Loading...
HomeMy WebLinkAbout48924-Z �o�S�FF01�-�0 Town of Southold 3/25/2024 a G� -; P.O.Box 1179 0 o _ 53095 Main Rd Southold,New York 11971 r ' CERTIFICATE OF OCCUPANCY - No: 45072 Date: 3/25/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2750 Nassau Point Rd, Cutchogue SCTM#: 473889 Sec/Block/Lot: 104.-12-16 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/3/2023 pursuant to which Building Permit No. 48924 dated 2/16/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Monaghan,Kenneth of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 48924 7/24/2023 PLUMBERS CERTIFICATION DATED Aut r e gnature UFFe4�,co TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE "o • SOUTHOLD, NY . BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48924 Date: 2/16/2023 Permission is hereby granted to: Monaghan, Kenneth 2 Greenside Ct Durham, NC 27707 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 2760 Nassau Point Rd, Cutchogue SCTM #473889 Sec/Block/Lot# 104.-12-16 Pursuant to application dated 2/3/2023 and approved by the Building Inspector. To expire on 811712024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector pF SO!/r�Ql 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 Q sean.deviin(aD-town.southold.ny.us Southold,NY 11971-0959 Q �yC4UNT`1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Kenneth Monaghan Address: 2750 Nassau Pt Rd city:Cutchogue st: NY zip: 11935 Building Permit* 48924 Section: 104 Block: 12 Lot: 16 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: GreenLogic LLC License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 10.15kW Roof mounted PV Solar Energy System w/ (29) 350W Modules, AC Disconnect, Combiner Panel, Monitor Notes: Solar Inspector Signature: Date: July 24, 2023 S.Devlin-Cent Electrical Compliance Form SOUTyo # TOWN OF SOUTHOLD BUILDING DEPT. `ycou 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ 'FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE �•a�'�5� INSPECTOR OF SOUIyo<o f # TOWN OF SOUTHOLD BUILDING DEPT. Comm 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] `PRE C/O [ ]- RENTAL REMARKS: J"i -2-e- 4A CPA J J DATE -7 2-0 INSPECTOR ` ho�aof SOUIyO� L_I L� 2,�-j / c, O J * # TOWN OF SOUTHOLD BUILDING DEPT. u 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE &.CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ]cPRE C/O [ ] RENTAL REMARKS: cN � cc — Ok DATE 2, q INSPECTOR Pacifico Engineering PC i Engineering Consultin 700 Lakeland Ave, Suite 2B - Ph:631-988-000 Bohemia, NY 11716 GC solar@pacificoe ineering.col December 8 2023 � ` � J IL i _e J Town of Southold , Building Department - ' ' F E B 5 2024 54375 Route 25, P.O. Box 1179 Southold, NY 11971 ; v„ n ._ '_ Subject: Solar Energy Installation for Kenneth Monaghan 2750 Nassau Point Road Permit Number: 48924 Cutchogue, NY 11935 1 have reviewed the solar energy system installation at the subject address on December 8,2023.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installatioi meets the requirements of the 2020 Residential Code of New York State and ASCE 7-16. To my best belief and knowledge,the work in this document is accurate,conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer of Nriyy` � PACi�,�®�� r` RaIP er :;� s�IVY06 'IELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) y -41 FOUNDATION (2ND) z 0 a � ROUGH FRAMING& ,�� PLUMBING j 0 . S INSULATION PER N.Y. STATE ENERGY CODE 3,ao. ak •�• _ � _ FINAL ADDITIONAL COMMENTS ' rtelc 0--b 11) 'g-ink3 0,10 t I c- , -o 4 % o Z 0�4 m � 0 z y x H TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 hqps://www.southoldtonM.gov Date Received APPLICATION FOR BUILDING PERMIT ,For office use Only PERMIT NO. q; - Building Inspector: FEB 0 3 2023 ffitist be filled 6,'�t` h kpplicali'oni�an fdem!;' int eirentirft1qqqmppteapplications virilF , QUEPT not be arcepted',"Whe"ie th eo'wn­q'rj:an­' BUMIN gApplicant is Kot th diwiiier's46ilibrizkiortlorm{page 2)shall'be completed. Date: 1/24/2023 OWNERS)-OF,PilqpkRTY Name: Kenneth Monaghan S C T M#100 0 104-1 2-16 .......... Project Address: 2750 Nassau Point Road, Cutchogue, NY LD Phone#: Email: ---------- Mailing Address: 2 Greenside Court, Durham, NC 27707 .................................................................................... ................. .................................................. . . ....... .......... .............. ...................... ........ ........... ............. ............. CONTACTPER.ON: , Name:Barbara - GreenLoaic LLC Mailing Address:97 North Sea Road, Southampton, NY 11968 Phone#:631-771-5152 x117 Email:BarbgLq@greqrllogic.com----,-------- :�DtSJG Nj PROFESSIONAL INFORMATION:; Name: Pacifico Engineering PC Mailing Address: 700 Lakeland Avenue, Suite 2B, Bohemia, NY 11716 Phone Email: solar,@P q(T1qqeqgiPPer!R9.-CoT1­....... M o�-WNTgAddklR' Name:GreenLogic LLQ ............... Mailing Address:97 North Sea Road, Southampton, NY_ 11968 Phone#:631-771-5152 Email:AMOGreenlo_gjc.I go mbb DtsCkiP-TION-,OF:PROPOSED"CONSTRUCTION E]NewStructure ElAddition RAlteration E]Repair E]Demolition Estimated Cost of Project: 9 Other Solar Panels $ 39,000 Will the lot be re-graded? []Yes [i]No Will excess fill be removed from premises? E]Yes NINo PROPERTY INFORMATION Existing use of property: S i �h, P Intended use of property: Zone or use district in which premises.is situated:, Are there any covenants and restrictions with.respect to this property? ❑Yes $No IF YES,.PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professlonal is responsible for all drainage and storm water Issues as provided,by. Chapter236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section,210AS of the New York State Penal Law. Application Submitted By(print name):GreeIILOgIC LLC [@Authorized Agent .❑Owner Signature of Applicant: Date: r 12- 3 STATE OF NEW,YORK) SS: COUNTY OF Suffolk NeSim AlbUkrek being duly sworn,deposes and says that (s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and-is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of-his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this C day of&LU01 20 a Notary Public BARBARA A CASCIOTTA Notary PLIM State of New York No.01-CA4894969 PROPERTY OWNER AUTHORIZATION Qualified In Suffolk County (Where the applicant is not the owner) Commission Expires May 9f.2023 KcL­4 �tu,. residing at ZZ'SD �c�sc�k ll'b:�..�JC4t do.hereby authorize GreenLOgIC LLC to apply on my beh if to t own o Southold Building Department for approval as described herein. Owner's Sign ture r Date Print Owner's Name 2 F 1 F Ft . BUILDING DEPARTMENT- Electrical Inspector S3. TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCa)southoldtownny.gov — seand(a-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/24/2023 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com ' Phone No: 631-771-5152 [gkrequest an email copy of Certificate of Compliance Address.: , 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Kenneth Monaghan Address: 2750 Nassau Point Road Cutcho ue NY Cross Street: Phone No.: 631-298-7900 Trish (North Fork Woodworks) Bldg.Permit#: email: estimates@nfwoodworks.com Tax Map District: 1000 Section: 104 Block: 12 Lot: 16 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (24) SunPower SPR-M415-H-AC panels Et (24) Enphase IQ7H icro inverters (1) SunPower PVS6 monitor System Size: 9.960KW - C - Check All That Apply: 1 d' SkW Is job ready for inspection?: ❑YES ENO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: EYES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 02 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information. PAYMENT DUE WITH APPLICATION �Uv 'I Electrical Inspection Form 2020.xlsx \ �I CERTIFIED TO.KENNETHMO.NAGHAN LOT AREA:37,127SO.FT=0852ACRE SURVEY OF MEHEREON REFER TO NAVD 1988 METES 8 BOUNDS HEREON AS PER ADJOWG DEEDS AND LOT 17 FIELD MONUMENTATION NEAP OF JOB NO.:2019-246 �F NE. ROAD LINFALONG NASSAU POINT ROAD IS AN UNDEFINED CURVE AMENDED MAP'A" MAP:A GU SF W} THE TIE LINE THROUGH THE UNDEFINED CURVE AS PER ADJOINING DEEDS F1LED:Aucusir6,rsz2 �p E+ w Ni oy NASSAU POINT REVISIONS' EQ d ADD TEST HOLE,LOC.UAi MARK OUT * ,� 1 9 ,�, LOT AREA 74 TIE LINE SI TUA TE A T PIOT PROPOSED ADOTIONS All PROPERTIES WITHIN 150'OF SUBJECT BOUNDARYARE NA SSA U POINT ADD NOTES FOR SCDHSAPPLIC. p 1MPRVEDANO SERVICED BY PUBLIC WATER TOWN OF SOUTHOLD FOR ENGINEER r0l9/2020 8 i2/92020 SUFFOLK COUNTY,NEW YORK ADD ENGINEER SAN,DESIGN LOC MI 050538 O� CURRENT ZONING:k-40 S_C._TM.DIST:1000 SEC-,104 BLK. 12 LOT 16 _ F ALLOWABLE LOT COVERAGE 7,425 SQ.FT=20%(BUILDING d ROOFED STRUCTURES) -f6LAND EXISTING LOT COVERAGE 1,256SQ.FT=3.4% 20 10 0 20 40 60 80 100 120 140 160 180 PROPOSED ADDITIONAL LOT COVERAGE:1,116 SQ.FT. SCALE:1'=40' DATE:JANUARY 2.,2019 JEFFREY W.HADERER L.S. PROPOSED LOT COVERAGE 2,372 SO FT.