HomeMy WebLinkAbout50581-Z ,�. TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 50581 Date: 4/24/2024 Permission is hereby granted to: Giron, Jose 1000 Bayer Rd Mattituck, NY 11952 To: install roof-mounted solar panels and energy storage system (located outdoors) to existing single-family dwelling as applied for. At premises located at: 1000 Bayer Rd, Mattituck SCTM # 473889 Sec/Block/Lot# 107.-9-29 Pursuant to application dated 3/18/2024 and approved by the Building Inspector. To expire on 10/24/2025. Fees: SOLAR PANELS $100.00 ELECTRIC $125.00 CO -ALTERATION TO DWELLING $100.00 Total: $325.00 Building Inspector "io � TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 htt s://www.sog!hqldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. -- Building Inspector: Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: —/5 OWNER(S)OF PROPERTY: Name: o5e SCTM# 1000- / Project Address: /UdU ! Ve / G /'-Aa-/� Phone#: Email; Mailing Address: ,Q � CONTACT PERSON: Name: Mailing Address: r, ,/ l / Email; � !T�'I` S `Co Phone#: �.. �,/�... ,;�� � DESIGN PROFESSIONAL INFORMATION: Name. a °t Mailing Address:/76212UX ' 12C/ CJ1 =/ ' A16 Phone#: Email: CONTRACTOR INFORMATION: Name; . Mailing Address: ,l e�(JC,� 1J �L//' � "" .. Phone#: . —r y Email: , . `^� (���`—cJ'� DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition DAMe—ration []Repair ❑Demolition Estimated Cat of Project: ❑Other Will the lot be re-graded? Dyes ❑No Will excess fill be removed from premises? Dyes ❑No 1 b i PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ONO IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): 01�uthorized Agent ❑Owner Signature of Applicant: J X e �L��-- C �- �- Date: STATE OF NEW YORK) SS: COUNTY OF ,e C ? being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the "- (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set foI`th4o;tl` � p ilication file therewith. i 4 Sworn before me this /S-.O'day of ZIT�e�e� s� � � t,�"�L�fR aAU COUNT 5fary Public 81 s� �Rry L�`� •fir �� (Where the applicant is not the owner) I, ) 5 G ra't residing at G do hereby authorize Mc ,, , to apply on my behalf to the Town of Southold Building Department for approval as described herein. lem Owner's Signature Date Print Owner's Name 2 suff0k COMAY DOW,Of �jr lilt FN�\ Lill, �Yi i:: il Q ill I I »q'q:q« L kpivsfl m GH 140 Rsila& ofovW)14 noM 02024 r 1 � r m a Suffolk 'County DepE of Labor, Lioensin , & C+ rtsu,,n,r Affairs RYAS i ER ELECTRICAL LICENSE Name SAMY MoUNAS Business Name SUNRUN INSTA LATI( N SERVICES �.. e F,rwies that ;ht; u"d t� autry t o a� SOO 33878 d To, � Ab�.a�°.� �,9 �,��f"a�8k, License Number ME- 155tied 10/01/2003 EXp i res: 10i0112025 SUNRINC-02 TWANP CERTIFICATE OF LIABILITY INSURANCE [:DATF9Eiv202s Y) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements PRODUCER License#OC36861 ,cv Walter Tanner Atliant Insurance Services,Inc. 560 Mission St 6th FI �o,E*� .. . _ d___ San Francisco,CA 94105 HtNsSS _ Br_Qa)liant.com WWalter Tann e._ _ INsu9 R,.�,j;yalll,eton in, uran a_C rrlpa'Ipa __ 5 7 i ......... INSURED- -. ... ......, -� ...- .._� ... ..-.....��.._- INSURER,B p_Zurich American Insurance COnI,�,.a�......,_1.6535 ..., Sunrun Installation Services,Inc INsuRER,C:American Zurich Insurance Com any 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER p San Luis Obispo,CA 93401 INSURER E INSURER F: COVERAGES CERTFICATE NUMBER: FtEVI,SIOI�I NUMBEFk, THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, S SHOWN MAY HAVE REDUCED BY PAID CLAIMS. TYPE of INSURANCE POLICIES.LIMIT �y aw E BEEN �.,�_ ., INSR EXCLUSIONS AND CONDITIONS OF SUCH ADDL suBR POLICY EFF POLICY EXP POLICY NUMBER LIMBS A X COMMERCIAL GENERAL LIABILITY „EACH..CICCLIRR.ENCE,_5 m„00 2,000,0 _ _ OCCUR 10/1/2023 10/112024 DAMAGE TO RENTED r , CLAIMS-MADE X... R MKLV5E �.._ _..5,�0 MED EX�Any one persons _ w _ ....... r X'N L AGGREGATE T APPLIES.. PEtsoN s nDy�N�,uRv 2 000,01111 _" �II—... V 2,000 000 GEPER GENERAL AGGREGATE � P Per ProjectA - 5,000 000 z _ X.. POLICYOTTIER,Retention:'�21I� IIII�II LOCPRDDucs-cD 9 rga�nc� � �000®(Mi10 B AUTOMOBILE LIABILITY........ r COMBINED SINGLE LIMIT .. ..,,.,. 2,OOIl,OIIO Ix ANY AUTO SAP614287702 10/1/2023 10/1/2024 BO,DIL,YINJUI Y_(P!rper an n,n,,,.,,.,,,,, OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per,.aaciden �,m,_,w,,,, �� ��ry �q,� a rut AM hGE IAURT"OS ONLY _ A 6�I abir OPERTa. 1,OI)O OOq98%6M: X Coll,:Not Covered r UMBRELLA LIAR OCCUR EAQ DCCURRENP,E__„„, - ..., EXCESS LIAB CLAIMS-MADE _ q_gRE�GATE DED mP COMPENSATION WC614287602 10/1/2023 10/1/2024 k_PTEARTLTE.. JHRH 1,000,06 C WORKERS COMPENSATION YIN X 1,000,000 AND EMPLOYERS LABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE E L EACkI ACCIpi:.NT, w„ OFFICER/MEMBER EXCLUDED' NIA -- (Mandatory in NH) E L DISEAqE F AAhI OYE -- _ If yes,describe under 1000000 DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT DESCRIPTION Of OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Addltlonal Remarks Schedule,may be attached If more space Is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Evidence of insurance CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Route 25 Southold,NY 11971 AUTHORIZED REPRESENTATIVE jp ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 225 Bush Street Suite 1400 1c.NYS Unemployment Insurance Employer Registration Number of San Francisco,CA 94104 Insured 50-86426 4 Work Location of Insured (Only required if coverage is specifically limited to certain locations in New York State,i.e., 1 d.Federal Employer Identification Number of Insured or Social Security a Wrap-Up Policy) Number 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage(Entity 3a.Name of Insurance Carrier Being Listed as the Certificate Holder) AMERICAN ZURICH INSURANCE COMPANY Town of Southold Town Hall Annex Building 3b.Policy Number of Entity Listed in Box"1 a" 54375 Route 25 P.O.Box 1179 ' WC 6142876-02 Southold,NY 11971 3c.Policy effective period 10/01/2023 to 10/01/2024 3d.The Proprietor,Partners or Executive Officers are ❑ included.