HomeMy WebLinkAbout48343-Z �SUFFI a TOWN OF SOUTHOLD �o ay BUILDING DEPARTMENT y x 'TOWN CLERK'S OFFICE "ay SOUTHOLD, NY. 4 , BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit,#: 48343 Date: 9/28/2022 Permission is hereby granted to: Wilson, Thomas 1785 Breakwater Rd Mattituck, NY 11952 To: Install roof mounted solar panels to an existing single family dwelling as applied for. At premises located at: ` //-� 1785 Breakwater Rd., Mattituck (/ ��'" L' V 1//o SCTM #473889 Sec/Block/Lot# 106.-8-20.5 Pursuant to application dated 8/15/2022 and approved by the Building Inspector. To expire on 3/29/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $200.00 Building Inspector SO(/T,��# TOWN OF SOUTHOLD BUILDING DEPT. �yco 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ® � n- - DATE 3 aa'� INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS ro FOUNDATION (1ST) ►= ------------------------------------ C FOUNDATION (2ND) O ROUGH FRAMING& PLUMBING I Q LA r INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL CO MENTS _ o L X b H O x E� x d ro H o�g�1FF0(K�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT _� y2 H Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 15 Telephone(631)765-1802 Fax(631) 765-9502 hftps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT H For Office Use Only , IZV LL�I AUG 1� 5 gn99 PERMIT NO. I Building Inspector: BUILDING DEP-r Applications and forms must be filled out in their entirety.Incomplete TOWN OF SOU HOLD applications will not be accepted. Where the Applicant is not the owner,an ..Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name:Mary Lou Wilson._._..- sCTM#1000-106-8-20.5- Project Address:1785 Breakwater Road,_Mattituck, NY 11952 Phone#V516-606-9663 _ _ _ Email_luvmyjets@gmlaiLcom Mailing Address_1785 Breakwater Road. Mattituck, NY 11952 CONTACT PERSON: Name: Tammy Lea/Sunation_Solar Systems Mailing Address: 171 .Remington Blvd„ Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email: ermittin su nation.com 'DESIGN PROFESSIONAL INFORMATION: Name: William Fisher Mailing Address:509 Sayville Blvd, Sayville,NY 11782 _ Phone#:631-786-4419 Email:bill@sher-ny_.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems _ Mailing Address:171 Remington Blvd.,_Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:pqrmittingasunation.com DESCRIPTION OF PROPOSED CONSTRUCTION' ❑New Structure ❑Addition MAlteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Solar panels flat on roof $ R1�D3S•OD [Will the lot be re-graded? ❑Yes MNo Will excess fill be removed from premises? ❑Yes MNo 1 PROPERTY INFORMATION. Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes @No IF YES, PROVIDE A COPY. i _ . 0 Check Box After Reading: The owner/contractor/deslgn professional Is responsible for all drainage and storm water Issues as provided by. Chapter 236 of the Town Code.APPUCATION IS HEREBY MADE to the Bullding Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,.County,New York and other applicable Laws,Ordinances or Regulations;for the construction of buildings, additlons,alterations or for removal or demolition as herein described.The appllcant agrees to comply with all applicable laws,ordlImnces,'•bulldingcode, housing code and regulations and to admit authorized Inspectors on premises and In building(s)for necessary Inspect)ons.False statements made herein are . punlshable,as a Class A misdemeanor pursuant to Section 210.4S'of the New York State Penal Law. i Application Submitted By(printhame);_S-cott Maskin @Authorized Agent []Owner Signature of Applicant: Date: t��apl a STATE OF NEW YORK) SS: COUNTY OF,Suffolk ) Scott Maskin • being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,.Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application,that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work/will be performed in the manner set forth in the application file therewith. Sworn before me this . daY of Deco"be'.- 20 d r 7 -lipfary Public TAMMY LEA Notary Public..State of New York Registration No.OILE6410842 PROPERTY OWNER AUTHORIZATION Qualified In Suffolk County ,1�( (Where the applicant is not the owner) Commission Expires November 2,20 ,,,Mary Lou Wilson residing at 1785 Breakwater Road Mattltuck do hereby authorize -Scott Maskin to apply on my behalf to the Town of Southold Building Department for approval as described herein, Dec 20 2021 Mary Louise Wilson(Dec 20,202110:16 EST) , Owner's Signature- Date Mary Lou Wilson Print Owner's Name 2 ff��� of c BUILDING DEPARTMENT- Electrical Inso� �oi �G TOWN OF SOUTHOLD w�OFNGo •� �.►�� SO T pr Town Hall Annex- 54375 Main Road - PO Box 1 liyk)to o � Southold, New York 11971-0959 y,�i O®��!'' Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr _southoldtownny..govTseandasoutholdtownny.-gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: ermittin sunation.com Address: 1.71 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Mary Lou Wilson ; Address: 1785 Breakwater Road, Mattituck, NY 11952 Cross Street: Phone No. 516-606-9663 Bldg.Permit#: � 1�� email: luvmyjets@gmail.com A Tax Map.District: 1000 Section: 106 Block: 8 - Lot: 20.5 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of solar panels -flat on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph .3 Ph Size: -A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected- Underground -Overhead #Underground Laterals 1 2 H Frame Pole' Work done on Service? Y N -Additional Information' PAYMENT DUE WITH APPLICATION Request for Inspection FormAs MOD .1 r �tj N Y S I F PO Box 66699,Albany,NY 12206 New York State Insurance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 753118816 0• '0 GCG RISK MANAGEMENT INC 100 CHURCH STREET-SUITE 810 ' NEW YORK NY 10007 ■ SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 670-2 243630 01/01/2022 TO 01/01/2023 12/14/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE'INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS:/AMWW.NYSIF.COM/CERT/ CERTVAL.ASP..THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE.COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 103973329 111111II00000001111110 Big 000009940330 min[Minz4�I Form WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-21606702] U-26.3 64 [00000000000099403304][0001-000021606702][!!Z][15762-06][C�NoP- 1][01-00001] A� CERTIFICATE OF LIABILITY INSURANCE °A2/11/202/2 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: The Horton Group PHONE FAX 10320 Orland Parkway ac No Ext:708-845-3000 Arc No): IL Orland Park IL 60467 ADDRESS: certificates@thehortongroup.com INSURERS AFFORDING COVERAGE NAIC# INSURERA:Evanston Insurance Company 35378 INSURED SUNASOL-01 INSURER B:The Continental Insurance Company 35289 SUNation Solar Systems, Inc. 171 Remington Blvd INSURERC:AXIS Surplus Insurance Co. 26620 Ronkonkoma NY 11779 INSURERD:Travelers Property&Casualty Company of America 25674 INSURER E: INSURER F COVERAGES CERTIFICATE NUMBER:1814587511 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICPOLICY NUMBER MM/DDY EFF POLICY EXP MM LTR /DD/YYYY LIMITS A GENERAL LIABILITY Y Y MKLVlENV103336 2/1112022 2/11/2023 EACH OCCURRENCE $1,000.000 X COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED PREMISES Ea occurrence $300,000 CLAIMS-MADE F—IOCCUR MED EXP(Any one person) $10.000 PERSONAL&ADV INJURY $1,000,000 GENERAL AGGREGATE $2.00D,000 GEN'LAGGREGATELIMITAPPLIESPER: [PRODUCTS-COMP/OP AGG $2,000,000 POLICY FXJ PRO- LOC $ B AUTOMOBILE LIABILITY Y Y 7018308202 2/112022 2/112023 COMBINED SINGLE LIMIT Ea accident $1 000 000 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ 1AUTOS Per acc dent C UMBRELLA LIAR X OCCUR Y Y P-001-000795195-01 2/112022 2/11/2023 EACH OCCURRENCE $3,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $3.000.000 DED I I RETENTION$ $ WORKERS COMPENSATION WC STATU- OTH- AND EMPLOYERS'LIABILITY Y/N LIM TER ANY PROPRIETOR/PARTNER/EXECUTIVE❑ NIA E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below I I E.L.DISEASE-POLICY LIMIT $ D Builders Risk Y Y QT-630-2T010874-TIL-22 2/112022 2/11/2023 500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,If more space is required) Additional Named Insureds:SUNation Service Inc;SUNation Electric Inc;SUNation Commercial Inc;SUNation Cares Inc Additional Insured on a primary and non-contributory basis with respect to general liability and auto liability coverage when required by written contract.Waiver of subrogation applies to general liability and auto liability in favor of the stated additional insureds when required by written contract.Excess follows form. Town of Southold is included as an additional insured as required by written contract and the CG 2012(State,Governmental agency,or Political subdivision permits or authorization)is included on the policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD NEW workers! workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1 b:Business Telephone Number of Insured SUNATION SOLAR SYSTEMS INC 631-737-9404 171 REMINGTON BOULEVARD RONKONKOMA,NY 11779 1 c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,wrap-up Policy) 753118816 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"1 a" PO Box 1179 DBL631187 Southold, NY 11971 3c.Policy effective period 10/01/2021 to 09/30/2022 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 12/1/2021 By wid hf (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 48,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 111111111D°°°1°1°1°°1°1°�11°!�°�°�!�!°IIIIII c • 1 1 � a• 'ib ' Suffolk County Dept of Labor,Licensing&Consumer Affairs ` MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN i i Business Name This certifies that the I bearer Is duly licensed SUNATION SOLAR SYSTEMS INC by the County of suffolk i 4 License Number:ME-33412 Rosalie Drago Issued: 06/24/2003 Commissioner Expires: 06/01/2023 f I I r I I s I I f � I r �•' RE:CEIPT SUFFOLK COUNTY GOVERNMENT DEPARTMENT OF LABOR, LICENSING,AND CONSUMER AFFAIRS ACTING COMMISSIONER ROSALIE DRAGO P.O. BOX 6100, HAUPPAUGE, NY 11788 _(631) 853 4600 Today Date: 02/25/2020 Application: H-44104 Application Type: Home Improvement License Receipt No. 402742 Payment Method Ref. Number Amount Paid Payment Date Cashier ID Comments Check 31300 $400.00 02/25/2020 GAB Renewal Contact Info; SUNATION SOLAR SYSTEMS INC SCOTT A MASKIN 171 REMINGTON BLVD. RONKONKOMA, NY 11779 Work Description", Suffolk county Dept.of po Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE I , Name SCOTT A MASKIN Business Name `This cer irvs that the SLINATION SOLAR SYSTEMS INC bearer is duty licensed by the county.of$.- k License Number:H-44104 Rosalie Drago issued: 03/06/2008 Acting commissioner Expires: 0310112022 f a UT APPROVED AS NOTED DATE -aa B.P. # FEE m 'Q BYT ODES OF NOTIFY BUILDING DEPARTMENT COMPLY WITH ALL C 765-1802 8 AM TO 4 PM FOR THE NEW YORK STATE & TOWN CODES FOLLOWING INSPECTIONS. 