Loading...
HomeMy WebLinkAbout50599-Z rt~ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50599 Date: 4/26/2024 Permission is hereby granted to: Fliss, Janice 565 Old Main Rd Mattituck, NY 11952 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 565 Old Main Rd Laurel SCTM # 473889 Sec/Block/Lot# 122.-7-2 Pursuant to application dated 3/20/2024 and approved by the Building Inspector. To expire on 10/26/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO-ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT r A s Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 htWs: v.southoldtownny.gov Date Received BUILDINGAPPLICATION FOR For office Use Only PERMIT NO.--�56Building Inspectors - "It Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 3 y OWNER(S)OF PROPERTY: Name: o�S SCTM# 1000- 2Z dJ '67• aD -wZ GU Project Address: to ��� /i/ ( qE Phone#: Email: s Mailing Address: Ill �' /ot LL ia'd f: CONTACT PERSON: AlName: nl- Mailing Address: ' , a Phone M. J/ &" Email: DESIGN PROFESSIONAL INFORMATION: Name: Mlqh+� `' .� ral la w MailiingAddress: � GtVl d 26 20 l Phone#: `. �7 e� Email ,f✓ P,e�CONTRACTOR INFORMATION: ld� Namet;A Mailin , Phon Email: Z " Zt2- DESCRIPTION OF PROPOSED CONSTRUCTION ❑Ne :St ct re ❑AdditionAlte p ` stimat Cos of Prration ❑Re air ❑Demolition Ethe G $ Will the lot be re-graded? ❑Yes o Will excess fill be removed from premises? ❑Yes o 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants a restrictions with respect to this property? ❑Yes o IF YES, PROVIDE A COPY. M'70eclk Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPUCATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210A5 of the New York State Penal Law. uthorizedent A ❑Owner Application Submitte By(print name): S Y�Q ��il// !� g Signature of Applicant: Date: STATE OF NEW YORK) COUNTY OF being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the �e, A5-- �� — (Contractor Agent, rporate Officer, etc.) of said owner or owners, and is duly authorized to or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ��I _lkday of Notary lic PROPERTY OWNER, AUTHORIZATION y r.} ra (Where the applicant is not the owner) t'°V( residing at , i1 .� do hereby authorize _ to apply on my h If to the T n SoOthold Building Department for approval as described herein. L Owner's Sig ature Date WWI SS Print Owner's Name 2 v"o K workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. 202 Commerce Dr., Ste. 7 Moorestown, NJ 08057 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) The Prudential Insurance Company of America Town of Southold 53095 Route 25 3b.Policy Number of Entity Listed in Box 1a Southold, NY 11971 CG-52830-NY 3c.Policy Effective Period 1/1/2024 To 12131=24 4. Policy provides the following benefits: a A.Both disability and Paid Family Leave benefits. ❑ B.Disability benefits only. ❑ C. Paid Family Leave benefits only. 5. Policy covers: A.All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disabilityand/or Paid Family Leave benefits insurance coverage as described,ab e, � Y Date Signed January 02, 2024 By of insurance car(Signature �.'�" 's authorized representative or NYS licensed insurance agent of that insurance carrier) Telephone Number 215-658-7318 Name and Title Carolynn Smith -VP Contracts IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law.It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acce ince Unit,PO Box 5200,Bin hamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if Box 48,4C or 5B have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees, Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 111111111°°°1°1°1°°1°1°�1111°°11°111°III II Y Workers' CERTIFICATE OF STATE Comp Boardensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 225 Bush Street Suite 1400 1c.NYS Unemployment Insurance Employer Registration Number of San