=6.4% LICENSE NO,:050538 ---- --� PROPOSED 2'X 8'-6'BA Y WINDOW ■PROPOSED 10'X tt'1 STORYADDITION 1 PROPOSED 4'X 8`-6-STEPS TUN'Fogg i PROPOSED rx2o-s DECK LAND SURVEYING I t Z ;�;F a TO lL4AWOVJ;tpltrM xumv.U4APLc I PROPOSED 2ndS70RYADDITION LSS W MOWT414:111611W41;UNIT E3 OVER EXISTING PORCH 16'X 20'-6- S� lbtWIONA4M NEW YORK 1194t; 0)631-3698{12-n)6713Fv-83t3 PROPOSED CELLAR ENTRANCE LOT 116 1 t rneatl mintoristuurswvra taAlx,ov; .,PROPOSED 2 STORY ORMERLY Of z v iAW ME wro SURVE ORMAP. POWD$EAL W EMo o s�SHALL No Of t8'-t0'X 39 AODtTION �RD NOw.Mp,N G04�" �,,�•-^�^""� CON5WERED TO BE AVALID COPY AND SHALL NOT BE USED FOR ANY PURPOSt StOn,- ZEST HOLE DAra EL''12.0' 1 W E 14 0 m, V SANDYLOAM p N I _ nC Q W7GRAYEL �' 1? zm �✓T MIXED SAND /''� W/GRAVEL - �( COARSE SAND tsP) Is, 12.0'G.WEL:0.0XbJs /7 a. - 1 =� Y . IsaM.' _..- WATERT 175 '�r RAVEL om COARSE SAND �� aW ( ° i yL4WIG :401- -^_ I 1 (SP) -18.0' O - TESrrWtE ErtCENrti+fEREO+r sELarrs+,eWAcr caADE p ! ...--. Wr'.,,- RLY Of i'S"783E� '~ 1 LOT74 .% a - NDNOy/OR�a ESLYOF LA MAURV N may... ------Tb-_----. _E)D'ST1NG CONTOUR DIGITAL RELEASE � - PROPOSED coNr4uR �� GREENLOGIC" ENERGY January 30, 2023 Town of Southold Building Department Town Hall F 53095 Route 25 Southold, NY 11971 Project Info: Kenneth Monaghan 2750 Nassau Point Road Cutchogue, NY 1000-104-12-16 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, xwdtww emcivtta Barbara Casciotta Account Manager Barbara@Greenlogic.com GREENL� iC� � �er�l ic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 DATE(MM/DDIYYYY) CERTIFICATE OF LIABILITY INSURANCE 01I2612023 ,4 n CONFERS NO RIGHTS UPON THE THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, AUTHORIZED BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. ro IMPORTANT: If the certificate subject eet to theD elnns and condNAL iRonstof the policy,Bert in polic esmayNequiNe an endorselment. A stat merit on If SUBROGATION IS WAIVED, ) this certificate does not confer rights to the certificate holder in lieu of such aCONTA dor a bolas Zulkofske PRODUCER PHOIr NE 631 941-4113 FAX 631 941-4405 Brookhaven Agency,Inc. E-MAIL Certificates@ brooknavena enc .com 100 Oakland Ave,Ste 1 NAIC# INSURERS AFFORDING COVERAGE Port Jefferson,NY 11777 INSURER A. Southwest Marine&General insurance o. INSURER B-Merchants Preferred Insurance Co. INSURED GreenLogic,LLC INSURER c:First Rehab Life Insurance o. J 97 North Sea Rd,Suite 3 IN56RERD:National Liabifi &Fire Insurance Co. Southampton NY 11968 INSURERE: AGCS Marine Insurance Co. INSURER F ' REVISION NUMBER: OD COVERAGES CERTIFICATE NUMBER: ICY THIS IS TO CERT ITTHAI HSTA N NG ANYEREQUIREMNT,TERM OR CONDLISTED ITION ON OF ANY CONTRACOT OR OTHER DOCUMENT WITH RESP CT THE INSU T OLWHICHTIHIS INDICATED. NO CERTIFICATE MAY ND BE ISSUED OF MAY PERTAIN,THE I LIMITS SHNCE AFFORDED OWN MAY HAVEBBEEN REDUCED BY PAID CLAIMS.BED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS A POLICY EFF MpOL0CY EXP LIMITS INSR ADDL SUB POLICY NUMBER TYPE OF INSURANCE EACH OCCURRENCE $1,000,000 X COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED $100 000 A CLAIMS-MADE J OCCUR 01/3112023 01f31I2024 MED EXP An one erson $5 000 X Contractual Liability X X GL202300012922 PERSONAL&ADV INJURY $1 000 000 GENERAL AGGREGATE $2,000 000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $2 000 000 POLICY JECOT 0 LOC E&O Liabilit $1,000 000 COMBINED SINGLE LIMIT - $1 000 000 OTHER: AUTOMOBILE LIABILITY 'BODILY INJURY(Per person) $ B X ANY AUTO 08111/2022 0811112023 BODILY INJURY(Per accident) $ OWNED SCHEDULED X AUTOS ONLY AUTOS HIRED NON-OWNED $ X AUTOS ONLY X AUTOS ONLY i EACH OCCURRENCE $ UMBRELLA LIAR OCCUR AGGREGATE $ EXCESS LIAR CLAIMS-MADE $ DED RETENTION$ PER OTH- WORKERS COMPENSATION AND EMPLOYERS'LIABILITY E.L.EACH ACCIDENT $ Y ANY PROPRIETORIPARTNER/EXECUTIVE❑ NIA see separate certificate E.L.DISEASE-EA EMPLOYEE.$ OFFICERJMEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-POLICY LIMIT $ I(yes,describe under DESCRIPTION OF OPERATIONS below D251202 04/1112022 04/11/2023 Statutory Limits C NYS Disability 04/1512022 0411512023 $300,000 $2,500 Ded E Installation Floater/Property SML93076366 chedule,may he attached if more space is required) DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks S Certificate holder is also named as Additional Insured. CANCELLATION CERTIFICATE HOLDER SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE TOWN OF SOUTHOLD THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. i <NSZ> 53096 ROUTE 26, SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE I ©1988-2015 ACORD CORPORATION. All rights reserved. I The ACORD name and logo are registered marks of ACORD ACORD 25(2016/03) 1 J YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Greenlogic LLC (631)771-5152 97 North Sea Rd Suite 3 1c.NYS Unemployment Insurance Employer Registration Number of South Hampton, NY 11968 Insured Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) United Wisconsin Insurance Company 3b.Policy Number of Entity Listed in Box"1 a" TOWN OF SOUTHOLD WC605-00090-023-SZ BUILDING DEPARTMENT 53095 ROUTE 25 3c.Policy effective period SOUTHOLD,NY 11971 01/01/2023 to 01/01/2024 3d.The Proprietor,Partners or Executive Officers are Included.(Only check box if all partners/officers included) EJ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers' Compensation Law.(To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Alicia Christiansen (Print name of authorized representative or licensed agen•o'in--•rance carrier) Approved by: (Signature) (Date) Title: Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 941-306-3077 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov J YORK workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carree la.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured GREENLOGIC,LLC 631-941-4113 97 NORTH SEA ROAD,SUITE 3 SOUTHAMPTON,NY 11968 1c.Federal Employer Identification Number of Insured Work Location of Insured (Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e., Wrap-Up Policy) 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD BUILDING DEPARTMENT 3b.Policy Number of Entity Listed in Box"1a" 53095 ROUTE 25 DBL251202 SOUTHOLD, NY 11971 3c.Policy effective period 04/11/2021 to 04/10/2023 4. Policy provides the following benefits: FvJ A.Both disability and paid family leave benefits. B.Disability benefits only. C. Paid family leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 4/7/2022 By AW/ hf (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board (Only if Box 4B,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 111111111 1°°°1°°°°1°1°1°1°°1°°°°°�IIIIIII DB 120.1 (12-21) NV tv 'v". '7, 1 10", 6 SUM& County Executive's 0 ce of Consumer Affairs ffi ...... ..... VETERANS MEMORIAL FUGHWAY HAUPPAUGE,NEWYORK 11788 u .......... DATE ISSUED: 5/25/2006 •No. 40227-H 7. W ffl3 N ............ SUFFOLK COUNTY Home Improvement Contractor License 40 i This is to certifv that MARC A CLEAN doing business as ........ GREEN LOGIC LLC having ftunished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the Count'y of Suffolk, State of New York is hereby licensed to conduct business as a HOME '5 IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Bgsinesses NOT VALID WITHOUT D)TARTMENTAL SEAL AND A CUR"NT CONSUNJER AFFAIRS ID CARD Director J0 �YI Vp --a- �i f.6 t- Al".