Loading...
HomeMy WebLinkAbout50011-Z �o�Og�EFOI,f�oGy Town of Southold 2/10/2024 a P.O.Box 1179 vol 53095 Main Rd Gy?jOl '1,ao�Yr � Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44962 Date: 2/10/2024 THIS CERTIFIES that the building GENERATOR Location of Property: 4205 Breakwater Rd,Mattituck SCTM#: 473889 Sec/Block/Lot: 106.-3-6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/24/2023 pursuant to which Building Permit No. 50011 dated 11/9/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: 1 accessory generator as applied for. The certificate is issued to Thornton D&J Family Trust of the aforesaid building. 1 SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50011 1/22/2024 PLUMBERS CERTIFICATION DATED th i d Signature SUFFot,r� TOWN OF SOUTHOLD BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50011 Date: 11/9/2023 Permission is hereby granted to: ,Thornton D & J Family Trust 4205 Breakwater Rd Mattituck, NY 11952 To: Install an accessory 26kW generator to an existing single-family dwelling as applied for per manufacturers specifications. At premises located at: 4205 Breakwater Rd, Mattituck SCTM # 473889 Sec/Block/Lot# 106.-3-6 Pursuant to application dated 10/24/2023 and approved by the Building Inspector. To expire on 5/10/2025. Fees: ACCESSORY $125.00 CO-RESIDENTIAL $100.00 ELECTRIC $100.00 Total: $325.00 Building Inspector *pE SOUjyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �. �Q sean.devlinO-town.southold.nv.us Southold,NY 1 1 97 1-0959 Q COUM(`I BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Thorton D & J Family Trust Address: 4205 Breakwater Rd city:Mattituck st: NY zip: 11952 Building Permit#: 50011 section: 106 Block: 3 Lot: 6 WAS EXAMINED AND FOUND TO BE.IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Peconic Power Systems License No: 45056ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X . 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo'Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures 11 Sump Pump Other Equipment: 26kW Generac Generator w/ 200A Whole House Transfer Switch Notes: Generator Inspector Signature: Date: January 22, 2024 S.Devlin-Cent Electrical Compliance Form v SOUlyO6 # # TOWN OF SOUTHOLD BUILDING DEPT. comm, 631-765-1802 � o INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: q_46 cz GA� DATE I I-)O?mINSPECTOR �o��DE SOUjy�� V — f # # TOWN OF SOUTHOLD BUILDING DEPT. °ycourm��` 631-765-1802 ' INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE li�Ii INSPECTOR ` MELD INSPECTION REPORT DATE COMMENTS V ro FOUNDATION (IST) -------------------------------- FOUNDATION (2ND) z 0 H O ROUGH FRAMING& PLUMBING r r INSULATION PER N.Y. STATE ENERGY CODE � r � FIN ADDITIONAL COMMENTS \eC�ri C CE,� Po z �X H V1I z x d ro TOWN OF SOUTHOLD—BUILDING DEPARTMENT w Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtom=.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only 4 1�� :J 17KF�13 i I j PERMIT NO._5�O 1 I Building Inspector: OCT 2 4 2023 Applications,and forms must be filled out in their entirety.Incomplete applications will not be accepted.,Where the Applicant is'not the owner,an ; B ,DjO DEPT, Owner's Authorization form.(Page 2)shall be completed. TO yrN C r11UTNa,fr L.0, Date: 101�0132-3 OWNER(S)OF PROPERTY: Name: �o^ SCTM#1000- Project Address: �ao..rl Phone#: (;Da Vas _ 06q y Email: A+korn�on Ca CoK, n-e- Mailing Address: CONTACT PERSON: ` Name: � �� Mailing Address: PO 60>< S 61 Phone#: 631- 73'-1—Sea& Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: 'e-CCYIc oc...,i Mailing Address f3ox Phone#: 6 3/_ 3_1-/— Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: R6ther akkc„ 6y..-e.rr.e— $ /3, 6 Will the lot be re-graded? ❑Yes Q b Will excess fill be removed from premises? ❑Yes o 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes 4�TNo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with,all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 220.45 of the New York State Penal Law. Application Submitted By(print name): �o / 5��,��� uthorized Agent ❑Owner Signature of Applicant: Date: �ola3 l a� STATE OF NEW YORK) SS: COUNTY OF St ;'& ) po"(� S�rM2v�y� being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Con -rc Cc " r (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of �L� ,20 a 3 E- WViV.-1- Notary Public Thomu NOTARY?UB1,LC,STATE OF N 8 W Y-JR:- RegistsatlonNo.OITH615682 ROPERTY OWNER AUTHORIZATION Qualified in Suffolk County (Where the applicant is not the owner) Co^�inission Expires 1Deccm�4,20 i I, �CA,vL l�.� �-o r'- residing at Ly� do hereby authorize �a ¢��- .S�-av��.,.