1. FOUNDATION-TWO REQUIRED AS REQUIRED AND CONDITIONS OF FOR POURED CONCRETE SOUTHOLD TOWN ZBA 2. ROUGH-FRAMING,PLUMBING, STRAPPING, ELECTRICAL&CAULKING 3. INSULATION SOUTHOLD TOWN PLANNING BOARD ` °; 4. FINAL-CONSTRUCTION &ELECTRICAL MUST BE COMPLETE FOR C.O. SOUTHOLD TOWN TRUSTEES ,:f a, ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW N.Y.S.DEC YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. -x JirDc0x)nQc+ rnus+ b� loco Fed readl I y accer::)S�61c . ELECTRICAL INSPECTION REQUIRED Q ! UTILITY DISC PROPOSED RESIDENTIAL PLAN KEY "Q-'-SERVICE DISCONNECT PV1-0 COVER SHEET F-9-SUPPLY SIDENEN Ai-1 PARTIAL ROOF PLAN P'-AUTOMATIC MANSFRSWI TCH PHOTOVOLTAIC SYSTEM A1-2 ATTACHMENT SPACING PLAN E)-GAS METER ©-MAIN SERVICE PANEL �k1-4 ROOF ACCESS PLAN WIRELESS ROUTER�!, SUB PANEL SUNATION SOLAR SYSTEMS NYSERDA 4355 ©- STRUCTURE 171 REMINGTON BOULEVARD INSTALLER - E1-1 ONE-LINE DIAGRAM g-INVERTER RONKONKOMA,NEW YORK 11779 NUMBER E2-1 PV LABELS Q-ENPHASE 1000MBINER ♦ ♦ ♦ ♦ Tr♦ ♦ T T ♦ ♦ ♦ . Wilson Residence G1-1 PV PHOTOS ®-PANELPHOTOVOLTAIC iw° unw.a°ms T . ♦ . . . . . . T . . . . 1785 Breakwater Road, Mattituck, NY 11952 ❑J-ELECTRIC VEHICLE CHARGER ®-ENPHASE ENVOY T T ♦ ♦ ♦ ♦ ♦ ♦ ♦ T 0-SENSE CONSUMPTION MONITOR Drawn By:T. MacCallum -08/09/2022 ®-AC DISCONNECT ern TESLAGATEWAY C r F ®-TESLAPOWERWALL '(, O f ENPHASE 10 LOAD CONTROLLER %r,� �0 FISHER ENGINEERING SERVICES, P.C. ®-ENPHASE 1010 BATTERY I - - _ � 509 Sayville Boulevard ®-ENPHASE 103 BATTERY a •, _ .i Sayville, New York, 11782 Q-GENERATION PANEL a' ' y Lv a a .. � Licensee No.074659 EDP BACKED UP LOADS CENTER , a F_ - � L� �O•Ci 1rOSa . (631)-786-4419 0-VENT PIPE Bill@Fisher-NY.com I ,, / ESS ONP� Ga!/GQiL ^-EXTERIOR LOCATION -1ST FLOOR LOCATION -BASEMENT LOCATION , ; 5• ' Building Review Note -GARAGE LOCATION Town building examiner has received the enclosed document for minimum acceptable plan submittal requirements of the town as specified in the building and/or Residential Code of the State of New York. This review does not guarantee compliance with that PROPOSED PV SYSTEM code. that responsibility is guaranteed under the seal and signature of the New York State licensed design professional of record. That seal and signature has been Module Type/Qty: (86) LG375Q1 C-V5 interpreted as an attestation that,to the best of the licensee's belief and information the work in this document is: Module Dimension: 66.9"x 44"x 1.57" Accurate • Conforms with governing codes applicable at the time of submission Module Weight/PSF: 38.58 Ibs/2.1 PSF I Conforms with reasonable standards of practice and with view to the safeguarding of life,health,property and public welfare is the responsibility of the Micro Inverter: (86) Enphase IQ8PLUS-72-2-US licensee. i System DC Rating: 32.25 kWro ° Structural Statement Estimated AC Production: 39,415 kWh/yr ' r T ♦ T T T r ♦ • The existing structure is adequate to support the new loads imposed by the Production Source: Aurora photovoltaic module system including uplift and shear. The existing rafter sizes and dimensions conform to IRC-2018 table R802.4.1(2)-Rafter Spans. 7 ♦ TTT �' TT7 � T n„ter mow , PV Notes 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be provided where necessary. An in depth description of each applicable code _ reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the solar equipment. 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and inspection. FULL HOUSE ROOF PLAN SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PV1 =0 �C r COVER PAGE JOB# 20-279 AUG :+ "f ri REVISION # N/A BUILDING DEPT SUNation rnN/A Solar as it should be REVISED BY OF NFIy 1 - tea' °•O14E5� .•ram CIRCUIT 6 RIDGE 3-, FISHER ENGINEERING 48•4° Z,-e• SERVICES,P.C. RIDGE CAPPING 509 Sayville Boulevard �___� _____________ < R.R.-2"X 10"� (TYP) r << @ 15 O.C.VENT PIPE Sayville,New York,11782 nsee No. ROOF 3 ® • • • 3„0®�® 1 LiclgFis786-441959 6 ® ` Bill@Fisher-NY.com • a • • • • • i •• • • • • • • • • • • • ®� • @ 7 6 Tr C 6 U" i5 W A d7 a'+ L➢ 0 C9 Ci � t3 a d7 f' C+ 4 6 6 f1. r9 Q � Q+ t� d • � ; SUlolation ® Solar as It should be PHOTOVOLTAIC MODULE ( • SUNation Solar Systems I�P I 9� 171 Remington Blvd. • '44A • • • • D • • • • • • ® • • • Ronkonkoma,New York 11779 Y • • ••6 • • ® ce ® • ® • • ® ® ® • • (631)-750-9454 ® , CIRCUIT4 NYSERDA INSTALLER „ 3 5 5 � • � lL NUMBER tl.l • VENT PIPE (D a �3"OPVC 38''°0 JOB NUMBER _ ROOF AREA � ® , L CIRCUIT 5 CIRCUIT 7 GUTTER L CIRCUIT 8 20279 • RIDGE ROOF 2 20•-B, • 3'-1° VENT VENT PIPET VENT 3'c• RIDGE • 14"X 14" 310 PVC i ^74"X 14° g• ® N ROOF o ° Lo T V/ 0 — C\1 V/ } N 5 RIDGE • O Y o V 41 00 3yZ° CIRCUIT 3--- Y C) U_ m E a, O O Co Z 0 co YKT/ 05 U) � 3 m TV co C: In Ca r- CIRCUIT 1 L CIRCUIT 2 GUTTER Attachment Spacing: Portrait Attachment Spacing: Landscape n' Roof# � Roof Description Modules Azimuth Tilt Pitch I , V Interior Edge Corner Interior Edge Corner A 1 Southeast Roof 26 1540 26° 6.9/12 64" 32" 16" 6411 48'1 4811 1/811- 1'-011 2 BOH Southwest Roof 18 j 244° 220 5.9/12 6411 3211 1611 64114811 4811 3 South Roof 42 170° 260 6.9/12 6411 3211 16" 1 64'1 4811 4811 Al 1 PARTIAL ROOF PLAN tSOLAR ENERGY SYSTEMS ()F NFIy (NY) R324.6 Roof access and pathways. Roof access, pathways and `�P��`°m G.Fs4 J- 0 10 setback requirements shall be provided in accordance with Sections P '324.61 through R324.6.2.1. Access and minimum spacing shall be )quired to provide emergency access to the roof,to provide pathways `� ,,.