-A J. .4 t Ab- Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 DATE ISSUED: 12/10/2007 No. 43858-ME SUFFOLK COUNTY M .Master .Electrician License � This is to certify that ROBERT J SKYPALA doing business as GREENLOGIC LLC having given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York. k Additional Businesses NOT VALID WITHOUT DEPARTMENTAL SEAL AND A'CURRENT CONSUMER AFFAIRS Iln CARD ` C - a ®! Director J Am �� DATE( CERTIFICATE OF LIABILITY INSURANCE Fol/261202MMIDDNYYY)3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Nicholas Zulkofske Brookhaven Agency,Inc. PHONE 631 941-4113 Fax 631 941-4405 100 Oakland Ave,Ste 1 E" Lss, Certificates@ brookhavena enc .com Port Jefferson,NY 11777 INSURERS AFFORDING COVERAGE NAIL# INSURER A: Southwest Marine&General Insurance Co. INSURED INSURER B:Merchants Preferred Insurance Co. GreenLogic,LLC INSURERc: First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURERD. National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E. AGCS Marine Insurance Co. INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADOL SUER POLICY NUMBER POLICY EFF POLICY EXP LIMBS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1 00O 000 A CLAIMS-MADE lil OCCUR DAMAGE TO RENTED $10O 000 X Contractual Liability X X OL202300012922 01/31/2023 01/31/2024 MED EXP(Any oneperson) $5 000 PERSONAL&ADV INJURY $1 000 000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2 00O 000 POLICY®JECT 7 LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: E&O Liability $1 000 000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1 000 000 B X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08/11/2022 08/11/2023 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per arrident) $ UMBRELLA LIAB HOCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N ANY OFFICERIMEM ER EXCLUDED?ECUTIVE❑ N/A see separate certificate E.L.EACH ACCIDENT $ (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ C NYS Disability D251202 04/11/2022 04/11/2023 Statutory Limits E Installation Floater/Property SML93076366 04/15/2022 04/1512023 $300,000 $2,500 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <NSZ> @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD 1O1"EWorkers' E Compensation CERTIFICATE OF Board NYS WORKERS COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Greenlogic LLC (631)771-5152 97 North Sea Rd 1 c.NYS Unemployment Insurance Employer Registration Number of Suite 3 South Hampton,NY 11968 Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) United Wisconsin Insurance Company 3b.Policy Number of Entity Listed in Box"1a" TOWN OF SOUTHOLD WC605-00090-023-SZ BUILDING DEPARTMENT 53095 ROUTE 25 3c.Policy effective period SOUTHOLD,NY 11971 01/01/2023 to 01/01/2024 3d.The Proprietor,Partners or Executive Officers are ❑ included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Alicia Christiansen (Print name of authorized representative or licensed agen'o`in -rance carrier) Approved by: 49�_ . w31e9lGl'li i' .Z� (Signature) (Date) Title: Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 941-306-3077 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov Y� workers' CERTIFICATE OF INSURANCE COVERAGE STATE .COmpenSatidR Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured GREENLOGIC,LLC 631-941-4113 97 NORTH SEA ROAD,SUITE 3 SOUTHAMPTON,NY 11968 1 c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD BUILDING DEPARTMENT 3b.Policy Number of Entity Listed in Box"I a" 53095 ROUTE 25 DBL251202 SOUTHOLD, NY 11971 3c.Policy effective period 04/11/2021 to 04/10/2023 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: 0 A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 4/7/2022 By AW 4l(/ (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board (only if Box 413,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 1111111111°°1°°°°1°°11°1°°1°°°°1°IIIIIII sy. Suffolk County Executive"s 0 ce of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEW YORK 11788 DATE ISSUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY Home Improvement Contractor License This is to certifv that MARC A CLEAN doing business as GREEN LOGIC LLC having ftumished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME W. MROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses Nf NOT VALID WITHOUT D)EPARTMENTAL SEAL R. AND A CURRENT CONSUNAElt AFFAIRS ID CARD Director F �v AP R VED AS NOT&- � DATE: B.P.# 6 �� ELECTRICAL FEE: BY: INSPECTION REQUIRED NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING•INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTF". C, 10N MUST BE COMPLETE ;-Jp, 5.0. ALL CONSTRUCT'.:N SH TALL MEET THE REQUIREMENTS OF THE CODES OF NEW �n / YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF ( � rea- NEW YORK STATE & TOWN CODES f AS REQUIRED AND CONDITIONS OF Cni ITLIr11!1 TniAitii 7Dh V l u I V 1111 L U!1� q TOWN-PtA-NNING BOARD r u--P TRUSTEES 1.J,IY' ,J�l.,• JCCUPANCY OR USE IS UNLAWFUL WITHOUT-CERTIFICAT OF OCCUPANCY r 6acifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2B C Ph:631-988-0000 Bohemia, NY 11716 IG solar@pacificoengineering.com January 31,2023 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Kenneth Monaghan 2750 Nassau Point Road Cutchogue, NY 11935 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. Roof Section A B C D Mean roof height 16.0 ft 22.0 ft 16.0 ft 22.0 ft Pitch 17 degrees 30 degrees 50 degrees 36 degrees Roof rafter 2x10 2x8 2x10 2x10 Rafter spacing 16 inch on center 16 inch on center 16 inch on center 16 inch on center Reflected roof rafter span 13.7 ft 8.6 ft 5.2 ft 7.5 ft Table R802.4.1(1) max allowable 22.5 ft 18.5 ft 22.5 ft 22.5 ft Fastener Type SS 5/16"dia lag bolt, SS 5/16"dia lag bolt, SS 5/16"dia lag bolt, SS 5/16"dia lag bolt, 4-3/4"length 4-3/4"length 4-3/4"length 4-3/4"length Fastener Capability 1067 lb 1067 lb 1067 lb 1067 lb Fastener Spacing,Zone 1 /2/3 64/64/64 in 64/64/64 in 64/64/64 in 64/64/64 in Point Pullout, lb,Zone 1 /2/3 322/451 /692 lb 338/402/402 lb 354/402/402 lb 338/402/402 lb Zone Category 1 /2/3 1 /2/3 1 /2/3 1 /2/3 1 /2/3 Uplift Pressure Zone 1 /2/3 20/28/43 psf 21 /25/25 psf 22/25/25 psf 21 /25/25 psf Exposure Category C Ground Snow Load, Pg 20 psf Wind Speed, 3 sec gust 130 mph O t , array dead load 3.5 psf �Q` Q�% 04G+�� G,p load per attachment 56.3 lb The subject roof has 1 layer of roofing. Panels mounted flush to roof no higher than 6 inches above roof surface. I Ralph Pacifico, PE tP� Professional Engineer Ralph ac 8> -Engineer NY 066182 GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#A: Total System Size:9.960kW Array Size:3.735kW 1 circuit of 9 on a 20A breaker Azimuth:235' Pitch:17' Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:17'2"X 12'41/8" Surface:22'5"X 15'10" Magic#:Invisimount Legend: ® 9 SunPower415W Panels SunPower Invisimount Rail • 17 IronRidge Flash Foot 2 B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: °AC/�c�y�'p 0 � i �R V6Give- Drawn By:MA Drawing#1 of 14 Date:1/23/2023 REV.A Drawing Scale:1/4"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#A: Total System Size:9.960kW Array Size:3.735kW 1 circuit of 9 on a 20A breaker Azimuth:235° Pitch:17' Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-M415-BLK=H-AC Racking:SunPowerinvisimount Panel:73.7"X 40.6" Array:17'2"X 12'41/8" Surface:22'5"X 15'10" Magic#:Invisimount Legend: ® 9 SunPower 415W Panels SunPower Invisimount Rail • 171ronRidge Flash Foot 2 B B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: PAC, y�'A SI�,P� i Drawn By:MA Drawing#2 of 14 Date:1/23/2023 REV:A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#A: Total System Size:9.960kW Array Size:3.735kW 1 circuit of 9 on a 20A breaker Azimuth:235' Pitch: 17' Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC 1 Racking:SunPowerinvisimount Panel:73.7"X 40.6" Array:17'2"X 12'41/8" Surface:22'5"X 15'10" Magic#:Invisimount Legend: ® 9 SunPower415W Panels SunPower Invisimount Rail • 17 IronRidge Flash Foot 2 8 B 2x10"Douglas Fir Rafter 16"O.C. 1 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: Orr INEPP PP�QN PAC, y0 r 1 � �FESSI® Drawn By:MA Drawing#3 of 14 Date:1/23/2023 REV:A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#B: Total System Size:9.960kW Array Size:1.660kW 1 circuit of 4 on a 20A breaker Azimuth:145' Pitch:30' Monitoring System: SunPower 0— Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPowerinvisimount Panel:73.7"X 40.6" Array:13'8 5/8"X 6'1 3/4" Surface:26'5"X 10'8" Magic#:Invisimount Legend: ® 4 SunPower 415W Panels — SunPower I nvisimount Rail • 8 IronRidge Flash Foot 2 8 B W"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: N PAQ yQ� 81 Drawn By:MA Drawing#4 of 14 Date:1/23/2023 REV:A Drawing Scale:1/4"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#B: Total System Size:9.960kW Array Size: 1.660kW 1 circuit of 4 on a 20A breaker Azimuth: 145° Pitch:30° Monitoring System: AO SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPowerinvisimount Panel:73.7"X 40.6" Array:13'8 5/8"X 6'1 3/4" Surface:26'5"X 10'8" Magic#:Invisimount Legend: ® 4 SunPower 415W Panels SunPower Invisimount Rail • 8 IronRidge Flash Foot 2 KI V , W"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: .