(Only check box if all partners/officers included) 0 all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is Issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Mark AN (Print name of authorized representative or licensed agent of insurance carrier) Approved by: i�4119, /&G 10-01-2023 (Signature) (Date) Title: VP/Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (415)946-7500 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov YORK workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Sunrun Installation Services Inc. 202 Commerce Dr., Ste. 7 Moorestown, NJ 08057 1c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) The Prudential Insurance Company of America Town of Southold 53095 Route 25 3b.Policy Number of Entity Listed in Box 1 a Southold, NY 11971 CG-52830-NY 3c.Policy Effective Period 1/1/2024 To 1213112024 4. Policy provides the following benefits: Q A.Both disability and Paid Family Leave benefits. ❑ B.Disability benefits only. ❑ C. Paid Family Leave benefits only. 5. Policy covers: A.All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS disability and/or Paid Family Leave benefits insurance coverage as described above, Date Signed January 02, 2024 By . (Signature of insurance carrier's authorized representative or NYS licensed insurance agent of that insurance carrier) Telephone Number 215-658-7318 Name and Title Carolynn Smith -VP Contracts IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200, Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(only if sox 48,4C or 513 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and Paid Family Leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) III DBIIII11°°°1°°°°1°°1°°°1°°°1°°°IIIII 120.1 (12-21) d MIGHTY ENGINEERING:CO. .... .. . .... .. . March 14,2024 RE: CERTIFICATION.LETTER Project Address: JOSE GIRON RESIDENCE 1000 BAYER RD MATTITUCK,NY;11952 Design Criteria: -Applicable Codes=2020 NYSRC,2018 IRC/IBC/IEBC,ASCE 7-16 and 2018 NDS -Risk Category=II -Wind Speed=128.mph,Exposure Category B,Partially/Fully Enclosed Method Ground Snow'Load=.25-psf ROOF AR-01:2 x 6 @.24"OC,Roof DL=7 psf,Roof LUSL= 19 psf(Non-PV),Roof LUSL=13.8 psf(PV) -ROOF AR-02:2 x 6.@ 24"OC,Roof.DL.=7 psf,Roof LUSL=19.psf(Non-PV),Roof LUSL=.13.5.psf(PV) -ROOF AR-03:2 x 6 @ 24"OC,Roof DL 7 psf,Roof LUSL=15.psf(Non-PV),Roof LUSL=.8 psf(PV) To Whom It May:Concern, :A structural evaluation of loading was conducted for the above address based on the design criteria listed.above. Existing roof.structural framing'has been reviewed:for additional loading due to'ih§tallation of PV Solar System on the roof..The structural review applies to:the sections of roof that is directly supporting the-so la r PV:system. Based on.this evaluation, I certify that the alteration to:the existing structure by installation of the PV system meets the prescriptive compliance requirements of the-applicable existing.building and/or.new building provisions adopted/referenced above. . Additionally,the PV module assembly including attachment hardware has been reviewed to be in accordance.with.the manufacturer's. .. . :-. specifications and to meet'and/or exceed the requirements set forth by the referenced codes. Sincerely, NILOFNEW Digitally signed by, ... HAKy�����. Manouchehr . _. 1-lakharnaneshi .0 ,oaee2 Date'2024 .314 Ross�oNa.,r.. 09:48:35-04 00.. Mighty En ineerin 'Co i 1708 Roxborou h Rd:Charlotte,NC 28211 980 6K9776 info@rhight en ineerin co.com. t- g Y g� g.. g �.� ) � � Y g'. g Pg l of 11 ... ... ... ... SHEET INDEX SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION SYSTEM.SIZE:1080OW DC,7600W AC: .: ALL WORK SHALL COMPLY WITH 2O20 NEW YORK STATE RESIDENTIAL CODE PV-1.0 COVER SHEET MODULES:"(27)HANWHA"Q-CELLS:Q.PEAK DUO BLK . WITH 2018IRC/IBC/IEBC,:MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS ML-G10+/T 400 .. ... AND INSTALLATION,INSTRUCTIONS. PV-2.0" SITE PLAN '-INVERTERS:(1)SOLAREDGE TECHNOLOGIES: PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV 3.0 LAYOUT SE760OH-USSN RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 " •ENERGY STORAGE SYSTEM:(1)TESLA:POWERWALL, PV5.0 SIGNAGE •:PHOTOVOLTAIC SYSTEM IS UNGROUNDED:NO:CONDUCTORS ARE SOLIDLY 13.5KWh,5KW INVERTER OUTPUT,LITHIUM-ION BATTERY GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. P��OF NEw y (WEIGHT:251.3LB EACH) BACKUP:GATEWAY:(1)200A'TESLA POWERWALL CONTROL MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. a * oV 7y PANEL .. .' •IN ONF AND IS UNDER 3 � •NEW UB E IN VERTER C ORMS TO LISTED UL 1741. W�p0 AMP S -PANEL TO B STALLED: .. .... ..:. S T .. 2 .. ... •RACKING CONFORM 0 AND IS LISTED UNDER UL 2703. ,2 103982. SNAPNRACK RACKING SYSTEMS;IN COMBINATION WITH TYPE I,OR TYPE II" MODULES,ARE:CLASS A FIRE RATED. OFESSION . •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND AL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC690.12(1).L �IgltaySigned: CONSTRUCTION FOREMAN O PLACE CONDUIT RUN STRUCT REMANT CECOND "PER690.31(G)."" ":: man.OuchehrF: W •ARRAY DC CONDUCTORS ARE SIZED FOR'DERATED CURRENT. a a I71a ne5 � 12.18AMPS MODULE SHORT CIRCUIT.CURRENT. Date: 2024.03:14 15.23 AMPS DERATED SHORT.CIRCUIT CURRENT.[690.8(A)&690.8.(B)]. 27_O/I�oOt ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE `t :. .. .. :WITH R327.4 .. .. ESS SUBJECT TO VEHICLE IMPACT WILL BE PROTECTED BYAN APPROVED BARRIER IN ACCORDANCE1IVITIi.'fHE 2020 NEVIIYORK STATE,RESIDENTIAL CODE 'SECTION R327:9 AND THE 2020 FIRE CODE OF NE YORK STATE SECTION 312.2, •ROOMS AND AREAS WHERE ENERGY STORAGE SYSTEMS ARE INSTALLEDsunrun.. SHALL BE PROTECTED ON THE SYSTEM SIDE BY NO LESS THAN 5/8 INCH TYPE X "' ""' GYPSUM BOARD OR EQUIVALENT,INSTALLED ON THE'WALLS AND CEILING OF THE ROOM OR AREA IN ACCORDANCE WITH THE 2020 NEW YORK STATE " RESIDENTIAL CODE SECTION R327 6 ....R 00825-ME•ENERGY STORAGE:SYSTEM CONFORMS TO AND IS LISTED UNDER:UL 9540. ABBREVIATIONS:. VICINITY MAP •ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING ncnu NoueRacuRono,wEs euRv,urnsso A AMPERE ROUTINE MAINTENANCE.SYSTEM VOLTAGE:IN ACCORDANCE.WITH NEC 706.30 . ' ::� ;;. ... ::� .::' ..� P� C \a� .. . { e AND EXCEPTION 1 NEC 706.30.(A). AC ALTERNATING CURRENT. .v`-'''°""""?- �a,,'-y+�� >F`•• ADDITIONAL DISCONNECTING:MEANS SHALL BE INSTALLED WHERE ENERGY. CUSTOMER RESIDENCE:" AFC.: ARC FAULT CIRCUIT INTERUPTER , STORAGE DEVICE INPUT AND OUTPUT TERMINALS ARE MORE THAN 5 FT FROM JOSE"GIRON o AZIM AZIMUTH ,OR WHERE THE CIRCUITS FROM THESE TERMINALS 1000 BAYER RD,MATTITUCK, ✓,;", .a`'. CONNECTED EQUIPMENT . Q ? j PASS THROUGH A WALL OR PARTITION PER 7067(E). NY,.11952 COMP" COMPDSRION - Y --{�' 'LISTED,COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP m .. Ip / g bc' DIRECT CURRENT "' / CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DO T INC t ES NO LODE ANY TEL 631)295-6838 (E). Ems-wid ; ; ~' : ADDITIONAL OUTLETS-OR DEVICES PER NEC 210.12 D.: ..' _ THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR APN:10DO-107-0D 09-00 " ESS ENERGY STORAGE SYSTEM,',,,, „'+"" �, ... - PROJECT NUMBER:-02 . .... 9-000 s' GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION . MSP MAIN SERVICE PANEL ,; °1. - EQUIPMENT CONNECTED TO THE SYSTEM PER NEC ARTICLE 710.15(A).: - 216R-0OOGIRO (N): NEW /p •ALL PASS-THROUGH CONDUCTORS MUST COMPLY.WITH NEC 312.8 "" ESIGNER: (415 2D e .... .q ..1 _ .. .. R.f � D )580•fi9 x3 PRE-FAB PRE-FABRICATED `4 a .. .. .. .. .. .. '. .. .' "' '' ''' j" ' JULIETFRANCISCO PSF POUNDS PER SQUARE F00T ''+ e SHEETT� PV PHOTOVOLTAIC: i--,a.: j))) .... ... .. .... - .... .... ... - RSD.'. RAPID SHUTDOWN DEVICE :.-- � ; . .. . . . . . ..- . . OVER SHEET REV: Al TL TRANSFORMERLESS. - ... ... 3/14/2024 Uz';< . '.;9'F a'` ` : voLrs ... .. ... .,� ,�,:. ,. ® .. V.. - .. - PAGE W. WATTS ... ... ARRAY TRUE :MAG PV AREA SITE PLAN'-SCALE=3132'=1'4" SITE PLAN-SCALE=1132"=1'-0"' PITCH AZIM 'AZIM (SQFT) ® AR-01 27° 203°. 215° 190.2.. ROOF PATHWAYS AR-02 28° 21' :33' 169.1' ::(V.TYP) AR-03 45 -262° 214 211.4 AMP BGTS Jw. SE a $.;, .. - g: .. .... ... .... .... . .... .:'y.;:�.� :i': .... .... .... ... .. ... .. .. .. .. .: .: y FIRE SETBACKS (18'TYP) ' ( ) R 2 N A RAYAR-0 * o y Q N PL. ( DRIVEWAY ` vL03982 ... .. ).. ... E RESIDENCE NOTE:ESS SHALL BE INSTALLED 3FT FROM DOORS AND W. WINDOWS IN ACCORDANCE WITH R327 4... sunru m: (N)ARRAY AR-03 ... — r E Y' l 0082 (N)ARRAY AR-01 — 5 M E n7GVYfWOUE ROq(RORD,FAK WE FNONE BOS.fiE0.5CBT I=— -- - - CUSTOMER RESIDENCE:" .... .... JOSE,GIRON 1000 BAYER RD,MATTITUCK, ROOF PATHWAYS NY,"11952 (3'TYP) -_ :.. TEL.(631)295-0638 APN:1000-107-00-09-00-029-000 .PROJECT NUMBER: . 216R-000GIRO . SOUR LEGEND � ❑�ELECTRIC VEHICLE MICROGRID DEVICE : GROUNDING 20 SM SUNRUN METER:::. AC DISCONNECT(S) EV MD SCALEr NTS- SUPPLY EQUPMENT INTERCONNECTVIC ELECTRODE MoouLEs DESIGNER'• JULIE NOTE:NOiALLrrEMSINLECEND' DC, + - ENERGY STORAGE F—1 INTERIOR EQUIPMENT* SHEET WILL WILL APPEAR IN SITE PLAN: F1M DEDICATED.PV METER DC DISCONNECT(S)" �F METER ADAPTER " ❑SYSTEM ❑ L J SHOWN AS DASHED sNRMOUNr "SITE PLAN " SNR NIOUNTdSNIRT SE. SERVICE ENTRANCE rSP SUB-PANEL .. INV INVERTER(S) .. AM ACREL METER BI BACKUP INTERFACE. COMMUNICATION IF BACKUP GATEWAY O. O. O O WIRES O REV:Al 3/14/2024 MP MAIN PANEL LC PV LOAD CENTER SEM SOLAREDGE METER CB IQ COMBINER BOX B_P BACKUP LOADS PANEL POWERWALL ENERGY GP GENERATION PANEL ." PAGE PV-2.O O — -STORAGE SYSTEM(ESS) O . . ... ... ... ... ... ... ... ... ROOF INFO FRAMING INFO..' " ATTACHMENT INFORMATION.' " DESIGN CRITERIA Name Type ,Height Type : Detail" "' Configuration MAXF Max OC Max Landscape Max Landscape Max Portrait Max Portrait DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang ' OC Spacing Overhang NOW LOAD:25 PS WIND SPEED: RL UNIVERSAL,SPEEDSEAL TRACK ON AR01 COMP SHINGLE-RLU' '2-Story 2X6 RAFTERS 14'-8" 24" 6"-0"' 2'-4'" 4.-0" ' 2.7 0" STAGGERED F GUST. - .. COMP,SEE DETAIL SNR-DC-00436 28 MPH 3 SEC UST .RL UNIVERSAL,.SPEEDSEAL TRACK ON " 16. IN.EMBEDMENT AR-02 'COMP SHINGLE=RLU 2-Story. 