R 20 03 0.45 FCO-951 2 0.2 0,45 FSCD-951 1 0.2 0.45 NSG12LX 4 0.375 0.375 FCM-1 3 0.485 6.5 FMM-1 6 0,35 5 FM M-101 1 0.35 0.6 FSP-951R 3 0,2 4.5 FRM-1 5 0.255 6.5 FST-951 2 0.2 4.5 NAC CIRCUITS xRr awn NAC Circuit 1 1.026 0 NAC Circuit 2 OJ29 0 NAC Circuit 3 0 0 NAC Circuit 4 0 0 BATTERY SHARING 9 OW gnaw Battery Sharing 1 0 0 Battery Sharing 2 0 0 Battery Sharing 3 0 0 Battery Sharing 4 0 0 Battery Sharing 5 0 0 M nqaywtall THE F.1--......- r Verizon 74785 Main Road Greenport-Voltage Drop Calculation Report POWERSOURCE Power NFS-320(4 NAC)CLASS B I Brand Notifier UL I Model NFS-320(4 NAC)CLASS B I Nominal 20.4 VOLTS Source Number System Voltage CIRCUIT 1 NAC Circuitl I 1.026 AMPS i CLASS B I AWG I it Devices I 1.026 AMPS USED I 0.72 VOLTAGE DROP # Device Model Candela Pattern Volume Tone CURRENT(AMPS) Dist fromprevdevice Volts 1 P2RK 75 Temporal High Electromechanical 0.176 22 20.4 2 P2RL 30 Temporal High Electromechanical 0.074 29 20.25 3 P2RL 75 Temporal High Electromechanical 0.121 27 20.11 4 P2RL 30 Temporal High Electromechanical 0.074 10 20.07 5 P2RL 30 Temporal High Electromechanical 0.074 21 20 6 P2RL 75 Temporal High Electromechanical 0.121 25 19.92 7 P2RL 30 Temporal High Electromechanical 0.074 37 19.83 8 SRL 15 0.043 24 19.78 9 P2RL 30 Temporal High Electromechanical 0.074 34 19.72 10 P2RL 30 Temporal High Electromechanical 0.074 22 19.7 11 P2RL 75 Temporal High Electromechanical 0.121 17 19.68 CIRCUIT 2 NAC Circuitl I 0.729 AMPS I CLASS B I AWG I 9 Devices I 0.729 AMPS USED I 0.4 VOLTAGE DROP # Device Model Candela Pattern Volume Tone CURRENT(AMPS) Dist from prev device Volts 1 P2RL 30 Temporal High Electromechanical 0.074 12 20.4 2 P2RL 30 Temporal High Electromechanical 0.074 15 20.34 3 SRL 15 0.043 14 20.29 4 P2RL 30 Temporal High Electromechanical 0.074 14 20.24 5 P2RL 75 Temporal High Electromechanical 0.121 42 20.12 6 P2RL 30 Temporal High Electromechanical 0.074 17 20.08 7 P2RL 30 Temporal High Electromechanical 0.074 12 20.06 8 P2RL 30 Temporal High Electromechanical 0.074 27 20.03 9 P2RL 75 Temporal High Electromechanical 0.121 39 20 CIRCUIT 3 NAC Circuit3 I 0 AMPS I CLASS B I AWG I 0 Devices 10 AMPS USED I D VOLTAGE DROP # Device Model Candela Pattern Volume Tone I CURRENT(AMPS) Dist from prev device Volts CIRCUIT 4 _a NAC Circuit4 I 0 AMPS I CLASS B I AWG I 0 Devices 10 AMPS USED 10 VOLTAGE DROP # Device Model Candela Pattern Volume Tone I CURRENT(AMPS) Dist from prev device Volts' i AFA Protective Systems,Inc. 155 Michael Drive ® Syosset, NY 11791 Licensed by the N.Y.S. Department of State- NYS License#12000300939 YOUR FIRE AND SECURITY SOLUTION FIRE ALARM SUBMITTAL for Verizon — Greenport 74785 Main Road Greenport, NY 11944 FIRE ALARM Contractor: Commander Electric, Inc. 500 Johnson Avenue Bohemia, NY 11716 (631) 563-3223 Fire Alarm Vendor: AFA Protective Systems 155 Michael Drive Syosset, NY 11791 (516) 496-2322 Sales Representative: Gene Kopylov (212) 279-5000 Project Manager: Joseph Cassone (516) 315-0273 General Manager: Scott Harris (212) 279-5000 Date: October 20, 2022 A A YOUR FIRE AND SECURITY SOLUTION FIRE ALARM SUBMITTAL PREPARED FOR Verizon — Greenport TABLE OF CONTENTS DESCRIPTION: SECTION Fire Alarm CUT SHEETS 1 Fire Alarm Battery Calculations and Drawings 2 VESDA Bill of Material and Data Packet 3 , YOUR FIRE AND SECURITY SOLUTION FIRE ALARM SUBMITTAL PREPARED FOR Verizon — Greenport BILL OF MATERIALS QTY Description Page 1 NFS-320 CONTROL PANEL 1 1 IPGSM-4G COMMUNICATOR 7 1 UDACT 2 DUAL LINE MODULE 10 1 ACM-24AT ANNUNCIATOR CARD 12 2 12V 12 AH BATTERY 16 0 12V 7 AH BATTER 16 0 LCD2-80 ANNUCIATOR) 19 0 PSE-10 POWER SUPPLY 21 13 FSP-951 SMOKE DETECTOR 23 3 FSP-951 R SMOKE DETECTOR FOR DNR 23 2 FST-951 HEAT DETECTOR 26 15 B300-6(MOUNTING BASE (SMOKE DETECTOR)) 29 3 DNR DUCT HOUSING 32 3 DST-5 SAMPLING TUBE 32 5 RA 100Z REMOTE LED 34 1 FSL-100-UV/IR FLAME DETECTOR 36 2 FCO-951 CARBON MONOXIDE/SMOKE DETECTOR COMBO 44 1 FSCO-951 CARBON MONOXIDE DETECTOR 46 3 B20OS-WH SOUNDER BASE 48 4 FMM-1 (MONITOR MODULE) 52 1 FMM-101 (MINI MONITOR MODULE) 52 6 FDM-1 DUAL MONITOR MODULE 52 4 FRM-1 RELAY MODULE 56 3 FCM-1 CONTROL RELAY 56 4 MR-201 (RELAY) 58 4 NBG-12LX MANUAL PULL 60 4 SB-10 BACK BOX PULL STATION 60 1 EOLR-1 End of Line 24V Supervisory Relay) 62 17 P2RL HORN STROBE ALL 64 2 SRL STROBE ALL 64 0 SCRL STROBE (CELING)) 68 0 PC2RL HORN STROBE CEILING 68 3 SCWL-CLR-ALERT CO STROBE CEILING 68 1 P2RK HORNSTROBE EXTERIOR (BACKBOX INCLUDED) 72 19 SBBRL BACK BOX ALL (RED H/S-STROBE) 76 0 SBBCRL BACK BOX CEILING RED H/S-STROBE 76 3 SBBCWL BACK BOX CEILING (WHITE H/S—STROBE) 76 3 LENS-AC2 AMBER LENS FOR CEILING CO STROBE) 77 1 KNOX BOX 3200 81 3 VEP-A10-P ESDA CONTROL PANEL 83 3 VESDA-VPS-1000S ESDA POWER SUPPLY 85 Section 3 E700-SP-DCL-PNT ESDA SAMPLING PORT 87 1 SYSTEM DOCUMENT BOX 91 � A *. YOUR FIRE AND SECURITY SOLUTION Page 1 DN-7112:F2 NFS-320(E) N OTI F 1 E R° Intelligent Addressable (a Fire Alarm System by Honeywell Intelligent Fire Alarm Control Panels General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX@ Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series prod- ucts meet virtually every application requirement. I Designed with modularity and ease of system planning, the NOTIFIEW NFS-320 can be configured with just a few devices for small building applications,or networked for a large campus or high- rise application.Simply add additional peripheral equipment to suit the application. For installations using NFS-320C, an optional ACM Series annunciator can be mounted in the same cabinet (up to 48 zones/points, order separately; see DN- 60085). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two dedicated business NFS-320 telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication • Alarm Verification selection per point,with tally over the public switched telephone line. • Presignal/Positive Alarm Sequence(PAS). NOTE.Unless called out with a version-specific"R, `C"or"E"at . Silence inhibit and Auto Silence timer options. the end of the part number, NFS-320"refers to models NFS-320, NAC coding functions: NFS-320R,NFS-320C,and NFS-320E. g —March time. Features —Temporal. • Certified for seismic applications when used with the appro- —California two-stage coding. priate seismic mounting kit. —Canadian two-stage. • One isolated intelligent Signaling Line Circuit(SLC)Style 4, —Strobe synchronization. 6 or 7. • Field-programmable on panel or on PC, with VeriFire@ • Up to 159 detectors (any mix of ion, photo, thermal, or Tools program check,compare,simulate. multi-sensor) and 159 modules (Addressable pull stations, . Full QWERTY keypad. normally open contact devices, two-wire smoke, notifica- . Battery charger supports 18—200 AH batteries. tion,or relay).318 devices maximum. • Standard 80-character display. Non-alarm points for lower priority functions. • Network options: • Remote ACK/Signal Silence/System Reset/Drill via monitor modules. —High-speed network for up F 32 nodes (NFS, DVC, • Automatic time control functions,with holiday exceptions. NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, y p ONYXWorks, NFS-3030,NFS-640,and NCA). • Extensive,built-in transient protection. —Standard network for up to 103 nodes (NFS2-3030, • Powerful Boolean logic equations. NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, FLASHSCANO INTELLIGENT FEATURES ONYXWorks, NCS,NFS-3030,NFS-640, NCA,AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes • Poll up to 318 devices in less than two seconds. when DVC is used in network paging. • Activate up to 159 outputs in less than five seconds. • 6.0 A power supply with four Class A/B built-in Notification . Multicolor LEDs blink device address during Walk Test. Appliance Circuits (NAC). Selectable System Sensor, Fully digital, high-precision protocol (U.S. Patent Wheelock,or Gentex strobe synchronization. 5,539,389). • Built-in Alarm,Trouble,Security,and Supervisory relays. Manual sensitivity adjustment—nine levels. • VeriFire@ Tools online or off line programming utility.Upload/ Pre-alarm ONYX intelligent sensing—nine levels. Download,save,store,check,compare,and simulate,panel databases.Upgrade panel firmware. Day/Night automatic sensitivity adjustment. • Autoprogramming and Walk Test reports. • Sensitivity windows: • Optional universal 318-point DACT. —Ion—0.5 to 2.5%/foot obscuration. • 80-character remote annunciators(up to 32). —Photo—0.5 to 2.35%o/foot obscuration. • EIA-485 annunciators,including custom graphics. —Laser(VIEW@)—0.02 to 2.0%/foot obscuration. • Printer interface(80-columh and 40-column printers). —Acclimate@ PIusTM—0.5 to 4.0%/foot obscuration. • History file with 800-event capacity in nonvolatile memory, —IntelliQuad—1.0 to 4.0%/foot obscuration. plus separate 200-event alarm-only file. —IntelliQuadTM PLUS—1.0 to 4.00/6/foot obscuration DN-7112:F2.9W2011—Page 1 of 6 Page 1 Page 2 • Drift compensation(U.S.Patent 5,764,142). FSC-851 INTELLIQUAD • Degraded mode—in the unlikely event that the NFS-320's ADVANCED MULTI-CRITERIA DETECTOR primary microprocessor fails, FlashScan detectors revert to a Detects all four major elements of a fire (smoke, heat, CO, degraded operation and can activate the control panel's and flame). NAC circuits and alarm relay. Each of the four built-in panel • Automatic drift compensation of smoke sensor and CO cell. circuits includes a Disable/Enable switch for this feature. • Multi-detector algorithm involves nearby detectors in alarm • High nuisance-alarm immunity. decision(U.S.Patent 5,627,515). • Six sensitivity levels. • Automatic detector sensitivity testing(NFPA-72 compliant). FCO-851 INTELLIQUADTm PLUS • Maintenance alert(two levels). ADVANCED MULTI-CRITERIA F/RE(CO DETECTOR • Self-optimizing pre-alarm. Detects all four major elements of a fire. FSL-751 VIEW(VERY INTELLIGENT EARLY WARNING) Separate signal for life-safety CO detection. SMOKE DETECTION TECHNOLOGY Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO)tone. • Revolutionary spot laser design. Automatic drift compensation of smoke sensor and CO cell. • Advanced ONYX intelligent sensing algorithms differentiate . High nuisance-alarm immunity. between smoke and non-smoke signals (U.S. Patent 5,831,524). Six sensitivity levels. • Addressable operation pinpoints the fire location. RELEASING FEATURES • No moving parts to fail or filters to change. Ten independent hazards. • Early warning performance comparable to the best aspira- e Sophisticated cross-zone(three options). tion systems at a fraction of the lifetime cost. • Delay timer and Discharge timers(adjustable). FAPT-851 ACCLIMATE®PLUSTu • Abort(four options). LOW-PROFILE INTELLIGENT MULTI-SENSOR • Low-pressure CO2 listed. • Detector automatically adjusts sensitivity levels without operator intervention or programming.Sensitivity increases VOICE FEATURES with heat. • Integrates with FireVoice-25/50 Series(see DN-7004). • Microprocessor-based technology; combination photo and • Integrates via serial connection with FireVoice-25/50ZS thermal technology. Series(see DN-7003). • FlashScan or CLIP("classic")mode compatible. HIGH-EFFICIENCY OFFLINE SWITCHING • Low-temperature warning signal at 40OF t 5°F (4.44°C t 3.0 A POWER SUPPLY(6.0 A/N ALARM) 2 77-C) • 120 VAC(NFS-320/NFS-320C);240 VAC(NFS-320E). • Displays battery current/voltage on panel(with display). Up to 32 Remote Displays SLC Intelligent Loop ----- -- - - -- DEVICES o o g 0 FSC-851 IntelliQuadTM ❑ ❑ o00o F1 Acclimate PIusTM FSL-751SL-751 FlashScan®VIEW® NBG-12LX FMM-1 FRM-1 XP6/10 FDU$0 FSP-851 Flash can@ photo 1/0 Modules etc. LCD2-80 LCD2-80 IDC Relay Contact EIA-485 EIA-485 2048 annunciator/control points T ACM-8R ACWAEM-24AT LDM-32 NFS-320 Relay Control LED Annunciator Custom Graphics Optional 318 point UDACT Dual phone lines to 10 Central Station Sample System EIA-232 Options PRN Series Printer 7112blok.wmf Page 2 of 6—DN-7112:F2.91712011 Page 2 Page 3 FlashScan, Exclusive gram creation and editing capability from the front panel key- World-Leading Detector Protocol pad, while continuing to provide fire protection. The architecture of the NFS-320 software is such that each point At the heart of the NFS-320 is a set of detection devices and entry carries its own program, including control-by-event links device protocol—FlashScan(U.S.Patent 5,539,389).FlashS- to other points. This allows the program to be entered with can is an all-digital protocol that gives superior precision and independent per-point segments, while the NFS-320 simulta- high noise immunity. neously monitors other(already installed)points for alarm con- In addition to providing quick identification of an active input ditions. device, this new protocol can also activate many output VeriFireO Tools is an offline programming and test utility that devices in a fraction of the time required by competitive proto- can greatly reduce installation programming time, and cols. This high speed also allows the NFS-320 to have the increase confidence in the site-specific software. It is Win- largest device per loop capacity in the industry—318 points dows®-based and provides technologically advanced capabili- -yet every input and output device is sampled in less than ties to aid the installer. The installer may create the entire two seconds.The microprocessor-based FlashScan detectors program for the NFS-320 in the comfort of the office, test it, have bicolor LEDs that can be coded to provide diagnostic store a backup file,then bring it to the site and download from information,such as device address during Walk Test. a laptop into the panel. ONYX Intelligent Sensing Placement of Equipment Intelligent sensing is a set of software algorithms that provides in Chassis and Cabinet the NFS-320 with industry-leading smoke detection capability. The following guidelines outline the NFS-320's.flexible system These complex algorithms require many calculations on each design. reading of each detector, and are made possible by the high- speed microcomputer used by the NFS-320. Wiring: When designing the cabinet layout, consider separa- tion of power-limited and non-power-limited wiring as dis- Drift Compensation and Smoothing: Drift compensation cussed in the NFS-320 Installation Manual. allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It It is critical that all mounting holes of the NFS-320 are secured reduces maintenance requirements by allowing the system to with a screw or standoff to ensure continuity of Earth Ground. automatically perform the periodic sensitivity measurements Networking: If networking two or more control panels, each required by NFPA 72. Smoothing filters are also provided by unit requires a Network Control Module or High-Speed Net- software to remove transient noise signals, such as those work Control Module (HS-NCM can support two nodes; see caused by electrical interference. "Networking Options" on page 4). These modules can be Maintenance Warnings: When the drift compensation per- installed in any option board position(see manual),and addi- formed for a detector reaches a certain level,the performance tional option boards can be mounted in front of them. of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber KDM-R2 Controls and Indicators value; (2) Maintenance Alert, indicative of dust accumulation Program Keypad:QWERTY type(keyboard layout). that is near but below the allowed limit; (3) Maintenance Urgent,indicative of dust accumulation above the allowed limit. 12 LED Indicators: Power; Fire Alarm; Pre-Alarm; Security; Sensitivity Adjust: Nine sensitivity levels are provided for Supervisory; System Trouble; Signals Silenced; Points Dis- alarm detection. These levels can be set manually, or can abled;Control Active;Abort;Pre-Discharge;Discharge. change automatically between day and night. Nine levels of Keypad Switch Controls:Acknowledge/Scroll Display;Signal pre-alarm sensitivity can also be selected,based on predeter- Silence;Drill;System Reset;Lamp Test. mined levels of alarm. Pre-alarm operation can be latching or LCD Display: 80 characters(2 x 4.0)with long-life LED back- self-restoring,and can be used to activate special control func- light. tions. Self-Optimizing Pre-Alarm: Each detector may be set for Ordering Information "Self-Optimizing"pre-alarm. In this special mode,the detector "learns" its normal environment, measuring the peak analog • "Configuration Guidelines"on page 3 readings over a long period of time, and setting the pre-alarm • "Networking Options"on page 4 level just above these normal peaks. • "Auxiliary Power Supplies and Batteries"on page 4 Cooperating Multi-Detector Sensing: A patented feature of • "Audio Options"on page 4 ONYX intelligent sensing is the ability of a smoke sensor to . "Compatible Devices, EIA-232 Ports"on page 4 consider readings from nearby sensors in making alarm or "Compatible Devices, EIA 485 Ports"on page 4 pre-alarm decisions.Without statistical sacrifice in the ability to resist false alarms,it allows a sensor to increase its sensitivity • "Compatible Intelligent Devices"on page 4 to actual smoke by a factor of almost two to one. • "Enclosures,Chassis,and Dress Plates"on page 5 Field Programming Options • "Other Options"on page 5 CONFIGURATION GUIDELINES Autoprogram. This timesaving feature is a special software routine. The FACP "learns" what devices are physically con- The NFS-320 system ships assembled,*description and some nected and automatically loads them in the program with options follow. See "Enclosures, Chassis, and Dress Plates" default values for all parameters.Requiring less than one min- on page 5 for information about mounting peripherals. ute to run,this routine allows the user to have almost immedi- NOTE.Stand-alone and network systems require a main display. ate fire protection in a new installation,even if only a portion of On stand-alone systems,the panels keypad provides the required the detectors are installed. display. On network systems (two or more networked fire panel Keypad Program Edit(with KDM-R2)The NFS-320, like all nodes), at least one NCA-2, NCS, or ONYXWorks annunciation device is required. NOTIFIER intelligent panels, has the exclusive feature of pro- DN-7112:F2.9/7/2011—Page 3 of 6 Page 3 Page 4 NFS-320: The standard, factory-assembled NFS-320 system NFV 25/50ZST: 25 watt, 25 Vrms, emergency Voice Evacua- includes the following components:one control panel mounted tion Control Panel (VECP) with integral commercial micro- on chassis (120 V operation - ships with grounding cable, phone, digital message generator,zone splitter module(ACC- battery interconnect cables, and document kit); includes inte- ZSM),zone page module with keypad(ACC-ZPMK). See DN- gral power supply mounted to the main circuit board; one pri 60337. mary display KDM-R2 keypad/display; and one cabinet for surface or semi-flush mounting. Purchase batteries separately. COMPATIBLE DEVICES,EIA 232 PORTS One or two option boards may be mounted inside the NFS-320 PRN-6:80-column printer. See DN-6956. cabinet,•additional option boards can be used in remote cabi- VS4095/5:Printer,40-column,24 V.Mounted in external back- nets. box.See ON-3260. NFS-320R:Same as NFS-320 above,but in red enclosure. DPI-232: Direct Panel Interface, specialized modem for NFS-320C: Based on NFS-320 above. NFS-320C supports extending serial data links to remotely located FACPs and/or installation of an optional ACM-series annunciator in the same peripherals;mount on NFS-320 chassis. See DN-6870. cabinet.UL-and ULC-listed. NOTE.For additional information on NFS-320C,see DN-60085. COMPATIBLE DEVICES,EIA-485 PORTS ACM-24AT: ONYX Series ACS annunciator-up to 96 points NFS-320E: Same as NFS-320 above, but with 240 V opera- of annunciation with Alarm or Active LED, Trouble LED, and tion. switch per circuit. Active/Alarm LEDs can be programmed(by TR-320:Trim ring for the NFS-320 cabinet. powered-up switch selection)by point to be red,green,or yel- low;the Trouble LED is always yellow. See DN-6862. NETWORKING OPTIONS AEM-24AT: Same LED and switch capabilities as ACM-24AT, NCM-W, NCM-F: Standard Network Communications Mod- expands the ACM-24AT to 48,72,or 96 points.See DN-6862. ules. Wire and multi-mode fiber versions available. See DN- 6861. ACM-48A:ONYX Series ACS annunciator-up to 96 points of annunciation with Alarm or Active LED per circuit. Active/ HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed network Alarm LEDs can be programmed(by powered-up switch selec- communications modules.Wire,single-mode fiber,multi-mode tion)in groups of 24 to be red,green,or yellow.Expandable to fiber, and media conversion models are available. See DN- 96 points with one AEM-48A. See DN-6862. 60454. AEM-48A: Same LED capabilities as ACM-48A, expands the RPT W, RPT F, RPT WF: Standard-network repeater board ACM-48A to 96 points. See DN-6862. with wire connection (RPTW), fiber connection (RPTF), or allowing a change in media type between wire and fiber(RPT- ACM-8R: Remote Relay Module with eight Form-C contacts. WF).Not used with high-speed networks. See DN-6971. Can be located up to 6,000 ft. (1828.8 m)from panel on four wires. See DN-3558. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part num- LCD-80: ACS mode. 80-character, backlit LCD display. bers. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per NFN-GW-EM-3: NFN Gateway,embedded. FACP. See LCD-801-80TM(ON-3198). FDU-80: Terminal mode. 80-character, backlit LCD display. AUXILIARY POWER SUPPLIES AND BATTERIES Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per ACPS-610:6.0 A or 10 A addressable charging power supply. FACP. See DN-6820. See DN-60244. LC132-80: Terminal mode. 80-character, backlit LCD display. APS2-6R:Auxiliary Power Supply.Provides up to 6.0 amperes Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per of power for peripheral devices. Includes battery input and FACP. See DN-60548. transfer relay, and overcurrent protection. Mounts on two of LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM- four positions on a CHS-4L or CHS-4 chassis.See DN-5952. R32; remote custom driver modules. See DN-0551.. FCPS-24S6/S8: Remote 6 A and 8 A power supplies with bat- SCS:Smoke control stations SCS-8,SCE-8,with lamp drivers tery charger.See DN-6927. SCS-8L, SCE-8L; eight (expandable to 16) circuits. See DN- BAT Series: Batteries. NFS-320 uses two 12 volt, 18 to 200 4818. AH batteries.Mounts in NFS-LBB(R). See DN-6933. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit; mount on NFS-320 chas- sis or remotely. See DN-6860. NFV 25/50: 25 watt, 25 VRMS, emergency Voice Evacuation UDACT: Universal Digital Alarm Communicator Transmitter, Control Panel (VECP) with integral commercial microphone, 636 channel. See DN-486Z digital message generator,and single-/dualchannel Class A or Class B speaker circuits.See DN-7004. UZC-256: Programmable Universal Zone Coder provides pos- NFV 25/50DA:Single channel,25 Watt,25 VRMS,emergency itive non-interfering successive zone coding. Microprocessor- voice evacuation panel. See DN-60048. controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). Mounts in BB-UZC. See NFV 25/50DAZS: Single channel, 25 Watt, 25 Vrms, emer- DN-3404. gency voice evacuation panel. Can be automatically activated via the Zone System serial communication link from the NFV- COMPATIBLE INTELLIGENT DEVICES 25/50ZS. See DN-60049. BEAMHK: Heating kit for transmitter/receiver unit of NFV 25/50ZS:25 watt,25 Vrms,emergency Voice Evacuation FSB-200(S)below. See DN-6985. Control Panel (VECP) with integral commercial microphone, BEAMHRK: Heating kit for use with the reflector of digital message generator, zone splitter module (ACC-ZSM), FSB-200(S)below. See DN-6985. zone page module with keypad(ACC-ZPMK). See DN-7003 BEAMLRK: Long-range accessory kit, FSB-200(S) below. See DN-6985. Page 4 of 6-DN-7112:F2.9/7/2011 Page 4 Page 5 BEAMMRK: Multi-mount kit, FSB-200(S) below. See DN- XP6-MA: FlashScan six-zone interface module; connects 6985. intelligent alarm system to two-wire conventional detection BEAMSMK: Surface-mount kit, FSB-200(S) below. See DN- zone.See DN-6925, 6985. XP6-R: FlashScan six-relay (Form-C) control module. See FSB-200:Intelligent beam smoke detector. See DN-6985. DN-6926. FSB-20OS: Intelligent beam smoke detector with integral sen- XP10-M: FlashScan ten-input monitor module. See DN-6923. sitivity test.See DN-6985 ENCLOSURES,CHASSIS,AND DRESS PLATES FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria BB-UZC: Backbox for housing the UZC-256. Required for Detector. See DN-60412. NFS-320 applications.Black. For red,order BB-UZC-R. FSI-851: Low-profile FlashScan ionization detector. See DN- NFS-LBB: Battery Box (required for batteries larger than 26 6934. AH). FSP-851: Low-profile FlashScan photoelectric detector. See NFS-LBBR:Same as above,but red. DN-6935. SEISKIT 320IB26:Seismic mounting kit.Required for seismic- FSP-851T: Low-profile FlashScan photoelectric detector with certified applications with NFS-320 and BB-26. Includes bat- 135°F(57°C)thermal. See DN-6935. tery bracket for two 26 AH batteries. FSP-851 R:Remote-test capable photoelectric detector for use SEISKIT BB25: Seismic mounting kit for the BB-25. Includes with DNR(W)duct detector housings. See DN-6935. battery bracket for two 26 AH batteries. FST 851: FlashScan thermal detector 1350F (57°C). See SEISKIT LBB: Seismic kit for the NFS-LBB. Includes battery DN-6936. bracket for two 55 AH batteries. FST-851 R: FlashScan thermal detector 135°F (57°C) with SEISKIT PS/2/4: Seismic mounting kit for the FCPS-24S6/S8 rate-of-rise. See DN-6936. and CAB-PS1. Includes battery bracket for two 7 AH or 12 AH FST851H: FlashScan 190°F(88°C)high-temperature thermal batteries. detector. See DN-6936. OTHER OPTIONS FAPT851: FlashScan Acclimate Plus low-profile multi-sensor 411:Slave Digital Alarm Communicator.See DN-6619. detector. See DN-6937. FSL-751: FlashScan VIEW laser photo detector. See DN- 411 UDAC:Digital Alarm Communicator. See DN-6746. 6886. IPDACT2/2UD, IPDACT Internet Monitoring Module: Con- DNR: InnovairFlex low-flow non-relay duct-detector housing nects to primary and secondary DACT telephone output ports (order FSP-851 R separately). Replaces FSD-751 PUFSD- for internet communications over customer-provided ethernet 751 RPL. See DN-60429. connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static IP. See DN-60408. DNRW: Same as above with NEMA-4 rating, watertight. See IPSPLT:Y adaptor option allow connection of both panel dialer DN-60429. outputs to one IPDACT-2/2UD cable input. B224RB:Low-profile relay base.See DN-60054. IPENC: External enclosure for IPDACT, includes IPBRKT B224B1: Isolator base for low-profile detectors. See DN- mounting bracket; Red.For Black order IPENC-B. 60054. IPGSM-COM: Internet and Digital Cellular Fire Communicator B21OLP: Low-profile base. Standard U.S. style. Replaces Panel. Uses internet as primary with dual GSM technology as B710LP. See DN-60054. backup. Connects to the primary and secondary ports of a B501: European-style,4°(10.16 cm)base.See DN-60054. DACT.See DN-60656. B20OS: Intelligent addressable sounder base,capable of pro- VeriFire-TCD: VeriFire Tools CD-ROM. Contains program- ducing a variety of tone patterns including ANSI Temporal 3. ming software for the ONYX Series. Includes local panel con- Compatible with sychronization protocol.See DN-60054. nection cable.See DN-6871. B200SR: Sounder base, Temporal 3 or Continuous tone. See VeriFireUG-TCD:VeriFire Tools upgrade software. DN-60054. NFS-320-RB: Replacement CPU. NOTE: Keypad must be FMM-1: FlashScan monitor module.See DN-6720. removed before shipping old unit out for repair. FDM-1: FlashScan dual monitor module.See DN-6720. • NFS-320-RBE: Replacement CPU, Export. FZM-1:FlashScan two-wire detector monitor module.See DN- • NFS-320-RBC-FR:Replacement CPU,Canadian French. 6720. • NFS-320-RB-PO: Replacement CPU,Portuguese. FMM-101: FlashScan miniature monitor module. See DN- • NFS-320-RB-POE: Replacement CPU, Export, Portu- 6720. guese. FCM-1: FlashScan NAC control module. See DN-6724. • NFS-320-RB-SP: Replacement CPU,Spanish. • NFS-320-RB-SPE:Replacement CPU,Export,Spanish. FCM-I-REL: FlashScan releasing control module. See DN- NOTE.For other options including compatibility with retrofit equip- 60390. ment,refer to the panels installation manual,the SLC manual,and FRM-1:FlashScan relay module. See DN-6724. the Device Compatibility Document. NBG-12LX:Manual pull station,addressable. See DN-6726. ISO-X: Isolator module.See DN-2243. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. DN-7112:F2.9l7/2011-Page 5 of 6 Page 5 1 Page 6 SYSTEM SPECIFICATIONS System Capacity components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that • ,Intelligent Signaling Line Circuits ......................................1 this system and its peripherals be installed in an environment • Intelligent detectors .......................................................159 with a normal room temperature of 15—270C/60—80°F. • Addressable monitor/control modules............................159 • Programmable internal hardware and output circuits ........4 Agency Listings and Approvals • Programmable software zones.........................................99 The listings and approvals below apply to the basic NFS-320 • Special programming zones.............................................14 control panel. In some cases, certain modules may not be • LCD annunciators per NFS-320/-320E """""""""""""'32 listed by certain approval agencies, or listing may be in pro- • ACS annunciators cess.Consult factory for latest listing status. per NFS-320/-320E .....................32 addresses x 64 points . UL Listed:S635 • ULC Listed:S635(NFS-320C only,excludes IPDACT) Specifications • FM Approved • Primary input power • CSFM:7165-0028:0243 —NFS-320: 120 VAC,50/60 Hz,5.0 A. • MEA: 128-07-E —NFS-320E:220/240 VAC,50/60 Hz,2.5 A. • FDNY:COA#6067,6085 • Total output 24 V power:6.0 A in alarm. • City of Chicago NOTE: The power supply has a total of 6.0 A of available power. NOTE. For additional information on UL- and ULC-listed model This is shared by all internal circuits. NFS-320C,see DN-60085. For information on NFS-320SYS, see DN-60637. • Standard notification circuits(4): 1.5 A each. • Resettable regulated 24V power: 1.25 A. Standards • Two non-resettable regulated 24V power outputs: The NFS-320 complies with the following UL Standards and —1.25 A. NFPA 72, IBC,and CBC Fire Alarm Systems requirements: —0.50 A. • UL 864(Fire). • Non-resettable 5V power:0.15 A. . UL 1076(Burglary). • Battery charger range:18 AH—200 AH.Use separate cabi- . LOCAL (Automatic, Manual, Waterflow and Sprinkler net for batteries over 26 AH. Supervisory). • Float rate:27.6 V. • AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). Cabinet Specifications • REMOTE STATION (Automatic, Manual, Waterflow and NFS-320 cabinet dimensions: Sprinkler Supervisory)(requires TM-4). • Backbox:18.12 in.