Loading...
HomeMy WebLinkAbout49375-Z �SUEFOl Town of Southold 3/9/2024 �. . P.O.Box 1179 co �. 53095 Main Rd oy'�j0 ao� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 45034 Date: 3/9/2024 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 2760 Yennecott Dr, Southold SCTM#: 473889 Sec/Block/Lot: 55.-4-35 Subdivision: Filed Map No. Lot No. conforms substantially to the.Application for Building Permit heretofore filed in this office dated 6/13/2023 pursuant to which Building Permit No. 49375 dated 6/13/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for ' which this certificate is issued is: addition and alterations for finished basement to existing single family dwelling as applied for. r � The certificate is issued to Michel,Matthew&Johnson,Kirsten of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49375 1/22/2024 I ' PLUMBERS CERTIFICATION DATED 1/18/2024 J,oe rranova Au one nature �SUFFot,��o TOWN OF SOUTHOLD moo. ay BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE "oy • o�� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49375 Date: 6/13/2023 Permission is hereby granted to: Michel, Matthew 2760 Yennecott Dr Southold, NY 11971 To: construct alterations (finish basement) to existing single-family dwelling as applied for. Replaces BP 46164 At premises located at: 2760 Yennecott Dr, Southold SCTM # 473889 Sec/Block/Lot# 55.4-35 Pursuant to application dated 6/13/2023 and approved by the Building Inspector. To expire on 12/12/2024. Fees: RENTAL PERMIT $449.80 Total: $449.80 Building Inspector �o�gUffO��co TOWN OF SOUTHOLD ay BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46164 Date: 4/29/2021 Permission is hereby granted to: Michel, Matthew 2760 Yennecott Dr Southold, NY 11971 To: construct alterations (finish basement) to existing single-family dwelling as applied for. At premises located at: 2760 Yennecott Dr, Southold SCTM #473889 Sec/Block/Lot# 55.4-35 Pursuant to application dated 4/22/2021 and approved by the Building Inspector. To expire on 1012912022. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $849.60. CO-ALTERATION TO DWELLING $50.00 Total: $899.60 Bu in or o��OF SOUjyol h O Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 ;4`0 �� sean.devlinl town.southold.ny.us ���DUNT`I BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Matthew Michel Address: 2760 Yennecott Dr city:Southold st: NY zip: 11971 Building Permit#: 49375 Section: 55 Block: 4 Lot: 35 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: REP Electric License No: 46288ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 22 - Ceiling Fixtures 2 Bath Exhaust Fan 1 Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 1 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 31 CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO 1 Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 7 4'LED 2 Exit Fixtures Sump Pump 1 Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " Finished Basement Inspector Signature: Date: January 22, 2024 S.Devlin-Cert Electrical Compliance Form ;r ��c�t�fFO�K�o Town Hall Annex Telephone(631)765-1802 54375 Main Road ;c P. O. Box 1179 Southold, NY 11971-0959 • I� ((� L; U is 0 V E - 2024 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: ( 2- Building Permit No. Owner: V1/lA-TT M 1G6f4.t;L—S (Please print) Plumber: �o�'���1�(G� 4A (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. Q� (Plumbers Signature) Sworn to before me