HomeMy WebLinkAbout50882-Z TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 50882 Date: 6/27/2024
Permission is hereby granted to:
Andersen, Eric & Pera alto Kell
745 Harbor View Ave
Mattituck, NY 11952
To: Replace and repair windows in-kind to an existing single-family dwelling as applied for
per Historic Preservation Commission approval.
At premises located at:
16766 Lower Rd, Southold
SCTM # 473889
Sec/Block/Lot# 69.-5-13.2
Pursuant to application dated 5/7/2024 and approved by the Building Inspector.
To expire on 12/27/2025.
Fees:
SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $250.00
CO-ALTERATION TO DWELLING $100.00
Total: $350.00
Building Inspector
�a TOWN OF SOUTHOLD —BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
� Telephone (631) 765-1802 Fax (631) 765-9502 htt s://www,sotitholdtownnv.,,,,ov
Date Received
APPLICATION FOR BUILDING PERMIT . .
For Office Use Only
m
PERMIT N0. Building Inspector'r "" '"""'
AY 7 202 .
Applications and forms must be filled;out in their entirety Into lete
applications will not,be accepted. Where the Apph¢ant is riot��i owner,an
Owner's Authorization form(Page,2)shall be corifPt�ete,
Date: cS 0 b /2-07J4
OWNER(S)OF PROPERTY:
Name: y-eljl (:r� ragcl_110 �`Cr�L P o-!;,.en TSCTM # 1000-
Project Address: i615 wiff 04
Phone#: b•31
. q Iq • L4 ZS Email: mil(. ,t�/bc401to fV10- f co1W
Mailing Address: (615 (der- 01 NL4
CONTACT PERSON: ,
°i i
Name: Cow, ;L
Mailing Address:
Phone#: (IO-3I •C 1L4 , J"TZ5 Email:
DESIGN PROFESSIONAL INFORMATION,:'
Name:
Mailing Address„
Phone#: Email:
CONTRACTOR INFORMATION: %,,,,.
Name:
Mailing Address:
Phone#: Email:
DESCRIPTION OF'PROPOSED"CONSTRUCTION %,
❑New Structure ❑Addition ❑Alteration Repair ❑Demolition Estimated Cost of Project:
❑Other $
Will the lot be re-graded? ❑Yes 1�No Will excess fill be removed from premises? ❑YeslKNo
1
PROP ERTY?kNFORMATI OfV
Existing use of property: C`� S"��en, �� Intended use of property:
t
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
S141161d- RVYS JI 064- this property? ❑Yes XNo IF YES, PROVIDE A COPY.
KJ Check BOX After Reading: The owner/contractor/ esignprofessional-is responsible for all drainage and storm water issues as-provided by.
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE,to the Buildi6g/4epartment forthe'issuance=of a Buildln&Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York,and other applicable Laws,Ord mahces,or Regulations;-for the construction of buildings,
additions,alterations or for removal or demolition as herein described The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors,on premises antl;in;building(s��fo�necessary inspections:False statements made herein are
,. .
punishable as a Class A misdemeanor pursuant to Section 210.45'of the New Ygrk Stat6,Penal Law,
Application Submitted By(print name , fx L 2vAuthorized Agent M/Owner
Signature of Applicant: rc -- Date: � /Z0�
I
k BUNCH
STATE OF NEW YORK Notary Public,State of New York
No.01 BU6185050
SS: Qualified in Suffolk County
COUNTY OF Sid V- ) Commission Expires April 14, 2
Yeam[;(k) being duly sworn, deposes and says that (s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the _e_ r
(Contractor, Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
Oc*-) day of M2 207Q
Notary Public
PROPERTY OWNER AUTHORIZATION
(Where the applicant is not the owner)
I residing at
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
our Unig4
Anne Surchin,Vice Chair ` �'y' 54375 Main Road,NYS Route 25
Allan Wexler ; PO Box 1179
Marina de Conciliis ° Southold,NY 11971
Jeri Woodhouse ° L�ru Telephone: (6)1)765-1809
a kimf@southoldtownny.gov
David Mammina �, � , �, � y•gov
Daryl Ketcham `
Kim E. Fuentes, Coordinator E C E OWE
Town of Southold Historic Preservation Commissi Rn III Ay 3 1 202