••— 4`I specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. ,, J• c��? �J' �Sa'"c Exceptions: DErACRED PDOL RDDSE FISHER ENGINEERING 1. Detached, nonhabitable structures, including but not limited to SERVICES,P.C. detached garages, parking shade structures, carports, solar 509 Sayville Boulevard trellises and similar structures, shall not be required to provide Sayville,New York,11782 roof access. Licensee No.074659 2. Roof access, pathways and setbacks need to be provided l9Fisher-4419 BiIIC�Fisher-NY.com where the building official has determined that rooftop operations will not be employed. 7 r 7 ® � ` T p J IJJI PROORED PV MDD'JIEi y y 3. These requirements shall not apply to roofs with slopes of two ) units vertical in 12 units horizontal (17-percent slope)or less r w ��N should be sre y N R324.6.1 Pathways. Not fewer than two pathways, on separate 7 7 r 7 v e e �► SUNation Solar Systems [ Y P Y P a 171 Remington Blvd. roof planes from lowest roof edge to ridge and not less than 36 inches Ronkonkoma,New York 11779 (914 mm)wide, shall be provided on all buildings. Not fewer than one w (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. N For each roof plane with a photovoltaic array, a pathway not less than NYSERDA 4355 36 inches (914 mm)wide shall be provided from the lowest roof edge INSTALLER to the ridge on thee same roof plane as the photovoltaic array, on an NUMBER o adjacent roof plane, or straddling the same and adjacent roof planes. _ Pathways shall be over areas capable of supporting fire fighters o JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal - ® ' 3 20279 obstructions such as vent pipes, conduit, or mechanical equipment. Pathways on opposing roof slopes shall not be located along the same R sD plane as the truss, rafter, or other such framing system that supports `� ` _ "Y_` PTHDI ",D pathway. 5 _ --:ception: - - N 1. Access pathways shall not be required on roof slopes containing '� / _ o"', photovoltaic modules, panels, or an array where the opposing d / o or adjacent roof slope is an access roof, z Z PRO—EDPVMDDULEa \ ! - - - + - - O U co Access Roof-A roof surface that: E " H a) 16 E 1. Can be accessed from the ground by the fire service. cn ' 2. Is capable of providing fire service access to the ridge or peak 0 Ir c of an opposing or adjacent roof surface that contains Z o LL co photovoltaic modules,panels,or an array. W 3. Is relatively free of vents,skylights,conduits,mechanical 7 equipment and other such obstructions. N m m 4. Does not contain photovoltaic modules, panels or an array,or is m a single ridge roof where the maximum edge to edge width of ,n o the photovoltaic panel system does not exceed 33 percent of n the ridge length. I T -Is•-vE"nuYnR [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be ❑ ❑ located less than 18 inches(457 mm)from a horizontal ridge. [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels T T and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. T T O �► A pathway not less than 36 inches (914 mm)wide shall be provided to the emergency escape and rescue opening. N 12R1 PROPOSED Pv MDCULES i j A1 =4 ROOF ACCESS PLAN 4 OF NFG� Typical Attachment Method 0 of (41 SNAP'N'RACK ULTRA RAIL RIDGE RIDGE �L-FOOT AND RAIL ASSEMBLY FISHER ENGINEERING SERVICES,P.C. PHOTOVOLTAIC 19'-11" PHOTOVOLTAIC 20'-1" 5os Sayville Boulevard ® Sayville,New York,11782 Licensee No.074659 MODULE MODULE (631)-786-4419 Bill@Fisher-NY.com 3/4"MODULE SPACING 3/4"MODULE SPACING (2)S.S.304 5.OMM X 60MM BETWEEN ROWS AND BETWEEN ROWS AND WOOD SCREW FASTENER i ,�\ SUNatII®l� COLUMNS(TYP.) 10 COLUMNS(TYP.) Solar as i4 should be RT-MINI ROOF ATTACHMENT SUNation Solar Systems RAIL RAIL MOUNTED Ronkonkom71 a,Remington Yorki RAFTERER 1779 (631)-750-9454 RAFTER RAFTER (1)LAYER SHINGLASPHALT o INSTERDA ALLER 4355 2"X 10"/16"O.C. 2"X 10"/16" O.C. SHINGLE(TYP.) INSTALLER NUMBER JOB NUMBER SOFFIT SOFFIT 20279 PLYWOOD DECKING EXTERIOR EXTERIOR (TYP-) WALL WALL WOOD FRAMING -10 16'-5.25" —I 16'-7.5" —I (TYP.) ATTACHMENT TYPE APPLIED TO-ROOF"1,2,3" ROOF SECTION (TYP.) - ROOF "1&2" ROOF SECTION (TYP.) - ROOF 1'3" SCALE: N.T.S. SCALE: N.T.S. � N r N } N Z rn 0 Z m o v �SOLAR MODULE FRAME O NOTE:3/4"SPACING E BETWEEN MODULE ROWS a S e o o c o AND COLUMNS. G Roof# Rafter Size/Spacing Max Span Material Layers Sheathing A T O (nCZ 1 2"x 10"/16" O.C. 16-5.75" Composite Shingles 1 Plywood HEIGHT ADJUSTABLE LL co L-FOOZ 0 co o c 2 2"x 10"/ 16" O.C. 10'-7.5" Composite Shingles 1 Plywood END CLAMP w 0 3 2" x 10"/ 16" O.C. 16'-7.5" Composite Shingles 1 Plywood ei 71 tI\- SNAP'N'RACKi o i Ol ULTRA RAIL Cl) —CcZis 4) HEIGHT OFF OF i ROOF SURFACE mCIJ LIT Q FIT MINI 2 00 (TYP.) Typical Module PEST WRAP CUT T AWAY FOR Side Profile CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX MEAN ANNUAL GROUND SNOW SPEED(MPH.) TOPOGRAPHIC SPECIAL WIND ZONE WIND BORNE DEBRIS CATEGORY WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE REQUIRED TEMPERATURE S 1 1 LOAD EFFECTS ZONE 20 PSF 140 B YES 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE OF Util N£!�, P.