this �O day o 20 cK Notary Public,Sttxe-j; County JENNA KOCKENMEISTER NOTARY PUBLIC,STATE OF NEW YORK NO.01KO6402096 QUALIFIED IN SUFFOLK COUNTY MY COMMISSION EXPIRES DECEMBER 23,2027 1 �o�aOF SOUIyo� - — # # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm, 631.765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] " I ULATI�TION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 'C [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: a o"k. -, GIL4Z DATE INSPECTOR SOGIyo � 700 # TOW OF SOUTHOLD BUILDI G DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) �SELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: of�� 4 le Q, �2/�at/l�� ArcLvl� / obe,—rc�a,41' r i" A avg,�tz,&Av ot�) R DATE INSPECTOR �aOE SOUIyO # # TOWN OF SOUTHOLD BUILDING DEPT. cou 631-765-1802 INSPECTION [ ] - FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL h h [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ f I REN,JTA,,LL REMARKS: (/� r2d4 vnu'tm c,�l L UI DATE INSPECTOR %f SOblyO6 t # # TOWN OF SOUTHOLD BUILDING DEPT. °��couxn ' 765-1802 INSPECTION —C [ ] FOUNDATION 1ST [ ] ROUGH PLBG. ,[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE`&CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] . FIRE RESISTANT-CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE ��— INSPECTOR �e " E C E � V E N. J. MAZZAFERRO, P.E. .MAY, - 9.2022 BUILDING DEPT. PO Box 57, Greenport,N.Y. 11944 TOWN OF SOUTHOLD Phone - 516-457-5596 Consulting Engineer May 9, 2022 Design, Construction, Inspection Page 1 of 1 Town of Southold-Building Department 53095 Main Road PO Box 1179 Southold NY 11971 Re: Michels 2760 Yennecott Drive Southold,N.Y. 11971 District-1000, Section-55, Block-4, Lot-35 Building Permit Number—46164 -Alterations On May 7,2022, I inspected the insulation installed at the noted location. The inspection covered the walls of the basement. The inspection results are: 1 —Walls—Insulation provided and installed by Owner. Insulation provided rated as R- 18. The insulation included a rigid foam board rated at R-5 and fiberglass batts rated at R-13. The insulation provided was done in compliance with the applicable sections of the IRC,NYS and Southold Town Building Codes. 2—Ceiling—Insulation provided and installed by Owner. Insulation provided rated as R- 13 and was installed for sound reduction only. Result- The insulation installation as verified by inspection on May 7, 2022, is compliant with all applicable codes and conforms with the design specifications. Nicholas J. Mazzaferro,P.E. o 0 HO 0570 AR OFESSIOPIP�'�C. OD e, 'PUVE U UMAY N. J. MAZZAFERRO, P.E. BUILDING DEPT. PO Box 57, Greenport,N.Y. 11944 TOWN OFSOUTHOLD Phone - 516-457-5596 Consulting Engineer May 9, 2022 Dew, Construction, Inspection Page 1 of 1 Town of Southold-Building Department 53095 Main Road PO Box 1179 Southold NY 11971 Re: Michels 2760 Yennecott Drive Southold,N.Y. 11971 District-1000, Section-55, Block-4, Lot-35 Building Permit Number—46164 -Alterations Inspection—Framing On May 7, 2022, I inspected the construction at the noted location. The inspection covered the framing for the alteration to the existing structure. The areas inspected included the basement of the existing house. The framing work included and interior walls and ceilings and the new openings to the exterior. The inspection results are: Items inspected included lumber type/grade,lumber size, dimensional spacing, framing connections, header