Francisco,CA 94104 Insured 50-66426 4 Work Location of Insured (Only required if coverage is specifically limited to certain locations in New York State,i.e., 1 d.Federal Employer Identification Number of Insured or Social Security a Wrap-Up Policy) Number 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage(Entity 3a.Name of Insurance Carrier Being Listed as the Certificate Holder) AMERICAN ZURICH INSURANCE COMPANY Town of Southold Town Hall Annex Building 3b.Policy Number of Entity Listed in Box"l a" 54375 Route 25 P.O.Box 1179 WC 6142876-02 Southold,NY 11971 3c.Policy effective period 10/01/2023 to 10/01/2024 3d.The Proprietor,Partners or Executive Officers are included.(Only check box If sH partners/officers included) all excluded or certain pad mers/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box 1a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be lusted under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by tho insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Mark AN (Print naa/m��e of authorized/representative or licensed agent of insurance carrier) Approved by: 71'GGi/1,/Pi�CQ(;1�G 10-01-2023 (Signature) (Date) Title: VP/Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (415)946-7500 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov SUNRINC-02 r TWA11G, CERTIFICATE OF LIABILITY INSURANCE DATE 9 MI202 YYY) /1 r2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. if SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemen s PRODUCER License#OC36861 Tanner ,.,....''. Alliant insurance Services,Inc. IAx ���wcr Walter A/c E 560 Mission St 6ttl l=l PRONE � .._...._. ...wA+�l San Francisco,CA 94105 n 1 alterjann"alliant corn _ INI ERd$)AFF4RWGATk/� IIIIE MAIC# �8,D1 --. ... 35378 .. ,.. INSURED INSUIRERB ZI,r.,r!ch Attlerican IrV GN,?CII' .M:II_Ce Carl arw r.. ._ 1 , ,5 „m„_.. Sunrun Installation Services,Inc INBFIERO a4rerir* #t. uaich jms►?Irart IIrnpartir 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 LItrftmmlw San Luis Obispo,CA 93401 ..� wsuRryll F COVERAG9§ CERTIFICATE NUM REVISION NUMBER. THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, MAY HAVE REDUCED BY PAID CLAIMS. irisri EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.i-U-6 LIMITS SHOWN NUMBER BEEN RE'6Gd �m _ ,,,,,,.,,,,, LTR TYPE OF INSURANCE POLICY �tl LIMITS CY EFF P 0,000 A JX COMMERCIALculMs--MADEIGENERAL LIABILITY DAMAGE � � )......... 1,000,0 0 ury NC 0 occuR MKLV5ENV104332 10/1/2023 10/1/2024 100 '00� P RSONAL&AOV INJURY gA 2,000,000 X N..POLICY X PRO- Ar l PER: ,—.-^ .......0E �� 2,000,000 JECT .._Up LOC Per Project AggmPAGG, ' .,_ .. 5,000,0�0'0 .eT i X OTHER:Retention: 200p000 r COMBINED B AUTOMOBILE LIABILITY _ .,. .n GNG1E LIMIT 2 000,000 X D , .w.$ANY AUTO BAP614287702 10/1/2023 10 1 20 BO lky INJU PRYApPUe%9n).._ _,....._ _m____ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY jeer AMAGEaccident S ,, rAA FAiaOPE Ded.: N� d Llalll Ded ..... .. 1,000,000 X c$oNtY X nN o N UMBRELLA LU1B OCCUR EF�Ct„#OCCURR,ENQE ,.,.....„,„,. ...__ _......... EXCESS LIAB CLAIMS-MADE AGGR, GATE --.... m._.._�... ..,... ,,,,.,..._ ,.w.......................... ED RETENTION$ C WORKERS COMPENSATION Y N.N X R _TH g�� Nµ N/A OT ..,�T.A7f�lT�... EMPLOYERSff 1,000,000 OFFCWM�MTOR/�LIABILITY wp,ECUTIVE E L.EACH ACCIDEN„ „ � -,F,,,,,,, _ ,FIdEo fl) WC614287602 10/1/2023 10/1/2024 E.L. Y�ISEASE-�EA MPLOXE, .1,000„000 If yes,describe under ,000 DESCRIPTION OF OPERATIONS below E ❑ISEAS -POLJCV LIMIT DESCRIPTION OF OPERATIONS I LOCATION,$I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Evidence of Insurance CERTIFICATE OLDE CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Route 25 Southold,NY 11971 AUTHORIZED REPRESENTATIVE U ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD se5yJK n' ` (//JJ 1 `ER ENG NEERING,CO. S6 Sq March 18,2024 RE: CERTIFICATION LETTER Project Address: JANICE FUSS RESIDENCE 565 OLD MAIN RD MATTITUCK,NY,11952 Design Criteria: -Applicable Codes=2020 NYSRC,20181RCIIBC/IEBC,ASCE 7-16 and 2018 NDS' -Risk Category=11 -Wind Speed=128 mph,Exposure Category B,Partially/Fully Enclosed Method -Ground Snow Load=25 psf -ROOF AR-01 &AR-02:2 x 6 @ 24"OC,Roof DL=7 psf,Roof LUSL=19 psf(Non-PV),,Roof LUSL=12.5 psf(PV) -ROOF AR-03:2 x 10 @ 16"OC,Roof DL=9 psf,Roof LUSL=20 psf(Non-PV),Roof LUSL=16.1 psf(PV): ' -ROOF AR-04:2 x 10 @ 16"OC,Roof DL=9 psf,Roof LUSL=19 psf(Non-PV),Roof LUSL=13.2 psf(PV) To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of PV Solar System on the roof.The structural review applies to the sections of roof that is directly supporting the solar PV system. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. •, „ Additionally,the PV module assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. Sincerely, 5 t`oF�NEWy� Digitally signed by Manouchehr _= A Hakhamaneshi �� 10.982 Date:=2024.03.18 °bsroe>; 10:54:24-04'00' Mighty Engineering Co 11709 Roxborough Rd Charlotte,NC 28211 1 (986)689.9776 1 info@mightyengineeringco.com pg 1 of 8 -SHEET INDEX SCOPE OR WORK GENERAL NOTES PAGE 0 DESCRIPTION •SYSTEM SIZE:6600W DC,6000W AC PV-1.0 COVER SHEET •MODULES:(17)HANWHA O-CELLS O PEAKDUO ELK ALL WORKSHALL COMPLY WITH 2O20 NEWYORK STATE RESIDENTIAL CODE ML-G70+YT400 - WITH 20181RCABCAEBC,MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS PV-10 SITE PLAN •INVERTERS:(1)SOLAREDGETECHNOLOGIES AND INSTALLATION INSTRUCTIONS PV-3.0 LAYOUT SE6009H-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. •RACKING:TOPSPEED,ATTACHMENT DETAIL MOUNT TO PV4.0 ELECTRICAL WOOD DECKSNR:DC•300M •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. - �P,`�QrNEWpp PV-5.0 SIGNAGE _ -PHOTOVOLTAIC SYSTEM ISUNGROUNDED.NO CONDUCTORS ARE SOLIDLY h `.jfNR RA,'jJ GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 69035. * aJ 71 n •MODULES CONFORM TO AND ARE LISTED UNDER ILL 61730. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741 ' `� 103982' •RACKING CONFORMS TO AND IS USTED UNDER ILL 2703 p�FE$$IQNp� •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II ,I MODULES,ARE CLASS A FIRE RATED. D Ig Ital Iy S`I g n� eUy •RAPI D SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL %./.�� � CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). by,IVIa nou Ch eh r M •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G) W a kha ma n esh i •ARRAY DC CONDUCTORS ARE SIZED FOR DEBATED CU RRENT. Date ZOG4.�3.1H •12,IS AMPS MODULE SHORT CIRCUIT CURRENT. 1 Date: 3 -04bOl •15 23 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)8 6W 8(B)[ sunrun ABBREVIATIONS VICINITY MAP 00B25-ME u1ePx,rmccuPPExr ": - _ — .: :i•' " Afr wcrwvcwcmrixlEPaPrtfl av ^ _: y CUSTOMER RESIDENCE - - � w•0: _ JANICE FUSS `0' Ij� - 565 OLD MAIN RO MATTITUCK sosvox •O.' • - " :: f� NY.11952 PERCVflPEM � m - TEL.I01T)9949999 rtI Exusnm r /I APN:1000-U2 M7-00-000-000 Esa ExEP0YSIDP ESY51Eu ` J� PROJECT NUMBER: us vux uxmcErnxu ;'♦ " 3° `,1 216R-565FLI$ n+� - _ DESIGNER. (415)000.6920 eXJ - �. - rsrr,e NMPexmxuEmm ;;4.us ! _ EJ AGUIBA P w sxsT.Tl. w v p 1'. SHEET COVER SHEET Pso flaam sxMooxn oE4^cE .�� - .V-- -+•,^ . REV.A VIBM024 ( - — PAGE PV-'I.O SITE PLAN-SCALE.3132'a 1'.0'. SITE PLAN DETAIL-SCALE v 11128•v 1•-D° (E)GATE (E)DETACHED STRUCTURE " (E)FENCE ROOF PATHWAYS IT TYP) Q' E)FENCE (E)DETACHED STRUCTURE --(N)ARRAY AR-04 (E)DRIVEWAY (N)ARRAYAR-03 - µ '�PSEDF NEWW-, � 5 4arL0R HA,yy'`yf _ = m FIRE SETBACKS s (I r..T.YP) � 103982 �V (E)RESIDENCE Ni rBE INV AC (N)ARRAY PR-02 sunrun 0 00825 E (N)ARRAYAR-01 wwm v.+s*war xr��sm _ ARRAY TRUE PVAREA CUSTOMER RESIDENCE: ROOF PATHWAYS PITCH AZ1M (SOFT) JANICE FUSS 565 OLD MAIN RD.MATTITUCK, (3'7YP) - AR-01 31' 254° 83.d NY,11952 .. AR-02 31° 74° 423 _. AR-03 20• 254° 126E TEL.