Loading...
HomeMy WebLinkAbout50162-Z �O�gufFOt,��OG Town of Southold 2/12/2024 y� P.O.Box 1179 C. W 53095 Main Rd o4i o�� Southold,New York 11971 �41 � �a . CERTIFICATE OF OCCUPANCY No: 44985 Date: 2/10/2024 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 1875 Cedar Dr, Southold SCTM#: 473889 Sec/Block/Lot: 77.-1-27 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/27/2023 pursuant to which Building Permit No. 50162 dated 12/27/2023 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"additions and alterations, including deck,windows and electric for attached lean-to shed,to existing single family dwelling as applied for. The certificate is issued to Citera,Jeffrey&Angela of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50162 2/8/2024 PLUMBERS CERTIFICATION DATED 0 tho ize Si nature �o�osuFFot,��o TOWN OF SOUTHOLD a BUILDING DEPARTMENT . y� TOWN CLERK'S OFFICE VJ 2 o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit* 50162 Date: 12/27/2023 Permission is hereby granted to: Citera, Jeffrey 55 Gagens Landing Rd Southold, NY 11971 To: Legalize "as built" deck and remove plumbing to shed and legalize existing electric to shed as applied for. Work includes replacement windows in-kind. At premises located at: 1875 Cedar Dr, Southold SCTM #473889 Sec/Block/Lot# 77.-1-27 Pursuant to application dated 11/27/2023 and approved by the Building Inspector. To expire on 6/27/2025. Fees: AS-BUILT FEE $794.00 CO-ADDITION TO DWELLING $100.00 ELECTRIC $200.00 Total: $1,094.00 JAB Building Inspector �pF SO(/l�,Ql Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q -�, �. �o sean.devlin(�-town.southold.ny.us Southold,NY 11971-0959 Q BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Jeffrey Citera Address: 1875 Cedar Dr city:Southold st: NY zip: 11971 Building Permit#: 50162 Section: 77 Block: 1 Lot: 27 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 2'LED 1 Exit Fixtures Sump Pump 11 Other Equipment: Old 30A Dryer Feed Has Been Disconnected in Panel Notes: " AS BUILT NO VISUAL DEFECTS " Attached Shed Wiring Inspector Signature: '- Date: February 8, 2024 S. Devlin-Cert Electrical Compliance Form OE so # # TOWN O SOUTHOLD BUILDING DEPT. °`ycoutm��' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: LO- 1 Veil 1 Qt 4 UAr le el— DATE INSPECTOR so # # TOWN OF SOUTHOLD BUILDING DEPT. coum, 631-765-1802 INSPECTION , [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O [ ] RENTAL REMARKS: Q' Po r IS QA v) ail u�-OJ'/ az<4 2 DATE S INSPECTOR aIE SOUIy�� - * # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] OULATIOWCAULKING [ - ] FRAMING /STRAPPING [U61NAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT.CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ohmovffl-, otmkkko �^- 1� (,fiodc i►G�/ nn II T orw lb k-.001 coh c �— DATE 1 y INSPECTOR Tiderunner Engineering & Design, P. [ Y L F EB - 7 2024 7 Ridgewood St Bay Shore, NY 11706 (631.)-839-4824 August 21, 2023 Building Inspector Town of Southold 53095 Main Road Southold,NY 11751 Re: Construction Certification Citera Residence 1875 Cedar Drive Southold,New York Dear Sir or Madam: I have visited the site and reviewed the work and the construction documents for the deck installation and can certify that the concrete post footings have been installed in accordance with the approved plans and the 2020 NYS Residential Building Code. If you have questions please feel free to call Sincerely, P�SOF NE SCHWW'0� Louis Schwartz,P.E. F 77006 �pR�FESSIONP��• • 1 r i • h 9p OK`x(�S'. �: _ - :f:. . �� t �..,. .w. - y--.�..►���� .'^^M� 1 i %off 1� r lb 1 • V, ■�■� i t 4 E w:ice. •Y rM J:. t t t 'F � _--,�-" �y l;r +�~ ,` - �� .� w �� � �` w f" i f � ��' "� _� +►- E s,:�! i v� MELD INSPECTION REPORT DATE COMMENTS - O t� FOUNDATION (IST) - - - ------------------------------------ -- a[ FOUNDATION (2ND) O t� H VI ROUGH FRAMING& PLUMBING INSULATION PER N.Y. Q "� STATE ENERGY CODE S t Wak.0000v Olot —L S - I FINAL Lu ADDITIONAL COMMENTS Z m - YY et .