Loading...
HomeMy WebLinkAbout49138-Z a�o�SUFFOLKCppy` Town of Southold 1/27/2024 P.O.Box 1179 y 53095 Main Rd Woy�o� �ap� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 4490 Date: 1/27/2024 THIS CERTIFIES that the building ALTERATION Location of Property: 7130 Route 25,East Marion SCTM#: 473889 Sec/Block/Lot: 31.-6-6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/16/2023 pursuant to which Building Permit No. 49138 dated 4/19/2023 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations, including front and rear deck repairs,to existing single-family dwelling as applied for. The certificate is issued to Fisher RA Rev Trust of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 49138 1/3/2024 PLUMBERS CERTIFICATION DATED 10/16/2023 KillianGremler Au ri d S afore SUF Fat/r� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 49138 Date: 4/19/2023 Permission is hereby granted to: Bjornholm, William 7130 Main Rd East Marion, NY 11939 To: construct alterations to existing single-family dwelling as applied for. At premises located at: 7130 Route 26, East Marion SCTM #473889 Sec/Block/Lot# 31.-6-6 Pursuant to application dated 3/16/2023 and approved by the Building Inspector. To expire on 10/18/2024. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $379.60 CO-ALTERATION TO DWELLING $50.00 Total: $429.60 Bui ing Inspector pf SO(/T�QIo Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 i� sean.devlin0-town.southold.nv.us Southold,NY 11971-0959 cOOMY,�c� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: William Bjornholm Address: 7130 Route 25 city East Marion st: NY zip: 11939 Building Permit#: 49138 section: 31 Block: 6 Lot: 6 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: REP Electric License No: 46288ME SITE DETAILS Office Use Only Residential X Indoor N Basement X Service Commerical Outdoor 1st Floor X Pool New X Renovation 2nd Floor x Hot Tub Addition Survey Attic X Garage INVENTORY Service 1 ph Heat Duplec Recpt 43 Ceiling Fixtures 9 Bath Exhaust Fan 3 Service 3 ph Hot Water GFCI Recpt 4 Wall Fixtures Smoke Detectors 4 Main Panel A/C Condenser Single Recpt Recessed Fixtures 57 CO2 Detectors Sub Panel A/C Blower Range Recpt Gas Ceiling Fan 2 Combo Smoke/CO 3 Transfer Switch UC Lights Dryer Recpt Gas Emergency Strobe Heat Detectors Disconnect Switches 33 4'LED Exit Fixtures Sump Pump Other Equipment: Hood, Oven, DW, Fridge, Micro, W/D Notes: Two Story w/ Unfinished Basement Inspector Signature: 1E 2r Date: January 3, 2024 S. Devlin-Cert Electrical Compliance Form so Toxu Hall Am 11 �; Tckpimc(631)765-1802 54375 Main Road '" Fnz(631)765-9542 . P.O.Elox.d,A79 (�l Sswlh 1`aid,N11973-0959 - ` (�} C La I w ' HWLbING DEPARTMENT � J A N 2 2 2024 , - U TOWN OF SOLPMOLD Building Department Tov.n of Southold Date: [ L Building Permit No. Owner. ,-r / rn�tI't p Pam) Plumber., i�3' 1.Y._1 t 'f` t �`.. (Please Prw) I certify that the solder used in the"water supply system contains less than VIO of 1% lead. � r '(Plgmbcis'Signahue) Swom to before me this dayoff O&1r&t . 20_,,' Notary Public, Ji4 - G Co dy LIN0.4 S MANNINO Notari Pubic,S+.ai�of NgwYe:k ftcgi,l aAor.No 4 W 85U5 QUa:.fiei:7S o'k Co,my -ry C.tsYrtni;,vian cn:ucs �l'f(,J1.Z„1 0��0 5o�yo6 49 l�3 6 '7 P 3D --�-�s * TOWN OF SOUTHOLD BUILDING DEPT. `"rouxn ' 631.765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) 1,4DELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: nrAL-, DATE INSPECTOR �aoe souryo f # TOWN OF SOUTHOLD BUILDING DEPT. rouse 631.765.1802 INSPECTION [ ] FOUNDATION 1ST [/ROUH PLEIG. FOUNDATION 2ND [ ATIOWCAULKING FRAMING /STRAPPING [ [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ell "� D DATE TA INSPECTOR I �o��OF SOUTyo6 yR r �� --7 1 '3a <R4-�Z� * TOWN OF SOUTHOLD BUILDING DEPT. 631.765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) f '"'T�'^"' Tt'"'"' ` [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE 2 INSPECTOR _C _ P �'�V ho�a0f SOUTy�G # TOWN OF SOUTHOLD BUILDING DEPT. `"courm " 631.765.1802 INSPEC ION [ ] FOUNDATION 1ST ROUGH PLEIG. [/OUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] P /O [ ] RENTAL V*REMARKS: ( — fe ))w�, P-vrv5o K 1 ✓ 4 , V✓WI nY O W DATE y INSPECTOR # TOWN OF SOUTHOLD BUILDING DEPT. 631.765.1802 INSPECTION [ ] FOUNDATION 1ST [ io,,R6uGH PLBG. [ ] FOUNDATION 2ND [ INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMA KS: (AM( AeL—, Q DATE INSPECTO FIELD INSPECTION REPORT DATE COMMENTS ro FOUNDATION (1ST) � "n x ------------------------------------ FOUNDATION (2ND) IIAA z � o VV Il .1e tv Sh✓� ROUGH FRAMING& PLUMBING 1 N � IL la3 LAI in v` C� & -t r INSULATION PER N.Y. e Nvcaly STATE ENERGY CODE Y M Yq\ GO i S FINAL " ADDITIONAL COMMENTS Vv 4 Tn 1. ss Aa.. a�9• G a 8/�ca «w /0 3/9 G KI ZS P0. loL ¢. 19b.qD re c 4# o fi0 I S 2L4 k00 - a. m A' 3 � X 4 ro Cs� �z x e ro y TOWN OF SOUTHOLD—BUILDING DEPARTMENT ® Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 h"s://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: MAR 16 2023 LD Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner;an 8UIWINb OFPT. Owner's Authorization form(Page 2)shall be completed. 70VVN OFS011THOLD Date: OWNER(S)OF PROPERTY: Name:Ronald A. Fisher sCiM#1Og0-1000 - 31. - 6 - 6 Project Address:7130 Main Road, East Marion, NY 11939 Phone#:914 714 4859 1Email:ronfis@aol.com Mailing Address:PO Box 447, Orient, NY 11957 CONTACT PERSON: Name: same as Owner Mailing Address: same as above Phone#:same as above Email:same as above 6ESIG14'PROFESSI6NAL INFORMATION: Name:Hideaki Ariizumi, 'studio a/b architects Mailing Address:PO Box 444, .Orient, NY 11957 Phone#:631 323 1.426 Email:hideaki@st'udioabarchitects.com CONTRACTOR INFORMATION: Name: (not yet selected) Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRucnoN []New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION „ Existing use of property:Single Family Dwelling Intended use of property:Same Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R40 this property? ❑Yes BNo IF YES, PROVIDE A COPY. ❑ Check BOX After Reatiing: The,owner/contractor/desiggprofessional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.'APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and othei applicable laws,Ordinances or Regulations,for the constfuction of buildings,, 'additions,alterations or for removalbr demolition as herein'described.The applicant agrees to comply with all applcable laws,ordinances;Uuilding code,.. ,'' .housing toile and regulations and to admit authorized inspectors on premises and in buildings)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor.pursuant to_Sectioo 210.45of the New Yolk State Penal law. - • ',.' "�. ,u Application Submitted By(print e): g,,,trv6. A. ❑Authorized Agent *-Wner Signature of Applicant: Date: 37 STATE OF NEW YORK) l SS: COUNTY OF SU 1�1< 1 R©n o., being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the 0 w N IL-(Z— k (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief, and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this -Ift. day of H 20 V) otary Publi JEANMARIE CiDDON PROPERTY OWNER AUTHORIZATION Notary No.Oio,State of New York o.010D6251238 (Where the applicant is not the owner) Oualifieq in Suffolk County i1 Gemml®nlon ExpIrBB November14,20 I,. residing at do hereby authorize to apply on my behalf to the ToWn-of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 ��O�g�fFO(,�coGy BUILDING DEPARTMENT-:Electrical Inspector TOWN OF SOUTHOLD coi Town Hall Annex-54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 4j a0 Telephone (631) 765-1802 - FAX (631) 765-9502 rooerrODsoutholdtownnv.00v— seandOsoutholdtownnv oov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ail Information Required) Date: 6/13/2023 Company Name: REP Electric LLC Electrician's Name: Robert E Palladino License No.: 46288ME Elec. email:REPelectric1@gmail.com Elec. Phone No: 631-767-6034 01 request an email copy of Certificate of Compliance Elec. Address.: PO Box 635 Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Fisher Address: 7130 Route 25 East Marion Cross Street: Gillette Dr Phone No.: Bldg.Permit#: 49138 email: Tax Map District: 1000 Section: Block: Lot: P' BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Alteration U�� •�� Square Footage: 1566 Circle All That Apply: Is job ready for inspection?: ❑ YES Q NO •Rough In ❑ Final Do you need a Temp Certificate?: YES R] NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals n 1 2 H Frame n Pole Work done on Service? nY nN Additional Information: PAYMENT DUE WITH APPLICATION (p I I`I 23 o4!R 01 sgl:04 BUILDING DEPARTMENT- Electrical Inspector C�GtA TOWN OF SOUTHOLD q a Town Hall Annex- 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 1 rogerr a)southoldtownny.gov — seand(a)southoldtownny.dov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 6/13/2023 Company Name: REP Electric LLC Electrician's Name: Robert E Paladino License No.: 46288ME Elec. email:REPelectricl@gmaii.com Elec. Phone No: 631-767-6034 01 request an email copy of Certificate of Compliance Elec. Address.: PO Box 635 Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: Fisher D r yt Vve I 1M Address: 7130 Route 5 East Marion Cross Street: Gillette Dr Phone No.: Bldg.Permit#: 49138 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Alteration Square Footage: 115Q6 Circle All That Apply: Is job ready for inspection?: YES ❑✓ NO ✓ Rough In Final Do you need a Temp Certificate?: ❑ YES a NO Issued On Temp Information: (All information required) Service SizeEl1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals M 1 FJ2 H Frame M Pole Work done on Service? Y FIN Additional Information: .el 56 , PAYMENT DUE WITH APPLICATION PERMIT ,tI' ��LyV�,�`�'` ? Address Switches IJ Outlets I 9 t 1 L GFI's Surface Sconces HH's UC Lts 1q Fans �\ Fridge HW Exhaust Oven AV W/D ( ,e/ii, J r 1 Smokes DW I Mini Carbon 1 Micro Generator Combo i�` Cooktop Transfer 4C \ AH Hood p Service IAmps Have Usec ;penal: :omments } Bunch, Connie From: Even Keel Home Services <evenkeel@evenkeelhome.com> Sent: Saturday,January 20, 2024 10:33 AM To: Bunch, Connie Subject: [SPAM] - Attachments: Fisher-Solder Cert.pdf Connie, Attached, please-see the solder certificate for 7130 Main Rd, East Marion. John was at the house for the final inspection on 1/17/24 and asked me to send it to you. Please let me know if you need anything else. Building Permit#: 49138 Regards, Wayde Bennett Even Keel Home Services, Inc 631.323.5194 www.evenkeelhome.com ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 1 Certifications indicated hereon signify that this plat of the properly depicted hereon was made in accordance with the existing Code of Practice for land Surveyors adopted by the New York State Association of Professional Land Surveyors. This cedification is only for the lands depicted hereon and is not certification of tide,zoning or freedom of encumbrances. Said certifications shall run only to the persons and/or entities listed hereon and are not transferable to additional persons,entities or subsequent owners. MAIN ROAD N 56'13'50" E 98.26' OHS H� OH MONUMENT FOUND : WELL° M FOUND T — HEAD 14488.61' 1 ___ 0 1 I 1 1 1 COVERED PORCH I W 31.6' l ^ 1 I pai' 2 STORY aM4,0• DWELLING ry W I a I NO. 7130 " UNIT J 1 1 I11.1, 6.2 ❑ !D J 1 I 12.2' O1 11 O O GRAVEL J a 1e 0 N 1 I " "GENERATOR Q a I 0 I_ CIE 0 3 I 1 �I 14,6' W W O } CCOVERED, U ^4 1 1 4 PORCH J 3 Y I 1 I p0 GARDEN MAAONRY.:::•. P o � I 1 I 3 I• ••'••12.2 1 v to I :'Q " o b NN 1 I e 0 1 Y N 1 I I 1 STORY 20.e1 1 H 1 J BUILDING I N 59049'00" E 16.82' MONUMENT MONUMENT 1 FOUND FOUND 0.3'N—_ � a ^ O WIRE°FENCE O n, CATS FE ±, tY O 3S•W 4 0 Pill Z " 1 O t ° 10 1 I i I GARDEN FE N O rWALL 3.0'W 1 N O O SHED N p� SL O—O 0� LL 0 N 2 0 1 4LJNE AR MONUMENT fEND ' FOUND 25E O—O—OOOVINri FENCE S 0 2.4'S S 59'32'30" W I 116.18' TAX LOT 5.1 I W SURVEY YEW: SURVEY © 2022 BBV PC The offsets or dimensions shown from structures to the properly lines are for a specific purpose and use,and therefore,are not intended to guide in the erection of fences,retaining walls,pools,patios,planting areas,additions to buildings and any other construcnon. Subsurface and environmental conditions were not examined or considered as a pan of this survey.Easements,Rights-of-Wary of record,if any,are not shown.Properly corner monuments were not placed as a pan of this survey. Barrett Tax Map: DISTRICT 1000 SECTION 31 BLOCK 6 LOT 6 BBB! Bonacci & Map of: PROPERTY Unauthorized of rection er209ofr addition to this survey isa yo aw t Unan of section 72g9 of New Yo is Education Irnv Van-Wee e, PC Map Lot: -- Map Block: -- Engineers e Surveyors . Planners 175A Commerce Drive Hauppauge,NY 11788 File Date: -- File No.: -- County: SUFFOLK T631.435.11 www.6 a c.c A35.1022 Situate: EAST MARION,TOWN OF SOUTHOLD \ www.bbvpc.com 1 1 1 Certified to: Tide No.: 7404-015302 Date By Revision \U1J RONALD FISHER Copies of this survey map not bearing the land surveyor's embossed seal and signature shall not FIDELITY NATIONAL TITLE INSURANCE COMPANY be considered to be a true and valid copy surveyed by: C.S. Drafted b : A.V.R. Checked by: C.W. project No.: A220599 Date: NOVEMBER 14 2022 Scale: 1"= 30' PROJECT GENERAL NOTES: BUILDING DEPARTMENT NOTES: LIST OF DRAWINGS: studio a/b architects Alteration to Fisher Residence THE FOLLOWING NOTES SHALL APPLY THROUGHOUT. EXCEPTIONS ARE SPECIFICALLY NOTED ON THE FOLLOWING NOTES SHALL APPLY THROUGHOUT. EACH DRAWINGS. 