(917)"9 I)N9 APN:1(M0-1U4)"74)0.002-000 AR-Od 29• 74° 126.8 PROJECT NUMBER: _ 2%RS65FUS LEGEND BM SUNRUN METER D AC DISCONNECT(S) EV ELECTRIC VEHICLE MD MICROGRID GROUNDING uoou es DESIGNER: a15)560.692o eX SUPPLY WUPMENT INTERCONNECT DEVICE ELECTRODE EJAGUIBA xou„itrs iu:csxn DC �L— ENERGY STORAGE r�INTERIOR EQUIPMENT SHEET PM DEDICATEDPVMETER DC DISCONNECT(S) L MA METERADAPTER , SYSTEM L J SHOWN PS DASHED 7GoPussFE� SITE PLAN SE SERVICE ENTRANCE SP SUB-PANEL INV INVERTERS) O ACREL METER BI BACKUP INTERFACE O�YvI ESUNICATION BG .BA' 1P GATEWAY IREV.A 3/182024 MP MAIN PANEL LC PV LOAD CENTER E®SOLAREDGEMETER CB 10 COMBINER BOX BP BACKUP LOADS PANEL STORAGESYSTEMGY GP GENERATIONPANEL PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MM DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Datail Edge(LANDSCAPEIPORTRAIT) Overhang Overhang SNOW LOAD:25 PSF COMP SHINGLE- TOPSPEED,ATTACHMENT DETAIL,MOUNT WIND SPEED: AR-01 1Story 2X6 RAFTERS 70'-3" 24" 22 1'-6" 0'-10' S GUST TOPSPEED TO WOOD DECK SNR-OCJ0004 FASTENERS: COMP SHINGLE- TOPSPEED,ATTACHMENT DETAIL,MOUNT (4)414 X 2 25"SS SEALING AR-02 TOPSPEEO 1Smry 2X8 RAFTERS 10'-4" 24" TO WOOD DECK SNR-OCJ0004 2Q 7 -6 0'-10" WASHER WOOD SCREWS FULLY COMP SHINGLE- TOPSPEED,ATTACHMENTDETAIL,MOUNT PENETRATING THROUGH WOOD AR-03 TOPSPEED 1-Story 2X10 RAFTERS 15'-5" 16". TO WOOD DECK SNR-DCJ0004 212 1'-6" 0'-1D' DECK COMPSHINGLE- TOPSPEED,'ATTACHMENT DETAIL'MOUNT - AR-04 TOPSPEED 1-Story 2X10 RAFTERS 9'-0" 16" TO WOOD DECK SNR-CC-30004 22 7'-6" 0'-iD' D1-AR-0I-SCALE:3/1V T-0" - D2-AR-02-SCALE:3I116"=1'-0' AZIM:254' - AZIM:74' PITCH:31' PITCH 31' Pit _;;^ 2•­8•• e IS 19-5. ' � 103962 Z'VtESSIU 3-9 19, s u n ru n ,D3-AR-03-SCALE:118'=1'1' ,. D4-AR-W-SCALE:118"=1`-0' .AMM:254' I NSTALLERS SHALL NOTIFY ENGINEER OF: A21M:74'. 0082SME PITCH:20' ANY PITCH 29' w.nwra POTENTIAL STRUCTURAL ISSUES 03SERVED r1'-3" � ��e•+ ` �w���"® PRIOR TO PROCEEDING W/INSTALLATION CUSTOMER RESIDENCE: -MOUNT NUMBER FOR LEADING }I - JANICE FUSS DO MOUNT E 1'-11" EDGE SHALL MATCH REQUIREMENTS USTED 2,-0" -5650LD MAIN RD,MATTITUCK, ABOVE INSTALL PER TOPSPEED NY,119U INSTALLATION _. 'I MANUAL Tit-(917)99F9999 6 APN 1000.122A0.07.00-002-000 -CONTRACTOR MAY SUBSTITUTE PROJECT NUMBER: 13'-11" SNAPNRACK _ - I 216R565FUS DECKTRACK MOUNTS(SNR DETAIL SNR-DC-00453)WITH A MAX OVERHANG OF 6 DESIGNER: - (415)5e46920a3 EJAGUIBA SHEET 2' LAYOUT' REV.A 3/78QO24 i -I3'-" —611^— 14-3. .. .. . . _ PAGE PV-&0 120/240 VAC SINGLE PHASE SERVICE METER#. M PSEGLI 98366514 ACC#:9694142003 NOTE:TOTAL PV BACKFEED UTILITY 31.25A - GRID USED FOR INTERCONNECTION SUPPLYSIDETAP CALCULATIONS E W y'�5�O0.X0# .per (N)LOCKABLE fw EXISTING 200A BLADETYPE SOLAREDGE TECHNOLOGIES: - 108135 (END FED)) DISCOONNNNECT Vc MAIN BREAKER FUS SE6000H-USS3 F F($$(ON Q` 3 fi000 WATT INVERTER duNCTION Box PV MODULES ' OR EOUNALENT EXISTING /• 2 1 / MLAG OA/I'400LLS.O.PEAKOUOBLK D( (tall 200A MAIN a /" ,(�j// ML-Gl0DULES _ g 'J signed,' PANEL — -T OPTIMIZERS WIRED IN: by Nestor O 35A FUSES ter' (1)SERIES OF(9)OPTIMIZERS �w SQUARE D LOAD RATED DC DISCONNECT (1)SERIES OF(8)OPTIMIZERS Houghton D222NRB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A COMPLIANT S440 Date:2024.03.18 1201240VAC 10:55:23-04'00' CONDUITSCHEDULE 0 CONDUIT CONDUCTOR NEUTRAL GROUND sunrun 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER - 2 1PVC OR EQUN. (4)10 AWG THHN/IHWN-2 NONE (1)10 AWG THH N/THWN-2 D082S-ME 3 1PVC OR EQUIV. (2)BAWGTHHNITHWN-2 (1)1DAWGTHHN/iHWN-2 (1)8AWGTHHN/R1NM-2 was e�os�.savw - 4 1PVC OR EQUIV. (2)6AWGTHHN/THWN-2 (1)8AWGTHHNRHWN-2 (1)8AMTHHN/THWN-2 CUSTOMER RESIDENCE' - .J5OL FUSB 565OLD MAIN RD,MATTRUCK, NV,11952 MODULE CHARACTERISTICS'. TEL(917)998-9999 HANWHA QCELLS:Q PEAK DUO BLK SUO OPTIMIZER CHARACTERISTICS: APN:1O0 0.12 2-09 41T-00-0 92 410 0 0. 