Loading...
HomeMy WebLinkAbout50195-Z �p'1$1 OI y Town of Southold 2/4/2024 P.O.Box 1179 a t 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 44930 Date: 2/4/2024 THIS CERTIFIES that the building ALTERATION Location of Property: 1075 Main St,Greenport SCTM#: 473889 Sec/Block/Lot: 34.-1-10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/4/2019 pursuant to which Building Permit No. 50195 dated 1/9/2024 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alterations to bathrooms, central air conditioning and window replacements to existing apartment building as applied for. The certificate is issued to Victorian Bay LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 50195 1/25/2024 PLUMBERS CERTIFICATION DATED (jori a Signature �o�Lam_ TOWN OF SOUTHOLD suFent,��o BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE oy • o� } SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50195 Date: 1/9/2024 Permission is hereby granted to: Victorian Bay LLC 8485 Main Rd East Marion, NY 11939 To: make alterations (bathrooms) to an existing building as applied for. Amended 11/6/2019 for 17 in kind window replacements. Replaces BP44289 At premises located at: 1075 Main St, Greenport SCTM # 473889 Sec/Block/Lot# 34.-1-10 Pursuant to application dated 10/4/2019 and approved by the Building Inspector. To expire on 7/10/2025. Fees: PERMIT RENEWAL $139.00 ELECTRIC $100.00 Total: $239.00 Building Inspector ��o�g�FFn TOWN OF SOUTHOLD BUILDING DEPARTMENT rn a TOWN CLERK'S OFFICE SOUTHOLD', NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44289 Date: 10/15/2019 Permission is hereby granted to: HSBC Bank USA NA c/o Ocwen Loan Servicing LLC 1661 Worthington Rd Ste 100 West Palm Beach, FL 33409 To: make alterations (bathrooms).to an existing;building as applied for. Amended 11/6/2019 for 17 in kind window replacements'. At premises located at: 1075 Main St,.Greenport SCTM.# 473889 Sec/Block/Lot# 34.-1-10 Pursuant to application dated 10/4/2019. and approved by the Building Inspector. To expire on 4/15/2021. Fees: SINGLE FAMILY DWELLING_ADDITION OR ALTERATION $228.00 CO -ALTERATION TO DWELLING $50.00 Total: $278.00 Buildi ns c 4�SUFEQj�co TOWN OF SOUTHOLD �� ay BUILDING DEPARTMENT TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) ' Permit#: 44289 Date: 10/15/2019 Permission is hereby granted to: HSBC Bank USA NA c/o Ocwen Loan Servicing LLC 1661 Worthington Rd Ste 100 West Palm Beach, FL 33409 To:, make alterations (bathrooms).to an existing building as applied for. At premises located at: 1075 Main St, Greenport SCTM #473889 Sec/Block/Lot# 34.-1-10' Pursuant to application dated 10/4/2019 and approved by the Building Inspector. To expire on 4/15/2021. Fees: SINGLE FAMILY DWELLIN(!--ADDITION OR ALTERATION $228.00 CO -ALTE ON O DWELL G $50.00 Tot 1: $278.00 Building Inspector Form No.6 TOWN OF SOUTHOL.D BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept_ of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 19S7) non-conforming uses, or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling.$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. C�C��pC� '1 l 2 0� New Construction: Old or Pre-existing Building: (check one) Location of Property � �rJ ©�T M N 10 ST V_C_1E_T C-c— N r n \ House No. Street Hamlet Owner or Owners of Property: En u L Suffolk County Tax Map No 1000, Section 14 Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: • Planning Board Approval: Request for: Temporary ert icate Final Certificate: (check one) Fee Submitted:S Ap licant Signature SO(/r�o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 �1�� �_`�0 sear.devlinC&-town.southold.ny.us 