sizes, bearing, and integration with the concrete floor. The framing work was done according to approved plans and in compliance with the applicable sections of the IRC,NYS and Southold Town Building Codes.' Result—Based upon inspection of this project and to the best of my knowledge,belief and professional judgment, construction as installed complies with the plans and applicable codes of the IRC,NYS and Southold Town Building Codes. F P * O q Nicholas J. Mazzaferro,P.E. cc 0 2 2� �Fp No 0570°�� AROFEsslot% �� E C E � V E MAR DD N. J. MAZZAFERRO, P.E. TOWN'OFSOUTHOLD PO Box 57, Greenport,N.Y. 11944 Phone - 516-457-5596 Consulting Engineer March 12, 2022 Design, Construction, Inspection Page 1 of 1 Town of Southold-Building Department 53095 Main Road PO Box 1179 Southold NY 11971 Re: Michels 2760 Yennecott Drive Southold,N.Y. 11971 District-1000, Section-55, Block-4, Lot-35 Building Permit Number—46164 -Alterations Inspection—Rough Plumbing On March 12, 2022, I inspected the construction for the alterations at the noted location. The inspection covered the interior plumbing roughing for the Drainage Waste and Vent System(DWV) and the Water Supply System(WS). The inspection results are: 1 —DWV— System was fully exposed and readily viewed. I observed all drainage and vent lines. System constructed as required.New installation will be connected to the existing system using an ejector pump. All construction was done in compliance with the applicable sections of the IRC,NYS and Town of Southold Building Codes. 2—WS—System was fully exposed and readily viewed. I observed all hot and cold water supply lines. System constructed as required. All construction was done in compliance with the applicable sections of the IRC,NYS and Town of Southold Building Codes. Result—Based upon inspection of this project and to the best of my knowledge, belief and professional judgment, construction as installed complies with the plans and applicable codes of the IRC,NYS and Southold Town Building Codes. y�P�E O NSW y0 F Nicholas J. Mazzaferro,P.E. ° • 051 AROFESSIONP�"� JAMES J. DEERKOSKI P.E. 260Deer Drive Mattituck,NY 11952 (631) 774 7355 Date: July 12, 2023 S JUL 1 3 2023 T To: Town of Southold Building Dept. BUILDING DEFT. Re: Foundation Inspection Permit#49375 Matt Michaels 2760 Yennecott Dr. Southold,NY To Whom It May Concern: This letter certifies that Footings, Foundation, and Damp proof inspections were performed on the above mentioned Dwelling and all work was installed as per plan and as Per New York State Building Code. Any questions feel free to call. Sin erely, OF NFL J es Deerkoski P.E. n M to NCO .off •502 ��SS P J N CD CCN J K CV N pp �p x fu i t, it so _ r _ _ r. i u' ® was I S 1 'f i 1 FOR in a 191 st 1r�i wo.is ,� C1it , r`°► , '� i sOJs ,FN • ► ��.� 111 W - - Z U Y 1ifi"S 4 R 0 '..� �.1. K•1.i K 4 1'� /Y M i � TOWN OF SOUTNOLD BUILDING DEPT- � 631-765.1802 INSPECTION [ j FOUNDATION 1ST [ ] ROUGH PLBG. [ j FOUNDATION 2ND [ ] INSULATION/CAULKING [ j FRAMING/STRAPPING [ ] FINAL [ j FIREPLACE & CHIMNEY [ ] FIRE SAFETY IN SPECTIOI [ J FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATIO [ j ELECTRICAL (ROUGH) [ j ELECTRICAL (FINAL) [ j CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: E INSPECTOR i f VIIM itr qua: � ► w --� _ Mk ..it tIj FOUNDATION(IST) • • e INSULATION.PER N.Y. STATE ENtRGY CODE rim, Waj=wlA- . De • e i WW�Twmps,V, ,' i. i� •i lI � �1 r�il � • 1 ,ECTIONREPORT 'DATE CONIIVINS FOUNDATION(1ST) • .. '�•v�'_.