49652-Z
�p�pguFFOlp�oG Town of Southold 2/5/2024 0 P.O.Box 1179 " M 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44928 Date: 2/5/2024 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 7785 Route 25, Laurel SCTM#: 473889 Sec/Block/Lot: 122.-6-29.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/1/2023 pursuant to which Building Permit No. 49652 dated 9/7/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations, including indoor recreational facility(golf simulation) and office space,to existing business building as applied for per ZBA Special Exception#7795, dated 6/15/2023. The certificate is issued to 7785 Main Road LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49652 10/2/2023 PLUMBERS CERTIFICATION DATED 10/20/2023 J. Ns Inc Auto zed i nature �o�SUFF01,�� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49652 Date: 9/7/2023 Permission is hereby granted to: 7785 Main Road LLC c/o Troy & Joan Gustayson PO BOX 247 Orient, NY 11957 To: alter existing business building to an indoor recreational facility (golf simulation) and an office space as applied for per ZBA Special Exception approval. At premises located at: 7785 Route 25, Laurel SCTM #473889 Sec/Block/Lot# 122.-6-29.1 Pursuant to application dated 6/1/2023 and approved by the Building Inspector. To expire on 3/8/2025. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $1,572.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $1,622.00 Building Ins or pF SObTyo� Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 i� Sean.devlinCa.town.Southold.nv.us Southold,NY 11971-0959 coUNTI,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: 7785 Main Rd LLC Address: 7785 Route 25 city:Laurel st: NY zip: 11948 Building Permit#: 49652 Section: 122 Block: 6 Lot: 29.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Modern Electric East License No: 55647ME SITE DETAILS Office Use Only Residential X Indoor N Basement Service Commerical Outdoor 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 45 Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe 3 Heat Detectors Disconnect Switches 15 4'LED Exit Fixtures 7 Sump Pump Other Equipment: 2' Track Light (4), 12' Track Light (1), (4) New 15A Circuits Notes: New Outlets, Switching and Lighting Inspector Signature: C v Date: October 2, 2023 S.Devlin-Cert Electrical Compliance Form I SOUTyo! Town Hall Amex Telephone(631)765-1802 54375 Main Road —�} Ir Fax_(6311\)7 -9502 \ P.O.Box 1179V� Southold,NY 11971-0959 NOV 1 2023 BUILDING DEPARTMENT TOWN OF SOUTHOLID lt?'T(?:If W r.^^; , . CERTIETCATION Date- 0 3 Building Permit No. Owner: 7 78E Mo (N R 1. /� L- (Please print) J Plumber: .2-e- ' !ti ( . (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. - / �(P Mrs!` l ers Signature) Swom to before me this 30 G QUO—j day of 20 �3 JO A. Notary Publicc--Stateto of of New York No.01 MA6164838 Qualified in Suffolk County /�/�/ My commix lon fixy,04/20/202,7 Notary Public, '5,1!z count, ,.o�aOF SOUTy�6 Y��T c? 4 9.6.,5 a TOWN OF SOUTHOLD BUILDING DEPT. °`�caurm N� 631.765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: C1 a1i e- /¢C Za>2c S.n�ef DATE %//Z/�3 INSPECTOR �' " l y"✓J �o�aOF SUUly�6 4 ! V/5L —7r7 &-,5 TOWN OF SOUTHOLD BUILDING DEPT. `�rourm �0 631-765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: C(r I &I140o,� DATEIZ3 INSPECTOR * TOWN OF SOUTHOLD BUILDING DEPT. �0 • �o `"rovrrn N�'' 631-765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] }NSULATIOWCAULKING [ ] FRAMING /STRAPPING [ /FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: S I� 4 - v V0 ( I n 4,t 6 �1 .Pig in.P.�� M vYl 1� 01� err' Y DATE lb )o-y INSPECTOR �o�aUF SOUTyo6 Jv // (251'WC L 7/ b ` e- ( %6L D f TOWN OF SOUTHOLD BUILDING DEPT. 631.765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: L D-�s CQ�� DATE INSPECTOR �nZa�-P� f TOWN OF SOUTHOLD BUILDING--DEPT.-- - - ymuxn � 631.765.1802 1 2Z b — z. 2. , INSPECTION V96s Z [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [�,OINAL [ ] FIREPLACE & CHIMNEY IRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL RE RKS: 0 e-y coc � o 66 .ram 6-se/e � 9 s 5;w o S-en a� 0,�. .S DATE Z INSPECTOR � f ` L Ili IC II 1U1 1� MAR 2 4 2023 t Condon Engineering, P.C. TOWNOFSO i"OLD New York State Licensed Professional Engineers 1755 Slgsbee Road 631-298-1986 Mattituck,New York 11952 Fax 631-298-2651 www.condonengineering.com March 22,2023 Mr. Mike Verity Building Department Town of Southold Town Hall P.O. Box 1179 Southold, NY 11971 Re: Golf Simulators/ Times Review Building -7785 Main Road, Mattituck, NY Dear Mr. Verity: As requested, I reviewed the existing sewage disposal system for the above referenced property to determine if Suffolk County Department of Health Services (SCDHS) review is required. I spoke with Lewis, who is a reviewer with the commercial section at SCDHS, he told me that the existing sewage disposal system may be used if it was permitted by the SCDHS and if the proposed sanitary flow can be accommodated by the existing system. The existing sewage disposal system currently installed was approved by the Suffolk County Department(SCDHS) of Health Services at the time of the construction of the building in 1991. The existing sewage disposal system consists of a precast 900-gallon septic tank and two precast 8'diameter x 8'deep leaching pools. The system has a capacity of 450 GPO. The building will be used for office space and recreational space (golf simulators). The proposed sewage flow is 423 GPO which is less than 450 GPO. Based on my observations and to the best of my knowledge,the existing sewage disposal system on the property is adequate for the proposed uses and review by the SCDHS is not required for this project. Please call me if you have any questions or require additional information. Yours truly ��pF NEW Y C-D C0�pSEPN ��.7 a �a ,l o c �F don, P.E. ZACKERY E. NICHOLSON, RA ZEN ICHOLSON.ARCH@GMAI L.COM 1250 EVERGREEN DRIVE CUTCHOGUE, NY 11935 PHONE: 631.513.6589 Town of Southold-Building Department October 15, 2023 53095 Main Road Page 1 of 1 PO Box 1179 Southold NY 11971 Re: Endless Round Golf 7785 Main Road Mattituck, N.Y. 11952 OCT 1 7 2023 District-1000, Section-122, Block-6, Lot-29.1 RLII.DING DEPT. Building Permit Number—49652 TOWN Inspection — Fire Separation In September, 2023, 1 inspected the construction for the alterations at the noted location. The inspection covered the fire separation between Building Occupants, Endless Round Golf(Type A-3 Occupancy) & Building Owner's Office (Type B Occupancy). The inspection results are: All walls & ceilings separating the two occupants are rated for 2- hours. This fire separation is composed of(2) layers of 5/8" Type X Gypsum Board, non load bearing wood studs, Rockwool Batt Insulation & (1) layer of 5/8" Type X Gypsum Board. Result— Based upon inspection of this project and to the best of my knowledge, belief and professional judgment, construction as installed complies with the plans and applicable codes of the IRC, NYS and Southold Town Building Codes. ZACKERY E. NICHOLSON, RA �ERED ARC E.N1q'y'T�Ca G 00 N Z i STgT 04g42'5 -AO F OF NEVJ ZACKERY E. NICHOLSON, RA Al ZEN ICHOLSON.ARCH@GMAI L.COM 1250 EVERGREEN DRIVE CUTCHOGUE, NY 11935 PHONE: 631.513.6589 Town of Southold-Building Department October 15, 2023 53095 Main Road Page 1 of 1 PO Box 1179 Southold NY 11971 Re: Endless Round Golf u�� 7785 Main Road Mattituck, N.Y. 11962 District-1000, Section-122, Block-6, Lot-29.1 OCT 1 7 2023 Building Permit Number—49652 BUILDING DEPT Inspection — Rough Plumbing rs1'!" ITTVir a.zr In September, 2023, 1 inspected the construction for the alterations at the noted location. The inspection covered the interior plumbing roughing for the Drainage Waste and Vent System (DWV) and the Water Supply System (WS) for the new ADA Bathroom. The inspection results are: 1 — DWV—System was fully exposed and readily viewed. I observed all drainage and vent lines. System constructed as required. New installation is connected to the existing system. All construction was done in compliance with the applicable sections of the IRC, NYS and Town of Southold Building Codes. 2 —WS— System was fully exposed and readily viewed. I observed all hot and cold water supply lines. System constructed as required. All construction was done in compliance with the applicable sections of the IRC, NYS and Town of Southold Building Codes. Result— Based upon inspection of this project and to the best of my knowledge, belief and professional judgment, construction as installed complies with the plans and applicable codes of the IRC, NYS and Southold Town Building Codes. ZACKERY E. NICHOLSON, RA ��RED Ape N�Cho�TF NT Z i 04444.5 QA- qTB OF N0`t'� y0 COMMENTS MELD INSPECTION REPORT DATE � ro FOUNDATION (IST) p� a I � -------------------------- FOUNDATION (2ND) 3m Lj � O ROUGH FRAMING& y PLUMBING (V �O r INSULATION PER NY, H STATE ENERGY CODE rlb FINAL a v ADDITIONAL COMMENTS �p Z3 7:4cot 4 toeo3- c. (e e* 1655 $tiara �D . o Cl 2.3 177 *1) YG J 3 U •2a S o� fi✓ r m O z • � x 0 m ro a �frn h Ao0 suFratrOoo: TOWN OF SOUTHOLD—BUILDING DEPARTMENT y� Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 © �y�* �aa Telephone (631) 765-1802 Fax (631) 765-9502 https://wwwsoutholdtownnV, .eOV Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only '''" l VI I� V AR 1 PERMITNO. �(/` Building Inspector: JUNI 7 ,1, 2023 1 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an rL;LDTAIG DEPM Owner's Authorization form(Page 2)shall be completed. Date: Z 3 OWNER(S)OF PROPERTY:Name: 77c35 A l(A l 9,3 SCTI'M#1000- -")-2 z- ( � ZT• ) Project Address: '7765 Mp (n 9 ' , Maik 6cV /" ( (q Phone#: Email: Mailing Address: P - 0 e)ft 5L4-7 La.v feA Nv ' I riq g, CONTACT PERSON: PK - MUv rt-- Name: Gtj- moo Tt- Mailing Address: 5-(O .0 a I&A, M Phone#: 01- 76 - q-5-S0 Email: CMdOYe (E, A4DO"t'� . s DESIGN PROFESSIONAL INFORMATION: Name: 7L } E✓5 Mailing Address: Phone#: (P% 513 u Email: nl aaat ) nk) "I- cG''1t II�� 1 O ate' 3 U s In 5 --Tke less R-Cad Name: 'DGtM �- 6( CJ1M /L -, Q-t (�{ ( l Mailing Address: C/o (020 AkU(yl Q•r ..__J Ottk IC 1 /V,/ f 10 Phone#: (031- 7 -3� Email: don DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: l!"ther $ Will the lot be re-graded? ❑Yes [k0 Will excess fill be removed from premises? Dyes ONO 1 PROPERTY INFORMATION Existing use of propert : 5 Intended use of property: Fslao-', Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to B this property? ❑YesrKNo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by hapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): k V't U C.(V C9t)-y-e "authorized Agent ❑Owner Signature of Applicant: . Date: STATE OF NEW YORK) SS: COUNTY OF 1V_) 60- VM(klre being duly sworn, deposes and says that(s)he is the"a* (Name of individual signing contract) above named, (S)he is the -F-I�L�>"/L� 1 (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application f' a herewith. Sworn before me this 2—day day of 20 nary P blic B 1099 tNS Notary Public,State of New Ydi k PROPERTY OWNER AUTHORIZATIOIWo.01PE6'I$06ss (Where the applicant is not the a hied in Suffolk Coun�l rr _ f ssion Expires July 18. Z_ rreeliding at jLs!� mt� f Vl (2oo �, m agg 4 dc_ do hereby auC.I.LA,thorize e Rk C QO`✓'f to apply on my behalf to thee Town of Southold Building Department for approval as described herein. owner's Signatu -.J-gj ate M�Q i'IIP�//!Gi' 11f Print Ow is Name 2 Q�Suteott°O , TOWN OFSOUTHOLD-FIRE MARSHAL ag 54375 MAIN ROAD P. O.BOX 11791 SOUTHOLD,NY 11971-0959�, I: "_, �✓ �yMO`t OFFICE(631)765-1802 FAX(631)765-9502 / V 1 �023 FIRE ALARM SYSTEM CERTIFICATE OF-FITNESS'AND TESTING WARNING:NOTIFY.ALL OCCUPANTS,AND ANY AGENCIES WHO MIGHT'RESPOND BEFORE TESTING SYSTEM., FAILURE TO DO SO MAY RESULT IN LEGAL"ACTION AGAINST THE INSPECTOR ESTABLISHMENTNAME: EF()atess.__CVI-p__..____..._.________._ . __ ..___,..___ DATE: ...._P.._.._......... __.-.__ _ ._... 1�, ..__. _. AnnleESS -7 8s-Mazn'I� _�� i�yUC�C — qS2 EFfBAeE�➢fISTR1CT�shol--- -l� i NAME OF OWNER/AGENT PRESENT: y-y�y]mi 1 _I b (1 �.,p(jp� HA O UP O CY CHANGED SINCE LAST VISIT?^^ NATUREOFINSPECIIO /TESTIN `%,• ANTE: (� 7�J'` NAME OF CENTRAL STATION_ PHONE#TO CENTRAL STATIONC17." TYPE OF SYSTEM: MANUAL❑ AUTOMATIC 0 VOICE EVACUATION❑ OTk1ERRO CENTRAL STATION.,( REMOTE❑ PROPRIETARY❑ AUX❑ Carbon Monoxide Integrated_ Yes ❑ No LIST ANY/ALL➢EFICIENCIES WERE THESE DEFICIENCIES CO .YES O IF NOT,WHY? CERTIFICATION: LAN EMPLOYEE OF THE INSPECTING FIRM LISTED BELOW,DO-HEREBY CERTIFY THATTHE ALARM SYSTEM DESCRIBED ABOVE WAS INSPECTED,iN ACCORDANCE WITH THE'APPLICABLE PORTIONS OF NFPA 72(2016 VERSION),PARTICULARLY CHAPTER 7'AS WELL AS TABLE 10A.3&SECTION-10.6.2 OF NFPA 72.THIS CERTIFICATION DOES NOT IMPLY THAT ITEMS REQUIRING DAILY WEEKLY,MONTHLY,OR ` QUARTERLY INSPECTION OR TESTING WERE PERFORMED AT THE SPECIFIED INTERVALS,BUT DOES AMPLY ALL SUCH ITEMS WERE INSPECTED OR TESTED AND APPEAR TO FUNCTION AS NOTED IN THIS CERTIFICATION AT THE TIME OF INSPECTION.I CERTIFY THAT THIS INSPECTION HAS BEEN PROPERLY CONDUCTED AND ALL'OF,THE ABOVE STATEMENT'S ARE TRUE AND CORRECT TO TIHI,BEST,OF MY KNOWLEDGE. INSPECTING FIRM INFORMATION COMPANY NAME: NYS LICENSE NUMBER: COMPANY ADDRESS: J/U-DY�.LIIC — _ '{ .. PHONE:,_ l INSPECTOR'SNAME: SIGNATURE DATE: ORIGINAL COPY WITH SIGNATURE IS TO BE SUBMITTED TO THE TOWN OF SOUTHOLD FIRE MARSHAL. A COPY IS TO BE LEFT ON SITE AT THE FIRE ALARM PANEL. OFFICE USE ONLY: DATE RECEIVED MAINTENANCE INSTALLATION AND MAINTENANCE INSTRUCTIONS SYSTEM91 NOTE:Before performing maintenance on the detector,notify the proper au- thorities that maintenance is beingperformed and the system will be tempo-o- Y P ratify out of service. Disable the zone or system undergoing maintenance to / SENSOR® prevent any unwanted alarms. Power must be removed.fr,- ,.tbe A---_. )--j -�,:-•�,�, ,,,- mu_ - (/ j o before performing maintenance of any kind. - `T I - V•�V/ , \ 3/` 3825 Ohio Avenue,St.Charles,Illinois 60174 „'�� Rafe�ta.'a!^a• ' " ✓ Series Photoelectric Smoke Detectori� 800/736-7672,FAX:630/377-6495 1. Remove the detector cover by turning counterclockwtse. ,__�.--;;ire 6:)� -^t -•�.