Loading...
HomeMy WebLinkAbout50189-Z OgOFFDI/'cpG Town of Southold 2/10/2024 a y�, P.O.Box 1179 o o _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44972 Date: 2/10/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 375 Elizabeth Ln, Southold SCTM#: 473889 Sec/Block/Lot: 78.-5-4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/6/2023 pursuant to which Building Permit No. 50189 dated 1/8/2024 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Spitzenberg,Robert&Irene h , of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50189 1/10/2024 PLUMBERS CERTIFICATION DATED Auth i d 6'gn ture �o�S�FFol,t�o TOWN OF SOUTHOLD oy BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE o • SOUTHOLD NY BUILDING PERMIT ,(THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50189 Date: , 1/812024 Permission is hereby granted to: Spitzenberg, Robert 344 Terry Ct Southold, NY 11971 To: Install an accessory standby generator to an existing single-family dwelling as applied for per manufacturers specifications. r I At premises located at: 375 Elizabeth Ln, Southold SCTM #473889 Sec/Block/Lot# 78.-5-4 Pursuant to application dated 12/6/2023 and approved by the Building Inspector. To expire on 7/9/2025. Fees: ACCESSORY $125.00 CERTIFICATE OF OCCUPANCY $100.00 ELECTRIC $100.00 Total: $325.00 Building Inspector *pF SO(/r�,ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q % • �o sea n.deviin(&-town.southold.ny.us Southold,NY 11971-0959 �y�OUNT`I,N BUILDING DEPARTMENT. TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Robert Spitzenberg Address: 375 Elizabeth Ln city:Southold st: NY zip: 11971 Building Permit* 50189 Section: 7$ Block: 5 Lot: 4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Peconic Power Systems License No: 45056ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Generator X INVENTORY Service.1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel 50A A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 10kW Generac Generator w/ 50A 16 Circuit Generator Panel Notes: Generator Inspector Signature: Date: January 10, 2024 S.Devlin-Cert Electrical Compliance Form pF SOUIyOIo �I ) 75 # # TOWN OF S UTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: DATE 1611 INSPECTOR �F SODTy�Io * # TOWN OF SOUTHOLD BUILDING DEPT. �ycou 631-765-1802 0( 51 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINALb&4VU4'4Vt-'-' [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: lu DATE I INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS c v I Ci7 FOUNDATION (1ST) �y ----------------------------------- \ C FOUNDATION (2ND) COO z 0 _ ROUGH FRAMING& PLUMBING r� 11 r INSULATION PER N.Y. y STATE ENERGY CODE 15z 0 �1 FINAL rr __ ADDITIONAL COMMENTS lU �O z rn 1 ►moo N (� O z x a x d b �osufFnc,r 0oG��. TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 -Telephone(631) 765-1802 Fax (631) 765-9502 hns://www.southoldtowm.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only EC El V E PERMIT NO. 5 Building Inspector: DEC — 6 2023 Applications and forms must be filled'out in their entirety: Incomplete applications will not be accepted. Where the Applicant is,not the owner,an, _ Building®epaatrreent Owner's,Autliorizetion form(Page•2)shall be completed. Town of Southold Date: .OWNER($)OF PROPERTY: Name: SCTM#1000- Project Address: Phone#: _J/(a Email: Mailing Address: J?t� — u�� SO_Ua— Nil CONTACT PERSON: Name: Mailing Address: 30 ovr#_r-r�d_�__.. Phone#: _ �. - !� j(/� EmaiJ`� �1%L ��I -- DESIGN PROFESSIONAL INFORMATION: Name: 644ST7dL Mailing Address _ 7^ P&ke L-Sr Phone;#: _s ' 3a/ ��7�� Email: CONTRACTOR INFORMATION: J Name: Mailing Address: Phone#: Email: DESCRIPTION.OF PROPOSED.CONSTRUCTION .,. ❑New Structure ❑Addition ❑Alteration ❑Repair. ❑Demolition Estimated Cost of P�Loject: []other $ /(orw''84;to6 Will the lot be re-graded? ❑Yes RNo — — Will excess fill be removed from premises? ❑Yes VfN0 1 - PROPERTY INFORMATION Existing use-of property: tended use of property Zone or use district in which premises is situatidd: Are there any covenants and restri ' s wit respect to this property? ❑Yes ZI'No IF YES, PROVIDE A COPY. 0.Check Box After,Reading:.The.owner/contractor/design professional is re'sponsible,for all drainage;and storm water issues as provided by Chapter,236;of the'Town Code. APPLICATION,IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to-the Building Zone. 