�: tw•;i:i"��.:�:.'.11', �'..ua& ►CMhest . � '>'A x,•ke 3>Jat �'„- .., ''r 1, FOUISDATION(2NA) ' '.� .:}i.1.'_y1;' -`�C.t',�.{t� b AYxy. F 'tl.'4•:hb5�+ '�{; 9- .' o '� y�i-,• t {+�iuit' .x.��s �, ,N N:�L�nT�=rn iyr`y✓'.�:., J � ` �P .ROUGHFRAMING'& ,';: • I�GI�G(l�i' n;, '.;/'�'-•:�;�/�v,e� 'i�3:•:S �h.. Ni.,i's�{`^•� 'a� `.A i�`vi^' ^� ZeA #� r, +s ; INS UL. STATE CIO f sow { �l n'-/ - - AgA FINAL.. ADDITIONAL COMMENTS' . C� to 15 too 02 2� -1 eack E\ IL z o5ur> c��p` TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax (631) 765-9502 htti)s://www.southoldtownnyjzov Date Received APPLICATION FOR BUILDING PERMIT _ For Office Use Only + PERMIT NO. Lt Building Inspector: APR _ 9 2021 Applications and forms must be filled out in their entirety.Incomplete ;. *� DEPT. applications will not be accepted. .Where the Applicant is not the owner,an Owner's Authorization forin.,(Page 2)shall be.completed. " Date: (�.a o a-t OWNER(S)OF PROPERTY:.' Name: SCTM#1000- Physical Address: a t)4-" 1 Phone#: Email: Mailing Address: CONTACT PERSON:' Name: a� -b Mailing Address: Po t��xI 5c��Sow44tp_l� Phone#: ,I- �3 �f 7 Email: J w _��o�.25i _�S 1_V►c� �t,(��o.God DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name I�• Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSEDCONSTRUCTION ❑New Structure ❑Addition Zrnll eration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other -Pi2o�� 15" I20-S- $ Will the lot be re-graded? ❑Yes Will excess fill be removed from premises? ❑Yes fo 1 PROPERTY INFORMATION Existing use of propertySlVl�Ie 2S1 intended use of property: s � Zone or use district in which premises is situat-tl: Are there any covenants and restrictions with respect to (�— ( {0 this property? 0Yes ! o IF YES,PROVIDE A COPY. CSKk flax Atty Reading,: nw owner/contracts/design professional Is rersponubie for all drainage and storm water Issues as provided by clsiptar 235 at the Town code. "PUCAT1oN is trutloy MADE to the Building Department for the Issuance of a Building permit pursuant to the Building Zone ordinance of the Town of Southold,Suffolk,County,New York and other applixable laws,ordinances or Regutabions,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all appticable taws,ordinances,building code, housing code aid regulations and to admit authorized inspects on premises and In buildirigis)for necessary Inspections.False statements made herein are Mmhhabin as a class A misdemeanor pursuant to Section 210.45 of the New York State penal Law. Application Submitted By(print name): �w �✓ OAuthorized Agent ❑Owner Signature of Applicant: Date: .'p-oa-74 CONNIE D.BUNCH STATE OF NEW YORK) Notary Public,State of New York S No.01 BU6185050 COUNTY OF v 0 ) Qualified in Suffolk County Commission Expires April 14,20'L� being duly sworn,deposes and says that(s)he is the applicant (Name of individual si ning contr ct)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this11, L&n�L- OAclayof 20 l Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) A A w f 1� M. residing at 7 (o ycv,xc ( off Of ve /"' � � � do hereby authorize NA I y o V y f l to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature ate Print Owner's Name 2 UILDING DEPARTMENT-Electrical Inspector Gy14PR 2 5 2022 TOWN OF SOUTHOLD biLDING utpT . townHall Annex - 54375 Main Road - PO Box 1179 o ® P�N OF SOUTHOLD Southold, New York 11971-0959 -x �}y Telephone (631) 765-1802 - FAX (631) 765-9502 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 4/20/22 Company Name: REP Electric LLC Electrician's Name: Robert E Paladino License No.: 46288ME Elec. email:repelectricl @gmail.com Elec. Phone No: 631-767-6034 [D I request an email-copy of Certificate,of Compliance Elec. Address.: PO Box 635 Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Matt Michels Address: 2760 Yennecott Dr Southold Cross Street: Boisseau Ave Phone No.: 631-767-6034 Bldg.Permit#: 46164 email:mjmichel83@gmail.