Loading...
HomeMy WebLinkAbout50206-Z S�FFOI�-c Town of Southold off. oG. 3/25/2024 a y� P.O.Box 1179 a 53095 Main Rd Southold;New York 11971 CERTIFICATE OF OCCUPANCY No: 45067 Date: 3/25/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1330 Sigsbee Rd, Laurel SCTM#: 473889 Sec/Block/Lot: 144.-1-5.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/11/2023 pursuant to which Building Permit No. 50206 dated 1/11/2024 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwellingas applied for. The certificate is issued to Joseph,Tracy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50206 3/8/2024 PLUMBERS CERTIFICATION DATED A hor' a Signature ��o�SUEFill/(y TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE , . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50206 Date: 1/11/2024 Permission is hereby granted to: Joseph, Tracy 26 Greenway Ter Forest Hills, NY 11375 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 1330 Sigsbee Rd, Laurel SCTM #473889 Sec/Block/Lot# 144.-1-5.2 Pursuant to application dated 12/11/2023 and approved by the Building Inspector. To expire on 7/12/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector O�'�'OF SOUj��l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 sean.devlintc�town.southold.ny.us QUNT`I, �l BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Tracy Joseph Address: 1330 Sigsbee Rd City,Laurel st: NY zip: 11948 Building Permit#: 50206 Section: 144 Block: 1 Lot: 5.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Hytech Solar License No: 54187ME SITE DETAILS Office Use Only Residential X Indoor Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1.ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel X A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 14.985kW Roof Mounted PV Solar Energy System w/ (37) SEG 405BMD HV Module: AC Combiner Panel, Line Side Tapped Notes: Solar Inspector Signature: ` Date: March 8, 2024 S.Devlin-Cert Electrical Compliance Form OF SOOTyo� # TOWN OF S UTHOLD BUILDING PT. o �Y� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: u av e *--X�; o� 4' Mee 1,4 dom1A Arl- A" ioeg eJ 14 04,tper o e C6, DATE INSPECTOR OF SOUTgOIo # # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [WFINAL C 04p-, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ' a 0. DATE INSPECTOR 124.15 Metropolitan Avenue Queens NY,11415 F E B 2 0 2P4 'n:646-626-6299 E):filing@srsolardesign.com Jan 24,2023 S&R Solar Design 124-15 Metropolitan Avenue Queens,NY 11415 ATTENTION: Town of Southold REFERENCE: Tracy Joseph- 1330 Sigsbee Rd,Mattituck,NY 11952 Solar Panel Installation To Whom It May Concern: Based upon our site visit conducted on Jan 24, 2023 , I,Naresh K. Mahangu,PE certify that the installation of solar panels on this existing roof were as per the Town of Southold approved plans, and in accordance with the following Codes: • 2017 NEC(NFPA 70) • 2020 NYS RESIDENTIAL CODE, IBC 2015. • ASCE 7-16 We hope this meets your needs. If you have any further questions regarding this matter,please call this office at your convenience. OF t1,i Very Truly yours, � 4�1{ A� � Naresh K.Mahangu New York State License No.089068 '~ ` rn ArQ �f� 6S Jan 24,2023 124-15 Metropolitan Avenue Queens NY, 11415 (T): 646-626-6299(E):filing@srsolardesign.com FIELD INSPECTION REPORT I DATE COMMENTS b FOUNDATION (1ST) ------------------------------------- FOUNDATION (2ND) z 0 w y ROUGH FRAMING& PLUMBING vi r INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS y sZ ro N O z x d b �5�FF0l��o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtomm.gLov f � Date Received APPLICATION FOR BUILDING PERMIT Q �, For Office Use Only PERMIT N0. �6 Building Inspector: • �eq�t Applications and forms must be filled out in their entirety.Incomplete �tE �CP nn�d applications will not be accepted. Where the Applicant is not the owner,ana „y�o�`"off Owner's Authorization form(Page 2)shall be'completed. Date: 18 1 a I3 OWNERS)OF PROPERTY: Name: I rG JUSe SCTM#l000- 1144.00- QI o® — 005- 0DZ Project Address: 1330 & /cif k9d M�—(TUC � ( � �5oA Phone#: q'„- C7. Is. 4LI S3 . Email: nut )' I r onOgmcid 'Corn Mailing Address: 1 J? 7J & sbc t '.15' CONTACT PERSONt ' Name: a Mailing Address: -A yC bC A� U l n c)ta Phone#: .U3 ' Sci5 ,5 11 Email:swX-Ir C a C DESIGN PROFESSIONAL INFORMATION: Name: Nfi Mailing Address: ey-iiq mtro o to-n C n Phone#: ( 4U (p Z(o • (Ozclq Email:f i l I nq @ Srsolard e S I n c om CONTRACTOR INFORMATION. Name: . Un C Mailing Address: %h jM tQnA VC Qv Lr _ Iv O� Phone#:�3 (� X Email:S) C U6411 L DESCRIPTION.OF PROPOSED CONSTRUCTION, 12 C),o f ew Structure ❑Addition ❑Alteration Repair ❑Demolition Estimated Cost of Project: Yo ❑ther ,Solar no I just liati on $ � Will the lot be re-graded? ❑Yes V4io Will excess fill be removed from premises? ❑Yes No 1 PROPERTY INFORMATION Existing use of property:51 n l.Q fC1 I Intended use of property: S I2L;c-m( 1 C Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes f(No IF YES, PROVIDE A COPY. El Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in,building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 220.45 of the New York State Penal Law. Application Submitted By(print name): 71m o fk y Hau iAuthorized Agent ❑Owner Signature of Applicant: -� Date: I L—L—z 3 STATE OF NEW YORK) S ; COUNTYOF5U1 bI ) -rng th,m being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the c( o rocur C-4\j,cc l . SU arInc) (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this �ay of ��YI�LJ , 20,J3Ila 11'•'•••n ST ••• :!�o ary P' ' 1V0 •O PUa�rsed RYP o:S 01D �s"/TOIk LIC; PROPERTY OWNER AUTHORIZATION s '; I639j20�0unty 9 • S (Where the applicant is not the owner) ��sJ,••.• ••.•',yo ar�EXPIRES�*1�a��`` I, -FrCni Sbsrpl'1 residing at 1330 SI QSre 2J MW1 I fU C L/ do hereby authorize J N.f CCh S O 10,r , I Yl C to apply on my b alf to the Town of Southold Building Department for approval as described herein. •wner's I n Date �i};I��Q ner's�Name, 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, �f nCV �VS�VY I residing at 133(� sIUJ � �d (Print property owner's na;ne) (Mailing Address) fC`Cf t Ij1 ACV A N y 053- do hereby authorize ttwtrchG -r I n( Agent) to apply on my behalf to the Southold Building Department. AJ,0-r-AA La,� 121�' 23 • one-I Z. a� r ' (Date) I'L- ®wn67r sWdi To guffOt'K. BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road - PO Box 1179 G, &F Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrOsoutholdtownny.dov- seand(a-southoldtownny. ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: C Name: License No.: ME-E41g email: 7@ d)hO" . CO Phone No:(,31-S95-SSOO 141 request an email copy of Certificate of Compliance Address.: WQSYI lrotW 4VCIOCjN Sho JOB SITE INFORMATION (All Information Required) Name: Tr Address: e Cross Street: - �wd Phone No.: 11 5 Bldg.Permit#: email: j i 011 (@ M0J - CO Tax Map District: 1000 Section: 1 y4. 00 Block: 0 I. 00 Lot:00c• C1p BRIEF DESCRIPTION OF WORK (Please Print Clearly) I nstail a1-i on t�-F 3-7 S of a Qo ni?I� i2-00 f hop Check All That Apply: Is job ready for inspection?: []YES [✓NO ❑Rough In ❑Final Do you need a Temp Certificate?: [2]YES [-]NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xrsx Suffolk County Dept.of Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE Name TI-MOTHY HOUSTON �..-. Business Name This certifies that the nearer is duly licensed HYTECH SOLAR INC 3y the County of suffolk License Number:ME-54187 Rosalie Drago Issued: 10/03/2014 Commissioner Expires: 10/01/2024 j i i i i i i Suffolk County Dept.of y Labor,Licensing&Consumer Affairs N' i TOME IMPROVEMENT LICENSE �. Name 1 TIMOTHY H HOUSTON Business Name 'his cerrfies:hat the 3earer is duly licensed hYTECH SOLAR INC :y the County of Suffolk License Number:H-58891 Rosalie Drago Issued: 03/12/2019 Comm�ssiorer Expires: 03/01/20225 A`�o® CERTIFICATE,�OF;LIABILITY INSURANCE DA tiDa,2o2 ' THIS CERTIFICATE'IS ISSUED ASA MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER NAME: Danielle Polonczyk Brown&Brown Metro,LLC PHONE (856)552-6330 856 840-8484 AIC No Ext:.. AIC No: ( ) 10 Lake Center Drive AODREss: •Danielle.Polonczyk@bbrown.com Suite 310 INSURER(S)AFFORDING COVERAGE NAIC# Marlton NJ 08053 INSURER A: Southwest Marine and General Insurance Company INSURED INSURER B: Merchants National Insurance Company Hytech Solar Inc INSURER C: New Jersey Manufacturers Insurance Company 12122 6 Washington Avenue ,< INSURER D INSURER E: Bayshore NY 11706 INSURER F COVERAGES. CERTIFICATE NUMBER: 23-24 MASTER REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD. INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPE OF INSURANCE I SD yyyD ' POLICY NUMBER MWDD EFF MMIDD kX—P LIMITS COMMERCIAL GENERAL LIABILITY 2,000,000 ' EACH OCCURRENCE $ CLAIMS-MADE FX OCCUR PREMISES Ea occunence' $ 100,000 MED EXP(Any one person) $ 5,000 A PK202300015171 12/11/2023 12/11/2024 PERSONAL&ADV INJURY $ 2.000,000 GEN'LAGGREGATE LIMIT APPLIES PER: GENERALAGGREGATE $ 4,000,000 POLICY ❑X JET LOC 'PRODUCTS-COMP/OPAGG $ 4,000,000 i OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANYAUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY - AUTOS ONLY Per accident X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 2,000,000 B EXCESS LIAB CLAIMS-MADE EXL0003762 12/11/2023 12/11/2024 AGGREGATE $ 2,000,000 DED RETENTION$ $ WORKERS COMPENSATION X STATUTE ERH AND EMPLOYERS'LIABILITY YIN 100,000 ANY PROPRIETOR/PARTNER/EXECUTIVE' E.L.EACH ACCIDENT $ C OFFICERIMEMBEREXCLUDED? NIA W42088-5-23 12/11/2023 12/11/2024 (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 100,000 If yes,describe under 500,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179- AUTHORIZED REPRESENTATIVE Southold NY 11971 _..