HomeMy WebLinkAbout49788-Z EFQ1k�OG Town of Southold 2/16/2024 y� P.O.Box 1179 0 y - 53095 Main Rd 4; o ,?' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44990 Date: 2/16/2024 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1820 Wells Ave, Southold SCTM#: 473889 Sec/Block/Lot: 70.-3-20 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/7/2023 pursuant to which Building Permit No. 49788 dated 9/27/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Calvo,Agustin&Romo,Melissa of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49788 12/15/2023 PLUMBERS CERTIFICATION DATED Author'zed Ugnature o�SUFFec,r�o TOWN OF SOUTHOLD BUILDING DEPARTMENT H x TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49788 Date: 9/27/2023 Permission is hereby granted to: Calvo, Agustin 812 Grand St Apt 219 Hoboken, NJ 07030 To: Install roof mount solar to existing single family dwelling as applied for. At premises located at: 1820 Wells Ave, Southold SCTM #473889 Sec/Block/Lot# 70.-3-20 Pursuant to application dated 9/7/2023 and approved by the Building Inspector. To expire on 3/2812025. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-RESIDENTIAL $50.00 Total: $200.00 Building Inspector pF SDUj�Olo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 ��l� �o sean.devlin(g�town.southold.ny.us OOUNT`I BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Agustin Calvo Address: 1820 Wells Ave city,Southold st: NY zip: 11971 Building Permit#: 49788 Section: 70 Block: 3 Lot: 20 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: GreenLogic License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 10.8kW Roof Mounted PV Solar Energy System w/ (27) SunPower SPR U 40OW Modules , AC Disconnect, AC Combiner Notes: Solar Inspector Signature: Date: December 15, 2023 S.Devlin-Cert Electrical Compliance Form SOUIyp� V1 �] � D - # TOW OF'SOUTHOLD BUILDING EP . `yCrourm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Ack �-4 , 4- _ i c DATE t2— 1S INSPECTO OF SOGTyo� TOWN OF SOUTHOLD BUILDING DEPT. �O • oou io rm,��'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [� FINAL �o%L [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION /[ ] PRE C/O [ ] RENTAL REMARKS: lk c 0/0 1M DATE INSPECTOR i G RisG L ANE E As. T NO. RTHn .0RT N. Y., aa,i -- a, 5a ea, a. B Post Installation Letter November 21, 2023 RE: Romo Residence 1820 Wells Ave, Southold, NY 11971 Permit#49788-Issued: 9/27/23 SCTM: 70-3-20 To Whom It May Concern: This letter is to confirm that as of this date November 21, 2023, I, James J Stout, NYS license 021633 have inspected the placement and installation of the roof top solar panels at the above listed address. The solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2020 NYSRC and provisions of ASCE 7-16. The installation was done as per approved Building Department plans, This certification letter must be presented to the municipality within 120 days of the issuance date to ensure compliance with safety procedures and continuity of service, Thank you for your cooperation in this matter. James J. Stout C�NCO S / 0,2 :ELD INSPECTION REPORT DATE COMMENTS "0 FOUNDATION (1ST) -------------------------------- O � FOUNDATION (2ND) z 0 CP N G \3 ROUGH FRAMING& ,� PLUMBING 1 N INSULATION PER N.Y� STATE ENERGY CODE OA FINAL ADDITIONAL COMMENTS S 9�1`r?�1-1. sz� m a W H_ N O .. z x H x d b H �� Foa TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 httl)s://www.southoldtownny.Pov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D E C OWE PERMIT NO. O Building Inspector: SEP ' 7 2023 Applications and,fcirms must,6e,hlled.out iri their entirety..Incomplete,, applications willnot•.be accepted. Where.the Applicant is not the owner;an , Building Department Owner's Authorization form(Page 2)shall be completed.. Town of Southold Date: 8/7/2023 ,OWNER(S)OF PROPERTY Name:Melissa Romo SCTM#1000-70-3-20 Project Address:1820u Wells MAvenue, Southold, NY 11971 ..._.... .............. .._.._ . .. ..._.__...__.........._._...._._.. _...__.. µPhone#:201-401-6238 7Email:melissatromo gmail.com Mailing Address:81_2 Grand St, Apt 219, Hoboken, NY 07030 CONTACT PERSON: Name:Barbara - GreenLogic„LLC Mailing Address:97 North Sea uRoad, Southampton, NY 11968 Phone#:631-771-5152 x117 Email:Barbara-@,Greenlogic,com_ QESIGN PROFESSIONALINFORMATION: Name:James J. Stout Architect & Associates Mailing yAddress:2 Greg Lane, East.Northport, NY 11731 Phone#:631,-85.8.-9388__... Email:stouthub.0iamesstoutarch.com„„ ..CONTRACTOR INFORMATIONc' Name:GreenLogic.LLCr. _ __..__......_.._.... _......___........._,......._._. . ..._.__.._........ ._.. ..._.__.. . .._..... _ ._.__ ._._.