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Finished Basement Square Footage: 1125 Circle All That Apply: Is job ready for inspection?: ❑ YES ❑✓ NO F Rough In ❑ Final Do you need a Temp Certificate?:, ❑ YES F NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 FJ2 0 H Frame D Pole Work done on Service? 0 Y N Additional Information: PAYMENT DUE WITH APPLICATION C 'WILDING DEPARTMENT- Electrical Inspector t APR 2 5 2022 TOWN OF SOUTHOLD , own Hall Annex - 54375 Main.Road - PO Box 1179 au�LairvG�ci�r. ,jam f OWU OF SOUTHOLD Southold;,New York 11:971-0.959 41 Telephone (631) 765-1802 - FAX (631) 765-9502 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 4/20/22 Company Name: REP Electric LLC t Electrician's Name: Robert E Paladino License No.: 46288ME Elec. email:repelectricl @gmail.com Elec. Phone No: 631-767-6034 01 request an email copy of Certificate of Compliance Elec. Address.: PO Box 635 Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Matt Michels Address: 27-60 Yennecott Dr Southold Cross Street: Boisseau Ave Phone No.: 631-767-6034 Bldg.Permit#: 46164 email:mjmichel83@gmaii.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Finished Basement Square Footage: 125 Circle All That Apply: Is job ready for inspection?: ❑ YES ✓V NO ❑✓ Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑� NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 D H Frame Pole Work done on Service? Y , N Additional Information: PAYMENT DUE WITH APPLICATION CP .rL ew�in �runn-p s wr� ; D GENERAL NOTES: • The information on this set of construction documents Miche1 ' 5RC5 1 e n ce is to relate basic design z O � p intent and framing details. They are intended as a construction aid, not as a substitute for generally accepted good budding practice and are in compliance with current 2020 New York State Budding Codes and the 2018 IRC. The general contractor � z N 15 responsible for providing standard construction details and procedures to ensure a P RO PO5 E D E I N 15 H E D BASEMENT FIRST FLOOR AREA Q m z professionally finished, structurally sound and weatherproof completed product.' RETAIN STORM WATER RUNOFF • General contractor to coordinate all subcontractors, scheduling of work and 4APP, OVED AS NOT-D PURSUANT TO CHAPTER 236 4"X S POSTS W/ 2"X 2" interaction between trades. BALUSTERS CAP RAIL; DATE: B.P.# � OF THE TOWN CODE. COMPOSITE RAILING SYSTEM z • The contractor is re5pon5 ble for ensuring that all work and construction meets / J or exceeds current federal, state and local codes, ordinances and regulations, etc. FEE: These codes are;to be considered as part of the specifications for this budding plan. NOTIFY B ILDiNG� _='!;RT L T AT ° p p • If in the course of construction, a condition exists which disc rees with that as m FLOOR STRUCTURE g 765-1802 8 AM 10 - �P:,i FOR THE indicated on these drawings, the contractor Shall stop work and notify the designer FOLLOWING INSPECTIONS: it the engineer Immediately. Should he fail to follow this procedure and continue work, he shall assume all responsibility and liability arising therefrom. 