• 01988-2015 ACORD CORPORATION. All rights reserved. ACORD 26(2016/03) ThWACORD name anti logo are registered marks o'f ACORD L.COVERAGESI- ADDITIONA Ref# Description` Cov®rage.Code.' F6irri No. Edition Date Designated Construction Proj Agg-Capped` , :,. Limit 1 Limit 2 Limit 3 Deductible Amount = °Deductl_ble_'Type Premium ' 5,000,000 . Ref# Description - - Coverage Code Form No. Edition Date Li mited.Fu ng!/Bacteria Limit 1 Limit 2 Limit 3 Deductible=Amount Deductible Type Premium 25,000 50,000 . Ref# Description Coverage Code Form No. Edli on Date. Cyber Suite Limit 1 Limit 2 Limit 3 Deductible Amount Deductible Type Premium 100,000 .1,000 Dollars Ref# Description _ Coverage•Code Form No. Edition Date Errors&Omissions ERROM Limit 1 Llm(t 2 Limit 3 Deductible Amount Deductible Type Premium' 1,000,000 7 Ref# Description Coverage Code Form'No. Elution Date. CONTRACTORS Pollution Limit 1 Limit'2 Limit 3 Deductible Amount Deductible Type Premium 1,000,000 25,000 Ref# Description Coverage Code Form No. Edition Date Experience Mod Factor 1 EXP01 Limit 1 Limit 2 Limit 3 Deductible Amount Deductible Type Premium Ref# Description Coverage Code Form No. Edition Date Limit 1 Limit 2 Limit 3 Deductible Amount Deductible Type' Premium Ref# Description Coverage Code .Form No. Edition Date Limit 1 Limit 2 7-7 Limit 3 Deductible Amount Deductible Type'. Premium Ref# Description Coverage Code Form No. Edition Date Limit 1 Limit 2 Limit 3 Deductible Amount Deductible Type Premium Ref# Description Coverage Code Form No. Edition Date Limit 1 'Limit 2 Limit 3 Deductible Amount Deductible Type Premium Ref# Description' Coverage Code Forth No. Edition Date Limit 1 Limit 2 Limit 3 Deduatlbfe Amount Deductible Type Premium tOFADTLCV "" Copyright 2001,AMS Services,Inc. DocuSign Envelope ID:45DC4140-1512-4865-A055-FAF17C798225 Workers' YO K CERTIFICATE OF STATE Compensation Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured - _ 631-595-5500 , Hytech Solar Inc. " 6 Washington Avenue71 Bayshore,NY 11706•, 1 c.NYS Unemployment Insurance Employer Registration Number of insured Work Location of Insured(Only required if,coverage,is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) , . Number , ' '" . . 81-2376682 21 Name and=Address'of Entity Requesting Proof of Coverage 3a.'Name of Insurance Camer• (Entity,Being Listed as the Certificate Holder) ;. New Jersey Manufacturers Insurance Company Town of Southold 3b;Policy Number of Entity..Listed in Box"la" PO Box 1179 W42088-5-23 Southold, NY 11971 3c.Policy effective period 12/11/2023 to 12/11/2024 3d.The Proprietor,Partners or Executive Officers are Q included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed In box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy Indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business Is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Danielle Polonczyk (Print name of authorized representative or licensed agent of insurance carrier) DocuSigned by: Approved by: 5p�,�t,((�, p(p (� 12/4/2023 18A6885D20(JBitlf6ature) (Date) Title: Broker Agent/Insurance Producer Telephone Number of authorized representative or licensed agent of insurance carrier: 856-552-3010 Please Note:Only insurance carriers and their licensed agents are authorized to Issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov DocuSign Envelope ID:45DC4140-1512-4865-A055-FAF17C798225 Workers' Compensation Law e Section 57. Restriction on issue.of permits and the entering into contracts unless compensation is secured. 1. The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the.employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general'or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. Nothing herein, however, shall be construed as creating any, liability on,the.,part of: such state or 'municipal department, board, commission or office to pay any compensation to,any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any,work involving the employment of employees in a hazardous employment defined by this chapter; notwithstanding anq'•general br special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that compensation for all employees,has been secured as provided by this chapter. C-105.2(9-17) REVERSE INE'WK Workers' CERTIFICATE OF INSURANCE COVERAGE ATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS-disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured' HYTECH SOLAR INC 631-595-5500 6 WASHINGTON AVENUE BAY SHORE, NY 11706 „ fc.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage.is specifically limited to , certain locations in New York State,i.e.,Wrap-Up Policy) 812376682 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier' (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company., , Town of Southold: 3b.Policy Number of Entity Listed in Box"l a" 53095 Route 25, PO Box 1179 DBL486077 ; Southold, NY 11971 3c.Policy effective period 05/06/2023., : , . to 05105/2024 4. Policy provides the following benefits: © A.Both'disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees,eligible under the NYS Disability.and,,Paid Family Leave Benefits Law., B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative'or licensed agent of the,insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. I Date Signed 5/9/2023 By C � Wi G7�i (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive,Officer -. IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent-of that carrier;this*certificate is COMPLETE. Mail it directly to the'certificate holder. If Box 4B,4C or 5B is checked,,this certificate is NOT COMPLETE forpurposes of Section,220;Subd.'8 of the NYS Disability.and Paid Family Leave Benefits-Law..It must be emailed to PAU@wcb.ny.gov or it can.be mailed for - completion to the Workers'Compensation Board, Plans Acceptance,Unit,PO Box 5200, Binghamton,NY-13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if sox 413,4C or 59 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form, DB-120.1 (12-21) 111 Jill DB-120.1 (12-21)°IIII�I Additional Instructions for Form DB-I-;Q.l By signing this form, the insurance 6arri4r-ident fied'in Box 3 on this'.f6rm is'ce'rtifying that it is insuring the business referenced in Box I a for disability-and/or Paid Family Leave benefits under the NYS Disability and Paid Family Leave Benefits Law. The insurance"carrieir or its licensedagentWillsend thii Certificate'of,Ins'dr-ance C6v&rag&(Certificate')'to' the entity listed as the certificate holder.in.Box2., The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within:30 days IF there are reasons other than nonpayment of premiums that cancel the policy or,eliminate the insured from coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise, this,6*6'r'tific"ate"is valid for one year after this form is approved by the insurance carrier ,or its licensed agent, or until the policy expiration date listed in Box 3c,whichever is earlier. This Certificate is issued as a matter of information.only and confers no rights upon the certificate holder. This Certificate does not amend, extend or alter the coverage afforded by the policy listed,-nor does i.t.confer.any rights.or"responsibiliti..es beyond those contained'in-'ihe rbf6rdn'ded policy. This Certificate may be used as e'vidience of a NYS disability and/or Paid Family Leave benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or Paid Family Leave benefits policy indicated on this form, if the business continues to-be named.on a permit,,license or contract issued by a certificate holder,the business must provide that certificate hold-or With a new'Cirtificiate of ihsura'n6e Coverage for NYS disability and/ or Paid Family Leave Benefits or other authorized proof that the business is complying.With the mandatory' coverage requirements of the NYS Disability and Paid Family Leave Benefits Law.' NYS DISABILITY AND PAID"FAMILY LEAVE BENEFITS LAW­ §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit-for or in connection with any wotk-involvihg the employmentof employees,inL employment as defined in this article, and not withstanding any general or special statuterequiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand and twenty-one, the payment of family leave benefits for all employees has been secured as provided by this article. Nothing-herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. Th' state h required by law to enter into (b)The teormunicip boa;@I department board, commission.or office aut.,oriz.ed or any contract for or in connection with any work involving the employment of employees in employment as defined in this article,and