__. ____ Mailing Address:97 North_Sea Road, Southampton, NY 11968 Phone#:631-7715152 _..m. _., _ _._m_-.._... . _. Email:AMGreenlogiccom I,IscRlPTioN of PROPosED cPNSTR, CTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: lilother Solar Panels $ 39,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes [60 IF YES, PROVIDE A COPY. ;B:Check BOX`AftL'r,ReadliBg:°"The ovirnerJcontractor/design oral is responsible for,all drainage and storm water issues as provided by Chapter 236 of.the Town Code.'APPLlcATl0N;IS,HEREBY MADE,to the Building Department for the.issuance of a Building,Permit pursuant to the Building Zone i'Ordinance of the Town of Southold,°Suffolk,County;New York arid.other applicable Laws,Ordinances of Regulations,for the construction-of Buildings, additioris,alterations orfor removal or demolition as herein described.The applicant agrees,to comply with all a0plica6l0aws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premi'esg and5in building(s)for necessary inspections:False state merits made Herein are punishable as a Class A inisdemeanoupursuantto Section 210AS of the(dew York State Penal,ow..' ' Application Submitted By(print name):GreenLogic LLC ®Authorized Agent downer Signature of Applicant: Date: St 5t 3 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Ne.sim Albukrek being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this a5 day of , 20 01,5 hwtht, VA�qkiw-, Notary Pub64BARAACASCIOT rA, Mary Public-81me of Now Ybik' NO.OICA4894969ed In Co *' PROPERTY OWNER AUTHORIZATION Cemf1 mExpr siftalk l 11.2 ��y � (Where the applicant is not the owner) residing at 6WA (62-0 U)-d -Ayv- do hereby authorize GreenLogic LLC to apply on my behal the Town of Southold Building Department for approval as described herein. * , Z 212n3 Owner's Signature Date Print Owner's Name' 2 VaF044/er BUILDING DEPARTMENT- Electrical Inspector Q �!✓, TOWN OF SOUTHOLD - Town Hall Annex - 54375 Main Road - PO Box 1179 r "' Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr southoldtownny.gov-- seand(a)-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8/29/2023 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: BarbaraCGreenlogic.com Phone No: 631-771-5152 ❑I request an email copy of Certificate of Compliance Address.: , 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Melissa Romo Address: 1820 Wells Avenue, Southold, NY 11971 Cross Street: Phone No.: 201-401-6238 Bldg.Permit#: Lf q-7:j:�" email: melissatromo@gmail.com Tax Map District: 1000 Section: 70 Block: 3 Lot: 20 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (27) SunPower SPR-U-400-BLK panels Et (27) Enphase IQ7HS micro inverters (1) SunPower PVS6 monitor System Size: 10.800KW Check All That Apply: Is job ready for inspection?: DYES ❑✓ NO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: ❑✓ YES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.x1sx Vv l SURVEY -Of PPOPEPTY 51TUATE: 5OUTHOLD ®� TOWN: 5OUTHOLP E I SUFFOLK COUNTY, NY SURVEYED 10-02-2020 S SUFFOLK COUNTY TAX# 9 1000-10 -3-20 -� C;l1RTEO TO:hMM i ROMO AGUS I CALV fi r AOIJST1Pt CALd®R®M® OLIDA)BP MUC TITIZ CO. Pq V9\ -� � Q� 0 -O Ai J Q x o Q t r(n) O. x r• • x I I p m�� x Q O A DR LT IVEWAY p� FFZ. 1' i p � SHED NOTES: },v -4 ����ce sa'nYtlssee!obv Wnb IL I • MONUMENT FOUND \ 50UTHOL uN x.,•.n. u+xnue,vol,,o i -o—o—o— voop FENCE y TOW -X-X—x— CHAIN LINK FENCE _ JOHN C. EHLERS LAND SURVEYOR Area = 21 S21 50 FT OR 0.64 ACRES 6 EAST MAIN STREET N.Y.S.LIC.NO.50202 6RAPHIC SCALE I"= 4O' RIVERHEAD,N.Y.11901 369-8288:Fax369-8287 , REF-C\LTsm\lobn\DmpboxVMOX2020-157.pro i GREENLOGICO ENERGY August 29, 2023 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Projectlnfo: Melissa Romo 1820 Wells Avenue Southold, NY 1000-703-3-20 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: Building Permit application with owner authorization Application for Electrical Inspection 2 Surveys of the Premises • 4 Engineer's Reports 2 Three Line Electrical Drawings 2 Spec.sheets of the solar panels/inverters • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, `Bwdfcvca exociotta Barbara Casciotta Account Manager Barbara@Greenlogic.com GREENL(� I�-1�1iC1.5 C�rj.njjgc.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S. Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 G R E E N LOG I C° ENERGY itIJ F E B - 2 2024 ` January 30, 2024 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Projectlnfo: Building Permit No.49788 Melissa Romo 1820 Wells Avenue Southold, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy after inspection? Please let me know if you have any questions about the installation. Sincerely, J3wdwna Cc6cia#tac Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC•www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S.Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 Aco CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) 01/2612023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER HAcr Nra Nicholas Zulkofske Brookhaven Agency,Inc. PHONE 639 941-4113 Fax N 631 941-4405 100 Oakland Ave,Ste 1 E-Mpg AIL Certificates@ brookhavena enc .com Port Jefferson,NY 11777 INSURERS AFFORDING COVERAGE NAIC# INSURER A: Southwest Marine&General Insurance Co. INSURED INSURER B: Merchants Preferred Insurance Co. GreenLogic,LLCI INSURERc: First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D: National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E. AGCS Marine Insurance Co. INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER MO DDY EFF MMLICY DD1 EXP LIMITS R X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000 000 A CLAIMS-MADE FX1 OCCUR DAMAGE TO REor NTED $10O 000 X Contractual Liability X X GL202300012922 01/3112023 01/31/2024 MED EXP(Any oneperson) $5 000 PERSONAL&ADV INJURY $1 00O 000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2 000 000 POLICY X�PRO ❑LOC PRODUCTS-COMP/OP AGG 2 000 000 JECT OTHER: E&O Liability $1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1 00O 000 B X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08/11/2022 08/11/2023 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY X AUTOS ONLY UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y I N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A see separate certificate (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under , E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS below C NYS Disability D251202 04/1112022 �04111112023 Statutory Limits E Installation Floater/Property, SML93076366 04/1512022 04/15/2023 $300,000 $2,500 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may he attached if more space is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <NSZ� @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD � R workers' CERTIFICATE OF INSURANCE COVERAGE STOA E Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured GREENLOGIC,LLC 631-941-4113 97 NORTH SEA ROAD,SUITE 3 SOUTHAMPTON,NY 11968 SOUTHAMPTON,NY 11968 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e., Wrap-Up Policy) 203801194 2,Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold Building Department 3b.Policy Number of Entity Listed in Box"la" 53095 Route 25 DBL251202 Southold, NY 11971 3c.Policy effective period 04/11/2022 to 04/10/2024 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 4/4/2023 By (W. (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board (only if Box 46,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number 'Name and Title 'Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) I (iiiiiiiiiiiiiiiii������ voRK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Greenlogic LLC (631)771-5152 97 North Sea Rd 1c.NYS Unemployment Insurance Employer Registration Number of Suite 3 Insured South Hampton,NY 11968 Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e., a Wrap-Up Policy) Number 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) United Wisconsin Insurance Company 3b.Policy Number of Entity Listed in Box"1a" TOWN OF SOUTHOLD WC605-00090-023-SZ BUILDING DEPARTMENT 53095 ROUTE 25 3c.Policy effective period SOUTHOLD,NY 11971 01/01/2023 to 01/01/2024 3d.The Proprietor,Partners or Executive Officers are ❑ Included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its-licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days'IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate,'holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Alicia Christiansen (Print name of authorized representative or licensed agent of insurance carrier) Approved by: ,�� ( �l1ZGd /2�20�1i IZZ ��ZZ (Signature) (Date) Title: Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 941-306-3077 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) www.wcb.ny.gov ",ire "As -y A— ........... Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE, NEWYORK 11788 J-)A I r, ISSUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY Home Improvement Contractor License I This is to certifv that MARC A CLEJAN doing business as GREEN LOGIC LLC having ftu-nished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York.is hereby licensed to conduct business as a HOME ... ........ IMPROVEMENT CONTRACTOR, in the County of Suffolk. Additional Businesses NOT VALID WITHOUT SEAL MR ) DJ�PARTMENTAL AND A CURRENT CONSUNIER AFFAIRS ........... ID C&RD Director 41, I Suffolk County Executive's Office of Consumer Affairs airs VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 DATE ISSUED: 12/10/2007 No. 43858-ME SUFFOLK COUNTY ,Master Electrician License � This is to certify that ROBERT J SKYPALA doing business as GREENLOGIC LLC ; I having given satisfactory evidence of competency, is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws, rules and regulations of the County of Suffolk, State of New York. �[ Additional Businesses I NOT VALID WITHOUT DEPARTMENTAL SEAL AND N CURRENT CONSUMER AFFAIRS II)CARD Director L MOM r APPROVED AS NOTED DATE OCCUPANCY • OR ..F e.P� FEE USE IS OD gY, UNLAWFUL ' NOTIFY BUILDING DEPARTMENTAT WITHOUT CERTIFICATE 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: OF OCCUPANCY I. FOUNDATION-TWO REQUIRED ^ FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE i' > �- REQUIREMENTSOFTHECODESOFNEW �o i��L°� WI-�`N,ALL: QDES 0k : YORK STATE. NOT RESPONSIBLE FOR ���Y®RIC STA''Ir&TOWN,CODE$ DESIGN OR CONSTRUCTON ERRORS AS REf UI ED ANL��':_ONDJT,16 �S,OF' 'SOUi 0TOWNM SOUTHOLD"TOWN PLANNINaWpR : .SOMOLD TOWN TRUSTEES N;Y.3 DEC­ Tam omme "FzQufm RETAIN STORM W APTER 2uNo36FF PURSUANT TO CH OF THE TOWN CODE. . e J A M E S J. S TOUT A R C H I T E C T & Assoc. 2 G RE L AN EAST NORTHPORT N. Y. 631 - 8 58 9388 Letter of Certification August 3,2023 RE: Romo Residence 1820 Wells Ave. Southold, NY 11971 To whom it may concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and complies with the 140-mph wind design load as per 2020 Residential code of NYS (RCNYS), 2020 Energy conservation construction code of NYS (ECCCNYS), the Long Island Unified Solar Permit Initiative (LIUSPI) and the ASCE 7-16. The existing 2"x'8" @ 16"o.c. roof rafters will provide the required support. Thank you for your understanding in this matter. James J. Stout Architect �f ARC3. f 21 �� �-SO AR ,r 3 3.- --^_________________NEW EQUIPMENT--- -----_ _ __ ________ i *,`- - * EXISTING SERVICE 240,12Q AC-COMBINER PANEL Q� 1 PH, 3W PV-SA-1 �-� 0 3 � AC-CMB-1 t�I • • • , (PV LOADS ONLY) t-- ;W)H I I I ................ ._...................._.. ........... rmn PV-SA-2 _ I • • AC-DSC-1 BKR-1 AC DISCONNECT ( + V I I ! I BKR-2 ° PV-SA-3F01. . . . N! . . . Z f I ( 8KR-3 'I i 1�l 6 l ' }---�MAIN i III BKR-4 + A B N I PV-SA-4FM j FUs�D • • • . . . 2 1 ! II N IF7 I i l I C N H TYPICAL PV MODULE WITH IIII I INTEGRAL DC/AC INVERTER II ' I EGC R EGC IIII I I IIII I I # I 10.800kW DC i j I i I i EXISTING AC PAN EXITING LI __-0_368kW AC __ �__ �__ L��-�®� ___—_L________________�___ GEC _ PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Romo, Melissa GREENLOGICO 1820 Wells Avenue ct ENERGY Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Romo-3LD1 Revision: 1 Revised: 5/12/23 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 SUB-ARRAY WAAREE WSMD-400 ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-2 SUB-ARRAY WAAREE WSMD-400 ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-3 SUB-ARRAY WAAREE WSMD-400 ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-4 SUB-ARRAY WAAREE WSMD-400 ENPHASE IQ7HS, 1-CIRCUIT OF 3-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS VOLTAGE MAX.AC TAG POWER, MAX VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3200 WATTS 211-264 VAC 13.00 A AC 240 V, AC PV-SA-2 3200 WATTS 211-264 VAC 13.00 A AC 240 V,AC �ti��a Aqe PV-SA-3 3200 WATTS 211-264 VAC 8.13 A AC 240 V, AC PV-SA-4 1200 WATTS 211-264 VAC 4.88 A AC 240 V, ACi. 'jyr 21 U3� yqQ bF NEB PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Romo, Melissa GREENLOGICO 1820 Wells Avenue ENERGY Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION - Page 2 of 3 Drawing No: Romo-3LD1 Revision: 1 Revised: 5/12/23 w a EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 25OV, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER�PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 100A, NEMA-1, FUSED; FUSE RATING: 100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 v B THWN-2 2" PVC-40 4 / 6 C THWN-2 2" EMT 4 / 6 1.) CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. �,E.O ARC 2.) ELECTRICAL CONDUITTO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. p ��\y��k /r;9•r 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. sr�gT 21, 33 yOQ i �bF NEB PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Romo, Melissa ct LOGIC" 1820 Wells Avenue ENERGY Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Romo-3LD1 Revision: 1 Revised: 5/12/23 A�'gP�C ABC __—_-_____--NEW EQUIPMENT-----------_-------------------- *, � ,. - EXISTING SERVICE PV-SA-1 A`> AC-COMBINER PANEL �j o e� 1201/140, Pt1, 'a'gr i y Z 163 y0 .... ......._........ AC-CM13-1 rF bF N6`� . . . '... N • • • 1 (PV LOADS ONLY) ' 200A (KWH) ..._........._.............. PV-SA-2 A�Fm I . • . A e N 1 :,C ter, . . . I AC-DSC- N I kBKR— AC DISCONNECT ! I I BKR-2 ' PV—SA-3FSFI . e e Fan —< o �`I e o • II BKR—3 a }�MAIN BKR-4 JFUSED PV—SA-4 ( � I a N IEGC t� N rrPtCAL PV MODULE WITH INTEGRAL DC/AC INVERTER I I EG(' IIII { EGC i flil I I � IIII I I � 1 10.800kW DC EXISTING ICISTING AC PAN IGE ING 10.368kW ACcu ----__ _ . PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Romo, Melissa E E N LOG ICo 1820 Wells Avenue ENFRGY Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Romo-3LD1 Revision: 1 Revised: 5/12/23 k EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 SUB-ARRAY WAAREE WSMD-400 ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-2 SUB-ARRAY WAAREE WSMD-400 ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-3 SUB-ARRAY WAAREE WSMD-400 ENPHASE IQ7HS, 1-CIRCUIT OF 8-MODULES PV-SA-4 SUB-ARRAY WAAREE WSMD-400 ENPHASE IQ7HS, 1-CIRCUIT OF 3-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3200 WATTS 211-264 VAC 13.00 A AC 240 V, AC PV-SA-2 3200 WATTS 211-264 VAC 13.00 A AC 240 V, AC ERA0 Aq PV-SA-3 3200 VVATTS 211-264 VAC 8.13 A AC 240 V,AC PV-SA-4 1200 WATTS 211-264 VAC 4.88 A AC 240 V, AC ;1 021633 y0� bF N�`� PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Romo, Melissa R E E LOG IC' 1820 'Wells Avenue ENERGYNmOF Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 3 Drawing No: Romo-3LD1 Revision: 1 Revised: 5/12/23 -—--—----- ___ ____ __ __ EXISTING SERVICE NEW EQUIPMENT 300A KWH ( 120/240, 1 PH, 3W (TYPICAL SYSTEM SCHEMATI. FINAL INSTALLATION MAY VARY, i REQUIRES LOCAL AHJ AND UTILITY APPROVAL) j I E , i PV=SA-1 A AC-COMBINER PANEL AC=CMB-1 T 2 1 (PV ONLY) B EXISTING EXTERIOR -� AC DISCONNECT FUSEDC11 FUSED TYP. PV ARRAY n j 100A �/ MAIN �l PV-SA-N A I A B N BKR-1 I N • • .