Certificate of Appropriateness Building Department
May 23, 2024 Town of Southold
RESOLUTION #05.23.2024.1
RE: 1675 Lower Road, Southold, NY. SCTM# 1000-69-5-13.2
Owner: Eric Anderson
RESOLUTION:
WHEREAS, 1675 Lower Road, Southold,NY, is on the Town of Southold Registry of Historic
Landmarks; and
WHEREAS, as set forth in Section 170-6 of the Town Law(Landmarks Preservation Code) of the
Town of Southold, all proposals for material change/alteration must be reviewed and
granted a Certificate of Appropriateness by the Southold Town Historic Preservation
Commission prior to the issuance of a Building Permit; and
WHEREAS, the applicant submitted a proposal on May 8, 2024,to replace all existing windows of
an existing single-family dwelling; and
WHEREAS, the applicant appeared before the Commission on May 23, 2024 to describe the
proposed improvements; and
WHEREAS, the proposal is described as Anderson A Series Windows (6 over) to replace 12 each
existing windows on the front fagade of the dwelling facing Lower Road, and the
remaining windows on the rear and sides of the dwelling to be replaced with Anderson
400 Series Windows; and
WHEREAS, the Commission has determined that pursuant to Chapter 170-4(E)(2) of the Southold
Town Code, the Commission has the authority to determine that some proposals do
not rise to the level of requiring a public hearing, as the proposal is de minimis in
nature; and
WHEREAS, the Commission has determined that the subject application is de minimis in nature and
therefore does not require a Public Hearing; and
Certificate of Appropriateness #05.23.2024.1
HPC,Anderson—Windows- SCTM No. 1000-69-5-13.2
Page 2
WHEREAS, the applicant shall submit to the Commissioners photographs of the finished
improvements upon completion; and
WHEREAS, the Commissioners may conduct a site inspection of subject premises once
improvements are completed; and
NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation
Commission determines that the replacement of the front fagade windows with
Anderson A Series Windows (6 over), and the remaining windows on the rear and
sides of the dwelling to be replaced with Anderson 400 Series Windows; meets the
criteria for approval under Section 170-8 (A) of the Southold Town Code; and
BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of
Appropriateness, subject to approvals by all involved agencies; and
BE IT FURTHER RESOLVED,that any deviation from the approved plans referenced above may
require further review from the Commission.
Motion made by: Commissioner de Conciliis
Motion seconded by: Commissioner Surchin
VOTES: AYES: Commissioners Surchin, Woodhouse, de Conciliis, Mammino and Ketchum. (5-0)
RESULT: Passed
Please note that any deviation from the approved plans as referenced may require further
review from the commission.
Signed: .m... Dated: May 29, 2024
Kim E. Fuentes
Coordinator for the Historic Preservation Commission
PP4 S 0 8 8 - ssesso�s
ANDERSENTM
WINDOWS & DOORS
CREATED DATE
SOLD BY: SOLD TO: 5/3/2024
Riverhead Building Supply Co Calverton
250 David Ct LATEST UPDATE
Calverton, NY 11933-3052 5/3/2024
Fax: 631-996-5109
OWNER
Thomas Buckley
Abbreviated Quote Report - Customer Pricing
QUOTE NAME PROJECT NAME_ QUOTE NUMBER CUSTOMER PO# TRADE ID
Eric Andersen DH's Unassigned Project . 5729379
ORDER NOTES: DELIVERY NOTES:
Item (sty Operation Location Unit Price Ext. Price___
None Assigned $771.40 $7,714.00
`--� RO Size: 321/8"x 56 7/8" - --Unit Size: 31 5/8"x 56 7/8"
TW2646, Unit, 400 Series Double-Hung, Equal Sash, Installation Flange, White Exterior Frame, White Exterior Sash/Panel, Pine
w/White- Painted Interior Frame, Pine w/White- Painted Interior Sash/Panel,AA, Dual Pane Low-E4 Standard Argon Fill
