Loading...
HomeMy WebLinkAbout50734-Z TOWN OF SOUTHOLD � t BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE y±4 SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50734 Date: 5/23/2024 Permission is hereby granted to Graham, Jean 1221 Hillsboro Mile #29A Hillsboro Beach, FL 33062 To: install generator as applied for. At premises located at: 475 Lake Ave, Southold SCTM # 473889 Sec/Block/Lot# 80.-3-17 Pursuant to application dated 4/15/2024 and approved by the Building Inspector. To expire on 11/22/2025. Fees: ACCESSORY $125.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $100.00 Total: $325.00 Building Inspector �raa " TOWN OF SOUTHOLD—BUILDING DEPARTMENT " Town Hal Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971 0959 �u Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southOldtownnv goy " Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. � Building Inspector: Applications and forms must be filled out in their entirety. Incomplete aM` applications will not be accepted. Where the Applicant is not the owner,an µ;� Owners Authorization form(Page 2)shall be completed. Date:04/15/24 OWNER(S)OF PROPERTY: Name:Jean Graham SCTM# 1000-80-03-17 Project Address:475 Lake Ave, Southold NY 11971 Phone#:631-407-5296 Email:lifish475@optonline.net Mailing Address:475 Lake Ave, Southold NY 11971 CONTACT PERSON: Name:AMP Architecture Mailing Address:P.O Box 152 Mattituck NY 11952 Phone#:631-603-9092 Email:bepperson@amparchitect.com DESIGN PROFESSIONAL INFORMATION: Name:Anthony Portillo, AMP Architecture Mailing Address:P.O Box 152 Mattituck NY 11952 Phone#:631-603-092 Email:aportillo@amparchitect.com CONTRACTOR INFORMATION: Name:. Mailing Address: Phone#: Email:. DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Other Generator $2,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No I 1 PROPERTY INFORMATION Existing use of property:S-, r o � \, Q,0_0 Intended use of property: S ��-p�,�,• , Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes;Mo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is irresponsible for all drainage,and storm water issues as provided by Chapter 236 ofthe Town code. APPLICATION 15 HEREBY MADE to the Ruikling Department for the issuance of a 604ing(Permit pursuant to the®wilding Zane Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)`for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):/�WQ 4pQ NAuthorized Agent Downer Signature of Applicant: Date: 41 1 STATE OF NEW YORK) SS: COUNTY OF � ) being duly sworn, deposes and says that (s)he is the applicant (Name of in Ividual signing contract) above named, (S)he is the (Co ractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith,. Sworn before me this day of 20-a N oKwpu DARCEE AUEENANGER PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC,STATE OF NEW YORK Registration No. 01A00019644 (Where the applicant is not the owner) Qualified in Suffolk County Commission Expires January 9,2028 I, residing at do hereby authorize 't to apply on my behalf to the Town of Southold Building Department for approval as described herein. 04/15/2024 ` er's Signature Date Jean M. Graham Print Owner's Name 2 ENE' ATOR GENERAL NOTE -- SITE LAYOUT NOTES: I. TH15 15 AN ARCHITECT'5 51TE PLAN $ 15 • 5 MIN. SEPARATION BETWEEN PROPERTY LINE SUBJECT TO VERIFICATION BY A LICENSED AND GENERATOR SURVEYOR. THE INFORMATION G1 REPRESENTED ON THI5 517E PLAN 15 TO THEi1 SEPARATION BETWEEN DWELLING AND ARCHITECT'S BEST OF KNOWLEDGE- GENERATOR EXISTING I • 5' MIN. SEPARATION BETWEEN ALL DOORS, 2.SURVEY INFORMATION WA5 OBTAINED WOOD DECKS WINDOWS, AND VENTS TO GENERATOR FROM A SURVEY DATED OCTOBER 25, • 5' CLEARANCE REQUIRED IN FRONT AND ON 2022 AND PREPARED BY: THE SIDES OF THE GENERATOR FOR SERVICING SCOALICE LAND I7.3'—•-� I SOUTH BAY AVENUE SLIP,N.Y. 11751 TELEPHONEOU 54)R240--17 49 ( c+ is MIN. V.I.F. EXIST. MHWM Vm x 4' DEEP ,f� -r gAS N BULKHEAD lg: DRYWELL _Z ".. EXIBTIN ' GRAVEL ' q BUFFER FLAC75TONE 1 "' PATH ` a,• STORYTFRAME ° RELINING U L AS5 HOUSE; Im PROPOSED GR INTERIOR iy FL STONEll U MODIFICATIONS PATH j m I +-1 + c GRASS 100, SETBACK Q U) I FROM _ BULKHEAD/ 0 PROPERTY T V.I.F. EXIST.. ... � ,� ' PROP:- �.,.,_� ' M LINE ` V0 x 4' DEEP � (18" MIN.) ORYWELL PROP. GAS I.. GENERATOR _ I .� 100, SETBACK r FROM RETAINING 0.4' WALL Z w 0) _- Q a >: uJ ' REPLACE EXIST. Q > Q ? 10 TRENCH DRAIN ff MIN. CONNECT TO ry *` C3 LU I I EXIST. DRYWELL ) PROPOSED Is PROP. LAMP OE XNERAL AC LL N w 1 N GE W Z BURIED � CP O _ �i OAS o PROPANE " "` �� EXISTING GENERATOR TANK ASPHALT It Lh — 1 4- , DRIVEWAYa LU L_ ,...... 4 w � � 60.00 �' R PROF05ED PARTIAL 51 TE PLAN PROPOSED SITE PLAN N 4,00 O SCALE: I" = lo'-O" SCALE: 1" 50'-0', BEARINGS SHOWN HEREO SYMBOL LEGEND BASED ON FILE MAP NON12R15 El MONUMENT FND WIRE FENCE I,P. / I.B. FND © GAS METER LP. / I . SET ❑W WATER METER p35a SPOT ELEVATIONS pd GAS VALVE U TILITY POLE pQ WATER VALVE } GUY WIRE TEST HOLE ` UTILITY POLE W/LIGHT TREE LIGHT POLE © SHRUB T -� SIGN BOLLARD yYo FIRE HYDRANT WETLAND FLAG yA 1 HT -BASIN i0) MANHOLE D.C. DEPRESSED CURB 0 "A"-INLET FE, FENCE "B"-INLET MAS, MASONRY _> - ® YARD INLET PLAT. PLATFORM YARD INLET W-W- WINDOW WELL z A/C UNIT B/W BAY WINDOW o E❑ ELECTRIC METER C/E CELLAR ENTRANCE a B/H " PVC FENCE (PVC) 0/H OVERHANG .1+ O� �r STOCKADE FENCE (STK) R/O ROOF OVER r 14++ L� 00;1/ _ —X— CHAIN LINK FENCE (CLF)CANT. CANTILEVER S/ry 9o31 G PILES- x,sa ® CROSS CUT C-0-L, GENERALLY ON LINE •-y 1„HEAD Q STAKE O/L ON LINE - - - BAH. WALL R,O.W- RIGHT OF WAY - OX 25�-► CO I VAUL COI WALL,W. d a. WA.1. - Q' PVC ' v1 FEN I FM LOT 4 TAX LOT 17 ' T zh WALL FM LOT 3 W 17 3 WALL TAX LOT 18 [~ FM LOT 5 2. a �I I TAX LOT 16 STORY d s f0 Bs I PER 1d n� o O O. OF Lot 8'DAM -� B � . {� eri y� '-� PEAK-24,34 '3 16. EDB8 F I FFLey_ 1 : sIPLAT ' i WALL : - OX WMA'S' fieS D. . I �PVR ON MAS REi �'s tea. 'F/FEN I FFL . CO %PHALT N `pV3 DRIVEWAY FND 432.14 �€ �� �...• .3 s �. �00000rrII m PIPE 0 60 J sr NI4 t B.B.CURB xv I TE OF PAVEMENT �0 4 LAKE AVENUE LANE DRIVE (50' WIDE) GRAPHIC SCALE * ALL ELEVATIONS REFER TO NAVD88' DATUM LOT AREA 12,079.05 S.F. 30 0 15 30 0.28 AC. IN FEET ) ��9 2022 REVI -I SURVEY TR JDL 1 inch = 30 ft. ?11 r 9 20221 REVISED r�Y T L JD 1 11/01 0 2[REVISED SURVEY JC JDL REV , DATE IDESCRIP ION BY 1 CHK SURVEY OF PROPERTY OF NEWSCALICE 14- 475 LAKE DRIVE LOT 4 and surveying MAP OF RE—SUBDIVISION MAP OF BLOCK F mjslandsurvey.com P:984-240-7999 MAP OF REYDON SHORES FILE DATE: 10/07/1936 MAP NO. 1215 1 South Bay Avenue, Islip, NY 11751 SITUATE SAND DR.:MC CREW.:JT SCALE: 1" = 30' TAX MAP N0. SOUTHOLD, TOWN OF SOUTHOLD DATE SURVEYED:10/28/2022 JOB No.S22-358]5 1000-08000-0300-017000 SUFFOLK COUNTY, NEW YORK .i 3 m•N :. $ i 1C. tv�s 41i[ L afflL i T L- L .� t2.11. <.£? tg _: `L�S e �v€`k•—F'z d u`3.= ors 4 4 C+ a i'zg AKsC - r-- - 3- --:', xf.3'... .s.,t,u S-:Lv ..- .- ,.:i,Pgs 2G;.: r. _,.aa..T3I*r.end' & .+a€�.::s t z F.3�.+�ro4' _# 9.€aE. ai EA x - r��- vra �=Fe ,r.�s_ T c �� t �- ,..K.s� ,�� a �m -.,c.i n-€�.t � �,:a -�w �. - �s e �:.�z -v. �. s:� � g _ 'a-�E�.u+.`.€-`�,a', aS�s�ia'-S:<c.S1'sYi.'i„s*L3 3#d°£'kk:,ft�+..4+b''t'�Z'¥-°_-� t �=�=C 6�-�e�'�"-�"�€la§i�C..�-e .sz Fes:;.i� €�"v�:_'•:.(�::-�<t:aa'€�?a`cvo�i4 H u£-3 t[.`sttz rC.,tom`t=oaf-=-_.£ss.�-3{ -.• ,'T.. _.€€*s.dF+c:','2 R'�s S�. r-.a.F.'C�5s�,..saf+.s..c� .-..._ - s--c< -. '. 4,22 =-IL f3s$ =6 L1i i :S- *- S-:-='J^✓?�t�`=11 .6. AFCSk#, > � , -����������� � .� GENERAC® APR 1 2 2024 GUARDIANO SERIES 20/22 W R-!�!,TUD_MTG-DEEFIZ Residential Standby Generators TOWN, !.7T Air-Cooled Gas Engine INCLUDES: Standby Power Rating G007033-1,G007039-1,G007038-3,0007039-3(Aluminum-Bisque)-20 6V 6011­1Z 0 True Power- Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kVV 60 Hz 0 Two-line multilingual digital LCD Evolution controller (English/Spanish/French/Portuguese) 0 200 amp service rated smart switch transfer switch available 0 Electronic governor 0 Standard Wi-FiO connectivity 0 System status&maintenance interval LED indicators 0 Sound attenuated enclosure * Flexible fuel line connector 0 Natural gas or LP gas operationGENERAC' 0 5 Year limited warranty 0 Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.* *Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. hffps.