notwithstanding any general,or.special statuterequiring or authorizing any-such contract,'shall'hot enter into any such contract unless proof duly subscribed-by an.insurance carrier is�produced in,a form satisfactory-to the chair, that the Oayffient of disability,benefits and after January first,-two thousand eighteen, the payment of familywleaV6 benefits for all employees has.been secured as proyide'd by this article:-,, Db.,120.1(12-21)Ae49rse ELECTRICAL EIOIHJ-1, 1 SOLAR w EOLIDEovnTH RAPID sHuroowN 2 MIMMUN K-AC RATING OF ALL BREAKERS TO BE IM Enphase AC cable In Consumption CTs S VERIFY GROINUNG ELECTRODE IS IF NONE INSTALL NEW VERNON HISTORY free of under module 4 ALL CONDUCTORS ARE COPPER UNLESS NOTED OTHERWISE OB W DATE DESCRIPTION I I ACSDCGROUMINGCONDUCTORS PERNECARTICLE RE 1 Ivumxl O114n.1 I 6 8E0A3(A)T4RU(M CONNECTED AS PER BMAGW,OSCAR,S l SIZEDPER260.122 ALL EXTERIOR MOUNTED COMBINERS,JUNCTION O { BOXES,�OEUGH,DIBCON ECTS,ETD SHALL BE MR LATITUDE ...... I I I AND AN HOPING FALL 1 TO PROMO SAS PESION JOINTS u.B{gq � I I 7 AND F99AENTS OF ALL CONDUITRURSAS PER NEC NBGUREMEm LONGITUDE TOTAL RATING OF ALL OVEIC=Wff DENCB,ammo NG .72.63{020 8 MAW BURY OVERCWIENT DEVICE.SHLLL NOT EXCEED I T e l l N G I I AMPAC TY Of THE BUSBAI UnLIZE SOLAR MA\Ral,'1 i ( I 6 THE N BraTSA B MX.YCINVEtTERS.THBRE ARE NO UTILTY COMPANY: ...... ItJ )BREAKERU I I DC 4IRCIXff OUTSIDE OF THEARRAY PERIMETER. PSEO LI 1 BRANCH-I COMA NUB I I I 'PROVIDE RDAT Y ACCOUNT NUMBE R EN PHASE CONNECTION WTH"WAN -CUSTOMER OWN® ENVOY - INIMEAXER 16 ELECTRICAL OEMATION EQUMENT CONNECTED-WITH 6B611AOµ BR CH-2 APPROPRIATE HAZARD AND OL7IPUT RATINGS OF PV KI LOgTRaM ovERCUaREaT MOTFCIIPN Aa PER—AR-1.1 rMAt: f I I I CUSTOMERS MERNEI Q � I owrw�e PmrrR..hr MrMs r..mrineueM...urc.r„eua.m, � 11 e.n.rnr a...nn na.ra.,mr r,tl.Pmrmk III BRANCH-3 ~—I COr 110N Q I T /1 Z i ^err roe.Iww..n.......,r.e�3menoM.rro Im B HOMEOWNER- _#1-Solar Module 1 0 1 ��-G I rm.rer..r rhh m..r.. r h e�vk. L—__#2-Micro Inverter Z r MeG NOTES p I Tracy Joseph D I EXTANTROOFTOPCONDUITSANT,INCLUDING TRk ® I i—• I LU EXTENT F GA LBLEINS CONDUITS,AROOFTOP CABLE TRAYS, Household N WNIERE LNG SHONOT INSTRUCT OOF70PAC ACCESS LA IS WHERE TkE OFR REQUIRED RUCTR00FlDP ACCESS LANORJOS, ADDRESS: I (—+ I I CLEAR PATH L REOUR®CLEARANCES.C IT N ® I I I BIPRACnCABLETOAWIDT/BE AREAS,CONDUTSANDPIPING 1330 Sigfbfe Rd, SHALLBE DESIGNED ANT INSTALLED TO FACILITATE ACCESS I ANOMMM.TRIPPING HA7ARDS.STEPS OR RAMPS(OR Matthuck,NBwYork PLATFORMI WTH STEPS,RAMPS OR LADDERS SHALL BE 11952 PROVIDED THAT ARE CONSTRUCTED OF NONCOMBUSTIBLE GRWNONG ELECiROOE COLD EAiN fOSYK!(n MATERIAL,EOUIF4ED WIMiWUN(RS,AND DEBIGlE9 TO ALLOW G I I I ~I (1)µAWG__. GROUND ROD (1, AWG IA _ C066116RINmc I ANY CONDUIT OR PIPING INSTALLATIONSTLAT EXCEED IFOOT CONTRACTOR: I I { CU am U D a'LONG CU GEC — 218B7(A)1 I P05M6)IN HEIGHT ABOVE THE ROOF SURFACE,ORMORETHE2E 266µ IN COMPLIES W NEC 260M I NOTES NIOMMI N WIDTH,TO BE READILY TRAVERSED STEPS, Hytµh Sol.,-� 250.52(A)6(8) I MAWS,PLATFORMS AND LADDERS SWILL NOT BE RACED INT-------J ARMSORNAM RTATWOULDOBSTRUCTANYDDOROR ADDRESS: #4-Solar Load Center I MlAA OP EGRESS.ALL CONDUITS AND PIPING INSTALLATIONS 89L AC DISCONNECT I WALL BE COLORCODED WITH CONTINUOUS,DURABLE AND {Washington AYE,Bay hare. #3-Roof to GENERATION PANEL #5- Maim 06-E CIE Unity WEATRERPROOF REFLECTME OR LUMINESCENT MARKINGS AS NY 11708 P U^"'^'tl FOLLOWS,AND FOR TIE CONDUIT-0 PIPING INSTALLED,SHALL Junction Box Service Panel Meter OE CONTINUOUSLY LABELED IN AN APPROVED MANNER pNONE.. SEE SYSTEM OUTPUT RATINGS CHART BELOW PROPOSED EOURMBR LOCATION {3114E6•6640 FOR BREAKER SIZING UTILITY METEi EXTERIOR OF HOME EMAIL: MAN SERVICE PANEL BASEMENT ic onn ecWytoe hsolar.com SOLAR MODIA-8514 ROOFTOP MASTER SOLARLOAOCErTERN) EXTERIOR OF HOME ELECTRICIAN: SOLAR SYSTEM OUTPUT RATINGS HOUSE MSP Timothy Houston EGUNPMENT TOTAL BRINED MODEL NOMINAL OUTPUT CURRENT 240V V... 128MO ME LICENSE# NOMINAL OPERATING VOLTAGE 1." PhM NnBN ME44107 SOLAR MODULES 37 BEG BEG-40643MD�V Phase PV MAX DC OUTPUT 14.gi kWME PUTOUTS# MICRO INVERTERS 37 Enph.. IOOPLUS-72.248 PV MAX AC OUTPUT 11.1 kW MA. 6i/4q-fN6 INTERNET MAX AC OPERATING CURRENT q A Rods 160 COMMUATIONS 1 Enphsa Envoy-2P,16AOCP LEGEND WIR SC HEDULE '�p�j7 FNP NIC SOLAR 08L AC TOTAL POWER OIRPUT•PTC RATING X# ER F EOUIPII 1 CONDUCTOR COLOR SUDS CONDUIT O DISCONNECT 126A BUS SERVICE RATED MODULES X M.INV EFf `A 9 GENERATION 1 SQUARED LOADCENfERV 1 SOLAR MOWLE A TMTL2 BR #12 2 INH"Seh.oul.WPJC a PANEL PTC RATING OC 376.E W ? ?{TY E'+ t; 2 MICRO INVERTER ECO TI#IN-2 G ANO 1 2 ¢ LOAD CENTER MAIN BREAKERW/TIE DOWN OCP{8A MAX INVERTER EFFICIENCY q% I ,.,� •' 3 JUNCTION SDz� 1 OR #10 2 rJ hi CIA-. _ B 1GVN2 Nt^San.anc Bo we a 08 BS TOTAL POWER OUTPUT DC(Y01 13,g8.1f fr" " � ')a3Li�,-i�ZA� l SOLAR LOADCErTEt ECO TiNN,2 O #6 1 '9p� 6 WIN SERVICE PANEL TAVNB OR Oil 2 F331014 Branch Inlormatlon Bmeh•/ Bmmh•2 9nnah-7 6 UMMY METER C ECG THWNB O #12 1 Nt^7dreWl.80 we SCALE PROJECT TOTAL MODULES 13 12 12 }.,�0-r ^{ O N 1"SaMbd.eo wC T WN-2 B R W to 3 HITS 20274fT81B267ge6 BRANCH VOLTAGE 246V 24M/ layECO T#YK2 O SO �./w f� 1 PHOTO-VOLTAIC INVERTER AMPERAGE 1.21 A 1.21 A 1.21 A E BIDS O i6 2 s iw ar. ELECTRICAL 34 NE DIAOMM BRANCH AMPS X 1.26 11.9126 A 18.16A 18.16 A GOP 62I7,2P,20 A 621T,2P,20 A 62n,2P,28 A I r.- E-100.08 1 PACE 1 OF 1 SOLAR INDIVIDUAL PERMIT PACKAGE SATELITE IMAGE CODE INFORMATION o a r ♦ f". APPLICABLE CODES,LAWS AND REGULATIONS —j o p 0 m . s 14.99KWGRID-TIED PHOTOVOLTAIC SYSTEM 0 D D oe = 000 �+ 2016 Intemational Building Code(IBC)/2020 BCNYS Q r 0 M A 2018 International Residential Code(IRC)/2020 RCNYS � J Q• 0 N � a n HOMEOWNERS NAME: - 20181ntemational Fire Code(IFC)/2020 FCNYS w p N A ` i a T R AC Y J O S E P H 2018 National Electric Code(NEC) t h1 o n a �� 2018 International Energy Conservation Code(IECC) 12020 m ECCCNYS GENERAL NOTES e s ///rr9 PROJECT LOCATION: 1. SOUS PANELS MU BE(13)SIG AO!-WD-HV—FV NODULES,AND (33) Ln •Z IQBPws-ll-3-US NICND IRVENTEAS m i (917)975-4453 2. MVmE A.C.DISCONNECT:EEOVAC,PIERIA IN. 0 ; 3. THE AC DISCOXNECI WILL BE LABELED AS'UTILITY DISCONNECT AND PHOTOVOLTAIC SYSTEM LOON-OUT'LOCATED WITHIN VIEW OF THE ELECTRIC UTILITY w ""EIR j W 1330 SIGSBEE RD ` Z s I,2 1'N If IT IS NOT PRACRCAE TO LOCATE THE AC DISCONNECT WITHIN VIEW OF THE W i m Y UT[L1TI NETEA,TNEN A WCATHERFROOF PLAQUE SHOWING THE LOCATION OF THE MATTITUCK,NY, 11952 I SWITCN NUST BE INSTAMDWMI.VHFB OF TIE WMIC LmLITY NETEA. o 4, ALL W NG TO NEST THE NATIONAL ELECTRICAL CODE. ^•' 7 m F 6, THE RAFTERS AS INDICATED NAVE BEEN ANALYZED AND DEEMED SUFFICIENT TO li m F e SUPPORT TILE ADDED LOAD OF THE SOIAII PANELS AND CORRECTORS. Q U Q W TOWN OF SOUTHOL D THE SOLAR FAN—.1 NOT BE INSTALLED ON AN ER 5 NG ROOF—I NAS � � � J NONE THAN 1 LAYERS OF ASPHALT ROOF SHINGLES,UNLESS ADEQUATE MEANS OF F N Q UTILITY:PSEG LONG ISLAND 9UPg0.T ARE PROV DED AS PER TNFSE DRAWINGS. w N ❑ B. TILE Nut""sPADNG BETWEEN THE STANDOFFS SHALL BE EA'O.C. L F W W N f Z 9. THE SOLAR PANEL MOUNTING SISTER WILL BE BY UNIRAC NNT SYSTEM. — W � JQ Q ATTACHMENT DETAIL LINE DIAGRAM SHEET INDEX w D J Z PAGE 1 F SITE MAP-LINE DIAGRAM-DETAIL J PAGE2 Q ROOF PLAN&CROSS SECTION Z STRING 1(CONNECTED TO PV MODULES) m a ❑ PAGE 3 It N F ARRAY INFORMATION AND MOUNTING DETAIL O W M - F7 STRING 2(CONNECTED TO PV MODULES) OO 0 UI (Bj sns ae E z• PAGE 4 1.- 0 Z w SERRA7®IisNGE HEx SCREW STRING 3(CONNECTED TO PV MODULES) ROOF PLAN LAYOUT N m -1Q 0 Eq Z _ %B PAGE 5 N p 0 SOLAR PANEL LAYOUT •TA6m 36 . �6 N r > Q (EIGHT ADxrrrvs4T I NEW SOLAR AC 125A PAGE B m 0 1 NEMA 3R SERVICE SOLAR STICKERS D w RATED LOAD CENTER W Z ; ryk EXISTING EXISTING DISCONNECT I., III Q LL 5/16•R 4•SS LAC BOLT 200AMP Q ❑ lz m W/SS EPCM BONDED WAA1ER UTILITY PANEL IN MAIN BREAKER=60A U -3 U D METER HOUSE (3)2 POLE 20 AMP li BREAKER p E.tt� w zpoQ �Pje OF New i TTf SYSTEM SIZE: 14.99KW ,-I,o ^5 E9" 0 D O'nm t ' S ¢ W= 'a Oz; N m BI N N m = f w QV m oW¢va A 6 ao` � n i D'OP SSIO35iONP�'� z f z J Lk = gj1 6 Z ❑ ❑ N ; � 0 ❑ Wo _ Wr �m �❑ SIGSBEE RD U Q m o in TRACY JOSEP LI.I ❑ N �� z ❑ Q 1330 SIOSBE FIR T rrnn r �17�� m MATTRUCK,NV,119 f�E UJ p o PANELS 3 s U EDT .., Z U p 2T �y Y e(Y LL N 6 r x 8'ROOF DRIVEWAYU a = RAFTER CD 16' - 3 2,x O.G. .. tt; m SEG-405-BMD-W OD-G� .er:... � IL W Z 405W SOLAR MODULES u W En ®Y thlba�D RAL �u alw M Yf} k E3 Q ss W.w ATTIC - uf.far �rs� 0 f m o ♦ W W BMW ISRMLT waF Sitars z s I UaE>s)ON 151 mom FNIER ON J 00 0 U 1/f Pumm gumtl 7'-6 3'-1 7'-11 W U Q z SPAN SPAN SPAN ROOF CROSS SECTI❑N Q J SCALE 1/4'=1'-0' CP,VEWAY m z r _ z m 0' o o w o ❑ En ROOF PLAWPANEL LOCATION Z w SCALE 1/18'=1'-0' INM Q Q ❑ ❑ N z N ❑ ❑ En � N � N F Q N o m W O Z z � m a ❑ � o 0 F PRIOR TO CUi1111G OR ORDERING OF MATERIAL.OR PLACEMENT OF THIS PROPERLY PRODUCES THE REWIRED GROUND LALLOF MOUNTING BRACOM SHALL GROUI�ACCESS PONTS ARE NON-OBSTRUCTED PER 2018 RIC AND zTHE L-FOOT ATTACHMENT,FIELD VQBFICATION OF EXXT RAFTER ACCESS TO THE ROOF ACCESS PATHWAYS AS DRAWN. SECURED TO A ROOF RAFTER. 