Loading...
HomeMy WebLinkAbout50889-Z TOWN OF SOUTHOLD w' BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY 10 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50889 Date: 7/1/2024 Permission is hereby granted to: Donson, Nathaniel 898 Helen St Teaneck, NJ 07666 To; install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 1687 Rocky Point Rd, East Marion SCTM #473889 Sec/Block/Lot# 30.-3-11 Pursuant to application dated 5/9/2024 and approved by the Building Inspector.. To expire on 12/31/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector � xcrr,ra , TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 litt s:H w .soutl oldt wrnn . o Date Received APPLICATION FOR BUILDING PERMIT .* E For Office Use Only PERMIT NO, ✓ Building Inspector. - ?t M Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an '° Owner's Authorization form(Page 2)shall be completed. Date: 5-1 a aq OWNER(S)OF PROPERTY: Name:Nathaniel Donson SCTM#1000-30-3-11 Project Address:1687 Rocky Point Road, East Marion, NY 11939 Phone#:201-835-9969 Email:nathanieldonson345@gmail.com Mailing Address: 1687 Rocky Point Road, East Marion, NY 11939 CONTACT PERSON: Name: Evelyn Polvere/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 ext 346 Email:permitting@sunation.com DESIGN PROFESSIONAL INFORMATION: Name: William Fisher Mailing Address:509 Sayville Blvd, Sayville, NY 11782 Phone#:631-786-4419 Email:bill@fisher-ny.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems � Mailing Address:171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email permitting@sunation.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ 6 Will the lot be re-graded? ❑Yes No Will excess fill be removed from premises? ❑Yes RNo PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes WNo IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.4S of the New York State Penal Law. Application Submitted By(print name) Scott Maskln BAuthorized Agent ❑Owner Signature of Applicant: Date: 5 la I a STATE OF NEW YORK) SS: COUNTY OF Suffolk ), Scott Maskln being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Qr day of p' , 20 a ± ��� ,� Notary Public LYNN VITA Notary Public, State of New"'6 Registration #01V15068399 PROPERTY OWNER AUTHORIZATION Qualified sn Suffolk County (Where the applicant is not the owner) My Commission Expires Oct.28, Nathaniel Donson residing at 1687 Rocky Point Road East Marion, NY do hereby authorize Scott Maskin to apply on my aIf t t Town of Southold Building Department for approval as described herein. Owner's Signature Date Nathaniel Donson Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector TOWN OFSOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 w .'µ.r Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@southoldtownny.gov sea nd southoldtownnygov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date; Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: ermittin sunation.com Address: 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Nathaniel Donson Address: 1687 Rock Point Road East Marion NY 11939 Cross Street: Phone No.: 201-835-9969 Bldg.Permit#: email: nathanieldonson345@gmail.com Tax Map District: 1000 Section: 30 Block: 3 Lot: 11 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A, #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information:. PAYMENT DIE WITH APPLICATION Request for Inspection FormAs NYSIF PO Box 66699,Albany,NY 12206 New York State Insurance Fund nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE nnnnnn 75311881E ll, GCG RISK MANAGEMENT INC AN NFP COMPANY 100 CHURCH STREET-SUITE 810 NEW YORK NY 10007 SCAN TO VALIDATE AND SUBSCRIBE ...... POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 ......... POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 670-2 43689 01/01/2024 TO 01/01/2025 12/11/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS' COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND 4 DIRECTOR,I(SURANCE FUND UNDERWRITING VALIDATION NUMBER: 601025760 IDpgII�IIinnHillnotnuimmlnNia1rniinninninuan11011gplI��I��p IIII 000000000001 22055844 III Fonn WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-216067021 U-263 64 [00000000000122055844][0001-0000216067021[##23[16282-oal[Cer NoPCERT_Ll[01-00001] y AN O workers CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured SUNATION SOLAR SYSTEMS 631-750-9454 171 REMINGTON BOULEVARD RONKONKOMA,NY 11779 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 753118816 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"1 a" PO Box 1179 DBL631187 Southold, NY 11971 3c.Policy effective period 10/01/2022 to 09/30/2024 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,)cerlity that I am an authon ed ipresentative or licensed agent of the wn urance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 9/26/2023 By lr (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier Telephone Number 516-829-8100 Name and Title Richard White., Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 413,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed BY ................. _._...... _.�, (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title _...._. .......... Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) I�j�j I I�111111111111111111111111111 DB 120.1 (12-21) �,,,,,0 DATE(MM/DDIYYYY) ,I""#w C40�'#�L..+r' CERTIFICATE OF LIABILITY INSURANCE 01/25/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endomement(s). PRODUCER CONTACTShelby Glerdal I NAME;: Christensen Group PHDN Fes,, (952)653-1000 AIC Na: (952)653-1100 9855 West 78th Street,Ste 100 4oDRC's sglerdalt chrislensengroUp.cOtts INSURERS)AFFORDING COVERAGE NAIL# Eden Prairie MN 55344 INsuRERA: James River Insurance Company 12203 INSURED wsuRER e: Crum&Forster Specialty Insurance Company 44520 SUNation Solar Systems,Inc. INSURER C: Ascot Insurance Company 23752 171 Remington Blvd INSURER D: INSURER E: Ronkonkoma NY 11779 INSURERF: COVERAGES CERTIFICATE NUMBER: 12/01/23-24 91UNatcon REVISION NUMBER.: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER /D MMD MMTQ P LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE ',$ 1,000,000 CLAIMS-MADE �OCCUR PREMISES.Ea occurrence $ 50,000 MED EXP(Any one person) $ Excluded A P0000000282 12/01/2023 12/01/2024 PERSONAL&ADV INJURY $ 1,000,000 GEN'LAGGREGATE LIMIT APPLIES PER'. GENERALAGGREGATE $ 2,000,000 POLICY LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER' $ AUTOMOBILE LIABILITY C'OMBNN'ED 'INGLE[Wrr $ 1,000,000 :Ea awdaru "" ANYAUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED 133-756069-5 12/14/2023 12/01/2024 BODILY INJURY(Per accident) $ AUTOS ONLY E AUTOS HIRED NON-OWNED PROPERTYDAMAGE $ AUTOS ONLY AUTOS ONLYId ................... Per acc"derak X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 3,000,000 A EXCESS LIAR CLAIMS-MADE P0000000283 12/01/2023 12/01/2024 AGGREGATE $ 3,000,000 DED RETENTION$ O $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY YIN STATUTE ER ANY PROPRIETORIPARTNER/EXECUTIVE NIA E,L,.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? (Mandatory in NH) E.L,.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Newly Built/Acqur Bldgs $500,000 Property/Builders Risk C IMMA2310001919-01 12/01/2023 12/01/2024 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 54375 Main Road AUTHORIZED REPRESENTATIVE Southold NY 11971 ,rµ ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD Suffolk County Dept. of w Labor, Licensing & Consumer Affairs HOME IMPROVEMENT LICENSE Name SCOTT MASKIN m Business Name SUNation Solar Systems Inc This certifies that the bearer is duly licensed License Number H-44104 by the County of suffolk Issued: 03/06/2008 W�nt., -r. Roge-ry Expires: 03/01/2026 Commissioner IIIIII Suffolk County Dept. of Labor, Licensing & Consumer Affairs MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN Business Name SUNATION SOLAR SYSTEMS INC This certifies that the bearer is duly licensed License Number ME-33412 by the County of suffolk Issued: 06/24/2003 Roi Drago- Expires: 06/01/2025 Commissioner PLAN KEY ®"UTILIT PROPOSED RESIDENTIAL Q-SERVI CCEE D DISCONNECT ISC PV1-0 COVER SHEET SUPPLYCONNECTION A1_1 PARTIAL ROOF PLAN AUTOMATIC TRANSFER SWITCH 560 PHOTOVOLTAIC SYSTEM Al-4 ROOF ACCESS PLAN R"GAS METER (EXT) / I\ 0 S1-1 STRUCTURE M-MAINSERVICEPANEL � IQ UNDERGROUND / M-SUB PANEL DS -_ (4)PROPOSED PV MODULES SERVICE (ExT) SUNATION SOLAR SYSTEMS NYSERDA 4355 E1-1 ONE-LINE DIAGRAM - 171 REMINGTON BOULEVARD INSTALLER S -WIRELESSROIJTER MSP ACCESS ! RONKONKOMA, NEW YORK 11779 NUMBER E2-1 PV LABELS - �- ®-INVERTER G1-1 PV PHOTOS z Q-ENPHASE IO COMBINER j Donson Residence ©-PANEL PHOTOVOLTAIC (e) glq / 1687 Rocky Point Road, East Marion, NY 11939 -ELECTRIC VEHICLE CHARGER ~ ~ ®-ENPHASE ENVOY �RWF ALBS Drawn By: J. DellaRocca-05/01/2024 IR-SENSE CONSUMPTION MONITOR ` I / ®-AC DISCONNECT IACCESS" �( LJr ,VT�� -TESTA GATEWAY �, I , 36 .. - ®-TESLAPOWERWALL \,gym •�7� �0 -ENPHASE K]SYSTEM CONTROLLER ROOF ACCESS M-ENPHASE 10 LOAD CONTROLLER -�- (11)PROPOSED PV MODULES -ENPHASE IO ID BATTERY ®-ENPHASE 101 BATTERYROOF n 1 ! ®-GENERATION PANEL // IACCE96 I \ \ I `�Q� 4,1 0•������ \ K -BACKEU UM LOADS CENTER '. r -18"-VENTILATION [ �- ©-VENT PIPE -18"-VENTILATION ! I FRONT OF HOUSE W - "•-EXTERIOR LOCATION -_- -— Z Z ! FACING STREET OR IST FLOOR LOCATION \ RooF I / < g a Building g Review Note BASEMENT LOCATION A Z �I Town building examiner has received the enclosed document for minimum acceptable ' - Ii > W plan submittal requirements of the town as specified in the building and/or Residential GARAGE LOCATION Code of the State of New York. This review does not guarantee compliance with that 9 code, that responsibility is guaranteed under the seal and signature of the New York PROPOSED PV SYSTEM (3)Paoroseo PV MODULES State licensed design professional of record. That seal and signature has been interpreted as an attestation that,to the best of the licensee's belief and information e/Qt 37 REC420AA Pure 2 �' the work in this document is: Module Type y ( ) Accurate !� � • Conforms with governing codes applicable at the time of submission Module Dimension: 73.4"x 40.9"x 1.2" • Conforms with reasonable standards of practice and with view to the (19)PROPOSED PV MODULES safeguarding of life,health,property and public welfare is the responsibility of the Module Weight/PSF: 47.6 Ibs/2.27969348659004 PSF i licensee. Micro Inverter: (37)Enphase IQ8A-72-2-US ACCESS '- Structural Statement System DC Rating: 15.54 kW • The existing structure is adequate to support the new loads imposed by the System AC Rating: 12.876 kW/AC photovoltaic module system including uplift and shear. The existing rafter sizes and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. Aurora Estimated AC Production: 14,623 kWh/yr PV Notes 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be provided where necessary. An in depth description of each applicable code reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more N than 6-inches above the surface of the roof. 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and inspection. FULL HOUSE ROOF PLAN SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PV1 w COVER PAGE JOB# 24146 I REVISION # N/A SUNATION :.N REVISED BY N/A �E OF �FIY r- --m-sYz LLJ • 4 �,o �0.07 ? ------------ w o -2yZ a: ZROOF4SUNATION SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 HOUSE ROOF 2 r-7y -r 1V2 rw NYSALLE 4355 INSTALLER 3,.' • 3, • • • V NUMBER CIRCUIT 3 „ ( JOB NUMBER \ CC 24146 r • „Y.W �' =rg • CIRCUIT 1 CIRCUIT 4 rn RIDGE f W Z N C t (5 Z 6 O Nip\ m /� • LL H ROOF 1 Q m v-�N HOUSE ! � N a U ROOF 3 X j' C ¢ IL co Z c 0 0 CIRCUIT 2 / /% j \ y 0 .5 m GUTTER o m 2Co 0 � n R-R.-YXe• Roof# Roof Description Modules Azimuth Tilt Pitch Attachment Spacing: Portrait Attachment Spacing:Landscape Interior Edge Corner Interior Edge Corner 1 FOH East Roof 11 1050 310 8.3/12 48" 32" 16" 64" 48" 64" 1/8" = 1'-0" 2 BOH West Roof 19 2850 300 8/12 48" 32" 16" 64" 48" 64" 3 BOH Lower South Roof 3 1950 140 3.7/12 32" 16" 16" 64" 48" 32" Al 1 4 FOH Lower East Roof 4 1 105° 21° 5.6/12 48" 32" 16" 64" 64" 48" PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS (NY) R324.6 Roof access and pathways. Roof access, pathways and setback requirements shall be provided in accordance with Sections `Q' ��Om G• �0 R324.61 through R324.6.2.1. Access and minimum spacing shall be Crj required to provide emergency access to the roof,to provide pathways to specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. Exceptions: o �0•07465g _ 1. Detached, nonhabitable structures, including but not limited to detached garages, parking shade structures, carports, solar trellises and similar structures, shall not be required to provide roof access. % 2. Roof access, pathways and setbacks need to be provided (EXT) i where the building official has determined that rooftop O iQ j /�UNDERGROUND - (EXT operations will not be employed. (4)PROPOSED PV MODULES i SERVICE ) 3. These requirements shall not apply to roofs with slopes of two MSP ACCESS v .SLO-II^TION units vertical in 12 units horizontal(17 percent slope)or less a T SUNation Solar Systems [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate ) fG) Z'z 171 Remington Blvd. roof planes from lowest roof edge to ridge and not less than 36 inches / o i 4 Ronkonkoma.New York 11779 (914 mm)wide, shall be provided on all buildings. Not fewer than one 5!