-Ilassets.swri.orgllibraryIDirectoryOfListedProductsI or C&us (QUIEFTE5T- Constructionindustry1973 DoC-204-13204-01-01—RevRpat 10% us LISTED Note:CETL or CUL certification only applies to unbundled units and unit ackaged with limited circuit switches.Units packaged with the Smart Switch areT or UL certified in the USA only. FEATURES • INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- 0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's SUCOSS in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all GeneraG mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at t1%. • TRUE POWER" ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave 0 SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. • TEST CRITERIA: 0 GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with • PROTOTYPE TESTED V NEMA MG11-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC • SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. • MOBILE LINKO CONNECTIVITY:FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. Lu�GENERAC Q@ @ .k PROMISE GENERAC" 20/22 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution'" Controls • AUTO/MANUAL DOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD display Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC' 20/22 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC� 20/22 kW Specifications Generator Model G007038-1,G007039-1 G007D42-2,G007043-2 G007038-3,G007039-3 G007042-3,GOOT043-3 (20 kW) (22 kW) (20 I(W) (22 I(W) i Rated maximum continuous power capacity(LPj_�-~ � �20,000 Watts'_ 22,000 Watts -2Q000 Watts' _ 22,000 Watts` Rated maximum continuous power capacity(NG) 18,000 Watts' 19,500 Watts' 18,000 Watts* 19,500 Watts' ,Rated voltage 240 Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 r [Total Harmonic Disloa6-nn -� -� -� Less than Main line circuit breaker 90 amp 100 amp 90 amp 100 amp ,Phase _A 1 --J Number of rotor poles 2 iRated AC frequency "� 60 hli ��N Power factor _ 1.0 BaVery rrequirement(not included) 12 VoOs,Group 26R 540 CCA minimum or Group 35AGM 660 CCA minimum ^--1 Unit weight(lb/kg) 448/203 466/211 436/198 445/202 fDimensions(Lx'WxH)in/cm � 48x25729/121.9x63.5x73.7 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load** 67 67 67 67 Sound output in dB(A)at 23 R(7 m)with generator in Quiet-Test'low-speed exercise mode" 55 57 55 57 _ Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series rNuumbef of cylinders 2 Displacement 999 cc Cylinder block Numinum w/cast iron sleeve ---� Valve arrangement Overhead valve Ignition system _ Solid-statew//magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC �,Oil_gapacity including litter �_. Apprm 1.9 qt/1.8L Operating rpm 3,600 Fuel consumption Natural gas ft3/hr(m3/hr) .1/2 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) Full Load 301(8.52) 327(9.26) 287(8.13) 306(8.66) Liquid propane ft3/hr(gal/hr)[Uhr] 1/2 Load 87(2.37)[8.99] 92(2.53)[9.57] 86(2,36)[8.95] 92(2.53)[9.57] Full Load 130(3.56)[13.48] 142(3.90)[14.77]. 136(3.74)[14.15] 142(3.90)[14.77] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas. For BTU content,multiply 113/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode bf— uttons:AUTO Automatic start on utility failure.Weekly,Bi-weekly�or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. _ OFF Stops unit.Power removed.Control and charger still operate. Ready to Run/Maintenance messages _ Standard `Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) i'Wtility Voltage Loss(Neturn to Utility adjustable(brownout setting) _ From l46-171 V%190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard R n AIarm/Malnlenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out r Starter cannot re-engage until 5 sec after engine has stopped.' Smart Battery Charger Standard Charger Fault/Missing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard _ Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection '— Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(:72 Hu)/rpm Sense Loss Shutdown Standard High Engine Temperature ShutdownStandard Internal FaulUlncorrect Wiring protection _ Standard Common external fault capability Standard Field upgradable firmware Standard '*Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1.000 ft(304.8 m)above sea level:and also will decrease approximately 1%for each 10'F(6'C)above 60'F(16'C). GENERAC� 20/22 kW Switch Options Service Rated Smart Switch Features G007039-1(20 kW) _ • Includes digital power management technology(DPM)standard. Model 0007043-2(22 kw) G007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. 