� - www.systemsensar.com 2. Vacuum the cover or use canned air to remove any dust or debris. Models: 2W-B,2WT-B,4W-B,4WT-B 3. Remove the top half of the screen/sensing chamber by lifting straight up ELECTRICAL SPECIFICATIONS 2-WIRE 4-WIRE (Figure 5). System Voltage-Nominal: 12/24 12/24 VDC Non-polarized 4. Vacuum or use canned air to remove any dust or particles that are pres- - Min.: 8.5 8.5 VDC ent on both chamber halves. Max.: 35 35 VDC 5. Replace the top half of the screen/sensing chamber by aligning the arrow Max.Supply Ripple Voltage: 30 30 °%peak to peak of applied voltage on the screen/sensing chamber with the arrow on the housing. Press Avg.Standby Current: 5o 50 IA average down firmly until the screen/sensing chamber is fully seated. Peak Standby Current: 100 —pA 6. Replace the detector cover by placing it over the screen/sensing chamber - Max.Alarm Current: 130 20 mA 12 Volt Systems and acetur theing it clockwise cover until it snaps into place. (For 2W-B and 2WT-B,panel must limit current) 130 23 mA 24 Volt Systems Min.Alarm Current _ IOmA — 7. Reinstall the detector and test. (See the Testing section.) Alarm Contact Ratings: — 0.5 Amp®30 V AC/DC 8. Notify the proper authorities when the system is back in service. Alarm Reset Time: 0.3 0.3 sec FIGURE S.REMOVING/REPLACING SCREEN/SENSING CHAMBER Max.Start-up Capacitance: 0.1 —pF Latching Alarm:Reset by momentary power interruption - t—REMOVABLE t Maximum hill Start-up Time: 45 15 see OETECrOR Alarm Verification Start-up Time': 15 IS sec cil coven 'Assumes the panel's alarm verification reset time is 10 seconds or less.Should the alarm verification reset exceed 10 seconds,use the maximum initial start-up time. PHYSICAL SPECIFICATIONS Heat Sensor(Model 2WT-B and 4WT-B ; ry \135°F(57.2°C) �. SCREEWSENSING - - -- --- Freeze Trouble(Modet2�VTkTan •4 \// 1°F(5°C) CHAMBER Operating Temperatue-R�4$ \Il ROP HALF) 2W-B and 4W-B: r'' / : .J 32 to 120°F(0 to 49°C) 2WT-B and 4WT-B:^, -'32 to 100°F(0 to 37.8°C) Operating Humidity5lariget NO\j 1 2023 0 to 95%RH non-condensing Storage Temperature Range: -4 to 158°F(-20 to 70°C) Diameter(including base): 5.3 inches(13.5 cm) Height(including base): - - - --' 2.0 inches(5 cm) .DEfECTOR HOUSING Weight: ''; ° -. 6.3 oz.(178.6 g) 50136-00 BEFORE INSTALLING detector to be easily installed or removed.The mounting base installation is - Please read thoroughly System Sensor's Applications Guide for System Smoke further simplified by the incorporation of features compatible with drywall Detectors(SPAG91),which provides detailed information on detector spacing, fasteners. placement,zoning,wiring,and special applications.This manual is available Two LEDs on the detector provide a local visual indication of the detector's status: online at www.systemsensor.com. (See link at bottom of page 4.) NOTICE:This manual shall be left with the owner/user of this equipment. TABLE 1.DETECTOR LED MODES IMPORTANT.This detector must be tested and maintained regularly following :BlinklO Red LED NFPA 72 requirements.At a minimum,cleaning should be performed annually. Power-up Blink 10 sec GENERAL DESCRIPTION Normal(standby) — Models 2W-B and 2WT-B are 2-wire photoelectric smoke detectors; models Out of sensitivity Blink 5 sec FCC STATEMENT 4W-B and 4WT-B are 4-wire photoelectric smoke detectors. All models in- Freeze Trouble Blink 10 sec This device compiles with part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)This device may not cause harmful interference,and(2)this device must corporate a state-of-the-art optical sensing chamber and an advanced micro- Alarm Solid accept any interference received,including interference that may cause undesired operation. processor.The microprocessor allows the detector to automatically adjust its After an initial power-up delay, the red and green LEDs will blink synchro- Note: This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules.These limits are designed to provide sensitivity back to the factory setting when it becomes more sensitive due to nously once every ten seconds.It will take approximately 80 seconds for the reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and,if not installed and used contaminants settling in its chamber.In order for this feature to work prop- detector to finish the power-up cycle(see Table 2). in accordance with the instructions,may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular instal- erly,the chamber must never be opened while power is applied to the smoke lotion. If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to detector.This includes cleaning,maintenance or screen replacement.Should TABLE 2.POWER-UP SEQUENCE FOR LED STATUS INDICATION* try to correct the interference by one or more of the following measures: it become necessary, the screen/sensing chamber is field replaceable. Mod- Condition Duration -Reorient or relocate the receiving antenna. els 2WT-B and 4WT-B also feature a restorable, built-in, fixed temperature -Increase the separation between the equipment and receiver. Initial LED Status Indication 80 seconds -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (1 condition if the thermal detector and are also Capable of sensing a freezeLED -Consult the dealer or an experienced radio/TV technician for help. condition if the temperature is below 41°F(5°C) (i Initial excessive Status Indication 4 minutes p (if excessive electrical noise is present) All ie Series detectors are designed to provide open area protection.7tvo-wue. SUPPLEMENTAL INFORMATION models must be used with compatible UL Listed panels only. The MOD2W -Refer to Electrical Specifications for start-up time in conjunction with panel ' Q -0 0 o installation manual is available on-line at www.systemsensoccom. I alarm verification. For the latest warranty information,please go to: When used with an is Series compatible control panel or the i'Series MOD2W http-n wsvattmsensorcom/en-us/Documents/E56-4000.pd - . NOTE:If.e during power-up,the detector determines there is excessive eof the For Limitations of Fire Alarm Systems,please go to: module(see installation manual wide signal. the 2 he and 2WT-B ca are capable rat noise in the system such as[hose caused by improper grounding of the htto-//w s t ensorcom/en-us/Documents/156-155B.odf of generating a "maintenance needed" signal. The MOD2W can indicate a system or the conduit,both LEDs will blink for up to 4 minutes before display- For •❑' _ need for cleaning, replacement, or a freeze condition [2WT-B only) at the in detector status. (See Table 2. For the Smoke Detector Application Guide,please go to: g ) ' h"ttnc//wmiiyatemsensor.cam/en-us/Documents/System Smoke Det- control panel or module. Warranty Limitations of Smoke Detectors Installation of the 2W-B,2WT-B,4W-B,and 4WT-B detectors is simplified by After power-upsit has completed and the detector o functioning normally within edors AmnGuide SPAG91.odf its listed sensitivity range,the green LED blinks once eve five seconds.If the We Fire Alarm Systems Applications Guide the use of a mounting base that may be pre-wired to the system,allowing the Y g ' every Rand rnarRand Syc an rn Sensorsis a rellstereessed rlwa. detector is m need of maintenance because its sensitivity has shifted outside ?is a trademaM end System SenwP is a rerystered betlemade N Hmeyxetl INematianal,Inc. 4 156-0130-000 1 156-0130-000 02020 System Sensor.7/8/2020 7/8/2020 the listed limits,the red LED blinks once every five seconds.When the detec- 2-WIRE P DETECTOR WIRED IN STYLE D CONFIGURATION B.SMOKE ENTRY TEST for is in the alarm mode,the red LED latches on,The LED indication must not ACAl1TION Canned aerosol simulated smoke (canned smoke agent) may be used for be used in lieu of the tests specified under Testing.In a freeze trouble condi- Smoke detectors are not to be used with detector guards unless the combina- smoke entry testing of the smoke detector.Tested and approved aerosol smoke tion,the red LED will blink once eve 10 seconds. See Table 1.) tion has been evaluated and found suitable for that purpose. ACAl1TION every ( products are: To measure the detector's sensitivity, the P Series Model SENS-RDR Infrared IMPORTANT PRODUCT ADVISORY Sensitivity Reader tool should be used.(See Figure 4.) ^r? manual, WIRING INSTALLATION GUIDELINES Style D Initiating Device Circuits and 2-wire P Smoke Detectors: ' MODEL I56-1801,is available on-line at wwmsystemsensor.com All wiring must be installed in compliance with the National Electrical Code, Any 2-wire i3 smoke detector (2W-B,2WT-B, 2W7A-B,or 2WTR-B) wired in •- Home _ tries 25S,30S Models 2W-B and 2WT-B also include an output that allows an optional Model applicable state and local codes, and any special requirements of the local the Style D initiating device circuit (IDC) configuration requires the use of a SDi CHEK02 and CHEK06 Authority Having Jurisdiction. MOD2W module.This is because fire alarm control panels vary by manufac- MOUN Remote Annunciator to be connected. y g turer on the implementation of Style D circuits. Therefore, the only way to SIB SOLOA4 Proper wire gauges should be used. The conductors used[o connect smoke MOUNTING insure proper operation of 2-wire 13 smoke detectors(2W-B,2WT-B,2WTA-B, s detectors re the alarm control panel and accessory devices should io color- SDi SMOKESABRE-01 Each i Series detector is supplied with a mounting base that can be mounted: coded to reduce the likelihood of wiring errors. Improper connections can or 2WTR-B) on Style D IDC's is to use a MOD2W module.For Style D wiring 1. To a single gang box,or prevent a system from responding properly in the event of a fire. diagrams, refer to the MOD2W installation manual (156-1800, available for When used properly,the canned smoke agent will cause the smoke detector 2. To a 3V2inch or 4-inch octagonal box,or download from the System Sensor website www.systemsensoncomJ, to go into alarm.Refer to the manufacturer's published instructions for proper 3. To a 4-inch square box with a plaster ring,or The screw terminals in the mounting base will accept 14-22 gauge wire.For use of the canned smoke agent. 4. Direct mount or to ceiling using drywall fasteners. (See Figure 2.) best system performance,all wiring should be installed in separate grounded conduit;do not mix fire alarm system wiring in the same conduit as any other INSTALLATION AGAUTIGIN FIGURE 1.DETECTOR MOUNTING electrical wiring. ltvisted pair may be used to provide additional protection AWARNING Canned aerosol simulated smoke (canned smoke agent) formulas will vary against extraneous electrical interference. Remove power from alarm control unit or initiating device circuits before in- by manufacturer. Misuse or overuse of these products may have long term O Wire connections are made by stripping approximately 1/4-inch of insulation stalling detectors. adverse effects on the smoke detector.Consult the canned smoke agent Mann- from the end of the feed wire,inserting it into the proper base terminal,and facturer's published instructions for any further warnings or caution state- tightening the screw to secure the wire in place. NOTE:To install units so that corresponding LEDs are lined up, refer to the ments. TWO-WIRE COMPATIBILITY "Green LED"indicator on the base. System Sensor two-wire smoke detectors are marked with a compatbbil- 1. Wire the mounting base screw terminals per Figure 3a or Figure 3b, as I C.DIRECT HEAT METHOD(MODELS 2WT-B AND 4WT-B ONLY) ity identifier located on the label on the back of the product. For two-wire applicable. Using a 1000-1500 watt hair dryer,direct the heat toward either of the thermis- models 2W-B and 2WT-B, connect detectors only to compatible alarm con- 2. Place detector on the base and rotate clockwise.The detector will drop tors.Hold the heat source about 12 inches from the detector to avoid damage Vol panels as identified by System Sensor's compatibility chart available at to the plastic. 50121-00 into the base and lock into place with a"click". www.systemsensoncom. NOTE:For the above tests,the detector will reset only after the power source The P Series heads and bases are keyed so that a 2-wire head will only mount 3. After all detectors have been installed,apply power to the alarm control y WIRING DIAGRAMS unit, has been momentarily interrupted. - h a s and base, and a ly identified head will only mount to a 4e.W base.The If a detector fails any of the above test methods,its wiring should be checked heads and bases are clearly identified as either 2-wire or 4-wire.When mount- FIGURE 3A.WIRING DIAGRAM,2W-B AND 2WT-B 4. Test each detector as described in Testing. and it should be cleaned as outlined in the Maintenance section.If the detec- ing the i3 Series,ensure that the head is mounted to the correct base. S. Reset all the detectors at the alarm control unit. for still fails,it should be replaced. TAMPER-RESISTANCE FEATURE 2-WIRE. SOL 6. Notify the proper authorities that the system is in operation. Notify the proper authorities when the system is back in service. The P Series detectors include a tamper-resistance feature that prevents re- ZONE — RESISTOR moval from the mounting base without the use of a tool.To engage the tam- ACAUTION LOOP VERIFICATION(MODELS 2W-B AND 2WT-B ONLY) per-resistance feature,cut the small plastic tab located on the mounting base 0.°100Z �10°T Dust covers are an effective way to limit the entry of dust into the smoke de- Loop verification is provided by the EZ Walk loop test feature.This feature is (Figure 2),and then install the detector.To remove the detector from the base rector sensing chamber. However,they may not completely prevent airborne for use with i3 Series compatible control panels or the P Series MOD2W mod- once it has been made tamper resistant,use a small screwdriver to depress the dust particles from entering the detector. Therefore, System Sensor recom- ule only.The EZ Walk loop test verifies the initiating loop wiring and provides i 0 OOOOO visual status indication at each detector. square tamper release tab,located on the skirt of the mounting base,and[urn E =slaza mends the removal of detectors before beginning construction or other dust 2-WIREthe detector counterclockwise. coNrROL g = o - ggproduang activity. When returning the system to service, be sure[o remove 1. Ensure proper wiring and power is applied.Wait approximately six min- PANEL ' the dust covers from any detectors that were left in place during construction. Dies before perfomdng EZ Walk test. FIGURE 2.TAMPER-RESISTANCE FEATURE 2. Place control panel or module in EZ Walk Test mode. (See panel manu- 2WT-1313 facturer's manual or MOD2W manual.) ADIORUICT MOUNT 2NT-B TESTING ES ® S0133-01 Detectors must be tested after installation and following maintenance. 