�! (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. Ws For each roof plane with a photovoltaic array, a pathway not less than ` :'''I - 36 inches (914 mm) wide shall be provided from the lowest roof edge ACCES NYSERDA 4355 FKOF INSTALLER to the ridge on thee same roof plane as the photovoltaic array, on an NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. - Pathways shall be over areas capable of supporting fire fighters JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal ROOF obstructions such as vent pipes, conduit, or mechanical equipment. noss - / (11)PROPOSED PV MODULES 24146 Pathways on opposing roof slopes shall not be located along the same l 1 plane as the truss, rafter, or other such framing system that supports the pathway. ACCESS 7I Exception: 18'-VENTILATION -18'-VENTILATION < �f \ I - rn 1. Access pathways shall not be required on roof slopes containing Z z FACING STREET FRONT OF HOUSE v photovoltaic modules, panels, or an array where the opposing ` OR t. ° ° DRIVEWAY } cli or adjacent roof slope is an access roof. ROOF J J Z 0 \ ACCESSIi F H / Z z Z C ^O . / W W O O Access Roof-A roof surface that: i I ' ' Q c o m a / a� m 1. Can be accessed from the ground by the fire service. (3)PROPOSED PV MODULES �l u 2. Is capable of providing fire service access to the ridge or peak 0 O Er m � of an opposing or adjacent roof surface that contains A\ Z o o a ` N o photovoltaic modules, panels,or an array. ! — � Er 3. Is relatively free of vents,skylights,conduits,mechanical 0 o equipment and other such obstructions. t1s)PROPOSED PV MODULES N a m 4. Does not contain photovoltaic modules, panels or an array, or isFOOF o a single ridge roof where the maximum edge to edge width of ACCESS the photovoltaic panel system does not exceed 33 percent of 00 the ridge length. c� [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be T located less than 18 inches(457 mm)from a horizontal ridge. [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches (914 mm)wide shall be provided to the emergency escape and rescue opening. 3/32" = V-0" A1 =4 ROOF ACCESS PLAN Typical Attachment Method �O SNAP'N'RACK ULTRA RAIL RIDGE--\ RIDGE LFOOT AND RAIL ASSEMBLY PHOTOVOLTAIC 20'-11.5" PHOTOVOLTAIC 10'-5.5" SNAP'N'RACK MODULE �� MODULE ALUMINUM FLASHING 3/4"MODULE SPACING 3/4"MODULE SPACING BETWEEN ROWS AND �_ BETWEEN ROWS AND �� i O SUNATION COLUMNS(TYP.) COLUMNS(TYP.) �� C, ) SUNation Solar Systems RAIL 171 Remington Blvd. RAIL (1)5/16"X 5"0 LAG BOLT (1)LAYER COMPOSITE Ronkonkoma,New York 11779 WITH FLAT WASHER SHINGLE (631)-750-9454 RAFTER RAFTER SNAP'N'RACK BASE PLATE NYSERDA 2"X 8"/16"C.C. INSTAALLELLE \ 2"X 4"/16"O.C. FASTENED TO RAFTER I INSTALLER 435%5NUMBER JOB NUMBER 24146 PLYWOOD DECKING, SOFFR SOFFR EXTERIOR EXTERIOR i WALL WALL WOOD FRAMING . (� 1 s'-2° —I (TYP.)6'_All _ ATTACHMENT TYPE APPLIED TO-ROOF"TYP" ROOF SECTION (TYP.) -ROOF"1,2,4" ROOF SECTION (TYP.) - ROOF"3" SCALE: N.T.S. SCALE: N.T.S. rn } CV Z N 0 O O � ZZ U cCZ O SOLAR MODULE FRAME G NOTE:3/4"SPACING Q) CZ BETWEEN MODULE ROWS Q U U Roof# Rafter Size/Spacing Max Span Material Layers Sheathing eee e eee AND COLUMNS. cz c, o °06°0 oc Q) w o Cc 1 2"x 8"/16"O.C. 14'-2.5" Composite Shingles PI o o ° 5.5• LL Cr P g 1 Plywood °o° ° HEIGHT ADJUSTABLE LL L-FOOT(TYP.) Z C: CZ 2 2"x 8"/16"O.C. 14'-3.5" Composite Shingles 1 Plywood END CLAMP LU �° 0 (TYP.) t 3 2"x 4" /16"O.C. 8'-9" Composite Shingles 1 Plywood N O _c <� ° SNAP'N'RACK Q (] 4 2"x 8"/16"O.C. 18'-2" Composite Shingles 1 Plywood V° 0 6RA°' n RAIL HEIGHT OFF OF U ?) ROOF SURFACE O CZ y FIT MINI 2 MP-) 00 Typical Module PEST WRAP CUT co AWAYFOR T Side Profile CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL GROUND SNOW TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY TEMPERATURE UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX TEMPERATURE LOAD SPEED(MPH.) EFFECTS SPECIAL WIND ZONE ZONE WEATHERING FROST LINE DEPTH TERMITE REQUIRED S 1 1 20 PSF 140 B NO 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE qF Nc <va 010746 Enphase A/C Branch Circuit(typ.) UTILITY SERVICE Enphase Microinverter(typ.) —� -_^z Existing L COMBINER Account E#-961i4960603 Mity Meter SUNNTION Module J-Box(typ.) PANEL Meter#-98438201 120/240V SUNation Solar Systems �'✓ SUPPLY SIDE CONNECTION 171 Remington Blvd. Ronkonkoma.New York 11779 (631)-750-9454 PV Module (bP) NYSERLE 4315 5 To R MOON \ INSTALLER EGC Attached ail (tYP•) J NUMBER MAIN ENPHASE GATEWAY JOB NUMBER INS IoWs.m "",on 5 L 2P20A 2�1`1A 24146 Circuit#1 CONDUIT AND CONDUCTOR SCHEDULE ENPHASE BRANCH CIRCUIT*1 — ! 2P20A Circuit#2 TAG CONDUCTOR CONDUIT RUN ENPHASE BRANCH CIRCUIT#2 ^ I ^ 2120A ENPHASE BRANCH CIRCUIT#3 Circuit#3 1 70A 1 TYPE GAUGE QUANTITY TYPE SIZE LENGTH l��J MAIN ENPHASE BRANCH CIRCUIT#4 CvcurtM4 1 Enphase Q-Cable 12 8 N/A N/A 15' rn I;� 2 Type NM 10 8 N/A N/A 30' EGC G G Ca MAIN r � 3 HWN-2 10 8 PVC SCH.80 1.25" 15' 2 3 ENPHASE A/C SERVICE GC 10 1 PVC SCH.80 1.25" 15' ROOF ATTIC EXTERIOR 10 COMBINER DISCONNECT PANEL N I SERVICE Z N RATED 4 HWN-2 4 3 PVC SCH.80 1.25" 10' 4 ENCLOSURE 6 T MIN.60A 0 O GC 8 1 PVC SCH.80 1.25" 10' MIN.22k AIC Z N � C) 5 HWN-2 4 3 PVC SCH.80 1.25" 10' — :2 6 EC 4 1 N/A N/A 10' EXTERIOR BUILDING ' DISCONNECTING MEANS Q -� U GROUNDING ELECTRODE LU �O ? O O N H U) Circuit# PV Module Oty. Micro-Inverter Qty. Maximum AC Operating Current (n c -71 0 1 REC420AA Pure 2 11 Enphase IQ8A-72-2-US 11 15.95 A d m 2 REC420AA Pure 2 11 Enphase IQ8A-72-2-US 11 15.95 A o 3 REC420AA Pure 2 8 Enphase IQ8A-72-2-US 8 11.6 A c 00 4 REC420AA Pure 2 7 Enphase I08A-72-2-US 7 10.15 A T I Maximum AC Operating Current(Total) 53.65 A Elml : ONE-LINE DIAGRAM I PHOTOVOLTAIC AC DIS- a LABEL LOCATION: LABEL LOCATION: ,MAXIMUM AC•' SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE ANDServiceDisconnectMAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE �Q';\ti�m OCURRENT• CURRENT VALUES ON DISCONNECT LABEL. DISCONNECT IF APPLICABLE. N� •NEC 2017 690.54/NEC 2017 690.13(B) NEC 2017 705.10 Second Disconnect WAR -. - Meter Pan ��` " ELECTRIC SHOCK HAZARD NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO DO NOT TOUCH TERMINALS THE BUILDING MAIN SERVICE DISCONNECT. TERMINALS ON BOTH THE LINE AND Primary Service LOAD SIDES MAY BE ENERGIZED This building is equipped with an IN THE OPEN POSITION LocatedServicePanelInterconnected Electric Power �l SUNATION Production Source J PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE WHENEVER THEY ARE EXPOED TO SUNLIGHT 1 1 1 1 SUNation Solar Systems Source Type 171 Remington Blvd. Solar Photovoltaic Ronkonkoma,New York 11779 (631)-750-9454 Disconnect is Located inienor -asement Garage LH Sid!_ IN S RDA INSTALLER 4355 Front Rear_ LH Side INSTALLER ?�+Side-_ Other Location. NUMBER SUNation Solar Systerns SOLAR SYSTEM EQUIPPED JOB NUMBER 631-750-9454 WITH RAPID SHUTDOWN www.sunation.ccm TURN RAPID SHUTDOWN 24146 SWITCH TO THE PH • • • SYS "OFF'POSITION TO /ff- . SHUTDOWN PV SYSTEM EQUIPPED WITH RAPID AND REDUCE THE SHOCK HAZARD SHUTDOM IN ARRAY Z C0 0) T } C\I Z N C T— _o 0 In ZO v CIO O C 75; ' F- CU .-- a3 Q70 C>s U LIJ 0 OLL -0 cis Z 0 0O LU co 0 c � C O co � 0 0 CO T E2= 1 PV LABELS ce) 0746 \J SUNATION _ \ SJUNation Solar Systems ' 171 Remington Blvd. Ronkonkoma,New York 11779 ■. _ .may �. ---- -- -- — (631)-750-9454 �. NYSERDA 1 INSTALLER 43551 F p NUMBER JOB NUMBER _ 24146 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA DRONE rn co _) T } N Z N x O O O � a_ ZO U z O C 2 ' e F a) .-- cz U)cz U o cl OWNN, _ _ Z O O N t� c_ Af- *�fie; j. + '' -F x� �f • i _ �. - � � � • _ � Q SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP PV PHOTOS Fisher Engineering Services, P.C. 509 Sayville Blvd;- Sayville •New York 11782 Phone: (631) 786-4419 May 1, 2024 Attention: Town of Southold Building Department Subject: Engineer Statement for Solar,Roof Installation Donson Residence- 1687 RockylPoint Road, East Marion,NY 11939 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system(photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2020-Residential Code of New j York State (2020 RCNYS), Long Island;Unified Solar Permit Initiative (LIUSPI), 