2X6 RAFTERS 14'=8" COMP,SEE DETAIL SNR-DC-00436 24" 5 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED RLU NIVERSAL,SPEEDSEAL TRACK ON AR-03 COMP SHINGLE-RLU 1=Story. 2X6 RAFTERS 15'-1" 24" 6'-0" 2'-4" 4"-0" 2'-0" STAGGERED COMP,SEE DETAIL SNR-DC.00436 _ . ... -D1-AR-01-SCALE:1/8"=1'-0 D2-AR-02-SCALE:1/8"=1'-0" ':AZIM:203° m m. AZIM:21° PITCH:27°.... PITCH:28 q. _.. .. ... _. OF NEW,yo .. .. .. .. .. .. .. .. .. .. ... .. .. q .. .. :. 1V-5. .. —6'TYP— .. .. .. .. .. ..:. ..:. I, . . :. n tj .... ... 2''7" '��FESSION q m . : :suns n : 133-AR-03=SCALE:1/6"'=1'-0" 5M AZIM:202°.. . •.. ... ... •. '177 CrWr1AGUE ROG(R . PHONE BBSSC054B1 PITCH:45° .. Paxesaee.zou 2,2„ .. .. .. .. CUST MER RESIDENCE' INSTALLERS SHALL NOTIFY ENGINEER OF ANY JOSE.GIRON : ... R ,POTENTIAL STRUCTURAL ISSUES:OBSERVED 1000 BAYER D,MATTITUCK PRIOR TO PROCEEDING W/INSTALLATION. NY,1 1952 _'V TYP- ... ... . IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" -rIEL.(631)266-iillili' = BOUNDARY REGION OF ANY ROOF PLANE _ .: .: " _ q APN:1000.107-00 09-00-029-000 1T5 EDGES(EXCEPT VALLEYS),THEN ' _ �AT NEED TO BE ADDED AND PROJECT NUMBER: ..: ."..: OVERHANG REDUCED WITHIN THE 12" 216R-0OOGIRO - ..: BOUNDARY REGION ONLY AS FOLLOWS: . .. .: .: DESIGNER: ) '•ALLOWABLE ATTACHMENT SPACING. 415 590-09 x3 INDICATED ON PLANS TO BE REDUCED BY 50%. '' '' JULIET FRANCISCO "ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE SHEET AT SPACING INDICATED ON PLANS. LAYOUT, 26-511 6r2'r— 34 'PAGE E PV.3.0 . ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. ... . .SINGLE PHASE .: 100A .. .... SUB PANEL ... .... ... .. . ' 'SERVICE .. ... ... METER#. .�.. NEW .' ® PSEGU 883118 . Btl 100A MAIN;' ';'UTILITY ...ACC#:9616OD6205: ... . BREAKER.. GRID 04s0EfA1RRF?R " .. .. - . ..(E)RELOCATED .. , ':.SERVICE ENTRANCE- NON-BACKUP .. .. .. .. .. .. .. . .: CONDUCTORS O. .:.. LOADS �� .... { .... ' . .... ' . .... .... ... .... . .... . .... .... .... .. .. �� .. fN)206A BACKUP .. .. - ... GATEWAY IMTH / O .. ... .. 100A m Of.NEW .. .. .. ..2 .. .. :(N)WA ESS .. .. .. .. .. '.. '- .. .. �ABREAKQ`epK K4 v/�y� ...OPPOERATSITE END:'.... .. CT .... . .... . (1)ENERGY STORAGE SYSTEM.. OF AR:�� �/` . ..:. ..:. ..: .. — A EM W (N)40A. ... ... .:SERVICE ENTRANCE ... PV BREAKER AT 1 ... .. .. .- .. .. .. OPPOSITE END.� 24 MAX AC CURRENT N A 3R .. CONDUCTORS.: " OF 6USBAR _ (1)SOLAR PV CURRENT a 106286`w(`a EXISTING TRANSFORMER TRANSFORMER.... , .... (BN�OCKABLE SOLAREDGE TECHNOLOGIES: .... .... ... .. .. pTOfEsS'O`r� .... r BREAKER; � � �� SE750OH-USSN" . ..:. I. (END FED_):. .-:. :. NVERTER NWHA QCE .(E)FACILITY ,,,,� AC TTI F+/ •L ML-G70HT 400LLS - t4IIy _ . ".3•�. DISCONNECT 2 ��R E�����.�1 � �O�PEAK DUG BLK::. Digi Si�9 ned . • EXISTING NOTE:TOTAL GENERATION BACKFEED=70.ODA MODULE E ' .. .. .. ... .. LOADS ram" A�.N 76J00`WA .. ... / ((27TMODULES .. .. PV 125A USEDFORINTERCONNECTIONCALCULATIONS ,Wy BABAK ER .. .. IRS PANEL .. ..MAIN .. ... .... ...'',,,, SQUARED ,' LOAD RATED DC DISH ONNECT � (N1)EERIEFS OF(14)OPTIMIZERS. RED I . .... .. .: .: l e DU RB WITH AFCI,RAPID UTDOWN ", 60 R DGE POWER OPTIMIZERS I Vl .. .. .. .. ANT S440 ..: ..:. ..:. 1 0240VAC .... .. . COMPLIANT Date: 2024.03.14 CONDUIT SCHEDULE.. ... ... .. ... ... .. .. .. .. .. .. so .. .. # CONDUIT. ':, CONDUCTOR : ;. NEUTRAL':. 'GROUND "' .. .. .. .. ' 14138:21 00 1".... NONE .. (4).10 AWG PV WIRE'... NONE. (1)13 AWG HARE COPPER, . .. . " ... ' .. - ........ .... 2..: .1'PVCOR:EQUN.. (4).10AWGTHHN/THWN-2.: NONE' (1)10AWGTHHNRHWI-2' ... ... .. 3 '1"PVC OR EQUN. (2)B AWG THHN/THWN-2 (1)10 AWG THHNRH... (1)B AWG THHN/THMM-2' sung n '4 1"PVC OR EQUN. (2)10 AWG THHIT HWN-2 (1)10 AWG THHN/MN-2 (1)8 AWG THHN/TFIWN-2 5 1-PVC OR EQUN. _(2)3 AWG THHWiHWN-2 (1)3AWG-rHHWTHWN-2' (1)8 AWG THHN/fHWN-2 " 00825-ME •. ... .... .. .... .... DA SfBURY N llM 171.LANf1A(kIE ROCKR O,WE . RiDl�805.5®.5487 CUSTOMER RESIDENCE'. ' ... .... .... JOSE GIRON :'.... MODULE CHARACTERISTICS R 1000 BA R D, HANWHA Q-CELLS::Q.PEAK DUO BLK NY,11952 ML-G10+/T 400: 400-W V:S440 OPTIMIZER CHARACTERISTICS: ":. " " TEL.(631)296.6838 OPEN CIRCUIT VOLTAGE:: 45.09 V'MIN INPUT VOLTAGE: 8 VDC APN:1000-107-00-09=00-029-000 MAX POWER VOLTAGE: 38.09 V MAX INPUT VOLTAGE: .: 60 VDC SHORT.CIRCUIT CURRENT:" 12.18A. MAX INPUT 14.5ADC PROJECT NUMBER: .. .. .. .. .. .. .. .. .. .. .. .. 21BR-ODOGIRO MAX OUTPUT:CURRENT: "":15ADC .. :. .. . ... ... ..:. .. 20 . - DESIGNER: (415)580-69 BX3 JULIETFRANCISCO SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 10800 W SHEET :SYSTEM OPEN CIRCUIT VOLTAGE... 14 V.... .... ' SYSTEM OPERATING VOLTAGE: 400 V ELECTRICAL. MAX.ALLOWABLE.DC VOLTAGE: .. 480 V.:. . 