Loading...
HomeMy WebLinkAbout50699-Z tt � TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50699 Date: 5/17/2024 Permission is hereby granted to: Constantin-Guild, Jennifer................ __w —_..........................__ �www ....._a....._ .....�_www_...._._._ ._ .. ww....._._... 400 J-jLegion Ave ......._......_ m Mattituck, NYww 11952 _._........_ _ www.. .....�_. ......... ------ _ To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 400 Legion Ave, Mattituck SCTM # 473889 _..... �w_.............. ._ _�www_......__...M.._ _w w.......__ _.....�ww..... Sec/Block/Lot# 142.-2-8 Pursuant to application dated 4/5/2024 and approved by the Building Inspector.. To expire on ..11116/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector TOWN OF SOUTHOLD —BUILDING DEPARTMENT Town ]-loll Annex 54375 Main Road P. ®. Box 1179 Southold, NY 11971 0959 Telephone (631) 765-1802 Fax (631) 765-9502 Date Remveci APPLICATION FOR BUILDING PERMIT For Office Use Only ru PERMIT NO. �� _..... Building Inspector:,.... ..__..... _ 02 �A Ii Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an 71 Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY. Nam j 1 C o 1� 1n - U_I scTM#l000- Ub - 0,--). 00 - (DO . Lo 0 Project Address; oo L—� l(7Yl &v`e� I n1 S Phone#: 3 .. �' (7 r Email: Mailing Address: �� Y M 4-t4C&_i lJ. CONTACT PERSON: Name: L o rra l p e w 11 Mailing Address: -741d SoLAAd 61Vt� MGt-��1 a d L"l CJoff-, Phone#: (P 3 I -3 9 9 �-7 0 LI I Email: P r .i+5 fi DESIGN PROFESSIONAL INFORMATION. Name: i Mailing Address: n Phone#: Email: CONTRACTOR INFORMATION: Name: 1 11')��"i Vl / Lq Mailing Address: "® O VO / ► 1 `I'1 cr,, �V ;A n Q � q5 Phone#: 3 ` , `� ) Email: p "` s!?� DESCRIPTION OF PROPOSED CONSTRUCTION p � , �ated �� °of project: ❑New Structure ❑Addition ❑Alteration ❑Re air ❑Demolition Estim Cher l in54-s-cl S ). VW . Will the lot be re-graded? ❑YesXNo Will excess fill be removed from premises? ❑Yes)�eiVo PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covena is and restrictions with respect to this property? ❑Yes IF YES, PROVIDE A COPY. heck ox After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Laf-rr&I'Au � I-PC , uthorized A nt El Owner Signature of Applicant: Date: L.Ot,11 C�t�1F STATE OF NEW YORK) Notary Public,State of New York SS: No.01 R06314813 Qualified in Suffolk County COUNTY OF �iA ) Commission Expires November 17,20 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the or-)-h,-/L Ctlzl' (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowl eqf A8Qeff;and that the work will be performed in the manner set forth in the application file therewith. Notary Public,State of 0 New York No.01 R0 r314813 Qualified In Suffolk,County Sworn before me this Commission ExPires November 17, V4 day of Z I 202 ry Public PROPERTYT I TI (Where the applicant is not the owner) I, SO 1 r 1-S4'iX(ewe) - )t(I IJ residing at 40 O h r Lurr6 ►e--, i" ll aSZ do hereby authorize EfMi'4 Eft -r- mW,�-tjn, to apply on my behalf to the Town of Southold Building Department for approval as described herein. 4 � 4 1.7 LJ Owner's Signature Date e PA ���� � Notary Praf da St Me of New York No 01 f1063 l 48'13 Print Owner's Name O:►oiifoed wry Suffolk County � r'l�� Commission Expires November'I7,20 f 7`- 2 ff01 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 w, M W ro ,err soutloldtownn ov seand southoldtown ny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: -" /er la 1 Company Name: IeM CA4 Erl e, L , Electrician's Name:Jn.a rvvC_,, License No.: (no q _ 1�t Elec. email: I��r'm i+5 12� ca.s �S, C-D)✓P Elec. Phone No: LEI request an email copy of Certificate of Compliance Elec. Address.: 14-7 o �� 0,Y(� m�k1'�..C� . l l ow JOB SITE INFORMATION (All Information Required) Namea U _ ' Addressor l G� Cross Street: Phone No.: Bldg.Permit #: email: PfYYn i Tax Map District: 1000 Section: I H Block: 0 C4_ Lot: 60 r BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footagew Circle All That Apply: Is job ready for inspection?: YES 0 NO F�Rough In F] Final Do you need a Temp Certificate?: YES NO Issued On "Temp Information: (All information required) Service SizeF11 Ph[:]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire ReconnectnFlood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 M H Frame Pole Work done on Service? Y ON Additional Information -:MSS -a ll .F[L"h (-0 0 ►-n u�.�rt+�,L, S�1 a i�✓ PAYMENT DUE WITH APPLICATION Tam H-lKu6 (All-Black) ALL BLACK MONO PERC MORE POWER � 2 ) Industry Leading*roduet Warranty on Materials Years and Wor ansh p Module power up to 405 W ",�.n. 405 Wp Module efficiency up to 20.7% 25" �om„��.�� Linear Power PerformanceWarranty* Lower LCOE&system cost 111 year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% "Aitbin"to d a terrrus and condstaor s conta nad In the appOcabte C anadtan Soiar limited , WamranlyStareme�nlr,klsothls;2*u arN6argedpro,�ductw�nxrantyis"aitableonyforprod- Comprehensive LID/LeTID mitigation Lets r sUled and"em�at�rrtl on aea denrtaw rootops rare cerraatn re ions �� 11' technology,up to 50%lower degradation - MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2015 t Quality management system Better shading tolerance ISO 14001:2015 t Standards for environmental ruin ement system ISO 45001:2016 t International standards for occupational health&safety PRODUCT CERTIFICATES* MORE RELIABLE IEC 61215 t IEC 61730 t CE t INMETRO UL 61730!IEC 61701 t IEC 62716 Take-ewvay i Minimizes micro-crack impacts ovE �4g, If', t The specific certificates applicable to different module types and markets will vary, and therefore not all of the certifications listed herein will simultaneously apply to the ppp Heavy snow load to 7000 Pa, � u p products you order or use_Please contact your local Canadian Solar sales representative wind load up to 5000 Pa* to confirm the specific certificates available for your Product and applicable in the regions " .,,. .. in which the products will be used. CSI SOLAR(USA)CO.,LTD.is committed to providing high quality solar photovoltaic modules,solar energy and battery storage solutions to customers.The company was recognized as the No.1 module supplier for quality and performancetprice ratio in the IHS Module Customer Insight "Pending testing confirmation.For detailed information, Survey.Over the past 20 years,it has successfully delivered over 67 GW please refer to the Installation Manual. of premiumt,quallty solar modules across the world. CSI SOLAR(USA)CO.,LTD. 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94597,USA I www.csisolar.com/na I service.ca@csisolar.com ENPHASE NOW Microinverters a i Our Newest!Q8 Wicreinver tars are the'mdustrf's first miicrogris}-fbrrnw g,sous-s- Ur tr t arrd as 'j #e r1e!1rlicrainyerters with split-pease Gower cari3tersiorl apab�it'% to co nee -�E y s gcrs power to AC power efficien.tiy.The brain Of ylle selwliconductcr-based rpicroir.vertar is our proprietary appNcaton-specific rtegrated eirct�t(�SJC)w. ich enables`th �r Wei U e"— ire' a:liorain�reraer to operate irl gr -ti�4 or a -grid i?ios. 1^°s chip is b�ii€ in advanced ( "�) co ,55r a tscilrioiagY whh high speed o^igitai logic and has super-mot response dMes Fasterirr ,er,Wkh, a,^i aging i as is and grid everfts,adevfating sanstrairtts or,!,:zttArV sizing for noose tw _R caking errerg`,r systems. re grid is rice' Wfore t ° one rrAor51 "1 eir4 't l�� µ iwtstasi °i Part of the Enphase Energy System,IQ8 Series iQ*Series Ncroanrerters redefine reliabiky Mocrafnverters integrate wilt,the Enphase.10 Battery, standards with more than one mocn cumulative � r the 4test I; Enphase 10 Gateway,and the Enphase Agra monitcring hours of power-on testing,enabling an industry- and analysis software. leading limited warranty of up to 25 years. i I4ulAIIMM OHea .it the Wast, riae 'griiC BU�p �� Remote omalic uPdates for �e31 grid reti,t'�rr3rf "dt'li Connect PV modules quickly and easily to IQ8 Series IQ8 Series Iicroinverters are UL Listed as 4to Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Dawn Equipment and conform with Configurable to or2 a`amide cable with plug-n-play MC4 connectors. various regulations,when installed according to rangeofgridpraffies manufacturer's instructions. �+ Meets CA Rule 21(t1L 1741-SA) requirements ©2022 Enphase Energy.All rights reserved._nphase,the Enphase logo,IQ8 Microinverters,and other 'Only when installed.with iQ System Controller 2, names are trademarks-if-Enphase Energy,Inc.Data subject to change. meets UL 1741. "I08 and IQBPlus support ort split vase,2404 '08SP-03-0002-01--1\I-US-2022-03-i? instailationsonlry. p IRONRIDGE Flush Mount System w IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced (lashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tasted i RE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. �f available in most states. Class A Fire Ratingi4 � ��1 a« r Design Assistant 'Certified to maintain the fire resistance ® ' Online software makes it simple to rating of the existing roof. luii11170;� create, share, and price projects. UL 2703 Listed System %r ' 20 ear Warranty )a `Entire system and cmpents meet , n ^ % „ % Twice the protection offered by components newest effective UL 27013 standard, � competitors. Workers' IttAirc I compensation CERTIFICATE OF INSURANCE COVERAGE Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PA 1.To be completed byymNYS disability and Paid Family Leave benefits carrier or licensedused insurance agent of that Carrie la.Legal N rn ENERGY LLC of Insured use street address on 1 b..-������.usines.����T _._ �� _M._. g t h+} Business Telephone Number of Insured 7470 SOUND AVE MATTiTUCK,NY 11952 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Locatior,of Insured(Onlyregufred if coverage is specificaliyfirnrted to coilain locations in New York Stare,i e.,Wrap-Up Policy) j 233366{}4 2 Name Being Address of Entity(Requesting Pr..............o r Se of Insurance ntLife. ..._., .....w... .....m.. ........, .,. .. Proof of Coverage �3a.Name of Insurance Carrier (En Listed as the Certificate Holder} Insurance Comparty TOWN OF SOUTHOLD y 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"la" SOUTHOLD, NY 11971 DBL567527 3c.Policy effective period 01/01/2023 to 12/31/2024 4. Policy provides the following benefits: ® A Both disability and paid family leave benefits_ B.Disability benefits only. C.Paid family leave benefits only. S. Policy covers: ® A.All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. 