'Ordinances Lf th"et"rovdn o t u ild, ffolk;•County,,New York and other applicable Laws,Ordinances,or Regulations;for,the construction of buildings, additions; Iterotwn l r to re va j d4molition'as herein described:The applicant agrees to comply with all applicable laws,ordinances;building code, housing code and regulations and to admit auihoriied�inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor'pursuant to Section 210.45 of the New York State Penal Law. Applicationtubm tted'g3,('Orint name): /p ❑Authorized Agent 00wner Signature of Applicant: Date: _ Z STATE OF NEW YORK) S - COUNTY OF c, ) being duly sworn, deposes and says.that.(s)he is the applicant (Name of individual signing contrac above named, (S)he is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work,and:to make and file this application;that all statements contained in this application are true to the best of his/her.knowledge and belief; and that the work will be performed in the manner setforth in the application file therewith.; Sworn before me this day of .lJcc c" C-( , 20;--:�> Notary Pul lic' Rebecca A. Lucak Notary'Public, State of New York 882 PROPERTY OWNER AUTHORIZATION Reg,eci in udolk County Qualified in Suffolk County (Where the applicant is not the owner) Commission Expires 02/04/2027 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. r Owner's Signature Date Print Owner's Name 2 T BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh(cb-southoldtownny.gov -• seand(c-Dsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 12/6/23 Company Name: Peconic Power Systems Electrician's Name: Robert Stanevich License No.: ME-45056 Elec. email:Peconicpowersys@gmail.com Elec. Phone No: 516-819-7191 ❑1 request an email copy of Certificate of Compliance Elec. Address.: PO Box 512 Cutchogue NY 11935 JOB SITE INFORMATION (All Info`rmation/Required) Name: , A,-,-� 5PI Address: 3 7 /;L;L 4 Cross Street: G✓e v.,Gam.. Phone No.: 3'1.1 I b y BIdg.Permit#: - 5p 118 email: G,,,,� -� •(�, Tax Map District: 1000 Section: Block: 5 Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New 10KW Generac generator with 50 amp 16 circuit transfer switch Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire Reconnect❑Flood Reconnect[]Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 D H Frame Pole Work done on Service? El Y MN Additional Information: PAYMENT DUE WITH APPLICATION r � Fl�t BUILDING DEPARTMENT- Electrical Inspector ��® G TOWN OF SOUTHOLD o Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh(&-southoldtownny_,gov — sea nd(a southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ail Information Required) Date: 12/6/23 Company Name: Peconic Power Systems Electrician's Name: Robert Stanevich License No.: ME-45056 Elec. email:Peconicpowersys@gmail.com Elec. Phone No: 516-819-7191 ❑I request an email copy of Certificate of Compliance Elec. Address.: PO Box 512 Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name: u c ,7 `1 b r Address: 3 7 4 4 Cross Street: 6✓41,,e—411 w.. Phone No.: ,S/,/ 7b y Bldg.Permit#: Sp I Clemail:G� C .6 Tax Map District: 1000 Section: Block: 5, Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New 10KW Generac generator with 50 amp 16 circuit transfer switch Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES ❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 R2 F1 H Frame Pole Work done on Service? OY RN Additional Information: PAYMENT DUE WITH APPLICATION �4 / SURVEY.OF PROPERTY 00 SITUATE 100 ' SOUTHOLD TOWN OF SOUTHOLD ��o° (°� /' •• :' '.\ , SUFFOLK COUNTY, NEW YORK 4 4 / •'yd°<. ?!, S.C. TAX No. 1000-78-05-04 ;� , ! SCALE 1'=20' AP / OCTOBER 26.2023 � ••\ TOTAL AREA= 21.679 sq. fl. 0.498 oc. BUILDABLE AREA= 19.540 sq. ft. 1A 9•Y 6 / ..4� �.. i y •� m� CERTIFIED TO, ROBERT F.SPIIZENBERC `V PROPOSED COVERAGE DATA �� � p•r� 4? OVER BUILDABLE AREA (1 t),s40 sq. ft.) �,.,'�. '<. / •• �,',� y. +:•• DESCRIPTION AREA X LOT COVERAGE[ / 4 n ',��. ��s 1 •••! ,, �. cf HOUSE 1,546 sq. ff. 7.9% ,��y;.