Loading...
HomeMy WebLinkAbout50703-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50703 Date: 5/17/2024 Permission is hereby granted to: O'Brien, Timothy ��..�w..www.......__.�_._����........... �w.w...._._........._�._..�.__ wwwwww.............. _..,_ww�.�.._ ..._ 1130 Saltaire Wa_y�� _ Mattituck, NY 11.952� ._.�.WW........ _wwµ �...w_ ��.......� .... To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 1130 Saltaire Wad/.m..Mattituck�_.........._....., .............._wwww........maaa.............._. ......... SCTM # 473889 Sec/Block/Lot# 100.-1-30 �...w.._......,.,,,,. w_. _.....�____._............ �. Pursuant to application dated _...-4/5/2024 and approved by the Building Inspector. To expire on ....11/16/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building nspector ff BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD l; Town Hall Annex - 54375 Main Load - PO Box 1179 Southold, New York 1 1 971-0959 Telephone 631 765-1802 - FAX 631 765-9502 ro err southoldtownny,gov and southoldtownn , ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) ®ate: 4*�. t Company Name: 6AeMcn4 Electricians Name: rrt M -n n License No.�: 5 a G q - t-,1 F Elec. email: Pe,�—rn i +,5 �b CID4 j Elec. Phone No: (ZI request an email copy of Certificate of Compliance Elec. Address.: 0 ,So d JOB SITE INFORMATION (Ali Information Required) Name: )im o 1- c ia)'rlt " V Address: Cross Street: ,�,S,o LL I ,,,r_ Phone No.: (Z3 1 ®Lt 9 Bldg.Permit#: email: PfrM4S Tax Map District: 1000 Section: 10 o Block:. 0 a Lot: 03 0 BRIEF DESCRIPTION OF WORD, INCLUDE SQUARE FOOTAGE (Please Print Clearly): jvu Square Footage: Circle All That Apply: Is job ready for inspection?: YES "° NO Rough In Final Do you need a Temp Certificate?: YES ® NO Issued On LJ Temp Information- (All information required) Service Size l Ph E]3 Ph Size: A # Meters Old Meter# ®New Service®Fire ReconnecO Flood Reconnect[]Service Reconnect®Underground[Overhead #Underground Laterals 1 2 R H Frame Pale Work done on Service? 11 Y N Additional Information: _E v15+r_,1.I .�1tA,.sy.y r 0 0� m o�rl+(A ,S0I ckr-PI s<W N, PAYMENT ENT IUE WITH APPLICATION TOWN OF SOC1` HOLD - BUILDING DEPARTMENT Town flail Annex 54375 Main load P. 0. Box 1179 Southold, I°JY 11971-0959 � A Telephone (631) 765-1802 Fax (631) 765-9502 [ ....�.: 4..�.,1A 'o b 11t ")14 II rm, . 'Co, Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. 6 Building lnspectw% Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: it/q/,)-- �_ OWNER(S)OF PROPERTY. Name:--T-l M 0 " ey"I't o SCTM# 1000- o o . O o - 01 . 00 - goy Project Address: I , ID d&-14 a 11c, 06L. „w. 41 _I/• el��� Phone#: G,3 0- c3 9 b - 7 d� ' Email: T ���,rn�l�- 5 '' was �S•Coa1 Mailing Address: CONTACT PERSON- Name: Mailing Address: -7 41 o S Odd 61Vf-.,- A-I--I'► a f 161 5� Phone#: (.3 1 -3 p 9 .-?O q l Email: ftrf445 e, <,- „'s ,5 yr9 DESIGN PROFESSIONAL INFORMATION. Name: Mailing Address: m Phone#: Email; CONTRACTOR INFORMATION-. Name: EAe tn6n i Yi�� ��l-�✓ Mailing Address: 104 ------------- Phone#: Email: .� `v V Cl • Pe w s 0, t./o.,s 4J $ " ° • DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cot of Project: ether 0 �5 )AJ" PV 6 _._. $. ;_ Will the lot be re-graded? ❑YesANO Will excess fill be removed from premises? ❑Yes�Vo 1 mmr.wmm �wimm. PROPERTY INFORMATION Existing use of property: Intended use of property: S Zone or us istrict in which premises is situated: Are there any covenant's and restrictions with respect to IV this property? ❑YeNo IF YES, PROVIDE A COPY. " cif Sox Aften, Reading' The owner/contractor/design profeWonal is r spoAslble«for all drainage and storm water Issues as provided by Ater of the"town Code. A.PPLICAInON IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building,zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Lorraine ®I Penta ®Authorized Agent QOwner Signature of Applicant: Date: STATE OF NEW YORK) LOUIS J ROMEO Notary Public,State of New York SS: No.01 R06314813 COUNTY OF Suffolk ) Quaillied in Su� 0' k COUlty Commission Expires I I ven�ber'l7'„20 Lorraine DiPentaZf l � e being duly sworn, deposes and says t (s)he is the applicant (Name of individual signing contract) above named, (s)he is the Contractorwww_w_wwwwwww_ (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of Y�iCu—C.� _ 20 Z4r otar'y ublic LOUIS J ROMEO Notary Public,State of New York No.01 R06314813 IRROPIE IRTY OWNER AU FI,,,1 RRATIO Qualified in Suffolk County Commission Expires November 17,2074(Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. � _ L Wner'sreWW _ _...._ to LOUIS J ROMEO C).by-,ckj Notary Public,State of New York No.01 R06314813 Print Ow 's Name Qualified in Suffolk County Commission Expires November 17,20,;�C 2 - Workers' Cocnu ensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1 To be cam feted by NYS dtsabili an _.� carrier o .... ....._.insurance 1a Legal Name&Address of Insured(use street address only) Family Leah.Business sTelephone Number oafInsured ante agent of that arrle ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK, NY 11952 1c.Federal Employer Identification Number of Insured or Social Security Number Work Locatior of Insured(Onlymquired ifeaverage is specdcallylbnded to certain locations in New York Sawa,ie.,Wrap-up Policy) 823336604 j 2 .,.., g Pr Requesting of Coverage 3a.Name of ... _... � _... ..` .Name and Address of Entity Ft _, rn w..... 9 Insurance Carrier (Entity"rig Lasted as the Cerfif ate Bolder) ShelterPoint Life htsurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"ta" SOUTHOLD, NY 11971 DBL567527 3c Policy effective period 01/0112023 to 12/31/2024 4. Policy provides the following wraefits: ® A,Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only- S. Policy covers: (M A.Al of the employers employees eligible under the NYS Disability and Paid Family Leave Benerds Law, 0 B.Only the following class of classes of employer's employees: Under perusity ,o'perjury,I cor ity that I am an authcarri rt far tatwe or ii rat of the Insurance cattier re era+nced above and that the named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/10/2023 By Ue 4t - iS arure of insurarce carriers authorized representative or 11105 ucersed Insurance Ageat of that insurance carrier) Telephone Number 1 Name and rue Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that tamer,this certificate is COMPLETE.Mail it directly to the certificate holier. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 6200,Binghamton,NY 13902-5200. PART i To be-completed bY...theN._YY..S. Workers Compensation Board(onIyif sox 4_8,,.4_C. o_r_.56 ..h._a.v._.e.�been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Articfe 9 of the Workers'Compensation Law)with respect to all of their employees,. Date Signed By i5igrratore at Authorized NYS Workers'Compensation Soard Employee) i (Telephone Number Name and Title agents oft ose insurance carders licensed to wnte NYS disability and paid family leave benefits insurance policies and NYS licensed insurancemmm W W Please Note:Onl• insurance Carriers h are authorized to issue Form D8-120.1.insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 1 Jill ire si � i i ii l .a� `',I CERTIFICATE OF LIABILITY INSURANCE °ATE'""M7i1lD°2ro�i3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy([,&$)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terns and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsome S). PRODUCER ROBERT S. FEDE INSURANCE AGENCY '°" PHONE 23 GREEN STREET,SUITE 102 141,. _. _ ....... .. .__....wI191aw..�_. ... HUNTINGTON, NY 11743 LBO_ ._..M...._....�.._----................... ROBERTS.FEDE INSURANCE OUS)A r D oc��E__,, NAICa AtILANTIC INSURER A, CASUALTY INS.CO. V524214 Element.._._� ,.._.....M _..... _... .... r �� Energy LLC c.m . r0 - DBA ELEMENT ENERGY SYSTEMS _"""' m"'"' R.o.GLN' �L .......S fAR�'NAbME1T'�vwvw .... _.... 3TfS2 _"_ 7470 SOUND AVENUE MATTITUCK, NY 11952 01SURE.....,FtE. NNSURER r: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERRA OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, _�_..EXCLUSIONS CONDITIONS OF SUCH AND CON PO LICIES-LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS...,�w..._ . , ._.,..._..... ., .. .,.....,.._.. r r INSURANCE AISt0 WVD aor uCY NUMBER MOODI f I,(AKwo .'YYw urlrs TYPE OF IN COMMERCIAL GENERAL LIABILITY L1480036873 EACH OCCURRENCE a 3,000,000 A x X 7t14F2023� 7I14l2024 _ CLAIMS-MADE OCCUR earl _. a ._... 10D,000' tMa3ss2o36 rwE�Exa � xµ _ ?I _.w.Contractual LiaN.... 7/19/2022 7119/2024 PERSONAL&AOV INJURY s �3000000 GBML AGGREGATE LIMITAPPLiES PER PRO- I oHauE.A A. k ..... : ,001�,00tI POTOLICRY KI JECT LOC PROoUCT3 iDP - t HE ; 5...,._.,..,, . . AUTOMO6ILLE IIABKJTYSID S _._..._w ...... ANY AUTO BODILY INJURY(Per person) f OWNED ...�,,SCHEDULED ......."..m......... .........W,..��........,,........_..ww....,w. .._.,. ._�.m.�.........w........ AUTOS ONLY A"os f BODILY INJURY(Per 3a6ent) S HIRED N f ....._... .........�...._...._...�,. ,..... ON OWnD AUTOS ONLY AUTOS ONLY I�6 A rY OAAtAG'" 1 �- �,.,._ .I,_......,...�­ .,_____.._................................ ......._...,......,.�...,.,.__...... 8 UMBRELLA UAB OCCUR E11Ch1 CCC4.IiRE�4C.E. EXCESS uAB I t AA�tAF+r3E _ . ...a AGGREGATE 3 DEEI RE"rENr'p !t t coweNsAwst t ANtI EMPLOYERS' Amr#4UABIL TY Y t N 124494445 7A 312023 7/131'202d 6'Yt�. DrNte NENId'EXECUTICIsE N i A E L EACH ACCIDENT S 1 �OFFICSR#*w*ReXCLk4*w I ....g ..,._..,.,.,.....�..�....a...... tM� l'In NF7 EL DISEASE-EA EW@PW.CYFd i CRtPTMTONuMet E.I.DISEASE-PC LIMIT A NY State DBL D$L567527 1141l2023 12/3112024 Statutory DESCRIPTION OF OPERATION$!LOCATIONS I VEJOCLES IACORD 101,Additional Remarks ScMduie,tray be atlaeft"It mom spate is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 34 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE PALL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WtTH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATNE RC S. FedR, Q 1988-2015 ACORD CORPORATION. All rights reserved. Ai—^Dn)C il)AIArnit Ts,s er-non.._.....,,,.�I....,, —4 A ^M, NSF New York State Insurance Fund PO Box 66699,Albany,NY 122C6 J nysifcom CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) AAA^A° 923336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD 4-5 DATE 12449 44 389075 07113f2023 TO 07113l2024 7111l2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5. COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT NTTPS:ffWWW.NYSIF.COM/CERTICERTVALASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT U NCE FUND 4 �V DIRECTOR,IN SURANCE FUND UNDERWRITING ' ENPHASE Ouir r Hewes'<.i0-3 sMicroinver"3rs ars ;r dusF:rv's Jim.-:?tip"o jrid-i Jr-mi tg,vL'7wars- - and,',omvacT with! Je lned 1iOrOir-�Jer_aT3.pJi',-,.3t,i3i-ti/a.u� o,,veF=,var.31 r,sacabii!$•f to�;onvq'DC Plug-r-'pizv-- rrec'Iion E'7w6F to.AC,rot7LiteT a'sideflt: - :`'re oafs'?'�`'`i'16 seFrliCfJllduc or--sase+ TICIOEg'+.�le!"'3l -'�fl�t°3$`_:4'tE•:}�fY¥1asT:3C33: is OJT• T'J.7r!2t3rJ aua9cas oF'-SCeCit"I i3'1T.e-orates CiTo:iit'.> ie:.., !tih eTlaGieS' 6 aym ; ....'beT'weeir--crjF$l> cry eras frliCFO$rly2rieT'iC oY3^eTa'em T "G 'E Cic. i- aF v5nn ?£8d tsci�noia-,�kYi h aces 1igfta;logic and�as super-'fast response tries a.-ker r?sta0afior Mth 353TiF#e 'o pit=._rlgis.g!beds aiIc:grid avc-r-,&s.aiille`J?a-Lirlp oast jints on d---Cer'i Sizir.g our home �Y� 15Ai� 2�ilF en•E3Fg~/systisms. 1°49';w �mdF P.-S.—Ice rGw---T 9T#a-, R3!'?s✓ ..'j?6 gFic'is:E5w' %1 MoFa ag1 or1--ftsii�or cuii uiative curs o;7estvg 'J• r _ '; ;ke3��s5++�-"sue Part o ld,.eEnphaseEnergySystsrn,iC8Seriss tog'Series.Wcrainroer+s�s;ereSnen ability e Mcroimeerters integrate wrtr!the Fnphase'C Battsr;t standards'uiif;more tisan one million cumulatve _ SBI9EFZ r rT€6 is S'e; cnphase IQ Gateway,and the P-nphase App monitcring hours of power-an testing,enabling an industry- and analysis software. leading limited'rarraniy of up,to 25 years. PoweiredOtt-noduSES r�gMIIM1NMMNW advanceztgfrldsuppc t** ° Rernota autorinlatt updates For the west grid reqUirgMents Connect pV modules quickly and easily to IQ8 Series IQ8 Series hiicrcinvertevs are Ut_Listed as 9 Microirrverters usingbhe included Q-]CC-2 adaptor pV Rapid Shut Equipment 'le Tc support a' 6 � P� q pment and conform�,atYh• cable with plug-n-play MC4 connectors. various regulations,when installed according to range QT grid¢softles, manufacturer's instructions. Meets CA Ruf6 2I CUI 1741-3ad; r9quir-ar-nents '0 2022 Enphase_;ner91r.All rights raser,ed._np-ase,•:he--rpl-,ase%ego.!C8•,WCroirder*ars,and orher Only un=r.:nsialled.roiih!Q 3,estem Controller 2 names are tradema,,,a of Enpnase=rergy.inc.0aia;udiect_c-range.g meets UL 1741. I08 and:08alus supports split phase.24G4 �nstailaticrs oror. 1Q8 and 108+ Microinverters Commonly sed-nodule pairings' M 235-350 a 235-440 6C-cell/12C r.aif-cell E&ceil/Q2 ail`-cal arc,72-ce.-!,'It" Uccuie cci-,,Patlhli t" 60-cell/120 half-celi raii-ceil MPPT voltage range d 27-37 29-45 Gperatirg range f 25-48 2 5-5 B Min/max start voltage V 30/48 3G/56 Max;nput DC voltage V 50 60 Max DC currer?[module sc a 15 Overvoltage class DC port 11 BC port backfeed current nA 0 PV array configuration Ix1 Ungrounded array;No additional DC side protection required;AC side protection requwesmax 20A per branch circut Peak-output power VA 245 300 Max continuous output power 4A 24C 290 Nominal(L-0 voltage/range" V 240 211-264 Max condrucus curpul current A i.c 21 Nominal frequency Hz 60 Extended frecuercv range Hz 50-68 AC short circuit fault current over 2 3 cycles arms Max.snits per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% class AC port III AC partback-feed current MA 30 Power Factor setting 1.0 Grid-tied power factor(adjustable) 0.8.5 leading-0.85 lagging Peak efficiency 97'5 97-6 CEC weighted efficiency 97 97 Night-time power consumption MW 60 Ambient temperature range -40cC to 44800C(-40OF to+14001`) Relative humidity range 4%to 100%(condensing) DC Connector type MU4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1-21 Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure Environ.category I UV exposure rating NEMA Type 6/outdoor ............. .............. COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CffCSA-C22.2 NO.107J-01 Certifications This products UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017.and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Skutdowr,of PV Systems,for AC and DC conductors.when Installed according to manufacturer's rstructions. (!)Nc ir�crcec0c/AC' a-dc 3ee!k-e -,rmpatib�MY",'alculpjLc�r al npul DIC,uuf rig, fG 9A(',)i Ncr,ir /citage rarqe:,ar xlerded er.,a,Vred C0 -CS-CC - 1-PKI-US2C'2-2-C a ' ' r r IRONRIDGE .l r r �yr�Nr; r�% rp1 � n r rr rfrtr "�° Irr.r ter. rr � � "gum a r "R"%r ,r r r%ny itiF r � Iro Riche builds the strongest 71iouni:ing system for pitc'ned `loofs in solar. Every component lcs been tesle i to the limit and Proven rn extreme environments. eats. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. I uuwG� N Strength, Tads d PE Cerfi ead ii �" r All components evaluated for superior Pre-stamped engineering letters i rrffr/r y r �IN �� r%rs;,, structural performance. (rir/��r/���i��; available in most states. N)TV Design Assistant C�ass A Fire Rating / Certified to maintain the fire resistance , Online software makes it simple to rating of the existing roof. % r,,,,, ?' create, share; and price projects. L 27,03 Lista,d Syste r 20 rear W rr rif 'r ti1rn "— `1 t,� �"''a"r`.v ' '�`..fl�".i m� 4. '!I/�'✓v 7r;ti Y7,"tJ� l.+rlfi � (.�� ✓'^_,.y r pia.e sy` ca „ � p e y to f. XRRQQfr,m�u1 Xi i t Jit7+( tt ;,it f3 Ir::PJ. r.i va} Pir„ :; sw�wrw� , rrr°�� nti�e MC,',J,ting roll he ultimate residential `Vlt srlcw !� {ie ;'/ G f t^ mb &q 6 4 1 I lzi& use `rto�rr°aid ��Itit S 50iar rrid�ntln all. 9 rail for ccrnmer ,,jai p r,,,awWts J�"'ra nning capability 8'Spanrllng capability 12'spanning capabifih,, Self-driliiir;q Moc'je,role r( ad capabii6t'>f Heavy load capability fi E reme lead Capabil r. ity Va,yirrg ver:�,d��s fcr rails „ Cie<s,r and black �tinish �", Ceear and black finish � Clear anodized finish Forrr,s s�eci_ira bonding 4rit� r ....... . "Grolunding Lugs r f"�rC.raC Y rig ot'.'ac ry '`. +�. ww..,.. W+....,.w. ....,w... . .ts Snap onto the ;_FO to turn � � Corrfi 7" dules r aslS ���,�n'�s to Amount I��lls or 'cis io ,�R ntc d bondgd dinri Clamp r r aclui�nnent ground, Rails. F uily assem.cied & I bid Bonds (nodules tc ra,rs �n�, g1e i'B a a, S;Z � 3 ;,t_, �tl �r0±'.le Bonds evidds to Taiis 7 c td r a,ch rnodules Single tdoi ?nstallaricr' Clear and black, rinisi C K=.t comes assembled ldar and black iantSi �tdissnts ir': any direC lCr Lis-ted. to Uv 2703 t aft d�rnrg Harrdware F i r l Flash Frithsuperior dmonXPails Fla '""add mount conduit, - sign for rapid rail Bond and attach XB Rails or junction boxes. attachment,waterproofing. to roof attachments. Twist-on Cap eases-inst j1 ° Tuirist-on Cap eases install Secure rail connections Wind-driven rain tested �ATind-driven rain tested � Slot for v rtical ad ustin T;� Square Bolt options Mill and black finish 3 » adjusting Nut Uses 7/16"socket Secures /� or 1"conduit Clear and black finish ° ,assembled and lubricated Ass;'Ist !n"t MA C-EP �r�rfi fir�cd fr 1�7�trl�� GG 'from rough iaycut to f�illy Earn free continuing educe'ani n credits,syqterr For „ nary Technical TnfoXrrr'ation Sheet r CanadlanSolar r 0 , (All--Black) ALL BLACK MONO PERC 9 I r 15 m MORE POWER 1 5 Industry Leading Product Warranty on Materials wears d and Workmanship* Module power up to 405 W Module efficiency up to 20.7% 25 Linear Power Performance Warranty* t"eau; . Lower LCOE&system cost P°year power degradation no more than 2% Subsequent annual power degradation no more than o.5s% pIDp�.�p TID y -Subiect�ro the terns sand caand"an"c'o nrxoed rn iho appsEtat Car adian Solar Limited Comprehensive prehenslve LIU.r P L,e Y RC,M mitigation Kim tA('�n arra nt'y nreBeMN94,�,/Y,t.Arso this2'.�w,�1ear k{p' teoi Prod,�4,pa^x arrarkRy k5 ddvWlable only for prod- " g gat is InStaaded and operaaung or resartfertmu,cua r"raeRPttrµs rr errrtam rec�ues, technology, up to 50%Power degradation rro MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:201 S/Quality rn,mstageartent S; terrd Better shading tolerance I50 14001:2015 7 Standards for envaronrnental management system fSO 45001:2018/lnternaboriM standards for occupational health&safety MORE RELIABLE PRODUCT CERTIFICATES* IEC 61 15;IEC 61730/CE/INMETRO UL 61730'IEC 61701/IEC 62716 Take-e-yray Minimizes micro-crack impacts SA v JE . C cisko -wcx «No sVorifur w ar d 4:a4trr°^;uG'@pd6rC,t4utr;^rdrr d dif,"rrror aallywr e ZVPE%and ar a^t;et r ww+tl1 w»ta7„ Heavy snow load up t0 7000 Pa, ro'pr4 rtw ra rtpre dpot 30 of the reor,tacarter, iceared Ew�a� 6gpq s'mmull,arr eery^%ly apWy p a:hdd .., wind load Up to 5000 Pa* p lodurtsyttak order or"s,e.late„ase colltact your a0,l Carkadb ao soi,ar>ates reel seurtauve kQ cronficrer lie sg m-pt r crtrrfCa qC a..«ava,hwtrle rarrr yeas P(Or&tdat„rd agptWdt:ulabk n the,eip.rs in whlch ow parerio,:rs MH be issed, CST SOLAR(USA)CO,, t,TD,is committed to providing high quallpy solar photovoltaic modules,solar energy and battery starage solutions to customers,The corvaparsy was recognized as the No,1 module supplier for gu alaty and performance/price ratio In the lhlS Module Custorrler Insight Pending Ewing can rrratior For Je:allerJ rfcrrrr, t:vn. Survey,Over tlW past 20 years„it has Successfully deliver.ed over '7 f u?35 rErE'r.0 rnP Ir lTallacipr ruler,:b i. of prernium•cluailty scalar modules across the world. CSi SOLAR(USA) CO., LTD. 1350 Treat Blvd.Suite 500, Walnut Creek, CA 94597, USA www.CSisolar.com/na I service.ca@Csisolar.com ENGINEERING DRAWING(mm) CS6R-400M5/I-V CURVES Rea, ljiC,r w a "r rr°mr C"Ila I °v mice 4,,A 13 � " � � of � - iz , mown"';;dI r � , Vr�ar.'w i^rg r�aaie a iy ..5', i .....,. _�................. S 70 IS 20 L 36 Js 4+5 is'.ao 55'� .5'10 75 20 2.5 an is al,)45 so 55 fio IDog wllar 5'r' rah� 25 c: _ � I err- WWII, 4s'c It B _..... 200 wrr,,, 65 c a ELECTRICAL DATA STC* C s6P MECHANICAL DATA 3130MS 38SM5 390MS 39 MS 40OMw 105MS Specification Data Nominal Max.Power(Pma,x) 3I10 W 385 W 390 W 395 W 400 W 405 W Cell'1 e Yp g Mono-Crystallline - Opt,Operating Voltage(Imp)300.0 VA 30 27 A 10A A 10,6 V 30,8 0 8g A 31' V Cell Arrangement 1722 10 (2 X(0 3t 6)l Voltage Vm ) V 31 2.84 Opt,Operating C 91 A 6'a 9� .07 A Open Circuit Voltage(V0Q 36.0 V 36,2 V 36A V 36.6 V 36, V 3`'.0 V Dtmenslons 7-8 x 4.6 x 35 mm Short Circuit Current(Isc) 13,55 A 13.63 A 13.70 A 13.77 A 13.L1 Al 3.93 A Weight 21 3 x 4476 x 1.38in) Module Efficiency 19.5"% 19.7% 20,0% 20 2% 20.5% 20.'7% 21.3 trim, (47.p ibs) Operating Temperature -40amC;-*85*C Front Cover 3e ream tempered glass with anti- Operating System Voltage Frame reflective,ca4tdvvg - -- or 1000V(IEC/UL) Anodized paluminium alloy, - SOON(IEC/UL) Module Fire Performance TYPE 1 UL 61730 150OV)or TYPE 2(UL 61730 9-Sox dP68,3 bypass 1000 or C S C(IEC 61730) Cable 4 mm2(IE ,12 AWO(UL) Max.Series Fuse Rating 25 A Connector T6 or MC4 series Application Classification Class A Cable Length 1550 mm(61_0 in)(+)/ Power Tolerance 0—+10 W (Including Connector) 850 mm(33.5 in){-)* d.lrmrrea Standard Test Conditions(STC)of irradiance of 7a10 W/m spectrum A1Lt i.5 and cell ternpe- Per Pallet ratureof 'C- 30pieces Per Container(40"HQ) 780 piece's For,tdecl#jed Informaticon,pi"A.A conract galua local t_anadian sIxar safes avid tecive'rgod a+fg5a"esenrafiw,t. ELECTRICAL DATA I NMOT* C.S6R 390M"S 38SMS 391114E 39SM'S 40OMS 405Ms TEMPERATURE CHARACTERISTICS Norrcalnai Max.,Power(Prnax,) 264 W' 286 WW 291 W 295 W 299 W 303 W �3 a rr'otr,strir°an Opt Crperadng Voltage(Vmp)2 .1 V 28,3V 28 4 V 28,6 V 283 8 V 29.0 V Data Opt,Operating Current.