1 /14 T.01 TITLE SHEET 651 West Main Street, 1. ALL WORK SHALL BE EXECUTED IN FULL COMPLIANCE WITH THE APPLICABLE PROVISIONS OF ALL 2 /14 A.01 Site Plan, Demolition Plans Riverhead, NY 11901 1. ALL WORK OF THIS CONTRACT SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF LAWS, BY-LAWS, STATUTES, ORDINANCES, CODES, RULES, REGULATIONS, AND LAWFUL ORDERS 3 114 A.02 Floor Plans 631 5912402 Owner: THE NEW YORK STATE (NYS) RESIDENTIAL CODE OF PUBLIC AUTHORITIES BEARING ON THE PERFORMANCE AND EXECUTION OF THE WORK. 4 114 A.03 Elevations 631 3231426 Ronald A. Fisher NYS EXISTING BUILDING CODE THE CONTRACTOR SHALL PROMPTLY NOTIFY THE TOWN AND ARCHITECT/ENGINEER OF ANY 5 /14 A.04 Building Section glynis@studioabarchitects.com NYS ENERGY CONSERVATION CONSTRUCTION CODE PORTIONS OF THE WORK IN THE CONTRACT DOCUMENTS THAT ARE AT VARIANCE WITH THE 6 /14 A.05 Schedules mailingaddress: 32615 Main Road, Box 447 NYS FIRE CODE ABOVE. Orient NY 11957 NYS PLUMBING CODE 2. ALL MATERIALS; ASSEMBLIES, FORMS METHODS OF CONSTRUCTION AND SERVICE EQUIPMENT 7 /14 A.06 Typical Thermal Protection Details PO Box 444, Orient, NY 11957 Phone: 914 714 4859 NYS MECHANICAL CODE SHALL MEET THE FOLLOWING REQUIREMENTS: 8 /14 A.07 Bathroom Details e-mail: ronfis@aol.com NYS FUEL GAS CODE a) THEY SHALL HAVE BEEN ACCEPTABLE TO THE SOUTHOLD BUILDING DEPARTMENT. 9 114 A.08 Built-in Details APPLICABLE SUFFOLK COUNTY HEALTH REGULATIONS AND STANDARDS b) THEY SHALL HAVE BEEN ACCEPTED FOR THE USE UNDER THE PRESCRIBED TEST METHODS BY 10 114 S.01 Structural Notes client: TOWN OF SOUTHOLD REGULATIONS THE REGULATING AGENCIES. 11 /14 A.09 Built-in Details 2 Site Address: OTHER AGENCIES HAVING JURISDICTION ON THE WORK OF THIS CONTRACT, 3. MATERIALS OR ASSEMBLIES REQUIRED TO HAVE A FIRE RESISTANCE RATING SHALL COMPLY 12 /14 MP.01 Mechanical and Plumbing Notes, Plumbing Layouts APPnOAl2D AS NOTED Ronald A. Fisher 7130 Main Road, WITH ONE OF THE FOLLOWING: 2. DRAWINGS ARE NOT TO BE SCALED. USE DIMENSIONS ONLY,ALL DIMENSIONS AND CONDITIONS a) THEY SHALL CONFORM WITH EITHER THE APPLICABLE CODES OR 13 /14 S.02 Decking Layouts DATE: B P # 3� site address.- East Marion, NY 11939 SHOWN AND ASSUMED ON THE DRAWINGS MUST BE VERIFIED AT THE SITE BY THE CONTRACTOR b) THEY SHALL HAVE BEEN TESTED IN ACCORDANCE WITH ASTM El19, STANDARD METHODS OF 14 114 E.01 Electrical Layout 7130 Main Road, East Marion, NY 11939 BEFORE ORDERING ANY MATERIAL OR DOING ANY WORK. ANY DISCREPANCIES IN THE DRAWINGS FIRE TESTS OF BUILDING CONSTRUCTION AND MATERIALS AND ACCEPTED BY THE SOUTHOLD FEE: - ay ___`11 tel: 914 714 4859 Tax Map. AND SPECIFICATIONS SHALL BE REPORTED TO THE ARCHITECT. NO CHANGE IN DRAWINGS OR TOWN BUILDING DEPARTMENT NOTIFY SUILC,!iN,, ^t, ;T IAENT AT email: ronfis@aol.com 1000-31. -6-6 SPECIFICATIONS IS PERMISSIBLE WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT/ENGINEER. (OR) 76 -1802 8 A' 'R G w F.: _ FOR THE NO WORK SHALL PROCEED UNTIL SUCH DISCREPANCY HAS BEEN RECTIFIED. c THEY SHALL HAVE BEEN ACCEPTABLE PRIOR TO THE EFFECTIVE DATE OF THE CODE. r 0'._LOWING i,';�;;'�(;�j;:;�.,� tax map#: 1000-31.-6-6 architect: 4. THE CONTRACTOR SHALL OBTAIN EQUIPMENT USE PERMITS REQUIRED IN ACCORDANCE WITH t FO(J','pe? 3. THE ARCHITECT/ENGINEER HAS INDICATED AND ESTIMATED CERTAIN CONDITIONS EITHER NOT THE BUILDING CODE. P � -�aUiRcD studio a/b architects SHOWN OR NOT CONSIDERED RELIABLE ON OLDER DRAWINGS FURNISHED TO THE ARCHITECT, OR 6. ALL NEW INTERIOR WALL AND CEILING FINISHES SHALL HAVE A FLAME-SPREAD CLASSIFICATION OF FOR t O- F;3j j1' E 24190 Main Road, PO Box 444 NOT MEASURABLE DUE TO ABSENCE OF DRAWINGS, OR INACCESSIBLE TO VERIFY IN THE FIELD NOT GREATER THAN 200, SMOKE-DEVELOPED INDEX OF NOT GREATER THAN 450, AS PER[SECTION 4. ROUf�H - FR�!.t!°.;;; & PLLMB!NG Orient, NY 11957 PRIOR TO PREPARING THE DRAWINGS. R302.9 (NYS RESIDENTIAL CODE)] [SECTION 803(NYS BUILDING CODE)]. INSULATION T: 631 323 1426 8. ALL NEW THERMAL AND SOUND-INSULATING MATERIALS SHALL COMPLY WITH [SECTION R302.10 (NYS r'!!-.AL ' CU^!C; � I^N MUST a. ALL WORK ON THESE DRAWINGS SHALL BE CONSIDERED NEW WORK WHETHER STATED OR NOT, RESIDENTIAL CODE SECTION 807 NYS BUILDING CODE E k00MPL!--T' e-mail: glynis@studioabarchitects.com )] [ ( )]. Y, L-lL' i' '=; G{�• EXCEPT WHERE SPECIFICALLY NOTED AS "EXISTING TO REMAIN". 9 THE CONTRACTOR IS RESPONSIBLE FOR FILING APPLICATIONS AND OBTAINING PERMITS FOR ALL CONS Tr?UCTICN! SHf.LL MEET THE PLUMBING SCAFFOLDING,ANY OTHER CONSTRUCTION EQUIPMENT OR PUBLIC PROTECTIVES REQUIRED TO REO;IRtMEht i i C F i HF%ODES OF NEW ALl PLUMBING WASTE ;• COORDINATION OF ALL WORK UNDER THIS CONTRACT SHALL BE MAINTAINED TO ENSURE THE ENSURE SAFETY OF OPERATION. YORK STATE. NOT RESPONSIBLE FOR &WATER LINES NEED` Ql1��l_ITY AND TIMELY COMPLETION OF THE WORK/PROJECT. DES!GN OR CONSTRUCTION ERRORS. i' yNG.,BEFOR�COYEn* .` 6. THE CONTRACTOR SHALL DISCONNECT AND/OR REMOVE ANY EXISTING PLUMBING, ELECTRICAL FIXTURES, WIRE CONDUITS, OR OTHER WORK WHICH MIGHT INTERFERE WITH THE WORK OF THIS CONTRACT. COMPLY WITl-i ALL CODES OF ZONING: ��rTT , 7. HE CONTRACTOR SHALL PATCH AND REPAIR ALL DAMAGED OR EXPOSED SURFACES DUE TO ��-�' '�'` • ' = = TJk'W�'.� COD ES "i CONTRACT WORK. ALL NEWLY INSTALLED, PATCHED WORK AND ALL AFFECTED AREAS SHALL BE ZONED: R40 /t, , (,;a;;, t,°�,,�i `;r.;t,i [� ;�°�aS o FINISHED SO THAT THE ENTIRE HORIZONTAL OR VERTICAL SURFACE TO THE CLOSEST CORNER IN REQ. EXISTING PROPOSED ALL FOUR DIRECTIONS MATCHES SCHEDULED CONDITIONS. LOT AREA ................................ 40,000 .................... 28,0 ................... NC, AS EXISTING LOT WIDTH ............................... 150 ......................... 98.3 N/C, AS EXISTING 3'l"-='�`1hiiNu EvARD 8. FURNISH ALL NECESSARY NEW MATERIALS AT NO ADDITIONAL COST TO THE CLIENT FOR THE ......••.••.••.... All exterior lighting LOT DEPTH ............................... 175 ......................... 269.6 .................... AS EXISTING FOLLOWING CONDITIONS: FRONT YARD ........................... 50 ........................... 30.2 .................... NC, AS EXISTING installed, replaced or...- .. -....•,. 1;,v II a) ANY ALREADY COMPLETED WORK THAT HAS BEEN REMOVED OR DAMAGED IN ORDER TO 1 SIDE YARD ............................ 15 ........................... 12.2 ...................... NC, AS EXISTING ram""` repaired shall conform PERFORM THE CONTRACT WORK. p 2 SIDE YARDS ........................... 35 ........................... 60.8 ................... AS EXISTING b) TO FURNISH THE WORK OF THIS CONTRACT IN WORKMANLIKE MANNER. REAR YARD ............................. 50........................... 173.2 .................... AS EXISTING to Chapter 172 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL LIVABLE FLOOR AREA............ 850 MIN. ................ of the Town Code BUILDING AREA................................ HOUSE 1,119.83 NO CHANGE FRONT PORCH 196. WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTIONS AND OFF 6.75NO CHANGE OCCUPANCY OR � ALIGNMENTS ACCORDING TO CODES AND STANDARDS OF GOOD PRACTICE. REAR PORCH 107.96 NO CHANGE I SHED 423.84 NO CHANGE 10. DETAILS NOT SHOWN OR SPECIFIED BUT NECESSARY RY FOR PROPER AND ACCEPTABLE TOTAL 1,848 38 NO CHANGE USE IS UNLAWFUL CONSTRUCTION INSTALLATION OR OPERATION OF ANY PART OF THE WORK AS DETERMINED BY o 0 COVERAGE ............................... 35 MAX. ............. 26' + NO CHANGE �'!fTHOUT CERTIFICATE CLIENT OR ARCH ITECT/ENGINEER SHALL BE INCLUDED IN THE WORK THE SAME WAY AS IF HEREIN HEIGHT IN FEET....................... 35 MAX. ................. 26' +/- NO CHANGE SPECIFIED OR INDICATED. HEIGHT IN STORY ................. 2 1/2 MAX. ...;......... 2 AS EXISTING �! No. Description Date ACCESSORY BUILDING 11. WHERE MANUFACTURER'S NAMES AND PRODUCT NUMBERS ARE INDICATED ON DRAWINGS, IT OF OCCUPANCY Y SHALL BE CONSTRUCTED TO MEAN THE ESTABLISHMENT OF QUALITY AND PERFORMANCE SIDE YARD ................................. 5 MIN. ................. 20.8 AS EXISTING STANDARDS OF SUCH ITEMS. ALL OTHER PRODUCTS MUST BE SUBMITTED TO THE ARCHITECT FOR REAR YARD ............................. 5 MIN. 134.7 AS EXISTING '' t=" p[l�',IOFF APPROVAL BEFORE THEY SHALL BE DEEMED EQUAL, HEIGHT ..................................... 22 ........................ 16.3 AS EXISTING "r,t)` 12. FIRE STOPPING SHALL BE INSTALLED AT ALL PENETRATIONS OF FIRE RATED CONSTRUCTION AS BUILDING AREA........................ 660 ......................... 423.8 AS EXISTING f [t,c i L r.iV UiiUE. PER SPECIFICATIONS. 13. SIZE OF MASONRY UNITS AND WOOD MEMBERS ON PLANS, BUILDING ELEVATIONS AND SECTIONS ARE SHOWN AS NOMINAL SIZE. COMPLIANCE: �, DE 14. PROVIDE GUARDS, RAILS, FENCES, CATCH PLATFORMS, DECKING, NIGHT LIGHTING, ETC., AS I.) Use(s) and Occuparcy Class ification(s): Single Family Residence ] ET REQUIRED BY THE REGULATING AGENCIES TO PROVIDE ADEQUATE PROTECTION. 2.) Height and Fire Area: 26', 2 stories, as existing; Fire Area n/a 3.) Type of Constructior.,Type VB, 2x4, platform construction, as existing (i. TI lF. CONTRACTOR SHALL KEEP WORK SITE FREE FROM DEBRIS AND ACCUMULATED REFUSE, 4.) Structural Design cnleria: Engineered. AND SHALL HAVE SOLE RESPONSIBILITY FOR PROTECTING ALL DANGEROUS AREAS FROM ENTRY BY 5.) Framing elements: See Structural Drawings UNAUTHORIZED PARTIES. SITE WILL BE LEFT BROOM CLEAN AT THE END OF EACH WORKING DAY 6.) Design load calculations: See Structural Drawings SUMMARY OF WORK 7.) Glazing protection: F.equired (Wind Speed 130 mile zone; 0.3 mile(<1 mile)to coast line) 1E�. THL=�CONTRACTOR SHALL MAINTAIN FREE AND UNOBSTRUCTED ACCESS FROM ALL SPACES AND (Replaced new window shall be provided with protection panel.) THE SUMMARY OF WORK SHALL INCLUDE BUT IS NOT LIMITED TO: ADJACENT SPACES THE EXTERIOR OF THE BUILDING AT ALL TIMES. 