3. Observe the LEDs on each detector: NOTE:Before testing,notify the proper authorities that maintenance is being TABLE 3.EZ WALK TEST DETECTOR MODES FIGURE 3B.WIRING DIAGRAM,4W-B AND 4WT-0 performed and the system will be temporarily out of service.Disable the zone Green LED Red LED or system undergoing maintenance to prevent any unwanted alarms. AUX OR 4 y Ensure proper wiring and power is applied.After power up, allow 80 seconds Proper Operation Double blink 5 sec — SMOKE POWER - for the detector to stabilize before testirzg. Out of Sensitivity — Double Blink 5 sec Test i3 Series detectors as follows: Freeze Condition — Double Blink 10 sec IOC ,NAPOFFTAB A.TEST SWITCHOR TAMPER LOCK NOTE:The EZ Walk loop test must not be used instead of alarm testing. 1. An opening for the recessed test switch is located On the detector hous- RELEASE TAB S0226-00 0 0 0 0 0 ing. (See Figure 4.)4-WIREDO NOT INSTALL DETECTORS IN THE FOLLOWING AREAS: CONTROL r € 2. Insert a small screwdriver or allen wrench (0.18- max.) into the test In or near areas where articles of combustion are normall PANELswitch o enin ush and hold. • p y present p g psuch as kitchens;in garages (vehicle exhaust);near furnaces,hot water 4WB or 3. If the detector is within the listed sensitivity limits,the detector's red LED heaters,or gas space heaters. 4WrI3 -o1 should light within five seconds. • In very cold or very hot areas. FIGURE 4.RECESSED TESTSWITCH OPENING AND SENS 1DR POSITION • In wet or excessively humid areas,or next to bathrooms with showers. • In dusty,dirty,or insect-infested areas. #MS=NS.S_R0R AN.OIEONTHE• Near fresh air inlets or returns or excessively drafty areas.Air condition- & R ORATTRE ers, heaters, fans, and fresh air intakes and returns can drive smokemerLxono-um- away from the detector. Consult NFPA 72, the local Authority Having Jurisdiction (AHJ),and/or ap- plicable codes for specific information regarding the spacing and placement of smoke detectors. LED vusD $WRRNA o, DUMEreRTooE ' - RELESSEDTESTSWRLH S0135-00 2 156-0130-000 3 156-0130-000 7/8/2020 7/8/2020 Limitations of Fire Alarm Systems „ r Manufacturer recommends that smoke and/or heat detectors be Heat detectors do not sense particles of combustion and located throughout a protected premise following the rec- are designed to alarm only when heat on their sensors in- ommendations of the current edition of the National Fire crease at a predetermined rate or reaches a predetermined Protection Association Standard 72,National Fire Alarm Code level.Heat detectors at e designed IQ protect Property,not (NT®73),manufacturers recommendations,stale/provincial 11L and local codes,and the recommendations contained in Guide • Warning devices(including horns,sirens,and bells)may for the proper Use of System Smoke Detectors,which is made not alert people or wake up sleepers who are located on available at no charge to all Installing dealers.In Canada refer the other side of closed or partially open doors A warn- to CAN/ULC-S524"The Standard for the Installation Of Fire ing device that activates on a different floor or level of Alarm Systems".A study by the Federal Emergency Manage- a dwelling or structure is less likely to awaken or alert ment Agency(an agency of the United States government) people.Even persons who are awake may not notice the indicated that smoke detectors may not go off or give early warning if the alarm is muffled by noise from a stereo, warning in as many as 35% of all fires While fire alum radio,air conditioner or other appliance,or by passing systems are designed to provide wanting against fire,they do traffic.Audible warning devices may not alert the hearing- not guarantee warning or protection against fire.Any at impaired(strobes or other devices should be provided to system is subject to comoronise or failure to warn for a ymaw warn these people).Any warmng device may fail to alert of reasons.For example: people with a disability,deep sleepers,people who have • Particles of combustion or"smoke"from a developing fie recently used alcohol or drugs,or people on medication may not reach the sensing chambers of the smoke detector or sleeping pills. because: " -Please note that- Barriers such as closed or partially closed doors,walls, I)Strobes can, under certain circumstances, cause or chimneys may inhibit flow. seizures in people with conditions such as epilepsy. - Smoke particles may become"cold"and stratify,and tn)Studies have shown that certain people,even when may not reach the ceiling or upper walls where deice- they hear a fire alarm signal,do not respond or tors are located. comprehend the meaning of the signal.It is the Smoke particles may be blown away from detectors by property owner's responsibility to conduct fire drills air cutlets. and other training exercises to make people aware Smoke particles may be drawn into au returns before of fire alarm signals and instruct on the proper reaching the detector. reaction to alarm signals. In general,smoke detectors on one level of a structure cannot fit)In rare instances,the sounding of a warning device be expected to sense fires developing on another level. can cause temporary or permanent hearing loss. • The amount of"smoke"present may be insufficient to alarm , Telephone lines needed to transmit alarm signals from smoke detecors Smoke detectors are designed to alarm at various levels of smoke density.If such density levels are a premises to a central station may be out of service or not created by a developing in at the location of detectors, temporarily out of service.For added protection against the detectors will not go into alarm. telephone line failure,backup radio transmission systems • Smoke detectors,even when working properly,have sens- are recommended. ing Nnitaflons.Detectors that have phomelectromc sensing • System components,though designed to last many years, chambers tend to detect smoldering fires better than flaming can fail at any time.Asa precautionary measure,itisrec- fires,which have little visible smoke.Detectors that have ommended that smoke detectors be checked,maintained, ionizing-type sensing chambers tend to detect fast Naming and replaced per manufacturer's recommendations. Cues better than smoldering fires.Because fires develop in ' System components will not work without electrical different ways and are often unpredictable in their growth, power. If system batteries are not serviced or replaced neither type of detector is necessarily best and a given type regularly,they may not provide battery backup when AC of detector may not provide adequate wanting of a file. power fails. • Smoke detectors are subject to false alarms and nuisance • Environments with high air velocity or that are dusty or alarms.For example,a smoke detector located in or near a dirty require more frequent maintenance. kitchen may go into nuisance alarm during normal operation t of kitchen appliances.In addition,dusty or steamy env iron- In general,fire alarm systems and devices will not work ments may rouse a smoke detector to falsely alarm.If the without power and ill t function 1 1 they location of a smoke detector causes an abundance of false re maintained and tested re larly. alarms or nusance alarms,do not disconnect the smoke While installing a fire alarm system may make the owner detector,call a prof ssitm l to spalvze JhQ giluglign and eligible for a lower insurance rate,an alarmt t recommend a solution, substitute for insurance.Property owners should continue • Smoke detectors cannot be expected to provide adequate to act prudently in protecting the premises and the people warring of fires caused by arson,children playing with in the premises and should properly insure life and property matches(especially within bedrooms), smoking in bed, and buy sufficient amounts of liability insurance to meet violent explosions(awed byescaping gas,improper storage their needs. of flammable materials,etc.). 1 15 g5/29/229/2m8 I Requlrem®nts and recommendations • AB fire at=systems require notification devices,indud. for proper use of fire alarm systems ing sirens, bells, horns, and/or strobes. In residential p p y applications,each automatic alarm initiating device when Including smoke detectors and other fire activated shall cause the operation of an alarm notification alarm devices' device that shall be clearly audible in all bedrooms over ambient or background noise levels(at least 15dB above Early fire detection is best achieved by the installation noise)with all intervening doors closed. and maintenance of fire detection equipment in all moms • It is recommended that a smoke detector with an integral and areas of the house or budding in accordance with the sounder(smoke alarm)be located in every bedroom and requirements and recommendations of the current edition an additional notification device be located on each level of the National Fire Protection Association Standard 72, of a residence. National Fire Alarm Code(NFPA 71),the manufacturer's Tokeep you fire alarm system in excellent working order, recommendations, stale/provincial and local codes, and ongoing maintenance is required per the manufacturer's the recommendations contained in Cu'de for the Prep gr recommendations and UL/ULC and NFPA standards.At Use or Sicilern Smoke Detectors which is made available a minimum the requirements of Chapter 7 of NFPA 72 at no charge to all installing dealers. In Canada refer to shall be followed. In Canada refer to CAN/ULC-S536 CAN/IILC-S524"The Standard for the Installation Of Fire "The Standard for the Inspection and testing Of Fire Alarm Systems'.For specific requirements,check with the Alarm Systems'.A maintenance agreement should be local Authority Having Jurisdiction(ex.Fire Chief)for fire arranged through the local nunufatturer's representative. protection systems. Maintenance should be performed annually by authorized personnel only. Requirements and Recommendations include: • The most common cause of-an alarm system not firm- • For residential applications, smoke detectors shall be finning when a fire occurs is inadequate maintenance.As installed outside of each separate sleeping area in the im- such,the alarm system should be tested weekly to make mediate vicinity of the bedrooms and on each additional sure all sensors and transmitters are working properly. story of the family living unit,including basements and Although designed for long life, fire alarm devices excluding crawl spaces and unfinished aides. including smoke detectors may fad at any nine. It is • Smoke detectors shall be installed in sleeping roomsin new recommended that residential smoke detectors shall be construction and it is recommended that they shall also be replaced every 10 years. installed in sleeping moms in existing construction. ' wireless smoke detectors that are used in one- and • It is recommended that more than one smoke detector shall two-unit family dwellings may be used as long as the be installed in a hallway if it is more than 30 feet long. detectors are being monitored,tested,and maintained. • It is recommended that there shall never be less then two Once the detector is no longer part of a listed fire alarm smoke detectors per apartment or residence. system monitoring program,it is recommended that it be •It is recommended that smoke detectors be located in any replaced prior to 10 years from the date of manufacture room where an alarm control is located,or in any room per recommended practice of NFPA 72. where alarm control connections to an AC source or phone Any smoke detector,fire alarm system or any component lines are made.If detectors are not so located,a fire within of that system which fails shall be repaired or replaced the room could prevent the control from reporting a fire. immediately. Typical System Installations per NFPA 72 o ■o DI ONO KITCHEN DE ROOM BFDPWM NPOOM YJTCHEN OleNO saN0 ■O O ■ 6EO N O ■ WINO goOM ■ EDPM ■O ■O ro 9EaP00M as 9EpgOOM LNIN0 ROOM aEDg00M HOUSENPE'a• O ■ . DEDfl00M �R�. ■O aNUOE Xa114ETYPE•p• WINa • aaSro ROOM DOOR ■ ■-smoke Dewato.re9klrea wsEUENr ■O-Smoke Detectors required with loWspal sounders remmmendod HOUSE[ E-C' ♦-Heal dNvated Detectors required ❑-Smoke Dateotom for additional Protectlon 0-Naafloation Devices Ie001-OD As of May 2018,this document supersedes any previous liability Information enclosed with this product. 2 1561558_00 05/29/2018 i 1 Important Product Advisory: Style D initiating Devices Circuits and 2-wire 13 Smoke Detectors Refer to installation manual for required wiring of 2-wire i3 smoke detector (2W-B, 2WT-B, 2WTA-B, or 2WTR-B) in the style D initiating device circuit configuration. 156-2719-00 BOARD MEMBERS Southold Town Hall Leslie Kanes Weisman, Chairperson 53095 Main Road•P.O.Box 1179 Patricia Acampora Southold,NY 11971-0959 Eric Dantes Office Location: Robert Lehnert,Jr. Town Annex/First Floor Nicholas Planamento �� 54375 Main Road(at Youngs Avenue) ly�oU , Southold,NY 11071 RECEIVED http://southoldtownny.gov 4, V G ZONING BOARD OF APPEALS „JUN z TOWN OF SOUTHOLDJ Q Tel.