�z x b a TOWN OF SOUTHOLD—BUILDING DEPARTMENT, N z Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 • °tea Telephone(631) 765-1802, Fax(631) 765-9502 https://www.southoldtownnygov V, Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only �u'! PERMIT NO. Building Inspector: �} 1, NOV 2 7 2023 Applications and formsjmwst be filled out in their entirety:Incomplete F applications wilt"not be accepted ?Where the Applicant i§not the owner,an Building Department Owner's authorization form,(Page 2)shall be completed Tbv�n of Eouthold Date:11.20.23 z OWNER(5)OF PROPERTY Y Name: J E I. SUM#1000-77A-27 Project.Address: • 5- . E (S.. R U IF, c50. Phone#: Email: Vrct ep Mailing Address: $-$ CT -ems 14kN pt1V6: /.,p, sOf',J CONTACT,PERSON `' w r- _ ' Name:Joan Chambers Mailing Address:PO BOX 49 Southold NY Phone#:631-294-4241 FMTII.joanchambersl 0@gmaii.com :'DESIGN PROFESSION/►)INFORMATION Name:Lou Schwartz Mailing Address: 7 Ridgewood St, Bay Shore, NY 11706 Rhone#: (631) 410-6838 TEmail:tiderunnerengpgpielil.com ,CONTRACTOR INFORMATION Name:as-built Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other as-built deck And i2luffbw and eleHvi& $ Will the lot be re-graded? ❑Yes NNo Will excess fill be removed from premises? []Yes NNo 1 f PROPERTY INFORMATION Existing use of property:Residential Intended use of property:Same Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_40 this property? 0Yes®No IF YES,PROVIDE A COPY. The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the.Town Code.APPUCATION Is HEREBY MADE to the Building Department for the_Lasuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,Newyork and other applicabletaws,Ordinances or Regulations,for the construction of buildingss, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing•code and regulations and to admit authorized inspectors on premises and In building(s)for necessary Inspections.false statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name):Joan Chambers ®Authorized Agent Downer Signature of Applicant: CO N N I E D.BUNCH Date: Notary Public,State of New York No. 01BU6185050 STATE OF NEW YORK Qualified in Suffolk County SS: �/ Commisslon Expires April 14,2 Q. / _ , COUNTY OF ) Joan Chambers being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ` ` a ay of .20 a� rv`� , Notary Public $�1 � '"�,{` `(,}A`�'�.d1� A '^';t�'6'�~S`e9%KP"'�4Skl'ru C'n v a• e0 A , i -L 6��Y�r t `4 r (Where the applicant is not the owner) �- residing at do hereby authorize Joni Q!b5; 'Y OLE to apply on my behal a of Southold Building Department for approval as described herein. w er' gnature „ Date Print Owner's Name } 2 aguFFat - BUILDING DEPARTMENT-Electrical Inspector oab�' TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 � Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 lamesh(cr7southoldtownny qov-- seand(cDsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION AlI Information Re wired Date: 1.26,23 Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: rr- C L-m�A Address: ZS' Ceba-& vi kolua 60Ur+to+-e Cross Street: kyem v Phone No.: r Bldg.Permit#: rj ' to �_ email: Tax Map District: 1-000 Section: 7 Block: ! Lot: 2'] BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: T �5!s Circle All That Apply: Is job ready for inspection?: YES ❑NO ❑Rough In 0 Final Do you need a Temp Certificate?: ❑ YES YNO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 F1 H Frame M Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION' PERMIT 9 Address" Svvitche's Outlets 1 GFI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven �� ?��� �Irnokes DW Mini -arbon Micro Generator =ombo Cooktop Transfer aC AH Hood Service Amps Have Usec -pecial- :omments } �wr�wECCING � �J �F `' SURVEY OF PROPERTY tii P AT SOUTH OLD o� off, TOWN OF SOUTH OLD SUFFOLK COUNTY NEW YORK 1000-77-01 -27 F� S CALE: 1 =2 0 MAY 9, 2023 so AUGUST 8, 2023 ( REVISIONS) Z / O 4 � a / Jv \ ] \ pUBC IC eL<ING � / 9TF`,p o Pep 4 30'E \ q TER (o 3.7 a. 2p 7, SNFO F(� � a- 4�00 T 4 l O11F � � ��T 1 9 � �20 00, � I 5.8' �v (j Z cy)� COr 1 9g / jORQn Cy/1� v 27 A- A5Pt4,,,�7" CL EL g 8g 21 E AY ^ 54.5' o' N / 1 STORY. (o / F� 4� FR. HSE. %� CONC.BLOCK ce F. ,^ ET.WALL 40�� �SolR gRFq J �S •3 3 s1� ti��„"' `•,� OFCK dip �� �S !U �/ TEST HOLE DATA McDONALD GEOSCIENCE k / - 03/21/2023 �oT O L Gp/C,o c I / �, OT 1 EL 44.5 OA o_ 96 BROWN SILTY SAND SM C 3 v 80 PALE BROWN FINE SAND SP c / Q UTIL.POLE \� 17' NOTE. NO WA TER ENCOUNTERED WELL 150'+ CL EL AREA= 9,376 Sq.. Ft. 54.6' EL E VA TIONS REFERENCED TO NA VD '88 LOT NUMBERS REFER TO 'MAP OF GOOSE BAY ESTATES' FILED IN THE SUFF❑LK f_„ COUNTY CLERK'S OFFICE ON NOV. 13, 1934 = UTILITY POLE \ ee AS MAP NO. 1176. 0 ANY ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION ® = WELL �, =_° OF SECTION 7209 OF THE NEW UBDIV SIGN EDUCATION LA = p(/D ECCZNG N.Y.S U S. NI 05,132618 EXCEPT AS PER SECTION 7209 S CERTIFICATIONS TEST HOLE 8C1 HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF C (� PECONIC J YORS, P.C. SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR = MONUMENT q TER (631) 765 020 FAX (631) 765-1797 WHOSE SIGNATURE APPEARS HEREON. Email. peconicsurvey0opton/ine.net P.O. BOX 909 1230'TRAVELER STREET 23-013 SOUTHOLD, N.Y. 11971 e 1"ANDERSEN' 100 SERIES PRODUCT PERFORMANCE WINDOWS • DOORS About the Label About the NFRC Look for this certification label on every window and The National Fenestration Rating Council(NFRC)is a nonpartisan coalition of professionals whose purpose patio door you buy.The NFRC section was designed by is to provide fair,accurate and credible energy performance ratings for fenestration products.NFRC's the National Fenestration Rating Council to provide membership Includes manufacturers,suppliers,designers,specifiers,utility companies,government agencies accurate information that helps you promote the energy and other building Industry representatives. efficiency of the homes you build.These ratings allow you- Andersen Corporation is a founding member of the NFRC and continues to support its work by providing fair, and your customers-to measure and compare the energy accurate and credible energy performance ratings to consumers and the building industry.If you have any performance of similar products.If the product does not questions about the NFRC,its program or energy performance ratings,write them at NFRC,6305 Ivy Lane, have this label,the NFRC has not verified its claims. Suite 410,Greenbelt,MD 20770.Phone:301-589-1776.Website:nfm.org Do not remove until final code inspection.Save label for future reference. ENERGY STAR*Certified in Highlighted Regions Canal ER/RE 18 Energy Rating(ER)represents"Energy Rating" onmeY�ectrd t and Is a rating used in Canada for product cempadson.pgrposes(the higher the ER number,the more energy saved during the heating season). o-ire ormrgyateroov .•'c ENERGY STAR,Climate Zone Map is based on U-Factor and solar heat gain coefficient criteria for J�A N D E R S E N' specific ENERGY STAR climate zones within the WINDOWS • DOORS 9.11 United States and Canada.The shading of the map 100 Sodas Single Hung Window AND-N-80-o2062.00001 shows wh(ch climate zones)a particular product National FenaMlion Flbrex Composite Frame,Low-E SmartSun and glass type Is ENERGY STAR Version 7.0 Rating counnle Heatlock with Argon ProductType:Singe Hung certified in.Visit andersertwindow&comi/energystar ENERGY PERFORMANCE RATINGS for more details. U•Factor indicates how well a product U•factor A Solar Heat Gain Coefficient. prevents heat from escaping(the lower the 0.25 I 1.42 0.20 Solar Heat Gain Coef .ant measures how number,the better). (U—W) ( 9 well a product blocks heat caused by sunlight ADDITIONAL PERFORMANCE RATINGS (the lower the number,the more It will help Visible 71ransmittance refers to how much Visible Transmittance reduce the use of air conditioning and as a visible light comes through a product(the 0.48 result,reduce electrical bills and energy use). closer to1.0,the more light istransmitted). r.W.Me.ltl.walh�a.s.nb.ppma feACpne. .va.. . p�na inoldou�re�nm�ma�sa�.ap��ict�atns.e�pa�w�a.e�m - Comforo6�ur<eannoofmoNrRoA,21.�m�Mm.hM1 . ...ricer WDMA Hallmark Certifkation verifies the performance ratings of this product Dd W D MA gyp:1294W99 Hanes t:enleed Anderson Corpomtlon were tested by an independent testing ..a dmarom wosed"Seta.Harowlma. Mmufeftmrsapuglei Hamad,CeNnmaon m Indicated neba laboratory and verified by a third-party nun= certification program. AW.MkWCSe m,ltaz/auadd aeaccacv `b°iaas.ns DPI" MMVWDK4aa 10JAS2JAlldde tleselGPWa GAT.1 ,99.7,.61 Performance Grade(PG)and Test Standards tl . aastca�ro.deamm. m Design Pressure(DP)Ratings �aroMa�a+.I1Wmi Reme TN .220P.•,u0 Pa Were P.symm •aov. c miner umoaewt:,aosbn•n� R.15906 Glazing: 2.2mm AN outer/2.2mm AN Inner Glass Construction Used with t this product type. Thb pladudcal ezpwe you b chentms mdudinp trt.1 dbGdo,Mahhbp"n h me.,slaof C.W".W to—"ce cer and m.nencl,WW h I�.nam"elmhmcord,.nntodauxeamaereaa Cepledudlw - FraNm ror more lnfortre,bn l;.t pa to waw.Pebwanuyacadov Meets or exceeds CEC a IECCAlr InaemOon RecluVemont.of 0.2 CFWsgA or lower. WDMA Mailm rk CtMfloetlon Proom.Compileswnh HUD UM BuMn No.M. •NFRC ratings am based on modeling by a third-parry agency as validated by an Independent test lob In compllence with NFRC program and procedural mqulrements. •'ENERGY STAR'Is a re®stered trademark of the U.S.Emironmamal Protection Agency. 2024-25100 Series Product Guide Page 4 of 4 C F 1"ANDERSEN' 100 SERIES PRODUCT PERFORMANC WINDOWS & DOORS 7 2024 NFRC Certified Total Unit Performance FEB For current performance information,please visit niftorg. i Andersen'Product MW PerfoirmanceDuall�lpamlQaisu. r "J;d F*fOrmance Tip er 6-F.tt6n', 'VP Without 0.31 0.54 Iti'M Gd LIOL_22_8----A-L8_Q.ML 0._30 6.2-8 Simulated Divided 4gkt GqLlqs 8 0.25 �i-:M43: 0.48. Simulated Ml_q��dgq�q�Al ni�lletjGrllles 0.28 0.48 0.25 0.43, Flnelitit'Grilles,�_0.28, 101t VA FlnelightWith EderiorApplied Grilles Flnellt th ExtinlorADDIled Grilles Full Divided Ught Grilles 029, 0.25 Full Divided Light Grilles 031,.' 