Loading...
HomeMy WebLinkAbout50747-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT `P TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50747 Date: 5/28/2024 Permission is hereby granted to: Bellezza, Dominick .. ..... .........................__. __ _....................-.—.......... 20 Seawood Dr ... ....._... ............... ..... ................................ Southold, NY 11971 To: Install roof mounted solar panels to an existing detached accessory garage as applied for per manufacturers specifications. Additional certification may be required. At premises located at: 20 Seawood Dry Southold SCTM # 473889 Sec/Block/Lot# 88.-2-10 Pursuant to application dated 4/17/2024 and approved by the Building Inspector, To expire on 11/27/2025. Fees: SOLAR PANELS $100.00 CERTIFICATE OF OCCUPANCY $100.00 ELECTRIC $125.00 ..................................................... . Total: .. $325.00 Building Inspector 'I'OWN 10F SOU THOLD -BZrILDING DEPARTMENT ENT Tcvgn Hail Annex 54375 Main road P. ®. Box 1179 Southold, NY 1 1 97 1-0959 Telephone (631) 765-1802 Fax (631) 765-9502 �.------------------ _ -...... a Date Received � y l rAPPA ICATION FOR BUILDING PERMITi For Office Use Only j G a �0`1L+�1 �PERMIT�10. euildinglnspector.��u.._� ..-� I Applications and forms must be filled out in their entirety.Incomplete applica cns Y01 not be accepted. Where the Applicant Is not the owner,an Owners Authorizationform(Page 2)snail be completed. C C Date: /V C� I OWr4EiR(S)OF PROPERTY- ae: m1n1a�- ��(� 2—Z ShrTi�/i# 1000 C��g U U - �oZOuress: Phone#: s Email: Mailing Address: u-46 ) CONTACT PE Name: 9 f Mailing Address: -7 4 C) S o Lo d, Phone#: (P3 � d 3 9 9 �7 0 LJ Email; DESIGN PRViFESSMNAL INFORMATION: Y Name,. Mailing Address: � � Phone#: Email: Name: Mailing Address: Phone#: �� I o � � °'� � � � Email: DESCRIPMON OF PROPOSED C® r>-MU'C 1 ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: therm' 5+- -d la-r P V 3_'9 2 KW $ Will the lot be re-graded? ❑Yes No Will excess fill be removed from premises? ❑Yes o CA M u d�e��- C� C 7'-&7,.- 13 dc- �-( - C� 2 t-`f zS`'o s I PROPERTY INFORMATION Existing use of property: Kk--A— Intended use of propert . Zone or use district in which premises is situated: Are there any coven nts and restrictions with respect to \►,P�"�`,', this property? A lyes a IF YES, PROVIDE A COPY. heck I3ox After" 1:1sadi ngo The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Lorraine �iPent a AISplicati®n Submitted BY(print name): Lrr Aalth®rozec/i Agent ❑Owner Signature of Applicant- �( �—c�{— Date: 3/.?- l�'y STATE OF NEW YORK) SS: COUNTY OF Suffolk Lorraine DiPenta being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file thereV )S J ROM,EO Notary Public,State of New York Sworn before me this No.01R06314813 QuaCommission fied lCounty p November 1 ,20 day of r " �� �`��' \ ,20� Notary Public PROPERTY OWNER Au r�mRIZATION (Where the applicant is not the owner) I residing at C2 0 E-bJ&J006k--, (jVl VC_; , " do hereby authorize Cttn eyyt- nA-M cc -i> 14AiNto,apply on n rr�behalf tag the aw of So th id Building Department for approval as descri ed he ein. X ( 3 wner's Signatur LOUIS J ROMEO bate Notary Public,State of New York No.01 R06314813 Qualified in Suffolk County Print Owner's Name Commission Expires November 17,2©Zsp 2 F drw %oFF0M BUILDING DEPARTMENT- Electrical InspectorTOWN OF SOUTHOLD � � ISO` Town Mall Annex - 543751 Main Road�.