0 B.Only the following class or ctasses of employer's employees: Under penalty of perjury,I cert11 i11 fy Ihat I am an authorized''slat� tative or 6. d agent o the insurarice carrier m e above and thak the named insured has NYS Disability andfor Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/1012023 By (v4a,&t (Signature of insurarce carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number §1"29--sigg Name and Tifle Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2 µTo be completed byµ the nNYS Workers'compensation Board(only it Box 46,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Articfe 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Empinyeej Telephone Number Name and Tille Please Note:Only saran.,. ca rriers licensed to write NYS.......disability paid family leave benefits insurance policies and NYS licensed insurance agents of those r surance carvers are authorized to issue Fcrm D ` 8-120.f Insurance brokers are NOT authorized to issue this form. D8.120.1 (12-21) ' li CERTIFICATE OF LIABILITY INSURANCE DATE IMM7111D12/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURERS), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT; If the certificate holder Is an ADDITIONALOV y(I )must have AC1OiTIONAt INSURED provisions or be endorsed, If SUBROGATION IS WAIVED,subject to the terms and ilo'yfi Certain poyicles may requlne an endorsement. A statement on I,hle Certificate does not confer rights to the certificate hoTldorsePRODUCERROBERT S. FEDE INSURANCE AGENCY 5",t7, _.......M_23 GREEN STREET,SUITE 102rl l>t� HUNTINGTON,NY 11743 ROBERTS.FEDE IN aE ,a ATLANTIC CASUALTrINSS.RANCE MSURINSURED . 524Element Energy LLCC INS cDBA ELEMENT ENERGY SYSTEMS ��o- D 7470 SOUND AVENUE --- -r MATTITUCK, NY 11952 rtE: F. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS,_.�... 110 EXCLUSIONS TYPE O IN .,., _ _. w. ob LT, F Idr✓@3URANCI"m POLICY NU ; ... ._. LIMITS COMMERCIAL GENERAL LIABILTfY L1450036873 EACH OCCURRENCE A X X 7/14(2p23 7M4l2024 ..._, „_..., ..,. 77 CLAIMS-MADE OCCUR 2F2AwrGi y: . t 1tI0.0t30 ..... .. WIAA3892038 X Contractual Lia.. ._ 711 9l2022 711912024 Prl�woNA�a ADv irLxiRv $ 1=000 _... _.. GEML AGGREGATE LIMIT APPLIES PER: POLICY a PECOT ❑LOG RAL AGGREGATE .. 3,000,0W..,....v GC-r� .._.. i . OTHER„ PROMCTS w'COWAO; 5 a IMI AUTOMOBILE uAsu ITY _...w ANY AUTO ._.......... eODILY INJURY{Per person) s OWNED SCHEDULED .... AUTOS ONLY AUTOS AOr1ILY INJURY(Per—dent) S HIRED - NON-OWNED I I i't:`%I'CwT r?I'AA...AQ....... ..-.. ......., „w AUTOSONLY AUTOS ONLY S y ..._...................... W. ....._.... a $ UmINIE r A LIAB { OCCUR ° EACH C",�!rCURRENCE-E $ ., EXCESS LIAR CLA -M .. ..... .....w.w AGGREGATE $ OEC RETI fir L�i CIOUKUse"K ON 124494445 t B �IOFFDiCERnNEMBER EXCLu0E0+ Y I NIA 7!i 32023 7113 024 L E�ACH ACCIDENT s 1 I p ANY PROPRIETOWARTNERIEXECUTIVE .. ........ .... .,...,...,...,...a r desaibe under EL DISEASE-EA_EMP�LOYE4 3 µ O^�SrRr6*T'EdG ERATc Ia L�Drs �.'.POt,fC'Y LIMIT'......t ..�_.H -111-.- I —I -- L..... ....... .. ' -.1.11. NY State DBL DBLse�52T n2/31t2024 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS 1 V EHICLES(ACORD 101,Additlonai Remarks SrbeAure,maybe atimW W elm Space Is regtdredl I CERTIFICATE HOLDER IS ADDITIONAL INSURED Certtificate holder and Property Owners are hereby named as additional insured(using CG 2010 and CG 2037)(Blanket)on a non contributory basis including completeted operations on GL Waiver of subrogation is applicable to General Liability. 30 day notice of cancellation applies. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WRL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Ro� S. Feces 1988-2015 ACORD CORPORATION. All rights reserved. ernon �e»n�erni� Taa Ar`r1Dn ,.. ,.a i .. :ems _ . _.4 s ArnMn NYSE New York State Insurance Fund PO Box W699,Albany,NY 12206 J nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) A A A A A A 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 124A 444-5 369075 07/13/2023 TO 07113QG24 7/11/2023 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO, 2449 444-6, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:lIWWW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STAT S� CpE FUND DIRECTOR,I NSU RANCE FUND UNDERWRITING qq Li I-IA - CODE INFORMATION ROOF MOUNT SOLAR PERMIT PACKAGE THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC OF NEK. POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: ��PO�RS A. 1g J O E CO N STANTI N-GUILD yO,p� 2020 NEW YORK BUILDING CODE-BUILDING - ` 2020 NEW YORK BUILDING CODE-RESIDENTIAL 12.000KW DC GRID TIED PHOTOVOLTAIC SYSTEM 2020 NEW YORK BUILDING CODE-EXISTING BUILDING I w 2020 NEW YORK BUILDING CODE-PLUMBING ti 2020 NEW YORK BUILDING CODE-MECHANICAL JF�p 1os793 400 LEGION AVE, MATTITUCK, NY 11952 2020 NEWYORK BUILDING CODE-ENERGY CONSERVATION SIONP 2020 NEW YORK BUILDING CODE-FUEL GAS Exp:9/30/2025 2020 NEW YORK BUILDING CODE-ACCESSIBILITY STAMPED 03/29/2024 2020 NEW YORK FIRE PREVENTION CODE BUILDING INFORMATION 2017 NEWYORK NATIONAL ELECTRICAL CODE THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 2 STORY HOUSE SINGLE FAMILY RESIDENCE EXPRESSLY FORBIDDEN THOUTPRIOR WRITTEN APPROVAL FROMM CURRENT CONSTRUCTION TYPE:V-B OCCUPANCY:R3/U AHJ :TOWN OF SOUTHOLD RENEWABLES ENGINEERING INC. ROOF:COMP SHINGLE APN:1000142000200000000 Current PV SYSTEM SUMMARY: , SYSTEM SIZE(DC) : STC:400 x 30=12.000KW DC }s}J 0 Engineering Engineering PTC:376.70 x 30=11.301 OKW DC SYSTEM SIZE(AC) 8.700KW AC @ 240V CURRENT RENEW I NC: LES NC: MODULES (30)CANADIAN SOLAR:CS6R-400MS-HL nso RIVERSICHICAGDE AVE SUITE507 J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 W W W.CRENG.CO MICRO-INVERTERS ENPHASE:IQ8PLUS-72-2-US AERIAL VIEW VICINITY VIEW CONTRACTOR INFO MICRO-INVERTERS QTY 30 TILT 21°,30°,30°,23°,23° : ss r , AZIMUTH : 132°,222°,42°,222°,42° oc ROOF COMP SHINGLE / RAFTER/TRUSS SIZE 2"X10"/2"X8"RAFTER @ 16"O.C./2X4 RAFTER @ 24"O.C. RAFTER @ 24' O.C. E2SYSU ATTACHMENT TYPE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP WITH IRONRIDGE XR-100 ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, K. EXISTING 200 AMPS MSP WITH 200 AMPS MAIN NEW Y1)779 9 52 MAIN SERVICE PANEL "`',,, �• services@e2sys.com BREAKER ON TOP FED j Licence E INTERCONNECTION LOAD SIDE TAP EL (MAS TER ELECTTRICIARICIA 1 ' N) Licence-HI-67461 OCPD RATING 50 AMPS L '. (SUFFOLK HOME IMPROVEMENT) UTILITY PSEGLI Solar Individual GENERAL NOTES: two _ _ _ ;, Permit Package [2. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES SHEETINDEX JOECONSTANTIN-GUILD PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED . ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND UL1703 PV-1.0 COVER PAGE 12.000KW Grid Tied 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED PV-2.O SITE PLAN Photovoltaic System 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS- PV-2,1 ROOF PLAN 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT IS THE NECESSARY TO INSTALL A SUPPLEMENTAL 400 LEGION AVE, GROUNDING ELECTRODE• PV-3.0 STRUCTURAL MATTITUCK,NY 11952 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE PV-4.0 ELECTRICAL 3LD MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" Rev Description Date 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS- PV-5.0 ELECTRICAL SLD A I INITIAL DESIGN 31232024 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6" 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NEC.• PV-6.0 BOM Al UPDATED DESIGN 3rz7/2o2a 14. PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER,AND SYSTEM PV-7.O SIGNAGE A.2 UPDATEDDESIGN 313012024 COMPLIES WITH690.35. OPPORTUNITY JOECONSTANTIN•GUILD 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.• PV-7.1 PLACARD PROJECT# NA 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER THE NEC,THE INSTALLATION PV-8.0 M ICROI NVERTER CHART DATE DRAWN 3r3ono24 STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. DRAWN BY E.R \� 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8"ABOVE ROOF SURFACE. PV-9.O SAFETY PLAN SHEET# PV-1.0 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL BE RATED FOR EXPOSURE;TYPE NM CABLE PV-10.0 SAFETY PLAN TITLE ALLOWED IN PROTECTED LOCATIONS.WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS THROUGH OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT PV-11.0+ SPEC. SHEETS COVER PAGE 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS,STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE TO THE PURPOSE INTENDED: NOTR324.6.1 PATHWAYS: LEGEND NOT LESS THAN TWO MINIMUM 36-INCH WIDE PATHWAYS ON SLPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON PROPERTY LINE NEW,, ALL BUILDINGS. A AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER ���OEgt �4 O•p� FENCE 1 gg' DRIVEWAY SIDE OF THE ROOF. I * F FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM I _ sP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE ( 18'-10 ue SUB PANEL y 106793 OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS :' DRIVEWAY WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR rr C AC DISCONNECT ROFESSION� MECHANICAL EQUIPMENT. f.e°•. .: ..: .;: '.:.: .: ' C COMBINER Exp:9/30/2025 W R324.6.2 SETBACK AT RIDGE: 81 -11 FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 / ❑ STAMPED 03/29/2024 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN i „ I -� AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A Q -52-9 �B JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO HORIZONTAL RIDGE. COPYRIGHT PROTECTION BY US LAW. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 z II REPRODUCTION IN ANY FORM IS PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A O I ❑ MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A 0 WRITTEN APPROVAL FROM CURRENT HORIZONTAL RIDGE. (n ,% RENEWABLES ENGINEERING INC. (D \ 23'-7" ROOF OBSTRUCTIONS R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELS w AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED �^ _ ROOF ACCESS POINT THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE 4: - _____—__—__ _____—________—__ __ -_—__-- �— t ' Current AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. /I 149'-10" Renewables A -PATHWAY ON STREET FENCE/GATE PROPERTY LINE Engineering OR DRIVEWAY SIDE OF ROOF B -FIRE ACCESS POINT CURRENT RENEWABLES ENGINEERING INC. w/m/Eirm CHICAGO AVE SUITE CA 36"ACCESS PATHWAYS PHONE: 5SI-005-1733507 W W W.CRENG.CO 18"ACCESS PATHWAYS JIM1111101M CONTRACTOR INFO NOTES: ENLARGE VIEW 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL SITE CONDITION AND MEASUREMENTS. (N)COMBINER 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS EP_SYS� INCORPORATED INTO THE 2017 NEC AND UL (N)AC DISCONNECT STANDARD 1741. 3. EXISTING ROOF VENT SHOULD NOT BE (E) UTILITY METER ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, COVERED. NEW YORK,11952 (E)MAIN PH:(631)779 7993 NOTE: SERVICE PANEL services@e2sys.com REVENUE GRADE KWH PRODUCTION METER Licence-ME CERTIFIED TO ANSI C12.1-2008 OR ANSI CA 2.20 ROOF OBSTRUCTION (MASTER ELECT Licence- RICIARICIA N) STANDARDS. c Ac um Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) � > pc (E)SUB PANEL Solar Individual Q - Permit Package z JOE CONSTANTIN-GUILD Q (N)AC DISCONNECT 12.000KW Grid Tied w Photovoltaic System J _ i 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3123/2024 / A.1 UPDATED DESIGN 3127/2024 A2 UPDATED DESIGN 3/30/2024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# DATE DRAWN 31 3I30l2024 SITE PLAN 36"ROOF ACCESS POINT DRAWN BY LPV- ROOF LINE 36"ROOF ACCESS POINT SHEET# Pv-z.o &SC-ALE: TITLE 1/32" = 1 t-0" SITE PLAN ARRAY AREA LEGEND _ EAVE TO ROOF TOTAL #OF RIDGE ARRAY AREA ROOF AREA AREA Cif IVf ROOF ROOF TYPE AZIMUTH MODULES DIMENSION (Sq.Ft.) AREA COVERED BY COVERED BY (Ft.) (Sq.Ft') ARRAY(%) ARRAY(%) UM UTILITY METER A. (4o�'P #1 COMP SHINGLE 132 9 14.58 189.18 2111 8.96 #2 COMP SHINGLE 222 6 13.50 126.12 2111 5.97 MSP MAIN SERVICE PANEL r #3 COMP SHINGLE 42 5 13.50 105.10 2111 4.98 29.87 W #4 COMP SHINGLE 222 5 8.50 105.10 2111 4.98 SUB SUB PANEL 2ir V #5 COMP SHINGLE 42 5 8.50 105.10 2111 4.98 106793 AC DISCONNECT A'��FESSIONP� Exp:9/30/2025 (N)#30 CANADIAN SOLAR: CS6R-400MS-HL COMBINER STAMPED 03/29/2024 JUNCTION BOX THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS ROOF#5 ❑ MODULE EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (N)COMBINER ROOF OBSTRUCTIONS (N)AC DISCONNECT . Current (E) UTILITY METER '._ 5 . RanewaL Engineering (E)MAIN SERVICE PANEL CHICAGO AVE SUITE CURRENT RENEWABLES ROOF#3 ENGINEERING INC. I.I I c A. um J763,RIVERSIDE CA 92507 ROOF#4 PHONE:(951)-405-1733 QsuB W W W.CRENG.CO z (E)SUB PANEL CONTRACTOR INFO LLU (N)AC DISCONNECT STRUCTURAL NOTES : EPSYSB 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE ELEMENT ENERGY LLC. COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE 7470 SOUND AVENUE,MATTITUCK, 52 PROPOSED PV INSTALLATION ONLY. NEwY 9 PH:(631)779 79 7993 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. services@e2sys.com 3. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS Licence ELECT RICIARICIA (MASTER ELN) MUST FOLLOW MANUFACTURER GUIDELINES AND Licence-HI-67461 REQUIREMENTS,. (SUFFOLK HOME IMPROVEMENT) /3 j/ ( 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL Solar Individual CALCULATIONS REPORT FOR ADDITIONAL INFORMATION. 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR Permit Package ROOF#1 ROOF#2 INSTALLER SHALL VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND NOTIFY THE E.O.R. IF THERE IS ANY JOE CONSTANTIN-GUILD INCONSISTENCY BETWEEN SITE VERIFICATION AND 12.000KW Grid Tied FOLLOWING: Photovoltaic System - ROOF 1:2x10 RAFTERS @ 16" OC SPACING WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 15 FT. 400 LEGION AVE, - ROOF 2&3: 2x8 RAFTERS @ 16" OC SPACING WITH MAX MATTITUCK,NY 11952 UNSUPPORTED SPAN EQUAL OR LESS THAN 14 FT. Rev Description I Date - ROOF 4&5: 2x4 RAFTERS @ 24" OC SPACING WITH MAX A INITIAL DESIGN 3J M024 UNSUPPORTED SPAN EQUAL OR LESS THAN 8 FT. A.1 UPDATED DESIGN 1 312712024 A.2 UPDATED DESIGN 1 3130/2024 OPPORTUNITY I JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/30/2024 \ DRAWN BY E.R \��1 ROOF PLAN SHEET# PV.2., 2 TITLE SCALE: 3/32" = V-0" ROOF PLAN MAX ROOF ROOF ROOFING ATTACHMENT TYPE FRAMING FRAMING OC PENETRATION PENETRATION MAX �0F NEyy NO TILT TYPE TYPE SIZE SPACING PATTERN SPACING OVERHANG V_ R1 A. yO,p a,�00� Z4 ROOF 1 21 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 21Sx10" 16" FULLY STAGGERED 64" ROOF 2 30 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x8" 16" FULLY STAGGERED 64" CZ I `" QUICKMOUNT HALO ULTRA GRIP RAFTER 2"x8" 16" FULLY STAGGERED 64" 24" �� 106793 �t�� ROOF 3 30 COMP SHINGLE IRONRIDGE Q /QpF NP ESSIO ROOF 4 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" Exp:9/30/2025 ROOF 5 23 COMP SHINGLE IRONRIDGE QUICKMOUNT HALO ULTRA GRIP RAFTER 2"X4" 24" FULLY STAGGERED 72" STAMPED 03/29/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current CANADIAN SOLAR:CS6RA00MS-HL Engineering CURRENT RENEWABLES ENGINEEIRONRIDGE XR-100 117600 CHIICAG(O AVE SUITE TABLE PENETRATION PHONE: E:(951ID05-IM3E CA 07 PHONE:(951)�05�1733 W W W.CRENG.CO GUIDE FOR INSTALL CONTRACTORINFO 4" (E)COMP SHINGLE TWO OR MORE ROWS OF PANELS A 12 zs^M1N.EMBED. IRONRIDGE QUICKMOUNT HALO ULTRA GRIP I I I I I I I I I I I I I I I I I I I I E2SYS8 ELEMENT ENERGY LLC. #14 X 3 X RD STRUCTURAL WOOD SCREWSI I I I I I I I I I I I I I I I I I I I 7470 TO BUSTING nSOUND AVENUE,MATMCK, N EW YO RK,11952 RAFTER PH:(631)779 7993 services@e2sys.com I I I I I I I I I I I I I I I I I I I I Licence-ME-52689 I I I I I I I I I I I I I I I I I I I I (MASTER ELECTRICIAN) O.C. HI 461(E)2"X10"/2"X8" RAFTER @ ENLARGED VIEW 2X4 RAFTER @ 24"O.C. TI tT (SUFFOLK HOME IMPROVEMENT) STACKED STAGGERED FULLY STAGGERED Solar Individual IRONRIDGE XR-100 Permit Package IRONRIDGE QUICKMOUNT HALO ULTRA GRIP ONE ROW OF PANELS JOE CONSTANTIN-GUILD CANADIAN SOLAR: CS6R-400MS-HL 12.000KVV Grid Tied SEE ENLARGED VIEW I I I I I I I I I I I I I Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 rl (E) 2"X10"/2"X8" RAFTER @ 16"O.C. FULLY STAGGERED STACKED/STAGGERED Rev Description Date 2X4 RAFTER @ 24" O.C. A INITIAL DESIGN 3232024 A.1 UPDATED DESIGN 3272024 A2 UPDATED DESIGN 3/302024 OPPORTUNITY JOE CONSTANTIN GUILD ATTACHMENT DETAILS (E)COMP SHINGLE PROJECT# PROJECT# NA _ DATE DRAWN 31302024 , \ DRAWN BY E.R SHEET# PV-3.0 TITLE STRUCTURAL BACKFEED FUSE SIZING BACKFEED FUSE SIZING MAX.CONTINUOUS OUTPUT 1.21A @ 240V MAX. CONTINUOUS OUTPUT 1.21A @ 240V (�OF NElNy0 �P pE Mom/p 'p 24.20 X 1.25 = 30.25AMPS 40A FUSES-OK (N)60A FUSED AC 12.10 X 1.25 = 15.13AMPS 20A FUSES-OK ZO 9C DISCONNECT * U G '* / SQUARE D D322NRB E�rz y , r WITH 20 A FUSES, (� W --- "; IN'3/4"OR #12,SKU:Q-12-RAW-300,THHN KNIFEBLADE, (10)IQ8PLUS-72-2-USAWG,EGC THWN-2 LOCKABLE,NEMA 3R, 09912$ Z. LARGER PVC CONDUIT ZMICROINVERTERSULLISTEDICBRANCH-1 . 7Q� S10CANADIAN ------ � ---- -----1SOLAR:CS6R-40OMS-HL 3-#6 AWG,THWN-2 I STAMPED03/29/2024 1-#8 EGC,THWN-2 I IN 3/4"OR LARGER PVC (E)1DOARATED MAIN BREAKER CONDUIT (END FED) I I THESE DRAWINGS ARE SUBJECT TO (E)1ODA RATED I COPYRIGHT PROTECTION BY US LAW. SUB PANEL 1PH,12Dn40V 60Hz I REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT (N)ENPHASE I MAN(ERVILEPANED nnsrERury RENEWABLES ENGINEERING INC. COMBINER BOX MODEL m i PH.lzorzaoveDHz NO#X2-IQ-AM1-240-4 I (E)200A/2P MAIN BREAKER TOPFE) Current %� I (TOP FED) „� p� 4,�q �,q,Fp�y YWIRE LESS /1\ - ` COMMS Engineering TEWAY (10)IQ8PLUS-72-2-US I (N)LOADCURRENT RENEWABLES MICROINVERTERS N)15A' (N)60A FUSED AC DISCONNECT ENGINEERING INC. BRANCH-2 ' I I SQUARE D D322NRB 1760 CHICAGO AVE SUITE 10 CANADIAN N I I I WITH 40A FUSES, i PHONE: RIVERSIDE CA92507 SOLAR:CS6R-400MS-HL q I I KNIFEBLADE, L- PWWWCRENG.001733 LOCKABLE,NEMA 3R, (N)LOAD (10)IQ8PLUS-72-2-US --I �11 I I UL LISTED )IOETAP (E)IDE TAP CONTRACTOR INFO tj MICROINVERTERS I I (N)20�� I I SUBPANEL BREAKER ro unuTr I /� I qfb OVERHEAD BRANCH-3 - )p! L--------- -----L � I -------- I FEED 10 CANAD so q r L EXISTING HARE RUN THROUGH CONDUIT I ��•� 3-#8 AWG,THWN-2 3-#6 AWG,THWN-2 1.06 GEC.BARE 1-#8 EGC,THWN-2 1-#8 EGC,THWN-2 COPPER FREE AIR I CSYS° " BONDED EXISTING L---------- ' AWG#12.SKU:Q-12-RAW-300,THHN (J►NADIAN IN 3/4"OR LARGER PVC IN 3/4"OR LARGER PVC LIFER TIE IN 1-#B AWG.EGC THWN-2 MODULE MANUFACTURER CONDUIT CONDUIT (E)GROUNDING ELECTRODE IN 3W OR LARGER PVC CONDUIT SOLAR CONDUCTOR#6 RARE COPPER C56R-40OMS- ELEMENT ENERGY LLC. HL 7470 SOUND AVENUE,MATiITUCK, MODULE MODEL NEW YORK,11952 MODULE(W) 400 PH:(631)779 7993 TC(W) --- NOTE: services@e2sys.com MODULE P MODULE C(A) 76.7 REVENUE GRADE KWH PRODUCTION METER CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 Licence-ME-52689 STANDARDS. (MASTER ELECTRICIAN) Licence-HI-67461 MODULE Voc(V) 36.80 (SUFFOLK HOME IMPROVEMENT) MODULE Imp(A) 12.99 NOTE: MODULE Vmp(V) 30.80 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A JOE CONSTANTIN-GUILD WIRE SCHEDULE STARTING ADJUSTMENT MAXIMUM STARTING TEMPERATURE 12.000KW Grid Tied AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT CONDUCTOR RACEWAY EQUIPMENT WIRE LOCATION WIRE APPLIED TO MORE THAN 3 CONDUCTOR APPLIED TO Photovoltaic System QTY. AMPACITY RATING (°C) FACTOR CONDUCTORS AMPACITY CONDUCTORS # SIZE 310.15(B)(16) CONDUCTORS IN 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY MA400 TTITEGIONY AVE, 11952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date 2 AC MICROINVERTER TO AC DISCONNECT EXTERIOR WALL 2 12 30 90° 12.10 0.96 1 28.80 15.13 A INITIAL DESIGN 312312024 3 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90, 12.10 0.96 1 72 15.13 A.1 UPDATED DESIGN W712024 A.2 UPDATED DESIGN 3130/2024 4 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# 5 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 12.10 0.96 1 28.80 15.13 DATE DRAWN 31 3130/2D24 6 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90, 24.20 0.96 1 52.8 30.25 DRAWN BY E.R 7 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90, 24.20 0.96 1 72 30.25 SHEET# PV4.0 TITLE 8 AC ELECTRICAL 3LD 9 AC BACKFEED FUSE SIZING BACKFEED FUSE SIZING MAX.CONTINUOUS OUTPUT 1.21A @ 240V MAX.CONTINUOUS OUTPUT 1.21A @ 240V M ,`�OF NEwyO �P pE aV/ 'p 24.20 X 1.25 = 30.25AMPS 40A FUSES-OK (N)60A FUSED AC 12.10 X 1.25 = 15.13AMPS 20A FUSES-OK 0 �0 DISCONNECT SQUARE D D322NRB , WITH 20 A FUSES, 0 AWG#12,SKU:Q-12-RAW-3DO,THHN KNIFEBLADE, 1-#6AWG,EGC THWN-2 LOCKABLE,NEMA 3R, (10)IQBPLUS-72-2-US m 099128 Z MIQBPLUSERTERS IN 314'OR LARGER PVC CONDUIT UL LISTED ��O CTRIGP� U BRANCH-1 VJ-b n A�OFESS�ONP� 10 CANADIAN N V.le SOLAR:CS6R-00OMS-HL 3-#6 AWG,THWN-2 STAMPED 03/29/2024 1-#8 EGC,THWN-2 IN 3/4"OR LARGER PVC (E)1DOA RATED MAIN BREAKER CONDUIT (END FED) THESE DRAWINGS ARE SUBJECT TO (E)100A RATED COPYRIGHT PROTECTION BY US LAW. SUB PANEL 1PH.120240V 60HZ REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT (E)20OARATED UTIRENEWABLES ENGINEERING INC. (N)ENPHASE MAIN SERVICE PANEL METERUry COMBINER BOX MODEL PH,120240V 60HZ NO#X2-IQ-AM 1-240-4 •_ (E)200A 12P /rl\\ MAINTOPFE) ®RIZOR�? Current (TOP FED) �q�ySCELL WIRELESS /I\ enieWf b1es r\ MODEM COMMS Engineering IQ GATEWAY n (N)LOAD 01. CURRENT RENEWABLES (10)IQBPLUS-72-2-US ) SIDE TAP MICROINVERTERS N)1s:m (N)60AFUSED /I� ENGINEERING INC. 41 AC DISCONNECT BRANCH-2 SQUARE D D322NRB /tom 1760 RIVERSIDE AVE SUITE N WITH 40A FUSES, J1- PHONE: RIVERSIDE-1 92607 10 CANADIAN i\ PHONE:(951)-0OS-1733 SOLAR:CS6R-40OMS-HL KNIFEBLADE, /1\ WWW.CRENG.CO N)2o�T LOCKABLE,NEMA 3R, (N)LOAD SIDE TAP UL LISTED(10)IQBPLUS-72-2-US N2DA (E)10oA2a CONTRACTOR INFO ( ) I� SUBPANEL BREAKER I I TO UnUTY MICROINVERTERS qJb n OVERHEAD FEED BRANCH 10 CANADIAN N " SOLAR:CS6R-400MS-I L EXISTING WIRE RUN THROUGH CONDUIT mom 3-#8 AWG,THWN-2 3-#6 AWG,THWN-2 s�� �U 1-#8 EGC,THWN-2 1-#8 EGC,THWN-2 AWG#12.SKU:Q-12-RAw-300,7HHN IN 3/4"OR LARGER PVC IN 3/4"OR LARGER PVC L 1-#8 AWG.EGC THWN-z MODULE MANUFACTURER CANADIAN CONDUIT CONDUIT (E)GROUNDING ELECTRODE IN 3/4'OR LARGER PVC CONDUITSOLAR CONDUCTOR 96 BARE COPPER ELEMENT ENERGY MODULE MODEL CS6R-40OMS- 7470 MATT HL SOUND AVENUE,MATfITUCK, NEW YORK,11952 MODULE(W) 400 PH:(631)779 7993 MODULE PTC(W) 376.70 NOTE: services@e2sys.com MODULE Isc(A) 13.s5 REVENUE GRADE KWH PRODUCTION METER CERTIFIED TO ANSI C12.1-2008 OR ANSI C.12.20 Licence-ME-52689 STANDARDS. (MASTER ELECTRICIAN) Licence-HI-67461 MODULE Voc(V) 36.80 (SUFFOLK HOME IMPROVEMENT) MODULE Imp(A) 12.99 NOTE: MODULE Vmp(V) 3o.so 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. Solar Individual 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH Permit Package PROPER JUNCTION BOX AT EACH END PER 690.31A JOE CONSTANTIN-GUILD WIRE SCHEDULE STARTING ADJUSTMENT MAXIMUM STARTING TEMPERATURE 12.000KW Grid Tied CONDUCTOR AWG ALLOWABLE TEMPERATURE CURRENT CORRECTION FACTOR FOR ADJUSTED CURRENT RACEWAY MORE THAN 3 CONDUCTOR APPLIED TO Photovoltaic System # EQUIPMENT WIRE LOCATION WIRE APPLIED TO FACTOR CITY. SIZE AMPACITY RATING (°C) CONDUCTORS IN CONDUCTORS AMPACITY CONDUCTORS 310.15(B)(16) RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) IN RACEWAY MATTITUCKONY 1952 1 DC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 Rev Description Date 2 AC MICROINVERTER TO AC DISCONNECT EXTERIOR WALL 2 12 30 90° 12.10 0.96 1 28.80 15.13 A INITIAL DESIGN 3/23/2024 3 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 12.10 0.96 1 72 15.13 A.1 UPDATED DESIGN 3 /2024 A.2 UPDATED DESIGN 3/30/30I2024 4 AC MODULE TO MICROINVERTER ROOF/FREE-AIR 2 12 30 90° 13.85 0.96 1 28.80 17.31 OPPORTUNITY JOECONSTANTIN-GUILD PROJECT# 5 DC MICROINVERTER TO COMBINER ROOF/FREE-AIR 2 12 30 90° 12.10 0.96 1 28.80 15.13 DATE DRAWN 31 3/30/2024 -~\ 6 AC COMBINER TO AC DISCONNECT EXTERIOR WALL 3 8 55 90° 24.20 0.96 1 52.8 30.25 DRAWN BY ER � J� 7 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 75 90° 24.20 0.96 1 72 30.25 SHEET# PV-5.0 TITLE 8 AC ELECTRICAL SLID 9 AC MATERIAL LIST °� "Ewy � O MM// o ,�P� pE - - �� cG ELECTRICAL EQUIPMENTS { D � C) — QTY. PART TYPE PART NUMBER DESCRIPTION 2� 099128 30 MODULE CS6R-40OMS-HL CANADIAN SOLAR CS6R-40OMS-HL Fa 4 CTRIGPY 30 MICROINVERTER IQ8PLUS-72-2-US ENPHASE IQ8PLUS-72-2-US ARO SS1oNP� 1 COMBINER X2-1 Q-AM 1-240-4/4C ENPHASE COMBINER BOXX2-IQ-AM1-240-4/4C STAMPED03/29/2024 2 AC DISCONNECT D322NRB 60A RATED 240VAC NEMA 311 UL LISTED THESE DRAWINGS ARE SUBJECTTO - COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS 4 TAP CONNECTORS IPCTAP IPC INSULATION PIERCING CONNECTORS EXPRESSLY FORBIDDEN WITHOUTPRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. . Current Rene%rables ' Engineering CURRENT RENEWABLES ENGINEERING INC. 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)-405-1733 WWW.CRENG.CO BREAKER / FUSES CONTRACTOR INFO QTY. PART TYPE PART NUMBER DESCRIPTION 2 BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) im Is 1 FUSES 40A FUSES GENERAL40A FUSES [2SYS9 1 FUSES 20A FUSES GENERAL 20A FUSES ELEMENT ENERGY LLC- 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 RACKING (SUFFOLK HOME IMPROVEMENT) QTY. PART TYPE PART NUMBER DESCRIPTION Solar Individual 12 RAILS & SPLICES XR-100-168A XR100, RAIL 168" BLACK Permit Package 6 RAILS &SPLICES XR100-BOSS-01-M1 BONDED SPLICE, XR100 JOE CONSTANTIN-GUILD 42 CLAMPS & GROUNDING UFO-CL-01-Al UNIVERSAL MODULE CLAMP, BLACK 36 CLAMPS & GROUNDING UFO-STP-35MM-M1 STOPPER SLEEVE, 35MM, MILL Photovoltaic Grid Tied 9 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE Photovoltaic System 400 LEGION AVE, 84 ATTACHMENTS QM-HUG-01-M1 HALO ULTRAGRIP, MILL MA-MTUCK,NY 1952 84 ATTACHMENTS HW-RD1430-01-M1 RD STRUCTURAL SCREW, 3.OL Rev Description Date 84 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE A INITIAL DESIGN 3/232024 Al UPDATED DESIGN 3127/2024 A2 UPDATED DESIGN 313012024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3130/2024 �l DRAWN BY E.R SHEET# PV-6.0 TITLE BOM � OF NEWk �P M `9 O 00E �'� �� CG r g D W — 2 099128 PHOTOVOLTAIC SYSTEMZ 'EQUIPPED WITH RAPID SHUTDOWN! CTRt ASStONP�' 690.12 STAMPED 03/29l2024 THESE DRAWINGS ARE SUBJECT TO _.. COPYRIGHT PROTECTION BY US LAW. — REPRODUCTION IN ANY FORM IS L TURN RAPID PV SYSTEM AC DISCONNECT WRITTEN APPROVAL FROM CUR ENTIOR RENEWABLES ENGINEERING INC. SHUTDOWN SWITCH TO RATED OUTPUT CURRENTe " MPS THE "OFF" POSITION TO AC •■ •■ • • Current SHUT DOWN PV SYSTEM _ ne� rle 690.14,690.15,690.54 ^� AND REDUCE SHOCK WARNING Engineering HAZARD IN THE ARRAY PM DUAL POWER SOURCES CURRENT RENEWABLES 690.56(C)(1)(B) ENGINEERING INC. • , • - - • • • ° 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 RATED ° , ° OUTPUT ! CURRENT - • 1 A ■ PHONE:(951)-405-1733 WWW.CRENG.CO rAC NORMALQPERATING,VOLTAGE • CONTRACTOR INFO 690.54 — — OPTIONAL SOLAR LOAD CENTER ARRAY EP-SYS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, JIB NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 . - L — (MASTER ELECTRICIAN) Licence-HI-67461 INVE■ - • - • • (SUFFOLK HOME IMPROVEMENT) 1• • • ° I NEC 690.31(G)(3)&(4),CRC R324.7 Solar Individual ® ■ .ENT DEVICE Permit Package (UNLESS BUSBAR IS FULLY RATED) L - 705.12(D)(2) PHOTOVOLTAIC POW,ER • ■ JOE CONSTANTIN-GUILD EVERY 10'ON CONDUIT AND ENCLOSURES PhotKW Grid Tied Photovvoltaic System NOTES. 400 LEGION AVE, MATTITUCK,NY 11952 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS Rev Description Date SHOWN HEREON. A INITIAL DESIGN 3f23/2024 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.1 UPDATED DESIGN 3127l2024 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR A.2 UPDATED DESIGN 3I30l2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. OPPORTUNITY IOE CONSTANTIN-GUILD B. RED BACKGROUND COLOR WHITE TEXT AND LINE PROJECT# NA WORK. DATE DRAWN 3130/2024 C. AERIAL FONT. DRAWN BY E.R 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN SHEET# PV-7.0 THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BE TITLE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. ��pF NEl1'YO� MqN/,p r D W 099128 2 CTRIr- ARO Ss%oNP� CAUTION STAMPED 03/29/2024 REMOTELY LOCATED DISCONNECT SWITCH AND METER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current Renewa- ies Engineering g 9 CURRENT RENEWABLES PV ARRAY ENGINEERING INC. L1J 1760 CHICAGO AVE SUITE SUB PANEL Q RIVERSIDE 507 PHONE:(95 -40S7733 AC DISCONNECT z WWW.CRENG.CO 0 CONTRACTORINFO U-1 0 MAIN SERVICE PANEL C�SYSD UTILITY METER AC DISCONNECT ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATUTUCK, COMBINER NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) Solar Individual Permit Package PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL JOE CONSTANTIN-GUILD PANEL IS AC DISCONNECT PER NEC690.17 12.000KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23/2024 I A.1 UPDATED DESIGN 3/27/2024 A.2 UPDATED DESIGN 3/30/2024 OPPORTUNITY JOECONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/30/2024 DRAWN SY E.R '\ SHEET# PV-7.1 TITLE PLACARD 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 MICROINVERTER CHART 1 2 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3 0�1710001-! Current Reneuvables Engineering FE CURRENT RENEWABLES ENGINEERING INC. 4 1760 CHICAGO AVE SUITE J-13,RIVERSIDE CA 92507 PHONE:(951)405-1733 W W W.CRENG.CO CONTRACTOR INFO MSP B L^ 5d ® � E2SYSS ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, 6 NEW YORK,11952 PH:(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.000KW Grid Tied 8 Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 31232024 9 A.1 UPDATED DESIGN 3127/2024 A2 UPDATED DESIGN 3I302024 OPPORTUNITY IOECONSTANTIN-GUILD PROJECT# NA _ DATE DRAWN 31302024 DRAWN BY E.R SHEET# PV-8.0 10 TITLE MICROINVERTER CHART SAFETY PLAN MARK UP KEY INSTRUCTIONS: _ COMBINER THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM Is 1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET. AC AC DISCONNECT EXPRESSLY FORBIDDEN WITHOUT PRIOR 2.SAFETY PLAN MUST BE MARKED BEFORE JOB WRITTEN APPROVAL FROM CURRENT STARTS AS PART OF THE PRE-PLAN MSP MAIN SERVICE PANEL RENEWABLES ENGINEERING INC. 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE &MAKE NOTES ON THE JHA SHEET UTILITY METER Current IN CASE OF EMERGENC0-ftRenewabies OP PERMANENT ANCHOREngineering ! g NEAREST HOSPITAL OR OCCUPATIONAUINDUSTRIAL CLINIC JB JUNCTION BOX CURRENT RENEWABLES NAME: TO TEMPORARY ANCHOR 1760 ENGINEERING CHCAGGO AVE SUITE J-13,RIVERSIDE CA 92507 ADDRESS: IL INSTALLER LADDER PWWWCRENG.001733 SAFETY COACH CONTACT INFORMATION STUB-OUT CONTRACTOR INFO ELI NAME: ADDRESS: ® SKYLIGHT NO LADDER ACCESS (STEEP GRADE 01 ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE OOR GROUND LEVEL OBSTRUCTIONS) E2SYS8' SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR RESTRICTED ACCESS WORKING SAFELY. ELEMENT ENERGY LLC. CONDUIT 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 NAME SIGNATURE Gas GAS SHUT OFF PH:(631)779 7993 services@e2sys.com Licence-ME-526B9 20 WATER SHUT OFF (MASTER ELECTRICIAN) Licence-HI-67461 SERVICE DROP (SUFFOLK HOME IMPROVEMENT) 7 O POWER LINES Solar Individual Permit Package JOE CONSTANTIN-GUILD 12.000KW Grid Tied Photovoltaic System 400 LEGION AVE, MATTITUCK,NY 11952 Rev Description Date A INITIAL DESIGN 3/23r2024 DATE: TIME: All UPDATED DESIGN 312712024 A.2 UPDATED DESIGN 313012024 OPPORTUNITY JOE CONSTANTINGUILD PROJECT# NA DATE DRAWN 3I30/2D24 \I DRAWN BY E.R SHEET# PV-9.0 TITLE SAFETY PLAN JOB HAZARD ANALYSIS Crew leader to fill out all sections below,hold a pre-job safety meeting with all personnel,and upload this completed document and the Safety Plan to Site Capture Ladder Access Public Protection Weather and Environment Restroom facilities Ladders must be inspected before each use. The safety of the Client and the Public must be maintained at all The site supervisor shall forecast the weather conditions at the Employees shall have access to restroom facilities with Extension ladders must be set up on a fine and level surface at times. job site,prior to crew arrival,in order to mitigate any hazards hand-washing stations.Use of onsite restroom is at the client's a 4-to-1 rise to run angle(or 75 degrees)and the top must be • The Client and the Public shall be prevented from entering the associated with inclement weather(heat,cold,wind,rain,etc.) discretion(location is annotated below).If client does not give THESE DRAWINGS ARE SUBJECT secured to the structure.Extension style ladders placed on work zone through the use of barriers and/or signage,as • The site supervisor will utilized a portable wind meter permission,location of suitable restroom facilities with COPYRIGHT PROTECTION R IS LAW. REPRODUCTION IN ANY FORM S uneven,loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions,by hand-washing stations offsite will be provided.The onsite EXPRESSLY FORBIDDEN WITHOUT PRIOR base firmly anchored or lashed so the base will not slip out. • Company,Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to WRITTEN APPROVAL FROM CURRENT • Extension ladders must la used with walk-through devices or falling objects. rooftop)prior to work start,at midday and prior to solar panel ensure all employees have access at an point. RENEWABLES ENGINEERING INC. ladder must extend 36"above the stepping off point. • Pets(including dogs)shall be secured by their owners prior to staging on a roof. the ladd • Restroom