� \\1:',i.•+pd' ��:' s REAR RAISED WOOD DECK 330 sq. ft. 1.7X u' ���MMMMp "do-• ' , \ PROPOSED FRONT PORCH 109 sq.fl. 0.6% • ?! V`(� 1 c1 \ �p TOTAL 1,985 sq.f(. 10.2% .:.l0e ". ItV TYN�y M v:o s.racNs,aaN sw m na�m v..aNa,Nr a:mNsm® y m:awn n¢asc �� •�••�• yAJ 7q Mani mm�C®I M,bMe Y at 0 M p�p�a iso1l a�1vs 9� � YO/Ol asOmlrs a Ism.v Nf/XCf 9101Y II6 NCI W�GMI®. ry Nathan Taft Corwin M Land Surveyor . =tea.4uim•��BLS P11 M(631)717-2M Fs(631)727-1727 QFRS LOOM Ar ltVLLm AOOIRQ 13M"— FA Bm 10 Jmnscal Nn Tat"m Ja—m%N Tat 1160 6TS Ilc.Nv.CO,EC E-Wl NWdNOadl ;aco CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIYYYY) 06/15/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: Josh Mitchell Freedom Coverage Corp PHONE 631)709-2777 a No): _ 80 Orville Dr Suite 100 (A&NQ s: . Josh@Fr eedomCoverageNY.com Bohemia, NY 11716 INSURERS AFFORDING COVERAGE NAIC# INSURERA: Midvale Indernity Company 27138 INSURED INSURERS: The Hartford Ins Company 29424 Peconic Power Systems LLC INSURER C: 315 Commerce Rd INSURERD: Cutchogue, NY 11935 INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: 00000166-206682 REVISION NUMBER: 18 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INTRR TYPE OF INSURANCE ADOL SUBR POLICY NUMBER MM/LDDY� MMLDD EXP LIMITS A X COMMERCIAL GENERAL LIABILITY GLP1092481 05/28/2023 05/28/2024 EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCUR DAMAGE T RENTED PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1 000 000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 1,000,000 POLICY a JE OT- LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per acc dent $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DIED I I RETENTION$ $ B WORKERS COMPENSATION 12WECAT7UBP 09/02/2022 09/02/2023 X STATUTE OT ER AND EMPLOYERS'LIABILITY ANY PROPRIETORIPARTNER/EXECUTIVE Y/N E.L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached U more space is required) As pertains to insureds operations CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold Building Department THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town Hall Annex 54375 Main Road ACCORDANCE WITH THE POLICY PROVISIONS. P.O. Box 1179 Southold, NY 11971 AUTHORIZED REPRESENTATIVE Ii/�fL JCM @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and'logo are registered marks of ACORD Printed by JCM on 06/15/2023 at 11:23AM _R COMPLY WITH ALL CODES OF APPROVED AS NOTED NEW YORK STATE&TOWN CODES g AS REQUIRED AND CONDITIONS OF DATE: (� _a B.P.# 6 C) ,,,,,,.,,r,S0UiH0I,4141M+I I8A FELL5.oo BY X SOUiHOLD1I�YVNPIANNING80ARD NOTIFY BUILDING DEPARTMENT AT 631-765-1802 BAM TO 4PM FOR THE KY1 DI C FOLLOWING INSPECTIONS: FOUNDATION-TWO REQUIRED FOR POURED CONCRETE ROUGH-FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS ELECTRICAL INSPECTION REQUIRED GENERAC® GUARDIAN° SERIES 10/13/16 W Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating GG07171-0.G007172-0(Aluminum-Bisque)—10 kW 60 Hz • True Power" Electrical Technology G007173-0,G007174-0,G007175-0(Aluminum-Bisque)—13 kW 60 Hz • Two-line multilingual digital LCD Evolution controller G007176-0.G007177-0,G007178-0(Aluminum-Bisque)—16 kW 60 Hz "" (English/Spanish/French/Portuguese) • Two transfer switch options available: 100 amp 16 circuit switch or ` 200 amp service rated smart switch • Electronic governor • Standard Wi-Fi'" connectivity • System status&maintenance interval LED indicators .a�.A... • Sound attenuated enclosure � • ;�: ti�'.:. ,. €�;:,;�,_�,,;--�;h�...;: • Flexible fuel line connector 3 u 'rtGENERAC • Natural gas or LP gas operation )' ' • 5 Year limited warranty l: • Listed and labeled by the Southwest Research Institute ON ugor C �L US Q/ /�G�allowing installation as close as 18 in (457 mm) to a c LISTED V L � structure. *Must be located away from doors, windows,and fresh air Note:CETL or CUL certification only applies to unbundled units and units packaged with limited intakes and in accordance with local Codes. circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. https:llassets.swri.org/l`ibraryIDirectoiyOfListedProducts/ Constructionindustryl973_DOC-204-13204-0 1-0 l_Rev9.pdf i FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This Generac's success in providing the most reliable generators possible.Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac Force engine lineup offers added peace of mind and reliability for when you need it models. It provides optimized FAST RESPONSE to changing load conditions and the most.The G-Force series engines are purpose built and designed to handle the MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the rigors of extended run times in high temperatures and extreme operating conditions. surge loads to the engine.Digital voltage regulation at±1%. O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O • SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit, from the engine to the allows confident operation of sensitive electronic equipment and micro-chip based smallest electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA M61-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK"' WI-FI CONNECTIVITY: FREE with select Guardian Series home standby generators, Mobile Link Wi-Fi allows users to monitor the status of the generator from anywhere in the world using a smanphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. PROMISE ® � � GENERAC® 10/13/16 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency,Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinderwalls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum-flexibility, • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution— Controls • AUTO/MANUAUOFF illuminated buttons Select the operating mode and provide easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences, • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65°%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer, • Engine warm-up Verifies engine is ready to assume the load.Setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown.Setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries, • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability, • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC® 10 13/16 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI 221.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Ability to view generator status Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC" 10/13/16 kW Specifications Generator Model G007171-0,6007172.0 13007173-0,G00717", G007176.0,G007177-0, (10 kW) G007175.0(13 kW) 6007170.0(16 kW) Rated maximum continuous power capacity(LP) 10,000 Watts* 13,000 Watts* 16,000 Watts' Rated maximum continuous power capacity,(NG) 9,000 Watts* 13,000 Watts* 16,000 Watts* Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 41.7/37.5 54.2/54.2 66.7/66.7 Total-Harmonic Distortion Less than 5% r ' Main line circuit breaker 45 Amp 60 Amp 70 Amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit weight(lb/kg) 338/153 385/175 420/191 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load** 61 65 65 Sound output in dB(A)at 231t(7 m)with generator in Quiet-Test"'low-speed exercise mode** 57 55 55 Exercise duration 5 min Engine Engine type GENERAC G-Force 400 Series GENERAC G-Force 800 Series Number of cylinders 1 2 Displacement 460 cc 816 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Lifter type Solid Hydraulic Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VAC Oil capacity including filter Approx.1.1 qt/1.0 L Approx.2.2 qt/2.1 L Operating rpm 3,600 Fuel consumption Natural Gas ft3Mr(m3/hr) i 1/2 Load 101(2.86) 154(4.36) 182(5.15) Full Load 127(3.60) 225(6.37) 245(6.94) Liquid Propane fta/hr(gal/hr)[L/hr] 1/2 Load 36(0.97)[3.66] 56(1.54)[5.831 62(1.70)[6.45] Full Load 54(1.48)[5.62] 90(2.45)[9.28] 109(2.99)[11.32] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7.0 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multi I ft3/hr x 2,500 LP)or ftaPor x 1,000(NG).For Mega]oule content,multiply m3/hr x 93.15 LP or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-Weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Rur/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility voltage loss/Retum to utility adjustable(brownout setting) From 140-171 V/190-216 V Future set capable exerciser/Exercise