0.28 0.48 0.27 OA7 WithoutGrIlles 0.26, 031 Wi Wt�hul!_"411 jA 7_1 i, d Divided Ught Grilles 0*26,.' 0.28 0.47, Simulated Simulated D�d Ught Grilles 0.24 2i i FinellglitGrIlles :0.24 0.25 ,0.42 flnell;tt Grilles 0.28 0.47 nLllltLY�Lth ftetorApplIltdGA1121 _KlLth.��rLo�ApRll!d Grilles L_1 `:0.Full Divided Ught Grilles 026`. 0.25 Full Divided Ught Grilles 0.28' 0.28 0.47 2 IthoulGrilles-,".,'0.27 1- 0.18 0 _Without Gdlle.43�-- .0.29 0.21 0.49s i Simulated :0.27 ;� 0.17 039, ad Divided UjMt Grilles 029 0.19 0.43% Simulated Divided Ug1bt Grilles Finell t Grilles 0.27:", 0.17 0.39" FlneligttGrilias 1.A2 .19 1.43 • E •FlitelightWith Exterior 'r FlnellOdWith E WGrIlles FAeflarApplled Grilles .100'Sedes Full D iTed 0.17 0.39-� 100 Sodas Full Divided Ught Grilles 0.31-,,­�: 0.19 - - 1,0.43, ylfim��$t-.4 . L ­ 0;48,,catsoment Wi1ndavvi without Grilles 0.24 0.18 0,42' 'S Without Grill s 0.25 0.20 038 0.42 D� g Simulated Divided Light Grilles 0.26 0.18 Simulated Ugit Grilles 0.24,, 0.16 19 ig 4 038: Fl�eLjjt�G�rj[IaLj._�.25 0.18 0,42:.'' finellort Grilles 0.2 0.16 2.2 MM glass: 22,mm Vow i E�jelgktWiq!�� lild IIS A 025-, 0.16 0.38 0.42�0.28 0.18 Full Divided Light Grilles Full Divided LILpt Grilles Without Grilles Without Grilles '030 0.19 0.30- _2.17 --,R..26 i' _17,! Simulated Divided U@)tGdlles 0.28 0.16 -0.24 Simulated Divided�g�t Grilles 28 g.16 �-1 7 27-'- FinallghtGrill njel!AktW_nh&!tdGrApLjjed Gdlles FinellyhIMh Full Divided Ught Grilles 0.29 0.16 0.24 Full Divided ILI&Grilles 032-1, 0.17 0.27 Z' Without Grilles 0.28-,, 0.46 "0.53 7'� _Without Grilles ':0.31,,, 0.52 �0,60- 0.47' Simulated Divided U 0.47 0.53- Simulated Divided LlOt Grilles --,'0.28 0.42 q.L7 I'molOt Grilles 0.26��2 0.42Flnellglit Mies 031'" FlnelightWith EdedorApplled Grilles fr eligb�Wltb E!j�doApplled Grilles Full Divided Uglit Grilles 0.29,.: 0.42 0.47. Full Divided Ught Grilles .0 2, 0.47 0.53 Without Grilles Without Grillesrt'-0.46 0.59 '0.62' itho 0.41 0.52 7.V41 0.48 Simulated Divided Uglit Simulated Divided Uett Grllle�_ 7-_nA9 Illitt Girilles 7';.A55 FI I ght GLdllas 0.41 0.48. 0.49 f!al!;!ptWitt ExWqorAppliedGdlles tlinelttWitqB��nqrAppl.led Grilles Full Divided Light Grilles 0.47,;�"- 0.537 0.4F=OAQ,. Full Divided Ught Grilles 0.42 Without Grilles 018 i 0.28 '0.48 Without Grilles 0.30 0.31 0.54 A.W!'�' Simulated Divided )l 0.30 0.28 0.48 -6.2-8 0.25 _t GLnlles Simulated Divided Upt Grilles Ught L_ Firelight"Grilles 0.29 0.25 0.43" FlneIl0ijjGrIIIqj -0.30 0.28 0.48 lied Gdlles : --,' ,­.;, _ - - . . IneliCtEith Brl;�rtorApplied Grilles. ­_'___ 0.48 Full DIvIdea ji 0.5 jj7 o.j6 Full Divided Ugint Grilles .6 WithoutGrIlles 0.25 2.27 .47, 0.31 0 Simulated Ohdded Simulated Divided 0.28 '0.47 �a Ujt�Gril I O�26 U_�0-2_5 0.25 4-2 1 Finelight Grilles 0.25 0.25 0A2 flneliptGrilles -7026�., 0.28 0.47- W FlneliglitWlth EderhorA Iled Gillies Flnellglit ith EdericrApplle d Grilles 0.42 0.28-' 0.28 0.47 Full Divided Light Grilles 0.26- 0.25 Full Divided Lliet Grilles WithoutGrIlles 0.29- 0.21 0.49 Without Grilles 0.21,_L' _R.18 0-43 --Sim Simulated Divided Ught Grilles 0.27 0.17 039- Simulated Divided Ught Grilles• 0.29, 0.19_0.43 V Finelight Grilles O.M 0.19 0.43 Finell .0.2T 0.17 0.39: E I With ExterlarApplied Grilles d Grilles JIBS Series f:qelightWil Full Divided (717i 7 �039--_ 100 Was Full Divided Ught Grl ­0.31,% 0.19 0.43 mi : i Without 0.24 0.18 .0.42 CldIng lftdO' w Without Grilles 026 0.20 0.48 -AwrinilfidMrs Simulated Divided LjjeS Simulated Divided 0.24,­ 0.16 _R' �_et_G61ILL: -JIA-- 10 --" --0.42'- 0.24�,- 0.10 Firiallot Grilles 026 0.18 FinellglitGrilles, .38 '; 22'mrni glass _E- WI!t 11�GL E� Lej�pyV VdhU7 6 rA as 22 mm giass, w-Final! ExteflorAp 0.28', 0.18 0.42, Divided ivid Er Full Divided Ught Grilles F LJOA Gill 16 0 38 0.17 0.26 t Without Grilles 0.30 0.19 D30 __)��thoutGdlloa; _,_q.28 O.ii 16 .2"� 0.30. 0.27 0.27.r Simulated Divided Wit Grilles f Simulated Divided Uglit Grilles -'0.27' 0.17 0.16 0.24 a- A orApp- FinelightWith ExterlorApplied Grilles EnelI@j)KT d orAppIlLd Grilles Full Divided Upt Grilles 0 029- 0.16 24 Full Divided Ught Grilles :032� 0.17 • 0.27 0.28 WIthoutGrIlles 0.52 0.60 Without Grilles 0.46 0.53 4 0.'47 Simulated Divided UghtGrilles 031 0.47 0.53 Simulated Divided Ught Grilles 0.28 0.42 Finall tGrIlles .0.31-;' OX m­0.53 Gdll!!l 0.28 0.42 Enelll;�Mth EiderloAppl Grilles fnellgttW crApplied Grilles Uglit 0.42 0.47 0,32- 6.47 0.53« Full Divided L29 Full Divided Ught Grilles WithourtGrilles ��A.46.v",' 0.59 -0.62 Wlthout9� 2 4 0. M 0.55 Simulated Divided Likit qflLl��- I " , 1. Simulated Divided UittGrilles 6 0.53 (13'ws.