2017 I National Electric Code,NFPA 70/2014, Weathering Severe, Wind Exposure Category B, Climate Zone 4A. I have reviewed an'd certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence,meet�the requirements for wind and snow load and that the roof structure is adequate t1 carry the new loads imposed by the System. For the installation of the solar mounting, the rails shall be securely anchored to the roof utilizing lag screws that have been designed jfor wind speed criteria of 140 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable!to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 2"x8"& 2"x4" on 16" c.c., with an actual span of 14'-2.5", 14'-3.5", 8'-9", 18'-2", with plywood roof decking and one roof shingle layer on the house as shown ion the drawings. J hope that this letter serves and meets with the approval of the Building Department. Sincerely, NFw r� t William G. Fisher, P.E. Licensed Professional Engineer I I� �i ,I Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Expediting•Inspections Construction Estimates/Oversight Vic. o ` SOLAR'S MOST TRUSTED ® REC X --� / n AU R I iE 5 PRODUCT 5PEF FlEATIONS tis COMPACT PANEL SIZE p EXPERIENCE 430 WP REC 25 YEAR 20.6 PRoTRUSTT FT2 WARRANTY �O 22.2%'EFFIaENCY LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE 1 1 \�� %C-C 73.4±0.1 GENERAL DATA _ 36.4±0,1 ,es±o., , Cell type: 132half-cut REC heterojunction cells with lead-f ree, ❑ 6.os gapless technology,6 strings of22cells in series �� + Glass: 0.12 in solar glass with anti-reflective surface treatment 49.2 in accordance with EN 12150 ff Backsheet: Highly resistant polymer(black) 0.24±0.01 Frame: Anodized aluminum(black) s Junction box: 3-part,3 bypass diodes,lead free a IP68 rated,inaccordancewithlEC62790 < Staubli MC4 PV-KBT4/KST4(12 AWG) 0.43±0.01 Connectors: in accordance with IEC 62852,IP68onlywhenconnected Cable: 12 AWG solar cable,49.2+49.2 in 0.8±0.02 in accordance with EN50618 0 49.2 6.05 Dimensions: 73.4 x 40.9 x 1.2 in(20.88 sq-ft) : ----- Weight: 47.6 Ibs(21.6 kg) -.�'_1.8 0.9 27.3±0.1 Origin: Made in Singapore 1.2 Measurements in inches[mm] ELECTRICAL DATA P_roduc't Co_de':'RECxxxAA PURE 2 CERTIFICATIONS Power Output-PMAx(Wp) 400 410 420 430 IEC 61215:2016,IEC 61730:2016,UL 61730 Watt Class Sorting-(W) 0/+10 0/+10 0/+10 0/+10 IEC62804 PID IEC61701 Salt Mist Nominal Power Voltage-Vh1PP(V) AM 41.6 42.2 42.8 IEC62716 Ammonia Resistance Nominal Power Current-IMpp(A) 9.74 9.86 9.96 10.05 UL61730 Fire Type 2 Open Circuit Voltage V0 IEC 62782 Dynamic Mechanical LoadC(V) 48.5 48.8 49.1 49.3 IEC61215-2:2016 Hailstone(35mm) Short Circuit Current Isc(A) 10.60 10.67 10.74 10.81 IEC 62321 Lead-freeacc.to RoHS EU 863/2015 Power Density(W/ftz) 19.2 19.6 20.1 20.6 15014001,ISO 9001,IEC 45001,IEC 6294♦1 Panel Efficiency(%) 20.6 21.1 21.7 22.2 oVE .0- C F � g� Power output-PMAx(WP) 304 312 320 327 i°�k ` rep&FJree Nominal Power Voltage-VMPP(V) 38.7 39.2 39.6 40.3 TEMPERATURE RATINGS' Nominal Power Current-IMPP(A) 7.86 7.96 8.05 8.12 Nominal Module Operating Temperature: 44°C(±2°C) Z Open Circuit Voltage Voc(V) 45.7 45.8 46.0 46.2 Temperature coefficient of PMAx: -0.24%/°C s Short Circuit Current-Isc(A) 8.50 8.62 8.68 8.73 Temperature coefficient ofVoc: -0.24%/°C m Values atstandardtestc°nditions(STC:airmassAM1.5.irradiance10.75W/sgft(1000W/m2),temperature 77°F(25°C),based ona production spread Temperaturecoefflcientofl 0.04%/°C withatoleranceofP.,V«&ISc±3%withinonewattclass.Nominalmoduleoperatingtemperature(NMOT:airmassAM1.5.irradianceB00W/m2, sc' temperature 68'F(20'Qwindspeed3.3ft/s(I m/s).*Where xxx indicatesthe nominal power class(P.)atSTC above. 'The temperature coefficients stated are linearvalues 8 MAXIMUM RATINGS _ WARRANTY DELIVERY INFORMATION Operational temperature: -40...