�rG �iyY �aQ�QN pqC/���' • 9oF�ESSI0NP4 . Drawn By:MA Drawing#5 of 14 Date:1/23/2023 REV:A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#B: Total System Size:9.960kW Array Size: 1.660kW 1 circuit of 4 on a 20A breaker Azimuth:145° Pitch:30° Monitoring System: SunPower 0— Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:13'8 5/8"X 6'1 3/4" Surface:26'5"X 10'8" Magic#.Invisimount 2 Legend: ® 4 SunPower 415W Panels SunPower Invisimount Rail • 8 IronRidge Flash Foot B 8 W"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: VA PAC& O E 1 i • ' . 9��FSSIONP� Drawn By:MA Drawing#6 of 14 Date:1/23/2023 REV:A Drawing Scale:1/4'=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#C: Total System Size:9.960kW Array Size:2.905kW 1 circuit of 7 on a 20A breaker Azimuth:145' Pitch:50" Monitoring System: SunPower 0— Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPowerinvisimount Panel:73.7"X 40.6" Array:24'3/4'X 6'1 3/4' Surface:25'3"X 9'10" Magic#:Invisimount Legend: ® 7 SunPower415W Panels SunPower Invisimount Rail • 12 IrcnRidge Flash Foot 2 B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: OF NEOP 'qVI PA OFFSSI�� Drawn By:MA Drawing#7 of 14 Date:1/23/2023 REV:A Drawing Scale:1/4"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#C: Total System Size:9.960kW Array Size:2.905kW 1 circuit of 7 on a 20A breaker Azimuth:145° Pitch:50° Monitoring System: SunPower 0— Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:24'3/4"X 6'1 3/4" IN Surface:25'3"X 9'10" Magic#:Invisimount Legend: ® 7 SunPower 415W Panels SunPower Invisimount Rail • 12 IronRidge Flash Foot 2 B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf En ineerr Architect Seal: A PA CO ' w _ tip u6618-� ��C9 - 9��ESSIONP� Drawn By:MA Drawing#8 of 14 Date:1/23/2023 REV:A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#C: Total System Size:9.960kW Array Size:2.905kW 1 circuit of 7 on a 20A breaker Azimuth:145° Pitch:50° Monitoring System: SunPower 0 Pand/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPowerinvisimount Panel:73.7" Array:24'3/4'X 6'1 3/4" Surface:25'3"X 9'10" Magic#.Invisimount Legend: 3 ® 7 SunPower 415W Panels SunPower Invisimount Rail • 12 IronRidge Flash Foot 2 8 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: OF NEB q%l PAC/��C�O•Q i" Drawn By:MA Drawing#9 of 14 Date:1/23/2023 REV.A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#D: Total System Size:9.960kW Array S ize:1.660kW 1 circuit of 4 on a 20A breaker Azimuth:145° Pitch:36° Monitoring System: 2 SunPower Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:13'8 5/8"X 6'1 3/4' Surface:15'9"X 10'2" Ma is#:Invisimount Legend: ® 4 SunPower 415W Panels x x SunPower Invisimount Rail • 8 IronRidge Flash Foot 2 IZ 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: N PACiri y�� 4 o�FSSiO' P Drawn By:MA Drawing#10 of 14 Date:1/23/2023 REV:A Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#D: Total System Size:9.960kW Array Size: 1.660kW 1 circuit of 4 on a 20A breaker Azimuth:145° Pitch:36' Monitoring System: SunPower 0— Pand/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" Array:13'8 5/8"X 6'1 3/4' Surface:15'9"X 10'2" Magic#: Invisimount Legend: ® 4 SunPower 415W Panels SunPower Invisimount Rail • 8 IronRidge Flash Foot 2 8 8 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4' Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: 0 k,k q'VOA PA 1 9�FESS1®N Drawn By:MA Drawing#11 of 14 Date:1/23/2023 REV.A Drawing Scale: 1/4"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#D: Total System Size:9.960kW Array Size: 1.660kW 1 circuit of 4 on a 20A breaker Azimuth:145° Pitch:36° Monitoring System: SunPower 0— Panel/Array Specifications: Panel:SPR-M415-BLK-H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" A\ Array:13'8 5/8"X 6'1 3/4" Surface: 15'9"X 10'2" Magic#:Invisimount Legend: 4 4 SunPower 415W Panels — SunPower Invisimount Rail • 8 IronRidge Flash Foot 8 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: O Nkppy Q�QN PAC/,e`� 1 � O�FSS10IA Drawn By:MA Drawing#12 of 14 Date: 1/23/2023 REV-A Drawing Scale:1/4'=1.0' No Vent Pipes Will Be Covered By The Solar Array GREENLOGIC® ENERGY Legend: GreenLogic,LLC Approved Monaghan,Kenneth AR-Access Roof AP-Access pathway, 36" minimum width SVO—Setback at ridge 2750 Nassau Point Road per R202 definitions per R324.6.1 as per R324.6.2.1 Cutchogue,NY 11935 Total System Size:9.960kW 1 circuit of 9 on a 20A breaker 1 circuit of 4 on a 20A breaker 1 circuit of 7 on a 20A breaker 1 circuit of 4 on a 20A breaker API IAP I I Azimuth:145° L—svo �/ sve Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-M415-BLK H-AC Racking:SunPower Invisimount Panel:73.7"X 40.6" 4 SunPower Surface:73'X 83'6" 415W Panels ¢ Magic#.Invisimount r----- d Legend: ® 24 SunPower 415W Panels ——— — SunPower Invisimount Rail I • 45 IronRidge Flash Foot 2 10 2x10"Douglas Fir Rafter 16"O.C. on 2x8"Douglas Fir Rafter 16"O.C. Cn Cl Notes: 4 SunPower I Number of Roof Layers:1 415W Panels I Height above Roof Surface:4" Materials Used:IronRidge,SunPower ———a—— Added Roof load of PV System:2.31 psf Engineer/Architect Seal: OF NE* �QN PAC/ �O 9 SunPower IAP �� 415W Panels ————————— IWO Meter 7 SunPower ��FESSI+ON 415W Panels Drawn By:MA Drawing#13 of 14 Date:1/23/2023 REV:A Drawing Scale:1/16"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road JOB MATERIAL LIST Cutchogue,NY 11935 I ( Total System Size:9.960kW ---- 1 circuit of 9 on a 20A breaker 1 ci rcuit of 4 on a 20A breaker 1 circuit of 7 on a 20A breaker —L— 1 circuit of 4 on a 20A breaker i Azimuth:145° Material List gty. Rail Material List tC�y. I Monitoring System: SunPower 0 - -- I Panel/Array Specifications: —Cast Aluminum Mounting Blockw/Black Aluminum Flashing 45 ' Panel:SPR-M415-BLK-H-AC Racking:SunPower ImOsimount 5/16"x0.75"Fender Washer 45 Panel:73.7"X 40.6" -- - — — Surface:73 X 83'6" 5/16"x4.75"Hex-Head Lag Screw 45 Magic#:Invsimount Legend ® 24 SunPower 415W Panels SunPower Invisimount Rail - —--- -- -- • 45 IrcnRidge Flash Foot 2 - ---- ---- 8 2x10"Douglas Fir Rafter 16"O.C. I I 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: arUf-iviEtY y�Q`' 04C 0, S10 �' Drawn By:MA Drawing#14 of 14 Date:1/23/2023 REV.A Drawing Scale:1/16"=1.0' EXITING SERVICE PV—SA-1 AC—COMBINER PANEL 120 240, 1 PH, 3W .................... ° F ffM , FU AC—CMB-1 , • • • ! (PV LOADS ONLY) J 2C}{�A i KW H f PV—SA 2 OA {( r�. . . k N i BKR-1 AC—DSC-1 _ I AC DISCONNECT t i i I BKR-2 t PV—SA-3 k0At N • • . 1 i BKR-3 r MAIN I I J BKR-4 + A B N PV—SA-4 A t I ! FUSED N . . . 2 1 t l N t ! t PC N `�—TYPICAL PV MODULE WITH I t t t t INTEGRAL DC/AC INVERTER t I ! ! EGC EGC I t 9 lttt t t I t I ! EXISTING AC PANEIEXISTING GEC I GEC LIJJ ----- i------------------$--- _____---- --- _ #s cu .