Loading...
HomeMy WebLinkAbout50892-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50892 Date: 7/1/2024 Permission is hereby granted to: QJSG Pro erties LLC 333 Central Park W A t 106 New York, NY 10025 To: install generator as applied for. At premises located at: 38015 Route 25 Orient SCTM #473889 Sec/Block/Lot# 15.-2-15.7 Pursuant to application dated 5/10/2024 and approved by the Building Inspector. To expire on 12/31/2025. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 2' Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtowii Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only " y + " PERMIT NO. Building Inspector: Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. � � n Date:04/29/2024 OWNER(S) OF PROPERTY: Name:QJSG Properties LLC, Chad Gallant SCTM #1000-15-02-15.7 Project Address:38015 Main Road, Orient NY 11957 Phone#:646-734-3579 ]HI : Mailing Address:333 Central Park W, Apt 106, New York, NY 10025 CONTACT PERSON: Name:Gary Steinfeld/West Creek Builders Mailing Address:PO Box 256, New Suffolk, NY 11956 Phone#:631-334-9205 Email:gary@westcreekbuilders.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email CONTRACTOR INFORMATION: Name:West Creek Builders Mailing Address:PO Box 256, New Suffolk, NY 11956 Phone#:631-334-9205 Email:gary@westcreekbuilders.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Eil Other GENERATOR $10,000, Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existinguse ofproperty: Intended use ofproperty: Single Family Residential Single Family Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R80 I this property? ❑Yes RNo IF YES, PROVIDE A COPY. e Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Gary Steinfeld, West Creek Builders Authorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 20 Notary Public (Where the applicant is not the owner) Chad Gallant, QJSG Properties LLC 38015 Main Road, Orient NY, 11957 I, residing at do hereby authorize Gary Steinfeld, West Creek Builders to apply on my behalf to the Town of So old Building Department for approval as described herein. 0 h�l Owner's Signature Date Chad Gallant, QJSG Properties LLC Print Owner's Name 2 f BUILDING DEPARTMENT- Electrical Inspector a`� w TOWN OF SOUTHOLD "`� "� Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone 631 765-1802 - FAX 631 765-9502 , w fir, p ( ) ( ) " amesh southoldtownn . ov - seand southoldtownn v APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Z Company Name: e:7 ` fir + Electrician's Name: \S 'r o ,r' License No.: t/ -7 Z ,—&q ,��-�"`_Elec�e request an email Elec. Phone Noa,� q copy of Certificate of Compliance Elec. Address.:: . "� �, + o O JOB SITE INFORMATION (All Information Required) Name: �A-. T; Address: ® )iA (n/ Cross Street: Phone No.: Bldg.Permit #: �J� email: Tax Map District: 1000 1,5 Section: = o z Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Cleary): . . Square Footage: Circle All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate? YES NO Issued On Temp Information: (All information required) Service Sizer--11 Ph FJ3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[—]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 0 H Frame Pole Work done on Service? 0 Y EIN Additional Information: PAYMENT DUE WITH APPLICATION Application Data Cooling RDC2 Controller Radiator System 60 Hz 50 H Ambient temperature, °C ff) 45(113) Radiator system capacity,including engine,L(gal.) 21.3(5.6) Fie®9. so0 Engine jacket water flow,Lpm(gpm) 131 (34.6) 109(28.8) t: " Heat rejected to cooling water at rated o kW,dry exhaust,kW(Btu/min.) 48(2730) 44(2500) �� 8 2 Water pump type Centrifugal Fan diameter,mm(in.) qty.3 @ 356(14) Fan power requirements(powered by engine battery charging alternator) 12VDC, 18 amps each The RDC2 controller provides integrated control for the Operation Requirements generator set, KohlerO Model RXT transfer switch, Air Requirements 60 Hz 50 Hz programmable interface module(PIM), and load shed kit. Radiator-cooled cooling air, The RDC2 controller's 2-line LCD screen displays status m3/min. (scfm)t 3 62.2(2200) 62.2(2200) messages and system settings that are clear and easy to read, Air over engine,m /min.