�,PG Sox 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 .. ro err�southoldtown! o seand�sout'holdtow nn ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: F I " , 11(=f Electrician's Name. No. � License � w �,� �� �1 � Elec. email. Elec. Phone No: Z,.),,J - )7e' 01 request an email copy of Certificate oaf Compliance Elec. Address.:] _ a �yY1 ' "t I e JOB SITE INFORMATION (All Information Required) G Name: -Do Address: (:� 6 ,�O_to (D 0 6�, ­�:) " S Cross Street: m 6LA-(l 6 i t V,� RA, Phone No.: ?) l- -11 9 -1 c.R T " 3 - 3 �g - SIdg.Permit #: 15C)t1l email- . Tax Map District:. 1000 Section: 02%r . oo Block: b 00 Lot: 0I 0• 0' BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): ......Square Footage:... Circle All That Apply: ' Is job ready for inspection?: YES N® Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information- (All information required) Service Size 1 Ph 3 Ph Size: A # Meters ®Id Meter# ❑New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground ElOverhead # Underground Laterals 1 FJ2 H Frame Pole Work done on Service? Y N AIditionai Information: i � t 4 �� � PAYMENT DIEWITH APPLICATION Workers'sTAI Compensation CERTIFICATE OF INSURANCE COVERAGE . Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1 To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carried 1a.Legal Name 8 Address of Insured(use street address only) 1 b.Business Telephone Number of Insured _,,.... . ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK,NY 11952 i 1 c.Federal Employer Identification Number of Insured f"Work iocatier of Insured(OnlyregrWred ifcauerage is specrflCallylirrlrted to or Sodai Security Number certain locations in New York State,r_e.,Wrap-Up Policy) 823336604 2.Name a... Entity equesiinWWWWProoiof Cove ...... _ and Address of En' R me of Insurance Carrier (Entity Being Listed as the Certificate}bolder) i TOWN OF SOUTHOLD ShelterPoint Life Insurance Company i 54375 MAIN ROAD 3n.Policy Number of Entity Listed in Box"Ia" SOUTHOLD,NY 11971 DBL567527 i 3c.Policy effective period C 0110112023 to 12131/2024 A r Both disability following oenefts: 4. Policy i ® paid family leave benefits. B.Disability benefits only, C_Paid family leave beneftis only_ V 5. Policy covers: ® A.Al of the employers employees eligible under the NYS Disability and Paid Famdv Leave Benefits Law. B.Only the fallowing class or classes of employer's employees_ urnsured has penalty NYS Disability andfo Paid Family L e Benefits insurance coverage as describedabove.s n srser referenced above and lfaa�t ltre named 7/10/2023 ° Date Signed By ('164a (Signature of insura;, carrier's authorized representative cr NYS Lkensed insurance Agent of that insurance carrier) Telephone Number 516-829-8,100 _ Name and Title Richard White Chief Execulrve Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit, PO Box 5200,Binghamton,NY 13902-5200. PART 2 To be completed b the NYS Workers'Coin .. �_.. .... �. P Y Compensation Board(Only H Box 4B,4C or 58 have been checked State of New York Workers' COm eneatlon Board According to information maintained by the NYS Workers"Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Articfe 9 of the Workers'Compensation Law)with respect to all of their employees„ Date Signed By (Signature of Authorized NYS Workers'Compersation Board Errpiovee' Telephone Number Name and Title agenss ofY as�rnsurance c rne�s car is eJ crazed a slue Fcris D8 ty and paid family leave benefits insurance policies and NYS licensed insurance Y _, 20 I Insurance brokers are NOT authorized to issue this ...r. ...�„ D -1211 (1 - 1) 1 gg I ' `% CERTIFICATE OF LIABILITY INSURANCE °A'E'MN711� THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BEL01N_ THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: tI the certificate holder is an ADDITIONAL INSURED,tale pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorSement(s)„ PRODUCERCONTACT ROBERT S. FEDE INSURANCE AGENCY F"E _23GREEN STREET,SUITE 102 . —...fal HUNTINGTON,NY 11743 ._ .. _ ......ROBERTS.FEQE INSURANCE fWs1JRE Sti AFFge1 c0 TLAN'TI�C CASUALTY INS.CO 524210 INSURED - Element Energy LLC IN$N)is` INSURERC: DBA ELEMENT ENERGY SYSTEMS - - 7470 SOUND AVENUE D' MATTITUCK, NY 11952 E �P: d COVERAGES CERTIFICATE NUIYIBEiZ_ REVISION NUMBER: THJS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INS TR . TYPE OF INSURANCE N"Sn vivo7:L14500:10MJ1 IdIiA�I LIM[T9 oucY Nu CC4AMERCIAL GENERAL LIABILITY 73 EACH r�CC MEN+ICE 1 3 000,000 A X7/14/2023 7/14 2024 PeNI ECLtiwNS MADE OCCURMEDEXP9 I 5000 � � �X I Contractual Lia B 7/19/2022 i 7I19120Z4 .PSASOLaAOVINjURY3 3�3�'013t O .7 1I GEPL AGGREGATE LIMIT APPLES PER ,GEr€RAL AGTEx"t-, � i POLC JPERCOT- F]LOC PRODUCTS w C G .----. .......... OTHt �€'I A1ITOMOMILE Li0.BY.JTY ANY AUTO I BODILY NVJURY(Per person) f OWNED SCHEDULED AUTOS ONLY AUTGS BODILY IWURY� (Per mat) f HIRED NON-OWNED ^-- -----�— & AUTOS ONLY -.AUTOS ONLY ERre AGE 3 ! UMBRELLA LIMB CC-CUR #I EACH r,IcouRRer t � E�SS LUIB CLAIMS-MADEAGCIiEGgTE RETEB+rTICFIII i WORKWIS TrrT 124494445 PER o AN s u D EMPLorenAearTv y N$1 7A X023 7/1312024 ER ANYTN UTIvE' EL FACI+ACCWENT S 113 ��NINE7NCLUDEg7 NlA ..._.. ..d Wdosabe EL DISEASE-EA EMPLOW 3 dFdPMCN OF OPERArONS NOW EL DISEASE.POI ICY N.I WT ! NY State DBL DBL5137527 1/01/2023 12/31/2024 Statutory DESCRIPTION OF OPERATIONS!LOC'ATKM I VENCLES fACORD 101,AddMonal Remarks Sd I9dWe,maV rye atJA~Ir fflM space is re*dmd) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main RDa4d THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold, NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE R �erF S. Fed e., 1988-2015 ACORD CORPORAT;ON. All rights reserved. arnurs �s.�ne�:n1 7%, A4'n0M �.- .,__ r r r.e. . ,..._.U_,.r A r^Mn 4� NYSIF New York Stats Insurance Fund PO Box 66699.Albany,IVY 122C8 I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) A^"A A A 823336004 ' ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE r YHOLDER CERTIFICATE HOLDER ENT ENERGY LLC TOWN OF SOUTHOLD ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD SOUNDAVENUE SOUTHOLD NY 11971 TTUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 369075 07/1312023 TO 07113/2024 7111/2C23 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO_ 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WIIH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR VVEBSITE AT WTTPS:IIWWW.NYSIF.COMICERT10ERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, (PRIOR TO THE DATE OF THE ACCIDENT. THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REOUIRES THAT SUCH RIGHT OF SUB-ROGAT*N BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT 16OE FUND CIRF " ��L1P4',51�RAdNCE 6`(.,6NIC UNOElR'�J' :IIIM4G Zoho Sign Document ID:2A768FFA-TGGXYIZJQNOHG4KDBWOONJSAP-3Q7ZYZ6HPJL2A7MFY a'7 9 - use sS�S SCOPE OF WORK DESIGN a DRAFTING BY: nhForkTable&inn :� ELEMENT ENERGY LLC TO INSTALL A 3.825 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT BELLEZZA RESIDENCE, r, REVIEW BY J.M.NABCEP CERTIFIE LOCATED AT 20 5EAWOOD DR,SOUTHOLD, NY 1 1971. @ ,,;�, d = 051 1 12-129 Sparkling Pointe n 111 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH "7 • . THE EXISTING ELECTRICAL SERVICE EQUIPMENT. ers drag Pane - .-d SAu B REVISIONS Tarp- DESCRIPTION DATE REV SYSTEMRATING s ;• ORIGINAL 04_12_2024 P x WalkYneyards - .. . 3.825 kW DC 5TC Shell EQUIPMENT SUMMARY 9 QCELL Q.TRON ELK M-G2+425 WATT PV MODULES - ell COlans 9 ENPHASE IQ8PLU5-72-2-U5 MICRO INVERTERS CONTRACTOR I IRONRIDGE XRI 00 MOUNTING SYSTEM ELEMENT ENERGY, LLC. SHEET INDEX .;1 7470 SOUND AVE PV-I COVER MATTITUCK, NY 1 195 PV-2 SITE PLAN PROJECT LOCATION LICENSE# G74G I-HI PV-3 ROOF PV LAYOUT LICENSE# 52689-ME PV-4 STRUCTURAL/DETAILS SECTIONS , PV-5 3-LINE ELECTRICAL DIAGRAM PV-G LABELS OF NE(v GOVERNING CODES '► ��P��o A 2017 NATIONAL ELECTRICAL CODE. 2020 RESIDENTIAL CODE OF NEW YORK STATE. n °cr= U 2020 FIRE CODE OF NEW YORK STATE. to 1 2 A5CE 7-1 G AND NFPA-70. Zcf� �� _ '' 0 UNDERWRITERS LABORATORIES(UL)STANDARDS BOA �03443 , _ OSHA 29 CFR 1 91 0.2(;9 m Rp NPR' GENERAL NOTES J y �ssto PROJECT NAME 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE LL- 0 AGREELT EISAMEE INTENT OF THESE PLANS AND MAKE WORK AERIAL VIEW w U > m 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED ) w DZ . APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. TOWN COMMENTS AND APPROVAL STAMP `� N o } INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM uJ z AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, g � DO o COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO N Q O ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. o LU n I=- JURISDICTION. 1 1. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR u w O 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS 0 m N O WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE � n THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS O ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND 0- CONTINUE WITH THE WORK, HE SHALL ASSUME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT RESPONSIBILITY AND LIABILITY THEREFROM LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY SHEET NAME FABRICATED AND INSTALLED AS PER LATEST A.I.S.0 SCAFFOLDING STAIRS, ETC.. AS WELL AS PERMANENT COVE SPECIFICATIONS. CONSTRUCTION. G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE 12, FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING NYS CODES$ REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. DRAWING SCALE CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY TH15 8. THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON n .I.C . SHALL REMAIN THE PROPERTY OF N THE ENGINEER WHETHER THE A WEEKLY BA515 OR SOONER IF CONDITIONS WARRANT. 5J PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE EXTENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF SKEET NUMBER EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV- RESULT OF HIS WORK. TAX MAP: 1000088000200010000 Zoho Sign Document ID:2A768FFA-TGGXYIZJQNOHG4KDBWOONJSAP-3Q7ZYZ6HPJL2A7MFY LEGEND TAX MAP: 0400-1 G5.00-02.00-OG5.000 DESIGN$DRAFTING BY: EXISTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL NEW PV SUB-PANELS REVIEW BY J.M.NABCEP CEP.TIFIE A/C DISCONNECT N 051112-129 � COMBINER INVERTERS -GND ELECTRODE Co REVISIONS ME 1 PV MODULE DE5CRIPTION DATE REV —RACKING RAIL 7- goo ORIGINAL 04-12-2024 o ATTACHMENT POINT CACHED GARAGE W voo4 ---RAFTERS j;o � 120` -ROOF PITCH ANGLE 240 0 �SUNRUN METER 210o 180150 NET s OPLUMBING VENT -- 00 ®SKY LIGHT ®CHIMNEY CONTRACTOR ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. GOOD CONDITION �TPOTENTIAL SHADING ISSUES MATT 0 SOUND, NY II AVE RIM/REMOVE AS NECESSARY 52 LICENSE#G74G I-HI LICENSE# 52G89-ME of NE4, o A G'Gs0 �p, oLU +T' 1 �O 1034A3 ARQFESSIONP� PROJECT NAME O IL w U j P w o U) p w O z Q o N w ° o J j o m o 0 0 SHEET NAME 51TE PLAN 'NOTE 1.)THE ROOF SETBACK/PATFIWAYSNALL NOT BE DRAWING SCALE REQUIRED ON DETACHED NON-RESIDENTIAL STRUCTURES IN ACCORDANCE WITH R324.G OF— I/Q11 = I 1-011 2020 NYS RESIDENTIAL CODE. Cl CONSTRUCTION NOTES 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NUMBER MANUFACTURERS INSTALLATION INSTRUCTIONS. �` ,_ 2.)ALL OUTDOOR EQUIPMENT SHALLv BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000085000200010000 Zoho Sign Document ID:2A768FFA-TGGXYIZJQNOHG4KDBWOONJSAP-3Q7ZYZ6HPJL2A7MFY CONSTRUCTION SUMMARY LEGEND DESIGN b DRAFTING BY: (9)QCELL Q.TRON BLK M-G2+ 425 WATT PV MODULES EXISTING UTILITY METER ELEMENT ENERGY LLC MAIN SERVICE PANEL REVIEW BY J.M.NABCEP CERTIFIE(DIMENSIONS: G7.8"X 44.G"X I.4") NEW PV SUB—PANELS OSI 1 12-I29 (9) ENPHA5E IQ8PLUS-72-2-U5 MICRO INVERTERS A/C DISCONNECT (18)ATTACHMENT POINTS @ G4"O.C. MAX. COMBINER (G7.7) LF IRONRIDGE XKI 00 MOUNTING SYSTEM. INVERTERS ROOF TYPE: ASPHALT SHINGLE(SINGLE LAYER) (D GND ELECTRODE REVISIONS DESCRIPTION DATE REV PV MODULE ORIGINAL 04-12-2024 CONSTRUCTION NOTES —RACKING RAIL 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 0 ATTACHMENT POINT WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ---RAFTERS 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH PROOF PITCH ANGLE MINIMUM NEMA 3R RATING. �SUNRUN METER 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE ®�T FIELD VERIFICATION. OPLUMBING VENT ®SKY LIGHT CONTRACTOR ®CHIMNEY ®COMPOSITE SHINGLES ELEMENT ENERGY, LLC. GOOD CONDITION 7470 SOUND AVE POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSAR MATTITUCK, NY 1 1952 LICENSE# G74G I-HI LICENSE# 52G89-ME of: NER, A GAG 0,A ETACHED GARAGE s Yai 0 W �O 1034A3 PROJECT NAME 0 w W r w U > z O o z o O g Dz Q o 0 o N w 0 0 o m ° SHEET NAME N PV LAYOUT o° DRAWING SCALE W 270°� 120° I/811 = I I—OII 240° 150° 'NOTE 210°180° 1.)THE ROOF SETBACK/PATHWAY SHALL NOT BE S SHEET NUMBER REQUIRED ON DETACHED NON-RESIDENTIAL PV-3 STRUCTURES IN ACCORDANCE WITH R324.G OF 2020 NY5 RESIDENTIAL CODE. TAX MAP: 1000088000200010000 Zoho Sign Document ID:2A768FFA-TGGXYIZJQNOHG4KDBWOONJSAP-3Q7ZYZ6HPJL2A7MFY ITEM DESCRIPTION ARRAY#I DESIGN 4 DRAFTING BY: LOAD CALCULATION ARRAY#1 RB Ricicle Beam/Board 2"X 10" D. FIR ELEMENT ENERGY LLC R Rafter 2"X 8" D. FIR I Gil O.C. REVIEW BY J.M.NABCEP CEP.TIFIE MODULE WEIGHT(Lbs) 4G.7 (C) Collar TIe5 2"X 4" D. FIR @ 48"O.C. 051 1 12-129 #OF MODULES 9 (P) Pitch 43° (D) Deck ng 5/8"PLYWOOD REVISIONS TOTAL MODULE WEIGHT(Lbs) 420.3 Q) Ceilln Joist 2"X 1 0" D. FIR I G"O.C. DE5CRIPT10N DATE REV TOTAL LENGTH OF RAIL(Ft) G7.7 H) tlorizontal S an of(R) 14G"MAX. ORGINAL oa-Iz-zoza RAIL WEIGHT PER FOOT(Lbs) O.G8 (PQ (Rg) TOTAL RAIL WEIGHT(Lbs) 4G.0 #OF 5TRANDOF1`5 18 (D) WEIGHT PER 5TRANDOFF(1-195) 2 TOTAL STANDOFF WEIGHT(Lbs) 3G TOTAL ARRAY WEIGHT 05) 502.3 POINT LOAD(Lb5) 27.3 CONTRACTOR TOTAL ARRAY AREA(Sq Ft) 192.7 _ ELEMENT ENERGY, LLC. ARRAY DEAD LOAD(Lbs/Sq Ft) 2.G 7470 SOUND AVE(P MATTITUCK, NY I 1352 WIND DESIGN SUBJECT TO DAMAGE FROM (C) LICENSE#G74G I-HI GROUND SEISMIC WINTER ICE BARRIER AIR MEAN LICENSE# 52G89-ME FLOOD LOAD' Speed" Topographic Special Windborne CATEGORY'GN Frost DTEMPN UNREQUI DENT HAZARD5J FREEZING ANNUAL (mph) effectsk