1. FOUNDATION - T IO REQUIRED GRADE Dimensions take precedent over scale-DO NOT 5CALE DRAWINGS. FOR POURED CONCRETE ELECTRICAL 8" POURED CONCRETE • 2. ROUGH - FRAM,N'�; & PLUMBING FOUNDATION WALL • The designer has not been engaged for construct on supervision and assumes no 3. INSULATION 'iNSPECTION RECUR ED responsibility for construction coordinating with these plans, nor responsibility for o construction means, methods, techniques, sequences or proceedure5 or for safeey 4. FINAL - CON$i RUB r ',� MUST #5 REBAR @ 12" D.C. PROPOSED precautions and programs in connection with the work Indicated. There are no BE COMPLETE J. OUTSIDE #5 REBAR @ 1 2" O.C. ENTRANCE FINISHED BASEMENT warranties for a specrfic use er:pressed or implied In the use of these plans. ALL CONSTRUCTI�i :: iALL MEET THE (VERTICALLY) • Contractor to provide hardwired smoke detectors, with battery back up, and with REQUIREMENTS OF THE CODES OF NEW no Intervening switches, on all floors and in each bedroom. Verify with local code YORK STATE. NOT RESPONSIBLE FOR requirements as per Section R317 New York State Residential Con5truciton Code. DESIGN OR CONSTRUCTION ERRORS. @ 2 O.C. Install carbon monoxide detectors as per code. pr UR .SING #5 REBAR I " FOUNDATION NOTES: ALL PLUMBING WASTE ° &WATER LINES NEED-- , 3'-O"x 8" POURED • General contractor to review plans, elevations and details to determine COMPLY WITH ALL CODES OF TEGTING BEFORE COVERING- CONCRETE FOOTING intended heights of finished floor above typical grade. NEW YORK STATE & TOWN CODES ON COMPACTED FILL L • Footings shall bear on undisturbed sod within bearing capacity of 1.5 ton5/5q.ft. AS REQUIRED AND CONDITIONS OF 5TAI R WALL DETAIL � • Concrete shall be FC = 3,500 PSI @ 28 days PLUA! SER CERTiFICAT/0/,' 4" CONCRETE SLAB 44'-0" PITCHED TO CENTER FOR SCALE: = I -0 • Concrete on 4"sand or gravel fill minimum, with GxG- 10/10 welded wire mesh ON LEAD CONTENT BEFOr 4 N to reinforcement. Interior slabs to be placed on G mil. stabilized polyethylene vapor ARD � 3 bar u o is to assure that the reinforcement 1,iv_U II JRUST ra J CERTIFICATE OF / DRAINAGE — barrier. Welded wire mesh is to be placed in the top third of the slab and is to be OCCUPAw 23'-e, ! - ------- s � Z CO adequately supported by precast concretea s pp Y� y GES E 18T,NG BILCP- }- ' is held in position during concrete placement and finishing. SOLDER USED IN WATER WALL E �fRl'T8-BE o ILn — N, �� SUPPLYSYSTEMCANNOT R MCVED 4, U � o • Isolation joints are to be installed between the slab and the walls. Use reformed FIBERGLASS DRYWALL --.r 4 X 4 POSTS W/ 2 X 2 c6 O J p EXCEED 2110 OF 1% L EA D. - -- - R o Joint filler that Is to be cut 112"'below the slab surface and the re5u(ting Joint is to be filled ° � W/STt=FL R.F!NFORCING; � ! BALUSTERS * CAP RAIL; � N � _ with an ela5tomericjoint sealant. ANDERSEN 400 SERIES PROVIDE 4" P.C. 5LA8, USE COMPOSITE CASEMENT WINDOW; PiTCHED WITH DRAIN RAILING SYSTEM • General contractor to install cop-r-tex(or copper) sheet metal termite shields BOTTOM SILL NOT TO CX145 between all wood surfaces that are exposed to concrete or masonry surfaces. EXCEED 44" ABOVE — • Dam roof exterior of foundation wail with a bituminous coatin Foundation OCCUPANCY OR FINISHED FLOOR ---- — NEW POURED CONCRETE pp g' 