Loading...
HomeMy WebLinkAbout50626-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE h SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50626 Date: 5/6/2024 Permission is hereby granted to: KapetanakosVasilios ._........... . .... w�w..... .w�w__._........ _ _�w__..._..._w _� ..._w..__._. 215-11 85th Ave . .w_...............�w_................_......._ww.. ..A_ w.. ..._._ ....... . _..._ Hollis Hills NY 11427 To: Construct new single family dwelling as applied for, with SCHD approval. At premises located at: 520 Zena Rd, Mattituck SCTM #473889 _ .�ww__.......... ._�_w_....�.. .._.�w_...._....__ _... ._wwww..... Sec/Block/Lot# 106.-2-43.2 Pursuant to application dated -11/29/2023 and approved by the Building Inspector. To expire on 11/5/2025. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $2,332.50 CO -NEW DWELLING $100.00 Total: _...$2,432.50 Building Inspector 5 �w TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502hup ; x ;v; itolltta ,taµ� > t Date Received APPLICATION For Office Use Only PERMIT NO. Building Inspector: J f Applications and forms must be filled out In their entirety.incomplete ���1-� ' ''.'r.:§ applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed Date:9/21/2023 OWNER(S)OF PROPERTY: Name:Speonk Land Development LLC SCTM# 1000- 106.00-02.00-043.002 Project Address:520 Zena Rd, Mattituck, NY, 11952 Phone#:631-512-4522 Email:monumnetalproperty@yahoo.com Mailing Address:3080 Route 112 Suite B, Medford, NY, 11763 CONTACT PERSON: Name:Christopher F. Dwyer, Associate, LKMA Mailing Address:437 South Country Road, Brookhaven, NY, 11719 Phone#:631-286-8668 Email:cdwyer@Ikma.com DESIGN PROFESSIONAL INFORMATION Name:Robert A. Steele P.E., Executive Vice President, L.K. McLean Associate, P.C. Mailing Address:437 South Country Road, Brookhaven, NY, 11719 Phone M 631-286-8668 Email:cdwyer@Ikma.com CONTRACTOR INFORMATION: Name:Oasis at Mattituck Corp. Mailing Address:3080 Route 112 C, Medford, NY, 11763 Phond#:631-767-4807 Email: r@modernagehomebuilding.com DESCRIPTION OF PROPOSED CONSTRUCTION *New Structure ❑Addition OAlteration ❑Repair ODemolition ❑Other Estimated Cost of Project: Will the lot be re-graded? *Yes ❑No will excess fill be removed from premises? ®Y es ❑No 2 PROPERTY INFORMATION Existing use of property:Vacant Intended use of property: Singe Family Residence Zone or use district in which premises is situated: Are there any cZenants and restrictions with respect to R-40 this property? Yes ®No IF YES, PROVIDE A COPY. 11 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Christopher F. Dwyer Authorized Agent ❑Owner Signature of Applicant: Date. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Christopher F. Dwyer being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Agent (Contractor, Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. �� Sworn before me this p 2—day of � ,. -7) Notary Pul"i l rRISTIN ( a ) tA v� p UCH o 11 `9 c625n r rr ot Ini iE Suffolk County th� cants nth 48Au residing at 437 South Country Rd, Brookhaven NY, 11719 do hereby authorize , to apply on my behalf to the Town of Southold Building Department for approval as described herein. 9/26/2023 Owner's Signature Date Prin�Ow �SNme 2 3D, 6i �FOIKAWWATIEIK Scott A. Russell S SUPERVISOR 1W A,N A G 1E AW]ENT SOUTHOLD TOWN HALL-P.O.Box 1179 0 Town of Southold 53095 Main Road-SOUTHOLD,NEW YORK 11971 CHAPTER 236 - STORMWATER MANAGEMENT REFERRAL FORM .............. ( APPLICANT INFORMATION TO BE COMPLETED BY THE APPLICANT ONLY FOR PROPERTIES ONE ACRE IN AREA OR LARGER. ) APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) Date: NAME: Christopher F. Dwyer 9/26/2023 N�np . ......... cdwyer@lkma.com J, Contact Information: 1U`vlail&Telephnne Nwnhei) 631-286-8668 Pro ert Address / Location of Construction,Site: 520 Zena Rd, Mattituck, NY, 11952 S.C.T.M. 4: 000 tri�.t 106.00 02.00 043.002 ........... SecLion Block Lot rITi 1 70 BE COMPLETED BY SOUTHOLD TOWN ENGINEERING DEPARTMENT - - — — — — — — — — — — — — - - - - -,,S. Pernli� .5 ReguLlLed Area of Disturbance is less than I Acre. Cho S R Project does Not Discharge to Waters of the State. No S.PDE�. Permit is RecLwred Area of Disturbance is Greater than I Acre & Storm-water Runoff Discharges Directly to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit DIRECTLY From N.Y.S. D.E.C. Prior to issuance of a Building Permit— Area of Disturbance is Greater than I Acre & Storm-water Runoff Flow.,, Through Southold Town's MS4 Systems to Waters of the State of New York, THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permitj w__nE r I Dewar. Prior to Issuance of Builriinq Perrait- Date: Reviewed BY: 11 qM(-P-T0qnri,ri,,-,- qniq ,., L11AA LETTER OF TRANSMITTAL L. K. McLEAN ASSOCIATES, P.C. _ CONSULTING ENGINEERS DATE: 04/24/24NNNN PRO1 NO.: 23098 437 SOUTH COUNTRY ROAD ATT: To Whom It May Concern BROOKHAVEN, NEW YORK 11719 RE: 520 Zena Road,Mattituck SCTM#1000-106.00-02.00-043.002 TO: Town of Southold Building Department �WWWW 54371;Main Road -�- -�� Architectural Plans PO Box 1179 Southold,NY 11971 We are sending you Attached 0 Under separate cover via ..... . the following items: Shop Drawings Prints X Plans Samples Specifications Copy of Letter Change Order Other: Co ies Date No.Sheets Description 4 �4/24/2024wwM 6 _ Stam ed&Si ned Architectural Plans 24""x36"") p g C �..._._.��www_.....�w These are transmitted as checked below: For Approval Approved as Noted Resubmit Copies for Approval X ____. For Your Use Returned for Corrections Submit Copies for Distribution As Requested No Exception Taken Make Corrections as Noted For Review and Comment Other: For Bids Due Prints Returned After Loan to Us REMARKS: 16 4. 4W ..i_.,. g _.: Chr sttopher F. r, so 17vuye Asciate(Ruth.Agent) _� Copy To: LKMA File,Brooklyn Timber LLC ,i ned LICARA L. K. McLean Associates, D.P. C. ❖ 437 South Country Road • Brookhaven + New York • 11719 (631)286-8668 • FAX (631)286-6314 ❖ 25 Newbridge Road • Suite 212 • Hicksville • New York • 11801 https://www.lkma.com ROBERT A STEELE,P.E.PRESIDENT and CEO Associates JAMES L,DeKONING,P E,,VICE PRESIDENT STEVEN W.EISENBERG,P.E CHRISTOPHER F.DWYER,VICE PRESIDENT ANDREW B,SPEISER KEITH J,MASSERIA,P.E.,VICE PRESIDENT VINCENT CORRADO,P.E MATTHEW JEDLICKA,LEED AP,PRINCIPAL KEVIN J PETERMAN,P E. TAMARA STILLMAN,P.L.S.,PRINCIPAL-DIRECTOR OF SURVEY KARA M,O'NEILL,LISP,MBA CHRISTINE L,BELSON,MBA,SHRM-SCP,PRINCIPAL-CONTROLLER Town of Southold March 25,2024 Building Department 54375 Main Road, P.O. Box 11 „ Southold, NY, 11971 Re: 520 Zena Road,Mattituck, NY,11952 Letter Requesting Building Permit LKMA Project#:23098.000 SUM:1000-106.00-02.00-043.002 To Whom It May Concern: In order to obtain a building permit for a property located at 520 Zena