set error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 sec rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stopper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaulUlncorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard **Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU(Megajoule)content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level;and also will decrease approximately 1%for each 6°C(10°F)above 16°C(60 OF). J GENERACa 10/13/16 kW Switch Options Limited Circuits Switch Features Model G007172-0 G007174-0 G007177-0 (10 kW) (13 kW) (16 I(W) • 16 space,24 circuit.Breakers not included. No.of poles 2 • Electrically operated,mechanically-held contacts for fast,positive connections. Current rating(amps) 100 • Rated for all classes of load,1100%equipment rated,both inductive and Voltage rating(VAC) 120/240,10 resistive. Utility voltage monitor(fixed)' • 2-pole,250 VAC contactors. -Pick-up 80% • 30 millisecond transfer time. -Dropout 65% • Dual coil design. Return to utility' Approx.15 sec • Rated for both copper and aluminum conductors. Exercises bi-weekly for Standard • Main contacts are silver plated or silver alloy to resist welding and sticking. 5 minutes' • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor ETL or UL Listed Standard mounting flexibility. Total circuits available 24 • Multi listed for use with 1 in standard,tandem,GFCI,and AFCI breakers from Tandem breaker capabilities 8 tandems Siemens,Murray,Eaton,and Square D for the most flexible and cost effective install. Circuit breaker protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts Dimensions *Function of Evolution controller Exercise can W set to weekly or monthly Height Width Depth Wt H1 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 cm 67.94 76.43 26.67 34.18 17.54 Wire Ranges Hz Ht Conductor Lug Neutral Lug Ground Lug 210-#14 2/0-#14 2/0-#14 DEPTH I Wz Service Sated Smart Switch Features Model G007175-0 G007178-0 • Includes Smart A/C Management(SACM)module standard. (13 kw) (16 kW) • Intelligently manages up to four air conditioner loads with no additional No.of poles 2 hardware. Current rating(amps) 200 • Up to eight large(240 VAC)loads can be managed with Smart Management Voltage rating(VAC) 120/240,10 Modules(SMMs). Utility voltage monitor(fixed)' • Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80% • Rated for all classes of load,100%equipment rated,both inductive and -Dropout 65% resistive. Return to utility" 15 sec • 2-pole,250 VAC contactors. Exercises bi-weekly for 5 minutes' Standard • Service equipment rated,dual coil design. ETL or UL Listed Standard • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 311 • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor Lug range 250 MCM-#6 mounting flexibility. *Function of Evolution Controller Dimensions Exercise can be set to weekly or monthly -W, 200 Amps 120/240,ie Open Transition Service Rated H1 Height H2 Wi Width W2 Depth in 26.75 30.1 10.5 13.5 6.3 cm 1 67,94 76.45 26.67 34.3 16.01 H2 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400 MCM-#4 350 MCM-#6 2/0-#14 DEPTH L--W2 I GENERAC* Maommoom 10/13/16.kW Available Accessories Model# Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact®). G007101-0 Battery Pad Warmer The pad warmer rests under the battery.Recommended for use if the temperature regularly falls below 0°F(-18 °C).(Not necessary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below 0°F(-18 °C)• G007103-1 Breather Warmer The breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you Contact Kit may not need.Not compatible with 50 amp pre-wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a sleek, G007027-0-Bisque Fascia Base Wrap Kit contoured appearance as well as offering protection from rodents and insects by covering the lifting holes lo- cated in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion.The paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006482-0-1 0 kW Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance 6007216-0—13/16 kW Scheduled Maintenance Kit on a Generac automatic standby generator(oil not included). The*Fi enabled LP