+85°C Standard REC ProTrust Panels per pallet: 33 System voltage: 1000V Installed byan REC No Yes Yes Panelsper40ftGP/high cube container: 792(24pallets) Certified Solar Professional Test load(front): +7000 Pa(1461bs/ft2)' System Size All s25 kW 25-500 kW Panels per 53 ft truck: 858(26 pallets) rn Test load(rear): -4000 Pa(83.5lbs/ft2)' Product Warranty(yrs) • 20 25 25 Series fuse rating: 25A Power Warranty(yrs) 25 25 25 LOWLIGHTBEHAVIOUR m Reverse current: 25A Labor Warranty(yrs) 0 25 10 Typical low irradiance performance of module atSTC: 'See installation manual for mounting instructions. Power in Year 1 98% 98% 98% o m ___________ ___ CL Design load=Test load/1.5(safety factor) Annual Degradation 0.25% 0.25% 0.25% a a Power in Year 25 92% 92% 92% w • i--------- '--------- 1---------- `--- __-' o See warranty documents for details.Conditions apply a """d"""''---------"""""""-----0 0 o _ a Availablefrom: W wlrradiance(W/m2) m m of Founded in 1996,REC Group is an international pioneering solar energy com pany dedicated to empowering consumers REC Solar PTE.LTD. with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low 20Tuas South Ave.14 R C C carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational Singapore 637312 headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. post@recgroup.com www.recgroup.com i ENPHASE. T! FE IQBM and IQBA Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,Software defined Easy to install microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary • Lightweight and compact with plug-n- I play connectors application specific integrated circuit(ASIC)which enables the microinverter+to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with highspeed Power Line Communication(PLC) digital logic and has superfast response times to changing loads and grid events,alleviating between components constraints on battery sizing for home energy systems. • Faster installation with simple two-wire cabling High productivity and reliability • •Y Produce power even when the grid is 25 . down* P 9 More than one million cumulative hours of testing Part of the Enphase Energy System,IQ8 IQ8 Series Microinverters redefine Series Microinverters integrate with the reliability standards with more than one Class II double-insulated enclosure IQ Battery,IQ Gateway,and the Enphase million cumulative hours of power-on Optimized for the latest high-powered App monitoring and analysis software. testing,enabling an industry-leading PV modules limited warranty of up to 25 years. Microgrid-forming • Complies with the latest advanced grid support— ; Remote automatic updates for the SAFETY latest grid requirements Connect PV modules quickly and easily IQ8 Series Microinverters are UL listed Configurable to support a wide range to IQ8 Series Microinverters using the as PV Rapid Shutdown Equipment and of grid profiles included Q-DCC-2 adapter cable with conform with various regulations,when Meets CA Rule 21(UL 1741-SA)and IEEE plug-n-play MC4 connectors. installed according to manufacturer's 1547:2018(UL 1741-SB 31'Ed.) instructions. I Note: +� I IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters(I07 Series,IQ6 Series,etc)in the same system. *Only when installed with IQ System Controller 2,meets UL 1741. i ••IQBM and IQBA support split-phase,240V installations only. ©2022'Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters, and other names are trademarks of Enphase Energy,Inc.Data subject to change. IQ8MA-I2A-DS-0069-03-EN-US-2022-12-27 IQBM and IQBA Microinverters Commonly used module pairings' IN 260-460 295-500 Module compatibility 54-cell/108 half-cell,60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 30-45 ( 32-45 Operating range V 16-58 Min./Max.start voltage V I'i 22/58 i Max.input DC voltage V 60 Max.continuous input DC current A 12 Max.input DC short-circuit current A 25 Max.module I A 20 Overvoltage class DC port II I DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA Q: r: Peak output power VA 330 366 Max.continuous output power VA 325 1 349 Nominal(L-L)voltage/rangez V 240/211-264 I Max.continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 47-68 AC short circuit fault current over 2 3 cycles Arms Max.units per 20 A(L-L)branch circuit' 11 I Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.8 97.7 i CEC weighted efficiency % 97.5 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -401Cto+60°C(-40°Fto+140•F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(H x W x D) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.21 Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 i Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor ' I CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB 3'"Ed.),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1- 2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)Pairing PV modules with wattage above the limit may result In additional clipping losses.See the compatibility calculator at https://Iink.enphase.com/module-compatibility.