Road, Mattituck, NY, 11952, we are submitting the following: • (1)Copy of SCDHS Approved Plans • (1)Signed Stromwater Management Plan • (1)Stormwater management referral form o (1)Original ResCheck, Manuals, HVAC loads,etc. a (4)Original Signed Sets of Architectural Drawings Thank you in advance for your consideration. Should you have any questions please do not hesitate to call me at (631)286-8668. Very truly yours, Christopher F. Dwyer,Vice President CFD:vc Enc(5) Cc: Speonk Land Development LLC w/enc. LKMA File Copy Established 1950 REWRate - Residential Energy Analysis and Rating Software v16.3.4 Build: New 'York Compliance Certificate Project Title: New Home 1000-106-2-43.2 Report Date 2024-02-27 Data Filename 2023_018 520 Zena Rd.P.CC.blg Energy Code 2018 IECC as amended in the 2020 New York State Energy Conservation Construction Code Permit# Location Riverhead, NY Construction Type Single-family detached Permit Date Heating Type Propane . � Glazing Area Percentage 12% Heating Degree Days 5294 HERS Index 59 Construction Site Owner/Agent Designer/Contractor HERS Rater 520 Zena Road Kapetanakos Modern Age Home Builders, LLC DAmaro Engineering Mattituck, NY 11952 520 Zena Road 3080 Route 112, Suite C Jerry DAmaro Mattituck, NY 11952 Medford, NY 11763 Certification#2614397 631-569-4513 631-878-7808 Building Information Conditioned Area (sq ft) 3632 Conditioned Volume (cubic ft) 38800 Insulated Shell Area (sq ft) 7160 ....,. _e,, ,,.w........... ........... The items below will be inspected for energy code certification. Any deviation from these specifications should be brought to the attention of the HERS Rater, as soon as possible to assure that the project will still comply with energy code requirements. Compliance (must pass either UA or Performance Path) Code Compliance Pass UA Path Pass Performance Path Pass Duct R-Value Pass Maximum Energy Cost($/yr) 4984 Maximum UA 395 Your Home Energy Cost($/yr) 4628 Your Home UA 378 Better Than Code (Perf) 7.1% Better Than Code (UA) 4.4% Gross Area Cavity Cont. Glazing or Door Assembly or Perimeter R-Value R-Value U-Factor UA Ceilings Roof 1: R-39 SPF SA 1226 39.0 0.0 43 Above-Grade Walls AG Wall 1: R-20 Batt+Rigid 2445 15.0 5.0 133 AG Wall 2: R-18 SPF+Rigid 312 13.0 5.0 18 Joist 1: Cond--- ambient 155 13.0 5.0 0 REM/Rate - Residential Energy Analysis and Rating Software v16.3.4 Build: 1013 This information does not constitute any warranty of energy costs or savings. ©1985-2022 NORESCO, Boulder, Colorado. REM/Rate - Residential Energy Analysis and Rating Software v16.3.4 Build: New York Compliance Certificate Gross Area Cavity Cont. Glazing or Door Assembly or Perimeter R-Value R-Value U-Factor UA Joist 2: Cond--- ambient 113 13.0 5.0 0 Joist 3: Cond--- ambient 23 13.0 0.0 0 Window 1: U:0.28, SHGC 0.31 DR 40 0.280 11 Window 2: U:0.30, SHGC:0.31 210 0.300 63 Window 3: U:0.28, SHGC 0.32PIC 32 0.280 9 Window 4: U:0.28, SHGC:0.25 15 0.280 4 Door 1: Fiberglass U-0.28 JD 34 0.280 0 Door 2: Fiberglass U-0.17 JD 20 0.170 0 Slab Floors On-Grade Perimeter 2: R-5 Under Slab 14 n/a 0.0 2 Basement Walls Wall 1: R-11 Blanket-8ft 1317 0.0 11.0 76 Watt 2: R-11 Blanket-loft-full 140 0.0 11.0 11 Window 5: U:0.30, SHGC:0.30 29 0.300 9 Door 22 0.220 0 Infiltration Htg: 3.00 Clg: 3.00 ACH50 Mechanical Equipment Heating: Fuel-fired air distribution, 64.0 kBtuh, 96.1 AFUE. Water Heating: Conventional, Prop, 0.72 EF. Cooling: Air conditioner, 33.2 kBtuh, 14.5 SEER. Required signatures vary depending upon state and or local codes, requirements and regulations. Check with your local building department to determine which signatures are required for your application. Builder or Authorized Employee I w. .certify that the home listed above shall be built to meet or exceed all requirements of the 2018 IECC as amended by the 2020 New York State Energy Conservation Construction Code and all current energy codes specific to the local jurisdiction in which the home is built. Name -Title Signature Date Rater I, Jerry D'Amaro of DAmaro Engineering, certify that the home listed above, as modeled meets or exceeds all requirements of the 2018 IECC as amended by the 2020 New York State Energy Conservation Construction Code and all current energy codes specific to the local jurisdiction in which the home is built. I I further attest that I am a certified Home Energy Rater and affiliated with a HERS Provider accredited by RESNET and adhering to the requirements of the Residential Energy Services Network RESNET Standards. REM/Rate- Residential Energy Analysis and Rating Software v16.3.4 Build: 1013 This information does not constitute any warranty of energy costs or savings. ©1985-2022 NORESCO, Boulder, Colorado. Page 2 of 3 REWRate - Residential Energy Analysis and Rating Software v16.3.4 Build: New York Complian er if"'calte W"Ui 4 , Name -Title Signatu Date REM/Rate- Residential Energy Analysis and Rating Software Y 1 63.4 Build: 1013 This information does not constitute any warranty of energy costs or savings. ©1985-2022 NORESCO, Boulder, Colorado. Page 3 of 3 Building Permit Checklist Permit M Date submitted: w. Date reviewed: Owner/Applicant... PropertySCTM: 1000- Address Pro ect _D ...... Parcel Size, arc P ramid, Zone, overage e: allowable % & SF. ZZ az total, 17 Single & Separate Principle Structure: Required Setbacks: Front Sides R e a r Lot,Coveragej�rnit . ............ . ...... .. ........ Corner Lot: ,,.,§econdar Proposed Setbacks: Front Lot Coverage_,_,. Corner Lot, Prir"a .._,�5 secondaryL. ry Accessory Structure: Accessory Use: Required Setbacks: Front Sides Rear Lot Coveraae Limit Proposed Setbacks: Front Sides Rear Lot Coverage Conforming Location? Size Height.......... Dormers PI mbin Waterfront: Water Body: Flood4one: Distance to Bluff: To Wetlands: Bulkhead: Contour: ........................ Trustees: date: Conditions: ........... ZBA: date: Conditions: SCHD 04 date: Bedrooms' ccessory� Planning- date: Conditions: 1111­111 ­1111­ . ............................ ............ .. ..........DEC: date: NJ Date: notes., Sq.ft. Calculations: foundation_ first floor porch�es. decks, second floor demo Total� Additional Notes,.,, .................. ........ ............... 