� 9.960kW DC 9.216kW AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS o n Monaghan, Kenneth tr.5�tis�. r 2750 Nassau Point Road GREENLOGIC CUP ENERGY Cutchogue, NY 11935 0213� o�� ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Monaghan-3LD1 Revision: 1 Revised: 7/28/22 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-M-415-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 6-MODULES PV-SA-2 PV SUB-ARRAY SPR-M-415-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 6-MODULES PV-SA-3 PV SUB-ARRAY SPR-M-415-H-AC _ ENPHASE IQ7HS, 1-CIRCUIT OF 6-MODULES PV-SA-4 PV SUB-ARRAY SPR-M-415-H-AC ENPHASE IQ7HS, 1-CIRCUIT OF 6-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 2490 WATTS 211-264 VAC 10.13 A AC 240 V,AC PV-SA-2 2490 WATTS 211-264 VAC 10.13 A AC 240 V,AC PV-SA-3 2490 WATTS 211-264 VAC 10.13 A AC 240 V, AC PV-SA-4 2490 WATTS 211-264 VAC 10.13 A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS %AV.D An, ` Monaghan, Kenneth �' sr„ ,fi�� GREENLOGIC 0 2750 Nassau Point Road ENE IRGY Cutchogue, NY 11935 ��� Zi 33 �OQ� ELIMINATING THE 60ST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION of NE`� Page 2 of 3 Drawing No: Monaghan-3LD1 Revision: 1 Revised: 7/28/22 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 100A, NEMA-1, FUSED; FUSE RATING: 100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 " B THWN-2 2" PVC-40 4 / 6 C THWN-2 2" EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Monaghan, Kenneth �`',P "��� GREENLOGIC 2750 Nassau Point Road ENERGY Cutchogue, NY 11935 �,r zI 3 �o�� ELiMINATIRG THE COST OF EN.EkGY 1.) INITIAL SUBMITTAL WITH APPLICATION F OF Nan i Page 3 of 3 Drawing No: Monaghan-3LD1 Revision: 1 Revised: 7/28/22 SUMP W/ ER� 425-410 W Residential Black AC Module SunPower"Maxeon"Technology Built specifically for use with the SunPower Equinox system,the only fully integrated solution designed, engineered, and warranted by one company. Highest Power Density Available The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest-efficiency all-black AC solar module available.' A M Part of.,the SOOdwer { Eguiriox Solar System:`, s x.:. E - E 5% Seamless,aesthetics:>. I t:J lf: larger .a.: .<.Compatible yi+ici my5anPower manicoririg: - t ` Highest Lifetime Energy and Savings " il�� '' _. it o - _.... Designed to deliver 60/o more energy over 25 years in real-world conditions like partial shade and high temperatures.' "^5 t- Factory-integrated'. iVlcroinverter: ""u' Up to i Marc i Hi hest ower;irite rated; �; i (_itetime AC mouleiri solar' 'cnergY ;,,W <FEngineered aricl cali�rate'dY NCI by:S.unPowerfor.SunP,ower. ' s ' Year,of()perador: AG:modules i I Best Reliability,Best Warranty With more than 42.6 million and 15 GW of modules deployed around the world, SunPower technology is proven to last.That's why we stand behind our module and microinverter with the industry's best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. s. M425-BLK M415-BLK M410-BLK SunPower Residential Black AC Module X�Eleftrica!716ata Inverter Model:Type H(Enphase IQ7HS) @240 VAC @208 VAC Max.Continuous Output Power(VA) 384 369 Nom.(L-L)Voltage/Range'M 240/211-264 208/183-229 Max.Continuous Output Current(A) 1.60 1.77 Max.Units per 20 A(L-L)Branch Circuit" 10 9 CEC Weighted Efficiency 97.046 96.5% Nom.Frequency 60 Hz 60 Hz Extended Frequency Range 47-68 Hz 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A ..-.-......---- -- ---- Overvoltage Class AC Port III III AC Port Backfeed Current 18 mA 18 mA Power Factor Setting 1.0 1.0 Power Factor(adjustable) 0.85(Inductive)/0,85(capacitive) 0.8S(inductive)/0.85(capacitive) SPR-M425-BLK-H-AC SPR-M415-BLK-H-AC SPR-M410-BLK-H-AC 25-year limited power Warranty Nom.PowerG(Pnom)W 425 415 410 Warranties 25-year limited product warranty Power Tolerance +5/-O% +5/-0% +5/-0% UL 1741/IEEE-1547 UL 1741 AC Module Module Efficiency 22.0% 21.5% 21.2% UL 61730(Type 2 fire rated) Temp.Coef.(Power) -0.29%/•C -0.29%/•C -0.29%/•C UL 62109-1/IEC 62109-2 FCC Part 15 Class B Shade Tolerance Integrated module-level max.paver point tracking ICES-0003 Class B ' CAN/CSA-C22.2 NO.107.1-01 j CA Rule 21(UL 1741 SA)s Te� •s • • • • Certifications (includes Volt/Var and Reactive Power Priority) and UL Listed PV Rapid Shutdown Equipment? Operating Temp. -401 F to+1851 F(-40°C to+85•C) Compliance Max.Ambient Temp. 122•F(50•C) Enables installation in accordance with: j NEC 690.6(AC module) Max.Test Load' Wind:125 psf,6000 Pa,611 kg/mz back NEC 690.12 Rapid Shutdown(inside and outside the; Snow:187 psf,9000 Pa,917 kg/m2 front I array) Wind:75 psf,3600 Pa,367 kg/m2 back i NEC 690.15 AC Connectors,690.33(A)-(E)(1) Max.Design Load Snow:125 psf,5400 Pa,550 kg/mz front l When used with AC module Q Cables and accessories Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) ! (UL 6703 and UL 2238)7 l •Rated for load break disconnect ®• PID Test 1000 V:IEC 62804 Solar Cells 66 Maxeon Gen 6 • 8 • O • • 0 Front Glass High-transmission Tempered glass with anti-reflexive coating Environmental Rating Outdoor rated ; Modules per pallet 25 i Packaging box dimensions 75.4 x 42.2 x 48.0In.(1915 x 1072 x 1220 mm) Frame Class 1 black anodized(highest,4AMA rating) Pallet gross weight 1300 lb(590 kg) Weight 48 Ibs(21.8 kg) Recommended Max. Pallets per container 32 1.3 in.(33 mm) Module Spacing Net weight per container 18,880 kg 73.7 In -_"""--- 1 Based on datasheet revreviewof websites of top 20 manufacturers per IHS,as of July 2021. I 11872 rnm1 FRAME PROFILE 2 Maxeon 435 W,22 5%efficient,compared to a Conventional Panel on same-sized arrays(300 W,19%efficient, approx.1.6 m!),7.9%more energy per watt(based on PVSyst pan files for avg.US climate),0.596/yr slower degradation rate pordan,et.al."Robust PV Degradation Methodology and Apoiication:'PVSC 2018). Grounding Holes 3 Based on search of datasheet values from websites of top 10 manufacturers per IHS,as of June 2021. 4 Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 5 Factory se:to IEEE 1547a-2014 default settings.CA Pule 21 default settings profile sec during commissioning. ;p N 6 Standard Test Conditions It 000 W/m2 irradiarce,AM 1.5,25°q.NI DC voltage is fully contained within the module. 9 o l 7 LIL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12:and C22,i 2015 Rule 64-218 Rapid (A)Lang Side:1.3 in(32 mm) Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. Short Side:0.9 in(24 mm) 8 Please read the safety ano installation instructions for more information regarding load ratings and mounting configurations. j See vrnnv.sunpower.com!company for more reference Information. Please read the safety and installation nstnuctiors for details. For more details,see extended datasheet:,b%,,ay.stinpower.com/solar-resotirces. Specifications included in this datasheet are subject to change without notice. ,, c �a xr cart 02022 SunPower Corporation All rights reserved SUNPOWER,the SUNPOWERego and EQUINOX are U� w,,,P•s•`+.-a;r.N LISTED 544400 ReVA registered trademarks of SunPower Corporation in the U.S.MAXEON is a registered trademark of Maxeon Solar saieaw Technologies,Ltd For more information visitmAa.maxeon.com/legal. LModIiarirare&­­ryfez JanUafy2022 :ii '• o• a ,tea- 6'�. 1. '9 ., �.�r�Fn"'I�y•� � '°"/d %ef �:�� .y.5 "£at<.°...x^ ��i�`� ,w. . di £xti�..'f. v.�ry 5••�>w w tye�. 4µ` 9 -01M'�. .n� H Igor Yew• p ,� � i. l Simple and'Fast lns i tallation �i Integrated module-ro-rail grounding o Pre-assernhlGd mid and end damps Levitating mid clamp for easy pl;�cemenf, Mini clamp t^width Facilitares;consistent;even ° - module spaldrig SiMple,pre-drilled rail.splice i "L,2 70—Listed!ntegrated grounding ,Flexible'Design Addresses nearly all sloped res'dential roofs Design in landscapeand,portralt . Rails ert:ble e'asy obstacle management : . Customer-Preferred Aesthetics _-_m-_•,,-" A::.; _ . i;mocule and##' mounting aesthr_--tics Bes in-class system aesthetics Elegant Simplicity Premium,;loN-profile design Black anodized components SunPower' InvisiMountT"' is a SunPower-designed Hidden mid clamps andeend clamps rail-based mounting system.The InvisiMoi.