facilities will be(circle one):onsite-Offsite • theA-f ameladd ladders must only be climbed with the ladder spreader work start. • Elevated work involving the moving or maneuvering of solar If Offsite,add location name and address: bars locked in the open position;A-frame ladders shall not be The client should not leave pets,family members,or others in panels shall cease at 25mph(sustained wind)until wind Current climbed while in the closed position(ex,closed and used while the charge or care of Employees,Contractors,or Temporary subsides. Incident Reporting Procedure f leaned against a structure). Workers. Forecasted weather maximum temp(degrees F: Contact your Site Supervisor s'K Reneares Name: • Additional notes: Crew leader responsible for communication with the client: "F") Engineering Mobile Equipment Client and public is excluded from work area by barricades(N/A, • Only Qualified operators will operate equipment;operators must Yes, No): Heat Related Illness Prevention Phone: CURRENTNG IINABLES Employees shall have access to potable drinking water that is ENGINEERING INC. maintain a certification on their person for the equipment being 1760 CHICAGO AVE SUITE operated. Traininq and Pre-Job Safety Briefing fresh,pure,and suitably cool.The water shall be located as • Contact your Manager J-13,RIVERSIDE CA 92507 • Type(s)of mobile equipment(Type/Make/Model): • All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working. PHONE:W W W.CRENG.05-1733 NG.CO hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name: • Qualified operator(s): briefing,and their signature indicates awareness of site the work shift to provide at least one quart per employee per CONTRACTOR INFO conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift.Employees may begin the Phone: Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location • Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to Contact your Site Supervisor hazard to client,personnel or public.Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour.The roof will be physically P 9 protect from failing or sliding off. frequent drinking of water shall be encouraged. Name: El • Crew member(name/title): •Shade shall be present when temperature exceeds 80 degrees g Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds_ Phone: E2SYSS • A site-specific plan for fall prevention and protection is required Crew member(name/title): 80 degrees Fahrenheit,employees shall have and maintain one prior to starting work and must remain onsite at all times until or more areas with shade at all times. With:Your full name,phone number,office location,brief description ELEMENT ENERGY LLC. work is complete;a fall rescue plan must be outlined and Crew member(name/title): New employees must be acclimatized.New employees will be of what happen and when. 7470 SOUND AVENUE,MATTITUCK, discussed among the crew prior to work start. monitored by their Crew Leader(site supervisor)for the first two NEW YORK,11952 • First-person-Up(FPU)must install their anchor and conned Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE PH:(631)779 7993 before any other task,including installing other anchors.The Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets) services@e2sys.com Last-Person-Down(LPD)must be the only person on a roof • Crew member(name/title): scheduled breaks during each shift.Employees must take Licence-ME -52689(MASTER ELECTRICIAN) uninstallin fall protection. cool-down breaks in the shade any time they feel the need to do • FPCP(name and title): Airborne Contaminants: so to protect them from overheating.Supervisors are Licence-HI Define the Hazard: Method/steps to prevent incident: • Asbestos-containing(Transite)piping(ACP)-DO not disturb REQUIRED to allow employees any break period they need (sUFFDLK HOME IMPROVEMENT) FPU and LPD(name and title): (move,drill,cut fracture,etc.) during high heat conditions. • Asbestos-containing thermal insulation(ACI)and Cool Vests are encouraged for all employees at all times during Solar Individual Electrical Safety Asbestos-containing duct wrapping(ACW)-do not disturb,no periods of high heat. Permit Package • The Electrical Qualified Person(EQP)is required onsite to attic or crawlspace access is allowed if work to be performed Identify the location of the closet OccupationaVIndustrial Clinic Define the Hazard: Method/steps to prevent incident: perform electrical work. could cause exposure to personnel,client or public. or Hospital in case a crew member becomes ill. JOE CONSTANTIN-GUILD • All electrical work will be performed with equipment in an electrically safe condition(de-energized)unless approval has If yes,list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for been granted prior to work. all employees on site? 12.000KW Grid Tied If offsite(l replenish is necessary,where will you go to replenish • Service drops and overhead electrical hazards will be Define the Hazard: Method/steps to prevent incident: Photovoltaic System indentified and protected from contact as neccessa water(location/address): EQP(name and tile): • Who will replenish the drinking water(name): 400 LEGION MATTITUCK,NY 11952 Define the Hazard: Method/steps to prevent incident: Rev Description Date A INITIAL DESIGN &23=24 A.1 UPDATED DESIGN 3/2712024 A.2 UPDATED DESIGN 31302024 OPPORTUNITY JOE CONSTANTIN-GUILD PROJECT# NA DATE DRAWN 3/3012024 ~ } DRAWN BY ER SHEET# PV-10.D TITLE SAFETY PLAN CS6R-40OMS-HL/I-V CURVES w- - ENGINEERING DRAWING(mm) A =* `r CanadeanSalar _- Rear Vie Frame Cross Section A-A „p------ 14 w 12 12 THESE DRAWINGS ARE SUBJECT TO 6�5 - - ,p .. _ _ t0i _.. - 35 COPYRIGHT PROTECTION BY US LAW �I REPRODUCTION IN ANY FORM IS 64 EXPRESSLY FORBIDDEN WITHOUT PRIOR M g 2 WRITTEN APPROVAL FROM CURRENT s 6 _____- RENEWABLES ENGINEERING INC. -- - .-.. S a 4 - - : Mount ole z � 2 - Current Mounting H 1 I I 5 10 Is 20 25 30 35 40 45 50 55 60 5 10 15 ZD 25 30 35 40 45 50 55 60 Renewables 5,r■ Engineering 25=C- ■ goo wim 6W whir y5 1130 � a00 Wrm, 65°C CURRENT RENEWABLES �u^■ (G� R [F 200wr v ENGINEERING INC. ALL BLACK MONO PERC 1760 CRIVERSIDE C SUITE ® 9 p® q �A® ELECTRICAL DATA I STC* MECHANICAL DATA PHONE: 1)-405-1733 7 380 V� - 405 YY CS6R-380/385/390/395/400/405MS-HL Specification Data WWW.CRENG:CO CS6R-3�0 335 390 395 400 405 fVdS-Ff L Nominal Max.Power(Pmax) 380 W 385 W 390 W 395 W 400 W 405 W Cell Type Mono-crystalline CONTRACTOR INFO Opt.Operating Voltage(Vmp)30.0 V 30.2 V 30A V 30.6 V 30.8 V 31.0 V Cell Arrangement 108[2 X(9 X 6)] Opt.Operating Current(Imp)12.69 A 12.77 A 12.84 A 12.91 A 12.99 A 13.07 A Dimensions 1722 x 1134 x 35 mm g Industry Leading Product Warranty on Materials Open Circuit Voltage(Voc) 36.0 V 36.2 V 36.4 V 36.6 V 36.8 V 37.0 V (67.8 x 44.6 x 1.36 in) _ MORE POWER Years and Workmanship* Short Circuit Current(Isc) 13.55 A 13.63 A 13.70 A 13.77 A 13.85 A 13.93 A Weight 22.4 kg(49.4 Ibs) Module Efficiency 19.5% 19.7% 20.0% 20.2% 20.5% 20.7% Front Cover 3.2 mm tempered glass with anti-ref- lective coating Module power up to 405 W Operating Temperature -40°C-+85°C Frame Anodized aluminium alloy, C�SYS0 4Q5 V1z Module efficiency up to 20.7% Max.System Volta a 1000V IEC/UL) 25 t Linear Power Performance Warranty* y g ( J-Box IP68,3 bypass diodes I fi years Module Fire Performance or 2(UL 617301000V) Cable 4 mm'(IEC),12 AWG(UL) or CLA55 C(IEC 61730) ELEMENT ENERGY LLC. Lower LCOE&system cost 11 year power degradation no more than 2% Max.Se 25 A -- Connector T6,MC4,MC4 EV02 or MC4 EVOZA 7470 SOUND AVENUE,MATTm)CK, ries Fuse Rating NEW Y Subsequent annual power degradation no more than 0.55% Application Classification Class _ Cable Length 1550mm(61.O in)(+)/1100mm(433 in)(-)* PH:(631)779 9 799793 *Subject to the terms and conditions contained in the applicable Canadian Solar Limited Power Tolerance 0-+10 W pncluding Connector) services@e2sys.com Comprehensive LID mitigation warranty Statement.Aiso this 25year limited product warranty is available only for prod- Licence-ME-52689 �R p g ucts installed and operating on residential rooftops In certain regions. *Under Standard Test conditions(sTc)of Irradiance of 1000 W/m1,spectrum AM 15 and cell tempe. Per Pallet 30 pieces L+ �) ! MASTER technology,up to 50%lower degradation .........................................................................................................' ........... rature of2vC. Per Container(40'HQ)780 pieces ( F( ELECTRICIAN - - )E*For detailed information,please contatiyour local Canadian Solarsales and Licence HI 67461 MANAGEMENT SYSTEM CERTIFICATES* technical representatives. SU FOLK HOME IMPROVEMENT) ISO 9001:2015/Quality management system 8Better shadingtolerance ISO 14001:2015/Standards for environmental management system 150 45001:2018 1 International standards for occupational health&safety ELECTRICAL DATA NMOT* TEMPERATURE CHARACTERISTICS Solar Individual PRODUCT CERTIFICATES* CS6R-380/385/390/395/400/405MS-HL Permit Package MORE RELIABLE IEC 61215 IEC 61730( Nominal Max.Power(Pmax) 284 W 288 W 291 W 295 W 299 W 303 W Specification Data CEC listed U5 California)//FSEC(US Florida) Opt.Operating Voltage(Vmp)28.1 V 28.3 V 28.4 V 28.6 V 28.8 V 29.0 V Temperature Coefficien t(Pmax) -0.34%/°C JO E CONSTANTI N-GUILD UL 61730/IEC 617011 IEC 62716 Temperature Coefficient(Voc) -0.26%/°C Take-e-way Opt.Operating Current(Imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A P Minimizes micro-crack impacts L = Open Circuit Voltage(Voc) 33.9 V 34.1 V 34.2 V 34A V 34.6 V 34.7 V Temperature Coefficient(Isc) 0.05%/°C Short Circuit Current(Isc) 10.91 A 10.98 A 11.05 A 11.11 A 11.17 A 11.23 A Nominal Module Operating Temperature 42 t 3°C 12t Grid Tied .000KW +The specific certificates applicable to different module types and markets will vary, *Under Nominal Module Operating Temperature(NMOT),Irradiance of 800 W/m'•spectrum AM 1.5, PI I OtOVOIta IC System Heavy snow load up to 8100 Pa, and therefore not all of the certifications listed herein will simultaneously apply to the ambient temperature 20°C,wind speed 1 m/s. �r�c products you order or use.Please contactyour local Canadian Solar sales represemadve PARTNER SECTION ® wind load up to 5000 Pa* to confirm the specific ceNficatesavailable for your Productand applicable lntheregions ..................................................................................................................: 4OO LEGION AVE, In which the products will be used. MATTITUCK NY 11952 ............................................................................................................................... CSI SOLAR(USA)CO.,LTD.is committed to providing high quality Rev Description Date solar photovoltaic modules,solar energy and battery storage solutions to A INITIAL DESIGN 3123/2024 customers.The company was recognized as the No.1 module supplierfor •The specifications and key features contained In this datasheet may deviate slightly from our actual A.1 UPDATED DESIGN 3/27I2024 quality and performancelprice ratio In the IHS Module Customerinsight produces due to the on-going Innovation and product enhancement.CSI Solar Co.,Ltd.reserves the SUN Over the 20 ors,it has successful) delivered over 70 GIN right to make necessary adjustment to the Information described herein at any time without further UPDATED DESIGN 3/30/2024 Survey. past Ye Ynotice. For detailed information,please refer to the Installation Manual. Of premium-quality solar modules across the World. Please be kindly advised that PV modules should be handled and Installed by qualified people who OPPORTUNITY JOE CONSTANTIN-GUILD have professional skills and please carefully read the safety and Installation instructions before using PROJECT# NA .................................................................................................................................................................................................................................................................. our PV modules. ` ................................i �. :.................................................................................. CSISOLAR(USA)CO.,LTD. ................................................................................................. .......................g............................ ...........................................................................................J IDATEDRAWN 3�302D24 ! '� ER 1350 Treat Blvd.Suite 500,Walnut Creek,CA 94598,USA www.csisolar.com/na service.ca@csisolar.comRAWN BY PV_ ( � CSI SOLAR(USA)CO.,LTD. AugAu 2022 All rights reserved PV Module Product Datasheet v1.1 C25_F23 1_NA SHEET# PV-t 1.0 TITLE MODULE SPEC 1 ENPHASEa IQ8 and IQ8+ Microinverters Commonly used module pairings' W 235-350 235-440 To meet compatibility,PV modules must be within maximum input DC voltage and maximum module Ic listed below. Module compatibility - Module compatibility can be checked at https-//enphase.cominstallers/microinverters/calculator MPPT voltage range V 27-37' 27-45 THESE DRAWINGS ARE SUBJECT TO 18-48 Operating range V 16-58 COPYRIGHT PROTECTION BY US LAW. 22/48 22/58 REPRODUCTION IN ANY FORM IS Minimum/Maximum start voltage V .___._.__.- EXPRESSLY FORBIDDEN WITHOUT PRIOR Maximum input DC voltage V 50 60 WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Maximum continuous input DC current A 10 12 Maximum input DC short-circuit current A 25 Maximum module Is A 20 Current Overvoltage class DC port — II _ — - eneviablss t5� DC port backfeed current mA 0 Engineering PV array configuration — 1.1 ungrounded array,no additional DC side protection required;AC side protection requires maximum 20 A per branch circuit CURRENT RENEWABLES ___-_ -___-__,_—_-- 300 ENGINEERING INC. ---'` --'`------- ----- -—--------------- -------- -------------—------- - Peak output Power VA 245 1760 CHICAGO AVE SUITE J-13,RIVERSIDE Maximum continuous output power VA 240 290 PHONE:(951)-0OS-1 92507 -1733 Nominal grid voltage(L-L) v 240,split-phase(L-L),180' WWW.CRENG.CO -------- IQ8and IQ8+ Microinverters Easy to install Minimum and Maximum grid voltage' V 211-264 1.21 CONTRACTORINF • Lightweight and compact with plug- Maximum continuous output current A_ 1.0 - -_ Our newest IQ8 Microinverters are the industry's first microgrid-forming,software-defined and-play connectors Nominal frequency Hz 60 microinverters with split-phase power conversion capability to convert DC power to AC Power line communication(PLC) 47-68 power efficiently.The brain of the semiconductor-based microinverter is our proprietary Extended frequency range Hz between components - -----'----------------- - a 21 M ------------ application-specific integrated circuit(ASIC),which enables the microinverter to operate in AC short-circuit fault current over grid-tied or off-grid modes.This chip is built using advanced 55-nm technology with high-speed Faster installation with simple two-wire Arms 2 C 2 SYSI three cycles digital logic and has superfast response times to changing loads and grid events,alleviating cabling constraints on battery sizing for home energy systems. Maximum units per 20 A(L-L)branch _ 76 13 — High productivity and reliability c'vcuits `6 ELEMENT ENERGY LLC. Total harmonic distortion % 7470 SOUND AVENUE,MATTITUCK, Produce power even when the grid is NEW YORK,11952 - - Overvoltage class AC port - -_- -- III -__._---__-_-._.__.__.._ PH 63 779 7993 down` -------'---'- ------'--------------'--' ' More than one million cumulative hours AC port backfeed current -mA 30 services@e2sys.com - of testing -----i J---------_— - --- -- -- - ----- - -- Licence-ME-52689 Power factor setting to Class 11 double-insulated enclosure (MASTER ELECTRICIAN) 0.85 lead g...0.85 g9 9 - - y Grid-tied power factor(adjustable) — in la In Licence HI 67461 Part of the Enphase Energy System, IQ8 Series Microinverters redefine Optimized for the latest high-powered % 97.7 (SUFFOLK HOME IMPROVEMENT) PV modules Peak efficiency _ _ I08 Series Microinverters integrate with the reliability standards with more than one 25 IQ Battery,IQ Gateway,and the million cumulative hours of power-on 'CEC weighted efficiency % - 97 Solar Individual EnphaseApmonitoringandanalysis testing,enabling an industry-leading Microgrid-forming Nighttime power consumption MIN software- limited warranty of up to25years. • Compliant with the latest advanced Permit Package grid support" Ambient temperature range -40•C to 60'C(-40'F to 140'F) UILD Remote automatic updates for the 10 E CON STANTI N-G latest grid requirements Relative humidity range 4%to 100%condensing Configurable to support a wide range DC connector type MC4 _ - - ..._........_... .... 12 OOOKW Grid Tied '- of grid profiles Dimensions(H=W=D) 212mm(8.3 in)=175mm(6.9 In)=30.2mm(1.2in) Photovoltaic System Connect PV modules quickly and easily I08 Series Microinverters are UL Listed Meet CA Rule 21(UL 1741-SA)and IEEEQ1 Weight 1.08 kg(2.38lbs) to IQ8 Series Microinverters using the as PV rapid shutdown equipment and 1547:2018(UL 1741-SB 31 Ed.) Cooling Natural convection-nofans 400 LEGION AVE, included Q-DCC-2 adapter cable with conform with various regulations,when MATTITU CK,NY 11952 plug-and-play MC4 connectors. installed according to the manufacturer's NOTE: Approved for wet locations Yes instructions. • IQS Microinverters cannot be mixed with Pollution degree Rev Description I Date previous generations of Enphase microinverters (107 Series.106 Series,and so on)In the same Enclosure Class ll double-(nsulated,corrosion-resistant polymeric enclosure A INITIAL DESIGN 3123/20 system. A.1 UPDATED DESIGN 3/27/2024 Environmental category/UV exposure rating NEMA Type 6/Outdoor - IQ Gateway is required to change the default A.2 UPDATED DESIGN 1 3I30I2024 -Meets UL T741 only when installed with 10 System CaMmIler 2. grid profile at the time of Installation to meet ••106 OPPORTUNITY 10E rAN5TANTIN-GUILD and lc-upport split-phase,240 V installations only. local Authority Having Jurisdiction(AHJ) requirements, PROJECT# NA d)No enf wCep pC/pC rvrin 02023 ErchaseEnergy.All rights reserved Enphase,the a and CC logos,IQ and certain other marks fisted at r2)Namin l wneve range can be m tevc endW d, inn llrewlme bymh.&,Y. DRAWN 3I30/2024 httDaJ/enchme.com/trademark-usnoo-guidelines are trademarts of Enphase Energy.Ina.In the US and other coumnes Data subject to change. - 10BSP-12A-DSH-00207-2A-EN-US-2023-10-13 n)umne may w.x Rater rolocmreauiromamoto caloric morlumlwe ct mmranwneecxrbrenenmwur area 1085P-12A-DSH-00207-2.0-EN-US-2023-10- DRRAWNAWN 13 DATE 1 BY E.R SHEET# PV-11.1 TITLE MICROINVERTER - SPEC Enphase IQ Combiner 4/4C MODEL NUMBER Data S?1ee, IQ Combiner (X=IQrAM1-240-4) IQCombiner4withEnphase10 Gateway printed circuit board for imeg rated revenue grade PV production metering(ANSI Enphase Networking - C12.20+1-0.5%)and consumption monitoring(+%:2.5%k includes a silver solar shield to match the IQ Battery system and IQ system Controller 2 and to deflect heat. - 10 Combiner 4C(x-IQ-AM1-240-4C) IQ Combiner4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.51;)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-M7-06-SP-05),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. -- - - - - — (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in Enphase The Enphase IQ Combiner 4/4C with Enphase the installation area.)Includes a silver solar shield to match the10BatteryandIQSystemController and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) THESE DRAWINGS ARE SUBJECT TO p°�poi-p,p�••� �^ ®y IQ Gateway and integrated LTE-Ml Cell 'Ensemble Communications Kit _ -includes COMMS-'KIT-01 and CELLMODEM-Ml-06-SP-05 witfi 5_-year Sprint data plan for - COPYRIGHT PROTECTION BY US LAW. IQ Combiner p6.419 A�1 "'E/�C modem included only With IQ Combiner 4C) - COMMS-CELLMODEMddI-06 � .Erisemblesltes � REPRODUCTION IN ANY FORM IS CELLMODEMrM1-06-SP-05 "-4G based LTE-M1 cellular modem with 5-year.Sprint Baia plan EXPRESSLY FORBIDDEN WITHOUT PRIOR X-IQ-AM1-240-4 CELLMODEM-M7-06-AT05 -4GbasedLTE-M1'cellular modem with 5-year_AT&T data plan . WRITTEN APPROVAL FROM CURRENT Consolidates Interconnection equipment - - RENEWABLES ENGINEERING INC. Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. X-IQ-AM1-240-4C into a single enclosure and streamlines IQ BRK-10A-2-240V Circuit breaker,2 pole,IOA,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 microinverters and storage installations by BRK-20A-2P-240V Circuit breaker.2 pole,20A,Eaton BR220 Current BRK-15A-2P-24OV-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support providing a consistent,pre-wired solution for BRK-20A-2P-24OV-8 Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support e,' ewables EPLC-01 - Power line carrier(communication bridge pair),quantity-one pair a•� -- -- -- - - residential applications. It offers up to four XA-SOLARSHIELD-ES Replacement solar shield for lq Combiner 4/4C 0(11 Engineering ' 2-pole input circuits and Eaton BR series 7:• - ' ,•i p p 'XA-PLUG-1203, AccessoryrecepiacleforPodrerLineCarrferinlQCombiner414C(requiredforEPLC-Ot) J�EIJPHASE' ' CURRENT RENEWABLES busbar assembly. XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner 4/4C ENGINEERING INC. _ ,X_IQ-NA-HD-125A Hoiddown kit for Eaton circuit breaker with screws- 1760 CIVERSI AVE SUITE ELECTRICAL SPECIFICATIONS PHONE: HON :(951)OECA925o7 �J ,. - - PWWW.CRENG.001733 Yr�yli _ Smart 'Rating_ Contin.iousduty: . •- - -• CONTRACTOR INFO System voltage 120/240 VAC,60 Hz Includes IQ Gateway for communication and control Includes Enphase Mobile Connect cellular modem ;Eaton BRseries_5os6arraiing'r_ - �_� �725A _ a (CELLMODEM-MI-06-SP-05),included only with IQ Max.continuous current rating 65 Af 'r Combiner4C .{hdaz;conOnuous cun'errtiavng.(inpvifroritpV/siorage);.- 64 A. Id 0 _ _ _ _ __..__...__. .._.-...