fuel[eve(monitor provides constant monitoring of the connected LP fuel tank.Monitoring G007005-0• Wi-F[LP Fuel Level Monitor the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Status alerts are available through a free4pplication to notify users when the LP tank is in need of a refill. G007000-0(50 amps) Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages G007006-0(100 amps) Smart Management Module large electrical loads upon startup and sheds them tb aid in recovery when overloaded.In many cases,using SMM's can reduce the overall size and cost of the system. The Mobile Link 413 LTE Cellular Accessory allows users to monitor the status of the generator from anywhere G007169-0 Mobile Link'"4G LTE Cellular in the world,using a smartphone,tablet,or PC.Easily access information such as the current operating status Accessory and maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. Dimensions & UPCs 637.6mm Model UPC [25.1 in] G007171-0 696471074680 G007172-0 -696471074673 G007173-0 696471076400 7272mm [26.61n] G007174-0 696471077100 G007175-0 696471077117 °G007176-0 696471076417 e 1[4281.86 minm] ° G007177-0 696471077124 648 mm 1232 G007178-0 696471077131 [25.5In] [48.5 Inj LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2019 Generac Power Systems,Inc.All rights reserved.AI]specillcatlons are subject to change without notice. Part No.10000033190 Rev.A 07/26/19 COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES APPROVED AS NOTED AS REQUIRED AND CONDITIONS OF SOLM OIDTOYM DA B.P# S� SOUiHOlDWXPLANNlNGBOARD 5. bo gY SOLOOLOTOWNT USTEES FE a NXI DEC NOTIFY BUILDING DEPARTMENT AT SOUNLDHK 631-765-1802 8AM TO 4PM FOR THE SCHD FOLLOWING INSPECTIONS: FOUNDATION-TWO REQUIRED FOR POURED CONCRETE ROUGH-FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS ELECTRICAL INSPECTION REQUIRED y GENERAC® 16 GUARDIAN° SERIESac 10/13/ kW Residential Standby Generators Air-Cooled Gas Engine r , INCLUDES: Standby Power Rating GG07171-0,G007172-0(Aluminum-Bisque)—10 kW 60 Hz .• True Power' Electrical Technology G007173-0.G007174-0,G007175-0(Aluminum-Bisque)—13 kW 60 Hz 0007176-0,.G007177-0,G007178-0(Aluminum-Bisque)—16 kW 60 Hz • Two-lirie multilingual digital LCD Evolution"" controller t (English/Spanish/French/Portuguese) • Two transfer switch options available: 100 amp 16 circuit switch or 200 amp service rated smart switch • Electronic governor Standard Wi-Fi'" connectivitys ; System status&maintenance interval LED indicators • Sound attenuated enclosure GENERAC Flexible fuel line connector • Natural gas or LP gas operation ' { • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a ONusor C ST us n/ JI �structure.* LISTED t][V *Must be located away from doors, windows,and fresh air Note:CETL or CUL certific Lion only applies to unbundled units and units packaged with limited intakes and in accordance with local codes. circuit switches.Units pac9ged with the Smart Switch are ETL or UL certified in the USA only. https.,Ilassets.swri.org///bratyIDirectotyOfListedProducts/ Constructionindustry/973_DoC_204_13204-01-01_Rev9.pdf FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This Generac's success in providing the most reliable generators possible.Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac Force engine lineup offers added peace of mind and reliability for when you need it models. It provides optimized FAST RESPONSE to changing load conditions and the most,The G-Force series engines are purpose built and designed to handle the MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the rigors of extended run times in high temperatures and extreme operating conditions. - surge loads to the engine.Digital voltage regulation at'*1%. O_ TRUE POWER—ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit, from the engine to the allows confident operation of sensitive electronic equipment and micro-chip based smallest electronic component, appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK'" WI-FI CONNECTIVITY: FREE with select Guardian Series home standby generators, Mobile Link Wi-Fi allows users to monitor the status of the generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. GENERAC