2020 NEW YORK STATE RESIDENX BUILDING CODE W a o°nOF NF LOCATIONS ARE REWIRE TO COMPENSATE FOR PRED0S11NG RAFTER IRREGULARITY THAT MAY EXIST. m nZoo gr 1HFSE DRAWINGS COMPLY WITH THE 2018 IRC AND THE ACFUAL IN-FIELD ATTACHMENT TO THE ROOF WILL THESE DRAWINGS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE(AF k PA) NOTE, WHENEVER POSSIBLE PLACE m 2D20 NEW YORK STATE RESIDENTIAL BUILDING MEET OR EXCEED NYS RESIDENTIAL CODE WOOD FRAME CONS(. MANUAL FOR ONE AND TWO FAMILY DWELLINGS. SMALLER SPAN BETWEEN ATTACHMENTS z Iu w 5 °a&Iss o= POINTS TO AN OUTSIDE EDGE Ott o e w z i 9DFFs CODE REQUIREMENTS OPENING IN A RUN '3 "rf z z sio+ m n 40 z Z Z o Lin 11,0 p w❑ ARRAY INFORMATION W� O J❑ FAO � �„ aD oN J►4 - ah ATTACHMENT PENETRATION MAX MAX IN i �s ROOF PITCH ROOF AZIMUTH ROOFING TYPE RACKING TYPE FRAMING TYPE FRAMING SIZE O/C SPACING ATTACHMENT — ♦ ♦ m - TYPE / N PATTERN SPACING OVERHANG c ✓•T� 0 ROOF t 18° 328° COMP SHINGLE RAILED UNIRAC NXT L-FOOT WOOD RAFTER 2'X 8' 16' STACKED 64' 17' Z Q m9 ROOF 2 20° 146° COMP SHINGLE RAILED UNIRAC NXT L-FOOT WOOD RAFTER 2'X 8' 16' STACKED 64' 1T W m o 0 Q � IN �� D m qZ m � - s TABLE 2: PENETRATION GUIDE FOR INSTALL FIGURE 3: MOUNTING CLAMP Z W m Y POSITIONING DETAILS Z m In LI — [] o TWO OR MORE ROWS OF MODULES BOM > m c 17" 17" Q ? J ® UR-40 RAIL END CAP 32 PC. Z u o J J D Q (] H ARRAY SKIRT 100 Ft. J [1 Q N O I ! ARRAY SCREEN 240 Ft. STACKED STAGGERED ' co Q P Z z SIV SERIES 405W; 7 n H SEG-405-BMD-HV t O W IL (67.80"X 44.65") . . PHOTOVOLTAIC SOLAR PANEL 37 PCS I o p In LI (see panel specs for more 1- O 7 N • detaiIs) ' (0 I J L W INm Q Q 0 Z _ N O O II] W MID/END Clamp 90 PC. I N _ F N y a FULLY STAGGERED > 1 O m 1•, O ONE ROW OF MODULES 16 PC. F m a N/ WIREa D m m MANAGEMENT MENT CLIP s 17' 1 17• m I Wire Management Clip 52 PC. w an,,a P.jsOFAlp SEG-405-BMD-HV °o D ^m ..• Tz 91. FULLY STAGGERED STACKED/STAGGERED w oia o g MLPE&Lug Clamp 45 PC. •RAILS SHALL BE POSITIONED IN THE NON-CROSS a of e",z MAX. *CHECK TABLE 1 FOR .PENETRATION SPACING AND PENETRATION PATTERN HATCHED REGIONS FOR EACH ARRAY. o n w z -'v i Z FssloNP� m a aU > H O z z LEGEND Pic. cowko 425 Ft. W W O m ED r n.. 37k a m Z m C h aQ DN s Sa � � m va ge n I I Ii Q N ° J n> IL W IL �z Z w W fC al in L3 a , 0k 3B' EXISTIG M PIPE LL Q n EXISTING ENT PIPE D o EXISTING VENT PIPE V- El W NOTE:THE ROOF WLLL HAVE(21)(MG-40541MD-NV)405 WATT PV MODULE PANELS WITH KW OUTPUT SOLAR PANEL LAYOUT#1 (p 0 OF(8.505 KW)AND(21)KXPLUS-72-2-USMICRO MNERTERS. scALE oa.ro 0.ldge Z B'Mn VeM Nee 1X ISTING VEJMT PD'E m d 0 Q (A p w IL Li kQff o ❑ U7 a mk wT ° Z m � w o N Z D ° N p ❑ N I N w N Q � 1 O m 36 EXIST G VENT ^ � M�, EXISTING IT.AWINING W Z 3 � m a 3-0 Oa 7 ° Q NOTE:THE ROOF WILL HAVE(16)(SEG-405-SMD-HV)405 WATT PV MODULE PANELS WITH KW SOLAR PANEL LAYOUT#2 0 OUTPUTOF(6.480KW)AND(16)IOBPLUS-72-2-US MICRO INVERTERS. 4 U ti scALE,,e•.ro• � a a°of n m F Q n a 'ZE OF WF� a J.-n o 0� IL Y O'nm ai H �Vw m azoa I� f! '' 1'+i m nDIL 1 7 z 2 SIGSBEE RD D ° ' � iO o wo TRACY JOSEPH ;o 'm o 11 o RON1330SIGSBEER FOFT < � oN MATTITUCK NY, 11952 PANELS 37 HOUSE J J N •�� Z m h IT a o w a re MM. ■mU ,s Mir. ❑ � ° Q N P PD N G J m J 3 DRIVEWAY Z a Z m z W ExI_r,NG VEn- Q W m Y pJ n p 0 7 d mF N p LCCAnCN OF EILCTRIC METE �+ U a W ANDAG DI9DONIJELT a J J Ir N p ❑ Z ¢ w q] —S GNIEv ul W 0 u, J 0 ti 13 NG MN E*Isn NG ROOF AMYIIHG U Q m F W o E%I-NG— PIG L J m14. a r Z z ,STING v T m a ❑ o w °o ❑ EnEl F Z to W m = a N 0 0 Z m Ex.E.vG'EI. N o 0 N Q N _ w m w Z z W � m a GB'Mm. a ❑ � m DRIVEWAY -3 0 x ° a Faoa rtEOF JNVp .r .i ❑ Jf n a r-b m a> °a o m p z P a mm Q C •W z Z Q ❑ WF-z s,ONP�� p Z z m N ¢Ua > ❑ Z z 11-- SOURCE44 POWER MGM a PRO NEC 690.31(G)(3x4) W TURN OFF PHOTOVOLTAIC [0 ELECTRIC SHOCK HAZARD �❑ u m °o o°a I• V °n CONDUIT LABEL(1)PER 10 FT ^ AC DISCONNECT PRIOR TO TERMINAL$ON THE LINE AND a m a In ���/ D b W • LABELS SHALL APPEAR ON EVERY SECTION OF THE Z O WORKING INSIDE PANEL LOAD sm[s MAY BE ENERGIZEDN .liYr = o,°• Z WIRING SYSTEM THAT IS SEPERATED BY m IN THE OPEN POSITION tiT� c c c O Q ENCLOSURES,WALLS,PARTITIONS,CEILINGS,OR NEC 110.27(C) NEC 890.13(B) `m FLOORS. ' �� •a ID. i 101 of1 1 • NIs N MAX AC OPERATING - W 44.77 • ' • DISCONNECT ' � NOMINAL OPERATING VOLTAGE: E NEC 690.86(C)(3) WIIESS - Ey • SHALL BE LOCATED ON OR NO MORE NEC 690.13(8) Z NEC 6W0.64 THAN 3FT FROM THE SWITCH U a u W u Li w D O V AWARNING 0 n H Q 6 ELECTRIC SHOCK HAZARD POWER SOURCE LI QK TERMINAL$ON TN[LIN[AND OUTPUT CONNECTION. ly OLowDSIDE$MAT B[EN[ROIZED DO NOT RELOCATE THIS QD: IN THE O►EN►O$ITION I F OVERCURRENT DEVICE. J U J ' , NEC 690.13(8) ❑ z m w NEC 6DQ73(B) NEC 705.12(B)(2)(C) J o 0 0 Z ❑ a w m � � O _� z O `2 • • 1 Q F ELECTRIC SHOCK HAZARD R,> C O F 1 1 TERMINAL$ON TH[LIN[AND i Q LOAD$IDES MAT k ENERGIZED Q CAUTIO 0 m Z ZW IN TH[OKN►oeIT1ON O • (` _ z ZMULTIPL — ,� POWER TO THIS BUILDING IS ALSO a N ASIL O AWARNING E SOURCES OF POWER d OC ti SUPPLIED FROM THE FOLLOWING 0 oSYSTEM 0 to Z �„� TURN OFF PHOTOVOLTAIC Z W SOURCES WITH DISCONNECT(S) m = o o AC DISCONNECT PRIOR TO BIRDS Q O 44.77 Q W Z40 WORKING INSIDE PANEL O Z LOCATED AS SHOWN: 0 N ❑N N ❑ 'n N a Lo w N J ' NEC 09&54 NEC 690.13(0)3 110.27(C) U) N 0 z m W PHOTOVOLTAIC w Z 3 Q� SOLAR PVSY5TEM EDUFPED ARRAY ON ROOF 1 0 m m WITH RAPID SHUTDOYM A WARN I N G f - f TURN RAPID ELECTRIC SHOCK HAZARD SOLAR LOAD c NBC690.56(C)(3) eWlrpl a DOWN TERMINALS ON THE LINE AND CENTER/DISCONNECT i ` D° W • SHALL BE LOCATED ON OR NO MORE •oPP•PCStflCN LOAD SIDES MAYBE ENERGIZED m zO°o ` THAN 3FT FROM THE SWITCH TO SHUTDOWN IN THE ovcN►osmON F f Is i 'Sg OF Al w SVSrEM AND UTILITY METE <_ '--O°o Ic }p Wr R®UCE NEC 690.13(8) o ¢>o SHM HPZPR , r < <Z0Z C N PA2AV c AWARNING DUAL POWER SOURCE D CR 0-6 W SECOND SOURCE IS PHOTOVOLTAIC SYSTE NEC 690.56(C)(1)(A) MAIN SERVICE o i.7 a4 eeyljy r SHALL BE LOCATED NO MORE THAN 3FT PANEL O,n> FSSION,`�� NEC 705.12(8)(3-4)3 690.59 FROM THE SERVICE DISCONNECTING MEANS TO WHICH n pDi o THE PV SYSTEMS ARE CONNECTED. 1330 SIGSBEE RD = W❑ ❑ F O O ❑ O HORIZON t m 0 M mass U N I RAC W aU. oN Jb BETTER SOLAR STARTS HERE o_ a m Z B DISCOVER YOUR NXT HORIZON 6"d7AitP _Qi "` N + �m o �` 1 ' WNWWW CMsWr+krvrwe�ow+�e ••, a •=0 The culmination of over two decades of experience.Thoughtful design, ,macaw, N rigorous engineering,world-class support,and a reliable supply chain are theP o foundation of what makes us confident that NXT HORIZON is the NXT level "" "" z = W Z of DESIGN.SIMPLICITY,and VALUE. '� N 7 N FF flf� war" LJ m Q I�SlCIIMDI rrsra+rWtaasaftftis5 Q _f w MU 9itiMFYi tor..;. Q � N Q tMw►ratwrMM.wria�n.es :f.s wth fad t�f��a taP rat U >fh.ncYdrattrtie�mcr'.�::L wladMdisµ J Z a w rn J 7bd�ItfltLia'sa':. M/tfMYr�t4f�drw U3 J C � ❑ -. bIYMWtfrYie�t C] Q m I- hrwtlret�ritfnlraf�d ❑ ��1 dAw+fllofa J Z F H J m Q l` Z Z m a o It m ❑ w a. ICf IIMItx W ttl![WYItBIFtt tP(t► ❑ ❑ En U br4re�eW�#nIL+Dn+tkttfatw Iwtlt l6Ntit MU1 N Z Wt6W tii-bre4f tyrwr iBMYr 4 � NO ❑ _ E 47tNYtVtiYONIR� raYfi�fM retnnyte�f N } ' Q N1�tt m 0 utl: w Z 3 N �k MddaMtMtMMatWf"M WNORM WX ow SMwM'"Yrs 0tM46MMIM IbPftU6 p1YP M111N1�t�YYMWt�I tMP �II�WtIMpYtMMMtt ❑ '] O p ' 00ft aMun rffr�eianar "►" Q rwrw.m�.n. bk*" fttrW.trf.M t3ttlPfl rwftx►ar wDOW O tn*d".ft'"em " wfu:n.fftrtffwrfitr� AmAmk dkfrlaorrr2Wloftit ❑ W itiOblfWlottM f+t twMfftt"MtM MM""GIAH M`#Y�tyltgMNNWft'tl 1"It(tI MEO"DIY ifWNMSW"a' W tUfltl� uww w+As-aw Arfeu+tYlpntt mriRMtx. Nb tAnrn�fY tit tl� Mt iMw4YtL44t1arMitP it rfn twrmtrawlttfa.�.a"Inw_ ''t IL •wr � ��� tkttit�"ftttYfMti IMI"tltt�l�p>1Mr"rCt- YJ LLJ ` ❑ > ❑ Q ALL NXT HORIZON DESIGN FOR QUESTIONS 1' CUSTOMf1 1' Z w () o ❑ ❑ d❑ oS E'_ SEww . ww G SOLAR INC.(SEG) SEG SEG SOLAR INC.(SEG) 7❑ o 0 -11 o 8. w.Segsolar.com S O L A R w.Segsolar.com [0 in in j _.. ❑ J N j Z pC n Electrical Charaeteristkes i j a o ®® __ w m z• L> Z _ .01 STC NOCT STC NOCT STC NOCT STCNOCT 0 Ul Z Maximum Power at STC(Ping) 405 304 410 308 415 311 420 715 ly H �a Ot0 oven cirpan Whig.(V..) 7722 3473 37.32 3481 3742 34A0 37.52 34.99 yy a U 14 51V SERIES In Short Circuit Current(Isc) 13.70 /I.07 13.80 71.75 77.90 11.27 1490 11.32 W In Maximum Power Vahage(Vmp) 3093 2891 31.05 29.05 31.16 29.19 3128 29.33 '` I•`• -�_ LU) ; Maximum Power Cunenl(Imp) 13,10 10 51 17.21 1059 13 32 10.66 13.43 10,74 t J 2 W Z Small Changes, Accomplishments Module EMdencyet STC(gm) 20.74 21.00 21.25 21.51 Ar V W W to Y Power Tdsnno (0,sJ%) . O / / ry _Maximum Sptam Vobge 1500V DC --_----------_�_ rQ � in� Maximum Series Fuse Rating 25A LL Y ❑k U n C W STR artllwu:as 80WrM amcb Nmgenfun 2SC AHhrS �, ry M — J P.—Irreasars»amW/m`ambYnl tarrpe..lure 9'C moW4remperelun 45'C wiM aveed 1Ms Li Power maaevremanf rol.rarce:vr% Temperature Characteristics /i, ([ r O o W w U1 Pmax Temperature Coefficient -0.35%I°C ur J 0 a ❑ L` H Voc Temperature Coefficient -017%PC e_d� sw osnae L) Q Cli F r Tr ac Temperature CceMcient eoa!i%rC I W ❑l a.f defun Operating Temperature 40-85•C 7iMrbS® A4nuN ror braaa ` Nominal Operating Can Temperature(NOCT) 45t2•C •SIV SERIES o PRODUCT CERTIFICATION Q IEce+2+a:ga+a lEe eneozo+e;uunoa uul7arvcaucEc Mechanical Specifications VCufVB m Z SEG SolarlNC.(SEG)r•definadnu high-efec-cynotlule eadea by .—.