3 8a s a 4-0 ----------------- 6pO-D � t IS1140 0 w Generated by REScheck-Web Software Compliance Certificate Project 2023 018 Aurora detached garage Energy Code: 2018 IECC Location: Mattituck, New Yorke ' ' Construction Type: Single-family Type:Project T e: New Construction r�i )� Orientation: ond tinned Floor Area: 3! s 270 deg. from North 632 ft2 C Glazing Area 11% t 17 Climate Zone: 4 (5331 HDD) ��� n" Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor 520 Zena Road Peter Jerome D'Amaro Mattituck, NY 11952 Modern Age Home Builders, LLC D'Amaro Engineering and 3080 Route 112 Surveying, P.C. Suite C 20 Mariposa Lane Medford, NY 11763 Manorville, NY 11949 631-569-4513 631-878-7808 peter@modernagehomebuilding.co jdamaro@optonline.net m Compliance: 1.0%Better Than Code S1ab­o n..graxle tiradeoffs are irno Iloirngeir considered in the UA or PerfoirMance ccirn piIiance path 'uirn RIEScheck. Each slab-on­grade assembly un the specified climate zone rnust meet the minisnu.M enei gy code insulatioin 11--vallue and depth requirerneirrirs. Ceiling 1: Flat Ceiling or Scissor Truss 1,400 39.0 0.0 0.030 0.026 42 36 Wall 1-front:Wood Frame, 16" o.c. 888 15.0 5.0 0.053 0.060 39 44 Orientation: Front Door 1: Solid 34 0.280 0.320 10 11 Orientation: Front Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 120 0.300 0.320 36 38 SHGC: 0.27 Orientation: Front Wall 2-front gables: Wood Frame, 16" o.c. 100 19.5 5.0 0.045 0.060 5 6 Orientation: Front Wall 3-right side: Wood Frame, 16" o.c. 576 15.0 5.0 0.053 0.060 30 33 Orientation: Right side Door 4: Solid Door(under 50%glazing) 18 0.183 0.320 3 6 Orientation: Right side Project Title: 2023_018 Aurora—detached garage "Report date: 02/27/24 Data filename: Pagel of 8 Wall 4-fight gable:Wood Frame, 16"o.c. Wall 5'rear:Wood Frame l5^oz� ' noo l�.0 5D OO53 n Orientation: Back � ' .000 27 az Door a: Glass SnGc o.]O 40 0.390 usaO 13 13 Orientation: Back Window 3: mnyVFi berg lass F,rame:DouWe Pane With Low-E ll3 0]OV O SNGC: 0.29 . ']oo 34 35 Orientation: Bark Wall 6-left side: Wood Frame, I�"o.c. Orientation: Left side ' ' 575 15.0 5.0 0.053 0.060 29 ]] Window 4:Nnyyri berg lass Frame:Double Pane with Low'E SHGC: o.29 24 O.]VO 0.320 7 V Orientation: Left side VVaU 7-left gable: Wood Frame, 16" u.c. Orientation: Left side 115 1e.5 5.0 0.045 0.060 5 7 Basement Wall I: Solid Concrete ur Masonry Orientation: Back xxa|| height: 9.8' 1.516 0.0 11.0 0.061 0.059 89 87 Depth below grade: 8.r Insulation depth: 8.0' Door]: Solid Orientation: Back zz 0,220 0.320 s 7 Window 5:Vinyl Frame sMGc: o.29 28 0.290 0J30 8 e Orientation: Back ME Forced Hot Air 96.1Apus Electric Central Air 15.15ss* Compliance Statement. The proposedbuilding design described h is consistent withth building | specifications, and other calculations submitted with the permit application.The proposed ng has been designed to meet the 2018 IECC requirements in ed ng has been dies, In 'y , W REScheck Version : REScheck-Web and to comply with the ma atory quire nts 11 d in the REScheck Inspection Checklist. Name-Title Signatur Date Name-Title Signa re Date Project Title: 2B23_Ol8 Aurora—detached garage Report date: 02/27/24 Data filename: Page 2of 8 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. # Pre-Inspection/Plan Review PlanValuefied Field, Value Verified `NH Complies? ..... Comments/Assumptions Section mptions 03.1, ID:Construction drawings and ElComplies Requirement will be met. 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the ❑Not Observable Location on plans/specs building envelope."Thermal Notes on sheet A-3 envelope represented on ❑Not Applicable construction documents. 103.1. .Construction drawings..�. ......_.. m�o .., .n ,,fl� ,,.,,,�• ,,.,�Y� �•ro�.. .... ........ ._ .�...... ...._...� ... and ❑Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for ❑Not Observable 'Location on plans/spec: [PR3]1 lighting and mechanical systems. Floor plan on sheet A-4 Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1� a .... Heatingand cooling equipment p. .... __._.. ...._. _..._mm ._ ........... ..... ,.,..._ .. ......� g g is' Heating: Heating: iComplies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hrw m ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Location on plans/spec: Manual J or other methods Btu/hr Btu/hr Notes on sheet A 3 approved by the code official. ❑Not Applicable �..... ....w. ......... w._ _....._w_ _ �........w.w ------a ...... ._........ Additional Comments/Assumptions: 1 Hi h Im act(Tier 1) 2 Medium Im act(Tier 2) 9 p . p 3 1 Low Impact(Tier 3) Project Title: 2023_018 Aurora—detached garage __�_....._. Report date: 02/27/24 Data filename: Page 3 of 8 Sectio .... .. ValueValue...... _..0 �._.Complies? _.. m _..a.. _. ,. Plans Verified., i IFieid ..r._.. i'es Commentsf sumption«� R " .JD Foundation Inspection i u�owtwpi 402.1.1 Conditioned basement wall R- R- ❑C'omplies See the Envelope assemblies [F04)1 insulation R-value.Where interior R R_ ;❑Does Not table for values. insulation is used,verification may need to occur during ;❑Not Observable Insulation Inspection. Not :❑Not Applicable required in warm-humid locations in Climate Zone 3. [ 05 . e..w...Conditioned a ��,, ❑Dom lies �Re Requirement Conditioned basement wall p q ment will be met. 1 insulation installed per es Not �g manufacturer's instructions. Location on plans/spec: ❑Not Observable Section A on sheet A-6 ❑Not Applicable ft 402.2.9 Conditioned basement wall ft lCo [F0611 insulation depth of burial e _.... mplies See the Envelope Assemblies lie p or ___..__. ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.21 A protective covering is komplies [ 12 to insulation protect and extends ainstalled Does Not Eot aption: e exposed exterior Requirement is minimum of 6 in. below grade. ❑Not Observable '❑Not Applicable 403.g ,,. _Snow and ice.melting..system -❑Dom pNot not applicable.ti : tFO12[ controls installedRequirement is ❑Not Observable , _. _..__m.mmm_.... ..ww......_ __www.........._m _...www .. ..._ . .._ w.u.w. .. ❑Not Applicable ..... .... .__............._..w_w__w _ w.. Additional Comments/Assumptions: ... 9 ....u... ............... ... impact .... .. ..... ow Impact(Tier 3) L 1 Hi h Imp-act(Tier 1) M I edium mp act(Tier 2) o� Project Title: 2023_018 Aurora—detached garage _ Report date: 02/27/24 Data filename: Page 4 of 8 .. .._ .._. 9Inspection�.-Plans Vern Value - Complies? Comments/Assumptions „#: Framing / Rough-in Section fled Field Verified Re ID; L. 402.1.1,e W_ _ . . _ �.. �. .. .. . .. � P ❑tom lies See the Envelope Assemblies 402.3.4 Door U-factor. U- U ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1 ....average). ... . ...... ... _...... .. _..__ .. .. . ....... w..,...-... ....._....... .... ....w..❑Does Not table e Envelope 402.1.1 Glazing U-factor(area-weighted U- U- �Co p� p Mies 9 402.3.3, ❑Not Observable 402.5 ❑ [FR2]1 Not Applicable 303.1.3 U-factors of fenestration products DComplies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 'Air barrier ._._... _... ..... ,. ,,, n,m „ �R,�, ,,,,, �,.�s. _ ...... ........... ._.__ rrier and thermal barrier ❑Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable r; _........_... „�,;, .._- ...._.. .... ....... 402.4.3 Fenestration ..... .......... ......... that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/l.5.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402 6]5 - sealed at housing/in terior lighting finish ����� ��� ������ � � ���������� � ����❑❑Doesplies Requirement will met. Not Location on plans/spec: s ec: [FR1 2 and labeled to indicate <_2.0 cfm ❑Not Observable p / p leakage at 75 Pa. ❑Not Applicable Notes on sheet A-3 405.2 1 All ou ducts i theunconditioned spaces R- R, --.-- ❑Does Not........ . Eompleton: Dudct tlocated p Exception: buildingor ely P he are insulated to >_R-6. ❑Not Observable building envelope. ❑Not Applicable _.. 403.3.5 Building cavities are not used as ❑Com plies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not - ❑Not Observable 403.4 HVAC ling conveying fluids R- � R �OCo plies Applicable Requirement ill be m [FR17]2 above 105 °F or chilled fluids Location on tans s piping Y 9 ......._.... � q w et. ❑Does Not below 55 -F are insulated to >_R- ❑Not Observable p / pec: 3 Notes on sheet A-3 ❑Not Applicable 403.4.1 piping. of insulation on HVAC � ❑❑Dompli t Exception: etion: Requirement i 403.4 1 Protection_... . ... ..�, ent is p g applicable. ❑Not Observable ❑Not Applicable . gravityc or outdoor are � � � „� � ,,,; ��� ElComplies Requirement will bem... [FR19] insta403.6 lled all o � et. oes Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: _.......pact(Ti w�.._.� edium Impact(Tier 2) 3 Low Impact(Tier 3j 1 High Impact(Tier 1) 2 M ..�..........._��_�_._wwww_.� _.w� .�..........�.. �w_.. �._�_w__ �_......_._� Project Title: 2023_018 Aurora—detached garage Report date: 02/27/24 Data filename: Page 5 of 8 e+�t lon .......... _ . lwd .�m. ,..._. ..... .. ,..,... ...._-� , ........ Insulation InspectionComplies? e Nalue 'o pliesf o ments/Assu ptlon�.s R IN 1,,-1-- .w._ .� . .... .�. 303.1 All Installed insulation is labeled G l omplies Requirement will be met. (IN1312 or the installed R-values ODoes Not provided. . Not Observable L]Not Applicable 4021.1, Wall insulation,R-value. If 402. .5, . mass wall with Xat least 1h of�the s is a ❑ Wood � Wood 0DoespNot table forlies See the Envelope stye Assemblies wall insulation on the wall [IN311 exterior,the exterior insulation Mass Naas Not Observable requirement applies(FR10). ❑ Steel _ Steel 13Not Applicable maul insulation n latio manufacturer's installed ... ._....m � 301 ,., , ,.,,... �,,... ��,,. ,, _ ........... .w. ....... ....... ..._m.. ...... . nstalled per 1�1orr�pNies Requirement will be met,. instructions. DDoes Not []Not Observable a.. No Applicable . ............ �......... ............ ._......_www.... Additional Comments/Assumptions: � ... ... ..... .. ....., . . 1 High Impact(Tier 1) NNedMum Impact(Ter 2} LOw Impact(1. . "1) Project Title: 2023_018 Aurora—detached garage Report date: 02/27/24 Data filename: Page 6 of 8 .. _..... _.., ..... ... .. Complies? Comments/Assumptions ..............m_. Section j � _..... ......,., . .�. Plans Verified f Field Verified r ents/Assum tions Final Inspection Provisions P P 1 Value Value 02.1 1!D Ceiling insulation R-value. R- NNN_ R- _ ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ElDoes Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 ❑Not Applicable [Fill' 303.1.1.1, Ceiling insulation installed per �. m ❑Complies Requirement will be met. 303.2 manufacturer's instructions.. ❑Does Not Re u' et [FI2] Blown insulation marked every n on plans/spec: 300 ft2. ❑Not Observable Section A on sheet A-6 ❑Not Applicable 402.. attics a with 2 3 _ Vented ........._ .. .... ..;. � _....__ ....... ....... ..... ...... ...... -.,.,._.. a air permeable ❑Complies Exception: Requirement is [FI22]2 insulation include baffle adjacent ❑Does Not not applicable. to soffit and eave vents that ❑Not Observable extends over insulation. � ❑Not Applicable <=5 ACH 50 - ACH 50 = ODomplies .. __ Require Requirement will b s ...t 402.4.1.2 BlowerCl in Zoe Zoe test 50 Pa — et. [FI 1 ach m Zones 1- and —3 ac s 3-8. ❑Not Observable Locationp / pec: Notes on sheet A-3 ❑Not Applicable 4027]3 determine air leakage with ft2 ft cfm/100 ❑Com lies handlers ar ocat d a ..-...- ....... Ducts are tested to ....... cfm/1... ..... ............ and air 00 PException: 1 2 Does Not handlers are located within either. Rough-in test.Total ❑Not Observable cospace. leakage measured with a pressure differential of 0.1 inch ❑Not Applicable Location on plans/spec: w.g. across the system including Section A on sheet A-6 the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4 _ Duct ti ghtness test result of<_4 .. ... cfm/1 ... ......w. .......... ...w_,. ...li .. �.._w...ti ..e .. ,www... [FI4] cfm/1 0 ft2 across the system or 00 �cfm/100 ❑Complies Exception Requirement is 1 y ftz ftz ❑Does Not not applicable. <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3 b 2.1 .Air handler leakage at designated _ %of d ❑Domplies. q Re uirement will be met. turer Y design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats [...'Complies Requirement will be met. [Flg]z installed for control of primary ❑Does Not Location on plans/spec: heating and cooling systems and ❑Not Observable initially set by manufacturer to ❑Not Applicable Notes on sheet A-3 code specifications. 403.1.2 Heat pump thermostat instal. led ❑ m Coplies Exception: Requirement is [FI10]2 on heat pumps. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable 403.5 systems have automatic or.. . ..... �m, ., ❑Do plies ..._...... Exception: _equ_ t i 403.5.1 Circulatingservice hot water plies Exception: Requirement is z Not not applicable. accessible manual controls. ❑Not Observable ❑Not Applicable G�ICom lies.,, ..........Re..uirement..... ....... ... ...... ._ 40256].1 falls not mechanical aof tested land listed pl stem p q will be met. z p d ❑Does Not HVAC equipment meet efficacy ❑Not Observable Location on plans/spec- and air flow limits per Table Notes on sheet A-3 R403.6.1. ❑Not Applicable 1 _-1 ..t( er 3).. High Impact(Tier 1) 2 Me dium Impact(Tier 2) ~ 3 ;Low Impact(Ti„ Project Title: 2023_018 Aurora—detached garage Report date: 02/27/24 Data filename: Page 7 of 8 ion 1 �...... . .,......._._... Plans Verified Field Verified # Final Inspection Provision s Value Value Complies? I Comments/Assumptions 403.2 Hot water boilers supplying heat ❑Complies I Exception: Requirement is 126]2 through one-or two-pipe heating ❑Does Not not applicable. systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. [03 ].1.l Heated water circulation systems 'ElComplies Requirement is []Does Not not appl�abe system return ... pipe is a dedicated return pipe or a cold water supply ❑Not Observable PP ; .,; pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heals automatically ElComplies Exception: RequiremeContro nt is comply with IEEE 515.1 or UL ❑Do Not not applicable. y ❑Not Observable adjust the energy input to the heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Demand recirculation water ❑Complies Exception: Requirement is [F130]2 systems have controls that ❑Does Not not applicable. manage operation of the pump and limit the temperature of the ❑Not Observable water entering the cold water ❑Not Applicable piping to <= 1049F. 4 Drain water heat [ 131] pB55 tested in Pot Potable Ovate rdnce with CSAs DoespNot... _..., recovery 'Exception Requirement is side not applicable. pressure loss of drain water heat ❑Not Observable recovery ry units 3Psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. [06]1 90%es have high efficacy ❑ Requirement Re uirement will be m... or more of .. et. 1 ❑Does Not ❑Not Observable Location on plans/spec: ❑Not Applicable Notes on sheet A-3 [04.1.1 no el gas lighting systems have ODomplies Not w Eot aptio :eequirement is 3 continuous pilot lig es ht. ❑Not Observable ❑Not Applicable �_ .. P �..............