(cfm) 31.1 (1100) 31.1 (1100) Combustion air,m3/min.(cfm) 5.5(195) 4.6(162) even in direct sunlight or low light. z Air density=1.20 kg/m3(0.075 Ibm/ft3) RDC2 Controller Features Fuel Consumption* . Membrane keypad: Natural Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz o OFF,AUTO, and RUN pushbuttons 100% 24.8 (875) 21.5 (759) o Select and arrow buttons for access to system 75% 20.3 (717) 17.6 (622) configuration and adjustment menus 50% 14.5 (512) 12.6 (444) • LED indicators for OFF,AUTO, and RUN modes 25% 8.7 (307) 7.5 (266) • LED indicators for utility power and generator set source LP Gas,m3/hr..(cfh)at%load 60 Hz 50 Hz availability and ATS position (Model RXT transfer switch 100% 9.3 (329) 8.1 (285) required) 75% 6.5 (231) 7.1 (251) • LCD screen: 50% 4.9 (172) 4.2 (149 25% 3.1 (110) 2.7 (95) o Two lines x 16 characters per line Nominal Fuel Rating: Natural gas,37 MJ/m3(1000 Btu/ft3) o Backlit display with adjustable contrast for excellent LP Vapor,93 MJ/m3(2500 Btu)*I) visibility in all lighting conditions LP vapor conversion factors: • Scrolling system status display 8.58 ft.3=1 lb. o Generator set status 0.535 m3=1 kg. c Voltage and frequency 36.39 ft.3=1 gal. o Engine temperature o Oil pressure Sound Enclosure Features o Battery voltage • Sound-attenuating enclosure uses acoustic insulation that o Engine runtime hours meets UL 94 HF1 flammability classification and repels • Date and time displays moisture absorption. • Smart engine cooldown senses engine temperature • Internally mounted critical silencer. • Digital isochronous governor to maintain steady-state speed • Skid-mounted,aluminum construction with two removable at all loads access panels. • Digital voltage regulation: ±1.0%RMS no-load to full-load • Scratch-and corrosion-resistant KohlerD cashmere • Automatic start with programmed cranking cycle powder-baked finish. • Programmable exerciser can be set to start automatically on Sound Data any future day and time,and to run every week or every two weeks Model 48RCLC sound levels are 62 dB(A) during weekly engine • Exercise modes exercise and 63 dB(A) during normal operation. o Unloaded exercise with complete system diagnostics All sound levels are measured at a distance of 23 ft. (7 m)from o Unloaded full-speed exercise the generator set. Actual sound levels may vary based on o Loaded full-speed exercise(Model RXT ATS required) installation parameters. • Front-access mini USB connector for SiteTech- connection • Integral Ethernet connector for KohlerO OnCueO Plus • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-306 (48RCLC) 6/21 rs . KOHLER• LSdSJ.� Model: 48RCLC Multi-Fuel LPG/Natural Gas 09001 Standard Features LA KOHLEIRL • Kohler Co. provides one-source responsibility for the NATIONALLY REGISTERED generating system and accessories. • The generator set and its components are prototype-tested, factory-built, and production-tested. �• • _ _ • The generator set accepts rated load in one step. — —� • A standard 5-year/2000-hour limited warranty covers all systems and components. • Quick-ship(QS) models with selected features are available. See your Kohler distributor for details. • GFCI service outlet installed on the junction box. I • RDC2 Controller - c One digital controller manages both the generator set and i transfer switch functions (with optional Model RXT ATS). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to changing demand. The Kohler® Advantage o Digital voltage regulation protects your valuable • High Quality Power l electronics from harmonic distortion and unstable power Kohler generators provide advanced voltage and j quality. frequency regulation along with ultra-low levels of I • Engine Features harmonic distortion for excellent generator power quality to{ o Powerful and reliable Kohler 6.2L liquid-cooled engine protect your valuable electronics. o Electronic engine management system. • Extraordinary Reliability o Simple field conversion between natural gas and LP vapor Kohler is known for extraordinary reliability and fuels while maintaining emission certification. performance and backs that up with a 5-year/2000-hour e Innovative Cooling System limited warranty. o