����m 1 zorzaov T �0 ,f Enphase A/C Branch Circuit(typ.) ity Service -7- EXISTING n o MGENERATOR 2 Enphase Microinverter(typ.) SUPPLY-SIDE • • �.J /° C%465`' CONNECTION ti COMBINER t Module J-Box(typ.) a PANEL TENPHASE GATEWAY (N°lHASE anifannganlyl 150A 1 150A 1 400A 1 200A l 200A 1 FISHER ENGINEERING PV Module(typ.) zPzoA zP15A MAIN J MAIN J MAIN J MAIN / MAIN J SERVICES,P.C. 509 Sayville Boulevard Circuit#8 Gateway ENPHASE ENVOY s — 6 s — Sayville,L ce New a No.York, 11782 EGC Attached To Rail(typ.) 2P20A (No i°aas.m°nuo'gonlyl 2P20A Circuit#7 Envoy Automatic f� — Relay s _ s _ l@Fis786-4419 2P20A GARAGEPV • Bill@Fisher-NY.com ENPHASE BRANCH CIRCUIT#8 Circuit#6 _ PassThru ENPHASE BRANCH CIRCUIT#7 2P20A Circuit#4 Lug !eee ¢ Circuit#5 f� w �®, ENPHASE BRANCH CIRCUIT#6 2P2oA 2PzoA y StJNati®n G ¢ circwt#a C"cu'#t , Solar as it should be ENPHASE BRANCH CIRCUIT#5 — ENPHASE TRENCH Cucu�#2 G SUNation Solar Systems EGC J IO COMBINER 3C 171 Remington Blvd. G ENSE MONROR qC DISCONNECT G G G Ronkonkoma,New York 11779 ENPHASE BRANCH CIRCUIT#4 "01vaps"""""'"9°"N� AUTOMATIC MAIN MAIN PANEL TRANSFER SERVICE SERVICE (631)-750-9454 e ENPHASE BRANCH CIRCUIT#3 PHOTOVOLTAIC ) SWITCH PANEL PANEL NYSERDA 4355 z ENPHASEBRANCHCIRCUIT#2 1 2 3 Note:Leave a blanks m TRENCH above each Enphase —�� INSTALLER iENPHASE BRANCH CIRCUIT#1 ROOF ATTIC EXTERIOR branch cirr uttbu Baker per c � NUMBER EGC— ma 6 JOB NUMBER BUILDING 20279 GROUNDING ELECTRODE CONDUIT AND CONDUCTOR SCHEDULE TAG CONDUCTOR CONDUIT RUN TYPE GAUGE QUANTITY TYPE SIZE LENGTH 1 Enphase Q-Cable 12 16 N/A N/A 15' 2 Type NM 10 16 N/A N/A 30' 3 HWN-2 10 16 PVC SCH.80 1.25" 15, N GC 4 1 PVC SCH.80 1.25" 15' Ln 4 HWN-2 4 3 PVC SCH.80 1.25" 135' O N N GC 8 1 PVC SCH.80 1.25" 135' r- 5 HWN-2 1/0 3 PVC SCH.80 1.5" 130' } N z 0) GC 6 1 PVC SCH.80 1.5" 130' O 00 6 HWN-2 1/0 3 PVC SCH.80 1.5" 10, Z 0) j O GC 6 1 PVC SCH.80 1.5" 1 10, U fX a CZ O 1 U z C: o Cz Circuit# PV Module Oty Micro-Inverter oty. Maximum AC Operating Current U) 1 1_13375101 C45 13 Enphase IQ8PLUS-72-2-US 13 15.73 A � a 2 1_13375101 C45 13 Enphase IQ8PLUS-72-2-US 13 15.73 A co 3 LG37501 C45 10 Enphase IQ8PLUS-72-2-US 10 12.1 A m Cz LO00 p 4 LG375Q1 C45 8 Enphase IQ8PLUS-72-2-US 8 9.68 A 5 L13375101 C-V5 3 Enphase IQ8PLUS-72-2-US 3 3.63 A T 6 LG375Q1 C-V5 13 Enphase IQ8PLUS-72-2-US 13 15.73 A 7 LG375Q1 C45 13 Enphase IQ8PLUS-72-2-US 13 15.73 A 8 LG37501 C-V5 13 Enphase IQ8PLUS-72-2-US 13 15.73 A Maximum AC Operating Current(Total) 104.06AE1 = 1 ONE-LINE DIAGRAM �F. OF GN�� LABEL LOCATION: I LABEL LOCATION: PHOTOVOLTAIC CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ — — • — MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE �' - CEILINGS/FLOORS OR MORE THAN 10'. DISCONNECT IF APPLICABLE. POWERSOURCE 1 of 4 NEC 2017 690.31(G)(3) NEC 2017 705.10 wa "o ;4659 Sec • e Disconnect PHOTOVOLTAIC DISCONNECT LABEL LOCATION: MAXIMUM AC OPERATING SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND • • • FISHER ENGINEERING CURRENT VALUES ON DISCONNECT LABEL. SERVICES,P.C. NOMINAL •. . 509 Sayville Boulevard Sayville,New York,11782 NEC 2017 690.54/NEC 2017 690.13(B) NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO Licensee No.074659 (� (631)-786-4419 i - �; THE BUILDING MAIN SERVICE DISCONNECT. Bill@Fisher-4419 f This building is equipped:with an 7ELECTRI( L `� Servic_ , • nnectInterconnected Electric Povver ���- SUNa ion LEProduction Source i `� Solar as It should be • •' • = SUNation Solar Systems SHOCK HAZARD ' - - --- - - _- r' Source Type;",'.i 171 Remington Blvd. Ronkonkoma,New York 11779 DO NOT TOUCH TERMINALS Disconnect 5olar;Photovoltaic;' (s31)aso-sa54 TERMINALS ON BOTH THE LINE AND - r Disconnect is Located: ,Interior._ }' NYSERDA LOAD SIDES MAY BE ENERGIZED _ ;easement:- ' Garage: ",Exterior Located - INSTALLER IN THE OPEN POSITION Front:_.. 'Rear. LH Side:_ • • ® •LTAIC SYSTEM 4355 PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE j ".RH,Side:_,O1her,Location: :'- .•: NUMBER WHENEVER THEY ARE EXPOED TO SUNLIGHT I' '_-• SUNation•Solar $ystems'y"' • f• ' " ' JOB NUMBER t 631750-9454 { www.sunation.com . . 20279 CV L0 CA C\I r CV >- N Z rn 0 00 z a) o O 0 } O a) ca fz U W O co � m C In tt3 L LO 00 T Iy\ E2= 1 PV LABELS • "-Nt7tWhUUdfiAflu513B}I65111C'bll�;ic q'� +''v:w'ro.��,,,tia;...�•c�.�� .�'1�i `t�f<r �r �} ��� _._ �� 1'S;.t 3T ��. �� �'�._. �.*��` y (SR r '�"" .Ai .t 1 4� � t • 5 � 1• :. . "'?I� ��.�.. .1' L f` 'U f r- # r y 1 Fa_ -.,. + ifr 4� �.p'• 'i F.t' �. `/ :1 , "� -fit` `o-. ,( _�, �•r. .`Y .Y"`"..' ..,....�—55"OQ #: r�''Sr`s it'+a, •�.-� ",. ot- 77 Jf �t � .e•'F'�� f�rk�'r - .•'t•••w�.a ,,Te{,, 1 ��1T� ��L- Y[-"" ���t ;'�.,, ,'15Y� �L. ..j• r.,s/� 'N•i n •� ' V X {ice'-y"`�--����j�._ i.•,�� � l 4 - � r,IZ.+/ ! Sr. �.�:" � .'Y•►•1.>Y„ J �.. k+ _ .. .,,9+^ .. .., ` '.YJ��X7 �r �"r _�'_ � ^`�'` -- '9 -'' tv'.'' �.7~-'•' J, :�h ly;. �P�,'� ;ti•�,. �eOf17IOf?�{ti V �+ n 1 R+r:;k yJ�� .�"•'� �- _ •` -2Y;, _ f k. -sl t / .� � • '� �� � �, Ti r 1 1 1 r r' It i {_��!� �-� "'. r �� ''. ' �� i��, ~^ � >t.:;,. F< � )'� i•fl�"h�`c`-n�f._f xt+tar. � � �j3 � 1 ,i� .. .. ,.'}` •,;„za. ti-^��_'a. 11 ! •^ta..`ab• `w� .'"t (,.V W- %��'' ,�`-L7 ,. �' ' � .R�' ''„° al,. � •' 1. ., r !' ^��1av � l.,;yC+`�\t '♦'�J CP � II '�:Jf � 4. '�. .a•r rr+= ✓}�,wN. , #• 1 1. ,�• '� � ": jSL�v t 11..7 o i L� ' � � ,a ■ .i i�ticc711 . won a A on i OF NEB, LABEL LOCATION: �Q \\\plr G•f sf /� LABEL LOCATION: Cl) WARNING- ► CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ Service DisconnectMAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE DISCONNECT IF APPLICABLE. i CEILINGS/FLOORS OR MORE THAN 10'. o. NEC 2017 705.10 NEC 2017 690.31(G)(3) cj n o e • ed • 6 D e LABEL LOCATION: Located o Meter © FISHER ENGINEERING s= - SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND SERVICES,P.C. o. . CURRENT VALUES ON DISCONNECT LABEL. 