('Imp)10.12 A 10.'19 A 10,26 A'0 0,33 A 10,39 A 10,45 A Terrperature Coefficient( oC) 0.34%/°C Open Circuit Voltage(VoC) 33.9 V 34A V 34.2 V 34A V 3�4.6 V 3,1 7 V 'enlpe`°at°�rf Coefficient 1''VC) .0.26%11C Short.CirCU t Current(I C) 10.91 A 10,98 A l 1 05 A 11,11 A 11.t 7 A 11.23 A Temperature Coefficient(Isc) 0.05%/'C Under N erN mgairMotal'�deo rating Tem"tpernN"no(s` oa').dr"ad"ariceor O'Ailto=wperrmumAMt.5. Nominal Module Operating Temperature 42t3'C arnbkeottemperaaawa 8fk W'Ad serried#Airs. PARTNER SECTION "l't sioecniar;tt"ena mataf aey'eatures COntalned In II&dac�mhewl vnayw.bam;ajtat,0,q rly From 0N,'ottj'11 amdoms due to lire oro1009 onroarvaation and Product enhancernent,t(4)s0lilf(o,�Ltat reserves it,m right to indke n4Kt453ryadius4rerq To rime inforrvaaYmea�ry described hereiru at ar�,y nine w g rout Rttttn nonce. er P'41UKe be k«idly advised that Pv modwes should be hardIed and iOSTMlee by quaW-cd people wvno have professional skills and please carefully read the safecy and ni n'3ld4t,on instructions before using our Mn6Ir,odaaQes. CSI SOLAR(USA)CO.,LTD, June 2022 1 All rights reserved PV Module Product Datasheet v1.5C25_F23J2_NA Page 1 of 2 VV'lf� TJY-1— �3 f 04/03/2024 Current ReneWables ELEMENT ENERGY LLC. Engineering Subject: Structural Certification for Installation of Residential Solar Job: Timothy Obrien Residence Project Address: 1130 Saltaire Way, Mattituck, NY, 11952 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of ELEMENT ENERGY LLC.. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, IEBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 127.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A Exp:09/30/2025 .�tof NEW), �O�RT A. lgoO�� Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com Fop 106793 FE NP Signed on:04/03/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 'info@currentrenewableseng.com Page 2of2 Summaries: Check 1: Shingle roofing supported by 2x6 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 20 degrees and has a max beam span of 16.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13,Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com s ROOF MOUNT SOLAR PERMIT PACK_ AGE AR co INFORMATION THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC TIMOTHY 0 B R I E N POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2020 BUILDING CODE OF NEW YORK STATE W YORK STATE 8.800KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020EXISTIRESIDENTIALBUILDIDECOD OF EOFNEWYORK 2020 EXISTING BUILDING CODE OF NEW YORK STATE 1130 SALTAI RE WAY, 2020 MECHANICALL COODEDE O OF MATTITUCK, NY 11952 2020 FIRE CODE K STATE F NEW YORK STATE 2020 PLUMBING CODE OF NEW YORK STATE 2020 ENERGY CONSERVATION CODE OF NEW YORK STATE 2017 NATIONAL ELECTRICAL CODE BUILDINGINFORMATION THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 1 STORY HOUSE SINGLE FAMILY RESIDENCE ACCOU NT NO : 9887503305 EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY:R3/U METER NO: 98303037 AHJ TOWN OF SOUTHOLD RENEWABLES ENGINEERING INC. ROOF:COMP SHINGLE APN:1000100000100030000 : PV SYSTEM SUMMARY: WIND SPEED 127 6 Current- SYSTEM SIZE(DC) STC:400 x 22=8.800KW DC SNOW LOAD : 25 ReniewableS PTC:376.70 x 22=8.2874KW DC EXPOSURE CATEGORY D Engineering SYSTEM SIZE(AC) : 6.380KW AC @ 240V �w.c�OF NE{y�,O CURRENT RENEWABLES MODULES (22)CANADIAN SOLAR:CS6R-400MS-HL oO�RS A' �q� �� ENGINEERING INC. 1760 CHICAGO AVE SUITE Q J-13,RIVERSIDE CA 92507 _ PHONE:(951)-005-1733 NNJW.CRENG.CO MICRO-INVERTERS ENPHASE: ICI8PLUS-72-2-US I W AERIAL VIEW VICINITY VIEW CONTRACTOR.INFO MICRO-INVERTERS CITY 22 2 TILT 20° ��`� 106793 AZIMUTH 60° p'�OFESSIONP� '+ t ROOF COMP SHINGLE RAFTERITRUSS SIZE : 2"X6"RAFTER @ 16"O.C. Exp:9/30/2025 _ E2SYS� ATTACHMENT TYPE IRONRIDGE HALO ULTRAGRIP WITH IRONRIDGE Stamped 04/04/2024 XR-100 RAIL ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, MAIN SERVICE PANEL EXISTING 200 AMPS MSP WITH 200 AMPS MAIN +� ' NEW YORK,11952 INTERCONNECTION BREAKER ON TOP FED ( ,i /,f services@e2sys.com : PV BREAKER OCPD RATING --- -- ly f Licence-ME-52689 40 AMPS (MASTER ELECTRICIAN) Licence-HI-67461 UTILITY LONG ISLAND POWER AUTHORITY ( SUFFOLK HOME IMPROVEMENT) GENERAL NOTES: - Solar Individual a �I J 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION r� - '.` ' Permit Package 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES SHEET INDEX TIMOTHYOBRIEN 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 - -- - PV-1.0 COVER PAGE 8.800KW Grid Tied 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.0 SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS PV-2.1 ROOF PLAN 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL 1130 SALTAIRE WAY, GROUNDING ELECTRODE PV-3.0 STRUCTURAL MATTITUCK,NY 11952 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS"- PV-4.0 ELECTRICAL3LD Rev Description Date 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS P 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" V-5.0 ELECTRICAL SLD A INITIAL DESIGN aiaizoza 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC. PV-6.0 BOM 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35.- PV-7.0 ELECTRICAL PHOTOS OPPORTUNITY TIMOTHY OBRIEN 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. PV-8.O SIGNAGE PROJECT# TIM 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 9002 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND.INSTALLED PER THE NEC,THE INSTALLATION PV-8.1 PLACARD DATE DRAWN 4/412024 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DRAWN BY E.R 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8"ABOVE ROOF SURFACE. PV-9.0 MICROINVERTER CHART SHEET# PV-1.o 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE;TYPE NM CABLE PV-10.0 SAFETY PLAN TITLE ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0 SAFETY PLAN COVER PAGE 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: PV-12.0+ SPEC. SHEETS R324.6 PATHWAYS: NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON WIND SPEED : 127 LEGEND SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON SNOW LOAD 25 ALL BUILDINGS. AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR EXPOSURE CATEGORY D UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. (`QF NEw FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM AA� 361NCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE `r RT A. �� MSP MAIN SERVICE PANEL E SHALL BE PROVIDED ON THE SAME ROOF PLAN OR STRADDLING `�Q THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE * * COMBINER OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROORPATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR r 1� MECHANICAL EQUIPMENT. _ ❑ MODULE R324.6FORP.2sErBACK AT AICARRAY: ROOF OBSTRUCTION ��` 106793 t�� ROOF OBSTRUCTIONS FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 Q V O PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN r AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A �Or ESS ROOF ACCESS POINT THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. ROOF ACCESS POINT COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 (N)COMBINER Exp:9/30/2025 REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A (E)UTILITY METER Stamped 04/04/2024 WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. PROPERTY LINE' p RENEWABLES ENGINEERING INC. (E)MAIN SERVICE PANEL R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED 200� SHED Current THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE -----� pelf��S�C�{�1e5 PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. -------------- --- -�-- -------------'—'----------------------- IY 17 A -PATHWAY ON STREET Engineering OR DRIVEWAY SIDE OF ROOF B -FIRE ACCESS POINT CURRENT RENEWABLES I ENGINEERING INC. WENIImAr 321—�11 1 PHONE: E:(951-0 SUITE a7 1 J-13,RIVERSIDE CA 92507 36"ACCESS PATHWAYS i I PHONE:(951)405-1733 1 1 W W W.CRENG.CO 18"ACCESS PATHWAYS ' Q I I CONTRACTOR INFO 1 d. • i NOTES: ' 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ' 1 ON ACTUAL SITE CONDITION AND LL) �1"DRIVEWAY MEASUREMENTS. I•: ° °• .. 1 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS a CcSYSu INCORPORATED INTO THE 2017 NEC AND UL I . STANDARD 1741. i 3. EXISTING ROOF VENT SHOULD NOT BE Q I I ELEMENT ENERGY LLC. COVERED. 1 _ 7470 SOUND AVENUE,MATTITUCK, i NEW YORK,11952 CD NOTE: PH:(631)779 7993 NO FENCES OR GATES SURROUND THE PROPERTY I i services@e2sys.com I I O Licence-ME-52689 O �� 60'-1" I r' (MASTER ELECTRICIAN) 1 Licence-HI-67461 109' —I (SUFFOLK HOME IMPROVEMENT) i I Solar Individual Permit Package 1 i TIMOTHY OBRIEN 8.800KW Grid Tied 1 L-------------------------- -- -------- ------------------------------------ -----------J Photovoltaic System 2001 I 1130 SALTAIRE WAY, MATTITUCK,NY 11952 ROOF LINE PROPERTY LINE Rev Description Dale ROOF ACCESS POINT A INITIAL DESIGN 4/4/2024 OPPORTUNITY TIMOTHYOBRIEN PROJECT# 9002 DATEDRAWN 4/4/2024 ITE PLAN DRAWN BY PV- D__§S(CALE: SHEET# PV-2.0 9 TITLE 3/64" = 1'-0" SITE PLAN ARRAY AREA LEGEND , EAVE TO ROOF ROOF TOTAL ROOF ROOF TYPE AZIMUTH #OF RIDGE ARRAY AREA AREA AREA AREA MODULES DIMENSION (Sq.Ft.) (Sq.Ft.) COVEREDARRA %))Y COVERED( )Y UM UTILITY METER #1 COMP SHINGLE 60 22 15.7 462.44 1863 24.82 24.82 MSP MAIN SERVICE PANEL STRUCTURAL NOTES : c❑ COMBINER 1.THESE PLANS ARE STAMPED FOR STRUCTURAL CODE (N)COMBINER COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE (E)UTILITY METER MODULE PROPOSED PV INSTALLATION ONLY. 2.THESE PLANS ARE NOT STAMPED FOR WATER O ROOF OBSTRUCTIONS LEAKAGE. 3. PV MODULES, RACKING,AND ATTACHMENT THESE DRAWINGS ARE SUBJECT TO C UM COPYRIGHT PROTECTION BY US LAW. COMPONENTS MUST FOLLOW MANUFACTURER REPRODUCTION IN ANY FORM IS MSP (E)MAIN SERVICE PANEL EXPRESSLY FORBIDDEN WITHOUT PRIOR GUIDELINES AND REQUIREMENTS. WRITTEN APPROVAL FROM CURRENT 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL - RENEWABLES ENGINEERING INC. CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. .`��F NEw 5. PRIOR TO THE COMMENCEMENT OF WORK,THE SOLAR ,`Q' Rj A. y0,p INSTALLER SHALL VERIFY THE ROOF FRAMING h o0� �4a Current INFORMATION BEFORE INSTALLATION AND NOTIFY THE yt yt Renewables E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE Engineering VERIFICATION AND THE FOLLOWING:2x6 RAFTERS @ 16' n W OC SPACING WITH A MAX UNSUPPORTED SPAN EQUAL TO 2 = CURRENT R G INC. LES OR LESS THAN 16 FT. M�///_3�' ��`� 106793 �_� ENGINEERING INC. 1760 CHICAGO AVE SUITE AESSIONp� J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 W W W.CRENG.CO ROOF#1 Exp:9/30/2025 CONTRACTOR INFO Stamped 04/04/2024 nA E2SYS Stamped 04/04/20 Q ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 W services@e2sys.com Licence-ME-526B9 (MASTER ELECTRICIAN) Q Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) J Q Solar Individual N Permit Package 1'-6° TIMOTHY OBRIEN -- 8.800KW Grid Tied (N)#22 CANADIAN SOLAR: Photovoltaic System CS6R-400MS-HL 1130 SALTAIRE WAY, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 4/4/2024 OPPORTUNITY TIMOTHYOBRIEN PROJECT# 9002 3' DATE DRAWN 4/412024 RO O F P LAN DRAWN BY PV- 2 SHEET# PV-2.1 TITLE SCALE: 118" = 1'-0" ROOF PLAN ROOF ROOF ROOFING FRAMING FRAMING OC PENETRATION MAX MAX NO TILT TYPE ATTACHMENT TYPE TYPE SIZE SPACING PATTERN PENETRATION SPACING OVERHANG ROOF 1 20 COMP SHINGLE IRONRIDGE HALO ULTRAGRIP RAFTER 2"X6" 16" FULLY STAGGERED 48" 24" THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR ., WRITTEN APPROVAL FROM CURRENT - RENEWABLES ENGINEERING INC. Current Renewables Engineering CANADIAN SOLAR: CS6R-400MS-HL CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE IRONRIDGE XR-100 RAIL TABLE PENETRATION PHOE:(951IDE-1733 CA 7 PHONE:(951)d05-1733 GUIDE FOR INSTALL WWW.CRENG.CO CONTRACTORINFO TWO OR MORE ROWS OF PANELS 11 4" (E)COMP SHINGLE z.s^MIN'EMBED. IRONRIDGE HALO ULTRAGRIP C 2 S T Sv I I I I I I I I I I I I II I9I II III III III III III III III III III III IIII IIII IIII IIII IIII IIII IIII ELEMENT ENERGY LL NERGYLL C . UCK,7470 SOUND AVENUE,MATT 2-#14 X 3"X RD STRUCTURAL WOOD SCREWS TO NEWYORK,11952 EXISTING RAFTER PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER (E) 2 X6� RAFTER@ 16' O.C. 71 0 NEW i (SUFFOLK HOME IMPROVEMENT)ENLARGED VIEW r=7 AN g- =r!4 !T==A E:tT '=p P r= Licence-HI 461 STACKED STAGGERED FULLY STAGGERED A. lq 0 Solar Individual Permit Package IRONRIDGE XR-100 RAIL ONE ROW OF PANELS r a-_ TIMOTHY OBRIEN IRONRIDGE HALO ULTRAGRIP �u I CANADIAN SOLAR: CS6R-400MS-HL I !- -- 8.800KW Grid Tied 106793 SEE ENLARGED VIEW AR�FESSIONP� I I I I I I I I I I I I I Photovoltaic System I I I I I I I I I I I I I 1130 SALTAIRE WAY, Exp:9/30/2025 MATTITUCK,NY 11952 \ Stamped 04/04/2024 FULLY STAGGERED STACKED/STAGGERED Rev Description Date (E)2"X6" RAFTER@ 16"O.C. ` A INITIALDESIGN 4/4/2024 OPPORTUNITY I TIMOTHYOBRIEN ATTACHMENT DETAILS (E)COMP SHINGLE PROJECT# 9W2 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING MAX.CONTINUOUS OUTPUT 1.21A @ 240V pF NElN y �,r,P OpE MqN/R9 O'p'� 26.62 X 1.25 = 33.28AMPS 40A BREAKER-OK ACCOUNT NO : 9887503305 �* Q D LU METER NO: 98303037 y�((� 099128 (E)UTILITY METER v CTRIGP� (E)200A RATED ARQ�SMAIN SS�QNP�. (N)ENPHASE 1PHECE 20//I 40V60HZ STAMPED 04/04/2024 COMBINER BOX MODEL NO#X2-IQ-AMI-240-4 (E)200A/2P MAIN BREAKER (TOP FED) CELL WIRE LESS THESE DRAWINGS ARE SUBJECT TO MODEM COMMS COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR IQ GATEWAY WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (11)IQBPLUS-72-2-US 2-Q cable(AWG#12,SKU:Q-12-RAW-300,THHN) /� MICROINVERTERS 1-#8 AWG,BARE COPPER GROUND N)15A/ Current BRANCH-1I I ®P.11e�dI abuts 11 CANADIAN II��- iC N SOLAR:CS6R-400MS-HL T I I Engineering --- (N)20 16 (11)IQBPLUS-72-2-US I I I (N)40A/2P PV MICROINVERTERS ( J(N�)20�A�j I I BREAKER CURRENT RENEWABLES I I TO UTILITY ENGINEERING INC. BRANCH-2 I I OVERHEAD 1760 RIVERSICHICAGDE EC SUITE 11 CANADIAN I PHONE: R:(951)DE-1733 7 -- I----------------- ----------------------� FEED PHONE:(951)405-1733 N --- ------ -------- WWW.CRENG.CO SOLAR:CS6R-40OMS-HL T r I J I CONTRACTORINFO 3-#8 AWG,THWN-2 1-#8 EGC,THWN-2 IN 3/4"OR LARGER PVC CONDUIT - amll (E)GROUNDING ELECTRODE -CONDUCTOR#6 BARE COPPER CZ SYS5 ELEMENT ENERGY LLC. MODULE MANUFACTURER CANADIAN 7470 SO ND AVENUE,MATTITUCK, SOLAR NEW YORK,11952 MODULE MODEL CS6R-40OMS HL PH:(631)779 7993 services@e2sys.com MODULE(W) 400 Licence-ME-52689 MODULE PTC(W) 376.70 (MASTER ELECTRICIAN) Licence-HI-67461 MODULE Isc(A) 13.85 NOTE: (SUFFOLK HOME IMPROVEMENT) MODULE Voc(V) 36.80 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual MODULE Imp(A) 12.99 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH MODULE Vmp(V) 30.80 PROPER JUNCTION BOX AT EACH END PER 690.31A Permit Package TIMOTHY OBRIEN WIRE SCHEDULE STARTING ADJUSTMENT MAXIMUM 8.800KW Grid Tied STARTING TEMPERATURE AWG CURRENT FACTOR FOR ADJUSTED CURRENT Photovoltaic System RACEWAY CONDUCTOR ALLOWABLE TEMPERATURE CORRECTION MORE THAN 3 CONDUCTOR APPLIED TO EQUIPMENT WIRE LOCATION WIRE APPLIED TO FACTOR ## QTY. AMPACITY RATING (°C) SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 1130 SALTAIRE WAY, 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date A INITIAL DESIGN 4/4/2024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.31 0.96 1 28.80 16.64 3 AC COMBINER TO POI EXTERIOR WALL 3 8 55 90° 26.62 0.96 1 52.80 33.28 OPPORTUNITY TIMOTHY OBRIEN PROJECT# 9002 DATEDRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-4.0 TITLE ELECTRICAL 3LD BACKFEED FUSE SIZING MAX.CONTINUOUS OUTPUT 1.21A @ 240V OF NE(N�P,��O�MANS y0� 26.62 X 1.25 = 33.28AMPS 40A BREAKER-OK * ° ACCOUNT NO : 9887503305 v w m 099128 METER NO: 98303037 (E)UTILITY METER CTRtGP� (E)200A RATED A�POFESS�QNP�' (N)ENPHASE MAIN SERVICE PANEL COMBINER BOX MODEL 1 PH.120/240V 60HZ STAMPED 04/04/2024 NO#X2-IQ-AMI-240-4 (E)200A/2P MAIN BREAKER (TOP FED) CELL WIRE LESS THESE DRAWINGS ARE SUBJECT TO MODEM COMMS COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR IQ GATEWAY WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (11)IQBPLUS-72-2-US 2-Q cable(AWG#12,SKU:Q-12-RAW-300,THHN) • • MICROINVERTERS 1-#8 AWG,BARE COPPER GROUND N)15A�m• • BRANCH-1 : Current y 11 CANADIAN N ��� •�• #`iSenewa },,�t� SOLAR:CS6R-40OMS-HL (N)20;� Engineering (11)IQBPLUS-72-2-US •�• MICROINVERTERS (N)20:/-\ (N)2 A 2P PR • CURRENT RENEWABLES TO UTILITY ENGINEERING INC. AVE SUITE BRANCH-2 OVERHEAD J'3,R VIERS DE CA 92507 11 CANADIAN N FEED PHONE:(951)-405-1733 SOLAR:CS6R-400MS-HL • WWW.CRENG.CO CONTRACTORINFO 3-#8 AWG,THWN-2 1-#8 EGC,THWN-2 IN 3/4"OR LARGER PVC CONDUIT dwr (E)GROUNDING ELECTRODE CONDUCTOR #6 BARE COPPER E2SYS9 MODULE MANUFACTURER CANADIAN ELEME7470 SOUND NAV AVENUE,GY LLC. SOLAR E,MATTITUCK, C56R 400M5 NEW YORK,11952 MODULE MODEL HL PH:(631)779 7993 services@e2sys.com MODULE(W) 400 Licence-ME-52689 MODULE PTC(W) 376.70 (MASTER ELECTRICIAN) MODULE Isc(A) 13.85 NOTE: Licence-HI-67461 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS (SUFFOLK HOME IMPROVEMENT) MODULE Voc(V) 36.80 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual MODULE Imp(A) 12.99 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH MODULE Vmp(V) 30.80 - PROPER JUNCTION BOX AT EACH END PER 690.31A Permit Package TIMOTHY OBRIEN WIRE SCHEDULE STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM 8.800KW Grid Tied RACEWAY CONDUCTOR AWG ALLOWABLE TEMPERATURE CORRECTION CURRENT FACTOR FOR ADJUSTED CURRENT Photovoltaic System # EQUIPMENT WIRE LOCATION QTY. AMPACITY RATING (°C)WIRE APPLIED TO FACTOR MORE THAN 3 CONDUCTOR APPLIED TO SIZE CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 1130 SALTAIRE WAY, 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY MATTITUCK,NY 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description I Date A INITIAL DESIGN 4/4/2024 2 AC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 13.31 0.96 1 28.80 16.64 3 AC COMBINER TO POI EXTERIOR WALL 3 8 55 90° 26.62 0.96 1 52.80 33.28 OPPORTUNITY TIMOTHYOBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-5.0 TITLE ELECTRICAL SLID MATERIAL LIST CAP DBE MA/yjR �'p� ELECTRICAL EQUIPMENTS C: 2 D W QTY. PART TYPE PART NUMBER DESCRIPTION 2 °N128 22 MODULE CS6R-40OMS-HL CANADIAN SOLAR CS6R-400MS-HL CT 22 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US AR��SSI�NP� 1 COMBINER X2-1Q-AM1-240-4 ENP HAS E COMBINER BOX X2-IQ-AM1-240-4 STAMPED 04104I2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 W WW.CRENG.CO CONTRACTORINFO BREAKER / FUSES QTY. PART TYPE PART NUMBER DESCRIPTION 1 FUSES 40A FUSES GENERAL 40A FUSES a IN 01 2 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) E2 YS5 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 - PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) RACKING Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 12 RAILS & SPLICES XR-100-168B XR100, RAIL 168" BLACK- Permit Package 8 RAILS &SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 TIMOTHYOBRIEN 48 CLAMPS & GROUNDING UFO=CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK 8 CLAMPS & GROUNDING UFO-STP-35MM-B1 _ STOPPER SLEEVE, 35MM, BLACK lt Grid Tied 2 CLAMPS & GROUNDING XR-LUG-03-A1 GROUNDING LUG, LOW PROFILE Phhotovotov oltaic System 44 ATTACHMENTS QM-HUG-01-B1 HALO ULTRAGRIP, BLACK 1130 SALTAIRE WAY, MATTITUCK,NY 11952 88 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.OL Rev Description Date 44 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE A INITIAL DESIGN 4/4/2024 OPPORTUNITY TIMOTHYOBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN SY E.R SHEET# PV-6.0 TITLE BOM EXISTING SERVICE PANEL PHOTOS OF NEW- ��P o�E MA/yjR �'p� r W 11! 099128 Z { CTRIrG ARo�Ss�oNP� STAMPED 04/04/2024 tti THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewables - Engineering CURRENT RENEWABLES AL ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 W W W.CRENG.CO CONTRACTORINFO MEN CZSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 pi ll °T PH:(631)779 7993 services@e2sys.com Licence-ME-526B9 4111 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual + Permit Package 1; TIMOTHY OBRIEN 1 - I 8.800KW Grid Tied -" -j Photovoltaic System .. I ,:-� �, •, ;_. 1130 SALTAIRE WAY, MATTITUCK,NY 11952 r- Rev Description I Date •' A ' ,�, A INITIALDESIGN 1 4/4/2024 ram• OPPORTUNITY TIMOTHY OBRIEN _I PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-7.0 TITLE ELECTRICAL PHOTOS OF NEPV AS" O-E MAIVjR G'P� _ r D W PHOTOVOLTAIC m 099128 Z EQUIPPEDD• 4 CT ticu ARo�s 31oNP� 690.12 STAMPED 04/04/2024 I THESE DRAWINGS ARE SUBJECT TO L — COPYRIGHT PROTECTION BY US LAW. TURN RAPIDM IS , • EXPREESS YTION ORBIDD N WIN ANY ITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT SHUTDOWN SWITCH TO RATED ' OUTPUT CURRENT 26.62 AMPS RENEWABLES ENGINEERING INC. THE "OFF" POSITION TO AC — AC NORMAL OPERATING VOLTAGELVOLTS SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Current AND REDUCE SHOCK _ Reewabl�s HAZARD IN THE ARRAY Engineering 690.56(C)(1)(B) P M DUAL POWER SOURCE8 CURRENT SEC• , SOURCE R PHOTO- • • VOLT,IC SYSTEM ENGWEERINGINCABLES RATED ' , . OUTPUT . CURRENT ■ • • AMPS . 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)d05-1733 r AC NORMAL ■ , OPERATING . . , VOLTAGE. , 40 VOLTS WWW.CRENG.CO CONTRACTORINFO 690.54 — — OPTIONAL SOLAR LOAD CENTER ARRAY "— E2SYSA ELEMENT ENERGY LLC. J/B 7470 SOUNDENUE19MZTTITUCK, NEW O PH:(631)779 7993 . services@e2sys.com lwv� L _ Licence-ME-52689 (MASTER ELECTRICIAN) INVERTER OUTPUT CONNECTIONI Licence-HI-67461 • • RELOCATE (SUFFOLK HOME IMPROVEMENT) NEC 690.31(G)(3)&(4),CRC R324.7 Solar Individual Permit Package (UNLESS.BUSBAR IS FULLY RATED) L — 705.12(D)(2) PHOTOVOLTAIC POWER SOURCE TIMOTHY OBRIEN ---------- -- -- - - EVERY 10'ON CONDUIT AND ENCLOSURES 8.80OKW Grid Tied Photovoltaic System NOTES. 1130 SALTAIRE WAY, MATTITUCK,NY 11952 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS Rev Desviption Date SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A INITIAL DESIGN ararzoza A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE OPPORTUNITY TIMOTHYOBRIEN WORK. PROJECT# 9002 DATE DRAWN 4r412024 C. AERIAL FONT. DRAWN BY E.R 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN SHEET# PV_8.0, THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE TITLE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. Of NEW)- ��Q` O MA/V�Q O�0 4 D w 2 099128 _ lP� C7RICP� ARo�Ss�oNP� STAMPED 04/04/2024 CAUTION ' REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. PV ARRAY Current- Renewabte5 Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 - PHONE:(951)-405-1733 Q W W W.CRENG.CO CONTRACTORINFO Uj IY Ln J CPSYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 i services@e2sys.com MAIN SERVICE PANEL Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 i COMBINER (SUFFOLK HOME IMPROVEMENT) i UTILITY METER Solar Individual A Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL TIMOTHYOBRiEN PANEL JS-AC-DISCONNECT PER NEC690.17 8.800KW Grid Tied Photovoltaic System 1130 SALTAIRE WAY, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 4/4/2024 OPPORTUNITY TIMOTHYOBRIEN PROJECT# 9002 DATE DRAWN 4/412024 DRAWN BY E.R SHEET# PV-6.1 TITLE PLACARD MICROINVERTER CHART 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 C UM 1 MSP 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 Current Renewables Engineering CURRENT RENEWABLES 4 ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 W W W.CRENG.CO CONTRACTORINFO 5 CZSYS ELEMENT ENERGY LLC. 6 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-526B9 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package TIMOTHY OBRIEN - --- — — 8.800KW Grid Tied 8 Photovoltaic System 1130 SALTAIRE WAY, MATTITUCK,NY 11952 _Rev Description Dale A INITIAL DESIGN 4/4/2024 9 OPPORTUNITY TIMOTHYOBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-9.0 10 TITLE MICROINVERTER CHART SAFETY PLAN C UM MARK UP KEY MSP INSTRUCTIONS: COMBINER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET. EXPRESSLY FORBIDDEN WITHOUT PRIOR 2.SAFETY PLAN MUST BE MARKED BEFORE JOB MSP MAIN SERVICE PANEL WRITTEN APPROVAL FROM CURRENT .STARTS AS PART OF THE PRE-PLAN RENEWABLES ENGINEERING INC. 3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE M UTILITY METER &MAKE NOTES ON THE JHA SHEET IN CASE OF EMERGENCY © PERMANENT ANCHOR Renewable JB JUNCTION BOX Engineering, NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC O TEMPORARY ANCHOR CURRENT RENEWABLES NAME: ENGINEERING INC. ADDRESS: IL INSTALLER LADDER 1760 CHICAGO AVE RIVERSIDE RIV(95��� 3317E J ERSIDE CA 8250E P STUB-OUT WWW.CRENG.CO SAFETY COACH CONTACT INFORMATION CONTRACTOR INFO NAME: ® SKYLIGHT ADDRESS: 0 a ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE ❑ NO c=A�DI DT �A���'V'CS STEEP GRADE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE " CJt�'C51-tC JA9 %STRUCTIONS) EPSYSI AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR CONDUIT WORKING SAFELY. ELEMENT ENERGY LLC. GAS GAS SHUT OFF 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 NAME SIGNATURE 20" WATER SHUT OFF PH:(631)779 7993 services@e2sys.com Licence-ME-52689 7O SERVICE DROP (MASTER ELECTRICIAN) Licence-HI-67461 OPOWER LINES (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package TIMOTHY OBRIEN - - 8.800KW Grid Tied Photovoltaic System 1130 SALTAIRE WAY, MATTITLICK,NY 11952 Rev DesOnptiOn Date A INITIAL DESIGN 4/4/2024 DATE: TIME: OPPORTUNITY TIMOTHYOBRIEN PROJECT# e002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-10.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel,and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. The safety of the Client and the Public must be maintained at all • The site supervisor shall forecast the weather conditions at the • Employees shall have access to restroom facilities with Extension ladders must be set up on a firm and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations.Use of onsite restroom is at the clients a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below).If client does not give THESE DRAWINGS ARE SUBJECT TO COPYRIGHT BY US secured to the structure.Extension style ladders placed on work zone through the use of barriers and/or signage,as • The site supervisor will utilized a portable wind meter permission,location of suitable restroom facilities with REPRODUCTION INEANYO FORM SLAW uneven,loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. • Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at any point. RENEWABLES ENGINEERING INC. the ladder must extend 36"above the stepping off point. • Pets(including dogs)shall be secured by their owners prior to staging on a roof. Restroom facilities will be circle one):Onsite-Offsite • A-frame ladders must only be climbed with the ladder spreader work start. • Elevated work involving the moving or maneuvering of solar • If Offsite,add location name and address: bars locked in the open position;A-frame ladders shall not be • The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind 11 Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting ProcedureCyn�.y�/s58I�61� leaned a ainst a structure). Workers. Forecasted weather maximum temp(degrees F): • Contact your Site Supervisor • Additional notes: Crew leader responsible for communication with the client: Engineering Name: Mobile Equipment • Client and public is excluded from work area by barricades(N/A, • OnlyQualified operators will operate equipment;o erators must Yes,No: Heat Related Illness Prevention Phone: CURRENT R G INC. LES P PP ) ENGINEERING INC. maintain a certification on their person for the equipment being • Employees shall have access to potable drinking water that is 1760 CHICAGO AVE SUITE operated. Training and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13,RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): • All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE:(951)-405-1733 WWW.CRENG.00 hazards of this project and review this HJA during a pre job Water shall be supplied in sufficient quantity at the beginning of Name: • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift.Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor hazard to client,personnel or public.Materials stored on the • Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically protect from failing or sliding off. 1 1 frequent drinking of water shall be encouraged. Name: ® !"" • Crew member(name/title): Shade shall be present when temperature exceeds 80 degrees � ��/�� Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone: T v- • A site-specific plan for fall prevention and protection is required Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until I or more areas with shade at all times. With:Your full name,phone number,office location,brief description work is complete;a fall rescue plan must be outlined and • Crew member(name/title): New employees must be acclimatized.New employees will be of what happen and when. ELEMENT ENERGY LLC. discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two 7470 SOUND AVENUE,MATTITUCK, NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE NEW Y 9 52 • First-person-Up(FPU)must install their anchor and connect • Crew member(name/title): (2)weeks of employment or longer when necessary. PH:(631)1)779 779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roof • Crew member(name/title): scheduled breaks during each shift. Employees must take Licence-ME-52689 uninstalling fall protection. cool-down breaks in the shade any time they feel the-need to do (MASTER ELECTRICIAN) • FPCP(name and title): Airbome Contaminants: so to protect them from overheating.Supervisors are Licence-HI-67461 • Asbestos-containing(Transite)piping(ACP)-Do not disturb REQUIRED to allow employees any break period they need Define the Hazard: Method/steps to prevent incident: (SUFFOLK HOME IMPROVEMENT) FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and • Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. • All electrical work will be performed with equipment in an TIMOTHY OBRIEN electrically safe condition(de-energized)unless approval has • If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. ------- --- -,-all employees on-site? 8.800KW Grid Tied • Service drops and overhead electrical hazards will be • If offsite replenish is necessary,where will you go to replenish indentified and protected from contact as neccessa . water(location/address): Define the Hazard: Method/steps to prevent incident: Photovoltaic System EQP(name and tile): • Who will replenish the drinking water(name): 1130 SALTAI RE WAY, MATTITUCK,NY 11952 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIALDESIGN 4/4/2024 OPPORTUNITY TIMOTHYOBRIEN PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-11.0 TITLE SAFETY PLAN \,f: C�IIa�Ia11SVh1 ENGINEERING DRAWING(mm) CS6R400MSHL/I-VCURVES f A A Rear View Frame Cross Section - -- - to�- ------ia A-A 13 x, r 2 rP--"_-- 1 12 35 11 _ __- THESE DRAWINGS ARE SUBJECT TO a COPYRIGHT PROTECTION BY US LAW. ,f 7 REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR s P/RITTEN APPROVAL FROM CURRENT e _ a RENEWABLES ENGINEERING INC. -- - Mounting Hole z - 2 • - - I` ;�,� 5 10 15 20 25 3O 35 40 45 50 55 60 5 10 15 20 25 30 35 40 45 50 55 60 V Current -r* ■ iwowm� sc■ ales r$-"---' ~ -t�� ■ BOO w/m' 25c■ H'Ku6 (All-Black) _a5 --1 -9 M 4Ww� 45•C -6 Engineering ALL BLACK MONO PERC ■ �w/W CURRENTRENEWABLES ENGINEERING INC. ELECTRICAL DATA I STC* MECHANICAL DATA 1160 CHICAGO AVE SUITE 380 W--405 W CS6R-380/385/390/395/400/405MS-HL Specification Data J-13,RIVERSIDE CA 92507 - PHONE:(951)-405-1733 CS6R-380 1 385 1 390 1 395 1 400 1 405MS-HL Nominal Max.Power(Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type Mono-crystalline WWW.CRENG.CO Opt Operating Voltage(Vmp)30.0 V 30.2 V 30.4 V 30.6 V 30.8 V 31.0 V Cell Arrangement 108[2 X(9 X 6)] CONTRACTOR INFO Opt Operating Current(Imp)12.69 A 12.77 A 12.84 A 12.91 A 12.99 A 13.07 A Dimensions 1722 x 1134 x 35 mm , Indu Leadin Product Warrantyon Materials Open Circuit Voltage(Voc) 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V (67.8 x 44.6 x 1.38 in) MORE POWER 25 - sm 9 Years � and Workmanship* Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 22.4 kg(49.41bs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 mm tempered glass with anti-ref Module power up to 405 W lective coating EM �••� 405 Uy Operating Temperature -40•C-+85`C Frame Anodized aluminium alloy, Module efficiency up to 20.7% 25 : Linear Power Performance Warranty* Max System Voltage 1000V([UL 61) J-Box IP68,3 bypass diodes l_2 SYS� Years TYPE 2(UL 617301000V) Module Fire Performance or CLASS C(IEC 61730) Cable 4 mm2(IEC),12 AWG(UL) Lower LCOE&system cost 1i'T year power degradation no more than 2% Max Series Fuse Rating 25 A Connector T6,MC4,MC4-EV02 or MC4-EVO2A ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, Subsequent annual power degradation no more than OSS% Application Classification Class A Cable Length + in)(-)* NEW YORK,11952 Connector) 1550 mm(61.0 in)()/1100 mm(433 *Subject to the terms and conditions conta'ored in the applicable Canadian Solar Umited Power Tolerance 0-+IOW (Including PH:(631)7797993 Warranty Statement Also this 2Syear fimited product warranty is available onlyfor prod- ComprehensiveLID/LeTIDmitigation uc6lnstalledando operating an residential incertainre ions Per Pallet 30 pieces services@e2sys.com p 9 Ps 9 *Under standard Test irradiance of w/m',spectrum/Ud lS and cell temps- Licence-ME-52689 technology,u to 50%lower degradation _._............___..__................................_......__.._..--_-._.__..._-.._.__...._.._.._._..