Electronically controlled fan speeds minimize generator • Aluminum Enclosure set sound signature. Attractive aluminum enclosure allows installation as close as 18 inches from your home or small business. • Approved for stationary standby applications in locations Optional 291 kph (181 mph)wind-load-rated enclosure served by a reliable utility source. door kit is available for field installation. • Certifications • Fast Response o The 60 Hz generator set engine is certified by the Kohler's Fast-Response@ X excitation system delivers Environmental Protection Agency(EPA)to conform to the excellent voltage response and short-circuit capability New Source Performance Standard (NSPS).for stationary using a rare-earth permanent magnet(PM)-excited spark-ignited emissions. alternator. o cUL/UL listing,CSA certification standard are available. • Quiet Operation o Accepted by the Massachusetts Board of Registration of Kohler home generators provide quiet, neighborhood- Plumbers and Gas Fitters. friendly performance. o Meets NFPA 37 requirements for 18 in. offset for installation. Generator Set Ratings Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kW/kVA' Amps kW/kVA Amps 120/240 1 60 44/44 184 44/44 184 120/208 3 60 48/60 167 50/62 173 4P7BX 127/220 3 60 48/60 158 50/62 163 120/240 3 60 48/60 145 50/62 150 277/480 3 60 48/60 73 50/62 75 4Q7BX 120/240 1 60 48/48 200 48/48 200 * 50 Hz options available.Contact your Customer Service representative. RATINGS: All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings., Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage.There is no overload capability for this rating. Ratings are in accordance with ISO-8528-1 and ISO-3046-1.Obtain technical information bulletin TIB-101 for ratings guidelines,complete ratings definitions,and site condition derates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Availability is sugect to change without notice. Contact your local Kohler generator distributor for availability. G4-306 (48RCLC) 621 A Alternator Specifications Specifications Alternator • The unique Fast-Response@ X excitation system delivers Manufacturer Kohler excellent voltage response and short-circuit capability using a Type 4-Pole,Rotating Field rare-earth, permanent magnet(PM)-excited alternator. Exciter type Brushless,Rare-Earth • Brushless, rotating-field alternator. Permanent Magnet • NEMA MG1, IEEE,and ANSI standards compliance for Leads:quantity,type temperature rise and motor starting. 4Q7BX 4,120/240 4P7BX 12,Reconnectable • Sustained short-circuit current of up to 300%of the rated Voltage regulator Solid State,Volts/Hz Current for up to 10 seconds. Insulation: NEMA MG1 • Sustained short-circuit current enabling downstream circuit Material Class H Temperature rise 130°C,Standby breakers to trip without collapsing the alternator field. Bearing:quantity,type 1,Sealed • Self-ventilated and dripproof Construction. Coupling Flexible Disc Amortisseur windings Full • Windings are vacuum-impregnated with epoxy varnish for Voltage regulation,no-load to full-load :t 1.0%RMS dependability and long life. Unbalanced load capability 100%of Rated Standby a Superior voltage waveform from a two-thirds itch stator and Current P 9 P One-step load acceptance 100%of Rating skewed rotor. Peak motor starting kVA: (35%dip for voltages below) • Total harmonic distortion (THD)from no load to full load with 480 V,400 V 4P7BX(12 lead) 180(60 Hz), 136(50 Hz) a linear load is less than 4%. 240 V 4Q7BX(4 lead) 113(60 Hz) Application Data Engine Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type KG6208 6.21- Exhaust flow at rated kW,m3/min.