--___ _- _ its tin 182mm silicones stars with mulibusbar and hatkut cal IEC8290a ii E[temal Denims— 1722.1134,35 min Cco ` Z technologies.SEG panel combined creative technology effectively IECe211e Ammonia aenmme VJaryhl 21.5 kg — Q uJ F and extremely improved the module efficiency and power output. IE09008a put and 9ana Soler Ceh PERC Mono 106 ❑ W R IEfA1215 Neewme(25mm1 ( pcs) "e•TYIw(u1e173oi:taa(Tpe1JlV Typso"o)) Front Glass 3.2/min AR coating tampered glass/low iron ❑ ❑ UJ (Cj *-KEY FEATURES souoo1:201a:190te012013:I6o4a0o12me F O Z n Frame Black modk alum inium minium anoy 1 = J W OLeta mismatch to get more power Ca �w CE ® Junction Box IP68/7 diodes N m Q ❑ ❑ ConnedorType MC4 - ❑ N Z _r� Less power loss byrnmim¢ing the shading impact u INSURANCE Cable Type/Length 12AV4G PV Wire(ULAEC)11200 mm N ❑ � W W P'Cr Mechanical Load(Front) 5400 Po/113 par ® Competitive low light performance v N > ' Mechanical Laad(Rear) 3800 P. psf > 0 o WARRANTY 'Pas.,ro sEGi.wadaan Manuel b.dar.M co 0 W 3 times EL test to ensure best quality .aveY. tww Z Z �k Packing Configuration a ® Ideal choice for utility and commercial scale projects ass Q OMIKE m by reduced BoS and improved R01 104 Container zc cv +phe i -3 ❑ QOutstanding reliability proven by PVELfor Pieces par Paget 3• 3' sbingent environment condition: saw5 �c +e m a Pallets par Cadaver �^ Pieas per Caltalnar Ise 1i6 0 I.I •Sentl,acid salt and hailstones LJJ •Antr•PID 25 26 =�oN...gym Fadeeala,q•aeepneun SEG. om.aa�,aa� ameta � w aeo SEG SOLAR INC.(SEG) sec SEG SOLAR INC.(SEG) m 0 �..—cwr�na nit a waromnes a site as rncswsee a .c.n,mamk.ezaasm..�.uwea sea 0 > Q sees..wmia,Tw .u.s:s.ee.wewa....rswe�om sec s.�en,ee.*a T.i azs.esnsew++ w <<.m ❑ ° O W❑ ENPHASE � IQ8 Series Microinverters W 3 o '0 a o 0 T r U h I JO1 O� = z jh N Z x n Commonyusad module palm 235 gs2 W -]50235-440 •280-460 •295-500 320-540• 295-500• I,gJ n y' Module whpatibility 60.ca111120 had-ce11 60-PlIV120 hancall,66-caIV132 hell and 72ce11144 halftel CJ t0 t MPPi voitape Hoge V 27-37 28-45 JS-IS 38-45 38-45 38-45 /W/Y Operating range v 25-48 25-58 MiMmx stad voltage v 30148 30/58 YJ C< ? Mex irput DC voltage v 50 60 z Max DC cunenl3(module Isc] A 15 — In W m Or—Mge de.s DC pod II L DC part backfeed current mA 0 PV army config.robon 1x1 Ungrounded arty.No additional OC side protection required;A.0 side protection nqums me.2OA per branch ckwil LI.IL = W Z W W W m 31 Peak output power vA 245 300 330 366 384 366 In fl L7 Z 0 B 7 Mex continuous output power vA 240 290 325 348 38g 360 7 n F Nominal(L-L)voleg.kil v 240/211-264 2081183-250 N p Q Max Pintinuous output current A 1.0 1 21 1 35 145 1 53 1.73 Q A f W J Nominal tequanry Hx 60 f N Q IQ8 and IQ8+ Microinverters Extended tequenryrang. H7 50-68 o z W U) AC shod circuit Isuit current ever 2 4/ ��t W J Our newest IQ8 Microinvertera are the industry's first miaognd-forming,software defined Easy to Instill AC cycles Arms En J 0 mrroinvedera with split-phase power tomersion capability to convert DC power to AC V .Lightweight and compactweh plug (Li)branch Mn units per 20 A( branch dreul5 16 13 11 11 10 8 V Q N power efficiently.The brain ofthe semiconductor-based microwerter is our proprietary pay wnnestore (- application spedllc integrated circult(ASIC)which enables the microinverter to operate in Total harmonic distortion <5% W ❑ grid-tied or off-grid modes.This drip is built in advanced 55nm technology with high speed •Power Une m Comunica0on(PLC) J Z digital logic and has superfast response times to changing loads and grid events,alleviating between components Overvoeage doss AC pod w L constraints on battery siting for home energy systems. .Faster installation with simple two-wim AC port beckleed current mA 30 I- cabfmg Power briar saming 1 U J Grid-11ad power rector(adjuetill 0.85 kadl°g-0.is 111bp Q obility Nlghucepower wn when Y m Z a'aP•c. Peak etndenry 975 978 97.8 97.6 81.6 97A :� Z •Produce power even when the grid is 11 a 0 down' CEC weighted eNlcbnry Y 97 97 97 87.5 91 97 11 (n •More than one million cumulative hours Nighttime power consumption cow 60 ❑ W d Part of the En ose Energy of tesbng ❑ �• d' ph gy System IQB IQ8 Series Mlcroinvertera redefine O L] Series Microtrwerters integrates with the reliability standards with more than one •Class II double-insulated enclosure cry AmbkntterrpereNreranpe ♦0°Cto•80°C(�0°Flo•NO°F) � Z W in IQ Battery,IQ Gateway,and the Emphase million cumulative hours of parer-on •Optimized for the latest high-powered Relative humidly Hope 4%tot 00%(caneensingl [*1 m -J W App monitoring and analysis software. testing,enabling an industry-leading PV modules N Z limited warranty of up to 25 years. DC Connedy orpe MC4 N N ❑ Mtdrogrid{ganln9 Dimensions(H.w D) 212 mm(SX)x 175 min(8.91x 302 mm(1.2') ❑ En N H ® • p rt with the latest advanced grid weigm 1.08 kp(z.Je It.)sup 0 support Cooling Natioalc,m,d,n-no Runs N M W 0 •Remote automatic updates for the latest grid requirements PPPrned for wet lacaeona Yee Z Z •Configurable to support a wide range P.M.—degree PD3 H m Q Conned PV modules quickly and easily 108 Series Microinverters are UL listed Q ly m of grid profiles Endosure Cl... IIdouble-insulated,carmebn rasitlse rk errcbeln to IQ8 Series Microinverters using Me as PV Rapid Shutdown Equipment and p°None O 7 Q � included Q-DCC-2 adapt.cable with conform wah various regulations,when •Meets CA Rule 21(UL 1741-SA)and IEEE phig-splay Ii connectors- installed according to manufacturer's 1547.2018(UL 1741-SB Bd) Envion.category/uv e.pocun nthp NQ.p TyyaB/auMoor inductions. � Q Note CARule21(UL17413A),UL6210%1,UL1741eEEE1547,FCC Pon 15 Cities B,ICES0003 Clan B.CM(CSA-C22.2 NO.107,1.01 lee Nicroirrrenem cannot Sa mi.e°to9aMerw Certifications This product is UL Used as PVRapid Shut Down Equipment and canlsrms with NEC 2014,NEC 2017,and NEC 2020 ukides LL P--genemaons d Enphese micmlmeders(107 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown 0 PV Systems,br AC and DC wndudon,when metalled according to N r� senea lO6 S—ii..).n me.am.syn.m. 1°arwnccturer.Instruction(. W •OnN+hen inamrled Mimi 10 Staten Corar°Iler x,mesa UL 174f 1.L •SO6 end ID6PIu.ewp.A spldShsae,x4w inatell.eon.onM. (1)The 1081-1-208 variant will be opar dirg rn gW4,d mode Ony at 208V AC,(2)No enforced DCl4C ratio.See the compatibility calculator 0 Mps:/link.erphase.eom/modWecompellbild,(3)Maximum continuous input O m Q —22 Eryhe..En.gy.Ak hdrm resenee.Enpheae.me Fnphe.e lopo.lOa Nicmirrverter4 Oc coment Ru 10.a4(4)Nominal vollege range can be extended beyond,omnal if requi,d by tiw utifhy(S) end Omer name.en bed.mark.dEnph.se Eneg/.Inc.Dsterublenlochenge. IOaSp-1 1 -°067-OXEN-UX20221x-x7 1..,..Iy.Reerb local requirements to del the number of...imimt—per brand)Inyour area. IOIISE-DS-0001-01-EN415-2022-03-17 C\I Z NW LL U) t APPR VED AS NOTED DA • xx B.P.# FEE �� � D I� By 9 NOTIFY BUILDING DEPARTMENT AT 631 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTONd ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CONDITIONS OF VN.YSIC N ZBA N PLANNING BOARD N TRUSTEES OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE" OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED , DESIGN PROFESSIONAL'S CERTIFICATE OF COMPLIANCE To: Town of Southold Building Department Subject: Solar Panels at residence of:Tracy Joseph 1330 Sigsbee Rd, Mattituck, New York 11952 Project Scope: Installation of Solar Panels on Existing Pitched Roof Application Number: N/A I, Naresh K. Mahangu on behalf of the owner(s)of premises Known as 1330 Sigsbee Rd, Mattituck, New York 11952 submit the attached plans for your review and issuance of Building Permit for the project referenced above. Please note the following conclusion regarding framing structure,roof loading,and proposed site location of installation: Existing roof framing: Conventional framing 2"x8" at 16" o.c.with 7'-12" (horizontal rafter projection). This existing structure is defiantly capable to support all of the loads that are indicated below for solar photovoltaic installation project. 