'SYSTEM OPERATING CURRENT: 27'A REV:Al 3H412024 SYSTEM'SHORT CIRCUIT CURRENT: " . :30 A " " " " " PAGE ":. .. .... _. ... .. ... ... ... ... ... .. .. .. .INVERTERI .. .. • • • • DISCONNECTNOTES AND SPECIFICATIONS:... •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2D17 ARTICLE. PHOTOVOLTAIC SYSTEM 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY'SECTION 690,OR' 777 K HAZARD • aao 1 IF REQUESTED BY THE LOCAL'AHJ. COMBINER PANEL ...SIGNSAND LABELS SHALL ADEQUATELY.WARN OF HAZARDS USING EFFECTIVE. CURRENT:MAXIMUM CIRCUIT 30: •1 LINE LOAD .: ". DO NOT"ADD LOADS WORDS,COLORS AND SYMBOLS. RGIZED IN O LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING: LABEL LOCATION: •• METHOD AND SHALL NOT BE HAND WRITTEN. SITION • •• 15. :-.LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT "'PHOTOVOLTAIC AC COMBINER OFIIIIIIIIIIIIIF "" .APPLICABLE)'.' INVOLVED. .. .. .. - LABEL LOCATION: .. ..:PER CODE(S):CEC 2019:705.12(B)(2)(3j(c), LABEL LOCATION: :, ... ..:. •SIGNS AND LABELS.SHALL COMPLY WITH ANSI Z535.42011,PRODUCT SAFETY INVERTER(S),ACR]C DISCONNECT(S), 'NEC 2017:705.12(B)(2)(3)(c) INVERTER(S),DC DISCONNECT(S). SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. - - "' AC COMBINER PANEL OF APPLICABLE). "' "' "' .:. :."PER CODE(S):CEC 20t9:690.53,NEC'2017:690.53 .::' ::" .:: •DO NOT COVER EXISTING MANUFACTURER LABELS; PER CODE(S):CEC 2019:690.13(B);NEC - - ��� THREE POWER SUPPLY .. SOURCES:UTILITY GRID, .:. ..:. ..:. .. ... .. .... ..:. ..:. .... ... PowER SOURCEOUIPUTCONNECTION BATTERY AND PV SOLAR. ' '" ELECTRIC SYSTEM OVERCURRENT DEVICE LABEL LOCATION: .LABEL LOCATION:.. ..'UTILITY SERVICE METER AND MAIN .. - .... .. .... .. . .... _ -... .... _ •`�OF NEW- .. .ADJACENT TO PV BREAKER OF :SERVICE PANEL..: ... ... •tQ-. \( KA .APPLICABLE). . ..:' PER CODE(S):CEC 2019:706.11 3 .. _ .. _ .... c,' 0p .V�•4'O`-/. ... ... PER CODE(S):CEC 2019: ... 705.11(A)O 706.11 017:705.12(B)(3), .,. ... .. ... .. ... .. .. .. .. * �Q' 705.12(B)(2)(3)(b),NEC 2017: .. 705.12(B)(2)(3)(b). .. .. .. .. .. .. r 2 106286 � • �op'�OFESSIONP�� FOR • A' PV SYSTEM q "LABEL LOCATION: - - - BUILDING :SUPPLIED BY UTILITY - - - "- INSTALLED WITHIN TOF RAPID SHUTDOWN - ^ -.su.n:run.:. I'1 SWITCH PER CODE(S):CEC 2019:690.56(C)(3),NEC - .. 4„ GRID ND PHOTOVOLTAIC .. .. " 2017:890.56(C)(3),IFC 2012:605.11.1,IFC 2D16: � �;" 120a.5.3,,CFC2019:120a.5.3•; SYSTEM . .... .... 00825-ME . ' • ■ • • • , ■�I�� ��D MH. AIED P■-N �_. M.15,2033� RAD,NESTBURY.N111590 CUSTOMER RESIDENCE:. LABEL LOCATION:. .. .... .. .. .... .... .. .. .. "INTERIOR AND EXTERIOR OC CONDUIT EVERY 1 O FT, 0 BAYE , AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3". TURN RAPID SHUTDOWN .... NY,.11952 R RD 1 ,MATTITUCK . ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. SWITCH TO THE"OFF' PER CODE(S):CEC 2019:690.31(G)(3),690.31(G)(4),. '^'° ® T.EL.(631)296-i836. "' w. _ w NEC 2017:690.31(G)(3),690.31(G)(4),IFC 2012: POSRION TO SHUT DOWN .: ' sas.11.1.a. PV SYSTEM AND REDUCE .. .. .. APN:1000 107-00-09-00-029-000 SHOCK HAZARD IN THE PROJECT NUMBER: PHOTOVOLTAIC 1 • ARRAY. . pv SYSTEM 216E-0OOGIRO . .. ..:. .. "DISCONNECT- ••• '• • •' i 11 • oR DESIGNER`. (415)5605920 ex3 ,EXTERIOR GND FLOOR:'' ' .. ... ... ... ... ... .. .. ... .. ... .MAIN PANEL- . .. ...NOMINAL OPERATING AC VOLTAGE: 240 VAC .. .. INT ERIOR BASEMENT JULIET FRANCISCO ,LABEL LOCATION:, .: .: _ .: .. ,; SHEET .. . LABEL LOCATION: ' LABEL LOCATION: . .... ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE POINT OF INTERCONNECTION' S IGNAGE AC DISCONNECT( SYSTEM POINT OF;INTERCONNECTION.,,: ,DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ''..: (PER CODE NEC690.56(B);NEC705.10,225.37,230.2(E)). PER CODE(S):CEC 2019;690.54,NEC 2017:690.54,NEC 2014:S90,54,NEC ARE CONNECTED., -2011:690.54 - PER CODE(S):CEC 2D19:690.56(C)(1)(a),NEC 2017: REV:Al 3/14/2024 0)(1)(a) s90.ss( E PAG PV.5'.0 - poweredbv" .. DUO . ealAi�� .1iy:. • ac,du . t TOP mmb Pv .. i Orielilty Ta.tad .. . .:113.40032587 .. . ELECTRICITY' HQig lower oos D h'O eT h'e�yield per surface area,I er BOS t tg i 'power.classes,and an.efficlency rate of up to 19.9%. q q INNOVATIVE ALL-WEATHER TECHNOLOGY' . with,excellent: .timal yields whatever the weather w' � ant ...low=light and temperature behaviour. _ G. ENDURIN. HIGH PERFORMANCE Lon term 'eld securit with Anti LID Tectinoio y . .. . . . . .. 9- Y gY,Anti PID .. V .::'.:.Technology', TM...:. gy,Hot-Spot Protect and Traceable Quality Tra.Q.. ' . . . . .. . . EXTREME WEATHER RATING High-tech alum'n;um alloy frame,certlfled.for 7/ high show(5400Pa)and wihd loads(4000Pa). . .. A . _. O RELIABLE:INV TMENT Inclusive.l2-year product warranty and'25;year linear periforman,_'e warranty- . . W. STATE'OF.THE ART-MODULE TECHNOLOGY Q.ANTUM D.UO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. APT test conditions according to IEC/TS 62804-1:201^,•method B t-1500V,168h) See data sheet on rear for further inlormatidn. THE IDEAL SOLUTION FOR:: ... . 'Rooftop arrays on Rooftop arrays on . . .. .. . . residential bmldin s.. Commercial and g industrial bui dingsq. ' . .... Engineered in Germany . . . . . . .. . . . MECHANICAL SPECIFICATION :. 11 ormst 66.3 in x 39.4 in x 1.26in(inc)uding.freme) (1685mm'x;1000mm x 32rritn) ears wa 867! - - �.-.-....- ae as t9a9o.*I: U9•pflSmm)' Height 41.21bs(18.Jkg)" ' "" . .. . . . . ..Front Cover 0.13in(3.2mm)thermally pre-stressed glass with . . . .. anti-reflection technology ,yam Back'Cover Composite film Frame ". ." Black anodized aluminum . . Cell 6 x 20 monperys[Elline; .ANTUM solar half cells" •v„ a9•nao9.e- Junction Box 2.09-3.98In x 1.26-2.361n x 0,59-0.71in mob°., ua«-a (53r101mm x 32.60mm x 15-18mm),IP67,with bypass diodes.... Cable 4mm2Solar,cable;,(+)>_43,3in(1100mm),(-)>_43.3in(il00rtiin) e.a.°,9.a.: .. 'i.u,,oy.aoro�.w.r .. . . . . .. Connector.... Stdubh MC4;Henwhe.Q CELLS HQC4,Amphenol UTX,.:. Renhe 05-6,Toiigling TL CableOlS,JMTHY:JMBOI;IP.68 or .� 7r.rnmm, DUM.D�'!ia ,nr: . Friends PV2e;IP67.. .. •:vT-�Q--lb'av-ia an„u. .. :.: .99as•d.s :. ELECTRICAL CHARACTERISTICS... POWER CLASS is :: :. :. 315 :: :. 320 :326 Y `330. ...:.MINIMUM PERFORMANCE.AT•STANDARDTEST.CONDITJON.S,STC!(POWER TOCERANCE+S W/-0 W) Power at MPP' PO,.. (W) 3.16. 320:. :. 325.: 330 E'. ShorlCircuit Current' I, ]AJ: 9.99 10.04 L0.10 10.15_ - 'Open Circuit Voltage' : ' Vim. (VJ" 39.84 40.10 40.36 40.62' . .. . . . . ...9 . . . . . c Current at MPP. I,•,,,. [A) 9.51 ::9.56 9.61::' 9.67 Voltage of MPP V,/o, .. (V] 33:14 :33.4Z: 33.81:. 34.14 E(liciencyt q {H,); e18.7 e19.0 >_19.3 i19.6 MtNIMU. M PERFORMANCE AT NORMAL OPERATJNG CONDITIONS,NMOT-1 POweratMPP ": pw, [W) 235.9 239:6. ' ' '" MA:.:'.: 247.1 " C Short Circuit Current: IS [AI 8.65 8.09 814. ,E Open Circuit Voltage Vo [V} 37.56 :..'.: 3781 38.06 :.:38.31 .E .•Curren(at MPP 1,,,,, [A]. 7.48 7.52 7.57 7.61 Voltag_,at MPP. VF.w .. IV) 31.53. 31.85. . . 32.17. . " 32.48 rMeasurement tolerancesP,;"o't3%,1;-;V�ct5%atSTC:l000W/m';26m2'C,AM1.5 according toMC'60904-3•'800W/m2,.NMOT,spectrumAM1.5 'Q CELLS PERFORMANCE WARRANTY. " "PERFORMANCE AT.LOW IRRADIANCE.. . . . no T--:-_:',�'..__. i u ;, _.••,...e'.w.w.�y, I, At least 98%of nom nai power during w W ..+...i.,..,...• first acThereaftermax ..0.54% . 40 °' - degradatioh per year,At least 931 �%' : .r noL--`-----°- w a of nominal power up to 10 years;At . ...:_-;__._., least85%ofnominalpowerupto .. y oAll date within ir'easuiement tolerant- i ':. :. i. „ es.Full warranties in accordance with raD 410 000 a' -the wartantytermsof the 0CELLS z, f u n sales orgja6isation of your respective o" .. u: ;. counlrK :.:'.: .. ,� �s"„ �. k. reaas TypicalModOlegerlormenceunderlowirradiancec nda nsin Q q«a.,aem:wror,r 0":.i=Ns'ra«�0,. ...:. :. :. .. :. comptulson to$TC conditions(25°C 1000Wlm'). 9 TEMPERATURE COEFFICIENTS . o. Temperature Coefficieritofhc :;'d VVY1: -+0.04:: Temperature CooflicientofVa (%/K); -0.27 Tern perature:Coefficient of P,,,':' y I%/tiJ -D,25 Normal Module Operating Temperature NMOT I'F) 109t5.4(43't3'C) ..... 0 " PROPERTIES FOR.SYSTEMS DESIGN v,eximum S stem V' - "i y Oltage V' [V] ..'SOOO(IEC)/IOOO(t1L);. Safety,Class Maximum Series Fuse Rating (AbC) ::" 20 Fire Rating based on,ANsl%UL 1703 C(IEC)/TYPE 2.(UL) M_ai.Design:Load,Push/Pull' "1I15s/161 75(3600Re)/55.(2667Pa) Permitted ModOle Temperature : -40°F up to+185'F o . . . . . . on Continuous Duty*Max.Test Load;Push/"Pull' " (Ibs/ft7J 1'13(5400Pa)/84(4000Pa). 40'C.upto*85'C) 'See InstaFation Manual .. QUALIFICATIONS.AND CERTIFICATES .... .... PACKAGING INFORMATION UL t703,VDE Oual,ty Tested.CE-compliant,IEC 61215:2016,IEC 517 0.201G'. Number of Moduti+s Per Pailot . .. 32 u ArpP,,a'°on Class tl,U.S.Patent No.9,893.215(solar cells) §: • Number of Pallets per 53'Trailer '.. 30 . .Number of Pallets.per 40'HC-Container .. P BVE'N C--trs 'PalletDimensions(l.x,WxHj: 69.3 .!i1 .3?/j6Arn(1760x1150x1190.rim) s[ o Pallet Weight 1415Ib§(642kg) �.. . :Note:Installation instructions must be loilowed.Seethe inslallahon and operating manual or contactouf technical service department for further information on approved installation and use olilnsproduct. , HrnwhaQ CELLS Aen'orlea Inc. '' .. ... .. .. www.q-cetls.us Spectrum Center.Drive,:SuRe:2400.Irvine,CA 92618.USA I f Ek:+1 949 748 59 961 MAt L.mquby@us.q-cells.com I W ER .... soar - • • l Single Phase Inverter with HD-Wave Technology • for. North Amer:ica': SE3000H-US/SE3800H-US/SE5000H=US/ SE6000H-US/SE7600H-US/SE10000H-US/SE1140OH-US i _ solar-..= & : solar-.r_ v�w�� ••• � .. :. . .. h. ♦ •.OR _• .. _ .. .. .. :. I � I Optimized installation with H.D.-Wave technology Specifically designed to work with power optimizers :. Record-breaking efficiency AW Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 201:4.and 2017,per article 690.11 and 690.12 UL1741.SA certified;for CPUC Rule 21 grid compliance.,. i Extremely small High reliability without any electrolytic-capacitors Built-in module-level monitoring II�11111111' :. — Outdoor'and indoor installation wave -- Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.51 accuracy).- - re g us www:so a e. Single Phase Inverter solar - with HD-Wave Technology for North America. E3000H-US./.SE3800H-US/SE5000H-US/ SE6000H-US/SE7600H77U.S/.SE10000H'=US/.SE1140OH-US --- --- . - ... ... . .. ... ... . .. SE3000H-6S' .SE380OH-U5 1 SESOOOH US SE6000H-US SE760OH-US SE10000H-US: .SE1140OH-US OUTPUT 3800 @ 240V' 6000 0 240V: :. Rated AC Power Output 3000 -' 5000 7600 10000. 11400 :.. VA:. ...•.......... 3300,@;208V, 5000 P 208V, Max.At Power Output..... • 3000 --.. 3800 @ 240V' 5000'.. 6000 @ 240V 7600 10000 11400 VA ::....: 3300(la 208Y. .......::....... .5000 @,208V. .::.::.............................................. .............. .... ......... .. AC Output Voltage Min._Nom:Max. _ �183,-208-229)................ ... ✓ �'.. :..:: . :.::... Vac .......... AC Output Voltage Min.-Nom:Max. - ✓ ✓ ✓ %.: ✓ ✓ ✓ vac.. ..( q 24p;264)........................... AC Fre uen Nominal 59.3-60-60.512i Hz .. .. ....... . Maximum Continuous Output Current :.: 48Y........................:.............. ..........:..... . 16..,.. 24 A Maximum Continuous Output Current :.... ..... ................ ..:..:......:.... 240V 12.5 "'16: 21 "':25' 32 42 " 47.5 A FDIT..:::.......................:.:...::: ...........:. GFDI Threshold' — .... .. ........ ....A..... Utility Monitoring,Isfanding Protection, Country Confi urable Tfi�esholds "' Yes INPUT�� . .. Maximum DC Power @240V 55 1 4650 5900 7750 9300: 11800 00 17650 W 1 _ ............... ...... Maximum DC Power @2... . 5100 7750 ' Transformer-less,Ungrounded Yes .................. ... Maximum In ut Volta a 480 Vdc P.,.......�....::.::. ................ ............... Nominal DC Input Voltage —380 400 Vdc. Maximum In ut Current 208V 9 13.5: P.......................::..::. ..... .......... .............:.. ................ ................. .. ............. ................. ...... ...... . . Maximum In' ut Current 240V 8.5 10.5 13.5 ,. 16.5 20 27 30.5 Adc ... P.: 4°?.. ..... ..... ............... .. ... Max.Input Short CircuitCurrent 45...... ... Adc....... ................. .... Reverse-Polari Protection. . Yes ,...,.................................. ... ................ ............. ............... .................. Ground-Fault Isolation Detection. :. 600kaaSensitivit ........ ................ . y................::.::.._::.:..:..... Maximum Inverter Efficiency..........::. ......99....... .....:.:::.:::.......................:.:...:::...99:?........... ... CEC Weighted Efficiency::.:.::....... ::..:::..:. :........ .. 99 .............. ........:....:..... .../..... ... .. .. .... . Nighttime Power CIbhsumptibn <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,Ethernet,ZigBee(optional),Cellular(optional) .................... Revenue Grade Data.ANSI,C12.2........ ....... : .. .. .... ....... .... Optfonal1�1.............. .... . ...................... .. . .. Rapid Shutdown-NEC 2014 and 2017 Autorhatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22;2;Canadian AFCI according to T.LL.M-07 Grid Connection Standards IEEE1547 Rule .. Rule 14(HI) Emissions ... ... .. FCC Part 15 Class B :.INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4 minimum/14-6 AWG 3/4"minimum/14;4AWG DC Input Conduit Size/#of Strings/ ': 3/4'minimum/1-2 strings/14 6 AWG :. 3/4 minimum/1-3 strings/ AWGRang?..::........... 14-6 AWG .................. ..................................................................................... ................... . 5. ....... .. 213x14 6x7.3 540x370 Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8./450 x370 x 174 x 185 in/mm . .. Weight with Safety Switch 22/.10............I•-25.1/11:4 I...........26.2/11:9 38.8/17.6::......... .Ib/,kg..... . Noise ... .. <25 <50..... dBA .................. ... :......................... Cooliri : .Natural Convection Natural Convection g.:.:..:............................. .................. Operating Temperature Range.......:.... :.................. .. -13to+140/.:25.to,+6013i(:40•F�.:40`Coption)I4i.....:....:.....................,............... ....................... Protection Rating NEMA 3R(Inverter with Safety Switch) ill For other regional settings please contact SolarEdge support . ... ... . .. ... ... .. iZl Revenue grade Inverter P/N:5EncwtH-US000NNC2: isl For power de-radng Information refer to:hitps.//www.solaredge.com/sftes/default/files/se-temperature-denting-note-na.pd(, _ ial-40 versfon,P/N:SExapcH-USOOONNU4 0 RoHS i o SolarEdge Technologies,Inc,All rights reserved. logo,OPTIMIZED BY SOLAREDGE .. { S w • MIA, S' ? System designed with All parts fit in a box for easy maximum versatility for any 'ry logistics arrays including staggered Drop-in features make the install process intuitive and fast - Simple design allows system to 11- 1' be installed by single installer Listed to UL Standard 2703 for on the roof UL Grounding/Bonding and Fire Classification SnapNrack RL Universal highest-is designed to provide the fastest, most intuitive install experience for residential roofs. The direct mount system features four basic components for easy material management. Features incredible flexibility with a single Universal mounts that fit module heights from 32 -.40 mm and the • . of Flash =Track with:Patented Umbrella Technology Single Umbrella lag screw secures flashin.g.and flash track.to.roof in one complete action •:Umbrella technolo rovides weather roofin with a lon 0)00 gY p p 9. .. � g- :lasting mechanical, seal .... . ... ...... . .. .......... ....... Flash trac is.designed for maximum versatility with 6 inches:of North-South adjus.tability for all Mounts _. .. . ... . .... . Mounts ..... . . Single mount use. :at:a ocationson array Extreme time saver by eliminating link interference through the flexibility. of the Mount to change:orientation Features crock=in channel nut desi Le gn for easy attachment to Flash-Track • Slotted.ri.s.er provides leveling.for easy.hei.ght adjustments........ .......... .... .... .... . . .. Lin s . . . j Simple design.provides mounting platform between two to.four..... . modules ... • Clamps onto top of:modules securing them in place.while providing I► . . .. .. row=to=row bonding: ... . . .. .Next row of:modules easilyslides.into place:as with the Mounts. Skirt • Easily locks to bottom.of module mounts.and.links for clean aesthetics ..... . Ensures a strong structure for leveling and alignment-of first row of modules :Skirt.length is compatible,with both portrait landscape module orientations - - -I V9,: . .. .......... .. ..... . . ......... . . .......... Quality. Innovative . Superior. SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources • improve overall installationquality and . • 2019 • .r Mounting Solutions, .. .. q. DESCRIPTION:: DRAWN BY: shapWac SNAPNRACK RL UNIVERSAL, MOUNT mwatkins :, : ... . ... . . .:Solar Mounting Solutions • " "REVISION: ..PART NUMBER(S): :. .. .. .. ... 