wind region debris zone'" Weathering line t Termite` depth �of NEj�Y 20 140 NO NO NO B SEVERE 3 FT hOEPD 15°F YE5 ZONE X 599 5 1°F C-3 MANUAL J DE51GN CRITERIA" Indoor (0f1 11J Winter Summer design Heating temperature (J) 2 Elevation latitude heath cooling Altitude correction factor Design temperature cooling N s 9 9 tempera difference r034A3 ture p R�FES ' 108 FT 41°N 15°F 50 F 1.00 70°F 75°F 55°F S1oNP� I�� I Wind Wind ROOF FRAMING DETAIL I I Cooling temperature d PROJECT NAME difference velocity velocity Coincident Daily range Winter Summer humidity _ heating cooling wet bulb humidity O 5°F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GP @50%PH _ W W For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. L U > 0) Z IZ/ a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth t — strength required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as MODULE MOUNTING CLAMP 0) [n determined from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. 1Z � O Z b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction SOLAR MODULE DZ C shall fill in the frost line depth column with the minimum depth of footing below finish grade. N C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. STAINLESS 5EEL 3/5" p w w Z: d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined BOLT AND NUT u.J L on a site-specific basis in accordance with Section R301.2.1.4. U) w O e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York 0 In N State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also O see Figure R301.2(1).] NRIDGE ALUMINUM RAIL f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New ALUMINUM V'BRACKET York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: ALUMINUM FLASHING SHEET NAME i.The accompanying Flood Insurance Rate Map(FIRM), ' ii.Flood Boundary and Floodway Map(FBFM),and p p iii.Related supporting data along with any revisions thereto. STI\U CTU I\AL The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ASPHALT SHINGLE ROOF effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." 5/1 G"x G"5TAINLE55 I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure-R403.3(2)or from the 100-year(99 percent) STEEL LAG BOLT WITH value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)" 2 1/2"MIN THREAD j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method PENETRATION SEALED DRAWING SCALE (Base 32°F)." WITH GEOCEL 4500 k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the (EQUIVALENT OR BETTER) AS NOTED jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. 1. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. SHEET NUMBER in. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1 b from ACCA Manual J or established criteria determined by the I I jurisdiction. I o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at MOUNTING DETAIL I V-4 elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. TAX MAP: 10000560002000 10000 r) See Figure R301.2(4)B. s Zoho Sign Document ID:2A768FFA-TGGXYIZJQNOHG4KDBWOONJSAP-3Q7ZYZ6HPJL2A7MFY PPOP05ED 501AP ARRAY ON THE GARAGE 3.825 kW DESIGN b DRAFTING BY: (9)QCELL Q.PEAK DUO ELK ML-G I O+400 WATT PV MODULE5 (I)STRING OF(9)MICRO-INVERTER5 ELEMENT ENERGY LLC '(1)STRING TOTAL REVIEW BY J.M.NABCEP CERTIFIE 051112-129 STRING#3 -------- -- - • • REVISIONS DESCRIPTION DATE REV ORIGINAL 04-12-2024 ENPIIA5E BRANCH PROPOSED NEW PV SYSTEM CIRCUIT CABLE TYPICAL 1,11CR0414VERTER ERPHA5E 108PW5-72-2-U5 240 VAC.1.21 A 97T.CEC-WEIGHTED EFF. HEMA G.UL 1-15TED TYPICAL I I I / FX15TING 50LAR ARRAY ON MAIN HOUSE 9.2 kW to TO UTILITY GRID (23)QCELL Q.PEAK DUO ELK ML-G 1 O+400 W PV MODULES (1)5TRING5 OF(13)MICRO-INVERTER5 L(1)STRING OF(10)MICRO-INVERTERS '(2)STRINGS TOTAL ON MAIN HOUSE oLAR MODULE TYPICAL 1 �R nee zm zlr,)m as9csarr" IL E11111A5E I11COMBINER4 AC 015CONNECT Ex.:EEJ 10 FT N STRING#I I iiln3ovaeaeegec:z 2-Dg22e^A O unuTY METER L CONTRACTOR ________ _ - - IE- RFC 1` I-PHA5E.240V ELEMENT ENERGY, LLC. ___ • • • - E PNAS [ 1 1 7470 SOUND AVE 1 N -- -- TYPICAL R i �a e,A S2A4.^yc�RCev"e,;i1JV + __ xµ(5;:1"`9.Ea(A MATTITUCK, NY 1 1952 I ■ ■ -D �R LICENSE# G74G I-HI LICENSE# 52G89-ME STRING#2 G I1 1 r------- ° --- ° I ,( r- N 1 94Po CEC-WEIGHTED EFF. - - I 1 1 1 1 NA V-_^4A`M1 O ENPHASF I(7]PW5-2-2- US J __________________ 240 VAC.1.21 A �� G1 EIlPHASE BRAIJCM _-- -_-- -_-- NEM4 6,UL USTED � ^ CIRCUIT CABLE TYPICAL TYPICAL I 1 > L A r" CJ C• W I I �= I EXISTING AC DISCONNECT _ SUB PANEL N � ' m I I z^v=?eon I G l ,I I n_NA R.IL L'�5- 1 ]11 LI N L2 LJ (2)3JA FL5E5 I I j b 1034AS SSIO t --J i I zr A I N ■ EN C 1N 5ERv1cE PANEL PROJECT NAME - ° --- a -------------------------------------------------------------------------------------------- II 1 I E%15TING AC COM9INER BDz 1 I I D(15TING GROUNDING vga;w 4.P I I I I I I ELECTRODE 5Y5TW 0 I I I I I IL I N t emu« I I I I I W U > � I 1 W WIRE#CONDUIT SCHEDULE 0 N ?� CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% W UU--I 0 I.D.# ORIGIN DESTINATION 517E PER POLE QUANTITY DERATE IN5ULATION SIZE QUANTITY IN5ULATION (CU/AL) TYPE 51ZE TEMP DERATE D15TANCE J (n V� - 5(5x2axf3�) W J I INVERTER5 COMBINER PANEL AWG#12 1 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR 1" 55-C V 0.84 1 10 FT 2.8% O 0 OR EMT 0 Ln 2 COMBINER PANEL AC D15CONNECT AWG#10 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45aC 0.95 25 FT O.G% 0 3 AC DISCONNECT MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I° 45aC 0.05 10 FT O.G% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQUIPMENT TO BE U5TED BY UL OR OTHER NKTL,AND LABELED FOR IT5 APPLICATION. #I PV Source Circuit Wire Ampaclty Calculation - CONFIGURATION 2.)ALL CONDUCTOR5 5HALL BE COPPER,RATED FOR GOO V AND 909C WET ENVIRONMENT. [NEC G90.8(B)(I)]: (Isc)'(#of 5trin 5)'(I.5G)= 10.89 A 3-LINE D I A. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS 5HALL BE ROUTED DIRECTLY g Modules per String 9 TO,AND LOCATED AS CLOSE A5 POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. AWG#I 2,a 0.89y'Temp oreDer A = 20.I G A 20.I G A> 10.89 A,therefore AC wire size 1s valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL - COMPLY WITH NEC 110.2G. #2 Inverter Output Wire Ampaclty Calculation Number of Inverters 9 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL Inverter Max Amperage output'(1.25)= 10.59 A Record low temp -I OQC FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACE550RIE5 TO FULFILL AWG#10,ampacity'(Temp Derate)'(Conduit FLIT Derate)=38.4 A Voc Temp Coefficient -0.24976/9C DRAWING SCALE APPLICABLE CODES AND STANDARDS. 38.4 A> 10.89 A,therefore AC wire size 1s valid. C.)WHERE SIZES OF JUNCTION BOXE5,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Inverter Output Wire Ampaclty Calculation DC SYSTEM SPECIFICATIONS THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. Inverter Max Amperage output'(1.25)= 10.59 A Operatinq Current 13.0 A N T 5. 