8.) Load paths from roo to foundation: See Structural Drawings PLUMBER CERTIFICI�ATION 9.) Nailing and/or connection schedule, framing details: N/A ON LEAD CONTENT BEFORE 1. FIRST FLOOR ALTERATION 17. THE CONTRACTOR SHALL, UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS, 10.)Means of Egress (R310 Emergency Escape& Rescue Openings): N/A CERTIFICATE OF OCCUPANCY �:ECURE AND PAY FOR REQUIRED INSPECTIONS, PERMITS , FEES, LICENSE AND INSPECTIONS 1.1 CREATE SPATIAL FLOW FROM ENTRY, LIVING ROOM AND DINING BY REMOVING EXISTING PARTITIONS. r ( ) 11.)Plumbing riser diagn.m: See Plumbing Drawing 1.2 IMPROVE KITCHEN NECESSARY FOR THE PROPER EXECUTION OF THE WORK. 12.)Location of fire protection equipment, i.e. smoke alarm: See Electrical Drawings SOLDER USED IN WATER 1.3 IMPROVE EXISTING BATHROOM 13.)Truss design drawings with certification: N/A SUPPLY SYSTEM CANNOT 13. MINIMALIZATION, SEPARATION,AND RECYCLING OF WASTE ARE ENCOURAGED. 14.)Energy calculations from design professional: N/A(Prescriptive, this alteration does not use more energy than the EXCEED 2110 OF 1% LEAD. 1 2. SECOND FLOOR ALTERATION existing building) See A.06 2.1 REDUCE ONE BEDROOM. USING THE SPACE, EXPAND MASTER BEDROOM WITH A MASTER 19. THE CONTRACTOR SHALL INSTALL OWNER SUPPLIED FIXTURES, EQUIPMENT,ACCESSORIES AND BATHROOM AND CLOSET. LIKE. OTHER REGULATORY REQUIREMENTS: ABBREVIATIONS: 2.2 CREATE A STUDY, LAUNDRY CLOSET 20. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR HIS OWNER SELECT ITEMS, 2.3 IMPROVE EXISTING BATHROOM PROVIDING SAMPLES AND/OR CATALOGS, WHEN REQUIRED. Health Department: Not Required. Numbers of bedrooms are reduced AFF ABOVE FINISHED FLOOR INSUL. INSULATION 3. NECESSARY REPAIRS AND MAINTENANCE: DEC: Nd Required ALUM. ALUMINUM INT. INTERIOR BELOW IS A SUMMARY FROM THE BUILDING INSPECTION. THE CONTRACTOR SHOULD RETAIN THIS 21. ADDITIONAL NOTES WHICH ARE APPLICABLE TO THE PROJECT MAY BE FOUND THROUGHOUT THE Board of Trustee: No,Required & AND L.F. LINEAR FOOT INSPECTION REPORT FOR DETAILS. CONTRACT DOCUMENTS. Planning Board: Not Required APPROX. APPROXIMATELY L.P. LOW POINT 3.1 REPAIR WINDOWS, INCLUDING BUT NOT LIMITED TO SASH CORDS, REPAIR CRACKED WINDOWS, ZBA: Not Required ARCH. ARCHITECT MAT. MATERIAL FLOOD ZONE: Not Required @ AT MAX. MAXIMUM INSTALL MISSED LOCKS OR OTHER HW,ADD WEATHER STRIP,AND MAKE THEM OPERABLE. 21. COPYRIGHT©2023, STUDIO A/B ARCHITECTS SOME OF WINDOWS SHOULD BE REPLACED, INCLUDING SINGLE PANE WINDOWS WITH INSULATED THE ARCHITECTURAL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STUDIO A/B ARCHITECTS BLD'G BUILDING MECH. MECHANICAL PANE WINDOWS. BUT THAT IS NOT IN THIS SCOPE. AND WERE PREPARED AS AN INSTRUMENT OF SERVICE TO THE OWNER AT HIS/HER REQUEST. THEY B.O. BOTTOM OF MEMB. MEMBRANE 3.2 FLOOR STRUCTURE REINFORCEMENT, WHERE NEEDED. MAY NOT BE DUPLICATED OR USED IN PART OR IN WHOLE FOR ANY OTHER LOCATION, PURPOSE, C.I. CAST IRON MIN. MINIMUM PROJECT OR OWNER WITHOUT THE EXPRESS, WRITTEN CONSENT OF STUDIO A/B ARCHITECTS. CL CENTER LINE MTD. MOUNTED 3.3 REPLACE ANY DETERIORATED EXTERIOR WOOD AND REPAINT ALL EXPOSED WOOD. CLG. CEILING MTL METAL 3.4 REMOVE CHIMNEY AND ALL RELATED REPAIRS, INCLUDING BUT NOT LIMITED TO ROOF, FASCIA, LOCATI OfW MAP: CLG. CLOSET N.I.C. NOT IN CONTRACT GUTTER, CEILINGS, WALL, AND FLOORS. 3.5 THE STAIRWAY BANISTER IS LOOSE AND SHOULD BE RESECURED TO PROVIDE SAFE USE. CMU CONCRETE MASONRY UNIT NO. NUMBER NOMINAL %COLUMN NOM. 3.6 FLOOR STRUCTURE IN BASE: THE WOOD SHIMS SHOULD BE REPLACED WITH STEEL OR SLATE SHIMS. CONTROLLED INSPECTIONS: PROJECT SITE COL. CONC. CONCRETE NTS. NOT TO SCALE ANY NOTCHED BEAMS SHOULD BE SISTERED TO PROVIDE INTENDED SUPPORT. TEMPORARY LOLLI r ' [ CONTROLLED INSPECTIONS AND TESTING AS REQUIRED BY THE DOCUMENTS, CLIENT AND THE CONT. CONTINUOUS PLY PLYWOOD .1 COLUMNS HAVE BEEN INSTALLED AND SHOULD BE PROPERLY SECURED IN PLACE. 3.7 BASEMENT STAIRS: THE STEPS ARE LOOSE AND SHOULD BE PROPERLY SECURED SOUTHOLD BUILDING DEPARTMENT .... . C.J. CONTROL JOINT O.C. ON CENTER :• (P COR. CORRIDOR R RADIUS 4� THE CONTRACTOR MUST NOTIFY THE ARCHITECT OR ENGINEER FOR CONTROLLED INSPECTIONS ATRAILING 4. ALL RELATED HVAC, PLUMBING AND ELECTRICAL WORK THE CU.FT. CUBIC FEET RAILG N�Nh 0 LEAST 72 HOURS BEFORE THE SPECIFIC WORK COMMENCES. `.:.:...; CU.YD. CUBIC YARD REINF. REINFORCING d DET DETAIL R.D. ROOF DRAIN DIA. DIAMETER READ. REQUIRED C� DIM. DIMENSION, RM ROOM THE OWNER RETAINS THE RIGHT TO INCLUDE OR REMOVE ANY ITEMS ABOVE FROM THE CONTRACT. SITE SAFETY AND PROTECTION NOTES: ,\ DIM DIMMER SF SQUARE FEET DR. DOOR SIM. SIMILAR DWG DRAWING SPEC. SPECIFICATION 1 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SITE SAFETY ISSUES, MEETING ALL "< E.J. EXPANSION JOINT S.S. STAINLESS STEEL JURISDICTIONAI_AND OSHA REQUIREMENTS. ` ELEV. ELEVATION STD. STANDARD 2. SITE SAFETY PROTECTIONS SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, EGRESS, SCAFFOLDING, ENT. ELECTRIC TBD STEEL PROJECT ri FIRE PROTECTION, TRIP HAZARDS PROTECTION, ETC. THEY SHOULD ADDRESS ANY POTENTIAL ` "" � � ENT. ENTRY BD TO BE DETERMINED Fisher Residence INTERACTION BETWEEN THE EXISTING USE, GENERAL PUBLIC AND EXPOSURE TO THE CONSTRUCTION EQ. EQUAL T ,H�� EQUIP. EQUIPMENT TH.H. THICKNESS TELEPHONE PROCESS. ERV ENERGY RECOVERY VENTIL TON T.O. TOP OF EXIST. EXISTING TYP. TYPICAL ' EXT. EXTERIOR U.O.N. UNLESS OTHERWISE NOTED OPTIONS AND ALTERNATIVES FF FINISHED FLOOR V.I.F. VERIFY IN FIELD � .. FIN. FINISH OR FINISHED W WIDTH THE FOLLOWING ARE OPTIONAL AND ALTERNATIVE BID ITEMS. PLEASE PROVIDE SEPARATE ESTIMATES ^: FL. FLOOR W/ WITH ADDING OR SUBTRACTING FROM THE BID PRICE FOR EACH ITEM. THE OWNER WILL DECIDE FINAL FLASH'G FLASHING WD WOOD TITLE SHEET INCLUSION OR NOT IN CONTRACT. F.P. FIRE PROOFING W.R.B. WATER RESISTIVE BARRIER FT FEET WWF WELDED WIRE FABRIC OPT. 1 FLOOR GIRDER REINFORCEMENT ON THE SECOND FLOOR IN THE MIDDLE OF DINING ROOM. t GA GAUGE THIS GIRDER WOULD NOT BE EXPOSED UNLESS THE OWNER DECIDED TO DO SO. ALTHOUGH EXISTING °' GALV. GALVANIZED WITHOUT SHOWING GIRDER FORM ON THE CEILING, THE ARCHITECT'S CALCULATION SHOW A HUGE _ G.C. GENERAL CONTRACTOR GIRDER SHOULD BE THERE DUE TO SUPPORTING ROOF AND FLOOR LOADS. IF OWNER DECIDED TO DO GL. GLASS THIS WORK, FIRST, CONTRACTOR SHALL EXAMINE THE EXISTING STRUCTURE, AND SECOND, INSTALL GWB GYPSUM WALL BOARD NECESSARY REINFORCEMENT. H OR HT HEIGHT H.P. HIGH POINT OPT. 2 REPLACING THE FLAT ROOF COVER MATERIAL HRDWD HARDWOOD Project number 22014 HRV HEAT RECOVERY VENTILATION Date 3/13/2023 HVAC HEATING VENTILATING AND AIR CONDITIONING Drawn by HA Q ALT. 1 INSTALL BATT INSULATION ON ATTIC FLOOR, INSTEAD OF INSTALLING CLOSED CELL SPRAY FOAM HORZ. HORIZONTAL t­ Checked by GB N INSULATION ON EXISTING RAFTERS IN THE ATTIC. SEE INSULATION SCHEDULE AND A.06. M T . 01 N co Scale As indicated Cl) studio a/b architects 651 West Main Street, Riverhead, NY 11901 631 591 2402 631 3231426 X2 X5 glynis@studioabarchitects.com mailing address: REMOVE DOOR PO Box 444, Orient, NY 11957 X1 TO BE RELOCATED client: .............. Ronald A. Fisher site address: ................ ......... CLOSET PARTITION 7130 Main Road, East Marion, NY 11939 a ----Up— TO BE DEMOLISHED.................- .................... .... tel: 914 714 4859 T email: ronfis@aol.com yo VANITY CABINET REMOVED ........... ......==— tax map#: 1000-3l.-6-6 ................. . ........... ........... . ..... ..... ALL PLUMBING FIXTURES q -.,= TO BE REMOVED ...... ....... ....................... ... ............ ..........- ................ .......... . . ......................... SHOWER RECEPTOR, .................... MAIN ROAD ....... PARTITION TO BE .......... DEMOLISHED N. UTILITY POLE OH---' j. O OH H 98.26' MONUMEN N 56o 13' 50" E i t.........I TFOUND WELLS MONUMENT HEA6 FOUND DASH LINED PARTITION w TO BE DEMOLISHED, TYP. 34' N LU LLI EV. 148.61' 0 o) Uj z ............ 0 0 CHIMNEY TO BE DEMOLISHED UP 0� 48,57' 31.6 00 U P Uj 4.1' N 4�01 NNo. Description Date SEPTIC SYSTEM D\A/ORY APPROX. LOCATION OF A, A/C Uj EXISTING 1000 GAL �D 2-STORY UNIT T NELLING 6. —j NO,7130 2,20' I FF ELEV, $5.77'+/- WASTE OUTLET t. IN BASEMENT INV. ELEV. GRAVEL w I - b 32.85' +/- LO 7.70' 05 X4 10 D GENERATOR X C/r. .......... 14.6' QAVER D11L Q rjRr��i,: I Second Floor Demolition Plan 0 w z M LL LLI 0 GARDEN MASONR 0 0 UP 12,?' O C) cV V- o LO >- C(\oJ I X2 X5 1.1, D;4 1.2 IL— P.- f j 1 j I i I Ti i T,if i f it T-1 I 2080, DASH LINED WALL TO BE DEMOLISHED, X1 TYP. + it IN I y — � N 59'49' 00" E n UP I 16.82' FUTURE POOL 20'X 50' +/- Y5 II MONUMENT EV.33' MONUMENT FOUND FOUND CUT TO INSTALL DOOR WIREFENCE Y4 REMOVE DOOR TO BE WALLED GATE it L6 Q1 <- mv, FE 3.5W w I I REMOVE SHOWER RECEPTOR, PARTITION CN ALL PLUMBING FIXTURES TO BE CN 30 ­4 o REPLACED yT 0 3 7 2;" FE 4 N 0) 0 3.Ow N z 10,20' it REMOVE WALL LEAVING BOTH ENDS N; < ARDEN EXAMINE FURRED WALL DEMOLISH CHIMNEY z IF WATER PIPES ARE FOUND, 0 RELOCATE THEM IN WALL IF WASTE PIPE IS FOUND REMOVE STAIRCASE AND PARTITION WALL RELOCATE IT TO EXTERIOR WALL 0.TE AND MAKE IT POSSIBLE TO REMOVE U- FURRING PROJECT 0 I WALL 0.8'E I SITE PLAN IS BASED ON SURVEY BY BARRET BANACCI &VAN WEELE, PC t Fisher Residence DATED NOV. 14. 2022 REMOVE COUNTER CABINET q C�No EV 33' EV.33' REMOVE WINDOW FOR REPLACEMENT WINDOW TO BE REMOVED AND WALLED WELL REBAR ONUMENT FE FOUND FOUND 25W (....... .......... Site Plan Demolition ',7 F= E3 FE FE VINYL FENCE FE 0.8's 2.8'S 2.4'S Plans 0.3'E / S 59 0o 32' 30"W 116.18' IT NOTES: 1. PRIOR TO ANY DEMOLITION, EXAMINE EXISTING STRUCTURE AND INSTALL TAX LOT 5.1 NECESSARY SHORING TO SUPPORT EXISTING STRUCTURE. UP Project number 22014 X4 Date 3/13/2023 Drawn by HA ti r4 Site Plan n First Floor Demolition Plan Checked by GB lit = 201-011 1/8" = 1v-011 ce) A. 0 1 C14 I Scale As indicated 3 s.02 3 studio a/b architects REMOVE EXISTING DOOR A.03 AND WALL TO CLOSE S.02 A.03 651 West Main Street, x2 1 1 x5 DOOR TO BE RELOCATED 1 Riverhead, NY 11901 A.04 631 591 2402 631 323 1426 UP REPAIR DAMAGED RAILING 1 I nis studioabarchitects.com _...................... _. AND OTHER EXTRIOR WOOD 9 Y @ ---=__- -- WHERE NEEDED A. __....---.._........__---._..-------...._._....... EXISTING FLOOR: ."-- mailing address: PATCH FLOOR AS NEEDED WHERE i 7 j PO Box 44 Orient, Y 11957 I ! I li _r._. PARTITION IS DEMOLISHED { I I 4 O ' nt N RESAND AND REFINISHED, TYP. ! I EXISTING ROOF BELOW client: j rant(DeckRonald . I I ; � � I I � A. Fisher i I • I . � i i � I . site address. i I 7130 Main Road, East Marion, NY 11939 tel: 914 714 4859 email: ronfis@aol.com — —_ _.._-------------.- _ -- tax map#: 1000-31.-6-6 3 ; :_. ...................... . ......... ...._... . -. EXISTING ROOF BELOW ----— . ` UP �:____ . UP........ ......... . ... ...... .............. .. .. .......... _ ..... i r — .............. .... ...... ��_ _-___ _ uP ------ — P eX/S /� .. - . Y5 Den -------------Master.— .........................--. —— :- ..: _^ -:. .. Y5 ...Bedroom ..... .................... ...... uest..Room "�. ' _.._ � . _ ................. LivingRoom —. ......... —.....—..-....._.. ....................._..... . .. .............. .................... --- - 1 iDOOR — — — EXISTING TO BR REMOVED AND WALLED -- ................. ....................................................._.......-.:-...-...... -.. .........__................ . --- ............_......... _ .................. ............... _._.... . ............._ A.07 _ -.._ __._-- OPEN SHELF 1 _ — � _ T 3 _ : Whroom ...:-:::::::::.::.:- :...:::-::.:..... . ... .-..... .. :...... ° T _ PIPE SPACE COVERED WITHIN BUILT IN ........... I .................... 5 I x1 I I -- ........._.................._...... I OPEN SHELF ......... I - I Bathroom 2 10 r Y . Ii - - --- - Dinin \/ ' ._ 9 -- L. EXISTING DUCT SPACE _.......... _........._......................... 