• 2 1 150A 150A MAIN }- MAIN ---- . U- - I BKR-N BFB-1 TYPICAL P.V MODULE WITH I I AC DISCONNECT A B N A B N INTEGRAL DC/AC INVERTER BKR-M II � . II P II � I N II13 N N I I PM-1 I I EGC CF9 :��MBJ EGC MBJ EGC II I ' / MAIN AC DISTRIBUTION I AC DISTRIBUTION I NEW EGC -L- NON-CRITCAL LOADS) (NO I I #6CU ---- C T --- �--I ------- -N-CRITCAL LOADS) --- - -- ( -------J I ---- IRREVERSIBLE�------------- BOND, TYP, -� EXISTING1GEC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Romo; Melissa JaGREENLOGIC!G 1820 Wells Ave ENERGY SOUtI'IOId, NY 11971 2.) REVISED TO.REFLECT ASBUILT CONFIGURATION ILIMIKATING THE LOST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 1 of 4 Drawing No: ROMO-3LD2A Revision: 2 Revised: 12/06/2023 SYSTEM SUMMARY TOTAL KW RATING: (AC POWER) 10.368 (PV) TOTAL PV KW RATING: .(DC POWER) 10.800 (PV) QTY. COMPONENT SPECIFICATION SUNPOWER BRAND, MODEL: SPR-U-400-BLK-W-DC 27 PV MODULE: 400 W DC (NOMINAL), EACH ENPHASE BRAND, MODEL: IQ7HS-66-M-US 27 PV INVERTER: (INTEGRAL TO MODULE) 384.VA, 1.60 A, 240V AC, EACH Romo, Melissa REVISIONS 1820 Wells Ave LOGIC Southold; NY 11971 ENERGY 2.) REVISED TO REFLECT ASBUILT CONFIGURATION EEIMINJOIN G THE:COST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 2 of 4 Drawing No: ROMO-3LD2A Revision: 2 Revised: 12/06/2023 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-U-400-BLK-W-AC, 1-CIRCUIT OF 9-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-U-400-BLK-W-AC, 1-CIRCUIT OF 9-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-U-400-BLK-W-AC, 1-CIRCUIT OF 9-MODULES PM-1 PRODUCTION MONITOR SUNPOWER PVS-6 AC-CMB-1 AC COMBINER PANEL, CRITICAL LOADS 250V, 100A, NEMA-1, 1-PH, 3-WIRE BKR-1...BKR-3 CIRCUIT BREAKER, PV-SA-1...PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-M CIRCUIT BREAKER, PM-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BFB-1 AC DISCONNECT BREAKER (GRID TIE) MATCH MAIN PANEL BRAND, CIRCUIT BREAKER RATING: 60A, 2-POLE REVISIONS Rom, Melissa 1820 Wells Ave G GRLOGIC Southold, NY 11971 EiVER:GY 2.) REVISED TO REFLECT ASSUILT CONFIGURATION :ELIMINATING THE:C.OST OF ENERGY 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 3 of 4 Drawing No: ROMO-3LD2A Revision: 2 Revised: 12/06/2023 ELECTRICAL LOAD SUMMARY,AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3,456 WATTS 211-264.VAC 14.40 A AC 240 V,AC PV-SA-2 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC PV-SA-3 3,456 WATTS 211-264 VAC 14.40 A AC 240 V,AC CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A NMB 3/4" PVC-40 10 / 10 B THWN-2 1" PVC-40 6 / 10 C THWN-2 1" PVC-40 12 / 12 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MINIMUM PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS-TO COMPLY WITH NEC AND LOCAL CODE REQUIRMENTS. 4.) NOTE: EQUIPMENT GROUNDING CONDUCTOR TO BE#6 COPPER, MINIMUM PROPOSED ELECTRICAL LOADS Romo, Melissa REVISIONS 1820 Wells Ave C+GREEINILOGI'C� Southold, NY 11,971 ENERGY2.) REVISED TO REFLECT ASBUILT CONFIGURATION ;ELIMINAbNIG THE COST OF ENERGY. 1.) INITIAL SUBMITTAL WITH PV APPLICATION Page 4 of 4 Drawing No: ROMO-3LD2A Revision: 2 Revised: 12/06/2023 LOG ICO ENERGY GreenLogic,LLC Approved Romo,Melissa 1820 Wells Avenue Southold,NY 11971 Surface#A: Total System Size:10.800kW Array Size:10.800kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:256° Pitch: Monitorinrin g System: SunPower Panel/Array Specifications: Panel:SPR-U-400-BLK-W-DC Racking:SunPower Invisimount Panel:75.7"X 40.8" o Array:57'3 3/16"X 10'3 15/16" Surface:61'2"X 18' Magic#:Invisimount Legend: ® 27 SunPower 350W Panels ®-- SunPower Invisimount Rail • 72 Iron Ridge Flash Foot 2 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: O� Aqc 5� 1. C1 T Drawn By:MMB Drawing#1 of 5 Date:7/25/2023 REV:A Drawing Scale:1/8"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Romo,Melissa 1820 Wells Avenue Southold,NY 11971 Surface#A: Total System Size:10.800kW Array Size:10.800kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:256° Pitch:20* -list Monitorinrin g System: SunPower Panel/Array Specifications: Panel:SPR-U-400-BLK-W-DC Racking:SunPower Invisimount Panel:75.7"X 40.8" o Array:57'3 3/16"X 10'3 15/16" Surface:61'2"X 18' Magic#:Invisimount Legend: ® 27 SunPower 350W Panels ® SunPower Invisimount Rail • 72 Iron Ridge Flash Foot 2 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: J� A�� / s% r Drawn By:MMB Drawing#2 of 5 Date:7/25/2023 1REV:A Drawing Scale:1/8"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Romo,Melissa 1820 Wells Avenue Southold,NY 11971 Surface#A: Total System Size:10.800kW Array