Simulated Divided Light(SDL) Division, 3 Wide, 2 High, Specified Equal Light Pattern, White, Pine w/White, 3/4"Grille Bar,
RO-32.125'—, Stainless Glass/Grille Spacer, Traditional, 1 Sash Locks White (Factory Applied),WhiteJamb Liner, White, Full Screen,
Aluminum
Insect Screen 1: 400 Series Double-Hung, TW2646 Full Screen Aluminum White PN:1610174
Unit# U-Factor SHGC ENERGY STAR Clear Opening/Unit# Width Height Area (Sq. Ft)
---------------------------------------- ------------------- -----------------------------------------------------------------------------------
A1 0.29 0.28 NO Al 27.8750 24.2500 4.71000
Quote#: 5729379 Print Date: 5/3/2024 1:29:08 PM UTC All Images Viewed from Exterior Page 1 of 4
�OANDERSEN-
WINDOWS & DOORS
CREATED DATE
SOLD BY: SOLD TO: 5/3/2024
Riverhead Building Supply Co Calverton
250 David Ct LATEST.UPDATE
Calverton, NY 11933-3052 5/3/2024
Fax: 631-996-5109
OWNER
Thomas Buckley
Abbreviated Quote Report - Customer Pricing
QUOTE NAME ' PROJECT NAME 'QUOTE NUMBER CUSTOMER PO# TRADE ID
Eric Andersen DH's Unassigned Project 5729379
ORDER NOTES: DELIVERY NOTES:
Item (3ty Operation Location Unit Price Ext. Price
100 10_— AA None Assigned $771.40 $7,714.00
— RO Size: 321/8"x 56 7/8" ____ _________- _-- —--Unit-Size:-31 5/8"x 56 7/8"
-- - TW2646, Unit, 400 Series Double-Hung, Equal Sash, Installation Flange, White Exterior Frame, White Exterior Sash/Panel, Pine
w/White- Painted Interior Frame, Pine w/White- Painted Interior Sash/Panel,AA, Dual Pane Low-E4 Standard Argon Fill
-31.625•---, Simulated Divided Light(SDL) Division, 3 Wide, 2 High, Specified Equal Light Pattern, White, Pine w/White, 3/4"Grille Bar,
-RO-32.12V Stainless Glass/Grille Spacer, Traditional, 1 Sash Locks White (Factory Applied), WhiteJamb Liner, White, Full Screen,
Aluminum
Insect Screen 1: 400 Series Double-Hung, TW2646 Full Screen Aluminum White PN:1610174
Unit# U-Factor SHGC ENERGY STAR Clear Opening/Unit# Width Height Area (Sq. Ft)
---------------------------------------- ------------------- -----------------------------------------------------------------------------------
A1 0.29 0.28 NO Al 27.8750 24.2500 4.71000
Quote#: 5729379 Print Date: 5/3/2024 1:29:08 PM UTC All Images Viewed from Exterior Page 1 of 4
II Item Qtv Operation Location Unit Price Ext. Price
l - .a ij-
1'711200 3 AA-AA None Assigned $1,628.45 $4,885.35
— - RO Size: 63 7/8"x 56 7/8" Unit Size: 63 3/8"x 56 7/8"
Mull: Factory Mulled,Andersen Ribbon Mull, 1/8 Non Reinforced Material
TW2646-2, Unit, 400 Series Double-Hung, Equal Sash, White Exterior Frame, White Exterior Sash/Panel, Pine w/White-
Painted Interior Frame, Pine w/White- Painted Interior Sash/Panel,AA, Dual Pane Low-E4 Standard Argon Fill Simulated
�31.62V 31.625- Divided Light(SDL) Division, 3 Wide, 2 High, Specified Equal Light Pattern, White, Pine w/White, 3/4" Grille Bar, Stainless
63 375"
R.-.215• Glass/Grille Spacer, Traditional, 1 Sash Locks White (Factory Applied), WhiteJamb Liner, White, Full Screen,Aluminum ,
Insect Screen 1: 400 Series Double-Hung, TW2646 Full Screen Aluminum White PN:1610174
Insect Screen 1: 400 Series Double-Hung, TW2646 Full Screen Aluminum White PN:1610174
Unit# U-Factor SHGC ENERGY STAR Clear Opening/Unit# Width Height Area (Sq. Ft)
---------------------------------------- ------------------- ----------------------------------------------------------------------------------
A1 0.29 0.28 NO Al 27.8750 24.2500 4.71000
B1 0.29 0.28 131 27.8750 24.2500 4.71000
Item Qtv Operation Location Unit Price Ext. Price
11 _njL 300 1 AA-AA-AA None Assigned $2,481.28_ $2,481.28
- -- - RO-Size:95-5/8"z 56 7/8" Unit Size: 95 1/8"x 56 7/8"
l 4 4 Mull: Factory Mulled, Andersen Ribbon Mull,-1/8 Non Reinforced.Material -- --