� ��., �...❑Complies.w.w ..._...... Requirement will be me 401.3 Compliance certificate posted. t, [F17]� ❑Does Not ❑Not Observable ❑Not Applicable [FI18] mechanic..._....�._................... ., ,w ,.................. ._............ ......... _.w...__... 303.3 Manufacturer manuals for ❑Complies Requirement will be met. 3 al and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable _ ......... � ._ �www....._...__._,. Additional Comments/Assumptions: h t(Ti Impact 1) . I Medium Impact Tier 2} 3 Low Impact Tip., 1 H g � .. �,2 i Mdi I P ( P ( r 3)......... Project Title: 2023_018 Aurora—detached garage Report date: 02/27/24 Data filename: Page 8 of 8 C2018 IECC Energy �(j Efficiency Certificate MOSUMMEMOMMIMMEM Above-Grade Wall 20.00 Below-Grade Wall 21.00 Floor 0.00 Ceiling / Roof 39.00 Ductwork(unconditioned spaces): Window 0.30 0.27 Door 0.29 0.30 Forced Hot Air 96.1 AFUE Electric Central Air 15.1 SEER Water Heater: Name: Date: Comments i The Aurora Detached Garage - 520 Zena Road, Mattituck HVAC Load Calculations for I Modern Age Home Builders, LLC 3080 Route 112, Suite C Medford, NY 11763 i 1 R ISMICl TULL RHVA,CHVAC LOADS i Prepared By: Jerry D'Amaro D'Amaro Engineering And Surveying, P.C. 20 Mariposa Lane Manorville, NY 11949-3356 631-878-7808 Tuesday, February 27,2024 I Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. w ... ...... .. .. ..... ...... o",-, 00ildontlal&Light Coift D � ,.. e Elite Software Development,Inc. � me'en rgy compuanw,Ratem The Aurora Detached Garage-520 Zena Road.Mattituck r FrpjectRed .. ...... . . . �. w Project Filename: C:AUsers\JTDWppData\Local\Elite Software\Rhvac 91Manual J -Aurora 520 Zena Road.rh9 Project Title: The Aurora Detached Garage-520 Zena Road, Mattituck Designed By: Jerry D'Amaro Project Date: February 27, 2024 Client Name: Modern Age Home Builders, LLC Client Address: 3080 Route 112, Suite C Client City: Medford, NY 11763 Client Phone: 631-569-4513 Client Comment: Company Name: D'Amaro Engineering And Surveying, P.C. Company Representative: Jerry D'Amaro Company Address: 20 Mariposa Lane Company City: Manorville, NY 11949-3356 Company Phone: 631-878-7808 Company E-Mail Address: jdamaro@optonline.net Company Website: www.damaroengineering.com Company Comment: w Reference City: Westhampton, New York Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 41 Degrees Elevation: 105 ft. Altitude Factor: 0.996 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 10 9 80% n/a 70 n/a Summer: 85 71 51% 50% 75 27 „ „ .... .,............ , Total Building Supply ...CFM: 1,117 CFM Per Square ft.: 0.307 Square ft. of Room Area: 3,632 Square ft. Per Ton: 1,372 Volume (ft'): 38,738 ,,.... ,. Total Heating Required Including Ventilation Air: 49,124 Btuh 49.124 MBH Total Sensible Gain: 24,776 Btuh 85 % Total Latent Gain: 4,418 Btuh 15 % Total Cooling Required Including Ventilation Air: 29,194 Btuh 2.43 Tons(Based On Sensible + Latent) 2.65 Tons (Based On 78% Sensible Capacity) /i Jii, y,J ilrvrM A i����%// Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Tuesday, February 27, 2024, 9:52 AM ,, , Rh -ft Wootat Uo ma rat VAC Was Eke '0$v 1 "wk i6 m EneMy Co if Raters ThoAuma Dwachad Gam -W n Road M ft�k Wge111a, us.1R _ e eee .ew an t Woof %� � b ,� re Winter: 10 9 80% n/a 70 n/a Summer: 85 71 51% 50% 75 27.00 ., ,. ... . Main Trunk R nou s Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00030 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 700 ft./min 500 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. . .,. ...._..:.....,,, ....,.... ..........w. Winter SUmmer Infiltration Specified: 0.282 AC/hr 0.126 AC/hr 182 CFM 81 CFM Infiltration Actual: 0.225 AC/hr 0.000 AC/hr Building Volume: Cu.ft. X 38.738 Cu.ft. 8„705 Cu.ft./hr 0 Cu.ft./hr �LO'Qiu X 0.0167 Total Building Infiltration: 145 CFM 0 CFM Total Building Ventilation: 110 CFM 110 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 10.96 = (1.10 X 0.996 X 10.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 18.29 = (0.68 X 0.996 X 27.00 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 65.75 = (1.10 X 0.996 X 60.00 Winter Temp. Difference) Winter Infiltration Specified: 0.282 AC/hr(182 CFM) Summer Infiltration Specified: 0.126 AC/hr(81 CFM) Blower Door Data: Wind Shielding Class: 4-Substantial Obstructions Building Stories: 2 Multi/Single Option: Single-Point Assumed n: 0.65 Pressure Diff.: 50 Test Flow: 1,937 Test AC/hr(Selected): 3 I I m._, _.. e r Tuesday, February 27, 2024, 9:52 AM . . ,. �� �, . ��� e� �J OVC 444 .....,,.. .. ��� ....,, �,... . ... d.",_ �...... .. . ..., ..... .... . . .... ..�.. µ-_______._wµ .. ....:�.:. _.......�.�._..._. ww_...._r_.-Ne1VReol ftZ�m..__:m........�eni...�„ Lat'�.... .Net v..::M Senµ:::: H 9�.-::..Clg � Act� .µ_Duct ys Sys Scope Ton Ton lion Area Gain Gain Gain Loss Size „.. ...... w._m .... ....... .. a CFML .. FMI CFMI _ Building 2.43 2 1 65 1,372 3,632 24,776 4,418 29,194 49,124 617 1,117 1. ,117 System 1 2.43 2.65 1,372 3,632 24,776 4,418 29,194 49,124 617 1,117 1,117 14x14 Ventilation 301 2,012 2,313 1,808 Blower 850 850 Zone 1 -C1q.:52%, Htq.:70% 2,430 13,804 1,406 15,210 33,013 430 650 650 1001 1-Basement 1,215 866 0 866 20,119 262 41 262 0--0* 2-Living Room/Foyer 369 2,234 200 2,434 3,911 51 105 105 1• 6 3-Kitchen/Family Room 584 9,585 1,206 10,791 5,982 78 4511 451 2--8 4-Dininq Room/Powder Room 263 1,119 0 1,119 3,001 39 53 53 1-A Zone 2-COq.:48%, Htq.: 30% 1,202 12,809 1,000 13,809 14,303 186 603 603 8x14 5-Master Bedroom 244 4,946 400 5,346 3,480 45 233 233 1-8 6-Master Closet 58 63 0 63 410 5 3 5 1-4 7-Bedroom 2 215 2,966 200 3,166 3,103 40 140 140 1 6 8-Bedroom 3 154 1,814 200 2,014 2,265 30 85 85 1- 6 9-Bedroom 4 142 1,601 200 1,801 1,108 14 5 75 1--6 10-Family Bath 61 132 0 132 501 '7 6 7 1--4 11-Master Bath 126 383 0 383 2,115 28 18 28 1.4 12-Hall/Laundry 201 904 0 904 1,321 17 43 43 1-4 Sum of room airflows may be greater than system airflow system has multiple zones and system room airflow he greater of heating or coolies,uses t _ _......