'EGRESS AS PER CODE s'-5 u2" -- ENTRY STAIRS excavation upon approval of building department inspections. F' USE IS UNLAWFUL Blower dooB UP NUMBER OF TKEDS TO LU PLUMBING * HVAC NOTES: WITHOUT CERTIFICATE and duct`vorl; BE VERIFIED IN FIELD BASED • All plumbing work shall be done by a duly licensed plumber and must conform and adhere I _ CX 145 116 2 �r j _ ON EXISTING GRADE � `W to all New York State building codes*safety requirements. OF OCCUPANCY testing;required. I _� - -- 3068 f J 9 plumbing ci P EXISTING - --- - --- . 0 • If wall lates or gists are cut during the installation of lumbin fixtures ore ui merit I� � � contractor must provide appropriate bracing to tie framing back together. EGRESS �)Nlf bop,PLACEMENT 3'-6° — 3'-10"+/-— O TO E INSTALLED TIGHT � � g pp Y y P SWLj_ ___ _-._ _ TO T 5 SIDE OF —� PROV. EPDXIED #4 STEEL _ CLOSET 2 G8 UTILITY DOOR w/ 10.o,�---- - �— -- - -—!3'-10^- - 13'-7° - i� • Plumbin fixtures to be su lied b owner, installed b lumber. I EXIST NG BILCO DOOR REBAR HORIZONTAL @ 1 2 O.C. (n • Mechanical subcontractor is responsible for adhering to all applicable codes and III INTO FOUNDATION WALL* ALL Z safety requirements. 1) AREAS OF ABUTTING WALLS • HVAC subcontractor to fully coordinate system data 4- requirements with the I WITH FOOTINGS equipment supplier and to pro ride final system layout drawing and submit it to general contractor, 4`} - — EXISTING FIRST FLOOR STRUCTURE owner and equipment supplier For final review 4 approval. BEDROOM TO REMAIN, ALL AREAS ELECTRICAL NOTES: NI 170 50 F? 4 S.D. 5.2%LIGHT • All electrical work to be BOARD OF FIRE UNDERWRITERS approved and to include 5.0%VENT installation of fixtures if specifications as Indicated on plans. Light fixtures to be supplied by -- owner and installed by contractor. GFI outlets required at bathrooms and exterior areas. Install STORAGE SHELVING all outlets as per code. All work is to be done in strict accordance with the New York State Code UNDER STAIRS 2 8 2� WALL LEGEND: by a licensed electrician. All new switches* outlets to be Leviton, Toggle, supplied *installed II ( STORAGE, GYM AREA, 0 by contractor. Contractor to do all hook-ups as requiredbathroom fans,for bathroo fans, cooking exhausts and I MECHANICALS provide wiring as required for gas fireplace and cooking appliances. C.O. OUTLINE OF EXISTING AREAS TO BE REMOVED FRAMING NOTES: N 45.D. 20G8 20&5 c.o. Ir I EXISTING WALLS TO REMAIN • All lumber 15 to be Douglas Fir#2 or better at I G"on center <5 0. b'-10 3/4" 4'-7 3/4" Ln • All wood framing in contact with concrete or masonry is to be pressure treated. 'ACC'designation refers to current arsenic-free treated wood standards and shall take the place of'CCA' - 8" POURED CONCRETE FOUNDATION WALL W/#4 �r UNEXCAVATED- BATH CLOSET N PROVIDE PIT WITHIN REBAR @ 12" OC BOTH DIRECTIONS; KEYWAY • All TJI'5 are to be installed in accordance with the manufacturer's 5peclfication5 and shall include GARAGE ABOVE - 30"X 8" FOOTING; PROVIDE 3- #4 REBAR WITHIN LLB `n squash blocking web stiffener at bearing points on girders and other load bearing areas o = BASEMENT SLAB FOR EXISTING FIRST FLOOP,STRUCTU E FOOTING. FOOTINGS TO ALIGN w/EXISTING DEPTH; LU � EJECTOR PUMP lL1 l etc. are to be galvanized. Desi Hated connectors straps, TO REMAIN, ALL AREAS I -- HEIGHT OF WALL TO BE 8" ABOVE GRADE N o All straps, connectors plates, bolts, nails,p , p 9 9 p N } are o be i are b Simpson unless otherwise indicated. All connectors, straps, etc e t etc. on these drawings a y y p p I � �, naded/bo!ted in accordance with the manufacturer's specifications. 