2 .......:... Y3 --�� ` INo. Description Date - - - - - - - - - ---- — — TUB SHOWER NEW TILED SHOWER FLOOR — — " — — CLOTHES 7 WASHER& I A.07 X2 Study , ; x5 DRYER 1 i EXISTING CHIMNEY AND 11 A.08 � - -- - ' — - - , �- PARTIAL PARTITION I TO BE REMOVED I -- EXISTING CHIMNEY AND STAICASE TO BE REMOVED AND PATCHED EXAMINE FURRED WALL -- I Kitchen . -..T IF WATER PIPES ARE FOUND, , A.03 2 RELOCATE THEM IN WALL A.03 2 I i i 5 A.03 IF WASTE PIPE IS FOUND ' RELOCATE IT TO EXTERIOR WALL AND MAKE IT POSSIBLE TO REMOVE FURRING J ,� I i nG�� h DW I I I REPLACED WINDOW 00 WITH SHORTER ONE TO FIT CONTINUOUS KITCHEN COUNTER ! �U � I I : I : I I I EXISTING ROOF BELOW I I up� REMOVE WINDOW AND WALL I I I I II I 2 8� i I Rear:sec k p 37 QFt� `� I REPAIR DAMAGED RAILING C. ! AND OTHER EXTRIOR WOOD I WHERE NEEDED : : ..._............._.........._. ......_......_......... - INSTALL CODE COMPLYING HAND RAIL ............__...._........ ---- - ..............._......... .....__........ _.._.._ _... -- PROJECT x x4 x3 x4 Fisher Residence 4 4 i i A.03 A.03 Floor Plans EXISTING FRAMED SHED I i i Project number 22014 Date 3/13/2023 Drawn by HA 00 Checked by GB 'N 1 First Floor 2 Second Floor M N A. 02 co Scale 1/4" = 1'-0" co studio a/b architects 651 West Main Street, Riverhead, NY 11901 631 591 2402 1 A.04 631 3231426 glynis@studioabarchitects.com X5 ( X4 X3 X2 X1 Y6 Y5 Y4 Y3 Y2 Y1 mailing address: EXISTING PO Box 444, Orient, NY 11957 FASCIA, TRIM, WINDOW AND DOOR REMOVE CHIMNEY client: PATCH ROOF, FASCIA, I I Ronald A. Fisher EXISTING ROOF REPAIR AS REQUIRED GIRDER AND WALL, AS REPAINT,TYP. REQUIRED site address: 7130 Main Road, East Marion, NY 11939 tel: 914 714 4859 A�Z,� k< EXISTING FASCIA, TRIM, I I EXISTING ROOF—� I email: ronfis@aol.com WINDOW AND DOOR REPAIR AS REQUIRED tax map#: 1000-31.-6-6 REPAINT, TYP. EXISTING WALL, I REPAIR AS REQUIRED REPAINT, TYP. - (� REPLACED WINDOW EXISTING WALL, REPAIR AS REQUIRED REPAINT, TYP. _ 0 EXISTING FASCIA 0 Q N i z I Second Floor 45' - 3 1/4" Cn Cn X W REPAIR WHERE REPAIR DAMAGES CANWHERE CAN BE S WHERE DAMAGES BE SEEN I I REPAIR INSTALL HANDRAIL DAMAGES CAN — — — BE SEEN r i I First Floor 35' - 9 1/4" FT No. Description Date NO WORK ON THIS ELEVATION EXCEPT AS NOTED. EXISTING BASEMENT ENTRY North Elevation n West Elevation ` 1/4" = 1'-0" 1 A.04 REMOVE CHIMNEY EXISTING FASCIA, X1 X2 X3 X4 X5 Y1 Y2 PATCH RA OF, FASCALL, AS Y3 AND ooR OW Y4 Y5 Y6 GIRDEREQUIRED REPAIR AS REQUIRED REPAINT, TYP. I I I I I I I I I I EXISTING ROOF REMOVE CHIMNEY PATCH ROOF, FASCIA, GIRDER AND WALL, AS REQUIRED I I I I I EXISTING ROOF i EXISTING WALL, i REPAIR AS REQUIRED REPAINT, TYP. I I I I I I I I EXISTING FASCIA, WALL, TRIM, DOOR WINDOW AND I �,�` !✓F.1',AIT REPAIR AS REQUIRED - __ REPAINT, TYP. ,_ (P �237a� Q� Second FloO — EXISTING ROOF 45' - 31/4" WINDOW REMOVED, WALL PATCHED REPAIR REPAIR WHERE WHERE DAMAGES REPAIR DAMAGES ARE CAN BE SEEN WHERE I FOUND PROJECT DAMAGES ARE FOUND Fisher Residence — First Floor _ — 35' - 9 1/4" IIIHI Phil evations INSTALL CODE COMPLYING HAND RAIL I I I I I 4 South Elevation 5 East Elevation Project number 22014 Date 3/13/2023 Drawn by HA co Checked by GB M NO EXTERIOR WORK EXCEPT AS NOTED ON THIS SHEET r AND SCOPE OF WORK ON T01 SHEET. co A. 03 N co Scale 1/4" = 1'-0" Cl) studio a/b architects 651 West Main Street, Riverhead, NY 11901 631 591 2402 631 3231426 glynis@studioabarchitects.com mailing address: Y6 Y4 Y3 Y2 Y1 PO Box 444, Orient, NY 11957 client: Ronald A. Fisher site address: I I I 7130 Main Road, East Marion, NY 11939 tel: 914 714 4859 email: ronfis@aol.com tax map#: 1000-31.-6-6 I I I I 9, Existing Attic EXISTING ROOF I I INSTALL 6" R38 CLOSED CELL SPRAY FOAM INSULATION I EXISTING WALL AI_T 1: TO REMAIN UNTOUCHED INSTALL 5 1/2" R23 MINERAL WOOL BATT INSULA ION I I I I I —4- EXISTING 2x6 CEILING/FLOOR NEW PARTITION EXISTING WALL, TYP. Hallway StUdy No. Description Date ti ASSUMED JOIST 3"1 121, II 'iA DIRECTION Second Floor �V I OPTION 1. ASSUMED EXISTING 2x10 FLOOR I EXAMINE EXISTING EXISTING CEILING JOIST FLOOR GIRDER DIRECTION AND REINFORCE IF REQUIRED NEW FLOOR GIRDER i NEW CABINETS Living Room Dining I Kitchen I 0 0 0 I I I I I EXISTING 2x10 FLOOR NEW ISLAND CABINETS I I I I I First Floor 35' - 9 1/4" AF��i (P % INSTALL 5 1/2" R23 MINERAL WOOL BATT INSULATION Ofi NC\ra I I I I I rh CRAWL SPACE — — — — — — — — — — — — — — — — — — — � PROJECT 30' -- 11 1/4" Fisher Residence I I I rh Basement _ _ _ _ _ _ _ _ _ 777 _ 28' - 6" I I I I I Building Section Project number 22014 Date 3/13/2023 Drawn by HA rn n Typical N-S Section 1/2" = 1'-0" pecked by GB N v A. 04 N co T Scale 1/2" = 1'-0" M Paint Types Insulation Schedule studio a/b architects Paint Product insulation# Construction Material Thickness, R value Note 651 West Main Street,Type Application Hue 1st Coat Fnish Coat Color Riverhead, NY 11901 1 Roof over attic(btwn Y3-Y6) Closed Cell Spray Foam Insulation between rafters 6", R 38 Cavity between 2x6 rafters; No Roof vent required 631 5912402 1 or 2 coats Benjamin Moore Re al@ Select Premium Interior Paint& 1 Alt. Roof/Ceiling btwn Y3-Y6 Mineral Wool Batt Insulation between ceiling Joists 5 1/2"R 23 Replacing existing, if existing, and if R value is less 631 3231426 A Interior Gypsum Wallboard Latex Flat 1 9 9 ( ) 9 Primer, Flat(547). Spot prime as needed for the repaint. 2 Exterior Walls Mineral Wool Batt Insulation between studs,where studs are exposed 3 1/2" R15,or more if fit in glynis@studioabarchitects.com B Interior Gypsum Wallboard in Wet Location Latex Matte 2 coats Benjamin Moore Aura Bath&Spa Waterborne Interior Paint- exposed space Matte(532) 3 Floor above unconditioned space Mineral Wool Batt Insulation between Joists 5 1/2", R23 mailing address: C Interior Wood Painted Latex Semi-Gloss Benjamin Moore Fresh Start@ Multi-Purpose Latex Primer(N023)or Fresh 1 or 2 coats Regal@ Select Premium Interior Paint& Primer, Semi-Gloss 4 Shim space around window and door,where Fill all along the shim space with flexible spray foam insulation PO Box 444, Orient, NY 11957 Start@ High-Hiding All Purpose Primer(K046) (551) exposed Finish: 1 or 2 coats Regal@ Select Premium Interior Paint& Primer, 5 Construction joints, where accessible Fill all along the connection joints with flexible spray foam insulation Semi-Gloss(K551) client: D Interior Wood Clear Finish Water Base Polyurethane, Low Lustre 2 or 3 coats Benjamine Moore Stays Clear@ Acrylic Polyurethane 423 E Exterior and Interior Wood Stained, UV Bio-Based Stain Ecoprocote TimberSoy by Eco Safety Products 1 coat Ecoprocote AcriSoy(no sheen), or Eco-Tuff High Traffic Clear Coat Ronald A. Fisher protective (www.ecosafetyproducts.com, 877 366 7547) (gloss) by Eco Safety Products(www.ecosafetyproducts.com, 877 366 7547) site address: F Exterior Wood Painted Latex Low Lustre 2 coats Benjamin Moore Regal@ Select Exterior Paint High Build Low Residential Equipment Schedule 7130 Main Road, East Marion, NY 11939 Lustre Finish (401) 4859 G Exterior Wood Deck Stain Translucent Stain Cabot Wood Toned Deck& Siding Stain, or eq. # Equipment Type Product Notes to: 714 email:l: ronfis@aolaol.com H Exterior Wood Deck Sealer Clear Sealer 1 coat Cabot@ Crystal Clear Waterproofing#1000 1 Dish Washer Owner supplied tax map 1000-31.-6-6 2 Refrigerator Reuse existing Owner supplied 3 Stove Owner supplied Tile Types 4 Clothes Washer Owner supplied 5 Clothes Dryer Owner supplied Tile# Tile Type Application the Tile Product the color the texture 6 Rangehood sizeand CFM to match the stove Owner supplied 7 Bathroom Exhaust fan Panasonic FV-0511VF1, or eq. 1 each in Bathroom 1,2 &3 A Wall 4"x 12"Subway Tile Bathroom wall Daltile Vitruvian glazed ceramic, or eq. Owner selects glossy 8 Geiling Paddle Fan Owner supplied B1 1"xl" Porcerain Mosaic Tiles Bathroom floor in Bathroom 1 and 3 Daltile Keystones, or eq. Owner selects Brownberry matte B2 12"x24" Porcelain Slab tile Bathroom floor in Bathroom 2 Daltile Unity- 12"x 24" Rectangle Wall &Floor Tile-Textured Tile Visual Coffee P404 textured Model:P4041224S1T,or eq. Owner selects Room Finish Schedule Bathroom Accessory Schedule Finish Numtber Fixture dim. Product Quantity Finish Note Room# Room Name Floor Base 7 Trim Wall Ceiling Comments 1-1 Shower Enclosure 73-3/8" High x 34-1/8"Wide x Vigo Monteray 73-3/8" High x 34-1/8"Wide x 34-1/8" Deep Hinged 1 in Bathroom 1 Clear/Chrome build.com, Owner selects 34-1/8" Deep Frameless Shower Enclosure with Clear Glass, 1 Living Room Existing HW flooring, patch Existing, patch as needed Existing, patch as needed, repainted (Type C) Existing GWB, patch as needed, repainted (Type A) Existing GWB, patch as needed, Model:VG6011 CHCL363, or eq. as needed repainted (Type A) 1-2 Shower Screen 73-3/4" High x 33-3/4"Wide Zenith Shower Screen Frameless Shower Door with Clear Glass, 1 in Bathroom 2 Clear/Chrome build.com, Owner selects 2 Dining Existing HW flooring, patch Existing, patch as needed Existing, patch as needed, repainted (Type C) Existing GWB, patch as needed, repainted(Type A) Existing GWB, patch as needed, Mode I:VG6075STCL3474, or eq as needed repainted (Type A) 1-3 Tub Screen 57-3/8" High x 34"Wide Vigo Rialto Hinged Frameless Tub Door with Clear Glass, 1 in Bathroom 3 Clear/Chrome build.com, Owner selects 3 Kitchen Existing HW flooring, patch Existing, patch as needed Existing, patch as needed, repainted (Type C) Existing GWB, patch as needed, repainted (Type B) Existing GWB, patch as needed, Model:VG6074CHCL3458, or eq. as needed repainted (Type A) 2-1 Shower Pan for Tiling 36"x 36" Tile Redi Redi Base@ Left Double Curb Shower Pan With Center 1 in Bathroom 1 https:/Iwww.tileredi.com/ 4 Den Existing HW flooring, patch Existing, patch as needed Existing, patch as needed, repainted (Type C) Existing GWB, patch as needed, repainted (Type A) Existing GWB, patch as needed, Drain, 36"D x 36"W, 3636CDL-PVC, or eq. as needed repainted (Type A) 2-2 Shower Pan for Tiling 30"D x 60"W Tile Redi Redi Base@ Single Curb Shower Pan With Center Drain, 1 in Bathroom 2 https://www.tileredi.com/ 5 Bathroom 1 Porcerain Mosaic Tile(Type lx4 painted (Type C) Existing and/or New lx4 painted (Type C) Subway tile (Type A), partially WRGWB painted Repaint(Type B) 30"D x 60"W, 3060C-PVC, or eq. B1) (Type B) 3-1 Surface mount Medicine 24"X 30" Kohler Verdera K-99006NA with Mirror side panel, or eq. 2 in Bathroom 1 build.com, Owner selects 6 Master Existing HW flooring, patch Existing, patch as needed Existing and/or New lx4 painted (Type C) Existing GWB, patch as needed, repainted (Type A) Existing GWB, patch as needed, cabinet and 3 Bedroom as needed repainted (Type A) 3-2 Wall recessed mount Medicine 24"X 30" Kohler Verdera K-99006NA, or eq. 1 in Bathroom 2 build.com, Owner selects No. Description Date 7 Hallway Existing HW flooring, patch Existing, patch as needed Existing and/or New lx4 painted (Type C) Existing GWB, patch as needed, repainted(Type A) Existing GWB, patch as needed, cabinet as needed repainted (Type A) 4 Vanity wall mount Cabinet 60"Wide Fresca Lucera 60"Wall Mounted Single Basin Vanity Set with Cabinet 1 in Bathroom 2 Espresso build.com;Vanity sink integrated, 8 Guest Room Existing HW flooring, patch Existing, patch as needed Existing and/or New lx4 painted (Type C) Existing GWB, patch as needed, repainted (Type A) Existing GWB, patch as needed, and Quartz Vanity Top, Model:FCB6160ES-UNS-CWH-U, or eq. Owner selects as needed repainted (Type A) 5 Shelf w/Towel Bar 18" Moen CS15207-181 CH,or eq. 3 total, 1 in each Chrome build.com, Owner selects 9 Bathroom 2 Porcerain slab Tile (Type B2) lx4 painted (Type C) Existing and/or New lx4 painted (Type C) Subway tile (Type A), partially WRGWB painted Repaint(Type B) Bathroom (Type B) 6-1 Towel Bar 18" Gatco Glam 18"Towel Bar#4631 or eq, 1 in Bathroom 1 Chrome build.com, Owner selects 10 Bathroom 3 Porcerain Mosaic Tile(Type