1, Naresh K. Mahangu , License No.089068, certify that I am a Professional Engineer,duly licensed to practice In the State of New York and that I have Inspected and analyzed the roof structure at the above-mentioned address and have determined the structure and the panel attachments to be adequate to support the new additional load imposed by the proposed solar panel system. The proposed system complies with the 140-mph wind design load as 2020 New York State Residential Building Codes and the 2017 National Electric Code(NEC) NFPA 70,and the ASCE 7-10 when installed in accordance with the manufacturer's instructions and standards. TABLE R301.2(1)CLIMATE AND GEOGRAPHICAL DESIGN CRITERIA GROUND WIND WIND WEATHERING FROST TERMITE DECAY WINTER ICE FLOOD SNOW ZONE CATEGORY LINE DESIGN SHIELD HAZARDS LOAD DEPT TEMP. REQUIRED 30 140 B SEVERE 3 MODERATE SLIGHT TO 11 YES NO FEET TO HEAVY MODERATE DESIGN LOADING R301.4 AND R301.5 AND R301.6 NET DESIGN WIND PRESSURE-ASCE 7-05 ATTIC W/O ATTIC W/ ROOF NO ROOF W/ RAFTERS HAVING RAFTERS HAVING ROOF 0 TO 7 DEGREES[•33.0] STORAGE STORAGE CEILING CATHEDRAL SLOPES GREATER SLOPES GREATER ROOF>7 To 27 DEGREES(-56.21 LOAD CEILING THAN 3/12 WITH NO THAN 3/12 WITH FINISH CEILING FINISH CEILING ROOF>27 TO45 DEGREES[•30.4 ATTACHED ATTACHED LL=10psf LL=10psf LL=20psf LL=20psf U180 U240 DL=10psf DL=20psf DL= 10psf DL=15psf OF �gH K. Very Truly yours, �a 12/05/2023 Naresh K.Mahangu Signe .o O Date New York State License No.089068 �O�Fv S�S I CJt`1 p� S&R SOLAR DESIGN 4 15 METROPOLITAN AVENUE I KEW GARDENS,NY 11415 PHONE:646-626-6299 i FAX:(516)210-0141 FILING@SRSOLARDESIGN.COM SOLAR INDIVIDUAL PERMIT PACKAGE SATELITE IMAGE CODE INFORMATION o o k jr 14.99KWGRID-TIED PHOTOVOLTAIC SYSTEM _* APPLICABLE CODES,LAWS AND REGULATIONS -� C) ° m E t 2018 International Building Code(IBC)/2020 BCNYS Q F co z ��� - * N •' s �,;�+ 2018 International Residential Code(IRC)/2020 RCNYS w D > a m HOMEOWNERS NAME: �I�I 2018 International Fire Code (IFC)/2020 FCNYS W O N ®; Z 0 " T RACY J OS E P H 2O17 National Electric Code(NEC) � � � ��� o 2018 International Energy Conservation Code(IECC) /2020 N > + ECCCNYS 'a = elf �' GENERAL NOTES - a Z 0 PROJECT LOCATION: t J� I SOLAR PANELS WILL BE (37) SEG-405-BMD-HV 405W PV MODULES, AND (37) N o (_ Lo IQ8PLUS-72-2-US MICRO INVERTERS Q Z I 2. PROVIDE A.C.DISCONNECT: 240VAC,NEMA 3R. in Q (917) 975-4453 3. THE AC DISCONNECT WILL BE LABELED AS "UTILITY DISCONNECT AND 3 ID PHOTOVOLTAIC SYSTEM LOCK-OUT"LOCATED WITHIN VIEW OF THE ELECTRIC UTILITY W } 1330 SIGSBEE RD s METER. = W Z .+M......: 4. IF IT IS NOT PRACTICAL TO LOCATE THE AC DISCONNECT WITHIN VIEW Of THE � EL W� NW m Y MATTITUCK, NY, 11952 UTILITY METER, THEN A WEATHERPROOF PLAQUE SHOWING THE LOCATION OF THE SWITCH MUST BE INSTALLED WITHIN VIEW OF THE ELECTRIC UTILITY METER. � (1] U A' 5. ALL WIRING TO MEET THE NATIONAL ELECTRICAL CODE. Q UI F- IL �.. 2 Ile+ 6. THE RAFTERS AS INDICATED HAVE BEEN ANALYZED AND DEEMED SUFFICIENT TO )- s SUPPORT THE ADDED LOAD OF THE SOLAR PANELS AND CONNECTORS. Q U P3 Q r\\, TOWN OF SOUTHOLD • , ,,,; " 7. THE SOLAR PANELS MAY NOT BE INSTALLED ON AN EXISTING ROOF THAT HAS � MORE THAN 1 LAYERS OF ASPHALT ROOF SHINGLES, UNLESS ADEQUATE MEANS OF l— U3 UTILITY: PSEG LONG ISLAND ~ .. SUPPORT ARE PROVIDED AS PER THESE DRAWINGS. W (n IL 8. THE MAXIMUM SPACING BETWEEN THE STANDOFFS SHALL BE 64"O.C. F_ W In ♦. �"— Z a W 9. THE SOLAR PANEL MOUNTING SYSTEM WILL BE BY UNIRAC NXT SYSTEM. W O Ln J o U 0 ATTACHMENT DETAIL LINE DIAGRAM SHEET INDEX U Q UJ � w o J Z PAGE 1 SITE MAP-LINE DIAGRAM - DETAIL I— J PAGE 2 Q ROOF PLAN & CROSS SECTION U STRING 1 (CONNECTED TO PV MODULES) t` Z Z a) Q. 0 PAGE 3 ARRAY INFORMATION AND MOUNTING DETAIL 0 W a �„ STRING 2 ( CONNECTED TO PV MODULES ) 00 5/16"-18 x 2" SERRATED FLANGE HEX SCREW PAGE 4 m = J Z W I� �I STRING 3(CONNECTED TO PV MODULES) ROOF PLAN LAYOUT Q Q p x, PAGE 5 0 0 UJ SOLAR PANEL LAYOUT d N W 4 3A6 to 3 7I6 zL3/6. } > Q HEIGHT ADJUSTMENT s� NEW SOLAR AC 125A PAGE 6 N m O NEMA 3R SERVICE RATED LOAD CENTER SOLAR STICKERS w Z 3 EXISTING DISCONNECT EXISTING m Qit 5/16"x 4"SS LAG BOLT 200 AMP Q D m W/SS EPDM BONDED WASHER UTILITY MAIN BREAKER =60A B Q � METER PANEL IN O -3O 3A" HOUSE (3) 2 POLE 20 AMP BREAKER 3✓" Z Q O ❑ O m OF N IV TOTAL SYSTEM SIZE: 14.99KW a � 0 S P�SN K. Y 0 0- ) O9 U ❑ IL} o 92 j 49X6= N D Z 0 C Q aNN Z N IQ C7 W Z N � w 2 p W ul O 0 >- O�FSSIONPI m V IL y N 0 Z r L` Z z 0 0 N 0 0 WO W 0 Do � D 2 0 � 0 t: 0 00 SIGSBEE RD L7 Q D Ln a N TRACY JOSEPH 1330 SIGSBEE RD FRONT rn ���'� w m MATTITUCK,NY,11952 HOUSE UJ o ° OF PANELS 37 m i C. Q I m 4, �.. 0 Q z O z In L9 z 2"X 8" ROOF DRIVEWAY U m I RAFTER @ 16" �y` 4 2' X8' RI O.C. �/ 0 �- 10 BONDING SEG-405-BMD-HV END-CLAMPT�NGFE�G�GNE ER Z Q w Z`'5/16'-1Bx 3" sNDAG ogCONNEG W , Y 405W SOLAR MODULES " T" uNCE - NEx SCREW BONDING Q N In U O (D o MID-CLAMP v F Unirac NXT RAIL HEIGM."t.3 MENT I 6131n6^ Ez15 nG ninnc 7 N 0- 0f U m Q A-IT I C Udrca roa n,P,o ILL Q m " S.S. Lag Screw - - 0 t11 -- - N EXISTING ASPHALT ROOF SHINGLES W (MAX 1 LAYER) ON 15j BUILDING PAPER ON „^ E„ Z W 0 W f- � J Q 1/2' PLYWOOD SHEATHING J D U U . . U Q Lo 0 7'-6° 3'-1° 7'-11' W z SPAN SPAN SPAN —� RODE CROSS SECTION o J SCALE 1/4"=1'-0° DRIVEWAY m Z z Do a ❑ lt rn O W a 0 o 10 Ll ROOF PLAN/PANEL LOCATION 0 z w SCALE 1/16"=V-0" N I Q 0 0 0 N Z _ N 0 0 Li N F N Q 0 M W U w z 3 m Q 0 0 o Q PRIOR TO CUTTING OR ORDERING OF MATERIAL OR PLACEMENT OF — > ° THE L-FOOT ATTACHMENT, FIELD VERIFICATION OF EXACT RAFTER THIS PROPERTY PRODUCES THE REQUIRED GROUND NOTE: ALL ROOF MOUNTING BRACKETS SHALL GROUND ACCESS POINTS ARE NON-OBSTRUCTED PER 2018 IRC AND z a 0 N LOCATIONS ARE REQUIRE TO COMPENSATE FOR PREEXISTING RAFTER ACCESS TO THE ROOF ACCESS PATHWAYS AS DRAWN. BE PROPERLY SECURED TO A ROOF RAFTER. 2020 NEW YORK STATE RESIDENTIAL BUILDING CODE. W Q`n Ln Q �E of NF IRREGULARITY THAT MAY EXIST. °o a} 1, aul ^`�?Y�`'N K4yo9� m 0Zm m c THESE DRAWINGS COMPLY WITH THE 2018 IRC AND THE ACTUAL IN-FIELD ATTACHMENT TO THE ROOF WILL THESE DRAWINGS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE (AF & PA) NOTE, WHENEVER P❑SSIBLE PLACE m W Z ° o w� 2020 NEW YORK STATE RESIDENTIAL BUILDING MEET OR EXCEED NYS RESIDENTIAL CODE WOOD FRAME CONST. MANUAL FOR ONE AND TWO FAMILY DWELLINGS. SMALLER SPAN BETWEEN ATTACHMENTS z I w - q oe se Q•z CODE. REQUIREMENTS POINTS T❑ AN OUTSIDE EDGE ❑R ° N o 9�rFSSIoNPv�c`' ❑PENING IN A RUN. :1 7 a I z m N a a z z 0 0 - lO o w0 Cal ARRAY INFORMATION a 0) SW ATTACHMENT PENETRATION MAX MAX J J nj z o °n ROOF PITCH ROOF AZIMUTH ROOFING TYPE RACKING TYPE TYPE FRAMING TYPE FRAMING SIZE O/C SPACING N PATTERN ATTACHMENT OVERHANG 'J [� �►�I� w = SPACING — o W 0 ROOF 1 180 328° COMP SHINGLE RAILED UNIRAC NXT L-FOOT WOOD RAFTER 2"X 8" 16" STACKED 64" 17" Z Q N y ROOF 2 200 148° COMP SHINGLE RAILED UNIRAC NXT L-FOOT WOOD RAFTER 2"X 8" 16" STACKED 64" 17" O W • m Q w 0 �.. _ a z O Z Q Lo N • N ZZ LL � � 3 0 � FIGURE 3: MOUNTING CLAMP Z a W Z TABLE 2: PENETRATION GUIDE FOR INSTALL Z � w m POSITIONING DETAILS _ N 0 TWO OR MORE ROWS OF MODULES BOM } } or 17" 17"17" Q Q m W ® ® e e ® ® ® UR-40 RAIL END CAP 32 PC. Z '- � Ll Q z w In I J O U ® ® 8 8 ® ` B ® ® - I W 0 ARRAY SKIRT 100 Ft. r. l- A 0 KIA I I I ARRAY SCREEN 240 Ft. I J STACKED STAGGERED I Q l� Z Z SIV SERIES 405W: I oo a n SEG-405-BMD-HV It (n H I I (67.80" X 44.65") I O W rn tl PHOTOVOLTAIC SOLAR PANEL 37 PCS I 0 D {�, ' 8 8 ® ® O U (see panel specs for more Q Z N 8 ® ® ® details) I M = JQ Q Z p ❑N Q O e ® ® ® ' MID/END Clamp 90 Pc. N � - Q FULLY STAGGERED N 0 m Uj I r' ONE ROW OF MODULES = N/s WIRE 16 PC. , r m a of MANAGEMENT CLIP p m 17" I I 17" 0 Z > a o c o Wire Management Clip 52 PC. W Q,n Ln N 040 a �EOF,VF B ® ® ® B 8 ® ® 8 SEG-405-BMD-HV Ln o �5H K. , yo FULLY STAGGERED STACKED/STAGGERED ° a.r ,n a in OZ MLPE & LugClam •RAILS SHALL BE POSITIONED IN THE NON-CROSS a *CHECK TABLE 1 FOR MAX.. PENETRATION SPACING AND PENETRATION PATTERN P 45 Pc. c9 W Z — o HATCHED REGIONS Z Z ` 2 a FOR EACH ARRAY. o Ln w v Z) '6 0 N a Z OFFSSI ONP� m V a U } N O Z LL Z LEGEND Piece Count ❑ ❑ - ® U.l-c NXT L-Foot 100 Pc, W o - C====7 Dmmc N%r RaL 425 Ft.� W p 0 SN SERIES 4p5W: O � ] � � � ❑ 6J po%BH 65') 37 Pc ! R m Co O a p OTOVOLTAIC SOLAR RAVEL Z In 18'MIN.VENT AREA J } J OI p N .®. z ClN � , w m � U Lp ❑ W 36"MIN.RODE ACCESS L I F a 36"GROUND ALCE55 AREA 0 m LJ a a aRidge Line- -a -a �'-a - - -e 0 - Q z EXISTING UTILITY METER O Z N Z N Q SYSTEM 1'-9' HEI HT I Li Z a W 'N z'-I• Z W m Y to m U O oLl } o � 36" in. EXISTING VENT PIPE LL Q m ROct EXISTING ENT PIPE Q' Access 45'-9" SYSTEM LENGTH EXISTING VENT PIPE W z''" Cl l / z Ir J Q LL J 0 Ll Q U_ NOTE:THIS ROOF WILL HAVE(21 )(SEG-405-BMD-HV)405 WATT PV MODULE PANELS WITH KW OUTPUT SOLAR PANEL LAYOUT#1 U Q w OF(8.505 KW)AND(21 )IQ8PLUS-72-2-US MICRO INVERTERS. z SCALE 1/8"=1'-0" W _ J -41 Ridge Lin Z 18"Min. — z XISTING VENT PIPE d p Vent Area XISTING VENT It U o w a 1'-9' 2'-1' LoL� O u 13 4" r Z ul 11-4" I W SYSTEM 1._y, N Q O ❑ HEI HT -1, ?(NSEG-405-BMD-HV)405W m Z - ❑ Cq❑ p 1-9' r_�1 — N u, W F- N > > Q m � 36"Min, EXISTING VENT Q W Access Z oof EXISTING R OF AWNING Z as-1" W SYSTEM LENGTH , 73'-9 Q p tY m NOTE:THIS ROOF WILL HAVE(16)(SEG-405-BMD-HV)405 WATT PV MODULE PANELS WITH KW SOLAR PANEL LAYOUT#2 0 OUTPUT OF(6.480 KW)AND(16)IQ8PLUS-72-2-US MICRO INVERTERS. SCALE 1/8"=V-0" Q 0In u w Q u1 a IS OF At t` ❑ *0�Q,gN K Mq O 0 O^ in r ?P m (L Q m 0z r Q -N Z 2 FUlM - N W Z Lj I W w o 06 O�}� a N 0 ❑ m �O�FSSIOT1A��d D = z } N ❑ Z 4 z SIGSBEE RD o w ❑pLn `O w 0 m TRACY JOSEPH r U N 1330 SIGSBEE RD FR❑NT o m Z r�i ��� to to MATTITUCK, NY, 11952 ❑E _j 0kh � : H❑USE ❑ N + z o PANELS 37 ►��� o 2W - nRoof 18'Min. to Y Access Vent Area J o m U0 36'Min. a _ W LL Ground L Z Access O Q Z Q N rM N J rn i in Q J 3 DRIVEWAY w = ui z I W EXISTING VENT W m V EXISTING VENT PIPE U) m U O 0 LOCATION OF ELECTRIC METER U h7 Q w AND AC DISCONNECT J J Ul U (J Z w Ul J EXISTING CHIMNEY J O U ❑ EXISTING ROOF AWNING U EXISTING VENT PIP J ai -EXISTING VENT 11 LO f ❑ w a 0 0 LO o ° Z NN I Q w Z P7 EXISTING VENT PIPE ❑ N p O N lyLj O O N O m W Ld Z 3 �y -Roof Q 0 LL m DRIVEWAY Access o z > o ° Q 36'Min. fn Z N Ln w Ground w Q� Q ACE OF N:Access o co K. El _j4y�o O d} N LO OZm � m Q 1-m (p N 0W Z -- OJ 0 Z 2 w 10 88 O} Lin Z o Z �OFFSSIONP��� m Q as > N a Z z SOURCE F' a POWER p A WARNING A WARNING ❑ W 0 NEC 690.31 (G) (3)(4) W ELECTRIC SHOCK HAZARD o ❑ ° o 1• TURN OFF PHOTOVOLTAIC ❑ in W CONDUIT LABEL (1) PER 10 FT TERMINALS ON THE LINE AND Z tf1 N • LABELS SHALL APPEAR ON EVERY SECTION OF THE AC DISCONNECT PRIOR TO Q 0� p .