�nt system and capped,flush rails ; addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics. ' Built for use with SunPower DC and AC modules The InvisiMount product was specifically envisioned and Best-in-class sysrem,reliadility.and'aesthetics' Combine wiiti SurnPoti•er modi.aes and engineered to pair with SunPower modules. The resulting monitoring app, system level approach will amplify the aesthetic and installation benefits for both homeowners and installers. I 3 , sunpower.com ® . p, "A' 'ii'Wit— v "XI! Z Module*IMid Clamp and Rail Module*1 End Clamp and Rail 'Ar Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly End Cal.) Component Material Weight T..e.mpera..tUr.e............................. (-40°F to 194* ...........3000 Pa uplift Load(LRFD) Max.Lo Mid Clamp Black oxide smiriless steel AISI 304 63 g(2.2 6000 Pa downlorce oz) .................... .............................. ...................... End Clamp Black anodized aluminum alloy 606---T6 110 g'3.88 oz) Rail Black anodized aluminum alloy r,)005-1,6 830 g/m(9 oz/ft) Rail Splice Aluminurri alloy 6005-75 830 g/m(9 oz/ft) 25-year product warranty warranties Lug 304 stainiess 106.5 g/ir,(3.75 oz) 5-year finizhv,)arrani:y Assembly (A2-70 bolt;tin-plated copper lug) End Cap l3iack acetal 11POlvi)copolymer 10.4 g(0.37 oz) UL 2703 Listed L Certifications ClassA Fire Rated.......................................................................................... .................------.......................———-----—------ Composition Shingle Rafter Aitachmenr Corri-nosition Shinty Roof Decking Actachnnera Application Curved and Flat Tile RoofAtrachmeric Universal Interface for Other roof Attacnrnents Refer to roof attachment hardware manufacturers documentation. i .............................................. '"'Module frame that is compal-A)k,wit th the InvislMount system required for hardware interoperability. 4) logo, ., 7015 Su:nPower'oj Poriflon. All Rights Reserved.SUNPOWER,the SUNPOWEER .ill INVISIMOUNT are trademarks or registered ti'an'c,marksofSt.inP,)werCorporation. All other trademarks are the property of their respective owners. stinpovver.com Specifications included in zhis datashee'ir are subject to change without notice. Document#509506 RevC TPOWEW �rz�-,>7 7- r_,� 4P Imorove Support, ...... ,',", -'--.Reduce Mainienance Costs SunPower EnergyLink...........Plug--and-Play Installation An intuitive monlco.ring website enables you to: . This complete solution for residential and commercial monitoring and -nap c -iei-sites see a visual i custon control includes the SunPower'L`PV Superviso! 6(P\/S6)which irnproves RernoWly manag�.,huncl!,eds oi'sites he installation P.,-cc,ss,over llsystern reliability,and cl is-orner a Receive elective system repo!ts experience. ipar t footprint for improved aesdhetics Locate sys,Lerr(iss1j.,s'and rennct�_-)'ydiagnlose, Cor-r 'Diagnosp issues on innRobust cloud connecdvty and comprehensive local connectivity Drill dowr,for the statics ref.i.ndi'vidual dev:ces Flexible configuration of devices during installation Consur.).Y. ption rrietering ............... Revenue-grade production metering(pending) Web-based commissioning Remote diagnostics of PVS6 and inverters -e reduces maintenance costs Durable UL Type 3R enclosur Easy integration with SunPower eBOS Add Value for:,Custorhe_rs .wth the SunPovver Nlonitoring,5ystern Robust Cloud Connectivity c jstcmers car.: Multiple options to ma'ntain optimal cec See what their solar co,nnivity: t sys�ern produces each 'd ye -clv& 'thern- ay,month,o:r a,r. I a. ied optimize.neir .solar.invesrmen, and,save on Wi-Fi energy exper-ses Cellular backup 5L e their energy use and estimated bill savings See their solar sVst.ern sper -rraqice using the':fc�r I SUnPow`er rr,onitorino wi?i's: e o I r rn o bile mop 7 3 r� SunPower Monitorinb Websites PVS6 SunPower AC Modules �. . .............r................................ . ........:...............:.....:...................:............:............ a ate; ..€•rsa�fi'� �� iltle v.. P i, ° k:• , li„.�'. �� :x Multiple communication options include `s` q i i Fri 7 Ethernet,Wi-Fi,and cellular. Number of SunPower AC modules 85 Temperature 220F to+140°F(-30*C to+60'Q supported per PVS6 Humidity(maximum) 95%,non-condensing High-speed Internet.access via accessible Internet access router or switch Paaver 100-240 VAC(L-N),50 or 60 Hz • 208 VAC(L-L in 3-phase),60 Hz RS-485 Inverters,and meters • one channel of revenue-grade production metering Integrated Metering • Tv,,,o channels of consumption meterinn(_..,. Weight 5.5 Ibs(2.5 kg,' Ethernet 1 LAN(or optional WAN'port Dimensions 11.8 x 8.0 x 4.2 in.(30.5 x 20.5 x 10.8 cm) PLC PLC for SunPower AC:modules Enclosure rating LJL5OE Type 3R _ Wi-Fi 802.11 btg,%n 2.4 GHz and 5 CHz _............................................._......._....----...._...................................._..__._..._......_........._.—.._........................ Cellular I..TF..Cat:-M*1,/3 G UMTS ZlgBee _ IEEE 802.15.4 MAC,2AGHz ISM band Data 131:orage 60 days Customer site monitor,us.sunpower.com --..... .... ......... ... __..._...._..._._.___._......___ _._...-.......-...._..._--_ rades Automatic firmware upgrades Partner site pvsr"ngrrit.us.sun pow,er.corri Upg Browsers Firefox,Safari,and Chrome Mobile devices tPhone�:read ,and Androi , Customer a _r F FP 1.Create account online at:mr�ntt ,,.,un ower.corr. 2.on a rnobile device,download the SunPoaver Monitonng Warranty 1 t year 1_imitsd 1l<rrant app from Apple App:torel"or Google Play' store. 3.Sign In using account entail and pass ��rd. Certifications UL,cUL,CE,UL 61010-1 and-2,FCC Part 15(Class B; FCC Lim FCC ID:YAW529O27 E5O3346 ! 1 ---------------------NEW EQUIPMENT ------------------� EXISTING SERVICE (TYPICAL SYSTEM SCHEMATIC, I 120/240, 1 PH, 3W FINAL INSTALLATION MAY VARY, I REQUIRES LOCAL AHJ ' AND UTILITY APPROVAL) I I 400A K W H lo PV—SA—1 ® A AC—COMBINER PANEL • AC—CMB-1 AC—DSC-1 N • . • 2 1 (PV ON B AC DISCONNECT C (EXTERIOR) TYP. PV ARRAY ^' PV—SA—N A I A B N BKR-1 I N • • • 2 1 I 200A 200A MAIN MAIN )--� BKR-N � I TYPICAL PV MODULE WITH I I NON— I A B N A B N INTEGRAL DC/AC INVERTER II FUSED BKR—M I I I BFB-1 II REA E IEGC B RI ' II N I II PM-1 I N N EGC D 1 1 I I MBJ EGC MBJ EGC I 9I MAIN C/T I I AC DISTRIBUTION I AC DISTRIBUTION —� I I I 1 NEW EGC I (NON—CRITCAL LOADS) I (NON—CRITCAL LOADS)I L- c -- 1 ---------------1#6CU MIN_-- ---------IF I ------- ������ ��LIRREVERSIBLE , ., —J BOND TYP � EXISTING�I GEC r� --- ------------------ — JUL - 7 ZOZ3 _ - ------- yP PACI J m � , 2 BUILDM D�ETP r. ARaFESS10aP PROPOSED_ 3—LINE ELECTRICAL DIAGRAM REVISIONS Monaghan, Kenneth GREENLOGICO 2750 Nassau Point Rd. Cutchogue, NY 11935 - & ENERGY 2.) REVISED AS BUILT ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 4 Drawing No: MNGHN-3LD1 Revision: 2 Revised: 6/23/2023 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 9.135 (PV) TOTAL KW RATING: (DC POWER) 10.150 (PV) CITY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-X21_-350-BLK-E-AC 29 PV MODULE: 350 W DC(NOMINAL), EACH ENPHASE BRAND, MODEL: IQ-7XS 29 PV INVERTER: (INTEGRAL TO MODULE) 315 VA, 1.31 A, 240V AC, EACH _ L REVISIONS Monaghan, Kenneth GREENLOGICO 2750 Nassau Point Rd. ENERGY Cutchogue, NY 11935 2.) REVISED AS BUILT ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 4 _ Drawing No: MNGHN-3LD1 Revision: 2 Revised: 6/23/2023 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X21-350-BLK-E-AC, 1-CIRCUIT OF 4-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X21-350-BLK-E-AC, 1-CIRCUIT OF 6-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X21-350-BLK-E-AC, 1-CIRCUIT OF 8-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X21-350-BLK-E-AC, 1-CIRCUIT OF 11-MODULES PM-1 PRODUCTION MONITORING SYSTEM SUNPOWER PVS6, POWER MONITOR AC-CMBP AC COMBINER PANEL 250V, 100A, MAIN-LUG, NEMA-1, 1-PH, 3-WIRE BKR-1...BKR-4 CIRCUIT BREAKER, PV-SA-1 ... PV-5A-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-M CIRCUIT BREAKER, PRODUCTION MONITOR MATCH AC COMBINER PANEL BRAND, 2-POLE, 15A BFB-1 CIRCUIT BREAKER, GRID-TIE BREAKER, MATCH MAIN PANEL BRAND, RATING: 2-POLE, 50A AC-DSC-1 AC DISCONNECT SWITCH (EXTERIOR) 250V, 60A, DISCONNECT SWITCH, NEMA-311, NON-FUSED REVISIONS Monaghan, Kenneth GREENLOGIC® 2750 Nassau Point Rd. ENERGY Cutchogue, NY 11935 2.) REVISED AS BUILT ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 4 Drawing No: MNGHN-3LD1 Revision: 2 Revised: 6/23/2023 1 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 1,260 WATTS 211-264 VAC 5.24 A AC 240 V,AC PV-SA-2 1,890 WATTS 211-264 VAC 7.86 A,AC 240 V,AC PV-SA-3 2,520 WATTS 211-264 VAC 10.48 A AC 240 V,AC PV-SA-4 3,465 WATTS 211-264 VAC 14.41 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE AWG. / EGC A NMB 12 / 12 J B NMB 6;/_ -6 C NMB 6 /�6 D NMB 14 / 14 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM REVISIONS Monaghan, Kenneth - GREENLOGICS) 2750 Nassau Point Rd. ENERGY Cutchogue, NY 11935 2.) REVISED AS BUILT ELIMINATING THE COST OF'ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 4 of 4 Drawing No: MNGHN-3LD1 Revision: 2 Revised: 6/23/2023 GREENLOGICO ENERGY ,n�^��% January 31, 2024 2024 FEB Town of Southold Building Department ; c? {°r '" Town Hall ~y 53095 Route 25 Southold, NY 11971 Project Info: Kenneth Monaghan 2750 Nassau Point Road Cutchogue, NY Permit:48924 Dear Building Inspector: Enclosed please find the below revised documents as the system changed along with the engineer certification. • 2 Amended Plansets • 2 Spec. sheets of the solar panels Please let us know if you need anything else in connection with this application. Yours truly, J3avcPwm ewciotta Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC•www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S.Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 ---------------------NEW EQUIPMENT -------------------� EXISTING SERVICE I (TYPICAL SYSTEM SCHEMATIC, I 120/240, 1 PH, 3W I FINAL INSTALLATION MAY VARY, I REQUIRES LOCAL AHJ AND UTILITY APPROVAL) L 400A KWH PV-SA-1 A AC-COMBINER PANEL - AC-CMB-1 AC-DSC-1 1 (PV ONLY ID AC DISCONNECT C L (EXTERIOR) TYP. PV ARRAY I I I I PV-SA-NFm 4- - BKR-1 A B N , I ff• • • f] 1 IMAIN MAIN200A 200A L ----- - --I I BKR-N I TYPICAL PV MODULE WITH I I NON- I A B N A B N INTEGRAL DC/AC INVERTER I I FUSED I I BKR-M I1 II I BFB-1 EGC I I I I BREAk ER II N I I I PM-1 N N I I EGC D I I I I �MBIJE�GC MBJ EGC II I I MAIN C/T I I AC DISTRIBUTION I AC DISTRIBUTION I 1 I I I I NEW EGC --�(NON-CRITCAL LOADS) I (NON-CRITCAL LOADS)I --------- ----------------L� #6CU MIN ----I T--- ql� IRREVERSIBLE BOND, TYP. EXISTING GEC PA y��SF' �PA �V w Tl �•�S'G�E .�„ z 2s��'°poRFss o�Ay���. PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Monaghan, Kenneth - 2750 Nassau Point Rd. ENERGY ER Cutchogue, NY 11935 2.) REVISED AS BUILT ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 4 1 t?jS Drawing No: MNGHN-3LD1 Revision: 2 Revised: 6/23/2023 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 9.135 (PV) TOTAL KW RATING: (DC POWER) 10.150 (PV) QTY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-X21-350-BLK-E-AC 29 PV MODULE: 350 W DC (NOMINAL), EACH ENPHASE BRAND, MODEL: IQ-7XS 29 PV INVERTER: (INTEGRAL TO MODULE) 315 VA, 1.31 A, 240V AC, EACH Monaghan, Kenneth REVISIONS 2750 Nassau Point Rd. GREENL® GY Cutcho ue NY 11935 �N�RG� g 2.) REVISED AS BUILT ELIMINATING THE COST OF-ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 4 Drawing No: MNGHN-3LD1 -Revision: 2 Revised: 6/23/2023 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-X21-350-BLK-E-AC, 1-CIRCUIT OF 4-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-X21-350-BLK-E-AC, 1-CIRCUIT-OF 6-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-X21-350-BLK-E-AC, 1-CIRCUIT OF 8-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-X21-350-BLK-E-AC, 1-CIRCUIT OF 11-MODULES PM-1 PRODUCTION MONITORING SYSTEM SUNPOWER PVS6, POWER MONITOR AC-CMBP AC COMBINER PANEL 250V, 100A, MAIN-LUG, NEMA-1, 1-PH, 3-WIRE BKR-1...BKR-4 CIRCUIT BREAKER, PV-SA-1 ... PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-M CIRCUIT BREAKER, PRODUCTION MONITOR MATCH AC COMBINER PANEL BRAND, 2-POLE, 15A BFB-1 CIRCUIT BREAKER, GRID-TIE BREAKER, MATCH MAIN PANEL BRAND, RATING: 2-POLE, 50A AC-DSC-1 AC DISCONNECT SWITCH (EXTERIOR) 250V, 60A, DISCONNECT SWITCH; NEMA-311, NON-FUSED Monaghan, Kenneth REVISIONS GRENLOGIC 2750 Nassau Point Rd. E ENEROY Cutchogue NY 11935 2.) REVISED AS BUILT ELIMINATING THE-00ST'OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 4 Drawing No: MNGHN-3LD1 Revision: 2 Revised: 6/23/2023 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER MAX VOLTAGE MAX.AC VOLTAGE NOMINAL RANGE CURRENT ' PV-SA-1 1,260 WATTS 211-264 VAC 5.24 A AC 240 V,AC PV-SA-2 1,890 WATTS 211-264 VAC 7.86 A AC 240 V,AC PV-SA-3 2,520 WATTS 211-264 VAC 10.48 A AC 240 V,AC PV-SA-4 3,465 WATTS 211-264 VAC 14.41 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE AWG. / EGC A NMB 12 / 12 B NMB 6 / 6 C NMB 6 / 6 D NMB 14 / 14 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM Monaghan, Kenneth REVISIONS 2750 Nassau Point Rd. &(GR E E L® I. Cutchogue, NY 11935 ���� 2.) REVISED AS BUILT ELIMINATING 7HE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 4 of 4 Drawing No: MNGHN-3LD1 Revision: 2 Revised: 6/23/2023 Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave,Suite 2B MIG Ph:631-988-0000 Bohemia, NY 11716 c solar@pacificoengineering.com April 21,2023 Town of Southold Building Department 54375 Route 25,P.O.Box 1179 Southold,NY 11971 Subject: Solar Energy Installation for Kenneth Monaghan 2750.Nassau Point Road Cutchogue,NY 11935 I have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions.I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE 7-16 when installed in accordance with the manufacturer's instructions. -- Roof Section A B C D Mean roof height 16.0 ft 22.0 ft 16.0 ft 22.0 ft Pitch 17 degrees 30 degrees 50 degrees 36 degrees Roof rafter 2x10 2x8 2x10 2x10 Rafter spacing 16 inch on center 16 inch on center 16 inch on center 16 inch on center Reflected roof rafter span 13.7 ft 8.6 ft 5.2 ft 7.5 ft Table R802.4.1(1)max allowable 22.5 ft 18.5 ft 22.5 ft 22.5 ft SS 5/16"dia lag bolt, SS 5/16"dia lag bolt, SS 5/16"dia lag bolt, SS 5116"dia lag bolt, Fastener Type 4-3/4"length 4-3/4"length 4-3/4"length 4-3X'length Fastener Capability 1067 lb 1067 lb 1067 lb 1067 lb Fastener Spacing,Zone 1/2/3 64164/64 in 64/64/64 in 64/64/64 in 64/64164 in Point Pullout,lb,Zone 1/2 13 274/383/588 lb 288 1342/342 lb 301/342/342 lb 288/342/342 lb Zone Category 112/3 1 /2/3 1 /2/3 1 /2/3 1 /2/3 Uplift Pressure Zone 112/3 20/28/43 psf 21 /25/25 psf 22/25/25 psf 21 /25/25 psf Exposure Category C Ground Snow Load,Pg 20 psf Wind Speed,3 sec gust 130 mph 0-9 OF W�y y, array dead load 3.5 psf �Q' pH PACj e) load per attachment 47.9 lb The subject roof has 1 layer of roofing. Panels mounted flush to roof no higher than 6 inches above roof surface. n Ralph Pacifico,PE Professional Engineer �A • �618 v Ralph ngineer NY 066182 GREENLOGIC@j ENERGY GreenLog/c,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#A: Total System Size:10.150kW Array Size:3.850kW 1 circuit of 11 on a 20A breaker Azimuth:235" Pitch:17" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X21-350-BLK-E-AC Racks ng:SunPower Invisimount Panel:61.3"X 41.2" Array:15'5 5/8"X 13'11" Surface:22'5"X 15'10" Ma is#:Invisimount Legend: ® 11 SunPower 35OW Panels — SunPower Invisimount Rail • 30 IronRidge Flash Foot 2 00 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used.:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: PA 2C? • ;�A 066182 v� 9�FESS�ON Drawn By:MMB Drawing#1 of 14 Date:4/20/2023 REV:B Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#A: Total System Size:10.150kW,, Array S¢e:3.850kW . 