lx4 painted (Type C) Existing and/or New lx4 painted (Type C) Subway tile(Type A), partially WRGWB painted Repaint(Type B) 6-2 Towel Bar 24" Gatco Glam 24" Double Towel Bar 4644, or eq. 1 in Bathroom 2 Chrome build.com, Owner selects B1) (Type B) 7-1 Glab Bar 18" Moen 8700 (8718PS), or eq. 1 in Bathroom 1 SS build.com, Owner selects 11 Study Existing HW flooring, patch Existing, patch as needed Existing and/or New lx4 painted(Type C) Existing GWB, patch as needed, repainted(Type A) Existing GWB, patch as needed, repainted (Type A 7-2 Glab Bar 24" Moen 8700 (8724PS), or eq. 2 total, 1 each in SS build.com, Owner selects as needed P ( yp ) �- Bathroom 2&3 FINISH NOTES: 8 Toilet Tissue Holder American Standard Studio S Model:7105230.002, or eq. 3 total, 1 in each Chrome build.com, Owner selects 1. ALL NEW INTERIOR WALL AND CEILING FINISHES SHALL HAVE A FLAME-SPREAD CLASSIFICATION OF NOT GREATER _ Bathroom THAN 200, SMOKE-DEVELOPED INDEX OF NOT GREATER THAN 450, AS PER SECTION R315 (NYS RESIDENTIAL CODE). r9 Shower Basket 11" Ginger Splashables Combination Basket 501/PC,or eq. 3 total, 1 in each Polished Chrome build.com, Owner selects 2. IF REQUIRED, PROVIDE FINISH SAMPLES ON THE SPECIFIED MATERIALS. Bathroom 3. SEE BUILT-IN SCHEDULE, AND A.08, 09 FOR FINISHES OF BUILT-IN CABINETS 10 Robe Hook American Standard Studio S 7105210, or eq. 3 Chrome build.com, Owner selects 4. EXISTING PATCH WORK MIGHT REQUIRE DIFFERENT PAINTS OR STAINS TO MATCH EXISTING. CONTRACTOR SHALL PROPOSE THESE COATINGS/STAINS. Door Schedule Mark Room DcorType Dim Product Finish Frame and Trim Lock Set Handle Note 1 Bathroom 1 Reuse existing, relocated Repaint(Type C) Existing 2 Master Bedroom Reuse existing, relocated Repaint(Type C) Existing 3 Guest Room Reuse existing, relocated Repaint(Type C) Existing 4 Bathroom 2 Hinged Panel Door 30"x 80" Style to match existing Paint(Type C) Style to match existing Privacy Owner selects 5 Master Bedroom Closet Double Leaf hinged door 60"x 80" Style to match existing Paint(Type C) Style to match existing Closet Owner selects 6 Guest Room Closet Double Leaf hinged door 42"x 80" Style to match existing Paint(Type C) Style to match existing Closet Owner selects 7 Bathroom 3 Hinged Panel Door 30"x 80" Style to match existing Paint(Type C) Style to match existing Privacy Owner selects 8 Hallway Closet Double Leaf hinged door 34"x 80" Style to match existing Paint(Type C) Style to match existing Closet, or catch &pulls Owner selects 9 Laundry Closet Double Leaf hinged door 48"x 80" Style to match existing Paint(Type C) Style to match existing Closet, or catch &pulls Owner selects DOOR NOTES: 1. TYPICAL INTERIOR DOOR OPTIONS SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE: FINISH: AS PER DOOR SCHEDULE ALL HW FINISH SHALL BE SATIN NICKEL HINGES: SATIN NICKEL 2. BEFORE ANY PRODUCTION OR PURCHASE, VERIFY THESE OPTIONS WITH OWNER x ` �',�'� <378� C� j . Window Schedule Window # Product Dimentions R.O. Finish Glazing Sill Height �Head !­Ieight� Comments 1 Andersen 400 TW1836 l'-9 5/8"x 3'-8 7/8" 1'- 10 1/8"x 3'-8 7/8" Exterior white; Interior Low E4 3'-5 3/8" T-2 1/4" Replacing Existing white PROJECT 2 Andersen 400 TW2.636 2'-7 5/8"x 3'-8 7/8" 2'-8 1/8"x 3'-8 7/8" Exterior white; Interior Low E4 3'-5 3/8" T-2 1/4" Replacing Existing white Fisher Residence WINDOW NOTES: 1. ALL EXISTING WINDOWS SHALL REMAIN, EXCEPT TWO WINDOWS WEST IN THE KITCHEN TO BE REPLACED; ALSO, ONE AT THE SOUTH OF KITCHEN SHALL BE REMOVED. 2. CONTRACTOR SHALL EXAMINE ALL CONDITIONS OF WINDOWS. REPAIR AS REQUIRED. 3. ANDERSEN WINDOW OPTIONS: Schedules GLAZING: LOWE4 FINISH: WHITE ON BOTH EXTERIOR AND INTERIOR GRILL: #1: 4 OVER 4; #2: 6 OVER 6 SCREEN: TRUE SCENE HW: STONE Project number 22014 Date 3/13/2023 Drawn by HA Q M Checked by GB co �- A. 05 MNC) N M Scale 12" = 1'-0" co RIDGE VENT studio a/b architects 651 West Main Street, Riverhead, NY 11901 631 591 2402 631 3231426 glynis@studioabarchitects.com mailing address: ROOFING ROOFING PO Box 444, Orient, NY 11957 ASPHALT FELT /-/ P�F'' ASPHALT FELT /- / INSULATION BAFFLE / client: SELF ADHERED WATERPROOF MEMB. /// SELF ADHERED WATERPROOF MEMB. Ronald A. Fisher site address: SHEATHING VENTED ATTIC SHEATHING / 7130 Main Road, East Marion, NY 11939 j/ / tel: 914 714 4859 email: ronfis@aol.com EXPANDING' / / ATTIC INSULATION FILL ALL JOINTS WITH FOAM INSULATION /'/ tax map#: 1000-31.-6-6 FOAM SEALANT CLOSED CELL SPRAY FOAM /" ROOF INSULATION -- - ----- ----- /" - - - - - - 3/4" RIGID INSULATION 3/4' RIGID INSULATION //' i UN VENTED ATTIC REMOVE EXISTING INSULATION, ASSUMED LOOSE FILL, IF THERE IS. METAL DRIP /"/ METAL DRIP CONTINUOUS L CEILING FINISH CONTINUOUS L CEILING FINISH BEAD OF TAPE OR SEAL BEAD OF TAPE OR SEAL SEALANT, IF ALL JOINTS SEALANT ALL JOINTS APPLICABLE SOFFIT VENT i E INTERIOR FINISH i < INTERIOR FINISH EXTERIOR SIDING I CAVITY INSULATION EXTERIOR SIDING I CAVITY INSULATION INSTALL WHERE STUDS ARE WRB(SELF ADHESIVE TYPE) WRB (SELF ADHESIVE TYPE) EXPOSED. SHEATHING I SHEATHING I I EXTERIOR WALL TO ROOF CONNECTION WITH ATTIC EXTERIOR WALL TO ROOF CONNECTION WITH ATTIC WOOD FRAME No. Description Date EXTERIOR SIDING I CAVITY INSULATION CONTINUOUS RIGID INSULATION INTERIOR FINISH CONTINUOUS BEAD OF SEALANT EXPANDNING FOAM E INT. FIN. WRB (SELF CONTINUOUS BEAD OF SEALANT, TYP. SEALANT < WINDOW ADHESIVE TYPE) INTERIOR FINISH — WRB(SELF ADHESIVE TYPE) EXPANDING FLOOR FINISH F FOAR1 SEALANT EXT. SHEATHING TAPE ALL JOINTS 10 HOR. AND VERT. CAVITY SELF ADHERED MEMB. FLASHING INSULATION - 1/2" X2" BACK DAM o SELF ADHERED MEMB. FLASHING SHEATHING ! CONTINUOUS I CONTINUOUS BEAD OF SEALANT BEAD OF SEALANT K SELF,-0HERED WRB (SELF ADHESIVE TYPE) MEMB. FLASHING EXPANDING FOAM SEALANT SELF-ADHERED MEMB. i WRB (SELF ADHESIVE — METAL CAP FLASHING FLASHING TYPE) SELF ADHERED MEMB. E INTERIOR FINISH WINDOW CAVITY INSULATION FLASHING SIDING SILL SEALANT d e WINDOW CONTINUOUS BEAD OF SEALANT TYPICAL WINDOW JAMB TYPICAL WINDOW SILL TYPICAL WINDOW HEAD TERMITE SHIELD STUCCO PARGE FOUNDATION TO WALL CONNECTION THERMAL PROTECTION NOTES: ENVELOP: Plan Review 1. [103.1 103.2]Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. • This project does not expose cavities of cathedral ceilingand walls. NYS EnergyConservation Code R503.1 ExceptionQ • This alteration does not use more energythan the exist ( 4 )building NYS Energy Conservation Code R503.1 -All the existing fenestrations will remain, except one window will be removed and walled. See First Floor Plan -This alteration adds roof/ceiling insulation in Attic. See Insulation Schedule N -This alteration adds floor insulation under the first floor. See Insulation Schedule J' -This alteration adds insulation or sealant to minimize infiltration. See A.06. ��� �237a7 (���• Insulation OP N � 1 [303.1]All installed insulation shall be labeled or the installed R-values provided. ' 2 [303.2,402.2.7] Floor insulation installed per manufacturer's instructions and in substantial contact with the underside of the subfloor, or floor framing C% - cavity insulation is in contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 3 [303.2] Wall insulation is installed per manufacturer's instructions. (Only where one window shall be removed and walled.) 4 [303.1.1.1,303.2] Ceiling insulation installed per manufacturer's instructions. 5 [402.2.3]Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. 6 [402.2.4]Attic access hatch and door insulation >_R-value of the adjacent assembly. IC RATED RECESSED LIGHTING PROJECT HOUSING WRAP WITH SPRAY FOAM INSULATION Air Leakage 1 [402.4.5] IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate:52.0 cfm leakage at 75 Pa. Fisher Residence 2 [403.6]Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. SYSTEMS: Plan Review 1 [103.1, 103.2,403.7] Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. • All new lighting fixture shall be LED lighting • This alteration does not change the existing mechanical system. Systems Typical Thermal CAVITY INSULATION 1 [403.4] HVAC piping conveying fluids above 105 IF or chilled fluids below 55 OF are insulated to zR-3. 2 [403.4.11 Protection of insulation on HVAC piping. INTERIOR FINISH Existing piping shall be insulated, if not insulated. Protection Details 3 [403.5.3] Hot water pipes are insulated to>_R-3. EXPANDING FOAM SEALANT Ducts 1 [403.3.1] Supply and return ducts in attics insulated >= R-8 where duct is>= 3 inches in diameter and>= R-6 where< 3 inches. Supply and return CONTINUOUS BEAD 0 SEALANT TYPICAL ELECTRICAL BOX ON EXTERIOR WALL ducts in other portions of the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. CEILING RECESSED LIGHTING Existing ducts shall be insulated, if not insulated. Lightinq Project number 22014 1 [404.1] 75%of lamps in permanent fixtures or 75%of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Date 3/13/2023 Drawn by HA M Checked by GB Cq 1 Thermal Protection Details ■ ®6 N 0 M Scale As indicated co x4 24"X 30"WALL MOUNT MEDICINE WALL TILE studio a/b architects CABINET Y^ WALL TILE SHOWER ENCLOSURE EXISTING DUCT SPACE REPLACED SINK `t • LIGHTING FIXTURE X4 CLEAR TEMPERED GLASS Y4 Y4 651 West Main Street, Riverhead, NY 11901 Y4 - - - - 6315912402 631 323 1426 24"TOWEL glynis@studioabarchitects.com NEW DOOR GWB RACK PAINTED W/BAR mailing address: PO Box 444, Orient, NY 11957 o -------- \`\ GWB GWB \\ PAINTED EQ. EQ. \\\ PAINTED I client: 2 Ro nald A. Fisher REMOVE I I \\ I \�\ \ / O N I DOOR 6 5 A. 3 SEE G#6 18 TOWEL A.07 \ / BAR site address: AND WALL \\ `\ SHOWER 7130 Main Road, East Marion, NY 11939 tel: 914 714 4859 PATCHED 4 ---� \ TOILET ISSUE \ BASKET I email: ronfis@aoLcom REPLACED --- \ � � � 2'-0" TOILET o + a, I - � o tax map#: 1000-31.-6-6 —_ � - 7" ,' 24" GRAB 0 i ¢ / BAR o / ro - - 1X4 r> PAINTED First loor - I 35' - 9' 1/4" � L � L FLOOR TILE ON EQ. EQ. 1X4 BASE PAINTED TILE ON SHOWER PAN:TILE REDI REDI BASE® NEW 36"X 36"TILED WALL TILE SHOWER PAN TILE ON SHOWER PAN LEFT DOUBLE CURB SHOWER PAN WITH ENTER v4 SHOWER PAN X5 DRAIN, 36"D X 36"W, 3636CDL-PVC, OR EQ. Bathroom 1 North Elevation n Bathroom 1 East Elevation 4 Bathroom 1 South Elevation n Bathroom 1 West Elevation 1 n Bathroom 1 West Elevation 2 1/2" = 1'-0" 1/2" = 1'-0" 1/2" = 1'-011 1/2" = 1'-0" 1 First Floor,; Callout at Bathroom 1 24"X 30"WALL MOUNT MEDICINE 1/2 - 1 -0 Y3 WALL TILE WR GWB Y4 Y4 CABINET PAINTED WALL TILE WR GWB PAINTED LIGHTING FIXTURE WR GWB PAINTED I SHELF& WALL TOWEL BAR TILE SHOWER ,/ I 24" BASKET ' DOUBLE TOWEL No. Description Date BAR \\ I o Q 36" GRAB BAR \ I (70 \ I M \ 7�, N \ 1X4 PAINTED Second Floor '1145' 3 1/4" �- 1X4 PAINTEDL 1X4 PAINTEDL 60"WIDE WALL MOUNT VANITY CABINET FLOOR TILE ON SHOWER PAN n Bathroom 2 West Elevation Bathroom 2 North Elevation Bathroom 2 East Elevation n Bathroom 2 South Elevation 1/2" = 1'-0" if GWB PAINTED 1 -7 LIGHTING 24"X 30"WALL FIXTURE MOUNT MEDICINE - - CABINET EQ EQ. SHELF& \ ! TOWEL BAR I \ `\ MOVABLE \ SHELF ! `\ 3/4" MDF \ STAIN/SEALED I -. .. - - — -A.04 - - ..Master Bedroom _ _._ _--_-.___--..--_.____--- _- --_ _-_- -- Guest-Room ..... . . . ........ ..... . - } , 0' 4 1/2" rh IO ,�>„Y Second or .... b - - _�_- �___ _— -------___ .__..._ I 45 - 3 1/4 x4 B PAINTED, R� 0�s7a�............................. .. ...... . ........._........... ........................................ 1 BASE PAIN P. Y4 — — _ „ T Bathroom 3 West Elevation Bathroom 3 North Elevation �OF �Cy`� .... 1'-6„ ........................ . .................................... ... .. ........ SH ELF F SHELF: 3/4"MDF SEALED/STAINED - - - r� 0 -4 R GWB PAINTEDWALL TILEWALL 5'-6" 5'- 11"+/- 0'-4 1/2" .. ....... 3'-4 1/2" ...... ... ..... N I TILE 10 Hallwayi o o ......- -..- T.