� 42'-!-1 2 018 _6,48 53 0.55 Grilles O�42 .2 FlnellgitNthEteriarAppliedGrilles FlnellglitNtliDdeflorApp lied Grilles -Full Divided Ugli GifiiW.!7 42­D. :.' O.Z .49, Full Divided Ught Grilles 0.47 0.53 0.65, 1)U-Factor defines the amount of beat loss through the total unit In STI.I/hr-ftL*F.The lower the value,the less host is lost through the entire product.Window values represent non-tempered glass. congntied on ned page Use of tempered glass can Increase U-Factor ratings.See andersenwindows.com/nfrc for specific performance values.Door values represent tempered glass.2)Solar Heat Gain Coefficient(SHGC) defines the fraction of solar radiation admitted through the gins directly transmitted,as well as absorbed and subsequently released Inward.The lower the value,the less heat Is transmitted through the product.3)Visible Transmittance(Vr)measures how much light comes through a product(glass and frame).The higher the value,from 0 to 1,the more daylight the product lets In over the product's total unit area.Visible light transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. -NFRC:ratings are based an modeling by a third-party agency as validated by an Independent test lab In compliance with NFRC program and procedure[requirements, -This data Is accurate as of August 2023.Due to ongoing product changes,updated test results,or now Industry standards or requirements,this date may change overtime.Ratings Bra for sizes specified by NFRC for testing and cert1fication.Ratings may vary depending on unit size,use of tempered glass,different grills options,gloss for high altitudes,etc. -Values are for single units with given pone thickness and 3/0(19 mm)grilles for windows end 11(26 mm)plies for door proidue", 2024-26 100 Series Product Guide Page 1 of 4 1"ANDERSEN' 100 SERIES PRODUCT PERFORMANCE WINDOWS & DOORS NFRC Certified Total Unit Performance(continued) For current performance Information,please visit nft.org. Orri.666 Dual-Fqne Gassrypi `0.43'- Without Grilles cqGd[las 025 . .... Simulated Divided tight GiLlIes 0321;�3` 0.20 0.34 ::,:0,34. IvIded LIghtGrIlles 031"�A 0.21 myLated DIvId Flnell!Et Gdlles 0.32:..': 0.23 038' Flnelight"Grilles 0.31 0.23 `0.38 FnelightWiithS�d r ppile d Glj�es .32 020 03C.-f' fnellttWith Extero rApplIed Grlles Nil DvIdii gi1&0as DID Full DM DJ4`, 0.25 Without Grilles 029 0.25 0.42. Without Gdlles 028 SSSccc _Slr�ulatadl Divided Simulated Divided Light Grilles 0-20 0,31�z 0.20 0.33 7 Finaliglit Grilles 0.22 0.3T,, Fine Igit Gdlles 0.23 0.31' FlntilptwthE48to!lppl!eqGqIL--"",O;g 0. 0 - 033 1__03�: Ena_1MLw_bbw1!srApp'Led Grilles _, _020 -_R�L_L _, _ _, . OM -707 7Full Divided Light Gdlles 020 ;�4433 Full Divided Light Grilles 020 Without Grilles 031 J 0.17 0.38 70.31 :, 0.17 �-_0.38 Without Gdlles Simulated RiLidejkgl�t Grilles ".3 4 31 Slm�l led Divi d U t Grilles '031%; 0.14 j -0.34 Finallil Grilles A31 0.16 Finelljot Grilles 031' 0.15 FinalightWith LX�qrApprjed Gdljes 031 0.14 E 031f,�= 0.14 0.31' E neEietWIthWedLrApq�1edGrflIes "100 es .:I Full Divided tight Gdlles, !034 0.14 ,,Jo0rSedeS­­,:' Nil Divided Ught Grilles 0347,';' 0.14 _.,�,'0.31 Without Grilles:-:'029 0.17 ado Door e Sidllob ,Paldo Door mnsoms P Without Gdlles 028 0.17 i -AND-14-98 ''g Simulated Divele Simulated 14 0.14 Flnelight Grilles 019 0A5 Flnellb)t Grilles 02K-L'�:. 0.15 3.0 ram glass y LEiqftdorApqIled 9 J�FlnellghtWith Etelight�!�jl@xterfor lied Grilles -029' 0.14 -.0.30 3.0 mm glass Mae 028-., 0.14 0.30. Full Divided Ught Grilles 033 2 0.14 Full Divided Light Gdlles ',,,03 Without Grilles 0327 0.16 1`�0,24-'- MifthoutGrilles 03214 2�16 N", Simulated DividedUght G ,'032. 0.13 0.19,-�: Simulated Divided Light Gdlles 032- 0.13 0.19 FlnellttGrlll� ,L32 0.14 d','D.211 Finellgit Grilles OM lied Grilles 0.13 6.19, 0.13 0.19­m Tirialllp!LWOLE Lae��r Appll!g Grilks Full Divided Light 5'._'­` 0.13 �,A.19 Grilles Gq Full Divided Light Grilles 035.t! 0.13 i, 0,19: i Wh 0.41 i� :G.47_:-,%. Without St. 2012 OA2 0.47 d!�CtGdfles ID32 0.34 % 0.37,� Simulated Divided__.Lv�ul.teq Divided qg, Iles. L !gj_ 43 L'I__ 03L � _ 0.42 0 Firelight Grilles AM' 0.37 037 �0.42`; 037 With EdarlorApplied Grilles 032��:% 0.34 0.37 FlnelightWith EderiorApplied Grilles 033 -- - Full DivIdedLlfint Grilles Full Dlylded�ght O�5 6.3 4 37 - Without Grilles ­i OA5 OA7 -0,49%­ Without Gdllss�`,04C OX MW Sim ulaled Simulated Divided UglhtGrilles 0.45­ 038 dedLJ tGrilles 0.44 038 0.39, k 44 elight Gdlles 0.45_7�tjl A2i-- 0. 0.42 ­�,O. Fin ........... 