(cfm) 16.4(580) 13.6(480) Natural Aspiration Exhaust temperature at rated kW,dry Cylinder arrangement V-8 exhaust, °C(°F) 649(1200) Rated rpm 1800 1500 Maximum allowable back pressure, Displacement,L(cu.in.) 6.2(378) kPa(in.Hg) 10.2(3.0) Bore and stroke,mm(in.) 101.6 x 95.25(4.00 x 3.75) Exhaust outlet size at engine hookup, Compression ratio 10.5:1 mm(in.) 76(3.0)OD Max.power at rated rpm,kW(HP) 77.0(103) 64.3(86) Cylinder head material Cast Aluminum Fuel Piston type and material High Silicon Aluminum Fuel System Crankshaft material Cast Iron Fuel type LP Gas or Natural Gas Valve(exhaust)material Forged Steel Governor type Electronic Fuel supply line inlet 1 in.NPT Frequency regulation,no-load to full-load Isochronous Natural gas fuel supply pressure, Frequency regulation,steady state :t1.0% kPa(in.H2O) 1.2-2.7(5-11) Frequency Fixed LPG vapor withdrawal fuel supply Air cleaner type Dry pressure,kPa(in.H2O) 1.2-2.7(5-11) Fuel Composition Limits* Nat.Gas LP Gas Engine Electrical Methane,%by volume 92 min. — Engine Electrical System Ethane,%by volume 4.5 max. — Ignition system Electronic Propane,%by volume 1.0 max. 87 min. Propene,%by volume 0.1 max. 5.0 max. Battery charging alternator: C4 and higher,%by volume 0.3 max. 2.5 max. Ground(negative/positive) Negative Sulfur,ppm mass 25 max. Volts(DC) 12 Lower heatin value, Ampere rating 130 MJ/m3(Btu/ft ),min. 33.2(890) 84.2(2260) Starter motor rated voltage(DC) 12 * Fuels with other compositions may be acceptable. If your fuel is Battery,recommended cold cranking outside the listed specifications,contact your local distributor for amps(CCA): further analysis and advice. Qty.,rating for-18°C(0°F) One,630 Battery voltage(DC) 12 Lubrication Battery group size 24 Lubricating System Type Full Pressure Oil pan capacity,L(qt.) 5.7(6.0) Oil pan capacity with filter,L(qt.) 7.1 (7.5) Oil filter:quantity,type 1,Cartridge G4-306 (48RCLC) 6/21 i J j Application Data Cooling RDC2 Controller Radiator System 60 Hz 50 Hz , Ambient temperature,°C ff) 45(113) Radiator system capacity,including engine,L(gal.) 21.3(5.6) F�eg9e 82 11 O Engine jacket water flow,Lpm(gpm) 131 (34.6) 109(28.8) p O O Heat rejected to cooling water at rated �Do D kW,dry exhaust,kW(Btu/min.) 48(2730) 44(2500) r 1 O O O O Water pump type Centrifugal ® w A Fan diameter,mm(in.) qty.3 @ 356(14) Fan power requirements(powered by i engine battery charging alternator) 12VDC,18 amps each The RDC2 controller provides integrated control for the Operation Requirements i generator set, Kohler@ Model RXT transfer switch, Air Requirements 60 Hz 50 Hz 1 programmable interface module (PIM),and load shed kit. Radiator-cooled cooling air, I The RDC2 controller's 2-line LCD screen displays status m3/min.(scfm); 3 s2.2(2200) 62.2(2200) messages and system settings that are clear and easy to read, Air over engine,m /min. (cfm) 31.1 (1100) 31.1 (1100) Combustion air,m%in. (cfm) 5.5(195) 4.6(162)� even in direct sunlight or low light. # Air density=1.20 kg/m3(0.075 Ibm/ft3) RDC2 Controller Features I Fuel Consumption* • Membrane keypad: Natural Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz o OFF,AUTO, and RUN pushbuttons 100% 24.8 (875) 21.5 (759) o Select and arrow buttons for access to system 75% 20.3 (717) 17.6 (622) configuration and adjustment menus 50% 14.5 (512) 12.6 (444) : LED indicators for OFF,AUTO, and RUN modes 25% 8.7 (307) 7.5 '(266) , LED indicators for utility power and generator set source LP Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz ! availability and ATS position (Model RXT transfer switch 100% 9.3 (329) 8.1 .(285) required) 75% 6.5 (231) 7.1 (251) ; LCD screen: 50% 4.9 172 4.2 (149 25% 3.1 (110) 2.7 (9'5) o Two lines x 16 characters per line 4- Nominal Fuel Rating: Natural gas,37 MJ/m3(1000 Btu/ft3) o Backlit display with adjustable contrast for excellent LP Vapor,93 MJ/m3(2500 Btu/ft3) visibility in all lighting conditions LP vapor conversion factors: • Scrolling system status display 8.58 ft.3=1 lb. o Generator set status 0.535 m3=1 kg. ? o Voltage and frequency 36.39 ft.3=1 gal. o Engine temperature I o Oil pressure Sound Enclosure Features j o Battery voltage • Sound-attenuating enclosure uses acoustic insulation that, o Engine runtime hours meets UL 94 HF1 flammability classification and repels o Date and time displays moisture absorption. • Smart engine cooldown senses engine temperature • Internally mounted critical silencer. j • Digital isochronous governor to maintain steady-state.speed • Skid-mounted, aluminum construction with two removable! at all loads access panels. • Digital voltage regulation: ±1.0% RMS no-load to full-load • Scratch-and corrosion-resistant Kohler@ cashmere • Automatic start with programmed cranking cycle