(46.025 cm)width; 18.12 in.(46.025 cm) . PROPRIETARY (Automatic, Manual, Waterflow and Sprin- height;5.81 in.(14.76 cm)depth. kler Supervisory).Not applicable for FM. • Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) . CENTRAL STATION (Automatic, Manual, Waterflow and height;0.75 in.(1.905 cm)depth. Sprinkler Supervisory)(requires UDACT). • Trim ring:Molding width is 0.905 in.(2.299 cm). • EMERGENCY VOICE/ALARM. • Shipping weight(without batteries):36.15 lb.(16.4 kg). • OT,PSDN(Other Technologies, Packet-switched Data Net- work). Temperature and Humidity Ranges • IBC 2000,IBC 2003,IBC 2006,IBC2009(Seismic). This system meets NFPA requirements for operation at 0 — • CBC 2007(Seismic). 49°C/32 — 120°F and at a relative humidity 93% t 2% RH (noncondensing) at 32°C t 2°C (90oF t 30F). However, the useful life of the system's standby batteries and the electronic NOTI•FIRE•NETTM,IntelllOuad'"',and ONYXWorksT are trademarks;and Acclimate®PIusTM, FlashScan®, NOTIFIER®, ONYX®, VerlFlre®, and VIEW®are registered trademarks of Honeywell International Inc.Microsoft® and Windows®are registered trademarks of Microsoft Corporation.IBM®is a registered trademark of IBM Corporation. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. BIilNE9INC&AIANIFACTiRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6—DN-7112:1`2.9/7/2011 Page 6 Page 7 Honeywell IPGSM-4G Single or Dual Path Commercial Fire Communicator General •-� The IPGSM-4G is a commercial fire alarm communicator that i offers contact ID reporting with any Fire Alarm Control Panel (FACP)that has a built-in dialer.This single or dual path com- municator connects directly to the primary and secondary communication ports of a fire panel's Digital Alarm Communi- cator Transmitter (DACT). It offers three selectable reporting paths which include:Cellular only, IP only,or IP primary/cellu- lar backup. All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet Network Control Center, which routes highly encrypted Ethernet data packets via a customer pro- vided internet connection or cellular network to the appropriate central station. The state of the art AlarmNet network control center is fully redundant and monitored 24/7. AlarmNet has . Operates over the following communication protocols: the ability to route messages using AlarmNet-I and 800 PLUS HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) services, providing true redundancy and multipath message GPRS(2G). delivery. Selectable reporting paths and supervision intervals to Alternative communication methods are critical in the market- meet NFPA 72, chapter 26 requirements. (Compliant with place due to VoIP(Voice over IP),migration from POTS(Plain NFPA 72 2010 and 2013 supervision requirements.) Old Telephone Service) and growth of digital radio networks. . Works over any type of customer provided Ethernet 101100 The IPGSM-4G's single path communications solution allows based network connection (LAN or WAN), DSL modem or one technology to be used(either IP or cellular)to provide the cable modem. appropriate connectivity to a central station.For added reliabil- ity, our exclusive dual path solution allows both technologies • Data transmits over standard contact-ID protocol but is (IP and cellular)to be used together for maximum survivability secured with the industry's advanced encryption standard or for local jurisdiction requirements that specify a dual tech- (AES 256 bit). nology system. • Supports both dynamic(DHCP)or Public and Private Static The IPGSM-4G is designed to operate over the most common IP addressing. cellular platforms, including 2G, 3G, and HSPA+. Its multi- . Built-In Power Supply module: On board charging circuit GSM platform technology automatically chooses the best design accommodates back-up battery. Includes primary available cellular signal in the area based on signal strength power and battery supervision. and seamlessly self-adjusts to maintain critical life safety com- • Diagnostic LEDs:Signal strength and status indicators. munication. In addition, it connects to any type of customer . Reliable connection: IP and GSM connection tested every provided Ethernet 10/100 base network connection (LAN or day. WAN), DSL model or cable modem. Our selectable reporting QOS:Quality of Service diagnostics via AlarmNet conveys path feature allows the radio to be configured for a single or dual path solution as well as the appropriate supervision inter- vital communicator information including when message vals based on NFPA 72 requirements. (See diagram below for was received,signal strength,and message path used. selectable paths and supervision timing intervals.) • 7720P Hand-held programmer for easy setup. Operation Selectable Path Description Supervision When an event occurs,the Fire Alarm Control Panel goes off Times hook to dial the central station.The IPGSM-4G Dialer Capture 2010 GSM Single Path(cellular only) 5 minutes Module detects the off-hook condition and provides the fire panel with a dial tone. When the fire panel detects the dial 2010 IP Single Path(IP only) 5 minutes tone, it begins dialing the central station. After the dialing is 2010 IP&GSM Dual Path(IP and cellular) 24 hours completed,the Dialer Capture Module returns a handshake to 2013 GSM Single Path(cellular only) 1 hour the fire panel.The fire panel then sends the contact ID reports to the Dialer Capture Module, which in turn sends a kiss-off 2013 IP Single Path(IP only) 1 hour after the report is successfully received from the fire panel. 2013 IP&GSM Dual Path(IP and cellular) 6 hours The Dialer Capture Module sends the contact ID reports to the IPGSM communications module. When all the reports are sent, the fire panel goes on-hook. The IPGSM communica- Features tions module then transmits the messages to the central sta- • Saves the cost of two dedicated phone lines. tion either over the GSM network or the Internet (dependent • Single or dual path communications. (Can communicate to on configuration). central station using cellular technology,internet or both. Easy to Program • Requires no change to the existing Fire Alarm Control Panel configuration. (Connects directly to the primary and The IPGSM-4G communicator can be pre-programmed using secondary telephone ports of a DACT.) the 7720P programmer to enter all central-station information. Thi is saved to the IPGSM 4G communicator panel memory. Page � Page 8 When the IPGSM-4G communicator is installed at the site and —One 12 V 7.0 AH lead-acid battery(not supplied). connected to the Internettintranet, it registers itself with the —Battery charging current:1 Amp maximum. AlarmNet receiver. —Battery discharge current: Standby 230mA, Active .For most installations,the only required parameters are: 950mA. • Primary City ID (two digits) obtained from your monitoring station. Cabinet Specifications • Primary Central Station ID (two digits) obtained from your Dimensions- 14.875"H x 12.75"W x 3.0"D(37.8 cm H x 32.4 monitoring station. cm W x 7.6 cm.D). • Primary Subscriber ID(four digits)obtained from your mon- Color:Red. itoring station. • Communication Module's MAC ID, and MAC CRC number Shipping Specifications located on outside of box,and inside of the module. All of these parameters are assigned by the monitoring station. Weight: lbs. .6.94 kg). Dimensions: 15.625" H x 13.79" W x 9.25" D (39.7 cm H x NOTE: Some assembly is required. See Installation and Setup 34.9 cm W x 23.9 cm D) Guide#800-12454 for full details. Fire Communicator Capability Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - The IPGSM-4G is compatible with fire panels that use the 49°C/32-120°F and at a relative humidity 93%±2%RH(non Contact ID communications format as described in the SIA condensing at 320C±20C (90oF±3'F). However,the useful DC-05 standard. life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature AlarmNet ranges and humidity. Therefore, it is recommended that this Honeywell's AlarmNet has been the nationwide leader in system and its peripherals be installed in an environment with alarm communications technology since 1986.A reliable alter- a normal room temperature of 15-27"C/60-80°F. native for the transmission of alarm signals,our radio network provides extensive coverage in the United States and Canada. Product Line Information AlarmNet Network Control center processes signals from pow- IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- erful servers in multiple locations equipped with 24N infra- cator Panel. Includes red cabinet with Ademco key and lock, structure support.The AlarmNet network consist of redundant wall outlet box,Dialer Capture Module,IGSM Communications hardware servers,hot back-up databases and generators with Module, antenna & mounting adapter, PowerBoostl power battery back-up at all locations to ensure continuity of service. supply, LED display board, transformer, manual, & required Signals from Alarm-Net are transmitted to the central station's screws,cables,etc. receivers using multiple communications paths consisting of Antenna External Hardware the Internet,radio network or toll-free POTS service. GSM-ANT3DB:3db gain external/remote antenna. Installation Requirements WA7626-CA:SNA to N Adapter. 7626-50HC:50 ft.antenna cable,low loss. UL COMPLIANCE 7626-25HC:25 ft.antenna cable,low loss. To meet UL864/NFPA,ensure the following: NOTE: The GSM ANT3DB and the WA7626-CA are both required • IPGSM-4G must be installed in accordance with NFPA for installing an external antenna along with the necessary cable (National Fire Protection Association)standards 70 and 72. needed(7626-5014C:50 ft.or 7626-25HC:25 ft.) • IPGSM-4G must be mounted in the same room and within Other Accessories 20 feet of the fire panel. 7720P:IPGSM-4G hand held programmer. • IPGSM-4G, and all equipment used for the IP connection HPTCOVER:Plug in transformer box for IPGSM communicator. (such as the router,hub, modem,etc.)shall be listed, must BAT-1 270: Battery 12 Volts,7 AH,sealed. be powered from an un-switched branch circuit,and be pro- vided with appropriate standby power. Agency Listings and Approvals • IPGSM-4G must use the 7AH battery(not supplied)to pro- The listings and approvals below apply to the basic IPGSM-4G vide 24-hour backup capability. communicator panel.In some cases,certain modules may not be Electrical Specifications listed by certain approval agencies,or listing may be in process. Consult factory for latest listing status. Transformer: UL Listed:S789. —Primary 120VAC,60Hz,0.5A. CSFM:7300-1645:0199. —Secondary:18VDC,50VA. FDNY:COA#6219. Battery: Page 2 of 3—DH-60769:E•9/16/16 www.honeywell.com Page 8 Page 9 This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot coverall specific applications or anticipate all requirements.All specifications are subject to change without notice. ©2017 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877)HPP-POWR Northford,CT 06472-1610 hpp_techserv@honeywell.com www.honeyweilpower.com DH-60769:E - June 2017 Made InRegistered U.S.A. IS® ®U.S.Registered Trademark ©2017 Honeywell Internatio 151 c. Page 3of3 age,, SYSTEMS Page 10 DN-60686:A1 UDACT-2 N OT I F I E R° Universal Digital Alarm (a Communicator Transmitter by H o n eywe I I Annunciator Control System ' General �, F The Universal Digital Alarm Communicator Transmitter(UDACT- 2)is designed for use on Notifier Fire Alarm Control Panels and on the NCA-2 Network Control Annunciator.When used in con- junction with the NCA-2 network control annunciator, the UDACT-2 can report the status of all control panels on NOTI•FIRE•NETTM.The UDACT-2 transmits system status to UL �! listed Central Station Receivers via the public switched tele- phone network.The UDACT-2 can be installed in the panel cab- $ inet or remotely in a separate enclosure. y = NOTE. The UDACT-2 can also be used with legacy panels. Please refer to the UDACT-2 manual for more information. The UDACT-2 upload/download programming and firmware updates are accomplished with VeriFire Tools. Refer to the Pro- gramming Section for further details. • The UDACT-2 is capable of transmitting the status of software zones(Alarm and Trouble), System Trouble, Panel Off-Normal, _ Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT-2 is capable of transmitting all of the zone and point sta- tus associated with each panel. _ When the UDACT-2 is used with the NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Report- ing may be in the form of points or zones(refer to the UDACT-2 manual for specific reporting parameters). Points transmitted may be programmed for a variety of types, including fire,water- flow,supervisory,etc. UDACT-2 NOTE.Descriptions regarding point capacity,listed above,are for receivers which receive in Ademco Contact ID format. See chart • Open Collector relay driver for Total Communications Failure on page 2 for compatible receivers. or UDACT-2 trouble. Features • Real-time clock. • Extensive transient protection. • Programmable with VeriFire Tools version 6.60 or higher, . EIA-485 interface to host panel. allowing the UDACT-2 programming to be uploaded/down- loaded and saved. Programming • Maximum of 14 point trouble messages transmitted per hour. The UDACT-2 programming is created and downloaded using • Dual phone lines with line voltage detect. VeriFire Tools.This enables the unit to be programmed prior to • Compact in size:6.75"x 4.25"(17.145 x 10.795 cm). installation, be easily modified, and saved either online or • USB port for upload/download programming. offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- • Manual Test Report function. work annunciator.The point report consists of the central station • Manual Transmission Clear function. point address,ACS point,ACS point function,panel label,panel • Mounts in a separate enclosure(ABS-8RB or UBS-1 B/R). point,type code,custom and extended label,alarm verification, • Communicates vital system status including: walktest participation,presignal,and PAS information.The zone —Independent zone fire alarm. report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label —Independent zone non-fire alarm. and panel label.This report may be sent to the Central Station —Independent zone trouble. for their records. VeriFire Tools also supports upgrading the —Independent zone supervisory. UDACT-2 operating firmware. —AC(mains)Power Loss(programmable). —Low Battery and Earth Fault. —System Off-Normal. —12 or 24 hour test signal. —Abnormal Test Signal per new UL requirements. —EIA-485 Communication Bus Failure. • Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. • Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- soff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. DN-60686:A1•4/2/12—Page 1 of 2 Page 10 Page 11 Communication Formats UL Listed Receivers • Ademco Contact ID The chart below shows UL listed receivers compatible with the • 4+2 Standard UDACT-2. A check in the protocol column indicates the receiver • SIA supports that protocol. NOTE:Ademco Contact ID must be used for independent zone reporting. 4+2 Ademco Type Mode Feature Standard Contact Ademco Contact ID format - only Use Type Mode to identify Receiver 1800/2300 ID SIA reports to Central Station as: Ademco 685(1) • Fire Alarm •Burglary • Supervisory •24 hour Non-Burglary Ademco MX8000(2) • Pull Station •High Temperature Silent Knight 9500(3) • Heat Detector •Low Temperature • Waterflow •Low Water Pressure Silent Knight 9800(4) • Duct Detector •Low Water Level • Flame Sensor •Pump Failure FBI CP220FB(5) • Smoke Zone Osborne Hoffman 2000E(6) Electrical Specifications Radionics 6600(7) Standby current:40 mA. SurGard MLR2(8) Current while communicating:75 mA. Maximum current while communicating and with open collector SurGard System III(9) output activated:100 mA. SurGard MLR-2000(10) Voltage: Regulated 24 volts.Range:21.2 to 28.2 volts. Agency Listings and Approvals (1)With 685-8 Line Card with Rev 4.4d software (2)With 12406OV206B and 124063 Line Card Rev B a some cases, certain modules may not be listed by certain (3)With version V2.4 Receiver&126047 Line Card Rev G approval agencies,or listing may be in process. Consult factory for latest listing status. (4)With 124077V2.00 Receiver&126047 Line Card Rev M • UUULC Listed:S635 (5)With software V3.9 • FM Approved (6)With V.7301 Receiver S/W • CSFM: 7165-0028:0243 (NFS2-640/320), 7165-0028:0224 (7)With 01.01.03 Receiver S/W&Line Card 01.01.03 (NFS2-3030) (8)With software V1.86 • FDNY:COA#6085,COA#6098 (9)With sotware V1.72 Ordering Information (10)With DSP4016 and V1.6 Line Card UDACT2: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions,and mounting hardware. MCBL-7: DACT phone cord,7 ft(2.13 m)long(two required). ABS-8RB:Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP.9.94"H x 4.63"W x 2.50" D(cm:25.248 H x 11.760 W x 6.350 D). UBS-1 B:Metal enclosure with solid door, Black. UBS-1BR:Metal enclosure with solid door, Red. R-10E:SPDT Form-C relay.Contacts rated for 10 A @ 115 VAC. Connects to open collector relay driver. R-20E:DPDT Two Form-C relays.Contacts rated for 10A @ 115 VAC.Connects to open collector relay driver. NOTI•FIRE•NETTM'is a trademark and Notifier®is a registered trademark of FB13-1:Ferrite bead kit. Use for remote mounting only. Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. BY61NUiIIIIA 8 MANOMMENB All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60686:A1•4/2/12 Page 11 Page 12 DN-6862:C1•D-95 ACS Series Annunciators � N OT I F I E R® ONYX Series ACM/AEM;24AT ACM/AEM-48A by Honeywell Annunciator . General 0 0 The ONYX®Series ACS'Annunciators provide a modular line of products for annunciation and control of the NOTIFIER ONYX®Series Intelligent Fire Alarm Control Panels, Network _ 00, fJ�i 00 l0>•1 Control Annunciators, and NOTIFIER's legacy addressable ; ■ ; ■ o panels.The ACS line provides arrays of LEDs to indicate point : ■ : ■ status and, in some versions, switches to control the state of : ■ : ■ output circuits.These ACS units use a serial interface and may 10 be located at distances of up to 6,000 feet (1,828.8 meters) from the panel. : ■ ( : ■ �. Features ■ J■ ° �=Jm : ■ —i • Speaker control mode for use with XPIQ and the following : ■ i : ■ panels: NFS2-3030, NFS2-640, NFS-320(C) and NFS- 320SYS. Enables the ACS to control operation of groups of • ■ ■ o multi-channels mapped to groups of multi-speakers. ■ ■ �o • Compatible with existing annunciators. • ■ • Color-programmable LEDs. ACM/AEM-24AT _ ACM/AEM-48A • On-board end-of-line resistors can be enabled/disabled by setting a switch. o 0 6862aY24.wmf 6862a48.wmf • Alarm/Circuit On and Trouble LED per-point thxoption or more dense Alarm-only option. Touch-pad control switch option for remote control of sys- standby batteries and the electronic components may be • tem relays;or silence, reset,and evacuate. adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and all • LEDs may be programmed to display status of indicating peripherals be installed in an environment with a nominal room circuits or control relays as well as system status condi- temperature of 150C to 270C(60°F to 800F). tions. • System Trouble LED indicator. Installation • On-Line/Power LED indicator. The ACS Series annunciator and control subsystems use • Alarm and trouble resound with flash of new conditions. modular hardware assemblies which allow the custom configu- • Local sounder for both alarm and trouble conditions with ration of the annunciator panel to fit the individual job require- silence/acknowledge button(program options). ments. • May be powered by 24 VDC from the panel or by remote Standard backboxes and mounting hardware schemes,includ- power supplies. ing special remote cabinets,allow the annunciators to be con- • Microprocessor-controlled electronics,fully supervised. structed and configured with other system components. • Slip-in custom labels, lettered with standard typewriter or When used with the NFS2-3030, NFS2-640, NFS-320 or leg- LabelEase program. acy panels,the ACS modules can be used for manual selec- • Plug-in terminal blocks for ease of installation and service. tion of speaker and telephone circuits. In this application,they are typically mounted in the main control near the microphone Construction and telephone handset. For remote annunciation applications, the modules are typi- The ACS modules are provided in two basic controller mod- cally mounted in special ABF or ABS boxes.Control switch key ules,each with its expander module.The ACM-24AT provides locks(AKS-1 B)are available. 24 annunciation and control points per module, each with a red, green, or yellow Alarm/Circuit On LED, a yellow Trouble Communication between the ACS Series annunciators and the LED, and a touch-key switch. The ACM-48A provides 48 host Fire Alarm Control Panel is made through an EIA-485 annunciation points per module,each with a red,green,or yel- multi-drop loop, eliminating the need for costly wiring low Alarm/Circuit On LED(for annunciating control relays,the schemes. Four wires are required, two for the EIA-485 com- LED indicates ON/OFF). munications (twisted pair), and two for 24 VDC .regulated On the ACM-24AT, each LED point is Individually color-pro- power. grammable.On ACM-48A,each column of 24 LED points can Retrofit of ACS Series annunciators into existing systems is be color-configured using a DIP switch. easily accomplished. Software may require upgrading, and Temperature and humidity ranges: This system meets some legacy panels may require an interface board. NFPA requirements for operation at 0°C to 49°C (32°F to All field-wiring terminations use removable, compression-type 1200F); and at a relative humidity(noncondensing)of 85%at terminal blocks for ease of installation,wiring,and circuit test- 30°C(86°F)per NFPA,and 93%t 2%at 32°C t 2°C(89:6°F it ing. 1.1°F) per ULC. However, the useful life of the system's DN-6862:C1•8/112011—Page 1 of 4 Page 12 Page 13 Operation in frontal appearance to the ACM-48A.One expander module The ACS Series annunciator and control system provides the can be supported by an ACM-48A,providing a maximum of 96 1.27 NOTIFIER system with up to 32 remote serially connected points (subject to the capability of the . The EM-4 can annunciators, each with a capacity of 96 points, for a total cm) high;4.375°(11.11 cm)wide. NOTE: The AEM-48A can- not be used to expand the ACM-24AT. capacity of 3072 points(subject to the capability of the FACP). ABS-1 B: (see figure)The Annunciator Surface Box-1 B black The NFS2-3030 and NCA-2 are capable of using the full 96 (black) points. provides for the remote mounting of one annunciator module in a surface-mount enclosure. Knockouts are provided for use Local or remote power supplies and serial communications with 1/2"(1.27 cm)conduit.The annunciator mounts directly to allow the ACS to be located virtually anywhere in the protected the ABS-1 B without a dress plate. 8.5"(21.59 cm) high x 4.5" premises. (11.43 cm)wide x 2"(5.08 cm)deep. NOTE:The ABS-1B will On NFS-320, NFS2-640, NFS2-3030, NCA-2 and the legacy not support the installation of the AKS-1B Annunciator Key panels,system alarm and/or trouble conditions may be annun- Switch. ciated on a per-point basis,or in a grouped or zone configura- tion. ABF-1 B 50439d2.8f Control of system operational controls,such as Signal Silence, System Reset,and local annunciation controls(such as Local rn e Acknowledge and Lamp Test) may be accomplished through o 9 the module's rubber keypad. 0 Product Line Information ACM-24AT: (see figure) The Annunciator Control Mod- ule-24AT contains 24 color-programmable (red/green/yellow) O Active and 24 yellow Trouble LEDs, 24 momentary touch-pad switches,a System Trouble LED, an On-Line/Power LED, and m a local piezo sounder with a silence/acknowledge switch for audible indication of alarm and trouble conditions. Includes 0 instructions.8.375"(21.27 cm)high;4.375"(11.11 cm)wide. m o 50439d3.tif ®m O O ABS-1 B ABS-1TB:The ABS-1TB is an attractive surface-mount back- box for mounting one ACS Series Annunciator. Unlike the L loo o moo �O ABS-iB, the ABS-1TB has an increased depth that allows • • mounting of the AKS-1 B Annunciator Key Switch. Black, : ■ : ■ , 9.938" (25.24 cm) high x 4.625" (11.75 cm)wide x 2.5" (6.35 ■ : ■ cm) deep. NOTE: An earlier gray model, ABS-1TB, will not 7­10 ; • accommodate the ACM/AEM-24AT or ACM/AEM-48A. The -: • : • slightly deeper ABS-1 TB will accommodate both the ACM/ -: • r : • AEM-24AT or ACM/AEM-48A models and the ACM-16ATI ACM-32A Series(see DN-0524). • • �� ■ � ; ABS-2B:The Annunciator Surface Box-2B(black)provides for ' • ' • , the surface mounting of one ACM-24AT/AEM-24AT combina- • • i tion or one ACM-48A/AEM 48A combination. Knockouts are • • provided for use with 1/2"(1.27 cm)conduit.The annunciators • Mod i mount directly to the ABS-2B without a dress plate.8.5"(21.59 ■ : ■ cm)high x 8.92"(22.66 cm)wide x 2"(5.08 cm)deep. NOTE: The ABS-2B will not support the installation of the AKS-1B ACM/AEM-24AT ACM/AEM-48A Annunciator Key Switch. 0 o ABF-1 B: (see figure)The Annunciator Flush Box-1 13 (black) 6862a124.-f 6862a48.wmf provides for the remote mounting of a single annunciator mod- ule in a flush-mount enclosure.Knockouts are provided for use AEM-24AT:The Annunciator Expander Module-24AT expands with 1/2" (1.27 cm) conduit. The ABF-1 B includes a painted the ACM-24AT by 24 system points.The AEM-24AT is identi- black metal trim plate 111"(27.94 cm)high x 6.25"(15.875 cm) cal in size and in frontal appearance to the ACM-24AT. Up to wide],mounting hardware,and an adhesive-backed annuncia- three of these expander modules can be supported by an for label for the dress plate. 9.938" (25.24 cm) high x 4.625" ACM-24AT,for a maximum of 96 system points. 8.375"(21.27 (11.75 cm)wide x 2.5"(6.35 cm)deep. cm)high;4.375"(11.11 cm)wide.NOTE:The AEM-24AT can- ABF-213: The Annunciator Flush Box-213 (black) provides for not be used to expand the ACM-48A. the flush mounting of two annunciator modules. Includes a ACM-48A: (see figure)The Annunciator Control Module-48A painted black metal trim plate [11" (27.94 cm) high x 10.625" contains 48 color-programmable (red/green/yellow) Active (26.99 cm) wide] and adhesive-backed annunciator label. LEDs, a System Trouble LED, an On-Line/Power LED, and a 9.938" (25.24 cm) high x 9.188" (23.34 cm) wide x 3.75" local piezo sounder with a Silence/Acknowledge switch for (9.525 cm)deep. audible indication of alarm and trouble conditions. Includes ABF-413: (see figure)The Annunciator Flush Box-4B (black) Instructions.8.375"(21.27 cm)high;4.375"(11.11 cm)wide. provides for the remote mounting of one to four annunciator AEM-48A: The Annunciator Expander Module-48A expands modules. Knockouts are provided for use with 1/2° (1.27 cm) the ACM-48A by 48 system points. The AEM-48A is identical conduit. The flush-mounted ABF-4B includes a painted black metal trim plate [11" (27.94 cm) high x 19.375" (49.21 cm) Page 2 of 4-DN-6862:C1•8/1/2011 Page 13 Page 14 wide] and an annunciator label. 9.938" (25.24 cm) high x 6858disp.w f 17.75"(45.09 cm)wide x 2.5°(6.35 cm)deep. ABF-4B O �� ® ° 's =o-0 ' O eoee oao o�aoe ® = 0 oaefae ol 9®=off ®. ®oeeoeGGeoo® -0--13 m O DP-DISP Dress Panel with NCA-2 Network Control o O Annunciator in left two positions,and two ACM-24AT Annunciators at right ® BMP-1: Annunciator Blank Module is a flat black dress plate that covers unused module positions in the annunciator back- a ® box or in the ADP-413.8.375" (21.27 cm)high x 4.375" (11.11 O cm)wide. Studs for a variety of module mounting options are a ° available. m AKS-1 B: The Annunciator Key Switch-1 B (black) provides 50439dt.tif 0 access security for the control switches on the ACM/ AEM-24AT.The key switch kit includes a key and hardware for mounting to the ABF-1 B.Also included is an adhesive-backed annunciator label for use with the key switch/dress .plate ABF-1 DB,ABF-2DB,ABS-413:The ABF-1 DB,ABF-2DB and assembly. NOTE:The AKS-1B can only be employed with the ABS-41) are semi-flush-mount backboxes for ACS Series ABS-1TB. Annunciators.The ABF-1 DB mounts one annunciator module; the four Am dues. The A S 4D Series can amounts two modules;the s o ac omodate themounts u to Agency Listings and Approvals NCA-2 network annunciator, using the NCA-2 Retro Kit(NCA- The listings and approvals below apply to the ACM/AEM-24AT 2Retro); the NCA-2 is mounted in the center position with a and the ACM/AEM-48A. In some cases, certain modules or blank plate (BMP-1) mounted on each side. Black with an applications may not be listed by certain approval agencies,or attracted smoked glass door and keylock. The ABS-413 is listing may be in process.Consult factory for latest listing sta- hinged on the bottom for stability. tus. • DIMENSIONS, ABF-iDB: Box only: 9.938" (25.24 cm) • UL:S635 high x 4.625"(11.75 cm)wide x 2.5"(6.35 cm)deep.Door: . ULC:S635 11" (27.94 cm) high x 6" (15.24 cm) wide x 0.75" (1.9 cm) . FDNY:COA#6067(NFS2-640),COA#6065(NFS2-3030) deep. CSFM: 7120-0028:0156, 7165-0028:0243, 7165- • DIMENSIONS, ABF-2DB: Box only: 9.938° (25.24 cm). 0028:0224 high x 9.188" (23.34 cm) wide x 3.75" (9.525 cm) deep. Door: 11" (27.94 cm) high x 10.375" (26.35 cm) wide x FM approved 0.75"(1.9 cm)deep. • DIMENSIONS,ABS-413: Box only:11.97°(30.40 cm)high x 19.87" (50.47cm) wide x 3.50" (8.89 cm) deep. Door: 11.97" (30.40 cm) high x 19.87" (50.47 cm) wide x 1.25" (3.18 cm)deep. ADP-4B:The Annunciator Dress Panel-46(black)provides for the cabinet mounting of one to four modules. The ADP-413 hinge-mounts to the CAB-4 Series cabinet. Modules mount directly to threaded studs on the dress panel. DP-DISP: (see figure)The Dress Panel-Display allows one to four modules to be mounted in the top row of the CAB-4 Series backbox. Modules mount directly to threaded studs on the DP-DISP. DP-DISP2: NFS2-640 Dress Panel accomodates up to two annunciator modules(no expanders). DN-6862:C1•8/1/2011-Page 3 of 4 Page 14 Page 15 ONYX@ and NOTIFIER@ are registered trademarks of Honeywell Interna- tional Inc. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. _ We cannot cover all specific applications or anticipate all requirements. MCINEMINC 6MMFUTINNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6862:C1•8/1/2011 Page 15 Page 16 September 29,1999 D-500 • Fi e-LITe®ALcgrmS PS Series Batteries Section: Power Supplies/Accessories GENERAL Power-Sonic PS Series batteries provide secondary power for the S whole series of Fire•Lite fire alarm control panels. FEATURES MH14328 (S) • Provide secondary power for control panels. • Gelled electrolyte. • Sealed and maintenance-free. • Overcharge protected. • Extended shelf life. • Easy handling with leakproof construction. • Ruggedly constructed, high-impact ABS plastic case. • Long service life. • Compact design. CAPACITY Battery capacity,expressed in ampere-hours(AH),is the product of a discharge current and the length of time that the current is dis- charged. Batteries are rated according to their performance during 20 hours of discharge at a constant current. The rated capacity of a battery is determined by subjecting it to a constant discharge current for 20 hours at 68*F (20°C). After 20 hours the voltage across the terminals is measured.The discharge current which causes a reading of 1.72 volts per cell(5.16 V on a 6 V battery and 10.32 V on a 12 V battery)is called the rated current. SEALED RECHARGEABLE This current multiplied by 20 is the rated capacity of the battery. BATTERY APPLICATIONS SON/C Use the PS Series batteries to provide backup power for control Model PS-695 B Volt 9.5 AH panels. Select batteries based on current requirements for your Power-Sonic Corporation system and the capacity of its charger. These batteries can be used over a temperature range of-76°F to+140°F(-60°C to+600C). CONSTRICTION The sealed construction of the Power-Sonic battery allows trouble- free,safe operation in any position. There is no need to add elec- trolyte,as gases generated during overcharge are recombined in a _ unique"Oxygen Cycle." The battery is sealed,leakproof,and main- tenance-free. The case is made of ABS,a high-impact plastic resin (acrylonitrile butadiene styrene copolymer)with high resistance to chemicals and flammability_ The PS-695 Battery INSTALLATION All panels have space reserved for batteries. See the appropriate panel installation manual for battery size restrictions. Typical inter- connection diagrams are shown in the literature accompanying each control panel. This document is not intended to be used for installation purposes.we try to keep our prod- ISO-9001 uct information up-to-dale and accurate.we cannot cover all specific applications er antici pate all requirements. All specifications are subject to change without notice. For more Engineering and Manufacturing information,contact Fire-Lite. Phone-,(203)484.7161 FAX:(203)484-7116 Quality System Cer6Eed to International Standard ISO-9001 FIrel-ITe ALarmS One Fire-Lite Place,Nonhford,Connecticut 06472 DF-50970— Page 1 of 3 5 Page 16 _ Page 17 HEIGHT 1 BELON! TOP VIEW 3.70±0.08inches o (94±2 mm) i HEIGHT 2 BELOW 3.66 t 0.08 inches , (96 t 2 mm) SEALED RECHARGEABLE BATTERY 1 BB-17F:Optional Battery Backbox 14-1/2"W x 8-1/4" H x 4-3/4" D SIDE 2 (mm: 368.3 W x 209.55 H x 120.65 D) MODEL PS-1278 VIEW For remote mounting of two 12-volt PS-12180 batteries. 12 VOLT 7,0 AMP. HOUR db 5.94±0.04 inches (161 t 1 mm) I 2.56±0.04 inches (65±1 mm) y io9Jmtrit BB-55F.Optional Battery Backbox ' See CHG-120F catalog sheet for details. ENGINEERING SPECIFICATIONS 8°S°bb55.wmf The fire control panel shall be equipped with secondary power provided by gelled-electrolyte batteries. The batteries shall be maintenance-free and shall be capable of powering the system in a manner and for a length of time determined by the governing regulations and the authority having jurisdiction. Nominal Discharge DIMENSIONS Capacity Current Height over Nominal @ @ Width Depth Height terminal Weight Voltage 20 hr.rate 20 hr.rate A MODEL V .H. mA in. mm. in. mm. in. mm. in. mm. lbs. kg.. PS-695 6 9.5 475 426 106 2.75 70 5.54 141 5.54 141 4.9 2.2 PS-1250 12 5.0 250 3.54 90 2.76 70 4.02 102 4.21 107 4.1 1.9 - PS-1270 12 7.0 325 5.94 151 2.56 65 3.70 94 3.86 98 5.7 2.6 PS-12120 12 12 600 5.94 151 3.86 98 3.70 94 3.86 98 8.8 4.0 PS-12180 12 18 875 7.13 181 2.99 76 6.57 167 6.57 167 12.8 5.8 PS-12250 12 25 1300 6.89 175 6.54 166 4.92 125 4.92 125 18.7 8.5 PS-12600 12 60 3000 10.25 J 260 6.60 168 8.20 206 9.45 240 39.7 18.0 PS421000 12 100 5000 12.00 305 6.60 168 8.20 2-08 9.45 240 65.7 29.8 sos CO3b; Characteristic Discharge Curves 120/°° Effect of Temperature on Capacity -�-; -- - -- - ------ 6.5 13100 o -- -0.5C s 6.0 12 Y� i t- 80% .- - -�---�{-- -0.25C 5.5-11 -- 10 5.0 0.'175C 0.5C Z' 60% __ I { __.1 ._ �- _ _---.i 1 C m 0.25C U r _s i 2 C a I 0° 4.5 9 osc 40°!0 « -- _ _ _; i _1✓ _ y [ 4.0 6 20% f. 3C 2C 1C 0 1 2 3 5 10 2030 60 2 3 5 10 20 30 0% so:gm.ii �- Mnucs -f----aours i -20" -10° 0° 10* 201 30' 40" 50' 60" Discharge Time @ 20`C(68"1`) 110eS r2.,.mi Temperature(Degrees C.) Page 2 of 3- DF-50970 6 Page 17 Page 18 PS-121000 RECHARGEABLE BATTERY: APPLICATIONS AND CHARGING CYCLE APPLICATIONS: Limit initial current to 20A. Charge until battery voltage(under charge)reaches 14.40 to 14.70 volts at 68°F(200C). Hold at 14.40 to 14.70 volts until current drops to approximately 1000 mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to"float"voltage. "FLOAT, OR "STAND-BY" SERVICE: Hold battery across constant voltage source or 13.50 to 13.80 volts continu- ously. When held at this voltage,the battery will seek its own current level and maintain itself in a fully charged position. NOTE. Due to the self-discharge characteristics of this type of battery,it is imperative that the battery be charged after six to nine months of storage, otherwise permanent loss of capacity might result from sulfation. 100% Charging is NOT ` 90% I necessary unless 100%of capacity f is required. 80% -- ; o ° ; •i Charging before ! 70% use is necessary to help recover i 60°/ _.. ! -- i j full capacity. y ° i t- - f — i 1 , o Charge may 50/o fail to restore U 40°C i 30°C j 200C �; full capacity. I 40% i (104°F) (86°F) (68°F) I DO NOT 1 let batteries E ' reach this state. f 0% ! ; 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) -. PS-121000 14.0 V Shelf-Life Ambient Temperature 20'C(68°F) 1 i and Storage 13.0 V -- _.---- — a 0 12.0 V - i i 5.0A1 ~ 9.0 v `- t . . - -—{- ' ' 50A1 P$-121000 Final 100A Voltage j ; ; ; I Discharge 8.0 V r— - 200A j �... - ,_---- - — -- i_ Characteristics 1.2 2.4 6 12 24 36 481 2 4 6 810 20 40 MINUTES ---x--•-----HOURS Discharge Time DF-50970—Page 3 of 3 7 Page 18 Page 1 DN-60548:132 LCD2-80 �J NOT 1 F 1 E R° Liquid Crystal Display Terminal Mode Annunciator by Honeywell Annunciators General The LCD2-80 is a backlit LCD annunciator for the NOTIFIER " fire alarm control panels,or network control annunciators that support the 80-character display format. LCD2-80s may be connected onto the four-wire EIA-485 terminal port. The LCD2-80 mimics the display of NFS2-640, NFS2-3030, t NFS-320, NCA-2 and legacy panels that supported the LCD- 80/LCD-80TM. The NFS2-3030 and the NCA-2 also support LCD2-80s when set for LCD-80 supervision. Up to 32 LCD2- i ALARM 80s can annunciate and provide remote reset, acknowledge, SUPERVISORY li,Q' drill and silence of the control panel from remote locations. I SYSTEM TROUBLE NOTE. The LCD2-80 can be used with legacy panels that sup- 5 POINTOISABLE ported the LCD-80 terminal mode operation. Please refer to the OGNALSILENGE .o P P I OTHER .e LCD2-80 manual for more information. ; Rv ACKN OWLEDGE Features ry SIGNAL SILENCE • 80-character backlit Liquid Crystal Display(20 characters x ;: ' RESET 4 lines). {'M:'� DRILL • Display mimics panel or NCA ° LAMPTEST m — Event message. CS — 20 characters for point label, o — 12 characters for extended label. U — Time,date and point address. • Control switches for System Acknowledge, Signal Silence Drill and System Reset. NOTE. The LEDs are only applicable when used with UL 864 • Up to 6000 foot segments between units. Ninth Edition listed panels.NFS-320, NFS2-640, NFS2-3030 and • Local piezo sounder with alarm/trouble resound. NCA-2. • Displays all analog,addressable points. • Flush/surface/panel mount option. • Displays device type identifiers. • No programming necessary. LCD2-80 displays time, date, Displays device and zone custom alpha labels. and custom messages received from the compatible panel • or network annunciator. • LCD2-80 mounts with any CHS-4 chassis slot. . LCD2-80 is 8.25"(20.96 cm)high,4.375"(11.11 cm)wide, • Slide-in label can be customized. and 1.75"(4.45 cm)deep. • LEDS for general off-normal events with UL 864 9th Edition . Up to 32 LCD2-80s may be used on one EIA-485 circuit. Panels. NOTE.Must have sufficient regulated 24 volt power. 6,000 ft(1828.8 m) Maximum wire length between each LCD2-80 EIA-485 (2 wires) O 24 VDC (2 wires) EIA-485 return(2 wires) NFS-320, NFS2-640, NFS2-3030, or NCA-2 connecting to LCD2-80 DN-60548:B2.05/25/12—Page 1 of 2 Page 19 Page 20 The A13F-1 DB Backbox ABF-2DB:Annunciator semi-flush mount backbox. Black with The ABF-1 DB is asemi-flush-mount backbox for the NOTI- a smoked glass door with a keylock. FIER LCD2-80 Series Annunciator.The ABF-1 DB mounts one AKS-1 B: Key Switch (black)to enable/disable controls when LCD2-80. It includes an attractive smoked-glass door with mounted in ABF-1 B or ABS-1 TB. NOTIFIER keylock. Dimensions,BOX only: Agency Listings and Approvals 9.938"(25.24 cm)high,4.625"(11.75 cm)wide,2.5"(6.35 cm) These listings and approvals apply to the modules specified in deep. this document.In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may Dimensions,DOOR only: be in process.Consult factory for latest listing status. 10.713"(27.21 cm)high,6.0"(15.24 cm)wide,0.75"(1.9 cm) . UL Listed:S635 deep. • ULC Listed:S635 Related Options • FDNY:COA#6067,6065 ABF-1 DB: Semi-flush box with alternative smoked-glass • CSFM:7165-0028:0243,7165-0028-0224FM Approved door,any keylock. ADP-413: Annunciator dress plate,black.Allows panel mount- ing of up to four LCD2-80 modules in a CAB-4 Series cabinet. ABF-1 B: Annunciator flush box, 9.938" (25.24 cm) high, 4.625"(11.75 cm)wide,and 2.5"(6.35 cm)deep.Order AKS- 1 B key switch and APJ-1 B phone jack if desired. Can also be mounted in ABF-213 or ABF-413 annunciator backboxes. ABS-iTB: Deep surface backbox(mounts one LCD2-80). ABS-213: Annunciator surface box, 8.5" (21.59 cm) high x 8.92"(22.66 cm)x 2"(5.08 cm)deep. Knockouts are provided for use with 1/2" (1.27 cm) conduit. The annunciators mount directly to the ABS-213 without a dress plate. ABS-2D:Annunciator backbox,surface,black. ABF-2B: Annunciator flush box, 9.938" (25.24 cm) high x 9.188" (23.34 cm) wide x 3.75" (9.525 cm) deep. Includes a painted metal trim plate[11"(27.94 cm)high x 10.625"(26.99 cm)wide]and adhesive-backed annunciator label. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MCINEUIINC i MAMWA611MNG All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-60548:132.05/25/12 Page 20 Page 21 �J NOTI FI E R° by Honeywell PSE-6/PSE-10 Series 6/10 Amp, 24 Volt Power Supply Expanders General The PS Series is a remote power supply line from NOTIFIER and is a direct replacement for the FCPS-24S6/8 Series.The PSE-6(C)(E) is a 6 amp and the PSE-10(C)(E)is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs(notification appli- ance circuits) configured as either Class B or Class A(requires the ZNAC-PS option card)with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm sys POWERSUPPLY - tem peripherals.The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabi- net. The PSE-6E and PSE-10E are models rated for 240V opera- tion. Features • Up to five (6 amp model) or seven (10 amp model) inde- pendently-configurable,power-limited output circuits for: —Class B and/or Class A NACs —Class B and/or Class A resettable or non-resettable 24V auxil- iary power —door holder power • Converts from Class B to Class A wiring without losing any out- Battery charger may be disabled via DIP switch for applications puts using the ZNAC-PS converter card(sold separately) requiring larger batteries and external battery charger • Optimal for powering four-wire smoke detectors, annunciators, Removable terminal blocks accommodate up to 12 AWG and other system peripherals requiring regulated power (3.1mm2)wire • Configurable forANSIO Temporal 3 or Temporal 4 coded output Works with any UL 864 FACP which utilizes an industry-standard • UL-Listed NAC synchronization using System Sensor®, Whee- reverse-polarity notification circuit lock®,Gentex®,orAMSECO®appliances Optional devices include addressable control, monitor, and relay • Synchronization can be triggered from FACP NAC/remote sync modules and power-supervision relay(EOLR-1) outputs, cascaded power supply, or a control module, single or multi,which may be housed within the power supply cabinet Standards and Codes • Ability to cascade up to four power supplies • Two(6 amp model)or three(10 amp model)fully-isolated input/ The PSE Series comply with the following standards: control circuits which can be programmed to any output NFPA 72 National Fire Alarm Code • Two Form C normally-closed trouble relays for AC Trouble and UL 864 Standard for Control Units for Fire Alarm Systems(NAC General Trouble,Ground Fault relay available on Canadian mod- expander mode), 10th Edition els only UL 1481 Power Supplies for Fire Alarm Systems • 6 or 10 amp full load output, respectively,with 3 A maximum/cir- IBC 2009(when using SEISKIT-MULTI-1) cult CBC 2007(when using SEISKIT MULTI-1) • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history modes for diagnostic support Agency Listings and Approvals • Wide range end-of-line supervision value(normal:2K-27K ohms) These listings and approvals apply to the modules specified in this • Selectable earth fault detection(enable or disable) document. In some cases, certain modules or applications may not • AC trouble report delay timer be listed by certain approval agencies, or listing may be in process. • Completely configurable via onboard DIP switches, no extra soft- Consult factory for latest listing status. ware required • UL Listed:S635,S674 • Self-contained in compact, locking cabinet constructed of heavy • ULC Listed:S635(PSE-6/10C) gauge steel with a corrosion-resistant powder coat chip and . CSFIVI Approved:7315-0028:0513 scratch-resistant finish • FDNY Approved • Cabinet designed with ten double knockouts and a removable • FM Approved door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries Page 21 DN-61092:C•3/10/2021—Page 1 of 2 SPECIFICATIONS Page 22 Primary(AC)Power: Ordering Information • PSE-6(C): 120 VAC,50/60 Hz,5.OA maximum PSE-6: 6.0 A, 120 VAC remote charger power supply in a lockable, • PSE-10(C): 120VAC,50/60 Hz,6.2 A maximum metal enclosure • PSE-6E:240 VAC,50/60 Hz,2.7A maximum PSE-6C: Same as above,ULC-listed model • PSE-10E:240 VAC,50/60 Hz,3.5A maximum PSE-6R: Same as PSE-6 with red enclosure • Wire Size:#12-14 AWG with 600 V insulation PSE-6E: 6.0 A, 240 VAC remote charger power supply in a lock- Command Input Circuit: able,metal enclosure • Trigger Input Voltage:9 to 32 VDC PSE-10: 10.0 A, 120 VAC remote charger power supply in a lock- • Trigger Current:2.0 mA(16-32 V);Per Input: 1.0 mA(9-16 V) able,metal enclosure Trouble Contact Rating: 4 A at 24 VDC PSE-10C: Same as above, ULC-listed model Output Circuits: PSE-1 OR: Same as PSE-10 with red enclosure • 24 VDC filtered,regulated PSE-1 OE: 10.0 A,240 VAC remote charger power supply in a lock- • PSE-6:T138-TB9—1A Regulated,3A special applications;TB10- able,metal enclosure TB12—0.3A Regulated,3A special applications ZNAC-PS: Optional Class A output converter module • PSE-10: TB8-TB11 — 1.5A Regulated, 3A special applications; FCM-1: Addressable Control Module for one Class B or Class A TB12-TB14—0.3A Regulated,3A special applications zone of supervised, polarized Notification Appliances. Notification • 6.0 A(PSE-6)or 10.0 A(PSE-10)maximum total continuous cur- Appliance Circuit option requires external 24 VDC to power notifica- rent for all outputs tion appliances. Secondary Power(Battery)Charging Circuit: FRM-1: Addressable relay module containing two isolated sets of • Supports lead-acid batteries only Form-C contacts,which operate as a DPDT switch • Float-charge voltage:27.6 VDC FMM-1:Addressable Monitor Module for one zone of normally open • Maximum current charge: 1.5A dry-contact initiating devices. Includes plastic cover plate and end- • Maximum battery capacity: 18AH(inside cabinet) of-line resistor. Module may be configured for either a Class B or Class A IDC. • Maximum battery charging capacity:33 AH(external cabinet) Physical: FDM-1: Dual Monitor Module. Same as FMM-1 except it provides y two inputs for Class B wiring only • Dimensions: 20.0"H x 14.5"W x 3.5"D (cm: 50.81-1 x 36.83W x FDRM-1: Provides two monitored inputs and two Form-C relays. 8.9D) Functions in Class B wiring only. • Weight:with two 7Ah batteries is 24 pounds (10.9 kg),with two XP6-C:Six-circuit supervised control module 18AH batteries is 39 pounds(17.7 kg) XP6-R:Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required, see BAT Series data sheet DN-6933). BAT-12180-BP: Battery, 12 volt, 18AH,2-pack BAT-12330: Battery, 12 volt,33AH SEISKIT-MULTI-1: Seismic kit for the PSE Series.Includes bracket and hardware for two 7AH or two 18AH batteries. ISO 9001 @Jilts®Ih6 i NRIRACIIUi QUAILITT SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIERO and System Sensor®are registered trademarks of Honeywell International,Inc.Wheelock®is a registered trademark of Cooper Tech- N OTI F I E R nologies Company.Gemex@ is a registered trademark of Gentex Corpora- tion.AMSECOG is a.registered trademark of Potter Bechic Signal 12 Clintonville Road Company,LLC.ANSI®is a registered trademark of the American National �� O Northford,CT 06472 Standards Institute,Inc. NOT 1 F 1 E R 203.484.7161 02021 by Honeywell International Inc.Ali rights reserved.Unauthorized use of this document is strictly prohibited by Honeywell www riotifier.com Country of Origin:USA Page 22 Page 23 �J NOTIFIER by Honeywell FSP-951 Series Addressable Photoelectric Smoke Detectors The NOTIFIERO FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the FSP-851 Series. A new modern, sleek, con- temporary design and enhanced optical sensing chamber is engi- neered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing = exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 1350F(57°C)fixed temperature thermal sensing on j \ the FSP-951T.The FSP-951 R is a remote test capable detector for use with DNR Series duct detector housings.FSP-951 series detec- tors are available for both FlashScanO and CLIP applications as designated. f\. Features SLC LOOP: Separate base allows interchange of photoelectric,ionization and • Two-wire SLC loop connection thermal sensors • Unit uses base for wiring OPTIONS: • Compatible with FlashScan®and CLIP protocol systems • Optional relay,isolator,and sounder bases • Stable communication technique with noise immunity Installation ADDRESSING: FSP-951 Series plug-in intelligent smoke detectors use a detach- Addressable by device able base to simplify installation, service and maintenance. Installa- • Rotary,decimal addressing tion instructions are shipped with each detector. (Refer to the NOTIFIER panel manuals for device capacity.) Mount detector base(all base types)on an electrical backbox which ARCHITECTURE. is at least 1.5" (3.81 cm) deep. For a chart of compatible junction • Sleek,low-profile,stylish design boxes,see DN-60054. • Unique single-source design to respond quickly and dependably NOTE.Because of the inherent supervision provided by the SLC loop, to a broad range of fires end-of-line resistors are not required. Wiring `T-taps"or branches are permitted for Class`B"wiring only. • Integral communications and built-in device-type identification When using relay or sounder bases, consult the ISO-X(A) installation • Built-in tamper resistant feature sheet 156-1380 for device limitations between isolator modules and isola- Remote test feature from the panel for bases. • Walk test with address display (an address on 121 will blink the Construction detector LED: 12-[pause]-1(FlashScan systems only) These detectors are constructed of fire-resistant plastic. The FSP- • Built-in functional test switch activated by external magnet 951 Series plug-in intelligent smoke detectors are designed to com- • Removable cover and insect-resistant screen for simple field mercial standards and offer an attractive appearance. cleaning • Expanded color options Operation OPERATION: Each FSP-951 Series detector uses one of the panel's addresses Designed to meet UL 268 7th Edition (total limit is panel dependent)on the NOTIFIER Signaling Line Cir- • cuit (SLC). It responds to regular polls from the control panel and • Factory preset at 1.5%nominal sensitivity for panel alarm thresh- reports its type and the status.If it receives a test command from the old level panel (or a local magnet test), it stimulates its electronics and • LED"blinks"when the unit is polled (communicating with the fire reports an alarm. It blinks its LEDs when polled and turns the LEDs panel)and latches in alarm. on when commanded by the panel.The FSP-951 Series offers fea- • Low standby current tures and performance that represent the latest in smoke detector technology. MECHANICALS: • Sealed against back pressure Product Line Information • SEMS screws for wiring of the separate base NOTE."--IV"suffix indicates CLIP and F/ashScan device. • Designed for direct-surface or electrical-box mounting FSP-951:White,low-profile intelligent photoelectric sensor,FlashS- • Plugs into separate base for ease of installation and maintenance can only FSP-951A:Same as FSP-951 but with ULC listing Page 23 DN-609770•8/13/2020—Page 1 of 3 Page 24 FSP-951-IV: Ivory,low-profile intelligent photoelectric sensor B200SCOA-IV: Ivory Intelligent, programmable sounder base in FSP-951A-IV:Same as FSP-951-IV but with ULC listing English/French (required in Canada for ULC applications with CO Series detector applications,ULC.listing FSP-951T: White, same as FSP-951 but includes a built-in 135°F B20OS-LF-WH: White, Low Frequency Intelligent, programmable (57°C)fixed-temperature thermal device,FlashScan only sounder base. Produces a fundamental frequency of 520 Hz +/- FSP-951TA:Same as FSP-951T but with ULC listing 10% with a square wave or its equivalent; designed to meet the FSP-951T4V:Ivory,same as FSP-951T but includes a built-in 135OF NFPA 72 sleeping space requirement.(CSFM:7300-1653.0238) (57°C)fixed-temperature thermal device B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- FSP-951TA-IV:Same as FSP-951T-IV but with ULC listing 10% with a square wave or its equivalent; designed to meet the FSP-951R: White, low-profile intelligent photoelectric sensor, NFPA 72 sleeping space requirement.(CSFM:7300-1653.0238) remote test capable,for use with DNR/DNRW,FlashScan only B200SR-WH:White, Intelligent sounder base capable of producing FSP-951RA: Same as FSP-951 R but with ULC listing, for use with sound output with ANSI Temporal 3 or continuous tone.Intended for DNRA retrofit applications. (CSFM:7300-1653.0213) FSP-951R-IV: Ivory, low-profile intelligent photoelectric sensor, 13200SR-IV: Ivory, Intelligent sounder base capable of producing remote test capable,for use with DNR/DNRW sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM:7300-1653:0213) FSP-951 RA-IV:Same as FSP-951 R-IV but with ULC listing,for use B200SRA-WH:Same as B200SR-WH with,ULC listing with DNRA B200SRA-IV:Same as B200SR-IV in Ivory color,ULC listing INTELLIGENT BASES B200SR-LF-WH: White, Low Frequency Intelligent, programmable NOTE:For details on intelligent bases,see DN-60981. sounder base. Produces a fundamental frequency of 520 Hz +/- B300-6:White,6"base,standard flanged low-profile mounting base 10% with a square wave or its equivalent; designed to meet the (CSFM:7300-1653:0109) NFPA 72 sleeping space requirement. Intended for retrofit applica- B300-64V: Ivory,6" base, standard flanged low-profile mounting tions.(CSFM:7300-1653.0238) base(CSFM:7300-1653:0109) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable B300A-6:Same as B300-6,ULC listed sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the B30OA-6-IV: Ivory, 6" standard flanged low-profile mounting base, NFPA 72 sleeping space requirement. Intended for retrofit applica- ULC listed tions.(CSFM:7300-1653.0238) B300-6-BP:Bulk pack of B300-6,package contains 10 MOUNTING KITS AND ACCESSORIES B501-WHITE: White, V standard European flangeless mounting TR300:White,replacement flange for B210LP(A)base base.UUULC listed(CSFM:7300-1653:0109) TR300-IV:Ivory,replacement flange for B210LP(A)base B501-BL: Black, 4" standard European flangeless mounting base. RA100Z(A):Remote LED annunciator.3-32 VDC. Mounts to a U.S. UUULC listed(CSFM:7300-1653:0109) single-gang electrical box.For use with B501(A)and B300-6(A). B501-IV: Ivory color, 4" standard European flangeless mounting base.UUULC listed(CSFM:7300-1653:0109) M02-04-00:Test magnet B501-WHITE-BP:Bulk pack of B501-WHITE contains 10 M02-09-00:Test magnet with telescoping handle B224RB-WH:White,relay base(CSFM:7300-1653:0216) CK300:Color Kit(includes cover and trim ring),white, 10-pack B224RB-IV: Ivory,relay base(CSFM:7300-1653.0216) CK300-IV:Color Kit(includes cover and trim ring),ivory, 10-pack 121224RBA-WH:White,relay base,ULC listing CK300-BL:Color Kit(includes cover and trim ring),black, 10-pack B224RBA-IV: Ivory,relay base,ULC listing B224BI-WH:White,isolator detector base(CSFM:7300-1653:0216) B224BI-IV:Ivory isolator detector base(CSFM:7300-1653:0216) B224BIA-WH:White,isolator detector base,ULC listing B224BIA-IV:Ivory isolator detector base,ULC listing B20OS-WH:White,Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653.0213) B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653.0213) B200SA-WH:Same as B200S-WH,ULC listing B200SA-IV:Same as B200S-IV,ULC listing B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications Page 2 of 3—1314-60977:13-8/13/2020 Page 24 SPECIFICATIONS Page 25 Sensitivity: Listings and Approvals • UL Applications:0.5%to 4.0%per foot obscuration. Listings and approvals below apply to the FSP-951 Series detectors. • ULC Applications:0.5%to 3.5%per foot obscuration In some cases, certain modules may not be listed by certain Size:2.0"(51 mm)high;base determines diameter approval agencies, or listing may be in process. Consult factory for —B300-6 series:6.1"(15.6 cm)diameter latest listing status. —B501 series:4"(10.2 cm)diameter • UL/ULC Listing:S1115 For a complete list of detector bases see DN-60981 • FM Approved • CSFM:7272-0028:0503 Shipping weight:3.4 oz.(95 g) Operating temperature range: • FSP-951 Series:32°F to 122°F(0°C to 50°C) • FSP-951T Series:32°F to 100°F(0°C to 38°C) • FSP-951 R Series installed in DNR/DNRA/DNRW,-4°F to 158°F (-20oC to 70oC) UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts Relative humidity:10%—93%non-condensing Thermal ratings:fixed-temperature set point 1350F(57°C),rate-of- rise detection 15°F(8.3°C)per minute,high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current(max.avg.): 200pA @ 24 VDC(one communica- tion every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet(9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide,document SPAG91, is available at www.systemsensor.com. ISO 9001 UILIP®1�6111WIfAlllfl�i QUSEITY SYSTEMS This document Is not intended to be used for installation purposes. We try to keep our product Information updo-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice, NOTIFIER Flas ,N01I1FIEI9,and System Sensor®are registered trade• 12 Clintonville Road marks of Honeywell International,Inc. �� Northford,CT 06472 (�M0 by Honeywell Irdemafttal Inc.All rights reserved.Unauthorized O NOT 1 F 1 E R 203.484.7161 useofthsdocumentissti�lyprohibite. by Honeywell www.notifier.com Country of origin:Mexico Page 25 Page 26 �J NOTIFIER 0 by Honeywell (FST-951 Series Intelligent Addressable Heat Detectors The NOTIFIERO FST 951 Series intelligent thermal detectors are designed for both performance and aesthetics, and are direct replacements for the FST-851 Series.A new modern, sleek, con- temporary design and advanced thermal technologies make the FST 951 Series ideal for both system operation and building design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 135•F/57•C fixed-temperature, rate-of-rise, and a 190•F/88°C fixed high-temperature detectors.These thermal detectors provide effective,intelligent property protection in a varietyof applications. Detectors are available for both FlashScan® and CLIP applications as designated. ` Features SLC LOOP: \ • Two-wire SLC loop connection • Unit uses base for wiring ADDRESSING: Installation • Addressable by device FST-951 Series plug-in intelligent thermal detectors use a detach- Rotary,decimal addressing able base to simplify installation, service and maintenance. Installa- (Refer to the NOTIFIER panel manuals for device capacity.) tion instructions are shipped with each detector. ARCHITECTURE: Mount detector base(all base types)on an electrical backbox which • Designed to meet UL 268 7th Edition is at least 1.5" (3.81 cm) deep. For a chart of compatible junction • Sleek,low-profile,stylish design boxes,see DN-60054. NOTE.Because of the inherent supervision provided by the SLC loop, • State-of-the-art thermistor technology for fast response end-of-line resistors are not required. tiring "T-taps"or branches are • Integral communications and built-in device-type identification permitted for Style 4(Class B')wiring only. • Built-in tamper resistant feature When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and iso- • Built-in functional test switch activated by external magnet lator bases. OPERATION: • Fixed temperature model (FST-951) factory preset to 135•F Applications (57•C) Use thermal detectors for protection of property.For further informa- • Rate-of-rise model(FST-951 R),15•F(8.3•C)per minute tion, refer to 156-6522, Applications Manual for System Smoke • High-temperature model FST-951 H) factory preset to 190°F Detectors,which provides detailed information on detector spacing, (88,C) placement,zoning,wiring,and special applications. • 360•-field viewing angle of the two visual alarm indicators, LEDs Construction blink red in Normal condition and turn on steady red in Alarm • LEDs blink every time the unit is polled These detectors are constructed of fire-resistant plastic. The FST 951 Series plug-in intelligent thermal detectors are designed to com- MECHANICALS: mercial standards and offer an attractive appearance. • Sealed against back pressure • SEMS screws for wiring of the separate base Operation • Designed for direct-surface or electrical-box mounting Each FST-951 Series detector uses one of the panel's addresses • Plugs into separate base for ease of installation and maintenance (total limit is panel dependent)on the NOTIFIER Signaling Line Cir- • Separate base allows interchange of photoelectric,ionization and cuit (SLC). It responds to regular polls from the control panel and thermal sensors reports its type and the status.If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and OTHER SYSTEM FEATURES: reports an alarm. It blinks its LEDs when polled and turns the LEDs • Remote test feature from the panel on when commanded by the panel.The FST 951 Series offers fea- tures and performance that represent the latest in thermal detector technology. • Low standby current OPTIONS: • Remote LED output connection to optional RA100Z remote LED annunciator Page 26 DN-60975:B•6/26/2019—Page 1 of 3 Page 27 Product Line Information B200SCOA-WH:White, Intelligent, programmable sounder base in NOTE:"-IV"suffix indicates CLIP and FlashScandevice. English/French (required in Canada for ULC applications with CO Series detector applications FST-951: White, low-profile intelligent 135°F fixed thermal sensor, B200SCOA-IV: Ivory Intelligent, programmable sounder base in FlashScan only English/French (required in Canada for ULC applications with CO FST-951A:Same as FST 951 but with ULC listing Series detector applications,ULC listing FST-951-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, B200S-LF-WH: White, Low Frequency Intelligent, programmable FlashScan and CLIP sounder base. Produces a fundamental frequency of 520 Hz +/- FST-951A-IV:Same as FST-951-IV but with ULC listing 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) FST-951R: White, low-profile intelligent rate-of-rise thermal sensor, B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable FlashScan only sounder base. Produces a fundamental frequency of 520 Hz +/- FST-951RA:Same as FST-951 but with ULC listing 10% with a square wave or its equivalent; designed to meet the FST-951R-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal NFPA72 sleeping space requirement.