HomeMy WebLinkAbout50774-Z TOWN OF SOUTHOLD bra ll BUILDING DEPARTMENT p r# TOWN CLERK'S OFFICE SOUTHOLD, NY a BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS. UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50774 Date: 6/3/2024 Permission is hereby granted to: Brown, Nadia 52 Pamela Rd Cortland Manor NY 10567 To: Install an accessory generator to an existing single-family dwelling as applied for per manufacturers specifications. At premises located at: 1525 Greenway E, Orient SCTM # 473889 Sec/Block/Lot# 15.-1-12 Pursuant to application dated 4/22/2024 and approved by the Building Inspector. To expire on _mm 12/3/2025. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $125.00 CERTIFICATE OF OCCUPANCY $100.00 ELECTRIC $100.00 . .................................................................._...... Total: $325.00 Building Inspector y r TOWN OF SOUTHOLD—BUILDING DEPARTM T Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 htt :1fw . oytoidtowr►I .'ta Date Received APPLICATION FOR BUILDING PERMIT r For Office Use Only � ,I PERMIT NO. Building Inspeor: i aT Applications and forms must be filled out in their entirety.Incomplete - applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date.. ,..m 70T OWNER(S)OF PROPERTY: Name:Christopher & Nadia Brown SCTM#1000-15-01-12 Physical Address: 1525 Greenway East, Orient NY 11957 Phone#:917-698-0008 Email:christopherjbrown75@gmail.com Mailing Address: 1525 Greenway East, Orient NY 11957 CONTACT PERSON: w Name:Constantine Rigas Mailing Address:22260 Main Road, Orient NY 11957 a= Phone#:917-509-8751 Email:c@rigasco.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:Constantine Rigas Mailing Address:22260 Main Road, Orient NY 11957 Phone#:917-509-8751 Email:c@rigasco.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: R Other GENERATOR $7,000 Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes ii No 1 PROPERTY INFORMATION Existing use of property:Single Family under construction Intended use of property:Single Family W/generator Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes N'No IF YES, PROVIDE A COPY. ® Check BOX After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 230.4S of the New York State Penal Law. Z^ Application Submitted �y(print n �e): \ k Authorized Agent ❑Owner Signature of Applicant: Date: D.BUNCH STATE OF NEW YORK) Not1'�A.INIE F" blil� State of New York No.01 BU6185050 SS: Qualified In Suffolk County G COUNTY OF ) Commission Expires April 14,2-o being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this f day of / 20 Notary Public PROPERTY OWNER AUTHORIZATION (see separate authorization) 2 Building Department Application AUTHORIZATION here the Applicant is not theOwner) I. Chrivopher Brown, owner of 1525 Csreeniray East. Orient ATI1 57 do hereby authorize Constantine Rigas to apply can my behalf to the SoutholdBuilding epa ent for all necessary permits. r w-ner ign turc) (Date) (Print er"s e) � BUILDING DEPARTMENT- Electrical Inspector �� " ^ TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 p ( ) 802 - FAX (631) 765-9502 Telephone 631 765-1 . µ* amesh southoldtownn ov sea nd southoldtownn qv APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORM A TION (Au I oration Required) Date: Company Name: "% , Electrician's Name: t - License No.: Elec. email: Elec. Phone No:U I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: Cross Street: Phone No.: Bldg.Permit #: 5 D email: Tax Map District: 1000 Section: 15 Block: Lot: I ELi BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly). Square Foota e: Circle All That Apply: Is job ready for inspection?: •-''YES F—] NO Rough In El Final Do you need a Temp Certificate?: YES[:] NO Issued On Temp Information: (All information required) Service Size Ell Ph[]3 Ph Size: A # Meters Old Meter# nnect Service Reconnect Underground❑Overhead ❑New Service❑Fire Reconnect❑Flood Reco ❑ ❑ # Underground Laterals 01 2 0 H Frame Pole Work done on Service? I Y N Additional Information: PAYMENT DUE WITH APPLICATION 5 br]�� ` ^ GENERAC 11W Residential Standby Generators Air-Cooled Gas Engine . , ` . Standby Power Rating � INCLUDES: aomo38'1.en07o39'/.Gumo38-3.eu07o39-3(Aluminum'Bisque)'zowv6m*z a��� o��� a��� e�m� 'm��'�mw�xz � �u Pmwm~ E�o�od�o�o�y ' enu�o�o'eummu� (Aluminum-----� Bisque) 24xw60*z 0 Two-line multilingual digital LCD6m|uUuo~controller ---~ ([o0|i»h/Spunioh/Fmnoh/Puruguoe) 0 2O0 amp service rated transfer switch available — 41 Electronic governor • Standard Wi'Fim connectivity • System status&maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector � • Natural gas mLP gas operationGENERAC 40 5 Year limited warranty 0 Listed and labeled for installation uu close uu10in(457mm)toa *mmum.~ ' % *Must be located away from doors,windows,and fresh air intakes and in x�o�n�����m�m ' ' mn@us QUIET—TEST. ����� C����'"° LISTED ^~~ ^ ^ ~~~~ ^~ "�� ]P ~=~ CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are Eumm certified in the USA only. FEATURES o INNOVATIVE ENGINE DESIGN& RIGOROUS TESTING are m the heart of Gen' D n0UD'8TATE. FREQUENCY COMPENSATED VOLTAGE REGULATION: This eram'o success in providing the most reliable gonon�� poon|No. Gonomo'uG' omm�AA��pmwmmmimidngmgu|�oo�momio�m��on� �m|GnnmoU' �m � m 000gino|in000 � added pemo�mi�and m|i�i|ityfor when it's needed o|o.K provides optimized FAST RESPONSE m changing load conditions and MAXI- the mom.TkoG-Fompoori000nginesumpurpmmUui|tanUUnoignoUto handle the MUM MOTOR STARTING CAPABILITY Uy electronically torque-matching the surge rigors of extended run times io high temperatures and extreme operating conditions. loads m the engine.Digital voltage regulation m.0%. o TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave o SINGLE SOURCE SERVICE RESPONSE from ounomu',extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides pans and service know-how for the entire unit,from the engine to the small- allows con8Uomoponminnof sensitive electronic equipment and micro-chip based ust electronic component. appliances,such m variable speed HVACsystems. O TEST CRITERIA: 0 GEN[RAC TRANSFER SWITCHES:Long life and reliability are synonymous with GENE��PmN�RSYST �G One m�un�r�iomnhduo�io���oGENE�C / PROTOTYPE TESTED / N�����1'%8�VAL��'|�N SYSTEMS. / SYSTEM TORSIONAL TESTED / MOTOR STARTING ABILITY product line io offered with its own transfer systems and controls for total system ' compatibility. o MOBILE UNKO' CONNECTIVITY:FREE with select Guardian Series Home standby Uonomtom, Mobile Link Wi'F|allows users m monitor generator status from any- where intho*mr|UuoinVoomu okone.mb}nt,orpC.Bmi|yuncessinfonmuonouch as the current operating xmmo and maintenance umnu. Uoom can connect an account mun authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. ` ` `U G E N E R A C �c| t������K���V +-|pQOMSE `Z...-7 � ' r GENERAC® 20/22/24 MY Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Snitch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. .• Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution'" Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5'seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. ;r GENERAC® 20/22(24 kW� Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector , Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • ,Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local'ambient weather conditions for generator location. GENERACO 20/22/24 kW/) Specifications (generator Made[ G00703B-1 G007042-2 G007038-3 G007042-3 GOQ7.209.0., G007039-1 G007043-2 0007039-3 G007043-3 �/6007210- (20 kW) (22 kW) (20 kW) (22 kW) -11-17flK Rated maximum continuous power capacity(LP) 20,000 Watts' 22,000 Watts' 20,000 Watts` 22,000 Watts" 24,000 Watts- Rated maximum continuous power capacity(NG) 18.000 Watts' 19,500 Watts` 16,000 Wads' 19,500 Watts' 21,000 Watts' Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 63.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 ' Total Harmonic Distortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA minimum or Group 95AGM 650 CCA minimum Unit weight(lb/kg) 448/203 466/211 436/19B 445/202 455/206 Dimensions(LxWxH)In/cm 48x25x29/121.9x63.5x73.7 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load" 67 67 67 67 67 Sound output in dB(A)at 23 It(7 m)with generator in Quiet-Test`"low-speed exercise mode" 55 57 55 57 57. Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx.1.9 qt/1.8 L Operating rpm 3,600 Fuel consumption Natural gas 113/hr(m3/hr) 1/2 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) Full Load 301(8.52) 327(9.26) 2B7(8.13) 306(8.66) Liquid propane ON(gal/hr)Whr] 1/2 Load 87(2.37)[8.99] 92(2.53)[9.57] 86(2.36)[8.95] 92(2.53)[9.57] Full Load 130(3.56)[13.48] 142(3.90)i14.77] 136(3.74)114.151 142(3.90)114.77] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply dsPor x 2500(LP)or d/hr x 1000(NG).For Megaloule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/AlarMMaintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Faull/Missing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).`Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megaloule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 it(304.8 m)above sea level;and also will decrease approximately 1%for each 10'F(6'C)above 60°F(16°C). GENERAC' 20/22/�24 kW Switch Options Service Rate'd�W atic Transfer Switch Features G007039-1,0007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. Model G007043.2,G0070434(22 kW) _ G007210-1(24 kW) • Up to eight additional large(240 VAC)loads can be managed when used in conjunction No.of poles 2 with Smart Management Modules(SMMs). current rating(amps) 200 • Electrically operated,mechanically-held contacts for fast,clean connections, voltage rating(VAC) 120/240,10 • Main breakers are rated for 80`yo continuous load. Utility voltage monitor(fixed)* -Pick-up 80% r p • 2-pole,250 VAC contactors. -Dropout 65% • Service equipment rated,dual coil design. Return,to Utility` Approx.13 sec ETL or UL listed Standard • Rated for both aluminum and copper conductors. Enclosure type, NEMA/liL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range' 250 MGM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly 200 Amps 120/240,1® Open Transition Service Rated 7i Height Wig Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 i cm 1 67.95 76.43 26.67 34.18 17.5 H2 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 L DEPTH-I L-12� GENERAC® 20/22y24 kW) Available Accessories _ Model# Product Description Gd07101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0 IF(46 nC).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0 IF(-18°C). G007103-1 Breather Warmer Breather warmer is for use In extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be. Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Klt The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured (Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is Important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G606485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G667605-0 Wi-Fi LP Tank Fuel Level The Wi-F enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. 13007169-0-413 LTE Mobile Link'Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-WI-FV Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of alr-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC 637.e mm 1215 mm [25.7 In] [43•0 In] G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 7�gs*nm G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 101 G007209-0 696471071511 13007210-f` 1 696471084801 51n1 '[4B 6'In LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installatlon manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RAC" Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189• generac.com — Pry ©2021 Generac Power Systems,Inc.All rights reserved.Ali specifications are subject to change without notice.Part No.A0000937e14 Rev.0 04/14/2021 r r YZD /WIF ► LNG' PASS• � TASK,'0 9 �;1'S •6� � 5LA'� :�' 1 g.6'V`1 0.0 GpXC,. PPSa m pOL i� 17R EGZVIP• GFL 5 // { ��3. Q t1i I-FL 5TI C- 0 _ B -LPI 5T2 L,Qt '4 iW Oo � 5ubdivt5lpn /"01 Ln 116roOn Aores LP2 qt Qrlfht Di rn 0 0