�......w. ... .... .._.. __. _ ... _..a........___..............._............................ i 1 I C i i I Tuesday, February 27, 2024, 9:52 AM d ,. „ ... ne, �.. ....... Elite Software Development,Inc. Rhvac-Resldentlal 8 fight Commercial ifAD Loads i Home Energy Compliance Raters The Aurora Detached Garage-520 Zeno Road,Mattituck Duct Size Fre OW Duct Name Veloci Veloci F.�. � � . � ��� _. - ._.. . _ ..... w Room or Minimum) Maximum) Rough.! Design SP Duch Duct Htg Clg Act f Duct Reg Source ty Factor! U100 Loss Velocity , Leggy , Flow Flow }, Flow„f Size Size System 1 Supply Runouts Zone 1 1-Basement Built-in 500 750 0.01 0.1 0 41 262 0-0 2-Livinq Room/Foyer Built-In 500 750 0.01 0.1 535.7 51 105 1-6 3-Kitchen/Family Built-In 500 750 0.01 0.1 646.5 78 451 2-8 t Room 4-Dining Built-In 500 750 0.01 0.1 603.8 39 53 1-4 Room/Powder Room Zone 2 5-Master Bedroom Built-In 500 750 0.01 0.1 667.2 45 233 1-8 6-Master Closet Built-In 500 750 0.01 0.1 61.2 3 5 1--4 7-Bedroom 2 Built-In 500 750 0.01 0.1 711.3 40 140 1-6 j 8-Bedroom 3 Built-In 500 750 0.01 0.1 435 30 85 1-6 9-Bedroom 4 Built-In 500 750 0.01 0.1 383.9 14 75 1--6 10-Family Bath Built-In 500 750 0.01 0.1 74.8 6 7 1-4 11-Master Bath Built-In 500 750 0.01 0.1 316 18 28 1-4 12-Hall/Laundry Built-In 500 750 0.01 0.1 487.8 17 ; 43 1-4 Other Ducts in System 1 Sunp�MainmTrunk - Built-In 700ww 900 wm0 0003..- m,m 0.1 820.4 617 ,1,117w 14x14 mmmm w Summary _ System 1 Heating Flow: 617 Cooling Flow: 111..17, w i I I I I Tuesday, February 27, 2024, 9:52 AM , Rhp4a Regi�l�t1a18Lighx Commercial H�IAC Loads Elite Softrva�De�ielo hner�,Irfe: Home Energy Compliance Raters" rgkhaven JAY The Aurora Detached Garage 524 Zena Road Mattduck 11719 u. Total But !in Summary Loads �. ... (t .. ... ,,' United Window: Glazing-JTD United Windows and Doors, 241.4 4,346 0 4,114 4,114 outdoor insect screen with 100%coverage, light color drapes with medium weave with 50% coverage, U- value 0.3, SHGC 0.3 United Window: Glazing-JTD United Windows and Doors, 37.2 670 0 640 640 U-value 0.3, SHGC 0.3 United Glass Door: Glazing-JTD United sliding patio door, 42 706 0 1,343 1,343 U-value 0.28, SHGC 0.31 PCH Outside BSMT: Door-JTD, U-value 0.19 20 228 0 80 80 PCH Front: Door-JTD, U-value 0.28 42 706 0 247 247 PCH Front Door: Door-JTD-Therma-Tru Fibrt-Classic 18.7 258 0 90 90 with Sidelites, U-value 0.23 R-11 Blanket-8: Wall-Basement, Custom, JTD 8' below 1173.3 3,833 0 56 56 grade, U-value 0.052, above grade U-value 0.091 R-11 Blanket-0: Wall-Basement, Custom, JTD 0' below 92.8 479 0 66 66 grade for doors, U-value 0.086, above grade U-value 0.086 R-20 Batt+XPS: Wall-Frame, Custom, JTD R-15 baits+ 2386.5 8,020 0 1,030 1,030 1" Rigid Foam continuous, U-value 0.056 R-18 Gable: Wall-Frame, Custom, JTD 2" SPF+ 1" Rigid 310 1,079 0 138 138 Foam continuous, U-value 0.058 SPF R-39: Roof/Ceiling-Roof Joists Between Roof Deck 13.7 29 0 10 10 and Ceiling or Foam Encapsulated Roof Joists, Custom, JTD, U-value 0.035 SPF R-39-ad: Roof/Ceiling-Roof Joists Between Roof 1354.1 2,844 0 948 948 Deck and Ceiling or Foam Encapsulated Roof Joists, Custom, JTD, dark asphalt, U-value 0.035 R-0 BSMT: Floor-Basement, Custom, JTD, U-value 0.2 1215 14,580 0 0 0 Subtotals for structure: 37,778 0 8,762 8,762 People: 8 1,600 1,840 3,440 Equipment: 806 8,249 9,055 Lighting: 1400 4,774 4,774 i Ductwork: 0 0 0 0 Infiltration: Winter CFM: 145, Summer CFM: 0 9,538 0 0 0 Ventilation: Winter CFM: 110, Summer CFM: 110 1,808 2,012 301 2,313 Blower Heat Gain, 249 watts: 0 0 850 850 Total Building Load Totals: 49,124 4,418 24,776 29,194 [thick"', ............. ... .,, Total Building Supply CFM: 1,117 CFM Per Square ft.: 0.307 Square ft. of Room Area: 3,632 Square ft. Per Ton:. 1,372 Volume (ft'): 38,738 f Total Heating Required Including Ventilation Air. 49,124 Btuh 49.124 MBH Total Sensible Gain: 24,776 Btuh 85 % Total Latent Gain: 4,418 Btuh 15 % Total Cooling Required Including Ventilation Air: 29,194 Btuh 2.43 Tons (Based On Sensible+ Latent) 2.65 Tons (Based On 78% Sensible Capacity) to .:..,, „w,,,,,, Rhvac is an ACCA approved ManualJ, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Tuesday, February 27, 2024, 9:52 AM Hbme Energy Ca rr tit r T ' ur r De Ga ,.. Zen SWt. r P"00rr,. Tt m Z2— „s,.�..,.,..,,,,,,. �,....... All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I i f 1 f I, I 1 I Tuesday, February 27, 2024, 9:52 AM „, .. _..�. ...... ....... e, ,�.�,e, _. �...n. _a... . , „�„ ..... .......... ... �.,, Manual S. ffor a.1p Dates . .< .,...� �.�„I��a /,�,,,., � „i„./ „„i„w.,.,,.�,�, ,„���„/�✓/i//�/,/�i/ / c,c„��//i ur ./.,�/i,//L,ii,,,,,,,iiirr:�,rc,,,,,.,//ii/i. ,,,,,e„e„,umL/„/�f���//,%/xk Cooling: Outdoor Dry Bulb: 85 Sensible Gain: 24,776 Outdoor Wet Bulb: 71 Latent Gain: 4,418 Indoor Dry Bulb: 75 Total Gain: 29,194 Indoor RH: 50 Load SHR: 0.85 Supply Airflow: 1,117 Entering Dry Bulb: 76 Entering Wet Bulb: 63.4 Heating: Outdoor Dry Bulb: 10 Sensible Loss: 49,124 Indoor Dry Bulb: 70 Entering Dry Bulb: 67.3 Indoor RH: 30 Supply Airflow: 617 This system's equipment was selected in accordance with ACCA Manual S. Cooling: Model Type: Standard Air Conditioner, Outdoor Model: ML14XC15036-230B**, Indoor Model: CH35-36B+TDR+TXV AHRI Reference Number: 9150115Nominal Capacity: 33,200, Manufacturer: LENNOX S � ,e W� 0 ��I 7 35400 1.9 0.86 28674 0.96 339.,.0 t 75 2 8 7 35400 1.9 0.61 21594 0.74 2619 . ,. 1.9 Cfµ. 4.._......_ 38,0 0.79 2923 � . Interpolation Results: Percent Load of Load Sensible Capacity: 26,720 24,776 108% Latent Capacity: 7,504 4,418 170% Total Capacity: 34,224 29,194 117% Power Input: 1.90 Heating: Model Type: Propane Furnace, Model: EL296UH070XE36B-*, Nominal Capacity: 64,000, Manufacturer: LENNOX INDUSTRIES, INC. Results: Percent Load of Load Heating Capacity: 64,000 49,124 130% ..... ......... ...............,..,. ..........n ...... ........... ......... . Tuesday, February 27, 2024, 9:52 AM V*Aurom,Wached20 Z na ow* S " ra ......9 Room, Load S, l m' // , i/// � / / / ,�i / // // // is / i��iri � ✓ i „.Frei i�-aia,�,� �/�im4d: r,� er.,,. ����,i„l,✓//�,.������ ���n.��W,,,,,.,,,�c„/�✓,,,,����i� „„„� r� ,,.