(CSFM:7300-1653:0238) sensor,FlashScan and CLIP B200SR-WH:White, Intelligent sounder base capable of producing FST-951 RA-IV:Same as FST-951 R-IV but with ULC listing sound output with ANSI Temporal 3 or continuous tone.Intended for FST-951 H:White, low-profile intelligent 190°F fixed thermal sensor, retrofit applications.(CSFM:7300-1653:0213) FlashScan only B200SR-IV: Ivory, Intelligent sounder base capable of producing FST-951 HA:Same as FST-951 H but with ULC listing sound output with ANSI Temporal 3 or continuous tone.Intended for retrofit applications.(CSFM.7300-1653:0213) FST-951H-IV: Ivory, low-profile intelligent 190°F thermal sensor, B200SRA-WH:Same as B200SR-WH with, ULC listing FlashScan and CLIP FST-951 HA-IV Same as FST-951 but with ULC listing 6200SRA-IV:Same as B200SR-IV in Ivory color,ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable INTELLIGENT BASES sounder base. Produces a fundamental frequency of 520 Hz +/- NOTE.For details on intelligent bases,see DN-60981. 10% with a square wave or its equivalent; designed to meet the B300-6:White,6°base,standard flanged low-profile mounting base NFPA 72 sleeping space requirement. Intended for retrofit applica- (CSFM:7300-1653:0109) tions.(CSFM:7300-1653:0238) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable base(CSFM:7300-1653:0109) sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the B300A-6:Same as B300-6,ULC listed NFPA 72 sleeping space requirement. Intended for retrofit applica- B30OA-6-IV: Ivory, 6" standard flanged low-profile mounting base, tions.(CSFM:7300-1653:0238) ULC listed MOUNTING KITS AND ACCESSORIES B300-6-BP:Bulk pack of B300-6,package contains 10 TR300:White, replacement flange for B210LP(A)base B501-WHITE: White, 4" standard European flangeless mounting TR300-IV:Ivory,replacement flange for B210LP(A)base base. UUULC listed(CSFM:7300-1653:0109) RA1OOZ(A):Remote LED annunciator.3-32 VDC.Mounts to a U.S. B501-BL: Black, 4" standard European flangeless mounting base. single-gang electrical box.For use with B501(A)and B300-6(A). UL/ULC listed(CSFM:7300-1653:0109) M02-04-00:Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting base.UL/ULC listed(CSFM:7300-1653:0109) M02-09-00:Test magnet with telescoping handle B501-WHITE-BP:Bulk pack of B501-WHITE contains 10 CK300:Color Kit(includes cover and trim ring),white, 10-pack B224RB-WH:White,relay base(CSFM:7300-1653:0216) CK300-IV:Color Kit(includes cover and trim ring),ivory, 10-pack B224RB-IV: Ivory, relay base(CSFM:7300-1653:0216) CK300-BL:Color Kit(includes cover and trim ring),black, 10-pack B224RBA-WH:White,relay base,ULC listing B224RBA-IV: Ivory,relay base,ULC listing B224BI-WH:White,isolator detector base(CSFM:7300-1653:0216) B224BI-IV: Ivory isolator detector base(CSFM:7300-1653:0216) B224BIA-WH:White,isolator detector base,ULC listing B224BIA-IV: Ivory isolator detector base,ULC listing B200S-WH:White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653:0213) B200SA-WH:Same as B200S-WH,ULC listing B200SA-IV:Same as B200S4V,ULC listing Page 2 of 3—DN-60975:B-6/26/2019 Page 27 SPECIFICATIONS Page 28 Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC is 0.5%to 3.5% Size:2.0"(5.3 cm)high;base determines diameter —B300-6:6.1"(15.6 cm)diameter —B501:4"(10.2 cm)diameter For a complete list of detector bases see DN-60981 Shipping weight:3.4 oz.(95 g) Operating temperature range: • FST-951,FST-951R Series:—4*F to 100•F(-20•C to 38•C) • FST-951 H Series:—4•F to 150•F(-20•C to 66•C) Detector spacing: UL approved for 50 ft. (15.24 m)center-to-cen- ter,FM approved for 25 x 25 ft.(7.62 x 7.62 m)spacing Relative humidity: 10%—93%non-condensing Thermal ratings:fixed-temperature set point 135°F(57•C),rate-of- rise detection 15•F(8.3•C)per minute,high temperature heat 190•F (88•C) Mounting:B300-6(A)flanged base,included See"Product Line Information: Intelligent Bases,"if using a dif- ferent base. ELECTRICAL SPECIFICATIONS Voltage range:15-32 volts DC peak Standby current(max.avg.):200pA @ 24 VDC(one communica- tion every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") Listings and Approvals Listings and approvals below apply to the FST 951 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC Listing:S747 • FM Approved • CSFM:7270-0028:0502 ISO 9001 BILI@®If6 6 AIIWIfI[INi QUAILITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-t ate and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER Flash5prr0 and NOTIFIER®are registered trademarks of Honeywell 12 Clintonville Road bdemationakIx Northford,CT 06472 @2019 by Honeywell International Inc.Ali rights reserved.Unauthorized �J NOT 1 F 1 E R 203.484.7161 use of this document is stdctly prolLroited. by Honeywell www.notifier.com Country of Origin:Mexico Page 28 Page 29 �J NOTI FI E R° 0 by Honeywell Intelligent BaSeS Standard, Relay, Isolator, Sounder, and Low-Frequency Sounder Bases General _ To meet local code and application requirements,NOTIFIERO offers standard 4"and 6"bases,as well as,specialty base designs includ- ing relay, isolator, sounder and low frequency sounder options for O � ' the new 900 Series of addressable detectors as well as previous generations. L" The standard 4"and 6"bases offer a plug-in detector base intended O \, ■■ for use in intelligent systems, with screw terminals identified with a (+ and—). The 4" base offers a compact design while the 6" base � provides compatibility with a wider range of junction boxes. B20oS-WH B300-6 Standard The specialty bases support application driven requirements.These 6"Base(White) Sounder Base(White) bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation. .... ` Relay bases provide one form-C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can I operate in two different modes(short and long delay).The activation time for the short delay is 60-100 milliseconds, while the activation time for the long delay is 6-10 seconds.A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases allow the Signaling Line Circuit(SLC)loop to operate under fault conditions created from a short circuit preventing an B501-WHITE Flangeless B501-BL Flangeless entire communication loop from being disabled. The base isolates 4°Base(White) 4"Base(Black) the section of the loop containing the short circuit from the remain- der of the circuit and automatically restores when the fault is cor- rected. Specifications Sounder and low frequency sounder bases are designed for new NOTE.Specifications applies to all model variants`A","-BL'; `=LF","-IV", and existing dwelling unit applications.They offer maximum flexibil- -WH,-WHITE.See Product Line Information for detailed model descrip- ity in installation,configuration,and operation to meet or exceed UL tion. 268 and UL 464 requirements. The low frequency sounder bases Diameter are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz+/- 10%with a square B501-WHITE:4"(10.16 cm)diameter. wave or its equivalent. Studies show that a lower frequency, cen- B300-6:6.1"(15.49 cm)diameter. tered around 520 Hz, is the most ideal to wake sleeping occupants, 1322413I,B224RB:6.2"(15.748 cm)diameter. even those with mild to severe hearing loss. B200S,B200SR,B200SCOA:6.875"(17.46 cm)diameter. The B200SR sounder and -LF sounder bases (B200SR-WH/ Wire gauge: B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501 BH Series sounder base installations.The device B224BI,B224RB: 14 to 24 AWG. enables users to select one of two B501-supported .tones (ANSI B300-6, B210LP, B501, B200S, B200SR, B200SCOA: 12 to 24 Temporal 3 or Continuous)through a jumper. AWG The B200S sounder and-LF sounder bases(B200S-WH/B200S-IV/ Temperature range: B200S-LF-WH/B200S-LF-IV)adopt the same address as the detec- 1322413I, B224RB, B200S, B200SR, B200SCOA: 32°F to 120°F tor,but use a unique device type on the loop.The Fire Alarm Control (0°C to 49°C). Panel (FACP) can use that address to command an individual B300-6,B210LP,B501:-4°F to 150°F(-20°C to 66°C). sounder—or a group of sounders—to activate.The command set from the FACP can be tailored to multiple event-driven tone outputs Humidity range: 10%to 93%RH,non-condensing. allowing selection of volume(75 or 85 dBA),tone(ANSI Temporal 3, System temperature and humidity ranges: This system meets ANSI Temporal 4, or March Time) and group. In addition, some NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); FACPs will enable custom tone patterns.The B200S series sounder and at a relative humidity(non-condensing)of 85% at 30°C (86°F) bases recognize the System Sensor synchronization protocol.This per NFPA,and 93%t 2%at 32°C f 2°C(89.6°F t 1.1°F)per ULC. enables them to be used as a component of the general evacuation However, the useful life of the system's standby batteries and the signal —along with other System Sensor AV appliances —when electronic components may be adversely affected by extreme tem- connected to a power supply or FACP output capable of generating perature ranges and humidity. Therefore, it is recommended that the System Sensor synchronization pulses. this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C(60°F to 80°F). Page 29 DN-60054:K•7/18/2018—Page 1 of 3 Page 30 Electrical Ratings Product Line Information FOR B300-6 SERIES BASES: INTELLIGENT BASES Operating voltage:15 to 32 VDC NOTE:`A"suffix indicates ULC Listed model. Standby current: 170 pA maximum NOTE:=IV"suffixindicates Ivory color model. FOR B501 SERIES BASES: NOTE. "BL"suffix indicates Black color model. Operating voltage: 15 to 32 VDC NOTE. "-WH"and"WHITE"suffix indicates White color model. Standby current: 150 pA maximum B21 OLP:Flanged mounted base. B210LPA:Same as B210LP;ULC listed. FOR 6200 SERIES BASES: B210LPBP:Bulk pack of 6210LP,contains 10. External supply voltage: 16 to 33 VDC(FWR) Standby current: B300-6:White,6"base,standard flanged low-profile mounting base. 500 NA maximum. 6300A-6:Same as B300-6,ULC listed. Alarm current: B300-6-BP: Bulk pack of B300-6,package contains 10;. • B200S(A)(-IV)(-WH) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base. —35 mA maximum at high-volume setting B300A-64V: Ivory, 6" standard flanged low-profile mounting base, —15 mA maximum at low-volume setting ULC listed. • B200S-LF(-IV)(-WH)High-volume setting: B501-WHITE: White, 4" standard European flangeless mounting —70 mA maximum @ 33.0 VDC base.UUULC listed. —90 mA maximum @ 24.0 VDC B501-WHITE-BP:Bulk pack of B501-WHITE contains 10. —140 mA maximum @16.0 VDC B501-BL: Black, 4" standard European flangeless mounting base. • B200S-LF(-IV)(-WH)Low-volume setting: UUULC listed. ' —15 mA maximum @ 33.0 VDC B5014V: Ivory color, 4" standard European flangeless mounting —20 mA maximum @ 24.0 VDC base.UUULC listed. —25 mA maximum @ 16.0 VDC B224RB-WH:White,relay base. • B200SR(A)(-IV)(-WH) B224RB-IV:Ivory, relay base. —35 mA maximum B224RBA-WH:White, relay base,ULC listed. • B200SR-LF(-IV)(-WH) B224RBA-IV:Ivory,relay base,ULC listed. —65 mA maximum @ 33.0 VDC —90 mA maximum @ 24.0 VDC B224BI-WH:White,isolator detector base. —125 mA maximum @16.0 VDC B224BI-IV: Ivory isolator detector base. • B200SCOA(-IV)(-WH) B224BIA-WH:White,isolator detector base, ULC listed. —40mA Max(DC) B224BIA-IV:Ivory isolator detector base,ULC listed. —70mA Max(FWR) B20OS-WH:White, Intelligent addressable sounder base capable of SLC operating voltage: 15 to 32 VDC producing sound output in high or low volume with ANSI Temporal 3, SLC standby current:See applicable sensor specification. ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan@ protocol. Sound output: B200S-IV:.Ivory, Intelligent addressable sounder base capable of • B200S(A)(-LF)(-IV)(-WH), high-volume*: Greater than 85 dBA producing sound output in high or low volume with ANSI Temporal 3, minimum. ANSI Temporal 4,continuous tone,marching tone,and custom tone. • B200S(A)(-LF)(-IV)(-WH), low-volume*: Greater than 75 dBA Uses FlashScan@ protocol. minimum. B200SA-WH:Same as B200S-WH, ULC listed. • B200SR(A)(-LF)(4V)(-WH)*:Greater than 85 dBA minimum. B200SA-IV:Same as B200S-IV,ULC listed. • B200SCOA(-IV)(-WH), high-volume**:Greater than 87 dBA mini- B200SCOA-WH:White, Intelligent, programmable sounder base in mum. English/French (required in Canada for ULC applications with SO • B200SCOA(-IV)(-WH), low-volume—: Greater than 85 dBA mini- Series detector applications. mum 'Measured in a UL reverberant room at 10 feet,24 Volts(continuous tone) B200SCOA-IV: Ivory Intelligent, programmable sounder base in **Measured in a ULC anechoic room at 10 feet,24 Volts continuous tone) English/French (required in Canada for ULC applications with SO Series detector applications,ULC listing. FOR B224B/,B224RB(A)(410(-WH): B20OS-LF-WH: White, Low Frequency Intelligent, programmable Operating voltage: 15 to 32 VDC(powered by SLC) sounder base. Produces a fundamental frequency of 520 Hz +/- Standby ratings:<450 pA maximum @ 24 VDC 10% with a square wave or its equivalent; designed to meet the Set time B224RBA IV -WH only):short delay 60-100 millisec- NFPA 72 sleeping space requirement. ( ( )( o ) y B20OS-LF-IV: No Low Frequency Intelligent, programmable onds;long delay 6-10 seconds Ivory, q Y 9 P 9 sounder base. Produces a fundamental frequency of 520 Hz +/- Reset time(B224RB(A)(-IV)(-WH)only):20 milliseconds maximum 10% with a square wave or its equivalent; designed to meet the Relay characteristics(B224RB(A)(4V)(-1NH)only):two-coil latch- NFPA 72 sleeping space requirement. ing relay;one Form-C contact;ratings(UUCSA):0.9 A @ 125 VAC, 0.9 A @ 110 VDC,and 3.0 A @ 30 VDC Page 2 of 3—DN-60054:K•7/18/2018 Page 30 Page 31 B200SR-WH:White, Intelligent sounder base capable of producing M02-04-00:Test magnet. sound output with ANSI Temporal 3 or continuous tone.Intended for M02-09-00:Test magnet with telescoping handle. retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing CK300:White,detector color kit.Pack of 10. sound output with ANSI Temporal 3 or continuous tone. Intended for CK300-IR: White, detector color kit for use with FPTI and FCO retrofit applications. I Series detectors.Pack of 10. B200SRA-WH:Same as B200SR-WH,ULC listed. CK300-IV:Ivory,detector color kit.Pack of 10. B200SRA-IV:Same as B200SR-IV in Ivory color,ULC listed. CK300-IR-IV: Ivory, detector color kit for use with FPTI and FCO B200SR-LF-WH: White, Low Frequency Intelligent, programmable Series detectors.Pack of 10. sounder base. Produces a fundamental frequency of 520 Hz +/- CK300-BL:Black,detector color kit. Pack of 10. 10% with a square wave or its equivalent; designed to meet the CK300-IR-BL: Black, detector color kit for use with FPTI and FCO NFPA 72 sleeping space requirement. Intended for retrofit applica- Series detectors.Pack of 10. tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable Agency Listings and Approvals sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the The listings and approvals below apply to intelligent bases as noted. NFPA 72 sleeping space requirement. Intended for retrofit applica- In some cases,certain modules or applications may not be listed by tions. certain approval agencies,or listing may be in process.Consult fac- tory for latest listing status. MOUNTING KITS AND ACCESSORIES • UL/ULC Listed:S1115 TR300:White,replacement flange for B21 OLP(A),B300(A)-6 bases. . FM Approved TR300-IV: Ivory, replacement flange for B21OLP(A), B300(A)-6-IV • CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213, bases. 7300-1653:0236 RA10OZ(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S.single-gang electrical box. For use with B501(A)and B300(A)- 6. Junction Box Selection Guide Single Double4.0"Sq. Base Models Gang Gang 3.5"Oct. 4.0 Oct. 4.0 Sq. with 3.0" 50 mm 60 mm 70 mm 75 mm mud ring B200S,B200SR, Yes Yes Yes Yes Yes Yes No No No No B200SCOA B501 No No Yes No No I Yes Yes Yes Yes No B21OLP,B300-6 Yes No I Yes IYes IYes I Yes INo INo INo INo B224BI,B224RB Yes IYes IYes IYes IYes I Yes INo INo iNo lNo NOTE.Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. NOTE.Applies to all model variants'A""-BL",'=LF;`-IV';'=WH',and"-WHITE".See Product Line Information for detailed model description. I® BiLlf�lra;E NRi1fAt71Qi QUAILITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER FlashScan®, NOTIFIER®and System Sensor®are regis- 12 Clintonville Road tered trademarks of Honeywell International Inc. �� O Northford,CT 06472 @2018 by Honeywell International Inc. All rights reserved. NOT 1 F 1 E R 203.484.7161 Unauthorized use of this document is strictly prohibited. by H O n eywe I I www.notifier.com Country of Origin:Mexico Page 31 Page 32 dn-60429:b1 4DNR InnovairFlex NOTI FI E R° Intelligent Non-Relay Photoelectric a Duct Smoke Detector by Honeywell Intelligent DevicesKe �V The Notifier InnovairFlex DNR intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelec- tric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. • DNRW duct smoke detector,with its NEMA-4 rating, is listed as a watertight,UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute,tem- peratures of -4 degrees F to 158 degrees F, and a humidity range of 0 to 95 percent(non-condensing.) An improved cover design isolates the sensor head, which Specifications allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sen- Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) sor cover.The Notifier InnovairFlex housing provides a 3/4-inch Width,2.5 in(6.6 cm)Depth conduit knockout and ample space to facilitate easy wiring and Size: (Square)7.75 in (19.7 cm) Length; 9 in(22.9 cm)Width; mounting of a relay module. 2.5 in(6.35 cm)Depth The Notifier InnovairFlex duct smoke detector can be custom- Weight: 1.6 lb(0.73 kg) ized to meet local codes and specifications without additional Operating Temperature Range:-4 degrees F to 158 degrees F wiring.The new InnovairFlex product line is compatible with all (-20 degrees C to 70 degrees C) previous Innovair models,including remote test accessories. Storage Temperature Range:-22 degrees F to 158 degrees F Features (-30 degrees C to 70 degrees C) Operating Humidity Range:0%to 95%relative humidity(non- • Photoelectric,integrated low-flow technology condensing) • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to Air Duct Velocity: 100 to 4,000 ft/min(0.5 to 20.32 m/s) 20.32 m/s) • Versatile mounting options: square or rectangular configura- Accessories tion • Broad ranges for operating temperature (-4F to 158F) and Notifier provides system flexibility with a variety of accessories, humidity(0%to 95%non-condensing) including two remote test stations and different means of visible • Patented sampling tube installs from front or back of the and audible system annunciation.As with our duct smoke detec- detector with no tools required tors,all duct smoke detectors accessories are UL listed. • Cover tamper signal DNR(W)s with a date code of 0013 or higher do not require • Increased wiring space with a newly added 3/4" conduit external 24VDC for remote test applications,when used with a knockout remote-test-capable detector. • Available space within housing to accommodate mounting of ACCESSORY CURRENT LOADS AT 24 VDC a relay module • Easily accessible code wheels on sensor head (sold sepa- Device Standby Alarm rately) • Clear cover for convenient visual inspection RA100Z OmA 12 mA Max • Remote testing capability • Requires com line power only RTS151/ OmA 12mA Max • Accommodates the installation of an addressable relay mod- RTS151 KEY ule, sold separately, (FRM-1 or NC-100R) for applications requiring a Form-C relay. dn-60429:b1•07/13/11—Page 1 of 2 Page 32 Page 33 Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases,certain modules may not be listed by certain approval agencies, or listing may be'in process. Con- sult factory for latest listing status. • UL:S911,S635 • ULC:S911,S635 • CFSM: 3242-0075:0221 Product Line Information NOTE.`A or CDN"suffix indicates ULC listed model. DNR(A)l Intelligent non-relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector(sold separately).NEMA-4. FSP-851 R: Remote test capable addressable low-profile photo- electric smoke detector. FSP-851:Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector for FireWarden series panels. NP-10OR: Remote test capable addressable low-profile photo- electric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNRW) duct detector housing. DST1(A): Metal sampling tube duct width up to 1 ft(0.3m) DST1.5(A):Metal sampling tube duct widths up to 1 ft to 2 ft(0.3 to 0.6 m) DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft(0.6 to 1.2 m) DS 5(A): Metal sampling tube duct widths up to 4 ft to 8 ft(1.2 to 2.4 m) DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m) DH4000E-1:Weatherproof enclosure ETX:Metal exhaust tube duct,width 1 ft(0.3 m) M02-04-00:Test magnet P48-21-00:End cap for metal sampling tubes RA100Z(A):Remote annunciator alarm LED RTS151(A): Remote test station RTS151 KEY(A): Remote test station with key lock Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. ONYX® and NOTIFIERO are registered trademarks and NOTI•FIRE•NETT"is a trademark of Honeywell International Inc. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENSINIBINS A NIANSFACIASINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-60429:bl•07/13/11 Page 33 Page 34 SYSTEM SENSOR® SMOKE Duct Smoke Detector Accessories • a Expand the versatility of the lnnovairFlex'm line of duct • smoke detectors with System Sensor notification and test accessories. Available Accessories Duct smoke detector accessories add functionality to the duct APA151 Piezo Annunciator smoke detection system by allowing quick,convenient inspections at eye level and effective audible and visible notification options.All MHR Mini-Horn,Red System Sensor duct smoke detectors and accessories are UL listed. MHW Mini-Horn,White The APA151 piezo annunciator,which replaces the APA451 with a RA100ZJRA100ZA Remote Annunciator new,improved look,provides an audible alarm signal,a red LED to FITS151 Remote Test Station indicate alarm status,and a green LED to indicate power status.It is RTS151 KEY Remote Test Station with Key intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel,to comply with RTS2 Multi-Signaling Accessory NFPA 90A. AOS Add-On Strobe The MHR and MHW SpectrAlert®Advance mini-horns feature RTS2-AOS Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications.Their red LED provides visual indication of an alarm condition. The RTS151 and RTS151 KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location.For 4-wire detectors,the RTS151 KEY test station features a multi-colored LED that alternates between steady green and red.For 2-wire detectors,the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFlex 4-wire conventional duct smoke detectors.These accessories include a key switch that can be used to select one of two connected sensors to be tested,reset,or both Agency Listings by a push button switch.They also enable sensitivity measurements using the SENS-RDR sensitivity reader(sold separately).The AOS UL (Add-On Strobe)is an optional accessory included with the RTS2- AOS model. FM LISTED APPROVED 7300-1653:021 7300-1653:0211 S2522 303IM01 7135-1653:0196 908MOl Page 34 Page 35 Specifications, Duct Smoke Detector Accessories APA151 Piezo Annunciator RTS1 51 Remote Test Station Voltage Regulated 24 VDC Power Requirements Alarm LED:2.8 to 32 VDC,12 mA max. Operating Voltage 16 to 33 VDC Total Current:105 mA max. Maximum Alarm Current 30 mA Test Switch 10 VA @ 32 VDC Temperature Range 0°C to 49°C(32°F to 120°F) Reset Switch 10 VA @ 32 VDC Relative Humidity 10 to 93%non-condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 60°C(14°F to 140°F) Dimensions 4.6"H x 2.9"W x.45"D Relative Humidity 95%non-condensing o Advance ornsWire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR(Full Wave Dimensions 4.8"H x 2.90"W x 1.4-D Rectified)or Regulated 24 VDC or FWR RTS151 KEY Remote Test Station with Key Sounder Current Draw 22 mA RMS max.at 8 to 17.5 Volts DC Power Requirements Power LED(Green):14 to 35 VDC, 29 mA RMS max.at 16 to 33 Volts DC 12 mA max. Temperature Range 0°C to 49°C(32°F to 120°F) Alarm LED(Red):2.8 to 32 VDC, Humidity Range 10 to 93%non-condensing 12 mA max. Total Current: 105 mA max. Nominal Sounder 3 kHz Frequency Alarm Response Time 40 seconds max. 12 to 18 AWG Temperature Range —10°C to 60°C(14°F to 140°F) Wire Gauge Dimensions 124. to x AWG x 0.45'"D Relative Humidity 95%non-condensing Wire Gauge 14 to 18 AWG RA10OZIRAl OOZ-A Remote Annunciator Voltage Range Conventional System:3.1 to 32 VDC Dimensions 4.6"H x 2.75"W x 1.8"D Intelligent System: 18 to 32 VDCMulti-signaling Maximum Alarm Current 10 mA Voltage 20 to 29 VDC Dimensions 4.6-H x 2.8"W x 1.3"D Power Requirements Standby:3.0 mA max. Trouble:16.0 mA max. Alarm without strobe:30 mA max. Alarm with strobe:55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C(14°F to 140°F) Relative Humidity 95%non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8-W x 5.3"H x 1.6"D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. • , SMOKE RTS151 UL S4011 RTS151 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 G) f**1 • C*� RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AOS SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 (2013 System Sensor. SENSOR Phone:BOO-SENSOR2•Fax:630-377-6495 Productentproducnssub�acttochangngtheltestvesionofthisdatasheet. ® for current product information,including the latest version of this data sheet. www.systemsensor.com HVDS20202.8113 Page 35 r j � h ,r- 1 P- Lai 02 41 r g 54 I� K. h k f1 0 0 r Page 37 UV, UWI R, IR3 Flame Detectors The FSL100 Series of flame detectors from Honeywell delivers robust,fast,and reliable detection of flaming fires in a wide range of applications. The range consists of UV, UV/IR and IR3 flame detectors. With a large field of view it can All utilize sophisticated sensing and signal analysis to detect a range of different types detect fires quickly while also rejecting false alarms. of fire including hydrocarbon The FSL100 may be small and lightweight for and non-hydrocarbon sources. Available in UV, UV/IR nd 31R we easy installation but it is designed to work in tough indoor/outdoor environments, as well have your application covered. as potentially explosive atmospheres. r' Suitable for Many Applications •UV,UVAR and IR3 available •Hydrocarbon and non-hydrocarbon sources e pN •Use in potentially explosive atmospheres r v, •Indoor and outdooroperation •High visibility red or discrete white models available Great Performance { ��aa •Approved to EN54-10 and FM3260 flame ® detector standards _" � •Comprehensive automatic self test r \\\ -Remote manual self test option Fast&Reliable •High speed sensors and microprocessor •Sophisticated analysis algorithms •Continuous health monitoring •False alarm rejection M$'!a Reduced Life Cost i., Pt •Long life elements •Pressure compensation to avoid contamination •2 yea r wa rra nty •Buy with confidence Ease of Installation and Use •Relay and mA outputs as standard •Lightweight GRP housing •PPe-formed knockouts •Optional swivel mounting bracket •Long range test lamp available Page 37 Page 38 FSL100-UV ` • Suitable for indoor applications;for Flame Detector example fume hoods and hydrogen �t storage areas • Effective solution for materials burning with low temperatures, e.g.Sulphur FS.LIQo-uv •Alarms to fires from heavy hydrocarbons (wood, paper, petroleum, etc.), light hydrocarbons Honeywell (methanol, methane, etc.), and hydrogen • Good resistance against the influences of: - Direct and reflected sunlight -Artificial light, such as fluorescent tubes and glass covered halogen lamps ;gin= 4 t�z. d1 Page 38 Page 39 FSL100-UWIR •Analysis of the flame flicker-frequency Flame Detector, for improved false alarm rejection • Dual sensing methodology enables a wide range of hydrocarbon and non-hydrocarbon fires to be effectively detected • Good resistance against the influences of: FSLIOO-UVIR - Direct and reflected sunlight -Artificial light, such as fluorescent tubes Honeywell and glass covered halogen lamps -Arcs and electric discharges (static or from e.g. electric motors) -The radiation from electric welding provided that the electric welding takes place at a distance more than 10 feet from the flame detector(a welding rod contains organic compounds which may produce a small flame) a - Page 39 Page 40 FSL100-IR3 •Analysis of the flame flicker frequency 