(631)765-1809 Southold Town Cleric FINDINGS,DELIBERATIONS AND DETERMINATION MEETING OF NNE 15,2023 ZBA FILE No.: 7795SE NAME OF APPLICANT: The Endless Round,LLC/7785 Main Road Realty,LLC PROPERTY LOCATION: 7785 Main Road,Mattituck NY SCTM: 1000-122-6-29.1 ' SEORA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions,without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated March 28, 2023 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. LWRP DETERMINATION: The relief,permit,or interpretation requested in this application is listed under the Minor Actions exempt list and is not subject to review under Chapter 268. PROPERTY FACTS/DESCRIPTION: Subject 49,585 square feet, 1.13 acre parcel, located in the B(Business) Zoning District measures 126.79 feet along Main Road(a.k.a.State Route 25),then runs north 401.61 feet along a commercially developed parcel to the west,then runs127.37 feet east,along the same commercially developed parcel, and returns 382.96 feet south to the roadway along a commercially developed parcel to the east. The subject property is improved with a two-story frame office building, roof over open porches, brick pathways, access stairs to cellar entrance, asphalt pavement entrance drive and labeled parking spaces, various electric transformers, multiple air condenser units, parking area lamp posts, a metal 'walkway' connecting the subject property rear parking lot with the adjacent lot to the east's parking lot, and an elevated tennis court enclosed by fencing,as shown on the survey by Nathan Taft Corwin,III,Land Surveyor and dated April 27,2022. BASIS OF APPLICATION: Applicant requests a Special Exception under Article III, Section 280-48B(6) to establish and operate a fully enclosed commercial recreation facility;at:7785 Main Road,Mattituck,NY. SCTM No. 1000-122-6-29.1. RELIEF REQUESTED: The applicant proposes altering the use of a Town of Southold Planning Board approved commercial office building to a fully enclosed recreational membership facility golf simulator. ADDITIONAL INFORMATION: The Town of Southold Planning Board approved a site plan for the use as a commercial office building(newspaper building)in 1991;the Planning Board has indicated that an updated site plan is not necessary since the proposed alterations are limited to the use,and interior improvements which will Page 2,June 15,2023 #7795SE,The Endless Round,LLC/7785 Main Road Realty,LLC SCTM No. 1000-122-6-29.1 be reviewed when a building permit is filed with the'Town,of Southold Building Department for interior alterations. No alterations of the exterior of the building,parking areas,access paints or to the raised tennis court are proposed by the applicant. Town of Southold Zoning Code,for the B (Business) zone allows the proposed use by Special Exception. Improvements on the subject parcel are covered by Certificate of Occupancy#Z-16874,dated May 16, 1988 for the construction of a`newspaper building'. The parcel is also the beneficiary of two prior decisions of this Board, #4069 dated December 16, 1991 permitting exterior lighting at the raised tennis platform with conditions and file #3420 dated December 20,1985 creating the lot as part of a subdivision where insufficient lot width exists. The applicant/tenant provided floor plans and a parking and site plan labeled A-1, A-2, & SP-1, prepared by Zackery E.Nicholson,Registered Architect and dated February 22,2023. The applicant proposes to establish four(4)golf simulator`bays' as Phase I of the interior alterations followed by Phase 2(at an unknown date)establishing an additional 4 golf simulator`bays:' During Phase 1 the property owner will maintain a private office in the future expansion area. The applicant has provided in excess of 25 parking spaces for the facility's patrons and employee use. An immediate neighbor addressed the Board during the public hearing relative to the raised platform tennis located at the rear of the subject-site. They indicated that the tennis platform was built encroaching on their property, by approximately 1.5 feet at one corner and its use is limited by ZBA decision 94069 in that exterior lighting may not extend after 1 Opm and that the improvement cannot be used commercially. The applicant stated that they have no intention of using the tennis court as part of their golf simulator business, that their business will be confined to the interior of the building,and that the platform tennis court was built with a valid Town of Southold Building permit and can continue to be used by the property owner and tenant. No other member of the public or an immediate neighbor spoke in favor of or against this application. FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on June 1,2023 at which time written and oral evidence were presented. Based upon all testimony,documentation, personal inspection of the property and surrounding neighborhood,and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: The Board has reviewed the General Standards governing Special Exception uses set forth in Section 280-142 and finds: A. That the use will not prevent the orderly and reasonable use of adjacent properties or of properties in adjacent use districts. The existing building is approximately 6,400 square feet (footprint) and was constructed in 1998 for The Suffolk Times/News Review newspapers. The exterior of the building will not change or be altered in anyway;however,the interior will be reconfigured as follows: approximately 4,000 square feet to accommodate 4 separate golf simulator bays/partitions and a common area serving as a lobby, lounge and general congregation area. B. That the use will not prevent the orderly and reasonable use of permitted or legally established uses in the district wherein the requested use is located or of permitted or legally established uses in adjacent use districts. The property is zoned B and surrounded by commercial uses. The proposed recreational use will not interfere with the commercial uses in the district or in the surrounding area. The building is large with surrounding open space and generous setbacks. The building was constructed with 33%landscaping and only 13%lot coverage. The recreation use will operate generally after hours on the weekday(after work) 1 Page 3,June 15,2023 #7795SE,The Endless Round,LLC/7785 Main Road Realty,LLC SCTM No. 1000422-6-29.1 and on weekends. The proposed operation will not interfere with the surrounding businesses. The surrounding buildings are medical and professional office buildings which have limited office hours and are generally closed on the weekend. The medical offices operate with scheduled appointments. The recreational use is inside the building and the building has sufficient parking,as evidenced in the Town of Southold Planning Board approved site plan and based on individual Board members site inspection. C. That the safety,"the health,the welfare,the comfort,the convenience, or the order of the town will not be adversely affected by the proposed use and its location. The use is a benefit to the community. Indoor recreational activities are very limited in Southold Town. The proposed use is an individual and household activity. The owners hope to coordinate with the local school's golf teams for practice and training during inclement weather. Community programs would be pre-scheduled and not adversely affect the Town at large. D. That the use will be in harmony with and promote the general purposes and intent of this chapter. As a Special Permit use,the use will be in harmony with the B zoning. Indoor recreational activities are generally welcomed in the community. This use is intended for individuals,households and friends to enjoy wholesome social/sport activities. There are no age restrictions for simulator golf. E. That the use will be compatible with its surroundings and with the character of the neighborhood and of the community in general, particularly with regard to visibility, scale and overall appearance. The existing building was designed and constructed for a newspaper(Suffolk Times)and has been unoccupied since the newspaper relocated elsewhere in Mattituck. The building is perfect for the proposed recreational use— offering high ceilings, extensive space, and good ventilation. The existing interior, as proposed to be partitioned for the golf simulators in private 17 feet by 18 feet areas, will maintain separate areas and the overall peace and quiet of the larger space identifying its unique bamlike design. F. That all proposed structures, equipment, and material shall be readily accessible for fire and police protection. The existing building was constructed to code and compliant with fire and handicap accessibility. The applicant has an adaptive re-use of an existing building. G.That the proposal shall.comply with the requirements of Chapter 236, Stormwater Management,because the existing building will not be changed. Any construction will be limited to the interior space. The existing building was constructed with a full drainage system/drywell, per town code, as shown in the building department records and issuance of the Certificate of Occupancy,#Z-16874,dated May 16, 1988"- In making such determination,consideration was also given to: A. The character of the existing and probable development of uses in the district and the peculiar suitability of such district for the location of any of such permitted uses. B. The conservation of property values and the encouragement of the most appropriate uses of land. C. The effect that the location of the proposed use and the location that entrances and exits may have upon the creation or undue increase of vehicular traffic congestion on public streets,highways or sidewalks to assure the public safety. D. The availability of adequate and proper public or private water supply and facilities for the treatment, removal or discharge of sewage,refuse or other effluent(whether liquid,solid,gaseous or otherwise) that may be caused or created by or as a result of the use. E. Whether the use or the materials incidental thereto or produced thereby may give off obnoxious gases, odors,smoke or soot. F. Whether the use will cause disturbing emissions of electrical discharges,dus; light,vibration or noise. G. Whether the operation in pursuance of the use will cause undue interference with the orderly enjoyment by the public of parking or of recreational facilities,if existing or if proposed by the Town or by other competent governmental agencies. Page 4,June 15,2023 #7795SE,The Endless Round,LLC/7785 Main Road Realty,LLC SCTM No. 1000-122-6-29.1 H. The necessity for bituminous-surfaced space for purposes of off-street parking of vehicles incidental to the use and whether such space is reasonably adequate and appropriate and can be furnished by the owner of the plot sought to be used within or adjacent to the plot wherein.the use shall be located. I. Whether a hazard to life,limb or property because of fire,flood,erosion or panic may be created by reason of or as a result of the,use or by the structures to be used therefor or by the inaccessibility of the property or structures thereon for the convenient entry and operation of fire and other emergency apparatus or by the undue concentration or assemblage of persons upon such plot. J. Whether the use or the structures to be used therefore will cause an overcrowding of land or undue concentration of population. K. Whether the plot area is sufficient,appropriate and adequate for the use and the reasonably anticipated operation and expansion thereof. L. Whether the use.to be operated is unreasonably near to a church,school,theater,recreational area or other place of public assembly. M. Whether the site of the proposed use is particularly suitable for such use. N. Whether adequate buffer yards and screening can and will be provided to protect adjacent properties and land uses from possible detrimental impacts of the proposed"use. O. Whether adequate provision can and will be made for the collection and disposal of stormwater runoff, sewage,refuse and other liquid,solid or gaseous waste which the proposed use will generate. P. Whether the natural characteristics of the site are such that the proposed use may be introduced there without undue disturbance or disruption of important natural features,systems or processes and without risk of pollution to groundwater and surface waters on and off the site. Q. The character of the existing and probable development of uses in the district and the peculiar suitability of such district for the location of any of such permitted uses. R. The conservation of property values and the encouragement of the most appropriate uses of land. S. The effect that the location of the proposed use and the location that entrances and exits may have upon the creation or undue increase of vehicular traffic congestion on public streets,highways or sidewalks to assure the public safety. T. The availability of adequate and proper public or private water supply and facilities for the treatment, removal or discharge of sewage,refuse or other effluent(whether liquid,solid,gaseous of otherwise) that may be caused or created by or as a result of the use. U. Whether the use or the materials incidental thereto or produced thereby may give off obnoxious gases, odors,smoke or soot. V. Whether the use will cause disturbing emissions of electrical discharges,dust,light,vibration or noise. W. Whether the operation in pursuance of the use will cause undue interference with the orderly enjoyment by the public of parking or of recreational facilities, if existing or if proposed by the Town or by other competent governmental agencies. X. The necessity for bituminous-surfaced space for purposes of off-street parking of vehicles incidental to the use and whether such space is reasonably adequate and appropriate and can be furnished by the owner of the plot sought to be used within or adjacent to the plot wherein the use shall be located. Y. Whether a hazard to life,limb or property because of fire,flood,erosion or panic may be created by reason of or as a result of the use or by the structures to be used therefor or by the inaccessibility of the property or structures thereon for the convenient entry and operation of fire and other emergency apparatus or by the undue concentration or assemblage of persons upon such plot. BOARD RESOLUTTON: In considering all of the above factors,motion was offered by Member Planamento, seconded by Member Dantea,and duly carried to GRANT,a Special Exception,as applied for,and shown on the Survey prepared by Nathan Taft Corwin,III, Land Surveyor and dated April 27,2022 and the floor plans and a parking and site plan labeled A%1,A-2,& SP-1,prepared by Zackery E.Nicholson,Registered Architect and last revised February 22,2023. Page 5,June 15,2023 #7795SE,The Endless Round,LLC/7795 Main Road Realty,LLC SCTM No. 1000-122-6-29.1 SUBJECT TO THE FOLLOWING CONDITIONS: 1. The Special Exception Permit granted herein may involve a change in occupancy or a change in use or a change within a classification of the occupancy.Therefore,as a'condition of approval,the applicant must contact the Building Department to make the determination whether or not a Building Permit is required and that changes will be NYS Code compliant. 