------- � I PROJECT _ _ � Fisher Residence Bat oom 3 13 is er 0'-4 1/2" ......................... .................................. 3,-0„ 10 A.12 14 SHELF - - -.-._- .--------- ' INTERIOR ... ... ..... ..... ............. - I GWB 9 ................................ ............._ 15 _ _ PAINTED Bathroom 2 8 A.07 10 - - ------- -- _ o ......... .. . 11 _ I . .........g...... -. . .— -.-..._.... ....- .............._......_..........._.......... ............... -- -- - -- - SHOWER BASKET Bath room Details __. - -------- ---- - ---- -- - MOVABLE ... ............. .. o SHELF 8...... ... _ -- 3/4" MDF - - - ------ - STAIN/SEALED ...................... . ...... .................................. ............................ 36"GR BAR . ........ .. .. ........ .. ....... — A Q - - SHOWER - - - - - - - - - Cl) Project number 22014 3'- 10 3/4"+/- 1 N Date 3/13/2023 TILED SHOWER PAN FRAMELESS GLASS �f SCREEN Second Floor Drawn by HA Q X2 X3 (�J4 X5 45' - 3 1/4" Checked by GB M 1X4 PAINTED, TYP. REPLACED TUB SCREEN M 7 Second Floor - Callout 1 Bathroom 3 East Elevation Bathroom 3 South Elevation A. 07 o 1/2" = 1'-0" 14 1/2" = 1'-0" 1/2" = 1'-0" M Scale 1/2" = 1'-0" Cl) X3 Ao$ X2 Y3 studio a/b architects HEAD FILL BOARD 651 West Main Street, PAINTED 24" Riverhead, NY 11901 631 5912402 631 3231426 + glynis@studioabarchitects.com v EXISTING WALL WIDTH 132 3/4"+/- M mailing address: 1 1/2" 1 1/2" PO Box 444, Orient, NY 11957 GWB PAINTED SIDE FILL BOARD OPEN SHELF N PAINTED A.08 SIDE BOARD client: + + PLYWD PAINTED 2 - Ronald A. Fisher 361/2" 96" M M co I PO�UN�DTERTOP 7130 Main site sRoad, East Marion, NY 11939 ADJUSTABLE SHELF Cl) PAINTED eema914on s@aol.com o I PAINTED, TYP. tax map#: 1000-31.-6-6 CV N COUNTER N U REVEAL W/FINGER CUT ON 'W. _ TOP OF DOOR, PAINTED > \ N _ \ Wof - N M \ '� \ '� \ '� Cl) ADJUSTABLE SHELF PIPE SHAFT \ \ \ X3 _ - First Floor First Floor "' 35' - 9 1/4' �i` — °'' 35' - 9 1/4" X2 I I 9,Ell 36" 132 1/2" 1/2" 1 First Floor - Callout 2 n 1 - a n W-E Section 17 thru bedrooms1 1/2" = 1'-0" " 1/2" = 1'-0" . Y1 Y2 EXAMINE FURRED WALL 7 PARTION AND CHIMNEY No. Description Date IF WATER PIPES ARE FOUND, I TO BE REMOVED FINISHED WALL REMOVE THEM IN WALL 2'-9" WALL END: GWB WRAP 2 -9„ I IF WASTE PIPE IS FOUND PAINTED _ REMOVE IT TO IN EXTERIOR ----- -_r WALL AND , MAKE IT POSSIBLE TO REMOVE FURRING I T I � HINGED LID 3/4" FIR PLYWD i --=_-' ---- I PAINTED GWB PAINTED / I 1'-9 3/4" 0'-3" PATCH FLOOR, WALL i _ REFRIGERATOR AND CEILING �� i i BACK SPLASH, TYP. i BULLNOSE i i SSTL SHEET TALL PANTRY REVAL REPLACED CABINET, TYP. i i GRIP ECUT TOP OF WINDOW i i DOOR, TYP. _ ..-- - u j I 0'-03/4" - - - - - - - - - - - - — - - 0'-0 3/4" PIANO HINGE I I I i° _ —�A — — _ _ _ _ STOVE DRAWER _ _� _ REFRIGERATOR CABINET I CABINET I ` CABINET I A.09 1 FINISHED IIE _ ,' 3 A.09 ( :---� FLOOR _ _ - - J� First Floor 35' b 3 1/2"+/- 36" 30" 30" 30" 30" 36" --------- FRONT APRON 2'-0" STOVE, 3/4" FIR PLYWD I (2)-PULL- RANGE FOOD \ , DUCT AND DW b PAINTED OUT TRAY, TYP. WEATHER CAP x 7 Misc-,Bench Detail 4 Kitchen West 11 3'-2 3/16" +/- -----3'-0"� T-0" 1 1/2" = 1 -0 1/2 — 1 -0 \ II Y2 a REPLACED n BENCH �5 �y WINDOW II SEAT: PLYWD O �pYa Ar) iC II II PAINTED / C7 tag- Q?3731 OQ� II - � N 120 II I I 2 I //, III /// \\\ I /// \\\ I I /// \\\ I I I I I I — FIXED SHELF PROJECT Fisher Residence ADJIUSTABLE ' ' \ ' ` / + SHELF,TYP. / I / \`\ / \\\ I I � \\\ I COAT HANGER ROD \ I\ TALL CABINET I\ I` COAT ABINET / 24" 24" I \ \\ TYP. 01 KITCHEN BUILT-IN NOTES' Built-in Details 1. CABINET CONSTRUCTION: PLYWOOD 2. CABINET FINISH: LACQUER PAINTED, COLOR WHITE PULL-OUT TRAY 3. DOOR STYLE: ND SLAB, OR SHAKER, OWNER SELECTS TYP' 4. HW: EUROPEAN CONCEALED HINGES, - 5. DOOR PULLS: GRIP CUT TOP OF DOOR WITH REVEAL WHERE NO REVEAL; WIRE PULL OR OWNER SELECTS \ / \ / BENCH \ / 6. COUNTERTOP: OWNER SELECTSJL — — — —\ /- - - - J L _- - -\ / - - - - J I _ First Floor S.02' WINDOW REMOVED APPLIANCES: M 35' - 9 1/41' AND WALLED REFRIGERATOR: REUSE EXISTING Project number 22014 STOVE, RANGE FOOD,AND DISH WASHER, OWNER SUPPLIED Date 3/13/2023 X3 1 X4 CLOTH WASHER AND DRYER: OWNER SUPPLIED 27 48" 48" 60" 48" J. Drawn by HA A.04 2 3/4" 1 1/2" M Checked by GB M 3 FirstM - Callout 3 5 Kitchen East A. 08 co 1/2" " 1/2" = 1'-0" N N co Scale As indicated M studio a/b architects 651 West Main Street, Riverhead, NY 11901 631 591 2402 631 3231426 glynis@studioabarchitects.com mailing address: PO Box 444, Orient, NY 11957 COUNTERTOP 10'-0" 3'-0" !�' OVERHANG FOR 10'-01, client: SEATING - Ronald A. Fisher 24 3/4" 11 1/41 site address: 7130 Main Road, East Marion, NY 11939 tel: 914 714 4859 email: ronfis@aol.com tax map#: 1000-31.-6-6 FINISHED SIDE DW / FINISHED REAR PANEL [ _ / _ ] _ � First Floor — — — 35' - 9 1/4" 15" 36" 24" 15" 15" 15" 10 SINK CABINET (1)-SHELF (2)-SHELVES (2)- PULL-OUT TRAYS, TYP. North Elevation is mirroed of this elevation 1 Kitchen Island West Elevation 2 Kitchen Island South Elevation n Kitchen Island East Elevation 1/2" = 1'-0" No. Description Date a L, cr .`fA r' yr 02 gZ PROJECT Fisher Residence Built-in Details 2 Project number 22014 Date 3/13/2023 Drawn by HA a 0 Checked by GB M A. 09 Cl) N O N co Scale 1/2" = 1'-0" M NAILING SCHEDULE GENERAL NOTES: (AS PER CODE STATE OF NEW YORK AND AMERICAN FOREST& PAPER ASSOCIATIONS WOOD FRAME CONSTRUCTION MANUAL FOR 1 &2 FAMILY DWELLINGS) AS PER AMERICAN WOOD COUNCIL'S WOOD FRAME CONSTRUCTION MANUAL FOR 1 &2 FAMILY DWELLINGS studio a/b architects THE FOLLOWING NOTES ARE TYPICAL, REFER TO ATTACHED DRAWINGS FOR APPLICATION JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING �`oo ROOF FRAMING QQO 651 West Main Street, 1. DRAWINGS ARE NOT TO BE SCALED. USE DIMENSIONS ONLY. CONTRACTOR SHALL CHECK ALL DIMENSIONS AND N/A(NOT IN SCOPE) gv QP Riverhead, NY 11901 CONDITIONS AT JOB SITE. ANY DISCREPANCIES OR OMISSIONS FROM PLANS AND/OR SPECIFICATIONS MUST BE CALLED ��O�p,'f��' 631 5912402 TO THE ATTENTION OF THE RECORD ARCHITECT AND SAME CORRECTED WITHIN (5) DAYS AFTER CONTRACT HAS BEEN 631 3231426 AWARDED. OTHERWISE CONTRACTOR WILL BE HELD RESPONSIBLE FOR SAME. �C�'OC,PL�`oG glynis@studioabarchitects.com 2. CONTRACTOR AND/OR SUBCONTRACTORS SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WALL FRAMING WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSES, DISTORTIONS AND MISALIGNMENT ACCORDING N/A(NOT IN SCOPE) �O�' �.`'e mailing address: TO ALL APPLICABLE CODES, STANDARDS, AND GOOD CONSTRUCTION PRACTICES. 025 X PO Box 444, Orient, NY 11957 3. ALL MATERIALS AND CONSTRUCTION TO BE INCORPORATED IN THE WORK SHALL BE IN STRICT ACCORDANCE WITH THE N LATEST EDITION OF A.S.T.M. SPECIFICATIONS WHERE APPLICABLE AND SHALL CONFORM TO THE STANDARDS AND FLOOR FRAMING LB c) RECOMMENDATIONS OF THE VARIOUS TRADE INSTITUTES (A.C.I., A.I.S.C., S.J.I., ETC.)ARE APPLICABLE. ALL MATERIALS JOIST TO SILL, TOP PLATE OR GIRDER (TOE-NAILED) 4-10d PER JOIST v client: USED IN CONNECTION WITH THIS PROJECT MUST BE NEW MATERIALS UNLESS OTHERWISE STATED. 0 4. ALL DIMENSIONS AND CONDITIONS TO BE VERIFIED BY CONTRACTORS PRIOR TO CONSTRUCTION AND PRIOR TO ORDERING w Z Ronald A. Fisher MATERIALS. ROOF SHEATHING Z 5. CONSTRUCTION TO CONFORM TO NYS BUILDING CODE, RESIDENTIAL CODE, ENERGY CONSERVATION CODE, FIRE CODE, Q site address: PROPERTY MAINTENANCE CODE,PLUMBING CODE, MECHANICAL CODE, FUEL GAS CODE, TOWN OF SOUHOLD CODES, AND N/A(NOT IN SCOPE) Z 7130 Main Road, East Marion, NY 11939 ALL OTHER CODES AND REGULATIONS HAVING JURISDICTION. _< w tel: 914 714 4859 6. THESE PLANS ARE DESIGNED TO MEET OR EXCEED THE REQUIREMENTS OF THE NEW YORK STATE BUILDING CODE. WHEN o Q m _ zoo email: ronfis@aol.com BUILDING IN ANY JURISDICTION, EITHER INSIDE OR OUTSIDE THE CODE, VARIATIONS MAY BE REQUIRED. IT IS THE WALL SHEATHING z X ; RESPONSIBILITY OF THE PLAN PURCHASER OR BUILDER TO VERIFY SUCH REQUIREMENTS WITH THE LOCAL CODE OR N/A(NOT IN SCOPE) LLO �T �I tax map#: 1000-31.-6-6 ENFORCEMENT OFFICER AND TO AMEND THE PROPOSED CONSTRUCTION AS SO REQUIRED. 7. CONTRACTOR SHALL LOCATE AND IDENTIFY ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. CONTACT ALL UTILITY F- v COMPANIES IF RELOCATION IS REQUIRED AND/OR REPAIRS. Uj a 8. RECORD ARCHITECT IS NOT RESPONSIBLE FOR SUPERVISION, INSPECTION, OR ADMINISTRATION OF THIS PROJECT. CEILING SHEATHING Z 9. ASSUMED SOIL TO BE SAND OR GRAVEL, WITH MINIMUM TRACES OF DRY CLAY, WITH A MINIMUM BEARING CAPACITY OF 2 N/A(NOT IN SCOPE) ,�, i o ��P�����Fz TONS/SQ. FT. 10 ALL FOOTINGS TO REST ON VIRGIN, UNDISTURBED SOIL. ` \ �0�� 11. FOUNDATIONS AND FOOTINGS SIZED FOR BEARING ON VIRGIN SOIL AT MINIMUM BEARING CAPACITY OF 2 TONS PER 3 SQUARE FOOT WITH A MINIMUM OF 3'-0"COVER. FLOOR SHEATHING �a�s '� 12. PIER FOOTINGS SHALL EXTEND 6" FROM FOUNDATION ON ALL SIDES AND SHALL BE 12"THICK. N/A(NOT IN SCOPE) 13. CONCRETE TO BE PLAIN, UNREINFORCED, MINIMUM 2500 PSI, 28 DAY SOIL TEST, PREDICATED ON THE ABOVE SOIL CONSUMPTION. IF OTHER SOILS ARE ENCOUNTERED, LOWER BEARING VALUES ARE TO BE ASSUMED AND THE FOUNDATION MUST BE REDESIGNED. INDIVIDUAL SITE CONDITIONS MAY ALSO REQUIRE SPECIAL FOUNDATION DESIGN, WHICH IS THE RESPONSIBILITY OF THE PLAN PURCHASER OR BUILDER. vQQO QP� 14. STRUCTURAL STEEL TO BE ASTM A36. DETAILED, FABRICATED AND ERECTED PER AISC. 15. ALL WOOD FRAMING, INCLUDING JOISTS, BEAMS, POSTS, STUDS, ETC.,TO BE DOUGLAS FIR LARCH NO. 2 OR BETTER, UNLESS NOTED OTHERWISE. Gp,L��oo Lumber Design Criteria WALL OPENING MEMBER SCHEDULE �O O�G�V0 Visually graded lumber ROUGH OPENING HEADER HEADER TO NUMBER OF SILL SILL TO WALL Douglas Fir Larch (#2 Surfaced Dry or Green @ 19%maximum moisture content) SPAN WALL JACK STUDS CONNECTION 0 All values and factors are from the National Design Specifications for CONNECTION Wood Construction NDS-2001. 8' >=W> 6' (2)-2X12 OR 8-16d END- (1)-2X6 (2)-2X6 (3)- 16d Extreme Fiber Stress in Bending (Fb) (2)-MICRO 13/4"X NAILED TOE-NAILED Single Members Repetitive use Factor Bending Stress 9 1/4"OR LARGER Notch and Hole on Existing Floor Beam Member Fb(psi)x Cf= Fb(psi)x Cr = Fb(psi) 6' >=W> 4' (( )- 2 2X10 OR 6-16d END- (1)-2X6 (2)-2X6 (3)- 16d 2x6 850 x 1.30= 1105 x 1.15 = 1271 2x8 850 x 1.20= 1020 x 1.15 = 1173 LARGER NAILED TOE-NAILED 2x10 850 x 1.10 = 935 x 1.15 = 1075 4' >=W (2)-2X8 OR 4-16d (1)-2X6 (2)-2X6 (2)- 16d 2x12 850 x 1.00 = 850 x 1.15 = 978 LARGER TOE-NAILED Horizontal Shear Stress = Fv x CH = 190 psi Modulus of Elasticity = 1.60E+06 psi UPLIFT CALCULATION, MONOSLOPE ROOF 12) (17.25 ft)/2 =4,4 No. Description Date Tu =Wuplift x(16/12) x L/2=36 psf x(16/ 16. ALL LAMINATED VENEER LUMBER(LVL) SHALL MEET THE AMERICAN PLYWOOD ASSOCIATION (APA) ENGINEERED WOOD INSTALL SIMPSON H1 HURRICANE TIE 12 EACH RAFTER END. SYSTEM (EWS) STANDARD PRL-501 WITH A STRESS CLASS OF 1.8E-2600F. 17. ALL PLYWOOD USED STRUCTURALLY SHALL MEET THE PERFORMANCE STANDARDS AND ALL OTHER REQUIREMENTS OF LATERAL LOAD CALCULATION, FOUNDATION HOLDOWN APPLICABLE U.S. COMMERCIAL STANDARDS FOR THE TYPE, GRADE AND SPECIES OF PLYWOOD AND SHALL BE SO HOLDOWN FORCE =VxH =6347 IDENTIFIED BY AN APPROVED TESTING AGENCY. INSTALL SIMPSON HD10A HOLDOWN AT END OF SHEAR WALL 18. ALL WALL SHEATHING SHALL BE APA RATED STRUCTURAL PANELS CONFORMING TO PRODUCT STANDARD PSI WITH A MINIMUM THICKNESS OF 15/32". THE PANELS SHALL BE APPLIED WITH THE LONG DIMENSION ACROSS THE STUDS. LATERAL LOAD CALCULATION, FLOOR TO FLOOR CONNECTION 19. ALL FLOOR AND ROOF SHEATHING SHALL BE APA RATED STRUCTURAL PANELS CONFORMING TO PRODUCT STANDARD PSI HOLDOWN FORCE =VxH= 3986 WITH A SPAN RATING CONSISTENT WITH ITS INTENDED USE AND A MINIMUM THICKNESS OF 15/32" (19/32" FOR FLOOR INSTALL SIMPSON FTA5 FLOOR TIE ANCHOR AT END OF EACH SHEATHING). SECOND FLOOR SHEARWALL. 20. (INTENTIONALLY LEFT BLANK) 21. ALL STRUCTURAL WOOD SHALL BE KEPT 2" BACK FROM CHIMNEYS. 