�. a Z O LOAD SIDES MAY BE ENERGIZED J ► > WORKING INSIDE PANEL J N . Z o WIRING SYSTEM THAT IS SEPERATED BY Z IN THE OPEN POSITION ❑ iPTA� w ,n O ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR ' m ° W 0 FLOORS. ' ���� NEC 110.27 (C) NEC 590.13 (B) m ; I @ 0 DISCONNECT — • • • • RAPID • z in WMAX AC Lo • • - 4477 • • � PV SYSTEM rnZ NOMINAL OPERATING 24� NEC 690.56 (C) (3) W 3 w/ • SHALL BE LOCATED ON OR NO MORE NEC 690.13 (B) } 10 Z NEC 690.54 THAN 3FT FROM THE SWITCH U a w z W —I (J A WARNING OWARNING o 0 � O -3 N - Q A ELECTRIC SHOCK HAZARD >- ❑ POWER SOURCE �/ U QN\5 TERMINALS ON THE LINE AND OUTPUT CONNECTION. Q mLOAD SIDES MAY BE ENERGIZEDDO NOT RELOCATE THISIN THE OPEN POSITION O 92 , • OVERCURRENT DEVICE. J In Ll mmil Q Z x W [fJ NEC 690.13 (B) NEC 690.13 (B) NEC 705.12 (B)(2)(C) w pa Q 0 J U U Q U Z W ❑Z U. O •I •1- A WARNING ___�"" ■ OELECTRIC SHOCK HAZARD HTERMINALS ON THE LINE AND Q Q Z W . LOAD SIDES MAY BE ENERGIZED O r ■ Z IN THE OPEN POSITION ❑ a 0 Z - CAUTION JWER — J POWER TO THIS BUILDING IS ALSO • � rn i- O Z - A WARNING �C ti SUPPLIED FROM THE FOLLOWING OF 0 W a. pSYSTEM a cl cn U TURN OFF PHOTOVOLTAIC m T 0 Z W Z AC DISCONNECT PRIOR TO z W SOURCES WITH DISCONNECT(S) N z 0 W 240 IIIIIIIII WORKING INSIDE PANEL Q Z LOCATED AS SHOWN. ❑ N _ NEC 690.13 (B) & 110.27 C 0 IT NEC 690.54 ( ) Z N } m > O W ❑ PHOTOVOLTAIC Z z SOLAR PV SYSTEM EQUIPPED �- m Q • WITH RAPID SHUTDOWN A WARNING ARRAY ON ROOF 0 0 0 0 TURN RAPID ELECTRIC SHOCK HAZARD SOLAR LOAD NEC 690.56 (C) (3) SHUTDOWN TERMINALS ON THE LINE AND CENTER DISCONNECT Li ❑ SWITCH TO THE Q H W SHALL BE LOCATED ON OR NO MORE OFF"POSITION LOAD SIDES MAY BE ENERGIZED In Z N 0 w THAN 3FT FROM THE SWITCH TO SHUTDOWN IN THE OPEN POSITION • F 7 G �P`E OF�F� W PV SYSTEM REDUCEAND NEC 690.13 (B) UTILITY METER o a^ N °o ^SP�tis� K A4q, �p--+ � SHOCK HAZAR In a> a IN ARRAY m Z m AWARNING DUAL POWER SOURCE Q 1�-1 N m m W SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 690.56 (C) (1)(A) MAIN SERVICE z W ° �A 0 • SHALL BE LOCATED NO MORE THAN 3FT PANEL N D o m 9OFFSSiONP���4 NEC 705.12 (8)(3-4) & 690.59 FROM THE SERVICE DISCONNECTING MEANS TO WHICH 1330 SIGSBEE RD m v a THE PV SYSTEMS ARE CONNECTED. > N ❑ z � ' Z • . w °❑ ❑sPUNI - w ❑ � m wasUNIRAC ° ❑ � � o RR> HORIZONQ Ln pm, °z in J��� Lh 1 o Sir a BME• • W J p J N : 'z o N W Sir w Z o ° _ = w DISCOVER kX7 1+9�9mx CM 30 ruyr U! � >YOUR NXT HORIZON _ 4 z W Z 0 0 The culmination of over two decades of expo riww . Thoughtful design, �� `�'"' � � � z rigorous engineering, world-class support, and a reliable supply chain are the ��� �. � r 9 � � Ilotindatlon of what rrN)kes us conhdent that NXT HORIZON' is the NXT Level MA '" Z d Z o of DESIGN, SIMPLICITY,and VALUE. � � w U o LO -1 �rw Im C" Q � w � no"S✓�IM�'34 m U M Q W �t+fM r �enotMrMr bdmecis Gt'Iti1 U) Q Q N U cK#r�tuiert a rtlM E �ppl ""� z M W Cp A#1 Ili+a�1 0 W_ U Q 0 Mtge TMr M+iM dAR J 0 -..1' rti�MMiMtral+K�ri U Q q] tRNpM 1�r ar�drlr hd 3"ada[�� W ❑ J Z L I � .J Q W I` IL Z co a a It U) F o W a Nnll�lZAll PlRE tAAI,AvEMT11'<Word o n ❑ Z w W Aaae�c�el+�rarT�+vR+;tb►1#ar>� ��1;� o wt I A9eM1 a N Z C) 51ra+�W40W I a�r►::tq�w � N ❑ � n room itN'l b mat otom d N — FW- I14,09 O AtIACHVII1K11 W4*kV*Wwrt44M,7 tiers N Q t r a m W w Z 3 atlMOfinq R.1111 SA°v < 0 Q m Ml(f Wilow VIP(&too CLWP atwNtiolk mot mAr*AcfW(WTctIP 101OW1104 WJA SOUTHMW U Ri SPE(?m!1 WiMAGEA+I+pi aiwlrrwtTptoe WOW ONAMM O ,.r ,i s$idrT► 1 nlraett r�du terms offm a eft M W Mod•arowk 4s*Ak so M 7 Y Ill,wh a �A1iC.'�i �r tr er tie 11"f t wlr,wwb* +w►+"I ON ur1tl Ao ft AWA 1460 1*Nr 6101APA O W W �aww® A N4 x a* Pv wra ftow,�r^n' wh tow.M can 6 M 1*1 %soft 404 tr me it imc°V 0ra �Mrry��r�e 11��t�rdwe w�a�pwldr I-- W � W Om 0 7 5 ❑ O p w ❑ w a m 7 SEG SEG SOLAR INC.(SEG) SEG SEG SOLAR INC.(SEG) p o 0 S O L A R www.segsolar.com S O L A R www.segsolar.com F CO Z N ��� n D : : a In O _J N .®. Z Electrical Characteristics W �' ,I _ L m n. i O Moduler: _ W � > _ m@ STC NOCT STC NOCT STC NOCT STC NOCTj' w 0 „ UJ > Z Maximum Power at STC(Pmp) 405 304 410 308 415 311 420 315 "" p z Open Circuit Voltage(Voc) 37.22 34.73 37.32 34.81 37.42 34.90 37.52 34.99 U N 0 N RIES Short Circuit Current(Isc) 13.70 11.07 13.80 11.15 13.90 11.23 14.00 11.32 ,.a"�" '.°Stn",... a 0� _ Eo a Maximum Power Voltage(Vmp) 30.93 28.91 31.05 29.05 31.16 29.19 31.28 29.33 SIV SE rn 3 .�.., uJ O m Maximum Power Current(Imp) 13.10 10.51 13.21 10.59 13.32 10.66 13.43 10.74 Ili >Small Changes, Big Accomplishments Module Efficiency al STC(rim) 20.74 21.00 21.25 21.51 " J 11 wW W In' , Power Tolerance (0,+3%) ---- 7 O(fl De Maximum System Voltage 1500V DC ___ -1 Y % Q U) F- Maximum Series Fuse Rating 25 A I') ^I - LL QSTC:bradiance 1000 W/m°module temperature 25°C AM--1.5 ��// Q 2N\w�e NOCT:Irradiance 800W/m'ambient temperature 20oC module temperature 45°C wind speed:lm/s Li. Power measurement tolerance:+/--3% _ �{ In U Temperature Characteristics ; °' J w / Z X _ p W o a o Pmax Temperature Coefficient -0.35/o/°C t•�` i = o J p U 0 Voc Temperature Coefficient -0.27%/°C1 11 a.oil nA-A Sao oil 69 U Q LO 51: 21: 101: 101: AO Isc Temperature Coefficient +0.05%/°C W AllOperating Temperature 40 +g5°C 'Refer to SEG installation Manual for details Nominal Operating Cell Temperature(NOCT) 45t2°C SIV SERIES � PRODUCT CERTIFICATION Q -- -- -- -------------------- Mechanical Specifications IEC61215:2016;IEC 61730:2016;UL1703;UL81730/CSAICEC p SEG Solar INC.(SEG)redefined the high-efficiency module series by IEC62804 PID I-V CUrve Z integrating 182mm silicon wafers with multi-busbar and half-cut cell 1EC61701 sae Mist External Dimensions 1722 x 1134 x 35 mm m Q technologies.SEG panel combined creative technology effectively IEC62716 Ammonia Resistance Weight 21.5 kg "N^ � Cn O and extremely improved the module efficiency and power output. IEC60068 Dust and sand ❑ W d IEC6121S Hailstone(25mm) Solar Cells PERC Mono(108 pcs) . � � , Fire Type(UL61730).1129(Typel-HV Type29-BG) ❑ r n --KEY FEATURES Front Glass 3.2/mm AR coating tempered glass/low iron . ❑ U J 1:2015 1509001:2015 ISO45001.2016 Q U1 IS01400 -- __ _ - ---- Frame Black anodized aluminium alloy j t W °. Less mismatch to get more power o + C€ ® Junction Box IP68/3 diodes N N Q O p Connector Type MC4 ❑ N Z Less power loss by minimizing the shading impact - INSURANCE Cable Type/Length 12 AWG PV wire(UUIEC)/1200 mm N ❑ ❑ LO Competitive low light performance P I C C Mechanical Load(Front) 5400 Pa/113 psfl w�N a N Fw } Q WARRANTY Mechanical Load(Rear) 3600 Pa l75 psfl N > m Beier to SEG installation Manual for derails 0 W o 3 times EL test to ensure best quality Z 98%11 8% Additional Value from Linear warranty Z .6% Packing Configuration w 3 ILI` Ideal choice for utility and commercial scale projects 93.05% Q a m by reduced BoS and improved ROI 90% 9o.3x e O s7.ss% Container 20'GP 40'HO Outstanding reliability proven by PVEL for a`89 Pieces per Pallet 31 31 = stringent environment condition: eox o 5 10 ,6 zo zs Pallets per Container 6 26 •Sand,acid,salt and hailstones years Pieces per Container 186 806 O Anti-Anti 25 Guarentee on product 25 Linear Oowx For details, lease consult SEG. w Z. e a e XrV material and workmanship output wananry P Spadanr SMWbfectbrliergawitlwotfuM noarxetiw SEG-D fN-2tl22VIACoopyrW92022SEG u l7 SEG SOLAR INC.(SEG) SEG SOLAR INC.(SEG) Q rWr 7 0 SEG Headquarter California office:6200 Stonerldge Mall Rd.,Ste 300 Pimsenton,CA 945M ( SEG Headquarter California office:6200 Stoneridge Mal Rd.,Ste 300 Pleasanton,CA 94588 U SEG San Antonio,Texas office:973 Isom Road San Antonio,TX 78216 SEG San Antonio,Texas office:973 Isom Road San Antonio,TX 78216 > Tel:925-468d198 Web:www.aegaolar.com q_ �: Tel:9254664198 Web:www.aegeolar.corn 7 NW L LL LO ❑ ❑ � ENPHASE W o 0 2 .. IQ8 Series Microinverters ❑ o 0 0 W " m EM T -- m z In .►��4' 4 to INPUT DATA�DC) IC18­60-2-US • N AN Z ❑ Commonly used module pairings2 IN235-350 J 235-440 260-460 295-500 320-540+ 295-500+ N ►��� U = Module compatibility 60-ceIV120 half-cell 60-ce1U120 half-cell,66-ce1U132 half-cell and 72-ce1U144 half-cellU = w 0 MPPT voltage range v 27-37 29-45 33-45 36-45 38-45 38-45 W c a i Operating range v 25-48 25-58 LL O m 0 Li L Min/max start voltage v 30/48 30/58 U J Q z o - Max input DC voltage v 50 60 p N F 0 Max DC current3[module Isc] A 15 I!1 LO Qt t Overvoltage class DC port II W 1 OC port backfeed current mA 0 ' PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit W = W Z O \ W w Peak output power VA 245 300 330 366 384 366 W In U Z ❑ 13 Max continuous output power VA 240 290 325 349 380 360 -3 01 F Nominal(L-L)voltage/range4 v 2401211-264 208/183-250 U m Q Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Q (Y .. J Nominal frequency Hz 60 F- N Q IQ8 and I Q 8+ M i c ro i n v e rte rs Extended frequency range Hz 50-68 _J o I- W W AC short circuit fault current over W J Our newest IQ8 Microinverters are the industry's first microgrid-forming,software defined Easy to install 3 cycles Anne 2 4.a r f� Q ❑ microinverters with split-phase power conversion capability to convert DC power to AC Lightweight and com act with lu n- lJJ J p L) power efficiently.The brain of the semiconductor-based microinverter is our proprietary p p g" Max units per 20 A(L-L)branch circuits 16 13 11 11 10 9yzaml � a lication s ecific inte rated circuit ASIC which enables the microinverter too rate in play connectorsPP P 9 ( ) Pe Total harmonic distortion <5% ❑ grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed •Power Line Communication(PLC) Zdigital logic and has superfast response times to changing loads and grid events,alleviating between components Overvoltage class AC port IIIconstraints on battery sizing for home energy systems. •Faster installation with simple two-wire AC port backfeed current mA 30 cabling Power factor setting 1.0Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging High productivity and reliability .