'Flame Detector for improved false alarm rejection ,�� • Particularly suited to liquid f . hydrocarbon and dirtyfires ' •Affected less by window contamination or smoky fires F6[.100-IR3 • Good resistance against the influences of: Honey"It - Direct and reflected sunlight -Artificial light, such as fluorescent tubes and glass covered halogen Lamps -Arcs and electric discharges (static or from e.g.electric motors) -The radiation from electric welding provided that the electric welding takes place at a distance more than 10 feet from the flame detector(a welding rod contains organic compounds which may produce a small flame) • Especially suitable fires that emit Large amounts of smoke Page 40 Page 41 APPLICATIONS Aircraft hangars ✓ ✓✓ Atriums ✓ ✓✓ Battery storage rooms/data communication ✓ ✓✓ Biogas ✓ ,i✓ Car,bus,tram and train parking ✓ ✓✓ Clean rooms:semi-conductor,pharmaceutical,&hospital operating rooms ✓ ✓✓ CNG filling/refilling for buses(public transportation) ✓✓ ✓✓ Cold storage ✓✓ Diesel engine rooms ✓ ✓✓ Electric power transformers ✓✓ ✓ Engine test cells/rooms ✓ ✓✓ ✓✓ Fume hoods ✓✓ ✓ Gas cabinets ✓ ✓✓ ✓ Gas/Gasoline engine rooms ✓ ✓✓ ✓✓ Heating rooms for chemicals ✓✓ ✓ Indoor chemical,fuel,and solvent storage ✓ ✓✓ ✓ Indoor hydrocarbon storage and processing ✓ ✓ ✓✓ Indoor hydrogen storage and processing ✓✓ ✓✓ Laboratories ✓ ✓✓ ✓ Loading and unloading terminals:truck,rail,&marine ✓✓ ✓✓ Monitoring of machinery ✓ ✓✓ ✓✓ Oil and Gas pipe line and pumping stations ✓ ✓✓. Outdoor chemical,fuel,paint,and solvent storage ✓ ✓✓ Outdoor hydrogen storage and processing ✓✓ Paint spray booths ✓✓ Radio amplifier rooms/Isolators for antennas ✓✓ Recycling and waste processing plants ✓ ✓✓ Suitable ✓ Recommended ✓✓ *Please contact your regional sales representative to discuss your application +r � i c 4 Page 41 Page 42 GENERAL SPECIFICATION SPECIFICATIONS:FSL100 SERIES FLAME DETECTORS FSL100 Flame Detector types FSL100-UV,FSL100-UVIR and FSL100-IR3;Choice of red orwhite housings Range 110 ft/35 m(IR31 25 m/80 ft(UV,UVAR)alarming within 10 seconds to a 1 ft2(0.1 mz)n-heptane fire Cone of vision 90'minimum horizontal and vertical Power 10-28 VDC(12-24 VDC nominal) • Continuous green:normal operation Local LEDs • Continuous yellow:fault • Flashing yellow:Fault and guide to repeat self-test after a self-test failure • Continuous red:alarm Standard available 4-20 mA(stepped,sinking,non-isolated) 0 mA power fault/microprocessor fault Current output 2 mA optical fault 4 mA normal operation >20 mAalarm Relay output: De-energized during normal operation,no alarm,SPDT,30 VDC-2 A,60 W max.Energised during normal operation,no fault, -Alarm relay SPDT,30 VDC-2 A,60 W max. -Fault relay Cable gland&terminals Cable entry M20 clearance.Supplied with gland suitable for cable diameter from 0.2"(5.5mm)to 0.5"(13mm).Terminals suitable for0.5mm (20AWG)to1.5mm (15AWG)wire Startup times <10 sec Alarm response time 8 to 30 sec Alarm output settings Selectable LEDs and relays latching/non-latching;factory setting:latching Automatic&manual Self-Test Automatic SensorTest(built in Self-Test)and manual Self-Test Operating current normal 25 mA at 24 VDC Current in alarm,at 24 VDC t75 mA at 24 VDC Fire control panels using end of line(EOL)and alarm resistors(current increase) Connections to: Devices that operate via relay switched outputs PLCs with 4-20 mA inputs To be adjusted to the fire control panel;free terminals are dedicated to the resistors End of line and alarm resistor Note:the alarm and E0 L resistor must be rated 2 W min.each and the total power dissipation of both alarm and EOL resistor should not exceed 2 W Housing Glass Reinforced Polyester(GRP),Non-incendive.UV resistant,Self-Extinguishing V-0(UL-94) Swivel Mount PA66,UV resistant;Stainless Steel fixings;280 g(0.62 lb) Pressure compensating element PCE(Pressure Compensating Element)avoids moisture build-up in the detector housing due to changes in ambient air-pressure Dimensions 4.9 x 3.15 x 2.25 in(125 x 80 x 57 mm) Weight 1.05 lb(465 g) Ingress protection IP65 Temperature,operating -40'Fto+158°F(-40°Cto+70°C) Temperature,ambient ATEXand FM class 3611 -13'Fto+158'F(-25'C to+70'C) Page 42 Page 43 Honeywell Analytics Gas Detection Honeywell Analytics is able to provide gas detection solutions to meet the requirements of all applications and industries. Contact us in the following ways: HEADQUARTERS Europe,Middle East,Africa Americas Asia Pacific Life Safety Distribution GmbH HoneywellAnalytics Distribution Inc. Honeywell Analytics Asia Pacific Javastrasse 2 405 Barclay Blvd. 7FSangAm ITTower, 8604 Hegnau Lincolnshire,IL60069 434,Worldcupbuk-ro,Mapo-gu, Switzerland USA Seoul03922, Tel:+41(0)44 943 4300 Tel:+1 847 955 8200 Korea Fax:+41(0)44 943 4398 Tollfree:+1 800 538 0363 Tel:+82(0)2 6909 0300 gasdetection@honeywell.com Fax:+1 847 955 8210 Fax:+82(0)2 2025 0328 Customer Service: detectgas@honeywell.com India Tel:+91124 4752700 Tel:00800 333 222 44(Freephone number) China Tel:+86 10 5885 8788 3000 Tel:+41 44 943 4380(Alternative number) analytics.ap@honeywell.com Fax:00800 333 222 55 RAE Systems by Honeywell Middle East Tel:+971 4 450 5800(Fixed Gas Detection) Phone:408.952.8200 Middle East Tel:+971 4 450 5852(Portable Gas Detection) Toll Free:1:888.723.4800 Fax:408.952.8480 TECHNICAL SUPPORT EMEA:HAexpert@honeywell.com US:ha.us.serviceChoneywell.com AP:ha.ap.service@honeywell.com www.honeywelianalytics.com www.raesystems.com Please Note: While every effort has been made to ensure accuracy in this publication,no responsibility can be accepted for errors or omissions.Data may change,as well as legislation,and you are strongly advised to obtain copies of the most recently issued regulations,standards,and guidelines.This publication is not intended to form the basis of a contract. 13475_H_FSL100_DS01155_V2_AMER 11/16 ©2016 Honeywell Analytics Honeywell Page 43 Page 44 �J NOTI FI E R° by Honeywell FCO-951 Series Advanced Multi-Criteria Fire/CO Detector General Description The IntelliQuad@ PLUS FCO-951/-IV and FCO-951A/-IV advanced multi-criteria fire/CO detector is a plug-in, addressable device that provides both fire and carbon monoxide(CO)detection.The detec- tor combines four separate sensing elements in one unit to sense multiple components of a fire:smoke,CO,Iighttflame,and heat.This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulates. For CO, the detector's electro- chemical sensing cell creates a separate signal for life safety CO detection. Multiple sensors and communication can greatly reduce nuisance alarms compared to single sensing methods. Sophisticated algo- rithms maximize the advantages of the sensor types creating our - best detection strategy offering heightened immunity to nuisance particulate and enhanced sensitivity to real fire. • Photoelectric sensors detect airborne particles associated with ®- ----- smoke. FCO-951 Multi-Criteria Fire/CO Detector • Thermal sensors detect heat and rate-of-rise (135"F fixed tem- installed in B20OS-WH sounder base perature threshold). • Carbon Monoxide sensors detect this by-product of fire for accu- • Separate audible signal for fire or CO alarm when used with a rate fire detection. B200S series base(13200SCOA series in Canada) • Infrared sensors discern light patterns in the environment as an • 10-year CO cell with end-of-life warning additional data point for alarm determination. • New modern profile This ability to reject certain nuisance alarm triggers,such as theater . Expanded color options smoke,supports the use of the IntelliQuad PLUS Series detector in applications where moderate to heavy nuisance conditions exist that Specifications might cause single sensing detectors to false alarm. The IntelliQuad PLUS Series detector meets both UL 268 7th edition PHYSICAL and UL 521 listing requirements for fire detection as well as the UL • Height:2.7"(69 mm)installed in B200S series sounder base 2075 standard for system-connected life safety carbon monoxide • Diameter: 6.875" (175 mm) installed in B200S series sounder detection. Canadian models meet listing requirements of CAN/ULC base S529,CAN/ULC S530 and CSA 6.19-01. • Weight:3.4 oz.(95 g) Released through the incomplete burning of various fuels, CO is a . Color:White(-IV models are ivory) colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. Because the potential exists for dan- Operating Humidity Range: 15%to 90%Relative Humidity, Non- gerous levels of CO to accumulate in almost any building,legislation condensing mandating the use of CO detection in commercial spaces continues • Operating Temperature Range:320F to 100°F(0°C to 38"C) to grow. • Air Velocity:0 to 4000 ft./min.(0 to 1219.2 m/min.) B200S series intelligent sounder bases (13200SCOA series in Can- ELECTRICAL SPECIFICATIONS ada) are recommended for use with FCO-951 Series IntelliQuad PLUS.These bases can generate either a Temp 3 pattern for fire or • Operating Voltage Range: 15 to 32 VDC a Temp 4 pattern for CO alarm indication. The B200S/B200SCOA • Operating Current @ 24 VDC:200 uA(one communication every series bases recognize the System Sensor synchronization proto- 5 seconds with green LED blink on communication) col, for use as a component of the general evacuation signal — . Maximum Alarm Current: 2 mA @ 24 VDC (one communication along with other System Sensor horns,horn strobes,and chimes— every 5 seconds with red LED solid on) when,connected to a power supply or Fire Alarm Control Panel (FACP)output capable of generating the System Sensor synchroni- Maximum Current:4.5 mA C 24 VDC(one communication every s zation pulses. 5 seconds with amber LED solid on) • Isolator Load Rating:0.0063 Features CO MONITORING UL STANDARD REFERENCE • Unique ability to detect all four major elements of a fire Alarm thresholds are as follows: • Separate CO detection signal • Parts Per Million Detector Response Time Highest nuisance alarm immunity • Automatic drift compensation for smoke and CO sensors 70 t 5ppm 60—240 min. • Uses only one address on the SLC 150 t 5ppm 10—50 min. • RealTest®CO testing capability 400 t 10ppm 4—15 min. • UL 268 7th edition,UL 521,and UL 2075 listed;CAN/ULC S529, CAN/ULC S530 and CSA 6.19-01 listed Page 44 DN-61097:A•4/24/2019—Page 1 of 2 Page 45 Standards TR300:Trim ring,white Per UL standard 2075,the FCO-951 Series has been tested to the TR300-IV:Trim ring,ivory sensitivity limits defined in UL Standard 2034. CK300-IR: IR color kit(includes cover and trim ring),white,10-pack UL Standard: UL 268 7th Edition CK300-IR-IV: IR color kit (includes cover and trim ring), ivory, 10- ULC Standard:CAN/ULC S529 pack CK300-IR-BL: IR color kit(includes cover and trim ring), black, 10- Agency Listings and Approvals pack.Note:Not for use in Canadian CO applications The listings and approvals below apply to the FCO-951 Series. In RA100Z(A):Remote LED annunciator some cases, certain modules may not be listed by certain approval M02-04-00:Detector test magnet agencies,or listing may be in process.Consult the factory for the lat- est listing status. M02-09-00:Telescoping test magnet UUULC:S1111 ACCESSORIES CSFM:7272-0028:0510 Ordering Information FCO 951; Advanced multi-criteria fire/CO detector, FlashScan, I white,UL listed. For ivory,order FCO-951-IV. FCO-951A: Advanced multi-criteria fire/CO detector, FlashScan, white,ULC listed. For ivory,order FCO-951A-IV. BASES Note:Canadian CO applications require base B200SCOA-WI--IV. RA100Z(A) B501-WHITE:4"Mounting base,white Remote LED Annunciator B501-WHITE-BP:4"mounting base,white, 10-pack B501-IV:4"Mounting base,ivory B501-BL:4"Mounting base,black B300-6:6"Flanged mounting base,white B300-6-BP:6"Flanged mounting base,white, 10-pack B300-6-IV:6"Flanged mounting base,ivory - r B20OS-WH:Intelligent addressable sounder base,white CK300-IR-BL TR300 B20OS-IV: Intelligent addressable sounder base,ivory Color Kit Trim Ring B200SCOA-WH: Intelligent addressable sounder base for Canadian CO applications,white, ULC-listed B200SCOA-IV: Intelligent addressable sounder base for Canadian CO applications,ivory, ULC-listed B20OS-LF-WH: Intelligent addressable sounder base, low-fre- quency,white,UL-listed B20OS-LF-IV: Intelligent addressable sounder base, low-frequency, ivory,UL-listed B224BI-WH: Isolator base,white B224BI-IV: Isolator base,ivory B224RB-WH: Relay base,white B224RB-IV: Relay base,ivory ACCESSORIES SMB600:Surface mounting kit(flanged) I® SiR111IMMS a 1111IPIIIN T11Ii QNA11TT SYSTEMS This document Is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice, NOTIFIER FlashScaA NOTIFlER&,Inteili0uaft and Rearrest&are registered trademarks of Honeywell International Inc. 12 Clintonville Road @2019 by Honeywell International Inc.AN rights reserved.Unauthorized Northford,CT 06472 use of this document is strictly prokbited, �J NOT 1 F 1 E R 203.484.7161 www.notifier.com Country of Origin:Mexico by Honeywell Page 45 Page 46 �J NOTI FI E R° 0 by Honeywell (F�SCQ-95f (A) Addressable Carbon Monoxide Detectors General FSCO-951 and FCO-951 A are intelligent, addressable carbon monoxide (CO) detectors with integral communication to provide « � point location for alarm communication and selective maintenance. These detectors have point ID capability that enables each detec- tor address to be set with rotary address switches providing exact device locations.The modern design and expanded color options support contemporary aesthetic demands. In addition,each detec- tor is constructed for exceptional installation and maintenance effi- ciency. The FSCO-951 incorporates carbon monoxide(CO)detection prin- ciples meeting the UL 2075 standard for system-connected life safety carbon monoxide detection. FSCO-951A meets Canadian ° standard CAN/ULC-S588. As an addressable detector, additional \ jl modules are not needed for point ID which streamlines the installa- tion process.This allows you to upgrade your addressable fire sys- tem to meet new CO code requirements in applications with fuel 1 burning equipment such as furnace areas and laundry rooms. Released through the incomplete burning of various fuels, CO is a FSCO-951 installed in B200S WH sounder base colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. Because the potential exists for dangerous levels of CO to accumulate in almost any building, leg- islation mandating the use of CO detection in commercial spaces ELECTRICAL SPECIFICATIONS continues to grow. Operating Voltage Range: 15 to 32 VDC FSCO-951 is recommended for use in conjunction with B200S Operating Current @ 24 VDC: 200 uA (one communication every series intelligent sounder bases. For Canadian applications, use 5 seconds with green LED blink on communication) B200SCOA series with FSCO-951A.These bases can generate a Maximum Alarm Current: 2 mA @ 24 VDC (one communication Temp 4 pattern for CO alarm indication. They recognize the Sys- every 5 seconds with red LED solid on) tem Sensor synchronization protocol. Maximum Current: 4.5 mA @ 24 VDC(one communication every Features and Benefits 5 seconds with amber LED solid on) • Intelligent CO detector Isolator Load Rating: 0.0063 • Automatic drift compensation of CO cell SYSTEM COMPATIBILITY • RealTest@ CO testing capability Communication Protocol: FlashScan@ • UL 2075 listed NFS2-3030: Firmware v27.0 or higher • Canadian standards CAN/ULC-S588 NFS2-640,NFS-320: Firmware v27.01 or higher • Audible signal for CO alarm when used with a B200S/B200SCOA series base CO MONITORING UL STANDARD REFERENCE: • 10-year CO cell with end-of-life warning and fault ALARM THRESHOLDS • New modern profile Parts Per Million Detector Response Time • Expanded color options 70 t 5ppm 60—240 min. Detector Specifications 150 t 5ppm 10—50 min. 400 t 10ppm 4—15 min. PHYSICAL SPECIFICATIONS Per UL standard 2075,the FSCO-951(A)has been tested to the sensi- Height: 2.7 in.(69 mm)installed in B200S series sounder base tivity limits defined in UL 2034/CSA 6.19-01. Diameter: 6.875 in. (175 mm) installed in B200S series sounder bases Weight: 3.4 oz.(95 g) Color: White Operating Humidity Range: 15%to 90% Relative Humidity, Non- condensing Operating Temperature Range: 32°F to 122°F(0°C to 50oC) Page 46 DN-62018:A•1/30/2020—Page 1 of 2 Page 47 Product Line Information Agency Listings and Approvals CO DETECTORS These listings and approvals apply to the FSCO-951 series. In FSCO-951: Intelligent addressable carbon monoxide detector, some cases, certain modules or applications may not be listed by white,UL listed certain approval agencies, or listing may be in process. Consult factory for latest listing status. FSCO-951A: Intelligent addressable carbon monoxide detector, white,ULC listed UL:S1115(FSCO-951) BASES ULC:S1115(FSCO-951A) B501-WHITE: 4"Mounting base,white,UUULC-listed CSFM:5278-0028:0511 (FSCO-951) B501-WHITE-BP: 4" Mounting base, white, UUULC-listed, bulk- pack 10 B501-BL: 4"Mounting base,black,UUULC-listed B501-IV: 4"Mounting base,ivory,UUULC-listed B300-6: 6"Flanged mounting base,UL-listed,white B300-6-BP: 6"Flanged mounting base, UL-listed, white, bulk-pack 10 B300-6-IV: 6"Flanged mounting base,UL-listed,ivory B20OS-WH: Intelligent sounder base,white,UL-listed B20OS-IV: Intelligent sounder base,ivory,UL-listed B200SCOA-WH: Intelligent sounder base for CO applications, white,ULC-listed B200SCOA-IV: Intelligent sounder base for CO applications, ivory, ULC-listed B20OS-LF-WH: Intelligent sounder base,low-frequency,white, UL-listed B20OS-LF-IV: Intelligent sounder base,low-frequency,ivory, UL-listed B224BI-WH: Intelligent isolator base,white,UL-listed B224BI-IV: Intelligent isolator base,ivory,UL-listed B224RB-WH: Intelligent relay base,white,UL-listed B224RB-IV: Intelligent relay base,ivory,UL-listed ACCESSORIES SMB600: Surface Mounting Kit(flanged),ivory TR300: Trim ring,white TR3004V: Trim ring,ivory CK300-CO: CO Color Kit(includes cover and trim ring),white CK300-CO-IV: CO Color Kit(includes cover and trim ring),ivory CK300-CO-BL: CO Color Kit(includes cover and trim ring),black RA100Z: Remote LED annunciator,UL-listed RA100ZA: Remote LED annunciator,ULC-listed M02-04-00: Detector test magnet M02-09-00: Telescoping test magnet 'S® 661r®If6 E NNIIfAC1Ori aUAE1TT SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up4odate and accurate. We cannot cover all specific applications or anticipate all requirements. All specilications are subject to change without notice. NOTIFIER FlashScan, Nobler@+, and RealTest®are registered trademarks of Honeywell Intemational Inc. 12 Clintonville Road @2020 by Honeywell Intemational Inc.All rights reserved.Unauthorized Northford,CT 06472 use of this document isshi*pmhibiled. �� NOT 1 F 1 .E R 203.484.7161 by Honeywell WWW.rlOtifler.COfil Country of Origin:Mexico Page 47 Page 48 DN-60054:1•H-320 Intelligent Bases 94 N OTI F 1 E R° Standard, Relay, Isolator, Sounder, and Low-Frequency Sounder Bases by Honeywell DevicesIntel ligent/Addressable General 1, Intelligent FlashScan@ and CLIP mounting bases and kits provide a variety of ways to install NOTIFIER detectors in any - application. Intelligent detectors can be mounted in either ° flanged or flangeless bases depending on junction box selec- tion (see Junction Box Selection Guide).Across this product line, detectors plug in easily to the base with SEMS screws; Flangeless Mounting Base Flanged Mounting Base and models employ various 12 to 24 AWG wire ranges. B501(A) B210LP(A) Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form-C aV contact relay for control of auxiliary functions such as door V_ closure and elevator recall.Isolator bases allow loops to con- tinue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are avail- { able in temporal and non-temporal pattern versions depend- ing on whether the signal is to be used for evacuation Relay Base purposes.Low frequency sounder bases are UL listed for low Sounder Base Y frequency operation and comply with NFPA 72 requirements B200S(A),B200SR(A), B224RB(A) for sleeping spaces. 9200SCOA This datasheet discusses the following bases: B501(A), 1 Bt 200S.(A), B200S-LF, B200SR(A), B200SR-LF, 1321OLP(A), B2241BI(A), B224RB(A), 13200SCOA, mounting kits, and accessories. Specifications Low-Frequency Sounder Base Diameter: B200S-LF,B200SR-LF • B501:4.1"(104 mm). • B224BI,B224RB,B210LP:6.1"(155 mm). Electrical Ratings • B200S B200S-LF, 13200SR, B200SR-LF, B200SCOA: FOR 6200S; B200S-LF, B200SR, B200SR-LF, 6.875"(17.46 cm). Wire gauge: B200SCOA: • 1322413I,B224RB: 14 to 24 AWG. External supply voltage: 16 to 33 VDC(VFWR) • B210LP, B501, 13200S, B200S-LF, 13200SR, B200SR-LF, Standby current: B200SCOA: 12 to 24 AWG • B200S:500 pA maximum. Temperature range: • B200S-LF,550 pA maximum. • 1322413I, 132241113, 13200S, B200S-LF, 13200SR, 13200SR- • B200SR:500 pA maximum. LF,B200SCOA:32°F to 120°F(0°C to 49°C). • B200SR-LF: 1 mA maximum. • B210LP,B501:-4°F to 150°F(-20°C to 66°C). Alarm current: Humidity range: 10%to 93%RH,non-condensing. 9 B200S:35 mA maximum at high-volume setting; System temperature and humidity ranges: This system 15 mA maximum at low-volume setting. meets NFPA requirements for operation at 0°C to 49°C(32°F • B200S-LF,High-volume setting: to 120°F);and at a relative humidity(noncondensing)of 85% -70 mA maximum @ 33.0 VDC. at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F±1.1°F)per ULC.However,the useful life of the sys- -90 mA maximum @ 24.0 VDC. tem's standby batteries and the electronic components may -140 mA maximum @16.0 VDC. be adversely affected by extreme temperature ranges and B200S-LF,Low-volume setting: humidity.Therefore, it is recommended that this system and -15 mA maximum @ 33.0 VDC. all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C(60°F to 80°F). -20 mA maximum @ 24.0 VDC. -25 mA maximum @ 16.0 VDC. • B200SR:35 mA maximum. • B200SR-LF: -65 mA maximum @ 33.0 VDC. DN-60054:1•213/2015-Page 1 of 4 Page 48 Page 49 —90 mA maximum @ 24.0 VDC. B224RB:Relay base. —125 mA maximum @16.0 VDC. B224RBA: Relay base, ULC Listed. • B200SCOA:40mA Max. (DC),70mA Max.(FWR) B224BI: Isolator base. SLC operating voltage: 15 to 32 VDC. 6224BIA: Isolator base,ULC Listed. SLC standby current:See applicable sensor specification. Sound output: MOUNTING KITS AND ACCESSORIES • (B200S/B200S-LF, high-volume*: Greater than 85 dBA SMB600:Surface mounting kit,flanged. minimum. F110: Retrofit flange for converting high-profile bases to low- • B200S/B200S-LF,low-volume*:Greater than 75 dBA mini- profile. mum. F110BP:Bulk pack of F110(10). • B200SR*/B200SR-LF*:Greater than-85 dBA minimum. F210: Accessory flange ring for B210LP(A) base (new • B200SCOA, high-volume**: Greater than 87 dBA mini- design).6-inch diameter. mum. F2101313:Bulk pack of F210(10). • B200SCOA,low-volume**:Greater than 85 dBA minimum RA10OZ• Remote LED annunciator. •Measured in a UL reverberant room at 10 feet,24 Volts(continuous tone) Measured in a ULC anechoic room at 10 feet 24 Volts continuous tone) RA10OZA: Remote LED annunciator,ULC Listed. FOR B224RB,B224BI: M02-04-00:Detector test magnet. Operating voltage: 15 to 32 VDC(powered by SLC). M02-09-00:Test magnet with telescoping handle. Standby ratings:<500 NA maximum @ 24 VDC. XR2B: Detector removal tool for current heads(T55-127-010 Set time (B224RB only): short delay 55 to 90 msec; long included). delay 6 to 9 seconds. XR2: Detector Remove Tool for use with low profile detector Reset time(13224RB only):20 msec maximum. heads,and FSL-751. Relay characteristics (B224RB only): two-coil latching XP-4: Extension pole for XR2/B(5 to 15 ft/1.524 to 4.572 m). relay; one Form-C contact; ratings (UUCSA): 0.9 A @ 125 T55-127-010: Detector removal head. VAC,0.9 A @ 110 VDC,and 3.0 A @ 30 VDC. BCK-20OB: Black detector kit, package of 10 (for use with Product Line Information photo and ion detectors). WCK-20OB: White detector kit, package of 10 (for use with INTELLIGENT BASES photo and ion detectors). B501:Flangeless mounting base. B501A: Flangeless mounting base, ULC Listed. Agency Listings and Approvals B501 BP:Bulk pack of B501 (10). The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may B21OLP:Flanged mounting base. not be listed by certain approval agencies, or listing.may be B21OLPA: Flanged mounting base,ULC listed in process.Consult factory for latest listing status. B210LPBP:Bulk pack of B210LP(10). • UL Listed:S911,S1115. B200S.Intelligent addressable sounder base capable of pro- • ULC Listed:S911,S1115. ducing sound output in high or low volume with ANSI Tempo- • FM Approved. ral 3,ANSI Temporal 4,continuous tone, marching tone,and • MEA:22-95-E,205-94-E Vol.2;257-06-E custom tone. Uses FlashScan protocol.Only compatible with . CSFM: 7300-1653:0126, 7135-1653:0213, 7300- the NFS-320, NFS2-640 and NFS2-3030 operating version 1653:0109 with version 15.0 or higher panel firmware. B200SA:ULC-listed version of B200S. B200SCOA: ULC-listed version of B200S with CO detector markings in English/French (required in Canada for ULC applications with FCO-851A). B20OS-LF:Low Frequency version of the B200S;produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent;designed to meet the NFPA 72 sleep- ing space requirement. B200SR: Intelligent sounder base capable of producing sound output with ANSI.Temporal 3 or continuous tone. B200SRA: ULC-listed version of B200SR. B200SR-LF: Low Frequency version of the B200SR; pro- duces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent;designed to meet the NFPA 72 sleeping space requirement. Page 2 of 4—DN-60054:I.2/3/2015 Page 49 Page 50 Junction Box Selection Guide Single 4.0"Sq. Base Models Gang 3.5"Oct. 4.0"Oct. 4.0"Sq. with 3.0" 50 mm 60 mm 70 mm 75 mm mud ring B200S,B200S-LF, B200SR,B200SR-LF, Yes Yes Yes Yes Yes No No No No B200SCOA B501 No Yes No No Yes Yes Yes Yes No B21OLP Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224BI No Yes Yes Yes No No No Yes Yes NOTE.Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. DN-60054:1.2/3/2015—Page 3 of 4 Page 50 Page 51 FlashScan®,NOTIFIER®and System Sensor(D are registered trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. M1111*311111 i IVINFABTINN6 All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifies Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60054:I•2/3/2015 Page 51 Page 52 DN-6720:C•H-220 (FMM.1" A),(FM( _. 1 11(A), �J N OT I F'I E R° FZM-1 (A) & FDM-1 (A) Monitor Modules with FlashScan@ by Honeywell Intelligent/Addressable Devices General Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications.Monitor mod- _ ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors(FZM-1(A)). © .� FMM-1(A)is a standard-sized module(typically mounts to a 4' .� •. [10.16 cm]square box)that supervises either a Style D(Class •«< A) or Style B(Class B)circuit of dry-contact input devices. FMM-101(A)is a miniature monitor module a mere 1.3"(3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super- w°"° •«�•�^•�•^-••�•^ vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A)to be mounted in a single-gang box behind the device it monitors. FZM-1(A)is a standard-sized module that monitors and super- • vises compatible two-wire,24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. FDM-1(A)is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class FMM-1(A)(Type H) B)dry-contact initiating device circuits(IDCs)at two separate, consecutive addresses in intelligent,two-wire systems. FlashScanO(U.S. Patent 5,539,389) is a communication pro- A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor tocol developed by NOTIFIER that greatly increases the speed (provided) terminates the Style B circuit. No resistor is of communication between analog intelligent devices. Intelli- required for supervision of the Style D circuit. gent devices communicate in a grouped fashion. If one of the FMM-1(A) OPERATION devices within the group has new information,the panel CPU stops the group poll and concentrates on single points. The Each FMM-1(A) uses one of the available module addresses net effect is response speed greater than five times that of on an SLC loop. It responds to regular polls from the control other designs. panel and reports its type and the status(open/normal/short) of its Initiating Device Circuit(IDC). A flashing LED indicates FMM-1(A) Monitor Module that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- • Built-in type identification automatically identifies this device tions on the loop). as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power FMM-1(A) SPECIFICATIONS required. Nominal operating voltage: 15 to 32 VDC. • High noise(EMF/RFI)immunity. Maximum current draw:5.0 mA(LED on). • SEMS screws with clamping plates for ease of wiring. Average operating current: 350 pA (LED flashing), 1 com- • Direct-dial entry of address:01 —159 on FlashScan loops; munication every 5 seconds,47k EOL. 01 —99 on CLIP loops. Maximum IDC wiring resistance:40 ohms. • LED flashes green during normal operation (this is a pro- EOL resistance:47K ohms. grammable option) and latches on steady red to indicate alarm. Temperature range:320F to 120°F(0°C to 49°C). The FMM-1(A) Monitor Module is intended for use in Intelli- Humidity range: 10%to 93%noncondensing. gent, two-wire systems, where the individual address of each Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x module is selected using the built-in rotary switches. It pro- 1.25" (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x vides either a two-wire or four-wire fault-tolerant Initiating 2 125"(5.398 cm)deep box. Device Circuit(IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED Indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class DN-6720:C•10/06/2010—Page 1 of 4 Page 52 Page 53 ,FMM 01 1(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x • Built-in type identification automatically identifies this device 0.65"(1.651 cm)deep. as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. • Powered directly by two-wire SLC loop.No additional power required. FZM-1(A) Interface Module • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 —159 on FlashScan loops; source. 01 —99 on CLIP loops. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 3 1415 0 1 ADDRESS 0 1 • Direct-dial entry of address: 01 —159 on FlashScan loops, 13 2 2 01 —99 on CLIP loops. 3 12 O 3 LOOP O 3 LED flashes during normal operation;this is a programma- 11 4 4 ble option. 