7.)ALL WIRE TERMINATIONS 5HALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G,ampacity'(Temp Derate)'(Conduit Fill Derate)= 72 A Operatinq Volta6 je 30.8 V 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 72 A> 10.89 A,therefore AC wire size is valid. Max.System VoltaL3e 40.1 V SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 17.3 A 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEK LUG OR I1-5CO G13L-4015T LAY-IN LUG. AC SYSTEM SPECIFICATIONS SHEET NUMBER 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5itive/negative) Max AC Output Current 10.89 A PV-5 OR O eratin AC Volta e 240 V 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90.35. TAX MAP: 1000085000200010000 l Zoho Sign Document ID:2A768FFA-TGGXYIZJQNOHG4KDBWOONJSAP-3Q7ZYZ6HPJL2A7MFY DRAFTING BY: SERVICE METER DESIGN 4 1 O7 INSTALLATION NOTE ELEMENT ENERGYLLC ® � SDLARI Pll SYSTEM PHOTOVOLTAIC REVIEW BY J.M.NABCEP CERTIFIE � ( I ) ALL LABEL SHALL BE INSTALLED IN 051I12-128 EQUIPPE SOLAR BREAKER �. IJU ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN OPERATING VOLTAGE VDC REQUIREMENTS. Rev!sloNs 8 - DE5CRIPTION DATE REV (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 04-I2-2024 MAX SYSTEM VOLTAGE VDC SOLAR AC LOAD CENTER- OUTSIDE (� ATE THIS�° •. IT ENT REQUIRE FIELD VERIFICATION. i DEVICE I (3) LABELS, WARNING(5) AND MARKING 03 0 ®TURN RAPDD SHUTDOWN SWITCH 70 SHALL BE IN ACCORDANCE WITH NEC THE'OFP POSMONTOSwTl) N 1 10.21 (5). I PVSYSTEMANDREDUCE , 4 SHOCK HAZARDWTHEARRAY _J ACDISCONPfECT ' ,mnWCujmv=� (4) THE MATERIAL USED FOR MARKING °'�°$M °SOURMM M UST BE WEATH ER RE515TANT, IN SOLAR AC LOAD CENTER- INSIDE �w O Y T I CONTRACTOR ® w I COMPLIANCE WITH NEC 1 1 0.2 1 (B)(3). ® O ® I I �I, I (5) THE PV SYSTEM CIRCUIT CONDUCTORS ELEMENT ENERGY, LLC. I I �� � I 7470 SOUND AVE TMLSEOU;FlIMFOBYldULIKE j DUAL POWER 1 j SHALL BE LABELED INSTALLED IN MATTITUCK, NY 1195 S0URM.TDT� OFAu COMPLIANCE WITH NEC G90.3 1 . LICENSE# 67461-111 0VER �RRoaTDE+neES.pccLUDINe SOURCES:UTILITYGRID 1 LICENSE# 52689-ME MAIN SUPPLY OVHtt URRENT AND PV SOLAR DEVICE SHRiLNOiEXCEED ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING AIAPACRYOFBUWRRW 0F New y 4. I THIS SERVICE METER r y IS ALSO SERVED BY A C) ' ELECTRIC SHOCK HAZARD i PHOTOVOLTAIC SYSTEM : W I I COMBIMF P�� IS SYSTEM y T®21dRIALS ON THE UI�"EAS4D II LOADS/DE MWEEENERGIZED I DONOTADDLOADS �O 703443 CONDUIT - OUTSIDE BUILDING 1.—IN THE OPEN POSITION O ® PROJECT NAME �� •• • 0 O LL- DUAL POWER SUPPLY I ® _ w U LLJ >ES:UTGRDAD SORRYNMPVSU SYST _ MAIN SERVICE PANEL - OUTSIDE TOt�SO C) O I wCz z 0 0 ® �C-�� I• ® n N Q O J SOLARELEC=SYS(EMC08WZJED 11 J N H LU © O In CQ 0 O MAIN SERVICE PANEL - INSIDE POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS 6!' SHEET NAME OVERCURRENT DEVICE --------- --------- - LABELS AC DISCONNECT/BREAKER DRAWING 5CALE 000 (3G N .T.S. SHEET NUMBER PV-6 TAX MAP: 1000088000200010000 Zoho.Sigti Document ID:2A768FFA-TGGXYIZJQNOHG4KDBWOONJSAP-3Q7ZYZ6HPJL2A7MFY Town of Southold April 12th, 2024 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Bellezza Residence, 20 Seawood Dr, Southold NY 11971 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3-second gust, and Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it-is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also, the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.6 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra. P.E. OF NEwy Great Eastern Services, Inc. ��P��o A PO Box 240 * '' cc: ttii rG 24 Harvey Rd 0 w Riverhead, NY 11901 2N •_ z Mobile: 631.235.0189 443 Email: jerrygiustra@gmail.com AR��EsS%(