22. JOISTS HANGERS, ETC. TO BE "SIMPSON STRONG TIE" OR APPROVED EQUAL FOR FLUSH STRUCTURAL CONNECTIONS. 23. GRADING AROUND NEW CONSTRUCTION SHALL SLOPE AWAY AND BLEND INTO EXISTING CONDITIONS. PIER FOOTINGS SHALL EXTEND 6" FROM FOUNDATION ON ALL SIDES AND SHALL BE 12"THICK. 24. ALL EXTERIOR FRAMING, AND INTERIOR FRAMING DIRECTLY CONTACT TO CONCRETE OR MASONRY, SHALL BE A-_Q WIND BORNE DEBRIS PROTECTION TREATED LUMBER. FASTENERS TO USE WITH THE TREATED LUMBER SHALL BE STAINLESS STEEL, OR OTHER APPLICABLE WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16"AND A MAXIMUM SPAN OF 8 FEET SHALL BE PER'O.ITTED, MATERIAL. PANELS TO BE PRECUT TO COVER THE GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. 25. ALL HEADERS TO BE (2) 2 X 8 UNLESS OTHERWISE STATED. 26. ALL HEADERS TO BE SUPPORTED BY DOUBLE STUDS (TYP), UNLESS OTHERWISE STATED. FASTENER SPACING 27. PROVIDE DOUBLE HEADERS AND TRIMMERS AT ALL STAIR AND FLOOR OPENINGS AND UNDER ALL POSTS AND PARTITIONS RUNNING PARALLEL TO SAME. FASTENER TYPE PANEL SPAN 4 FOOT 6 FOOT 28. BRIDGING TO BE EITHER SOLID, 1"X 3"OR 18 GA. CROSS BRIDGING, MIN 8' -0" O.C. <4 FOOT < PANEL SPAN < PANEL SPAN 29. ALL STRUCTURAL WOOD SHALL BE KEPT 2" BACK FROM CHIMNEYS. <6 FOOT < 8 FOOT 30. JOISTS HANGERS, ETC. TO BE"SIMPSON STRONG TIE"OR APPROVED EQUAL FOR FLUSH STRUCTURAL CONNECTIONS. 2 1/2"#6 WOOD SCREWS 16" 12" 9" 32. FIRE BLOCKING TO CODE R602.8. NYSBC 718.2 33. INSTALL WALL TO FLOOR AND WALL TO WALL CONNECTION STRAPPINGS ON THE EXISTING SHEATHING AT EVERY STUDS 2 1/2"#8 WOOD SCREWS 16" 16" 12" 34, INSTALL HURRICANE TIES AT EVERY RAFTERS, IF NOT EXISTING a. THIS TABLE IS BASED ON 130 MPH WIND SPEED AND A 33-FOOT MEAN ROOF HEIGHT. 35. PROVIDE COMBUSTION AIR VENTS AS PER NYS ENERGY CODES. b. FASTENERS SHALL BE INSTALLED AT OPPOSING ENDS OF THE WOOD STRUCTURAL PANEL 36. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NY BUILDING CODES, THE NY BUILDING CONSTRUCTION MANUAL, c. NAILS SHALL BE 10d COMMON OR 12d BOX NAILS AND THE NY ENERGY CONSERVATION CODE. d. WHERE SCREWS ARE ATTACHED TO MASONRY OR MASONRY/STUCCO, THEY SHALL BE ATTACHED UTILIZING 37. ALL PLUMBING FIXTURES SHALL BE INDIVIDUALLY TRAPPED AND VENTED AS REQUIRED BY NY CODE. VIBRATION-RESISTANT ANCHORS HAVING A MINIMUM ULTIMATE WITHDRAWAL CAPACITY OF 490 POUNDS. CAST IRON PIPE SHALL CONFORM WITH LOCAL CODE REQUIREMENTS WITH APPROVAL JOINTS, PIPE SUPPORTS AND e. WHERE MULTIPLE PANELS ARE NEEDED, USE 2X4 ALONG THE PANEL JOINT CLEANOUTS. 38. HEATING AND COOLING DESIGNS SHALL COMPLY WITH ASHRAE STANDARDS. 39. THE GENERAL CONTRACTOR/BUILDER SHALL MAKE ARRANGEMENTS WITH THE OWNER TO SELECT, PROVIDE AND INSTALL AS REQUIRED(PER N.E.C, N.E.M.A, NAT. PLUMBING CODE, A.S.M.E. AND A.S.H.R.E. SPECIFICATIONS) ALL HEATING, VENTILATING AND AIR CONDITIONING EQUIPMENT WHICH ARE NOT OTHERWISE SHOWN ON THESE DRAWINGS. 40. THE SEWAGE DISPOSAL SYSTEM AND FRESH WATER SUPPLY SYSTEM SHALL BE AS REQUIRED BY THE LOCAL BOARD OF HEALTH. � '1L.1J ., 41. COPYRIGHT @2023 STUDIO A/B ARCHITECTS. REPRODUCTION OF THESE PLANS, IN ANY FORM WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT, IS PROHIBITED. THESE PLANS MAY NOT BE FILED FOR CONSTRUCTION PURPOSES IN ANY BUILDING DEPARTMENT, WITHOUT THE ARCHITECT WRITTEN AUTHORIZATION. ANY USE OF THESE PLANS FOR ANY PURPOSE, OTHER THAN THAT SPECIFICALLY AUTHORIZED BY THE DESIGNER, IS ILLEGAL, AND MAY SUBJECT THE USER THEREOF TO THE PAYMENT OF FULL COMMISSIONS. 023 7 Or N�= DESIGN CRITERIA TABLE R301.2(1) CLIMATE AND GEOGRAPHIC DESIGN CRITERIA GROUND WIND SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE SHIELD FLOOD SNOW SPEED DESIGN FROST DESIGN UNDERLAY HAZARD (h) LOAD (i) (mph) CATEGORY WEATHER- TERMITE DECAY TEMP. (f) -MENT (g) ING LINE (c) (d) REQUIRED DEPTH(b) 20 Ibs 130 C SEVERE 3'-0" MODERATE SLIGHT TO 11 YES N/A PROJECT TO HEAVY MODERATE Fisher Residence DESIGN LOADS LOCATION LIVE DEAD DEFLECTION LIMIT SLEEPING 40LBS 10LBS L/360 ROOM OTHER THAN SLEEPING 30LBS 10LBS L/360 ATTIC (NON STORAGE) 10LBS SLBS L/240 Structural Notes ATTIC (STORAGE) 20LBS 10LBS L/240 ROOF W/FIN. CEILING 20LBS(SNOW) 15LBS L/240 ROOF NO FIN. CEILING 20LBS (SNOW) 7LBS L/180 SNOW LOADS HAVE BEEN ADJUSTED TO REFLECT THE SLIDEOFF FACTOR,AS A FUNCTION OF ROOF PITCH. RAFTER SIZES MAY HAVE TO BE INCREASED TO ACCOMMODATE HIGHER SNOW LOADS. Project number 22014 Date 3/13/2023 Drawn by HA 0 Checked by GB M S . 01 N M Scale As indicated co studio a/b architects 651 West Main Street, Riverhead, NY 11901 631 5912402 631 3231426 glynis@studioabarchitects.com mailing address: PO Box 444, Orient, NY 11957 client: Ronald A. Fisher site address: 7130 Main Road, East Marion, NY 11939 tel: 914 714 4859 email: ronfis@aol.com tax map#: 1000-31.-6-6 X2 X5 X2 X5 4'- 1" 31'-01/2" ................. __ . _.._..... . ... . ............. ..............._......_............. - .___.._._.......__........._........._._.... -- - - ____.._...._ -- _..__.__ _-----� _�.,_. . ....__.._........_... . . _ _.__.. ........._._._...........__..........._.._..... _...............................................--._.._.._............__....t�_.__._..__.._........_..._..._......._....---..... ..T X1 X1 i i I I Y6 - - - -- --- -_ -- _ _ - - - I � i Y5 , �i CV I : G No. Description Date INSTALL 3"DIA HEAVY STEEL TUBE r COLUMN BELOW NEW STEEL GIRDER `L TO FOUNDATION IF ALTERNATIVE (2)-Ivl 1 3/4"X 16" IS USED, COLUMN MAY BE MIN. (3)-2X4 t�-' ------ -(Y4 _ J NEW STEEL G RDE X15 BELOW EXISTING ST LEV L ':. INSTALL 3" DI E L T BE i COLUMN BOTH ND . A RNATIVE: EW LVL GIR ER ( )- 1 3 4"X 6" 00 TOP FLUSH T EXISTING JOISTS. CUT EXISTING JOTS S AND UE E HANGERS TO ON ECT THEM TO I : INSTALL (3)-2X4 CO UM ON OTH I ---...__....._.................._._........_.._.................._....... - - - -- --_- - ____._-_..__....._.....__..._.__.._._.. - ................. _ ..._..............----.........................._..._._.......------.....__.._........................ iCY OPTION - ,O (THIS GIRDER WOULD NOT BE EXPOSED UNLESS OWNER DECIDED TO DO SO): ! p� i VERIFY MIN. (9)-2X10 OR (5)- 1 3/4"X 9 114" LVL I y IS EXISTING, IF NOT ADD TO MAKE IT. M I \� FILL FLOOR DECKING ! WHERE CHIMNEY IS FILL 2X10 REMOVED ... i REPAIR FIRST FLOOR GIRDER(S)AS NEEDED � r3 D !if��� VERIFY(3)-2X10 IS EXISTING �2V7B� Q� T y0 I 1 i I Y6 Y4 Y3 Y2 Y1 l I PROJECT °°x, Fisher Residence -------- ___ - - ___ ............... I I `0 ' I, ii I I I ..,R I _..........._..... _._..------... o F`° Decking Layouts AD Second Floor _ ®J 45' - 31/4" -- .. !, I FLOOR LOAD ---------- IiI i f J rh First Floor 13'- 10 1/4" W� 3 5' - 9 1/4" Project number 22014 I =Ell Date 3/13/2023 X3 Drawn by HA Q X4 X3 X4 Checked by GB v 1 First Floor Framing Second Floor Framing n N-S Section Load Path Diagram S . 02 if lit = 101-011 N O N M Scale As indicated co 2"VENT EXTENSION THRU ROOF Plumbing Fixture Schedule MECHANICAL NOTES: studio a/b architects � I t i t t ATTIC/ THIS ALTERATION DOES NOT INCLUDE MECHANICAL SYSTEM REVISION. CONTRACTOR SHALL EXAMINE 651 West Main Street# Room Fixture Type Product Finish Note , ROOF CONDITION OF EXISTING MECHANICAL SYSTEMS. PROPOSE ANY ADJUSTMENT, IF REQUIRED. Riverhead, NY 11901 1 CONTRACTOR ALSO SHALL EXAMINE EXISTING MECHANICAL SYSTEMS FOR THE ENERGY 631 591 2402 1 Kitchen Double Bowl Sink Determined by Owner CONSERVATION. ADD INSULATION ON PIPES AND DUCTS, IF NEEDED: I t 631 3231426 t t t t 2 Kitchen Faucet Determined by Owner CLOTHES gYnis@ I studioabarchitects.com t t I t t WASHER t I t 3.1 Bathroom 1 Lavatory Pedestal Sink Determined by Owner Systems WC LAVATORY i j 3.2 Bathroom 2 Lavatory Wall-hung Sink on vanity Determined by Owner If Vanity Cabinet specified on Bathroom Accessory 1 [403.4] HVAC piping conveying fluids above 105°F or chilled fluids below 55°F are insulated to?R-3. mailing address: t LAVATORY t SHOWER WC t TUB I cabinet Schedule is selected, sink is incorporated with the 2 [403.4.1] Protection of insulation on HVAC piping. PO Box 444, Orient, NY 11957 T-T" CabinetExisting piping shall be insulated, if not insulated. t3 [403.5.3] Hot water pipes are insulated to>-R-3. t t t 3.3 Bathroom 3 Small Lavatory Wall-hung Sink Determined by Owner; Recomended product: Nameeks https://www.build.com/nameeks-001400-u-one-hole/sl t t ( t Mini 14-3/4"Ceramic Wall Mounted/Vessel Bathroom Sink 782751?uid=4211840&searchld=c39uFDdvUP Ducts ROOF 2 ND FL 1 [403.3.1]Supply and return ducts in attics insulated >= R-8 where duct is >=3 inches in diameter and >= R-6 client: with One Faucet Hole- Includes Overflow 2"WASTE, PVC Model:CeraStyle Hot - Includes Hole where< 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter>=3 inches KITCHEN SINK __ and R-4.2 for< 3 inches in diameter. Ronald A. Fisher & DISH ---------------------------1 2"WASTE, PVC 4.1 Bathroom 1 Lavatory Sink Faucet Determined by Owner Existing ducts shall be insulated, if not insulated. LAVATORY SHOWER WC site address: WASHER 2"WASTE, 1 1/2 ( 4.2 Bathroom 2 Lavatory Sink Faucet Determined by Owner 1 PVC WASTE, r-- �-'I 4.3 Bathroom 3 Lavatory Sink Faucet Determined by Owner 7130 Main Road, East Marion, NY 119�9 t PVC I "WASTE, PVC tel: 914 714 4859 E 1t I I 5.1 Bathroom 1 Shower System w/Hand Shower Determined by Owner; Recomended product:American https://www.build.com/american-standard-9038-824/s 1 ST FL 1ST FL Standard Spectra Versa Shower System with Shower 1668622?uid=3948968&searchld=uVPF03wSll PLUMBING NOTES: email: ronfis@aol.com Head, Hand Shower, Slide Bar, Hose and Aqua Toggle tax ma #: 1000-31.-6-6 L2L"'WASTE, - � Technology ALL WORK SHALL COMPLY WITH NYS RESIDENTIAL CODE, EXISTING BUILDING CODE, PLUMBING CODE, pC 1P. Model:9038824.002 ENERGY CONSERVATION CODE,AND ALL APPLICABLE CODES AND REGULATIONS. 3"WASTE, PVC BATHROOM 1 5.2 Bathroom 2 Shower System w/Hand Shower Determined by Owner; Rcomended product: American https://www.build.com/american-standard-studio-s-sv- 3"WASTE, PVC 4" HOUSE WASTE REUSE EXISTING Standard Studio S Pressure Balanced Shower System 2/s1708390?uid=4033618&searchld=NaCR12zMKC 1. DRAWINGS ARE DIAGRAMMATIC AND SHALL BE USED IN LAYOUT OF WORK. DO NOT SCALE THE PIPING with Shower Head, Hand Shower, Slide Gar, Shower Arm, DRAWINGS. EXISTING OR THE EXTENSION Hose, Wall Supply Elbow, Ditd Valve Trim 2. COORDINATE THE WORK WITH THE REQUIREMENTS OF ARCHITECTURAL DRAWINGS FOR BASEMENT PP y verer, an Model:Studio S-SV-2.002 DIMENSIONS, LOCATIONS AND CLEARANCES. MAINTAIN MAXIMUM HEADROOM AND SPACE ® 5.3 Bathroom 3 Shower System w/Tub Filler Determined by Owner; Recomended product:American https://www.build.com/american-standard-tul05-502/s CONDITIONS. WHERE HEADROOM OR SPACE CONDITIONS APPEAR INADEQUATE,ARCHITECT SHALL 4 Plumb Waste Riser Diagram Standard Studio S Tub and Shower Trim Package with 2.5 1562663?uid=3710448&searchld=9c7WHgTjt8 BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. 3. IF DIRECTED BY THE ARCHITECT, MAKE MINOR MODIFICATIONS IN THE LAYOUT AS NEEDED TO N.T.S. __ ® GPM Single Function Shower Head PREVENT CONFLICT WITH WORK OF OTHER TRADES OR FOR PROPER EXECUTION OF THE WORK. r._._. LI Pr--_..-.... � ........... 4. ALL WORK SHALL MEET OR EXCEED LATEST REQUIREMENT OF NATIONAL, STATE, COUNTY, Model TU105502 002 -- - 8 Bathroom 3 Tub Determined by Owner MUNICIPAL AND OTHER AUTHORITIES EXERCISING JURISDICTION OF THE WORK OF THIS PROJECT; - -- j _Q 9.1 Bathroom 1 Toilet Determined by Owner with seat&cover ANY PORTION OF THE WORK WHICH IS NOT SUBJECT TO APPROVAL OF AN AUTHORITY HAVING --- __= -- -- -^ - 9.2 Bathroom 2 Toilet Determined by Owner with seat&cover JURISDICTION SHALL BE PROVIDED IN ACCORDANCE WITH NATIONAL FIRE PROTECTION tv 0 9.3 Bathroom 3 Toilet Determined by Owner with seat&cover ASSOCIATION REQUIREMENTS; COMPLY WITH APPLICABLE UTILITY COMPANY RULES AND� Q- REGULATIONS; COMPLY WITH OCCUPATIONAL SAFETY AND HEALTH ACT(OSHA) REQUIREMENTS. 