400W MIN INPUT VOLTAGE BVDC ML-G10HT 40 IN OPEN CIRCUIT VOLTAGE: 400W MAX PUT VOLTAGE: 60VOC PROJECT NUMBER: MAXPOWERVOLTAGE: 3&0)V MAX INPUT ISC: 145ADC 216RS85FLI5. MAX OUTPUT CURRENT: 15 ADC DESIGNER: SHORT CIRCUIT CURRENT. 12.18 A 415)580F9M e4 EJAGUIBA SYSTEM CHARACTERISTICS-INVERTERI SYSTEM SIZE: 6800W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 9V '- ELECTRICAL SYSTEM OPERATING VOLTAGE 380V ' MAX ALLOWABLE DC VOLTAGE: 480V REV:A 3/182024 SYSTEM OPESHORT ING CIRCUIT CURRENT. 30A - SYSTEM SHORT CIRCUIT CURRENT. 30A PAGE PV-4.O INVERTER I I{i 7�10NDTA!QLOADI NOTES AND SPECIFICATIONS SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC W1T MTICLE PHOTOVOLTAIC11021(B),UNIESS SPECIFIC INSTRUCTIONS ME REQUIRED BY SECTON 69QOR IF REQUESTED BY THE LOCAL AW RMAXIMUM SYSTEM 4 4gp F •SIGNSANDLMEL$SHALL ADEOUATELVWMN OF HAZARDS USING EFFECTIVE MAXIMUM CIRCUIT 4 RRENr ADC WORDS,COLORS AND SYMBOIs, SIDES M4YBE ENERCa®PI •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING Tl�OPEN POSITION LABELLOCATION MAX RATED OUTPUT CURRENT L METHODMDSHALLNOTBEHANDWRITTEN PHOTOVOLTAIC AC COMBINER(IF •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT APPUCABIE , L •L L•L a L L I INVOLVED AELLOCATION PER CODE(SI •SIGNS AND LABELS SHNL COMPLYWITH ANSI Z535 L2011,PRODUCT SAFETY NVERTER(SI.AUDC016CONNECT(S), NEC 201270512(B)(2N31(d LABEL LOCATION SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPUCABIE) INVERTER(SI.DC DISCONNECT(S) •DO NOT COVER EXISTING MANUFACTURER LABELS PER CODE(S)CEC M19 69013(BA NEC PER CODE(S)NEC2017 55053 BOI7.6W 13(B) - L.l �,a DUAL POWER SUPPLY PoxERswRCEDDmuraowrECTsn+ Bouaces:unuTrGwo ' ' - OF NEW OD NOT RELOCATE THIS AND PV SOIARELECIRIC yt��OR HOOC/.O•pf OVERCURRENTDEVICE SYSTEM * =4A LABEL LOCATION LABELLOCATION ADJACENTTOPVBREPXER(IF UTILITY SERVICE METER AND MAIN APPUCABLEI SERMCEPANEL PER CODE($)CEC 2019. ...PER CODE(S)CEC 2019 70512(8)N).NEC -- 2 W512(B,V'2N3)1B).NEC WIT. 2017.705.12(BN31 305.12(BN2N3)@ 109135) TO108135 BUILDING SUPPLIED BY UTILITY GRID AND PHOTOVOLTAIC LABEL LOCATION SYSTEM INSTALLED WITHIN 3 OF RAPID SHUT DOWN SWITCH PER CODE(S)CEC=19.6906SCH3),NEC 201T.639.0Q .QFC H 1 I12 2012 605 111,IFC 2018 $u n ru n 4W 5],CFC2019 122012 . G�/!.1 �Lp L�Ls cy{ 4' 1l� /� P9f]C ®IQ�--1 SOLNR 1 V S 1 EM EQUIPME 1 B 00825 ME WITH RAPID SH TDO PJ o0 oa rew.,...m CUSTOMER RESIDENCE: - "' Pv SYSTEM JANICE FUSS DISCONNECT-EXTERIOR 565 OLD MAIN RD.MATTITUCK, LABELLOCATION- - GND FLOOR NY,11952 INTERIOR AND EXTERIOR DC CONDUIT EVERT IOFL INTERIOR AT EACH TURN,ABOVEAND BELOW PENETRATIONS, 3" TURN RAPID SHUTDOWN , MAINPMEL- ONEVERYMPULLBOX CONTANING DC CIRCUITS SWITCH TO THE"OW `-<R BASEMENT TEL.(BI])99&8999 PERCODE(S)CEC20lT6W31N3X3L6M31[G)(4). POSmONTO SHUT DOWN"' APN ID0D-M41047-00-002-000 NEC 201T.69031(G)(3).690 31(GN4)IFC 2012. 60511.1A _ PVSVSTEM AND REDUCE LASH.UMATION. PROJECT NUMBER: SHOCKHAZARD INTHE POINT OF INTERCONNECRON ARRAY. IPER CODE'NEM90 WS),NEC7p510.225]T,ZfOZES 216R-565FUS DESIGNER' (415)58MM IM3 EJ AGUIEA SHEET LABEL LOCATION' LABEL LOCATION - SIGNAGE ., AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT I A(3 FT)FROM THE SERVICE ' INTERCONNECTION DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S).CEO ZlB 69064.NEC 2017 69054 MECONNECTED _ _ "' REV.A 3/162024 PER CODE(S)CEC M14690 W(C)(1)(a),NEC 201T. a1066(0)OHa) PAGE PV-5.0 powered Is/ de::�d 'acwvs�P • .'OCElLS ((rI ra��/� a-``1, Oue9ry•TaLLae le.4ee]2597 ' O.ANTUM TECHNOLOGY:LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area,lower BOS costs,higher power classes:and an efficiency re(e of up to 19.9%. /� INNOVATIVE ALL-WEATHER TECHNOLOGY C-, - Optimal yields,whatever the Weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE ' Long-term y'eld securitywith Anti LID Technology,Anti PID O, Technology',Hot-Spot Protect and Traceable Quality Tra.QTM. EXTREME WEATHER RATING High,-tech alum'n:umelloy from",cart fled for high snow(5400Pa)and wind loads(4000Pa). .A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty'. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cult"edge cell separation Imo' and innovative wiring with Q,ANTUM Technology, ' ' . . .{AVT IestcaWIronsacmr6m0ro iEC/T56180e-1:4015,meVioda 1-1500V.I6ah) +Sea date shoe{onreer loi IaNer inloeno{ron THE IDEAL SOLUTION FOR: � Rooltopeveyson 'Roollop mrays on •. . resi0anliel bnldiras ¢omnerfi9l end indusldalbuld'eigs Engineered in Germafiy - Q'CELLS • 'MECHANICAL SPECIFICATION ' ' Formal 6631n x39.4in x 1.26in(including lreme) .(1685mm x 1000nvn x 32inm) -- - ++'uxs•-+ —aarmoM ' Weight 'Al'21b5(18.7kg)Front Cover 0.13in(3.2irim)thermellypre-s essedgWswilh + _ enl4rellection technology :. •e-'+�•�•eurna .,.e� Back Covoi .. "Cliriiposltehb0 nr L+•I Frame ' 'Black anodized aluminum Cell 6 x 20 mdrocryslelfno O.ANTUM solar haNcells" x•-°m...r Junction aos 2.093.981nx126.2.361nxO59-O.711n s (53-101mm x 32-60mm x 15-18mm),IP67,with BYAoss diodes Cable 4m6t Solur bl ;(+)>_43.3in(1100inm),(-)z43.3n(1100mm) ••e.•c•x•. Connector Slauin 5-6.Henwhe TCEL(S HOC 4Ampeenol llTX, Renhe PV2e:,IP67 TLrCe61eD15,.IMTHY JM601;IP68a ..11-sx-m:.+ cruse^O°leu'"I Friends PV2e;IP67 .: --- saxns•.a ELECTRICAL CHARACTERISTICS POWER CLASS -;' " : : : : - '• 316-; • '" : :: 320 :325' 336•: MINIMUM PERFORMANCE AT STANDARD TESTCONDITIONS,STC1(POWER TOLERANCE s5111 Poweral MPPs :., P,4m (WI 315 320 325 330 E Short Circuit Currents . Im JAI 099 10.04 : 1010 1015 E Open Circuit Voltage, V. (VI 3984 40.10 40,36 4062, . Current at MPP 1. 'JAI 951 956 9.61 967 Voltage at MPP. ,V.,v„ IVI 33.14 33.47 3381 3414 Efficiency' R J%I t18.7 G19.0 >_39.3' z196 MINIMUMPERF.ORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' Poweral MPP "" P.... ','(WI 2359 239.6 ,2434 247.1 E Short Circuit Current Isp (A) 8D5 809 814 8.18 F Open Circull Voltngo Vac ' IVI 3756 3'L81 38.06: 3831 • 2 Current at MPP' : j'IWy (A) 7..48 7.52 757' 7.61 Wwga at MPP V.,, „ IVI 31.53 3L85 32.17 ...32AB "•'Measurementlolerences Pu.t3%;Ik,Vkt6%at STC,SOOOW7m•.25t2'C;AML6aecordinglolEC609043•'SOOW/mj NMOT.Sp Uwn AM1.6- ••• OCELLSPERFORMANCEWARRANTY ••• i.: : . VERFORMANCEATLOWIRRAOIANCE ' .. .. . .. 6! o`Inst"98%al nolinn aldWi I <'..n F a t g. _.•.".�.�-.-.....•....••• tlegretlaUgri pei•yeor,Al long 931% oast 85%l power upml0 years.Al C -., . I ... of nominal power up to 25y65% A9Wlawthnmeasmemenitolelanc- • ) i S a es F.Uwe,renthsiri eotbitleneewlN § mewanwNYtermegl me O CELLS .u.n.ss�unn z E sale90r901tiNliondy9w mspeclive I•" n n ccUnlry.• vesm•-.r• :•.-. w u•..•.r+w..a al peulomance under low InadiancecCAm comparison to STC conditions(25-C,1000W/m2) ' q ' ,TEMPERATURE COEFFICIENTS, •• = " ' 'Temparmure Coefficient of l,v g (%IKI• •1004 Temporamre Coallipium olV« V 1%/K) -0.27'_ remporaldre Coatfiacnl of Pv.r ,V '1%/9I -0,35 Normal Module Operating T6mporaium NMOT (•FI 109t5A(43t3-C) �. 6 PROPERTIES FOR SYSTEM DESIGN - yg� .. ..ptaaimdm System Volte90 V,.i.. .IVI 1000(IEC)/1000(UL) Snfnly Cl.iss .. II ' q Maxinmm Series Fuse Rating JA DCI 20 Fire Raying bated Ion ANSI/UL 17D3 COEC)/TTPE2(UL) Y Mnx Dovgp,Loatl,Push/Pull' (lbs/161 75(3600Pa)/55(2667Pe) Permitted Module Tumpamtu,,e ,;-40•F up to H85•F e. Ma+ Tesrlond,Push/Pull' „(MIlli+I _ 113(5400Pa)/84(4000Pa) on Contlnuoua Duty (-40.