� to apply on my behalf to the T of S told Buil ng Department for approval as described herein. O ]o1a0l -3 Owner's Signat� Date V d zk2AY� Print O ner's Name 2 �o��g�fFOL,��oGy BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD co $ Town Hall Annex- 54375 Main Road ' PO Box 1179 w • , Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 iamesh(@-southoldtownny.gov— seand(ab-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ail Information Required) Date: 10/23/23 Company Name: Peconic Power Systems Electrician's Name: Robert Stanevich License No.: ME-45056 Elec. email:Peconicpowersys@gmail.com Elec. Phone No: 631-734-5026 01 request an email copy of Certificate of Compliance Elec. Address.: PO BOX 512 Cutchogue NY 11935 JOB SITE INFORMATION (All Information Required) Name: David Thorton Address: 4205 Breakwater Rd Cross Street: East rd Phone No.: 602-828-0694 Bldg.Permit#: soo Il email: Tax Map District: 1000 Section: I d Block: Lot: (p BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): New 26KW Generac generator with 200 amp service rated transfer switch S uare Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑✓ NO [--]Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# []New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect Flu nderground❑Overhead #Underground Laterals 1 R2 M H Frame Pole Work done on Service? n Y ON Additional Information: PAYMENT DUE WITH APPLICATION P' APPROVED AS NOTED DATE: B.P.# 5 O O I FEE a a-BY COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES NOTIFY BUILDING DEPARTMENT AT AS REQUIRED AND CONDITIONS OF 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: FOUNDATION-TWO REQUIRED 8OUiNOLta=Pl=G90ARD FOR POURED CONCRETEMTB ROUGH-FRAMING&PLUMBING tyl Dm INSULATION wIv FINAL-CONSTRUCTION MUST OD BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS ELECTRICAL INSPECTION REQUIRED L,J V) - a o oo TR.. ER �A.BREAKS ' - �,. 1. ° L j(LUTHER'S ROAD) .. "` _ . . . _ Qf _t. ° EDGE 0IP PAVEMENT fl MAIL aox S 0 6°ZO'00" E a • Zo' •• -- - - - - O~ a- b CS � v IN3 3"-• � .. � •O� - a ,� - Q •� - co Lir a� � to h U 44''-' - U N •"Q XLL m, Xzj • lV _ p N ~ O 3' 30dab0 j 3SIn0H ANOIS Ln O y o .6•lZ ��J o•- • am N L"- • ``O�, � ilOt .0'lZ d.8'9 °�•� .O�S£—'—__ a -_"�_ �t -ry •Y'- �.73� WQ N 1� C •=': O a U ovi d31S QOOM a> t 3 �00 4 W.>�• 3$O O �i 3 W W W QIL G N - ZO W W O W C �cn 4 •�T GENERAC� GUARDIAN® SERIES Residential Standby Generators Air-Cooled Gas Engine Standby Power Rating INCLUDES: G007290-0,G007291-0(Aluminum-Bisque)-26 kW 60 Hz • True Power-Electrical Technology • Two-line multilingual digital LCD Evolution'controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available ! Electronic governor • Standard Wi-Fi®connectivity • System status&maintenance interval LED indicators ;• `~ ;. • Sound attenuated enclosure � • • Flexible fuel line connector ` • Natural gas or LP gas operation -_ IGEN • 5 Year limited warranty • Base fascia r ) • Listed and labeled for installation as close as 18 in(457 mm)to a ' structure.' 'Must be located away from doors,windows,and fresh air intakes and in or C @us accordance with local codes. c0% . LISTED Note:CEfL or CUL certification only apppl les to unbundled units and units packaged with limited circuit switches.Units paZged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN& RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. ' loads to the engine.Digital voltage regulation at±1%. O TRUE POWER'"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how forthe entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA M01-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence Is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby generators,Mobile Link Wi-Fl allows users to monitor generator status from any- where in the world using a smanphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. PROMISE GENERAC® 26 kW Features and Benefits Engine • Generac G-Farce design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine of life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution— Controls • AUTO/MANUAUOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons . Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home, • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. M GENERACO 26 kW Features and Benefits Installation System • 14 in(35,6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Vile-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. Y �l GENERAC® 26 kW Specifications Generator Model G007290-0 G007291-0 (26 kW) Rated maximum continuous power capacity(LP) 26,000 Watts* Rated maximum continuous power capacity(NG) 22,560 Watts' Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 108.3/93,8 ' Total Harmonic Distortion Less than 5% Main line circuit breaker 110 amp Phase 1 Number of rotor poles 2 Rated AUrequency 60 Hz Power factor 1.0 Battery.requirement(not