2x4 STUD FRAME PERIMETER WALLS @ 16 OC. Q MASONRY FIREPLACE PROVIDE R-1 5 INSULATION #Z" DRYWALL TO FINISHED • All floor sheathing Is to be 4"AC type plywood, tongue FOOTING TO REMAIN groove and Shall be glued and screwed to UP TO ______— SIDE; INSTALL z' FOAM BOARD INSULATION AGAINST the floor Joists(G"o.c. edges 12"o.c. field) FIR5T FLOOR AS EXISTING FOUNDATION WALLS PRIOR TO FRAMING. (� Id • Solid blocking i5 to be installed every 8'-0"max. or mid span of all floor Joists with spans exceeding -- TRIM 8'-0". Blockingis to be installed at all point load bearing points. u 0 z TRIMMED 2x4 STUD FRAME PARTITIONS, WITH z" DRYWALL p g p I, 32 8 OPENING III I UTILITY TiON EACH SIDE OF FRAMING. EXISTING RAISED HEARTH • Install double Joists under all partitions running parallel OPItNING � O CLOSET 2x4 STUD FRAME PARTITIONS COMMON TO UNFINISHED • All exterior wall headers to be as indicated on floor plans*sections and all interior — BASEMENT AREAS; PROVIDE R-15 INSULATION WITHIN WALLS headers are to be 2- 2"x 8" Lnless otherwise noted. All headers exceeding 5'-0"shall have a double z" DRYWALL TO FINISHED SIDE OF FRAME. Jack stud with a single king stud t on exterior walls provide double sill plate (typical). J I I - ------------------ 23'-7 1/2" UNEXCAVATED- FRAMING NOTES: PORCH ABOVE R-15 BATT IN WALL • USE ACQ STUDS FOR ON ALL AREAS FRAMED COMMON TO ANY AGAINST CONCRETE. EXISTING BASEMENTIII UNFINISHED AREA INTERIOR DOORS �TRIMMED OPENINGS TO a PROPOSED FINISHED SPACES ... AS SHOWN RECEIVE 2- 2x8 HEADERS UNLESS OTHERWISE NOTED. 7-1 O" HEIGHT TO UNDERSIDE OF JOISTS EGRESS WINDOW t EXTERIOR DOOR TO HAVE 4"0 RooF VENT MINIMUM 3- 2x8 ACQ HEADER. ROOF LJ EXISTING 3- 2x 10 DRO IPED • ALL BASEMENT WINDOWS ARE EXISTING f-TO LLJ GIRDER TO REMAIN, AL AREAS. REMAIN; PROVIDE EXTENSION JAMB5 AS NEEDED TO z r 4 FAMILY ROOM EXISTING COLUMNS AL TO REMAIN; FINISH SPACE. UI ATTIC WRAP FINISH ANY EXPC 51 m o COLUMN • PROVIDE R-19 BATT INSULATION TO UNDER W ______ -------- ------ SIDE OF EXISTING FIRST FLOOR SUBFLOOR ---- BAT11 2 m KITCH N ------ BA H I --- --- - - - - LAUNDRY --- - - EXISTING 311 TO REMAINALL AREA00 SSTRUCTURE CEILING TO BE 2' DRYWALL-OR- DROPPED CEILING p[ GRID w/TILES TO COMPLETE SPACE. W �1 112 I p1 112 1 112 1 1/4 I � oN 0 i11/4 1/4 1114 $11/2 • PROVIDE MECHANICAL VENTILATION SYSTEM� ' LIGHTING IN ACCORDANCE w/ NYS RESIDENTIAL CO DEINK °I ° o3 z p W'M I WITHIN ANY AREA LACKING SUFFICIENT, OPERABLE WINDOWS. �- o ° SHdWER i U FIRST FLOOR L-- Q N 2 „ra s PLAN NOTES: 2 2 3 2 4"C.I.l z O I�---- HOUSE • EXISTING ONE STORY RE5IDENCE w/3 BEDROOMS; TRAP TO EXISTING SCDHS BATH 3 - APPROVED 5EPTIC SYSTEM PROPOSED 4th BEDROOM IN BASEMENT. 4 • EXISTING SEPTIC SYSTEM, AS APPROVED BY 5CDH5 - ---- --- NEW -- ---- _._ DOOR wi III 3 20G8 SWEEP CON515TING OF (2) 600gal. SEPTIC TANKS EACH CONNECTING TO AN 8'-0"0 x 8'-0" PRECAST POOL, TO REMAIN AS 11" �1}" W CLOSET �UTILITY SUFFICIENT AND IN GOOD WORKING ORDER. ... 24'-GIII _ HCWE EXISTING EXISTING LOWER LEVEL 2 ----- 30'-0-- 1E OF 5 PROPOSED PA5EMENT LAYOUT PSJRf SLOPE" I/4" PER FOOT PITCH TO SCALE: PAGE. ^ii = I '-O° .� r �� `� t DRAIN i PLUMBING R15ER DIAGRAM N� 5741 NO SCALE L S101AN UNAUTH091ZED ALTERATION OR ADDITION TO TH15 DRAWING AND RELATED DOCUMENT5 45 A VIOLATION OF5EC. 7209 OF THE IV.Y.5. EDUCATION LAW