4UNT`I, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Victorian Bay LLC Address: 1075 Main Rd aka 1215 city:Greenport st: NY zip: 11944 Building Permit#: 50195 section: 34 Block: 1 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Homeowner License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor X Hot Tub Addition Surrey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 2 Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures Smoke Detectors Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 8 Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: Notes: HVAC Inspector Signature: Date: January 25, 2024 S.Devlin-Cert Electrical Compliance Form OF SOUIyOlo �� —l 5_ - f 0 7,S�_ -- �' {' TOWN OF SOUTHOLD BUILDING DEPT. c� - Qurm?�'' 631-765-1802 r�1 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PR�EQC/O [ ] RENTAL REMARKS: i IV Me, kW 4 � DATE INSPECTOR hO�aOF SOGlHp6 * # TOWN OF SOUTHOLD BUILDING DEPT. `ycou 631-765-1802 © f INSPECTION [ ]' FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL AMMLA f [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �I 6ttkyou Co'C✓ DATE INSPECTOR 1, of LR i I,nl 3a f t f ra, L-7J 0 r 2 n a w ) 2ol hA ash AK% �o-� 1 ^ G �k ALA } qb W-1 6 �, { 4K 'M Y I Z.t, Mak, n . Sy, moe+5P # A—Xiit ..e r ,, ' w y ` �R FIELD INSPECTION REPORT •DATE COMMENTS (� Q° to FOUNDATION (1ST) vA� ------------------------------------ �C FOUNDATION (2ND) z . o v ROUGH FRAMING& �t PLUMBING 1 O r INSULATION PER N.Y. y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS d r r z x - zt, d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 ( Survey Southoldtownny.gov PERMIT NO. [ Check 400 + T Septic Form + (� N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20 Single&Separate Truss Identification Form Stone-Water Assessment Form Contact: Approved ,20 Mail to: Disapproved a/c Phone: Expiration 20 0 + M i c[oI L) • ' Building Inspe r i = • OCT 4 20�9 APPLICATION FOR BUILDING PERMIT - • Date ©G+n bCC , 20191 -`''' ' INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) TO ��X q, m4Vlon N� (Mailing address of applicant) 11 ry 3 State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder V 1 ( hylan P)a,3 - 0 w n�e Name of owner of premises V i uA py l L A y L L C (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and tft`1e.6f corporate officer) Builders License No.=-'.;,-,.<; Plumbers License,N0. Electricians License No. Other Trade's License No. 1. Location 4 land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section M Block Lot i D Subdivision Filed Map No. Lot 2. State existing use and occupancy of pre ses and intended use and occupancy of proposed construction: a. Existing use and occupancy y �Lll>1��y b. .Intended use and occupancy 3. Nature of wor (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work P \44 ioig G-� 9A ✓ S (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling u its Number of dwelling units on each floor �— If garage, number of cars /vim 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing strictures, if any: Front Rear Depth Height Number of Storiesi 2 Z Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase 14 200 Name of Former Owner L.G E 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO 13. Will lot be re-graded? YES NO ✓ Will excess fill be removed from premises?YES NO ``14. Names of Owner of premises Ann oyi% J `�S AddressFo ?)U-f q I3 E Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES V NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMI-PlZ MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO y * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) S410, yApn i qcl being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the [Aeyy,6" ni nt Publicl,Sta e� yow (Contractor,Agent, Corporate Officer, etc.) NO ®uallfled in sultoik county mission Exuirros A0 I4,2 of said owner or owners, and is duly authorized to perform or have performed the sal ,mission to make and file-this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sw r to before me th' �1 day of DC=:�. 