PROMISE : �� GENERAC® MMUNIEW 10/13/16 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinderwalls y Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±t%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum-flexibility, • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution'" Controls • AUTO/MANUAUOFF illuminated buttons Select the operating mode and provide easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer, • Engine warm-up Verifies engine is ready to assume the load.Setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown.Setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC' 10/13/16 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping, • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. i Connectivity • Ability to view generator status Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. G E ICI ERAC" 10/13/16 kW Specifications Generator Model G007171-0,0007172.0 6007173-0,G007174-0, G007176-0,G007177-0, CD (10 kW) G007175.0(13 kW) 0007178.0(16 kW) Rated maximum continuous power capacity(LP) 10,000 Watts" 13,000 Watts" 16,000 Watts" Rated maximum continuous power capacity,(NG) 9,000 Watts" 13,000 Watts" 16,000 Watts" Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 41.7/37.5 54.2/54.2 66.7/66.7 Total Harmonic Distortion Less than 5`90 of ' Main line circuit breaker 45 Amp 60 Amp 70 Amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit weight(lb/kg) 338/153 385/175 420/191 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 R(7 m)with generator operating at normal load'" 61 65 65 Sound output in dB(A)at 23 If(7 m)with generator in Quiet-Test"low-speed exercise mode'" 57 55 55 Exercise duration 5 min Engine Engine type GENERAC G-farce 400 Series GENERAC G-Force 800 Series Number of cylinders 1 2 Displacement 460 cc 816 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Litter type Solid Hydraulic Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity Including filter Approx.1.1 qt/1.0 L _ Apgox.2.2 of 2.1 L Operating rpm 3,600 'Fuel consumption Natural Gas ft3/hr(m3/hr) 1/2 Load 101(2.86) 154(4.36) 182(5.15) Full Load 127(3.60) 225(6.37) 245(6.94) Liquid Propane tt3/hr(gal/hr)[L/hr] 1/2 Load 36(0.97)[3.66] 56(1.54)[5.83] 62(1.70)[6.45] Full Load 54(1.48)[5.62] 90(2.45)[9.28] — 109(2.99)[11.32] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7.0 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply ft3/hr x 2,500(LP)or 1`13/hr x 1,000(NG).For Megajoule content,multiply m3/hr x 93.15(0 or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-Weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.It utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility voltage loss/Retum to utility adjustable(brownout setting) From 140-171 V/190-216 V Future set capable exerciser/Exercise set error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 sec rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaultAncorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard **Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).`Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU(Megajoule)content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 tt(304.8 m)above sea level:and also will decrease approximately 1%for each 6°C(10'F)above 16°C(60°F). GENERAL" 10/13/16 kW Switch Options Limited Circuits Switch Features Model G007172-0 G007174-0 0007177-0 (10 kW) (13 kW) (16 kW) • 16 space,24 circuit.Breakers not included. No.of poles 2 • Electrically operated,mechanically-held contacts for fast,positive connections. Current rating(amps) 100 • Rated for all classes of load,100%equipment rated,both inductive and Voltage rating(VAC) 120/240,10 resistive. Utility voltage monitor(fixed)' • 2-pole,250 VAC contactors. -Pick-up 80% • 30 millisecond transfer time. -Dropout 65% ' • Dual coil design. Return to utility* Approx.15 sec • Rated for both copper and aluminum conductors. Exercises bi-weekly for Standard • Main contacts are silver plated or silver alloy to resist welding and sticking. 