Size:10.800kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:256' Pitch: Monitorinrin g System: SunPower Panel/Array Specifications: Panel:SPR-U-400-BLK-W-DC Racking:SunPower Invisimount Panel:75.7"X 40.8" Array:57'3 3/16"X 10'3 15/16" Surface:61'2"X 18' 3 Magic#:Invisimount Legend: ® 27 SunPower 350W Panels 2 SunPower Invisimount Rail • 72 Iron Ridge Flash Foot 2 1 H 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Iron Ridge,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: vkEl)ARC Ar iAr1 ti 33 yOQ� _ Drawn By:MMB Drawing#3 of 5 Date:7/25/2023 REV:A Drawing Scale:1/8"=1.0' No Vent Pipes Will Be Covered By The Solar ArrayG� I ° ENERGY Legend: GreenLogiq LLC Approved AR-Access Roof AP-Access pathway, 36" minimum width SVO—Setback at ridge Romo,Melissa 1820 Wells Avenue per R202 definitions per R324.6.1 as per R324.6.2.1 Southold,NY 11971 Total System Size:10.800kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:256" Ise Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-U-400-BLK-W-DC Racking:SunPower Invisimount Panel:75.7",X 40.8", Magic#:Invisimount Legend: ® 27 SunPower 350W Panels ® SunPower•lnvisimount Rail AR • 72 Iron Ridge Flash Foot 2 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 —------------------------- ------------------ — SVO Height above Roof Surface: Meter SVO Materials Used:Iron Ridge,SunPower ----------------------------------------------- Added Roof load of PV System:3.5psf Engineer/Architect Seal: ?21 2�7 SunPower 0 anels Drawn By:MMB Drawing#4 of 5 Date:7/25/2023 REV:A Drawing Scale:3/32"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Romo,Melissa 1820 Wells Avenue Southold,NY 11971 Total System Size:10.800kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker JOB MATERIAL LIST -��- � Azimuth:256° ;...___._ _..__ ....__._._..._................... ._ .__.._....._. . .._:_.._._._...._ __. _... . _.__ Monitoring System: ...___._.. . _..._........_._.._ .-. .. ..__.._.__;.----....._,._... . _' SunPower Panel/Array Specifications: Panel:SPR-U-400-BLK-W-DC Racking:SunPower Invisimount _......__............ .....__..,._..,._.. _ .._._,_, . ... _...._ _.... - ..._...... .__.__ _ Panel'75.7 X 40 8" Material List gt1L Rail Material List Magic#.Invisimount _....._..............._........... .. Legend: . ............ .. ............ _........................_._............_...:.................. .... .. ..................._................. ...... ® 27 SunPower 350W Panels ... ....... .......... _......_ .........._- ........__..................... :. ........... . ......... ........ ..........._..............._... SunPower Invisimount Rail ........................_...... .._._...._........_........._.... ..__.....__......................_.... ............. . .... ............................................................................................................................... ........_............_...€......__._....._....... ....................... .. Cast Aluminum Mounting Block w/Black Aluminum Flashing 72 • 72 Iron Ridge Flash Foot 2 5/16"x4.75"Hex-Head Lag Screw 72 2x8"Douglas Fir Rafter 16"O.C. __._ .._...._.__..._...__._..._._......__..... . _...._............._..... .._......_........._... _.. _.......... ...................._._ . _........ 5/16 x1.25 Fender Washer 72 Notes: _..._._...._........_....._.........._........._ ............ ...... _ ..... _.___._,_..,-............_. . ;_ ....__....... _ ._.....�__... __..__ _. ......._......._........... Number of Roof Layers:1 .._....... __..... ..._................._....... _.._.............. ..._.. .... ._........_ _. ._ Height above Roof Surface:4" ____.....__._ _._.,..___.._.._..._.._._,.__.,,__..__...__......__.......__ .___.__._ _._._ ._..._......._... _____._.._ . ....... Materials_......_...._... Materials Used:Iron Ridge,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: � t F iF 1 33 Drawn By:MMB Drawing#5 of 5 Date:7/25/2023 REV:A Drawing Scale:3/32"=1.0' a 1 • Q rNIN-MAIN . . • Simple and Fast Installation Try_ yf�w�.. r�>f.>�3,�:s`.9,,-_h* YJ. ,st"^�J..�.'.4:a`•___ _ `J Integrated module-to-rail grounding Pre-assembled mid and end clamps : =<r>, t, ,a• -``sz: �.4. .a<..: : :.: . _ ' ;c- �,�,u'g. ,,;'`' ;:Y•; "`, ":y,.�� art::'.��'-�`,Ps;`:ti,;,.: - Levitating mid clamp for ea placement J' Mid clamp width facilitates consistent,even module spacing- Simple,pre-drilled rail splice UL 2703 Listed integrated grounding I Flexible Design - Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management �^* Customer.-Preferred Aesthetics` 40 module arid#1 mounting aesthetics Best-in-class system aesthetics Elegant Simplicity Premium,lo,,v-profile design SunPower� InvisiMountT',' is a SunPovver-desi ned • Black anodized components g Hidden mid damps and end clamps rail-based mounting system. T he InvisiMol.;nt system and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System insti^alladon time:, design flexibility, and superior aesthetics. Built for use with SunPower DC and AC modules The InvisiMount:prodUCt:was specifically envisioned and Best-in-class system reliability and aesthetics Combine with SunPower modules and engineered to pair with SUnPower modules. The reSUlting monitoring app system-level approach will amplify the aesthetic and installation benefits for both Homeowners and installers. ��.• L (,�, iJ,fJlll ��. r ._a sunpower.com Datasheet fM r- • a i°�•• tir• �1 'r i iS :.r • r, r.s , .04 Li tTM SunPowerO InvisiMoun Residential Mounting System L9013 • Ivlcdtie*i Mid Clamp and Rail ;.ledule*i End C!amc and Rail ter Mid Clamp End Clamp Rai!&Rail Sp!!ce Ground Lug assembly :nd Cap ,w o I I • • • • s ! I ' rerr;oer'aau'e r'°C C'-'d C° to'94' _? Iat rI _....._......._...._...._.........Componen F:�i: - ........................._...._...._........... ........_ 3000 3 u t•:I,^ChJrn . ti „ - 61000 Pa do-,t'`IOrce r 'd Dt • e, «.. End Clamp Black anodized alurninurn alloy ui)u T6 11 C:g :1.88 oz) Rail Slack antxi!zcc1 alurninurn alloy!,005.'f;, 8:i{i: ,rr,)ni oJf!'} • Rail Splice AID onir:,•rn allay 6005.E 5 830:'m(9 o:;ft) 25.Year product warranty ----1' - --.._..----..---- ------- -._.... Ground Lug i ]:J�l Siail`!85 i ? .. ....__.._._._. .aG J .ues li S';!r:(i.'•5i 07.). .r. Syea ..rfin_ ..arfam Assembly fA -iu bolt tin-plated cuu..er alarl ! '• ` t._....._...---'--.._....._..........-- -------'--..........................._.._..__.....—................ __-___..._...............--.._._— ...._--'--'-------'---._......._.._—..-----'—'--------.. End Cac. I Black=.cc.tal!PC01,•,.)cop.iyrrer I r; g(t;i;o:}_...._. i r'.rtincaticrs ! • Cias A Fire Ratecl ingle .......................—- - ----- — ....._.._._.._._.._..------....-......_ _........------- --. ................. Compas;tion Sh Raft?r+ttachrn=r„ _... CL,r..pos-::on Shintgle Roof Decking,Aaachmer!, ` • • Aop;icatlon I _ r od anti Flat Ue :;:;!r rt:.rc'•!rricri, Un versal Interface for Cher R:3pf Attavtrienr-s. R,`:;r co roof a¢achment hardt ar'e rrnanufaccurer`s Ciocurrientauor,, .... ..................................... ......_........................................................ .......................................... .. ................................... ................. .._._........... .._......--- ......................._._ ..........._.....—..._.............. ---' —' 'Module innnt+liar's e.nrrihat:i:irr.ti•!:ir rhe:Ir'va0,9:,ur::sy.,te.-,•r:quurd tc;r h.ir:^,yore it':!r.�rory::rahr6ty. ! .. .,'-' . ,::c. �,::�.. a;,; ,�!.:n ovier:.t,rpora;ion. At'Ripi�csf;e;eryed. �ti;^dPCPr!.:n,the.�lJ;d?C4J_k'!cro,a::alU>„Ia,....:.l:,retr::rmtrksorrrr;isrerr-d trademarks of Sur?ov,er Crrporat!on. All other!raderriarks .c•tn-prr>etty of i.err reme.:.e es:-s. >r.!npo,•:... :Jm Spe!ficadors included:n this data'oheet are sub!e.d to chj, .withc a nrtice. Docurnen[#509506 RevC Da 1 Sh Enphase Microinverters e g on:ANA..:.6;Il;r.S Enphase 1 WHS The high-powered smart grid-ready Microinverter Enphase iQ7HS MicroinverterT"' with integrated MC4 connectors dramatically simplify the installation process while achieving the highest system efficiency. The IQ Series Microinverters extend the reliability standards set forth by previous generations,and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014,2017&2020) Efficient and Reliable Optimized for high powered 66-cell*modules Highest CEC efficiency of 97.0% More than a million hours of testing Class II double-insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support,voltage and frequency ride-through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) ' •The IQ7FiS is required to support 66 cell modules. E 1 V Y•�g� ®H i'�'1 qS E, To learn more about Enphase offerings,visit enphase.com l Enphase 9Q7HS Microinverter INPUT DATA(DC) IQ7HS-66-M-US .:.Coirirriodly;usad'iiiodule-pairin'gs "320 W='460 W+ Module compatibility 66-cell PV modules Maximum input DG;voitage 59 V Peak power tracking voltage 38 V-43 V Min/Max start voltage 30 V/59 V Max DC short circuit current;(rriod'ule:)sc) Overvoltage class DC port II Dil porf fiack•feed outrent'; 1�a-.�. PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) @240 VAC @208 VAC ;Peak`outputpower'`v" ,: - 384:VA' " '. ` 369 VA Maximum continuous output power 384 VA 369 VA *6iM►ar ,'vol l.,L ts eZran e. '; 24bv-/211-264�V... 201341183-229 V (` `} 9 92 Maximum continuous output current 1.60 A(240V) 1.77 A(2.08V) `NoEiiirial:frequency:" y:',;,.::.` 66Nz- 60,'Hz _. . , Extended frequency range 47 to 68 Hz 47 to 68 Hz AG'stiort;circuit;faut current'oVer'3;cycI 4,.,82,A �3 l .82 A t, Maximum units per 20 A(L-L)branch circuit3 10 9 Ovetvoltage class AG:pork }r+'sy.. _, �, Illi ,. III AC portMbackfeed current 18 mA 18 mA Power factor setiing ;dt.,'.i'r 't rx; . 10^<.. 1.0 Power factor(adjustable) 0.85 leading...0.85lagging 0.85leading...0.85 lagging EFFICIENCY @240 V @208 V CECWplgfited;efficiency 97.0% 96.5% MECHANICAL DATA Ai iblent.10m' perature range 400C to+60°C Relative humidity range 4°i to 100!u(condensing) Connectar'type Staubli made MC4 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight' 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved`for wet location's Yes Pollution degree PD3 Enclosure Class 11,corrosion,resistant polymeric enclosure Environmental category/UV exposure rating NEMA type 6/outdoor Altitude. 