��iw iii,�,/,�//% ,�x��/G,,,,,,i Latent Capacity: n/a 7,304 Btuh Adjusted Latent Capacity: n/a 7,504 Btuh AHRI Reference No.: n/a 9150115 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 85F, SOWB: 71 F,WODB: 10F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain:24,776 Btuh, Lat. gain:4,418 Btuh, Sen. loss:49,124 Btuh, Entering clg. coil DB: 76F, Entering clg. coil WB: 63AF, Entering htg. coil DB: 67.3F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req, clg. airflow: 1117 CFM, Req. htg. airflow: 617 CFM I i i I I 1 I Tuesday, February 27, 2024, 9:52 AM \ . Residential Plans Examiner Review Form Form for ���� ���HVAC System~ ~�~ __ - _- 8 Mar 10 County, Town, Municipality, Jurisdiction Header Information REQUIRED ATTACHMENTS' ATTACHED Comdnmmtnr ...... Manuo|J1 Form(and supporting wndmhoom): Yes No Mechanical License# o,mJ1As ronn"(amu supporting worksheets): Yes No ------------------------------- OEM performance data(xoatmg.cooling,b|uwor): YooLJ No Building Plan# Manual o Friction nooammmu000t: Yes El No 0-----------'------------------------ Duct distribution system sketch: Yes No Home Address(Street nrLot#, B|ook, Subdivision) Winter Design Conditions Building Outdoor temperature 1,0 OF Orientation(Front door faces) West- Indoor ________ , North,sao v�m ouum.wmmeuo wn�hwoo.00umvoo.nnmnwo� mmpom�m �K� r mumuo,muoomvma Tv�|heat moo 1 ��� Btu/h ---�-- ----,"~-�°�-^ uvnmuonoufloor amu Sq Ft Summer Design Conditions '----^�����k^�------ Outdoor temperature 85, OF Number ofoccupants 8 Indoor temperature OF ��ind�ym* -----«=� f Grains difference 27 LGr 96 Rh smm overhang depth Ft Sensible heat gain 94776 Btu/h Internalo»auo -- �n�p�� E eve Lammheat gain Btu/h en"u".«=�".°m -�_____ _ Depth Window Total heat gain ___2 Btu/h Number mskylights Heating.Equipment Data. Coolin-g-Eq u i p rn e nt Data- Blo,w-er-Q, atal Equipment type Furnmce Equipment type �oenngcr� {�FK8 p"��m.*°�pump,u"n°,.�= A*o""umon",x°*n"mn."u ----""—~°- Model M»«»| K8L1----_-___E������D��������, __-_--'---- Coo|inUCFM 1 1 1-7 CFK0 Heating output capacity Btu/h Sensible cooling capacity __ Btu/h Heat pumps capacity at winter design outdoor conditions Latent cooling capacity Btu/h _'________- Auxiliary heat output capacity Gtu/h Total cooling capacity 34224 Btu/h �HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) ou��m�nu|uuoou(m,�e) Design airflow <�FK8 L»noo�uu»P|vuu�� Ft ----------- ------- Trunk Duct: Duct board,Flex,Sheet metal, External Static Pressure(EaP) |yyC Longest return duct: Ft Lined sheet metal, omo (specify) Component Pressure Losses(CPQ |VVC To�|sf�cuv�Lwngth<TEL) Ft --- - ------------------------ ------ �m��o�� Dumboand. F ex,axommmo|. unouvxommma|' Other(specify) 4vai|amea�ucp,�sumK�ep) |\8K� Friction Rate: |VVC ASP~ESP CpL Friction Ra*~(ASP"1mm�rsL 1 declare the load calculation. equipment selection, and duct system design were rigorously performed based on the building plan listed above, I understand the claims made on these forms will be subject to review and verification Contractor's Printed Name Deho �������������_ er. Trace Chris Dwyer <cdwyer@lkma.com> Thursday, December 7, 2023 12:26 PM Betsy Perkins; Dwyer,Tracey Patricia C Moore; KYLEE DEFRESE eject: RE:ZENA ROAD; 1000-106-2-43.2 there. was submitted on November 22, 2023. tegards, Chris From: Betsy Perkins [mailto:betsy@mooreattys.com] Sent:Thursday, December 7, 202312:13 PM To: Dwyer,Tracey<tracey.dwyer@town.southold.ny.us> Cc:Patricia C Moore<PCMOORE@mooreattys.com>; KYLEE DE FRESE<kylee@mooreattys.com>;Chris Dwyer <cdwyer@lkma.com> Subject:ZENA ROAD; 1000-106-2-43.2 hi Tracy. Chris Dwyer asked that we forward the attached to you. This lot is een tt from nxer er because it received in 1986 both a "set-off' and an area variance (Appeal #3517). three Captain Kid lots were merged& re-split into 2 lots (now 1000-106-2-43.1 & 43.2) 1 am attaching both the set-off and the variance. Please give us a call if you have any questions. Thanks. PLEASE REPLY TO ALL!! Betsy Perkins, Paralegal Mailing & Physical Address: .....m_.. 51020 Main Road Moore Law Offices Southold NY 11971 William D. Moore, Esq. Fax Number: 631.765.4663 Patricia C. Moore, Esq. 631.765.4643 631.765.4330 v�rww.mooreett s com .:NINE External Email: This ellnaii originated frorn outside f,KMA, Pease do not click links, respond or open attachments unless you trust the Sender. i l EOGdTrox �"°"` Nh ~Y � � �v�) t �+unnvs awDwrzrx�rfsva:.sg � v N 81'32`47"a 13359` j'9 - ^. ( } W.W V 3 o LOCATION MAP l jt Q f Off^ / gi � i 1 � i � Tt o S1cm'93u�rnLE tl AS 4 f 5 91.32'a3,'W 79.27• CAPTAIN KIDD DRIVE i (sQ'won E SITE PLAN TEST_HOLE O Er AiCOONAtll GEOS6 CFS QN B/2S/22 T.S. �. PRCVEvtt tHF L „� E%5�>:con^aDR � — 2 2 kF UR0.ITEG tt,YOtFi PoR BEtAOH�CaRAGE L G PR�PSEP cDes IATW¢� _ ,£ _ N PER wEN15 FROFt SCD4 — = tt0 P3 GSDdeMoxt`M'.rtrcvc waewtE --"' ' -_.RY— PES�FIFt16N 5 tFFftp':.BY---. 3 as cew Dn1ID s-s 3 , •ca m summ ci&.a on -- 'i- j •� •" .}� T P-`` I -RENSIONS m vac Fua wac R uR es.cwsx 524 ZENA ROAD MATTITUCK. NY.11952 ----__ —v—resn z-,n-.ROPc .r PEE _, � P �„s,�„�� fk =s�• � ' PROPOSED RESIDENCE SANITARY PLAN a,::Ypr a e24202< L K CLEAN _. rzs tq.E etGmm. -+y3 s 031E'<➢2B � s -. M ASSt3C3ATES,�P.C. cv unmz;Rasw2 _ `� ' c<.yMt.ey MF/CFD � sar.. AS NOTED N4' MF JUNE i } _. SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES .+� l vP4m«�e,- �$ n,23N ?0?3 023 ^ POWER SUPPLY CONNECTED TO CEDICATEG IX,v bL.S 5L PW SE �pC p� r+`—2'U C:R., eRFNL,R AN rllE Et£OTRICAL FAVEL F4L PPE FROM MAD'R' REtE SAF£tt UD f FW CIEAA'l i UT Y P4NEL PROPJS D F G BL@WER TO fIR MTFJ(E "'W j et+NDtE ON PIASBC PL'LnOK 20"COVER F40PDBED M4C"a R6411 R B OWE=.FOWER COVNECROn �E1F.CTAYC ��PER M&FhCPJRER'S I R15ER(ttP.FCR Art 3) MIN.<'D!/. �Ei:41.5 +' - RE DW.ED TO CONRE AS PER c—rc t REMENS SG2 M N t MBNUFACT RE 5 EO FEM"Tl!5. - I _B 6 3 3S PVC FIFE P(tCHED , _ � � - zt iz -HDFE VENT j HAr<cDAi Fl�TER Ts"Mn. � k s n'� r r aftD4E(aT4DE 36 M.-FRC ANY WINCOW OR DOOR. [ i € I '__ P�i0 } �f—PNnOK " V I _.OPSP,RE WI'N VER Ff E Fl20M.FtnG R' I .: FLOWER TO lAR NTAKE 4-e, T. � ENDCM iliE t �)�rD cx oR ENo FLED I FER Mu.�:FncrvRER.s —�`—`�'�-`—�`--•—. I I g t I PROPOSED U G � � r E-CIRiC I �- •. ' PIPE PfTCHEC t t I t --- -D tta-PFR +'scNas we FwE gF-T P a cwi taw..wc P,w I € M.M.tz"COMPACiID SYND OR L PPE TO PENE,RnTE F r N W,+u N,N.z' � r � G35TRI8UTIt?NfSAMPLIN6 �#ANHC}L� N �S BUILDING CONNECTION DETAIL OFaDE_tP2.BD , �4NDTE covER BELDW 4R�E I IA OWTS FUJI CLEAN CEN5 500 GPDt N _� N.T.S. 4. - Ax-- z Er 6"Te.ICK$!AE ( ♦ex£T - T,ET wx� SDR as -- PrsCfiED __ •" - - •-=kk` I St,,— ae.e R—v s.}'_._f = I : I f 1 i� l (31AavaemA3m {N,rem o F a 3 -rice aNsTE a ..7 Aa A'ru¢ .. s i ...., N TY Li<5�I.MA_ CFF. :.Csx_ 1 Kam•" O�ail.�u PLAN VIEP.�*®+ct s aE.eG ._.-- � s j ,n.T ate, 1 v �It,^,QVtTS FUJI CEN6 7 {z f f I ? ( I c I I 3 # I I t {I SECTION A-A 1W SECTION B-B VIEW ' I I i € � IAA �WTS FU,3E CLEAN CENS 500 GPQ I - I € �aa, N.T.S. �.}--I � i i �� I -n-2+ MP UFYrTEL uran Foa oErncnEo-caencE -cic 6 , I I wre � -.. S oscwPTroN ..LAPPROY.cr I I REVISIONS a d a— E1i 520 ZENA ROAD , � I I� iI k�ATTtT K NY 11452 Mn v PROPOSED RESIDENCE " INlOA ,�+559flT--^ a -Y'Y.