•Cupto+85•C) O "See Wlal'alon Manual L QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION M, UL!703.VDEOUM,tyTesled.CE-comWwnl,IEC612152916.IE6617302010: NUMbei of Modolas per Pellet 32 9 ?pp?Cavan Cosa 11,V.S Patent No;9,893,215(solar cars) Number of Pallela pnr 5j'Trailer 30 Number of Pallets per 40'HC-Container : 26,• CC: 'Pellet Dimbnsions(Lx WxHI 69.3+•153+489mJ1760 x1150k L190mm) `e Pullet We,ght 1415lbs(642kg) - None: laOalOnuulrucaommwlbe 14E0wed:See the nslaletM aMoperaluy iNnvalor contact our techncicetlepwlmanllm WMn mlormeuenoneppreved,nslelbUonend use Ol ln,hs Pllan . . .. , OduCl. � � - HanwhiS O CELLS Am irlei Inc. 400 Specinum Center Drive,Suite 14001rvne,CA92618.USA TELsL 949 748 59 961 EMAa6r4Pky@u1q-ce11swm l WED vnwq-cekvn ' solar=@@ • Single Phase Inverter with HD-Wave Technology : .. for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE7600H-US/SE10000H-US/SE1140OH-US FF- - . . . . :0 solar 3kt• e solar=-- N17. ry -7 �er'1Z'W ll 4 � 0 . d O ,O O o e o Optimized installation with HD-Wave technology a Specifically designed to work with power optimizers - Record-breaking efficiency 'i . Fixed voltage inverter for longer strings' Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690A2 i UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors ' Built-in module-level monitoring IIIIIIIIIII wave A, 1 .. . — Outdoor and indoor installation �t C1 VP.. Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) I � f i www.solaredge.us 'Single Phase Inverter solar= with HD-Wave Technology for North America. SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE10000H-US/SE1140CH-US SE3000H-US I SE3800H-US I SE5000H-US I SE6000H-US I SE760OH-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 31111 240V 1 5000 6000 @ 240V 7600 10000 11400 VA .............................................. ................ 3300,@ 208V� , 5000 @ 208V. . ...-.... ........'.....5000..... . ... . ........ ........... Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 .VA ........-..- GII:............................. ................ 330.R208V. ................ .5000 @ 208V. ................ ................. ................. .......:... AC Output Voltage Min:Nom.-Max. ✓ - J - - - Vac ........................... ............... ................ ................ . AC Output Voltage Min:Nom:Max. ✓ ! J -....J. ., ............... .J -......J -J ' Vac . ..(211,-2 -. ").......................... ................ :. AC Fre uen Nominal .............v ................ .59.3-60-60.51d............... ................. ................. ........... .........9....�'.�.........1 .......:..... ................ ................ ................ ................. ................ ................. ............... H?..... Maximum Continuous Output Current _ 16 - 24 - - A 208V ...Maximum Continuous .t Current .... .......lfi...... .......21...... .......25....... .......3Z...... .......qZ...... ......47.5...... ....A..... Maxmum Continuous Output Current ..9240V.................................... ................ ................ ................ ................. ................ ................. .........:....... .... ....... GFDI Threshold 1 A .............................................. ...........................................................Yes................................. U01iry Monitoring,Islanding Protection, _ .-....................... ........��� Count Confi urable Thresholds INPUT Maximum DC Power @240V 4650. 5900 ,7750, 9300 11800 1550017650 W Maximum DC Power @20SV.............. ................ ......5100..,,. ,._.. •,:,,.-,_, __,,.7750, - - - Yes M. aximuminput Voltage„ .,.,.. ,,, ,,. 480 Vic, Nominal DC Input Voltage 380 400 Vdc .... ................ Maximum Input Current @240V.......... ... ..8 5......I.....10.5......I.....13.5.. ...I......16 5...... ......20....... ......Z�.......I......30.5...... ...Adc.... Max.-Input Short Circuit,Curreni..,....... ...................................45... Adc .I...................... ........................................................ ........... Reverse-Polarit Protection ,- Yes , ..................Y........................... ............................................ ........—............................ ......... ........... Ground-Fault Isolation Detection 600koknsid ft. Maximum Inverter Eff!clenry............. ......99.......I._...................._..., 99.2 CECWeighted EHiciency.................. ...........................................................99 - ............................... .... ..........I.................�..�. Nighttime Pawer Consumption <2.5 W ADDITIONALCommunication FEAES .......... .. '. I Revenue Grade Data,AN51 C """""'-"""""" 485;Ethernet,Zi Bee(o tional);Cellular o tionaq ....pport......... Interfaces.... RS;.........-..-....g.......p... . .....ular I.p.......... 12.20 .........................:........0 ptionali�1..:....................... ' .................... ..................... ............................................... .......... Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 1 STANDARD COMPLIANCE "' .. " ' . ety.. . .................... . .... UL3741,UL1741 SA,UL1699B,CSA C22. (Cdian..AC.accoM9...to. ...L.M0T.. .............. Grid Connection Standards I . ........... ..... 7,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Ran&e.... ............................3/4"minimum(14-6 ......._............- . _3/4"minimum/14:4 AWG', ........... DC Input Conduit Size/4 of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/ AWG Range. :............................. . ....... ...146 AWG- • 17.7 x 14.6 x 6.8/450 x 370 x 174 . . . 21.3 x 14.6 x 7.3/540 x 370 in/mm Dimensions with Safety Switch(HxW.... x 185 ...:........:...................:..:......:... ..................16.:,...'.....�. ................ .... .......:..................... ....:....:....................... . ........:.. Weight with Safety Switch.. 2../.1............ ..'..25;. ..... „I.. 26.2(11:9..... 38.8/17.6 , <25 ....., . , . <50 ...dBA:... Cooling. Natural Convection Natural convection ......... ................................... ................ ...............- .................. . . ..... . ... Operating Temperature Range............ .... ....... .....................13 t0+140/..25 to+6001 f-40:F/,;40Y.option)1'r.... .........-.-................ F�•C... ........................ ..... Protection Rating NEMA 3R(Inverter with Safety Swdch) UlFprotherreglonal settings please ronGct SolarEdgesdppod io Revenue is gmde To,P.wcmdeinverter p/N:SEmaH-USOmNNC2 r de-rzttng In(ormadon refer to'httpr//wwwsolaredge c6m/sitei/dehuVfies/seiemperaturederatlngnote-na.pdf I4I40ve.l.n P/N.SEwouH-USOOONNU4 I TOPSPEED ROOF ATTACHMENT DETAIL TO WOOD DECK REVISION: 1 2� NEW DETAR EACH MOUNT HAS I"OF LEVELING CAPABILITY - A 51VIZM KN1M BDP ACETO REFER TO SNAPNRACK INSTALLATION MANUAL FOR RTTOM OFFMODUL —BOTTOM OF _— HARDWARE TORQUE SPECIFICATIONS HEIGHT RANGE:3.5-4.5IN FOR ATTACHMENT SPECIFICATIONS,SEE: "SNR-DC-3DOD4 TOPSPEED,ATTACHMENT DETAIL, .. MOUNT TO WOOD DECO - .. - ROOFING MATERIAL, .. FOR MOUNT PLACEMENT SPECIFICATIONS,SEE: MODULE HEIGHIr OFF ROOF: COMP SHINGLE,TYP. °SNR-DC-30005 TOPSPEED,MOUNT PLACEMENT ON- 3Y-41/i IN -SOLARPANEL° - - BASE HEIGNr UNDER SCREW: " FOR BASIC SYSTEM INFORMATION SEE MINIMUM OECKTHICKNESS: : .600IN 7116"DEC OSS °SNR-DC-30006,TOPSPEED,SYSTEM OVERNEW ON COMP' 15/32°PLYWOOD FOR SPECIAL CASE INSTALLATIONS SEE: "SNR-DC-30007 TOPSPEED,SPECIAL 615E .. - INSTAD.ATfON" ' MIN Ii°PLYWOOD OR OSB ROOF DECK MIN J"PROTURSION OF WOOD SOREW.THROUGH DECK _ MIN U4°SCREW PROTRUSION TOPSPEED MOUNT ASSEMBLY ATTACHMENT DETAIL (X4)#14 WOOD SCREWS,S.S: ..ROOFING MATERIAL, FILLY EMBEDED INTO WOOD DECK COMP SHINGLE,TYP. - _ WOOD ROOF - _ DECKING,TYP. FILL°SPEEDSEALn CAVITIES WITH APPROPRIATE _ ROOF SEALANT TO WATERPROOF ATTACH MENT. OVERVIEW SEE INSTALLATION MANUAL FOR DETAILS ON .PROPER PLACEMENT ON COURSE o5unrun South LLC - DESIGNER: M.AFFENTRANGER "5/27/2022 DRAWING NUMBER: DESCRIPRON: DRAFTER:::-M.AFFEN RANGERSNR-DC-30004 TOPSPEED,ATTACHMENT DETAIL,MOUNT TO Solar Mounting Solutions M APPROVED BY: B.PETERSON WOOD DECK