10 9 6 5 s 6 5 • LED latches steady to indicate alarm on command from 8 7 8 7 TENS ONES control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- Y wire conventional smoke detectors.It transmits the status(nor- W U mal,open,or alarm)of one full zone of conventional detectors } m back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS The FMM-101(A) Mini Monitor Module can be installed in.a Use the F2M-1(A)to monitor a zone of two-wire smoke detec- single-gang junction directly behind the monitored unit. Its tors.The monitored circuit may be wired as an NFPA Style B small size and light weight allow it to be installed without rigid (Class B)or Style D(Class A)Initiating Device Circuit.A 3.9 K mounting. The FMM-101(A) is intended for use in intelligent, ohm End-of-Line Resistor(provided)terminates the end of the two-wire systems where the individual address of each module Style B or D (class B or A) circuit(maximum IDC loop resis- is selected using rotary switches. It provides a two-wire initiat- tance is 25 ohms). Install ELR across terminals 8 and 9 for ing device circuit for normally-open-contact fire alarm and Style D application. security devices. The FMM-101(A) can be used to replace MMX-101(A)modules in existing systems. FZM-1(A)OPERATION FMM-101(A)APPLICATIONS Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control Use to monitor a single device or a zone of four-wire smoke panel and reports its type and the status (open/normal/short) detectors,manual fire alarm pull stations,waterflow devices,or of its Initiating Device Circuit(IDC). A flashing LED indicates other normally-open dry-contact devices. May also be used to that the module is in communication with the control panel. monitor normally-open supervisory devices with special super- The LED latches steady on alarm (subject to current limita- visory indication at the control panel. Monitored circuit/device tions on the loop). is wired as an NFPA Style B(Class B)Initiating Device Circuit. A 47K ohm End-of-Line Resistor(provided)terminates the cir- FZM-1(A)SPECIFICATIONS cuit. Nominal operating voltage: 15 to 32 VDC. FMM-101(A)OPERATION Maximum current draw:5.1 mA(LED on). Each FMM-101(A) uses one of the available module Maximum IDC wiring resistance:25 ohms. addresses on an SLC loop. It responds to regular polls from Average operating current: 300 NA, 1 communication and 1 the control panel and reports its type and the status(open/nor- LED flash every 5 seconds,3.9k eol. mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K ohms. FMM-101(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): Nominal operating voltage: 15 to 32 VDC. DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms Average operating current: 350 NA, 1 communication every maximum.Current:90 mA per module maximum. 5 seconds', 47k EOL; 600 pA Max. (Communicating, IDC Temperature range:320F to 120°F(0°C to 49°C). Shorted). . Humidity range: 10%to 93%noncondensing. Maximum IDC wiring resistance:40 ohms. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Voltage: 11 Volts. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Maximum IDC Current:400 NA. 2.125"(5.398 cm)deep box. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 491C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6720:C•10/06/2010 Page 53 Page 54 FDM1(A) Dual Monitor Module -161.002/23/3(AFP-200:FMM-1/-101,FZM-1) The FDM-1(A)Dual Monitor Module is intended for use in intelli- —161.002/42/1 (NFS-640.FMM-1/--101) gent, two-wire systems. It provides two independent two-wire Lloyd's Register: initiating device circuits (IDCs) at two separate, consecutive —03/60011/EI (FMM-1/-101,FZM-1) addresses. It is capable of monitoring normally open contact fire —94/60004/E2(AFP-200.except FDM-1) alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel,- —02/60007(NFS-640:FDM-1) controlled LED. FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 NOTE:The FDM-1(A)provides two Style B(Class B)IDC circuits (NFS2-3030) ONLY. Style D(Class A)IDC circuits are NOT supported in any application. Product Line Information FDM-1(A)SPECIFICATIONS NOTE:'A"suffix indicates ULC-listed model. Normal operating voltage range: 15 to 32 VDC. FMM-1(A):Monitor module. Maximum current draw:6.4 mA(LED on). FMM-101(A): Monitor module,miniature. Average operating current:750 pA(LED flashing). FZM-1(A):Monitor module,two-wire detectors. Maximum IDC wiring resistance: 1,500 ohms. FDM-1(A):Monitor module,dual,two independent Class B cir- Maximum IDC Voltage: 11 Volts. cuits. Maximum IDC Current:240 pA SMB500:Optional surface-mount backbox. EOL resistance:47K ohms. NOTE: See installation instructions and refer,to the SLC Wiring Manual,PN 51253. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(00 to 490C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A)automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then.it will automatically assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the FDM-1(A)are 0,2,4,6,or only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and,FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box.They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations.These modules are intended for power-limited wiring only. The FMM-101(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes,ordinances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC:S635 • FM Approved • CSFM:7300-0028:0219 • MEA:457-99-E • U.S.Coast Guard: DN-6720:C•10/06/2010—Page 3 of 4 Page 54 Page 55 FlashScan®and NOTIFIER®are registered trademarks and FireWatchTm is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 61CINEMINI 11 MANIFACTIMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6720:C•10/06/2010 Page 55 Page 56 DN-6724:133 ,FCM 1(A) & FRM-1 (A) NOT 1 F 1 E R® Series �i� Control and Relay Modules by Honeywell Intelligent Addressable Devices General 'F� CM-1(A)Control Module: The FCM-1(A)Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers,etc.).Addressability allows the FCM-1(A)to be acti- vated, either manually or through panel programming, on a select(zone or area of coverage)basis. L ,FRM 1(A)Relay Module: The FRM-1(A) Addressable Relay I TII E.t PWR�) YL Module provides the system with a dry-contact output for acti- . T,CE„P,,,,,,,,, ,.,n vating a variety of auxiliary devices, such as fans, dampers, control equipment,etc.Addressability allows the dry contact to °°"' be activated, either manually or through panel programming, ,.°,., on a select basis. r TI u, FlashScan®(U.S. Patent 5,539,389) is a communication pro- TO tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points.The net effect is response speed greater than five times that of other designs. FCM-1(A) Features • Built-in type identification automatically identifies these • The FCM-1(A)is configured for a single Class B(Style Y)or devices to the control panel. Class A(Style Z)Notification Appliance Circuit. • Internal circuitry and relay powered directly by two-wire • The FRM-1(A) provides two Form-C dry contacts that SLC loop.The FCM-1(A)module requires power(for horns, switch together. strobes,etc.),or audio(for speakers). • Integral LED "blinks" green each time a communication is Operation received from the control panel and turns on in steady red Each FCM-1(A)or FRM-1(A)uses one of 159 possible module when activated. addresses on a SLC loop (99 on CLIP loops). It responds to • LED blink may be deselected globally(affects all devices). regular polls from the control panel and reports its type and • High noise immunity(EMF/RFI). status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll • audio(up to 70.7 Vrms). received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) • Wide viewing angle of LED. notification or control circuits. • SEMS screws with clamping plates for wiring ease. Upon code command from the panel, the FCM-1(A) will dis- • Direct-dial entry of address 01— 159 for FlashScan loops, connect the supervision and connect the external power sup- 01 —99 for CLIP mode loops. ply in the proper polarity across the load device. The • Speaker, and audible/visual applications may be wired for disconnection,of the supervision provides a positive indication Class B or A(Style Y or Z). to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- Applications munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. The FCM-1(A)is used to switch 24 VDC audible/visual power, Rotary switches set a unique address for each module. The high-level audio (speakers). The FRM-1(A) may be pro- address may be set before or after mounting. The built-in grammed to operate dry contacts for applications such as door TYPE CODE(not settable)will identify the module to the con- holders or Air Handling Unit shutdown, and to reset four-wire trol panel, so as to differentiate between a module and a sen- smoke detector power. sor address. NOTE.Refer to the SLC Manual(PN 51253)for details regarding releasing applications with the FCM-1(A). Refer to the FCM-I-REL Specifications for FCM.1(A) datasheet(DN-60390)for new F/ashScan®releasing applications. Normal operating voltage: 15 to'32 VDC. Construction Maximum current draw: 6.5 mA(LED on). • The face plate is made of off-white heat-resistant plastic. Average operating current: 350 pA direct poll,375 pA group • Controls include two rotary switches for direct-dial entry of poll with LED flashing, 485 pA Max. (LED flashing, NAC address(01-159). shorted.) DN-672403.2/17/2011—Page 1 of 2 Page 56 Page 57 Maximum NAC Line Loss: 4 VDC. Contact Ratings for FRM-1(A) External supply voltage(between Terminals T10 and T11): Maximum (NAC): Regulated 24 VDC; Maximum Current Maximum Load Application (Speakers):70.7 V RMS,50W. Rating Voltage Description Drain on external supply: 1.7 mA maximum using 24 VDC 3 A 30 VDC Resistive Non-Coded supply;2.2 mA Maximum using 80 VRMS supply. 2 A 30 VDC Resistive Coded Max NAC Current Ratings: For class B wiring system, the g A 110 VDC Resistive Non-Coded current rating is 3A; For class A wiring system,the current rat- ing is 2A. .9 A 125 VDC Resistive Non-Coded Temperature range: 32°F to 120°F(0°C to 491C). .5 A 30 VDC Inductive Coded Humidity range: 10%to 93%non-condensing. (UR=5ms) Dimensions: 4.5" 114.3 mm high x 4" 101.6 mm wide x 1 A 30 VDC Inductive Coded 1.25" (31.75 mm)deep. Mount to a 4" (101.6 mm) square x (UR=2ms) 2.125"(53.975 mm)deep box. .3 A 125 VAC Inductive Non-Coded Accessories: SMB500 Electrical Box;CB500 Barrier (PF=0.35) Inductive Specifications for FRM-1(A) 1.5 A 25 VAC (PF=0.35) Non-Coded Normal operating voltage: 15 to 32 VDC. Inductive Maximum current draw: 6.5 mA(LED on). .7 A 70.7 VAC (PF=0.35) Non-Coded Average operating current: 230 pA direct poll;255 pA group poll. Inductive EOL resistance: not used. 2 A 25 VAC (PF=0.35) Non-Coded Temperature range: 320F to 120OF(0°C to 49°C). NOTE:Maximum(Speakers):70.7 V RMS,50 W Humidity range: 10%to 93%non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x Product Line Information 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x NOTE:`A"suffix indicates ULC Listed model. 2.125"(53.975 mm)deep box. FCM-1(A): Intelligent Addressable Control Module. Accessories: SMB500 Electrical Box;CB500 Barrier FRM-1(A): Intelligent Addressable Relay Module. Agency Listings and Approvals A2143-20: Capacitor, required for Class A(Style Z)operation In some cases, certain modules may not be listed by certain of speakers. approval agencies, or listing may be in process. Consult fac- SMB500: Optional Surface-Mount Backbox. tory for latest listing status. CB500: Control Module Barrier-required by UL for separat- • UL:S635 ing power-limited and non-power limited wiring in the same • ULC:S3705(A version only) junction box as FCM-1(A). • FM Approved NOTE:For installation instructions,see the following documents: • CSFM:7300-0028:0219 • FCM-1(A)Installation document 156-1169. • MEA:14-00-E • FRM-1(A)Installation document 156-3502. • FDNY:COA#6067,#6065 • Notifier SLC Wiring Manual,document 51253. Notlfler@ and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot hover all specific applications or anticipate all requirements. MCINEMINC i MANIFACUMNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-6724:133.2/17/2011 Page 57 Page 58 NOT 1 F 1 E R® MR Series January 21,1999 DN-3477•K-100 LO FIRE SYSTEMS Control Relays Section: Miscellaneous GENERAL M EA The Air Products&Controls MR Series Multivoltage Con. �L 73-92-E 73-92-E,Vol.III trol Relays offer SPDT or DPDT 10-amp contacts which ® (MR-101/C or CR,I(MR-201/C or CR, may be operated by one of four input control voltages. A MR-104/C or CR) MR-204/C or CR) single relay may be energized from a voltage source of 24 S3C o VDC,24 VAC,115 VAC,or 230 VAC by wiring to appropri- (MR-101/ or CR,MR-104/C California ate input terminals. or CR, State Fire MR-201/C or CR, it Marshal Each relay contains a red light-emitting diode(LED)which MR-204/C or CR) indicates the relay coil is energized. Relays may be 7300-1004:101 "snapped apart from a standard four-module assembly (MR-101/C,MR-104/C, and used independently. 1 1�� MR-201/C, MR-204/C) These devices are ideal for applications where local con- tacts are required for system status, remote contacts for - .. control of electrical loads and general purpose switching.They are suitable for use with HVAC, Temperature Con- CS733 trot,Fire Alarm,Security,Energy Management,and (MR-104 and Light- ing Control Systems. MR-204 s,4 ,.c '•, ` Series ONLY) 21 The Air Products&Controls MR-199 Heavy Duty Power • _ r Relays are designed for control applications where 30 amp DPDT contacts are required. The 24 VDC and 120 VAC - ON relays are mounted in a rugged steel enclosure. MR SERIES FEATURES (Excluding MR-199 Series) _ • Each relay position-may be energized from one of four _ input control voltages. , s • Each relay position contains a red LED which illuminates •-;_ ���_ �` when the coil is energized. This provides a timesaving = - `' convenience when checking an installed system,no me= tering is required. • Single, dual, or triple relay modules may be "snapped apart"from a standard four-position master. The MR-109/C • SPDT or DPDT relays available. • Available in dust-proof metal enclosures(with gray plastic _ cover on MR-101/C and MR-201/C)with LED viewing port. u O • ' Red enclosure available on some models. • Track mounting hardware to facilitate installation in stan- dard cabinets. - M• UL recognized relays rated at 10,000,000 mechanical operations. The MR-1041C This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or I S 0 9001 anticipate all requirements. All specifications are subject to change without notice. For more information,contact NOTIFIER. Phone:(203)484-7161 FAX:(203)4844118 17111771171 �►� N OTI FI E W 12 Clintonville Road,Northford,Connecticut 06472 ENGINEERING&MANUFACTURING DN-3477.01/21/99—Page 1 of 2 Page 58 Page 59 PRODUCT SPECIFICATIONS FOR PRODUCT LINE INFORMATION MULTIVOLTAGE CONTROL RELAYS Model Description Power requirements: MR-101/T Single SPDT Relay with LED and track- MR-101 Position is rated at 0.015 amps(15 milliamps) mounting hardware(UL recognized). @ 24 VAC,24 VDC, 115 VAC,230 VAC. MR-101/C Single SPDT Relay with LED, mounted in MR-201 Position is rated at 0.035 amps(35 milliamps) metal backbox with plastic cover(UL listed). @ 24 VAC,24 VDC, 115 VAC,230 VAC. MR-101/CR Single SPDT Relay with LED, mounted in Relays: All relays are UL recognized components. NOTE: metal backbox with red plastic cover (UL Only models with enclosures("C"suffix)are UL listed as- listed). semblies(excludes MR-199X-13C and MR-199X-14C). MR-1041T Four-Position SPDT Relay with LEDs and Enclosure: 18 gauge CRS,plated with 1/2"conduit knock- track-mounting hardware(UL recognized). outs(top and bottom). The MR-1011C and MR-2011C in- MR-104/C Four-Position SPDT Relay with LEDs, clude a metal backbox with durable plastic cover. mounted in metal enclosure(UL listed). Contact rating: 10.0 A @ 115 VAC resistive. MRA.04/CR Four-Position SPDT Relay with LEDs, Ambient temperature: -50°Cto+85°C,(-50°Fto+185°F). mounted in a metal backbox with a red Dimensions: cover(UL listed). MR-101/T and MR 2011T are 3.0" (82 mm) H x 2.125" MR 201/T Single DPDT Relay with LED and track- (54 mm)W x 1.5"(38.1 mm)D. mounting hardware (UL recognized). MR-1041T and MR-204/T are 3.0"(82 mm)H x 8.5'(215 MR-201/C Single DPDT Relay with LED, mounted in mm)W x 1.5'(38.1 mm)D. metal backbox with plastic cover(UL listed). MR-1011C and MR-2011C are 6.125" (130.2 mm) H x MR-201/CR Single DPDT Relay with LED, mounted in 3.25"(82 mm)W x 2.5"(63.5 mm)D. metal backbox with red plastic cover(UL MR-1041C and MR-2041C are 6.125"(130.2 mm)H x 9.5' listed). (241.3 mm)W x 2.5"(63.5 mm)D. MR-204/T Four-Position DPDT Relay with LEDs and track-mounting hardware (UL recognized). PRODUCT SPECIFICATIONS MR-204/C Four-Position DPDT Relay with LEDs, FOR HEAVY-DUTY POWER RELAYS mounted in a metal enclosure(UL listed). Contact arrangement: DPDT standard. MR-204/CR Four-Position. DPDT Relay with LEDs, Contact rating 30 Amps @ 240 VAC;20 Amps @ 277 mounted in metal backbox with a red cover (UL listed). VAC;2 HP @ 250 VAC. MR-199X-13 Heavy-duty DPDT Relay only,24 VDC coil Coil power: MR 199X-13 is rated at 24 VDC @ 85 mA. input(UL recognized). MR-199X-14 is rated at 120 VAC @ 85 mA. MR-199X-13C Heavy-duty DPDT Relay, 24 VDC coil in- Temperature range: -30°C to+50°C (-22°F to+122°F).ForMR put,mounted in enclosure(UL recognized). MR-199 -14. -3: C to to*C(-6 (-67°F to+176°F). For MR-199X-14 Heavy-duty DPDT Relay only,120 VAC coil MR-199X-14: -55°C to+45°C(-67°F to+113°F). Dimensions: MR-199X-13 and MR-199X-14 is 3.13"(79.4 input(UL recognized). mm)high x 2.5"(63.5 mm)wide x 2.31"(58.7 mm)deep. MR-199X-14C Heavy-duty DPDT Relay, 120 VAC coil in- MR-199X-13C and MR-199X-14C is 5.31"(134.9 mm)high put,mounted in enclosure(UL recognized). x 3.38"(85.9 mm)wide x 3.13"(96.8 mm)deep. MR SERIES RELAYS COIL VOLTAGE CONTACTS MOUNTING LISTINGS I RED MODEL UL, COVER NUMBER I) . A 12C 230 SPAT DPDT DPDT Track Spacer Enclosure CSFM, ULC . (Add"R" VDC VAC VAC VAC (10A) (10A) (30A) p suffix.) ` 8 MEA MR-101�f X X X X 1 X MR-101/C X X X X 1 X X X MR 104ff X X X X 4 X X ti MR 104/C. X X X X 4 X X X X MR 201/T X X X X 1 X MR 201/C X X X X 1 X X X MR 2041T X X X X 4 X X MR 204/C X X X X 4 X X X X MR-1 99X-1 3 X 1 X MR 199X-13C X 1 X MR-199X-14 EX 1 MR 199X-14C 1 X Page 2 of -DN-3477.01/21/99' Page 59 Page 60 DN-6726:D•H-240 (NBG-12L;O N OTI F 1 E R° Addressable Manual Pull Station by Honeywell Intelligent/Addressable Devices General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable,the control panel can display the exact location of the activated manual station.This leads fire personnel quickly to the location of the . alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station,flashes in normal operation and latches steady - red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop(accepts up to 12 AWG/3.25 mm2 wire). The NBG-12LX • Can be surface mounted (with SB-10 or SB-1/0) or semi- Addressable Manual Pull Station flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4"(10.16 cm)square electrical box. Installation • Smooth dual-action design. The NBG-12LX will mount semi-flush into a single-gang, dou- • Meets ADAAG controls and operating mechanisms guide- ble-gang, or standard 4" (10.16 cm) square electrical outlet lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. box, or will surface mount to the model SB-10 or SB-1/0 sur- maximum activation force. face backbox. If the NBG-12LX is being semi-flush mounted, • Highly visible. then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. • Includes Braille text on station handle. Operation • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch • Meets UL 38, Standard for Manually Actuated Signaling in the down/activated position.Once latched,the word"ACTI- Boxes. VATED" (in bright yellow) appears at the top of the handle, • Up to 99 NBG-12LX stations per loop on CLIP protocol while a portion of the handle protrudes from the bottom of the loops. station.To reset the station,simply unlock the station with the e Up to 159 NBG-12LX stations per loop on FlashScan@ pro- key and pull the door open.This action resets the handle;clos- tocol loops. ing the door automatically resets the switch. • Dual-color LED blinks green to indicate normal on Each manual station, on command from the control panel, FlashScan®systems. sends data to the panel representing the state of the manual switch.Two rotary decimal switches allow address settings Construction (1 —159 on FlashScan®systems, 1 —99 on CLIP systems). Shell, door, and handle are molded of durable polycarbonate Architectural/Engineering material with a textured finish. Specifications Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may.be tested, and so • Shipping Weight:9.6 oz. (272.15 g) designed that after actual Emergency Operation, they cannot • Normal operating voltage:24 VDC. be restored to normal except by use of a key.An operated sta- • Maximum SLC loop voltage:28.0 VDC. tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of • Maximum SLC standby current:375 NA. red-colored polycarbonate material with clearly visible operat- • Maximum SLC alarm current:5 mA. Ing instructions provided on the cover. The word FIRE shall • Temperature Range:32°F to 120°F(0°C to 49°C) appear on the front of the stations in white letters, 1.00 inches • Relative Humidity: 10%to 93%(noncondensing) (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-1/0;or semi-flush • For use indoors in a dry location mounting on a standard single-gang, double-gang, or DN-6726:13•4/13/2012—Page 1 of 2 Page 60 Page 61 4°(10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station.The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station.Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP:Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. 4B-10:Surface backbox;metal. SB-1/0:Surface backbox;plastic. BG12TR:Optional trim ring. 17021:Keys,set of two. NY-Plate:New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E. • CSFM:7150-0028:0199. • FDNY:COA#6085(NFS2-640),COA#6098(NFS2-3030). • BSMI:C1313066760047. • U.S.Coast Guard. • Lloyd's Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENi1NEEI1Ni&NIANOFASTINNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-67260•4/13/2012 Page 61 Page 62 SYSTEM SENSOR® Multi-Voltage Conventional Relays � �_ System Sensor's multi-voltage conventional relays are used forhigh-current switching applications such — �- as fan and damper assembly control,door control, air handling unit controls,and other types of system interfacing. Features The R-10T,R-20T,R-14T,and the R-24T models are multi- -Multi-voltage operation voltage relays with terminal strip field wiring connections,mounting track,and hardware.The R-10T is a single FORM—C(SPDT)relay with •Activation LEDs a red activation LED,and the R-14T is a four-gang 1 FORM—C(SPDT) •Easy and flexible installation relay with four red activation LEDs.The R-20T is a single 2 FORM—C •Reliable and robust design (DPDT)relay with a red activation LED,and the R-24T is a four-gang 2 FORM—C(DPDT)relay with four red activation LEDs. •Multipurpose field installations •Multi-voltage relays with terminal strip field wiring connections, The R-10E/R-20E and R-14E/R-24E are similar to theT-series mounting track,and hardware for R-1 OT/20Tand R-14T/24T track mount relays,but they are mounted into a steel enclosure.The •Removable front cover on steel enclosure for R-10E/R-20E and R- enclosure has a removable front cover that provides easy access and 14/R-24E,which mount inside the enclosure an LED viewing hole on the top of the cover. •LED viewing hole on top of the steel enclosure's cover PR-1/PR-2/PR-3 are epoxy encapsulated multi-voltage relays.They Extra pair of wires for redundant power input on PR-3 are single-pole double-throw relays that use a red LED as a visible Terminal strip field wiring connections,mounting track,and indication of relay coil energization.PR-3 is hardware identical to PR-2,except it has an extra pair of wires for redundant power input. Model EOLR-1 is an epoxy encapsulated,single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems,e.g.to supervise power supplies. Agency Listings � MEA ° R�' approved LISTED Page 62 Page 63 Multi-Voltage Conventional Relay Specifications Specifications:R-10T/R-14T/R-20T/R-24T Specifications:PR-I Operating Voltage 18-35 VDC,18-35 VAC,115 VAC,230 VAC Operating Voltage 18-35 VDC,18-35 VAC,120 VAC Operating Current 20 mA DC max.@ 24VDC,24 VAC,115 VAC, Operating Current 15 mA DC max.@ 24 VDC,24 VAC,120 VAC 230 VAC(R-I OT/R-14T) Operating Temperature -40°F to 158T(-40°C to 70°C) 40 mA DC max.@ 24 VDC,24 VAC,115 VAC, Humidity Range 10-93%RH 230 VAC(R-20T/R-24T) Wire Length 8-minimum Operating Temperature -40°F to 158°F(-40°C to 70°C) Dimensions 0.87"H x 2.01'W x 1.42"D Humidity Range 10%-93%non-condensing Contact Ratings 24VDC:7 A with VR=5 mS Dimensions R-1 OT/R-20T:2.51 x 3.35'W x 1.2"H 120 VAC:7 A max.(0.35 PF) 11-14T/11-24T:101 x 3.35-W x 1.2"H 250 VAC:10 A resistive Contact Ratings 24 VDC:7 A with L/R=5 mS 30 VDC:10 A resistive 120 VAC:10 A 20 VAC:1/6 HP Specifications: � .•1 120 VAC:1 A Operating Voltage 10 to 40 VDC f Operating Current 30 mA DC max. Operating Voltage 18-35 VDC,18-35 VAC,115 VAC,230 VAC Operating Temperature -40°F to 1587(-40°C to 70°C) Operating Current 20 mA DC max.@ 24 VDC,24 VAC,115 VAC, Humidity Range 10-93%RH 230 VAC(R-1 OE/13-14E) Wire Length 8"minimum 40 mA DC max.@ 24VDC,24 VAC,115 VAC, Dimensions 0.91"H x 1.65'W x 1.22 D 230 VAC(R-20E/R-24E) Contact Ratings 120 VAC:10 A max.(resistive load) Operating Temperature -40°F to 158T(-40°C to 70°C) 120 VAC:7 A max.(0.35 PF) Humidity Range 10%-93%non-condensing 250 VAC:10 A max.(resistive load) Dimensions R-10E/R-20E:5.11 x 3.75'W x 2.5H 30 VDC:10 A max.(resistive load) R-1 4E/R-24E:111 x 5.3W x 2.5 HEOLRA Contact Ratings 24 VDC:7 A with UR=5 mS Operating Voltage 9 to 40 VDC 120 VAC:10 A Operating Current 20 mA DC max. 120 VAC:1/6 HP Operating Temperature -227 to 140T(-30°C to 60°C) 230 VAC:7 A Humidity Range 10-93%RH Wire Length 8-minimum Contact Ratings 120 VAC:0.5 A max.(resistive load) 30VDC:3 A max.(resistive load) -{ r PR-1 EOLR-1 PR-3 R-1 OE&R-20E Enclosure r J; A, PR-2 R-10T R-14T R-14E&R-24E Enclosure S ®2007 System Sensor. YSTEM 3825 Ohio Avenue•St.Charles,IL 60174 RoduttspetficatlonssubtetttochangewithoutnoticeVlsi[rystemsenso[comfw SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 arrentpmduttinormauon,17ncluding the latest 2-005-3/07-#17ersionofthis data sheet A05-0372-005.3/OI•n7782 Page 63 Page 64 SYSTEM SENSOR® �r Indoor Selectable- s , Output Horns, Strobes, and -- - - - Horn Strobes for Wall Applications System Sensor L-Series audible visible notification • products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. aa Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and. • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain,FIRE, • Tamper resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,-and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING UL F M 0; LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 AVDS865-05•212 212 01 8•Page 1 Page 64 Page 65 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/e-inch back box,4 x 4 x 1 Y2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 1 7/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the SynceCircuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the SynceCircuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110,135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor SynceCircuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 Page 65 Page 66 UL Current Draw Data UL Max.Strobe Current • • 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC ' DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(rnA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190, 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.11K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data StrobeHorn and Horn Output 8-17.5 16-33 Switch Volts Volts Position Sound Pattem dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9' Coded High 85 90 90 10' 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 Page 66 Page 67 L-Series Dimensions 1.91' 3.46' 3A6" 485 mm 88 mm 1.25' 357° 155' 68 mm 125' 32 mm (9.1 cm) (3A cm) 32 mm 0 0 I!P p 5.27' •1 1• 5.38° 133.9 mm 59° (13.7 cm) O 133.9 mm �1 Ilill O 601 L 11111 o p C A0548-00 A0547-00 A0557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Bok SBBGRL,SBBGWL 4.70' (11.94 cm) 1.91° 4.7° 1.25' 41 (4.85 cm) 119 mm 32 mm (1224 cm) 4.69 cm 115° 11 ( ) (3.18 mm) 0 o ® o di.. . 5.67° 5.67° ;1 5.78" 0a68 em) (14.4 cm) � 144 mm o 1 III�I�I�i 11111�'�1�1 O ® O 0 A0550-00 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Homs* P2RL 2-W(— ire,Horn Strobe,Red HRL* Horn,Red P2WL 2-Wire,Horn Strobe,White HWL* Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBWL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe„Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 02018 System Sensor- Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensoccom SENSOR® www.systemsensor.com y for current product information,including the latest version of this data sheet. temsensor.com AVDS865-05.2/22/2018 Page 67 Page 68 "STEM SENSOR® y Indoor Selectable- �l•, �' Output Strobes and Horn Strobes for Ceiling Applications , . System Sensor L-Series audible visible notification V products are rich with features guaranteed to cut r== ti installation times and maximize profits.with lower current draw and modern aesthetics. �°��. '. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 AVDS868-02.1 2/0 112 01 7•Page 3 Page 68 Page 69 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1 Y2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or fulkwave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11A 6 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y.(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage.Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) InputTerminal Wire Gauge 12 to 18 AWG . Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02.1 210 1/2 01 7•Page 2 Page 69 Page 70 UL Current Draw Data UL Max.Strobe Current Draw(rnA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low, 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn Output 8-17.5 16-33 Switch Volts Volts Position Sound Pattem dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 _ Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 Page 70 Page 71 L-Series Dimensions 2.47'(62.7 mm) 1.37°(34.8 mm) 6.92°diam. 2,5° �( 6.83°diam, (175.77 mm) (64 mm) (173 mm) ••M•rr.rM O 87R O O o Q o O O 0 O O o Q o 0 A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box m 0 0 s �ptWTI ® ® O O O ® d O • • A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red (SCWL-CLR_-ALERT) Strobe,White,ALERT) PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865'Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". SYSTEM ©2017 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensoccom SENSORa Phone:800-SENSOR2•Fax:630-377-6495 for current product information including the latest version of this data sheet. AVDS868-02.12/01/2017 Page 71 Page 72 SYSTEM SENSOR® Outdoor Selectable- Output Horns, Y E Strobes, and Horn Strobes for Wall Applications SPECTRANert SpectrAlert®Advance outdoor audible visible products AL IM v AM M c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X,IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including'indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151*F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from-40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion. Knock-outs located on the back eliminate the need to drill Oholes for screw-in mounting.Plastic and metal weatherproof back U` �ACA boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch F M MEA 7300-1653:187(outdoor strobes) LISTED 7125-1653:188(horn sVobos, knock-outs at the back.A screw-in NPT plug with an O-ring gasket S4011(chimes,horn strobes,horns) APPROVED approved chime S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. Page 72 Page 73 SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuif'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Hom Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40OF to 151 OF(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7-W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7-W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1-W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVOS01201 Page 73 Page 74 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(rnA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 Strobe,UL Max.Current Draw(mA RMS),2-Wire Horn 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with 8-175 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 Page 74 Page 75 SpectrAlert Advance Diagrams o-4.7"-1 2.5" 5.6" ° O 0 I P LJ 1 Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box 0 ®®® Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P214K't 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe„High cd,Red,Outdoor,120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM mt to c System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensorcom SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 AV includingDS01201 forcurreniprotluctlnformadon,DS01201 helatestversionot histlatasheet. •3/12 Page 75 Page 76 INSTALLATION AND MAINTENANCE INSTRUCTIONS SYSTEM 71 o SENSORCD 3525 Ohio Avenue,St.Charles,Illinois 60174 L-Series Back Boxes 800/736-7672,FAX:630/377-6495 www.systemsensor.com GENERAL DESCRIPTION MODEL REFERENCE The L Series surface mount back boxes are designed to fit System Sensor L-series devices. They provide a hard surface mounting option for surfaces Model Description Color such as concrete and brick.Models are available in wall and ceiling mounting SBBRL Wall Surface Mount Back Box,4x4 Horn,Strobes Red formats,red and white color options and by device type see below for specific and Horn Strobes model numbers and descriptions. SBBWL Wall Surface Mount Back Box,4x4 Horn,Strobes White The L series surface mount back boxes include a grounding plate and ground- and Horn Strobes ing screw for electrical grounding and threaded knockout holes for 3/4 inch SBBGRL Wall Surface Mount Back Box,2x4 Horn,Strobes Red conduit adapters.(See Figure 1.) and Horn Strobes SBBGWL Wall Surface Mount Back Box,2x4 Horn,Strobes White INSTALLATION and Horn Strobes Refer to the System Sensor device manual for specific installation and mount- ing instructions. SBBGRL Ceiling Surface Mount Back Box,Horn,Strobes, Red Horn Strobes,Speakers and Speaker Strobes SBBCWL Ceiling Surface Mount Back Box,Horn,Strobes, White Horn Strobes,Speakers and Speaker Strobes SBBSPRL Wall Surface Mount Back Box,Speakers and Red Speaker Strobes SBBSPWL Wall Surface Mount Back Box,Speakers and White Speaker Strobes FIGURE 1.SURFACE MOUNT BACK BOX Grounding screw and Grounding screw and grounding plate grounding plate e e e e cp Grounding screw ® e ® and grounding plate 0 e Knock-outs Knock-outs Knock-outs A0524-00 a Grounding screw and grounding plate ® e A0525-00 Knock-outs System Sensors is a registered trademark of Hon*veg Intemational,Inc. Page 76 I56-5r.09-01 ®2016 System Sensor.0O Page 77 SYSTEM SENSOR® ♦. _ - k Audible Visible Accessories e System Sensor L-Series offers a wide range of Audible Visible (AV)accessories to enable you to meet a variety of application requirements. Features The MP120KL Mounting Plate is designed to use 120 VAC to power MP120KL Mounting Plate SpectrAlert Advance horns,strobes,horn strobes,chimes,and chime strobes. • Designed for both indoor and outdoor use • Plug-in design eliminates ground faults Color Lens Attachments install easily on any L-Series strobe • Power supply that converts 120 VAC to nominal 24 V FWR devices to provide distinctive visual signaling. • Compatible with all two-wire L-Series devices Bezel Kits enable installers to easily turn any L-Series Fire or Plain Color Lens Attachments device into a device that meets ECN/MNS requirements.Bezel kits are available for all varieties and footprints of L-Series products and • Easily turns any device into a strobe for ECS/MNS events: come in FIRE,ALERT,EVAC,AGENT,FUEGO,FOGO,and Plain severe weather,toxic gases,sprinkler activation and more options making customization easy. • Outdoor rated from—351F to 151°F • Wall-or ceiling-mount lenses available Universal Trlm Rings for wall and ceiling mount devices allow for additional space within the backbox. • UL 1638 listed Bezel Kits L-Series Surface Mount Back Boxes are the best solution in locations where you have a hard surface to mount to. • Easily turn a Fire or Plain device into a device to meet ECS/MNS requirements The Sync•Circuit Module synchronizes L-Series strobes at 1 Hz and • Bezel kits available for strobes,horns,chimes,horn strobes, horns and chimes at temporal 3 over a single pair of wires.Patented chime strobes and speaker strobes module technology also allows the silencing of horns or chimes on • Bezels options with FIRE,ALERT,EVAC,AGENT,PLAIN,FUEGO, horn strobe and chime strobe models over a pair of wires.See the FOGO printing Sync•Circuit Datasheet for more information. • For use with L-Series devices only • Operating temperature-40OF to 151OF Agency Listings U` F M 0 LISTED APPROVED 55512 FM approved: 7125-16539504 54011 Sync modules and MP120KL. 7135-1653.0503 S4D48 3057383,3057072,3057493 Does not include color lenses. Page 77 Page 78 Specifications 120 VAC mounting plate model MP120KL shall be listed to UL 464 for fire protective signaling systems.The mounting plate shall power a two- wire L-Series horn,strobe,horn strobe,chime or chime strobe from a 120 VAC supply converted to nominal 24 V FWR.For indoor applications, the mounting plate shall be installed in a 4421/e-inch junction box. Compatibility MP120KL may be used with any of the following products at all horn and strobe settings:P2RL,P2WL,P2RL-P,P2WL-P,P2RL-SP,P2WL-SP, PC2RL,PC2WL,SRL,SWL,SRL-P,SWL-P,SRL-SP,SWL-CLR-ALERT,SWL-ALERT,SCRL,SCWL,SCWL-CLR-ALERT,HRL,HWL,CHRL, CHWL,CHSRL,CHSWL,CHSCRL,CHSCWL. Physical/operating Standard Operating Temperature -40oF to 151°F(-40°C to WC) Humidity Range 10 to 93%non-condensing(indoor products) Nominal Voltage Regulated 120 VAC Operating Voltage Range 96-132 VAC Current Draw From AC Line 150 mA max. L-Series Bezels The System Sensor L-Series bezels are for installation with strobes,horns,chimes,horn strobes,chime strobes,and speaker strobes. Bezels are offered in red and white for both wall and ceiling devices.Available in FIRE,ALERT,EVAC,AGENT,Plain(no marking),FUEGO, and FOGO. Operating temperature shall be-40oF to 151°F. 0p 000p00 0 000p0A00 1 11111 n WS 0 Page 78 Page 79 Specifications Colored Lens Attachments The System Sensor L-Series colored lens attachments shall be approved for fire protective service as listed in UL 1638.The lens attachments shall only be used with plain(no"FIRE"print)System Sensor strobe devices or in conjunction with a non-fire printed bezel.The lens shall mount to any wall-or ceiling-mount strobes and shall be rated from—350F to 151 OF. Colored lens attachments may be used with the following System Sensor L-Series plain(non-FIRE-printed)strobe models:P2RL-P,P2WL-P, SRL-P,SWL-P,SPSRL-P,SPSWL-P,SPSCWL-P,or any device used with a non-FIRE printed bezel. Colored Lens Installation Installation to Wall-Mount Strobe Installation to Ceiling-Mount Strobe 0 0 01010101 111111111 1�1�1�1�1�1�1 Page 79 Page 80 Ordering Information Part No. Description Part No. Description Surface Mount Back Box Colored Lenses SBBRL Red,wall-mount,compatible with standard LENS-132 Wall-mount,blue horns,strobes,horn strobes,chimes and chime LENS-R2 Wall-mount,red strobes LENS-G2 Wall-mount,green SBBWL White,wall-mount,compatible with standard horns,strobes,horn strobes,chimes and chime LENS-A2 Wall-mount,amber strobes LENS-BC2 Ceiling-mount,blue SBBSPRL Red,wall-mount,compatible with speakers and LENS-RC2 Ceiling-mount,red speaker strobes LENS-GC2 Ceiling-mount,green SBBSPWL White,wall-mount,compatible with speakers LENS AC2 Ceiling-mount,amber and speaker strobes SBBCRL Red,ceiling-mount compatible with horns, Retrofit Plates strobe,horn strobes,chimes,chime strobes, (For use with horn strobe&speaker strobe devices) speakers and speaker strobes RFPW 9.5"x 7"white SBBCWL White,ceiling-mount,compatible with horns, RFP 9.5"x 7"red strobe,horn strobes,chimes,chime strobes, Mounting Plate speakers and speaker strobes MP120KL 120 VAC Adapter Mounting Plate SBBGRL Red,wall-mount,compatible with compact horns,strobes,horn strobes Sync Modules SBBGWL White,wall-mount,compatible with , MDL3W White,12/24 volt Sync-Circuit module compact horns,strobes,horn strobes MDL3R Red,12/24 volt Sync-Circuit module Bezels* Trim Rings BZR Wall Red Bezel Kit TR-2 Universal wall trim ring,red,6.3"x 8.2" BZW Wall White Bezel Kit TRC-2 Universal ceiling trim ring,red,diameter 8.5" BZGR Compact Wall Red Bezel Kit TR-2W Universal wall trim ring,white,6.3"x 8.2" BZGW Compact Wall White Bezel Kit TRC-2W Universal ceiling trim ring,white,diameter 8.5" BZRC Horn Strobe Ceiling Red Bezel Kit BZWC Horn Strobe Ceiling White Bezel Kit BZSPR Speaker Wall Red Bezel Kit BZSPW Speaker Wall White Bezel Kit BZSPRC Speaker Ceiling Red Bezel Kit BZSPWC Speaker Ceiling White Bezel Kit *Each bezel pack ships in a package of 5.For desired bezel option add-F(FIRE),-AL(ALERT),-EV(EVAC),-AG(AGENT),-P(Plain), -SP(FUEGO),-PG(FOGO)for desired printing. 3825 Ohio Avenue•St.Charles, IL 60174 SYSTEM m2017 System Sensor. Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensoccom SENSO ® for current product Information,including the latest version of this data sheet. R www.systemsensor.com AVDS87001.03-17 Page 80 Page 81 © KMOX® KNOXBOXO 3200 When seconds matter- The KnoxBox 3200 is the number one high-security key lock box trusted by first responders and property owners. Store up to 10 keys to quickly gain rapid access to commercial properties. FEATURES Stores maximum 10 keys.Access cards and small entry Available In 3 colors: items may also fit in interi compartment but will reduce _ MEN max key quantity. Black Aluminum Dark v Built Knox-Rugged an secure: UL 1037, UL 1610, ce Bronze UL 1332, UL 437 Finished with Kn -Coat®to protect four times better than standard owder coat v Weather-re stant door gasket Hinged oor - BEN FITS -fir z , 1V ows rapid property access Reduces damage Recessed Mount property ams g Prevents forced entry into buildings Minimizes first responder injury 'Surface Mou Compliant to National Fire Code(NFPA, IFC, IBC) WEIGHT- DIMENSIONS: OPTIONS Surface Mount-8 Ibs Surface Mount Bo 4"H x 5"W x 3-7/8" Knox Tamper Alert connects to building's alarm system Recessed Mount-9 Ibs Recessed Mount Fla e-7"H x 7"W for extra security Mount types: Recessed and Surface SURFACE MOUNT-FRONT VIEW 3 color options: Black,Aluminum, Dark Bronze 5- ACCESSORIES Stainless eel Heavy 1/8"thick door hinge Multi-Purpose Switch for use on electrical doors, gates stainless steel lock cover and other electrical equipment © 4" Recess Mounting Kit for new concrete or masonry construction Hole for tamper seal Public Safety Labels �-- 1/2"solid plate Tag-Out Tamper Seals steel door Key Tags with gasket y 1/4"solid steel housing v ey Rings 100%welded OR RING SPECIFICATIONS RECESS MOUNT- RONT VIEW SIDE VIEW To insure rocurement and delivery of the KnoxBox 3200,it 7" DE— { —3"DEEP Is suggests that following specification paragraph is used: 1/4^steel case, KnoxBox surfac recessed mount with hinged door,with/without 100%welded UL Listed Knox Ta per Alert. 1/4"plate steel housing, 1/2" thick steel door with terior gasket seal and stainless steel door hinge. Box and lock U Listed. Lock has 1/8"thick stainless ID steel dust cover with tam er seal mounting capability. 7" © Exterior Dimensions:Surf a a Mount Body-4"H x 5"W x 3-7/8"D "lG" Recessed Mount Flange-7"H 7"W Lock:UL Listed. Double-action ro ting tumblers and hardened steel pins accessed by a biased cu Ely. lange Finish: Knox-Coat proprietary finishi process stcu F (recessed7"x 7"flange V model only) (recessed Color:Black, Dark Bronze or Aluminum L model only) uSM P/N:KnoxBox 3200(mfr's cat. ID) E°°""'EW 3-7/8" Mfr's Name: KNOX COMPANY CE 1601 W. DEER VALLEY RD. PHOENIX,AZ 85027 1 T.80ow5aWU 2 -687-2290 1 INFO@KNOXBOX.COM I KNOXBOX.COM ©Knox Company.All rights reserved. MKT-KBSPEC-0019-E Page 82 © KNOX® KNOXBOXO 3200 When seconds matter'" GENERAL MOUNTING INSTRUCTIONS ATTENTION:KnoxBox is a very strong device that MUST be mounted Suggested minimum mounting height, properly to ensure maximum security and resist physical attack. 6 feet above ground. Inside Vieyv Large 5„ Optional thick ,�` rear Knox steel 7/8" �3-1/4" 7/8" Tamper Alert washer — 3/4" 3/A" Rear Knox Tamper Alert hole Key Hook Holes 7/8 X® 1 0 2-5/16" To —- o X® 4" Door To building alarm system d O tional building hinge p alarm door Knox system Tamper Alert � X o X® Door 3/8"Grade 5 or Alarm wire Grade 8 fastener All mounting Holes marked"x"are holes are 7/16" exit opening Flange-+ �—Solid diameter.For used for mounting with Solid concrete wall concrete mounting use Rear Knox at least 318"Grade 5 or w(I at least 3/8" Tamper Alert Grade 8 fasteners Grade 5 or Grade 8 mounting holes KnoxBox 3200 Hinged KnoxBox 00 Hinged fasteners Door Surface Mount Door Red%Iss Mount RECESS MOUNTING KIT AND INSTALLAN`INSTRUCTIONS The Recess Mounting Kit(RMK) includes shell housing and unting hardware, RECESS MOUNTING which may only be used for recessed models to cast-in-pla whin new concrete KIT DIMENSIONS or masonry construction.The KnoxBox is mounted into th shell ousing after Rough-in Dimensions: construction is completed. / 6-1/2"H x 6-1/2"W x 5"D Recessed Mounting RMK shed/ Using Recess mount din wall Mounting Kit(RMK) cons ruction cons ruction KnoxBox / mounts inside Knockouts for RMK shell after alarm wire conduit completion of construction 1• IMPORTANT: v Trim rebar for tie-in lh_,e are should be taken to ensure the front of the / towallif ecess Mounting Kit(RMK) shell housing, including I el ® I necessary cover plate and screw heads, is flush with the ll. The RMK must be plumbed to ensure vertical �gnment of the box. a Recessed Flange \ Mou mg studs Concrete or provided insi RMK shell masonry wall to a commodate construction KnoxBox ABOUT KNOX COMPANY Over forty years ago, a unique concept in rapid access for emergency\resonse KNOX COMPANY was born. The KnoxBox°, a high-security key lock box, was designed tvide 1601 W. DEER VALLEY RD rapid access for emergency responders to reduce response times, minimize PHOENIX, AZ 85027 injuries and protect property from forced entry. T. 800.552.5669 Today, one revolutionary lock box has grown into a complete system providing F. 623.687.2290 rapid access for public safety agencies, industries, military, and property KNOXBOX.COM owners across the world. The Knox Company is trusted by over 14,000 fire INFO@KNOXBOX.COM departments, law enforcement agencies, and gpka�eennt� ities. Page 83 VESDA-E VEP + xtralis VEP-A00-1 P, VEP-A00-P, VEP-A10-P The VESDA-E VEP series of smoke detectors bring the latest and most advanced detection technology to provide very early ' warning and the best nuisance alarm rejection to a wide range of applications. Built on the Flair detection technology and years of application experience,VEP detectors achieve consistent p formance over their lifetime via absolute calibration. In addition, th VEP delivers a range of revolutidnary features that provide user valu . Flair etection Technology Flair is t e revolutionary detection chamber that forms the core of the VESDA-E V providing higher stability and increased ngevity. Direct imaging of the sampled particles using a CMOS ima r combined with multiple photo- diodes alto better detection and fewer nuisance alarms. Installation, mmissioning and Operation VESDA-E VEP is eq ' ped with a powerful aspirator that enables use o a total of 130m(427ft)of sampling pipe in the one pipe mode nd 560m(1,837ft)of pipe in the four pipe del.Out of box operation is made possible with AutoConfig which a ws airflow normalisation and Auto Lear Smoke and Flowto be initiated from within the detector.VEP is fully supp ed by the ASPIRE and Xtralis VSC ftware applications which facilitate ease of pipe network design,system com 'ssioning and maintenance. VESDAnet' VESDA devices communicate on VIES etwhich pro "des a robust bi-directional communication network allowing continued redundant operation even duri single p int wiring failures.VESDAnet enables primary reporting, centralized configuration,control,maintena e a monitoring. Ethernet connectivity VESDA-E detectors offer connectivity to cor orate n tworks via Ethernet,allowing for devices installed with Xtralis monitoring and configuration software to onnecttot detector. Backward Compatibility VESDA-E VEP is compatible with exi ting VESDA installations. he detector occupies the same mounting footprint, pipe,conduit and electrical conne for positioning as VESDA VL VEP is also compatible with existing VESDAnet installations allowing monitorin of both VESDA-E and legacy det tors via the latest VESDA application. Features stick • Suitable for/and Div' ion 2 applications-Groups A,B,C&D Two programm\bG (1 monitored)for flexible remote control • One and fom els for different applications Field replaceasemblies enable faster service and Flair detecth 0logydelivers reliable very early warning ina maximum uptiwiderangenments with minimal nuisance alarms Listings/Aps • Multistage n and optical protection with clean air barriers UL ensures lifetection performance ULC • Four alarm nd a wide sensitivity range deliver optimum CSFM protectionfidest range of applications FM IntuitiveLCdisplay provides instant status information for VdS immediate response NF-SSI(www.marque-nfcom) • Flow faultthresholds per port accommodate varying airflow VNIIPO conditions CE • Smart on-board filter retains dust count and remaining filter life ActivFire for predictable maintenance CCC • Extensive event log(20,000 events)for event analysis and system EN 54-20,ISO 7240-20 diagnostics Four Pipe VEP • AutoLearn'"smoke and flow for reliable and rapid commissioning EN 54-20,ISO 7240-20 • Referencing to accommodate external environmental conditions - Class A(40 holes/Fire 1-0.028%obs/m) to minimise nuisance alarms - Class B(80 holes/Fire 1-0.027%obs/m) • Backward compatible with VLP and VESDAnet - Class C(100 holes/Fire 1=0.056%obs/m) • Remote monitoring with iVESDA for system review and proactive Classification of any configuration is determined using ASPIRE. maintenance Ethernet for connectivity with Xtralis software for configuration, Regional approvals listings and regulatory compliance vary between product secondary monitoring and maintenance models.Refer to www.xtratis.com forthe latest product approvals matrix. Page 84 VESDA-E VEP xtralis® TECHNICAL SPECIFICATIONS Specifications 3.5" Display One Pipe VEP Four Pipe VEP Supply Voltage 18-30 VDC(24 V Nominal) el VEYA10jZm NN Wri l9 Zw Name Power Consumption @ VEP-A00-1P VEP-A00-P VEP-AI0-P A •'10°x'm 4 24VDC A _ Aspirator Setting Fixed 1 5 1 5 1 + %0 _ F Power(Quiescent) 8.8 W 7.0 W 8.8 W 8.2 W 10.0 W C/i oL n? Power(In Alarm) 9.6 W 7.8 W 9.6 W 10.4 W 11.6 W l a, Dimensions(WHD) 350 mm x 225 mm x 135 mm(13.8 in x 8.9 in x 5.3 in) Weight 4.4 kg(9.7 lbs) 4.4 kg(9.7 lbs) 4.5 kg(9.9 Lbs) LED Description \Humidi °C to 39°C(32°F to 102°F) ir:-20°C to 600C(-4°F to 140°F) Q Fire 2 Operating Conditions -20°Cto55°C(-4°Fto131°F) -20°C to 50°C(-4°Fto 122°F) Fire 1 5%to 95%RH,non-condensing 1,000 mz Action (10,760 sq. Area Coverage ft 2,000 mz(21,520 sq.ft) Q Alert Min.airflow per pipe 15 Vm Pipe Length(Linear) 100 m(328 ft) 0 m(919 ft) Q Disabled Pipe Length(Branched) 130 m(427 ft) 560 (1,837 ft) Fault Pipe Lengths depending 1 Pipe 1 Pipe Pipe 3 Pipe 4 Pipe I Power on number of pipes in use 100 m (328 ft) 110 m 10 80 m 70 m (361 ft) (328 (262 ft) (230 ft) Stax PSU PSU,Auto Pipe Clean Home Page No.of holes(A/B/C) 30/40/45 40/80/100 Icon on Display Description Computer design tool ASPIRE Smoke and Alarm Threshold Levels Inlet:External diameter 25 mm or 1.05 in(3/4 in IPS) Pipe Exhaust:External diameter 25 mm or 1.05 in(3/4 in IPS) C Detector OK adaptor Relays 7 programmable relays(latching or non-latching states) Detector Fault Contacts rated 2 A @ 30 VDC(Resistive) I P rating I P40 Aspirator Fault Cable access 4 x 26 mm(1.02 in)cable entries Airflow Fault Cable termination Screw Terminal blocks 0.2-2.5 sq mm(24-14 AWG) Power Fault Dynamic Range 0.000%lm to 32%/m(0.0000%/ft to 10%/ft) Sensitivity Range 0.005 to 20%obs/m(0.0016%to 6.25%obs/ft) '7y Filter Fault Alert:0.005%to 2.0%obs/m(0.0016%to 0.625%obs/ft) Smo Chamber Fault Threshold setting range Action:0.0055%to 2.0%obs/m(0.00160/oto 0.62o5%obs/ft) r Firel:0.010/o to 2.0/o obs/m(0.0031/o to 0.625/o obs/ft) Fire2:0.020%to20.0%obs/m(0.0063%to6.25%obs/ft) VESDAnet ult Event log:Up to 20,000 events �Q StaX Module Fa Smoke level,user actions,alarms and faults with time and Software features date stamp AutoLearn:Detector learns Alarm Thresholds and Flow Fault thresholds by monitoring the environment. Ordering Information Ordering Code Description Spare Parts VEP-A00-11? VESDA-E VEP with LEDs,1 pipe.Plastic Enclosu e VSP-960 VESDA-E Mounting Bracket VSP-964-03 [VESDA-E MSD3-E Smoke Detection Chamber VEP-A00 P VESDA-E VEP with LEDs,4 pipe,Plastic Enclosure VEP-AI0-P VESDA-E VEP with 3.5-Display.4 pipe,Plastic VSP-961 VESDA-E Exhaust adaptor US VSP-965 Sampling Module Enclosure VSP-962 VESDA-E I-filler VSP-968 SDA-E VEP-A00-P/1P Front Cuver astic(LEDs) Approvals Compliance VSP-962-20 VESDA-E Filter-20 Pieces VSP-969 VESDA-E VEP-AlO-P Front Cover Plastic(3.5'Display) Please referto the Product Guide for details VSP-963 VCSDA-C Aspirator VKT-860 VCSDA-C VEP Demo Kit regarding compliant design,installation and commissioning. VSP-964 VCSDA-C Smoke Detection Chamber Page 85 XTRALIS POWER SUPPLIES4� xtrafis VPS-1000S, VPS-3000S The Xtralis Power Supply is capable of providing operating power including battery backup for the entire VESDA Laser Smoke Detector product line and VESDA-E detectors.The Xtralis Power Supply has been designed to power a single unit to multiple units depending on application needs.It �( provides 24 volt operating power to the VESDA or VESDA-E system as well as a battery charger function which supervises and maintains the standby ( batterie oxtr Installatio _ a115" The Xtralis Pow Supply models VPS-100US and VPS300US are »` " = power-limited po r supplies.They convert 120 VAC/60 Hz input into 24 VDC power-limited outputs.The VPS units are intended for use' applications requiring UL,ULC and CSFM listing for fire protection signalling. The VPS-100US orVP 300US shall be installed in accordance with the National Electric Code(NFPA 70)and in accordance with any loca regulations.See the wiring diagram on the second page for proper assembly. Fault Reporting A Power Supply Fault indicator is ovided via a dry relay contact(Form C),which changes state due to the following conditions: • AC input loss • Low AC inputvoltage(Brown-out) • Loss of battery voltage • A short circuit of the battery leads • A short circuit of any of the DC power outputs Components The VPS-100US consists of three main components:the m nting enclosure,the transformer and the main circuit board. It uses two backup batteries(supplied separately). The VPS300US consists of one VPS-100US Power Supply and o VBC-001 Battery Cabinet.Together the two units can hold up to 6 batteries(supplied separately). Note:The Xtralis Power Supply uses sealed acid, 12VDC, 12 Amp/hou atteries.To order,use part number VBT-012(minimum 2). Features Listings/Approvals • Input 120 VAC/60 Hz UL 1481 listed • 1.5 amp continuous supply current at 27.6 VDC ULC • Filtered and electronically regulated output FM (for VPS-1000S) • AC fail supervision CSFM • Low AC(brown-out)supervision • Battery supervision • Built-in charger for sealed lead acid or gel-type batteries • Automatic switch over to standby battery when AC fails • AC input LED indicator Page 86 XTRALIS POWER SUPPLIES xtralis® TECHNICAL SPECIFICATIONS Battery Calculations To facilitate the calculation of the backup battery size,refer to the Battery Calculator (Doc. No.21062),available on Xtralis website(www.xtralis.com). The battery calculation has to be confirmed to the compliance requirements with localfire protection codes and standards. a� POWERS-PPLY CI b Transfr^er • O .mites • r O - Ited •' z _utp.te _• L ,, — ! • ' II T_120VAC/60—Z Q• I m I Co-nett to ced cared ° 2 branch dreu t for fire a.arm use Q Battery 0 Battary _2V/12AH 12V/1ZAH �0 kAG)) V=S-100 us UeMry 2V/12AH 12V/MH 0 O 1lallcry O lisp^ry '%V/I%All I%V/I'•AII IG 0 VBC-001 Specifications Input 120 VAC(+10%/-15%),60Hz,1.4 amp max. Output Voltage 27.6 VDC(Nominal)1.5 Amps(Max.) Max.Output Current When a single 24 VDC output is used:1.2 amps When the three 24 VDC outputs are used:0.500 amps per output Dimensions(WHD) 13.9 in.x 9 in.x 4.5 in. Weight VPS-100 US 10 tbs.without batteries VBC-0016 lbs.without batteries Ambient:32°to 120 IF Operating Conditions Humidity:l0-95%RH,non-condensing Trouble Relay Rated 2A @ 30VDC(Form C:NO/NC) During normal operation,the power supply Fault Reporting Relay is energized. Cable Access 3/4'knockouts in various positions Cable Termination Screw Terminal blocks(30-12 AWG) Ordering Information Ordering Code Description VPS-1000S-XXX Power Supply Use XXX field to specify input voltage: 120 or 220 VAC VPS-3000S-XXX Power Supply Model VPS-1000S-XXX Use XXX field to specify input voltage: plus Battery Cabinet model VBC-001 120 or 220 VAC VBT-012 Battery,sealed lead acid,12 VDC, Minimum 2 batteries are required 12 Amp/hr • Page 87 VESDA PIPES & FITTINGS xtralis® Reliable smoke detection systems are dependent on a network of specialty piping that constantly and efficiently carry air samples from protected zones to highly sensitive detectors. s -a - - - VESDA Pipe and Fittin are part of an integrated system manufactured from spe ialty plastics designed for use with most " aspirating smoke detecti n systems. [Pil s" The Concept __ _. The quality of VESDA pipe ha been specifically chosen to surpass the requirements for most sys ms and aims to provide: • A"one-stop"shopping ford tector,pipe and fittings-thus saving procurement time and costs • An easy and professional ins allation • A competitive solution,includi g a Fast-Track ordering and delivery service • Committed customer service wi full technical advice and support on design and installation • Design verification using the very l test ASPIRE Pipe Modeling software • Commissioning,advice,service,and stem performance testing The VESDA pipe range is based on pipewor of a standard inside diameter OD)of 3/4". VESDA aspirating smoke detection is an early arning system that detects fire in the incipient stages-before flames are visible-by detecting the products of pre-co bustion in the air around the area about to ignite. The VESDA detector family is the result of extensiv research and development.Using unique detection principles,the detector provides a sensitivity range of 0.0015 to 60 obscuration/ft. It detects fire at the earliest possible stage and reliably measures very low to extremely high concentra ions of smoke. The VESDA system samples air from afire zone for the p\tothedetector. of smoke.The air sampling system makes this possible by providing the means for transporting air from afire zo The air sampling system is active,continuously drawingmples by means of an integral pump.It does not rely on air or heat currents in the vicinity of the detector transpo smoke particles to the detector.The VESDA system can function effectively in all kinds of environments from high ai flows to still air. The network of sampling pipes to the detector is the key element i the performance of the detection system. Features • UL1887 Listed for use in Plenum Rated Areas Simplifies pecifiers'and installers'tasksnd saves • An integrated CPVC Pipe&Fittings package designed time and m ney for use with VESDA Aspirating Smoke Detection Pre-labeled ' es in accordance with NFPA 72 Systems Requirements • Simplifies the selection of Pipe&Fittings to ensure the correct product is installed Page 87 Page 88 VESDA PIPES & FITTINGS xtralis® Air Sampling Three basic sampling methods can be used in an VESDA system installation: • Standard pipe sampling systems(below ceiling;in ceiling or floor void). • Capillary tube sampling(concealed;above ceiling;within cabinets). • Return air sampling(within duct;return air grille). Figure 1:A typical below ceiling sampling installation Figure 2:A typical concealed sampling installation. I he sampling point rilliny places the sampling help more than 25mm U inch)below the ceiling panel or tile. Sampling pipe network at ceiling level Sampling Pipe VESDA FPT Pipe Tee (VP-P-)()()) Detector (VP-TEE-FPT) Capillary Tuber Capillary Tu be (E700-Tube) Connectors (E700-CAP-KIT) YET Ceiling Tde Miniature VESDA Sampling Point (E700-SP) Figure 3:Sampling from a return air grille VESDA-E Detector Return air duct grille Sealed endcaps ampling pipes Standoff posts Standoff posts While each sampling method is suited to specific applications,more than one method is often effectively employed to monitor a firezone. In some applications-particularly those in which there is movement of high volumes of air—the most effective sampling network generally combines two methods to provide maximum coverage to a zone under all operating conditions. System Description VESDA piping systems are produced from specialty thermoplastics that offer unique benefits. Piping systems are lightweight,and assembled easily in the field using inexpensive tools.The one-step solvent cementjoining processensures fast reliable connections. In addition to ease of installation,this unique piping system offers enhanced flow characteristics and exceptional fire performance properties. The complete system includes all of the components necessary to install and test the system.This includes: pipe,a comprehensive range of fittings,capillary tube,a variety of sample point configurations,and sampling point labels. Page 88 Page 89 VESDA PIPES & FITTINGS xtralis® ORDERING INFORMATION Part Numbers for System Components 1 VP-P-105 Pipe-3/4"(105 ft.kit)* VP-P-210 Pipe-3/4"(210 ft.kit)* 1 2 VP-P-420 Pipe-3/4"(420 ft.kit)* 2 VP-COUP Couplings-3/4",15 per box* 3 VP-ELB-45 45'Elbow-3/4",10 per box* 3 4 4 901 Elbow-3/4",20 per box* 5 VP-UNION Unions-3/4",10 per box* 6 VP-TEE Tee-3/4",15 per box* 5 6 7 VP-EC End Cap-3/4 25 per box* 8 VP-TEE-FPT Tee-3/4'x 3/4'x'/z'FPT,10 per box* 9 PIP-015 ush Sampling Point 7 8 10 E700-SP Min ture Sample Point 11 VSP-877 Flush untSampling Point 12 VSP-610-US Tamper Pr\bRf Sampling Point 9 LOD, 10 13 CAP-KIT Brass connec r kit for miniature sampling � .f point and capiLIAV tube arrangement. ` E700-CAP-KIT Connector Kits 14 E700-SP-DCL-PNT Sampling Point Label, 0 per roll 12 15 E700-SP-DCL Sampling Point Label,t round style,200 per roll 16 E700-SPLR Sampling Point Label,red,1 er sheet _ AMA 17 E700-SPLG Sampling Point Label,grey,8 pe sheet 13 ' 14 18 VSP-950 Test Point Pipe Labels. 19 E700-SP-DCL-PIPE Pipe Label,35 per roll j 20 VSP-870-US In-Line Flow RestrictorAssembly-US,f use 15 `� 16 with Tamper Proof Sampling Points (models VSP-610-US and VSP-620). 21 E700-TUBE Capillary Tube 3/8"internal diameter TUBING-250 Polyethylene tubing,black,1/2"OD X 3/8"ID, 17 18 " FIDE rated. 22 VP-CUTTERS Pipe Cutters 23 VSP-878 Push-in Connect Adaptor Kitfor'h"capillary 9 20 tubing 24 (VP-CLIP=US 3/4"pipe support clamp (required for each 5 feet of pipe). 21 22 (, 25 VP-CEMENT Solvent Cement,one pint 26 VP-BV Ball Valve,10 per box 23 24 *CPVC Pipe&Fittings 40 25 26 Page 89 Page 90 VESDA PIPES & FITTINGS xtralis® TECHNICAL SPECIFICATIONS Air Sampling Pipe Systems Pipe Dimensions VESDA Pipe systems are produced in 3/4"iron pipe size(IPS)pipe dimensions perASTM F442.This provides piping with unique flow characteristics and exceptionally smooth interiorwalls,greatly enhancing system performance. Nominal Size 3/4"(20mm) Average OD 1.050"(26.7mm) Average ID 0.874"(22.5mm) Pounds Per Feet 0.168 Operating Temperature R ge VESDA Pipe and Fittings are s 'table for a wide range of operating temperatures from 01F to 200°F.Although tough and durable,care should be exe ised in extremely cold environments to avoid unnecessary rough handling or other forms of mechanical damage. Flammability ating V-0 UL 94 Flame Retardant Limiting Oxygen\tqdex 60 ASTM D2863 Flame Spread 0 ULC Smoke Generation 0-25 ULC Flame Travel 4 UL 1887 Optical Density 0. 9 peak 0.03 Avg. UL 1887 Heat of Combustion 177 BTU's/lb. Physical Properties CPVC is a unique polymerwith many beneficial properties. en produced into pipe form,this product exhibits qualities that are extremely advantageous for use in air sampli g applications. It is light in weight,exhibits excellent physical,mechanical,and chemicaVcorrosion resistance prope ies,and offers exceptional fire performance. Cell Classification 23477 D1784 Specific Gravity 1.55 D792 Tensile Strength 8400 psi 638 Modulus of Elasticity 4.23 x10-5 D6 8 Compressive Strength 9600 psi D695 Izod Impact 3.0 D256A Coefficient of Linear 3.4 x 10-5 D696 Expansion Temperature Limit 0-200°F N/A Electrical Conductivity Non Conductor N/A • Pay a 90 p�nr� Q 1 © � © � 0 M M SYSTEM RECORD DOCUMENTS (SRD) BAKBOX SERIES Material: Boxes: #18 Gauge Steel with Red Powder Coat Textured RECORDSYSTEM Finish (Standard). DOCUMENTS Door: 418 Gauge Steel with Red Textured Finish (Standard). Hinge: Concealed Stainless Steel Piano Hinge Fastener: Standard 3/4" Cat 30 Key Lock (Other Lock Assemblies Available). Backbox Depth: 3.25" Surface: 14.25"w x 14.25"h Standard - Installed with 4 GB Additional digital flash drive with —thy a Features: USB B connector _ - Durable powder coat baked-on finish Kirkland manufactures code compliant solutions! Permanently screened The System Record Documents (SRD) from the BAKBOX SERIES is the perfect (1"h white ink) "SYSTEM item to meet demanding code requirements. NFPA 72 2013 7.7.2.5 states that RECORD DOCUMENTS a cabinet must be "prominently labeled 'SYSTEM RECORD DOCUMENTS'. NFPA 72 2013 7.7.2.1 states, "With every new system, a documentation cabinet - Legend sheet for doc- shall be installed at the system control unit or other approved location at umentation, passwords the protected premises." This durable #18 gauge steel enclosure with a stain- less steel piano hinge and key lock keeps your code-required documents, and system information. including but not limited to, test and inspection, service and system records, and manuals. In addition, a 4GB USB flash drive safely and secure- ly stores your fire alarm software, eliminating occurrences of the software not being on-site when technicians arrive to service the system. Using a stan- dard USB B connector you may also store records electronically (See NFPA 72 2013 7.5.6.7). The SRD is designed with a plan clip to keep your documents secured. The inside cover has a recordkeeping log for identifying equipment information and required documentation locations (See NFPA 72 2013 7.2.1). ORDERING INFORMATION PART NUMBER: MB3001 BAK DESCRIPTION:System Record Documents Box 180305 Kirkland Co., 14935Allison • .• 1 .. 1 :11 1 1 • 1 : . LICENSED BY THE N.Y.S. DEPARTMENT OF STATE NYS LICENSE #12000006636 FA CONNECT AND PROTECT A P AV ON COMPANY SCOPE OF WORK FIRE ALARM LEGEND FIRE ALARM NOTES 155 M CHAEL DRIVE SYMBOL DESCRIPTION MAN, MODEL NO. OTY. FACP & ANNUNCIATOR INFORMATION SYOSSET, NEW YORK 11791 1 . INSTALLATION OF NEW FIRE ALARM SYSTEM. 1. THE FIRE ALARM SYSTEM SHALL BE A NEW ADDRESSABLE SYSTEM, 51 6.496.2322 VOICE FACP FIRE ALARM CONTROL PANEL NOTIFIER NFS-320 01 2. THE FIRE ALARM CONTROL PANEL (FACP) SHALL BE LOCATED IN THE HALL. 3. ALL ALARMS SHALL BE TRANSMITTED BY A UL LISTED CC'MMUNICATOR TO UL LISTED CENTRAL STATION. 51 6.496.2848 FAX FAC FIRE ALARM COMMUNICATOR HONEYWELL IPGSM-4G 01 4. REMOTE ANNUNCIATOR SHALL BE READABLE AND VISIBLE FROM OUTSIDE THE BUILDING AND LOCATED AT THE MAIN ENTRANCE. SPRINKLER INFORMATION P'K f.-�ry— (, )^- OS P SMOKE DETECTOR / SENSOR - PHOTOELECTRIC NOTIFIER FSP-951 15 1. NO SPRINKLER SYSTEM AT THIS LOCATION. 70 NOTE, A [ABOVE C SMOKE DETECTOR / SENSOR - PHOTOELECTRIC NOTIFIER FSP-951 05 INITIATING DEVICES 70 3—Z Alf_ HVAC UNITS ARE ELECTRIC UNITS WITH NO 1. ALL EQUIPMENT SHALL BE INSTALLED IN COMPLIANCE WI-,H ALL LISTED DISTANCES, LOCAL ORDINANCES, NFPA-70, ROVED AS NOTED (t� SMOKE DETECTOR / SENSOR FOR DUCT NOTIFIER DNR 02 NFPA-72, AND NFPA-720 RECOMMENDATIONS. ,1 ed / )QL Su [SUPPLY SIDE] 2. ALL MANUAL PULL STATIONS SHALL BE MOUNTED 48-INCHES FROM FINISHED FLOOR TO THE TOP OF THE DEVICE. / y8��Z- CARBON MONOXIDE PRODUCING EQUIPMENT. SMOKE DETECTOR / SENSOR FOR DUCT � it#:A 13.p c� (bS NOTIFIER DNR 01 CARBON MONOXIDE INFORMATION ` ��-- � RT [RETURN SIDE] FEE gy;�r;-7 �- � 1. ALL CARBON MONOXIDE DETECTORS SHALL BE PROGRAMIAED AS A SUPERVISORY SIGNAL TO THE FACP PANEL & A CARBON N O SMOKE DETECTOR / SENSOR - NOTIFIER FSV-951 R 20 MONOXIDE ALARM SIGNAL TO CENTRAL STATION. NOTIFY FIRE MARSHAL AT 631-765-1802 o vlEw VERY INTELLIGENT EARLY WARNING 2. ALL CARBON MONOXIDE DETECTORS SHALL SHUT DOWN THE HVAC UNITS UPON ALARM SIGNAL. FOR THE FOLLOWING INSPECTIONS: HEAT DETECTOR / SENSOR WIRE LEGEND Oj F [FIXED] NOTIFIER FST-951 02 NOTIFICATION DEVICES 1. ROUGH INSPECTION iN 1. ALL AUDIBLE STROBE DEVICES SHALL HAVE A TEMPORAL--3 CODE. 2. COMPLIANCE TESTING SYMBOL WIRE DESCRIPTION TYPE MAN. O FLAME DETECTOR - COMBINATION ULTRAVIOLET / NOTIFIER FSL-100-UV/IR 01 2. ALL STROBE DEVICES SHALL REMAIN ACTIVE AFTER SILENCE FUNCTION OCCURS. 3. rINAL INSPECTION UR IR INFRARED o A 1 PR #16 TWISTED UNSHIELDED FPLP BELDEN 3. ALL AUDIBLE/STROBE AND STROBE DEVICES SHALL BE MOUNTED 80-INCHES FROM THE FINISHED FLOOR TO THE BOTTOM OF THE ALL WORK SHALL COMPLY WITH NYS so SMOKE CARBON MONOXIDE DETECTOR CODES AND APPUCA13LE NFPA � �co NOTIFIER FCO-951 02 DEVICE. WITH SOUNDER BASE Q B 1 PR #14 TWISTED FPLP BELDEN SB CARBON MONOXIDE DETECTOR / SENSOR CEILING INFORMATION STANDARDS CO WITH SOUNDER BASE NOTIFIER FSCO-951 01 Ln F 2#10+1#IOGRD - 3/4"C. FPLP BELDEN 1. PLEASE REFER TO ELEVATION DETAILS FOR CEILING HEIGHTS AND CONSTRUCTION. 00 AIM ADDRESSABLE INPUT MONITOR MODULE NOTIFIER FMM-1 06 HVAC INFORMATION 1. ALL HVAC UNITS ARE ELECTRIC UNITS WITH NO CARBON MONOXIDE PRODUCING EQUIPMENT, m AIM ADDRESSABLE INPUT MONITOR MODULE - MINI NOTIFIER FMM-101 01 2. DUCT SMOKE DETECTORS SHALL BE INSTALLED AS REQUIRED BY THE MECHANICAL CODE OF NEW YORK STATE (SECTION 606 SMOKE DETECTION SYSTEMS CONTROL) AND IN ACCORDANCE WITH NFPA-72 & MANUFACTURERS SPECIFICATIONS. �„ 0� ADDRESSABLE OUTPUT RELAY MODULE NOTIFIER FRM-1 05 3. EACH HVAC UNIT SHALL SHUTDOWN UPON RECEIPT OF AIJY FIRE ALARM SIGNAL AND DUCT DETECTOR SUPERVISORY IN c ACCORDANCE WITH THE MECHANICAL CODE OF NEW YORK STATE (SECTION 606.4) AND LOCAL ORDINANCE. 0 4. MANUAL RESTART OF FANS REQUIRED. THE FAN RESTART SHALL BE INDEPENDENT OF THE RESET FUNCTION OF THE FIRE ALARM. o O�c ADDRESSABLE OUTPUT CONTROL MODULE NOTIFIER FCM-1 03 o COMMUNICATION PATHS NON ADDRESSABLE OUTPUT RELAY NOTIFIER MR-201 05 1. MULTIPLE TRANSMISSION PATHS SHALL BE SUPERVISED WITHIN NOT MORE THAN 6 HOURS. SINGLE TRANSMISSION PATH SHALL BE 74785 z SUPERVISED AT AN INTERVAL OF NOT MORE THAN 60 MIIJUTES. ❑F PULL STATION / FIRE ALARM BOX NOTIFIER NBG-12LX 04 CD MOUNTING INFORMATION ,RI SYSTEM 1. ALL WALL MOUNTED DEVICES WILL BE SECURELY MOUNTED ON BACKBOXES. o REMOTE INDICATOR SENSOR RA-100Z 05 2. ALL CEILING MOUNTED DEVICES FOR ALL SUSPENDED CEL-ING WILL BE SECURELY MOUNTED WITH BACKBOXES ON T-BARS. ZMP R� 30 COMBINATION HORN / VISIBLE SYSTEM Q `N [30CD1 SENSOR P2RL 12 Ln 75 COMBINATION HORN / VISIBLE SYSTEM P2RL 05 c [75CD] SENSOR r 75 COMBINATION HORN / VISIBLE SYSTEM Ewp [75CD][WEATHER PROOF] SENSOR P2RK 01 Li1 15 VISIBLE ONLY (STROBE) - WALL MOUNT SYSTEM (� SCALE: N.T.S. ;q; [,5CD] SENSOR SRL 02 SECTION: 4.� 10, co LOCATED WCARBON ITHIN 3FT FROM CO DEDE STROBE - ITECTOR LING MOUNTED SENSOR SCWL-CLR-ALERT 03 BLOCK: 4 LOT: 8,1 KB FIRE DEPARTMENT BOX / KNOX BOX KNOX KNOXBOX 3200 01 L' ? ADDRESS: 74785 MAIN RD SYSTEM > EOL RI END OF LINE DEVICE - RELAY SENSOR EOLR-1 01 �r z GREENPORT, N.Y. s s s s s s s s s I 11AR r' END OF LINE RESISTOR FURNISHED FURNISHED 03 vIEW IEW P P P P P P P 11944 BY OTHERS BY OTHERS D-40 D-41 D-42 D-43 D-44 D-45 D-46 D-47 D-48 I TYPICAL DEVICE LOCATIONS S s s s s s s s s s s s s s s z VIEW VIEW VIEW AEA IEW VIEW VIEW VIEW VIEW EW VIEW VIEW VIEW IEW VIEW w D-39 D-38 D-37 D-36 D-35 D-34 D-33 D-32 D-31 D-30 D-29 D-28 D-27 D-26 D-25 Z FCEILING C0 ,RI RI ,RI 12. 11 .2023 REVISED AS PER CONSTRUCTION CHANGES B 3 MINIMUMo\ , SMOKE DETECTOR I SB o s F sic s F s %C— F s sic s s s 11 . 15.2022 ORIGINAL RELEASE A I CO C P P P P P P VIEW VIEW IEW w AIR REGISTER I D-14 M-13 D-15 r M_18 - D_16 -D-17 -----D_18- D-19 M-28 D-20 D-21 - D-22 D-23 DATE DESCRIPTION REVISION I I DIESEL I I FAN I I FAN I ° ° I SHUTDOWNI co ISHUTDOWNI STATUS ISHUTDOWNI co PROJECT / TENANT INFORMATION BUILDING OWNER INFORMATION z ac, ^u I I � � i UR/IR I F F E v I STATUS EOL RL J r ion --- I STATUS RL RL Q —� L J L J --0----- .---J�J�— AUDIBLE/STROBE .R R- a I RI SBA ` SB ' I VERIZON STORE #32212 VERIZON STROBE AIM AIM 0 1 0 S AIM AIM 0 AIM 0 S 0 S I E E w I F C COI M RT C CO U Ln fa (acn c c c c — co B(24V) �- M-12 M-16 - M-11 -D-13 1 M-10 D-121 �i�=9 _ M 15FANM-I4--M-8 --M=7 -D-11-� M-6 FAN D-10 j I 74785 MAIN RD 1095 AVE OF THE AMERICAS o PULL STATION cn o SHUTDOWN SHUTDOWNI--- o Q -: € C: o o _ --- f GREENPORT N.Y. NEW YORK N.Y. --------------------------- I w 2 cn � . ,Rl � ,RI I > , U, -: ra cc `� a a ra a F- E ul v B NAC A DATA U I J FIRE ALARM i Q c o a ¢ O a� b U b 7 3 3 3 7 3 5 3 3 / AC y{c I I I I I P s N o _ o v ( ) RL STATUS RL STATUS 11944 10036 L� c� PULL DOwN ra c Z ru° m .. U c aa) v CKT 2 O o O O O O O O j F S S S S S 0 AIM S S S 0 AIM I ro c = c `-^ c o o ro .X 0 v 3 U U o> i F P P P P SU I I P P SU I I { 80" c "' ¢ c o p° o > � u c° v � v a v 2-9 2-8 2-7 2-6 2-5 2-4 2-3 2-2 2-1 D-1 M-1 D-2 D-3 D-4 D-5 D-6 I M-2 I M-3 D-7 D-8 D-9 I M-4 M-5 I PROJECT ENGINEER / ARCHITECT SYSTEM DESIGNER / INSTALLING CONTRACTOR _ ° _ 0 € _ Ln = a = CHARLES SCHNABO�K P.E. COMMANDER ELECTRIC >> _ +' ¢ c Y E cn fO � t9j ro o L ¢ a I r ¢ ¢ ° E n ¢ c +� cn n a ° aB(NAC) I I l > ¢ ra o to Z c v o s s v o a ¢ — ¢ �75-��L �30V �3q�;,' �, )5 3 �75VK�Z 3 7 3 7-0 CUv � v o �, o o CKT-1 o _ o 0 0 0 0 --------------------- L------------- 7000 KENNEDY BLVD 42A 500 JOHNSON AVENUE _ P -------------- c ' ¢ f6 < E �' ¢ o a� o c c 1-11 1-10 1-9 1-8 1-7 1-6 1-5 1-4 1-3 1-2 1-1 B(24V) p r- <J 0 ro ^ U ¢ aci ro u- M v v E m c rn W u ¢ zv ¢ E o c ¢ o z _ _ �, --------------------- ----------J GUTTENBERG N.J. 07093 BOHEMIA, N.Y. 11716 4-------------------------------- ¢ c o o ra o o. v a c +� co '—, to v a U to c o c 'ice _ � � Svc � o O fOf� -o ¢ S � `o o ° o > B(24V) ¢ � Lu UV) C 'ol` � > ` Ln Q? � o c o U of U ;TL ¢ o ¢ _ �' o a o v o 0 ' 8 FLOOR NUMBER: � ° � � �� � p 2 � a a o a FIRST FLOOR Evc a�i000- � aoia � � aa) moo a� o rUv � a) fa ¢ E ¢ � u') � E F(POWER) ` v ¢ V V o ~ a c ° o ° DRAWING TITLE: ¢ p cn pl¢i FL pl¢i m Q w o r'a raLn m C o0 >✓ U 8U _ tU F C m ` o FACP TO DEDICATED 120VAC IRE ALARM SYSTEM ¢ L > J 3 � ` y RADIO COMMUNICATION o vEi r�o U E > vE, > O ro '�" 0)Q -0 -0 '@ rru v •°o vE vEi En ° vE p vE � c a� = ac = ac v ° o � � � c c •E c •E c ;c c E FAC � om � om � oLn LnU 0 � M L � aao � � u � 2 � � � � � � TO CENTRAL STATION RISER DIAGRAM, LEGENDS, NOTES, PLOT PLAN System Inputs A B C D E F G H I J K L M FIRST FLOOR FIRST FLOOR 8c 1/O PROGRAMMING MATRIX w r� 1 Smoke Detector • O • • O N 2 Duct smoke Detector O O • • • SEAL & SIGNATURE: SHEET : 1 OF 2 3 Manual Pull Station • • O • • 4 Thermal Detector • • • • • 5 Carbon Monoxide-Installed at CO • O O • O IR I S F— R 01 A G RA M o � Source or Area Served b Source 6 Carbon Monoxide-Located in other • ® • DRAWN BY: C W. w o Location than CO Source • OF � CHECKED BY: c¢ 7 Flame Detector O • • O o g Sprinkler System Water Flow Switch • ® ® ® �'C�� CJ'`jCQ l� �. �- T.M. c� o or Pressure Switch 9 Sprinkler System Tamper Switch • �Q� ' `� 1 W0 E39139— 1 10 FACP and Sub-System AC Power Failure • • r � �; , SCALE: AS NOTED 11 FACP and Sub-System Low Battery Capacity • • a 12 Open Circuit • • — 13 Ground Fault • • 1'y;sd `pt. r CONTACT: ... ~ 0 14 Notification Appliance Circuit Short • • ", ,rr �Jry�i�, l Aspiration Smoke Detection System Inputs g w 15 "Alert"Condition at ASDU • • DRAWING NO: o N 16 FACP Power Failure • O • • O 17 FACP Power Failure • • ^ r�+, ��� / o INPUT OUTPUT MATRIX ROTE S �4,,.�`, LICENSED BY THE N.Y.S. DEPARTMENT OF STATE NYS LICENSE #12000006636 ELEVATION DETAILS SCALE 1/8" - V-0" 0 ; DROP CEILING TYPICAL UNLESS OTHERWISE NOTED. RIGID STEEL DECK CONNECT AND PROTECT A PAV ON COMPANY ACCESSIBLE, SWITCHMER, NON-COMBUSTIBLE POWER ROOM, & PLENUM RETURN POWER ROOM, GENERATOR DROP CEILING IN ROOM, 15'-0" 155 MICHAEL DRIVE OFFICE SPACE, COMPRESSOR- BATHROOMS DEHYDRATOR (TYPICAL) 9 0 ROOM (TYPICAL) , W Y RK 11791 516.496.2322 VOICE 516.49 6.2848 FAX COMPRESS / DYHRATOR I I CABLE VAULT ° � I JAN _ _ o � /RI /2-3 D-1 O O (DP \ ,N AC P P REST OPOOp D-47 D-45 D-43 /RI OF D-20 D-21 r-------------------------------------------------i ROOM 1�p C MDF �I CP Q 30V D D-4 CD O 2-7 -__ - F F --------------------------------------- D-42 O M-28 O 3 OP D-46 O S M-1 P p FAC FACP 2-2 O D-48 o 2 6 D-44 HALL p_3 O S AC`•,RI 2-5 O POP /1\ KB LLJ D-2 z D-23 S O O O ° $ p W VIEW VIEW D-221EW STOR W AC - 2 O o — O + D-24 0 + o 206-01-02 FAN z 2-8 2-1 SHUTDOWN LLJ 5 ESS MCC TOLL TRANSMISSI 0 RL STATUS MAP RM �RI FAN D-7 O Osu 0 AIM o LEI D-6 M-2 M-3 z , `AC SHUTDOWN Op S P RL STATUS TRANE w 00 D-18 D-19 OS RT 0 AIM D-11 M-7 M-8 2 6C 01 101 FAN r SHUTDOWN z w - RL STATUS O OIEW DIEW DIEW W O 0 AIM D-25 D-26 D-27 0 = SU D-9 M-4 M-5 o CO O SB 0 1-3 " i Taco IR — - + O FAN O + �'�' D-10 M-6 O — SHUTDOWN 2-9 o L 1-2 LLJ N RL STATUS 0 AIM Q IESEL o M-14 M-15 O M-i l SHUTDOWN OI O M-9 AIM MR/IR 0� RL u1 W w O OIEW VIEW DIEW DIEW DIEW \O/ CONTROL D-32 D-31 D-30 D-29 D-28 ' PANEL Ol F 0 z M-10B oOC D-13 w O 12. 1 1 .2023 REVISED AS PER CONSTRUCTION CHANGES B Q S co O o EOL RI STATUS o 11 . 15.2022 ORIGINAL RELEASE I D-t2 �- z AIM AIM A L Li EMERG PCWER M-16 M-12 DATE DESCRIPTION REVISION � CD O PROJECT / TENANT INFORMATION BUILDING OWNER INFORMATION CD M 13 Qw VERIZON STORE #32212 VERIZON — o V O IR CO 5 ESS SW + DIEW S� o + 74785 MAIN RD 1095 AVE OF THE AMERICAS W '-" s OIEWs '-6 D-36D 14 "'1-5 GREENPORT, N.Y. NEW YORK, N.Y. OIEW OIEW 11944 . 10036 �S D-33 D-34 D-35 VIEW D-37 PROJECT ENGINEER / ARCHITECT SYSTEM DESIGNER / INSTALLING CONTRACTOR o CHARLES SCHNABOLK, P.E. COMMANDER ELECTRIC 1-1D S VIEW 7000 KENNEDY BLVD 42A 500 JOHNSON _AVENUE _ o BATTERIES POWER D-38 M_t9 GUTTENBERG, N.J. 07093 BOHEMIA, N.Y. 11716 Q F VACANT ,RI EQUIP SUPPORT FLOOR NUMBER: DIEW DIEW DIEW FIRST FLOOR D-41 D-40 D-39 O J�pcOP . , P D-17 D-16 D-15 1-7 DRAWING TITLE: 0 3 \ )5 CO LUNCH RM o FIRE ALARM SYSTEM 0o [01 1-9 1-8� LUNCH RM F -18 M FLOOR PLANS & ELEVATIONS I :�E o MAN ROAD SEAL & SIGNATURE: i SHEET : 2 OF 2 w DRAWN BY: C.W. Q � C CD oscl CHECKED BY: 0 ., E39139- 1 R o cn � wo FIRST FLOOR PLAN � �� ,� � � SCALE: N ,.� ��:��� U,�����. AS NOTED FIRE ALARM SYSTEM SCALE:1/8"=1'-0° CONTACT: DRAWING NO: CD A AFA=002 , 00 LICENSED BY THE N.Y.S. DEPARTMENT OF STATE NYS LICENSE #12000006636 CONNECT AND PROTECT A PAV ON COMPANY SCOPE OF WORK FIRE ALARM LEGEND FIRE ALARM NOTES 155 M CHAEL DRIVE INSTALLATION OF NEW FIRE ALARM SYSTEM. SYMBOL DESCRIPTION MAN. MODEL NO. O• FACP & ANNUNCIATOR INFORMATION SYOSSET, NEW YORK 11791 1 ' 1. THE FIRE ALARM SYSTEM SHALL BE A NEW ADDRESSABLE SYSTEM. 51 6.496,2322 VOICE FRCP FIRE ALARM CONTROL PANEL NOTIFIER NFS-320 01 2. THE FIRE ALARM CONTROL PANEL (FACP) SHALL BE LOCATED IN THE HALL. 3. ALL ALARMS SHALL BE TRANSMITTED BY A UL LISTED COMMUNICATOR TO UL LISTED CENTRAL STATION. 51 6.496.2848 FAX FAC FIRE ALARM COMMUNICATOR HONEYWELL IPGSM-4G 01 4, REMOTE ANNUNCIATOR SHALL BE READABLE AND VISIBLE FROM OUTSIDE THE BUILDING AND LOCATED AT THE MAIN ENTRANCE. QS SMOKE DETECTOR / SENSOR - PHOTOELECTRIC NOTIFIER FSP-951 15 SPRINKLER INFORMATION �,�Rod T"c� � J ClJ P 1. NO SPRINKLER SYSTEM AT THIS LOCATION. NOTE. S AC SMOKE DETECTOR / SENSOR - PHOTOELECTRIC � NOTIFIER FSP-951 05 INITIATING DEVICES �� OP [ABOVE CEILING] �,/�� ALL HVAC UNITS ARE ELECTRIC C UNITS WITH NO 1. ALL EQUIPMENT SHALL BE INSTALLED IN COMPLIANCE WITH ALL LISTED DISTANCES, LOCAL ORDINANCES, NFPA-70, _, Zd 1�" 6SMOKE DETECTOR / SENSOR FOR DUCT NOTIFIER DNR 02 NFPA-72, AND NFPA-720 RECOMMENDATIONS. J�J �Z su [SUPPLY SIDE] 2. ALL MANUAL PULL STATIONS SHALL BE MOUNTED 48-INCHES FROM FINISHED FLOOR TO THE TOP OF THE DEVICE. ��j �`' � / 1'O*nil''Y�'jR �•,�r CARBON MONOXIDE PRODUCING EQUIPMENT. /I SMOKE DETECTOR / SENSOR FOR DUCT NOTIFIER DNR 01 f Gn THE FOILOV����a pjS ECi!®N :v� o (/RT [RETURN SIDE] CARBON MONOXIDE INFORMATION , � 0 1. ALL CARBON MONOXIDE DETECTORS SHALL BE PROGRAK'MED AS A SUPERVISORY SIGNAL TO THE FACP PANEL & A CARBON r� POUG14 JNSpE�O;; PI) O SMOKE DETECTOR SENSOR - NOTIFIER FSV-951R 20 MONOXIDE ALARM SIGNAL TO CENTRAL STATION. sue. CO��gCs,��® N vlEw VERY INTELLIGENT EARLY WARNING 2, ALL CARBON MONOXIDE DETECTORS SHALL SHUT DOWN THE HVAC UNITS UPON ALARM SIGNAL. �, iY'':I►t.l1'dSpE o HEAT DETECTOR / SENSOR CnON o WIRE LEGEND Oj F [FIXED] NOTIFIER FST-951 02 NOTIFICATION DEVICES AL w011KS,HALLCoMpLY MTN NYS N SYMBOL WIRE_ DESCRIPTION TYPE MAN. FLAME DETECTOR - COMBINATION ULTRAVIOLET / 1. ALL AUDIBLE/STROBE DEVICES SHALL HAVE A TEMPOP,AI -3 CODE CODESAND tnpUCI NF pA OUR/IR INFRARED NOTIFIER FSL-100-UV/IR 01 2, ALL STROBE DEVICES SHALL REMAIN ACTIVE AFTER SI_ENCE FUNCTION OCCURS. £TAND!AgDq o A 1 PR #16 TWISTED UNSHIELDED FPLP BELDEN se SMOKE / CARBON MONOXIDE DETECTOR 3. ALL AUDIBLE/STROBE AND STROBE DEVICES SHALL BE MOUNTED 80-INCHES FROM THE FINISHED FLOOR TO THE BOTTOM OF THE co WITH SOUNDER BASE NOTIFIER FCO-951 02 DEVICE. #14 TWISTED FPLP BELDEN S NOTIFIER FSCO-951 01 B CARBON MONOXIDE DETECTOR B 1 PF; / SENSOR CEILING INFORMATION ®CO WITH SOUNDER BASE 1. PLEASE REFER TO ELEVATION DETAILS FOR CEILING HEIGHTS AND CONSTRUCTION. Ln 00 F 2#10+1�10GRD - 3/4"C. FPLP BELDEN Ir►^^�'• -- � AIM ADDRESSABLE INPUT MONITOR MODULE NOTIFIER FMM-1 06 HVAC INFORMATION " 1 1. ALL HVAC UNITS ARE ELECTRIC UNITS WITH NO CARBON MONOXIDE PRODUCING EQUIPMENT. ------ ADDRESSABLE INPUT MONITOR MODULE - MINI NOTIFIER FMM-101 01 2. DUCT SMOKE DETECTORS SHALL BE INSTALLED AS REQUIRED BY THE MECHANICAL CODE OF NEW YORK STATE (SECTION 606 - M LE SMOKE DETECTION SYSTEMS CONTROL) AND IN ACCORDANCE WITH NFPA-72 & MANUFACTURERS SPECIFICATIONS, ► � — � - C,, 0� ADDRESSABLE OUTPUT RELAY MODULE NOTIFIER FIRM-1 05 3. EACH HVAC UNIT SHALL SHUTDOWN UPON RECEIPT OF .ANY FIRE ALARM SIGNAL AND DUCT DETECTOR SUPERVISORY IN NOTIFY FIRE MARSHAL AT 631-765-1802, CD ACCORDANCE WITH THE MECHANICAL CODE OF NEW YORK STATE (SECTION 606.4) AND LOCAL ORDINANCE. FOR THE FOLLOWING INSPlrgT�NS•. 0 4. MANUAL RESTART OF FANS REQUIRED. THE FAN RESTART SHALL BE INDEPENDENT OF THE RESET FUNCTION OF THE FIRE ALARM. �'R' I'l," y""w""r''�" IlgOt '- i40. < o OOc ADDRESSABLE OUTPUT CONTROL MODULE NOTIFIER FCM-1 03 COMMUNICATION PATHS CDRL NON ADDRESSABLE OUTPUT RELAY NOTIFIER MR-201 05 1. MULTIPLE TRANSMISSION PATHS SHALL BE SUPERVISED WITHIN NOT MORE THAN 6 HOURS. SINGLE TRANSMISSION PATH SHALL BE , '- GOMPLIlA1V�ITfj' u ; z 74785 z SUPERVISED AT AN INTERVAL OF NOT MORE THAN 60 MINUTES. '�t-INSP v�I ❑F PULL STATION / FIRE ALARM BOX NOTIFIER NBG-12LX 04 „'A1 LCOM �v �v MOUNTING INFORMATION YOAB N� 1 ,RI REMOTE INDICATOR SYSTEM RA-100Z 05 1. ALL WALL MOUNTED DEVICES WILL BE SECURELY MOUNTED ON BACKBOXES. a - , ¢o /1� SENSOR 2. ALL CEILING MOUNTED DEVICES FOR ALL SUSPENDED CEILING WILL BE SECURELY MOUNTED WITH BACKBOXES ON T-BARS. z MP RQ 1 30 COMBINATION HORN / VISIBLE SYSTEM N � [30CD] SENSOR P2RL 12 M Ln 75 COMBINATION HORN / VISIBLE SYSTEM P2RL 05 o [75CD] SENSOR 75V COMBINATION HORN / VISIBLE SYSTEM P2RK 01 I�A IV Ewp [75CD][WEATHER PROOF] SENSOR �N� 15 VISIBLE ONLY (STROBE) - WALL MOUNT SYSTEM SCALE: N.T.S. ;Q. [15CD] SENSOR SRL 02 W ED SYSTEM SECTION: 45 10, co LOCATEDWITHINID3FTSFROM CO DEETECTOROUN[30CD] SENSOR SCWL-CLR-ALERT 03 >1 r > BLOCK: 4 uL U \j, z KB FIRE DEPARTMENT BOX / KNOX BOX KNOX KNOXBOX 3200 01 LOT: 8.1 ADDRESS: 74785 MAIN RD, EOL RI END OF LINE DEVICE - RELAY SYSTEM SENSOR EOLR-1 01 z GREENPORT, N.Y. s s s s s s s s s END OF LINE RESISTOR FURNISHED FURNISHED 03 Ew VIEW P P P P P P P v-) 11944 ''� BY OTHERS BY OTHERS D-40 D-41 D-42 D-43 D-44 D-45 D-46 D-47 D-48 z 0 J I C' TYPICAL DEVICE LOCATIONS S s s s s s s s s s s s s s s z IEW VIEW VIEW EW IEW VIEW VIEW EW VIEW VIEW EW VIEW IEW EW VIEW iz w D-39 D-38 D-37 D-36 D-35 D-34 D-33 D-32 D-31 D-30 D-29 D-28 D-27 D-26 D-25 z CEILING w CO /RI ,RI ,RI 12. 11 .2023 REVISED AS PER CONSTRUCTION CHANGES B 3 MINIMUM sac C c SMOKE DETECTOR I SB 0 S F S S F S S F S S S S S 1 1 . 15.2022 ORIGINAL RELEASE A I CO O P P P P P P P VIEW VIEW IEw AIR REGISTER I D-14 M-13 D-15 r M_18- D_16 -D-17 -M-19--D_18- D-19 M-28 D-20 D-21 -D-22 -D-23--D_24-- o ° ° 1 SHDIESEL I CC ISHUFAN I I FAN TDOWNI ISHUTDOWNI Co ; DATE DESCRIPTION REVISION o I I %___ i UR/IR I STATUS 1 _ I PROJECT / TENANT INFORMATION BUILDING OWNER INFORMATION L J I i I - O_---- --Jl-1L- E v I STATUS EOL RI RL J -,SB I SB AUDIBLE/STROBE 1 R E R R STROBE .� I STATUS RL RL I I I VERIZON STORE #32212 VERIZON o m C� E E W I AIM AIM 0 j F l O C S COI AIM M AIM 0 AIM 0 S RT I O C S CO I �- o c'z, =o =o B(24V) - M-12 M-16 - M-11 -D-13-i M-10 D-121 i M-9 - M-15 ------ --M_7 -D-11---� M-6 D-10 I i 74785 MAIN RD 1095 AVE OF THE AMERICAS n _ �JL-- 00 L PULL STATION `-° a, ro L U rra FAN FAN I o a = o o o _ m � +� --- ----- SHUTDOWN SHUTDOWNI--- GREENPORT N.Y. NEW YORK N.Y. ---------------- I L c �, cn ,., (n /RI /RI I > > CL w PIRE ALARM u o a E °��' �° p `�° U ° 7 3 3 3 7 3 15 3 3 B NAC A DATA , AC C ' I ` I I I J PUSH o ¢ � '- o �, �, �, -a ( ) ( ) RL STATUS RL STATUS I 119 44 V- c:� PULL DOWN ro c Z fu = ami i � u c v v v CKT 2 0 0 o O O o o o j F S S S S S 0 AIM S S S 0 AIM I 10036 fO o ro ._ o L L c v u > u F P P P P SU I P P SU 80» - $ c > o $ n o 10 v v v 2-9 2-8 2-7 2-6 2-5 2-4 2-3 2-2 2-1 D-1 M-1 D-2 D-3 D-4 D-5 D-6 I M-2 M-3 D-7 D-8 D-9 I M-4 M-5 i PROJECT ENGINEER / ARCHITECT SYSTEM DESIGNER / INSTALLING CONTRACTOR : L > CHARLES SCHNABOLK P.E. COMMANDER ELECTRIC c o c¢ _ o v 1- o U +3 v > n _ •- ra 2 ¢ s 4 rag oO s o ¢ o I 48 � M ECU °� v a V) a a 7 3 3 �5 3 7 3 3 7 3 7 B(NAC) I I I c¢ ra t � + o �, cn Q c -5 - v o a ¢ � ¢ 1 ra a ¢ ra L L IO - L u ¢ o O CKT 1 0 0 0 o 0 0 0 0 0 0 --------------------- J ---------------J 7000 KENNEDY BLVD 42A 500 JOHNSON AVENUE > v 6d v - x +J L 2 +� 00 v ra U c ._ a - a o c� �' o - rn - i WP - 0 a ¢ M U- o : v v ? o c c '-" '-'° '-9 '-8 '-' '-6 '-5 '-4 '-3 '-2 '-' B(24V) GUTTENBERG, N.J. 07093 BOHEMIA N.Y. 11716 w - v rn a, I .. ,. U a !T a in _ ¢ = g > Ta f' i = o, in in J Q 0 o o o v o C -'-4 O fO ig Q c cn c o c o --------------------- O L <L L v LO N ° E na�i � _ � � wE c � c `ov '"° Uc B(24V) � ¢ � UU � I` � ¢ � = LO ' c o c o U o f U c s ci �t ¢ o L a _ 6 c o Q N o U c c U n c FLOOR NUMBER: FIRST FLOOR ow = o18c " wc o' v '0 a = v C) z O € ra € ro �' rn = ro U o = o ra v O ro = L . > E ,, fl U 'a � +� CL ro CL c o a E v = ai v a v a '� a'i m °' o ra v ¢ E ¢ E cn o I` E F(POWER) L to � � � � Q o � Q m o u.l +� rv'ov1 0 00 g' vcU � U _ � U Q o = �, o F- o:L1 Ur) ,i c ¢ O ra v m o = = U L rn - rn „ o o, //^\ /t/�, P TO DEDICATED 120VAC o � �u � r�o -m� � �-�� � � Ln �'¢ 'a � D � °' $ Ln E 0-Ln Ln Lo � � AWING TITLE: a) v o > ? _ _ 'c = c c +� _ '= RADIO COMMUNICATION FIRE ALARM SYSTEM �o rLo �, a, rLo v •rn V) a� = o o O ,= v `�° o '�° O o '>° o FAC TO CENTRAL STATION RISER DIAGRAM, LEGENDS, NOTES, PLOT PLAN F- p F- ro f- 0 in f- �n cn U a ro cn N a U u� H C7 I- g I- g I- cn F- g S stem Inputs A B C D E F G H I 3 K L M FIRST FLOOR FIRST FLOOR 1/O PROGRAMMING M AT R I X w N 1 Smoke Detector • • • • • N SEAL & SIGNATURE: i SWEET 1 OF 2 0 2 Duct Smoke Detector • • • • • 3 Manual Pull Station O • • O O 4 Thermal Detector • • • • • 5 Carbon Monoxide-Installed at CO • • • • • R I S E FR � I A G RA M o Source or Area Served b Source 6 Carbon Monoxide-Located in Other • • • AWN BY: C W. > o Location than CO Source Q • • • • fG � �C� CHECKED BY: T.M. Flame Detector 8 Sprinkler System Water Flow Switch ® • • O • ��` CJ J�Q V) or Pressure Switch 9 Sprinkler S stem Tam er Switch W0 E39139— 1 10 FACP and Sub-System AC Power Failure • • r,.)?r y SCALE: AS NOTED 11 FACP and Sub-System Low Battery Capacity • • iII,M. a 12 Open Circuit • • 13 Ground Fault • • °E, „ . '' t t CONTACT: D•. H ~ 14 Notification Appliance Circuit Short • • w 1� •15 Alert"Condition at ASDU Detection System Inputs O • ill C`/J � '�`A`"7 DRAWING NO: PAY Q o 16 FACP Power Failure O • • • • o D 17 FACP Power Failure • • jj o INPUT/OUTPUT MATRIX vv OFES .,,, "' 1 LICENSED BY THE N.Y.S. DEPARTMENT OF STATE NYS LICENSE #12000006636 ELEVATION DETAILS SCALE 1/8" = 1'-O" DROP CEILING TYPICAL UNLESS OTHERWISE NOTED. I C) RIGID STEEL DECK MER CONNECT AND PROTECT ACCESSIBLE, A PAVION COMPANY NON-COMBUSTIBLE SWITCHROOM, & PLENUM RETURN---__� POWER ROOM, GENERATOR DROP CEILING IN ROOM, 15'-0" 155 M CHAEL DRIVE OFFICE SPACE, COMPRESSOR- BATHROOMS 9,-0„ DEHYDRATOR SYOSSET, NEW YO R K 11791 (TYPICAL) ROOM (TYPICAL) 516.496.2322 VOICE 516.496.2848 FAX I I I COMPRESS / DYHRATOR CABLE VAULT ° JAN --------------------------------------------- --------- - N -4- o �RI '2-3 D-1 Lcoi AC Op OP Qp S REST l\ ,RIOp P D-47 D-45 D-43 OF ROOM D-20 D-21 ----------------------- ------------------------ Sic 0 I I P P 3 I i D-5 D-4 z Vol 2-7 Q F I I F D-42 c M-28 S D 46 OOP P OS p S FAC FACP 2-, o M-1 `� D-48 3 0 2-6 D-44 HALL D_3 S S ACC ,RI m • 2-5 O POP KB N D-2 z D-23 Op v OIEW O OIEW VIEW S TO R ° �- D-24 D-22 AC - 2 — O < + ° 206-01-02 FAN w 2 8 5 ESS MCC TOLL TRANSMISSI 2-� S SHUTDOWN STATUS MAP RM S o AIM CD ,RI FAN �SU O z , \AC SHUTDOWN w D-6 M-2 M-3 Op S P RL STATUS z Ln D-18 D-19 �S RT 0 AIM TRANE w AC - 1 > D-11 M-7 M-8 � 206-01-01 CD c� ❑ z SHUTDOWN CD w RL STATUS OIEw OIEw OIEw wS SU 0 AIM Q D-25 D-26 D-27 = D-9 M-4 M-5 o c CO r> z o N� Sg A 1-3 S CO �c + + FAN O + �'y D-10 M-6 O — o SHUTDOWN 2 9 0 L RL STATUS M'-2 Z 0 ELQ o M-14 M-15 W A M-11SHUTDOWN I o M-9 AIM UR/IR 0 RL CJ7 1-4 LLJ z S OIEW VIEW OS OS O i VIEW VIEW VIEW z D-32 D-31 D-30 D-29 D-28 'o` CONTR F O 1 w ��-10 ° 3 SB C w clf 12. 11 .2023 REVISED AS PER CONSTRUCTION CHANGES B Y O EOL STATUS CD w D 12 C0 w AIM RI AIM J 11 . 15.2022 ORIGINAL RELEASE A EM ERG POWER Lj M-16 M-12 DATE DESCRIPTION REVISION C PROJECT / TENANT INFORMATION BUILDING CWNER INFORMATION Z � i � w 0 LLJ ' M-13 Q w VERIZON STORE #32212 VERIZON � o - - ° 0 co 5 ESS sw + ° J 0 �sB A 74785 MAIN RD 1095 AVE OF THE AMERICAS o � 1-11 1-6 D-361Ew D-14"d�+ w ,_5 GREENPORT, N.Y. NEW YORK, N.Y. O O J � S VIEW VIEW VIEW 11944 10 0 3 6 c� D-33 D-34 D-35 O VIEW D-37 PROJECT ENGINEER / ARCHITECT SYSTEM DESIGNER / INSTALLING CONTRACTOR rol CHARLES SCHNABOLK, P.E. COMMANDER ELECTRIC m O 7000 KENNEDY BLVD 42A 500 JOHNSON AVENUE Q M-19 '-10 BATTERIES POWER D-38Ew GUTTENBERG, N.J. 07093 BOHEMIA, N.Y. 11716 F VACANT O O S ` 'RI EQUIP SUPPORT FLOOR NUMBER: FIRST FLOOR VIEW VIEW OIEW i�Sp C /� D-41 D-40 D-39 O O P P Q D-17 D-16 D-15 1-7 3 \ )5 CO LUNCH RM O DRAWING TITLE: FIRE ALARM SYSTEM °2 ° 1-9 1-8, \ LUNCH RM F -18 M FLOOR PLANS & ELEVATIONS I I • w � � o MAN ROAD SEAL & SIGNATURE: SHEET : 2 OF 2 w � o DRAWN BY: C.W. ` •`" Qcf) o �C�� � � , CHECKED BY: T.M. CD � ls"� � wo : E39139- 1 ME SCALE: Y c - FIRST FLOOR PLAN „ y�,�., AS NOTED Lij N FIRE ALARM SYSTEM SCALE:118°=1'-0° " ( CONTACT: DRAWING N0:w .,002 , 00 AFA )'ROOF_S�A��� - .,