-- l TW2646-TW2646-TW2646, Unit, 400 Series Double-Hung, Equal Sash, White Exterior Frame, White Exterior Sash/Panel,
Pine w/White - Painted Interior Frame, Pine w/White- Painted Interior Sash/Panel,AA, Dual Pane Low-E4 Standard Argon Fill
BS I7S
Simulated Divided Light(SDL) Division, 3 Wide, 2 High, Specified Equal Light Pattern, White, Pine w/White, 3/4" Grille Bar,
Stainless Glass/Grille Spacer, Traditional, 1 Sash Locks White (Factory Applied), WhiteJamb Liner, White, Full Screen,
Aluminum
Insect Screen 1: 400 Series Double-Hung, TW2646 Full Screen Aluminum White PN:1610174
Insect Screen 1: 400 Series Double-Hung, TW2646 Full Screen Aluminum White PN:1610174
Insect Screen 1: 400 Series Double-Hung, TW2646 Full Screen Aluminum White PN:1610174
Unit# U-Factor SHGC ENERGY STAR Clear Opening/Unit# Width Height Area (Sq. Ft)
---------------------------------------- ------------------- ---------------------------------------------------------------------------------
Al 0.29 0.28 NO Al 27.8750 24.2500 4.71000
B1 0.29 0.28 B1 27.8750 24.2500 4.71000
C1 0.29 0.28 C1 27.8750 24.2500 4.71000
Quote#: 5729379 Print Date: 5/3/2024 1:29:08 PM UTC All Images Viewed from Exterior Page 2 of 4
• -1
Item Qtv Operation Location Unit Price Ext. Price
400 6 AA None Assigned $745.48 $4,472.88
RO Size: 321/8"x 52 7/8" Unit Size: 31 5/8"x 52 7/8"
S
J TVV2642, Unit, 400 Series Double-Hung, Equal Sash, Installation Flange, White Exterior Frame, White Exterior Sash/Panel, Pine
w/White- Painted Interior Frame, Pine w/White- Painted Interior Sash/Panel, AA, Dual Pane Low-E4 Standard Argon Fill
31.625 Simulated Divided Light (SDL) Division, 3 Wide, 2 High, Specified Equal Light Pattern, White, Pine w/White, 3/4"Grille Bar,
-RO-32.125" Stainless Glass/Grille Spacer, Traditional, 1 Sash Locks White (Factory Applied), WhiteJamb Liner, White, Full Screen,
Aluminum
Insect Screen 1: 400 Series Double-Hung, TW2642 Full Screen Aluminum White PN:1610173
Unit# U-Factor SHGC ENERGY STAR Clear Opening/Unit# Width Height Area (Sq. Ft)
---------------------------------------- ------------------- ----------------------------------------------------------------------------------
Al 0.29 0.28 NO Al 27.8750 21.7500 4.22000
Item Qtv Operation Location Unit Price Ext. Price
i 500 3 AA None Assigned $653.13 $1,959.39
RO Size: 301/8"x 40 7/8" Unit Size: 29 5/8"x 40 7/8"
TW2432, Unit, 400 Series Double-Hung, Equal Sash, Installation Flange,White-Exterior Frame,White Exterior Sash/Panel, Pine
w/White- Painted Interior Frame, Pine w/White--Painted-lnteriior Sash/Panel,AN Dual Pane Low-E4 Standard Argon Fill
29.825'- Simulated Divided Light(SDL) Division, 3 Wide, 2 High, Specified Equal Light Pattern,White, Pine w/White, 3/4"Grille Bar,
RO-30126' Stainless Glass/Grille Spacer, Traditional, 1 Sash Locks White (Factory Applied), WhiteJamb Liner, White, Full Screen,
Aluminum
Insect Screen 1: 400 Series Double-Hung, TVV2432 Full Screen Aluminum White PN:1610120
Unit# U-Factor SHGC ENERGY STAR Clear Opening/Unit# Width Height Area (Sq. Ft)
---------------------------------------- ------------------- -----------------------------------------------------------------------------------
A1 0.29 0.28 NO Al 25.8750 15.7500 2.84000
Quote#: 5729379 Print Date: 5/3/2024 1:29:08 PM UTC All Images Viewed from Exterior Page -3 of 4
SUB-TOTAL: $21,512.90
FREIGHT: $0.00
LABOR: $0.00
TAX: $1,855.49
TOTAL: $23,368.39
CUSTOMER SIGNATURE DATE
*All graphics as viewed from the exterior. ** Rough opening dimensions are minimums and may need to be increased to allow for use of building wraps
or flashings or sill panning or brackets or fasteners or other items.
Thank you for choosing Andersen Windows & Doors
Quote#: 5729379 Print Date: 5/3/2024 1:29:08 PM UTC All Images Viewed from Exterior Page 4 of 4