+...ri.....,: ._.. •Produce power even when the grid is Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 _ I> Z Z down' CEC weighted efficiency % 97 97 97 97.5 97 97 ai Q. ❑ 1 LO �- -- --- •More than one million cumulative hours Night-time power consumption mw 60 ❑ W d of testing ❑ Part of the Enphase Energy System,IQ8 IQ8 Series Microinverters redefine MECHANICAL DATA ❑ ❑ U Series Microinverters integrate with the reliability standards with more than one •Class II doubte-insulated enclosure Ambient temperature range -40'C to+601C(40117 to+1401F) f- 0 In IQ Battery,IQ Gateway,and the Enphase million cumulative hours of power-on •Optimized for the latest high-powered M I J Z W App monitoring and analysis software. testing,enabling an industry-leading PV modules Relative humidity range 4%to 100%(condensing) N Q Q Q C� limited warranty of up to 25 years. DC Connector type MCa ❑ N Z r� MiCrogrid-forming Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") N Cq Q U J W •Complies with the latest advanced grid Weight 1.08 kg(2.38 Ibs) 11 l'- support— N } Q Cooling Natural convection-no fans m •Remote automatic updates for the r ❑ W latest grid requirements Approved for wet locations Yes Z Z w•Configurable 3 to support a wide range Pollution degree PD3 F- m Q Connect PV modules quickly and easily IQ8 Series Microinverters are UL listed of grid profiles cc) ❑ m to IQ8 Series Microinverters using the as PV Rapid Shutdown Equipment and Enclosure Class II double-insulated,corrosion resistant polymeric enclosureQ included Q-DCC-2 adapter cable with conform with various regulations,when •Meets CA Rule 21(UL 1741-SA)and IEEE plug-n-play MC4 connectors. installed according to manufacturer's 1547:2018(UL 1741-SB 5rd.) Environ.category I UV exposure rating NEMA Type 6/outdoor instructions. O Q Note: CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class 8,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 O W 1 ' LLII08 Microinverters cannot be mixed together with Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section previous generations of Enphase microinverters(I07 Series,IQ6 Series,etc)in the same system. 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to n L.L.`Only when installed with IQ System Controller 2,meets UL 2741. manufacturer's inStnlCGOn3. IQ8 and IQBPIus support split-phase,240v installations only. (1)The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See L W C the compatibility calculator at https:/Ilink.enphase.com/module-compatibility(3)Maximum continuous input 1 W O G ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters, DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required by the utility.(5) O and other names are trademarks of Enphase Energy,Inc.Data subject to change. IQ8SP-12A-0S-0067-03-EN-US-2022-12-27 Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-17 5 Z W �- ELECTRICAL NOTES 1 SOLAR PV EQUIPED WITH RAPID SHUTDOWN 2 MINIMUM K-AIC RATTING OF ALL BREAKERS TO BE 10K f 1 Enphase AC cable in Consumption CT's 3 VERIFY GROUNDING ELECTRODE&IF NONE INSTALL NEW VERSION HISTORY free air under module "A" nB„ „C., "D" 4 ALL CONDUCTORS ARE COPPER UNLESS NOTED OTHERWISE DB V# DATE I DESCRIPTION i AC&DC GROUNDING CONDUCTORS PER NEC ARTICLE RE 1 12i4/2023 Original 5 690.43(A)THRU(F)CONNECTED AS PER 690.45(A),690,46,& SIZED PER 250.122 LI ALL EXTERIOR MOUNTED COMBINERS,JUNCTION SNC6 BOXES,THROUGHS,DISCONNECTS,ETC.SHALL BE MIN. NEMA 3R RATED LATITUDE ELECTRICAL CONTRACTOR TO PROVIDE EXPANSION JOINTS 40.980690 •••••• t i I 7 AND ANCHORING OF ALL CONDUIT RUNS AS PER NEC REQUIREMENTS LONGITUDE 1 I•I _ 1•I I I TOTAL RATING OF ALL OVERCURRENT DEVICES,EXCLUDING -72.536820 I 1 1 I I N G 8 MAIN SUPPLY OVERCURRENT DEVICE,SHALL NOT EXCEED AMPACITY OF THE BUSBAR IJi SOLAR MAA,r",• UTILTY COMPANY: BREAKER t l I ` 9 THIS IR SYSTEM UTILISIDE ES HE ARNVERTE IM THERE ARE NO '•''•• � I DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER. PSEG LI J { I BRANCH-1 COMM HUB ( I — PROVIDE LABEL/PLACARD AT EXISTING UTILITY 4 ENPHASE ACCOUNT NUMBER "E" CONNECTION WITH"WARNING-CUSTOMER OWNED 10 ELECTRICAL GENERATION EQUIPMENT CONNECTED"WITH 9691148004 ENVOY >-__� MAIN BREAKER -- _' '-- APPROPRIATE HAZARD AND OUTPUT RATINGS OF PV ' I BRANCH-2 I 1 SYSTEM LOCATION OF OVERCURRENT PROTECTION AS PER NEC ARTICLE 706.31 _. 1 ' l X Overcunent protection for electric power production source conductors, • �-- 1 CUSTOMER'S INTERNET Q , (/i connected to the supply side of the service disconnecting means in I I I I I BRANCH-3 3 I CONNECTION O I i 11 accordance with 705.12(A),shall be located within 3m(10 ft)of the point IJ / 1 Z where the electric power production source conductors are connected to the HOMEOWNER: #1 Solar Module __�..� �`— — —.�.� �.,F.��_�.. service. #2 Micro Inverter I I ._ I Z r MISC NOTES 0 504.4.7 ROOFTOP CONDUITS AND PIPING.TO THE MAXIMUM Tracy Joseph X EXTENT PRACTICABLE,CONDUITS,INCLUDING CABLE TRAYS, Household ® I I—. •.— ( LL1 l� SA AND PIPING SHALL BE INSTALLED AT ROOFTOP LOCATIONS I WHERE THEY DO NOT OBSTRUCT ROOFTOP ACCESS LANDINGS, ADDRESS: CLEAR PATH OF REQUIRED CLEARANCES.IF IT IS ® I - I (- - ��► '1`�._ I IMPRACTICABLE TO AVOID THESE AREAS,CONDUITS AND PIPING 1330 Sigsbee Rd, SHALL BE DESIGNED AND INSTALLED TO FACILITATE ACCESS MattituCk AND MINIMIZE TRIPPING HAZARDS.STEPS OR RAMPS(OR , New York m PLATFORMS WITH STEPS,RAMPS OR LADDERS)SHALL BE 11952 PROVIDED THAT ARE CONSTRUCTED OF NONCOMBUSTIBLE I I I „� / \�_ I GROUNDING ELECTRODE COLD WATER SERVICE(E) MATERIAL,EQUIPPED WITH RAILINGS,AND DESIGNED TO ALLOW ® ( I -- G (1)i6 AWG GROUND ROD (1)i6 AWG COMPLIES WITH NEC ANY CONDUIT OR PIPING INSTALLATIONS THAT EXCEED 1 FOOT CONTRACTOR: I CU GEC DIA.8-LONG CU GEC 250.52 A 1 �' ( ) (305MM)IN HEIGHT ABOVE THE ROOF SURFACE,OR MORE THE 24 250." — COMPLIES WITH NEC 250." INCHES(610MM)IN WIDTH,TO BE READILY TRAVERSED.STEPS, Hytech Solar 250.52(A)5(8) RAMPS,PLATFORMS AND LADDERS SHALL NOT BE PLACED IN AREAS OR IN A MANNER THAT WOULD OBSTRUCT ANY DOOR OR ADDRESS: #4-Solar Load Center MEANS OF EGRESS.ALL CONDUITS AND PIPING INSTALLATIONS 89L AC DISCONNECT SHALL BE COLOR-CODED WITH CONTINUOUS,DURABLE AND 6 Washington Ave,Bay Shore, #3-Roof Top GENERATION PANEL #5-Existing Main #6-Existing Utility WEATHERPROOF REFLECTIVE OR LUMINESCENT MARKINGS AS NY 11706 FOLLOWS,AND FOR THE CONDUIT AND PIPING INSTALLED,SHALL Junction Box Service Panel Meter BE CONTINUOUSLY LABELED IN AN APPROVED MANNER. PHONE: SEE SYSTEM OUTPUT RATINGS CHART BELOW PROPOSED EQUIPMENT LOCATION 631-595-5500 FOR BREAKER SIZING UTILITY METER EXTERIOR OF HOME EMAIL: MAIN SERVICE PANEL BASEMENT iconnect@Hytechsolar.com SOLAR MODULES(N) ROOFTOP MASTER SOLAR LOAD CENTER(N) EXTERIOR OF HOME ELECTRICIAN: SOLAR SYSTEM OUTPUT RATINGS HOUSE MSP Timothy Houston EQUIPMENT TOTAL BRAND MODEL NOMINAL OUTPUT CURRENT 240V Voltage 1201240 ME LICENSE# SOLAR MODULES 37 SEG SEG-405-BMD-HV NOMINAL OPERATING VOLTAGE 1.21 Single ME-54187 PV MAX DC OUTPUT 14.985 kW Phase Phase ME PHONE# MICRO INVERTERS 37 Enphase IQ8PLUS-72-2-US PV MAX AC OUTPUT 11.1 kW Main 631-595-5500 INTERNET MAX AC OPERATING CURRENT 60 A Breaker 150 COMMUNICATIONS 1 Enphase Envoy-210,15 A OCP I I Or �f HUB LEGEND WIRE SCHEDULE SOLAR 89L AC TOTAL POWER OUTPUT=PTC RATING X# # EQUIPMENT # CONDUCTOR COLOR SIZE QTY CONDUIT >f PP��N K y9y0 DISCONNECT 1 SQUARED 125A BUS SERVICE RATED MODULES X Ill EFF 1 SOLAR MODULE THWN-2 B R #12 2 Z GENERATION LOAD CENTER,V A IN 1"Schedule 80 PVC n PANEL PTC RATING DC 376.5 W 2 MICRO INVERTER ECG THWN-2 G #8 1 7 1 LOAD CENTER MAIN BREAKER W/TIE DOWN OCP 60A MAX INVERTER EFFICIENCY 98% 3 JUNCTION BOX THWN-2 B R #10 2 P TOTAL POWER OUTPUT DC(W) 13,596.17 4 SOLAR LOAD CENTER B ECG THWN-2 G #6 1 IN 1"Schedule 80 PVC o90 Og 6S i O� 5 j MAIN SERVICE PANEL THWN-2 B R #12 2 �FSSI' C IN V Schedule 80 PVC :' ��- - Branch Information Branch-1 Branch-2 Branch-3 6 UTILITY METER ECG THWN-2 G #12 1 SCALE PROJECT TOTAL MODULES 13 12 12 THWN-2 B R W #6 3 NTS I 2023-HTOI82678089 BRANCH VOLTAGE 240V 240V 240V D IN 1"Schedule 80 PVC ECG THYVN•2 G #8 1 PHOTO-VOLTAIC INVERTER AMPERAGE 1.21 A 1.21 A 1.21 A E ECG G #6 2 Solid Bare ELECTRICAL 3-LINE DIAGRAM BRANCH AMPS X 1.25 19.6625 A 18.15 A 18.15 A OCP 521T,2P,20 A 521T,2P,20 A 521T,2P,20 A E-100.00 PAGE 1 OF 1