2. This Special Exception Permit requires an operating permit and inspection by a Building Inspector from the Building Department that must be renewed annually.his the applicant's responsibility to contact the Building Department on an annual basis to schedule the required inspection.Failure to do so may require a public hearing before the Zoning Board of Appeals to review potential action to revoke the Special Exception Permit granted herein. 3. In accordance with the Zoning Board of Appeals,approval shall thereafter be deemed a lawful use as if the same were permitted by this chapter without need for a special exception permit;provided, however,that: a. All conditions imposed by the special exception approval shall continue to apply unless they,by their express terms,are of limited duration. b. All conditions imposed on special exception approval uses generally or specifically by this chapter shall continue to apply,regardless of whether any such conditions were expressly incorporated into the special exception approval. c. -The Zoning Board of.Ap,peals shall retain continuing jurisdiction over the same; d. The duration of a special exception use may be limited to a specified time period as set forth in the approval of the Zoning Board of Appeals; if the approval is silent as to the duration of the special exception use,then said use shall be in perpetuity; e. A special exception use which has been discontinued for a period of one year or more shal I be deemed abandoned That the above conditions be written into the Building Inspector's Certificate of Occupancy, when issued. NOTE: Violations of Conditions. A violation of any limitation or condition of a special exception approval or of any provision of this chapter applicable to a special exception use shall constitute a violation of this chapter. The Zoning Board of Appeals shall retain jurisdiction and shall have the right after a public hearing, to modem,suspend or revoke such approval or any term or condition thereof or to impose thereon one or more new conditions,pursuant to Article XXV, Section 280-141 of the Town Code. Vote of the Board: Ayes:Members Weisman(Chairperson),Acampora,Dames,Lehnert,and Planamento(5-0). a- ✓ram a/ /L.1z� LeMe Kanes Weisman,Chairperson Approved for filing (5 /2023 RECEIVED MAR 11 f Ap �w / o Zoning B� ppe'Eals ,V s ZEN DESIGN " xavmnmbxvmm mm1YLYEM 1f® TIIXF:ptIDf689 m mviewmx ours m usmur rum maa '^ SEpED A,, "^ p�D�z�K E NICj, PA D Ste` 04441s Pr 9TE 6F N£'�10 i;` ^ ®. ENDLESS ROUND GOLF xr4mum.Mxuv xom.m.m-ax REVIEWED BY ZBA PLAN DECISION# 5 DATED: (o r - _ tl � Al , RECEIVED �. r �1R 2 pi]Aj ••••• ZEN DESIGN /�.�S5� avwwmimvre ------------ Zoning Daard of Appeals w�aaax'iass'�'ez / °1 �wanz xuti a uaawxaezmm RED Ap, QED �E.NIgyO�ZOA i - S?ej D9461;yOP� F OF NEB ENDLESS ROUND GOLF . ' ermuuxxoao I xumumxr.•^n _ aam-ue.asaea aisle FINA4 MAP REVIO,WED BY ZBA DECISION# 1 S� DATED tea' BASEMENT PLAN LOFT PLAN --------- ® � A-2 e a o i I�S ' ZEN DESIGN c'\.T �`• �. : s �p';[ - F' �bti .xmr.eawuses } ^�G",F n� L 4= -.''$= i� CAST ' � \ :, C\ •:t 9 ;�a o�°C-yam zi:' ei \ .\¢_: [Sj. II:H $� j f`Sj • _ .. z �•, `e_'s �;E -- \ .,-�(�',`- " /�\-.?.: •`Y2J fY:i t;i;'1:[,j �..^m®.�:—^ I w -.j.. ;re' _. '^.( . .-;.�yf •�•f i\�'ir - r* ftil at;{`I a[i m xn°enn°uxu"°aa m�iaw .eJ'�a`` `: �T.r:'`• ..� .\: :: \$ \�.; +tfj�j•>S �{,5 Saj m utaurcrvnrt f_..•. .. ; f\-i5\`p Y: � ••\��w�%' u . S,SEpED qq�y 10Cr.�: - r• �\' _ MAR 8 2 7A23 \ ';c ``%y,\� •3: ,\ f ,��r �` Zoning Board of Appeals yr oan ass yoo-t \\ she•^�-`::. -, .\1`s/.-\�L-�:'^'i-%-� e°s neW . i s ec, i \ 5 \ ..✓ ENDLESS ROUND GOLF FINAL MAP REVIEWED BY ZBA -tee DECISION# 27`IS - `/ DATED: /ok la°a3 mtiv �A `- ovnwiaary zsx +v PARKING&SITE PLAN \ NOSE VAPNINGNECUIRFD WP FtIDIFbSRWND WIF.S5 \ PMXWOSMtOPo5FD50N FNO[FbSNWXDGOW.25 - --- - --- -- - ---- - - - ------ - - - - - -- - SP-1 S�fFOC Y BUILDING DEPARTMENT- Electrical Inspector COOy� TOWN OF SOUTHOLD Town Hall Annex -_54375 Main Road - PO Box 1179 T ' Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 r (a-southoldtownnv.gov - seand@southoidtownnv. ov ooerr APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ail information Re fired) _ Date: a 3 Company Name: a"A [ ' l L Re J- V1 c- Electrician's Name: C w t 40 License No.: S j 6 y 7 Elec. email: Elec. Phone No: - WO ❑I request an email copy of Certificate of Compliance Elec. Address.: PO 60 Id- 1 01 CLf 1 r; JV Y i l JOB SITE INFORMATION (All Information Required) `` G Name: e — v)dle h0uhaP 0 / T S+Ua l,Q Address: s- man KoaiZ, � (� 1 5- Cross Street: Phone No.: / - 'M - Bldg.Permit#: qq (Q S 9— email: Gv ,dl OI , Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): ,r;.dd�+��� � �eceP��c(es � y ( tJc�tff &vim SiMulato� $uy}_ O F t e� /1 ` Square Footage: (�100 Circle All That Apply: Is job ready for inspection?: YES ❑ NO Rough In VfFinal Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required), Service Size❑1 Ph F—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 n H Frame M Pole Work done on Service? n Y nN Additional Information: PAYMENT. DUE WITH APPLICATION rC W7 C,4Ll, Ve c# �U 55 y0 tA� CK PERMIT p Address Switches ` 1 I Outlets � �,{� \ P4 144 (14 GFI's rr �1�1 Surface Sconces HH's UC Lts Fans Fridge HW Exhaust Oven WAD Smokes DW Mini arbon Micro Generator -ombo Cooktop Transfer 1C AH Hood Service Amps Have Usec ,penal 1 omments RECEI®.r FOR INTERNAL USE UINLY R Q'D.2023 LAN USE DETERMINAT_-10[MLpannngBoard J SITE P • . lnit:iit Determination Cj 2 j Date Sent: f_(�_l `,� Date:3_1 t Project name: Project Address: ¢¢ ' No.:1D00=ML_ , Zoning DIS@ic L _ Suffolk County Tax Map' - l ' is �n 'cu%Id'r"� •�. - • •. Re (Note: Copy of Building Permit Application and supporting documenfafion'ag to proposed use or uses should be submitted.) initial D te. ination as towhether uses per fitted:- �4 S�e �IQI� Cui inittal•Determination as to whether site plan is required:_ signature of Building Inspector plann-dng Department(P-D—)R6ferraF: _ PA.Hate Received: i l .Date of,Counment^�� � wit v� fturcm�_��e, oc Comrrrents• _ o� sloe a� ;on. Af l $igna, re of F' tinning D Staff Reviewer l`inai Detettitination Decision: : - ' ' ' c:...,nhra nr Ruilrfino insnactnr The Endless Round LLC PO Box 16 ® I� II IUI I5 New Suffolk,NY 11956 lln!N 6 Bryan@Endlessroundgol£com January 17th, 2023 JAN 17 '2023 OWNGDEPT Michael Verity MOWN OFSOUTHOLD Chief Building Inspector Town of Southold PO Box 1179 Southold,NY 11971 Dear Mr. Verity The Endless Round LLC, comprised of a partnership between Bryan Zissel,Daniel Hagerman and John Michael Peters, is providing a letter of intent to receive formal town approval to open and operate an"indoor golf simulator"business located at 7785 Main Road in Mattituck. The specificity of our intent are as follows: • Enter into a lease at above location—approx. 6,000 sqft • Work with a licensed contractor to develop the front 4,000 sqft to accommodate 4 separate golf simulator"bays", as well as common areas serving as lobby, lounge and general congregation • The nature of construction will be non-weight bearing • The remaining 2,000 sqft intended construction for a later date • Business to utilize ADA compliant bathrooms already existing in building • Landlord to issue 25 parking spots for business use. This space will provide year-round activity for the visitors and residents of the North Fork and by the nature of the business operating model, crowding and congregation will be at a minimum. We look forward to our partnership with the Town of Southold on this endeavor and stand committed to ensuring a positive and well-rounded experience for our friends and neighbors. Respectfully Yours, The Endless Round LLC Bryan Zissel,Daniel Hagerman and John Michael Peters Can you please send us an email confirming what the HD response was to your inquiry for Endless Golf. If I understand their response, the HD approval for the Suffolk Times building was adequate for the building and proposed use of the entire building (the owner is keeping a small portion of the back of the building for his office). Endless Golf is occupying the front of the building and some of the building remains unoccupied for now. Patricia C. Moore, Es . LEASE BE SURE TO 00 RMA MY ASSISTANT betsv0mooreattvs.com,and kvleeArnooreattvs.com ...............I...........Mailing & Physical Address: Moore Law Offices 51020 Main Road William D. Moore, Esq. Southold NY 11971 631.765.4663 Fax Number: Patricia C. Moore, Esq. 631.765.4643 631.765.4330 www.mooreattys.com On Wed, Jul 12, 2023 at 1:29 PM Bryan Zissel <brvan(ZDendlessroundclolf.com> wrote: Pat, Can you please have John Condon confirm that an additional bathroom in the owner's office space used by 2-3 people a day will not max out the septic. Can you please advise that this is an urgent request? Thank you! Regards, Bryan Zissel Co-Founder (M) 917-993-1877 On Jul 12, 2023, at 1:27 PM, Bryan Zissel <brvan(c-endlessroundgolf.com> wrote: Yes-the owners have an open permit application with the town for the "private" office space of 2-3 people. This includes their bathroom. r Our load is max 20 people. Nowhere near the 300. And also nowhere near when occupied by Suffolk Times. Upstairs loft has a conference table and 2 desks and we use it as our "private" office space for the golf studio. 2 , Nunemaker, Amanda From: condon77173@optonline.net Sent: Wednesday,July 12,2023 5:10 PM To: Patricia C. Moore; Bryan Zissel; Nunemaker,Amanda Cc: Zackery Nicholson; Dan Hagerman Subject: Re: Re: 7785 Route 25 Laurel C%man- da,-J talkeSl:tOaC IS_aboutthis project a ew mo ths-ago �T-hePorigih-a Flb approval for the TI UXROimes -uil"ding'Was adequate,fpr-the-building-and-proposed� cjJse:of'the entire building including the office in th`e back of the building and Endless Golf occtJ in `the�frorlt-of=fhe buif8ing. Please let me know if you have any questions. Yours truly, John Condon, PE ------ Original Message ------ From: pcmoore@mooreattys.com To: bryan@endlessroundgolf.com; condon77173@optonline.net; condoneng@optonline.net Cc: zenicholson.arch@gmail.com; dan@endlessroundgolf.com Sent: Wednesday, July 12, 2023 12:42 PM Subject: Re: 7785 Route 25 Laurel Hi Condon Engineering- Needed ASAP- I am not sure if this was done by John (Jr) or dad. I know I spoke to John Jr. ' Amanda at the building department is reviewing the building permit application for Endless Golf and they asked the following: Amanda writes "I need to verify that the sanitary certification letter received from John Condon, is in fact reflecting both uses. I believe it is, but just need confirmation." t which will'yield a much larger occupancy resulting in the requirement of a sprinkler system, and the building will only be allowed to have one story as it is a type 5B (unless they can modify it to a type 5A). The concern is,even though it is unlikely the building will be packed out with people for this kind of use,there is always the potential of a special event to be held within this A-3 space. Do we accept the 8 person per bay count or use the state code requirement of 15 net. I would really appreciate your feedback and expertise on this matter. Thank you for your time. Amanda Nunemaker Building Permits Examiner Southold Town Hall Building Department 631-765-1802 3 s Nunemaker, Amanda From: dos.sm.Codes.techsupport <Codes@dos.ny.gov> Sent: Tuesday,July 25, 2023 11:21 AM To: Nunemaker,Amanda Cc: Nation, Courtney(DOS) Subject: RE:Occupant Load Follow Up Flag: Follow up Flag Status: Flagged Hello Amanda. Your question paraphrased: Can the design occupant load for a Group A-3 occupancy be less than the 15 net being specified in Table 1004.5 for assemblies without fixed seating? Our response: According to the Exception in Section 1004.5 of the BCNYS,the code official can approve a design occupant load that's smaller than the amount that's calculated using Table 1004.5 in the BCNYS.According to Section [NY1106.2.1 of the BCNYS,the code official can require whatever information they need to be assured that the reduced design occupant load satisfies the intent and at least maintains the level of safety of the Uniform Code. Code sections considered for our response included but were not limited to the following excerpt from the 2020 Building Code of NYS(BCNYS): --Section 1004.5 Areas without fixed seating. The number of occupants shall be computed at the rate of one occupant per unit of area as prescribed in Table 1004.5. For areas without fixed seating,the occupant load shall be not less than that number determined by dividing the floor area under consideration by the occupant load factor assigned to the function of the space as set forth in Table 1004.5. Where an intended function is not listed in Table 1004.5,the building official shall establish a function based on a listed function that most nearly resembles the intended function. �zceptiorisWKdre._pr,'oveii byAhe buildIng,ofHc!al;,thwactual.number,'ofoccupants.for,wh6nipeach occupieii;spa_ce' ooraor,bulidmg is deslgned;)although,less-,than those determihed b calculation,shall^bes er`mlttedltoaieaused in'th_ etermihationtofa heudesi n occu t(load' Let us know if you need more information. Stay safe, Bryant Arms Code Compliance Specialist II Technical Support Unit New York State Department of State Division of Building Standards and Codes 99 Washington Ave, Albany, NY, 12231-0001 P: (518)486-2298 1 F: 518-486-4487 Please Note:The opinions of the Technical Support Unit staff reflect those of the person who provides them and do not necessarily reflect the position of DBSC.The opinions are not intended to be legal advice.They are intended to answer specific questions about the administration or enforcement of the Uniform Code or Energy Code and do not constitute a complete or comprehensive compliance review.The local Code Enforcement Official determines compliance to the Uniform Code and Energy Code. The information contained in this communication is intended for the sole use of the persons or entities who are the addressees.Dissemination, distribution,or copying of the information it contains by others is not authorized. 