509 Sayville Boulevard Sayville,New York,11782 NEC 2017 690.541 NEC 2017 690.13(B) _ Licensee No.074659 x^-~_~ NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO (631)-786-4419 "� i THE BUILDING MAIN SERVICE DISCONNECT. Bill@Fisher-NY.com fihts'buildct irig.is,equipped.withari, c `' IriEeWeonnected:Electric-Pgvve�`r , a SUNat9®n ji r� I ® '. `r.. - ., _a, _ `~ Solar as it should 5e Production Source j 'r �, T� _ — -p, SUNation Solar Systems ELECTRIC SHOCK HAZARD jTj s - - - f 171 Remington Blvd. I: SourceTYpe?',,:,,r-• ;;t==.':;. Ronkonkoma,New York 11779 DO NOT TOUCH TERMINALS _ s% 5ola,�^Photovoltaic;"" - '•trF fi (631)-750-9454 ® e TERMINALS ON BOTH THE LINE AND - ; • •r 'Disconnect is Located: ' '`. Inte�oc'"—=, N NYSERDA LOAD SIDES MAY BE ENERGIZED _ _ _ Baserneht Ga9e_.-1: t?r!4�;= ;I 4355: e -e ' __'Front:_n•'; INSTALLER i IN THE OPEN POSITION , Rear. 'LH Side:^_ . • ® ► NUMBER } i ^.RH_Side:- "Other Location; `__ PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE I _ - +r� '' ` j` EQUIPP ® WTH ► D JOB NUMBER WHENEVER THEY ARE EXPOED TO SUNUGHT SUNati`o n-Solar §ystems �� 631750�454<: _ wwwsunation_com' DOWN 20279 i I i I I i `il I N Ln j O I r N r N r N Z rn Y o 00 Z N O O +J (D E O pa) Cz U zC O C15 w o [C ;? U in ED M W 00 pl T I i E2= 1 PV LABELS • R-pp wR rl w�T X,!7- Jk "�l A, I Fisher Engineering Services, P.C. 509 Sayville Blvd- Sayville -New York 11782 Phone: (631) 786-4419 August 10, 2022 Attention: Town of Southold Building Department Subject: Engineer Statement for Solar Roof Installation Wilson Residence- 1785 Breakwater Road, Mattituck,NY 11952 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system(photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2020-Residential Code of New York State (2020 RCNYS), Long Island Unified Solar Permit Initiative (LIUSPI), 2017 National Electric Code,NFPA 70/2014, Weathering Severe, Wind Exposure Category B, Climate Zone 4A. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting,the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 140 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 2"x10" on 16" c.c., with an actual span of 16-5.75", 10'-7.5", 16'-7.5", with plywood roof decking and one roof shingle layer on the house as shown on the drawings. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, -/-J/ I F NEw p� William G. Fisher, P.E. Licensed Professional Engineer Architectural Design•Residential-Light Commercial Additions-Extensions-Conversions Construction Estimates/Oversight-Expediting-Inspections >a.. link : . �7 1 le LG375Q7 C=VS 375W LG NeON®R is powerful solar module that provides world-class performance.A new cell structure that eliminates electrodes on ---� the front maximizes the utilization of light and enhances reliability. LG NeON®R is a result of LG's efforts to increase customers values beyond efficiency.LG NeONO R features enhanced durability, ♦♦••`. performance under real-world conditions,an enhanced warranty ♦ ♦ - and aesthetic design suitable for roofs. ♦ • ' ewrawmewwucr . . • EVE OUS� C UL 25" .r. „re r. :IR WARRANTY Features Aesthetic Roof Extended Product Warranty LG NeONO R has been designed with LG has extended the product warranty aesthetics in mind:the lack of any of the NeON®R to 25 years,which is electrodes on the front creates an top level in the industry. improved,modern aesthetic. Enhanced Performance Warranty More generation per square meter „M" r The LG NeONO R has an enhanced The LG NeONO R has been designed to performance warranty.After 25 years, significantly enhance its output,making LG NeON®R is guaranteed at least it efficient even in limited space. 90.8%of initial performance. When you go solar, ask for the brand you can trust: LG Solar ................................................................................................................................................................................................................................................................................................................................................................................... .......................................................................... . About LG Electronics Aoft LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked on a solar energy source research program In 1905,supported by LG Group's vast experience in tiee semi-conductor,LCO,chemistry and materials industries In 2010,LG Solar successfuliv released its first MonoVP series to the market,which is now available in 32 countries.The NeONO(previous MonoXe NeON),NeONO2,NeONO2 BiFaciai won the"Intersolar , AWARD"in 2013,2015 and 2016,which demonstrates LG's teadership and Innovation in the solar industry Life s Good LG NeONOR LG375Q1 C-V5 General Data Electrical Properties(STC*) CeRPropertfes(Nlateravrype) Monocrystaiiine/N-type LG375Q1`c-V5 ................... .......................................................................................... ...................... ............ .................................................................................................................... LG :Maximu vawirl�pmax)..: 375 ................................................................................................................................. ........... ............................................................................................................ .......... 