8 Final] es O.W 0,38 o:,EnLtiptKitE e�?r�ppiiqRdles OA5, 038 `03 _el.Kq6qrI�,A pLIlad GdIl,. -,",.039 0.38 Full Divided Light Grilles ,' OAS Full Divided Uglit Grilles 1)U-Factor defines the amount of heat loss through the total unit in ErrLJ/hr­ftz*F.The lower the value,the lass beat is lost through the entire product.Window values represent non-tempered glass.Use of tempered glass can Increase U-Factor ratings.See andersenwindows.com/nfm for specific performance values.Door values represent tempered glass.2)Solar Heat Gain Coefficient(SHGQ defines the fractlon'of solar radiation admitted through the glass directly transmitted,as well as absorbed and subsequently released inward.The lowerthe value,the less heat Is transmitted through the product.3)Visible Transmittance(VT)measures how much light comes through product(glass and frame).The higher the value,from 0 to 1,the more daylight the product lets in over the product's total unit area.Visible light transmittance Is measured over the 380 to760 nanometer portion of the solar spectrum. :NFRc ratings are based on modeling by a third-party agency as validated by an independent test lob In compliance with NFRC program and procedural requirements. This date Is accurate as of August 2023.Due to ongoing product changes,updated test results,or now Industry standards or requirements,this data may change overtime.Ratings are for sizes specified by NFRC fortesting and certification.Ratings may vary depending an unit size,use of tempered glass,different grille options,glass for high altitudes,etc. -Values are for single units with given pane thickness and 3/40(19 mm)grilles for windows and 10(25 mm)grilles for door products. 2024-25 100 Series Product Guide Page 3 of 4 I"ANDERSEN' 100 SERIES PRODUCT PERFORMANCE WINDOWS . DOORS NFRC Certified Total Unit Performance (continued) For current performance information,please visit nfre.org. Anderien•Produet `I I =PerfomianceDdel-Psne.GlassType U-FactoP SHGCz. V@-e xTHighPrf gh WlthoutGdlfes 027- 0.32 -_0.56- _�WilhoutGrilles�-.0.29 0.32 �0.56' Simulated Divided light Grilles 0.27: 0_29 0.50,' w Simulated Divided U tGdlles 0.29 0.29 y~. 0.50 y Flnelight Gdlles 0.27-.'. 0.29 0^500", ,_'.•'� '` - Firelight'Grilles .' 0.29, 0.29 10.50 FlnellghtWit lFgt cr Applied Gdlles_,-: _ FnelightWthBdedorAppl led Grilles 1' Full Divided Ught Grilles-':029 029 0.50 - Full Divided Ught Grilles 0.94 4-0.29 0 50 ' { WRhout Gdlles -',0.25 .. 0,32 '0.55 _ _With outGdfles 0.233 -032 055 _ Simulated Divided Ught Grilles 0.23=;,- 0.29 0.49 r;--;'.: „ - ,� Slmulated_Divided U tGdlles y:0.25 029 -._ � _ _ Flnall tGdlles '0.25 029 0.49 _ FlnellghtGrilles -'0.23. 029 "0.49":':: Bh -- --- _ FlnelightWithF�dedarApplledGdlles - �_y.' _____ - 3 FlnellghtWllhFioedorAp Gdlles - Full Divided Light Grilles -0.27' 0.29 _ .0.49 Full Divided Ught Grilles ,'• 026`]` 0.29 -'0,49`., ;' �''' Without Grilles 027- 0.22 0.50 _ "'; Without Grilles i.028 0.22 0.50; Simulated Divided Ught Gdlles G;0.27,. 0.20 -0.45'+. ' - W Simulated Divided Ught Grilles `1�0�28 L__0.19 -0A5' i w= '': `:' ;r' ,;+'i' Flnall Gdlles -0.28 _ FlnefightGdlles 0.27 020 -.,0,45 { _ - , i 100,Sedes - N tnelllglblWith FAeriorApplied Grilles '- _ -_ - - , Finelight With FxdedorApplled Grilles Pieluro✓y Spedalty Full Divided Ught Grilles 029' 020 0.'45 1 io series:, Full Divided Ught Grilles ;0.30 -0.19 0.45 T Windows, __WithoutGrIlles_.'0.23 = 0.21 �0.49 ''? iiiensomWindowc ; __ Without Grilles ';025 - 0.21 0.49 ` i'- FlangeSetheck, SlmuletedDivitledUghtGdlles 0.23;u 0.19 �','0.44;'. ! p;N`�- - 1 SlmuletedDlvldedUghtGdlles "025V� 0.19 0.44` 1°Flange Setback,'' W Flnellght Grilles 0.23, ' 0.19 0.44';+ '` A d Flnelight Gdlles r. 0,25 y 0.19 0." .NmFlange and -,-- -_.. f:9 0 mm pass m Fin If. WM F�dedarApplied Grilles v) Flnelight With ExtedorApplied Grilles - _ - 3 gM Insect Frames. a, Full Divided Ught Grilles 025; " 0.49 0.44.y Full Divided Light Grilles , .027'''0.19 _ 0A4: AND-N-82 . Without Grilles 0.28 020 _ 031 _ Without Grilles .�-0.30.µ`0^20 '. '0.31 3.O mm glass'; ?: . w_� Simulated Divided UghtGrilles 0.28,- 0.18 028",, .-. _Simulated Divided Ugh[Gdlles _ _ �_ FlnelfghtGdlles028 �0.18 0.28- "1 FInallghtGdlies 030 0.18 �:.0.28 ' Flnel&Nth BdedorAppfed Grilles ,_ -_ - RnellghtWith F�dedorApplled Grilles Full Divided Light Grilles030.,• 0.18 0.28' :. Full Divided Ught Grilles .5 0.31 0.18 0.28 M WithoutGdlles' ':028"- 0.54 0.61: .: Without Grilles . :0.30:: 0.54 0.61'• s = Simulated Divided Light Grilles�U0�2g.::_ 0.48 0.55 -: Simulated DlvMed Light Gdlles • 039 0.48 0.55. _ F(nelightGdlles: 028 FlnelightGrilles 030 0.48^� 055 FlnelightWith 5dedorApplled Grilles+ FlnelightWith FatedorApplled Grilles __ _� WIIDvIdedUghtGdlles :..030: Full Divided Ught Grilles .0.31' 0.55•-,' _ Without Grilles ?,0.44 0,81 0.84-' Without Grilles 0.46 '' 0.g1 0.64 ' Simulated Divided Ught Gdlles 0A4'' 0.55 2" _Simulated Divided Ught Grilles ' 0.46-_. 