10 Laundry Closet ashing Machine Drain Pan Camco Washing Machine Drain Pan-30"x 32"w/PVC white verify size with washing machine; Fitting Bilingual; Item#: 2075, or eq.2 https://www.ramco.net/washing-machine-parts-1/wash NYS ENERGY CONSERVATION CODE REQUIREMENT: j ing-machine-drain-pan-30-x-32-w-pvc-fitting-bilingual- Hot water pipes are insulated to>_R-3. I 20752 5. SECURE PERMITS AND INSPECTION CERTIFICATES AND TRANSMIT SAME TO THE OWNER AT THE COMPLETION OF THE WORK. 6. CLOSELY SCHEDULE THE WORK SO THAT WORK WILL BE INSTALLED AT THE PROPER TIME WITHOUT DELAYING THE COMPLETION OF THE ENTIRE PROJECT 7. WHERE THE WORK WILL BE INSTALLED IN CLOSE PROXIMITY WORK OF OTHER WHERE THERE IS EVIDENCE THATTHE WORKWILL INTERFERE WITH HE WORK OF OTHER TRADES, 1� ARRANGE SPACE CONDITIONS TO MAKE A SATISFACTORY ADJUSTMENT. IF WORK IS INSTALLED BEFORE COORDINATING WITH OTHER TRADES, MAKE NECESSARY CHANGES TO THE WORK TO CORRECT THE CONDITION WITHOUT ADDITIONAL COST TO THE OWNER. % 8. CONTRACTOR SHALL ADOPT EXISTING PLUMBING SYSTEM AND PROVIDE NECESSARY ADJUSTMENT ..,.::_.,Up,,.,....::......:....... i Up FOR THE PROPOSED CONFIGURATION. 9. CONTRACTOR SHALL VISIT THE PREMISES TO DETERMINE EXISTING CONDITIONS AND COMPARE -' UPi- SAME WITH DRAWINGS AND SPECIFICATIONS AND SATISFY HIMSELF OF ALL CONDITIONS PRIOR TO .._ THE SUBMISSION OF A BID PROPOSAL 10. CONTRACTOR SHALL EVALUATE THE EXISTING WASTE SYSTEM CAPACITY; NOTIFY ARCHITECT AND No. Description Date OWNER OF IF EXISTING CAPACITY IS NOT ADEQUATE. - ,......,._...,_,.,.;,., 11. CONTRACTOR SHALL RELOCATE AND/OR REMOVE OF EXISTING FIXTURES,ALLOCATE AND RECONNECT EXISTING VENTS, CAP UNUSED LINES AND CONNECTIONS OF NEW AND REUSED m EQUIPMENT TO WATER,WASTE LINES VENTS, DUCTS,AND LIKE. _ 12. ALL REMOVED EQUIPMENT AND MATERIAL SHALL BE REMOVED FROM THE PROJECT SITE, OR TO A r 1 r LOCATION AS DIRECTED BY THE OWNER. �; , -� -.._.._-_. _ 13. ALL EQUIPMENT SHALL BE LABELED WITH SYSTEMS SERVICE;ALL PIPING SYSTEMS SHALL BE IDENTIFIED AS TO THEIR CONTENTS AND DIRECTION OF FLOW; ALL VALVES SHALL BE TAGGED WITH TAGS AND VALVES CHART SCHEDULE FRAMED AND WALL MOUNTED WHERE DIRECTED. EXISTING USE OF THIS 14. CONTRACTOR SHALL INSTALL THERMAL INSULATING MATERIAL AROUND ALL HOT AND COLD PIPING. Bathroom 1 Y CHASE IS ASSUMED 15. NEW HORIZONTAL PIPES RUN UNDER FLOOR. PRIOR TO ANY EXECUTIONS, CONTRACTOR SHALL �� EXAMINE BEFORE ANY NOTIFY TO THE ARCHITECT, IF ANY DRILLING TO THE EXISTING JOIST OR GIRDER IS REQUIRED. 5 - - INSTALLATION 16. CONTRACTOR SHALL SCHEDULE CONNECTION TO EXISTING SYSTEMS AT A TIME THAT WILL BE - CONVENIENT FOR THE OWNER AND CAUSE MINIMUM DISRUPTION TO ALL PARTIES INVOLVED. 2 /2"WASTE ALL FIXTURES SHALL BE �,' _ I __= \. Bathroom 3 REPLACED 3/4_HW _ ALL LINES TO REMAIN AS - -- 3/4"CW =I--------- 1 - EXISTING Bathroom 2 j / ------------------------------ FT ---------------- t ! �.. I 1/2LWASTE- 0I / , , t I , - ----------- LINES FROM :7 ' BATHROOM 2 CONNECT ABOVE EXISTING EXAMINE EXISTING STRUCTURE FOR 7;�7 AVAILABLE PIPE RUNNING LOCATION WASTE OUTLETTO EXISTING SEPTIC WASTE OUTLET CONNECT WI DRILLING ON EXISTING STRUCTURE THOUT ARCHITECT'S APPROVAL TANK IN BASEMENT INV TO ELEV. 35" +/- FRO EXISTING j F.F. 1 I 1 REFRIGERATOR i �. QED A'1r7 I ; VENTLu o INSTALL IF 3 - NOT EXISTING Q y -+O .'�'i'crOF7a�'``O�11 N Li HOSE BIBB _..li co ' ,i I DW Kitchen I I I PROJECT I Fisher Residence I I--- I z�. Mechanical and Plumbing Notes g 1 Plumbing Layouts I Project number 22014 Date 3/13/2023 li Drawn by HA Q Checked by GB First Floor Plumbin La out n Second Floor Plumbing Layout 1/4" = 1'-011 MP . 01 co Scale As indicated co " Lighting Fixture Schedule LEGEND ELECTRICAL NOTES: studio a/b architects Lighting Fixture # Lighting Fixture Type Product Finish Bulb Note SURFACE MOUNTED PANELBOARD AND CABINET 1. DRAWINGS ARE DIAGRAMMATIC AND SHALL BE USED IN LAYOUT OF WORK. DO NOT SCALE THE 651 West Main Street, (EXISTING PANEL IN THE BASEMENT ON THE WEST DRAWINGS. Riverhead, NY 11901 A Ceiling Recessed fixture to be determined by Owner LED, 3000 or 2700K A, A2 and A3 maybe same adjustable WALL NEAR NORTHWEST CORNER, NOT SHOWN ON 2. COORDINATE THE WORK WITH THE REQUIREMENTS OF ARCHITECTURAL AND STRUCTURAL 631 5912402 DRAWINGS FOR DIMENSIONS, LOCATIONS AND CLEARANCES, 631 3231426 product DRAWINGS) 3. IF DIRECTED BY THE ARCHITECT, MAKE MINOR MODIFICATIONS IN THE LAYOUT AS NEEDED TO glynis@studioabarchitects.com A2 Ceiling Recessed Wall Washer or to be determined by Owner LED, 3000 or 2700K PREVENT CONFLICT WITH WORK OF OTHER TRADES OR FOR PROPER EXECUTION OF THE WORK. Adjustable fixture 4. ALL WORK SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE, LOCAL CODES AND UTILITY mailing address: 1 O CEILING RECESSED MOUNT LIGHTING FIXTURE COMPANY REQUIREMENTS,ALL APPROPRIATE MUNICIPAL AND REGULATORY AGENCIES, CODES AND PO Box 444, Orient, NY 11957 A3 Ceiling recessed shower light to be determined by Owner LED, 3000 or 2700K O-> CEILING RECESSED MOUNT WALL WASHER, OR B Wall mount wet location fixture to be determined by Owner LED, 3000 or 2700K ADJUSTABLE LIGHTING FIXTURE REQUIREMENTS. C Pendant fixture to be determined by Owner LED, 3000 or 2700K • CEILING SURFACE MOUNT LIGHTING FIXTURE D Ceiling Surface Mount Closet fixture to be determined by Owner LED, 3000 or 2700K I-O WALL MOUNT LIGHTING FIXTURE NYS ENERGY CONSERVATION CODE COMPLIANCE: client: E Exterior Wall mount fixture to be determined by Owner LED, 3000 or 2700K Lighting 1 [404.1] 75%of lamps in permanent fixtures or 75%of permanent fixtures have high efficacy lamps. Does not Ronald A. Fisher S� SINGLE POLE SWITCH apply to low-voltage lighting. �3 THREE WAY SWITCHH site address: LIGHTING FIXTURE NOTES: 1` 1. SCHEDULE AND LAYOUT ARE MADE WITHOUT INCLUDING EXISTING FIXTURES. THE CONTRACTOR SHALL EXAMINE EXISTING VDIM SINGLE POLE SWITCH W/DIMMER 5. CONTRACTOR SHALL PREPARE AND SUBMIT TO THE PROPER AUTHORITIES, FOR THEIR APPROVAL, 7130 Main Road, East Marion, NY 11939 FIXTURES,AND VERIFY WITH OWNER WHETHER HE IS WILLING TO REUSE OR REPLACE. ALL REQUIRED DOCUMENTATION. PROVIDE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS AND PAY tel: 914 714 4859 2. RECESSED CEILING LIGHTING FIXTURE SHALL BE 4" ROUND OR SQUARE WHITE TRIM, LED 11+/-WATT, INITIAL LUMEN 650+/-, BY WAC, S{DR DOOR SWITCH ALL LOCAL, STATE AND FEDERAL TAXES, FEES AND OTHER COSTS IN CONNECTION WITH THE WORK. email: ronfis@aol.com 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL CONTROLLED INSPECTIONS COOPER, OR EQ. DUPLEX RECEPTACLE REQUIRED BY APPLICABLE ADMINISTRATIVE BUILDING CODE. tax map#: 1000-31.-6-6 3. ALL REMOVED EXISTING FIXTURE SHALL BE STORED FOR OWNER'S REUSE. =()G DUPLEX RECEPTACLE PROTECTED BY 7. OBTAIN BOARD OF FIRE UNDERWRITER/LICENSED ELECTRICIAN CERTIFICATES FOR WIRING. GROUND CIRCUIT FAULT INTERRUPTER 8. CLOSELY SCHEDULE THE WORK SO THAT WORK WILL BE INSTALLED AT THE PROPER TIME WITHOUT DELAYING THE COMPLETION OF THE ENTIRE PROJECT. NEXT EXTERIOR DUPLEX RECEPTACLE 9. WHERE THE WORK WILL BE INSTALLED IN CLOSE PROXIMITY TO THE WORK OF OTHER TRADES, OR WHERE THERE IS EVIDENCE THAT THE WORK WILL INTERFERE WITH THE WORK OF OTHER TRADES, -® SPECIAL PURPOSE OUTLET ARRANGE SPACE CONDITIONS TO MAKE A SATISFACTORY ADJUSTMENT. IF WORK IS INSTALLED BEFORE COORDINATING WITH OTHER TRADES, MAKE NECESSARY CHANGES TO THE WORK TO UP USB RECEPTACLE CORRECT THE CONDITION WITHOUT ADDITIONAL COST TO THE OWNER. -- ® CEILING MOUNT SMOKE ALARM SYSTEM DEVICE 10. THE ELECTRICAL CONTRACTOR SHALL INSTALL ALL WIRING FOR THE MECHANICAL SYSTEMS CEILING MOUNT CO ALARM SYSTEM DEVICE REQUIRING FIELD WIRING,ACCORDING TO THE WIRING DIAGRAMS PROVIDED BY THE MECHANICAL _ TELEVISION OUTLET CONTRACTOR. 11. EXAMINE AND EVALUATE ALL EXISTING ELECTRICAL SYSTEMS CONNECTED TO THE PROJECT;VERIFY a TELEPHONE/DATA OUTLET CAPACITY OF EXISTING SERVICE WITH NEW LOAD REQUIREMENTS; NOTIFYARCHITECT OF -O FAN OUTLET CONDITION OF EXISTING SERVICE AND WIRING OF ANY OUTLETS NOT FUNCTIONING OR ILLEGAL; OTHERWISE,ALL EXISTING CIRCUITING SHALL,AS FAR AS APPLICABLE, REMAIN INTACT FOR REUSE; j LAYOUTS ARE NOT INCLUDING ANY EXISTING ELECTRICAL SYSTEMS. CONTRACTOR SHALL ADJUST THE OUTLET LAYOUTS WITH THE EXISTING ONES. ALL LIGHTING SHALL BE REPLACED EITHER JUST E THE FIXTURE OR INCLUDING CIRCUIT,AS PER EACH EXISTING CONDITION. i 12. INSPECT EXISTING CIRCUIT BREAKERS.ADD ADDITIONAL CIRCUIT BREAKERS TO THE SERVICE BOX _� AS NECESSARY TO CORRECT IMPROPER, UNSAFE WIRING. 13. EXAMINE AND EVALUATE EXISTING FIRE ALARM SYSTEM INCLUDING SMOKE, FIRE, HEAT, AND/OR CARBON MONOXIDE DETECTORS. AND PROPOSE ADDITIONAL DETECTOR/ALARM SYSTEM, AS _ REQUIRED, COMPLYING WITH ALL APPLICABLE CODES, INCLUDING BASEMENT, FIRST FLOOR AND SECOND FLOOR. CONTROL s ===� 14. ALL DUPLEX OUTLETS SHALL HAVE TWO DIFFERENT CIRCUITS. ❑� 15. ALL OUTLETS WITHIN 6 FEET OF WET AREAS SHALL BE GROUND FAULT CIRCUIT INTERRUPTER A2 (GFCI.), UNLESS OTHERWISE NOTED. 16. ALL NON-GFCI OUTLETS SHALL BE ARC FAULT CIRCUIT INTERRUPTER(AFCI). A2 A A2 A2 17. ALL CEILING RECESSED LIGHTING FIXTURES SHALL BE IC-RATED, SEALED AT HOUSING/INTERIOR (UUPP FINISH AND LABELED TO INDICATE 52.0 CFM LEAKAGE AT 75 PA. [402.4.51 3......_.. - � 18. INSTALL ALL APPLIANCES ON SEPARATE CIRCUIT. 19. BEFORE THE ROUGH WIRING SCHEDULE A WALK THROUGH TO VERIFY AT THE SITE ALL OUTLET LOCATIONS WITH ARCHITECT AND OWNER. DIM A -_- ,.. ,.., ... 20. LOCATE NEW SWITCHES TO MATCH HEIGHT OF EXISTING, UNLESS OTHERWISE NOTED. 21. LOCATE NEW RECEPTACLES TO MATCH HEIGHT OF EXISTING, UNLESS OTHERWISE NOTED. _,.i ,_ _ A !I �' 'T. 2 _ _--, No. Description Date F 22. LOCATE ALL SWITCHES SO THAT THE CENTERLINE OF THE FACEPLATE IS 5"FROM THE FINISHED -' == ( =m EDGE OF ADJACENT DOOR OPENINGS OR EDGE OF WALL UNLESS NOTED OTHERWISE. CEILING a I '.1 =' -a 23. GANGED MULTIPLE SWITCHES BEHIND A SINGLE FACEPLATE. u.:::..__ PADDLE FAN [Jill +; ( I + _ 1 24. THE CONTRACTOR SHALL SCHEDULE CONNECTION TO EXISTING SYSTEMS AT A TIME THAT WILL BE A2 A2 CONVENIENT FOR THE OWNER AND CAUSE MINIMUM DISRUPTION TO ALL PARTIES INVOLVED. _ 17 DIM- I = -- DR - 25. FOR SECURE SOUND ISOLATION THROUGH WALL NO SWITCHES OR OUTLETS SHALL BE INSTALLED 2 A A A ON A WALL BACK-TO-BACK. D 26. WHEN ANY SWITCH, OUTLET, OR WALL MOUNT FIXTURE, OR VENT SHALL BE INSTALLED ON EXTERIOR ❑\\ DIM WALL, THE BOX OR PENETRATION SHALL BE WRAPPED WITH SPRAY INSULATION. l s _ \ 27. PRIOR TO ANY INSTALLATION, SCHEDULE WALK THROUGH WITH THE OWNER FOR ALL OUTLETS AND DR D S G A2 A FIXTURES. - .. Irf Ai 2 A2 A2 - F b G A A A I DR EXHAUST FAN, DUCT ------- _._.....---.___..._..__..____. A3 ' %" ' - `I p Y A REUSE EXISTING, IF C ++ F WORKING CONDITION DIM D - --� (OWNER DETERMINE) -�__ G .__._............._' - INSTALL NEW WEATHER ___.._.__._.._.. ��� COVER I 6 +/-ABOVE COUNTERTOP L EXHAUST FAN, DUCT& VENT& 2 A2WEATHER TYP. WEATHER COVER COVER I j REUSE EXISTING IF DI DIM THERE IS ONE,AND IF IT CLOTHES WASHER AND A A2 REFRIGERATOR S s IS IN GOOD CONDITION (OWNER DETERMINE) DRYER DRYER VENT AND I WEATHER COVER IN CABINET OUTLET MAY BE ABOVE 6"+/-ABOVE COUNTERTOP A STUDY ROOF A A2 i a I -� ON CABINET BASE RANGE FOOD A A A2 RANGE FOOD VENT . -A WEATHER COVER - UNDER COUNTER I _ _..�� i ,�._ ;I �',.u.. _ N'.,•,e STOVE TOP OF CABINET is REAR PANEL j 1 r DW �,� 02378� 04 �OF NE B A A f t, 6" +/-ABOVE COUNTERTOP a TYP. i I i A ON CABINET BASE PROJECT UPA,- Fisher Residence G g( I I I EXT I I Electrical Layout i j -- .---- Project number 22014 Date 3/13/2023 Drawn by HA N Checked by GB M 1 First Floor Electrical La out n Second Floor Electrical Layout n _ i n ■ o N 1/4 - 1 -0 co E1 C) N co Scale As indicated co