5MARK 9410 .. ' .. .. .. 9 PHONE( -6 .. ET STREET,29TH FLOOR:SqN FRANCISCO,CA 5 USA A q E A15)580-5900 FAX(415)580 902 242-02155 THE INFOWATION IN TNIS DRAWNG IS CONRDENTIgLAND PROPRIETARY.ANY .. .. .. REPRODUCTION,DISQOSURE,OR USE THEREOF IS PROHIBITEDNATHOUTIHE WRITTEN CONSENT OF SUNRUN SOUTH- .. .. .. .. 1 .5 .. .. 9 :3 8 1. q a . ::2:. :. : ::' �. cm) . 6 .. ... . . . . . . . . . . PARTS LIST ITEM QTY :. •DESCRIPTION.: 1 1 SNAPNRACK,.RL UNIVERSAL, RISER, MILL 2 1 SNAPNRACK,:RL UNIVERSAL; LEVELER, MILL::.." 3 1-: SNAPNRACK, RL UNIVERSAL, MOUNT BOTTOM, MILL .4 1 SNAPNRACK, RL UNIVERSAL, MOUNT TOP, BLACK. 5 1 SNAPNRACK,: RL UNIVERSAL;'BONDING CLIP..' ' : . 6 1. SNAPNRACK, DROP IN/ROCK IN CHANNEL NUT 7 1 ' BOLT; FLANGE, 5/16IN-18 X 3/4IN,:CLEAR SS 8 '_' ':.1 BOLT, FLANGE, SERRATED; 5/16I.N-18 X 1IN; SS :':. " 9 1 SNAPNRACK, RL UNIVERSAL, MOUNT.SPRING; S9 10 1 BOLT, FLANGE, SERRATED, 3/8IN-1:6.X 2�3/4IN, 1/2IN TRIM HEAD, 1.2IN THREAD, BLACK, SS. MATERIALS: 6000 SERIES ALUMINUM, STAINLESS.STEEL OPTIONS: ... . . DESIGN LOAD (LBS): 623 UP, 6.74 DOWN, 505 SIDE ULTIMATE LOAD (LBS):.' N/A " TORQUE SPECIFICATION::: .12'.LB-FT, CERTIFICATION:. UL 27.03, FILE E359313 . WEIGHT LBS 0.73::.. : :.' DESCRIP:TIOW DRAWN BY: . ....... ... + SNAPNRACK; RL UNIVERSAL, MOUNT mwatkins. snap :::Solar. Mountin Solutions REVISION: 9 PART NUMBER(S): • 95 MAR 9410 5 MARKET STREET,29TH FLOOR.SAN FRANCISCO,CA 5 USA A PHONE 415)5808.0 •FAX(415)SBO fi902 242-02155 ... YME INFORMATION IN THIS pRAWTNG IS CONFlDENTIAL AND PROPRIETARY.ANY .. .. .. .. .. .. .. .. .. :REPRODUCTION,DISCLOSURE,OR USE THEREOFIS PROHISR-THOUTTHE WRITTENCO .. .. .. .. .. .. .. .. O:.. NSENT FSUNRUN StlVfH LLC.� 1.50::.. w. . 3..41 1:.50 2.35 ►I 4. j. 1:5.0 1.55 66 2.00 q. 1.24 SLOT �y. 263 1::5 0 --� ALL.DIMENSIONS IN INCHES .. : POWERWALL Tesla Powerwall is a fully-integrated AC battery system for residential or light commeYcial use..Its rechargeable:lithium-ion battery pack provides energy storage for solar_self=consumption, . .. time-based control; and backup. Powerwall's electrical interface provides a simple connection to any home or building. Its Yevolutibhary.compact design achieves market-leading energy density and is,easy to install, enabling: : . owners to quickly realize the benefits of reliable','clean.power. q. PERFORMANCE SPECIFICATIONS :MECHANICAL:SPECIFICATIONS : =:. . —� AC Voltage;(Nominal) 120/240 V Dimensions' 1150 mm x 753 mm x 147 mm: — (45.3in'x'29.6inx5.75in) ' Fee&In Type 'Split.Phase Weight' 114 kg(251.3 Ibs) Grid Frequency-— 60 Hz' — --- -- -- -- --- - _ _ Mounting options Floor or wall mount Tot al.Erieigy' 14 kWh — f 3Dimensions and weight differ slightly iP mane acture d before March 2019: :. Usable Energy 13.S kWh Contact Tesla:foradditional information. Real Power,max continuous: 5 kW(charge and discharge) : :'753 mm 1:4 mm (29.6 in : (5.751h) Real Power,peak(16s,off-grid%backup), 7-kW(charge and discharge) Apparent Power,max continuous: .5.8 kVA(charge and discharge) Apparent Power,peak :as 7.2 kVA(charge and discharge): '. V:o M. .w (10s,off-grid/backup) II . Load Stait'Capability : ;;; 88 A LRA for each:Powerwall Maximum Supply Fault Current : : '10 kA1150 inm' Maximum Output Fault Current: 32 4 5.3 in) <4 Overcurrent•Protection Device 30 A Imbalance:for Split-Phase Loads : 16o% Power Factor Output Range.: +/-'1.0:adj'stable Power Factor Range(full-rated power)__ +./-:0.85' Internal Battery DC Voltage 50 V . ---: . :ENVIRONMENTAL-SPECIFICATIONS Round Trip Efficiency's "' Warranty.. 10 years = ... - -4°F to 122°F)Operating Temperature 20°C to 50°C:( 'Values provided for 25°C(770F),33 ISW ct arge/discharge power.. Recommended Temperature 0°C:to300C(32°F to 86°F) 2AC to battery to AC,at beginning of life: --- .. ... ".'=Operating Humidity(RH) Up to 100%,coridensing'. Stbrag e Conditions -20°C to 300t.(-4°F to 86°F) COMPLIANCE INFORMATION Up to 95%RH,non-condensing,' Certifications UL 1642;UL 1741,UL 1973, _ Sfate of Energy(SoE):25%initial UL 9540.IEEE 1547.UN 38.3 Maximum Elevation 3000 m(9843:ft) -- Grid Connection Worldwide Compatibility Environment Indoor and outdoor rated Emissions; ;. :FCC Part 15 Class B,ICES 003: Enclosure Type. NEMA:3R -- -- — — Environmental ROHS Directive;2011/65/EU' Ingress Rating 67(Battery&.Power Electronics) .. .. IP56(Wiring Compartment) Seismic AC156,IEEE 693-2005(high) Wet Location Rating: Yes. .:Meets the unit level performance - Fire Testing.. Noise Level @ 1m < 40 dBA at 30°C(86°F) criteria of UL 9540A T 5 L_ n THLA.COM/ENERGY TYPICAL SYSTEM' LAYOUTS WHOLE HOME BACKUP 'Optional; \ l / .. .. Solar O i Solar inverter Main panel Backup Gateway. .. Utility meter. Grid including service disconnect ... T=5 L r'1 O_ I� Powerwall. -whole home backup .. PARTIAL HOME BACKUP -------------- Optional Solar, O Solar inverter '-------------------------- Sub panel Backup Gatewiay Main panel Utility meter Grid .. . Powerwall Backup loads . :.. Home loads 5 L er NA-BACKUP-202-1-"11-15 TESLA.COM/ENERGY