200t7rr1` ". „rj.-,,;..:;{.,n4r.: ,r. FEATURES Communication. ,Power,;Line-Communication(PLC) ;. : Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. Compliance CA Rule`21"(tJL 1741-8A),HECO v1.1 UL 62109-1,:60741AEEE1547,FCC Part 15 Class B, ICES'0003,.ClaswB s>-�' CAN/CSA-C22.2 N0:.107.1-01 tl:•,,t'`° �.,�i^ 'h;�: r •r'tar .. This product is'UL Listed as•PV Rapid Shut Down Equiprh6iit��nd)tc,'onfgrdi§wWiith NECa2014a NEC- 2017sect1onr690,12:.NEC 2020 and C22.1 2015 Rule 64 218iRapid;Siiutdotivn of'PU Systerris,for AC and bC`cond6ctors;when installed according to mari�facturer s instructioiis> ; 1.No enforced DC/AC ratio.Seethe compatibility calculator at httos7Nenphase com/en-us/sup port/module-compatibilily, 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com :r 2022 Enphase Energy.All rights reserved All trode.marks or brands used are the!:rop?rty e`:-nphase Fnergy,Inc ENPHA S E, 1 -18 2 22 �+ • a l —----------- ARKA SERIES ALRFX QD WSMDi-395 to WSMD-415 One with the Sun .............. .......... Highest reliability& Better performance. Split junction bDX' Reduced power PID resistant Sustain heavy M6 Mono enhanced crack under all losses up to with long wind&snow loads PERG cells tolerant 98B climatic conditions 1/4 times term reliability (2400 pa&5400 pa) module 1-V VARIATION WITH IRRADIANCE — a— a.. 1-V VARIATION WITH TEMPERATURE 59 1. 25 The Graphi are,for reference pur.pose qnly.Pease consult Waves tLcirlica:team for hirther 018F]facatiu'.N. 1DK 9800% INTERNATPONAL & 0 linear Paf.m....Warranty 91.95% Cl Standard Performance Warranty NATIONAL CERTIFICATIONS IEC61215 I 1EC61730 UL6'1730 IEC TS 62804-1 CE LISTED 5 12 27 IS09001:2015 I IS014001:2015 1 11304,5001:20118 Independ6nt assessment of factories by BLACK&WATCH ................ 0 ARKA SERIES IMAREE WSIVIDi-395 to WSIVIDi-415 one with the Sun ELECTRICAL CHARACTERISTICS ff ax,(Wl.:... !mp(A) Isc(A) Voc(� ;`,(IU(t dels Modullel 8ff 1YbP,' ;(YOGI STC,' fdOCT STG`" :NOCT: STC NOCTI _ •: > WSMD-395 395 296.8 37.77 34.70 10.47 8.55 11.24 9.08 45.00 42.10 19.78 WSMD-400 400 300.6 38.00 34.90 10.54 8.G2 11.32 9.14 45.22 42.30 20.03 WSMD-405 405 304.4 38.22 35.10 10.61 8.68 11.40 9.21 45.44 42,50 1 20.28 WSMD-410 410 308.2 1 38.44 35,30 1H8 8.74 11.48 9.27 45.66 42.70 20.53 WSMD-415 415 312.1 1 38.66 35.40 10.75 8.81 11.57 9.34 45.88 42.90 20.78 ,tand€rd Test Conditans i,STCI-1000 NO irrdeiame,Air fvtass 1.5 and 25'C cell temperature.N06pal Operating fill Te'nper ure IEI O-890 W02irradiance,Xr Mnss 1.5;Amh;en,tempera!,jra 20'C end Wind sped 1 r1A. Average pacer reucdon°f 4.5%at 20O Pi;m2 as c.r IEC o0904-1.EAeas ng Uncsrrainty=3%. l System Voltage 1500 1 Series Fuse Rating 22 A MECHANICAL CHARACTERISTICS Length x Width x Thickness(L x W x T) 1924 mm(U x 1038 mm(W)x 35 mm(Tl Weight 22 k s Solar Cells per Module(Units)/Arrangement 132 cells/(11x6 11 11x6) Solar Cell Type&Size Mono PERC,8,31x 166 mm Front Glass 3.2 mm Low Iran and Tempered glass with ARC coating Encapsulate PID Free&UV Resistant Junction Box(Protection degree/Material) IP68/Weatherproof PPO Cable&Connector(Protection degree/Type) IP68 rated/Staubli MC4 Connector Cable cross-section&Length 4 mm`&1200mm Frame Anodized Aluminium Alloy.Anodization thickness 15 micron Fire rating Type 2 DESIGN SPECIFICATIONS THERMAL CHARACTERISTICS :,ro Temperature coefficient of Current(Isc),a(0/b/1C1 0.055ewao - m I, " ja Temperature coefficient of Voltage(Vocl,8(%/°Cl -0.285 aN j� Temperature coefficient of Power(Pm),y(°/a/°Cl -0.365 7 NOCT(°Cl 43-*2 :t6 j Operating temperature range(°C) -40 to 85 e.g:' I ......._r Waaree Energies Ltd.is amongst the to Solar Energy Companies and has the 9•r 9•• P 91 P country's largest Solar PV Module manufacturing capacity of 5 GW.In addition,it ! # is committed to provide top notch EPC services,project development,rooftop I solutions,solar water pumps and also in an Independent Power Producer.Waa ee } has its presence in over 325 locations nationally and 68 countries globally. 'if you need specific product certificates,and if module installations are to devieta n•cm our yuidance snecifiedinournstallatinnmanual,pleasacnntcctyourluualwaaree sales and wchnicalrepresentatives. 12.ears Product Warranty • 27`fears Power Output Warranty -!.The elacuroldategvenhereisferr(raencepurposeonP�, ;,.' ;J i ''.•.PI-aasncmnfirmyqurarza¢regmrom�nt�-vvvittitii'araln�iipcusentatirmti,EvJmptacdngpmu@acdas„".�..................c .,..,,.,.. :,. "` �ReferinstagaGnnlrtanuel;pstrue�onsfiWaoreeNiarrantystatE�rieiitEorterinsfisun;fdons:''-' ,"" ,• �WzereaReservesilierigfitCddiangeth'espeei5catorstmLhmiC'ribraotiea.z':'' nWN e.Waa.. .,.,. in ^rn wry :.., .`-.�;WE[1EfiA[)/395-495]132)MP.n•IC/GMZ/U1127:07:2Q22.:, 1`.'•'.:' �: .