60 Cells(6 x 10) .!!1PPVb1�!Le1 37.2 ..................................................................................I...................................... ............................................................................................................ 1.700mm x 1,01 6mm x 40mm I MpP q 10.09 4"ut(TP??-L �J.111�11................................................................................................................................:.': .:.; .........................;.................................................................................. ...... ............... 7- ........ Open circuit Voltage(Vocit 5%) M 42.8 17.5 kg .................. ................................................................................................................ Glass ifi�ciuie�. i8mm/Tempered Glass with High Transmission Sh6rtCircuitJbunrintQsc�ts%) (A) 10+83 Anti-Refle .............. .............................................................................................................................. ctive Coating ............................ .......... ............................................................................................................ 21.7 Moduli Effi 'Backsheet(Color) White ...... ...... ............ ............................................................................................................ ---0............................................ ................. —3 Frarre(Material), Anodized Aiuminium ................... ......................... ............................ ................................ *STC(Standard Test Condition),Irradiance 1000 W/M2,Cell temperature 25*C,AM 1.5 )unction Box(Protection Degree) IP68 with 3 Bypass Diodes ........................................... -7-71............................................................................................................ **Measure Tolerance:t 3% Cables(length) 1,000mm x 2EA Coinniictor(Type/Maker) MC4/MC — Certifications and Warranty Operating Conditions 00 ratiri Tenu IEC 61215-1/-1-1/2:2016,IEC 61730-1/2:2016, ne -40-+90 ............................................................................................................. UL 1703 Maximum 1,000 Certifications: ..................................................................................................... ISO 9001,ISO 14001,ISO 50001 Maximuni series Nse Rati 20 ............................................................................................................ OHSAS 1800 1 Mechantcal[T..I"ad(Froint) 5,400/113 ................. ..................................... ............................................................ ut Mistcarrosion Test EC 61701:2012 Severity 6 MechanlcalTkM56d(Rear) +1 [Ipa/psf3 4,000/83.5 ................................................................................................... .....................................................................L.............................................................................................................................. Ammoniacorrosiiin*last IEC 62716:2013 -2:2016 ......................................................................................................... Mechanical Test Load 5,40OPa/4,00OPa based on IEC 61215 Moduli Fire Performance (Test Load-Design Load x Safety Factor(1.5)) : Type 1(UL 1703) .............................................................................................. Fire Rating Class C(UL 790,ULC/ORD C 1703) . . ................................................................. ProductWarranty 25 Years ............................... *...........................- - ***** -***** ****..... ...................... Output Warranty of Pmax :: ���- Linear Warranty* . .................. ................................................ ..........; ............................................................................................................ *Improved.I st year 98%,from 2-24th year:0.3%lyear down,at 25th year:90.8% Packaging Configuration ..Number of Modules per Pallet :J i JEA] 25 �-i 1.-�--------.--.- t........................ ............. ...................................................................................................... Temperature Characteristics jNui6iecif Modules per 650 NMOT. 44 3 Packa§IfijB6xDinmftons(Lx,WxH).. Cram] 1,750 x 1,120 x 1,221 ....................... .................................. ........................................................................................................... . . . Pmax l%J-CJ -030 Packaging Box Gross Weight [kg] 473 .......... ................................................................................................................... �Voc -0.24 l%PC1 �.............. .................................................................................. ........................... Isc, [%PC] 0.037 -NMOT(Nominal Module Operatinglemperat.rey Irradiance 800 W/m,Ambient temperature 20°C, Wind speed 1 m/s,Spectrum AM 1.5 Dimensions(mm/inch) Electrical Properties(NMOT) Model LG,37SQ1C-VS ,-- -:::-7 :............................................... ....................................--r..;.............. IMMmum power(Pmax) 282 175. 40.0/1.57 M :1 37.1 MPPVottage(Vmpp) ...................................................................................................................... G rounding Holes 7.61 .......... 