-_... raWreof25-C P 9 Per Container(40'HQ)780 pieces (MASTER EL ECTRICAN) MANAGEMENT SYSTEM CERTIFICATES* *For detailed information,please contact your local Canadian Solar sales and Licence-ECTRI I ISO9001:2015/Qualitymanagementsystem technical representatives. (SUFFOLK HOME IMPROVEMENT) Better shading tolerance ISO 14001:2015/Standards for environmental management system L3 150 45001:2018/International standards for Occupational health&safety ELECTRICAL DATA I NMOT* Solar Individual TEMPERATURE CHARACTERISTICS PRODUCT CERTIFICATES* C56R380/385/390/395/400/405MS-HL Permit Package MORE RELIABLE IEC 61215/IEC 61730/CE Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Data CEC listed(US California)/FSEC(US Florida) Opt.Operating Voltage(Vmp)28.1 V 28.3 V 28.4 V 28.6 V 28.8 V 29.0 V Temperature Coefficient(Pmax) -0.34%/°C TIMOTHY O B R I EN Ta e-e-w/IEC 69701/IEC 62796 Temperature Coefficient OC -0.26%/°C rake-e-way Opt Operating Current(Imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A P (V ) Minimizes micro-crack impacts P+ Open Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34.4 V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/•C �E sA ( E = g P 8.800KW Grid Tied @ '= c us Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A Nominal Module Operating Temperature 42 t 31C Photovoltaic System *The specific certificates applicable to different module types and markets will vary, *Under Nominal Module operating Temperature(NMOT),irradiance of 800 W/rrF-spectrum AM 1.5, * Heavy snow load up to 8100 Pa, and therefore not all ofthe certifications listed herein will simultaneously apply to the ambient temperature 20°c,wind speed l m/s. products you order or use.Please contact your local Canadian solar sates representative PARTNER SECTION I= Wind load up to 5000 Pa* to confirm the specfic certificates available for your Product and applicable in the regions .................................................................................................................. 1130 SALTA]RE WAY, in which the products will beused. MATTITUCK,NY 11952 •--".........................................................•--...................................._..........._............_. CSI SOLAR(USA)CO.,LTD.i5 committed to providing high quality Rev Description Date solar photovoltaic modules,solar energy and battery storage solutions to 4 INITIAL DESIGN 4/4/2024 customers.The company was recognized as the No.1 module supplier for The specifications and key features contained In di Is dataSheet may deviate slightly from our actual qualityand performance/price ratio in the IHS Module Customer Insight products due to the ongoing innovation and product enhancement CSI Solar Co.,Ltd.reserves the right to make necessary adjustment to the information described herein at any time without further Survey.Overthe past 20 years,it has successfully delivered over 70 GW notice. OPPORTUNITY TIMOTHY OBRIEN *For detailed information,please refer to the Installation Manual. Of premium-quality solar modules across the WOrid Please be kindly advised that PV modules should be handled and Installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using PROJECT# 9002 .................................................................................................................................................................................................................................................................. our PV modules. . :..................................._......................................_.....................................� DATE DRAWN 4/4/2024 CSISOLAR(USA)CO.,LTD. ......................................................................................._.............................................................................................................................................................................. DRAWN BY E.R 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94598,USA I www.csisolar.com/na I service.ca@csisolar.com CSI SOLAR(USA)CO.,LTD. Aug 2022 1 All rights reserved I PV Module Product Datasheet v1.1 C25_F23J1_NA SHEET# PV-12.0 TITLE MODULE SPEC v ENPHASE. ® IQ8 and IQ8+ Microinverters - _v___ _ - - - - - - --•- - - ----------- --- - --- -- -- - - - - Commonly used module pairings' - - _W - - 235-350- - - - - - - _ 235-440 - - - - I Module compatibility _ To meet compatibility,PV modules must be within maximum Input DC voltage and maximum module 1.listed below. Module compatibility can be checked at httpsl/enphase-com/installers/microimerters/calculator FMPPT voltage range V .27-37 _ ---` - 27-45•' T THESE DRAWINGS ARE SUBJECT TO - _ - V 18-48 16-58 Operating range I - _ - - COPYRIGHT PROTECTION BY US LAW. - _ - _ REPRODUCTION IN ANY FORM IS Minimum/Maximum start voltage' V _ - -22/48 t - _ 22/58 - - _- -- EXPRESSLY FORBIDDEN WITHOUT PRI OR Maximum input DC voltage i V 50 [ 60 WRITTEN APPROVAL FROM CURRENT ------------------- - --------- --- - _ - - _-- - ---------- -- ------- RENEWABLES ENGINEERING INC. ;'Maximuin continuous-input DCcurrent. A : • - - : - 10: - _ : _ - _ : - : _ 12 Maximum input DC short-cireuitcurrem I A i 25 - •. a - i,Maximum module 1;_ _. _ - - A - - - - - _ _ - : - 20 Current _ - Overvoltage class DC port - I II - e DC port backfeedcurrent: - - - - :mA - _0� aa13e•9� ��Y .. ___' Engineering. PV array configuration { — 41=1 ungrounded array,no additional DC side protection required;AC side protection requires maximum 20 A per branch circuit. L / CURRENT RENEWABLES Peak output power VA 245 300 ENGINEERING INC. _ - - - - - 1760 CHICAGO AVE SUITE Maximum continuous output power VA I 240 ! 290 J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 i Nominal grid votage(L ) 'V 240;sp1rt-pfiase(L L),180'" - WWW.CRENG.CO IQ8and IQ8+ Microinverters Easytoinstall : Minimum and Maximum gridvoltaget j v 211-264 CONTRACTOR INFO + Lightweight and compact with plug- Maedmtmi continuous output current =A - - - `1A Our newest I08 Microinverters are the industry's first mierogri i forming,software-defined and-play qnnnemcto icati0 . mail frequency — I Hz I — microinverters with split-phase ower conversion capability Nominal - - - -- 60 - -- -- - _ -P pabiGty to convert l�power to AC power efficient) The brain of the semiconductor-based microinverter is ourproprietaryPo. er Gn m n(PLC) : Extended he ue�- : 47-68" Po Y- -between coin onents q nay range Hz: application-specific integrated circuit(ASIC),which enables the microirrverterto operate inACstiort-I-' _ p — 9 09 Pe Po n9 n9 9 9 g three cycle rcu t faukcu ---— grid-tied or off-grid modes_This chi is built usin advanced 55-nm tech with high-speed Arms{ 2 rremover k 9 KJ P9 technology 9 P� Faster installation with simple two wire . ( ! C �Y � es digital is and has superfast response times to cha i loads and rid events,alleviating oablin --- -----_ --- ---• ---- -- --- - --- - -- —..--- - - ---- - constraints on battery sizing for home energy systems. Maximuim units per20 A(L-L)brahch ^, _ : _ - 'circuit` - 1f3 - _ - - .13 - i High prodtrctiliityrnd reliability I Total harmonic distortion ENERGY LLC Produce.power even when_thegridis. . _ _ %- N 1 , _ _ - "- -- 7470 SOUNDAV AVENUE,MATTITUCK, <5 i : down': - • OvendoltageclassACport NEW YORK,11952 Enphase - - More than one million cumulative hours AC p art backfeed curem mA i 30 H:(631)779 7993 ��^ P jof testing. - - - ,' _ � - - ---- - _ - - - - - � _ - _ ..-- -. --------- --_------ ---- ------ services@e2sys.com Power factor setting - to- Licence-M E-526 B9 j_ _•.Classlldouble-insulatedenclosure - I oa5leadin o.851a m Grid-tied powerfactor(ad)urstable) - i g- lagging (MASTER ELECTRICIAN) Part of the Enphase Energy System, I08 Series Microirrverters redefine Optimized for:the latest high:powered : I : Licence-HI-67461 I08 Series Microinverters integrate with the reliability standards with more than one i. PV modules- Peak efficiency % _ 9Z7.' g y (SUFFOLK HOME IMPROVEMENT) IQ Battery,IQ Gateway,and the million cumulative hours oFpower-on _ CEC weighted efficiency ; 97 Enphase App monitoring and analysis testing,enabling an industry-leading - --------- - -------AL! -- - .-- --"- -- _-- -- - -- -'--- -- Solar Individual Micro till software. lim-itedwarranty ofupto25years. I - . g.- 9 _ : Nighttimepower,consumption" : _ -mW- 23 - - _ - - 25~ _ - - Compliantwiththelatestadvanced," - Permit Package " -grid support" Port•• mperature range - - - - - 60'C(-401F to 140•F) " . - . _ Reinoteautomaticupdatesf TIMOTHY OBRIEN updates-for - - : 'latest grid requirements - - - :-. Relative 4 ti ehumid-ityrange - - - i 4%to 100%(condensing) Configurable tosupporta wide ranget:------ - --- - i DCccnnecter.type _ MC4 $.$OOKW Grid Tied of grid profiles : Dimensions(H=W•D) 1 212 min(83 in)=175 mm(6.9 in)=302 mm(1.2 In) Photovoltaic System i Meet CA Rule 21(UL 1741,SA)and IEEE - '' - - ' Connect PV modules quickly and easily IOS Series Microinverters are UL Listed - -weight 08 kg(2.38lbs) to I08 Series Microinverters using the as PV rapid shutdown equipment and 1547.-2018(UL 174t-SB31d Ed.): : — Cooling Natural convection-no fans 1130 SALTAIRE WAY included Q-DCC-2 adapter cable with conform with various regulations,when _ _ _ _ plug-and-play MC4 connectors. installed according to the manufacturer's 4: e - _. : MATTITU CK,NY 11952 instructions. "NOTE: i"APProvedforwetlxatioris" _ - - Yes _ - 168Microimrerterscannotbemixedwith -� — _ Pollution degree PD3 Rev Description Dale - Previous generations of Enphaserniicrdnverters _ _ _ i :OO7Ss6s%lo6sefes,andsoon)inthe same Enclosure - - - : - - - Class ll double-insulated,corrosion-resistant polymeric enclosure : A INITIAL DESIGN 4/4I2024 - ( lO Gatewayisiequired to charge'thede(auit - Environmental category/UV exposure rating i NEMA Type 6/Outdoor •Meets UL 1741 only when Installed with lO System Controller 2 I- -grid profile at thetim m e of lnstallat1w to eet. ••108 and 108+support split-phase,240 V Installations only. i bcal Authorfty}faving Jurisdiction.(AHJ) OPPORTUNITY TIMOTHYOBRIEN I requhereents,- - - j (gNo.nrecmoc/Acrnw PROJECT# 9002 CO-- 0 Enphase Energy.All rights reserved Enphass,the a and CC logos,l0.and certain other marks fisted at ' _ - _ - - - ryq,,,o=d,prtaye,e„a,�b,,t—leduermd aarntrr.IBmw,aea bythe WHO. httpr//ens)hwe=m/trademark-usage-guidelines are trademarks of Enphase Energy,Inc.in the US and other countries.Data subject to change.•--- --- Ip85p-VA-DSH-00207-20-EN-US-2023-10-13 (s)taMa meyvary.aerermWmregwem.mcmaePoremamvnbw or mivcimiartw.prbnrchmyour uea 10aSP-12A-DSH-00207-20-EN-US-2023-10-13 DATE DRAWN 41412024 DRAWN BY E.R SHEET# PV-12.1 TITLE MICROINVERTER SPEC IQ Combiner 4/4C Data Sheet Enphase Networking MODEL NUMBER f IQ Combiner 4 IQ Combiner 4with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C1220±0.5%) �XAQ-AM7-240-4 and consumption monitoring(t 2.5%).Includes a silver solar shield to match the IQ Battery and fQ System Controller 2 and to JJ X2-10-AM1-240-4(IEEE 1547:2018) deflect heat. IQ Combiner 4C -IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0.5%)' 0 ®Il1bl11�C �/�C The t Combiner 414C with IQ Gateway and X-I0-AM7-240-4C and consumption monitoring(±2.5%).Includes Mobile Connect cellular modem(CELLMODEM-MI-06-SP-05),a plug-and-play Q Q y X2-IQ-AM7-240-4C(IEEE 1547.2018) industrial-grade cell modem for systems up to 60 microimerters.(Available in the US,Canada,Mexico,Puerto Rico,and the THESE DRAWINGS ARE SUBJECT A ���CCC US Virgin Islands,where there is adequate cellular service in the installation area.)Includes a silver solar shield to match the REPRODUTIONINANYFOR PROTECTION IS LAW. integrated LTE-M1 .cell modem(included IQ Battery and IQ System Controller and to deflect heat. EXPRESSLY FORM EXPRESSLY FORBIDDEN WITHOUT PRIOR ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) WRITTEN APPROVAL FROM CURRENT only with IQ Combiner 4C)consolidates Supported microinverters - IQ6,IQ7,and IQ8.(Do not mix IQ6/7 Microinverters with I08) - RENEWABLES ENGINEERING INC. interconnection equipment into a single -- --- ------- ----------- - —� Communications Kit enclosure. It streamlines IQ Microinverters and COMMS-CELLMODEM-Ml-06 Includes COMMS-KIT-01 and CELLMODEM-MI-06-SP-05 with 5-year Sprint data plan CELLMODEM-M7-06-SP-05 4G based LTE-Ml cellular modem with 5-year Sprits data plan Current CELLM_ODEM-MI-06-AT-05 -4G based LTE-M1 cellular modem with 5-year AT&T data plan Renewable � � Q storage installations by providing a consistent, �- _ _ _ ss Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. µ.i pre-wired solution for residential applications. RK_ ` Engineering Q r� 3ENPHASE ; _BRK-10A-2-24DV Circuit breaker,2 pole,IOA,Eaton BR215 - Engineeri1 g BRK-1 SA 2-240V Circuit breaker,2 pole,15A,Eaton BR215 i y l £ It offers up to four 2-pole input circuits and i BRK20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-240V-8 Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support Circuit breaker,2 Ole,20A,Eaton BR2208 with hold down kit support CURRENT RENEWABLES } Eaton BR series bUSbar assembly. t BRK20A-20A -24DV-8 pole, PP`_ ENGINEERING INC. n XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C — _ 1'r60 CHICAGO AVE SUITE Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) J 13,RIVERSIDE CA 92507 P10NE:(951)-405-1733 X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws VMIW.CRENG.CO }Consumption monitoring CT- A pair of200A,split core current transformers - - CONTRACTORINFO - I Smart (CT-200-SPLITICT-200-CLAMP) t ELECTRICAL SPECIFICATIONS °' • Includes IQ Gateway for communication and control f �I p )Rating Continuous duty- - Includes Mobile Connect cellular modem T t�l (CELLMODEM-M7-06-SP-05),included only with System voltage ~ 120/240VAC,60 Hz 1 F atop SR series busWr rating 125A ° IQ Combiner 4C SYS� • Includes solar shield to match Enphase IQ Battery Max.continuous current rating 65A T u r aesthetics and deflect heat fMax continuous current rating(input from PV/storage)�64A • Supports wi-Fi,Ethernet,or cellular connectivity Max.fuse/circuit rating(output) 9oA ELEMENT ENERGY LLC. Optional AC receptacle available for PLC bridge Branch circuits(solar and/orstorage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) l 7470 SOUND AVENUE,MATTITUCK, - Provides production metering and consumption r— NEW YORK,11952 P g P Max.total branch circuit breaker rating(input) BDA of distributed generation/95A with IQ Gateway breaker included PH:(631)779 7993 monitoring IQ Gateway breaker - 10A or 15A rating GE/Siemens/Eaton included � � _ services@e2sys.com 1( Production metering CT w 200A solid core pre-installed and wired to IQ Gateway _ Licence-M E-52689 Zi Simple MECHANICAL DATA (MASTER ELECTRICIAN) Licence-HI-67461 X-IQ AM7 240.4C • Mounts on Single Stud wih Centered brackets I Dimensions(WxHxD) -�� 37-5 cm x 49.5 cm x 16.8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mounting brackets. (SUFFOLK HOME IMPROVEMENT) t X21Q-AM1240,4C(IEEE 15472 Weight 7.5 kg(16.5lbs) 018) �. - Supports bottom,back and side conduit entry Solar Individual f I i • Allows up to four 2-pole branch circuits for 240VAC mbient temperature range -aD°C to+a6°C(40°Fto T15°T) —_. _ � --.-------.---- Permit Package plug-in breakers(not included) Cooling Natural convection,plus heat shield s= • 80AtotalPVorstora storage —` _ _ _ TIMOTHY OBRIEN { 9 1 Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R;polycarbonate construction I iL_.--_._._e____._.___.__�._.._..� - - - -- Wire sizes _-- 20A to SOA breaker inputs:l4 to 4 AWG copper conductors _________ ____ ___ ___ __ 60A breaker branch input:4 to 1/0 AWG copper conductors i Reliable �- Main lug combined output:10 to 2/0 AWG copper conductors 8.800KW Grid Tied Neutral and ground:14 to 1/0 copper conductors Durable NRTL-certified NEMA type 31R enclosure Always follow local code requirements for conductor sizing. Photovoltaic System F Five-year limited warranty ;Altitude y` --Up to 3,000 meters(9,8'42 feet) ' - Two years labor reimbursement program coverage INTERNET CONNECTION OPTIONS 1130 SALTAIRE WAY, included for both the IQ Combiner SKU's MATTITU CK,NY 11952 Integrated Wi-Fl IEEE 802.11b/g/n UL listed t— XIQAM12404 '"' Cellular CELLMODEM-M7-06-SP-05,CELLMODEM-M1-06-AT05(4G based LTE-Mlcellularmodem).Note that an Mobile Connect R ev Description Date • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with cellular modem is required for all Enphase Energy System installations. A INITIAL DESIGN 4i4r2024 X2-IQA UL 1741-SB,3 Ed.)1547:2018) IEEE 1547.2018 nd ( ) Ethernet Optional,IEEE 802.3,Cat5E(or Cat6)11TP Ethernet cable(not included) COMPLIANCE Compliance,IQ Combiner CA Rule 21(UL 1741-SA) I PPORTUNITY TIMOTHY OBRIEN U1 _ IEEE 1547:2018-UL 1741-SB,3"Ed,(X2-IQ-AM7-240-4 and X2-IQ-AM1-240-4C) CAN/CSA C22.2 No.107.1,Title 47 CFR,Part 15,Class B,ICES 003 9002 Production metering:ANSI C12.20 accuracy class 0.5(PV production) CATE DRAWN 41412024 Was EPIPHASE. — Consumption metering+accuracy class2.5 _� CRAWNBY E.R To learn more about Enphase offerings,visit enlohase.com �� Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 SHEET# PV-12.2 IQ-C-4-4C-DS-0103-EN-US-12-29-2022 ©2022 Enphase Energy-All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of TITLE Enphase Energy,Inc.Data subject to change. IQ-C-4-4C-DS-0103-EN-US-12-29-2022 COMBINER SPEC ®ML IRONRIDGE XR Rail° Family XR Rail°Family The XR Rail®Family offers the strength of a curved rail in three targeted sizes.Each size supports specific Solar IS Not Always Sunny - design loads,while minimizing material costs.Depending on your location,there is an XR Rail®to match. Over their lifetime,solar panels experience countless THESE DRAWINGS ARE SUBJECT TO -_ COPYRIGHT PROTECTION BY US LAW. extreme weather events-Not just the worst storms in years, _ ^"` � REPRODUCTION IN ANY FORM IS but the worst Storms In 40 years.High winds capable of EXPRESSLY FORBIDDEN WITHOUT PRIOR ripping panels from a roof,and snowfalls weighing -... WRITTEN APPROVAL FROM CURRENT��`— -- i �--------�•_ � RENEWABLES ENGINEERING INC. enough to buckle a panel frame- XR Rails@ are the structural backbone 1'preventing these results-They resist uplift, XR10 XR100 XR1000 Current 1' a abl s protect against buckling and safely XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among Engineering efficiently transfer loads into the f/�"tea rail,designed for regions with fight or mounting rail.It supports a range of solar mounting rails-It's built to handle t ;` building structure.Their no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 superior ;r _ �® while remaining light and economical. maximizing spans up to 10 feet feel for commercial applications- CURRENT RENEWABLES spanning capability requires fewer ENGINEERINGINC.S 1 6'spannin capability 10's annin capability 12' nin Ih roof attachments,reducing the g�•►v p s p w �n g capability 1760 CHICAGO AVE SUITE Y ,�vy _.`' Moderate load capability Heavy load capability Extreme load capability J-13,RIVERSIDE CA 92507 number of roof penetrations ,., ; • ti� x, d ; Clear&black anodized finish Clear&black anodized finish Clear anodized finish PHONE:(951)-4D5-1733 ..g. . and the amount of •, '. ° vwWv.cRENG.co ' .T J 1 -� tl Internal splices available Internal splices available Internal splices available installation time. _ 1 CONTRACTOR INFO Rail Selection ..., The table below was prepared in compliance with applicable engineering codes and standards.'Values are based on the following criteria:ASCE 7-16,Gable Roof Flush Mount,Roof Zones 1 &2e,Exposure B, Roof e ZSYS - �', �•�" :h�-: �� �:p; Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit IronRidge.com for detailed certification letters. E � 4 r.-, ;.' .• Rail Span ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, a... ` • • ®® � NEW YORK.11952 PH:(631)779 7993 Force-Stabilizing Curve 90 services@e2sys.com " Licence-ME-52689 Sloped roofs generate both vertical and lateral 120 I forces on mounding rails which can cause them to (MASTER ELECTRICIAN) y bend and twist The curved shape of XR ReWSO None Licence-HI-67461 140 XR10 XR700 XR1000 is s ecially designed to increase stren th to both (SUFFOLK HOME IMPROVEMENT) M directions while resisting the twisting.This unique feature ensures greater security during extreme 160 Solar Individual + *g weather and a longer system lifetime. - `< ;, y, 90 Permit Package , ., . .r '`;" �x.,>•1•� 120 TIMOTHY OBRIEN .ti 20 140 ; s 160 8.800KW Grid Tied Photovoltaic System 90 30 1130 SALTAIRE WAY, 160 i - - MATTITUCK,NY 11952 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 I Rev Description Date XR Rails®are IronRid egoffers All XR Rails®are made of 6000-sedes �� I'I A g ^.� 40 •� ��i ��''I��� A INITIAL DESIGN 41412024 compatible with o a range of tilt leg aluminum alloy,then protected with an 160 FlashFooO and options for flat anodized finish-Anodizing prevents surface ® other pitched roof roof mounting and structural corrosion,while also providing - 80 160 attachments. applications, a more attractive appearance- OPPORTUNITY TIMOTHY OBRIEN —11 120 160IBM PROJECT# eooz 'Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. DATE DRAWN 4/4/2024 DRAWN BY E.R ���® SHEET# PV-12.3 '23 Ind All d6hts com or ll '" _ TITLE RAIL SPEC ®Ar IRON RIDGE QuickMounta o Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves l When integrating with a home,solar attachments --- i THESE DRAWINGS ARE SUBJECT TO must be dependable for the lifetime of the rooftop. - - ` f ' COPYRIGHT PROTECTION BY US LAW. Due to recent innovations,many asphalt shingles -- I — n - -_I�q _ -_ REPRODUCTION IN ANY FORM IS i EXPRESSLY FORBIDDEN WITHOUT PRIOR have bonded COUfS6S.A mount that protects Without - _ --___ — ��.._ '"I `- - '� -' —'- WRITTEN APPROVAL FROM CURRENT the need to shingles can real) seed things U f �'` RENEWABLES ENGINEERING INC. pry 9 Y P 9 P } ? (j�/J Halo UltraGrip®(HUG®)is here to respect the roof. --- J- 1 & Its Halo is a cast-aluminum barrier that encases the - -'��== ' _ __ _ Current UltraGrip,our industrial-grade,foam-and-mastic - - - - Renewabtes seal.This allows HUG to accelerate the installation Erlgln@C'rl(1.g process and provide the utmost in waterproofing Hit the rafter? protection.Give your roof a HUG luck?Install'the rest. ® When you • ••• to ••! Miss the rafter?Try it again. Still you can • _• another •than 3 screws misi the rafter, CURRENT RENEWABLES Only 2••Structural Screws are needed. er is •und,install 3rd and final screw. secure six screws•the left or right.If If • _ to•eck ENGINEERING INC. 1760 CHICAGO AVE SUITE -- -- - -- ---- - J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 i -Mufti-Tiered Waterproofing WWW.CRENG.CO HU&utilizes a mut"ered stack of CONTRACTOR INFO t' componems.to provide revolutionary Trusted Strength 8e Less Hassle waterproofing prolecion.The Halo cast- aluminum,raised perimeter foundation surrounds.the UltraGrip base-a foam- Structural Capacities of HUG®were reviewed in ed mastic seal combination that many load directions,with racking rail running preveilis water intrusion by adhering Mon g with the shingle surface. cross-slope or up-slope in relation to roof pitch. sealin � Halo_UltraGripTM is part I For further details,see the HUG certification EZSYS of the ouickMount3 letters for attaching to rafters and decking. �,. roduct line. ---- - ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, IronRidge designed the HUG,in combination NEW YORK,11952 UltraGrip Seal Technology -_ _ =_ ;I with the RD Structural Screw to streamline PH:(631)779 7993 services@e2sys.com HUG UltraGrip utilizes.a state-of-the - — - - installs,which meads the following: Licence-ME-52689 art seal design that uses a unique; foam-and-mastic combination.The., !