powder-baked finish. • Programmable exerciser can be set to start automatically on Sound Data any future day and time, and to run every week or every two weeks Model 48RCLC sound levels are 62 dB(A) during weekly engine • Exercise modes exercise and 63 dB(A) during normal operation. o Unloaded exercise with complete system diagnostics All sound levels are measured at a distance of 23 ft. (7 m)from o Unloaded full-speed exercise the generator set. Actual sound levels may vary based on o Loaded full-speed exercise (Model RXT ATS required) installation parameters. • Front-access mini USB connector for SiteTech- connection • Integral Ethernet connector for KohlerG,OnCueD Plus • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-306 (48RCLC) 6/21 KOHLER® PhoneKOHL 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Additional RDC2 Controller Features Available Options(continued) • Diagnostic messages Enclosure Option o Displays diagnostic messages for the engine,generator, ❑ 291 kph(181 mph)wind load rated enclosure Model RXT transfer switch, programmable interface Starting Aids§ module(PIM),and load shed kit ❑ Block Heater, 120 V o Over 70 diagnostic messages can be displayed ❑ Block Heater,240 V • Maintenance reminders § Recommended for ambient temperatures below 0°C(32°F) • System settings Controller Accessories o System voltage,frequency, and phase ❑ Lockable Emergency Stop(lockout/tagout) o Voltage adjustment ❑ Programmable Interface Module(PIM) o Measurement system, English or metric (provides 2 digital inputs and 6 relay outputs) • ATS status(Model RXT ATS required) Automatic Transfer Switches and Accessories o Source availability ❑ Model RXT Automatic Transfer Switch o ATS position (normal/utility or emergency/generator) ❑ Model RXT Automatic Transfer Switch with combined interface/ o Source voltage and frequency load management board • ATS control (Model RXT ATS required) ❑ Model RDT Automatic Transfer Switch o Source voltage and frequency settings ❑ Load shed kit for RDT or RXT ❑ Power relay modules(use up to 4 relay modules for o Engine start time delay each load management device) o Transfer time delays ❑ Other Kohler@ ATS o Fixed pickup and dropout settings Miscellaneous o Voltage calibration ❑ Rated Power Factor Testing • Programmable Interface Module(PIM)status displays ❑ Maintenance kit(includes air filter,oil,oil filter,and spark plugs) o Input status (active/inactive) Literature o Output status (active/inactive) ❑ General Maintenance Literature Kit • Load Control menus ❑ Overhaul Literature Kit o Load status ❑ Production Literature Kit o Test function Warranty Generator Set Standard Features ❑ Extended 5-Year/2000 Hour Comprehensive Limited Warranty ❑ Extended 10-Year/2000 Hour Comprehensive Limited Warranty • Aluminum sound enclosure with enclosed silencer • Battery rack and cables Dimensions and Weights • cUL/UL 2200 listed, CSA certified Overall Size,L x W x H,mm(in.): 2280 x 836 x 1182 • Electronic, isochronous governor (89.8 x 32.9 x 46.5) • Engine-generator set is designed and manufactured in Shipping Weight,wet,kg(lb.): 767(1690) facilities Certified t0 ISO:9001. Weight includes generator set with engine fluids and 4Q7BX alternator, • Flexible fuel line sound enclosure,and silencer. • Gas fuel system(includes fuel mixer,electronic secondary gas regulator,two gas solenoid valves, and flexible fuel line between the engine and the skid-mounted fuel system components) H • GFCI service outlet(120/240 V)for customer connections • Integral vibration isolation • Line circuit breaker • NEC prime mover shutdown switch �0 — W­6� L • Oil drain extension NOTE:This drawing is provided for reference only and should not be • OnCue@ Plus Generator Management System for remote used for planning installation. Contact your local distributor for more monitoring(see specification sheet G6-140) detailed information. • Operation and installation literature DISTRIBUTED BY: • RDC2 controller with built-in battery charger • Standard 5-year/2000-hour limited warranty Available Options Electrical System ❑ Battery ❑ Battery Heater ❑ OnCueO Plus Wireless Radio Kit ©2021 Kohler Co. All rights reserved. G4-306 (48RCLC) 6121