___..,._,----•---•------ e _ ;.; Includes solar shield to match Enphase IQ Battery Max.fuse/circuit rating(output) 90 A _ - _ - lT to fou?2=cie Eaton BR series Oisvi5uted Generation(DG)breakers only(not included) - C SYS . aesthetics and deflect heat 8rancF�cimuitsfsol'grand%orscorage).:, p p �- " Flexible networking supports su wi-Fi, PP tdax.total branch circuit breaker rating(input) BOA of distributed generation(45A with IQ Gateway breaker included i. Ethernet,or cellular ;,'" -.,'10A-or lsA raI.tio GE/Siehiens/Eaton included - 1 'Erivoybreaker_ _ _ - .. . C,• _ Optional AC receptacle available for PLC bridge ELEMENT ENERGY ATTI Production metering CT 200 A solid core pre-installed and wired to IQ Gateway 7470 SOUND AVENUE,MATTITUCK, Provides production metering and consumption - ,•' ! ConsvritptionmonitbringCT(CT-200-SPLIT) - .4 ifof20OAsplitcorecurcenttransfonners - - NEWYORK,11952 i 4 monitoring - ' ' PH:(631)779 7993 T 1 MECHANICAL DATA 2 _ f 'Dimensions(WxHxD) '- 37.5 x2l.. x 76.8 cm,{74,�75"•x'19.5•x 6.63•).Height(s 2106'(53`5 cm)with'mouming brackets. _ - ( - - ) Simple _ .._ ...- L services a sys co s.__:..•.._....____._._ ._._..r__-...-.,__.-_. ._. .._ .. HI 6R46AN Licence M MASTER ELECTRICIAN) I Weight - f 7.5 kg(16.5lbs) icence- j Centered mounting brackets support single Ambienttempe_raturerange d0°Cto+46°C(-40°xd 715°p) (SUFFOLK HOME IMPROVEMENT) q-•• t stud mounting Cooling Natural convection,plus heat shield t !a Supports bottom,back and side conduit entry _ Solar Individual Enclosure enviro Up t0 fou(2-pole branch CIfCU11S for 240 VAC nmerJtal rating Outdoor,NRTL-certified.;NEMA iy'pe 3R;potycarboriateconsituction - tt" .r ;,a�-+�- •�- --= -- - - - 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors T Permit Package plug-in breakers(not included) wire sizes •60 A breaker branch input:4 to 1/0 AWG copper conductors X-IQ-AM7-240-4C 60A total PV or Storage branch Circuits Main lug combined output:10 to 2/0 AWG copper conductors I, • Neutral and ground:14 to 1/0 copper conductors JOE CONSTANTIN-GUILD Always follow local code requirements for conductor sizing. • Reliable Altitude - To 2000 meters(6,560 feet) - 12.000KW Grid Tied Durable NRTL-certified NEMAtype 3R enclosure INTERNET CONNECTION OPTIONS PhOtOVOItaIC System r, IntegratedWi;Fi 802.11b/g/n Five-year limited warranty • Cellular CELLMODEM-Ml-06-SP-05,CELLMODElv1-Mt-06-AT-05(4G based LTE-M1 cellular modem).Note that an Enphase • Two years laborreifibOrSementpf0gramCOVefage Mobile ConnectcellularmodemisrequiredforallEnsembleinstallations. 400 LEGION AVE, ` included for both the IQ Combiner SKU's MATTITUCK,NY 11952 Ethernet,. - - -Optional,602.3,CatD-E(or Cai 6)UTP Ethernet cable(not'included) UL Iisted COMPLIANCE Rev Description Dale Comp1jance,IO.Combiner _ - - UL 7741.CAN/CSA C222 No.107.1,47 CFR.Part 15,Class B,ICES 003.. A INITIAL DESIGN 3/23/2024 Production metering>ANSi C72.20accuracy class 0.5(PV production) Consumption metering.accuracy class 2.5 A.1 UPDATED DESIGN 3127/2024 •` -L, ti'-`''' "' ••-"`__'" '- Compliance,IQ Gateway 3/30Y2024 UL 60607-7lCANCSA 22.2 No.61010-1 A.2 UPDATED DESIGN X-IQ-AMl-2 A pp OPPORTUNITY JOE CONSTANTIN-GUILD E N P H AS E. To learn more about Enphase offerings,visit enahase.com E N P H f1S E. PROJECT# NA To learn more about Enphase offerings,visit enohase.com G 2022 Enphase Energy.All rights reserved.Enphase,the Enphase Togo IC Combiner 4/4C,anc other names are trademarks of DATE DRAWN 3/30/2024 I ' Enphase Energy,Inc.Data s4eci to change 02-14-2022 DRAWN BY E.R � SHEET# PV-11.2 TITLE COMBINER SPEC AAk IRON RIDGE XR Rail° Family XR Rail° Family The XR Rails Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads,while minimizing material costs.Depending on your location,there is an XR Rail®to match. Solar is Not Always Sunny Over their lifetime,solar panels experience countless - THESE DRAWINGS ARE SUBJECT TO _ ,�;,,,,,. :,:n4^?""1� - --- COPYRIGHT PROTECTION BY US LAW. extreme Weather events.Not JUSt the WOfSt StOfmS In years, t�� ' "` REPRODUCTION IN ANY FORM IS 'r; °`" = EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT but the worst storms in 40 years.High winds capable of 1 _ - •#,m2^ „t ? :i;:•. L r';i := ="_ ripping panels from a roof,and snowfalls weighing RENEWABLES ENGINEERING INC.= _ "" enough to buckle a panel frame. ---' XR Rails®are the structural backbone ,. - .._...-------..------ .---------....__.._ _. . ------..._- .. -__-..-_ -...- - _.._-------.--._...- --...._ . .------..__.... preventing these results.They resist uplift, xR10 XR100 XR1000 ��. CurrentRenew_ protect against buckling and safely "_ p g ��f;� XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR100D is a heavyweight among -�`;` 0•'� and efficient) transfer loads into the vx Engineering y z rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle building structure-Their superior ` '''' w ., no snow.It achieves spans up to 6 feet, ( wind and snow conditions,while also extreme climates and spans up to 12 1 9 P ^'- 4 _ while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. e .;':''- ,. CURRENT RENEWABLES spanning capability requires fewer a":_r,. ., .. _ ENGINEERING INC. roof attachments, reducing the r �" 6'spanning capability 10'spanning capability I 12'spanning capability :' Moderate load capability Heavy load capability Extreme load capability 1760 RIVERSIDE AVE SUITE number of roof penetrations -`; '{ ~' ' ' J-13,RIVERSIDE CA 92507 P ¢ :. �,.,' Clear&black anodized finish Clear&black anodized finish Clear anodized finish PHONE:(951)405-1733 and the amount Of .;' r' �=�,.*w Internal splices available Internal splices available I Internal splices available www.cRENG.co .- �ti y t installation time. = = " F'; ` Fv CONTRACTOR INFO Rail Selection i ffi The table below was prepared in compliance with applicable engineering codes and standards.'Values area� n* based on the following criteria:ASCE 7-16,Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B,Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit IronRid e.com for detailed certification letters. r ELEMENT ENERGY LLC. 1 @ 7470 SOUND AVENUE,MATTITUCK, i c NEW YORK,11952 PH:(631)779 7993 Force-Stabilizing riUrVC l 90 f'* r services@e2sys.com j ,a,. ,, Licence-ME-52689 Sloped roofs generate both vertical and lateral 20 t;.. (MASTER ELECTRICIAN) forces on mounting rails which can cause them to None ` ' ` "` Licence-ELECTRICIAN) "*-z bend and twist.The curved shape of XR Rails® "XR1000 ' tr n h in both 140 XR10 �•XR1� -. -�; - `L Y S: '. (SUFFOLK HOME IMPROVEMENT) is specials designed to_increase s—e directions while resisting the twisting.This unique `n 160 feature ensures greater security during extreme � ! ... " `S - «���'. '' Solar Individual weather and a longer system lifetime. - a 90 ? <.`.; Permit Package 120 ... 1 20 I JOE CONSTANTIN-GUILD 140 _ 160 :; :;'`;'4° 12.000KW Grid Tied :. .. . ter. , 90 Photovoltaic System i 30 " .'l'.' 400 LEGION AVE, 160 i .� ` " J MATTITUCK,NY 11952 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 XR Railsb are IronRidgeo offers All XR Rails-are made of 6000-series i w, 40 _ : . Rev Description Date m alloy,then protected with an 160 ii i A INITIAL DESIGN 3/23/2024 compatible with ® @ a range of tilt leg aluminum a oy, p , - FlashFooY'and options for flat anodized finish.Anodizing prevents surface t A.1 UPDATED DESIGN 3/27I2024 other pitched roof roof mounting and structural corrosion,while also providing �� 80 160 , attachments. applications. a more attractive appearance. _ -- *- = ^@ A.2 UPDATED DESIGN 3/30I2024 120 OPPORTUNITY JOE CONSTANTIN-GUILD -- - _ _ - - - - - - - - - -- ------------------- ---- - - ----------- - -- ---- - - - d 'Table is meant to l>E a simplified span chart for conveying oeneral rail capabilities.US--a PROJECT# NA -- --' j::�L760 _approved certification letters for actual design guidance. _ DATE DRAWN 3/30/2024 DRAWN BY E.R _:,, - _ •� d SHEET# PV-11.3 TITLE RAIL SPEC A-Ins, IRON RIDGE LIICkMount` G Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves When integrating with a home,solar attachments _ ---" '• THESE DRAWINGS ARE SUBJECT A :. :, - .� '': ,,` - ;' i' T•_'- COPYRIGHT PROTECTION BY US LAW. must be dependable for the lifetime of the rooftop. _ _ --,'_;,! > ?"�-`-'_ REPRODUCTION IN ANY FORM IS Due to recent innovations, many asphalt shingles :. " r EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT have bonded courses.A mount that protects without RENEWABLES ENGINEERING INC. the need to pry shingles can really speed things up. G� is here to respect roof. _ _ _ "" Current Halo UltraGrip (HU ) P _ _ ��� Q, i the _ *3-°'� �e encases � � - minu m barrier th at enca cast-aluminum I Hal o is a -Its es UltraGrip,our industrial-grade,foam-and-mastic f1 seal.This allows HUG to accelerate the installation Engineering process and provide the utmost in waterproofing - ... ® °. ° ludk?Ins;tall.the rest. CURRENT RENEWABLES protection. Give your roof a HUG." When yog °• ° ENGINEERING INC. •g •-°•a ° °• ® �crews to deck ° 1760 CHICAGO AVE SUITE IN r._..•-• - _ - - -- - J13,RIVERSIDE CA 92507" PHONE:(951)-405-1733 WWW.CRENG.CO ,z .`Multi-Tiered Waterproofing CONTRACTOR INFO ` -HUGQ utilizes a multi-tiered stack of cvmponerit§"to provide revolutionary Trusted Strength & Less Hassle waterproofing protection.The Halo cast- I atuinihum;raised perimeter foundation „ : Structural capacities of HUGS were reviewed in stii7ou . ,the:UftraGrip base—a foam- eanl3Sfidseal.combinationthat many load directions,with racking rail running I enfs waterantiusion by adhering cross-slope or up-slope in relation to roof pitch. seafhg`vnththe'shinglesurface. C SYS For further details,see the HUG certification t�--- Ha;c U4traGrip'"is part of the;OuickMount` letters for attaching to rafters and decking. ELEMENT ENERGY LLC. roduct tine. "y` 7470 SOUND AVENUE,MATTITUCK, NEW YORK,119s2 .:; IronRidge designed the HUG, in combination pH:(631)779 7993 with the RD Structural Screw to streamline services@e2sys.com p Seal Technology Licence-ME-s2eB9 UltraGri installs,Which means the following: (MASTER ELECTRICIAN) HUG UIVaGrip utilizes a State 0f art seal design that uses a unique:: '` Licence-H I-67461 foam-and-mastic combination,._7tie '` No prying shingles (SUFFOLK HOME IMPROVEMENT) foam-backed adhesive provides. No roof nail interference entirely new flashing system Yhi: conforms and adheres toevery;npoK ''25-VewWsrmrrty'; No pilot holes necessary Solar Individual and cranny of compositiort`Stimgt2s. Froquctguaranteed tr2e No sealant(in most cases) : .:; pa)-„g Permit Package filling gaps and shingle'step dviw{e °t impairing` Q` _ No butyl shims needed g -. (up to 1/8'in height). '`.-,•.