20 Notary Public ignature of Applicant SUFFO�,�.0 BUILDING DEPARTMENT- Electrical Inspector OG TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 "4 p�� Telephone (631) 765-1802 - FAX (631) 765-9502 lamesh(c-southoldtownny aov- seand(cDsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: a Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Vi cT6 k l A tJ S A. L L(. Address: 1 U 2►S �k t �' � Cross Street: o y+h t2 0 q A Phone No.: (a 6 - Z o I -3 51�O Bldg.Permit#: 5f) ( q 5 email: dkc-if' e-e- iz alavc-, Tax Map District: 1000 Section: 3 Ll Block: I Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Kiwi 5 PI1-r Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO Rough In Final Do you need a Temp Certificate?: YES �O Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service0 Fire ReconnectO Flood Reconnect[-]Service ReconnectOUnderground[]Overhead # Underground Laterals 1 2 M H Frame Pole Work done on Service? Y ON Additional Information: PAYMENT DUE WITH APPLICATION �.c ��3 c0 In i rA i Hill e , c c eS S i ro I e �Q-� d r�rG C.VIA �.�%. I0 5MVEY OF PROPERLY SITUATE: (9REEWORT TOM: SOMOLD SUFFOLK COUNTY, NY SURVEYED 01-11-01 AMENDED 01-2&-01 %FFOLK COUNTY TAX 1000-34-1-10 CERTIFIED TO: PAUL LOE5 LAND N.-,:H !Ell�; t;F ul N63012'10,m 15000, -------------- ---------- -- ---------------- --- - z t r 2 STORY F -IE Ls RAI HOUSE .3 Lo ce NOTES: ` H \ ' MONUMENT FOUND 150.W S63028'10"W LA'Arl 0= AREA= 14,448 SF OR 034 ACRES JOHN C. EHLERS LAND SURVEYOR 6 FAST MAIN STREET N.Y.S.LIC.NO.50202 GRAPHIC SCALE 1.=20' RIVERFM%D,N.Y.11901 369-8288F.369-8287 REF=%kHpsc-crNd\PROS%01-2I9.pro SUPERVISOR'S OFFICE TOWN CLERK'S OFFICE 16 South Street Main BUILDING DEPARTMENT Southold,Street Greenport, N. Y. N. Y. . Tel. Greenport 7-0550 Tel. Southold 5-3783 TOWN OF SOUTHOLD SUFFOLK COUNTY, N. Y. . BUILDING PNSPECTOR'S. OFFICE 307 npprf, street 6reenport, N. Y. CERTIFICATE OF OCCUPANCY Tel. Greenport 7-0101 J No. I`D O Date N,.IL I:j:: I9� THIS CERTIFIES that the building located at Street, Map No.. ; Block No. """ , Lot No.. in the Town of Southold, conforms substantially to the approved plans and specifications heretofore filed in this ' office with Application for Building Permit dated ^ 1%M; pursuant to which Building Permit No. 1. , dated 14r_c, was issued, and conforms to all of the require. ments of the applicable provisions of the aw. The occupancy for which this certificate is'issued is This certificate is issued to of the aforesaid building. Cam, vv l BWIding Inspector (The Certificate of Occupancy will be issued only after the Building Inspector is convinced of the completion of the construction in compliance with the 'Multiple Residence Law and with other laws, ordinances or regulations affecting the promises, and in conformity with the approved plans and specifications.) - 3rd Floor Space (Neva Layout) N 2W _ 30"x 30" Skylight i pitched ceiling 15" x 24" 81 Drastically pitched ceiling in this section LZ Window W E • Door --•—�-�: j 30"x 30" Skylight Closet in pitched ceiling jSta 11 ir Qto2n / 27 1/4"x 34"Window 30"x 30" 16 Skylight S in pitched ceiling that opens to a right angle CcjVpLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND-QQW99QN94�F— A P P R 0 VIE,D ."S N Q"I"E D A IS&I_Za�, 2.P. T E: v NIT i�j MfEES )R THE- AM "0 :A ; :v- , *l. FOLLOWiNG VSP�-c F i. ,VVo FR* QUIRED OUNDA I ION FOR POURED C 0 E 71 E 2. ROUGH - FRAi'vIiNG 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMIPLIETEL FOR C-0. ALL CONSTRUCT ION! SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NO?' RESPONSIBLE FOR DESIGN OR CONS I RUC TION ERRORS. (J� 2nJ Moot' ot-1,4W) bul UIL �n ex s� N I its Mash GrecnPOc� � A � �ti 11"4 f lq t emen4 17- A Andersen Andersen Windows-Abbreviated Quote Report Andersen •w Project Name:ace contracting new window quote Quote#:.a*fWGft Print Date: 10/15/2019 Quote Date: 10/15/2019 iQ Version: 19.1 Dealer RIVERHEAD BUILDING SUPPLY Customer.,1 - AND R EN TRADE ID FOR RIVERHEAD BUILDING BUILD SMARTER.BUILD BETTER. Billing 1-600�7t1-3650 Address: W W W.RBSCORP.COM Phone: Fax; Sales Rep: qkii+Irf M Contact: Trade ID: o60055 Promotion Code: Item Oty ItenvSize(Operation) Location Unit Price EXL Price 0002 2 WDH2852E(AA) $ I1111111�s Adfiw iRO Size o2'101/8"WX5'4718"H' UnitSao=2'95/8"WX5'47/8^H I 400 Series lv I Unit.Equal Sash,White/Clear Pine,High Performance Low-E4 Glass(Each Sash),Traditional,Stone,1 Sash Locks Equal Sash,Insect Screen.White Zone:North-Central Maxod from Extorkr U-Factor:0.29. SHGC;0,31, ENERGY STARO Cortifed;Yes 0003 3 WDH3452E(AA) $ %mums +w� ROSIze=3'6118"WX-T47/8"H JJnitSize=3'55/8"WX.74718"H 400 Series Unit,Equal Sash,white/Clear Pine,High Performance Low-E4 Glass(Each Sash),Traditional,Stone,1 Sash Locks Equal Sash,Insect Screen,White Zeno:North-Central Vtowwd from EK10rtor U-Factor 0.29, SHGC:0.31, ENERGY STAR®CertlOod:Yes Quote Print Date: 10/15/2019 Page 1 Of 4 iQ Version: 19.1 �15NfA1N "T Gr&U11V0KT � S VD k 5 N0\ - 4 2019 � 1 Item city kern Size Soporatiort) Location Unit Price Ext Price 0004 1 WDH18210(AA) $ $ ROSizLm1'10118"Wx3'07/e"H Unit Size=1'9518"Wx3'07/8"H 400 Series Unit,Equal Sash,White/Clear Pine,High Performance Low-E4 Glass(Each Sash),Traditional,Stone,1 Sash Locks p------ Equal Sash,Insect Screen,White Zone:North-Central Vlowad from EYtor-.br - U+actor:0.29, SHGC:0,31, ENERGY STAR®Cortifled:Yes 0005 1 WDH2652E(AA) S 4blb S 41110M 1ROSfze=2781/8"Wx5'47/8"H Unit Size=2'7518"Wx5'47/8"H 400 Series Unit Equal Sash,Whito/Clear Pine,High Performance Low-E4 Glass(Each Sash),Traditional,Stone,1 Sash Locks ►�,(.. Equal Sash,Insect Screen,White Zone:North-Central VAawod from Extorlor U-Factor.0.29, SHGC:0.31, ENERGY STAR®Cortifiod:Yes • ~ Yfi 3 ( j 0006 3 WDH2104SE(AA) S AIIII,py11011g 40800 « I! ROSize=3'0118"Wx4'87/8"H UnitS1m=2'115/8"Wx4'87B"H 400 Series II Unit,Equal Sash,White/Clear Pine,High Performance Low•E4 Glass(Each Sash),Traditional,Stone,1 Sash Locks Equal Sash,Insect Screen,White Zone:North-Central vlowod from E=tanor• U•Faclor:0.29. SHGC:0.31. ENERGY STAR®CoRifiod:Yes Quote i►: dilow Print Date: 1 0/1 51201 9 Page 20p 4 iQ Version: 19.1 r • s i Item Qty Item Size(Operation) Location Unit Price Ext.Price OD07 7 WDIi21052E(AA) g 'e aMr�m�s ROS1zeo3'O1X-Wx5'47/8"H Unit Size=2'115/8"Wx5'47/8"H 400 Series Unit,Equal Sash,White/Clear Pine,High Performance Low-£4 Glass(Each Sash),Traditional,Stone,1 Sash Locks p Equal Sash,Insect Screen,White Zone:North-Central vlw ad from Exmrfor U•Factor:0.29. SHGC:0,31. ENERGY STARS Cortitled:Yes Subtotal .� Customer Signature Total Load Factor Tax(8.625%) Grand Total Dealer Signature —All graphics viewed from the exterior Rough opening dimensions are minimums and moy need to be increased to allow for use of building wraps or ilashings or sill panning or brackets or fasteners or other items. ® Ask to see If all of the products you purchase can be upgraded to be ENERGY STARS certified. ~ This Image Indicates that the product selected Is corti0o41n the US ENERGY STARS climate zone that you have soloeted.tu , Date is eurronta:or"2oi9.rniu data may ahonpo over umo duo to onoolno product ehvgoa or updatod toll roWla or roguIromoncn.Rodnoa tar a slzw uro spudmlod by NPRC bri=unp and=01catlon.Raunga moy vary dopording on tho Lco of tomporodglam or dfrarant arcio opgonz or gtasc for high aglludm Mt Noba Is a roglsiorod trademark of Ingersoll Rand Idx:, Project Comments: Quote#: daiiiiiiii& Print Date: 1011 M019 Page 30t 4 IQ verslcn: 19.1 o a f mrrsUaw WIL ELECTRIC at Pr get NAMO! 1216 MAIN STKF Project Number:, 34 Comment: 4 ZONES 1 CONDENSER l . a i1 L i MITSUBISHI ELECTRIC US, Inc. Quantities Model Descriation Price .4 PAC-YT53CRAU-J Simple MA controller 1 MXZ-8C60NA-U1 R41OA MXZ Series Outdoor Unit 2 PEAD A18AA7 Ceiling concealed type(ducted) Indoor Unit 2 PEAD-Al2AA7 Ceiliing concealed type(ducted)Indoor Unit 1 PAC-MKA51 BC Bran.ch Box Reff-rigerant P M ate ria is Pipe size =TotalfLength(feety Number of Bends 1/4 90 12 1/2 90 12 3/8 10 2 3/4 1.0 2 antra l ized System - 1' NO Piping Di graE-n Image ( Design View), PAC-MKA51 EC ?:$ 1 314 y g PEAR-A18AA7 114 Ed A(11 APARMENT 1 €a t PEA -A1�;7 100,1(2) ��} N rr 12 f/APARMENT 2 - n i!a; 1i2 PEAR;�1tA7 - _. R'A 13(APARMENT 3 y_ 114 1 1!2 P EAD-Al2A,A7 30.03 tf•AMIAPARMERT 4 FR.., 16 59Rtlom15.3, R!• .'Room,14,:17511 I:•'•':•Kit4h \\ r7l Room 19,275 ft' •' .;c:. r —1J:; N1T�230�•_ ySR-260' .�j ................ d PtI t� b f Bath 1 8 '140 B rt ,! SR-120 > orth 8T-120. Bath 2 Be3braom 2 FZItt��p1�0 140 Dinl6d 1. I I T 60 cma nh { ST-130 -•�. SR•170, 140 Kiteherr5,ePARR 2 1 D Gloaot 'SR1150 � � � t-3►Qf-10 '�` RR-130 R'27� Drawn: Approved: Date: t Job Number: SUBMITTAL DATA: 61 + MITSUBISHI • MULTI-ZONE Job Name: System Reference: Date: A'f:�OI�II��III IIII, � NII� 111� i) ( FEATURES • Variable speed INVERTER-driven compressor • Branch box for simplified piping and installation flexibility • Up:to 8'indoor units connectable(six[6]if a PLA-EA7 is connected).. . . • Optional base pan heater • Quiet outdoor unit operation as low as 58 dB(A) • _High pressure protection • Compressor thermal protection • Compressor overcurrenf detection. • Fan motor overheating/voltage protection • Up to 98%of rated heating capacity at 170F and 84%of rated heating capacity.at 5°F(non-ducted, condition dependent) • Energy;Star®certified (non-ducted) Specifications are subject to change without,notice. Copyright 0'2017 Mitsubishi•Electric US,Inc. SPEC I FICATIONS MXZ-8C60NA Model number Outdoor unit MXZwKWNA Indoor Ducted' Cooling*1 Maximum Capacity Btu/h. 60,000 60,000. 60,000 Rated Capacity Btu/h 60,000 60,000 60,000 Minimum Capacity Btu/h 6,000 6,000 6,000 Maximum Power Input W 4,800 5,525 6,250 Rated Power Input W 4,800 5,525 6,250 Power Factor % - - - Heating at 47* F*2 Maximum Capacity Btu/h. . 66,000 66,000. . 66,000 Rated'Capacity Btu/h 66,000 66,000 66,000 Minimunn Capacity Btu/h 7,200 7,200 7,200 Maximum Power Input W 4,870 4,810 4,750 Rated Power Input W., 4,870 4,810 4,750 Power Factor % - - - Heating at 17' F*3 Maximum Capacity Btu/h 65,000 61,500 58;000 Rated Capacity Btu/h 41,500 410000. 40;500 Maximum.Power Input W 9,525. 8,810 8,095 Rated Power Input W 4,860 4,810 4,750 Heating at 5° F*4 Maximum Capacity Btu/h 57,000 49,500 42,000 Maximum Power.lnput W 8,350 8,200 8,050 Efficiency SEER 17.40 16.30 15.10 EER*1 12.50 11.05 9.60 HSPF(IV) 10.50 10.25 10.00 COP at 470 F*2 3.40 3.40. . 3.40 COP at 170'F*3 2.50 . 2.50 2.50 ENERGY STAR®Certified Yes Electrical Voltage, Phase, Frequency 208/230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187-253 --------- ---- Voltage: Indoor-Outdoor,"S1=S2 V AC. 208V/230 Voltage: Indoor-Outdoor, S2-S3 V DC 24 Voltage: Indoor-Remote controller V DC 12 Recommended Fuse/Breaker Size A 50 Recommended.Wire Size(Indoor- AWG 16 Outdoor) Outdoor unit MCA A 46' Specifications are subject to change without.notice. Copyright©2017 Mitsubishi Electric US,Inc. SPECIFICATIONS: . I ' Model nu mber Outdoor unit M)(Z 8C60NA Indoor Ducted Fan Motor Full Load Amperage A - Fan Motor,Output W 0.2+.0.2. Airflow Rate CFM 4879 Refrigerant Control Linear Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Plate Fin Coil Sound Pressure Level, Cooling*1 dB(A) 58 Sound Pressure Level., Heating*2 dB(A) 59 Compressor Type Hermetic Compressor Model ANB66FFZMT Compressor Motor Output kW 4.2 Compressor Rated Load Amps A- - ---- -------- ---- ----- ------ - Compressor Locked Rotor Amps A - Compressor Oil:Type//Charge oz. FV50S//78 External Finish Color Munsell 3Y 7.8/ 1.1 Base Pan Heater Optional (PAC-SJ2.OBH-E) Unit Dimensions W: In. 41-11/32[1,050] [mm] D: In. 13+1 (330+25] [mm] H: In: . . 52-11/16[1,338] [mm] Package Dimensions W: In. 42-15116 [1,090] [mm] D: In. 17-11/16.[450] [mm] H: In. 56-1/4 (1,4281 [mm] Unit Weight Lb&[kg] 309[140] Package Weight Lbs.[kg] 333[151] Outdoor unit operating Cooling Intake Air Temp:(Maximum:/ OF 115 DB/23* DB temperature.range Minimum) Heating Intake Air Temp(Maximum/ OF 70 DB L-4 DB Minimum) Thermal Lock-out/Re-start Temperatures OF n/a Refrigerant Type R41 OA Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc,. SPEC I • MUC60NA Model nuynber Outdoor unit MXZ-8C60NA In ••• • • • Ducted Charge Lbs,oz 11 lbs,4 oz Indoor unit connection Maximum Number of Connected IDU 8(6*A) Minimum Number of Connected.IDU 2 Maximum connected capacity Btu/h 78,000 Minimum connected capacity Btu/h 12,000 Piping Gas Pipe Size O.D. (Flared). In.[mm] 3/4[19.05] Liquid Pipe Size O.D. (Flared) In,[mm] 3/8_[9.52] Total Piping.Length Ft. [m]. 492[150] Maximum Height Difference*e;ODU above Ft. [m] 164[50] IDU Maximum Height Difference*e, 0DU below Ft. [m]. . 131 [40] IDU Maximum Height Difference*B, between Ft. [m] 49[15] branch boxes Max. Piping Length between ODU and Ft.:[m] 180 [55] Branch_Box Farthest Piping Length from ODU to IDU Ft. [m] 262[80] Farthest Piping Length after-Branch Box Ft. [m] 82[25] Total Piping Length.between Branch Boxes Ft. [m] . 311 [95] and IDU Maximum Number of Bends 15 AHRI Rated *1 Cooling (Indoor H Outdoor). OF 80°F DB,670F WB H 95°F DB, 75°F WB Conditions(Rated data is determined *2 Heating at 470_F(Indoor H Outdoor) OF 70OF DB, 60°F WB H 47°F DB,43°F WB at fixed *3 Heating at 17°F(Indoor://Outdoor) °F 70°F:DB, 60*F WB H 17°F DB,.15°F WB compressor speed) Conditions *4 Heating at 50F.(I.9door H Outdoor). OF 70°F DB,60-F.WB H-4°F.DB,-5°F WB Notes *5*F DB- 115°F DB when optional wind baffles are installed *A when 1 or more PLA-A•EA7 connected *B Branch box should be placed within the level between the outdoor unit and indoor units. For reference to connected capacity charts, please refer MXZ-8C60NA Operational Performance. Specifications are subject to change without notice. Copyright C)2017 Mitsubishi•Electric US,Inc. ACCESSORIES: 61 Distribution Pipe for Flare Connection (necessary for installing two branch boxes) ❑ MSDD-50AR-E . . Distribution Pipe for Brazed Connection (necessary for installing two branch boxes) ❑ MSDD-50BR-E Joint Pipe Unit cp9:52—► Pipecp15.88 ❑ PAC-SG76RJ-E Unit cp6.35—► PipeT9.52 ❑ PAC-493PI Unit cp9.52—+ Pipecp12.7 ❑ MAC-A454JP-E Unit cp12.7- Pipe99.52 ❑ MAC-A455JP-E Unit(pl2.7-► Pipecpl5.88 ❑ MAC-A456JP-E Unit cpl5.88--.Pipecp19.05 ❑ PAC-SG75RJ-E Branch Box Three-port Branch Box ❑ PAC-MKA31 BC Five-port Branch Box ❑ PAC-MKA51 BC Air Discharge Guide ❑ PAC=SH96SG-E Drain Socket ❑ PAC-SG61 DS-E Base Pan Heater ❑PAC-SJ20BH-E Centralized Drain Pan ❑ PAC-SH97DP-E. Control Cable ❑CW162S 3-pole Disconnect ❑TAZ-MS303 Wall Mounting Bracket(Powder-coated Steel) ❑ QCWB2000M-1 Wall Mounting Bracket(316 Series Stainless Steel) ❑ QCWBSS Outdoor Unit Mounting Pad 24"x 42"x 3" ❑ ULTRILITE2 MiniSplit Mounting Stand-Dual Fan models- 12" ❑QSMS1202M MiniSplit Mounting Stand-Dual Fan models- 18" ❑QSMS1802M MiniSplit Mounting Stand-Dual Fan models-24" ❑ QSMS2402M Diamondback 1/4 x 1/2 x 15'/1/2"Lineset(Twin-Tube Insulation) o MLS141212T 15 Linesets'1 --- - - --- 1/4 x 1/2 x 30 /1/2 Lineset(Twin-Tube Insulation) ❑ MLS141212T-'30 1/4 x 1/2 x 50'/1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T 50 1/4 x 1/2 x 65'/1/2"Lineset(Twin-Tube Insulation) ❑MLS141212T 65 1/4 x 1/2 x 100'/1/2" Lineset(Twin-Tube Insulation) ❑ MLS141212T-100 3/8 x 5/8 x 10'/1/2" Lineset(Twin-Tube Insulation) ❑MPLS38581ZT-10 3/8 x 5/8 x 15'/1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T 15 3/8 x 5/8 x 30'/1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T.30 3/8 x 5/8 x 50'/1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812T-50 3/8 x 5/8 x 65'/ 1/2" Lineset(Twin-Tube Insulation) ❑ MPLS385812Tm65 3/8 x 5/8 x 100'/1/2"Lineset(Twin-Tube Insulation) ❑MPLS385812T-100 Linesels are indoor unit specific and will be listed In the IDU information-the Joint Pipe adaptors are used in this application Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. MXZ-8C60NA SYSTEM DESIGN Outdoor unit MXZ-4C36NAHZ(-U1) MXZ-5C42NAHZ(-U1)' MXZ-88C48NA(-Ul) MXZ-8C60NA-U1 - -MXZ-8C48NA-U1) 4HP 4.5HP 5HP .7HP Rated capacityl Cooling 36 42 48 60 (kBTU/h) I Heating 45 48 54 66 Refrigerant R410A Connectable Capacity Type 06 to Type 36 indoor unit Caution: The indoor unit which rated capacity exceeds 36 kBTU/.h(Type 36).can NOT be connected. Number of units 2(*1)to 4 units 2(*1)to'5'units 2(*l)to B units 2(*1)to 8 units Total system-wide capacity 33 to 130%of outdoor 29 to 130%of outdoor 25 to 130%of outdoor .20 to 130%of outdoor unit capacity unit capacity unit capacity_ unit capacity (12 to 46.8 kBTU/h) (12 to 54.6 kBTU/h) (12 to 62.4 kBTU/h) (12 to 78 kBTU/h) Connectable Number of units branch box 1 or.2 units Connectable indoor unit lineups(Heat pump inverter type)' Model type Model name Capacity class[kBTU/h] 06 09 12 1 15 1 18 1 24 1 30 36 Wall Deluxe MSZ-FE09/12118NA mounted MSZ-FH06/09/12/15NA,18NA2 Designer 1V1SZ-EF09/12/15/18NA(W/B/S) Standard MSZ-GE06/09/12/15/18/24NA MSZ-GL06/09/12/15/.18/24NA Ceiling .Low static pressure*3 SEZ-KD09/12/15/18NA concealed .Middle static pressure*3 PEAD-A24/30/36AA5 0 . . 40 0. 4-way ceiling 12 by 2 type SLZ-KA09/12/15NA .0 cassette Standard PLA-Al2/18/24/30/36BA6 0 0 . PLA-Al2/18/24/30/36EA7* Floor standing MFZ-KA09/1.2/18NA MFZ-KJ09/12/15/18NA Multi-position*2 MVZ-Al2/18/24/30/36AA4 Branch box PAC4KA5013C .PAC-MKA51 BC PAC-MKA30BC PAC-MKA31 BC Number of branches 5 branches 3 branches (Indoor unit that can be connected) (MAX.5 units) (MAX.3 units) Note:A maximum of 2 branch boxes can be connected to 1 outdoor unit. 2-branch pipe(joint):Optional parts In case of using 1-branch box No need In case of using 2-branch boxes Model name Connection method MSDD-50AR-E Iflare Select a model according to the connection method. MSDD-50BR-E lbrazing Option I Optional accessories for indoor units and outdoor units are available. *1 1 for MVZ model.Single unit connection is possible with MVZ-series unit. *2 When connecting a multi-position unit(s),set additional constraints as follows.For connections other than those specified below,consult yourdealer. • Models other than MXZ-8C60NA •MXZ-8C60NA(For each connected branch box) Number of connecting Number of connecting multi-position unit Constraints multi-position unit Constraints 2 Any indoor units other than multi-position models 2 Any indoor units other than multi-position are not connectable. models are not connectable. 1 None The total system wide capacity should be 100% (Only the ordinal constraints apply.) 1 or below including the MVZ-series unit. Only 1 SEZ or,1'PEAD can be included in the connection. *3 For MXZ-8C60NA;When connecting the SEZ and PEAD-series units,the total system wide capacity.per 1 branch.box should be 100%or below including the SEZ and PEAD-series units.(Only if connecting to PAC=MKA50/51 BC) *4 When the system includes even 1 unit of PLA-A•EA7,the number of the maximum connectable indoor units.is decreased as follows: 3 for MXZ-4C36NAHZ-U1,4 for MXZ-5C42NAHZ-Uf,and 6 for MXZ-8C48NA(HZ)-U1 and MXZ-8C60NA-U1 Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US,Inc. MXZ-8C60NA SYSTEM DESIGN Piping connection size ..A B: �3/8:inch The piping connection size differs according to the type and capacity of indoor units. Liquid Match the-pipingconnection size of branch box with indoor unit. [9.52 mm] If the piping connection size of branch box does not match the piping connection size of Gas 05/8 inch 03/4 inch* .indoor unit,use-optional different-diameter(deformed)joints to the branch box side. [15.88 mm] [19.05 mm] (Connect deformed joint directly to the branch box side.) *MXZ,8CWNA only Flare�connection employed..(No brazing!). ■.In case of.using 1=branch box Flare connection employed (No brazing) A /.Branch box � B B B B B ■ In case of using 2-branch boxes 2 branches pipe (joint), optional parts A A Branch-box#1 A IB B B B B .Branch box#2 ■Installation procedure(2 branches pipe.(joint)) Refer to the installation manuals of MSDD-SOAR-E and MSDD-50BR-E. Specifications are subject to change without notice. Copyright 0 2017 Mitsubishi:Electric US,Inc. DIMENSIONS: BC AND i BRANCH PAC-MKA51BC Unit: mm'<inch> When Installing the conduit. Set the attachment to the inner side of each panel. se(2-9nz> SUSPENSION BOLTPRLH 22pp yy 320(12.19132) (2Sg2) (1-3112) �m SUSPENSION BOLT:W3/8(M10) a o ' REFRIGERANT PIPE FLARED CONNECTION Unit:inch A 13 C 1 D I E I TO OUTDOOR UNIT V120'.) LIQUID PIPE 1/4F 114E 1/4F 1/4F 114E 3/8F5.4zz(ne)GAS PIPE 318E 3/8F 3/8F 3/8F 112E 5/8FWIE �.. .. t1J—.. .. 90 TERMINAL BLOCK " 450(17-2332) (347/32) (325132) 280(11-11J2) 40(1.17132) TOM-NETUNrT 67(2-8/18) 72 07 B7 70 TERMINALBLOCK 6' TO INDOOR UNIT (2-27132) (19172) (3-7116) (2.3/4) &ELECTRIC WIRE INLET TO INDOOR UNIT ffl2215 C B B A A OOI 15 25 CONTROL COVER TERMNAL BLOCK 1 1CNDORPATETOOTDOOR UNR(]Y4) (2210 TOOUTOOORUNIT SERVICE PANEL (for LEV,THERMISTOR) PAC-MKA31 BC SUSPENSION BOLT PITCH When installing the Conduit. 320 e2.1902) Set the attachment to the inner side of each panel. 58(2.9132) 20 28 (25132) (/-3l32) �a SUSPENSION BOLT:W3/8(M10) m o REFRIGERANT PIPE FLARED CONNECTION Unit:inch A 1B iC 1 TO OUTDOORqLj� «a v a LIQUID PIPE ji 114E 114E 1 1/4F li I 3/8F GAS PIPEI 3/8F I 3/8F I 3/8F 5/8F 5-022(7/8> na etl dun 1200 eNmoCooto 15(1913?) 66(2-19732) ry 1:2 45007-2Y32) (3-17132) 96 " 209(8.7/32) (2-271,32> (3-25132) 280(11-1132) 40(1-17132) TERMINAL BLOCK TO M-NET UNIT AP TOINDOOR UNR (39tl2) (3.7%6) (2204) 5-ELECTRIC WIRE WLET TERMINAL BLOCK TOINDOORUNR n � �d Yak C C B B A A a ®® ® Al EEr • 70 CP 25 25 25 CONTftOLCOVER TERMINAL BLOCK 1 1) 1) TOOUiD00R UNR TOOUTOOORUNIT SERV ICE PANEL CONDOR PLATE (2314) (t Y4) (Tor LEV,THERMISTOR) Specifications are subject to change without.notice'. Copyright©-2017'Mitsubishi Electric US,Inc.