1111�5 2 Q1 open Circuit Voltage(Vqc). IV] 1 403 ; Short Circuit Current(lic) (A) 8.72 IN Curves 1000.0/39.i Cable Length 0 o- 8 oc- 0 6.0 ...600VI........................................... J I 4WW 40 2.0 ............................ 1 m m c; 7 c; 0.0 D a 210.0 30.0 40.0 Voltage Ili LG Electronics,Inc. I Product specifications are subject to change without notice. W'K IN Solar Business Division LZ375Q1 C-V5.pdf 2000 Millbrook Drive LG Lincolnshire,IL 60069 Lifers Good al.Q. MWIg-solancom ©2020 LG Electronics,Inc.All rights reserved. • ENPHASE. m IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC Easy to install power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple �— two-wire cabling Enphase e High productivity and reliability 25 • Produce power even when the year limited i grid is down 6 warranty More than one million cumulative Part of the Enphase Energy System,IQ8 Series I08 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming CERTIFIED Complies with the latest L SAFETY advanced grid support Connect PV modules quickly and easily to I08 Series Microinverters are UL Listed as Remote automatic updates for I08 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements I08SP-DS-0002-01-EN-US-2021-10-19 IQ8 and IQ8+ Microinverters INPUT 1ATA(OCI 108-60-2-US1" Commonly used module pairings' w 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current'[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT 1A A .1 A Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit4 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency / 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -400C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-0222 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19 SERIES 100 FLASHED L FOOT SnapNrackRes,iderAial PV MouSystems The SnapNrack line of solar mounting y ..., r a a.4.w-• _<.xS�>-_-.-':_'.;--;-'_ 40;::''sg,'r.S t: ,f,,�z=�s.,`..s'""'-'-_'•G,c:..,4s ��,,.Y�,:,.c`a,,,".r'6„ ,4-4_ _y`. .r-.-v. _ �='z-. yy%S .. �,x'F' i•a f T. r ':Yy 2�7�?�:-r ir'"�.,?. '>zu systems is designed to reduce total --+'.zfi�r'..y- -� u.cs. z ^q,t, %`F..::•. :��r-0.6'��,� �'2z}*..J.;O� installation costs.The system features ' technical innovations proven on more than 200MW of solar projects to simplify installation and reduce costs. •+. �4'St,�..� +rya Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a w^ ^_ single fastener flashed to.an attachment composition Flashed L Foot in 3 Simple Steps: shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www.snapnrack.com/contact SnapNrack- Patent Pending n 1 1 . i 1 i Flashed L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1'spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions F-SNAPNRACK CHANNEL NUT ,-SNAPNRACK 92 DEGREE L-FOOT,CLEAR r 513618 FLANGE NUT O j SPLrr LOCK IIN KWASHE WFfH SPLIT IOCIC WASHER -SNAPNRACK COMPOSMON FLASHING 4' I 3.13 - -SNAPNRACK L-FOOT BASE Jis SnapNrack Flashed Foot TechnicalData Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapNrackl PM Vk� o unting Sys�e s (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. S S• • • UL ROOF MOUNT SnapNrack •lar Mounting Solutions The SnapNrack line of solar mounting - solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation `` - quality on more than 350 MW of solar - installations. Pitched Roof Arrays Simplified v: :xR ;ti i °.q The SnapNrack Series 100 UL Roof Mount System •t �lif'•r�'i::r"f£i.�y4':FA'.�Yi.+: :?'�.Lc f�f;yy??,."•is an efficient,visually appealing, photovoltaic(PV) _�; ��:n.•,_„_-t;:�°;��.� �•�-� module installation system.Series 100 UL is Listedto the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for ROOF System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type,Wind and Snow Loads) the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material.for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules u`. LISTED PV mounting System Patent Pending 2703 U w Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Stainless Bolt with Bolt with Split- Splice Insert Split-Lock Washer Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrack Splice Clamp Top Bonding Base Mid Clamp � SnapNrack SnapNrack Bonding 'r Bonding SnapNrack Stainless Adjustable End Channel Nut Bon Clamp Bottom ding Stainless Hardware with Bolt with Channel Nut Split-Lock Washers Split Lock SnapNrack Bonding Washer Adjustable End Clamp SnapNrack Bonding SnapNrack Bonding Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG - Copper Wire — • SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF ���� • MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave � UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer IF IF IV ly IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff i Clamp Assembly SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack Stainless SnapNrack 'ram` 92 Degree Flange Mill Finish Bolt Standoff L Foot SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shown) o SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Standoff Assembly L Foot Base with Flashing Roof Base with Bonding L Foot Patent Pending SnapNrack Series • • UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to LIL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship(download full details at snapnrack.com) SnapNrack- Solar Mounting Solutions (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved.