Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
50826-Z
Fa TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50826 Date: 6/18/2024 Permission is hereby granted to: FWiozzi PJ Family Trt . ______ ... ._ _.... . 39 Osborne Rd Garden Ci NY 11530 To: Construct alterations to finish a basement to include an HVAC system to a single-family dwelling as applied for. At premises located at: 120 Caiola Ct, Greenport SCTM # 473889 Sec/Block/Lot# 33.-3-19.15 Pursuant to application dated 4/26/2024 and approved by the Building Inspector. .../ µ To expire on m12/18/2025._ Fees:. SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $1,277.50 CO-ALTERATION TO DWELLING $100.00 Total: $1,377.50 ...._...... .-...... Building Inspector � ' '" TOWN OF SOUTHOLD-BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownMLgov Date Received APPLICATION FOR BUILDING PERMIT Y� For Office Use Only PERMIT NO, 5 a� Building Inspector: - 1 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization,form(Page 2),shall be completed. Date: ;23 A-V V-k L 24- OWNERS)OF PROPERTY: Name: SCTM#1000-33 03-' t9.I S PfC1Tc1�. ��4+-LoZ2,1 Project Address: I;t0 CAIOLA f-Ot. 97 4 p-,egu PbeT, u%j Phone#: 5-1 la . &sg, t g S3 JlEma,ll: P lei ca,102zl a r-14un2z •eorv\ Mailing Address: 39 'oS&oQ 1%AS "OV0, 41rat?Aw 0'" , My LLS60 CONTACT PERSON: Name: TNt�t-H�.IYv� Mailing Address: z1 ce,,1 m,9— sTiLlEm- ", woArl'OfAar-T, Wy. I1W9 Phone#: &51 • (o97 . 777,0 all: -nAmr- N e- mc•Gom DESIGN PROFESSIONAL INFORMATION: Name: Jti,f-F I-V-WNLVAF IY'%lC,9 Mailing Address: ;LI of U i�.(Z ST4F-If:-T, Mown-)A.')VT, lay. 1110 Phone#: (61 , (o97. 77?•d Email: -n-\t*,AVeC1J a rAF- •Cbm CONTRACTOR INFORMATION: Name: JpAvrT 5VWLA5Wt0.,K Mailing Address: t) 41auI-CSflf->s 1pti wS 0- , e-ejul-eRfbo- , t-1y 11721 Phone#: S-)(o . B S4-. 2r)$1 Email: $$C 3(o I G AQIL cYL*\ DESCRIPT#ON OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteratlon'❑Repair ❑Demolition Estimated Cost of Project: " Other Vi"151'1 W 4)Cfz,*,M6AAT t IO,oc1� Will the lot be re-graded? ❑Yes o Will excess fill be removed from premises? ❑Yes XNo i q r x h 1 ,ms 1 BTJ 1 G rw EFIT. a s o . PROPERTY INFORMATION Existing use of property: syU4L, ppm . Ck4ILItAA Intended use of property: S►UGtA,VfAM CKA*w)uG p this property? and restrictions with respect to Zone or use district in which remises is situated: Are there an ? ❑Yes$No IF YES, PROVIDE A COPY'. Check box After Reading: The owner/contractor/design profesdonal Is responsible for all drainage and storm water Issues as provided by apter 236 of the Town Code.APPLICATION IS HEREBY MADE to the Bullding Departrrlent for the Issuance of a Bullding Permit pursuant to the Bullding Zone Ordinance of the Town of Southold,Suffolk,County,New York end other applicable Laws,Ordinances or Regulations,for tfie wnstrudlon of buildings, addtdons,aharatlons or for removal or demolition as here(n described.lfia applicant agrees tb comply with aR appltwble laws,ordinances,bulldine code, housing code and regulations and to admit suthori:ad Inspectors on promises and In bultding(s)for necessary Inspactlons.False statements made herein are- punishable as a Cie ss A misdemeanor pursuant to section 210AS of the New York State Penal Law. Application Submitted By(print me): ja„ �11.�(..1p2Z1 []Authorized Agent NOwner Signature of Applicant: Date: 2.3 AnfZ-'Z—A- STATE OF NEW YORK) SS: COUNTY OF_-�L Ir p �*� ►_ being duly,sworn, deposes and says that(.*he is the applicant (Name of individual signing contract)above named, (J)he Is the off'. (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed In the manner set forth In the application file therewith. Sworn before me this 93 day of 20 ry Public IIEIrf THA lA lR PROPERTY OWNER AUTHO!IIZATION ft"'c.Sta of 140V Y ok NO 011IM14""13 (Where the applicant is not the owner) ,olffied in SefiblkCot I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 From: Rhett Brunswick bbc361 @aol.com Subject: Re:Figliozzi East Date: April 23,2024 at 9:56 AM To: Jeff thalarch@me.com t i C (-D O 0 cn' IPrf e En O _ cD m -xo c CD CD : v9 in CD m r C z n � m 0 0 o 3' D V N ;' v' � O � n 'o N -, to Z t0 0 o W n N ;U n N) o D C m O rn -� rn Zz m Z N v cn j Z M (j (D O i z ►Ti cn �T %I��/���dl,To l/i ✓%%r �a Nl Workers' CERTIFICATE OF yTA�Ti: Compensation BoardNYS WORKERS' COMPENSATION INSURANCE COVERAGE 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured BBC Associates Inc 516-884-2781 9 Bankside Drive North 10.NYS Unemployment Insurance Employer Registration Number of PO Box 611 Insured Centerport, NY 11721 Work Location of Insured(Only required if coverage is speaficaNylimiled to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e., a Whap-Up Policy) Number 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) United Farm Family Insurance Co Town of Southold Town Hall Annex 3b.Policy Number of Entity Listed in Box"1 a° 54375 Main Road 3102W9695 PO Sox 1179 Southold,NY 11971 3c.Policy effective period 08/20/2023 to 08/20/2024 3d.The Proprietor,Partners or Executive Officers are included.(Only check box if all partnerstofficers included) ® all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers"Compensation Law.(To use this form, New York(NY)must be listed under, on the INFORMATION PAGE of the workers compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These,notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the Insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or after the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained In the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note..:Upon cancellation of the workers"compensation policy indicated on this form,If the business continues to be named on a parmit,license or contract Issued by a certificate holder,the business must provide that certificate holderwi'th a new Certificate of Workers'Compensation Coverage or other authorized proof that the business Is complying with the mandatory coverage requirements of the New York State Workers' Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: (Print name of authorized representative or licensed agent of insurance carrier) Approved by: (Signature) (OaW) Title: Telephone Number of authorized representative or licensed agent of insurance carrier. Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C405.2 (947) www.wcb.ny.gov � DATE(MM/DONYYY) 4�o CERTIFICATE OF LIABILITY INSURANCE 04/09/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer ri hts to the certificate holder in lieu of such endorsements. 10DUCER ON Katie Jackson Brian Micena (631)8 1-2200 F NAME No: 100 South Jersey Ave ' katie.ackson arnerican-national.corn Unit 33 INSURE M AFFORDING COVERAGE NAIC East Setauket, NY 11733 INSURER A: Farm Famil Casual Insurance Conn an 13803 ISURED INSURERS. United Farm Family Insurance Ctdm an; 29963 BBC Associates Inc INSUReRIa; 3 Bankside Drive North INSURER 0. IN,SUFkER E ;,enterport NY 11721 I SURER F :OVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. 9iR Ad&MW POLtC FF POLICY EXP LIMITS rR TYPE OF INSURANCE POLICY NUMBER D M k X COMMERCIAL GENERAL LIABILITY 3101 L6894 09/07/23 09/07/24 EACH OCCURRENCE $ 1,000,000 G, 0"tTrM $ 100,000 CLAIMS-MADE "OCCUR )"� euttro hNEO EXP rAn aeon $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 G'ENt AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE S 2,000,000 X ❑ PRO- ❑ PRODUCTS-COMP/OP AGG $ 2,000,000 POLICY JECT LOC $ OTHER: cc AUTOMOBILE LIABILITY 3152C5891 05/12/23 05/12125 E � d OnlSl L IT $ 1,000,000 ANY AUTO BODILY INJURY(Per person) $ OWNED X SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPE'RIYOAMAGE $ X AUTOS ONLY X AUTOS ONLY X UMBRELLA LIAB X OCCUR 3152E2305 08/29/23 (? i291 4 EACH OCCURRENCE $ 5,000,000 EXCESS LIAR CLAIMS-MADE AGGREGATE $ 5,000,000 $WORKERS DED RETENTION$ COMPENSATION 3102W9695 08/20/23 08120124 X srnT TE ERH AND EMPLOYERS'LIABILITY ANYPROPRIETORIPARTNER/EXECUTIVE YIN N/A E.L.EACH ACCIDENT $ 100,000 OFFICER/MEMBEREXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 100,000 If yes,describe under E.L.DISEASE-POLICY LIMIT $ 500,000 DESCRIPTION OF OPERATIONS below ESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,maybe attached if more space Is required) ;arpentry :ERTIFICATE MOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town Hall Annex THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 54375 Main Road ACCORDANCE WITH THE POLICY PROVISIONS. PO BOX 1179 AUTHORIZEDREPRESENTATIVE Southold, NY 11971 JL ©1988-2015 ACORD CORPORATION. All rights reservet ,CORD 25(2016/03) The ACORD name and logo are realstered marks of ACORD ZN EW workers' CERTIFICATE OF INSURANCE COVERAGE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrie 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured BBC&ASSOCIATES INC 631-821-2200 PO BOX 611 CENTERPORT,NY 11721 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(only required if coverage is specifically limited to 113434206 certain locations in New York State,i.e.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold Town Hall Annex 3b.Policy Number of Entity Listed in Box"1 a" 54375 Main Road DBL204711 PO Box 1179 3c.Policy effective period Southold, NY 11971 09/18/2023 to 09/17/2025 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 4/9/2024 By ( U hf (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton,,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 4113,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) p Tele hone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DS-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) lI�IID "' 1w2i0�i1iiii(i1i2iwi21)ii�l� Generated by REScheck-Web Software Lompliance Certificate Project Figliozzi Residence Energy Code: 2018 IECC Location: Greenport, New York Construction Type: Single-family Project Type: Alteration Climate Zone: 4 (5572 HDD) Permit Date: Permit Number: All Electric false Is Renewable false Has Charger false Has Battery: false Has Heat Pump: false Construction Site: Owner/Agent: Designer/Contractor: 120 Caiola Court Peter Figliozzi Jeff Thalheimer Greenport, NY 11944 120 Caiola Court Thalheimer Architecture Greenport, NY 11944 21 Center Street Northport, NY 11768 631. 754. 8621 thalarch@me.com ..m: ,. "' „; „ .. r m m ,,. m � .. .. � , m .; ,. m uw • mw ., SW,"m...011 ado ade to adE!^Offs u" N no Ilou geii m;onsiiderEwd in ullne UA or p,peii.foi unr-ai nce comllAarice pa tll®u iin lilErSchec1c, Each s allIn..on..grade assembly In the spebified r:Iliiiraaate zorue a��uaus in'a?et the irr0rflr11Lf 11 a;;on^neM gy code iiurssfladon II`K-v allu e and dep tllri requ.uikervnerit, Envelopge__A55emblies • ® s Basement Wall: Wood Frame Wall height: 9.0' 2,472 15.0 0.0 0.051 0.059 122 141 Depth below grade: 8.0' Insulation depth: 9.0' Door: Glass Door(over 50%glazing) 21 0.300 0.320 6 7 SHGC: 0.35 Window: Wood Frame 62 0.300 0.320 19 20 SHGC: 0.35 Project Title: Figliozzi Residence Report date: 04/23/24 Data filename: Page 1 of 9 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has Peen designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requireffnents listed in the REScheck Inspection Checklist. �Z A 23 npvt 2-4- Name-Title Signature Date Project Notes: Compliance is for finished basement Project Title: Figliozzi Residence Report date: 04/23/24 Data filename: Page 2 of 9 REScheck Software Version REScheck-Web Inspection Checklibt Energy Code: 2018 IECC Requirements: 94.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions [[PR1]1 Re .ID 03.1, Construction drawings and ❑Complies Requirement will be met. 03.2 documentation demonstrate ❑Does Not energy code compliance for the Location on plans/spec: building envelope.Thermal ❑Not Observable See General Notes envelope represented on ❑Not Applicable construction documents. _ 1 Construction 103. documentation demonstrate . ..._... .. pDompNot... m... ..µ _m.... �. ,.drawingsRequirement will bee met. es 403.7 energy code compliance for Location on plans/spec: [PR311 lighting and mechanical systems. ❑Not Observable See General Notes Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. _ 302.1, sized Heating per co Man equipment ual S based is Btu/hr ...u.Heatin.._ ._ .DD...._. .i .�.._ �....�..; ement will be .et. .._._... ........ . Heating: Heating. ❑Complies Requirement will be met. p oes Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Location a plans/spec: Manual J or other methods Btu/hr Btu/hr See General l Notes approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 wHighITITlmpact(Tier 1) 2 Ti 3 Low Impact(Tier 3) Medium Impact(Tier 2) Project Title: Figliozzi Residence Report date: 04/23/24 Data filename: Page 3 of 9 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- � ❑Complies t bee forvalu e .__....... m base ___.....�-- � ee the Envelope Assemblies e.Where interior R- R- ❑Does Not es. i, insulation is used,verification may need to occur during []Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. mWw ... .. _ ......._...._. _..._... . .. .. ,- w_..._........... ......._ �..w ......_. . ... 303.2 Conditioned basement wall ❑Complies Requirement will be met. [F05]1 insulation installed per ❑Does Not manufacturer's instructions, ❑Not Observable Location on plans/spec: See General Notes ❑Not Applicable 402.2,9 Conditioned basement wall ft ❑C ._..... ft P ..�.. _�.-��_____..�.��_��. - � omplies See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 1 A protective covering is installed ❑Complies Exception: Requirement is [FO11]2 to protect exposed exterior ❑Does Not not applicable. insulation and extends a minimum of 6 in. below grade. []Not Observable []Not Applicable 403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is [FO12]2 controls installed. ❑Does Not not applicable. , ❑Not Observable Location on plans/spec: ❑Not Applicable See General Notes Additional Comments/Assumptions: t( i" 3 rr Tier 2) Low Im — .._ Project Title: Figliozzi Residence Report date: 04/23/24 Data filename: Page 4 of 9 . ...... Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID _. .._..._. ...�., 402.1.1, GlazingU-facto_.._....._. __ ._._._.. ...._._. r(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3,3, ❑Not Observable 402.5 402.5 ❑Not Applicable m0. 303.1.3 U-factors of fenestration products ❑Complies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable Location on plans/spec: taken from the default table. ❑Not Applicable See General Notes 402.4.11 Air barrier and thermal barrier ❑Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. Location on plans/spec: ❑Not Observable See General Notes []Not Applicable ...................... .... ....._ .. _ __. ..._......... _....__.... _ _ ..-..-.._...... 402.4.3 Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5W IC-rated recessed lighting fixtures _ _. .... ... ................... ...... _._..... __..._ es ❑Complies Requirement will be met. [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate :52.0 cfm Not Observable Location on plans/spec: leakage at 75 Pa. See General Notes ❑Not Applicable 403.3.1 .. _ .._.. ......... _....._ ... .. _. 3. Supply and return ducts in attics ❑Complies Requirement will be met. [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= Location on plans/spec: R-6 where < 3 inches. Supply and ❑Not Observable See General Notes return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.2 Ducts, air handlers and filter ❑Complies Requirement will be met. [FR13]1 boxes are sealed with ❑Does Not � joints seams compliant with ❑Not Observable Location on plans/spec: � International Mechanical Code or See General Notes International Residential Code, as ❑Not Applicable applicable. ......... ._ _.............-- 403.3.5 Building ca vities are not used as ❑Complies Requirement will be met. [FR15]3 ducts or plenums, []Does Not ❑Not Observable Location on plans/specs See General Notes ❑Not Applicable . m,�. .._. ._... __ .... ,, .. _.....__ _..�.- ._... . ... ........ ..._.µ 403.4 HVAC piping conveying fluids R-Pm w R ❑Complies Requirement will be met [FR17]2 above 105 °F or chilled fluids ❑Does Not below 55 °F are insulated to >_ ❑Not Observable R- Location on plans/spec: 3, See General Notes ❑Not Applicable PP 403.4.1 Protection of insulation on HVAC ❑Complies Requirement will be met. [FR24]1 piping. ❑Does Not ❑Not Observable Location on plans/spec: NotesSee General ❑Not Applicable 403.5.3 Hot water pies are insulated to R- R- ❑Complies Requirement nt will ....... p - � be met. I[FR18]2 >_R-3. ❑Does Not ❑Not Observable Location on plans/spec: See General Notes ❑Not Applicable -.... ...... ........... _. .�..._ 1403.6 Automatic or gravity dampers are ❑Complies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable Location on plans/spec: ❑Not Applicable See Gen eral Notes 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact (Tier 3) Project Title: Figliozzi Residence Report date: 04/23/24 Data filename: Page 5 of 9 Additional Comments/Assumptions: '[2eqi Wl—mpact(Tier 2) [---TLow I —r;pact(Tier 3) .......... ................ Project Title: Figliozzi Residence Report date: 04/23/24 Data filename: Page 6 of 9 Section Plans Verified Field Verified �, Value IT Value pYYuunm' mptions 303e1�°_. _ __.... p Comments/Assumptions & R1 All installed insulation is labeled ❑Com lies Requirement will be # Insulation Inspection Com Complies? met. [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable _.._..... _ .. _ ........ . .._ __.....m, _........ _. ... 402.1.1, Wall insulation R-value. If this is a R- R ❑Complies see the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable ...- 303.2 Wall insulation is installed per ❑Compliesmmmmmmmmm mITIT Requirement will be met. [IN4]1 manufacturer's instructions. ❑Does Not []Not Observable Location on plans/spec: ❑Not Applicable See General Notes Additional Comments/Assumptions: 1 p—High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact (Tier 3) Project Title: Figliozzi Residence Report date: 04/23/24 Data filename: Page 7 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID _.__. -.......... .. 402.2.4 Attic access hatch and door R- R ❑Complies [FI3]1 insulation ?R-value of the []Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_-.- ACH 50 = ❑Com plies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable ..... _. .................. .�..... _. _ 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Requirement will be met. [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total ❑Not Observable Location on plans/spec: leakage measured with a See General Notes pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. ............... ._.-..gtest _ _... ._..�............. � ,.. [03.14 Duct tights ssacross t result system< 4 ft2 cfm/100 ft2 cfm/100 OComplies Requirement will be met. Does Not <=3 cfm/100 ft2 without air Location on plans/spec: handler @ 25 Pa. For rough-in ❑Not Observable See General Notes tests, verification may need to ❑Not Applicable occur daring Framing Inspection, ..�__.......... _ � 403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met. [FI24]1 by manufacturer at <=2%of ❑Does Not design air flow. Location on plans/spec: ❑Not Observable See General Notes ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable Location on plans/spec: initially set by manufacturer to See General Notes code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies Requirement will be met. [FI10]2 on heat pumps. ❑Does Not [:]Not Observable Location on plans/spec:. See General Notes ❑Not Applicable ........ _.., w. ._ .. ... 403.5.1 Circulating service hot water ❑Complies Requirement will be met. [FI11]2 systems have automatic or []Does Not accessible manual controls. ❑Not Observable Location on plans/spec: See General Notes ❑Not Applicable 403.;.6 ..,1....... All mechanical ven.._._.�______,�. ...._.....,M.....,-.............._� ___...... .._.._..._.....� mm ..._.-.. __ _. tilation system ❑Complies Requirement will be met. [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy Location on plans/spec: and air flow limits per Table ❑Not Observable See General Notes R403.6.1. ❑Not Applicable .................................... _...,M_,. ._ ................ .. ............._.......mmm 403.2 Hot water boilers supplying heat ❑Complies Exception. Requirement is [FI26]2 through one-or two-pipe heating ❑Does Not not applicable. systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 1 Hi h Im act(Tier 1) 2 ediumul mmmmmmm 1 g p mpact(Tier 2) 3 Low Impact(Tier 3) Project Title: Figliozzi Residence Report date: 04/23/24 Data filename: Page 8 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions e4��......µ 403. __ _ _._ �..� �_............. & R 5.1.1 Heated water circulation systems ❑Complies Requirement will be met. [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated ❑Not Observable Location on plans/spec: return pipe or a cold water supply See General Notes pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.... ........... ----- - _.. _ ........ �....... ............ 1.2 Electric heat trace systems ❑Complies Exception: Requirement is [FI29]2 comply with IEEE 515.1 or UL ❑Does Not not applicable. 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Demand,_ ._..� __ .... ..... .... _ ... ............. ... ... _.. recirculation water ❑Complies Requirement will be met. l[F130]2 systems have controls that ❑Does Not manage operation of the pump Location on plans/spec: and limit the temperature of the ❑Not Observable See General Notes water entering the cold water ❑Not Applicable piping to <= 104°F. 1403.5.4 Drain water heat recovery units ❑Complies Exception: Requirement is [F131]2 tested in accordance with CSA ❑Does Not not applicable. B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for [:]Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 90% or more of permanent ❑Complies Requirement will be met. [FI6]' fixtures have high efficacy lamps. ❑Does Not Location on plans/spec: ❑Not Observable See General Notes ❑Not Applicable W. .,.- lighting s ..�._ .. .u..._ .. - __......... __�.... ....... 404.1.1 Fuel gas g htin g systems have ❑Complies Exception: Requirement is [FI23]3 no continuous pilot light. ❑Does Not not applicable. r ❑Not Observable ❑Not Applicable 40112........... Compliance certificate posted. ❑Do Not OComplies Requirement�_ _....�_. ._3 p _ ....... W. will be met. []Not Observable ❑Not Applicable .._._. _.. .....-..... .....__,. _ _ .................... __.. _ - �.. ... ........... .......mm �_.... 303.3 Manufacturer manuals for ❑Complies Requirement will be met. [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: s_.. _ .... 3 Lo {{ 1 High Impact (Tier 1) 2 ., Medium Impact(Tier 2) w Impact(Tier 3) Project Title: Figliozzi Residence Report date: 04/23/24 Data filename: Page 9 of 9 C40" 2018 �IECC Energy �(j Efficiency Certificate CEMMEMEEMEMESEMEM Above-Grade Wall 0.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 0.00 Ductwork (unconditioned spaces): Window 0.30 0.35 Door 0.30 0.35 Heating System: Cooling System: Water Heater: Name: Date: Comments " SOS' OF LOT 15 SUFFOLK COUNTY DE ARTMEN1�F Fi�� ���VtCES 0 ' ROC O,�T $TATES p Rev .OF OOHS 6 90"�1 Fc SHUATE AT CLW',E"E'.�PORT kr--NCE AND � Ftt��'RFC► TO Off" S0 H0' A_0 41� SUFFOLK COUNTYs NEW YORK Date _ 0 ` ►6t at +►s jocwjo a h ,ra aOn LOT 12 ley yB r' The sewa90 d►sFon►and water sUPPlY Ud FILED: 0611112001 MAP No. 10637 Wes ttTs t j ►nspectad and/or oer►fted ttite►s R ent Ogg, �, be t Fa and/ �6 t"�i"f"R�L IAWAOa OF 0Om . S.C.T.M. No. 1000-33-03-19.15 14 " �, x . LOT AREA = 28,271 S.F. ELEVATIONS PER NAV88 DATUM. gCraig ,. Knryeepper,^ �E., Chief ge► c I V POOL DW X SCDHS REF. No. R10-19-0010 44 eDIA.z 2000 GALLON SEPTIC TANK O FILTER B'DMW I 10, DIA. X 13, DEEP LEACHING POOL x4+g9 x GLtiWTLANTEES OR OERTIFTGATTONS ARE NOT TRANSFERABLE UNDERGROUND UTNURES LOT 15 WrAjENTS ND'T SHOWN AND UIIUTY POLE LOCATIONS ARE'NDT CTFATdANTEENA. ,. THE OFFSET DIMENSION"W N HMEON FROM THE,STRUCK' TO THE"PROPERTY UNES n C , ARE FOR SPC*nC PURPOSE AND USE, TTFEREFORE ARE NOT INTENDED TO COW THE &VCMN OF FEI CES RETAWWO WADS, PC= PAIIOSr PLANT ARM �• t X ADORTION TO SUMMIC'S.AND OTHER CONSTRUCT404 THE EXISTENCE, OF AXW OF WAYS, WETLANDS ANT/OR EASEMENTS OF RECORD. IF ANY. NOT SHOWN ARE NOT GUARANTEED UA WAtORPE'D ALTERATIONOR ADO WN TO IMS SURVEY IS A WO'L)TON OF 0� � 1 w� �. c NOT BEARING BEARING 7209. THE LAND URVEVORS SIGNATURE AND RID INK OREM TBOSSED SEAL SHALL X. U. NOT LO CONSIDERED A TRUE IST VALID COPY. 6."•, ALL LOCATIONS OF AND DISTANCES TO WELLS AND CESSPOOLS ARE BY IACATiONS b�+" 4C .� { FROM HOMEOWNERS FIELD 4BSERVATPDNS'AND DR IWIORMATION OBTANNED FROM WZt sr �p $. �^ " OTHERS. SINCE MOST ARE NOT VRq E THESE"N,OCATNONS No OIwwwaNS CANNOT 7ZAT� LOT 14 �• ROOF DRAIN 0. O! BE CERTIFIED_ 4 1 BUILDING DATA. Xr�3 FIRST FLOOR = 2,385.9 S.F. �+" ~! `' , , e� �,,.. SECOND FLOOR = 1,299.6 S.F. topo GARAGE = 508 S. X " ay, X C 6, A FRAMN DECK ` ��.� 1 ' PD. ALEC. S.T. TELE. dIEIE .0 x Q � VAULT .0'0 10 r. TELE. A r GARAGE B' D�Z4. % B' DEEP -_' SAND J �` �! A , Ok' ✓'" GF=25.1 "' ROOF DRAIN \ ' g6 P A.C. WV. .` F p`MR*w W'#@ a•ww, mow"» � �y UNITS w+uF „,ate FD. SECCAFI CO LAND SURVEYINPC U t3 in 1foN N 77°1061" 1P 161.36' 1rox. 500 Mon tauk High way a� Moriches, New York 11955 LAND NOW OR FORMERLY OF Phone: (631) 878-0120 Phone (631) 728-5330 TAN OF SOVTROLO (E cE WiV) pseccafico@optonline.net Pat C. Sec cafico. PLS Pat T. Seccofico. PLS 0 1 12 81=2 2 WArZ RNMED NYS Lic. No. 051040 NYS Lic. No. 049287 1113012021 FINAL SURVEY copyright — 2021 Seccaflco Land Surveying PC PROJECT No. 62250 SCALE: 1" = 30' DATE: 0310812021 3� - 3- � �. �s a�� Sasa� A6scaso�ls " THA_LIIEIMER A R C HI T E C T U R E TWENTY ONE CENTER STREET NORTHPORT NEW YORK `'i Y'"''• �' 11768 631 754 8621 , •T:t R`='a ' - y" ''f "" --+r,-.r .,ram .- _ .._.-. .._ ' 41, +i�: .ak," ,,.r ,rw .c�rAr ,m �' ����r,;r�, B'�,,.. .'�-•. ..n.. � � .-., _ r :.7 ^`a-,,� - ',�� �•i�'. 9C`a ai �"� � a } .+t��'�- g 3t'-_ '� %, ",sa - '''" 4ya...Y1�� ai•.www ,. .,_.. _ T 5 - ,. ,a- -„ ,,r °" ^r,* ,5i A- '°n.� o.' R"., 1 n�pia A .. -.. .,,. '^,! '. � � sY� '_ ,. .. - t ._.-,--•-ter' �' � � `: � „w" "%".> -_•'_ � i -. - I - f � �..r f� _.. .i I} 4-. _. '.•m.,,,nC - � � ; ,�.a�,-' qqw� 7 ,C J`�l �r 77� {( - '"tad. r .ys - ;~7tR^k Q.� '1 • t .- ..g,�,,;,, ..,. �i .. i ..- .•.. ., .., ' 3• 1r , [ w .. .,-.. .:..n?'xwr' s' ,y =,,.. -'Satvi'✓ - - - 4 _ 'r i6,°;'' ,:R®-1 :.icy duo t .�. „i _ .. ,,,r _ _ - _ x.., .,».. :�:., >+.t �.�,er`•� j � .�.6...., i i ��"-. 1 4 ` _ - ��1��•' �."p 1 .} 1 - I 5 ,- ., - ... ., �'3=.�4.m » .r ,8; : '^" `<'+l�n�>'M! an' - - -#P 1 p I} w f" 'k 4, 't 1 : �'S ' A 1, •� t•. .nR - �t �"'*:..4n 41; a q E ''. '4r "7"` 1� t �1 t �e( 3 Y' po-� .`&P.r •+Rq C. 7 r+, ; n1^ i,�•#,o� "• ''r -�-.-.,._,., 1. -.., ti,. ., � bt `�-YR.Y,' t' ,:� „Y x ,..fit#ftt _ _, .. - �'y`nr�f t - ^ k, y, _ z " �„:` j,1 i _ f< 'tt• e - .ak- S .. .} M. C� a 14— t - - _^. _ _... -- ..,,,,' _F ,i • - ...._ -_ - _ .k:. 4,: �G .. '" � - - _ .., dP" e .4�, 'gin-4,f r� m�.:.'a ,� .. ,: _ f��a �.. i t,r .-• _ ,,,'�_ ,, pr, .a a» 4 _ �-'t _ ,.,� �, y 4; _ ,.Aw...- .r-. ,_ •. _ - �f4-�.c•....._,�ir, _.. �svL �• _ _ _ x .. }i �'y �wr H �.-w-i -�r � '"tl"�. f�`r fk - - i_ ,. - -- .., , - `e..,-,.-•....„- ...a..,... .- ,.,.,wae.•.* -^^r`� _ ....-- .fir."` ,a' ",g` j a .r `,1 ,A�� k ". � " .. ,r.. -.. r^. .,�- �k;w;_,,.,. yw,.1W-Aw•A.,,ved..<.W..-MwY1l+.rs'9',cv - - � __..., ... .ffi,.,.- , ,1 �• .+ - , i' ... . � - } ., * ; �' .... - .+I mrs'�r•"'...+..s:•...+^'"`"a."'..r i^•..".,` - _ - - _ - •..r r, ,. —y „`- '., - w^..,r +...,.a -J v ro ' r - � x,e -. , . .. , , ylr+w!�-S'm`62.A➢3W%' p..+•*MA•-�d ..,.�......x......m_ ..,.r... _....o..-»...,,.,,.ate ':� ... ._ ,...u.n. .....r,. .a r..x ii. . . _ .<, ....r.._..J...r aw,a..e,..�'..N[.D.1�"➢...Yv'A4s.,Y.s.-- .,_,....- x. _ 1. _ , ♦ ^ . " +{r. ' e • y j„�n _ �P"�h9�� � ru^n l 0 W 0 0 -E G R R 120 C a COUR NPOR 11944 0 U Project Directory : Index of Drawings : Vicinity Map : THALHEI:'MER ARCHITECTURE Sheet No. 120 Caiola Ct. 0 Architecture lof 6 Cover Sheet 21 Center Street U Northport, New York 11768 2 of 6 Site Plan / Climate Data / Plumbing Riser Diagram / General Not 0 3 of 6 Basement Plan / Details 631.754.8621 Tel. 4 of 6 Electrical + Reflected Ceiling Plan thalarch@ine.com �u'' ° S T 1 R L I N (,,f 5 of 6 Bathroom Elevations �� oa p� ��� . a AR_ SECCAFI(�O LAND SURVEYING PC 6 of 6 Existing First + Second Floor Plans o�No p o �\k° Surveyor !"E F T $00,4 p R° x �` VAr-"'* *-# I (M I 500 Montauk Highway 11 P02068� o Moriches, New York, 11955 3 n 48 o 25 OF NE`N� 114 o� r poIN NpMESffA� r Euf1fT ` .878. 0120PA631 RK ;Ptlpo g m ��L � if-I T FINISHED pseccafico@optonline.net N - Q NeENWE .415 o ��, �,��� p STIRI r�1G BASEMENT 3 z3 a rvr z = ;-!ate PIAtN ° CEM. ' °0 o tP o o ° _ Ma R t a� 90 F 3 T Fd OUTHOLD 0 WAS 41ft�y EX 0 w ° ,�.r•�Q 0E �`_ r ��7�� QsK/N�toN �-. M SCALE: N.T.S. REV. TOWN lV O S to EDAR Z v GHSqu) E•�-" ay Town Hall Annex ~ SM�''�',,6 ou CF M. chi a_ 1© , ° �,n� ��f v i _ DRAWN BY: J.E.T. REV. 54375 Route 25 wa w ST f�Stf7? DATE: 18 APR 24 REV. Southold, New York, 11971 �^.� f JoMHsoH �, 25 S7'CGNEs SitU�r CT ROAD s' i 631.765.1892 '�°A "OpTN s� L N np s\\ Scch '�, u °^` PROJECT NO. , fi U LL TRAILF_R C� t 1 r I L L 2' N 0 9 T N PARK ._ 3 SIT CA, S?ca�t`+� At yo r r. MAOISo t0 S. r8f w 0 D ,� 4 BBC ASSOCIATES V w sr En �T �p�`���U r.,�D" ���°'/ DRAWING �St v f CE��T ? ., a �cr► v, d r- �-(�"j 1`ai�� �V 1 OF ID General Contractor v r►t N. 5. a 9 Bankside Drive N. o .S ST Centerport, New York, 11721 �iN Rp .. V.K "D�S .�N FRONT.' Ost -4 GREENP01 THESE PLANS ARE AN INSTRUMEHT OF SERVICE AND ARE H T Q STT THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS Q JOCK �.� O T2 ""� ILL BE PROSECUTED. Rhett Brunswick �oR wtF©f N�G ,NS aSt CONTRACTOR SHALL VERIFY ALL CONDITIONS AND EASUREMEHTS IN THE FIELD AND BE RESPONSIBLE FOR 516. 884. 27 IT AND QUANTITY Of WORK. NO ALLOWANCES SHALL E MADE IN BEHALF OF THE CONTRACTOR FOR ANY RROR OR NEGLECT ON HIS PART. . C 2024 Thalheimer Architecture S 1 L e P 1 a n SCALE : 1" = 30' CHECKL 15T 0 d0er a THALIIEIMER .. RESCHECK INSPECTION CHECKLIST NOTATIONS : 2018 IECC CODE SECTIONS : SEC. 403. 3. 4 �; 4, cam` x A R C H I T E C T U R E DUCT TIGHTNESS TEST RESULT OF LESS THAN OR EQUAL TO 4 cfm/ 100 ft2 AGR055 THE SYSTEM OR SEC. 103. 1, 103. 2 THE55 THAN OR EQUAL TO 3 cfm / 100 ft2 WITHOUT AIR HANDLER 6 25 Pa. FOR ROUGH IN TESTS, POOL Of x TWENTY ONE CONSTRUCTION DRAWINGS AND DOCUMENTATION DEMONSTRATE ENERGY CODE COMPLIANCE FOR THE VERIFICATION MAY NEED TO OCCUR DURING FRAMING INSPECTION. \ ages O B p,B,BP CENTER STREET BUILDING ENVELOPE. THERMAL ENVELOPE REPRESENTED ON CONSTRUCTION DOCUMENTS. F7LTCsR b I SEC. 403. 3. 2. 1 .09 /o LOT 15 NORTHPORT SEC. 103. 1, 103. 2, 403. 1 AIR HANDLER LEAKAGE DESIGNATED BY MANUFACTURER AT LESS OR 2 OF DESIGN AIR FLOW NEW PORK CONSTRUCTION DRAWINGS AND DOCUMENTATION DEMONSTRATE ENERGY CODE COMPLIANCE POP , LIGHTING AND MECHANICAL 5Y5TEM5. SYSTEMS SERVING MULTIPLE DWELLING UNITS MUST SEC. 403. 1. 1 / � A°', � 11768 DEMONSTRATE COMPLIANCE WITH THE IECC COMMERCIAL PROVISIONS. PROGRAMMABLE THERMOSTATS INSTALLED FOR CONTROL OF PRIMARY HEATING AND COOLING 631 754 8621 j SYSTEMS AND INITIALLY SET BY MANUFACTURER TO CODE 5PECIFCATION 0 SEC. 302. 1 403. 40' E N a' DIA. ar a' ngEP HEATING AND COOLING EQUIPMENT IS 51ZED AS PER ACCA MANUAL '5' BASED ON LOADS SEC, 403. 1. 2 tv Boor mux g '°$e R CALCULATED PER ACCA MANUAL V OR OTHER METHODS APPROVED BY THE CODE OFFICIAL NEAT PUMP THERMOSTAT INSTALLED ON NEAT PUMPS. U PROPOSED FINISHED BASEMENT b SEC. 402. 1. 1 SEC, 403, 5. 1 2,055 S.F. CONDITIONED BASEMENT WALL INSULATION R - VALUE. WHERE INTERIOR INSULATION IS USED, CIRCULATING SERVICE HOT WATER SYSTEMS SHALL HAVE AUTOMATIC OR ACCESSIBLE MANUAL �` �• o VERIFICATION MAY NEED TO OCCUR DURING INSULATION INSPECTION. CONTROLS PROPOSED BASEMENT SEC. 302, 2 SEC. 403. 6. I EGRESS WELL CONDITIONED BASEMENT WALL INSULATION INSTALLED PER MANUFACTURERS INSTRUCTIONS. ALL MECHANICAL VENTILATION SYSTEM FANS NOT PART OF TESTED AND LISTED HVAC EQUIPMENT 01. Lp SHALL MEET EFFICACY AND AIR FLOW LIMITS. 4i0 ' �� o ° �• "AMR DR" SEC. 402. 2. 9133.920 / �, a �� ;� (s.s' sacs) , . d' 133.920 % �� 1 �r �.°.. d- CONDIITONED 5A5EMENNT WALL INSULATION DEPTH OF BURIAL OR DISTANCE FROM TOP OF WALL . a6 /7/ , . �Q° S.T. B s.s `S s SEC. 403. 5. 1. 1 r-+ SEC. 402. 1. 1, 402. 3. 4 HEATED WATER CIRCULATION SYSTEMS HAVING A CIRCULATION PUMP. THE SYSTEM RETURN PIPE IS A BVAETLT� / ¢4 sx '•p0 w GARAG9 ' 0 b DOOR U-FACTOR. SEE ATTACHED ENVELOPE ASSEMBLIES FOR VALUES DEDICATED RETURN PIPE OR COLD WATER SUPPLY PIPE. GRAVITY AND THERM05YPHON Asa c.vT1 / °� R a• nrA. x e DEEP �A. / BOX / GF=RS.I 14.�' ❑ k ROQr' nTtA1N x CIRCULATION SYSTEMS ARE NOT PRESENT. CONTROLS FOR CIRCULATING HOT WATER SYSTEM PUMPS SEC. 402. 1 402. 3. 1 402. 3. 3 402. 5 START THE PUMP WITH SIGNAL FOR NOT WATER DEMAND WITHIN THE OCCUPANCY. CONTROLS -AGns .ss o �' �`` R GLAZING U -FACTOR. SEE ATTACHED ENVELOPE ASSEMBLIES FOR VALUES AUTOMATICALLY TURN OFF THE PUMP WHEN WATER IS IN CIRCULATION LOOP AT SET-POINT 0 oo, ti O TEMPERATURE AND NO DEMAND FOR NOT WATER EXISTS. �- ` �• xoi SEC. 303. 1. 3 n MON N ?'prl0'51 r w 161.38 U-FACTORS OF FENESTRATION PRODUCTS ARE DETERMINED IN ACCORDANCE WITH THE NFRC TEST N Lem Now OR FOM&MY of PROCEDURE OR TAKEN FROM THE DEFAULT ID TABLE SEC. 403. 5. 2 Tow Or so (RSCgARGri w HASi N) DEMAND RECIRCULATION WATER SYSTEMS HAVE CONTROLS THAT MANAGE OPERATION OF THE PUMP SEC. 402. 4. 1. 1 AND LIMIT THE TEMPERATURE OF THE WATER ENTERING THE COLD WATER PIPING TO 104. D, F. •. AIR BARRIER AND THERMAL BARRIER TO BE INSTALLED AS PER MANUFACURER5 INSTRUCTIONS. E-+ SEC. 404. 1 MPS CLIMATIC 4 GEOC-iRAP-IIC DESIGN CRITIEZIA 0 SEC. 402. 4. 3 90°ro OR MORE OF PERMANENT FIXTURES HAVE NIGH EFFICACY LAMPS. 0 Q FENESTRATION THAT 15 NOT SITE BUILT IS LISTED AND LABELED AS MEETING AAMA / WDMA / CSA / ALL WORK SHALL COMPLY WITH THE REQUIMMENTS OF THE 2020 RESIDEMIAL BUILDNG CODE OF NEW Yow STATE. 4.4 101/1.62 / A440 OR HAS INFILTRATION RATES PER NFRC 400 THAT DO NOT EXCEED CODE LIMITS. I. ALL REQUIRED INSPECTIONS BY THE GOVERNING MUNINCIPALITY BUILDING OFFICAL AS PER CODE CAOM wIND DESIGN SEISMIC �ECTTODAMAGEFROM WNTER ICE-eARRIER FLOOD AIR MEAN SECTIONS R104. 2. 1 THROUGH R104. 2. 5 SHALL BE SCHEDULED BY GENERAL CONTRACTOR AT SIM DESWN DESIGN Y HAZARDS NG ANC W LOAD >�D TOPOGOGRA�PgNIC BFfCIALI WND 9 CATEGORY ILE4TI RMG F�� TEWITE TEMPER411� RE00ED INDEX TEMP. SEC. 402. 4. 5 APPROPRIATE TIMES DURING CONSTRUCTION. COORDINATE WITH BUILDING OFFICIAL. zOw MODER IC-RATED RECESSED LIGHTING FIXTURES SEALED AT HOUSING / INTERIOR FINISH AND LABELED TO 20RSP.. 'J20PN M NO NO NO C SEVERE ATE T VY BDM YES NO sw R5Dog. INDICATE LE55THAN OR EQUALTO 2. 0 CFM LEAKAGE AT 15 PA. 2. AIR LEAKAGE TESTING MUST BE CONDUCTED BY AN APPROVED THIRD PARTY TESTING ENTITY IN ACCORDANCE WITH CODE SECTION R402. 4. 1. 2. A DETAILED WRITTEN REPORT OF THE TESTING CODE C01-IFL IANT STATEMENT SEC 403. 2. 1 RESULTS MUST BE SUBMITTED TO THE BUILDING DEPARTMENT PRIOR TO FILING FOR CERTIFICATE OF [--i SUPPLY AND RETURN DUCTS IN ATTICS INSULATED GREATER OR = R-8 WHERE DUCT 15 GREATER OR OCCUPANCY. TO THE BEST OF THE UNDERSIGNEDS MOMEDGE,W- MATION AND PROFESSIONAL BELIEF,THE ATTACHED =3 INCHES IN DIAMETER AND GREATER OR = R-6 WHERE LESS THAN 3". SUPPLY AND RETURN DUCTS IN OFNsti�llcTION TATE AND T MEET 0 EXCEED THE MMIMUM REQUIERMEMS OF THE OF N R Yowl TA CODE OF NEW PORK STATE AND THE 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW PORK STATE. OTHER PORTIONS OF THE BUILDING INSULATED GREATER OR = R-6 FOR DIAMETER GREATER OR = 3" 3. PRIOR TO FILING FOR A CERTIFICATE OF OCCUPANCY, GENERAL CONTRACTOR SHALL PROVIDE A O AND R-42 FOR LESS THAN 3" IN DIAMETER 'PERMANENT CERTIFICATE' TO BE POSTED ON A WALL IN THE MECHANICAL ROOM. THE CERTIFICATE U SHALL PROVIDE ALL APPLICABLE VALUES FOR BUILDING INSULATION R-VALUES, DUCT INSULATION SEC. 403. 3. 2 R-VALUES, FENESTRATION U-FACTORS AND SHGC, RESULTS OF AIR LEAKAGE TESTING PERFORMED ON DUCTS, AIR HANDLER6 AND FILTER BOXES ARE SEALED WITH JOINTS / SEAMS COMPLIANT WITH 2O20 THE BUILDING AND DUCTWORK, EQUIPMENT TYPES AND EFFICIENCY OF HEATING / COOLING / SERVICE RESIDENTIAL CODES OF NEW YORK STATE. WATER HEATING 0 H SEC. 403. 3. 3. 5 BUILDING CAVITIES ARE NOT TO BE USED AS DUCTS OR PLENUMS U (SENEfRAL NOTE5 O SEC. 403. 4 N HVAC PIPING CONVEYING FLUIDS ABOVE 105D. F. OR CHILLED FLUIDS BELOW 55D. F. SHALL BE INSULATED TO GREATER THAN R-3 SEC 403. 4. 1 1. THE PROPOSED WORK ON TH15 BUILDING SHALL COMPLY WITH APPENDIX V OF THE 2020 RESIDENTIAL PROTECT INSULATION OF HVAC PIPING BUILDING CODE OF NEW YORK STATE. SCOPE OF WORK UNDER APPENDIX V SHALL BE CLASSIFIED AS AN `,�� ED oy,� 'AppITION' AND ALTERATION - LEVEL 2. WORK FOR 'ADDITION' SHALL COMPLY WITH SECTION AJ801, AND WORK � �afill r SEC. 403. 5. 3 FOR ALTERATION - LEVEL 2 SHALL COMPLY WITH SECTION AJ601. HOT WATER PIPES TO BE INSULATED TO GREATER THAN OR EQUAL TO R-3 * r 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2020 RESIDENTIAL CODES OF NEW YORK STATE, r SEC. 403. 6 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE. �Ty 020*`6 you AUTOMATIC OR GRAVITY DAMPERS ARE TO BER INSTALLED ON ALL OUTDOOR AIR INTAKES AND OF NE`N EXHAUSTS 3. ALL WORK SHALL COMPLY WITH CODE SECTION R310 FOR EMERGENCY ESCAPE AND RESCUE OPENINGS. SEE LOCATIONS ON FLOOR PLANS FOR 'EGRESS' OPENINGS. 411 VTR AIL 411 VTR JIL _ ROOF FINISHED 5EC. 303. 1 ALL INSTALLED INSULATION 15 LABELED OR THE INSTALLED R- VALUES PROVIDED. 4. ALL WORK SHALL COMPLY WITH CODE SECTION R314 + R315 FOR SMOKE ALARM AND CARBON MONOXIDE I i to ExISTING STACK VENT BASEMENT ALARMS. SEE FLOOR PLANS FOR LOCATION OF UNITS. SEC. 303. 2 I I ABOVE To ROOF WALL INSULATION SHALL BE INSTALLED AS PER MANUFACTURERS INSTRUCTIONS 5. ALL WORK SHALL COMPLY WITH CODE SECTION R401 FOR FOOTINGS AND FOUNDATIONS. SEE PLANS AND xiSTINCx sol!_ LINE SCALE-AS NOTEDREV. DETAILS FOR 51ZE OF FOUNDATION WALLS + FOOTINGS, STEEL REINFORCEMENT, DRAINAGE, DAMP PROOFING, ETC; #BAR I BATH 1 BATH #2 SEC. 403. 3. 2 2 NEW FIXTURES I 2 NEW FIXTURES 3 NEW FIXTURES I DRAWN BY: J.E.T. REV. TIE INTO EX16TING S.CAD. DUCTS SHALL BE PRE:65URE TESTED TO DETERMINE AIR LEAKAGE WITH EITHER: ROUGH IN TEST: 6. ALL WORK SHALL COMPLY WITH CODE SECTION M1201 FOR MECHANICAL CODE, CODE SECTION G2401 FOR FUEL I I APPROVED SANITARY SYSTEM PATE: 18 APR 24 REV. TOTAL LEAKAGE MEASURED WITH A PRE55URE DIFFERENTIAL OF 0.1 INCH w.g. ACROSS THE SYSTEM GAS CODE, CODE SECTION P2501 FOR PLUMBING CODE, CODE SECTION E3401 FOR ELECTRICAL CODE. r - -I- - -T - - - T - �- - -1 INCLUDING THE MANUFACTURERS AIR HANDLER ENCLOSURE IF INSTALLED AT TIME OF TEST. PO5TCON5TRUCTION TEST: TOTAL LEAKAGE MEASURED WITH A PRESSURE DIFFERENTIAL OF 0.1 INCH �i. ALL CONCRETE SHALL BE 3500 PSI± 28 DAY STRENGTH DISH I. 2�, I I.1V2 I-I 1_1121 I_IY2il 1-1I w. .g WASI�ER I SN IWER j ACROSS THE ENTIRE SYSTEM INCLUDING THE MANUFACTURERS AIR HANDLER ENCLOSURE. PROJECT NO. � L t 8. ALL NEW FOOTINGS SHALL BEAR ON VIRGIN WITH AN ASSUMED SOIL LOAD BEARING CAPACITY OF 2 TONS / S.F. 02 1 1 I BASEMENT '3. ALL STRUCTURAL FRAMING SHALL BE DOUGLAS FIR2 AND BETTER - �' 2° - 2� -.. 211 - - - EJECTOR D RA1�1/I N G 4" 501L SO �� � 4" IL. PUMP OF 4" SOIL THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND I I l Q MEASUREMENTS IN THE FIELD AND BE RESPONSIBLE FOR f L UM15 1 N� FZ 15 r 1 ` � I FIT AND QUANTITY OF WORT(. NO ALLOWANCES SHALL NOT TO SCALE BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HIS PART. . C 2024 Thalheimer Architecture 10"POURED CONS.FOUNDATION WALL ON 24"x 12"CONC.FTG. L= (3)ro BARS CONT.s FtG. Cln L CEMENT STUCOO FINISH AT INTERIOR OF ..J t WELL.PROVIDE 2"STONE CAP AT WALL.4° 6 x 6 AC GL POST. ADJUST RO OF EXISTING DOOR ABOVE PATIO. TO REMAIN AS REa I 36"HIGH BUILT IN p I CABINET WITH CLOSED PROVIDE 24"DEEP CLEAN GRAVEL AT DOOR STORAGE BY BASE OF EGRESS WELL TO WITHIN " TIIA HEIMER low 1 1 EXISTING STEEL COLUMN AND I OWNER - WINDOW SILL Est. u DROPPED STEEL BEAM TO , � A R C H IT E C T U R E �n I "MAIN BLACK POWDER COATED ALUM.LADDER le I u a n MOUNTED TO WALL AS REQ. II '>� 13 -1 1111(0111, 113 4 4 _i� 1 PROVIDE POWDER COATED ALUM HINGED r TWENTY ONE GRATE COVER AT WELL REMOVE PORTION OF FOUNDATION II' WALL FOR NEW FIXED WINDOW.FROM I 1� CENTER STREET PRIOR TO NEW POUR DRILL HOLES N 3 !`� 2 X 4 FURRII�x ON FLAT SILL PLATE TO NEW WINDOW SILL I EXIST,FOUND.FOR 05 REBARS s 12"VD.C. WITH P/,°RIGID INSUL.BTWN NORTHFORT PATCH TO MATCH AS REQ i BAYS_ . - PROVIDE TEMP.EXTERIOR FINISH - 0 NEW YORK OVER VAPOR BARRIER I EXISTING STEEL COLUMN MODIFY EXISTING WINDOW REMOVE EXIST.WINDOIU. AREAWELL AS REQ.DUE TO - I OUTLINE OF EXIST.STEEL ------ to _ CONSTRUCTION 1176E COLUMN TO BE (2'-8"x -a^ I SAWCUT EXISTING FOUND.WALL EXISTING EXTERIOR - REMOVED w w4 EXISTING WINDOW TO REMAIN FOR NEW EGRESS WINDOW. :n \ 631 754 6621 _ BASEMENT STAIR TO REMAIN, r /SEQr=ATI0N I a I BLOCK IN RA.WIDTH A5 REQ \t- IDA M 4ADD ON TO END OF WALL AS =d - - - -_ �? 1 WEST REQ.To CONCEAL cmuMN x --— \ FINISNEQ SJT � ° , �� ua� , I ALIGN WALLWITH COL.NEW 311z" ID.STL.PIPE COL ON - Q30"x 30"x 113"CONC.FIG.(3) �, I a II cv 2'-4"x 6'-86► � 5 BARS EAC-W WAY.SAWICUT I n u.= a�+ ' + '_ II 11 I 1 nA 8 SLAB AND PATCH AS REQ 2 -� -Z� ® 4 8 4 4 4 -4 BAR CABINETRY, t1 z REMOVE EXISTING COLUMN ATH 0Z COUNTERTOP AND - I ( � <t- VENT EXHAUSTAPPLIANCES BY OWNER REMOVE EXISTING COLUMN -I IleN r I -I--- ----------- - -�, " 30W'x 30iID.1817�PNIPE COL ONFAN TO PAD OUT WALL TO ENCLOSE: l a x I ,�----- " 3 EXTERIOR c� I I EXIST.(2)14 MICROLAM FLUSH BEAM TO REMAIN= I `\ EXISTING ELECTRICL AND AN '� I I L J VERIFY 1N FIELD L J I (- 5 BARS EACH WAY.SAWICE)T 3 `I - \ \ PANELS.PROVIDE CONCEALED 3 SLAB AND PATCH A5 REQ d � HINGED FLUSH ACCESS PANELS � EXISTING STAIR AND - - `\ k\ WITH EDGE PULLS.VERIFY SIZE - IN FIELD —RAILING TO REMAIN I 2 I I I c s @ vAC LNIT 3T \ AS CUT BACK WALL TO a4 3 , TIG� µ pODT pNyl FRAME L ta AS .w. ICE P-=F EXISTING STEEL ctl i I v v �' v MECN. _ COLUMN vJ+', TCONCEBALINGS$OILiLINEry i4 SIB \ �� n SHELVES / �rnil 41f'-4"x 6 81��®II All EXIST UNT \ �J J fLJ `t w� O EXISTING DEHUMIDIFIEE AND � \ Q AH I CONDENSATE PUMP REMOVE AND RELOCATE - - c� PIPE 6l-2"HT. EXISTING DEDICATED VENT EXHAUST ___ `\ FAN TO T DEHUMIDIFIER AND EXTERIOR �O PROVIDE ADEQUATE WAT CONDENSATE PUMP. COLRD. r-4"x -a" SERVICE ACCESS AND �`` NEW LOCATION WITH OWNER VENTILATION TO EXISTING TYPICAL PERIMETER WALL EQUIPMENT. V.I.F. VAPOR BARRIER ON FOUND.WALL ff EXISTING EGRESS 2 x 4 WOOD STUDS 16 O.C. METAL SILL PLATE SLEEVE WINDOW AND WELL TO _ ^ REMAIN R-1513ATT INSULATION NEW WALL CONSTRUCTION %H GYP.BD.FINISH 4" : 2 x 4 STUDS s III I' O.G. b" : 2 x b STUDS 6 Ib" D.G. N SEE ELEGTRICAL AND REFLECTED CEILING PLAN FOR ALL NOTES SC,AI.E : 1/4"=1'-O" 3 PROPOSED CEILING HEIGHTS AND SOFFITS. COORDINATE ALL IN SOUND MITIGATIOt1 WALL B FIELD PRIOR To STARTING ELECTRICAL ROUGH IN L EXISATING GYPSUM BOARD FINISHES AT CEILING SHALL BE REMOVED AS REQUIRED To COMPLETE PROPOSED WORK OR AS REEQUIRED FOR ACCEPTABLE LEVEL CEILING FINISH. VERIFY IN FIELD. EXISTING FOUNDATION WALL 2. AT ENTIRE BASEMENT FLOOR WITH EXCEPTION OF MECHANICAL ROOM,GENERALCONTRCATOR SHALL PREP EXISTING SLAB AS REQUIRED FOR CERAMIC TILE PLANK FLOOR,MUD SET. FOR BIDDING PURPOSES PROVIDE MATERIAL ALLOWANCE OF t S.00/SR INCLUDING WASTE,GROUT,TAX AND DELIVERY. COLOR OF GROUT To BE SELECTED BY OWNER USE SAME ALLOWANCE FOR THIN SET TILE WALLS AS SHOWN IN BATHROOMS. 3. ALL NEW INTERIOR DOORS AND HARDWARE SHALL MATCH EXISTING AT FIRST FLOOR IN TYPE,STYLE AND FINISH, CARBON MONOXIDE ALARMS SHALL BE PROVIDE PRIVACY LOCKS AT GUEST AND BATHROOM ENTRY DOORS PROVIDED IN ACCORDANCE OITH 2O20 PROVIDE DUMMY TRIM AND MAGNETIC CATCHES AT DOUBLE SWINGING CLOSET DOORS. RCN.Y.S. PROVIDE FLOOR OR WALL MOUNTED DOOR STOPS AS REQUIRED. NO UPPER CABINETS _ - ►-1 g SMOKE ALARMS SHALL BE PROVIDED IN F..J 4. ALL NEW BASE TRIM,DOOR AND WINDOW C:A.SING SHALL MATCH EXISTING AT FIRST FLOOR IN SPEGISES,PROFILE. VERIFY IN FIELD ACCORDANCE WITH 2020 RCN.Y.S. M � 5. EXTEND EXISTING HOT WATER SERVICE SYSTEM To ADDITIOANL FIXTURES AS SHOWN. VERIFY ADEQUACY OF EXISTING SYSTEM IN FIELD. COORDINA5TE WITH OWNER WHETHER RETURN CIRCULATING SYSTEM IN BATH n. ICE / \ / \ DLI \ b. COORDINATE WITH OWNER TYPE OF H.VAC.SYSTEM TO BE INSTALLED IN ANY. ALL NEW RVAC.WOW SHALL COMPLY WITH STATE CODE AND 2020 KY.S.ED.C.C. <11 1. ALL NEW WINDOWS SHALL BE JELD-MIEN TO MATCH EXISTING SERIES WINDOWS.ALL HARDWARE AND FINISHES SHALL MATCH EXISTING. \ p4 ALL NEW WINDOW SIZES SHALL BE COORDINATED WITH OWNER PRIOR TO ORDERING, F-1 ELEV. A u 3 Q N EXTERIOR WALL EXIST.FLOOR JOISTS CONSTRUCTION CLIP CONNECTION TO V.I.F. ALUM.POWDER COAT BEAM I® ,t I I OVEiRAME .48 REQUIRED iERED qR HINGED GRATE MICROLAM READER SEE PLAN �h --- - �G Rp 2"x2" TUBE FRAME WI 2'x2'xI/4 GRID INFILL 5ATH \ n PROVIDE: HOLD OPENGYM k~~ �1 DEVICE I WALL �ir' . .b Ei n n r.... (p _ Ci 5 X 10 X 1/2 WELDED ON . :::;:;i`i::;i`•,.:ii;[:::,..:;:i.: ;::i:`.:::i;::i::.:ii::,:i:.;:ii.:i>:.;:;:::`:;is..,::.::.:;:;.::i:..;6i:::Eii.ir..:>:.5.::%:;:•,.';;J,..',:i':;:.';::'i...:i;;:::::;i':.i.::.::i:.;i;i::i:;:3i:::i.:.i:`::i::... .. : ..::.. ...:. ::... '� 2 THK BLUESTONE CAP BEARING PLATE ( I DIA st3 ¢ 6 CRAWLSPACE WELL I BOLTS PER COLUMN V. .. TILED WALL L OF EW.(O _d LEAVE INSIDE EDGE OF ; 12" FOUND.EXPOSED TO 3� DNA.STEEL PIPE COL. T.O.SUBFLOOR Q. p p D ACCEPT COVER GRATE NON - ADJUSTABLE .=1c�, -_._ L(NE OF RECESS II _ , FINISHED ALUM,F 1'1E 6 OP ING Q BASEMENT 1 " STONE s A L d CEMENT PARSE F NISH , B WALLS PATCH FLOOR TO MATCH SHELVING TO BE FULL EXIST. ::. ::....• :.. :: ;.::.:.::.:.:::: ::;::: .::.:•.:..:..::. :..... :.:............ ............. ,..:.... . : ..::.:.....: x I 1 ::..........:...:.::: :..:....;.::<.::.:.:..;.:.>,..•:.:;...:,, tY CALE:AS NOTEI?R 1 4 a, d EGRESS WINDOW.SEE - {<, : < : :`' ... W/ TILE COURSING. S EV. 3 JUN 2 SAW GUT EXIST.GONG.SLAB — cn s `N VERIFY (N FIELD PLANT FOR SIZE I STUDY Q a ;:. a a EXIST.SLAB w DRAWN BY: J.E.T. REV. a : CONC.FOUNDATION AT FRAMING 4' WALL : 2" x 4" WOOD STUDS s ib" O.C. TILE RECESS TO DATE: 18 APR 24 REV. ' WELL :: T.O.FIN.FLOOR _ „ WALL b WALL : STAGGERED 2 x 4 WOOD STUDS EL. #100'-0" CDURSINCz. VERIFY IN x:. 12" DEEP CLEAN d 1b" O.G.ON 2" x b" PLATE FIELD e . 8 X 10 X 3/4 WELDED ON BLUESTONE GRAVEL " v , _ BEARING PLATE - - --- - INSULATION 2i2 SOUND ATTENUATION BAIT INSULATION BY ROXUL TO FILL STONE SLAB _ a CONC.FOOTING STUD CAVITY "''. INTERIOR PERIMETER PROJECT NO_ L L POWDER COATED ALUM ° (SEE PLAN FOR SIZES) OF RECESS. TUBULAR LADDER FINISH EATH !LAUNDRY PROVIDE No GOLD BOND XP GYPSUM F. N -.�- 5 REBARS v 12" O.C.EACH WAY ANCHORED TO WALL e A WITH 5 A (PURPLE) 11 WO BOARD AT flITGN BOTTOM d z WONDER B RD RD PORG Rq RP OR SHELVES OF RECESS T.O.SLAB HALLS TO RECIEVE STONE OR TILE. DRAWING a : d UNDISTURBED SUBGRADE rN E BEDROOM !PUBLIC SPACES PROVIDE 5ia° GOLD BOND DRAINAGxE Df 2 TON MIN.BEARING CAPACITY GYPSUM BOARD AS BASE LAYER AND N," GOLD BOND ° . Q ° li :I III 4d eOUNDBREAK AS FINISH LAYER INSTALLED AS PER t IANUFACTURER5 SPECIFICATIONS. THESE PLANS ARE AN INSTRUMENT Of SERVICE AND ARE 1 ! I ELL DETAIL ( 'ham f� RESISTANT I TILED I THE PROPERTY Of THE ARCHITECT. INFRINGEMENTS 4 I I r2--� 1 1 &� DETAIL COLUMN 3 DETAIL J" T SOUND ice. � I I ice. �"` `/ DETAIL L WILL BE PROSECUTED. EGRESS 3 v CONTRACTOR SHALL VERIFY ALL CONDITIONS AND SCALE : 3" ' 1'-0" 3 SCALE ' 3" ' 1'-0" MEASUREMENTS IN THE FIELD AND BE RESPONSIBLE FOR FIT AND QUANTITY Of WORK. NO ALLOWANCES SHALL 3 SCALE : �/4' = -m 3 SCALE : �/4° = 1'-m" BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HIS PART. . C 2024 Thalheimer Architecture rlrl 'RIM �c V�l irA R C H I T E C T U R E qp TWENTY ONE CENTER STREET NORTHPORT r NEW YORK 1 60J 1 ' / \\ 11768 631 754 8621 i i G� \ 1 E • i G Cx G G G G G Cs G G 1\ GLCs GLGqprra" Cl GYM NEW LIGHTS AT STAIRWELL TO BE \ \\ i �\ // \�\ \ u \ / 4 -(p} t9'-0"CLG -( WIRED TO MOTION DETECTOR AND EXISTING SWITCH IN BASEMENTCLG IX GLCs GLG �`i�'' \ \ �• RELOCATE CEILING MOUNTED ROUTER AS REGL ,�?� ----- Y Y F EXISTING ELECTRICAL AND AN PANELS. \�' 17 �a ----___---' \\\ SHELVE5 I US ��\ 3 r3 UBF3 U �1 w � I ��. //� \\\ \\ ^ PROVIDE CONCEALED HINGED FLUSH � D D � .�A ACCESS PANELS WITH EDGE PULLS.VERIFY Cl Lu \\ 00 \ - � ------- SIRE IN FIELD ,_-- , _____ � \ \\ ____ L � A _ _- — � ,� \ \I \ D — p )] \ \ t9'-G" -_Ca�10" �Q� •'\:rc t6'-12J t�'-II" 1'-11" 6'-10 \ I \\ _9 —TO EXIST.LIGHTS \\ CLG CLCx�.'� ����GLCa GLCs CLCx GL�Z�' CLCx CLCx \\\ '� \ \ ---- \\ / - - Diu.— ^- - - - -1- -� - - - ABOYE \3/3 - ------ \ / IGE REI= _ I I LUM � I� D MECH. \\ GreFI — — — ; ; ac try SHELVES ( I UNIT I ^\ � U9E3 L — — — — _J DE+lA11D eEJE�T) eTA \ \ IT AT t8'-S"AFF. U .. A � ( \ � `;T SOFFIT AT tl'-11"APP. PROVIDE POWER TO NEW EXISTING GYPSUM BOARD EJECTOR PLIMP AS CEILWs IN MECH.ROOM REQUIRED GA96a ADO rT w n ELECTRICAL AND REFLECTED CEILING ELAN N T� � NOT)vS w : L LOCATION OF ALL INDICATED CEILM DROPS,SOFFITS TO BE VERIFIED IN FIELD PRIOR TO START OF ELECTRICAL ROLKaHING. 2, PROVIDE ACCESS PANELS AT ALL MECHANICAL VALVES,ELECTRICAL BOXES,ETC.AS REQUIRED. U 3. ALL FINISHED CEILINGS TO BE No"GYPSUM BOARD.PROVIDE M.R.BOARD IN BATHROOMS. U Q Y T ICAL NOTEES � DUPLEX RECEPTACLE 1 ALL WORK SHALL CONFORM TO N.E.C., AND THE 2020 E.C.C.C.N.Y.S. ALL WIRING ERED ARo QUADPLEX RECEPTACLE SHALL BE COPPER �5 p,RD T DUPLEX G F I RECEPTACLE PROTECTED 2. GENERAL CONTRACTOR SHALL PROVIDE AIR-TIGHT SEAL HOUSINGS AT m a AT PANEL RECESSEDfXTURES AS REQUIRED BY CODE. N .� LUMI LED TAMPER RESISTANT DUPLEX OUTLET LIGHTING I TU UL 9TF o6a8 yo�� L P 3. ALL FIXTURES AND LAMPS TO BE SUPPLIED INSTALLED BY GENERAL NE`N WITH NIGHTLIGHT BY LEGRAND 0 NTL 8,35 TR CONTRACTOR EXCEPT AS NOTED. MANUFACTURER cAT. No. LAMP REMARKS DEDICATED RECEPTACLE AT PANEL 4. EXACT LOCATION OF ALL FIXTURES, SWITCHES AND DEVICES SHALL BE A FIXTURE AND LAMP TO BE SUPPLIED BY OWNER AND INSTALLED 5Y GENERAL CONTRACTOR RECEPTACLE: WITH USB CHARGER DETERMINED IN FIELD BY OWNER PRIOR TO ROUGH IN. B LEVITON KEYLESS 25 W 2100 K LED SURFACE MOUNTED WHITE PORCELAIN SOCKET FINISHED U�>� LEVITON MODEL # T 5632 C I.UAC UJS - 248 30 lU 2100 K LED 48" WALL MOUNTED CLOSET LIGHT BASEMENT HEIGHT TO BE VERIFIED IN FIELD 5. ALL OUTLETS, SWITCHES AND DIMMER5 SHALL MATCH EXISTING AT FIRST D ELCO - KOTO SERIES E3LK(o5ICA HOUSING / ELK O'921 MODULE / ELK 3ro1aW TRIM 10 W 2100K LED PEX 3" ROUND DOWNLIGHT FIXED FLOOR OF HOME. ALL DIMMERS SHALL BE 'UNIVERSAL' NEW SWITCH / SINGLE POLE E ELGO - KOTO SERIES E3LKt 51CA HOUSING / ELK 0921 MODULE / ELK 3(olaUJ TRIM 10 UJ 2100 K LED PEX 3" ROUND DOUJNLIGHT WET LOCATION -- — -- -- --------- „ SCALE: 1/4"-1'-0" REV. 13 JUN 24 �3 NEW SWITCH / 3-WAY . ALL LED LAMPS SHALL BE 2100K / WARM WHITE UNLESS NOTED OTHERWISE F NUTONE XN 110 ULTRA GREEN ------------- EXHAUST PAN - 6 D IA. DUCT IN SCHEDULE. G LED( V5 - SPEC - 1.5 - 30K - LENGTH - CHI - SQ - F 1.5 W 2700K LED LED STRIP LIGHT WITH SLIM STANDARD CHANNEL / FROSTED LENS DRAWN BY: J.E.T. REV. NEW JAMB SWITCH $ NEW SWITCH / TIMER (5-10-15-30) 1, GENERAL CONTRACTOR SHALL SIZE ALL DIMMABLE MAGNETIC POWER DATE: 18 APR 24 REV. T SUPPLY UNITS AS REQUIRED FOR LOADING. D NEW DIMMER 1600 WATT g ALL PROPOSED GFI OUTLETS/ CIRCUITS IN KITCHEN AND BATHS SHALL BE PROJECT NO. - - NEW RECESSED LIGHTING FIXTURE PROTECTED AT PANEL. L L Q NEW SURFACE. MOUNTED LIGHT FIXTURE DRAWING V CONTINUOUS ,?TRIP LIGHT L OF ® NEW CARBON MONOXIDE DETECTOR c r THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARES NEW SMOKE: DETECTOR THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND MEASUREMENTS IN THE FIELD AND BE RESPONSIBLE FOR FIT AND QUANTITY OF WORK. NO ALLOWANCES SHALL BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HIS PART. . C 2024 Thalheimer Architecture i(ol.011 GOLD BOND XP GYP.BE).WITH SPORSA (purple) I TILE FINISH to SOFFIT AND CEILING DOOR THALHEIMER 'JOLLY' TRIM AT ARCH I T E C T U RE ,11 DOOR JAMB DECORATIVE TWENTY ONE MIRROR CENTER STREET L TILE NORTHPORT NEW PORK 11768 VANITY TOILET Ll ----------—— 631 754 8621 L 5ATH # 1 SCAL E 1/2" -- 1'-0" NOTES 1) VANITY,COUNTERTOP,DECORATIVE MIRROR,TO BE SUPPLIED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR 2) ALL PLUMBING FIXTURES AND FITTINGS TO BE SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR, FOR PURPOSES OF BIDDING PROVIDE MATERIAL ALLOWANCE OF s 2000, 0 INCLUDING TAX AND DELIVERY 3) ALL BATH ACCESSORIES TO BE SUPPLIED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR TILE ON SHOWER WALL EX15TING WINDOW STONE SLAB AT WALL BEYOND 4) FINISH COLOR OF SCHLUTER 'JOLLY' TRIM TO BE SELECTED BY OWNER RECESS 5) TILE 15 SHOWN FOR GRAPHIC REPRESENTATION ONLY.FINAL LAYOUT, COURSING TO BE DETERMINED IN FIELD .SEE FLOOR PLAN FOR MATERIAL ALLOWANCE - - - �- -------4 -- - - ,� f-� TILE SHOWER ENCLOSURE STONE SLAB CAP LL- =11 0 AT WALL JAMB SHOWER VALVES @ @ TILED RECESS ON CONTROLS L J WALL BEYOND STONE SLAB SEAT WITH CONCEALED SUPPORT TOILET L STEP DN. INTO SHOWER L 0 U t41-411 GOLD BOND XF GYP.5D.WITH TILE iLL 6POF�GA (purple) FINISH ,@ SOFFIT AND CEILING CONTRO SEAT 'JOLLY' TRIM AT 1)V 2 ........ -D ARC, DOOR TILE RECESSED MMED. DOOR JAMB CAB SHOWER HEADS i TT- cSj 020C,5�) HEADS SHOWER 1EAT ENCLOSURE F N STONE SLAB CAP VANITY MED.CAB AT JAMB ------------ FINISHED TOILET BASEMENT lull I SCALE: 1/2"=1'-0" REV. DRAWN BY: J.E.T. REV. DATE. 18 APR 24 REV. GUEST 5ATH \112 SCALE : 1/2" -- 1'-0" PROJECT NO- 9 NOTES zn 1) VANITY,COUNTERTOP,RECESSED MED.CAB,STONE SLAB CURB CAP,WALL JAMBS, 4) ALL BATH ACCESSORIES TO BE SUPPLIED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR TILED RECESS SLABS,AND SHOWER SEAT TO BE SUPPLIED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR 5) EXACT LOCATION OF SHOWER VALVES AND HEAD TO BE LOCATED IN FIELD WITH OWNER PRIOR TO DRAWING 111"r ROUGHING OF 2) ALL PLUMBING FIXTURES AND FITTINGS INCLUDING SHOWER DRAIN TO BE SUPPLIED to D AND INSTALLED BY GENERAL CONTRACTOR. FOR PURPOSES OF BIDDING PROVIDE (6) EXACT SIZE OF TILED RECESS TO BE COORDINATED IN FIELD WITH TILE COURSING.OVERf9RAME AS MATERIAL ALLOWANCE OF f 4;000, INCLUDING TAX AND DELIVERY REQUIRED 3) SHOWER ENCLOSURE TO BE SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR 1) FINISH /COLOR OF SrHLUTER 'JOLLY' TRIM TO BE SELECTEE) BY OWNER THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE FRAMELESS DOOR AND PANEL,HINGES,CHANNELS.FULLS AS REQ. FINISH TO BE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS SELECTED BY OWNER No" PRISM CLEAR TEMP.GLASS. 5) TILE 15 SHOWN FOR GRAPHIC REPRESENTATION ONLY.FINAL LAYOUT, COURSING TO BE WILL BE PROSECUTED. DETERMINED IN FIELD .SEE FLOOR PLAN FOR MATERIAL ALLOWANCE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND MEASUREMENTS IN THE FIELD AND BE RESPONSIBLE FOR FIT AND QUANTITY OF WORK. NO ALLOWANCES SHALL BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HIS PART. C 2024 Thalheimer Architecture e � THALIIEIMER A R C H I T E C T U R E TWENTY ONE CENTER STREET NORTHPORT : NEW YORK �— — — 7 11768 [BEDROOM 15EDROOM 02 631 754 8621 III L I i I it O , Wo Lr - [BEDROOMS / I COST I -__ - - ION !-i - = - -- --= - - - d' - - -- STO - +-- —RDN C� IDEN EXI &TINC= x W S COI�I� f=L OOfi;;Z i=L AN 0 a W N 0 U I LIVING ROOM I I O PRIMARY BEDROOM KITCHEN - - �RED ARC, r , LIP AUK ND <�//PoRY O 1 O ----- UEI �20f SB OF NE`N - - - - - -- -- -- - - -- - O - - - °" _ - - - - -- - - - -- - FINISHED GARAG BASEMENT 0 0 0 SCALE: 1/8"=1'—O" REV. DRAWN BY: J.E.T. REV. DATE: 18 APR 24 REV_ I �'GST FL 00F�,> f=L AN N tH PROJECT NO_ 61) DRAWING Ab OF QID THESE PLANS ARE AN INSTRUMENT OF SERVICE AHD ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND MEASUREMENTS IN THE FIELD AND BE RESPONSIBLE FOR FIT AND QUANTITY OF WORK. NO ALLOWANCES SHALL BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HIS PART. C 2024 Thalheimer Architecture 53 .- A�5��3()RrLIENDL1E .T Site P I a n 9-1" -24 - OK- � i� SCALE I ' =30' - HE LE 5f F 1 l45• : '06 ��TT_.�.T:1IIEIMER e0o , RSCHECK INSPECTION CHECKLIST NOTATIONS : 2018 IECC CODE SECTIONS : SEC. 403. 3. 4 /; 4, x A A C H I T�El V, R DUCT TIGHTNE55 TEST RESULT OF LE55 THAN OR EQUAL TO 4 cfm/ 100 ft2 ACRO55 THE 5Y5TEM OR �_Y 1 SEC. 103. 1, 103. 2 THE55 THAN OR EQUAL TO 3 cfm / 100 ft2 WITHOUT AIR HANDLER e 25 Pa. FOR ROUGH IN TESTS, - a�'� �,• POOL Dr x ` TWENTY ONE CON5TRUCTION DRAWING5 AND DOCUMENTATION DEMONSTRATE ENERGY CODE COMPLIANCE FOR THE VERIFICATION MAY NEED TO OCCUR DURING FRAMING INSPECTION. 8*DL4.r 202 BUILDING ENVELOPE. THERMAL ENVELOPE REPRESENTED ON CON5TRUCTION DOCUMENTS. J�LTER O e•�risJ�aP ` ��r�ENr�R STREET °• 1 SEC. 403. 3. 2. 1 ' .09 ', NORTHPO SEC. 103. 1, 103. 2, 403. 1 AIR HANDLER LEAKAGE DESIGNATED BY MANUFACTURER AT LE55 OR = 2i® OF DE51GN AIR PLOW LOT 15a.,°'Y CONSTRUCTION DRAWINGS AND DOCUMENTATION DEMONSTRATE ENERGY CODE COMPLIANCE FOR NEW YORK LIGHTING AND MECHANICAL SYSTEMS. 5Y5TEM5 SERVING MULTIPLE DWELLING UNITS MUST SEC, 403. 1. 1 11768 DEMONSTRATE COMPLIANCE WITH THE IECC COMMERCIAL PROVISIONS, PROGRAMMABLE THERM05TAT5 INSTALLED FOR CONTROL OF PRIMARY HEATING AND COOLING ` 5Y5TEMS AND INITIALLY SET BY MANUFACTURER TO CODE 5PECIFCATION ' � c (� a 631 754 8621 SEC. 302. 1 e' Du. x a' r►at�P 403. 1 ® o o / 'ti r . HEATING AND COOLING EQUIPMENT IS 51ZED AS PER �ACCA MANUAL 5' 5A5ED ON LOAD5 SEC. 403. 1. 2 / cv 9 '6%ROOr DRAIN lit CALCULATED PER AC CA MANUAL 'J' OR OTHER METHODS APPROVED BY THE CODE OFFICIAL HEAT PUMP THEW05TAT INSTALLED ON HEAT PUMPS. PROPOSED FINISHED BASEMENT 4b �'�' g r,�A SEC. 402. ]. 1 SEC. 403. 5, 1 2,055 S.F. s o� CONDITIONED BASEMENT WALL INSULATION R - VALUE. WHERE INTERIOR INSULATION 15 USED, CIRCULATING SERVICE HOT WATER 5Y5TEM-5 SHALL HAVE AUTOMATIC OR ACCESSIBLE MANUALr, - o VERIFICATION MAY NEED TO OCCUR DURING INSULATION lN5PECTION. CONTROLS 3 � •�. 4�0 C4 PROPOSED BASEMENT SEC. 302. 2 SEC. 403. 6. 1 EGRESS WELL �� CONDITIONED BASEMENT WALL INSULATION INSTALLED PER MANUFACTURERS INSTRUCTIONS. ALL MECHANICAL VENTILATION 5Y5TEM PANS NOT PART OF TESTED AND LISTED HVAC EQUIPMENT ° 4' L.P. SHALL MEET EFFICACY AND AIR PLOW LIMITS. 4° fi'4 o � o ° Df" SEC. 402. 2. 9 133.92' 9.9' . CONDIITONED 5A5EMENT WALL INSULATION DEPTH OF BURIAL OR D15TANCE FROM TOP OF WALL N Atyr `Qo - s.�: $i.l SEC. 403. 5. 1, 1 rwb 4•11' SEC, 402. 1. 1, 402. 3. 4 HEATED WATER CIRCULATION SYSTEMS HAVING A CIRCULATION PUMP. THE 5Y5TEM RETURN PIPE 15 A oo 0 DOOR U-FACTOR SEE ATTACHED ENVELOPE ASSEMBLIES FOR VALUES DEDICATED RETURN PIPE OR COLD WATER SUPPLY PIPE. GRAVITY AND THERM05YPHON v° 's: ¢4sz / " rAa� a• nra. x�e .,gab � CIRCULATION SYSTEMS ARE NOT PRESENT. CONTROLS FOR CIRCULATING HOT WATER 5Y5TEM PUMPS Box cr�a:si.>< •7'.li oo ® iano SEC. 402. 1, 402. 3. 1, 402. 3. 3, 402. 5 START THE PUMP WITH SIGNAL FOR HOT WATER DEMAND WITHIN THE OCCUPANCY. CONTROLS 'e\®`�, •ram• . ,,.,Q� o c p UNM GLAZING U -FACTOR. SEE ATTACHED ENVELOPE A55EM5LIE5 FOR VALUES AUTOMATICALLY TURN OFF THE PUMP WHEN WATER 15 IN CIRCULATION LOOP AT SET-POINT ®�� Olt� � ��° TEMPERATURE AND NO DEMAND FOR HOT WATER EXISTS. �- SEC. 303. 1. 3 JfoN. N rri o'51" W 161.36" xoi U-PACTOR5 OF FENESTRATION PRODUCTS ARE DETERMINED IN ACCORDANCE WITH THE NFRC TEST "g ' LAND AVOW Olt FOR3[811MY OF PROCEDURE OR TAKEN FROM THE DEFAULT TABLE SEC. 403. 5. 2 or sotrr�roLD (RRC DEMAND RECIRCULATION WATER SY5TEM5 HAVE CONTROLS THAT MANAGE OPERATION OF THE PUMP s>�cJc;s igm) SEC. 402. 4. 1. 1 AND LIMIT THE TEMPERATURE OF THE WATER ENTERING THE COLD WATER PIPING TO 104. D, F. AIR BARRIER AND THERMAL BARRIER TO BE INSTALLED AS PER MANUFACURER5 INSTRUCTIONS. �+ SEC. 404, 1 MPS SEC. 402. 4. 3 90% OR MORE OF PERMANENT FIXTURES HAVE HIGH EFFICACY LAMPS. CLIMATIC ATIG G I IC IDESIGN CRITERIA FENESTRATION THAT 15 NOT 51TE BUILT 15 L15TED AND LABELED AS MEETING AAMA / WDMA / CSA / ALL WOW SHALL CGt'tPLY WITH THE REQUI NTS OF THE 2020 RESIDENTIAL BUILDING CODE OF NEW YOw STATE. 101/1.5.2 / A440 OR HAS INFILTRATION RATES PER NFRC 400 THAT DO NOT EXCEED CODE LIMITS. I. ALL REQUIRED INSPECTION5 BY THE GOVERNING MUNINCIPALITY BUILDING OFFICAL AS PER CODE wo DEISM SEISMIC SUBECT TO DAMAGE FROM WEIR ICE-BARRIER FLOOD AIR MEAN SECTIONS R104. 2. 1 THROUGH R104. 2. 5 SHALL BE SCHEDULED BY GENERAL CONTRACTOR AT DEs a DESIG1' uwDERLAY>ExT S FFM7MG AN�IJ& SEC. 402. 4. 5 APPROPRIATE TIMES DURING CONSTRUCTION. COORDINATE WITH BUILDING OFFICIAL. LOAD TaPcFECTSaIC SPEEGIO MIZISc CAtE u arEERIr F1aaSTL11 TEr�IITE REQUIRED apc TEMP. MN EFFECTS REGION DEBRIS XG4 DEPTH IG-RATED REGE55ED LIGHTING FIXTURES SEALED AT HOU5ING / INTERIOR FINISH AND LA5EL ED TO 20P.SF. t!"`l'°^ w No NO G. 3'-[�" T MODEf"T 13pEfx YES riO 5L9Deg. INDICATE LE55THAN OR EQUALTO 2. i0 CFM LEAKAGE AT 15 PA. 2. AIR LEAKAGE TESTING MUST BE CONDUCTED BY AN APPROVED THIRD PARTY TESTING ENTITY IN 130 MPH - -- ACCORDANCE WITH CODE SECTION R402. 4. 1. 2. A DETAILED WRITTEN REPORT OF THE TESTING SEC 403. 2. 1 ` - RESULTS MUST BE SUBMITTED TO THE BUILDING DEPARTMENT PRIOR TO FILING FOR CERTIFICATE OF CODE COMPL IANT STATEMENT H SUPPLY AND RETURN DUCTS IN ATTICS INSULATED GREATER OR = R-8 WHERE DUCT 15 GREATER OR OCCUPANCY. TO THE BEST of THE WERDIC44EDS IQJOWLEDGE,WOfRMATION AND FISSIONAL BELIEF,THE ATTACHED =3 INCHE5 IN DIAMETER AND GREATER OR = R-(o WHERE LESS THAN 3". SUPPLY AND RETURN DUCT5 IN CANSTRJCTION DocuI EWS MEET OR EXCEED THE MINIMUM REQUIEI;;VL tS of THE 2020 RESIDENTIAL CODE OF NEW YORK STATE AND THE 2020 ENERGY CC:NSERVATICN CGNSTRUCTION CODE OF NEW Yow STATE. OTHER PORTIONS OF THE BUILDING INSULATED GREATER OR = R-6 FOR DIAMETER GREATER OR = 3° 3. PRIOR TO FILING FOR A CERTIFICATE OF OCCUPANCY, GENERAL CONTRACTOR SHALL PROVIDE A AND R-4.2 FOR LE55 THAN 3" IN DIAMETER 'PERMANENT CERTIFICATE' TO BE P05TED ON A WALL IN THE MECHANICAL ROOM. THE-CERTIFICATE � SHALL PROVIDE ALL APPLICABLE VALUES FOR BUILDING INSULATION R-VALUE5, DUCT INSULATION SEC. 403. 3. 2 R-VALUES, FENESTRATION U-FACTOR5 AND SHGC, RE5ULT5 OF AIR LEAKAGE TESTING PERFORMED ON DUCT5, AIR HANDLERS AND FILTER BOXES ARE SEALED WITH JOINTS / SEAMS COMPLIANT WITH 2O20 THE BUILDING AND DUCTWORK, EQUIPMENT TYPES AND EFFICIENCY OF HEATING / COOLING / 5ERVICE RESIDENTIAL CODES OF NEW YORK STATE. WATER HEATING » SEC. 403. 3. 3. 5 BUILDING CAVITIES ARE NOT TO BE USED AS DUCTS OR PLENUMS SEC. 403, 4 4L N HVAC PIPING CONVEYING FLUIDS A50VE 105D. F. OR CHILLED FLUIDS BELOW 55D. F. SHALL BE � INSULATED TO GREATER THAN R-3 SEC 403. 4. 1 1. THE PROP05ED WORK ON TH15 5UILDING SHALL COMPLY WITH APPENDIX 'J' OF THE 2020 RESIDENTIAL PROTECT IN5ULAT101�1 OF HVAC PIPING BUILDING CODE OF NEW YORK STATE. SCOPE OF WORK UNDER APPENDIX 'J' 5HALL 5E CLA551FIED AS AN RED ARC y/ 'ADDITION' AND ALTERATION - LEVEL 2. WORK FOR 'ADDITION' SHALL COMPLY WITH SECTION AJ801, AND WORK �5�� PRE ry, • SEC. 403, 5. 3 FOR ALTERATION - LEVEL 2 5HALL COMPLY WITH 5ECTION AJ601. HOT WATER PIPES TO BE INSULATED TO GREATER THAN OR EQUAL TO R-3 2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2020 RESIDENTIAL CODE5 OF NEW YORK STATE, awl SEC. 403. E 2020 ENERGY CONSERVATION CON5TRUCTION CODE OF NEW YORK STATE. `��-yT 02068� AUTOMATIC OR GRAVITY DAMPERS ARE TO BER INSTALLED ON ALL OUTDOOR AIR INTAKES AND II II of N�� EXHAU5T5 3. ALL WORK SHALL COMPLY WITH GODS SECTION R310 FOR EMERGENCY ESCAPE AND RESCUE OPENINGS. SEE 4 VTR 4 VTR 4 VTR ROOF LOCATION5 ON FLOOR PLANS FOR 'EGRESS' OPENINGS. - JIL - - - aIL - - - JI - - - FINISHED SEC. 303. 1 ALL INSTALLED INSULATION f5 LABELED OR THE INSTALLED R- VALUES PROVIDED. 4. ALL WORK SHALL COMPLY WITH CODE SECTION R314 + R315 FOR SMOKE ALARM AND CARBON MONOXIDE I` 1 -TO EXISTING STACK VENT ALARMS. SEE FLOOR PLANS FOR LOCATION OF UNITS. I` I ABOVE To ROOF I EXISTING IEDTI INTO EExlari�S.CAD. BASEMENT SEC. 303. 2 I I --- APPROVED SANITARY SYSTEM WALL INSULATION SHALL BE INSTALLED A5 PER MANUFACTURERS INSTRUCTIONS 5. ALL WORK SHALL COMPLY WITH CODE SECTION R401 FOR FOOTINGS AND FOUNDATIONS. SEE PLANS AND BAR I BATH *1 BATH *2 j SCALE:AS 1VOTEDRE > s sEP 24 DETAILS FOR 61ZE OF FOUNDATION WALLS + FOOTINGS, STEEL REINFORCEMENT, DRAINAGE, DAMP PROOFING, ETC 2 New FIXTURES I 2 NEW FIXTURES 3 N>ew I=lxruREs 1 1 BATH 3 NEW FIXTURES SEC, 403. 3. 2 ( I 1 DRAWN BY: J.E.T. REV. 6. ALL WORK SHALL COMPLY WITH CODE SECTION M1201 FOR MECHANICAL CODE, CODE SECTION G2401 FOR FUEL F- - i - - - ►_- - F - 1- - - pUGTS SHALL 5E PRESSURE TESTED TO DETERMINE AIR LEAKAGE WITH EITHER: ROUGH IN TEST: . TOTAL LEAKAGE MEASURED WITH A PRE55URE DIFFERENTIAL OF 0.1 INCH w. ACROSS THE 5Y5TEM GAS CODE, CODE SECTION P2501 FOR PLUMBING CODE, CODE SECTION E3401 FOR ELECTRICAL CODE. I I 1 I i I I I I I I I DATE: 18 APR 24 REV. g wA pR I-i�2° 1 i-III I-IR I-i�2" I-IY2° I-I�2" 1 I I-I I-16r' I-IYZ" ' INCLUDING THE MANUPACTURER5 AIR HANDLER ENGL05URE IF INSTALLED AT TIME OF TEST. POSTCON5TRUCTION TEST: TOTAL LEAKAGE MEASURED WITH A PRESSURE DIFFERENTIAL OF 0.1 INCH I. ALL CONCRETE SHALL BE 3500 P51± 28 DAY STRENGTH � 5HCIWER � � 5HoPER w.g. AGRO55 THE ENTIRE 5Y5TEM INCLUDING THE MANUFACTURERS AIR HANDLER ENCLO5URE. BASEMENT -- --��� - - PROJECT N0. 8. ALL NEW FOOTINGS SHALL SEAR ON VIRGIN WITH AN ASSUMED 501L LOAD BEARING CAPACITY OF 2 TONS / S.F. 2 - 211 2111 EJECTOR EJECTOR 211 211 21& L 4" SOIL 4" 501L PUMP PUMP 4" SOIL 9. ALL STRUCTURAL FRAMING SHALL BE DOUGLAS FIR *2 AND BETTER 4" SOIL DRAWING O F Ur-1 15 INC= FZ 19 E FD1,y I AC= t-1 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS NOT TO SCALE WILL BE PROSECUTED. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND MEASUREMENTS IN THE FIELD AND BE RESPONSIBLE FOR FIT AND QUANTITY OF WORK. NO ALLOWANCES SHALL BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HIS PART. . C 2024 Thalheimer Architecture 10"POURED CONC.FOUNDATION WALL ON 24"x 12"CONC.FTG. (3)15 BARS CONT.o FTG. CEMENT STUCOO FINISH AT INTERIOR OF 6 x 6 A.Ca POST. i WELL.PROVIDE 2"STONE CAP AT WALL.4" i 1 ADJUST RO,OF EXISTING DOOR ABOVE PATIO. w t0 REMAIN As REQ. 36"HIGH BUILT IN p I CABINET WITH CLOSED PROVIDE 24"DEEP CLEAN GRAVEL At DOOR STORAGE BY BASE OF EGRESS WELL TO WITHIN 6"OF m I®�q n EXISTING STEEL COLUMN AND— ( OWNER _ WINDOW SILL 1._I_l.C\.1JIIEIlYlEJ_Z DROPPED STEEL BEAM TO �!! E REMAIN BLACK POWDER COATED ALUM.LADDER A R C H I T E C T U R 13 6 4 MOUNTED TO WALL As REa r� Y =TI 1 -1 1 19 -$ m n ix 4'-loll PROVIDE POWDER COATED ALUM HINGED SL/ ,� TWENTY ONE w I REMOVE PORTION OF FOUNDATI I GRATE COVER AT WELL �1 1®I� WALL FOR NEW FIXED WINDOW.FROM 1 CENTER STREET I PRIOR TO NEW FOUR DRILL HOLES IN 3 2 X 4 FURRING ON FLAT SILL PLATE TO NEW WINDOW SILL PATCH t0 MATCH AS REQ. EXIST.FOUND.FOR"5 KEBABS e 12"VAL. WITH W2"RIGID INSUL.STUN BAYS ' NORTHPORT PROVIDE TEMP.EXTERIOR FINISH ' , « :. OVER VAPOR BARRIER EXISTING STEEL COLUMN - ._ MODIFY EXISTING WINDOW NEW YORK ' REMOVE EXIST.WINDOW. AREAWELL AS REa DUE TO —OUTLINE OF EXIST.STEEL 2:_Sx�' $' Q SAWGUT EXISTING FOIA ID.WALL `n CONSTRUCTION 11768 COLUMN TO BE t FOR NEW EGFE55 WINDOW. X _: ... EXISTING IS�T EXTERIOR REMAIN. REMOVED `� Q 1' BLOCK IN RO.WIDTH AS REQ -, Ili � EXISTfNCa WINDOW TO REMAM ?., \ 631 754 8621 G ATION W m Q III +/�� _ ( —lu ADD OWN TO END OF WALL AS b �� GUEST \ ` R EQ.TO CONCEAL COLUMN ,xu _ -- - ALIGN WALL \ FINISHED STORAGE 2_a'x 6:_a: ►► _ �-to C o fi' .. WITH COL. w Iil NEW 312" ID.STL.PIPE COL OWN = 2 I _� _ N w U_F , 30"x 30"x 18"CONC.FTG.(3) � � ( �a t� " 2'-4", &'-6 +� ? 2 'S BARS EACH WAY.SAWCUT Eta �`` 2'_Ou a-.- o P ' f2O'-On 4° $'-11� 4° _ 4'-4° 3 xlsT. x ua o`n ( 3 SLAB AND PATCH AS REQ a HOT BAR AN RT n'Q a _ COLUMN REMOVE EXISTING COLUMN �D ATN VENT EXHAUST S� T� \\ ,- REMOVE EXISTING I APPLIANCES BY OWNER " $�' I -1 r-4""6'-S" = I, I I i- __ _ _ _ = 1 NEW 31/z" ID.STL.PIPE COL ON - FAN t0 \ a �----- 30"x 30"x 15"CONC,FTG.(3) EXTERIOR PAD OUT WALL TO ENCLOSE A ,a 'i - - EXIST.(2)14"MICROLAM FLUSH BEAM TO REMAIN= - 1-- T a !! S BARS EACH WAY.SAWCUT _ \ W EXISTING ELECTRICL AND AN L _I VERIFY IN FIELD L J I I— 3 PANELS.PROVIDE CONGEALED 3 _ SLAB AND PATCH AS REQ <i 9 HINGED FLUSH ACCESS PANELS � � - _ 0 WITH EDGE PULLS.VERIFY SIZE EXISTING STAIR AND _ It IN FIELD RAILING TO REMAIN I 2 I cv ( , �6„ AC 1 m RLOCATED (;HIT \ a —,_ J , ` v; EXISTING DEHUMIDIFIRE AND d. CUT BAM WALL TO 3 I `� ;o+ I:' CONDENSATE PUMP MECN. \ DW. ICES EXISrfNG STEEL m ' ' v v v RELOCATED COLUMN I +� s+ ++� s* s+� s+ — WATER HEATER `\ VENT EXHAUST ,� s, -- EXIST m FAN TO >Ac EXTERIOR 2'-4"x : &,, lAflT ,4T�-I3*\ e+aEt ves n n - II a WAIST NEW WOOD FRAME WALL AS \ -9 4 -� 4 WATER TIGHT TO FOUNDATION A5 C POSSIBLE AND STILL \ I � A� TN i _, REMOVE AND RELOCATE — c�a PIPE 6'-2"N.T. CONCEALING SOIL LINE S7% EXISTING DEDICATEDFAN TO r VENT EXHAUST ^\. DEHUMIDIFIER AND EXTERIOR - 0 ---- CONDENSATE PUMP. COORD. 2'-4"x 6'-S" NEW LOCATION WITH OWNER EEP PROVIDE ADEQUATE ,�'�, EWCH TYPICAL PERIMETER WALL SERVICE ACCESS AND t VENTILATION TO EXISTING VAPOR BARRIER OWN FOUND,WALL LEGEND 2 x 4 WOOD STUDS 16"O.C. EQUIPMENT. Y.lE, k, EXISTING EGRESS c'� WINDOW AND WELL TO METAL SILL PLATE SLEEVE ell REMAIN ^ R-15 BATT INSULATION NEW WALL CONSTRUCTION No"GYP.BD.FINISH 4" : 2 x 4 STUDS 0 IV' O.C. 6" : 2x6 STUDS 016" O.C. NO TN PLAN FOR ALL 0 PROPOSED CEILING HEISEE ELECTRICAL AND GHTS CAND SOFFITED TS. COORDINATE ALL IN NOIES� SCALE : 1/4"=1'-0" SOUND MITIGATION WALL 3 FIELD PRIOR r0 STARTING ELECTRICAL ROUGH IN 1. EXISATING GYPSUM BOARD FINISHES AT CEILING SHALL BE REMOVED AS REQUIRED TO COMPLETE PROPOSED WORK OR AS REEQURRED FOR ACCEPTABLE LEVEL rrTT�1 CEILING FINISH. VERIFY IN FIELD. W EXISTING FOUNDATION WALL 2. AT ENTIFS BASEMENT FLOOR WITH EXCEPTION OF MECHANICAL ROOM,GENERAL CONTRGATOR SNALL PREP EXISTING SLAB AS REQUIRED FOR CERAMIC TILE PLANK FLOOR,MUD SET. FOR BIDDING PURPOSES PROVIDE MATERIAL ALLOWANCE OF 0 r3.001 S.F.INCLUDING WASTE,GROUT,TAX AND DELIVERY. COLOR OF GROUT TO BE SELECTED BY 011 NER.USE SAME ALLOWANCE FOR THIN SET TILE WALLS AS SHOWN IN BATHROOMS. 3. ALL NEW INTERIOR DOORS AND HARDWARE SHALL MATCH EXISTING AT FIRST FLOOR IN TYPE,STYLE AND FINISH. © CARBON MONOXIDE ALARMS SHALL BE �✓ PROVIDE PRIVACY LOCKS AT GUEST AND BATHROOM ENTRY DOORS PROVIDED IN ACCORDANCE WITH 2020 _ ^ PROVIDE DUMMY TRIM AND MAGNETIC CATCHES AT DOUBLE SWINGING CLOSET DOORS. R-CN.Y.S. PROVIDE FLOOR OR WALL MOL.'NTED DOOR STOPS AS MQUIRED. g SMOKE ALARMS SHALL BE PROVIDED IN No UPPER CABINETS = W 4. ALL NEW BASE TRIM,DOOR AND WINDOW CASING SHALL MATCH EXISTING At FIRST FLOOR IN SPECISES,PROFILE. VERIFY IN FIELD O ACCORDANCE WITH 2020 RCN.Y.S, Q 5. EXTEND EXISTING HOT WATER SERVICE SYSTEM TO ADDITIOANL FIXTURES A5 SHOWN. VERIFY ADEQUACY OF EXISTING SYSTEM IN FIELD. COORDINASTE WITH +`; OWNER WHETHER R MIRN CIRCULATING SYSTEM IN BATH 02. ICE 6. COORDINATE WITH OWNER TYPE OF H.VA.C.SYSTEM r0 BE INSTALLED IN ANY. ALL NEW RVA.C.WOW SHALL COMPLY WITH STATE CODE AND 2020 N.Y.SE.CLL. '1. ALL NEW WINDOWS SHALL BE JELD-WEN TO MATCH EXISTING SERIES WINDOWS.ALL HARDWARE AND FINISHES SHALL MATCH EXISTING. ALL NEW WINDOW SIZES SHALL BE COORDINATED WITH OWNER PRIOR TO ORDERING. 5AE ELEV. 3 `� Q N I J EXTERIOR WALL EXIST.FLOOR JOISTS CONSTRUCTION CLIP CONNECTION To V.I.Q. �C BEAM i II OVERFRZAME AS REQUIRED ¢ FtED A,q ALUM.POWDER COAT _ cy G•�.� HINGED GRATE MICROLAM HEADER SEE PLAN Q9 pRD Tye r 2"x2" TUBE FRAME W1 2"x2"xIl4"GRID INFILL 5 ATI� PROVIDE HOLD OPEN GYM C DEVICE 6 WALL I ` 5 X im X I/1 WELDED ON N 2 THK BLUESTONE CAP BEARING PLATE W/(4)1/2 DIA. T O 6 GRAWLSPAGE WELL BOLTS PER COLUMN ; ; ,,, ,,; TILED WALL F N�`N (_J _� �- t1 -D LEAVE INSIDE EDGE C 31/2" DIA.STEEL PIPE COL. 9 FOUND, OS TO 4 D.EXPOSED , �1 t NON - ADJUSTABLE LINE OF RECESS FINISHED TU.SUBFLOOR d- Q ACCEPT COVER GRATE r � .. .s --� ALUM.F .ME � OP NING ° BASEMENT CEMENT PARSE FINISH _ WALLS t PATCH FLOOR TO MATCH .. EXIST. . STONE B SH VINO ' � EL TO FUL L LL WAL TN L DERV A I N ::. LG r 1!_ W/ TILE COURSING. SCALE:AS NOTEDREV. 13 JUN 24 m ' EGRESS WINDOW.SEE SAW-CUT EXIST. CONC.SLAB ' ' R G. PLAN FOR SIZE I STUDY N :" `` VER(1=1' INFIELD ° EXIST SLAB DRAWN BY: J.E.T. CONC.FOUNDATION At E w ': REV. 15 SEP 24 >� FRAMING 4 WALL : 2 x 4 WOOD STUDS 16 OZ. WELL TILE RECESS TO q ;. �( E' ALICaHN W/ WALL E: 18 A ° T.O.FUN.FLOOR R. V d ' EL. t100'-0" = �6"WALL : STAGGERED 2" x 4" WOOD STUDS � COURSING. VERIFY IN 4 12" DEEP CLEAN a „ „ „ 16 O.C.ON 2 x 6 PLATE FIELD e 8 X 10 X 3/4 WELDED ON ----- - --- ' BLUEStONE GRAVEL ,, .. O BEARING PLATE INSULATION 2iz" SOUND ATTENUATION BATT INSULATION BY 'ROXUL' TO FILL STONE SLAB STUD CAVITY s% ;; PROJECT NO. CONC.FOOTING INTERIOR PERIMETER Q A e 4 POWDER COATED ALUM I ° ° . 4 (SEE PLAN FOR SIZES) FINISH Nil' %` OF RECESS. �, m TUBULAR LADDER EACH WAY BAN /LAUNDRY PROVIDE a GOLD BOND XP GYPSUM ANCHORED TO WALL 5 REBAR5 12 O.C. AT R Q at!" WONDER BOARD 4 .4 j -' 2 � PITCH BOTTOM � .. BOARD WITH SPORGARD (PURPLE) WALLS TO RELIEVE STONE OR TILE, r SHELVES OF RECESS T.O.SLAB 4 — DRAWING v ,. E ° TO PROVID <F UNDISTURBED SUBGRADE 5 , A OF BEDROOM /PUBLIC SPACES PROVIDE !a GOLD BOND DRAINAGE 2 TON MIN.BEARING CAPACITY GYPSUM BOARD AS BASE LAYER AND Na"GOLD BOND 4 d SOUNDBREAK AS FINISH LAYER INSTALLED AS PER MANUFACTURERS SPECIFICATIONS. ° a it ° THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE ZF I �"'� ( THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WELLETAIL r2_-� TYFICAL DETAIL DETAIL T SOUND RESISTANT L 4 �I M- D TA 1 L WILL BE PROSECUTED. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND 3 �� - ' " 3 SCALE : 3" - 1'-m"SCALE : 3/4" = i'-O" 3 SCALE : 3/4" = 1'-O° SCALE : 3 - 1-m - MEASUREMENTS IN THE FIELD AND BE RESPONSIBLE FOR FIT AND QUANTITY OF WORK. NO ALLOWANCES SHALL BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HIS PART. . C 2024 Thalheimer Architecture 1 1 Ll qp qp THALITEIMEIT A R C H I T E C T U R E TWENTY ONE r co Q j 1 \\` I CENTER STREET SUM ��� -----,� ❑ ; NORTHPORT \ \\ NEW YORK 1176B 1 I I / Z 631 754 8621 i GUESTi / \` t Ell CLG C G CLCs GLCz t1 CLGCLCs ro®" ��iqp �(9 D D C 01 GYM NEW LIGHTS AT STAIRWELL TO BE \ \` WIRED t0 MOTION DETECTOR AND \A \\ /, \\` \ A i EXISTING SWITCH IN BASEMENT GLG --- - \ CLG CLG �\ C G - \ ©�� w� --� O ` ` \ RELOCATE CEILING MOUNTED ROUTER A Q_ A A \ J' cLv__ _ ,4 �� cL� P-- ---- _ / \ \ \t u 5 m ODD �� \ �� EXISTING ELECTRICAL AND A/V PANELS. A - �- D ---------- \ s ELVES I us 3 /3 usE3 u A --J� A PROVIDE CONCEALED HINGED FLUSH \ D D ACCESS PANELS WITH EDGE PULLS.VERII Y Lu \\\ Lu A _ SIRE IN FIELD _-_ t — -----,_ ✓J r— n � n n u � —_—����/ !(o',�I0J �t�' 11" \ IANIT \ \ \ \\\ ^ t9'-(d 6-10 t6-10 t i'-il t 1 Il 6'-1@ GLCs CLG CLG C' �' GLCx` CEG -TO EXIST.LIGHTSrz \ ----- Diu.— — — — — —1fr- 7F �— — ABOVE �g i g ------ - EXISTING GYPSUM BOARD D �-'''--.. D D D Lute r CEILING IN MEGN.ROOM �E -} I I, 1, I Ar, I d s+�1"LvEs I C C C I urdlr I �\ �` --� IT A7 t8'-8"AFF. PROVIDE POWER TO NEW EJECTOR PUh1I'AS E A REQUIRED SOFFIT AT 01-11°AFF. r ^ PROVIDE POWER TO NEW \ �j EJECTOR PUMP AS REQUIRED GAR&rgE AN p� 6. NO �-T ELECTRICAL SD REFLECTEDCEILING AN r ., NO a S 1. LOCATION OF ALL INDICATED CEILING DROPS,SOFFITS TO BE VERIFIED IN FIELD PRIOR TO START OF ELECTRICAL ROUGHING. 2. PROVIDE ACCESS PANELS AT ALL MECHANICAL VALVES,ELECTRICAL BOXES,ETC,AS REQUIRED. 0 3. ALL FINISHED CEILINGS TO BE b/e,-GYPSUM BOARD.PROVIDE M.R.BOARD IN BATHROOMS. r , M--I IELECTRICAL NOTIES0 DUPLEX RECEPTACLE I ALL WORK. SHALL CONFORM TO N.E.C., AND THE 2020 E.C.C.CN.Y.S. ALL WIRING QUADPLEX RECEPTACLE SHALL BE COPPER. RED ARC, 1 DUPLEX G F I RECEPTACLE PROTECTED 2, GENERAL CONTRACTOR SHALL PROVIDE AIR-TIGHT SEAL HOU51NG5 AT �� PAS ryq RECE55ED FIXTURE5 AS REQUIRED BY CODE. `�� ja AT PANEL LuM LED TAMPER RE515TANT DUPLEX OUTLET 3, ALL FIXTURES AND LAMPS TO BE SUPPLIED 4 INSTALLED BY GENERAL LIGHTINGT L WITH NIGHTLIGHT BY LEGRAND 0 NTL $55 TR CONTRACTOR EXCEPT A5 NOTED. �9 o2osa�MANUFACTURER GAT. NO. R=MA S 0 __------ F N � DEDICATED RECEPTACLE AT PANEL 4. EXACT LOCATION OF ALL FIXTURES, SWITCHES AND DEVICE5 SHALL BE A FIXTURE AND LAME' TO BE SUPPLIED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR u55 RECEPTACLE WITH U55 CHARGER DETERMINED IN FIELD BY OWNER PRIOR TO ROUGH IN. B LEVITON KEYLESS 25 W 2100 K LED SURFACE MOUNTED WHITE PORCELAIN SOCKET LEVITON MODEL # T 5632 C WAC WS - 248 30 W 2100 K LED 48" WALL MOUNTED CLOSET LIGHT FINISHED HEIGHT TO BE VERIFIED IN FIELD 5, ALL OUTLETS, SWITCHES AND DIMMER5 SHALL MATCH EXISTING AT FIRST D FLOOR OF HOME. ALL DIMMERS SHALL BE 'UNIVERSAL' ELCO - KOTO SERIES E3LKt-,51CA HOUSING / ELK 0�2-( MODULE / ELK 3618W TRIM 10 W 2�00K LED PEX 3 ROUND DOWNLICx+�I" FIXED BASEMENT NEW 5WITCH / 5INGLE POLE E ELCO - KOTO SERIES E3LKro5ICA HOUSING / ELK 0921 MODULE / ELK 3618W TRIM 10 W 2100 K LED PEX 3" ROUND DOWNLIGHT WET LOCATION 6, ALL LED LAMPS SHALL BE 2100K / WARM WHITE UNLESS NOTED OTHERWISE F NUTONE XN 110 ULTRA GREEN ------------- EXHAUST FAN - ro" D IA. DUCT 3 NEW SWITCH / 3-WAY LEDI V5 - SPEC - 1.5 - 30K - LENGTH - CHI - 5Q - F 1.5 W 2-100K LED LED STRIP LIGHT WITH SLIM STANDARD CHANNEL / FROSTED LENS NEW JAMB 5WITCH IN SCHEDULE. SCALE: v4"=i'-o" REV. 13 .rUN 24 NEW SWITCH / TIMER (5-10-15-30) �. GENERAL CONTRACTOR SHALL 51ZE ALL DIMMABLE MAGNETIC POWER DRAWN BY: J.E.T. REV.=SEP T SUPPLY UNITS AS REQUIRED FOR LOADING. DATE: is APR 24 REV. D NEW DIMMER / 600 WATT g, ALL PROP05ED GFI OUTLETS/ CIRCUITS IN KITCHEN AND BATHS SHALL BE <> NEW RECESSED LIGHTING FIXTURE PROTECTED AT PANEL. Q NEW SURFACE MOUNTED LIGHT FIXTURE PROJECT N a. L :� L CONTINUOUS STRIP LIGHT DRAINING L Q NEW CARBON MONOXIDE DETECTOR OF RO Q NEW SMOKE DETECTOR THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT. INFRINGEMENTS WILL BE PROSECUTED. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND MEASUREMENTS IN THE FIELD AND BE RESPONSIBLE FOR FIT AND QUANTITY Of WORK. NO ALLOWANCES SHALL BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HIS PART. C 2024 Thalheimer Architecture