--= T SVJD II GRAtEl i 3 xiW 1 a SANITARY DETAILS me—:—_1 m—_..... L_K.MCLEAN ASSOCIATES.P.C. --- a._-_r-__s -__. L TYPICAL LEACHING POOL DETAIL € NFjCFo3�. AS NOTED V.T.S. .. f3 ME RUNE 2023 SZ roF�er RAS Na 23098.000 kAC QRI INDOORS I OUTDOORS [ 1 POWER ! iX ENCLOSURE! ''y sG:TR�vANEL PANEL - - a --� 1 IR ` —— APPr- (( 1 ALL M9R 4GN cBE 5 P 5 f - D� at -^ e 1LL f is lX �YL`-= - vr, v'alr _� J<pnn i FiNiSH'e .GOf .- < e' '�j` PY-b,NASI£WATER i- - sF _ TFFA'-'hiEM StS1EN s — ke c-E aSn l+v ossev�tr:y F vent_rc. rery a 4-=� (Nate v tare 0 epFr S. 'il iri44er te=aviv.Tal.c Sivp tuner e+.1 � i OWTS SINGLE LINE DIAGRAM _e v , ; N t i s +E..M'tii £ i V1S 51>�N` - ,• � i £. F�., yr>�.x_..� BEACON`�—: e i r _ TO R CONTROL riIRING TO On ^ n ' € I' � �hsR^141 ED COMRO RNiEL AIR TO BE At. ,.el—n S _ t (s oORFf6 vlt+COBS °A 05 -2 B t ---_i i -. @ O s I EN a t SUPPLY i I / i E'J R tiNr TO ONIS �. v- t,=..,.r FujiMMC 1 T,co.szi NS G 6 I V � w O B P R NCLCslwE �6"CONCF£iE et9WFR P➢ « u rG Pv h.:l QR _.. ".-f. E l fRU%ee CONTROL PANEL & BLOWER DETAIL N.Ts. Ta ewttx.a�vre mro A uEnwe+ram MMlR.tLv.MtvVL£G AiAST16-+�KK�W � WORK ��SCLYtS iN1TErnON / RFD. 1 cv m THE BOr10.N trE eN^ swo -°` . a I& ff THE UA To ire wcx. Btn 4 of- ..—E- _ :xm swt. r TrE , nw Es�a. TROY RtRDUr G4elNrr eF .NF frF«'mow = Nxt StN'1 tJ+.e,"r WSruem QAiE 6Y --...a RE%4 ON NPROY 81,-- ''*P IC A' C�EANOU7 CSETAIt< Tx. � TM2 TRUTurxr smEr1 wRx urssax muNtt REVISIONS - s MA ZENA ROAD AND TPE aRORER;r ow�ax m;L a pRarom m=_Eusex ecuarc oEnwm�a��x.Tx s«w�Es � 1 i A#ATTtTUGK. NY t 1952 ---_. w.r c+w�cE xxecER swu iwr eE esrnum wsN¢u�of mr•a.Ts. rzFcnncrx uses rxare> 6u,>,vNc m,Be it•owu.wxrR exwx vwi 1ENaosfn xu t' I,HIM 3':iE 1` PROPOSED RESIDENCE - ---_-.- QWT59ULLBE 4AND—XM SANITARY DETAILS 2 L.K.McLEAN ASSOCIATES,P.C. rn AS �2� MFJGF�ASMF,, S3 =/Z �w° T _ — V N 51*32'47"E 133.59' &TG IE J V ry 0 LOCATI N MAP % ciccuF�noh NT.5, Nj r EL 91.6 -------I E-5 S 81-32- 79-17— CAPTAINKIDD DRIk (W wmQ SITE PLAN an SITE PLAN DATA. S FOND LAND DEVELOPMENT L-C TEST HOLE 520 ZENA MUCK, NY, 11G52 I . C.——1E.—.1 VW�2 1000 06 00-02.00-C43,002 cif NEW _�W RD,MA7 SITE AREA: 13,825 S�/0.3'7 ACRES LIMITS OF GRADING! 13,325 SF/0.317 ACRES -------- ..... sp , 2 1 11 LALQVLAIKLN.$- REaau-cmv-I;L�v /397 REVISIONS J-5 520 ZENA ROAD neap ;III;H MATTITUCK. NY 11952 7 n ul I ...... 520 ZENA ROAD, MATTITUCK, NY 11952 LOP STORMWATER MANAGEMENT PLAN C�,RTE: WASHOUT QET�AIL LEADER—DOWNFALL_ DETAIL A'NOTED pmw-1— MF I�IARCl 2024 C 1 9 4 aFOJE r _ a g'r rt w a v<,se _ s-� IE N 8132`47"€ 733.59`.E) eeax.n TZ xr s ¢u T III EF O ES � SJ YE a E i < '4Sxr < �o — 11 R � D LOCATION MAP ,m— - _ PsTl12 nm t au waga Es� r t NO BLILZ3LNG D . r i5 'ate R a CAPTAIN KIDD DRIVE t� t SITEyug- PLAN zggv RHO I SITE PLAN DATA: tF=ONK LAND DEVELOPMENT LLC TEST HOLE n ZEINA R kW I:UoK NY 11952 0-1OS.0 e . `Q4-.OQ2 6r ucCO c. a E'G o'ol�a(es u f?MCA' =[+'T'G4 A N^�'0CE favtl ..._ ITE A;F 8 SF C i. ACRES M1.I.5 OF RALI\G: 13 _F,`0-317 ACRES _ S 1 7 T ssg REV ONS E2 520 ZENA ROAD NIATT TUCK. NY 520 ZENA ROAD MA_TITUCK,LNY STORMWATER MANAGEMENT - 11ECQhCR'TE WASNGUT CcT'[f i�'OFR ^OWNFAl.� ^-s. -€uanR cTg�cr�,:€v��Aw^c L.IC McLEAN ASSQCkATES.. DETAIL r. .�a� .—a ar MFjCF a- AS NOTED —� MF MARCH 202A - u- B, RAS 23048.000 PART OF LOT 154 PROPERTY SURVEY CS 86°00'30' E Map) PIN OF - N 81`32'47' E 133,59' wIT wrm LOT 153 AND PART OF LOT 154 ON THE AC 6•PVL E SUBDIVISION NIA-P OF L ' CAPTAIN KIDD ESTATES FILED JANUARY 19;1949 AS MAP NO.1672 1 SIITJATE AT 7 7� PART OF COT 154 MATTITUCK Ql� arq / f o TOWN OF SOL'THOLD SUFFOLK COUNTY;NEW YORK ———— —_—__=r_ / W N AREA OF PARCEL = 13,825t SQ.FT. OR 0.317t ACRE LILT 152 SY. 3 i a NOTES �eVACAUTivon➢£➢ W g .x 1. MEASUREMENTS ARE IN ACCORDANCE WITH U.S.STANDARDS. e\ \ � (( j: 1.LSF gsz} i Gll "'ceJz �_ ,i�t�- + .�y 3 2 LONG LAND ZONE ARE IN NEW YORK STATE PLANE COORDINATE SYSTEM NAD83, a �\ \ Sit Z S ' ^ LONG ISLAND ZONE pv p i zssz � O \V �� —_ __ '-- -- �zqs� • �N a, 3. ELEVATIONS REFERENCE NAVD 1988(GEOID12A). . 4. UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND SURVEYOR'S SEAL IS AVIOLATION OF SECTION 7209,SUBDIVISION 2,OF THE NEW YORK STATE EDUCATION LAW " LOT 153 � T� 5. ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WfTHAN ORIGINAL OF THE LAND SURVEYOR'S"EMBOSSED"OR"INKED"SEAL SHALL BE CONSIDERED TO BE zP s7sr VALID TRUE COPIES. ti! 6. CERTIFICATIONS INDICATED HEREON SIGNIFY THAT THIS SURVEY WAS PREPARED IN ACCORDANCE IMTH THE EXISTING CODE OF PRACTICE FOR LAND SURVEYORS j _ I ADOPTED BY T,ENEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND -, zgrcT SURVEYORS.SAID CERTIFICATIONS SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY, i GOVERNMENTAL AGENCYAND LENDING INSTITUTION LISTED HEREON ANO TO.THE 9J— zsus �' �._ ASSIGNEES OF THE LENDING INSTITUTION.CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. j��j ` 7. RIGHTS-OF-WAY NOT SHOWN ARE NOT CERTIFIED / reu If s �"' xzrss E_ THE SURVEY CLOSES MATHEMATICALLY. z sasr ._.� y60 �ysru 0.6,N B. UNDERGROUND UTILITIES IF SHOWN ON THIS SURVEYARE FROM UTILITY MARKOUT ag,w LOCATED ON THE GROUND A,NDIOR RECORD PLANS.BEFORE ANY IXCAVATCA IS TO BEGIN,ALL UNDERGROUND UTILITIES SHOULD BE VERIFIED AS TO THEIR±OCATION, / SIZE AND TYPE BY THE RESPECTIVE UTILITY COMPANIES.. 11- • u-452: \ 10. THISS+URVEYWAS MA DE WITHOUT THE BENEFIT OFA PILE REPORT SUBJECT TO F,F.F- p stir E� al3 ��''. NUDLL � ANY EASEMENTS,CONDITIONS OR ENCUMBRANCES AN UPDATED TITLE SEARCH MAY LEGEND A-._ CH erg. fir, — x �— :N UTtLtiY PLR.£ REVEAL.} .5,.� a 1 -- - UTILITY LIGHT PILE "..-^ -*>__ - Jq r EB6E IIF PAVEXENT en s�z, q*72 Fy qs� ¢ - - - -UTILITY POLE - Yp TER VALVE I -SIGNS xsz� \ zss+s zsase zscse _ EP - EDGE OF PAVEMENT ^SIB �' \ 10712612311 T.L.S. T.L.S. ;ADDED FILE MAP BEARINGS BY ➢ESCRII+I4ON IAFFHOV.HY MAILBOX �"CAPTAIN KIDD DRIVE @@ 0 REVISIONS SP17T ELEVATION f>C ''t4 ` a— SANITARY VENT ssss� (50' WIDE) S� t"1.STj CERTIFIED TO: Town of Southold Speonk Land Development LLC Suffolk County, New York Eminent Abstract Inc. 520 Zen. Road Westcor Land Title Insurance Company i Mattitu.k, New York I hereby certify that this map was made from an actual surrey Topographic Survey SUFFOLK COUNTY REAL PROPERTY TAX MAP — DISTRICT 1000 OS#}528 completed by me on 06108/2023. L. K. MCLEAN ASSOCIATES, P.C. S _ CONSULTING ENGINEERS &LAND SURVEYORS i �('"�(rJjJ, 437 So.COUNTRY ROAD,HROOKEAVEN,NEW YORK. SECTION 006.00 /1 icy € BLOCK 02.00 ��� �/�GIQ �Msm ez c.w_�Nx. r•=2a• '�' LOT 043,002 TAMARA L.STILLMAN,P.L.S. m„„,ar. D.M o6nsiaaP3 A1a309allo?Sao Zena Rd Ma ttttuckt Survey DeAt1i4^a wingsl23d98.000 Sury 1. 7/26/a0P3 9J0 AN Tamara StM- NYSPLS No.50528 q ovea eye T.L.S. 23D9a.01lP