0007043-3(22 kW) • Up to eight additional large(240 VAC)loads can be managed when used in yNo.of°-- pales_ r 2 conjunction with Smart Management Modules(SMMs). Current rating(amps) 200 • Electrically operated,mechanically-held contacts for fast,clean connections. I Voltage rating(VAC) 120/240.10 • Rated for all classes of load,100%equipment rated,both inductive and resistive. Utility voltage monitor(fixed)` o r -Pick-up 80% • 2-pole,250 VAC contactors. -Dropout 65% • Service equipment rated,dual coil design. Return to Utility* Approx:l3 sec Exercises bi-weekly for 5 minutes* Standard • Rated for both aluminum and copper conductors. ETL or UL listed Standard • Main contacts are silver plated or silver alloy to resist welding and sticking. Enclosure type NEMA/UL 313 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting Circuit breaker protected 22,000 flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly or monthly wr . 200 Amps 120/240,to Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 fp H1 cm 67.95 76.45 26.67 34.29 17.55 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400 MCM-#4 350 MCM-#6 2/0-#14 I-DEPTH� L_W2 GENERAC" 20/22 kW Available Accessories Model# Product y Description I G005819-0 126R Wet Cell Battery j Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery 1 for use with all air-cooled standby product(excluding PowerPact°). G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not necessary for use with AGM-style batteries). r I G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). i G007103-1 I Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates i where heavy icing occurs. G005621-o I Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not Contact Kit be needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,con- (Standard on 22 kW) toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corro- sion.The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring Monitor the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected powerfailure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large G007006-0(100 electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can amp) reduce the overall size and cost of the system. G007169-0 Mobile Link°Cellular The Mobile Link family of Cellular Accessories allows users to monitor generator status from anywhere in the world, Accessories using a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. L Dimensions & PCs Model UPC 637.6 mm 1218 mm [25.1 In] 146.0 In] G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727.2 mm G007042-3 696471074208 [28.6 in]' G007043-2 696471074215 G007043-3 696471074215 o 0 0 646 mn] 1232 mm [25.51n] [48.5 InI LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENERAC" Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000221268 Rev.B 05/28/2020 GENERAC" 20/22 kW Available Accessories Foel# Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell I battery for use with all air-cooled standby product(excluding PowerPact°). G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not necessary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103 1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates ' where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not Contact Kit be needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,con- (Standard on 22 kW) toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque^Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corro- sion.The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring Monitor the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected powerfailure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.it manages large G007006-0(100 ; electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can amp) i reduce the overall size and cost of the system. G007169-0 Mobile LinkO Cellular The Mobile Link family of Cellular Accessories allows users to monitor generator status from anywhere in the world, Accessories using a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proactive service.With I{ Mobile Link,users are taken care of before the next power outage. Dimensions & UPCs Model UPC 637.E mm 1218 mm r25.1 int 148.0 In[ G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727.2 mm G007042-3 696471074208 128.61"� G007043-2 696471074215 G007043-3 696471074215 o i o 0 648 mm 1232 mm [25.5 in] [48.5 Ini LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RAC' Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com ©2020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000221268 Rev.B 05/28/2020