`r (MASTER ELECTRICIAN) foam-backed adhesive provides an _ No prying shingles Licence-HI-67461 entirely new flashing system that.,- No roof nail interference (SUFFOLK HOME IMPROVEMENT) conforms and adheres.to every nook 25-Year warranty • No pilot holes necessary Solar Individual and cranny of composition shingles a Product guaranteed free filling gaps and shingle step-downs -5 of impairing defects. • No sealant(in most cases) Permit Package (up to 1/8"in height). :. _ _ ___ • No butyl shims needed TIMOTHY OBRIEN Attachment structural Water Seal UL 1 _ Design Ratings 8.800KW Grid Tied Systerd Loading Photovoltaic System 1130 SALTAIRE WAY, Rafter&Deck Mounting Options MATTITUCK,NY 11952 The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUG®t0 the roof rafters,the roof Rev Description Date d HUG has been and certified for the UL 441 Section UL 2703 mechanical •'���• �.'�. �;; deck,or both with our custom-engineered A INITIAL DESIGN aiarzoza Triple Rated&Certified RD(rafter-or-deck)Structural Screw.The RD tested and rated to compliance with 27"Rain Test'and and bonding P ss`" Structural Screw anchors HUG to the roof to Respect the Roof '�,• "� - support 1004(Ibs)of the International TAS 100(A)-95 requirements.See , with to k of w sealing washer,completing uplift and 368 Ibs � UL 2703,441(27) � the stack of waterproofing barriers.See p� ( ) Building Code& Wind Driven Rain Flush Mount Manual OPPORTUNITY TIMOTHY OBRIEN Intertek- TAS 100(A)-95 __.__.: backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. - -- -- — - - --"-' � PROJECT# 5002 ® ® DATE DRAWN 414/2024 DRAWN BY E.R c 2023 - ! SHEET# PV-12.4 TITLE ATTACHMENT SPEC 28357 Industrial Blvd. �r��r��rrr 28357 Industrial Blvd. A&L IRONRIDGE Hayward,CA945a5 lronR dge.c m ,�,,Ir I RON RI QOE 1-800 227 95 5 IronRidge.com IronRidge.com Attn:Corey Geiger,COO,IronRidge Inc. Date•September r,2021 The parameters and adjustments allowed in the span tables are defined as the following: . 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-16 Table 1.5-1. THESE DRAWINGS ARE SUBJECT TO Re:Structural Certification and Span Tables for the IronRidge Flush Mount System COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 2. Wind speed shall conform to ASCE 7-16 Fig.26.5-1 B(for Risk Category 11)and applicable state&local EXPRESSLY FORBIDDEN WITHOOT PRIOR This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The county/city amendments to the IBC. No special wind topographic features are included and both topographic WRITTEN APPROVAL FROM CURRENT contents of the letter shall be read in its entire before applying to an ro project design.The Flush Mount System is a coefficient Ku and wind round elevation factor Ke are taken as 1.0. RENEWABLES ENGINEERING INC. ty YP J 9 Y ( ) g O proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface_ PV modules are supported by extruded aluminum XR Rails 3. Snow load used in the span tables is the ground snow and shall conform to ASCE Fig.7.2-1 and and secured to the rails with IronRidge mounting clamps_The XR Rails are side mounted to a selected roof applicable state&local county/city amendments to the IBC.If the local jurisdiction specified snow load is in the Current format of a flat roof snow,it shall first be converted to a ground snow following the local building code/ Renawable.S. attachment with 318"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables.No special snow conditions are considered that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding,retention,or ponding snow.No rain-on-snow surcharge load is Engineering components are shown in Exhibit EX-0015. considered.The span tables do not apply to buildings which are intentionally kept below freezing,kept just above freezing,or unheated_ CURRENT RENEWABLES ENGINEERING INC. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 1760 CHICAGO AVE SUITE 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: J-13,RIVERSIDE CA 92507 listed below,for the load conditions and configurations tabulated in the attached span tables. PHONE:(951)d05-1733 (a)For ground snow no greater than 42psf:SS s 2.Og for Site Class A,B,C,&D. W W W.CRENG.CO ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf.Ss 51.Og for Site Class A,B,C,&D. CONTRACTOR INFO 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:SS s 1.5g for Site Class A,B,C,&D. 2020 Building Code of New York State(BCNYS-2020,Published in November 2019) • 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in Report SEAOC(Structural Engineer Association of Califomia)PV2-2017 Wind Design for Solar Arrays which the zones share the same External Pressure Coefficients(GCp).Roof zones comprising each group along with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point,shall C`SYS8 the respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones provided in be the lesser of the following two conditions:40%of the allowable span provided for the respective load ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8"to 45".The tabulated spans are applicable when the &configuration condition from the span tables,or 36". ELEMENT ENERGY LLC. 7470 SOUND AVENUE,'MATTITUCK, following conditions are met 7. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over NEW YORK,11952 a minimum of three spans. PH:(631)779 7993 1. Span is the distance between two adjacent roof attachment points(measured at the center of the services@e2sys.com attachment fastener). 8. No splices are allowed in the rail cantilever.For each XR splice type install per the following requirements: Licence-ME-52689 (MASTER ELECTRICIAN) a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans,or the outer 2/3 of end spans. Licence-HI-67461 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system)_Spans are calculated b) BOSS Splice can be installed at any location within a span. (SUFFOLK HOME IMPROVEMENT) based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems. 9. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded.If Solar Individual 3. The underlying roof slope,measured between the roof surface and horizontal plane,is 80 to 450. such conditions are encountered contact support@ironridge.com. Permit Package 4. The mean roof height defined as the average of the roof eave height and the roof ridge height measured TIMOTHY OBRIEN from grade,does not exceed 30 feet. 8.800KW Grid Tied 5. A clearance from the underside of the array to the roof surface of 2"minimum shall be provided and the Photovoltaic System height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not 1130 SALTAI RE WAY, exceed 10"_ MATTITUCK,NY 11952 6. Module length and area shall not exceed the maximum values listed on the respective span tables. Rev Description Date A INITIAL DESIGN I 414r2D24 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount Installation Manual and other applicable standards for the general roof construction practice. OPPORTUNITY TIMOTHYOBRIEN PROJECT# 9002 @ 2021 IronRidge,Ina NY Flush Mount System Certification Letter-1 @ 2021 IronRidge,Inc. NY Flush Mount System Certification Letter-2 DATE DRAWN 414/2024 DRAWN BY ER SHEET# PV-12.5 TITLE CERTIFICATION s 28357 Industrial Blvd. 28357 Industrial Blvd. AdAk'R0NR'DGE Hayward,CA94545 � Hayward, 5 1-800-227-9523 //� 1-800-227-9523 -9523 IronRidge.com IRONR'DGE IronRidge.com 10- Systems using CAMO module clamps shall be installed with the following guidance: a) For single module installations(orphan modules)using modules with a length greater than 67.5",CAMO The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no clamps shall not be installed in regions that experience ground snow loads of 70psf and greater.Such consideration of the structural adequacy of the chosen roof attachments,PV modules,or the underlying roof supporting scenarios are shown by asterisks in the applicable span tables. members.It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the b) CAMO will function within a module's design load ratings.Be sure the specific module being used with aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. THESE DRAWINGS ARE SUBJECT To COPYRIGHT PROTECTION BY US LAW. CAMO meets the dimensional requirements Shown in the figure below and that the module selected is REPRODUCTION IN ANY FORM IS suitable for the environmental Conditions of a particular project. --` - EXPRESSLY FORBIDDEN WITHOUT PRIOR .�_ F,�I�jy: "- WRITTEN APPROVAL FROM CURRENT Sincerely, _ttiJrp O 2021 .09.0/7 RENEWABLES ENGINEERING INC. Module Gloss/Cells 1 5:45: 6 Current li = Ito — Ren@Wables - Engineering { � 1 Rome Cornponbc�ty: - X=12-22mm { Y=15-40mm CURRENT VEERING INC. f I Gang Xuan,PE ENG1760 CHICAGO AVE SUITE I Y� r W Senior Structural Engineer J-13,RIVERSIDE CA 92507 --ice X PHONE: 05-1733 —ice W W.CRENG.ENG.CO Figure i_CAI O Module Frame Dimensional Requirements CONTRACTOR INFO Span values for Exposed and Edge module conditions,as defined below,are included in the attached span ' tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge modules shall be the lesser of the following two:(1)The span value for the Exposed or Edge module condition; _ _ (2)The span value determined by site wind speed and ground snow load.Additionally,irrespective of the lesser �• span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO.clamp usage C 2 YSs limitation detailed in note 9 of page 2 shall apply to the respective condition. ELEMENT ENERGY LLC. 1. Exposed Module conditions: 7470 SOUND AVENUE,MAT ITUCK, :NEW YORK,11952 PH:(631)779 7993 A module is defined as Exposed(per Section 29.4.4 of ASCE 7-16)if the distance from any of its free services@e2sys.com Licence-ME-52689 edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge,rake,Or (MASTER ELECTRICIAN) hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from its free edge to any Licence-HI-67461 other adjacent array or panel is greater than 4 feet (SUFFOLK HOME IMPROVEMENT) The allowable spans and cantilever shall only be applied to the portion of rail directly under Exposed Solar Individual Modules. Permit Package TIMOTHY OBRIEN 2. Edge Module conditions: - — 8.800KW Grid Tied A module is defined as an Edge Module when its distance from any side of the module to its facing perimeter roof edge such as eaVe,ride rake,or hi 1s less than 2 times the height of the area 2hz Photovoltaic System P 9 ( 9 , P) 9 Y( ) where h2 is measured from the roof surface to the top surface of the module- 1130 SALTAI RE WAY, The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. MATTITUCK,NY 11952 Additionally,if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered Rev Description Date for this span adjustment. A INITIAL DESIGN 4141202 OPPORTUNITY TIMOTHYOBRIEN ©2021 IronRidge,Inc. NY Flush Mount System Certification Letter-3 ©2021 IronRidge,Inc. NY Flush Mount System Certification Letter-4 PROJECT# 9002 DATE DRAWN 4/4/2024 DRAWN BY E.R SHEET# PV-12.6 TITLE CERTIFICATION