0.54 0.557 =.F, _ FlnellghtGdlles 0.44,=„ 0.55 :',0:57+- "`` ' FlnelletGrilles ;•.0.48 "i 0.54 M^0,57. Flneli With 5dedorAp lied Grilles c Final! I,p�edGnllaS�.- _ ._ o Hht ��_._ _ Full Divided Light Grilles OAS 0,55 0.57. Full Divided Light Grilles 0.4T 0.64 0.57 __Without Grilles ;'0027u 0.36 jO.63 Without Grilles 0.30 `- 0.32 -0.55 w Simulated Divided Light Grilles " 0.27 _0.33^ 6- _Simulated Divided U t Grilles 0.30' 0.25 0.42 ,? Flneli r Grilles '.`:0.2f:•; 0.33 -� _ FlnellghP Gdlles_v.,_..,0.30 0.29 ,0:48 FlnelightWith F�dedorApplied Grilles '` - Flnellght Wdh FSdedorApplied Gdnes ;0.30 025 0.42 Full Divided Ug1mGdIIes ,,029 - 0.33 0.58 y,: Full Divided Ught Grilles 0.35 - 0.25 0.42�_ _ Without Grilles -0.23 Without Grilles `,u 0.26 0.32 0.54� Simulated DMded Light Grilles .023' 032 0 55 Simulated Diva ed Light Grilles ;.0.26 ,_025 D 41,' FlnelightGdlles 0.23 •, 032 055 FlnelightGrilles `0.26 Oy28 047 _ .'. FlneliglltWfth F�dadorApplied Grilles - _ _ 3 FlnellghtWith F�dedorApplied Grilles _-0.28. 0.25 041 Fill Divided Light Grilles'. 025 0 32 0 55 Full Divided Light Grilles '0.33- . 0.25 0:41' _ WlthoutGAlles i"'0.28' i 024_ '.'0.58 Without Grilles +":029_ _021 4.0.50; - r Simulated Divided Ught Grilles 0.29 0.17 `0.38.} w= Simulated 026':� 0.22 � 0.51�� ?,� , ;w� _._ _ 2 FlnelightGrilles 028 0.220.51; �FlnellghtGdlieslT, 029 .; 0.19__ 0.44 ,E FlneIIgMWfthFjdedorAppaedGdlles -' _ _ y FlneligMWdhEdedorAp piled Grilles �_, .17 0.38 �100 Series'.'': PoII Divided Light Grilles: 0.28- ^0.22 s'0.51._.. 100 series ` Full Divided Ugh(Grilles 0.34;. 0.17 -038' _ WithoutGriiles 0.22r 0.23 '10,55 611d1n PetloDaon` ' _ Without Grilles _`_0.26 0.21 0.49 Plchuo b Specialty.':r j -- g _�. WlndOte Simulated Divided U [_Gdlles,• 0.22 021 0,49 > ;AND•N•100 Simulated Divided Light Gdlles . "0.25 0.17 037 :rFlushFlnFreme i - f " _.. w _ Flnall tGrilles 0.25 0.19 -0.43' Flnall t Gdlles:`.0.22 �0.21 .0:49: $ OI AND N 192 u�i 3 FlnelightWfth FxdedorApplied Grilles ` -=" !;- 3.1'mm glass i ,�3 Flnellght Wdh F�dedorApplied Grilles 0.9"�_.0.17 .0.371-' Rill Divided Ught Grilles .024 021 - 0.49 - _ - - _ Full Divided Ught Grilles 0.32 0.17 "`037_ y3:ommgi ass:' -•_�; Without Grilles -0.27 •` 0.22 0.35,.r - Without Grilles '�,',,0,30,-� 020 031 w _ Simulated Divided Ught Grilles`, 027' 0.20 031 ,, 'Simulated DMIlded Upn Gdlles ,:0.30„_ 0.16 __0.23 N FlnelipJlt Grilles 027. _ 0.20 0_31:_ - 'y= _ Finellght Grilles 0.30 ___ 0.18 _ 0~.27' {. FlnelightWi11 SdedorAppIfed Grilles_' _ ' Flneligh[W U1 FxledorApplied Gdlles _ 030:'+ 0.16 •, '0.23, WII Divided Uglit Grilles : 029 020 - 031 - _ - Full Divided Ught 0.35 0.18 023 Without Grilles °'0.28 '•' 0.60 ;'0.69 WithoutGriiles : 0.310,53 063 '� n Simulated Divided Light G Simulated Divided Light Gdlles 028° 0.54 's^0.62' - Grilles 6.41 .0.46 ", _- - _ eli t Grilles 031 0.47 0.53 _FlnelfghtGrilles 028' 0.54 -'0g2.•. -•:: _ a .2 FlnBI! FneligMWahF�dedor I'm Gdlles 0_31 _0.41 �'046 i Flne11N1tn 5dedorAppliedGrilles Full Divided Light Grilles 029 - 0.54 Full Divided Ught Grilles- 0.35 0.41 '•0.46- Without Grilles: -0.48`: 0.88 0.72 i�"��.'. _ __ Without Grilles '0.48^�;� 0.60 ' 0.63. Simulated Divided Ught Grilles 0.46 0.61 0.64'._ ' -`- Simulated Divided Light Gdlles `0,48..,�` 0.48 • '0.48' Flne11�1tGdlles, MIS- 0.611 0_84" -- -_FlnelightGdlles �0:46 .. 0.53 0.55__; _ c FlnelightW_ith F�dedorApplled Gdlles :._ -', __ t c ,Fl_n_eIfgM With F�dedorApplied Gdlles 0.46 �0.46_ �0.48� PoII Divided Ught Grilles 0.47. 0.6- i 0 64; Full Divided Ught Grilles "0.49' 0.46 0.48 1)U-Factor defines the amount of heat loss through the total unit In 9TU/hr-ft2-°F,The lower the value,the less heat Is lost through the entire product.Window values represent non-tempered glass. contfnued on next page Use of tempered glass can Increase U-Factor ratings.See a ndersenwlndows.com/nfre for speclflc performance values.Door values represent tem pored glass.2)Solar Heat Gain Coefficient(SHGC) defines the fraction of solar radiation admitted through the glass directly transmitted,as well as absorbed and subsequently released Inward.The lower the value,the less heat Is transmitted through the product.3)In of ble Transmittance(VT)measures how much light comes through a product(glass and frame).The higher the value,from 0 to 1,the more daylight the product lets In over the product's total unit area.Visible Ilght transmittance Is measured over the 380 to 760 nonometer portion o1 the solar spectrum. •NFRC ratings am based on modeling by a third-perty agency as validated by an Independent teat lob In compllance wlth NFRC program and procedural requirements. •This date Is accurate as of August 2023.Due to ongoing product changes,updated test results,or new Industry stendards or requirements,this date may change overtime.Ratings ere for sizes sin ecllled by NFRC for testing and certification.Ratings may vary depending on unit size,use of tempered glass,different grille options,glass for high altItudea,etc. •Values ere(arsingle units with given pane thickness and s/n•(19 mm)gdIles for windows and 1•(25 mm)grilles for door products. •Windows with flush fin frame are avallable In select Southwestern states IncludingArizona,California,Nevada,New Mexico and Utah.Umited configuration mailability.See your Anderson suppl[or for more Information. 2024-25 100 Series Product Guide Page 2 of 4 1 V-l'i DECK TO GRADE 32" ......... ....... ......... ......... ......... .... ... ....... 0- 2X8 DECK JOISTS )c co TECO TO LEDGER BOLTED TO HOUSE FRAMING. -4— LINE OF EXISTING HOUSE I LINE OF EXISTING HOUSE —R (2) 2X6 GIRDER THROUGH ;oi BOLTED TO 4X4 ACQ POSTS z TO 12" DIA. CONC. FTGS. E @ 36 MIN. BELOW FIN. GRAD E 5/4 4 WOOD DECKING WOOD FRAMED DECK I it Lu Q < Lu D @9 CD Lli DN. 8" IN 15'-6'�-- 3, -L3'-6 12'-04 DECK PLAN DECK FRAMING 1 /4" = l'-O" 1 /4" = 11-0" 7 :D O if 5 /4x6 RAILING @ 36 ljj 4X4 POSTS 5 /4 x 4 HORIZONTAL RAILS ............................................ ....................................................................................................................... ...................... ................. ................ . ..... ................................................. < 5 /4x4 WOOD DECKING ...................... ...................................................................... ..................................................................... .................... ................................ ........................................................ L Q ........................... . .................... 2X8 @ 16 if OC DECK JOISTS L UJ TECO TO LEDGER @ HSE. ti Lr) ( 2 ) 2X6 GIRDER THRU BOLTED TO co 4X4 ACQ POSTS TO T 12 V?x8 if CONIC. FTGS @ DECK S E C T I O N 36 MIN . BELOW GRADE. 112 if 1 1 - 011 A� l DECK PLAN NE FRAMING I SECTION 11 . 8 . 23 77006 F F-5 - 7 2024 s JOAN CHAMBERS (631 )294-4214 b w 06 Z ro) 3„ O 8 104 0 O FLUOR. FIXTURE �I PLUMBING & ELEC. i! N @ EXIST. SHED W i co � // L.1.� D � Q r W N U � EXISTING HOUSE - NO CHANGES ui �. L O 00 0 C) v- r- PLUMBING & ELECTRIC IN EXISTING SHED A-2 3/8 " = 1 '-0" 1 1 . 8 . 2 3 PLUMBING & ELECTRIC IN SHED 1 1 .8.23 JOAN CHAMBERS (631)294-4214 c C)0 I— - - - - - - - - - - - - 0S � �'a DECK TO GRADE 32" LL Z I `. C4 it r o i 4Wo � a � �WW a cnc� Z�LI = 2X8 DECK JOISTS @ 16" OC I �.Y W m ?Z CC r F I TO HOUSETO LEDGER SE FRAMING.BOLTED I J m J LL c a opt 7�Wm (2) 2X6 GIRDER THROUGH I W J a Q O BOLTED TO 4X4 ACQ POSTS U n- , TO 12" DIA. CONC. FTGS. I Z co U @ 36" MIN. BELOW FIN. GRADE LINE OF EXISTING HOUSE i i LINE OF EXISTING HOUSE zo 5/4 x 4 WOOD DECKING I ` ' I Lurit � C WOOD FRAMED DECK Q � ov) C V 0 rr�r rsr Y ( I w W 0 r«r .w To 'ty GU DN. 8" I • I...... _._.... ._...... .......... .. _. ..._..... -.._... �... u. L L 0 12'-04" z w Lu a a p d Q O O o DECK PLAN DECK FRAMING a momo to 8 o � = O M w o z LL 1 /4„ = 1 -0„ 1 /4" _ �,_0" o g a Z n ¢ H o 8 cV Z ¢ oz Ow ct z p r o SNz a � `� �j� p, c�Sc a = N Z8 o � cLu ~nz aC � � O 00 c Z Em VQ � Q w O O ,.JWO O v n 5 /4x6 RAILING @ 36Lu 4X4 POSTS W 5 /4 x 4 HORIZONTAL RAILS fy ___.........----------------.._. --- _ _ __........._..._.........------ --.---_................... .......... --- __.........--....-.................................. r) . ... _..... _ _. ..._......._............................_...................... _ _....._....._._............._.._........._...............__ -_.........._......------ _ __................... -._...._..... _- ------ ct 5 /4x4 WOOD DECKING < < ._.._...-......_..........-_.._... ..._......_..._.__...._...._........._.._....................................._..........................- --....--......................-............._............................. _.........._.._..._..._.__.._....._...-- ---- ._..-...-.----._...----.._.__.....---- -- ---------- I` W N 2X8 @ 16 OC DECK JOISTS U TECO TO LEDGER @ HSE. _ ui ' ( 2 ) 2X6 GIRDER o THRU BOLTED TO pp p 4X4 ACQ POSTS TO 12 "x8 " CONC. FTGS @ DECK SECTION 36 MIN . BELOW GRADE. 112 if _ 1 1 _ 011 DECK PLAN FRAMING "E o� SECTION r W 11 . 8 . 23 sFo 77006 �� JOAN CHAMBERS p'��FESSIONP� (631)294-4214