5 minutes" • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor ETL or UL Listed Standard mounting flexibility. Total circuits available 24 • Multi listed for use with 1 in standard,tandem,GFCI,and AFCI breakers from Tandem breaker capabilities 8 tandems Siemens,Murray,Eaton,and Square D for the most flexible and cost effective install. Circuit breaker protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts Dimensions *Function of Evolution controller Exercise can be set to weekly or monthly Height Width Depth —W1 H1 H2 W1 W2 inE67E.94 75 S76.43 10.5 13.5 6.91 cm 26.67 34.18 17.54 Wire Ranges H2 Hi Conductor Lug Neutral Lug Ground Lug 2/0-#14 2/0-#14 2/0-#14 DEPTH I W2--I Service Rated Smart Switch Features Model G007175-0 G007178-0 • Includes Smart A/C Management(SACM)module standard. (13 km) (16 kW) • Intelligently manages up to four air conditioner loads with no additional No.of poles 2 hardware. Current rating(amps) 200 • Up to eight large(240 VAC)loads can be managed with Smart Management Voltage rating(VAC) 120/240,10 Modules(SMMs). Utility voltage monitor(fixed)` • Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80% • Rated for all classes of load,100%equipment rated,both inductive and -Dropout 65% resistive. Return to utility* 15 sec • 2-pole,250 VAC contactors. Exercises bi-weekly for 5 minutes* Standard • Service equipment rated,dual coil design. EiL or UL Listed Standard • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Lug range 250 MCM-#6 mounting flexibility. *Function of Evolution Controller Dimensions Exercise can be set to weekly or monthly -Wt 200 Amps 120/240,1 a Open Transition Service Rated H1 Height H2 W1 Width W2 Depth in 26.75 30.1 10.5 13.5 6.3 cm 67.94 76.45 26.67 34.3 16.01 H2 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400 MCM-#4 350 MCM-#6 210-#14 DEPTH I—W2-� GENERAC® m 10/13/16 kW Available Accessories Mode!# Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact ). G007101-0 Battery Pad Warmer The pad warmer rests under the battery.Recommended for use if the temperature regularly falls below 0 IF(-18 °C).(Not necessary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below 0 IF(-18 °C) G007103-1 Breather Warmer The breather warmer is for use In extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you Contact Kit may not need.Not compatible with 50 amp pre-wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a sleek, G007027-0-Bisque Fascia Base Wrap Kit contoured appearance as well as offering protection from rodents and insects by covering the lifting holes lo- cated in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to,protect from future corrosion.The paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006482-0—1 0 kW Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance G007216-0—13/16 kW Scheduled Maintenance Kit on a Generac automatic standby generator(oil not included). The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring G007005-0 WI-Fi LP Fuel Level Monitor the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Status alerts are available through a free4pplication to notify users when the LP tank is in need of a refill. G007000-0(50 amps) Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages G007006-0(100 amps) Smart Management Module large electrical loads upon startup and sheds them tb aid in recovery when overloaded.In many cases,using SMM's can reduce the overall size and cost of the system. The Mobile Link 46 LTE Cellular Accessory allows users to monitor the status of the generator from anywhere G007169-0 Mobile Link"413 LTE Cellular in the world,using a smartphone,tablet,or PC.Easily access information such as the current operating status Accessory and maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. Dimensions & UPCs 7278 mm 637.E mm- r4eA In] Model UPC 125.1 In, G007171-0 696471074680 G007172-0 696471074673 G007173-0 696471076400 727,2mm 12e.6 In] G007174-0 -696471077100 G007175-0 696471077117 G007176-0, 696471076417 o 0 0007177-0 696471077124 84e mm 7232 mm rG—O07178-0 696471077131 (25.5in] [48.6In, LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GE N E RACO Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2019 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Part No.10000033190 Rev.A 07/26/19