- �� � •-- - -_------------------ i JOE CONSTANTIN-GUILD 12.000KW Grid Tied e rip. Loading Photovoltaic System .u_ - . _ 400LEGIONAVE, _ - MATTITU K Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUG to the roof rafters,the roof Rev Description Date HUG has been and certified for the UL 441 Section UL 2703 mechanical A INITIAL DESIGN 3/232024 • :•'. °;' deck,or both with our custom-engineered Jam,. RD(rafter-or-deck)Structural Screw.The RD tested and rated to compliance with 27"Rain Test"and and bonding A., UPDATED DESIGN 3127,2024 Triple Rated&Certified ` Structural Screw anchors HUG to the roof support 1004 Ibs of the International TAS 100(A)-95 requirements.See A.2 UPDATED DESIGN 3/30/2024 to Respect the Roof" with an EPDM sealing washer,completing uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual UL 2703,441(27) the stack of waterproofing barriers.See OPPORTUNITY JOE CONSTANTIN-GUILD Intertek TAS 100(A)-95 _ - __ _ _ __ backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. PROJECT# N® DATE DRAWN 31 3012024 QQ DRAWN eY E.R ` �e 2 123 'SHEET# PV-11.4 TITLE ATTACHMENT SPEC r 28357 Industrial Blvd. 28357 Industrial Blvd. Hayward,CA 94545 Hayward,CA 94545 AW ©w, I /"► 1-800-227-9523 I RON RI D/±E 1-800-227-9523 lronRidge.comAttn:Corey Geiger,COO,IronRidge Inc. The parameters and adjustments allowed in the span tables are defined as the following: Date:September r,2021 1. The Flush Mount System is designed as a Risk Category II structure as defined b ASCE 7-16 Table 1.5-1. THESE DRAWINGS ARE SUBJECT US A Re:Structural Certification and Span Tables for the IronRidge Flush Mount System y g g �' y COPYRIGHT PROTECTION R IS LAW. REPRODUCTION IN ANY FORM IS 2. Winds speed shall conform to ASCE 7-16 Fig.26.5-1 B(for Risk Category II)and applicable state&local EXPRESSLY FORBIDDEN WITHOUT PRIOR p WRITTEN APPROVAL FROM CURRENT This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The county/city amendments to the IBC. No special'wind topographic features are included and both topographic RENEWABLES ENGINEERING INC. contents of the letter shall be read in its entirety before applying to any project design.The Flush Mount System is a coefficient(Kt)and Wind ground elevation factor(Ke)are taken as 1.0. proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape 3. Snow load used in the span tables is the ground snow and shall conform to ASCE 7-16 Fig.7.2-1 and orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails ,�.. F - Current applicable state&local county/city amendments to the IBC.If the local jurisdiction specified snow load is in the �,.�.-;�, � n,,�� rJ cx �$ and secured to the rails with IronRidge mounting clamps-The XR Rails are side mounted to a selected roof format of a flat roof snow,it shall first be converted to a ground snow following the local building code/ attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion amendments before the application of the attached span tables-No special snow conditions are considered Engineering that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core including unbalanced,drifting,sliding,retention,or ponding snow.No rain-on-snow surcharge load is considered.The span tables do not apply to buildings which are intentionally kept below freezing,kept just above freezing,or unheated. CURRENT ING INC.SLEs components are shown in Exhibit EX-0015. ENGINEERING INC 1760 CHICAGO AVE SUITE The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: J-13.RIVERSIDE CA 92507 PHONE:(951)-405-1733 listed below,for the load conditions and Configurations tabulated in the attached span tables. WWW.CRENG.CO (a)For ground snow no greater than 42psf:S5:52.Og for Site Class A,B,C,&D. CONTRACTOR INFO ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures(ASCE 7-16) (b)For ground snow greater than 65psf:Ss s 1.0g for Site Class A,B,C,&D. 2018 International Building Code(IBC-2018) (c)For ground snow between 42 and 65psf:Ss:5 1.5g for Site Class A,B,C,&D. 2020 Building Code of New York State(BCNYS-2020,Published in November 2019) - 2015 Aluminum Design Manual(ADM-2015) 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in which the zones share the same External Pressure Coefficients(GCp).Roof zones comprising each group along 01 Report SEAOC(Structural Engineer Association of California)PV2-2017 Wind Design for Solar Arrays with each roof zone's size and location are depicted in Figures 2 and 3 below each span table. C2SYS9 The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for 6. The maximum rail cantilever length,measured fromthe rail end to the nearest attachment point,shall the respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones provided in be the lesser of the following two conditions:40/o of the allowable span provided for the respective load ELEMENT ENERGY LLC. &configuration condition from the span tables,or 36 7470 SOUND AVENUE,MATTITUCK, ASCE 7-16 for gable&hip roof profiles,and roof slopes of 8`to 45 The tabulated spans are applicable when the NEW YORK,11952 following conditions are met: 7. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over PH:(631)779 7993 sercom a minimum of three spans. Licence-ME-5 689 Licence-ME-52689 1. Span is the distance between two adjacent roof attachment points(measured at the center of the 8. No splices are allowed in the rail cantilever.For each XR splice type install per the following requirements: (MASTER ELECTRICIAN) Licence-HI-67461 attachment fastener). (SUFFOLK HOME IMPROVEMENT) a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans,or the outer 2!3 of end spans. 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system).Spans are calculated b) BOSS Splice can be installed at any location Within a span. Solar Individual based on 2 rail systems,and conservatively deemed acceptable for 3 rail systems. 9. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded.If Permit Package such conditions are encountered contact support@ironridge.com. 3. The underlying"roof slope,measured between the roof surface and horizontal plane,is B°to 450. JOE CONSTANTIN-GUILD 4. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured 12.000KW Grid Tied from grade,does not exceed 30 feet. Photovoltaic System 5. A clearance from the underside of the array to the roof surface of 2"minimum shall be provided and the 400 LEGION AVE, height of the array,the distance from the module top surface to the roof surface(defined as h2),shall not MATTITUCK,NY 11952 exceed 10 Rey Description I Dale A INITIAL DESIGN 3I M024 6. Module length and area shall not exceed the maximum values listed on the respective span tables. A.1 UPDATED DESIGN I 3/27/2024 A.2 UPDATED DESIGN I 3/30/2024 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush OPPORTUNITY JOE CONSTANTIN-GUILD Mount Installation Manual and other applicable standards for the general roof construction practice. PROJECT u NA _ DATE DRAWN 3/30/2024 i DRAWN 6Y E.R r ©202 I IronRidge,Inc. NY Flush Mount System Certification Letter-1 2021 IronRidge,Inc. NY Flush Mount System Certification Letter-2 SHEET# PV-11.5 TITLE CERTIFICATION 28357 Industrial Blvd. 28357 Industrial Blvd. Hayward,CA 94545 Hayward,-9 94545 I RON RI DV E IronRi ge.cor23 �� IRQNRIDGE 1-800-227-9523 IronRidge.com IronRidge.com 10. Systems using CAMO module clamps shall be installed with the following guidance: The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no a) For single module installations(orphan modules)using modules with a length greater than 67.5",CAMO consideration of the structural adequacy of the chosen roof attachments,PV modules,or the underlying roof supporting clamps shall not be installed in regions that experience ground snow loads of 70psf and greater.Such members.It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the scenarios are shown by asterisks in the applicable span tables. THESE DRAWINGS ARE SUBJECT TO module being used with aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. COPYRIGHT PROTECTION BY US LAW. b) CAMO will function within a module's design load ratings.Be sure the specific REPRODUCTION IN ANY FORM IS CAMO meets the dimensional requirements shown in the figure below and that the module selected is O 1 •O •O EXPRESSLY FORBIDDEN WITHOUT PRIOR suitable for the environmental conditions of a particular project. ��pF"NE�,y WRITTEN APPROVALIN FROM CURRENT Sincerely, __ RENEWABLES ENGINEERING INC. Y griG-X&. _ - ------- MOdule'Glass%Ce16 C" 15:45.16 �'^ Current Renewables _07'00' Engineering Fro me Compati]MTity — ------ - - CURRENT RENEWABLES X=1.2-2.2mm ENGINEERING INC. Y=15-40mm Gang Xuan,PE 1760 CHICAGO AVE SUITE RIVERSIDE J-13,RIVERSIDE CA 92507 Y { Senior Structural Engineer PHONE:(951)405-1733 ly-S X WWW.CRENG.CO —r CONTRACTORINFO Figure 1:CAMO Module Frame Dimensional Requirements Span values for Exposed and Edge module conditions,as defined below,are included in the attached span tables and shall be used when each condition exists. The maximum allowable span for Exposed or Edge Ann* modules shall be the lesser of the following two:(1)The span value for the Exposed or Edge module condition; i C SYS0 (2)The span value determined by site wind speed and ground snow load.Additionally,irrespective of the lesser span,the shaded cells for the Exposed and Edge module conditions which reflect the UFO clamp usage limitation detailed in note 9 of page 2 shall apply to the respective condition. ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 1. Exposed Module Conditions: services@e2sys.cos.com Licence-ME-52689 A module is defined as Exposed(per Section 29.4.4 of ASCE 7-16)if the distance from any of its free (MASTER ELECTRICIAN) Licence-HI-67461 edges(an edge with no connectivity to other modules)to its facing roof edge(such as eave,ridge,rake,Or (SUFFOLK HOME IMPROVEMENT) hip)is greater than 0.5h(h is ASCE defined building height)AND if the distance from its free edge to any other adjacent array or panel is greater than 4 feet. Solar Individual The allowable spans and Cantilever shall only be applied to the portion of rail directly under Exposed Permit Package Modules. JOE CONSTANT[N-GUILD 2. Edge Module conditions: 12.000KW Grid Tied A module is defined as an Edge Module when its distance from any side of the module to its facing Photovoltaic System perimeter roof edge(such as eave,ridge,rake,or hip)is less than 2 times the height of the array(2h2) 400 LEGION AVE, where h2 is measured from the roof surface to the top surface of the module. MATTITUCK,NY 11952 The allowable spans and cantilever shall only be applied to the portion of rail directly under Edge Modules. Rev I Description Date Additionally,if the roof edge is the eave or ridge,only the rail nearest to that roof edge shall be considered A INITIAL DESIGN 3/2312024 A.1 UPDATED DESIGN 3127/2024 for this span adjustment. A2 UPDATED DESIGN 3/30/2024 OPPORTUNITY JOE CONSTANTIN-GUILD NY Flush Mount System Certification Letter-4 PROJECT# NA 02021 IronRidge,Inc. NY Flush Mount System Certification Letter-3 ©2021 IronRidge,Inc. _ DATE DRAWN 3/30/2024 1 DRAWN BY I E.R \ SHEET# 1PV-11.6 TITLE CERTIFICATION