1 From: Nation, Courtney(DOS) <Courtney.Nation@dos.ny.gov> �W Sent:Tuesday,July 25,2023 8:42 AM To: Nunemaker,Amanda<Amanda.Nunemaker@town.southold.ny.us> Cc:dos.sm.Codes.techsupport<Codes@dos.ny.gov> Subject: FW:Occupant Load Hi Amanda: By cc of this communication I am putting you in touch with our Division's Technical Services Unit.This unit is staffed with competent individuals who are qualified to respond to your inquiry and may be able to provide you with a quicker response than me. Regards, Courtney Nation, PE Civil Engineer 1, Division of Building Standards and Codes New York State Department of State Division of Building Standards and Codes 250 Veterans Memorial Highway, (Suite 2A15) Hauppauge, NY 11788 (631) 952-4915 1 courtnev.nation(a-Mos.ny.aov www.dos.nv.aov CONFIDENTIALITY STATEMENT.This email and any attachment is for the sole use of the intended recipient and may contain private,confidential and/or privileged information.If you are not the intended recipient,any dissemination,distribution or copying is strictly prohibited.If you have received this transmission in error,please notify the sender immediately by return email and delete the message and all copies and attachments from your system. From: Nunemaker,Amanda <Amanda.Nunemaker@town.southold.nv.us> Sent:Tuesday,July 25, 2023 8:33 AM To: Nation, Courtney(DOS) <Courtnev.Nation@dos.nv.rtov> Subject:Occupant Load You don't often get,erriail from amanda.nunemakerPtown Southold ny.us.Learrrwhy this is important" Epp Hi Courtney, I am reviewing a commercial plan for a conversion of an existing business building(B)to an indoor golf simulator recreational building(A-3). The rear corner portion of the building is going to remain a B occupancy used by the owner (golf recreational use is another tenant). These two uses will be fire separated. The question I have is regarding the calculation of the A-3 space in the golf bay areas. The architect states that each bay will hold 8 people and,the total occupant break down for the A-3 portion will be 61 people. I have attached the plan that was submitted with all of the breakdowns. I believe, by code,we have to calculate the total square footage of the bays and divide it by at least 15 net 2 Mejia, Evelin From: Mejia, Evelin Sent: Monday, February 5, 2024 8:48 AM To: 'Patricia C. Moore' Subject: 7785 Route 25, Mattituck Good morning, The commercial alteration permit (#49652) located at the above address, is ready for CO pending a Plumbers Solder Certificate. Please bring this in to us at your earliest convenience. Kind Regards, Evelin Mejia Office Assistant Town Of Southold Building Department Annex Building 54375 Main Road Southold, NY 11971 (631) 765-1802 1 BARGAIN AND SALE DEED WITH COVENANT AGAINST GRANTOR'S ACTS(INDIVIDUAL OR CORPORATION) STANDARD NYDTU FORM 8007 CAU1xAV:'IHLS AGR MlENf SIIOIIIDRP.PREPARED BY An ATn1RNkYAND aLVISWFa111Y A7TORNF ND YS FO0.5a11FA A NRCICIUSYx IIElOAB SI(amxi. THMIMMV71URI„made the 14nday of October, 2005 between S TROY GUSTAVSON and JOAN GUSTAVON,husband and wife, residing at (Doll)King Street,Orient,NY 11957 i petty of the first part,and I 7795 MAIN ROAD LLC having a principal place of business at 7785 Maio Rood,Mattituek,NY 11952 I party of the second part WITNESSETH,that the pony of the first pert.in consideration of Ten Dollars and other lawful consideration,lawful money of the United States,paid by the party of the Second pan,does hereby grant and release unto the party oftbe second part the heirs or suecestms and assigns of the pony of the second port forever, ALL Unit certain plot piece or parcel of land,with the buildings and improvements thereon erected, I situate,lying and being at Mattituck.Town of Southold.County of Suffolk and State of New York. SEE SCHEDULE`A'ATTACHED HERETO AND MADF,A PART HEREOF The grantors herein are the same persons as the grantees in Deed recorded in Liber 10138 Page 402. TOGETHER with all right title and interest,if any,of the party of the rust part in and to any streets and roads abutting the above described premises to the center lines thereof, TOGETHER with the appurtenances and all the estate and rights of the party of the first part in and to said premises, i TO HAVEAND TOHOLD the premises herein granted unto the parry of the second part,the heirs or successors and assigns of the patty of the=end pan forever. AND the party of the first pan,covenants that the party of the first pan has not done or suffered anything whereby the said premises have been encumbered in any way whatever,except w aforesaid. AND the patty of the fast pan,in compliance with Section U of the Lien Law,covenants that the party of the first part will receive die consideration for this conveyance and will hold the right to receive such consideration as a cost fund,to W applied first for the purpose of paying the cost of the improvement and will apply the a=firer to the payment of the cost of the improvement before using any pan of the total of the same for any other purpose. The word"patty"shall be construed as if it reed"ponies"whenever the sense of this indenture so requires IN WMNESS WHEREOF,the pony of the first pan has duly executed this deed the day and year first above written. , v TROY GUST VS N JOAN GFlTrAVS0N NYSM Rniemanrn Rol Emu Darman ilommr"lam, CaplNyucopson•h><Yxklm,en Schedule A t i ALL that certain pbt,piece or parcel of land,with the buildings and improvements thereon erected, silrete, lying and being in then Hattituek. in tho Tow of Southold, County of Suffolk and State of Now York more particularly bounded and described as follows: BEGINNING at a point on the torch¢rly line of Main Road, (S-R. 25) which paint is 2060 feet more or leas Want of tba intersection of the westerly aide of Factory Avenue with the northerly line of the Main Road (S.R. 25) and from said point of beginning. RbNNING THENCE South 51° 58' 50" West, 126.79 fast to land now or formerly of Chew; THENCE along said land North 37e 54' 20" west. 401.61 feet to land now or formerly of Liraa and O'Connell; THENCE along said land North 60e 24130" East, 127.37 feet; THENCE along other land of Sashes Associates, South 380 01' 10" East, 382.96 feet to the northerly side of the Main Road at the point or place of BEGINNING. I STATE OFNEWYORK ) COUNTY OF SUFFOLK ) r On the I dnday of OA ber,2005,before me,the undersiped,personally appeared TROY GUSTAVSON and JOAN GUSTAVSON,personally,known to me or proved to me on the basis of satisfactory i evidence to be the individuals whose m ncs am subscribed to the within instrument and acknowledged tome that they executed the same in their capacity,and that by their signature on the instrument,the individuals,or the i person upon beheirofwhich the individuals acted,executed the instilment. / NarY Public.W OW SEN b Now lhk NOTA UBLIC No 02MBEW4 Clinandailan"Gur ivishe DEED Section 122.00 Block 06M Lot 029.001 GUSTAVSON County or Town SUFFOLK I I TO I 7795 MAIN ROAD LLC I Return By Mail To: OLSEN&OLSEN LLP P.O.BOX 706 CUTCHOGUE,NY 11935 I Res ervc This Sluice ForUseOCRecordin Office I nr$RA ae,EmtiY rf+l Finaehmrm IlmDoe�l9Na) C0u Tbb C0WeDnebPm S- C _ 3 Numhef of pages RECORDED TORRENS 2005 Oct 27 09s 27t 13 RN Eduard P.Ror�aine serial IV CLERK OF SUFFOLK COCHIN Certificate g L 000012416 P 649 Prim of.a DT♦t 6-12665 Deed/Mortgage huwment Deed/Mortgage Tax Stamp Recording/Filing Stamps FEES Page/Filing Fee Mortgage Amt. Handling 1.Basic Tax TP-584 2.Additional Tax Notation tub Total Fit-52 17(County) Sub Total Spee/AssIL EA-3217 Or (Stale) Spee./Add RP.TS.A TOT.MM.TAX _ Comm ofFd s Qom_ Dual Town—Dual County_ Held for Apportionment Affidavit _ • Transfer Tax — Catiftcd Copy S(O Mansion Tax The property covered by this mortgage Is or Re© will be improved by a one or two family Sub TOW dwelling only. Other _ YFS_or NO_ GRAND TOTAL I(NO,see aQproPrint a tax clause cp page R ofthis instromenL f Real Property Test SmimAgency Verification 6 Community Preserve ion Fund --'"�" A""""• •• RIM— ._Lat •Consideration Amount S-" _ Q$Q42$i/1 1000 12200 0600 029001 •CPF Tax Due S Stamp P T ,01 Date R CWA A Improved Inhiab __ Vacant Land_ t Satisfaetions/DischargesfRoleasea List Property Owners Meiling Addnaa TD RECORD&RETURN TO: TD OLSEN A OLSEN 1LP TD P. 0. BOX 706 CUTCROGUE, BY 11935 B Title Company Information Co.Name COMONWEALTH Title N C04360 9 Suffolk Coup Recor ling &Endorsement Page This page fomu pent of the attedmd DR® mode by: TROY GUSTAVSON AND JOAN GUSTAVSON (SPECIFY TYPE OF UsIMMMENf) 1 The pnmdses herein is situated in SUFFOIXCOUNTY,NEW YORK TO In the Totvnvhip of SOUTHOLD 7785 MAIN ROAD LLC In the VILLAGE. or HAMLET of BOXES 5 THEW 9 MUST BE TYPED OR PRrN IED IN BLACK INK ONLY PRIOR TO RECORDING OR FILING. (OVER) 1111111111111111 hIIIIIIII IIIII IIII III III Ell llll IIIIII IIIII IIIII III IIII SUFFOLK COUNTY CLERK RECORDS OFFICE RECORDING PAGE ' Type of Instrument: DR]MB/DDD Recorded: 10/27/2009 ! Number of Pagea: 4 At: 09:27:13 AN Receipt Number : 05-0112869 TRANSFER TAX NUMBER: 05-12665 LIBRE: D00012416 PAGE: 849 District: Section: Block: Lot: 1000 122.00 06.00 029.001 EXAMINED AND CHARGED AS FOLLOWS Deed Amount: 60.00 Received the Following Fees For Above Instrument I xx t Exmmpt i Page/Filing $12.00 NO Handling 05.00 NO COR $5.00 NO NYS BRCHG $15.00 NO RA-CTY $5.00 NO HA-STATS $75.00 NO TP-584 $5.00 NO Cert.Copies $0.00 NO RPT $30.00 NO SCTN $0.00 NO Traaa£er tax $0.00 NO Comm.Pres $0.00 NO Fees Paid $152.00 TRANBFBR TAX NONBER.- 05-12665 THIS PAGE IS A DART OF THE INSTRDM3NNT THIS IS NOT A BILL Edward P.Romaine County Clerk, Suffolk County • PLEASE TYPE OR PRESS FIRMLY WHEN WRITING ON FORM INSTRUCTIONS:http:l/www.orps tata.ny.ue or PHONE 18181 478.7M FOR COUNTY USE ONLY �1 O Cl.WAR Co" 1 q / 3 , �/I REAL PROPERTY TRANSFER REPORT arATE OF NEW NEW Y C,Dm Owd RwcKd II O / 2 RATE BOARDOFIRALREEBIYBBNIDES �./ rsu wr `ate.'/ RP - 5217 CL IRO" l.� 7, l•�b1U.P.WIB, PROPERTY INFORMATION II t.P,p 1 7785n 1 Rain Road I � ...a a IpR- I so a I N..eeieuck' 1 119g 5 . R.b a 1I i u A IIr IYa. I[ • I IiTyl 1 LTw kl®e.[rr•km•Ta®aanbb al. Rv.R R.A.IDr blvadnYbbmod f.mll � I ..•[ 1 a161•r l I I I I lvanur.a..rn�A.a to•rlrw F1.9ia a bd1aY[E.nvmM dAr�rl IOML M d.la[a0 m.0 rD.l.IVIr• Aaa P. eamh amtb d.tl I I pdPamb on ❑ P.Id•P.nl aA RwlkV Lwd•Aa lurldd•nAWcN.Faun ❑ a.Oad AL McAdam ApwrdArRaWkdraT." ❑ ow. I Xi oni I .a P.m Appo.dbmkdt Mtk Uwftmld[d ❑ Rir I Guet:Evaon I Troy I w.. w�iwr.�ii"" nm.... 1 Guesavaon I Joan ).CTa[Alb ka bb.akim root apm.WldanW Murdlb w.aavatb tlwadads OarW bartNr.rdar.tak L OwnwdllPTkw rCaaminlum ❑ A Or F.mR/RYIO.n.al EAR WuM 1 Ca nmknry SeM. a Nw Commoftn on Yarn Um ❑ B 1 a 1FamY Rallp.aW Framm.eda J kdoaW tkA ROPan'I lomaOrbbrADbMnl dadn ❑ C�Raw$"Yarn wd aAp.dw. Wtlk 6aaa tlLAolalc.h.d adtla.v kbakv ❑ O Nw9&.wwWv=uLvd FINwffth Fj vow L raw v.lhp,appbbrADbmoa VaAd 9AlEINFORMATION IL CANbor W NM dlb=ow.•b.raPPh b.al�: .lt.Ra.ra.aad mb I / �yw I A mr3b Rdah..aF.R.b1w. B ab morn Rabd Cmmalr a Antit.r al.km C a.da.er,.nrm.sdl. il.Dbd Sam Iraea 110 / /05 1 o 9maWWwl.o�AAaV0L..6R.rtwm aba m1 nr• F. ma TM m W..ar am1Ad.ad Rb RRp.ft MMl F' Sab.IFrClwalatr.t Fw- am omdor mbd u Fw Sar P[Ir I - 0 m m - . 0 . 0 I O E4da .aamm. i'R. Taw Swmmawl.b Ork • ! • Il BbdtlWn.r bbdudd NSY A1Or O.rO9.YPro�n.bbl aal.R rl0 rar16•w.rM kandlV Dwa.W.nO.F• 1 On U.MW F.naa AmakV Sail Pam Op*,edwl TNa Ptmw.marbdbm Arrk,aka pl�p.n/orpmraUM uamgMd J Nw maftwmaakwomwi ) Rnrmwdto R.l.aw.dab delrrrlpuM. IA YIWu dr•da1 pamd pgraPRlabddrtb rr I 0 . O 1 AssLssmwr INFpWAT10N.Dab ahuubl msr the taut And Amm m Rdl ald Tm 6R ILYmdAr.ww mak— l Fu v nY0la rbnl.dm uh. tT.Tad Ars.d V.111.Id aAWr ,.1.I pa . r. 1 ! 1 ! u r..P.lq Cho A—L&L.1 IL5b lAl&MNam•I dZ4677"'t Ctrs,""' SL Tw AW M.u�al4/R.A ldwdardn IR ma.da.bOr,aad.k.a•mb addRwW Idm[trlttll 1000-122.O0-06.08-O29.001 I IrCEMICATKM I I I I I 1 mnO Ilol dl dlb 4a d lefolrtllmrlrnd r 1W faOr ote is ad[m[al On Oa bW dlF YwbdlR ow mm Ord 1 unimma o dw OR mwm d.q awulRY aa.arld.waddfatb[de.0 nbj1[am.bWeaa/lww dda uml bwaerd.ebWmtby wdlO{d Ofa hamlRRa Burg DUYEWS�AIT.00RNEY na• .u[ .n[Ar. w•a I���a2y% 63/ I 9r3y 76" a..r..r• m•n w. ,.,. a...,•.. .a sn� L NEW YORK STATE COPY ! N112-7v a \ ( C C; B, V 1 ZEN DESIGN `! r IISD EVERGREEN DRNE CUICHO LE NY 119� �-�✓-�`� RR ii Yr `\� N` !. w +. PHDNE 631513.6589 _i`� `�o�ay_ �t ♦ b. 7J0. S� f ':6 1 NO ISSUE DATE ��:. - - Ib v r�• ! t 7F�7 {'t f( a�� 02 REVIEW o1171i 03 USE CxaxGE PERNR 02.22.2] ER R J a � �\5t CyrT 044423 op•P G` w• �r FOF NEON . :�d.• � , - , 0,.. ENDLESS ROUND GOLF ^d 7785 rux RDM Mlilliutx.xY 11952 1 SD00-122-06-2S.1 _.` SDxIE NIS S DATE 02.2223 �— ,9' � ! DRAWN BY: LEN. \ 10 PARKING &SITE PLAN NOTE PARKING REQUIRED FOR ENDLESS ROUND GOLF:25 PARKING PROPOSED FOR ENDLESS ROUND GOLF:25 S P-1 SURVEY OF EAT I vAr of viva v noaysTo, ^r OR 51 "it 11% \`'SO('S sTr rte LIM I I rl rK TOWN OF SOU,NOLD SUFFOLK COUNTY, NEW YC�- SC Lf He. T000-111 Ob-:, u.0 .'.TO' uM )r, !oa .N. . p H,Y CLATUIED To. .eaiss.w,us "c uT . rn.uwK�o.'U."Y,uW 6N.v[ 10—... e boll. Ad X. � .