Included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) 518/235 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63,5 x73.7 Sound output in dB(A)at 23 0(7 m)with generator operating at normal load** 67 Sound output in dB(A)at 23 It(7 m)with generator in Quiet-Test'"low-speed exercise mode'* 57 Exercise duration 5 min Engine Engine type GENERAC G-Farce 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast Iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx.1.9 qt/1.8 L Operating rpm 3,600 Fuel consumption Natural gas fl3/hr 03/hr) 1/2 Load 188(5.32) Full Load 333(9.43) Liquid propane 113/hr(gal/hr)Mr] 1/2 Load 75(2.06),[7.78] Full Load 132(3.63)[13.731 Note:Fuel pipe must he sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas. For BTU content,multiply ON x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode,buttons:AUTO Automatic start on utility.failure.Weekly,Bi-weekly,or Monthly selectable exerciser, MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) U01ityVoltage Loss/Return to Utility adjustable(brownout setting) From 140471 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/Alarrrt/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Faull/Missing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Probfem:Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring protection Standard Common external fault capability Standard Feld upgradable firmware Standard Rating definitions—Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. No overload capability is available for this rating.(Alf ratings in accordance with BS5514,IS03046,UL2200,and DIN6271).Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 It(304.8 m)above sea level and approximately 1% for each 10°F(6'C)above 60°F(16'C)."Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. U.S.EPA certified for non-emergency applications. GENERAC® 26 kW Switch Options Service Rated Automatic Transfer Switch Features model G007291.0(26 W) • Intelligently manages up to four air conditioner loads with no additional hardware. No.of poles 'Y Current rating(amps) 200 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Voltage rating(VAC)' '120/24Q 10- with Smart Management Modules(SMMs). Utility voltage monitor(fixed) • Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up e0% -Dropout 65% • Main breakers are rated for 80%continuous load. Return to utility". Appl ox 13 sec • 2-pole,250 VAC contactors. ETL or UL listed Standard • Service equipment rated,dual coil design. Enclosure type NEMA/UL 3R • Rated for both aluminum and copper conductors. Circuit breaker protected 22,000 Lug range _ ., .250 MCM:#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Funcflon of Evolution controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bi-weekly,or monthly w+ Dimensions 200 Amps 120/240,is Open Transition Service Rated Heigh Width Depth Hi H2 W1' W2 Hz H+ in 26.8 1 30.1 10.5 13.5 6.9 cm 67.95 J 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug .Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 210-#14 DEKH I-w2- GENERAC® 26 kW Available Accessories Model# Product Description G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°Cj.(Not nec- essary for use with AGM-style batteries). Z0710P-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy Icing occurs. :G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque 'Fascia Base Wrap Kit ..The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or darnaged,'it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007009-0 LTE LP Tank Fuel Level The LTE enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank Monitoring the LP Monitor tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Status 'alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. 6007169-0-4G LTE Mobile Link'Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-WI-FI/ Accessories a smart phone,tablet,or PC.Easily access Information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and Insects by covering the lifting holes'located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. . G007301-0 High Altitude Kit A high altitude kit may be required when operating over 2,000 it(610 m)above sea level per U.S.EPA regulations.Op- erating the engine with the incorrect engine configuration at a given altitude may increase emissions and decrease fuel efficiency and performance. 1 Dimensions !& PCs Model UPC 637.0 mm 1218 mm [25.1 In] [48 .e ln] G007290-0 696471087307 G007291-0 696471087314 1 727.2 mm r28.61n] 1 I I O oil 848 mm 1232.. [25.5 in] [4e.5lnl LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for elect dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. •S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A000202 i 94 Rev.D 09/19/2022 i