1 dreuit of 11 on a 20A breaker Aamuth:235° Pitch:17" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X21-350-BLK-E-AC Racking:SunPowerinvisimount Panel:61.3"X 412' Array:15'5 5/8"X 13'11" Surface:22'5"X 1610" Ma is#:Invisimount Legend: ® 11 SunPower 350W Panels SunPower Invisimount Rail 30 IronRidge Flash Foot 2 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf EnWinzw A&w&kectSeal• o NE J. rA `�� G6818`� a►' ARQFES�tON���r Drawn By:MMB Drawing#2 of 14 Date:4/20/2023 REV:B Drawing Scale:1/4"=1.0' GREENLOGIC ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2760 Nassau Point Road Cutchogue,NY 11935 Surface#A: Total System Size:10.150kW Array Size:3.850kW 1 circuit of 11 on a 20A-breaker Azimuth:235" Pitch:1 r Monitoring System: SunPower 1 Pand/Array Specifications: Panel:SPR-X21-35MLK-E-AC Racking:SunPower invisimount Panel:61.3"X 41.2" Array:15'5 5/8"X IS 11" Surface:22'5"X 15'10" Ma ic#.Invisimount - 1 Legend: ® 11 SunPower 350W Panels SunPower lnvisimount Rail • 30 IronRidge Flash Foot 1 1 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 Psf 1 Engineer/Architect Seal: R,4Q0 -- S10�P Drawn By:MMB Drawing#3 of 14 Date:4/20/2023 REV.'B Drawing Scale:114"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#B: Total System Size:10.150kW Array Size:2.100kW 1 ci rcuit of 6 on a 20A breaker Azimuth:145" Pitch:30° ti Monitoring System: SunPower PanellArray Specifications: Panel:SPR-X21-350-BLK-E-AC Racki ng:SunPower Invisimount Panel:61.3"X 41.2" Array:15'5 5/8"X 8'7 5/16" Surface:26'5"X 10'8" Ma is#:Invisimount L end: ® 6 SunPower 35OW Panels SunPower Invisimount Rail 14 IronRidge Flash Foot 2 W'Douglas Fir Rafter 16"O.C. _ Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf En i9 eal: RAC/Fi�,��' A��F�SSi P Drawn By:MMB Drawing#4 of 14 Date:4/2012023 REV.B Drawing Scale:1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#B: Total System Size:10.150kW Array Size:2.100kW 1 circuit of 6 on a 20A breaker Azimuth:145" Pitch:30' Monitoring System: SunPower PandIAEff Specifications: Panel:SPR-X21-350-BLK-E-AC Racking:SunPowerinvisimount Panel:61.3"X 41.2" Array:16 5 5/8"X 8'7 5116" Surface:2V 5"X 10'8" Magic it Invisimount Legend: ® 6 SunPower 35OW Panels SunPower Invisimount Rail • 14 IronRidge Flash Foot 2 11 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: OF PJP- DIA PA rti •� :spi/-SY: essl Drawn By:MMB Drawing#5 of 14 Date:4/20/2023 REV.B Drawing Scale:1/4"=1.9 GREENLOGIC" ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#B: Total System Size:10.150kW Array Size:2.100kW 1 circuit of 6 on a 20A breaker Azimuth:145" Pitch:30" ti Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X21-3%BLK-E-AC Racking:SunPower Invisimount Panel:61.3"X 41.2" Array:16 5 5/8"X 8'7 5116" 2 Surface:26'5"X 1 Y 8" Ma is#Invisimount Legend: ® 6 SunPower 35OW Panels SunPower Invisimount Rail • 14 IronRidge Flash Foot 2 00 2x8"Douglas Fir Rafter 16"O.C. 2 Notes: Number of Roof Dyers:1 Height above Roof Surface:4" Materials Used:IronRldge,SunPower Added Roof load of PV System:2.31psf Engineer hitect Seal: Vk f Ar s T' Drawn By:MMB Drawing#6 of 14 Date:4/20/2023 REV.B Drawing Scale:11,V=1.V GREENLOGIC" ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#C: Total System Size:10.150kW Array Size:2.800kW 1 circuit of 8 on a 20A breaker Azimuth:145" Pitch:50" 2 Monitoring System: SunPower Pand/Array Specifications: Panel:SPR-X21-350-BLK-E-AC Racking:SunPower Invisimount Panel:61.3"X 41.2" Array:29 7 Y4"X V 11 1/8" Surface:25'3"X 9'10" Ma is#:Invisimount Legend: 8 SunPower 350W Panels SunPower Invisimount Rail • 20 IronRidge as Foot2 X�7 77- ----------- 2x10"Douglas Fir Rafter 16"O.C. 77- Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf En ineer itect Seal: Of NEF S1���� Drawn By:MMB Drawing#7 of 14 Date:4/20/2023 REV:B Drawing Scale:114"=1.9 GREENLOGIC® ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#C: Total System Size:10.150kW Array Size:2.800kW 1 circuit of 8 on a 20A breaker Azimuth:145" Pitch:50" 2 Monitoring System: SunPower Pand/Array Specifications: Panel:SPR-X21-350-BLK E-AC Racking:SunPower lnvisimount Panel:61.3"X 41.2" Array:20'7'/++"X 6'11 1/8" Surface:26 TX 9 10" Ma is#.invisimount Legend: ® 8 SunPower 350W Panels SunPower Invisimount Rail • 20 IronRidge Flash Foot 2 8 2x10"Douglas Fir Rafter 16"O.C. NI Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf En inserlArchitect Seal: �dFESS1oN�► Drawn By:MMB Drawing#8 of 14 Date:4/20/2023 REV:B Drawing Scale:1/4"=1.0' et C GREENLOGICQD ENERGY GleenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#C: Total System Size:10.150kW Array Size:2.800kW 1 circuit of 8 on a 20A breaker Azimuth:145" Pitch:50" Monitoring System: SunPower jo PanellArra -Specifications: Panel:SPR-X21-350-BLK-E-AC Racking:SunPowerinAsimount Panel:61.3"X 41.2" Array:20'7 3/4"X V 11 1/8" Surface:25'3"X 9'10" 3 Ma ic#invisimount L end: ® 8 SunPower•35OW Panels SunPower Invisimount Rail • 20 IronRidge Flash Foot 2 3 B 2x10"Douglas Fir Rafter 16"O.C. Notes Number of Roof Layers:1 \ Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf En ineerl itect seal: PA 1' M .> Drawn By:MMB Drawing#9 of 14 Date:4/20/2023 REV.B Drawing Scale:l/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road . Cutchogue,NY 11935 Surface#D: Total System Size:10.150kW Array Size:1.400kW 1 circuit of 4 on a 20A breaker Azimuth:145" Pitch:36" Monitoring System: SunPower 0 , Panel/Array Specifications: Panel:SPR-X21-350-BLK-E-AC Racking:SunPower Invisimount Panel:61.3"X 41.2" Array:10'3'W X 6 11 118" Surface:15'9"X 10'2" Magic It Invisimount Legend: ® 4 SunPower 35OW Panels SunPower lnvisimount Rail • 12 IronRidge Flash Foot 2 10 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf Engineer/Architect Seal: �+�.. . ' t 0 Drawn By:MMB Drawing#10 of 14 Date:4/20/2023 REV:B Drawing Scale:1/4"=1.9 GREENLOGIC® ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#D: Total System Size:10.150kW Array Size:1.400kW 1 ci rcuit of 4 on a 20A breaker Azimuth:145° Pitch:36" Monitoring System: jo SunPower Panel/Array Specifications: Panel:SPR-X21-350-BLK E-AC Racking:SunPowerinvisimount Panel:61.3"X 41.2" Array:1 V 3%_"X 6'11 1/8" Surface:15'9"X 10'2" Magic#:Invisimount Legend: ® 4 SunPower 35OW Panels SunPower lnvisimount Rail • 12 IrcnRidge Flash Foot 2 8 I 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf En ineeriArchitect Seat: PA it Drawn By:MMB Drawing#11 of 14 Date:4/20/2023 REV.B Drawing Scale:1/4"=1�.0' ew C GREENLOGICO ENERGY GreenLogfc,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Surface#D: Total System Size:10.150kW Array Size:1.400kW 1 circuit of 4 on a 20A breaker i I Azimuth:145° Pitch:36° Monitoring System: SunPower 01 Pand/Array Specifications: Panel:SPR-X21-350-BLK-E-AC Racking:SunPower Invisimount Panel:61.3"X 41.2" Array:10'31/"X 6'11 1/9' Surface:15'9"X 10'2" 4 Ma is#:Invisimount Legend: ® 4 SunPower 35OW Panels SunPower lnvisimount Rall • 12 IronRidge Flash Foot 4 B I 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IrcnR!dge,SunPower Added Roof load of PV System:2.31 Psf Engineer/Architect Seal: PA Qrr aSt� � Drawn By:MMB Drawing#12 of 14 Date:4120/2023 REV:B Drawing Scale:1/4"=1.0' No Vent Pims Will Be Covered By The Solar Array GREENLOGICO ENERGY Legend: GmenLoglc,LLC Approved Monaghan,Kenneth AR-Access Roof AP-Access pathway,36" minimum width SVO—Setback at ridge 2750 Nassau Point Road per R202 definitions per R324.6.1 as per R324.6.2.1 Cutchogue,NY 11935 Total System Size:10.150kW 1 circuit of 11 on a 20A breaker 1 d rcuit of 8 on a 20A breaker 1 circuit of 6 on a 20A breaker I 1 circuit of 4 on a 20A breaker API IAP I Azimuth:145" L————I Monitoring System: y SunPower Pand/Array Specifications: Panel:SPR X21-350-BLK-E-AC Racking:SunPowerinvisimount Panel:61.3"X 41.2" 4 SunPower Vr a. Magic#:Invisimount 350W Panels —a-- L end: ——————————— J ® 29 SunPower 350W Panels qvn —— I — SunPower Invisimount Rail I • 76 IronRidge Flash Foot 2 91 2x10"Douglas Fir Rafter 16"O.C. I I 0� 2x8"Douglas Fir Rafter 16"O.C. Notes: 6 SunPower I Number of Roof Layers:1 35OW Panels I Height above Roof Surface:4" Materials Used:IronRidge,SunPower ———a—— Added Roof load of PV System:2.31 psf En anew/Architect Seal: of CIAP 11 SunPower 35OW Panels ----------� g�+ ^ _ »,,• Meter9ti 8 SunPower -.. 35OW Panels Drawn By:MMB Drawing#13 of 14 Date:4/20/2023 REV.B Drawing Scale:1/16"=1.9 GREENLOGICO' ENERGY GreenLogic,LLC Approved Monaghan,Kenneth 2750 Nassau Point Road Cutchogue,NY 11935 Total System Size:10.150kW 1 ci rcuit of 11 on a 20A breaker 1 circuit of 8 on a 20A breaker JOB MATERIAL LIST 1 circuit of 6 on a 20A breaker 1 circuit of 4 on a 20A breaker Azimuth:145" Monitoring System: SunPower 0- Pand/ArmySpecifications: Material Ust qty. Rail Material Ust , QW. Panel:SPR-X21-350-BLK E-AC Racking:SunPowerinvisimount Panel:61.3"X 41.2" Magic#:Invisimount Cast Aluminum Mounting Block w/BlackAluminum Flashing 76 5/16"x0.75"Fender Washer 76 Legend. 5/16"x4.75"Hex-Head Lag Screw 76 ® 29 SunPower 35OW Panels SunPower lnvisimount Rail • 76 IrcnRidge Flash Foot 2 0 2x10"Douglas Fir Rafter 16"O.C. 0 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:IronRidge,SunPower Added Roof load of PV System:2.31 psf En -nser Ancbttect Seal: i. a✓ Drawn By:MMB Drawing#14 of 14 Date:4/20/2023 REV:B Drawing Scale:1/16"=f.01 `