�. . . . , .6 I Nathan Taft Corwin 0 Land Surveyor -zxsees= �•�., _, r Post•Irtntandfaxtmnemlttal emom Ye,ea"+ / 5 m 40 m� Of l `PNO ONN�y� C � ZZyP e 0 GSO tmg S N60°2 10°0s° °Oe dm `0 ley a e as° a 01 s n �0 % s DQ P9Y9'®DY ® 0 T3 1 ly � °°DD 6 D\ � T C) 20 D\® � 9 r�• f 0rp9L 113' CR '� G >T p pC wn yr• ! CC9 9A it A;O��� \,y�N,Q O \ 06 e \ {adPa A ' AREA = 49,587 SQ.FT. T. `PP�°P P _ \ \26�9 y N�q�o P 2 N y SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES 5' P Opp Approval of Constructed Woks H.D. Ref. No.(,/�7 The sexaee dopesel and rater supply flahtles at this location x + have bem sal smc.o spy .nsyected by Inca Depailmem and are iA,wm fiianee Ynlh Inese a mu airs. MAY___13TM a. Garta . 1E _ C lu 0, GENERAL ENbdascdmd bLRnofs ' SURVEY OF PROPERTY AT MA TTITUC K TOWN OF SOUTHOLD Pxw^d a med°^' "kl' the °ninim. SUFFOLK COUNTY N.Y. pe,mism a lea"Psm p m caabliAmd by y du LLA.LS.®d GPPmscd and ad°Pud 1060 - 122 - 06 - P/O 29 1,yA= by UA Now York 8mU Innd SCALE I" = 50' AININJudeac. AUG. 18 , 1987 OCT. 22 , 1987 NOV. 5, 1987(foundalion revised) L W 9` APRIL 12,1986 ( FlNAL ) f11DroI IVE ao s 11PF!SJV(�l lia6 ��y `IIl'Y111,1 Y9 Y 6 LIC. NO. 49668 MAY 18 / ECO one ENGINEERS,P.C. .0 OF (516) 765 P.O. BOX. 909 LOT NUMBERS REFERTO "MAP OF MINOR SUBDIVISION MAIN ROAD MADE FOR SUNBOW ASSOCIS� SOUTHOLD, N.Y. 11971 , 87 - 695 r ' New Weekly Dlamunta:WEFileYYDIBDi010 Abom Us S*PIp Ramrs Comma Us OrderSerus FAD FflCTO fl'Ys� r Search for anything Tablecloths Q 8aa ,w" ('Wlshnat WYCM — - -- - -- -- --- SHOP BY CATEGORY H.,Batictlrop 4unaina New ARNals 2 Pack Black Scuba Polyester Curtain Panel Inherently Flame Resistant Backdrops Wrinkle Free With Rod Pockets Chair covers -IOftxloft _. _ .. _ situ:cuRraNPokYalx Chair Sashes $39.99 $6399 S $24.00 0y9. Rectangle Tablecloths ***{f*(S18) Round TeblecloW SquaTable Tmbledoths Pack CaseofBPackain ( Pack of 2 Curtains Curtains) Table wedays (�;_ �) � $20.00 each CJ $1800 per curtain Table Skirls R.t Save tO% Table Runners ' Linn Napkins L7—L�—] +F I Add to Cart Disposable Dinnerware $49.00ta get Free Shipping Chargers&Umerpleces Ships from USA:Deliver by not O4-Old 09 84.8%tlegvedes wlNin 4 days. Artificial Flowers 8 Greens t/tz Backdrop stand _- Color Bieck 1 More in Black Celling ps Ewan Pro '` ''F ■ ■ Parry Balloons&supplies ® 7`ef � MEMO ■ ■ ■ Weddng Favors ?? Fab ic8o nga D 1�V L7 V L7D ---------- Fabric DkorTrims . ® ■ ■ ■ Theme Dacer (: ) Homo OBmr Big cleaence Sale OCT 2 2023 Ol Q,Ck Collection Style:Polyester BUHMING DEPT. Orgama Polyeste TOWIN Cr SOUTIs0111D +OVERSTOOOWO 0+ '€ ., ... .�-.�._. Qurally?pce Backdmp QutaW matatet Sudu Potyeen, Ctlor.III.& ToLI Dkrvulws l OfM lHt ' ' `Fill ParaiAaddR tINt 'FedrPsslWldae Sfr Thlelmmctmm Rod Porbffi 4' Edg¢0m,Cm Unflashed Edge Flro Raadam Yes WMBa Sma Yes Sete lafarberkdmponty,smrW b sold separately �bdrvayriam RNedla(IF.B):Thisrype of apd:free flame+eslaea ' Ih ainflrm 4rto=m fweewholehestlerelorilame reaWm wasiA ' .nsneinilamereslaembNawhole rdeof NefabdG orupro2a washes. �PNAct(armodhWer,PoxydtlreUrtl ' sae la+otaaakNw�n.elmE heaasapaaey , fyq) Information I"7J Fire Retardant Curtains +J With Nestdm Aner bantab poce,plmhduublfM.our PoN Prania UrapeamakeepefMdmice fa baddh ofcl The kga 1%affvwabe,and Paruee.Paobooths,perfect ma,dcaas,ar gmatilm youemWmadda[slothimdoss Thesaupaf eHordeble,end Bumbledm lmakeaMoholceb maim aAreaInvesunent Wlihihadimimaiva feaum thememiadallon,aMul mfetyareaaence&ams lush PoyPrmrkT DmPes can beusedameend tlme TOP � 1 � egaNwgh Nammevbnnry,assured eatery entlflawless ri�artn O6tlflRe+f G¢rona lam 4 Search RM. Curtains Quality Delivery Men Backdrop Company Purchase Look Item Shipping WleWt..L Verified Buyer W182PI3 M U�srmez A 1 recommend this product ***** tLye Great!I kwe the depth ofcolorand thickness of the cloth.Fro using as a backdrop.I'll likely orderanadherpalrtor a more lull look v snare waotho,rw 40 10 M.S. Venfied Buyer ONVIZO33 AS® un�edvates ***** perfect I used this Item at a rend babyshowerlar a dlem.Thesewere betterthan I expected.perfect NFJ eS share Was"hOPW A 0 7 0 Breezy Venfied Buyer 07,21a 3 Be unmisa ***** perfettl Perfect badhCrop Forafforul Chemed babyshawer.thew nlcleswerent had out ofdhe paclmge and the anesthatmnetheramre nothardm steam.nice and opaque. M��j et Shure Wastoomprun r 0•0 Christ.L Verifled Buyer oMsrz0]3 UMed mcas **#** Fabulous Curtalm; They were perfect to bkadt out the wall and they steamed out so well „ h. c,Shure Wa,"helpru0 •t VI "awlR Verified Buyer c2WMt3 AF� Umedsteta ***** CortlnaspollEsterencolormomdo Muybuerwolidad TOP i C shore WasMts Wow r 1 •1 ANMale W. Vedf di Buyer I9 on uo,ed5so. trxs}trtr Red Curtains W e lave them they were great fo r our even[ r C Sharre Wazmh hel" •0!1 SareC Verified Buyer tt29rzOn SC® uwtedsam BAAAA Meencada Me enrardamn superbuere calidad la mejor Belo mejary los pnvdos super buenos. C 9fare wadtlstrelpfuR J t •0 So. Vented Buyer 11292W2 SfO uweasaus ,rAA4A LarecoMendosOperbuenaralidad Me eruanta super Buena calMatl el tamaf o super buerro na barnparenta me encama b remmiendo mudlo C Share Wa mlohelPW. 40 70 CINOYM Verified Buyer t0/092022 CB® U.1o,d W. A&*** Burgney fire retardant panels Wrethem,meyhung nireyand easyto imn. D�1111 a 2 C Slwre Was Nbadpr R J 1 •0 LeWITC Verified Buyer 10M20n LC® uMM sores tr A1YAA I-owit ItanNed fast,OY beautiful and easyto putup.I will deflniteyget more tvll- `` C Share w tN'he " J T1 < 1 2 3 a S 6 7 9 9 le > / Subscribe for TableclothsFactor/s promos and news I Enteryouremail Subsrsibe a f p 8 y asp Infennaaon Customer Serriw Poodes Pmduo Pboul Us SI,M Shipplig lnfamietlon Shop Nl(aategodes _ s 0. Fmo A.Cart Pmery Pdx.7 .19G,323' AWARDS'} Wholesale Ordv SMWe Termed CoMNona .`.IGCPrY.`+ IN mp 02 1! Sire Chang ComaRUs FlOEWe Remns '] 3 PuNuse eNera guest Ao Ibllhy Tablecloths FRCTORYA I iPaY a� MSA n Copyrl9M®20 MbledotllsM q.mm TOP - d''O' •L 9'-7A9'-7A L lay-%'°1' 9'.9r j4l.yja. 5'Y I 5=7° dypn �t.A9 �, d'-OOOT d'. A Ij.,-- U�//° -J�- d'-4%d" U'-v" d'.7" d'-ded° S'%E0• JIL-7 ° d'4' I ml•, ' _ .' *�—�o rd NG u" ' Ro u �d ✓ ro=Q'z" 5'-I �a° d'c� U G Zk° POF u ¢'n"U p.c• �d'.d ILA v� Iy� •1 -� J IGIIIE �� '' ..0 23'�2A__. ..-_ _ I'2" 12° l2° ID-o" _0 @ / ft" �h,JLd [uh1(faJvlRI� w:/� - - F I•�iP°J ri 11 ' ry-O7'kl(aH UP I X 9' r T7a Yim-- ,�M� _ � ---�: I rAwl,W - - m -- r 111it,� Its,may 1� �Pv9gcu.E UIV IN IZIN 41 ,(pc1Art, 14' ee�� /f ,Zpl.yA yBA I q' I I ' - 'A ry+rvv --7t I uL 1p F.•,mca s »a up 1. s7eA QFWI¢l� II 8- - 9 d 2 __ __ ___ 51 U-_- r Id•.(( �/pl ° cVY _ ) _ cr. � k x x�As`.s✓er a,za �`eb k`N� _ _ oPP A..P: on AE A-I a •.+ w-qY 9. to ^ II 11 _ � / -exE1 � � _ F cG - '✓ATmJ- _ ca i L� wr'wr A Mom' \ lr' �a � ft — O �_ •a chi ui� 6 _ ICA 6i AeE ITLatW :�TM1aJ b h —�� ea,:a. �i4 %axf i S:ili y- `„ mw ?L{q rar Tlj f "r�. ` •pia y�w ,lot \! ;lo oEast =i7af' a �t. 9 9� e o r� 'na =-- t -�A e tscr� �' +�•an N I ilk Y ]IF- tn CAME gNJ`&-w 41, s o �� ' O a pr' IA 4A � 118 ___f>-D___ ✓:-A' ' � II�C IFp' Uld' ,un !u' _ - _ CV RG p.p ' 4CVG INH _Y &'1411d0 44 � (W / NiWZtat elb/h,014 w ��l A1SgCyrr '-'.+oHro Eo •-AQI..Y J�'Excr G�nJt�G ° NOTE: Q^RRETT A. STRAND 'rNaa aN - / TMt[ N2 P[mlaEo saw architect YCMf II�YWr aNLY. -..•.y.:p-n [ytpyl [YM[ F➢EEPEEAFE / Main goad P.O.Boz 1413 Southold N.Y.11971ezAAg OW['llla faY °•'•pJEar.l1981= ,`.a,:wwar.ahwl..d+%�,• /I of nM yy 7a9Q[(O'STtlCTaLLk 1[RapWT1Y 616-766.5665 ,q L a � r - L fl 1 FC, _ _ II. : Ii�l u O ,hFw% ji 11 1 1 [1' 'v I, U I vi, X, V.? 1,-4 L g) ®r (D 44 L II a 5Ld v2 L -vy �C 3 Vile JI CA M u4\ QY — I --1 =1- _ L 17— OF Cp F" w'. ®R Film NOTF: GARRETT A. STRANG ...... lid JU1,CHITECT3 SU&M architect THIS D11,011's is PINIVIDED Sit maITECTull WCUT UNIT. Main Road P.O.Box 1412 Southold N.Y.11971 Kvnlan516.765.5455 2611,014110, It A.M61 a 8 IL'-nsa• � --- tr 2,5',`7,0�, '2'sy m" 12,-2n � _.-p—y.v"- f'�' Ij L-21 2'.9 a-a• 20�3�1 2'-9° 5Idl ell ML 11.-4n k. 17'.L'I '•d" ?q. l', Id'>° j':d'. —__Ib'_o° __ _19'.d^ I:de d,l MB, O •-0 _ I + -6/IfWM.W d l:Y * T—� r� ��.� �tv rH O _ ��� 7` � � � O Uf. r� l Z) <' ��4'k�Ml (>x,"-t•^W6 , P�i�60"X91M6. C I Y 1 �. �II� �' ' !L�'4 I�YIh drly' � N� I I�IN>$ f MTUf 3:5 latlnoul N 3°t - I - _ p�[J1L mA.NCb � 0' SPE�fp"IPj�-. Di+'IGIJ/A.Wtl6, p`� '�� y\ • %lil --�{, - --.��'-1 r—i * -ram G L° --Y .IIL i3L2"� a�" r r=-1 _ t I r !-�1 ._..1 �-�� 1� 12°I ° j . - .._ __. _ _. _. ° __._ . _ Xell __ __ G>° _ .S, _I 1 f0'O" Id 0° ✓ f IQ' � ' I Aj - 4 kl /-� I✓ i NaI{Y) y¢` F//vc��l`1 b' f(� I ' a� A = IT o ''�� E Ch1EJI(v✓aN1E nI00 �t , bK'g�/ - d�.b✓E✓ccu(/NE G�Y c. _ V r 4'. ps Nci o r�Y �P 6 L_-1 1-_i - L I_ !._. 44 lv ® G 12'-0° _ It'E' 1 � L�E" % Id_->' �' Id'�d' _�-._.Ip.._ __✓'O° _- Iva A __8" � 112' -�- G. 1T- 5n 111 I O O zm 1 g Y i �0+5 hdlCn6 •r, a dl of aEix. IVM,I,i"MJVEJLPGm_ly ----- W .� IViti;1 T1, Y >=a �OJ�Ir���lOr�� � I"J,�✓�I��.NL (°:�'�� aa= WILda1To4A{OAl2f{CikJYL(4YO. fv �r-u.°'^ha+ •u.:L. 152°ImJf:J�4:r':= id'aw/e'2T�E`ffi!IY�o-,c�LPWaJ b ME'Pv§'IW Lb °(:/daEir�f1E�p6�.TM15 12]2 / RIE '�c�1ylq&ca lMfm'f Fa11°n� +'�%I'w�kKlo \` \ C C�'+���4G�JWI., aJ qu P,!!PI S',.AFa':4:aa]C x MKtiIN p!qo�!{N�prvb L"E07,114. 10bgsea % 2�e{e-lE�w rrtl W4;FM++aa,°K aN�l.�H,rJla No F°: GARRETT A. STRANG �FFaK `Mrs W �✓�o 'QF�nFJ � architect THE 4E4MVING 1 SE4L ON `�'f T lyrwJ�'Y�'Nc Palo THIS TECTUa6 IS PEDYIDK PoE AEQItTEC WI EBE DNII. Main Road P.O.Box 14129out hold N.Y.11971 e,b!a. EEfEEEECE STO OE AL TO SWEa4IE 516-]66.6466 FNEIMEEit STEIIClDx4L Da4EIF6 FOR 'E4 aEW1E5D STAXTUEAL':NFQ WT10X a,- Yo kv.�.x,ionm;gW Sr✓'= IofO i a 1 - ! GARRE�TTt A. iTRANO �+w+r�.,�•r-��µ •.�wr,d .n.n _ - .t _ cam.. - ZEN DESIGN vwerw6P¢xoPrce GIIOIOEKel1 11936 %IOx[:6116116'v69 xn issue un pi PEVIFN56t 0101]] ENDLESS ROUND GOLF OiR 0116]f ® OP1WN w: xex PLAN A-1 ZEN DESIGN f VFRO m.. LNMOGYLM'11915 MOXL6t16118Y9 NM W. wn 1 4 f ENDLESS ROUND GOLF ENDLESS ROUND GOLF suer: xn i' lo'a• f8'd' wn: osws oNNvmer: sus SECTION A-2 ZEN DESIGN marvmmoano 12SO EVERGREEN DRIVE CUTCNOGVE,NY M35 "ONE:631511.6589 b b j Wpw us•v � ra.v ura - urx � I �mrr.vymnaammo�m.vsowem,., e•xM1�um o�wa,ema me�iaw M j ma pa��mgr6 x�YGmeW I N0. DATE I Illy--IuJ I b b 02 REVIEEW WSET OL1723 c� m 03 USE DNANGE PERMIT ""m ----------------------- ------------ I / ♦ / vmat ZORED ARC O N Z w.a ..mx s vo 1 •1 04444*5 ?r m..0 9TF O OF NF"4 y _____________ I♦ __ /I is ENDLESS ROUND GOLF I I NX 7765 NMNROAD I , ; MATIITUCI(.NY 11962 I I � ]000-322.06-291 I I I � �� SCAIE NT5 `S) ♦V I v an M DATE 022223 va ms va ma I DRAWN BY: LE.N ♦ice PLAN A-1 ZEN DESIGN =50 EVERGREEN DRWE CU MWUE.NY M35 PHONE 63L5D 6589 n.�m..4 eNiw�Ar.e�v sw..m s w ------------ uo.ro:.i v usa�mo.eso�o..vor..m .eo i N0. ISSUE DATE I 01 REVIEW SET OL123 02 REVIEWSEY2 OLS7M ]25 03 USE CHANGE PERMR 0212.3 I vY! 1 1 1 1 1 ySERED AqC E.N(CH y/rF C!F Ca 1 N y 1 1 1 _ •I 1 i I i 0444S" ?� 9rF 10 OF ENDLESS ROUND GOLF I 7785 MAIN ROAD MATIRUCN.NY1i90] 1000-1u-O6-]9.1 I SCALE NIS I GATE 02??13 I 1 DRAWN BY: ZEN i i BASEMENT PLAN LOFT PLAN . I 1 a.:.� +.' ,f, . x, 7. a. j ! r � s' a`a*.• '' � C tr°xx' +..'1 '� '3 w �°,.1�A�`,' +� 3 ,'h'. h',;�".�*�+ ROUNL.) xj a µ'.' .F +,J ,x $ •M, -0' %'^ ' `t.ry-r - 1.ri° 4 R t X "7 i C ` v '� D om� 0 NL F �, °,, �° �, . ,�- SEP ' 6 2023 v 4 ; t �w-. '.f"?a* .'gyp '+ 4✓ 'q` -,{ w x 14-S D ' 4 'q •a- �,',MtM �' ,p- C._ fig : x�..a k, ,kr 3u61�ing epa► m; EN DESIGN 7785 MAIN ROAD •k _ _ . , /__ � yr k TQ��,ofSou Y .l , ` ia' x`ax °s.x l s f•+. 14 { s/a A • ���� ' �, . 9 _" ��, �Y/ ., 1` � 1250 EVERGREEN DRIVE - CUTCHOGUE NY 1193 MA�'ITUCK NY 11952 '° , ^ ;` r.: �', . ,;xr' ,e. ' {y�}/ PHONE: 631.513.6589 3 ' 'o r ,-•i -. �y "''•{�, �,, Y� - '� t„. a 'x° .. ••x r "� • 3�. .. -3 S S.C.T.M. # 1000 122 06 29.1j r tw% These plans are copyrighted and are subject to copyright y$';: • protection as an"architectural work"under Sec.102 of the Copyright Act,17 U.S.O.as amended December 1990 and known as Architectural Works Copyright Protection Act of 1990.The A protection includes but is not limited to the overall form as well xP -tt ,, �s 'a �`x' r M, ,� {'t ; �r as the arrangement and composition of spaces and elements of design.Under such protection,unauthorized use of these plans, work or home represented,can legally result In the cessation of construction or buildings being seized and/or monetary to compensation ,'�° t,:r* �'t4jP•�?±t_�t3t: �" � ZEN DESIGN LLC. 75 ISSUE DATE 01 REVIEW SE 01.15.23 T 02 REVIEW SET 2 01.17.23 02.22.23 PROJECT MAP 04 CHANGEUBUILDING PERMITIT 07.21.23 05 REVISIONS 08.07.23 06 REVISIONS 08.25.23 07 REVISIONS 08.30.23 APP 0 ED AS N 08 REVISIONS 09.01.23 GATE. B.P. � 09 REVISIONS 09.05.23 FEE 6� BY: NOTIFY BUILDING DEPARTMENT AT (� 631.765.1802 8AM TO 4PM FOR THE S�j( [J M I FOLLOWING INSPECTIONS: 1. FOUNDATION•TWO REQt�I'TED FOR POU"�FD COIJCRFTE a(,a r01 2. ROUGH-FPAMING&PLUN03ING N OWNER OFFICE 4. FINALS-CONSTRUCTION MUST I � �S 4-,� �re- CRIMP TION m Q ENDLESS ROUND GOLF BUILDING BE COMPLETE FOR C.O. LEAD FLASHING NEATLY ALL CONSTRUCTION SHALL MEET THE PROVIDE LEAD FLASHING W 12' OWN INTO TOP OF VENT PIPE EXIST VENT THRU ROOF NEW VENT THRU ROOF REQUIREMENTS OF THE CODES OF NEW pKx FLANGE, MIN. 2 1/2'PER SO FT BOUT 1" YORK STATE. NOT RESPONSIBLE FOR ROOF SET LEAD FLANGE IN BED OF DESIG,NORCONSTRUGTONERRORS ya MASTIC Z 2 PILES OF ROOFING FEL TS & MASTIC OVER LEAD FLANGE EX. HC. TOILET EX. JANITOR CLOSET EX TOILET EX. TOILET NEW HC. TOILET NEW. TOILET PROVIDE MASTIC 0 EDGES OF ROOF FELTS N ROOF INSULA 77ON COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODE ROOF DECK AS REQU077) AND CONDITIONS OF EX. SINK EX. SINK EX. SINK EX. SINK EX. SINK NEW. SINK SOUTHCLp TOt'Vht Z5A PROVIDE SLEEVE A 7-� � 7 7-�- NECESSARY oLTJ ._ o o -- o � o _ ANCHOR PIPE TO ROOF DECK OR - - - JOIST W/ U-BOL T AROUND PIPE BOARD t-t/2 EX W�. t-t/2" t-t/z" EX t-t/z' t-t/z"', EX. t-t/2"j Ex. trc N & ANGLE IRON WELDED OR SC !- OwV USTEES \�,�ERCD gRC'yi 1ST FLR — SECURED TO DECK OR JOIST. c �w4 V R� E. N/C/ T� O� n 4• 4• 4' ii• 4" Q- N� Z PROVIDE PIPE INCREASER P UBLESS PIPE CONNECTORS ON Cl OCCUPANCY OR ► I i WHERE REO D TO MAKE MIN. , TO APPROVED _ _ 4" VENT THRU ROOF `��►�, SANITARY WASTE EXISTING E.W.C.I. MAIN WASTE PIPE --- USE IS UNLAWFUL SYSTEM REFER TO PLANS FOR VTR PIPE SIZES & LOCATIONS LOCATE `Sj p 4 4 a - - -- -- VTR 10 FEET HORIZONTAL OR 3 FEET VERTICAL ABOVE ANY WITHOUT CERTIFICATE �! 1 exterior li �rF �O BLDS, OPENINS OR FRESH AIR INTAKE, OR 1 FOOT FROM ANY ghtin of NEB SA APPROVED - OF OCCUPANCY P - SANITARY WASTE EXISTING E.W.C.I. MAIN WASTE PIPE VERTICAL SURFACE. REFER TO SPEC/FiCAT/ONS �n ta'lled replaced or SYS IEM re fired shall conform VENT THRU ROOF DETAIL to Chapter 172 f the Town Code RISER DIAGRAM NOT TO SCALE ,�_-_��'LU' 1BIN,G� NOT TO SCALE ACL PLUMS1N6 V1 G'1E &WATER LINES NEED a OR9 COVERING ENDLESS ROUND GOLF PLUMBER CERTIFICATION 7785 MAIN ROAD 17 MIN ON LEAD CONTENT BEFORE MATTITUCK, NY 11952 �-AL TERNA TE CERTIFICATE OF OCCUPANT 1 12 MAX 40 42 MIN SOLDER USED/N WATER S.C.T.M. # 1000 � 122 — 06 — 29.1 CLEAR SUPPLY SYSTEM CANNOT 36 MAX � FLOOR ll EXCEED 2110 OF 1% LEAD° SCALE: 1/4" = 1'-0" TOILET SPACE - PAPER 34 MAX 29 MIN 38 MAX DATE: 09.05.23 - -- � 27 MIN ELECTRlC�.L TN INSPECTION REQUIRED "LAYER SHEETR0CK 6 MAX TOE CLEARANCE DRAWN BY: Z.E.N. 12K4 STUDS FIRE INSPECTION 19 MA KNEE CLEARANCE 8 MIN 48MlLI 17 MIN DEPTH " " " " � REQUIRED BEFORE (J) LAYERS 518" TYP X GYPSUM OPENING SIDE WALL OF ' STANDARD STALL A T LA VA TORIES UL- U408 2 HOUR RATED WALL SEPARATION MAP $C FIRE SEPARATION DETAIL- - 'h,'shes TYPICAL DETAILS _ I AP ( ANSI DETAI � S �Q� ( ► n-�.r10�HAND C _ NOT TO SCALE 1„ 1, 0 Jf 5 h a l I Ccm p'y L"i 0 �Id � ----------------------- I' '---------------------- : « j II II � II II II II I I REP.IOVE EXISTING II i ON �n PATIO GUARD RAILS II II II II II II II II II II II II II II II II II BUILDING ZEN DESIGN OWNEROFFICE I I I I I I SPACE 1250 EVERGREEN DRIVE CONFERENCE ; ; I I i i CUTCHOGUE, NY 11935 ROOM PHONE: 631.513.6589 I II II II II II II ___ I I I These plans are copyrighted and are subject to copyright protection as an"architectural work"under Sec.102 of the I � II I I Copyright Act,17 U.S.O.as amended December 1990 and known COVERED as Architectural Works Copyright Protection Act of 1990.The PORCH protection includes but Is not limited to the overall form as well I I ,� I I ,� as the arrangement and composition of spaces and elements of UTILITY ��,' i I i i ,'�� design.Under such protection,unauthorized use of these plans, work or home represented,can legally result in the cessation of I CLOSET �, I I �, construction or buildings being seized and/or monetary II II compensation to ZEN DESIGN LLC. 11771 II II -------- -- ------------ J ' ------- /,\� NIO. ISSUE DATE II � II ' 01 REVIEW SET 01.15.23 I � j II II II II 02 REVIEW SET 2 01.17.23 UP 03 USE CHANGE PERMIT 02.22.23 OFFICE 04 BUILDING PERMIT 07.21.23 ' I I 05 REVISIONS 08.07.23 I " I O OMEN S IIIiIII IIIIIIi EF�ms'i 06 REVISIONS 08.25.23 07 REVISIONS 08.30.23 08 REVISIONS 09.01.23 09 REVISIONS 09.05.23 SERVER IL RENOVATED JHCMENS ROOM STORAGE L---------- � II II II II ----------------------- BATH 2 FOR NEW HC FF====i BATH 00WBATH 1 O � II 1LJ I I X I I REMOVE EXISTING PATIO GUARD RAILS JANITORS ENDLESS CLOSET ROUND GOLF � II II STORAGE -_--_---_----------- II it SPACE II Fr= UNISEX HC i 14 III BATHROOM TO BE II ---J ENLARGED ii II I I I I O i i OFFICE I I it I I I I I I I I II COVERED II PORCH �� II q R �. C ------------------- O I I N !� 2 IIII II 04442 OQ' OFFICE i i TF Q -4 IIII I I II I I I I I I I I I I I I I I I I ----- ----------------------- ENDLESS ROUND GOLF 7785 MAIN ROAD MATTITUCK, NY 11952 S.C.T.M. # 1000 122 - 06 - 29.1 SCALE: 1/4" = 1'-0" DATE: 09.05.23 STORAGE LOFT ENDLESS c(b DRAWN BY: Z.E.N. ROUND GOLF o Lf_-GEt�'J STORAGE `n EXISTING STUD t','ALL -------------- DE'.'D t"'A.LL/DOOR�tY"s'DOiV -------------- N11- D 0 0 R EXIST. D007 NMI' STUD WALLS 11 EXISTING DN DEMO PLAN Air 111% g 0 5 25 -- — --- - ----- -� ---- —-- - -- -�-1---- --- -- 5-Ox6-8 3-Ox6-8 00 DN q 4 - ! U) BAY 1 0 BAY 2 60 BAY 2 Sa SD LOUNGE ZEN DESIGN EXISTING BUILDING OWNER Co 3-Ox6-8 sD OFFICE SPACE co CO 1250 EVERGREEN DRIVE F.E.® CUTCHOGUE, NY 11935 / \ / \ PHONE: 631.513.6589 / \ H / \ AS BUILT BATHROOM TO BE \ RENOVATED TO BE ANSI 1-- --- -- + AS BUILT BUILDING OWNER OFFICE / \ CO "PLIANT I 5'-d" / \ BAY 1 / \ / \ ! LOUNGE These plans are copyrighted and are subject to copyright 3-0 6,8 TVE� protection as an"architectural work"under Sec.102 of the Copyright Act,17 U.S.O.as amended December 1990 and known l 1 r.F.E. COVERED as Architectural Works Copyright Protection Act of 1990.The o VESTIBULE PORCH protection Includes but is not limited to the overall form as well � ` / \ / \ to as the arrangement and composition of spaces and elements of 9'-6 1/2" Cn �y 4-2 UTILITY / \j / \ design.Under such protection,unauthorized use of these plans, work or home represented,can legally result In the cessation of o CLOSET / \ / \ construction or buildings being seized and/or monetary � NEW UNI EX ! 5'-1' / / compensation to ZEN DESIGN LLC. lC.BKTH W co x _ M U F[. 6-Ox" &0 7'_10°' r� �^ �n NO. ISSUE DATE AS BUILT �a G,AXI .,U,,.TRAVEL DISTAN" E TO EGRESS DOOR=100' B ILDINGa �; rt WNER _ 00 —0 ENDLESS EGGRESS DISTAN�E=65' STAIRS 01 REVIEW SET 01.15.23 OFFICE _'� x ROUND GOLF 4'-5" UP TO LOFT - 1 02 REVIEW SET 2 01.17.23 zt4 SPACE _1 3-0).6-8 3-0x6-8 3-Ox6-8 (NO PUBLIC ACCESS)UNISEX 04 BUILDING PERMIT 07.21.23 x6-8 �® BATH 1 co FOYER 05 REVISIONS 08.07.23 � �o As BUIL V 11-11' ®N SD 07 REVISIONS 08.30.23 STORAG Co 08 REVISIONS o = O 09.01.23 s® ' CLOSET -`- o C0 09 REVISIONS 09.05.23 Co S'-6" —+ WOMENS MENS Z LOCKER LOCKER 0 `�. ROOM 1 ROOM 2 00, \ o j NEW 1'-11"*x PUTTING GREEN 00 c� UNISEX HC - cov SD SD O o F-( ATFii '' UNISEX co Co O O 2 HOUR FIRE SEPARATION BETWEEN BATH 2 cc OCCUPANTS.SEE PAGE A-001 FOR € '� x UL RATED FIRE ASSEM,PLY DETAILS 04 00 JANITORS cx O \ CLOSET 4 FRIDGE ' ENDLESS N N \ F.E. ROUND GOLF STORAGE 3'6" NEW EGRESS PATH -- -- - 6-Ox WITH CURB CUT TO SPACE I PARKUNG LOT N GVE. UNISEX HC co \ / \ / BATHROOM 6 ECG^ SES DISTANCE=60' io 3 3-0 6-8 -Li \ / \ / COVERED \ / PORCH Z 6� BAY 3 LOUNGE \ / M \ / \ / NV tr0 .a V V BAY 4 sD LOUNGE D SD �` Co S ENDLESS BAY 4 BAY 3 04 4 42�- ROUND GOLF ODi �TF OF NON OFFICE SPACE ±27'-9" ±15'-2" -- - -. ..- - -- ------- - ---------------- �-.------------ - -- - � ENDLESS ROUND GOLF 7785 MAIN ROAD IF MATTITUCK, NY 11952 so �!TER�",TtOr"�'i�'OTES LEGEP.'D co S.C.T.M. # 1000 122 — 06 — 29.1 1.OCCUPANCY CLASSIFICATION:ASSEN,"BLY-3& BUSINESS 2.OCCUPANT LOAD: SEE CHARTS ON PAGE A-101 EMERGENCY LIGHT SCALE: 1/4" = 1'-0" 3.CONSTRUCTION TYPE:TYPE 5a 4. HANDICAP BATHR00711 TO BE RENOVATED, HANDICAP ACCESSIBLE COUNTER, NEW ® PORTASLE FIRE HANDICAP RAINIP. F•E EXTINGUISHER 5. EXISTING BATHROOMiS TO HAVE GENDER LABELS AS NOTED ON PLANS.SEE PAGE SD DATE: 09.05.23 A-101 FOR VATHROON1 COUNT CHART. Co SMOKE&CO DETECTOR STORAGE Co.SEE PLANS FOR SP,^OI(E/CO DETECTORS,FIRE EXTINGUISHER LOCATIOPtS,TRAVEL LOFT ENDLESS ROUND 00 DISTAN:;ES, EXIT SIGNS, HALLV.'AY WIDTHS, Era"ERGENCY li-LU"#RIP.ATIO"d LOCATIONS. DRAWN BY: Z.E.N. GOLF SD x 7. NEW BUILDING OWNER OFFICE SPACE IS AN AS BUILT CONDITION. LESS THE EXISTJ^,'G STUD t".'ALL NEW STORAGE ca O �,. N•E1'm DOOM EXIST. DOO'2 BAT. ROO",'.. BATHROOM TO BE ENLARGED TO I'o'.EET[CC/ANSI REQUIREMENTS. NEW STUD WALLS (NO PUBLIC ACCESS) 8. EXISTING FIRE ALARM SYSTEM' V"FILL BE UPDATED PER 2020 NYS BUILDING CODE REQUIREr,`NTS.SEPARATE FIRE F,Lt'.RN," PLANTS TO BE PROVIDED BYALARM 2HOURFIRESEPARATE WALL COP."PANY. 9. EGRESS DOORS TO BE EQUIPPED tVATH PANIC HARDIVARE AS PER 2020 NYS �j BUILDING CODE SECTION 1010.1.10. FIRST FLOOR VG LOFT .� &n d waYk PLANS DN � new ct n A_.CeS S ha-< < Cb nr1 sp � � k i 0 5 25 ZEN DESIGN BUILDING OWNER STORAGE SPACE 1250 EVERGREEN DRIVE (UNFINISHED) UTCHOGUE, NY 11935 PHONE: 631.513.6589 UP These plans are copyrighted and are subject to copyright protection as an"architectural work"under Sec.102 of the Copyright Act,17 U.S.O.as amended December 1990 and known as Architectural Works Copyright Protection Act of 1990.The protection includes but is not limited to the overall form as well F.E. as the arrangement and composition of spaces and elements of design.Under such protection,unauthorized use of these plans, So work or home represented,can legally result in the cessation of ZCO construction or buildings being seized and/or monetary compensation to ZEN DESIGN LLC. NO. ISSUE DATE 01 REVIEW SET 01.15.23 02 REVIEW SET 2 01.17.23 03 USE CHANGE PERMIT 02.22.23 04 BUILDING PERMIT 07.21.23 05 REVISIONS 08.07.23 06 REVISIONS 08.25.23 07 REVISIONS 08.30.23 08 REVISIONS 09.01.23 ENDLESS ROUND GOLF 09 REVISIONS 09.05.23 BASEMENT STORAGE SPACE (UNFINISHED) ."BRED ARC, NET Z �l �! TF OF N E"N 40 UP ENDLESS ROUND GOLF 7785 MAIN ROAD MATTITUCK, NY 11952 LEGEti'J S.C.T.M. # 1000 - 122 - 06 - 29.1 EMERGENCY LIGHT SCALE: 1/4" = 1'-0" PORTAELE FIRE F.E.® EXTINGUISF1'-7R 5D DATE: 09.05.23 CO SMOKE&CO DETECTORI' A DRAWN BY: Z.E.N. EXISTf"dGSTUD WALL NIEV!D0071 EXIST. DOOR K—M' STUD VALLS 2 HOUR FIRE SEPARATE I".'ALL BASEMENT PLAN , . 0 5 25 Li ON BAY 1 BAY 2 BAY 2 EXISTING BUILDING OWNER LOUNGE ZEN DESIGN OFFICE SPACE 1250 EVERGREEN DRIVE CUTCHOGUE, NY 11935 PHONE: 631.513.6589 BAY 1 _ LOUNGE These plans are copyrighted and are subject to copyright protection as an"architectural work"under Sec.102 of the Copyright Act,17 U.S.O.as amended December 1990 and known COVERED as Architectural Works Copyright Protection Act of 1990.The C VESTIBULE PORCH protection includes but is not limited to the overall form as well as the arrangement and composition of spaces and elements of UTILITY design.Under such protection,unauthorized use of these plans, NEW UNISEX CLOSET work or home represented,can legally result in the cessation of construction or buildings being seized and/or monetary HC BAH _ compensation to ZEN DESIGN LLC. ® NO. ISSUE DATE AS BUILT BUILDING ENDLESS STAIRS OWNER 01 REVIEW SET 01.15.23 OFFICE ROUND GOLF UP TO LOFT OFFICE (NO PUBLIC ACCESS) 02 REVIEW SET 2 01.17.23 SPACE 03 USE CHANGE PERMIT 02.22.23 FOYER 04 BUILDING PERMIT 07.21.23 05 REVISIONS 08.07.23 L= UNISEX x 06 REVISIONS 08.25.23 AS BUILT BATH 1 _ 07 REVISIONS 08.30.23 STORAGE � � `',. 08 REVISIONS 09.01.23 CLOSET - -� - 0 09 REVISIONS 09.05.23 IL WOMENS MENS z LOCKER LOCKER 0 (� I ) ROOi�71 R001�12 W l U NEW PUTTING GREEN UNISEX HC tLil—I BATHROOMUNISEX O OO 00 BATH 2 00 j JANITORS O ENDLESS — _ CLOSET R STORAGE OUND GOLF _ SPACE --- , UNISEX HC BATHROOM a i COVERED PORCH BAY 3 LOUNGE IL BAY—4 1 OUNG t BAY 4 LOUNGE ENDLESS BAY 4 BAY 3 �� 04 4 42'' 40 ROUND GOLF �TF OF N V OFFICE SPACE 1 FIRST FLOOR PLAN ENDLESS ROUND i GOLF 7785 MAIN ROAD MATTITUCK, NY 11952 S.C.T.M. # 1000 122 - 06 - 29.1 BUILDING TENANT ENDLESS ROUND GOLF - GROUP (A-3) ASSEMBLY IN. TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES SCALE: 1/4" = 1'-0" PACE SQUARE FEET OCCUPANCY LOAD OCCUPANCY LOAD BSMNT11 FF I LOFT FACTOR BUILDING TENANT ENDLESS ROUND GOLF - GROUP (A-3) ASSEMBLY ASSEMBLY:STANDING SPACE 174 SF 15 NET 12 PERSONS ) 8 PERSONS MAX PER DESCRIPTION WATER CLOSETS LAVATORIES PROVIDED DATE: 09.05.23 ASSEMBLY: 2156 SF(4 BAYS)+ SIMULATOR BAY+ 36 PERSONS STORAGE 3 WATER CLOSETS GOLF SIMULATOR&PUTTING GREEN 259 SF(PUT.GREEN) 4 ADDITIONAL FOR LOFT ENDLESS ROUND ASSEMBLY.GAMING AREAS 1 PER 100 MALE 1 PER 250 PROVIDED MEETS DRAWN BY: Z.E.N. PUTTING GREEN GOLF 1 PER 50 FEMALE REQUIREMENTS BUSINESS(OFFICE) 162 SF 150 GROSS 2 PERSONS STORAGE LOCKER ROOMS 234 SF 50 GROSS 5 PERSONS (NO PUBLIC ACCESS) BUILDING OWNER - GROUP (B) BUSINESS ACCESSORY STORAGE(S-1.) 5172 915 SF 692 SF 300 GROSS 23 PERSONS DESCRIPTION WATER CLOSETS LAVATORIES PROVIDED CIRCULATION 90 SF 858 SF 46 SF — 0 PERSONS 1 WATER CLOSET 1 PER 25 FOR FIRST PROPOSED BATHROOM/UTILITY 184 SF — 0 PERSONS BUSINESS:OFFICE BUILDINGS 50 1 PER 40 PROVIDED MEETS FIXED FURNITURE 29 SF — 0 PERSONS REQUIREMENTS 78 TOTAL PERSONS OCCUPANCY DIAGRAM • DN BUILDING OWNER - GROUP (B) BUSINESS SPACE SQUARE FEET OCCUPANCY LOAD FACTOR OCCUPANCY LOAD BUSINESS(OFFICE) 698 SF 150 GROSS 5 PERSONS STORAGE(S-1) 688+42 SF 300 GROSS 3 PERSONS _ CIRCULATION 67 SF - 0 PERSONS 0 5 25 BATHROOM/UTILITY 45 SF — 0 PERSONS LOFT PLAN 2 8 TOTAL PERSONS ZEN DESIGN BUILDING OWNER STORAGE SPACE 50 EVERGREEN DRIVE (UNFINISHED) TCHOGUE, NY 11935 PHONE: 631.513.6589 UP These plans are copyrighted and are subject to copyright protection as an"architectural work"under Sec.102 of the Copyright Act,17 U.S.O.as amended December 1990 and known as Architectural Works Copyright Protection Act of 1990.The protection includes but is not limited to the overall form as well as the arrangement and composition of spaces and elements of design.Under such protection,unauthorized use of these plans, work or home represented,can legally result in the cessation of construction or buildings being seized and/or monetary compensation to ZEN DESIGN LLC. NO. ISSUE DATE 01 REVIEW SET 01.15.23 02 REVIEW SET 2 01.17.23 03 USE CHANGE PERMIT 02.22.23 04 BUILDING PERMIT 07.21.23 05 REVISIONS 08.07.23 06 REVISIONS 08.25.23 07 REVISIONS 08.30.23 08 REVISIONS 09.01.23 ENDLESS ROUND GOLF 09 REVISIONS 09.05.23 BASEMENT(UNFINISHED) i �S.RED ARC Nrt' Z �i s� 0 4 4 4 2'b OF NS11N UP ENDLESS ROUND GOLF 7785 MAIN ROAD MATTITUCK, NY 11952 S.C.T.M. # 1000 122 - 06 - 29.1 BUILDING TENANT ENDLESS ROUND GOLF - GROUP (A-3) ASSEMBLY SPACE SQUARE FEET OCCUPANCY LOAD OCCUPANCY LOAD SCALE: 1/4" = 1'-0" BSMNTJ FF I LOFT FACTOR ASSEMBLY.STANDING SPACE 174 SF 15 NET 12 PERSONS 8 PERSONS MAX PER DATE: 09.05.23 ASSEMBLY: 2156 SF(4 BAYS)+ SIMULATOR BAY+ 36 PERSONS GOLF SIMULATOR& PUTTING GREEN 259 SF (PUT.GREEN) 4 ADDITIONAL FOR PUTTING GREEN DRAWN BY: Z.E.N. BUSINESS(OFFICE) 162 SF 150 GROSS 2 PERSONS LOCKER ROOMS 234 SF 50 GROSS 5 PERSONS ACCESSORY STORAGE(S-1) 5172 915 SF 1692 SF 300 GROSS 23 PERSONS CIRCULATION 90 SF 1858 SF 146 SF - 0 PERSONS BATHROOM/UTILITY 184 SF - 0 PERSONS PROPOSED FIXED FURNITURE 29 SF - 0 PERSONS 78 TOTAL PERSONS OCCUPANCY DIAGRAM BUILDING OWNER - GROUP (B) BUSINESS SPACE SQUARE FEET OCCUPANCY LOAD OCCUPANCY LOAD FACTOR BUSINESS(OFFICE) 698 SF 150 GROSS 5 PERSONS STORAGE(S-1) 688+42 SF 300 GROSS 3 PERSONS i CIRCULATION 67 SF - 0 PERSONS {, BATHROOM/ UTILITY 45 SF - 0 PERSONS 8 TOTAL PERSONS