(2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQBMA-I2A-DS-0069-03-EN-US-2022-12-27 ` I e� SERIEq 100 FLASHED L FOOT Snap;Wack Residential PV Mounting Systems The SnapNrack line of solar mounting _." ' .° _ �=�--- - - #. s -'•'"<>x'1z �-�- at:a.acs.�„ „ ��;,ram.%•. t�:}. systems is designed to reduce total installation costs. The system features technical innovations proven on more than 20OMW of solar projects to simplify r, installation and reduce costs. Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an innovative b r solution to provide a long lasting watertight seal over r 1_ the life of the system.The Flashed L Foot provides a i single fastener flashed to an attachment composition Flashed 1_ Foot in 3 Simple Steps: shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a cleari level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at � No Cutting of shingles www.snapnrack.com/contact �I SnapNrack- Patent Pending PV Mounting Systems 1 s (T' I , M I i I Flashed L Foot Kit Assembled(1°spacer sold separately) Flashed L Foot Kit Parts(1°spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions SNAPNRACK CHANNEL NUT SNAPNRACK 92 DEGREE L-FCQf;CLEAR I 5/16-18 FLANGE NUT ``5JI618 X 3IN BOLT W[TH �s—LOCK WASHER SNAPMtAIX COM SMON FLASHING l 3.43 `%.RACK L-FOOT BASE hs SnapNrack Flashed Foot TechnicalData Patent Pending Materials 1 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapNrack, PV Mounting Systems (877) 732-2860 www.SnapNrack.com ej Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. I ER., I E 100 ROOF SnapNrack • • u ' n • Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical ; innovations have been proven to drive down costs and improve installation - - quality on more than 350 MW of solar = - ----- .' ` ' -- installations. _ Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) �< i= v3w' " `4f " module installation system. Series 100 UL is Listed ' to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for ! Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration i grounding hardware.The System's components provide; Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety,and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk i • No grounding lugs required for modules for additional savings Rail splices bond rails together, no rail jumpers required i • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools 1 required'(One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules p` LISTED PV Mounting System Patent Pending 2703 4 ,1 Stainless Bolt with Stainless Steel SnapNrack Standard Rail SnapNrack Bonding Bait with Split- Splice Insert Split-Lock Washer Lock Washer SnapNrack Banding SnapNrack SnapNrack _ Adjustable End Splice Clamp Top Banding Base +► Mid Clamp _ SnapNrack SnapNrack Banding Bonding SnapNrack Stainless `. Adjustable End Channel Nut Bonding Bolt with Clamp Bottom Channel Nut Stainless Hardware with �� Split-Lock Washers Split Lock SnapNrack Bonding Washer Adjustable End Clamp SnapNrack Bonding SnapNrack Bonding Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave L - UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer F IF IF IF SnapNrack Bonding Universal End Clamp SnapNrack Banding Standoff Clamp Assembly i SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut • Flange Nut Steel Flange Bolt - SnapNrack Stainless SnapNrack 92 Degree Flange Mill Finish Bolt Standoff L Foot SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(I-Hole _ SnapNrack Base Shown) � SnapNrack L Foot Metal Roof / Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Standoff Assembly L Foot Base with Flashing Roof Base with Bonding L Foot SnapNrack • • UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs. &Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules \ • Stamped Structural Engineering Reports for all 50 States \.Inding • SnapNrack Grounding Lug (One Lug per individual row of modules) \nty • 10 Year material and worksmanship (download full details at snapnrack.com) SnapNrack- Solar Mounting Solutions (877) 732-2860 www.SnapNrack.com rj Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved.